Sample records for air samples obtained

  1. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-104 at the Conclusion of 7A

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-l04 (7 A) flight to the ISS is reported. ISS air samples were taken in June and July 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Atlantis using GSCs. Solid sorbent air sampler (SSAS) samples were obtained from the ISS in April, June, and July. Analytical methods have not changed from earlier reports, and all quality control measures were met.

  2. Isokinetic air sampler

    DOEpatents

    Sehmel, George A.

    1979-01-01

    An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.

  3. Automatic electrochemical ambient air monitor for chloride and chlorine

    DOEpatents

    Mueller, Theodore R.

    1976-07-13

    An electrochemical monitoring system has been provided for determining chloride and chlorine in air at levels of from about 10-1000 parts per billion. The chloride is determined by oxidation to chlorine followed by reduction to chloride in a closed system. Chlorine is determined by direct reduction at a platinum electrode in 6 M H.sub.2 SO.sub.4 electrolyte. A fully automated system is utilized to (1) acquire and store a value corresponding to electrolyte-containing impurities, (2) subtract this value from that obtained in the presence of air, (3) generate coulometrically a standard sample of chlorine mixed with air sample, and determine it as chlorine and/or chloride, and (4) calculate, display, and store for permanent record the ratio of the signal obtained from the air sample and that obtained with the standard.

  4. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0006

    NASA Technical Reports Server (NTRS)

    Gauntner, D. J.; Holdeman, J. D.; Humenik, F. M.

    1977-01-01

    The NASA Global Atmospheric Sampling Program (GASP) is obtaining measurements of atmospheric trace constituents in the upper troposphere and lower stratosphere using fully automated air sampling systems on board several commercial B-747 aircraft in routine airline service. Atmospheric ozone, and related flight and meteorological data were obtained during 245 flights of a Qantas Airways of Australia B-747 and two Pan American World Airways B-747s from July 1976 through September 1976. In addition, whole air samples, obtained during three flights, were analyzed for trichlorofluoromethane, and filter samples, obtained during four flights, were analyzed for sulfates, nitrates, fluorides, and chlorides. Flight routes and dates, instrumentation, data processing procedures, data tape specifications, and selected analyses are discussed.

  5. Commander De Winne poses for a photo during Air Sampling

    NASA Image and Video Library

    2009-11-11

    ISS021-E-024700 (11 Nov. 2009) --- European Space Agency astronaut Frank De Winne, Expedition 21 commander, uses the Microbial Air Sampler kit (floating freely near De Winne) to obtain microbiology (bacterial & fungal) air samples in the Kibo laboratory of the International Space Station.

  6. Air-coupled ultrasound: a novel technique for monitoring the curing of thermosetting matrices.

    PubMed

    Lionetto, Francesca; Tarzia, Antonella; Maffezzoli, Alfonso

    2007-07-01

    A custom-made, air-coupled ultrasonic device was applied to cure monitoring of thick samples (7-10 mm) of unsaturated polyester resin at room temperature. A key point was the optimization of the experimental setup in order to propagate compression waves during the overall curing reaction by suitable placement of the noncontact transducers, placed on the same side of the test material, in the so-called pitch-catch configuration. The progress of polymerization was monitored through the variation of the time of flight of the propagating longitudinal waves. The exothermic character of the polymerization was taken into account by correcting the measured value of time of flight with that one in air, obtained by sampling the air velocity during the experiment. The air-coupled ultrasonic results were compared with those obtained from conventional contact ultrasonic measurements. The good agreement between the air-coupled ultrasonic results and those obtained by the rheological analysis demonstrated the reliability of air-coupled ultrasound in monitoring the changes of viscoelastic properties at gelation and vitrification. The position of the transducers on the same side of the sample makes this technique suitable for on-line cure monitoring during several composite manufacturing technologies.

  7. SOURCES OF PCBS TO THE ATMOSPHERE IN CHICAGO

    EPA Science Inventory

    The project will obtain additional short-term PCB samples in southwestern Chicago to determine the amount of PCB emissions to the air from a sludge drying facility. Four different types of samples will be collected: (1) short-term ambient air samples surrounding the drying beds,...

  8. Mercury Vacuum Cleaner, Operational Test and Evaluation

    DTIC Science & Technology

    1981-03-01

    Indirect readings were obtained by air sampling with hopcalite tubes and subsequent analysis by the USAF OEHL Analytical Services Division. - r...during the operational and storage modes of the MRS-3 vacuum. During the operational mode, indirect ( hopcalite ) air sampling was periodically taken at...from the top and bottom sides of the HEPA and charcoal filter. During the storage mode, indirect ( hopcalite and dosimeter coil) air sampling was

  9. Aircraft data summaries for the SURE intensives. Final report. [Data obtained during January/February 1978 near Duncan Falls, Ohio and Lewisburg, Virginia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keifer, W.S.; Blumenthal, D.L.; Tommerdahl, J.B.

    1981-09-01

    As part of the EPRI sulfate regional experiment (SURE), Meteorology Research, Inc., (MRI) and Research Triangle Institute (RTI) conducted six air quality sampling programs in the eastern United States using instrumented aircraft. This volume includes the air quality and meteorological data obtained during the January/February 1978 Intensive when MRI sampled near the Duncan Falls, Ohio, SURE Station and RTI sampled near the Lewisburg, Virginia, SURE Station. Sampling data are presented for all measured parameters.

  10. Measuring the radon concentration in air meting van de radonconcentratie in lucht

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aten, J.B.T.; Bierhuizen, H.W.J.; Vanhoek, L.P.

    1975-01-01

    A simple transportable apparatus for measurement of the radon concentration in the air of a workshop was developed. An air sample is sucked through a filter and the decay curve of the alpha activity is measured. The counting speed 40 min after sampling gives an indication of the radon activity. The apparatus was calibrated by analyzing an analogous decay curve obtained with a big filter and a big air sample, the activity being measured with an anti-coincidence counter. (GRA)

  11. Composition Alteration of Stratospheric Air Due to Sampling through a Flow Tube.

    DTIC Science & Technology

    1984-02-03

    C. C. , Forsberg, C. A. , and Pieri , H. V. (19)83) Stratospheric N 20 CF2 Cl and CFCI3 composition studies utilizing in situ cryogenic whole air...Gas-Surface Interactions in Cryogenic Whole Air Sampling, AFGL-TR-81-0162, AD A108255. 19. Gallagher, C. C., Forsberg, C. A., and Pieri , R. V. (1983...Gallagher, C. C., Forsberg, C. A., Pieri , R. V., and Faucher, G. A. (1983a) Oxides of Nitrogen Content of Whole Air Samples Obtained at Altitudes From 12

  12. Comparison of the Results of Studies of Air Pollution Fungi Using the SAS Super 100, MAS 100, and Air IDEAL.

    PubMed

    Łukaszuk, Cecylia; Krajewska-Kułak, Elżbieta; Guzowski, Andrzej; Kułak, Wojciech; Kraszyńska, Bogumiła

    2017-07-20

    Although several air sampling devices for identifying and enumerating airborne microorganisms are commercially available, each poses some limitations. The aim of this study was to evaluate air pollution fungi using three such samplers: SAS Super 100, Microbiological Air Sampler (MAS) 100, and Air IDEAL. Mycological air was taken from the cellars of a 17th-century church in Siemiatycze, Poland, and the nearby outdoor environment. With samplers placed 1.5 m above the floor, microbial flora in air samples collected inside and outside the cellar were detected. The number of colony-forming units (CFU) of fungi obtained with the three samplers from the cellars and outdoor environment differed; the most CFU were obtained with the Air IDEAL and the least with the SAS Super 100. Significant differences emerged in CFUs collected from air samples with the MAS 100 and SAS Super 100, on the one hand, and the SAS Super 100 and Air IDEAL, on the other. Otherwise, results among the samplers were different. More Cladosporium species were collected with the MAS 100 sampler, whereas more Fusarium and Aspergillus species were collected with the Air IDEAL sampler. Significant differences among CFU/m³ values among the tested sites depended on the sampler used.

  13. Comparison of indoor air sampling and dust collection methods for fungal exposure assessment using quantitative PCR.

    PubMed

    Cox, Jennie; Indugula, Reshmi; Vesper, Stephen; Zhu, Zheng; Jandarov, Roman; Reponen, Tiina

    2017-10-18

    Evaluating fungal contamination indoors is complicated because of the many different sampling methods utilized. In this study, fungal contamination was evaluated using five sampling methods and four matrices for results. The five sampling methods were a 48 hour indoor air sample collected with a Button™ inhalable aerosol sampler and four types of dust samples: a vacuumed floor dust sample, newly settled dust collected for four weeks onto two types of electrostatic dust cloths (EDCs) in trays, and a wipe sample of dust from above floor surfaces. The samples were obtained in the bedrooms of asthmatic children (n = 14). Quantitative polymerase chain reaction (qPCR) was used to analyze the dust and air samples for the 36 fungal species that make up the Environmental Relative Moldiness Index (ERMI). The results from the samples were compared by four matrices: total concentration of fungal cells, concentration of fungal species associated with indoor environments, concentration of fungal species associated with outdoor environments, and ERMI values (or ERMI-like values for air samples). The ERMI values for the dust samples and the ERMI-like values for the 48 hour air samples were not significantly different. The total cell concentrations of the 36 species obtained with the four dust collection methods correlated significantly (r = 0.64-0.79, p < 0.05), with the exception of the vacuumed floor dust and newly settled dust. In addition, fungal cell concentrations of indoor associated species correlated well between all four dust sampling methods (r = 0.68-0.86, p < 0.01). No correlation was found between the fungal concentrations in the air and dust samples primarily because of differences in concentrations of Cladosporium cladosporioides Type 1 and Epicoccum nigrum. A representative type of dust sample and a 48 hour air sample might both provide useful information about fungal exposures.

  14. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24 hours of... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... the dilute exhaust and dilution air sample collection systems. (4) For methanol-fueled vehicles, with...

  15. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24 hours of... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... the dilute exhaust and dilution air sample collection systems. (4) For methanol-fueled vehicles, with...

  16. COMPARISON OF 24H AVERAGE VOC MONITORING RESULTS FOR RESIDENTIAL INDOOR AND OUTDOOR AIR USING CARBOPACK X-FILLED DIFFUSIVE SAMPLERS AND ACTIVE SAMPLING - A PILOT STUDY

    EPA Science Inventory

    Analytical results obtained by thermal desorption GC/MS for 24h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive samp...

  17. Three field tests of a gas filter correlation radiometer

    NASA Technical Reports Server (NTRS)

    Campbell, S. A.; Casas, J. C.; Condon, E. P.

    1977-01-01

    Test flights to remotely measure nonurban carbon monoxide (CO) concentrations by gas filter correlation radiometry are discussed. The inferred CO concentrations obtained through use of the Gas Filter Correlation Radiometer (GFCR) agreed with independent measurements obtained by gas chromatography air sample bottle analysis to within 20 percent. The equipment flown on board the aircraft, the flight test procedure, the gas chromatograph direct air sampling procedure, and the GFCR data analysis procedure are reported.

  18. Sampling and Analyzing Air Pollution: An Apparatus Suitable for Use in Schools.

    ERIC Educational Resources Information Center

    Rockwell, Dean M.; Hansen, Tony

    1994-01-01

    Describes two variations of an air sampler and analyzer that are inexpensive to construct, easy to operate, and designed to be used in an educational program. Variations use vacuum cleaners and aquarium pumps, and white facial tissues serve as filters. Samples of air pollution obtained by this method may be used from early grade school to advanced…

  19. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-105 at the Conclusion of 7A.1

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-105 (7 A.1) flight to the ISS is reported. ISS air samples were taken in August 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and surrogate standard recoveries were 64-115%. Pressure tracking indicated no leaks in the canisters.

  20. Simple and accurate quantification of BTEX in ambient air by SPME and GC-MS.

    PubMed

    Baimatova, Nassiba; Kenessov, Bulat; Koziel, Jacek A; Carlsen, Lars; Bektassov, Marat; Demyanenko, Olga P

    2016-07-01

    Benzene, toluene, ethylbenzene and xylenes (BTEX) comprise one of the most ubiquitous and hazardous groups of ambient air pollutants of concern. Application of standard analytical methods for quantification of BTEX is limited by the complexity of sampling and sample preparation equipment, and budget requirements. Methods based on SPME represent simpler alternative, but still require complex calibration procedures. The objective of this research was to develop a simpler, low-budget, and accurate method for quantification of BTEX in ambient air based on SPME and GC-MS. Standard 20-mL headspace vials were used for field air sampling and calibration. To avoid challenges with obtaining and working with 'zero' air, slope factors of external standard calibration were determined using standard addition and inherently polluted lab air. For polydimethylsiloxane (PDMS) fiber, differences between the slope factors of calibration plots obtained using lab and outdoor air were below 14%. PDMS fiber provided higher precision during calibration while the use of Carboxen/PDMS fiber resulted in lower detection limits for benzene and toluene. To provide sufficient accuracy, the use of 20mL vials requires triplicate sampling and analysis. The method was successfully applied for analysis of 108 ambient air samples from Almaty, Kazakhstan. Average concentrations of benzene, toluene, ethylbenzene and o-xylene were 53, 57, 11 and 14µgm(-3), respectively. The developed method can be modified for further quantification of a wider range of volatile organic compounds in air. In addition, the new method is amenable to automation. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. 3-D Surface Depression Profiling Using High Frequency Focused Air-Coupled Ultrasonic Pulses

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Kautz, Harold E.; Abel, Phillip B.; Whalen, Mike F.; Hendricks, J. Lynne; Bodis, James R.

    1999-01-01

    Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. This article shows quantitative surface topography profiles as obtained using only high-frequency focused air-coupled ultrasonic pulses. The profiles were obtained using a profiling system developed by NASA Glenn Research Center and Sonix, Inc (via a formal cooperative agreement). (The air transducers are available as off-the-shelf items from several companies.) The method is simple and reproducible because it relies mainly on knowledge and constancy of the sound velocity through the air. The air transducer is scanned across the surface and sends pulses to the sample surface where they are reflected back from the surface along the same path as the incident wave. Time-of-flight images of the sample surface are acquired and converted to depth/surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in air (V). The system has the ability to resolve surface depression variations as small as 25 microns, is useable over a 1.4 mm vertical depth range, and can profile large areas only limited by the scan limits of the particular ultrasonic system. (Best-case depth resolution is 0.25 microns which may be achievable with improved isolation from vibration and air currents.) The method using an optimized configuration is reasonably rapid and has all quantitative analysis facilities on-line including 2-D and 3-D visualization capability, extreme value filtering (for faulty data), and leveling capability. Air-coupled surface profilometry is applicable to plate-like and curved samples. In this article, results are shown for several proof-of-concept samples, plastic samples burned in microgravity on the STS-54 space shuttle mission, and a partially-coated cylindrical ceramic composite sample. Impressive results were obtained for all samples when compared with diamond-tip profiles and measurements from micrometers. The method is completely nondestructive, noninvasive, non-contact and does not require light-reflective surfaces.

  2. An analysis of using semi-permeable membrane devices to assess persistent organic pollutants in ambient air of Alaska

    NASA Astrophysics Data System (ADS)

    Wu, Ted Hsin-Yeh

    A region of concern for persistent organic pollutants (POPS) contamination is the Arctic, because of POPs' ability to migrate long distances through the atmosphere toward cold regions, condense out of the atmosphere in those region, deposit in sensitive arctic ecosystems and bioaccumulate in Arctic species. Thus, monitoring of POP concentrations in the Arctic is necessary. However, traditional active air monitoring techniques for POPs may not be feasible in the Arctic, because of logistics and cost. While these issues may be overcome using passive air sampling devices, questions arise about the interpretation of the contaminant concentrations detected using the passive air samplers. In this dissertation semi-permeable membrane devices (SPMDs) containing triolein were characterized and evaluated for use in sampling the ambient air of Alaska for three classes of POPS (organochlorines [OCs], polychlorinated biphenyls [PCBs] and polyaromatic hydrocarbons [PAHs]). In addition, a SPMD-based sampling campaign for POPS was conducted simultaneously at five sites in Alaska during a one-year period. The POP concentrations obtained from the SPMDs were examined to determine the spatial and seasonal variability at the locations. POP concentrations detected in SPMDs were influenced by exposure to sunlight, concentrations of particulate-bound contaminants and changes in temperature. PAH concentrations in a SPMD mounted in a sunlight-blocking deployment unit were higher than in a SPMD exposed to sunlight (P = 0.007). PCB concentrations in SPMD exposed to filtered and non-filtered air were significantly different (P < 0.0001). Derived PAH air concentrations measured using SPMD were within a factor of approximately 7 of those obtained from an air sampler in Barrow, Alaska. The field study showed three distinct groups of samples. Barrow was separated from the sub-Arctic samples and a Homer sample (September-December) was distinct from the sub-Arctic samples. The separations suggest different air masses are being sampled by SPMDs. Lower concentrations of total POPs were measured at the coastal sites than the Interior sites.

  3. Vapor concentration monitor

    DOEpatents

    Bayly, John G.; Booth, Ronald J.

    1977-01-01

    An apparatus for monitoring the concentration of a vapor, such as heavy water, having at least one narrow bandwidth in its absorption spectrum, in a sample gas such as air. The air is drawn into a chamber in which the vapor content is measured by means of its radiation absorption spectrum. High sensitivity is obtained by modulating the wavelength at a relatively high frequency without changing its optical path, while high stability against zero drift is obtained by the low frequency interchange of the sample gas to be monitored and of a reference sample. The variable HDO background due to natural humidity is automatically corrected.

  4. Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.

    PubMed

    Smith, Philip A; Simmons, Michael K; Toone, Phillip

    2018-06-01

    It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.

  5. Mapping Air Quality Index of Carbon Monoxide (CO) in Medan City

    NASA Astrophysics Data System (ADS)

    Suryati, I.; Khair, H.

    2017-03-01

    This study aims to map and analyze air quality index of carbon monoxide (CO) in Medan City. This research used 12 (twelve) sampling points around in Medan with an hour duration each point. CO concentration was analyzed using the NDIR CO Analyzer sampling tool. The concentration CO was obtained between 1 ppm - 23 ppm, with an average concentration was 9.5 ppm. This condition is still below the national ambient air quality standard set by Government Regulation of Indonesian Republic Number 41-1999 amounted to 29 ppm. The result of CO concentration measurements was converted into air pollutant standard index, obtained the index value of 58 - 204. Surfer 10 was used to create map of air pollutant standard index for CO. The map illustrates very unhealthy area where located in the Medan Belawan district. The main factors affecting the concentration of CO are from transportation and meteorological factors.

  6. Retrieved Products from Simulated Hyperspectral Observations of a Hurricane

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis C.; Iredell, Lena; Blaisdell, John; Pagano, Thomas; Mathews, William

    2015-01-01

    This research uses GCM derived products, with 1 km spatial resolution and sampled every 10 minutes, over a moving area following the track of a simulated severe Atlantic storm. Model products were aggregated over sounder footprints corresponding to 13 km in LEO, 2 km in LEO, and 5 km in GEO sampled every 72 minutes. We simulated radiances for instruments with AIRS-like spectral coverage, spectral resolution, and channel noise, using these aggregated products as the truth, and analyzed them using a slightly modified version of the operational AIRS Version-6 retrieval algorithm. Accuracy of retrievals obtained using simulated AIRS radiances with a 13 km footprint was similar to that obtained using real AIRS data. Spatial coverage and accuracy of retrievals are shown for all three sounding scenarios. The research demonstrates the potential significance of flying Advanced AIRS-like instruments on future LEO and GEO missions.

  7. Aircraft data summaries for the SURE intensives. Final report. [Sampling done August 1977 near Rockport, Indiana and Duncan Falls, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blumenthal, D.L.; Tommerdahl, J.B.; McDonald, J.A.

    1981-09-01

    As part of the EPRI sulfate regional experiment (SURE), Meteorology Research, Inc., (MRI) and Research Triangle Institute (RTI) conducted six air quality sampling programs in the eastern United States using instrumented aircraft. This volume includes the air quality and meteorological data obtained during the August 1977 Intensive when MRI sampled near the Rockport, Indiana, SURE Station and RTI sampled near the Duncan Falls, Ohio, SURE Station. Sampling data are presented for all measured parameters.

  8. Spectral fingerprinting of polycyclic aromatic hydrocarbons in high-volume ambient air samples by constant energy synchronous luminescence spectroscopy

    USGS Publications Warehouse

    Kerkhoff, M.J.; Lee, T.M.; Allen, E.R.; Lundgren, D.A.; Winefordner, J.D.

    1985-01-01

    A high-volume sampler fitted with a glass-fiber filter and backed by polyurethane foam (PUF) was employed to collect airborne particulate and gas-phase polycylic aromatic hydrocarbons (PAHs) in ambient air. Samples were collected from four sources representing a range of environmental conditions: gasoline engine exhaust, diesel engine exhaust, air near a heavily traveled interstate site, and air from a moderately polluted urban site. Spectral fingerprints of the unseparated particulate and gas-phase samples were obtained by constant energy synchronous luminescence spectroscopy (CESLS). Five major PAHs in the gas-phase extracts were characterized and estimated. The compatibility of a high-volume sampling method using polyurethane foam coupled with CESLS detection is explored for use as a screening technique for PAHs in ambient air. ?? 1985 American Chemical Society.

  9. Assessment of air quality in Haora River basin using fuzzy multiple-attribute decision making techniques.

    PubMed

    Singh, Ajit Pratap; Chakrabarti, Sumanta; Kumar, Sumit; Singh, Anjaney

    2017-08-01

    This paper deals with assessment of air quality in Haora River basin using two techniques. Initially, air quality indices were evaluated using a modified EPA method. The indices were also evaluated using a fuzzy comprehensive assessment (FCA) method. The results obtained from the fuzzy comprehensive assessment method were compared to that obtained from the modified EPA method. To illustrate the applicability of the methodology proposed herein, a case study has been presented. Air samples have been collected at 10 sampling sites located along Haora River. Six important air pollutants, namely, carbon monoxide, sulfur dioxide, nitrogen dioxide, suspended particulate matter (SPM), PM 10 , and lead, were monitored continuously, and air quality maps were generated on the GIS platform. Comparison of the methodologies has clearly highlighted superiority and robustness of the fuzzy comprehensive assessment method in determining air quality indices under study. It has effectively addressed the inherent uncertainties involved in the evaluation, modeling, and interpretation of sampling data, which was beyond the scope of the traditional weighted approaches employed otherwise. The FCA method is robust and prepares a credible platform of air quality evaluation and identification, in face of the uncertainties that remain eclipsed in the traditional approaches like the modified EPA method. The insights gained through the present study are believed to be of pivotal significance in guiding the development and implementation of effective environmental remedial action plans in the study area.

  10. Aircraft data summaries for the SURE intensives. Final report. [Sampling done July 1978 near Duncan Falls, Ohio and Scranton, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keifer, W.S.; Blumenthal, D.L.; Tommerdahl, J.B.

    1981-09-01

    As part of the EPRI sulfate regional experiment (SURE), Meteorology Research, Inc., (MRI) and Research Triangle Institute (RTI) conducted six air quality sampling programs in the eastern United States using instrumented aircraft. This volume includes the air quality and meteorological data obtained during the July 1978 Intensive when MRI sampled near the Duncan Falls, Ohio, SURE Station and RTI sampled near the Scranton, Pennsylvania, SURE Station. During the last part of the July 1978 sampling period, both MRI and RTI aircraft participated in a large regional-scale sampling program with Brookhaven National Laboratory (BNL) and Pacific Northwest Laboratory (PNL). Only themore » data obtained by the MRI and RTI aircraft during this regional-scale sapling program are included in this volume.« less

  11. Air Pollution Potential from Electroplating Operations.

    ERIC Educational Resources Information Center

    Diamond, Philip

    Measurements were made of emission rates from electroplating operations considered to have maximum air pollution potential. Sampling was performed at McClellan and additional data from a previous survey at Hill Air Force Base was used. Values obtained were extremely low. Based on existing Federal standards, no collectors are specifically required…

  12. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings

    PubMed Central

    Beamer, P.I.; Sugeng, A. J.; Kelly, M.D.; Lothrop, N.; Klimecki, W.; Wilkinson, S.T.; Loh, M.

    2014-01-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p<0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites. PMID:24469149

  13. Plasma-surface modification vs air oxidation on carbon obtained from peach stone: Textural and chemical changes and the efficiency as adsorbents

    NASA Astrophysics Data System (ADS)

    De Velasco Maldonado, Paola S.; Hernández-Montoya, Virginia; Montes-Morán, Miguel A.

    2016-10-01

    Carbons were prepared from peach stones (Prunus persica) using different carbonization temperatures (600, 800 and 1000 °C). A selected sample was modified by oxidation using conventional oxidation techniques (thermal treatment in air atmosphere) and with cold oxygen plasma oxidation, under different conditions. Samples were characterized using elemental analysis, FT-IR spectroscopy, nitrogen adsorption isotherms at -196 °C, SEM/EDX analysis, potentiometric titration and XPS analysis. Carbons with and without oxidation were employed in the adsorption of Pb2+ in aqueous solution. Results obtained indicated that the materials with high contents of acidic oxygen groups were more efficient in the removal of Pb2+, values as high as approx. 40 mg g-1 being obtained for the best performing carbon. Textural properties of the original, un-oxidized carbon were significantly altered only after oxidation under air atmosphere at 450 °C. On the other hand, the samples oxidized with plasma show little changes in the textural parameters and a slight increase in the specific surface was observed for the sample treated at high RF power (100 W). Additionally, a significant increment of the oxygen content was observed for the plasma oxidized samples, as measured by XPS.

  14. Aircraft data summaries for the SURE intensives. Final report. [Sampling done October, 1978 near Duncan Falls, Ohio and Giles County, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keifer, W.S.; Blumenthal, D.L.; Tommerdahl, J.B.

    1981-09-01

    As part of the EPRI sulfate regional experiment (SURE), Meteorology Research, Inc., (MRI) and Research Triangle Institute (RTI) conducted six air quality sampling programs in the eastern United States using instrumented aircraft. This volume includes the air quality and meteorological data obtained during the October 1978 intensive when MRI sampled near the Giles County, Tennessee, SURE Station and RTI sampled near the Duncan Falls, Ohio, SURE Station. Sampling data are presented for all measured parameters.

  15. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-102 at the Conclusion of 5A.1

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-102 (5A.1) flight to the ISS is reported. ISS air samples were taken in late February 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges . A "first-entry" sample of the multipurpose logistics module (MPLM) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 contribution). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample. Formaldehyde is quantified separately.

  16. Atomic resolution images of graphite in air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grigg, D.A.; Shedd, G.M.; Griffis, D.

    One sample used for proof of operation for atomic resolution in STM is highly oriented pyrolytic graphite (HOPG). This sample has been imaged with many different STM`s obtaining similar results. Atomic resolution images of HOPG have now been obtained using an STM designed and built at the Precision Engineering Center. This paper discusses the theoretical predictions and experimental results obtained in imaging of HOPG.

  17. Shelf life of ready to use peeled shrimps as affected by thymol essential oil and modified atmosphere packaging.

    PubMed

    Mastromatteo, Marianna; Danza, Alessandra; Conte, Amalia; Muratore, Giuseppe; Del Nobile, Matteo Alessandro

    2010-12-15

    In this work the influence of different packaging strategies on the shelf life of ready to use peeled shrimps was investigated. First, the effectiveness of the coating (Coat) and the active coating loaded with different concentrations of thymol (Coat-500, Coat-1000, and Coat-1500) on the quality loss of the investigated food product packaged in air was addressed; afterwards, the thymol concentration that had shown the best performance was used in combination with MAP (5% O(2); 95% CO(2)). Microbial cell load of main spoilage microorganisms, pH and sensorial quality were monitored during the refrigerated storage. Results of the first step suggested that the sole coating did not affect the microbial growth. A slight antimicrobial effect was obtained when the coating was loaded with thymol and a concentration dependence was also observed. Moreover, the active coating was effective in minimizing the sensory quality loss of the investigated product, it was particularly true at the lowest thymol concentration. In the second step, the thymol concentration (1000 ppm) that showed the strike balance between microbial and sensorial quality was chosen in combination with MAP. As expected, MAP significantly affected the growth of the mesophilic bacteria. In particular, a cell load reduction of about 2 log cycle for the samples under MAP respect to that in air was obtained. Moreover, the MAP packaging inhibited the growth of the Pseudomonas spp. and hydrogen sulphide-producing bacteria. The MAP alone was not able to improve the shelf life of the uncoated samples. In fact, no significant difference between the control samples packaged in air and MAP was observed. Whilst, the use of coating under MAP condition prolonged the shelf life of about 6 days with respect to the same samples packaged in air. Moreover, when the MAP was used in combination with thymol, a further shelf life prolongation with respect to the samples packaged in air was observed. In particular, a shelf life of about 14 days for the active coating under MAP compared to the same samples in air (5 days) was obtained. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1974-01-01

    The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

  19. Trace gas measurements from whole air samples collected over the Antarctic continent

    NASA Technical Reports Server (NTRS)

    Heidt, L. E.; Vedder, J. F.; Pollock, Walter H.; Henry, Bruce E.; Lueb, Richard A.

    1988-01-01

    Whole air samples collected aboard the NASA DC-8 and ER-2 aircraft as part of the Airborne Antarctic Ozone Experiment (AAOE) were analyzed in a field laboratory set up at Punta Arenas, Chile, in August and September, 1987. Mixing ratios obtained from gas chromatographic analyses of these samples are presented for N2O, CFCl3, CFCl2, C2F3Cl3, CH3CCl3, CH4, and CO. Variations in the mixing ratios of these gases along the individual flight paths of the aircraft are used as tracers to indicate the history of air masses over and near the Antarctic continent.

  20. Molecular comparison of the sampling efficiency of four types of airborne bacterial samplers.

    PubMed

    Li, Kejun

    2011-11-15

    In the present study, indoor and outdoor air samples were collected using four types of air samplers often used for airborne bacterial sampling. These air samplers included two solid impactors (BioStage and RCS), one liquid impinger (BioSampler), and one filter sampler with two kinds of filters (a gelatin and a cellulose acetate filter). The collected air samples were further processed to analyze the diversity and abundance of culturable bacteria and total bacteria through standard culture techniques, denaturing gradient gel electrophoresis (DGGE) fingerprinting and quantitative polymerase chain reaction (qPCR) analysis. The DGGE analysis indicated that the air samples collected using the BioStage and RCS samplers have higher culturable bacterial diversity, whereas the samples collected using the BioSampler and the cellulose acetate filter sampler have higher total bacterial diversity. To obtain more information on the sampled bacteria, some gel bands were excised and sequenced. In terms of sampling efficiency, results from the qPCR tests indicated that the collected total bacterial concentration was higher in samples collected using the BioSampler and the cellulose acetate filter sampler. In conclusion, the sampling bias and efficiency of four kinds of air sampling systems were compared in the present study and the two solid impactors were concluded to be comparatively efficient for culturable bacterial sampling, whereas the liquid impactor and the cellulose acetate filter sampler were efficient for total bacterial sampling. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Determination of trichloroanisole and trichlorophenol in wineries' ambient air by passive sampling and thermal desorption-gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Camino-Sánchez, F J; Bermúdez-Peinado, R; Zafra-Gómez, A; Ruíz-García, J; Vílchez-Quero, J L

    2015-02-06

    The present paper describes the calibration of selected passive samplers used in the quantitation of trichlorophenol and trichloroanisole in wineries' ambient air, by calculating the corresponding sampling rates. The method is based on passive sampling with sorbent tubes and involves thermal desorption-gas chromatography-triple quadrupole mass spectrometry analysis. Three commercially available sorbents were tested using sampling cartridges with a radial design instead of axial ones. The best results were found for Tenax TA™. Sampling rates (R-values) for the selected sorbents were determined. Passive sampling was also used for accurately determining the amount of compounds present in the air. Adequate correlation coefficients between the mass of the target analytes and exposure time were obtained. The proposed validated method is a useful tool for the early detection of trichloroanisole and its precursor trichlorophenol in wineries' ambient air while avoiding contamination of wine or winery facilities. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

    PubMed

    Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud

    2016-03-01

    Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  3. Combined PIXE and X-ray SEM studies on time-resolved deposits of welding shop aerosols

    NASA Astrophysics Data System (ADS)

    Barfoot, K. M.; Mitchell, I. V.; Verheyen, F.; Babeliowsky, T.

    1981-03-01

    Time-resolved deposits of welding shop air particulates have been obtained using a streak sampling system. PIXE analysis of these deposits, using 2 MeV protons, typically revealed the presence of a large number of elements, with many in the range Z = 11-30. Strong variations, up to three orders of magnitude, in the concentrations of several elements such as Al, Si and Fe as well as Zn, Na, K and Ca were found. The 2 h sampling resolution normally used was found to be insufficient to follow the short pollution episodes that regularly occur in a welding shop environment and so sampling with a 20 min resolution was used. The variation of elemental concentrations for different sampling times together with information on the physical nature of these air particulates, determined with a scanning electron microscope (SEM) and Si(Li) X-ray detector attachment, are presented. This type of information together with that obtained from the PIXE analysis is of importance in industrial hygiene studies. The need to make corrections for partial filter clogging, based on air-flow rate monitoring, is discussed.

  4. A Comparison Study of Sampling and Analyzing Volatile Organic Compounds in Air in Kuwait by Using Tedlar Bags/Canisters and GC-MS with a Cryogenic Trap

    PubMed Central

    Tang, Hongmao; Beg, Khaliq R.; Al-Otaiba, Yousef

    2006-01-01

    Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results. PMID:16699723

  5. A comparison study of sampling and analyzing volatile organic compounds in air in Kuwait by using Tedlar bags/canisters and GC-MS with a cryogenic trap.

    PubMed

    Tang, Hongmao; Beg, Khaliq R; Al-Otaiba, Yousef

    2006-05-12

    Kuwait experiences desert climatic weather. Due to the extreme hot and dry conditions in this country, some analytical phenomena have been discovered. Therefore, a systematic study of sampling and analyzing volatile organic compounds in air by using GC-MS with a cryogenic trap is reported in this paper. This study included comparisons of using different sample containers such as Tedlar bags and SUMMA canisters, and different cryogenic freezing-out air volumes in the trap. Calibration curves for different compounds and improvement of replicated analysis results were also reported here. The study found that using different sample containers produced different results. Analysis of ambient air samples collected in Tedlar bags obtained several volatile organic compounds with large concentrations compared to using SUMMA canisters. Therefore, to choose a sample container properly is a key element for successfully completing a project. Because GC-MS with a cryogenic trap often generates replicated results with poor agreement, an internal standard added to gas standards and air samples by using a gas syringe was tested. The study results proved that it helped to improve the replicated results.

  6. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-03-06

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  7. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-01-31

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  8. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    TEMPLETON, A.M.

    2000-04-10

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less

  9. The study of volatile organic compounds in urban and indoor air

    NASA Astrophysics Data System (ADS)

    Clarkson, Paul Jonathan

    Chapter 1 is a review of the literature concerning the study of volatile organic compounds in the atmosphere. It examines the basic chemistry of the atmosphere and the roles that organic compounds play in it. Also investigated are the methods of sampling and analysing the volatile organic compounds in the air, paying particular attention to the role of solid phase sampling. Chapter 1 also examines the role of volatile organic compounds on air quality. Chapter 2 describes the experimental procedures that were employed during the course of this research project. Chapter 3 examines a multi-method approach to the study of volatile organic compounds in urban and indoor air. The methods employed were capillary electrophoresis, high performance liquid chromatography and gas chromatography. Although good results were obtained for the various methods that were investigated Chapter 3 concludes that a more unified analytical approach is needed to the study of the air. Chapter 4 investigates the possibilities of using a unified approach to the study of VOC's. This is achieved by the development of an air sampling method that uses solid phase extraction cartridges. By investigating many aspects of air sampling mechanisms the results show that a simple yet efficient method for the sampling of VOC in air has been developed. The SPE method is a reusable, yet reliable method that by using sequential solvent desorption has been shown to exhibit some degree of selectivity. The solid phase that gave the best results was styrene-divinyl benzene however other phases were also investigated. The use of a single gas chromatography method was also investigated for the purpose of confirmatory identification of the VOC's. Various detection systems were used including MS and AED. It was shown that by optimising the GC's it was possible to get complimentary results. Also investigated was the possibility of compound tagging in an attempt to confirm the identity of several of the compounds found in the air. Chapter 5 is a theoretical discussion of the ways presenting the data obtained experimentally in an easy to understand way. Instead of targeting 7 or 8 compounds as being representative of air quality it is argued that by using a technique such as Air Fingerprinting, it is possible to show data that is indicative of the whole air sample. Using actual data it is possible to show the origin of the air sample in a simple yet effective way using air fingerprints.Also discussed is the Individual Component Air Quality Index, this is a method of quantifying air quality. By taking into account compound toxicity, atmospheric lifetime and UV exposure, the ICAQI, it is argued, is a technique that presents a more accurate picture of air quality.Chapter 6 concludes the thesis by drawing together the themes and issues that were raised.

  10. 40 CFR 61.53 - Stack sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Stack sampling. 61.53 Section 61.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Mercury ore processing facility. (1) Unless a waiver of emission testing is obtained under...

  11. 40 CFR 61.53 - Stack sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Stack sampling. 61.53 Section 61.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Mercury ore processing facility. (1) Unless a waiver of emission testing is obtained under...

  12. 40 CFR 61.33 - Stack sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Stack sampling. 61.33 Section 61.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Unless a waiver of emission testing is obtained under § 61.13, each owner or operator...

  13. 40 CFR 61.33 - Stack sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Stack sampling. 61.33 Section 61.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Unless a waiver of emission testing is obtained under § 61.13, each owner or operator...

  14. Gas sampling method for determining pollutant concentrations in the flame zone of two swirl-can combustor modules

    NASA Technical Reports Server (NTRS)

    Duerr, R. A.

    1975-01-01

    A gas sampling probe and traversing mechanism were developed to obtain detailed measurements of gaseous pollutant concentrations in the primary and mixing regions of combustors in order to better understand how pollutants are formed. The gas sampling probe was actuated by a three-degree-of-freedom traversing mechanism and the samples obtained were analyzed by an on-line gas analysis system. The pollutants in the flame zone of two different swirl-can combustor modules were measured at an inlet-air temperature of 590 K, pressure of 6 atmospheres, and reference velocities of 23 and 30 meters per second at a fuel-air ratio of 0.02. Typical results show large spatial gradients in the gaseous pollutant concentration close to the swirl-can module. Average concentrations of unburned hydrocarbons and carbon monoxide decrease rapidly in the downstream wake regions of each module. By careful and detailed probing, the effect of various module design features on pollutant formation can be assessed. The techniques presently developed seem adequate to obtain the desired information.

  15. Volatile Organic Compound Emissions from Dairy Farming and their effect on San Joaquin Valley Air Quality

    NASA Astrophysics Data System (ADS)

    Blake, D. R.; Yang, M.; Meinardi, S.; Krauter, C.; Rowland, F. S.

    2009-05-01

    The San Joaquin Valley Air Pollution Control District of California issued a report identifying dairies as a main source of Volatile Organic Compounds (VOCs). A dairy study funded by the California Air Resources Board commenced shortly after the report was issued. Our University of California Irvine group teamed with California State University Fresno to determine the major sources of VOCs from various dairy operations and from a variety of dairy types. This study identified ethanol and methanol as two gases produced in major quantities throughout the dairies in the San Joaquin valley as by-products of yeast fermentation of silage. Three different types of sampling protocols were employed in order to determine the degree of enhancement of the target oxygenates in the valley air shed. Their sources, emission profiles, and emission rates were determined from whole air samples collected at various locations at the six dairies studied. An assessment of the impact of dairy emissions in the valley was achieved by using data obtained on low altitude NASA DC-8 flights through the valley, and from ground level samples collected though out the valley in a grid like design. Our data suggest that a significant amount of O3 production in the valley may come from methanol, ethanol, and acetaldehyde (a photochemical by-product ethanol oxidation). Our findings indicate that improvement to valley air quality may be obtained by focusing on instituting new silage containment practices and regulations.

  16. The simulation of temperature distribution and relative humidity with liquid concentration of 50% using computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Yohana, Eflita; Yulianto, Mohamad Endy; Kwang-Hwang, Choi; Putro, Bondantio; Yohanes Aditya W., A.

    2015-12-01

    The study of humidity distribution simulation inside a room has been widely conducted by using computational fluid dynamics (CFD). Here, the simulation was done by employing inputs in the experiment of air humidity reduction in a sample house. Liquid dessicant CaCl2was used in this study to absorb humidity in the air, so that the enormity of humidity reduction occured during the experiment could be obtained.The experiment was conducted in the morning at 8 with liquid desiccant concentration of 50%, nozzle dimension of 0.2 mms attached in dehumidifier, and the debit of air which entered the sample house was 2.35 m3/min. Both in inlet and outlet sides of the room, a DHT 11 censor was installed and used to note changes in humidity and temperature during the experiment. In normal condition without turning on the dehumidifier, the censor noted that the average temperature inside the room was 28°C and RH of 65%.The experiment result showed that the relative humidity inside a sample house was decreasing up to 52% in inlet position. Further, through the results obtained from CFD simulation, the temperature distribution and relative humidity inside the sample house could be seen. It showed that the concentration of liquid desiccant of 50% experienced a decrease while the relative humidity distribution was considerably good since the average RH was 55% followed by the increase in air temperature of 29.2° C inside the sample house.

  17. Calibration of polyurethane foam (PUF) disk passive air samplers for quantitative measurement of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs): factors influencing sampling rates.

    PubMed

    Hazrati, Sadegh; Harrad, Stuart

    2007-03-01

    PUF disk passive air samplers are increasingly employed for monitoring of POPs in ambient air. In order to utilize them as quantitative sampling devices, a calibration experiment was conducted. Time integrated indoor air concentrations of PCBs and PBDEs were obtained from a low volume air sampler operated over a 50 d period alongside the PUF disk samplers in the same office microenvironment. Passive sampling rates for the fully-sheltered sampler design employed in our research were determined for the 51 PCB and 7 PBDE congeners detected in all calibration samples. These values varied from 0.57 to 1.55 m3 d(-1) for individual PCBs and from 1.1 to 1.9 m3 d(-1) for PBDEs. These values are appreciably lower than those reported elsewhere for different PUF disk sampler designs (e.g. partially sheltered) employed under different conditions (e.g. in outdoor air), and derived using different calibration experiment configurations. This suggests that sampling rates derived for a specific sampler configuration deployed under specific environmental conditions, should not be extrapolated to different sampler configurations. Furthermore, our observation of variable congener-specific sampling rates (consistent with other studies), implies that more research is required in order to understand fully the factors that influence sampling rates. Analysis of wipe samples taken from the inside of the sampler housing, revealed evidence that the housing surface scavenges particle bound PBDEs.

  18. Ambient air particulates and particulate-bound mercury Hg(p) concentrations: dry deposition study over a Traffic, Airport, Park (T.A.P.) areas during years of 2011-2012.

    PubMed

    Fang, Guor-Cheng; Lin, Yen-Heng; Zheng, Yu-Cheng

    2016-02-01

    The main purpose of this study was to monitor ambient air particles and particulate-bound mercury Hg(p) in total suspended particulate (TSP) concentrations and dry deposition at the Hung Kuang (Traffic), Taichung airport and Westing Park sampling sites during the daytime and nighttime, from 2011 to 2012. In addition, the calculated/measured dry deposition flux ratios of ambient air particles and particulate-bound mercury Hg(p) were also studied with Baklanov & Sorensen and the Williams models. For a particle size of 10 μm, the Baklanov & Sorensen model yielded better predictions of dry deposition of ambient air particulates and particulate-bound mercury Hg(p) at the Hung Kuang (Traffic), Taichung airport and Westing Park sampling site during the daytime and nighttime sampling periods. However, for particulates with sizes 20-23 μm, the results obtained in the study reveal that the Williams model provided better prediction results for ambient air particulates and particulate-bound mercury Hg(p) at all sampling sites in this study.

  19. Single Particle Analysis by Combined Chemical Imaging to Study Episodic Air Pollution Events in Vienna

    NASA Astrophysics Data System (ADS)

    Ofner, Johannes; Eitenberger, Elisabeth; Friedbacher, Gernot; Brenner, Florian; Hutter, Herbert; Schauer, Gerhard; Kistler, Magdalena; Greilinger, Marion; Lohninger, Hans; Lendl, Bernhard; Kasper-Giebl, Anne

    2017-04-01

    The aerosol composition of a city like Vienna is characterized by a complex interaction of local emissions and atmospheric input on a regional and continental scale. The identification of major aerosol constituents for basic source appointment and air quality issues needs a high analytical effort. Exceptional episodic air pollution events strongly change the typical aerosol composition of a city like Vienna on a time-scale of few hours to several days. Analyzing the chemistry of particulate matter from these events is often hampered by the sampling time and related sample amount necessary to apply the full range of bulk analytical methods needed for chemical characterization. Additionally, morphological and single particle features are hardly accessible. Chemical Imaging evolved to a powerful tool for image-based chemical analysis of complex samples. As a complementary technique to bulk analytical methods, chemical imaging can address a new access to study air pollution events by obtaining major aerosol constituents with single particle features at high temporal resolutions and small sample volumes. The analysis of the chemical imaging datasets is assisted by multivariate statistics with the benefit of image-based chemical structure determination for direct aerosol source appointment. A novel approach in chemical imaging is combined chemical imaging or so-called multisensor hyperspectral imaging, involving elemental imaging (electron microscopy-based energy dispersive X-ray imaging), vibrational imaging (Raman micro-spectroscopy) and mass spectrometric imaging (Time-of-Flight Secondary Ion Mass Spectrometry) with subsequent combined multivariate analytics. Combined chemical imaging of precipitated aerosol particles will be demonstrated by the following examples of air pollution events in Vienna: Exceptional episodic events like the transformation of Saharan dust by the impact of the city of Vienna will be discussed and compared to samples obtained at a high alpine background site (Sonnblick Observatory, Saharan Dust Event from April 2016). Further, chemical imaging of biological aerosol constituents of an autumnal pollen breakout in Vienna, with background samples from nearby locations from November 2016 will demonstrate the advantages of the chemical imaging approach. Additionally, the chemical fingerprint of an exceptional air pollution event from a local emission source, caused by the pull down process of a building in Vienna will unravel the needs for multisensor imaging, especially the combinational access. Obtained chemical images will be correlated to bulk analytical results. Benefits of the overall methodical access by combining bulk analytics and combined chemical imaging of exceptional episodic air pollution events will be discussed.

  20. Assessment of depleted uranium in South-Western Iran.

    PubMed

    Yousefi, Hossein; Najafi, Abdullah

    2013-10-01

    Depleted uranium (DU) has been used in a number of conflicts most notably during the Gulf War in Iraq and existence of it has been reported in Kuwait by IAEA experts. Due to heavy sand storms prevailing into the direction to South West of Iran transporting sand originating from Iraq, the probability that DU could be moved is considered high. Therefore it was decided to take some air and soil samples near border line and some nearest cities. The study was focused on finding DU in air and soil of these south-west provinces. 22 air samples and 20 soil samples were collected and analyzed on their contents of uranium isotopes by alpha, beta and gamma spectrometry. The air and soil samples have been measured by use of an alpha-beta counter and by a gamma spectrometer, respectively. Results showed that there is no radiation impact from DU and so no DU has been transported via sand storms since all results were obtained below the detection limit. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. HFC-152a and HFC-134a emission estimates and characterization of CFCs, CFC replacements, and other halogenated solvents measured during the 2008 ARCTAS campaign (CARB phase) over the South Coast Air Basin of California

    NASA Astrophysics Data System (ADS)

    Barletta, B.; Nissenson, P.; Meinardi, S.; Dabdub, D.; Sherwood Rowland, F.; Vancuren, R. A.; Pederson, J.; Diskin, G. S.; Blake, D. R.

    2011-03-01

    This work presents results from the NASA Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) study. Whole air samples were obtained on board research flights that flew over California during June 2008 and analyzed for selected volatile organic compounds, including several halogenated species. Samples collected over the South Coast Air Basin of California (SoCAB), which includes much of Los Angeles (LA) County, were compared with samples from inflow air masses over the Pacific Ocean. The levels of many halocarbon species were enhanced significantly over the SoCAB, including compounds regulated by the Montreal Protocol and subsequent amendments. Emissions estimates of HFC-152a (1,1-difluoroethane, CH3CHF2; 0.82 ± 0.11 Gg) and HFC-134a (1,1,1,2-tetrafluoroethane, CH2FCF3; 1.16 ± 0.22 Gg) in LA County for 2008 were obtained using the observed HFC:carbon monoxide (CO) enhancement ratio. Emission rates also were calculated for the SoCAB (1.60 ± 0.22 Gg yr-1 for HFC-152a and 2.12 ± 0.28 Gg yr-1 for HFC-134a) and then extrapolated to the United States (32 ± 4 Gg yr-1 for HFC-152a and 43 ± 6 Gg yr-1 for HFC-134a) using population data. In addition, emission rates of the two HFCs in LA County and SoCAB were calculated by a second method that utilizes air quality modeling. Emissions estimates obtained using both methods differ by less than 25% for the LA County and less than 45% for the SoCAB.

  2. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-100 at the Conclusion of 6A

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-100 (6A) flight to the ISS is reported. ISS air samples were taken in March and April 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. An unplanned "first-entry" sample of the MPLM2 (multipurpose logistics module) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Endeavour using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contribution). Because of the Freon 218 (octafluoropropane, OFP) leak, its contribution to the NMVOC is indicated in brackets. When comparing the NMVOC values with the 25 mg/cubic m guideline, the OFP contributions should be subtracted. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample.

  3. Spacelab Charcoal Analyses

    NASA Technical Reports Server (NTRS)

    Slivon, L. E.; Hernon-Kenny, L. A.; Katona, V. R.; Dejarme, L. E.

    1995-01-01

    This report describes analytical methods and results obtained from chemical analysis of 31 charcoal samples in five sets. Each set was obtained from a single scrubber used to filter ambient air on board a Spacelab mission. Analysis of the charcoal samples was conducted by thermal desorption followed by gas chromatography/mass spectrometry (GC/MS). All samples were analyzed using identical methods. The method used for these analyses was able to detect compounds independent of their polarity or volatility. In addition to the charcoal samples, analyses of three Environmental Control and Life Support System (ECLSS) water samples were conducted specifically for trimethylamine.

  4. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres.

    PubMed

    Napoli, Christian; Marcotrigiano, Vincenzo; Montagna, Maria Teresa

    2012-08-02

    Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC) was evaluated at rest (in the morning before the beginning of surgical activity) and in operational (during surgery). The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256) and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7) for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.

  5. Collection and Analysis of Firn Air from the South Pole, 2001

    NASA Astrophysics Data System (ADS)

    Butler, J. H.; Montzka, S. A.; Battle, M.; Clarke, A. D.; Mondeel, D. J.; Lind, J. A.; Hall, B. D.; Elkins, J. W.

    2001-12-01

    In January 2001, we collected an archive of 20th century air from the firn (snowpack) at the South Pole. Samples were collected into separate pairs of 3L glass flasks for measurements of O2/N2 (Bowdoin/Princeton) and carbon cycle gases (CMDL); individual 3L stainless steel and glass flasks for measurements of halocarbons, N2O, SF6, and COS; large (33L) stainless steel canisters for maintaining an archive of air for future analyses; and a few canisters each for measurement of 14CH4 (NIWA/CSIRO) and very low-level analyses of SF6 (SIO). Although it was hoped to obtain air dating back to the turn of the century, the analyses suggest that the earliest date was 1925 for CO2 and the mid- to late teens for heavier gases such as methyl bromide or methyl chloride. This talk will compare the analyses of halocarbons in these recently collected samples to those of air in flasks sampled at the South Pole in 1995. We also will present some results for compounds not measured in the 1995 South Pole samples owing to a paucity of air. Measurements made of the same gases in the firn air at both ends of this six-year interval, along with real-time atmospheric measurements of the same gases, are useful in evaluating assumptions about diffusion in the firn and may allow for the direct calculation of diffusion coefficients at low temperatures. This, in turn, would improve age estimates for firn air samples. New measurements will add to our existing histories established for the 20th century from analyses of firn air samples collected in both Greenland and Antarctica.

  6. A contribution to reduce sampling variability in the evaluation of deoxynivalenol contamination of organic wheat grain.

    PubMed

    Hallier, Arnaud; Celette, Florian; Coutarel, Julie; David, Christophe

    2013-01-01

    Fusarium head blight caused by different varieties of Fusarium species is one of the major serious worldwide diseases found in wheat production. It is therefore important to be able to quantify the deoxynivalenol concentration in wheat. Unfortunately, in mycotoxin quantification, due to the uneven distribution of mycotoxins within the initial lot, it is difficult, or even impossible, to obtain a truly representative analytical sample. In previous work we showed that the sampling step most responsible for variability was grain sampling. In this paper, it is more particularly the step scaling down from a laboratory sample of some kilograms to an analytical sample of a few grams that is investigated. The naturally contaminated wheat lot was obtained from an organic field located in the southeast of France (Rhône-Alpes) from the year 2008-2009 cropping season. The deoxynivalenol level was found to be 50.6 ± 2.3 ng g⁻¹. Deoxynivalenol was extracted with a acetonitrile-water mix and quantified by gas chromatography-electron capture detection (GC-ECD). Three different grain sampling techniques were tested to obtain analytical samples: a technique based on manually homogenisation and division, a second technique based on the use of a rotating shaker and a third on the use of compressed air. Both the rotating shaker and the compressed air techniques enabled a homogeneous laboratory sample to be obtained, from which representative analytical samples could be taken. Moreover, the techniques did away with many repetitions and grinding. This study, therefore, contributes to sampling variability reduction in the evaluation of deoxynivalenol contamination of organic wheat grain, and then, at a reasonable cost.

  7. MEASUREMENT OF THE ARTIFICIAL RADIOACTIVITY OF THE AIR AND OF FALL-OUT (in Italian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amadesi, P.; Cervellati, A.; Melandri, C.

    1959-01-01

    The results of the measurement of the artificial radioactivity of the air and of fall-out made in Italy from June 1958 to February 1959 are reported. The measurement stations were located at Bologna, Milan, Genoa, Trieste, Naples, Resina, and Bari. The techniques for collecting the samples and measuring their activity are described. Histograms of the activity obtained at the various stations are given. The meteorological factors affecting the activity and the correlation with nuclear explosions are discussed. The methods used to separate Ba/sup 137/, Sr/sup 90/, and Sr/sup 89/ in the fall-out samples are given. The gamma spectra obtained aremore » discussed. (J.S.R.)« less

  8. Evaluation and application of a passive air sampler for polycylic aromatic hydrocarbons (PAHs).

    PubMed

    Esen, Fatma; Evci, Yildiz M; Tasdemir, Yucel

    2017-08-24

    Sampling of 15 PAHs by the use of both passive air sampler developed (D-PAS) in our research group and PAS (C-PAS) having widespread use in the literature was conducted to compare the performances of the samplers. Sampling was carried out for 1-year period (February 2013-February 2014), in different sampling periods by employing D-PAS and C-PAS. D-PAS and C-PAS were run in parallel for 10, 20, 30, 40 and 60 days. Sampling rates were calculated for both PASs by the use of concentration values obtained from a high-volume air sampler (HVAS). It was determined that calculated sampling values are different from each other by definition of design of C-PAS and D-PAS and difference in environment as velocity of wind and temperature are having different effects upon sampling rates. Collected σ 15 PAHs amounts of 10-day periods in spring, summer, autumn and winter were obtained as 576 ± 333, 209 ± 29, 2402 ± 910 and 664 ± 246 ng for D-PAS and 1070 ± 522, 318 ± 292, 6062 ± 1501 and 6089 ± 4018 ng for C-PAS, respectively. In addition, according to seasons, when collected PAHs in two different samplers were considered, similar results were obtained for the summer time in which no combustion takes place with the aim of domestic heating, while there were differences determined for the seasons with combustion in need of domestic heating. Gas-phase σ 15 PAHs' concentrations were reported depending on seasons in the spring, summer, autumn and winter sequences as 46 ± 32, 9 ± 3, 367 ± 207 and 127 ± 93 ng m -3 for HVAS, respectively.

  9. Extensive severe fever with thrombocytopenia syndrome virus contamination in surrounding environment in patient rooms.

    PubMed

    Ryu, B-H; Kim, J Y; Kim, T; Kim, M-C; Kim, M J; Chong, Y-P; Lee, S-O; Choi, S-H; Kim, Y S; Woo, J H; Kim, S-H

    2018-01-31

    Severe fever with thrombocytopenia syndrome (SFTS) is an emerging tick-borne disease in Korea and China. Although there is previous evidence of person-to-person transmission via direct contact with body fluids, the role of environmental contamination by SFTS virus (SFTSV) in healthcare settings has not been established. We therefore investigated the contamination of the healthcare environment by SFTSV. We investigated the possible contamination of hospital air and surfaces with SFTSV transmission by collecting air and swabbing environmental surface samples in two hospitals treating six SFTS patients between March and September 2017. The samples were tested using real-time RT-PCR for SFTS M and S segments. Of the six SFTS patients, four received mechanical ventilation and three died. Five rooms were occupied by those using mechanical ventilation or total plasma exchange therapy in isolation rooms without negative pressure and one room was occupied by a patient bedridden due to SFTS. SFTSV was detected in 14 (21%) of 67 swab samples. Five of 24 swab samples were obtained from fomites including stethoscopes, and 9 of 43 were obtained from fixed structures including doorknobs and bed guardrails. Some samples from fixed structures such as television monitors and sink tables were obtained in areas remote from the patients. SFTSV RNA was not detected in five air samples from three patients' rooms. Our data suggest that SFTSV contamination was extensive in surrounding environments in SFTS patients' rooms. Therefore, more strict isolation methods and disinfecting procedures should be considered when managing SFTS patients. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  10. Seasonal variation, sources and gas/particle partitioning of polycyclic aromatic hydrocarbons in Guangzhou, China.

    PubMed

    Yang, Yunyun; Guo, Pengran; Zhang, Qian; Li, Deliang; Zhao, Lan; Mu, Dehai

    2010-05-15

    Air samples were collected weekly at an urban site and a suburban site in Guangzhou City, China, from April 2005 to March 2006, to measure the concentrations of polycyclic aromatic hydrocarbons (PAHs) in the ambient air and study their seasonal variations, gas/particle partitioning, origins and sources. The concentrations of summation Sigma16-PAHs (particle+gas) were 129.9+/-73.1 ng m(-)(3) at the urban site and 120.4+/-48.5 ng m(-)(3) at the suburban site, respectively. It was found that there was no significant difference in PAH concentrations between the urban and suburban sites. Seasonal variations of PAH concentrations at the two sampling sites were similar, with higher levels in the winter that gradually decreased to the lowest levels in the summer. The average concentrations of summation Sigma16-PAHs in the winter samples were approximately three times higher than those of the summer samples because in the summer local emissions dominated, and in the winter the contribution from outside sources or transported PAHs is increased. The plot of logK(p) versus logP(L)(0) for the data sets of summer and winter season samples had significantly different slopes at both sampling sites. The slopes for the winter samples were steeper than those for the summer samples. It was also observed that gas/particle partitioning of PAHs showed different characteristics depending on air parcel trajectories. Steeper slopes were obtained for an air parcel that traveled across the continent to the sampling site from the northern or northeastern sector, whereas shallower slopes were obtained for air masses that traveled across the sea from the southern or eastern sector. Diagnostic ratio analytical results imply that the origins of PAHs were mainly from petroleum combustion and coal/biomass burning. The anthracene/phenanthrene and benzo[a]anthracene/chrysene ratios in the winter were significantly lower than those in the summer, which indicate that there might be long-range transported PAH input to Guangzhou in the winter. Copyright 2010 Elsevier B.V. All rights reserved.

  11. Temporal fluctuation of the lead level in the cord blood of neonates in Taipei.

    PubMed

    Hwang, Y H; Wang, J D

    1990-01-01

    From August 1985 to September 1987, 9,502 cord blood samples were obtained from the Taipei Municipal Maternal and Child Hospital. A total of 205 cord blood samples chosen randomly from newborns without parental exposure to lead were analyzed by flameless atomic absorption spectrophotometry. The average blood lead level was .36 +/- .11 mumol/l (7.48 +/- 2.25 micrograms/dl). A similar analysis was performed on samples obtained from 160 newborns whose fathers had occupational lead exposure. In both groups, the average concentration of lead in cord blood in the summer was statistically greater than that in the winter. Air lead and total amount of lead in gasoline consumed in Taipei appeared to be associated with this seasonal fluctuation in the average lead level of cord blood. After considering alternative sources, we conclude that the seasonal fluctuation of cord blood lead is probably influenced by air lead produced from the combustion of gasoline.

  12. Development of functional spaghetti enriched in bioactive compounds using barley coarse fraction obtained by air classification.

    PubMed

    Verardo, Vito; Gómez-Caravaca, Ana Maria; Messia, Maria Cristina; Marconi, Emanuele; Caboni, Maria Fiorenza

    2011-09-14

    Barley byproducts obtained by air classification have been used to produce a different barley functional spaghetti, which were compared to different commercial whole semolina samples. Total, insoluble, and soluble fiber and β-glucan contents of the barley spaghetti were found to be greater than those of commercial samples. Furthermore, it was proved that barley spaghetti reached the FDA requirements, which could allow these pastas to deserve the health claims "good source of dietary fiber" and "may reduce the risk of heart disease". When the barley coarse fraction was used, a flavan-3-ols enrichment and an increase of antioxidant activity were reported, while commercial samples showed the absence of flavan-3-ols and a higher presence of phenolic acids and tannins. Whole semolina commercial spaghetti had a significantly higher content of phenolic acids than semolina spaghetti samples. Besides, it was observed that when vital gluten was added to the spaghetti formulation, phenolic compounds were blocked in the gluten network and were partially released during the cooking process.

  13. The Covariance between Air Pollution Annoyance and Noise Annoyance, and Its Relationship with Health-Related Quality of Life.

    PubMed

    Shepherd, Daniel; Dirks, Kim; Welch, David; McBride, David; Landon, Jason

    2016-08-06

    Air pollution originating from road traffic is a known risk factor of respiratory and cardiovascular disease (both in terms of chronic and acute effects). While adverse effects on cardiovascular health have also been linked with noise (after controlling for air pollution), noise exposure has been commonly linked to sleep impairment and negative emotional reactions. Health is multi-faceted, both conceptually and operationally; Health-Related Quality of Life (HRQOL) is one of many measures capable of probing health. In this study, we examine pre-collected data from postal surveys probing HRQOL obtained from a variety of urban, suburban, and rural contexts across the North Island of New Zealand. Analyses focus on the covariance between air pollution annoyance and noise annoyances, and their independent and combined effects on HRQOL. Results indicate that the highest ratings of air pollution annoyance and noise annoyances were for residents living close to the motorway, while the lowest were for rural residents. Most of the city samples indicated no significant difference between air pollution- and noise-annoyance ratings, and of all of the correlations between air pollution- and noise-annoyance, the highest were found in the city samples. These findings suggest that annoyance is driven by exposure to environmental factors and not personality characteristics. Analysis of HRQOL indicated that air pollution annoyance predicts greater variability in the physical HRQOL domain while noise annoyance predicts greater variability in the psychological, social and environmental domains. The lack of an interaction effect between air pollution annoyance and noise annoyance suggests that air pollution and noise impact on health independently. These results echo those obtained from objective measures of health and suggest that mitigation of traffic effects should address both air and noise pollution.

  14. The Covariance between Air Pollution Annoyance and Noise Annoyance, and Its Relationship with Health-Related Quality of Life

    PubMed Central

    Shepherd, Daniel; Dirks, Kim; Welch, David; McBride, David; Landon, Jason

    2016-01-01

    Air pollution originating from road traffic is a known risk factor of respiratory and cardiovascular disease (both in terms of chronic and acute effects). While adverse effects on cardiovascular health have also been linked with noise (after controlling for air pollution), noise exposure has been commonly linked to sleep impairment and negative emotional reactions. Health is multi-faceted, both conceptually and operationally; Health-Related Quality of Life (HRQOL) is one of many measures capable of probing health. In this study, we examine pre-collected data from postal surveys probing HRQOL obtained from a variety of urban, suburban, and rural contexts across the North Island of New Zealand. Analyses focus on the covariance between air pollution annoyance and noise annoyances, and their independent and combined effects on HRQOL. Results indicate that the highest ratings of air pollution annoyance and noise annoyances were for residents living close to the motorway, while the lowest were for rural residents. Most of the city samples indicated no significant difference between air pollution- and noise-annoyance ratings, and of all of the correlations between air pollution- and noise-annoyance, the highest were found in the city samples. These findings suggest that annoyance is driven by exposure to environmental factors and not personality characteristics. Analysis of HRQOL indicated that air pollution annoyance predicts greater variability in the physical HRQOL domain while noise annoyance predicts greater variability in the psychological, social and environmental domains. The lack of an interaction effect between air pollution annoyance and noise annoyance suggests that air pollution and noise impact on health independently. These results echo those obtained from objective measures of health and suggest that mitigation of traffic effects should address both air and noise pollution. PMID:27509512

  15. Air monitoring of volatile organic compounds at relevant receptors during hydraulic fracturing operations in Washington County, Pennsylvania.

    PubMed

    Maskrey, Joshua R; Insley, Allison L; Hynds, Erin S; Panko, Julie M

    2016-07-01

    A 3-month air monitoring study was conducted in Washington County, Pennsylvania, at the request of local community members regarding the potential risks resulting from air emissions of pollutants related to hydraulic fracturing operations. Continuous air monitoring for total volatile organic compounds was performed at two sampling sites, including a school and a residence, located within 900 m of a hydraulic fracturing well pad that had been drilled prior to the study. Intermittent 24-hour air samples for 62 individual volatile organic compounds were also collected. The ambient air at both sites was monitored during four distinct periods of unconventional natural gas extraction activity: an inactive period prior to fracturing operations, during fracturing operations, during flaring operations, and during another inactive period after operations. The results of the continuous monitoring during fracturing and flaring sampling periods for total volatile organic compounds were similar to the results obtained during inactive periods. Total volatile organic compound 24-hour average concentrations ranged between 0.16 and 80 ppb during all sampling periods. Several individual volatile compounds were detected in the 24-hour samples, but they were consistent with background atmospheric levels measured previously at nearby sampling sites and in other areas in Washington County. Furthermore, a basic yet conservative screening level evaluation demonstrated that the detected volatile organic compounds were well below health-protective levels. The primary finding of this study was that the operation of a hydraulic fracturing well pad in Washington County did not substantially affect local air concentrations of total and individual volatile organic compounds.

  16. Evaluation of particulate air samplers for airborne aflatoxin B1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silas, J.C.; Harrison, M.A.; Carpenter, J.A.

    Five air samplers (Millipore, all-glass impinger, centrifugal, Andersen, and absorbent cotton) were evaluated for their ability to collect airborne grain particles contaminated with aflatoxin B1. Corn dust containing 100 micrograms aflatoxin B1/g was aerosolized within a containment system. Each device sampled 100 I air, thus exchanging the air in the chamber two times. Aflatoxin B1 was extracted from all sampling matrices and was detected and quantitated with thin-layer chromatography and scanning fluorodensitometry. The highest efficiency was obtained with the Millipore sampler, while the efficiencies of the centrifugal and the cotton samplers were almost identical. Efficiency of an Andersen was less,more » with no toxin recovered from an all-glass impinger. Measurement of particle size was accomplished with the Andersen sampler.« less

  17. Is there an association between airborne and surface microbes in the critical care environment?

    PubMed

    Smith, J; Adams, C E; King, M F; Noakes, C J; Robertson, C; Dancer, S J

    2018-04-09

    There are few data and no accepted standards for air quality in the intensive care unit (ICU). Any relationship between airborne pathogens and hospital-acquired infection (HAI) risk in the ICU remains unknown. First, to correlate environmental contamination of air and surfaces in the ICU; second, to examine any association between environmental contamination and ICU-acquired staphylococcal infection. Patients, air, and surfaces were screened on 10 sampling days in a mechanically ventilated 10-bed ICU for a 10-month period. Near-patient hand-touch sites (N = 500) and air (N = 80) were screened for total colony count and Staphylococcus aureus. Air counts were compared with surface counts according to proposed standards for air and surface bioburden. Patients were monitored for ICU-acquired staphylococcal infection throughout. Overall, 235 of 500 (47%) surfaces failed the standard for aerobic counts (≤2.5 cfu/cm 2 ). Half of passive air samples (20/40: 50%) failed the 'index of microbial air' contamination (2 cfu/9 cm plate/h), and 15/40 (37.5%) active air samples failed the clean air standard (<10 cfu/m 3 ). Settle plate data were closer to the pass/fail proportion from surfaces and provided the best agreement between air parameters and surfaces when evaluating surface benchmark values of 0-20 cfu/cm 2 . The surface standard most likely to reflect hygiene pass/fail results compared with air was 5 cfu/cm 2 . Rates of ICU-acquired staphylococcal infection were associated with surface counts per bed during 72h encompassing sampling days (P = 0.012). Passive air sampling provides quantitative data analogous to that obtained from surfaces. Settle plates could serve as a proxy for routine environmental screening to determine the infection risk in ICU. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Deep anterior lamellar keratoplasty: dissection plane with viscoelastic and air can be different.

    PubMed

    Ross, Andrew R; Said, Dalia G; El-Amin, Abdalla; Altaan, Saif; Cabrerizo, Javier; Nubile, Mario; Hogan, Emily; Mastropasqua, Leonardo; Dua, Harminder Singh

    2018-04-03

    To investigate and define the nature of big bubbles (BB) formed by injection of viscoelastic in deep anterior lamellar keratoplasty. Intrastromal injections of 0.1 and 0.3 mL of sodium hyaluronate 1.2% and 0.6% were made into sclera-corneal discs (n = 32) at superficial (anterior-third), midstromal (middle-third) and deep (posterior-third) levels to simulate deep anterior lamellar keratoplasty. Postinjection optical coherence tomograms (OCT) were obtained with the needle in situ. The samples were sectioned and examined histologically. Twelve control samples were injected with air. With superficial injections (n=8) only intrastromal accumulation of viscoelastic was noted. With midstromal injections (n=10) intrastromal accumulation of viscoelastic (n=6) and intrastromal big bubbles (IBB) (n=4) with substantial and variable stromal tissue in the walls were noted. No type 1, type 2 or mixed BB were noted. With deep injections (n=14), type 1 BB (n=4), IBB (n=4) and mixed BB (n=6) were obtained.There was no difference in the results with the two different concentrations of viscoelastic used. With air injection (n=12), 10 type 1 and 1 type 2 BB and 1 mixed BB were obtained. No IBB was noted. BB obtained by injection of viscoelastic and air can be different. The former tends to occur at the site of injection, especially with midstromal injections, takes the form of tissue separation by stretch and tearing and does not cleave in a consistent plane like air. Surgeons should be aware of IBB created by viscodissection and not confuse it for a type1 BB. Intraoperative OCT should help identify IBB. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Evaluation of solid sorbents for the determination of fenhexamid, metalaxyl-M, pyrimethanil, malathion and myclobutanil residues in air samples: application to monitoring malathion and fenhexamid dissipation in greenhouse air using C-18 or Supelpak-2 for sampling.

    PubMed

    Tsiropoulos, Nikolaos G; Bakeas, Evangelos B; Raptis, Vasilios; Batistatou, Stavroula S

    2006-07-28

    A methodology is described for greenhouse air analysis by sampling fenhexamid, pyrimethanil, malathion, metalaxyl-M and myclobutanil in solid sorbents. Pesticides were determined by gas chromatography with NP Detector. The trapping efficiency of XAD-2, XAD-4, Supelpak-2, Florisil and C-18 at different sampling conditions (rate, time and air humidity) and pesticides concentration levels has been evaluated. No breakthrough was observed in the range of concentration studied (0.10-75 microg of each pesticide). In almost all the cases good stability results were obtained. Personal pumps have been used with selected sorbents (Supelpak-2 and C-18) in order to sample malathion and fenhexamid in air of experimental greenhouse after their application in a tomato crop. The dissipation process of the analytes in various time periods after application has been studied. Malathion concentrations varied between 20.1 microg m(-3) just after application and 1.06 microg m(-3) 3 days later. Fenhexamid concentrations, determined by high performance liquid chromatography with UV detection, fall rapidly; after 12 h post-application being below 0.50 microg m(-3).

  20. Rapid, Automated Determination of Elemental Compositions of Ions in Mass Spectra Obtained with an Open-Air Ion Source (2 of 2)

    EPA Science Inventory

    An inexpensive autosampler for a DART/TOFMS provides mass spectra from analytes absorbed on 76 cotton swab, wipe samples in 7.5 min. A field sample carrier simplifies sample collection and provides swabs nearly ready for analysis to the lab. Applications of the high throughput pr...

  1. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres

    PubMed Central

    2012-01-01

    Background Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. Methods The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC) was evaluated at rest (in the morning before the beginning of surgical activity) and in operational (during surgery). Results The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256) and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7) for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. Conclusion It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information. PMID:22853006

  2. Method, system and apparatus for monitoring and adjusting the quality of indoor air

    DOEpatents

    Hartenstein, Steven D.; Tremblay, Paul L.; Fryer, Michael O.; Hohorst, Frederick A.

    2004-03-23

    A system, method and apparatus is provided for monitoring and adjusting the quality of indoor air. A sensor array senses an air sample from the indoor air and analyzes the air sample to obtain signatures representative of contaminants in the air sample. When the level or type of contaminant poses a threat or hazard to the occupants, the present invention takes corrective actions which may include introducing additional fresh air. The corrective actions taken are intended to promote overall health of personnel, prevent personnel from being overexposed to hazardous contaminants and minimize the cost of operating the HVAC system. The identification of the contaminants is performed by comparing the signatures provided by the sensor array with a database of known signatures. Upon identification, the system takes corrective actions based on the level of contaminant present. The present invention is capable of learning the identity of previously unknown contaminants, which increases its ability to identify contaminants in the future. Indoor air quality is assured by monitoring the contaminants not only in the indoor air, but also in the outdoor air and the air which is to be recirculated. The present invention is easily adaptable to new and existing HVAC systems. In sum, the present invention is able to monitor and adjust the quality of indoor air in real time by sensing the level and type of contaminants present in indoor air, outdoor and recirculated air, providing an intelligent decision about the quality of the air, and minimizing the cost of operating an HVAC system.

  3. Factors affecting the sticking of insects on modified aircraft wings

    NASA Technical Reports Server (NTRS)

    Yi, O.; Chitsaz-Z, M. R.; Eiss, N. S.; Wightman, J. P.

    1988-01-01

    Previous work showed that the total number of insects sticking to an aluminum surface was reduced by coating the aluminum surface with elastomers. Due to a large number of possible experimental errors, no correlation between the modulus of elasticity, the elastomer, and the total number of insects sticking to a given elastomer was obtained. One of the errors assumed to be introduced during the road test is a variable insect flux so the number of insects striking one surface might be different from that striking another sample. To eliminate this source of error, the road test used to collect insects was simulated in a laboratory by development of an insect impacting technique using a pipe and high pressure compressed air. The insects are accelerated by a compressed air gun to high velocities and are then impacted with a stationary target on which the sample is mounted. The velocity of an object exiting from the pipe was determined and further improvement of the technique was achieved to obtain a uniform air velocity distribution.

  4. GROUND WATER SAMPLING OF VOCS IN THE WATER/CAPILLARY FRINGE AREA FOR VAPOR INTRUSION ASSESSMENT

    EPA Science Inventory

    Vapor intrusion has recently been considered a major pathway for increased indoor air contamination from certain volatile organic contaminants (VOCs). The recent Draft EPA Subsurface Vapor Intrusion Guidance Document states that ground water samples should be obtained from the u...

  5. Temperature and Atomic Oxygen Effects on Helium Leak Rates of a Candidate Main Interface Seal

    NASA Technical Reports Server (NTRS)

    Penney, Nicholas; Wasowski, Janice L.; Daniels, Christopher C.

    2011-01-01

    Helium leak tests were completed to characterize the leak rate of a 54 in. diameter composite space docking seal design in support of the National Aeronautics and Space Administration s (NASA's) Low Impact Docking System (LIDS). The evaluated seal design was a candidate for the main interface seal on the LIDS, which would be compressed between two vehicles, while docked, to prevent the escape of breathable air from the vehicles and into the vacuum of space. Leak tests completed at nominal temperatures of -30, 20, and 50 C on untreated and atomic oxygen (AO) exposed test samples were examined to determine the influence of both test temperature and AO exposure on the performance of the composite seal assembly. Results obtained for untreated seal samples showed leak rates which increased with increased test temperature. This general trend was not observed in tests of the AO exposed specimens. Initial examination of collected test data suggested that AO exposure resulted in higher helium leak rates, however, further analysis showed that the differences observed in the 20 and 50 C tests between the untreated and AO exposed samples were within the experimental error of the test method. Lack of discernable trends in the test data prevented concrete conclusions about the effects of test temperature and AO exposure on helium leak rates of the candidate seal design from being drawn. To facilitate a comparison of the current test data with results from previous leak tests using air as the test fluid, helium leak rates were converted to air leak rates using standard conversion factors for viscous and molecular flow. Flow rates calculated using the viscous flow conversion factor were significantly higher than the experimental air leakage values, whereas values calculated using the molecular flow conversion factor were significantly lower than the experimentally obtained air leak rates. The difference in these sets of converted flow rates and their deviation from the experimentally obtained air leak rate data suggest that neither conversion factor can be used alone to accurately convert helium leak rates to equivalent air leak rates for the test seals evaluated in this study; other leak phenomena, including permeation, must also be considered.

  6. Elemental accumulation in lichen transplants in the neighborhood of thermal power stations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freitas, M.C.; Reis, M.A.; Alves, L.C.

    1996-12-31

    Lichens are known to be good monitors of air pollution because they easily absorb the chemical elements from air particles. Therefore, the exposure of clean lichens to a polluted region will result in an accumulation of elements emitted by the pollution sources in the lichens. In this work, samples of the lichen Parmelia sulcata were collected from olive tree stems and in a very clean area to gauge pollution. The goal is to obtain a quantitative relation between results obtained via lichens and via airborne particles.

  7. Measurement of Droplet Sizes by the Diffraction Ring Method

    DTIC Science & Technology

    1948-07-27

    for measuring the droplet size distribution in sprays ob- tained by pressure injection of a liquid through an orifice «roby air- stream atomization...Diameter vs Injection Pressure 10 6. Distribution Curves for Spray Sample of Water Injected into Air Stream .... 11 Page ii Page Hi i^ujJa-je jii...tion in sprays obtained by pressure injection of a liquid through an orifice or by air- stream atomization. Perhaps the most widely used method

  8. Field testing of a new flow-through directional passive air sampler applied to monitoring ambient nitrogen dioxide.

    PubMed

    Lin, Chun; McKenna, Paul; Timmis, Roger; Jones, Kevin C

    2010-07-08

    This paper reports the first field deployment and testing of a directional passive air sampler (DPAS) which can be used to cost-effectively identify and quantify air pollutants and their sources. The sampler was used for ambient nitrogen dioxide (NO(2)) over ten weeks from twelve directional sectors in an urban setting, and tested alongside an automatic chemiluminescent monitor. The time-integrated passive directional results were compared with the directional analysis of the active monitoring results using wind data recorded at a weather station. The DPAS discriminated air pollutant signals directionally. The attempts to derive quantitative data yielded reasonable results--usually within a factor of two of those obtained by the chemiluminescent analyser. Ultimately, whether DPAS approaches are adopted will depend on their reliability, added value and cost. It is argued that added value was obtained here from the DPAS approach applied in a routine monitoring situation, by identifying source sectors. Both the capital and running costs of DPAS were <5% of those for the automatic monitor. It is envisaged that different sorbents or sampling media will enable this rotatable DPAS design to be used for other airborne pollutants. In summary, there are reasons to be optimistic that directional passive air sampling, together with careful interpretation of results, will be of added value to air quality practitioners in future.

  9. Stratospheric measurements of ozone-depleting substances and greenhouse gases using AirCores

    NASA Astrophysics Data System (ADS)

    Laube, Johannes; Leedham Elvidge, Emma; Kaiser, Jan; Sturges, Bill; Heikkinen, Pauli; Laurila, Tuomas; Hatakka, Juha; Kivi, Rigel; Chen, Huilin; Fraser, Paul; van der Veen, Carina; Röckmann, Thomas

    2017-04-01

    Retrieving air samples from the stratosphere has previously required aircraft or large balloons, both of which are expensive to operate. The novel "AirCore" technique (Karion et al., 2010) enables stratospheric sampling using weather balloons, which is much more cost effective. AirCores are long (up to 200 m) stainless steel tubes which are placed as a payload on a small balloon, can ascend to over 30 km and fill upon descent, collecting a vertical profile of the atmosphere. Retrieved volumes are much smaller though, which presents a challenge for trace gas analysis. To date, only the more abundant trace gases such as carnon dioxide (CO2) and methane (CH4) have been quantified in AirCores. Halogenated trace gases are also important greenhouse gases and many also deplete stratospheric ozone. Their concentrations are however much lower i.e. typically in the part per trillion (ppt) molar range. We here present the first stratospheric measurements of halocarbons in AirCores obtained using UEA's highly sensitive (detection limits of 0.01-0.1 ppt in 10 ml of air) gas chromatography mass spectrometry system. The analysed air originates from a Stratospheric Air Sub-sampler (Mrozek et al., 2016) which collects AirCore segments after the non-destructive CO2 and CH4 analysis. Successfully measured species include CFC-11, CFC-12, CFC-113, CFC-115, H-1211, H-1301, HCFC-22, HCFC-141b, HCFC-142b, HCFC-133a, and sulphur hexafluoride (SF6). We compare the observed mixing ratios and precisions with data obtained from samples collected during various high-altitude aircraft campaigns between 2009 and 2016 as well as with southern hemisphere tropospheric long-term trends. As part of the ERC-funded EXC3ITE (EXploring stratospheric Composition, Chemistry and Circulation with Innovative Techniques) project more than 40 AirCore flights are planned in the next 3 years with an expanded range of up to 30 gases in order to explore seasonal and interannual variability in the stratosphere. References Karion et al., J. Atmos. Ocean. Technol., 27(11), 1839-1853, 2010 Mrozek et al., Atmos. Meas. Tech., 9, 5607-5620, 2016

  10. Atmospheric particulate measurements in Norfolk, Virginia

    NASA Technical Reports Server (NTRS)

    Storey, R. W., Jr.; Sentell, R. J.; Woods, D. C.; Smith, J. R.; Harris, F. S., Jr.

    1975-01-01

    Characterization of atmospheric particulates was conducted at a site near the center of Norfolk, Virginia. Air quality was measured in terms of atmospheric mass loading, particle size distribution, and particulate elemental composition for a period of 2 weeks. The objectives of this study were (1) to establish a mean level of air quality and deviations about this mean, (2) to ascertain diurnal changes or special events in air quality, and (3) to evaluate instrumentation and sampling schedules. Simultaneous measurements were made with the following instruments: a quartz crystal microbalance particulate monitor, a light-scattering multirange particle counter, a high-volume air sampler, and polycarbonate membrane filters. To assess the impact of meteorological conditions on air quality variations, continuous data on temperature, relative humidity, wind speed, and wind direction were recorded. Particulate elemental composition was obtained from neutron activation and scanning electron microscopy analyses of polycarbonate membrane filter samples. The measured average mass loading agrees reasonably well with the mass loadings determined by the Virginia State Air Pollution Control Board. There are consistent diurnal increases in atmospheric mass loading in the early morning and a sample time resolution of 1/2 hour seems necessary to detect most of the significant events.

  11. Biomonitoring polycyclic aromatic hydrocarbons by Salix matsudana leaves: A comparison with the relevant air content and evaluation of environmental parameter effects

    NASA Astrophysics Data System (ADS)

    Zhao, Xiangai; He, Miao; Shang, Haibo; Yu, Hongling; Wang, Hao; Li, Huijie; Piao, Jingyi; Quinto, Maurizio; Li, Donghao

    2018-05-01

    Studies on seasonal distribution characteristics of polycyclic aromatic hydrocarbons (PAHs) in Salix matsudana leaves covering its annual life cycle were carried out in order to evaluate plant leaf response sensitivity to air pollution. Salix matsudana leaves were collected throughout different development phases of plant leaf inclusive of bud break to fallen leaves, covering from spring (May) to autumn (November). Simultaneously, particle and gas samples were collected using a high volume air sampler. Seven different PAHs were determined simultaneously in these samples. The temperature dependence of the partitioning of PAHs in air and plant leaves was investigated and the results were incorporated into a mathematical model. The measured plant/air partition coefficients have been found to be exponentially proportional to the reciprocal temperature, in agreement with theoretical expectations. Furthermore, in order to define the influence of different parameters on PAH adsorption on plant leaves, area and lipid leaf content were also measured. Results demonstrated that temperature plays a very important role in PAHs partitioning and that this value should be carefully considered during sampling, in order to obtain the best correlation between PAHs concentration in air and leaves.

  12. Impact of postharvest drying conditions on in vitro starch digestibility and estimated glycemic index of cooked non-waxy long-grain rice (Oryza sativa L.).

    PubMed

    Donlao, Natthawuddhi; Ogawa, Yukiharu

    2017-02-01

    Wet paddy needs to be dried to reduce its moisture content after harvesting. In this study, effects of postharvest drying condition on in vitro starch digestibility and estimated glycemic index of cooked rice (Oryza sativa L.) were investigated. Varying drying conditions, i.e. hot-air drying at 40, 65, 90 and 115 °C, and sun drying were applied to raw paddy. After husking and polishing, polished grains were cooked using an electric rice cooker. Cooked samples were analyzed for their moisture content and amount of resistant and total starch. Five samples in both intact grain and slurry were digested under simulated in vitro gastrointestinal digestion process. The in vitro starch digestion rate was measured and the hydrolysis index (HI) and estimated glycemic index (eGI) were calculated. Cooked rice obtained from hot-air drying showed relatively lower HI and eGI than that obtained from sun-drying. Among samples from hot-air drying treatment, eGI of cooked rice decreased with increasing drying temperature, except for the drying temperature of 115 °C. As a result, cooked rice from the hot-air drying at 90 °C showed lowest eGI. The results indicated that cooked rice digestibility was affected by postharvest drying conditions. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  13. Stable Carbon Isotope Ratios in Atmospheric VOC across the Asian Summer Monsoon Anticyclone obtained during the OMO-ASIA campaign

    NASA Astrophysics Data System (ADS)

    Krebsbach, Marc; Koppmann, Ralf; Meisehen, Thomas

    2017-04-01

    The automated high volume air sampling system (MIRAH) has been deployed during the atmospheric measurement campaign OMO-ASIA (Oxidation Mechanism Observations) with the German High Altitude - Long-range research aircraft (HALO) in July and August 2015. The intensive measurement period with base stations in Paphos (Cyprus) and Gan (Maldives) focussed on oxidation processes and air pollution chemistry downwind of the South Asia summer monsoon anticyclone, a pivot area critical for air quality and climate change, both regionally and worldwide. The measurement region covered the Eastern Mediterranean region, the Arabian Peninsula, Egypt, and the Arabian Sea. In total 194 air samples were collected on 17 flights in a height region from 3 km up to 15 km. The air samples were analysed for stable carbon isotope ratios in VOC with GC-C-IRMS in the laboratory afterwards. We determined stable carbon isotope ratios and mixing ratios of several aldehydes, ketones, alcohols, and aromatics. The large extent of the investigated area allowed for encountering air masses with different origin, characteristic, and atmospheric processing, e.g. Mediterranean air masses, crossing of polluted filaments and remnants of the Asian monsoon outflow, split of the Asian monsoon anticyclone. In this presentation we will show first results and interpretations supported by HYSPLIT backward trajectories.

  14. A Comparison of the Plastic Flow Response of a Powder Metallurgy Nickel Base Superalloy (Postprint)

    DTIC Science & Technology

    2017-04-01

    average diameter of 315 nm. The c¢-solvus tempera- ture, Tc0 , was 1430 K (1157 C). As determined by a series of long- time heat treatments followed...obtained in a mode of simple shear via the torsion of tubular samples. Similar in design to that employed by various researchers in the 1980s,[28,29] the...INTL (STINFO COPY) AIR FORCE RESEARCH LABORATORY MATERIALS AND MANUFACTURING DIRECTORATE WRIGHT-PATTERSON AIR FORCE BASE, OH 45433-7750 AIR

  15. Effect of Inoculation Techniques and Relative Humidity on the Growth of Molds on the Surfaces of Yellow Layer Cakes

    PubMed Central

    Fustier, Patrick; Lafond, Alain; Champagne, Claude P.; Lamarche, François

    1998-01-01

    Four inoculation techniques were compared for initiation of growth on cake surfaces: spot, air cabinet, spray (atomizer), and talc addition methods. Molds were isolated from commercial cakes and were identified as Aspergillus sydowii, Aspergillus ochraceus, Penicillium funiculosum, and Eurotium herbariorum. Cake surfaces were inoculated with mold spores and incubated under three equilibrium relative humidity (ERH) levels: 97, 85, and 75%. Random contamination by spores in a ventilated air cabinet was the simplest method of inoculation, but standard deviations in the inoculation rates (20% on a relative scale) were almost twice those observed with the other methods. The spot method was the most reproducible. Cake samples inoculated in the air cabinet had colony counts 10 times lower than those obtained for potato dextrose agar plates at 97% ERH, which was not the case with the spray and talc methods. Growth of molds was much slower in the samples incubated in 75% relative humidity, with all methods. Colony counts were generally similar in systems adjusted at 85 to 97% ERH but were lower for samples incubated at 75% ERH. In comparisons of the shelf life estimates obtained by the various inoculation methods, a correlation coefficient (r2) of 0.70 was obtained between the spot method and the other methods of inoculation, while talc, air cabinet, and spray shelf life data were correlated better (r2 ≈ 0.97). The spot method appeared to be the method of choice in consideration of ease of use, precision, and the ability to enable the study of the effects of the environment on mold-free shelf life as well as on the rate of growth of molds on cakes. PMID:16349479

  16. Endothelial Inflammatory Transcriptional Responses Induced by Plasma Following Inhalation of Diesel Emissions

    PubMed Central

    Schisler, Jonathan C.; Ronnebaum, Sarah M.; Madden, Michael; Channell, Meghan M.; Campen, Matthew J.; Willis, Monte S.

    2016-01-01

    Background Air pollution, especially emissions derived from traffic sources, is associated with adverse cardiovascular outcomes. However, it remains unclear how inhaled factors drive extrapulmonary pathology. Objectives Previously, we found that canonical inflammatory response transcripts were elevated in cultured endothelial cells treated with plasma obtained after exposure compared with pre-exposure samples or filtered air (sham) exposures. While the findings confirmed the presence of bioactive factor(s) in the plasma after diesel inhalation, we wanted to better examine the complete genomic response to investigate 1) major responsive transcripts and 2) collected response pathways and ontogeny that may help to refine this method and inform the pathogenesis. Methods We assayed endothelial RNA with gene expression microarrays, examining the responses of cultured endothelial cells to plasma obtained from 6 healthy human subjects exposed to 100 μg/m3 diesel exhaust or filtered air for 2 h on separate occasions. In addition to pre-exposure baseline samples, we investigated samples obtained immediately-post and 24h-post exposure. Results Microarray analysis of the coronary artery endothelial cells challenged with plasma identified 855 probes that changed over time following diesel exhaust exposure. Over-representation analysis identified inflammatory cytokine pathways were upregulated both at the 2 and 24 h condition. Novel pathways related to FOX transcription factors and secreted extracellular factors were also identified in the microarray analysis. Conclusions These outcomes are consistent with our recent findings that plasma contains bioactive and inflammatory factors following pollutant inhalation. The specific study design implicates a novel pathway related to inflammatory blood borne components that may drive the extrapulmonary toxicity of ambient air pollutants. PMID:25942053

  17. Atmospheric Hydrogen (H2) Concentrations from the CSIRO GASLAB Flask Sampling Network (1992 - 2001)

    DOE Data Explorer

    Steele, L. P. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Atmospheric Research, Aspendale, Victoria, Australia; Krummel, P. B. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Atmospheric Research, Aspendale, Victoria, Australia; Langenfelds, R. L. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Atmospheric Research, Aspendale, Victoria, Australia

    2003-01-01

    Air samples from nine sites were collected from the CSIRO GASLAB Flask Sampling Network for the purpose of monitoring the atmospheric hydrogen (H2) concentrations. The listed data were obtained from flask air samples returned to the CSIRO GASLAB for analysis. Typical sample storage times ranged from days to weeks for some sites (e.g., Cape Grim) to as much as one year for Macquarie Island and the Antarctic sites. Experiments carried out to test for any change in sample H22 mixing ratio during storage have shown no consistent and systematic drift in these flask types over test periods of several months to years (Cooper et al., 1999). An annual cycle of H2 is evident, reflecting the seasonal nature of some of the major sources and sinks (Novelli et al., 1999).

  18. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, G.J.; Motes, B.G.; Bird, S.K.; Kotter, D.K.

    1996-03-26

    Apparatus for obtaining a whole gas sample, is composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method is described for obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant. 3 figs.

  19. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, Gary J.; Motes, Billy G.; Bird, Susan K.; Kotter, Dale K.

    1996-01-01

    Apparatus for obtaining a whole gas sample, composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method of obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant.

  20. Occurrence and quantitative microbial risk assessment of Cryptosporidium and Giardia in soil and air samples.

    PubMed

    Balderrama-Carmona, Ana Paola; Gortáres-Moroyoqui, Pablo; Álvarez-Valencia, Luis Humberto; Castro-Espinoza, Luciano; Mondaca-Fernández, Iram; Balderas-Cortés, José de Jesús; Chaidez-Quiroz, Cristóbal; Meza-Montenegro, María Mercedes

    2014-09-01

    Cryptosporidium oocysts and Giardia cysts can be transmitted by the fecal-oral route and may cause gastrointestinal parasitic zoonoses. These zoonoses are common in rural zones due to the parasites being harbored in fecally contaminated soil. This study assessed the risk of illness (giardiasis and cryptosporidiosis) from inhaling and/or ingesting soil and/or airborne dust in Potam, Mexico. To assess the risk of infection, Quantitative Microbial Risk Assessment (QMRA) was employed, with the following steps: (1) hazard identification, (2) hazard exposure, (3) dose-response, and (4) risk characterization. Cryptosporidium oocysts and Giardia cysts were observed in 52% and 57%, respectively, of total soil samples (n=21), and in 60% and 80%, respectively, of air samples (n=12). The calculated annual risks were higher than 9.9 × 10(-1) for both parasites in both types of sample. Soil and air inhalation and/or ingestion are important vehicles for these parasites. To our knowledge, the results obtained in the present study represent the first QMRAs for cryptosporidiosis and giardiasis due to soil and air inhalation/ingestion in Mexico. In addition, this is the first evidence of the microbial air quality around these parasites in rural zones. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Demolition of a hospital building by controlled explosion: the impact on filamentous fungal load in internal and external air.

    PubMed

    Bouza, E; Peláez, T; Pérez-Molina, J; Marín, M; Alcalá, L; Padilla, B; Muñoz, P; Adán, P; Bové, B; Bueno, M J; Grande, F; Puente, D; Rodríguez, M P; Rodríguez-Créixems, M; Vigil, D; Cuevas, O

    2002-12-01

    The demolition of a maternity building at our institution provided us with the opportunity to study the load of filamentous fungi in the air. External (nearby streets) and internal (within the hospital buildings) air was sampled with an automatic volumetric machine (MAS-100 Air Samplair) at least daily during the week before the demolition, at 10, 30, 60, 90,120, 180, 240, 420, 540 and 660 min post-demolition, daily during the week after the demolition and weekly during weeks 2, 3 and 4 after demolition. Samples were duplicated to analyse reproducibility. Three hundred and forty samples were obtained: 115 external air, 69 'non-protected' internal air and 156 protected internal air [high efficiency particulate air (HEPA) filtered air under positive pressure]. A significant increase in the colony count of filamentous fungi occurred after the demolition. Median colony counts of external air on demolition day were significantly higher than from internal air (70.2 cfu/m(3) vs 35.8 cfu/m(3)) (P < 0.001). Mechanical demolition on day +4 also produced a significant difference between external and internal air (74.5 cfu/m(3) vs 41.7 cfu/m(3)). The counts returned to baseline levels on day +11. Most areas with a protected air supply yielded no colonies before demolition day and remained negative on demolition day. The reproducibility of the count method was good (intra-assay variance: 2.4 cfu/m(3)). No episodes of invasive filamentous mycosis were detected during the three months following the demolition. Demolition work was associated with a significant increase in the fungal colony counts of hospital external and non-protected internal air. Effective protective measures may be taken to avoid the emergence of clinical infections. Copyright 2002 The Hospital Infection Society

  2. Fuel additives and heat treatment effects on nanocrystalline zinc ferrite phase composition

    NASA Astrophysics Data System (ADS)

    Hu, Ping; Pan, De-an; Wang, Xin-feng; Tian, Jian-jun; Wang, Jian; Zhang, Shen-gen; Volinsky, Alex A.

    2011-03-01

    Nanocrystalline ZnFe 2O 4 powder was prepared by the auto-combustion method using citric acid, acetic acid, carbamide and acrylic acid as fuel additives. Pure spinel zinc ferrite with the crystallite size of about 15 nm can be obtained by using acrylic acid as fuel additive. Samples prepared using other fuel additives contain ZnO impurities. In order to eliminate ZnO impurities, the sample prepared with citric acid as fuel additive was annealed at different temperatures up to 1000 °C in air and in argon. Annealed powders have pure ZnFe 2O 4 phase when annealing temperature is higher than 650 °C in air. Sample annealed at 650 °C in air is paramagnetic. However, annealed powders become a mixture of Fe 3O 4 and FeO after annealing at 1000 °C in argon atmosphere due to Zn volatility and the reduction reaction.

  3. Investigation of the Best Approach for Assessing Human Exposure to Poly- and Perfluoroalkyl Substances through Indoor Air.

    PubMed

    Padilla-Sánchez, Juan A; Papadopoulou, Eleni; Poothong, Somrutai; Haug, Line S

    2017-11-07

    Per- and polyfluoroalkyl substances (PFASs), including fluorotelomer alcohols (FTOHs), perfluoroalkyl sulfonamidoethanols (FOSEs), and perfluoroalkyl sulfonamides (FOSAs), were assessed in 61 residential indoor air and 15 personal air samples collected in Oslo area, Norway. FTOHs were detected in all samples, and the median concentrations in residential indoor air were 2970, 10400, and 3120 pg m -3 for 6:2, 8:2, and 10:2 FTOH, respectively. This is similar to or higher than previously reported in studies from the same geographical area and worldwide. FOSEs and FOSAs were detected in 49-70% and 7-13% of the residential indoor air samples, respectively. The median FTOH concentrations observed in personal air were 1970, 7170, and 1590 pg m -3 for 6:2, 8:2, and 10:2 FTOH, respectively, which is 30 to 50% lower than the median concentrations in residential indoor air. No FOSEs or FOSAs were detected above the method detection limit (MDL) in the personal air samples. Intakes of perfluorohexanoate (PFHxA), perfluoroheptanoate (PFHpA), perfluorooctanoate (PFOA), perfluorononanoate (PFNA), perfluorodecanoate (PFDA), perfluoroundecanoate (PFUnDA), and perfluorooctyl sulfonate (PFOS) through inhalation and biotransformation of PFAS precursors in air were estimated. Median intakes of 1.7, 0.17, 5.7, 0.57, 1.8, 0.18, and 2.3 pg kg bw -1 day -1 were obtained in residential indoor air, while 1.0, 0.10, 3.3, 0.33, 0.88, and 0.09 pg kg bw -1 day -1 were found in personal air for PFHxA, PFHpA, PFOA, PFNA, PFDA, PFUnDA, and PFOS, respectively. The median PFOA intakes from residential indoor air (5.7 pg kg bw -1 day -1 ) and personal air (3.3 pg kg bw -1 day -1 ) were both around 5 orders of magnitude lower than the tolerable daily intake (TDI) reported by the European Food Safety Authority (EFSA).

  4. Global sensing of gaseous and aerosol trace species using automated instrumentation on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P. J.; Papathakos, L. C.

    1978-01-01

    The Global Atmospheric Sampling Program (GASP) is collecting and analyzing data on gaseous and aerosol trace contaminants in the upper troposphere and lower stratosphere. Measurements are obtained from automated systems installed on four 747 airliners flying global air routes. Improved instruments and analysis techniques are providing an expanding data base for trace species including ozone, carbon monoxide, water vapor, condensation nuclei, and mass concentration of sulfates and nitrates. Simultaneous measurements of several trace species obtained frequently can be used to identify the source of the air mass as being typically tropospheric or stratospheric.

  5. Global sensing of gaseous and aerosol trace species using automated instrumentation on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P. J.; Papathakos, L. C.

    1977-01-01

    The Global Atmospheric Sampling Program (GASP) by NASA is collecting and analyzing data on gaseous and aerosol trace species in the upper troposphere and lower stratosphere. Measurements are obtained from automated systems installed on four 747 airliners flying global air routes. Advances were made in airborne sampling instrumentation. Improved instruments and analysis techniques are providing an expanding data base for trace species including ozone, carbon monoxide, water vapor, condensation nuclei and mass concentrations of sulfates and nitrates. Simultaneous measurements of several trace species obtained frequently can be used to uniquely identify the source of the air mass as being typically tropospheric or stratospheric. A quantitative understanding of the tropospheric-stratospheric exchange processes leads to better knowledge of the atmospheric impact of pollution through the development of improved simulation models of the atmosphere.

  6. Demonstration/Validation of the Snap Sampler Passive Ground Water Sampling Device for Sampling Inorganic Analytes at the Former Pease Air Force Base

    DTIC Science & Technology

    2009-07-01

    viii Unit Conversion Factors...sampler is also an economic alternative for sampling for inorganic analytes. ERDC/CRREL TR-09-12 xii Unit Conversion Factors Multiply By To Obtain...head- space and then covered with two layers of tightly fitting aluminum foil. To dissolve the analytes, the solutions were stirred for approximately

  7. Compliance Testing of Eielson Air Force Base Central Heating and Power Plant, Coal Fired Boiler Number 3, Eielson Air Force Base, Alaska

    DTIC Science & Technology

    1988-12-01

    a flue gas grab sample for orsat analysis (measures oxygen, and carbon dioxide for stack gas molecular weight determination and emissions correction... molecular weight, was obtained during particulate sampling. Testing was initially started on boiler 2 at the maximum rated steam output of 120,000 lbs/hr...I, r*~td AN[D l FL B( R\\ ViQ( lPjN L!II(,t 1 (d) Open burning of put.rcible iear- i\\ % ~i~ emisions , ec.dirig c dn jc p. c ,f1 pre- cri :rig pair

  8. Development of a sensitive methodology for the analysis of chlorobenzenes in air by combination of solid-phase extraction and headspace solid-phase microextraction.

    PubMed

    Barro, Ruth; Ares, Sergio; Garcia-Jares, Carmen; Llompart, Maria; Cela, Rafael

    2004-08-06

    In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) has been used to determine chlorobenzenes in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). Then, the adsorbent was transferred into a glass vial and SPME was performed. The quantification was carried out using gas chromatography (GC)-electron-capture detection or GC-MS. Several SPME coatings (100 microm poly(dimethylsiloxane) (PDMS), 75 microm Carboxen (CAR)-PDMS, 65 microm PDMS-divinylbenzene (DVB), 65 microm PDMS-DVB and 85 microm polyacrylate (PA) were evaluated, obtaining the highest responses with Carbowax (CW)- PDMS for the most volatile chlorobenzenes, and with PDMS-DVB or CW-DVB fibers for the semivolatile compounds. To optimize some other factors that could affect the SPME step, a factorial design was used. Kinetic studies of the SPME process were also performed. Concerning the SPE step, breakthrough was studied, showing that 2.5 m3 of air could be processed without losses of the most volatile compounds. The performance of the method was evaluated. External calibration, which does not require the complete sampling process, demonstrated to be suitable, obtaining good linearity (R2 > 0.99) for all chlorobenzenes. Recovery studies were performed at two concentration levels (4 and 40 ng/m3), obtaining quantitative recoveries (>80%). Limits of detection at the sub ng/m3 were achieved for all the target compounds.

  9. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Englebrecht; I. Kavouras; D. Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d).more » The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  10. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Englebrecht; I. Kavouras; D. Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailermore » is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.« less

  11. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D. Campbell

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailermore » is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.« less

  12. DOE/NV/26383-LTR2008-01 Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D. Campbell

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d).more » The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  13. Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D. Campbell

    2009-04-02

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al.,more » 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  14. Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Engelbrecht; I. Kavouras; D Campbell

    2008-08-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al.,more » 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.« less

  15. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    PubMed

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  16. Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules.

    PubMed

    O'Connor, Sean; O'Connor, Paula Fey; Feng, H Amy; Ashley, Kevin

    2014-10-01

    An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 - 4 mg of National Institute of Standards and Technology Standard Reference Material ® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision S r at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝ rt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules.

  17. Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules

    PubMed Central

    O'Connor, Sean; O'Connor, Paula Fey; Feng, H. Amy

    2015-01-01

    Summary An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 – 4 mg of National Institute of Standards and Technology Standard Reference Material® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision Sr at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝrt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules. PMID:26435581

  18. Atmospheric CO2 Records from Sites in the Atmospheric Environment Service Air Sampling Network (1975 and 1994)

    DOE Data Explorer

    Trivett, N. B.A. [Atmospheric Environment Service, Downsview, Ontario, Canada; Hudec, V. C. [Atmospheric Environment Service, Downsview, Ontario, Canada; Wong, C. S. [Marine Carbon Research Centre, Institute of Ocean Sciences, Sidney, British Columbia, Canada

    1997-01-01

    From the mid-1970s through the mid-1990s, air samples were collected for the purposes of monitoring atmospheric CO2 from four sites in the AES air sampling network. Air samples were collected approximately once per week, between 12:00 and 16:00 local time, in a pair of evacuated 2-L thick-wall borosilicate glass flasks. Samples were collected under preferred conditions of wind speed and direction (i.e., upwind of the main station and when winds are strong and steady). The flasks were evacuated to pressures of ~1 × 10-4 mbar or 0.01 Pa prior to being sent to the stations. The airwas not dried during sample collection. The flask data from Alert show an increase in the annual atmospheric CO2 concentration from 341.35 parts per million by volume (ppmv) in 1981 to 357.21 ppmv in 1991. For Cape St. James, Trivett and Higuchi (1989) reported that the mean annual rate of increase, obtained from the slope of a least-squares regression line through the annual averages, was 1.43 ppmv per year. In August 1992, the weather station at Cape St. James was automated; as a result, the flask sampling program was discontinued at this site. Estevan Point, on the West Coast of Vancouver Island, was chosen as a replacement station. Sampling at Estevan Point started in 1992; thus, the monthly and annual CO2record from Estevan Point is too short to show any long-term trends. The sampling site at Sable Island, off the coast of Nova Scotia, was established in 1975. The flask data from Sable Island show an increase in the annual atmospheric CO2 concentration from 334.49 parts per million by volume (ppmv) in 1977 (the first full year of data) to 356.02 ppmv in 1990. For Sable Island, Trivett and Higuchi (1989) reported that the mean annual rate of increase, obtained from the slope of a least-squares regression line through the annual averages, was 1.48 ppmv per year.

  19. In-Line Reactions and Ionizations of Vaporized Diphenylchloroarsine and Diphenylcyanoarsine in Atmospheric Pressure Chemical Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Okumura, Akihiko; Takada, Yasuaki; Watanabe, Susumu; Hashimoto, Hiroaki; Ezawa, Naoya; Seto, Yasuo; Takayama, Yasuo; Sekioka, Ryoji; Yamaguchi, Shintaro; Kishi, Shintaro; Satoh, Takafumi; Kondo, Tomohide; Nagashima, Hisayuki; Nagoya, Tomoki

    2016-07-01

    We propose detecting a fragment ion (Ph2As+) using counter-flow introduction atmospheric pressure chemical ionization ion trap mass spectrometry for sensitive air monitoring of chemical warfare vomiting agents diphenylchloroarsine (DA) and diphenylcyanoarsine (DC). The liquid sample containing of DA, DC, and bis(diphenylarsine)oxide (BDPAO) was heated in a dry air line, and the generated vapor was mixed into the humidified air flowing through the sampling line of a mass spectrometer. Humidity effect on the air monitoring was investigated by varying the humidity of the analyzed air sample. Evidence of the in-line conversion of DA and DC to diphenylarsine hydroxide (DPAH) and then BDPAO was obtained by comparing the chronograms of various ions from the beginning of heating. Multiple-stage mass spectrometry revealed that the protonated molecule (MH+) of DA, DC, DPAH, and BDPAO could produce Ph2As+ through their in-source fragmentation. Among the signals of the ions that were investigated, the Ph2As+ signal was the most intense and increased to reach a plateau with the increased air humidity, whereas the MH+ signal of DA decreased. It was suggested that DA and DC were converted in-line into BDPAO, which was a major source of Ph2As+.

  20. Identifying source regions for the atmospheric input of PCDD/Fs to the Baltic Sea

    NASA Astrophysics Data System (ADS)

    Sellström, Ulla; Egebäck, Anna-Lena; McLachlan, Michael S.

    PCDD/F contamination of the Baltic Sea has resulted in the European Union imposing restrictions on the marketing of several fish species. Atmospheric deposition is the major source of PCDD/Fs to the Baltic Sea, and hence there is a need to identify the source regions of the PCDD/Fs in ambient air over the Baltic Sea. A novel monitoring strategy was employed to address this question. During the winter of 2006-2007 air samples were collected in Aspvreten (southern Sweden) and Pallas (northern Finland). Short sampling times (24 h) were employed and only samples with stable air mass back trajectories were selected for analysis of the 2,3,7,8-substituted PCDD/F congeners. The range in the PCDD/F concentrations from 40 samples collected at Aspvreten was a factor of almost 50 (range 0.6-29 fg TEQ/m 3). When the samples were grouped according to air mass origin into seven compass sectors, the variability was much lower (typically less than a factor of 3). This indicates that air mass origin was the primary source of the variability. The contribution of each sector to the PCDD/F contamination over the Baltic Sea during the winter half year of 2006/2007 was calculated from the average PCDD/F concentration for each sector and the frequency with which the air over the Baltic Sea came from that sector. Air masses originating from the south-southwest, south-southeast and east segments contributed 65% of the PCDDs and 75% of the PCDFs. Strong correlations were obtained between the concentrations of most of the PCDD/F congeners and the concentration of soot. These correlations can be used to predict the PCDD/F concentrations during the winter half year from inexpensive soot measurements.

  1. The radiocarbon hydroxyl technique

    NASA Technical Reports Server (NTRS)

    Campbell, Malcolm J.; Sheppard, John C.

    1994-01-01

    The Radiocarbon Technique depends upon measuring the rate of oxidation of CO in an essentially unperturbed sample of air. The airborne technique is slightly different. Hydroxyl concentrations can be calculated directly; peroxyl concentrations can be obtained by NO doping.

  2. Use of sulfur hexafluoride airflow studies to determine the appropriate number and placement of air monitors in an alpha inhalation exposure laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newton, G.J.; Hoover, M.D.

    1995-12-01

    Determination of the appropriate number and placement of air monitors in the workplace is quite subjective and is generally one of the more difficult tasks in radiation protection. General guidance for determining the number and placement of air sampling and monitoring instruments has been provided by technical reports such as Mishima, J. These two documents and other published guidelines suggest that some insight into sampler placement can be obtained by conducting airflow studies involving the dilution and clearance of the relatively inert tracer gas sulfur hexafluoride (SF{sub 6}) in sampler placement studies and describes the results of a study donemore » within the ITRI alpha inhalation exposure laboratories. The objectives of the study were to document an appropriate method for conducting SF{sub 6} dispersion studies, and to confirm the appropriate number and placement of air monitors and air samplers within a typical ITRI inhalation exposure laboratory. The results of this study have become part of the technical bases for air sampling and monitoring in the test room.« less

  3. Use of a numerical simulation approach to improve the estimation of air-water exchange fluxes of polycyclic aromatic hydrocarbons in a coastal zone.

    PubMed

    Lai, I-Chien; Lee, Chon-Lin; Ko, Fung-Chi; Lin, Ju-Chieh; Huang, Hu-Ching; Shiu, Ruei-Feng

    2017-07-15

    The air-water exchange is important for determining the transport, fate, and chemical loading of polycyclic aromatic hydrocarbons (PAHs) in the atmosphere and in aquatic systems. Investigations of PAH air-water exchange are mostly based on observational data obtained using complicated field sampling processes. This study proposes a new approach to improve the estimation of long-term PAH air-water exchange fluxes by using a multivariate regression model to simulate hourly gaseous PAH concentrations. Model performance analysis and the benefits from this approach indicate its effectiveness at improving the flux estimations and at decreasing the field sampling difficulty. The proposed GIS mapping approach is useful for box model establishment and is tested for visualization of the spatiotemporal variations of air-water exchange fluxes in a coastal zone. The air-water exchange fluxes illustrated by contour maps suggest that the atmospheric PAHs might have greater impacts on offshore sites than on the coastal area in this study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Fungal spore concentrations in two haematopoietic stem cell transplantation (HSCT) units containing distinct air control systems.

    PubMed

    Brun, C P; Miron, D; Silla, L M R; Pasqualotto, A C

    2013-04-01

    Invasive fungal diseases have emerged as important causes of morbidity and mortality in haematological patients. In this study air samples were collected in two haematopoietic stem cell transplantation (HSCT) units, in which distinct air-control systems were in place. In hospital 1 no high-efficiency particulate air (HEPA) filter was available whereas in hospital 2 HSCT rooms were equipped with HEPA filters, with positive air pressure in relation to the corridor. A total of 117 samples from rooms, toilets and corridors were obtained during December 2009 to January 2011, using a six-stage Andersen sampler. In both hospitals, the concentration of potentially pathogenic fungi in the air was reduced in patients' rooms compared to corridors (P < 0·0001). Despite the presence of a HEPA filter in hospital 2, rooms in both hospitals showed similar concentrations of potentially pathogenic fungi (P = 0·714). These findings may be explained by the implementation of additional protective measures in hospital 1, emphasizing the importance of such measures in protected environments.

  5. The classification of the patients with pulmonary diseases using breath air samples spectral analysis

    NASA Astrophysics Data System (ADS)

    Kistenev, Yury V.; Borisov, Alexey V.; Kuzmin, Dmitry A.; Bulanova, Anna A.

    2016-08-01

    Technique of exhaled breath sampling is discussed. The procedure of wavelength auto-calibration is proposed and tested. Comparison of the experimental data with the model absorption spectra of 5% CO2 is conducted. The classification results of three study groups obtained by using support vector machine and principal component analysis methods are presented.

  6. Alpha particle spectroscopy in radon/thoron progeny measurements.

    PubMed

    Thiessen, N P

    1994-12-01

    A comparison is made between the relative variances and counting time requirements for obtaining radon and thoron progeny air concentrations from total alpha count data and from spectroscopically resolved alpha count data collected from air sampling filters. Spectral resolution is shown to have significant advantages, especially in mixed radon/thoron atmospheres. Systematic biases resulting from imperfect energy peak resolution are shown to be subject to accurate mathematical compensation.

  7. Simultaneous determination of hydroquinone, resorcinol, phenol, m-cresol and p-cresol in untreated air samples using spectrofluorimetry and a custom multiple linear regression-successive projection algorithm.

    PubMed

    Pistonesi, Marcelo F; Di Nezio, María S; Centurión, María E; Lista, Adriana G; Fragoso, Wallace D; Pontes, Márcio J C; Araújo, Mário C U; Band, Beatriz S Fernández

    2010-12-15

    In this study, a novel, simple, and efficient spectrofluorimetric method to determine directly and simultaneously five phenolic compounds (hydroquinone, resorcinol, phenol, m-cresol and p-cresol) in air samples is presented. For this purpose, variable selection by the successive projections algorithm (SPA) is used in order to obtain simple multiple linear regression (MLR) models based on a small subset of wavelengths. For comparison, partial least square (PLS) regression is also employed in full-spectrum. The concentrations of the calibration matrix ranged from 0.02 to 0.2 mg L(-1) for hydroquinone, from 0.05 to 0.6 mg L(-1) for resorcinol, and from 0.05 to 0.4 mg L(-1) for phenol, m-cresol and p-cresol; incidentally, such ranges are in accordance with the Argentinean environmental legislation. To verify the accuracy of the proposed method a recovery study on real air samples of smoking environment was carried out with satisfactory results (94-104%). The advantage of the proposed method is that it requires only spectrofluorimetric measurements of samples and chemometric modeling for simultaneous determination of five phenols. With it, air is simply sampled and no pre-treatment sample is needed (i.e., separation steps and derivatization reagents are avoided) that means a great saving of time. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. 10 CFR 431.76 - Uniform test method for the measurement of energy efficiency of commercial warm air furnaces.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... § 431.75) you must locate one or two sampling tubes within six inches downstream from the flue....75). If you use an open end tube, it must project into the flue one-third of the chimney connector diameter. If you use other methods of sampling CO2, you must place the sampling tube so as to obtain an...

  9. Characterization of Air Plane Soot Surrogates using Raman spectroscopy and laser ablation techniques

    NASA Astrophysics Data System (ADS)

    Chazallon, Bertrand; Ortega, Ismael Kenneth; Ikhenazene, Raouf; Pirim, Claire; Carpentier, Yvain; Irimiea, Cornelia; Focsa, Cristian; Ouf, François-Xavier

    2016-04-01

    Aviation alters the composition of the atmosphere globally and can thus drive climate change and ozone depletion [1]. Aircraft exhaust plumes contain species (gases and soot particles) produced by the combustion of kerosene with ambient air in the combustion chamber of the engine. Soot particles emitted by air-planes produce persistent contrails in the upper troposphere in ice-supersaturated air masses that contribute to cloudiness and impact the radiative properties of the atmosphere. These aerosol-cloud interactions represent one of the largest sources of uncertainty in global climate models [2]. Though the formation of atmospheric ice particles has been studied for many years [3], there are still numerous opened questions on nucleation properties of soot particles [4], as the ice nucleation experiments showed a large spread in results depending on the nucleation mode chosen and origin of the soot produced. The reasons behind these discrepancies reside in the different physico-chemical properties (composition, structure) of soot particles produced in different conditions, e.g., with respect to fuel or combustion techniques. In this work, we use Raman microscopy (514 and 785 nm excitation wavelengths) and ablation techniques (Secondary Ions Mass Spectrometry, and Laser Desorption Mass Spectrometry) to characterize soot particle surrogates produced from a CAST generator (propane fuel, four different global equivalence ratios). They are produced as analogues of air-plane soot collected at different engine regimes (PowerJet SaM-146 turbofan) simulating a landing and take-off (LTO) cycle (MERMOSE project (http://mermose.onera.fr/)) [6]. The spectral parameters of the first-order Raman bands of these soot samples are analyzed using a de-convolution approach described by Sadezky et al. (2005) [5]. A systematic Raman analysis is carried out to select a number of parameters (laser wavelength, irradiance at sample, exposure time) that will alter the sample and the resulting spectra. If much literature discussed the most appropriate values of these parameters for analyzing graphite, coals, or amorphous carbon, only few works have dealt with soot, and no published studies have proposed the optimal parameter values for air-plane soot surrogates. In this work, we present the effect of three Raman parameters (laser wavelength, irradiance at sample, exposure time) on air-plane soot surrogates. The obtained results qualitatively indicate higher reactivity of soot samples collected in specific air-oxidation conditions. The surface chemical composition of the soot particles with special focus on PAHs are analyzed by two-Step (Desorption/Ionization) Laser Mass Spectrometry (L2MS) and Time of Fight Secondary Ion Mass Spectrometry (ToF-SIMS) techniques. In both techniques the spectra are obtained using positive polarity, which is better suited for detection of PAHs. A good agreement was obtained between the two techniques for the total PAH content of the analyzed samples. CAST samples are further processed by Raman spectroscopy to get complementary information on their structure. References [1] Lee et al., Atmos. Env. 44, 4678-4734, 2010 [2] IPCC 2014, Chap7: http://www.ipcc.ch [3] L. Dufour, Ciel et Terre, vol 82, p1-36, 1966 [4] C. Hoose & O. Möhler, Atmos.Chem.Phys. 12, 9817-9854, 2012 [5] Sadezky, A., Muckenhuber, H., Grothe, H., Niessner, R. and Pöschl U., (2005) Carbon, 43, 1731-1742. [6] Parent, Laffon, Marhaba, Ferry, Regier, Ortega, Chazallon, Carpentier, Focsa, (2016) Carbon (accepted)

  10. Automated simultaneous measurement of the δ(13) C and δ(2) H values of methane and the δ(13) C and δ(18) O values of carbon dioxide in flask air samples using a new multi cryo-trap/gas chromatography/isotope ratio mass spectrometry system.

    PubMed

    Brand, Willi A; Rothe, Michael; Sperlich, Peter; Strube, Martin; Wendeberg, Magnus

    2016-07-15

    The isotopic composition of greenhouse gases helps to constrain global budgets and to study sink and source processes. We present a new system for high-precision stable isotope measurements of carbon, hydrogen and oxygen in atmospheric methane and carbon dioxide. The design is intended for analyzing flask air samples from existing sampling programs without the need for extra sample air for methane analysis. CO2 and CH4 isotopes are measured simultaneously using two isotope ratio mass spectrometers, one for the analysis of δ(13) C and δ(18) O values and the second one for δ(2) H values. The inlet carousel delivers air from 16 sample positions (glass flasks 1-5 L and high-pressure cylinders). Three 10-port valves take aliquots from the sample stream. CH4 from 100-mL air aliquots is preconcentrated in 0.8-mL sample loops using a new cryo-trap system. A precisely calibrated working reference air is used in parallel with the sample according to the Principle of Identical Treatment. It takes about 36 hours for a fully calibrated analysis of a complete carousel including extractions of four working reference and one quality control reference air. Long-term precision values, as obtained from the quality control reference gas since 2012, account for 0.04 ‰ (δ(13) C values of CO2 ), 0.07 ‰ (δ(18) O values of CO2 ), 0.11 ‰ (δ(13) C values of CH4 ) and 1.0 ‰ (δ(2) H values of CH4 ). Within a single day, the system exhibits a typical methane δ(13) C standard deviation (1σ) of 0.06 ‰ for 10 repeated measurements. The system has been in routine operation at the MPI-BGC since 2012. Consistency of the data and compatibility with results from other laboratories at a high precision level are of utmost importance. A high sample throughput and reliability of operation are important achievements of the presented system to cope with the large number of air samples to be analyzed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Microbiological Surveillance of Operation Theatres: Five Year Retrospective Analysis from a Tertiary Care Hospital in North India

    PubMed Central

    Najotra, Dipender Kaur; Malhotra, Aneeta Singh; Slathia, Poonam; Raina, Shivani; Dhar, Ashok

    2017-01-01

    Introduction: Microbiological contamination of air and environment in the operation theaters (OTs) are major risk factor for surgical site and other hospital-associated infections. Objectives: The aim was to identify bacterial colonization of surfaces and equipment and to determine the microbial contamination of air in the OTs of a tertiary care hospital. Materials and Methods: Five years (January 2010–December 2014) retrospective analysis of the data obtained from routine microbiological surveillance of the five OTs of the hospital was done. Surface samples were taken with wet swabs from different sites and equipment. Bacterial species were isolated and identified by conventional methods. Air quality surveillance of OTs was done by settle plate method. Results: A total of 4387 samples were collected from surfaces and articles of various OTs. Out of these only 195 (4.4%), samples showed bacterial growth and yielded 210 isolates. The predominant species isolated was Bacillus with 184 (87.6%) isolates followed by coagulase-negative Staphylococcus 17 (8.1%), Staphylococcus aureus 6 (2.9%), and Enteroccoccus spp. 3 (1.4%). Analysis of the OT air samples showed least colony forming unit (cfu) rate of air (27 cfu/m3) in ophthalmology OT and highest rate of 133 cfu/m3 in general surgery OT. Conclusion: The study shows that OTs of our hospital showed a very low bacterial contamination rate on surface swabbing and a cfu count per m3 of air well within permissible limits. PMID:28904915

  12. Ecotoxicological studies of environmental samples from Buenos Aires area using a standardized amphibian embryo toxicity test (AMPHITOX).

    PubMed

    Herkovits, Jorge; Perez-Coll, Cristina; Herkovits, Francisco D

    2002-01-01

    The toxicity of 34 environmental samples from potentially polluted and reference stations were evaluated by means of the AMPHITOX test from acute to chronic exposure according to the toxicity found in each sample. The samples were obtained from surface and ground water, leaches, industrial effluents and soils. The data, expressed in acute, short-term chronic and chronic Toxicity Units (TUa, TUstc and TUc) resulted in a maximal value of 1000 TUc, found in a leach, while the lower toxicity value was 1.4 TUa corresponding to two surface water samples. In five samples (four providing from reference places) no toxicity was detected. The results point out the possibility of evaluating the toxicity of a wide diversity of samples by means of AMPHITOX as a customized toxicity test. The fact that almost all samples with suspected toxicity in rivers and streams from the Metropolitan area of Buenos Aires city resulted toxic, indicates the need of enhanced stewardship of chemical substances for environmental and human health protection purposes.

  13. Imaging graphite in air by scanning tunneling microscopy - Role of the tip

    NASA Technical Reports Server (NTRS)

    Colton, R. J.; Baker, S. M.; Driscoll, R. J.; Youngquist, M. G.; Baldeschwieler, J. D.; Kaiser, W. J.

    1988-01-01

    Atomically resolved images of highly oriented pyrolytic graphite (HOPG) in air at point contact have been obtained. Direct contact between tip and sample or contact through a contamination layer provides a conduction mechanism in addition to the exponential tunneling mechanism responsible for scanning tunneling microscopy (STM) imaging. Current-voltage (I-V) spectra were obtained while scanning in the current imaging mode with the feedback circuit interrupted in order to study the graphite imaging mechanism. Multiple tunneling tips are probably responsible for images without the expected hexagonal or trigonal symmetry. The observations indicate that the use of HOPG for testing and calibration of STM instrumentation may be misleading.

  14. Paramagnetism of cobalt-doped ZnO nanoparticles obtained by microwave solvothermal synthesis.

    PubMed

    Wojnarowicz, Jacek; Kusnieruk, Sylwia; Chudoba, Tadeusz; Gierlotka, Stanislaw; Lojkowski, Witold; Knoff, Wojciech; Lukasiewicz, Malgorzata I; Witkowski, Bartlomiej S; Wolska, Anna; Klepka, Marcin T; Story, Tomasz; Godlewski, Marek

    2015-01-01

    Zinc oxide nanopowders doped with 1-15 mol % cobalt were produced by the microwave solvothermal synthesis (MSS) technique. The obtained nanoparticles were annealed at 800 °C in nitrogen (99.999%) and in synthetic air. The material nanostructure was investigated by means of the following techniques: X-ray diffraction (XRD), helium pycnometry density, specific surface area (SSA), inductively coupled plasma optical emission spectrometry (ICP-OES), extended X-ray absorption fine structure (EXAFS) spectroscopy, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and with magnetometry using superconducting quantum interference device (SQUID). Irrespective of the Co content, nanoparticles in their initial state present a similar morphology. They are composed of loosely agglomerated spherical particles with wurtzite-type crystal structure with crystallites of a mean size of 30 nm. Annealing to temperatures of up to 800 °C induced the growth of crystallites up to a maximum of 2 μm in diameter. For samples annealed in high purity nitrogen, the precipitation of metallic α-Co was detected for a Co content of 5 mol % or more. For samples annealed in synthetic air, no change of phase structure was detected, except for precipitation of Co3O4 for a Co content of 15 mol %. The results of the magentometry investigation indicated that all as-synthesized samples displayed paramagnetic properties with a contribution of anti-ferromagnetic coupling of Co-Co pairs. After annealing in synthetic air, the samples remained paramagnetic and samples annealed under nitrogen flow showed a magnetic response under the influences of a magnetic field, likely related to the precipitation of metallic Co in nanoparticles.

  15. Innovative flow controller for time integrated passive sampling using SUMMA canisters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, P.; Farant, J.P.; Cole, H.

    1996-12-31

    To restrict the entry of gaseous contaminants inside evacuated vessels such as SUMMA canisters, mechanical flow controllers are used to collect integrated atmospheric samples. From the passive force generated by the pressure gradient, the motion of gas can be controlled to obtain a constant flow rate. Presently, devices based on the principle of critical orifices are used and they are all limited to an upper integrated sampling time. A novel flow controller which can be designed to achieve any desired sampling time when used on evacuated vessels was recently developed. It can extend the sampling time for hours, days, weeksmore » or even months for the benefits of environmental, engineering and toxicological professionals. The design of the controller is obtained from computer simulations done with an original set of equations derived from fluid mechanic and gas kinetic laws. To date, the experimental results have shown excellent agreement, with predictions obtained from the mathematical model. This new controller has already found numerous applications. Units able to deliver a constant sampling rate between vacuum and approximately -10 inches Hg during continuous long term duration have been used with SUMMA canisters of different volumes (500 ml, 1 litre and 61). Essentially, any combination of sampling time and sampler volume is possible. The innovative flow controller has contributed to an air quality assessment around a sanitary landfill (indoor/outdoor), and inside domestic wastewater and pulpmill sludge treatment facilities. It is presently being used as an alternative methodology for atmospheric sampling in the Russian orbital station Mir. This device affords true long term passive monitoring of selected gaseous air pollutants for environmental studies. 14 refs., 3 figs.« less

  16. Water vapor weathering of Taurus-Littrow orange soil - A pore-structure analysis

    NASA Technical Reports Server (NTRS)

    Cadenhead, D. A.; Mikhail, R. S.

    1975-01-01

    A pore-volume analysis was performed on water vapor adsorption data previously obtained on a fresh sample of Taurus-Littrow orange soil, and the analysis was repeated on the same sample after its exposure to moist air for a period of approximately six months. The results indicate that exposure of an outgassed sample to high relative pressures of water vapor can result in the formation of substantial micropore structure, the precise amount being dependent on the sample pretreatment, particularly the outgassing temperature. Micropore formation is explained in terms of water penetration into surface defects. In contrast, long-term exposure to moist air at low relative pressures appears to reverse the process with the elimination of micropores and enlargement of mesopores possibly through surface diffusion of metastable adsorbent material. The results are considered with reference to the storage of lunar samples.

  17. Methods of obtaining a uniform volume concentration of implanted ions

    NASA Astrophysics Data System (ADS)

    Reutov, V. F.

    1998-05-01

    Three simple practical methods of irradiation with high energy particles (>5 MeV/n), providing the conditions of obtaining a uniform volume concentration of the implanted ions in the massive samples are described in the present paper. Realization of the condition of two-sided irradiation of a plane sample during its rotation in the flux of the projectiles is the basis of the first method. The use of free air as a filter with varying absorbent ability due to the movement of the irradiated sample along ion beam brought to the atmosphere is at the basis of the second method of uniform ion alloying. The third method of obtaining a uniform volume concentration of the implanted ions in a massive sample consists of sample irradiation through the absorbent filter in the shape of a foil curved according to the parabolic law moving along its surface. The first method is the most effective for obtaining a great number of the samples, for mechanical tests, for example, the second one - for irradiation in different gaseous media, the third one - for obtaining high concentration of the implanted ions under controlled (regulated) thermal and deformation conditions.

  18. Carpeting in hospitals: an epidemiological evaluation.

    PubMed Central

    Anderson, R L; Mackel, D C; Stoler, B S; Mallison, G F

    1982-01-01

    Epidemiological and microbiological studies were conducted in a hospital room with carpet (CR) and in one with carpet (NCR). Microbiological profiles were determined with specimens obtained from patients admitted to these rooms. Patient records were reviewed to note infection status and other case identities. Eleven-millimeter cylindrical core samples of carpet were obtained, and swab template techniques were used on the bare floor for subsequent enumeration and identification of contaminating microorganisms. In each sampling period, higher microbial counts per square inch (1 in(2) = ca 6.452 cm(2)) were measured for the carpet than for the bare floor. Recovery rates of Enterobacter spp., Klebsiella pneumoniae, and Escherichia coli were higher from carpet samples than from bare floor samples. Typable organisms (such as E. coli, Pseudomonas aeruginosa, K. pneumoniae, and Staphylococcus aureus) obtained from patients were also more frequently recovered from the carpet than from the bare flooring. Patients who stayed in the CR were shown to be colonized with the same types of organisms as those initially recovered from the carpet. However, no statistically significant differences were found in patients in the CR versus NCR in colonization with all typable and nontypable organisms first found on the floor. Disease in patients was found not to be associated with organisms found as contaminants of the carpet or the bare floor. Air above carpeting contained more consistent concentrations of organisms than air above the bare flooring. PMID:7076814

  19. Headspace screening of fluid obtained from the gut during colonoscopy and breath analysis by proton transfer reaction-mass spectrometry: A novel approach in the diagnosis of gastro-intestinal diseases

    NASA Astrophysics Data System (ADS)

    Lechner, M.; Colvin, H. P.; Ginzel, C.; Lirk, P.; Rieder, J.; Tilg, H.

    2005-05-01

    Background: The diagnosis of many gastro-intestinal diseases is difficult and can often be confirmed only by using invasive diagnostic means. In contrast, the headspace screening of fluid obtained from the gut during colonoscopy and the analysis of exhaled air may be a novel approach for the diagnosis of these diseases.Materials and methods: The screening was performed by using proton transfer reaction-mass spectrometry (PTR-MS) which allows rapid and sensitive measurement. Fluid samples obtained from the gut during colonoscopy were collected from 76 and breath samples from 70 subjects. Mass spectra of healthy controls were created. Afterwards these spectra were compared with those of patients suffering from inflammatory bowel diseases (IBD; Crohn's disease and ulcerative colitis; n = 10) and irritable bowel syndrome (IBS; n = 7).Results: Significant differences in the mass spectra could be observed both in the headspace of the fluid and in the exhaled air comparing patients with healthy controls.Conclusions: This study is the first describing headspace screening of fluid obtained from the gut during colonoscopy, possibly presenting a novel diagnostic tool in the differential diagnosis of gastro-intestinal diseases.

  20. Proteomics of exhaled breath: methodological nuances and pitfalls.

    PubMed

    Kurova, Viktoria S; Anaev, Eldar C; Kononikhin, Alexey S; Fedorchenko, Kristina Yu; Popov, Igor A; Kalupov, Timothey L; Bratanov, Dmitriy O; Nikolaev, Eugenie N; Varfolomeev, Sergey D

    2009-01-01

    The analysis of exhaled breath condensate (EBC) can be an alternative to traditional endoscopic sampling of lower respiratory tract secretions. This is a simple non-invasive method of diagnosing respiratory diseases, in particular, respiratory inflammatory processes. Samples were collected with a special device-condenser (ECoScreen, VIASYS Healthcare, Germany), then treated with trypsin according to the proteomics protocol for standard protein mixtures and analyzed by nanoflow high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) with a 7-Tesla Finnigan LTQ-FT mass spectrometer (Thermo Electron, Germany). Mascot software (Matrixscience) was used for screening the database NCBInr for proteins corresponding to the peptide maps that were obtained. EBCs from 17 young healthy non-smoking donors were collected. Different methods for concentrating protein were compared in order to optimize EBC preparations for proteomic analysis. The procedure that was chosen allowed identification of proteins exhaled by healthy people. The major proteins in the condensates were cytoskeletal keratins. Another 12 proteins were identified in EBC from healthy non-smokers. Some keratins were found in the ambient air and may be considered exogenous components of exhaled air. Knowledge of the normal proteome of exhaled breath allows one to look for biomarkers of different disease states in EBC. Proteins in ambient air can be identified in the respiratory tract and should be excluded from the analysis of the proteome of EBC. The results obtained allowed us to choose the most effective procedure of sample preparation when working with samples containing very low protein concentrations.

  1. Mold contamination in a controlled hospital environment: a 3-year surveillance in southern Italy.

    PubMed

    Caggiano, Giuseppina; Napoli, Christian; Coretti, Caterina; Lovero, Grazia; Scarafile, Giancarlo; De Giglio, Osvalda; Montagna, Maria Teresa

    2014-11-15

    Environmental monitoring of airborne filamentous fungi is necessary to reduce fungal concentrations in operating theaters and in controlled environments, and to prevent infections. The present study reports results of a surveillance of filamentous fungi carried out on samples from air and surfaces in operating theaters and controlled environments in an Italian university hospital. Sampling was performed between January 2010 and December 2012 in 32 operating theaters and five departments with high-risk patients. Indoor air specimens were sampled using a microbiological air sampler; Rodac contact plates were used for surface sampling. Fungal isolates were identified at the level of genera and species. Sixty-one samples (61/465; 13.1%) were positive for molds, with 18 from controlled environments (18/81; 22.2%) and 43 (43/384; 11.2%) from operating theaters. The highest air fungal load (AFL, colony-forming units per cubic meter [CFU/m(3)]) was recorded in the ophthalmology operating theater, while the pediatric onco-hematology ward had the highest AFL among the wards (47 CFU/m(3)). The most common fungi identified from culture of air specimens were Aspergillus spp. (91.8%), Penicillium spp., (6%) and Paecilomyces spp. (1.5%). During the study period, a statistically significant increase in CFU over time was recorded in air-controlled environments (p = 0.043), while the increase in AFL in operating theaters was not statistically significant (p = 0.145). Molds were found in 29.1% of samples obtained from surfaces. Aspergillus fumigatus was the most commonly isolated (68.5%). Our findings will form the basis for action aimed at improving the air and surface quality of these special wards. The lack of any genetic analysis prevented any correlation of fungal environmental contamination with onset of fungal infection, an analysis that will be undertaken in a prospective study in patients admitted to the same hospital.

  2. Development of Atmospheric Air 85Kr Monitoring Methodology on the Territory of the USSR

    NASA Astrophysics Data System (ADS)

    Pakhomov, Sergei; Dubasov, Yury

    2014-05-01

    Highly sensitive, low-background and high-performance method of beta-radioactivity measurements of the gas samples was developed in mid-eighties at Khlopin Radium institute. This method was based on the use of the serial automated installation for liquid scintillation measurements and special scintillating cells. Cells were equipped with the gas valve, and their internal surface were covered by a thin layer of organic scintillator. This method found was successfully was applied for 85Kr activity measurements in atmospheric krypton samples and for 85Kr concentration measurements in atmospheric air. For the first time, method developed for 85Kr activity measurements, was practically tested in May - June, 1986, while studying radioactive pollution characteristics in the air basin of Russia and Ukraine after the Chernobyl NPP accident. Thus for sampling of atmospheric krypton the industrial krypton-xenon mix manufactured at air-separating plants, located in the cities of Cherepovets, Lipetsk, Krivoi Rog and Enakiyevo was used. In the end of April and in the first half of May it was determined that 1,5-fold excess concentrations of 85Kr in atmospheric air were observed in atmospheric air of considerable part of the European territory of Russia and Ukraine During the period from 1987 to 1991 this method was used for monitoring of 85Kr on the territory of the former USSR in the air basin of Russia, Ukraine and Kazakhstan. Industrial krypton-xenon mix manufactured at 14 large air-separating plants was also used for sampling. Six of them were situated in Russia (Novomoskovsk, Lipetsk, Cherepovets, Chelyabinsk, Nizhni Tagil, Orsk). Seven - in Ukraine (Enakiyevo, Kommunarsk, Krivoi Rog, Makeyevka, Mariupol, Severodonetsk, Dneprodzerzhinsk). One plant was situated in Temirtau, in Kazakhstan. The analysis indicated that in Krivoi Rog; Dneprozhzerzhinsk; Severodonetsk; Makeyevka; Mariupol; Enakiyevo; Kommunarsk; Novomoskovsk and Cherepovets the average 85Kr concentration in atmospheric air was close to background level during monitoring. But in Lipetsk; Orsk; Nizhni Tagil and Temirtau 10-20% excess of background level was systematically observed. In Chelyabinsk concentration of 85Kr steadily exceeded this level by 2-3 times, and incidentally exceeded it for order. Generally, during this period about 1500 values of concentration 85Kr were obtained. Actually, the large-scale monitoring system of atmospheric 85Kr with a binding of sampling points to 14 air-separating plants covered the territory 1000 x 3000 km was created. The developed method of 85Kr activity measurement was successfully applied also when carrying out expedition works in Northern Atlantic during the period from 1987 to 1994 with use o ZIF-1000 cryogenic installation for sampling, which initially was intended for liquid nitrogen manufacturing at the ship. Generally, 80 measurements of 85Kr concentration were obtained using this method. It was determined, that the average concentration of 85Kr in atmospheric air in the open regions of the Atlantic Ocean, were close to background level during monitoring. The concentrations of 85Kr steadily exceeded this level by 2-3 times in English Channel, and incidentally exceeded it in tens times.

  3. Emission measurements for a lean premixed propane/air system at pressures up to 30 atmospheres

    NASA Technical Reports Server (NTRS)

    Roffe, G.; Venkataramani, K. S.

    1978-01-01

    The emissions of a lean premixed system of propane/air were measured in a flametube apparatus. Tests were conducted at inlet temperatures of 600K and 800K and pressures of 10 atm and 30 atm over a range of equivalence ratios. The data obtained were combined with previous data taken in the same apparatus to correlate nitrogen oxide emissions with operating conditions. Sampling probe design was found to have a pronounced effect on measured CO levels but did not influence measurements. The most effective probe tested was one which combined thermal and pressure quenching of the gas sample.

  4. Meteorological and operational aspects of 46 clear air turbulence sampling missions with an instrument B-57B aircraft. Volume 1: Program summary

    NASA Technical Reports Server (NTRS)

    Davis, R. E.; Champine, R. A.; Ehernberger, L. J.

    1979-01-01

    The results of 46 clear air turbulence (CAT) probing missions conducted with an extensively instrumented B-57B aircraft are summarized. Turbulence samples were obtained under diverse conditions including mountain waves, jet streams, upper level fronts and troughs, and low altitude mechanical and thermal turbulence. CAT was encouraged on 20 flights comprising 77 data runs. In all, approximately 4335 km were flown in light turbulence, 1415 km in moderate turbulence, and 255 km in severe turbulence during the program. The flight planning, operations, and turbulence forecasting aspects conducted with the B-57B aircraft are presented.

  5. BiOCl micro-assembles consisting of ultrafine nanoplates: A high performance electro-catalyst for air electrode of Al-air batteries

    NASA Astrophysics Data System (ADS)

    Yuan, Jinlan; Wang, Jin; She, Yiyi; Hu, Jing; Tao, Pengpeng; Lv, Fucong; Lu, Zhouguang; Gu, Yingying

    2014-10-01

    BiOCl micro-assembles appearing spherical and plate-like in shape consisting of ultrafine nanoplates were successfully synthesized by a simple hydrothermal method. The obtained BiOCl micro-assembles were characterized as oxygen reduction reaction (ORR) catalyst for air electrode of aluminum air batteries by using linear polarization and constant-current discharge techniques. The effect of precursor concentration on the electrochemical properties of the air electrodes based on the synthesized BiOCl micro-assembles was intensively investigated. The results demonstrated that the BiOCl catalyst exhibited promising ORR performance. Koutecky-Levich analysis indicated that a two-electron reaction was favored for the ORR mechanism of the BiOCl (0.18) sample.

  6. A study of atmospheric mixing of trace gases by aerial sampling with a multi-rotor drone

    NASA Astrophysics Data System (ADS)

    Chang, Chih-Chung; Chang, Chih-Yuan; Wang, Jia-Lin; Lin, Ming-Ren; Ou-Yang, Chang-Feng; Pan, Hsiang-Hsu; Chen, Yen-Chen

    2018-07-01

    We exploited a novel sampling vehicle, a multi-rotor drone carrying a remote-controlled whole air sampling device, to collect aerial samples with high sample integrity and preservation conditions. An array of 106 volatile organic compounds (VOCs), CO, CH4, and CO2 were analyzed and compared between the aerial samples (300-m height) and the ground-level samples in pairs to inspect for vertical mixing of the trace gases at a coastal site under three different meteorological conditions of local circulation, frontal passage, and high-pressure peripheral circulation. A rather homogeneous composition was observed for the sample pairs immediately after the frontal passage, indicating a well-mixed condition below 300 m. In contrast, inhomogeneous mixing was observed for the sample pairs under the other two conditions (local circulation and high-pressure peripheral circulation), suggesting different layers of air masses. Furthermore, information of unique source markers, composition profiles, and lifetimes of compounds were used to differentiate the origins of the air masses aloft and at the surface to substantiate the observed inhomogeneity. The study demonstrates that, with the availability of the near-surface aerial sampling coupling with in-laboratory analysis, detailed compositions of trace gases can now be readily obtained with superior data quality. Based on the distinctive chemical compositions, the sources, transport, and atmospheric mixing of the airborne pollutants in the near-surface atmosphere can be better studied and understood.

  7. DESIGN, CONSTRUCTION, AND EVALUATION OF A CHAMBER FOR AEROBIOLOGY

    EPA Science Inventory

    A chamber was designed and constructed for aeromicrobiology applications. An ultraviolet (UV) radiation source was incorporated to sterilize the chamber between trials. Twelve bacterial species originally isolated from air samples and obtained from the American Type Culture Colle...

  8. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0005

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Humenik, F. M.

    1977-01-01

    Atmospheric ozone, water vapor, and related flight and meteorological data were obtained during 214 flights of a United Airlines B-747 and two Pan American World Airways B-747's from March through June 1976. In addition, trichlorofluoromethane data obtained from laboratory analysis of two whole air samples collected in flight are reported. These data are available on GASP tape VL0005 from the National Climatic Center, Asheville, North Carolina. In addition to the GASP data, tropopause pressure fields obtained from NMC archives for the dates of the GASP flights are included on the data tape. Flight routes and dates, instrumentation, data processing procedures, and data tape specifications are described in this report. Selected analyses including ozone and sample bottle data are also presented.

  9. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  10. Aerosol Sampling Experiment on the International Space Station

    NASA Technical Reports Server (NTRS)

    Meyer, Marit E.

    2017-01-01

    The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.

  11. Characterization of Ice Nucleating Particles at the Western US Coast

    NASA Astrophysics Data System (ADS)

    Rocci, K.; McCluskey, C. S.; Hill, T. C. J.; DeMott, P. J.; Kreidenweis, S. M.

    2015-12-01

    In temperate climates, ice nucleating particles (INPs) are vital for precipitation initiation. Because INPs may affect precipitation efficiency, and thereby the supply of water resources, it is paramount to have a clear understanding of both natural and anthropogenic sources of INPs. This is especially important to understand in California where drought continues to be a major problem. The CalWater 2015 field campaign, which took place in California from January 15 - March 9, 2015, included comprehensive characterizations of aerosols and their ice nucleating ability via ground-, air-, and ship-based measurements. As part of this campaign, we characterized and analyzed the intra-air mass differences of INPs at a coastal site (Bodega Bay) using immersion freezing measurements of particles collected on filters. Aerosol filters collected throughout the campaign were characterized by their loading and dominant type using meteorology, aerosol size distributions, aerosol composition, and trace gas concentration data. Samples contained a variety of aerosol influences, including biomass burning, nitrogen pollution, sulfur pollution, and sea spray. This study had a particular focus on the INP activity spectra of sea spray aerosol (SSA). We used the online aerosol data to infer variations in SSA types and heat-treated specific samples to look for the presence of heat-labile biological INPs. Furthermore, we ran the NOAA HYSPLIT model to obtain back trajectories for samples dominated by SSA. We found that air masses dominated by distinct terrestrial source types are not well distinguished by their INP number concentrations. However, we did see significantly higher (up to 5000-fold) INP number concentrations in SSA samples taken at the coast compared with number concentrations in samples obtained over open ocean. This difference could be attributable to differences in overall aerosol abundance, which will be evaluated in future studies. Overall, our findings suggest that an ocean-specific INP parameterization is needed for oceanic emissions and that terrestrial INP sources strongly impact the ice nucleating ability of marine boundary air.

  12. Complex permittivity measurements during high temperature recycling of space shuttle antenna window and dielectric heat shield materials

    NASA Technical Reports Server (NTRS)

    Bassett, H. L.; Bomar, S. H., Jr.

    1973-01-01

    The research performed and the data obtained on candidate space shuttle antenna window and heat shield materials are presented. The measurement technique employs a free-space focused beam microwave bridge for obtaining RF transmission data, and a device which rotates a sample holder which is heated on one side by natural gas-air flames. The surface temperature of each sample is monitored by IR pyrometry; embedded and rear surface thermocouples are also used in obtaining temperature data. The surface of the sample undergoing test is subjected to approximately the same temperature/time profile that occurs at a proposed antenna position on the space shuttle as it re-enters. The samples are cycled through ten of these temperature profiles to determine the recycling effects. Very little change was noted in the materials due to the recycling.

  13. Quantification of VOC emissions from paint spraying on a construction site using solid phase microextraction devices.

    PubMed

    Cheng, Wen-Hsi; Huang, Hsiao-Lin; Chen, Kang-Shin; Chang, Yu-Jen

    2017-10-15

    The objective of this study was to measure the emission of, and personal exposure to workers, volatile organic compound (VOC) during paint spraying on a construction site. Needle trap samplers (NTSs), which are a green solid phase microextraction sampling technology, were used to obtain air samples at a large music exhibition center. The standard active sampling method using charcoal tubes and a personal air pump, Method 1501, was simultaneously utilized at the sampling sites to assess the workers' VOC exposures. Analysis of the data thus obtained showed that benzene, toluene, ethylenebenzene, and xylenes (BTEXs) were the main emission compounds. Acetone and isobutyl alcohol, which are used as thinning solvents, were detected as minor emission compounds. The emitted concentrations of most compounds were lower than the legal emission limits in Taiwan except that of benzene, for which the 2-ppm time weighted average short-term exposure limit was exceeded. The packed divinylbenzene (DVB) in the NTS was observed under an environmental scanning electron microscope, and many fine aerosols were found to be deposited on the surface of the DVB adsorbents, causing VOC extraction efficiencies after the fifth sampling in the field to decline. Workers on construction sites should be protected from emissions of VOC and fine particulates to preserve their occupational health.

  14. Room temperature ferromagnetism in non-magnetic doped TiO2 nanoparticles

    NASA Astrophysics Data System (ADS)

    Gómez-Polo, C.; Larumbe, S.; Pastor, J. M.

    2013-05-01

    Room-temperature ferromagnetism in non-magnetic doped TiO2 semiconductor nanoparticles is analyzed in the present work. Undoped and N-doped TiO2 nanoparticles were obtained employing sol-gel procedure using urea as the nitrogen source. The obtained gels were first dried at 70 °C and afterwards calcined in air at 300 °C. A residual carbon concentration was retained in the samples as a consequence of the organic decomposition process. Post-annealing treatments at 300 °C under air and vacuum conditions were also performed. The crystallographic structure of nanoparticles was analyzed by X-ray diffraction, obtaining a single anatase crystalline phase after the calcinations (mean nanoparticle diameters around 5-8 nm). SQUID magnetometry was employed to analyze the magnetic response of the samples. Whereas for the undoped samples synthesized with hydrolysis rate h = 6, paramagnetic like behavior is observed at room temperature, the N-doped nanoparticles (h = 3) show a weak ferromagnetic response (saturation magnetization ≈10-3 emu/g). Moreover, a clear reinforcement of the room-temperature ferromagnetism response is found with the post-annealing treatments, in particular that performed in vacuum. Thus, the results indicate the dominant role of the oxygen stoichiometry and the oxygen vacancies in the room temperature ferromagnetic response of these TiO2 nanoparticles.

  15. Odour-causing compounds in air samples: gas-liquid partition coefficients and determination using solid-phase microextraction and GC with mass spectrometric detection.

    PubMed

    Godayol, Anna; Alonso, Mònica; Sanchez, Juan M; Anticó, Enriqueta

    2013-03-01

    A quantification method based on solid-phase microextraction followed by GC coupled to MS was developed for the determination of gas-liquid partition coefficients and for the air monitoring of a group of odour-causing compounds that had previously been found in wastewater samples including dimethyl disulphide, phenol, indole, skatole, octanal, nonanal, benzothiazole and some terpenes. Using a divinylbenzene/carboxen/polydimethylsiloxane fibre, adsorption kinetics have been studied to define an extraction time that would avoid coating saturation. It was found that for an extraction time of 10 min, external calibration could be performed in the range of 0.4-100 μg/m(3), with detection limits between 0.1 and 20 μg/m(3). Inter-day precision of the developed method was evaluated (n = 5) and RSD values between 12 and 24% were obtained for all compounds. The proposed method has been applied to the analysis of air samples surrounding a wastewater treatment plant in Catalonia (Spain). In all air samples evaluated, dimethyl disulphide, limonene and phenol were detected, and the first two were the compounds that showed the highest partition coefficients. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Modeling 3D conjugate heat and mass transfer for turbulent air drying of Chilean papaya in a direct contact dryer

    NASA Astrophysics Data System (ADS)

    Lemus-Mondaca, Roberto A.; Vega-Gálvez, Antonio; Zambra, Carlos E.; Moraga, Nelson O.

    2017-01-01

    A 3D model considering heat and mass transfer for food dehydration inside a direct contact dryer is studied. The k- ɛ model is used to describe turbulent air flow. The samples thermophysical properties as density, specific heat, and thermal conductivity are assumed to vary non-linearly with temperature. FVM, SIMPLE algorithm based on a FORTRAN code are used. Results unsteady velocity, temperature, moisture, kinetic energy and dissipation rate for the air flow are presented, whilst temperature and moisture values for the food also are presented. The validation procedure includes a comparison with experimental and numerical temperature and moisture content results obtained from experimental data, reaching a deviation 7-10 %. In addition, this turbulent k- ɛ model provided a better understanding of the transport phenomenon inside the dryer and sample.

  17. Tritium environmental transport studies at TFTR

    NASA Astrophysics Data System (ADS)

    Ritter, P. D.; Dolan, T. J.; Longhurst, G. R.

    1993-06-01

    Environmental tritium concentrations will be measured near the Tokamak Fusion Test Reactor (TFTR) to help validate dynamic models of tritium transport in the environment. For model validation the database must contain sequential measurements of tritium concentrations in key environmental compartments. Since complete containment of tritium is an operational goal, the supplementary monitoring program should be able to glean useful data from an unscheduled acute release. Portable air samplers will be used to take samples automatically every 4 hours for a week after an acute release, thus obtaining the time resolution needed for code validation. Samples of soil, vegetation, and foodstuffs will be gathered daily at the same locations as the active air monitors. The database may help validate the plant/soil/air part of tritium transport models and enhance environmental tritium transport understanding for the International Thermonuclear Experimental Reactor (ITER).

  18. Determination of methylamines in air using activated charcoal traps and gas chromatographic analysis with an alkali flame detector (AFD)

    NASA Astrophysics Data System (ADS)

    Fuselli, Sergio; Benedetti, Giorgio; Mastrangeli, Renato

    A method is described for trapping and analysing airborne methylamines (MMA, DMA and TMA) by means of a 20/35 mesh activated charcoal traps and subsequent GLSC analysis of collected sample using 0.1 N NaOH acqueous solution. The method described may be applied to monitoring methylamines in air in industrial areas, with an Alkali Flame Detector; sensitivities of approx. 0.005 ppmv for each of the three methylamines analysed are reached. Trapping efficiency is compared with that of Tenax GC 60/80 mesh and 60/80 Carbopack B which uses thermal desorption of air samples before GLSC analysis. The Tenax GC trap method enables TMA recovery only with a sensitivity of 0.0001 ppmv. Recovery obtained with 60/80 Carbopack B traps is practically zero.

  19. Can car air filters be useful as a sampling medium for air pollution monitoring purposes?

    PubMed

    Katsoyiannis, Athanasios; Birgul, Askin; Ratola, Nuno; Cincinelli, Alessandra; Sweetman, Andy J; Jones, Kevin C

    2012-11-01

    Urban air quality and real human exposure to chemical environmental stressors is an issue of high scientific and political interest. In an effort to find innovative and inexpensive means for air quality monitoring, the ability of car engine air filters (CAFs) to act as efficient samplers collecting street level air, to which people are exposed to, was tested. In particular, in the case of taxis, air filters are replaced after regular distances, the itineraries are almost exclusively urban, cruising mode is similar and, thus, knowledge of the air flow can provide with an integrated city air sample. The present pilot study focused on polycyclic aromatic hydrocarbons (PAHs), the most important category of organic pollutants associated with traffic emissions. Concentrations of ΣPAHs in CAFs ranged between 650 and 2900 μg CAF(-1), with benzo[b]fluoranthene, benzo[k]fluoranthene and indeno[123-cd]pyrene being the most abundant PAHs. Benzo[a]pyrene (BaP) ranged between 110 and 250 μg CAF(-1), accounting regularly for 5-15% of the total carcinogenic PAHs. The CAF PAH loads were used to derive road-level atmospheric PAH concentrations from a standard formula relating to the CAF air flow. Important parameters/assumptions for these estimates are the cruising speed and the exposure duration of each CAF. Based on information obtained from the garage experts, an average 'sampled air volume' of 48,750 m(3) per CAF was estimated, with uncertainty in this calculation estimated to be about a factor of 4 between the two extreme scenarios. Based on this air volume, ΣPAHs ranged between 13 and 56 ng m(-3) and BaP between 2.1 and 5.0 ng m(-3), suggesting that in-traffic BaP concentrations can be many times higher than the limit values set by the UK (0.25 ng m(-3)) and the European Union (1.0 ng m(-3)), or from active sampling stations normally cited on building roof tops or far from city centres. Notwithstanding the limitations of this approach, the very low cost, the continuous availability of very high amounts of "sample", and the "retroactivity" render it very useful and complementary to existing passive sampling techniques. This approach yields estimated air concentrations that reflect the pollutant concentrations to which taxi drivers, pedestrians, cyclists and road-related professionals are exposed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Bacterial Community in Water and Air of Two Sub-Alpine Lakes in Taiwan.

    PubMed

    Tandon, Kshitij; Yang, Shan-Hua; Wan, Min-Tao; Yang, Chia-Chin; Baatar, Bayanmunkh; Chiu, Chih-Yu; Tsai, Jeng-Wei; Liu, Wen-Cheng; Tang, Sen-Lin

    2018-04-21

    Very few studies have attempted to profile the microbial communities in the air above freshwater bodies, such as lakes, even though freshwater sources are an important part of aquatic ecosystems and airborne bacteria are the most dispersible microorganisms on earth. In the present study, we investigated microbial communities in the waters of two high mountain sub-alpine montane lakes-located 21 km apart and with disparate trophic characteristics-and the air above them. Although bacteria in the lakes had locational differences, their community compositions remained constant over time. However, airborne bacterial communities were diverse and displayed spatial and temporal variance. Proteobacteria, Actinobacteria, Bacteroidetes, and Cyanobacteria were dominant in both lakes, with different relative abundances between lakes, and Parcubacteria (OD1) was dominant in air samples for all sampling times, except two. We also identified certain shared taxa between lake water and the air above it. The results obtained on these communities in the present study provide putative candidates to study how airborne communities shape lake water bacterial compositions and vice versa.

  1. Effect of dry air on interface smoothening in reactive sputter deposited Co/Ti multilayer

    NASA Astrophysics Data System (ADS)

    Biswas, A.; Porwal, A.; Bhattacharya, Debarati; Prajapat, C. L.; Ghosh, Arnab; Nand, Mangla; Nayak, C.; Rai, S.; Jha, S. N.; Singh, M. R.; Bhattacharyya, D.; Basu, S.; Sahoo, N. K.

    2017-09-01

    Top surface roughness and interface roughness are one of the key elements which determine the performance of X-ray and neutron thin film multilayer devices. It has been observed that by mixing air with argon in sputtering ambience during deposition of Co layers, polarized neutron reflectivity (PNR) of Co/Ti supermirror polarizers can be improved substantially. Cross-sectional HRTEM measurement reveals that sharper interfaces in the supermirror can be achieved in case of deposition of the multilayer under mixed ambience of argon and air. In order to investigate this interface modification mechanism further, in this communication two sets of tri-layer Co/Ti/Co samples and 20-layer Co/Ti periodic multilayer samples have been prepared; in one set all the layers are deposited only under argon ambience and in the other set, Co layers are deposited under a mixed ambience of argon and air. These samples have been characterized by measuring specular and non-specular X-ray reflectivities (GIXR) with X-rays of 1.54 Å wavelength and polarized neutron reflectivity (PNR) with neutron of 2.5 Å wavelength at grazing angle of incidence. It has been observed that the X-ray and neutron specular reflectivities at Bragg peaks of 20 layer periodic multilayer increase when Co layers are deposited under mixed ambience of argon and air. The detail information regarding the effect of air on the interfaces and magnetic properties has been obtained by fitting the measured spectra. The above information has subsequently been supplemented by XRD and magnetic measurements on the samples. XPS and XANES measurements have also been carried out to investigate whether cobalt oxide or cobalt nitride layers are being formed due to use of air in sputtering ambience.

  2. C{sub 1}-C{sub 15} alkyl nitrates, benzyl nitrate, and bifunctional nitrates: Measurements in California and South Atlantic air and global comparison using C{sub 2}Cl{sub 4} and CHBr{sub 3} as marker molecules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, M.; Luxenhofer, O.; Deissler, A.

    1998-10-15

    Measurements of C{sub 1}--C{sub 15} alkyl nitrates, perchloroethylene, and bromoform at two different sampling sites near Santa Cruz, CA, were conducted in 1995. The halocarbons were used as marker molecules to differentiate the air parcels collected into marine and continental groups. The average concentration of {Sigma}n/i-C{sub 3}--C{sub 12} alkyl nitrates at the California Coast was lower than the levels obtained in the coastal mountains. This difference was shown to be most significant for the long chain n/i-C{sub 6}--C{sub 12} alkyl nitrates. It is concluded that the {ge}C{sub 6} alkyl nitrates in continental air can contribute 1--2% to the total NO{submore » y}. The results are summarized together with earlier data sets to give a picture of contemporary levels and of the global occurrence of C{sub 3}--C{sub 12} alkyl nitrates. In comparison with South Atlantic air, pattern analysis of n-alkyl nitrates suggests a marine source of primary n-alkyl nitrates. It is also shown that liquid chromatographic preseparation of the air sample extracts leads to a fraction that contains more polar organic nitrates. Several alkyl dinitrates and benzyl nitrate are detected in air samples from California, the South Atlantic region, and Europe. The vicinal alkyl dinitrates show increased abundance in a nighttime sample. The relative abundance of benzyl nitrate compared to alkyl (mono) nitrates is used as a tool for global air mass characterization.« less

  3. Estimating the change of porosity in the saturated zone during air sparging.

    PubMed

    Tsai, Yih-jin; Kuo, Yu-chia; Chen, Tsu-chi; Chou, Feng-chih

    2006-01-01

    Air sparging is a remedial method for groundwater. The remedial region is similar to the air flow region in the saturated zone. If soil particles are transported during air sparging, the porosity distributions in the saturated zone change, which may alter the flow path of the air. To understand better the particle movement, this study performed a sandbox test to estimate the soil porosity change during air sparging. A clear fracture was formed and the phenomenon of particle movement was observed when the air injection was started. The moved sand filled the porous around the fracture and the reparked sand filled the fracture, reducing the porosity around the fracture. The results obtained from the photographs of the sandbox, the current measurements and the direct sand sample measurements were close to each other and are credible. Therefore, air injection during air sparging causes sand particle movement of sand, altering the characteristic of the sand matrix and the air distribution.

  4. Investigation of air-entraining admixture dosage in fly ash concrete

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ley, M.T.; Harris, N.J.; Folliard, K.J.

    The amount of air-entraining admixture (AEA) needed to achieve a target air content in fresh concrete can vary significantly with differences in the fly ash used in the concrete. The work presented in this paper evaluates the ability to predict the AEA dosage on the basis of tests on the fly ash alone. All results were compared with the dosage of AEA required to produce an air content of 6% in fresh concrete. Fly ash was sampled from six separate sources. For four of these sources, samples were obtained both before and after the introduction of 'low-NOx burners'. Lack ofmore » definitive data about the coal itself or the specifics of the burning processes prevents the ability to draw specific conclusions about the impact of low-NOx burners on AEA demand. Nevertheless, the data suggest that modification of the burning process to meet environmental quality standards may affect the fly ash-AEA interaction.« less

  5. Heavy metals found in the breathing zone, toenails and lung function of welders working in an air-conditioned welding workplace.

    PubMed

    Hariri, Azian; Mohamad Noor, Noraishah; Paiman, Nuur Azreen; Ahmad Zaidi, Ahmad Mujahid; Zainal Bakri, Siti Farhana

    2017-09-22

    Welding operations are rarely conducted in an air-conditioned room. However, a company would set its welding operations in an air-conditioned room to maintain the humidity level needed to reduce hydrogen cracks in the specimen being welded. This study intended to assess the exposure to metal elements in the welders' breathing zone and toenail samples. Heavy metal concentration was analysed using inductively coupled plasma mass spectrometry. The lung function test was also conducted and analysed using statistical approaches. Chromium and manganese concentrations in the breathing zone exceeded the permissible exposure limit stipulated by Malaysian regulations. A similar trend was obtained in the concentration of heavy metals in the breathing zone air sampling and in the welders' toenails. Although there was no statistically significant decrease in the lung function of welders, it is suggested that exposure control through engineering and administrative approaches should be considered for workplace safety and health improvement.

  6. Assessment of indoor air quality exposures and impacts on respiratory outcomes in River Rouge and Dearborn, Michigan.

    PubMed

    Cleary, Erika; Asher, Mary; Olawoyin, Richard; Zhang, Kuangyuan

    2017-11-01

    Ambient air pollution is a public health issue which could potentially exacerbate pre-existing respiratory conditions and contribute to increases in asthma incidence. This study aims to address gaps in understanding how IAQ is impacted by outdoor air quality, which was done by sampling for indoor gaseous and particulate pollutants in residence and facilities near the sources of pollution. The study areas were selected due to non-attainment status with air quality standards, as well as demographic and socioeconomic status of those residing in these areas. Samples are obtained from five locations around the study areas. The sampling procedure involves active sampling methodologies for particulate matter (PM) and gases. Average volatile organic compounds (VOC) levels of 2.71 ppm were measured at a location, while the average particulate matter (PM) concentrations in three study locations were; 15,979 pt/cc, 9533 pt/cc, 5267 pt/cc respectively, which exceeded clean background environment level of 500-2000 pt/cc. All locations had average CO concentrations above 0.3 ppm, which is potentially associated with elevated asthma symptoms. Results demonstrated that facilities in the study area have increased levels of indoor air pollutants that potentially increase asthma and respiratory issues. The study concludes that particulate and gaseous pollutant levels in the study areas are a concerning human health issue. The study outcomes have significant implications for air quality exposure modeling and potential exposure mitigation strategies, which are expected to facilitate the implementation of public policies for improved human health conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Female Reproductive Effects of Exposure to Jet Fuel at U.S. Air Force Bases

    DTIC Science & Technology

    1998-11-01

    volunteers during 1997. Volunteers then provided feedback about the process and made suggestions for improvement. This information was used to develop...breath samples were processed in the field by collecting one (1) liter of expired breath in a Tedlar bag which was subsequently introduced onto a...also alert him when samples were obtained thru to menses. The process for returning samples was also facilitated by the provision of a mailing kit

  8. Distributions of SO2 and NO2 in the lower atmosphere of an industrial area in Bhutan.

    PubMed

    Subba, Jas Raj; Thammakhet, Chongdee; Thavarungkul, Panote; Kanatharana, Proespichaya

    2016-12-05

    Two important air pollutants, sulfur dioxide (SO 2 ) and nitrogen dioxide (NO 2 ), were sampled and monitored in the spring season in the biggest industrial area of Bhutan. Field measurements of SO 2 and NO 2 were performed using standard colorimetric methods, and air samples were collected using an active sampling technique. Sampling sites were selected to cover all the potential catchment areas like settlements, staff quarters, shops and schools. The main objective of this sampling work was to see the distribution of these two pollutants from the source of emission (small scale industries) and to obtain and establish a baseline data. The active sampler was first tested and validated in a laboratory using liquid and gas standards of SO 2 and NO 2 . Good linearity from 0.050 to 1.0 µg mL -1 for SO 2 and from 0.010 to 1.0 µg mL -1 for NO 2 were obtained (R 2 > 0.99) with limits of detection of 30 and 50 ng mL -1 for SO 2 and NO 2 , respectively. Daylong sampling was done at selected sites with a range of distances away from the sources of emission. The ambient concentration of SO 2 and NO 2 were in the range of 0.45-4.46 and 0.56-5.68 µg m -3 , respectively.

  9. Government employees' perception of urban air pollution and willingness to pay for improved quality: a cross-sectional survey study in Nanchang, China.

    PubMed

    Liu, Xiaojun; Wu, Yanyan; Hu, Yongxin; Liu, Denglai; Zhang, Jin; Chen, Cheng; Yuan, Zhaokang; Lu, Yuanan

    2016-11-01

    To improve the public's awareness of urban air pollution and promote establishment of more efficient policy toward urban air pollution, we investigated the government employees' perceptions of current urban air pollution and their willingness to pay (WTP) taxes for improved quality in Nanchang, China. Stratified cluster sampling strategy was used to distribute 629 questionnaires, and 608 were completed anonymously, yielding a 96.7 % response rate. Descriptive statistics frequencies and proportions were used to summarize the sample characteristics, and logistic regression models were performed to assess the associations of perception of urban air quality and WTP versus demographic variables. We found low awareness of urban air pollution (34.5 %) as well as low WTP (44.9 %), especially among the middle aged people (age 30-39 and age 40-49). Our study shows that female employees have better awareness of urban air pollution but much less willingness to pay for air quality improvement. Majority of the government employees showed their support to the government for more effective policies toward environmental protection, indicating more enhanced public education and environmental protection campaigns to improve the public's awareness of air pollution and work with every citizen to improve air quality. This study also obtained baseline information useful to the local regional and even national government in developing nations in their attempt to control urban air pollution in future.

  10. Distribution and prevalence of airborne microorganisms in three commercial poultry processing plants.

    PubMed

    Whyte, P; Collins, J D; McGill, K; Monahan, C; O'Mahony, H

    2001-03-01

    Airborne microbial contaminants and indicator organisms were monitored within three poultry processing plants (plants A, B, and C). In total, 15 cubic feet (c.f.) of air was sampled per location during 15 visits to each plant and quantitatively analyzed for total mesophilic and psychrophilic aerobic counts, thermophilic campylobacters, Escherichia coli, and Enterobacteriaceae. The prevalence of Salmonella spp. in air samples was also evaluated. Significant reductions in total aerobic counts were observed between defeathering and evisceration areas of the three plants (P < 0.05). Mesophilic plate counts were highest in the defeathering areas of all plants compared to equivalent psychrophilic plate counts. Enterobacteriaceae counts were highest in the defeathering areas of all three plants with counts of log10 1.63, 1.53, and 1.18 CFU/15 c.f. recovered in plants A, B, and C, respectively. E. coli enumerated from air samples in the defeathering areas exhibited a similar trend to those obtained for Enterobacteriaceae with log10 1.67, 1.58, and 1.18 CFU for plants A, B, and C, respectively. Thermophilic campylobacters were most frequently isolated from samples in the defeathering areas followed by the evisceration areas. The highest mean counts of the organism were observed in plant A at 21 CFU/15 c.f. sample with plants B and C at 9 and 8 CFU/sample, respectively. With the exception of low levels of Enterobacteriaceae recovered from samples in the on-line air chill in plant A, E. coli, Enterobacteriaceae, or Campylobacter spp. were not isolated from samples in postevisceration sites in any of the plants examined. Salmonella spp. were not recovered from any samples during the course of the investigation.

  11. The Adoption of Technological Innovations by Municipal Governments.

    ERIC Educational Resources Information Center

    Feller, Irwin; Menzel, Donald C.

    1978-01-01

    Data on the adoption of 43 technological innovations in four service delivery areas were obtained from nationally representative samples of municipal governments. The service delivery areas included fire fighting, solid waste collection and disposal, traffic control, and air pollution control. (Author/RLV)

  12. Characterization of VOC Emissions from Various Components of Dairy Farming and their effect on San Joaquin Valley Air Quality

    NASA Astrophysics Data System (ADS)

    Yang, M. M.; Meinardi, S.; Krauter, C.; Blake, D.

    2008-12-01

    The San Joaquin Valley Air Basin in Central California is classified by the U.S. Environmental Protection Agency (EPA) as a serious non-attainment area for health-based eight-hour federal ozone (smog) standard (1). In August 2005, the San Joaquin Valley Air Pollution Control District issued a report identifying dairies as a main source of Volatile Organic Compounds (VOCs) and fine particulate matter in the valley (2). Among these compounds, we have found that ethanol, methanol, acetone and acetaldehyde are produced in major quantities throughout the San Joaquin valley as by-products of yeast fermentation of silage and photochemical oxidation. These oxygenates, especially ethanol, play an important role in ozone (O3) formation within the valley. Three different types of sampling protocols were employed in order to determine the degree of enhancement of the four oxygenates in the valley air shed, as well as to determine their sources, emission profiles and emission rates. An assessment of the emissions of these oxygenates in the valley was achieved using data obtained on low altitude flights through the valley and from ground level samples collected thoughout the valley. The photochemical production of ozone was calculated for each of the four oxygenates and approximately one hundred other quantified VOCs. Based on the Maximum Incremental Reactivity (MIR) scale and concentrations of each oxygenate in the atmosphere, as much as 20% of O3 production in the valley is from ethanol and its photochemical by-product acetaldehyde. Our findings suggest that improvement to the valley air quality may be obtained by focusing on instituting new silage containment practices and regulations. 1. Lindberg, J. "Analysis of the San Joaquin Valley 2007 Ozone Plan." State of California Air Resources Board. Final Draft Staff Report. 5/30/2007. 2. Crow, D., executive director/APCO. "Air Pollution Control Officer's Determination of VOC Emisison Factors for Dairies." San Joaquin Valley Air Pollution Control District. Aug. 1st 2005.

  13. Air permeability and trapped-air content in two soils

    USGS Publications Warehouse

    Stonestrom, David A.; Rubin, Jacob

    1989-01-01

    To improve understanding of hysteretic air permeability relations, a need exists for data on the water content dependence of air permeability, matric pressure, and air trapping (especially for wetting-drying cycles). To obtain these data, a special instrument was designed. The instrument is a combination of a gas permeameter (for air permeability determination), a suction plate apparatus (for retentivity curve determination), and an air pycnometer (for trapped-air-volume determination). This design allowed values of air permeability, matric pressure, and air trapping to be codetermined, i.e., determined at the same values of water content using the same sample and the same inflow-outflow boundaries. Such data were obtained for two nonswelling soils. The validity of the air permeability determinations was repeatedly confirmed by rigorous tests of Darcy's law. During initial drying from complete water saturation, supplementary measurements were made to assess the magnitude of gas slip. The extended Darcy equation accurately described the measured flux gradient relations for each condition of absolute gas pressure tested. Air permeability functions exhibited zero-permeability regions at high water contents as well as an abruptly appearing hysteresis at low water contents. Measurements in the zero-permeability regions revealed that the total amount of air in general exceeded the amount of trapped air. This indicates that the medium' s air space is partitioned into three measurable domains: through-flowing air, locally accessible air (i.e., air accessible from only one flow boundary), and trapped air. During repeated wetting and drying, the disappearance and reappearance of air permeability coincided closely with the reappearance and disappearance, respectively, of trapped air. The observed relation between critical features of the air permeability functions and those of the air-trapping functions suggest that water-based blockages play a significant role in the disruption of gas-phase connectivity and in preventing air flow, and must be considered in any effectual model of air permeability relations.

  14. Analysis of Near-Surface Oceanic Measurements Obtained During the Low-Wind Component of the Coupled Boundary Layers and Air-Sea Transfer (CBLAST) Experiment

    DTIC Science & Technology

    2006-09-30

    temperature and the upwelling IR radiative heat flux were obtained from a pyrometer . The heat fluxes are combined to compute the net heat flux into or out...sampled acoustic Doppler velocimeters (ADVs) and thermistors (Figure 1b). These measurements provide inertial-range estimates of dissipation rates...horizontal velocity at the sea surface were obtained with a “fanbeam” acoustic Doppler current profiler (ADCP), which produces spatial maps of the

  15. In-air PIXE analysis by means of glass capillary optics

    NASA Astrophysics Data System (ADS)

    Nebiki, Takuya; Kabir, M. Hasnat; Narusawa, Tadashi

    2006-08-01

    A novel technique to introduce high energy ion beams to atmospheric environment is presented, which enables in-air PIXE measurements. Slightly tapered glass capillary optics is applied to work as a differential pumping orifice as well as a focusing lens. The flux intensity is enhanced by at least one order of magnitude due to the focusing effect. Using capillaries of 10-20 μm outlet diameters, we obtain several hundreds pA of 4 MeV He2+ ion beam and apply it to PIXE analysis of the seabed sludge without any sample treatments. A comparison of spectra between wet and dry sludge samples suggests the usefulness of our new technique.

  16. Comparison of passive diffusion bag samplers and submersible pump sampling methods for monitoring volatile organic compounds in ground water at Area 6, Naval Air Station, Whidbey Island, Washington

    USGS Publications Warehouse

    Huffman, Raegan L.

    2002-01-01

    Ground-water samples were collected in April 1999 at Naval Air Station Whidbey Island, Washington, with passive diffusion samplers and a submersible pump to compare concentrations of volatile organic compounds (VOCs) in water samples collected using the two sampling methods. Single diffusion samplers were installed in wells with 10-foot screened intervals, and multiple diffusion samplers were installed in wells with 20- to 40-foot screened intervals. The diffusion samplers were recovered after 20 days and the wells were then sampled using a submersible pump. VOC concentrations in the 10-foot screened wells in water samples collected with diffusion samplers closely matched concentrations in samples collected with the submersible pump. Analysis of VOC concentrations in samples collected from the 20- to 40-foot screened wells with multiple diffusion samplers indicated vertical concentration variation within the screened interval, whereas the analysis of VOC concentrations in samples collected with the submersible pump indicated mixing during pumping. The results obtained using the two sampling methods indicate that the samples collected with the diffusion samplers were comparable with and can be considerably less expensive than samples collected using a submersible pump.

  17. Atmospheric CH4 Concentrations from the Commonwealth Scientific and Industrial Research Organization (CSIRO) GASLAB Flask Sampling Network (1984 - 2001)

    DOE Data Explorer

    Steele, L. P. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Krummel, P. B. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Langenfelds, R. L. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia

    2003-01-01

    The listed data were obtained from flask air samples returned to the CSIRO GASLAB for analysis. Typical sample storage times ranged from days to weeks for some sites (e.g., Cape Grim) to as much as one year for Macquarie Island and the Antarctic sites. Experiments carried out to test for any change in sample CH4 mixing ratio during storage have shown no drift to within detection limits over test periods of several months to years (Cooper et al., 1999).

  18. Determination of a wide range of volatile organic compounds in ambient air using multisorbent adsorption/thermal desorption and gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Pankow, J.F.; Luo, W.; Isabelle, L.M.; Bender, D.A.; Baker, R.J.

    1998-01-01

    Adsorption/thermal desorption with multisorbent air-sampling cartridges was developed for the determination of 87 method analytes including halogenated alkanes, halogenated alkenes, ethers, alcohols, nitriles, esters, ketones, aromatics, a disulfide, and a furan. The volatilities of the compounds ranged from that of dichlorofluoromethane (CFC12) to that of 1,2,3- trichlorobenzene. The eight most volatile compounds were determined using a 1.5-L air sample and a sample cartridge containing 50 mg of Carbotrap B and 280 mg of Carboxen 1000; the remaining 79 compounds were determined using a 5-L air sample and a cartridge containing 180 mg of Carbotrap B and 70 mg of Carboxen 1000. Analysis and detection were by gas chromatography/mass spectrometry. The minimum detectable level (MDL) concentration values ranged from 0.01 parts per billion by volume (ppbv) for chlorobenzene to 0.4 ppbv for bromomethane; most of the MDL values were in the range 0.02-0.06 ppbv. No breakthrough was detected with the prescribed sample volumes. Analyte stability on the cartridges was very good. Excellent recoveries were obtained with independent check standards. Travel spike recoveries ranged from 90 to 110% for 72 of the 87 compounds. The recoveries were less than 70% for bromomethane and chloroethene and for a few compounds such as methyl acetate that are subject to losses by hydrolysis; the lowest travel spike recovery was obtained for bromomethane (62%). Blank values for all compounds were either below detection or very low. Ambient atmospheric sampling was conducted in New Jersey from April to December, 1997. Three sites characterized by low, moderate, and high densities of urbanization/traffic were sampled. The median detected concentrations of the compounds were either similar at all three sites (as with the chlorofluorocarbon compounds) or increased with the density of urbanization/traffic (as with dichloromethane, MTBE, benzene, and toluene). For toluene, the median detected concentrations were 0.23, 0.42, and 0.70 ppbv at the three sites. Analytical precision was measured using duplicate sampling. As expected, the precision deteriorated with decreasing concentration. At concentrations greater than 0.2 ppbv, most duplicates differed by less than 20%; below the MDL values, the differences between the duplicates were larger, but they were still typically less than 40%.

  19. Synthetic Reference Materials Based on Polymer Films for the Control of Welding Fumes Composition

    NASA Astrophysics Data System (ADS)

    Kuznetsova, O. V.; Kuznetsova, A. N.; Begunova, L. A.

    2017-04-01

    Analysis of the current hygienic situation in the welding production showed that the intensification of welding processes involves the deterioration of air quality, which negatively affects the welders health. Welders are exposed to a variety of metal fumes, including manganese that may elevate the risk for neurological diseases. The control of metals concentration in the air of the working area is difficult due to the lack of reference materials. The creation of reference materials of welding fumes composition is a challenge due to chemical characteristics of their physical properties. Synthetic samples in a form of the polymer film containing powder particles of welding fumes were create. Studies on the selection of the polymer were done. Experiments proved that the qualitative materials of synthetic welding fumes are obtained by using polyvinyl alcohol. The metals concentration in the samples was determined by X-ray fluorescence analysis. The obtained data demonstrates indirectly the uniform distribution of welding fumes powder particles on the polymer film.

  20. Extraction studies. Final report, May 6, 1996--September 30, 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    During the first week of this effort, an Alpkem RFA-300 4-channel automated chemical analyzer was transferred to the basement of building 42 at TA-46 for the purpose of performing extraction studies. Initially, this instrumentation was applied to soil samples known to contain DNA. Using the SFA (Segmented Flow Analysis) technique, several fluidic systems were evaluated to perform on-line filtration of several varieties of soil obtained from Cheryl Kuske and Kaysie Banton (TA-43, Bldg. 1). Progress reports were issued monthly beginning May 15, 1996. Early in 1997 there was a shift from the conventional 2-phase system (aqueous + air) to amore » 3-phase system (oil + aqueous + air) to drastically reduce sample size and reagent consumption. Computer animation was recorded on videotape for presentations. The time remaining on the subcontract was devoted to setting up existing equipment to incorporate the 3rd phase (a special fluorocarbon oil obtained from DuPont).« less

  1. Indoor air bacterial load and antibiotic susceptibility pattern of isolates in operating rooms and surgical wards at jimma university specialized hospital, southwest ethiopia.

    PubMed

    Genet, Chalachew; Kibru, Gebre; Tsegaye, Wondewosen

    2011-03-01

    Surgical site infection is the second most common health care associated infection. One of the risk factors for such infection is bacterial contamination of operating rooms' and surgical wards' indoor air. In view of that, the microbiological quality of air can be considered as a mirror of the hygienic condition of these rooms. Thus, the objective of this study was to determine the bacterial load and antibiotic susceptibility pattern of isolates in operating rooms' and surgical wards' indoor air of Jimma University Specialized Hospital. A cross sectional study was conducted to measure indoor air microbial quality of operating rooms and surgical wards from October to January 2009/2010 on 108 indoor air samples collected in twelve rounds using purposive sampling technique by Settle Plate Method (Passive Air Sampling following 1/1/1 Schedule). Sample processing and antimicrobial susceptibility testing were done following standard bacteriological techniques. The data was analyzed using SPSS version 16 and interpreted according to scientifically determined baseline values initially suggested by Fisher. The mean aerobic colony counts obtained in OR-1(46cfu/hr) and OR-2(28cfu/hr) was far beyond the set 5-8cfu/hr acceptable standards for passive room. Similarly the highest mean aerobic colony counts of 465cfu/hr and 461cfu/hr were observed in Female room-1 and room-2 respectively when compared to the acceptable range of 250-450cfu/hr. In this study only 3 isolates of S. pyogenes and 48 isolates of S. aureus were identified. Over 66% of S. aureus was identified in Critical Zone of Operating rooms. All isolates of S. aureus showed 100% and 82.8% resistance to methicillin and ampicillin respectively. Higher degree of aerobic bacterial load was measured from operating rooms' and surgical wards' indoor air. Reducing foot trafficking, improving the ventilation system and routine cleaning has to be made to maintain the aerobic bacteria load with in optimal level.

  2. An Investigation of Air Quality Surrounding Lake Merritt in Oakland, California

    NASA Astrophysics Data System (ADS)

    Ararso, I.; Casino, N.; Chen, B.; Johnson, J.; Koerber, K. W.; Lau, S.; Truisi, V.; Yanez, M.; Yeung, A.; Unigarro, M.; Vue, G.; Garduno, L.; Cuff, K.

    2005-12-01

    Lake Merritt is a naturally occurring inlet from the San Francisco Bay that was converted into an urban lake near downtown Oakland in 1860. The Lake itself is located within the Lake Merritt Park and Wildlife Refuge, home to over 90 species of migrating waterfowl, as well as a variety of aquatic wildlife. Its close proximity to downtown, several busy roads, and two major highways makes Lake Merritt a popular destination that is easily accessible to Oakland residents, but also puts it at risk for impaired air quality due to automobile exhaust. In an effort to assess air quality near Lake Merritt, we measured percent oxygen and carbon dioxide (CO2) concentrations in ambient air. These two gases can be used to assess air quality because the significant build up of CO2, which primarily results from the incomplete combustion of personal automobile engines, can result in the reduction of oxygen to concentration levels that are hazardous to human and other life. During the Summer of 2005, air samples from over 90 different locations were collected and used to make these measurements. Measurements were made with PASCO data-loggers attached to sensors that use infrared detectors to measure the amount of energy absorbed by carbon dioxide and oxygen molecules. Results were statistically analyzed, mapped, and used to assess the overall quality of air surrounding the Lake. Preliminary analysis of oxygen data indicates that higher concentration levels occur near sections of the Lake that are furthest removed from major roads, as well as in areas that have significant amounts of vegetation. In fact, the highest value recorded in this study was measured in a sample obtained near a grove of trees in a portion of the park that has the most vegetation, and that is furthest removed from major roads. Air quality here is high primarily due to the absence of CO2 build up associated with automobile traffic. The lowest values recorded were measured in samples collected along a stretch of the lakeshore that is very close to one of the busiest streets in the general area. The general trend of carbon dioxide concentration levels was also observed to decrease with distance from major roads and nearby highways. In the future, we plan to investigate possible relationships between oxygen and carbon dioxide concentrations in air surrounding the Lake and dissolved oxygen concentration of its waters. To the best of our knowledge, the air quality surrounding Lake Merritt has not been investigated before. Therefore results obtained during this study provide the foundation upon which future research may be built.

  3. First 2 years of Atmospheric CO2 measurements in the Estany Llong plain (2100 masl, Parc Nacional d'Aigüestortes i Estany de Sant Maurici, Pyrenees, Catalonia, Spain).

    NASA Astrophysics Data System (ADS)

    Curcoll, Roger; Recolons, Montserrat; Font, Anna; Agraz, Laura; Parga, Elena; Bacardit, Montse; Camarero, Lluís.; Pueyo, Salva; Rodó, Xavier; Morguí, Josep Anton

    2010-05-01

    Since April 2009, air samples are being taken bi-weekly at 10 GMT in the plain of the Estany Llong at 2100 masl. Estany Llong air sampling site (ELL, 42°34'29''N 0°57'17''E) is a remote site situated in the SW principal valley of the Parc Nacional d'Aigüestortes i Estany de Sant Maurici. New Flask-sampling equipment for Remote Mountain Sites was developed by the Institut Català de Ciències del Clima (IC3) to allow flask sampling in extreme weather conditions and carrying the sampling equipment for more than 10 km without damaging flasks. Dry Air analysis for CO2 are done at the Laboratory of IC3 using two coupled modified IRGA Licor-7000, where both pressure and flow are externally controlled. Far away from populated areas, ELL site acts as a remote site, but it is also responding to discrete events as snow melting, summer cattle breeding on pastures and trekking frequentation. Series of CO2 obtained are included as part of Long Term Ecological Research (LTER) at the Parc Nacional d'Aigüestortes i Estany de Sant Maurici. In the long term, these measurements show the mountain ecosystems contribution and geomorphologic influence on the CO2 budget of the air masses crossing a mountain range.

  4. Documentation and environment of the Apollo 16 samples: A preliminary report

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A catalog which is a working document that shows the locations from which samples were collected during the Apollo 16 mission, and that provides a descriptive geologic context for each sample is presented. It is a compilation of notes from work in progress, and supersedes an earlier report prepared by the Apollo Lunar Geology Investigation Team. The information was obtained from the Air-to-Ground transcript from the astronaut crew, from lunar surface television, from 60 mm Hasselblad camera photographs, and from available LRL mugshot photographs of the samples. The sample descriptions are based on these sources of data.

  5. Environmental survey to assess viral contamination of air and surfaces in hospital settings.

    PubMed

    Carducci, A; Verani, M; Lombardi, R; Casini, B; Privitera, G

    2011-03-01

    The presence of pathogenic viruses in healthcare settings represents a serious risk for both staff and patients. Direct viral detection in the environment poses significant technical problems and the indirect indicators currently in use suffer from serious limitations. The aim of this study was to monitor surfaces and air in hospital settings to reveal the presence of hepatitis C virus, human adenovirus, norovirus, human rotavirus and torque teno virus by nucleic acid assays, in parallel with measurements of total bacterial count and haemoglobin presence. In total, 114 surface and 62 air samples were collected. Bacterial contamination was very low (<1 cfu/cm(2)) on surfaces, whereas the 'medium' detected value in air was 282 cfu/m(3). Overall, 19 (16.7%) surface samples tested positive for viral nucleic acids: one for norovirus, one for human adenovirus and 17 (14.9%) for torque teno virus (TTV). Only this latter virus was directly detected in 10 air samples (16.1%). Haemoglobin was found on two surfaces. No relationship was found between viral, biochemical or bacterial indicators. The data obtained confirm the difficulty of assessing viral contamination using bacterial indicators. The frequent detection of TTV suggests its possible use as an indicator for general viral contamination of the environment. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  6. Characterisation of Arctic Bacterial Communities in the Air above Svalbard

    PubMed Central

    Cuthbertson, Lewis; Amores-Arrocha, Herminia; Malard, Lucie A.; Els, Nora; Sattler, Birgit; Pearce, David A.

    2017-01-01

    Atmospheric dispersal of bacteria is increasingly acknowledged as an important factor influencing bacterial community biodiversity, biogeography and bacteria–human interactions, including those linked to human health. However, knowledge about patterns in microbial aerobiology is still relatively scarce, and this can be attributed, in part, to a lack of consensus on appropriate sampling and analytical methodology. In this study, three different methods were used to investigate aerial biodiversity over Svalbard: impaction, membrane filtration and drop plates. Sites around Svalbard were selected due to their relatively remote location, low human population, geographical location with respect to air movement and the tradition and history of scientific investigation on the archipelago, ensuring the presence of existing research infrastructure. The aerial bacterial biodiversity found was similar to that described in other aerobiological studies from both polar and non-polar environments, with Proteobacteria, Actinobacteria, and Firmicutes being the predominant groups. Twelve different phyla were detected in the air collected above Svalbard, although the diversity was considerably lower than in urban environments elsewhere. However, only 58 of 196 bacterial genera detected were consistently present, suggesting potentially higher levels of heterogeneity. Viable bacteria were present at all sampling locations, showing that living bacteria are ubiquitous in the air around Svalbard. Sampling location influenced the results obtained, as did sampling method. Specifically, impaction with a Sartorius MD8 produced a significantly higher number of viable colony forming units (CFUs) than drop plates alone. PMID:28481257

  7. New approach to resolve the humidity problem in VOC determination in outdoor air samples using solid adsorbent tubes followed by TD-GC-MS.

    PubMed

    Maceira, Alba; Vallecillos, Laura; Borrull, Francesc; Marcé, Rosa Maria

    2017-12-01

    This study describes the humidity effect in the sampling process by adsorbent tubes followed by thermal desorption and gas chromatography-mass spectrometry (TD-GC-MS) for the determination of volatile organic compounds (VOCs) in air samples and evaluates possible solutions to this problem. Two multi-sorbent bed tubes, Tenax TA/Carbograph 1TD and Carbotrap B/Carbopack X/Carboxen 569, were tested in order to evaluate their behaviour in the presence of environmental humidity. Humidity problems were demonstrated with carbon-based tubes, while Tenax-based tubes did not display any influence. Silica gel, a molecular sieve and CaCl 2 were tried out as materials for drying tube to remove air humidity, placed prior to the sampling tube to prevent water from entering. The pre-tubes filled with 0.5g of CaCl 2 showed the best results with respect to their blanks, the analytes recoveries and their ability to remove ambient humidity. To avoid the possible agglomeration of CaCl 2 during the sampling process in high relative humidity atmospheres, 0.1g of diatomaceous earth were mixed with the desiccant agent. The applicability of the CaCl 2 pre-tube as drying agent prior to Carbotrap B/Carbopack X/Carboxen 569 tubes was tested in urban and industrial locations with samplings of air at high relative humidity. In addition, the results were compared with those obtained using Tenax TA/Carbograph 1TD tubes. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Assessment of atmospheric distribution of polycyclic aromatic hydrocarbons using a molecular structure model

    NASA Astrophysics Data System (ADS)

    Turk Sekulić, Maja; Okuka, Marija; Šenk, Nevena; Radonić, Jelena; Vojinović Miloradov, Mirjana; Vidicki, Branko

    2013-07-01

    In this paper, a comparison of experimentally obtained and SPARC software v4.6 modelled values of gas/particle partitioning coefficients was conducted to determine whether the evaluation of atmospheric distribution of PAH molecules can be performed using a molecular structure model. Partitioning coefficients were calculated for sixteen EPA PAHs, in thirty-nine samples of ambient air collected at nineteen urban, industrial, highly contaminated and background sites in the Republic of Serbia and Bosnia and Herzegovina. For obtaining samples of ambient air, the conventional high volume (Hi-Vol) methodology was applied, whereby gaseous and particulate phase data collection was conducted simultaneously by glass fibre filters (GFFs) and polyurethane foam filters (PUFs). The best prediction was for PAHs with 5 or more rings (benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, indeno(1,2,3-cd)perylene and benzo(ghi)perylene). For evaluating the applicability of SPARC software predictions of gas/particle partitioning coefficients for the existing conditions, the results were compared with those obtained by applying other frequently used and highly ranked theoretical models of phase distributions, namely Junge-Pankow adsorption model, KOA absorption model, Dachs-Eisenreich dual model and PP-LFER model.

  9. Indoor air pollution evaluation with emphasize on HDI and biological assessment of HDA in the polyurethane factories.

    PubMed

    Mirmohammadi, Mirtaghi; Hakimi Ibrahim, M; Ahmad, Anees; Kadir, Mohd Omar Abdul; Mohammadyan, M; Mirashrafi, S B

    2010-06-01

    Today, many raw materials used in factories may have a dangerous effect on the physiological system of workers. One of them which is widely used in the polyurethane factories is diisocyanates. These compounds are widely used in surface coatings, polyurethane foams, adhesives, resins, elastomers, binders, and sealants. Exposure to diisocyanates causes irritation to the skin, mucous membranes, eyes, and respiratory tract. Hexamethylene diamine (HDA) is metabolite of hexamethylene diisocyanate (HDI). It is an excretory material by worker's urine who is exposed to HDI. Around 100 air samples were collected from five defined factories by midget impinger which contained dimethyl sulfoxide absorbent as a solvent and tryptamine as reagent. Samples were analyzed by high-performance liquid chromatography with EC\\UV detector using NIOSH 5522 method of sampling. Also, 50 urine samples collected from workers were also analyzed using William's biological analysis method. The concentration of HDI into all air samples were more than 88 microg/m(3), and they have shown high concentration of pollutant in the workplaces in comparison with NIOSH standard, and all of the workers' urine were contaminated by HDA. The correlation and regression test were used to obtain statistical model for HDI and HDA, which is useful for the prediction of diisocyanates pollution situation in the polyurethane factories.

  10. Concentration and characteristics of depleted uranium in water, air and biological samples collected in Serbia and Montenegro.

    PubMed

    Jia, Guogang; Belli, Maria; Sansone, Umberto; Rosamilia, Silvia; Gaudino, Stefania

    2005-09-01

    During the Balkan conflicts, in 1995 and 1999, depleted uranium (DU) rounds were employed and were left in the battlefield. Health concern is related to the risk arising from contamination of the environment with DU penetrators and dust. In order to evaluate the impact of DU on the environment and population in Serbia and Montenegro, radiological surveys of DU in water, air and biological samples were carried out over the period 27 October-5 November 2001. The uranium isotopic concentrations in biological samples collected in Serbia and Montenegro, mainly lichens and barks, were found to be in the range of 0.67-704 Bqkg(-1) for (238)U, 0.48-93.9 Bqkg(-1) for (234)U and 0.02-12.2 Bqkg(-1) for (235)U, showing uranium levels to be higher than in the samples collected at the control sites. Moreover, (236)U was detectable in some of the samples. The isotopic ratios of (234)U/(238)U showed DU to be detectable in many biological samples at all examined sites, especially in Montenegro, indicating widespread ground-surface DU contamination, albeit at very low level. The uranium isotopic concentrations in air obtained from the air filter samples collected in Serbia and Montenegro were found to be in the range of 1.99-42.1 microBqm(-3) for (238)U, 0.96-38.0 microBqm(-3) for (234)U, and 0.05-1.83 microBqm(-3) for (235)U, being in the typical range of natural uranium values. Thus said, most of the air samples are DU positive, this fact agreeing well with the widespread DU contamination detected in the biological samples. The uranium concentrations in water samples collected in Serbia and Montenegro were found to be in the range of 0.40-21.9 mBql(-1) for (238)U, 0.27-28.1 mBql(-1) for (234)U, and 0.01-0.88 mBql(-1) for (235)U, these values being much lower than those in mineral water found in central Italy and below the WHO guideline for drinking water. From a radiotoxicological point of view, at this moment there is no significant radiological risk related to these investigated sites in terms of possible DU contamination of water, air and/or plants.

  11. A single-blind controlled study of electrocautery and ultrasonic scalpel smoke plumes in laparoscopic surgery.

    PubMed

    Fitzgerald, J Edward F; Malik, Momin; Ahmed, Irfan

    2012-02-01

    Surgical smoke containing potentially carcinogenic and irritant chemicals is an inevitable consequence of intraoperative energized dissection. Different energized dissection methods have not been compared directly in human laparoscopic surgery or against commonly encountered pollutants. This study undertook an analysis of carcinogenic and irritant volatile hydrocarbon concentrations in electrocautery and ultrasonic scalpel plumes compared with cigarette smoke and urban city air control samples. Once ethical approval was obtained, gas samples were aspirated from the peritoneal cavity after human laparoscopic intraabdominal surgery solely using either electrocautery or ultrasonic scalpels. All were adsorbed in Tenax tubes and concentrations of carcinogenic or irritant volatile hydrocarbons measured by gas chromatography. The results were compared with cigarette smoke and urban city air control samples. The analyzing laboratory was blinded to sample origin. A total of 10 patients consented to intraoperative gas sampling in which only one method of energized dissection was used. Six carcinogenic or irritant hydrocarbons (benzene, ethylbenzene, styrene, toluene, heptene, and methylpropene) were identified in one or more samples. With the exception of styrene (P = 0.016), a nonsignificant trend toward lower hydrocarbon concentrations was observed with ultrasonic scalpel use. Ultrasonic scalpel plumes had significantly lower hydrocarbon concentrations than cigarette smoke, with the exception of methylpropene (P = 0.332). No significant difference was observed with city air. Electrocautery samples contained significantly lower hydrocarbon concentrations than cigarette smoke, with the exception of toluene (P = 0.117) and methyl propene (P = 0.914). Except for toluene (P = 0.028), city air showed no significant difference. Both electrocautery and ultrasonic dissection are associated with significantly lower concentrations of the most commonly detected carcinogenic and irritant hydrocarbons than cigarette smoke. A nonsignificant trend toward lower hydrocarbon concentrations was seen with ultrasonic scalpel dissection compared with diathermy. The contamination levels in city air were largely comparable with those seen after ultrasonic scalpel use. Although hydrocarbon concentrations are low, cumulative exposures may increase health risks. Where concerns arise, ultrasonic scalpel dissection may be preferable.

  12. Bacteriological evaluation of a down-draught necropsy table ventilation system.

    PubMed

    al-Wali, W; Kibbler, C C; McLaughlin, J E

    1993-08-01

    To evaluate the microbiological efficacy of a down-draught necropsy table ventilation system (which surrounds the cadaver with a "curtain" of air under continuous extraction) during post mortem procedures. Air sampling was carried out both in the presence and absence of staff and cadaver and during a full post mortem procedure, with functioning and non-functioning table air extraction. The penetration of the air "curtain" was also examined during the use of an oscillating bone saw by means of a tracer organism, Bacillus subtilis var niger, painted on to the skull. There was little difference between bacterial counts obtained in the presence of staff only, staff plus cadaver, or during a post mortem examination. With all counts obtained, however, there was a two to three-fold reduction when the ventilation was in operation compared with when the extract duct was occluded. Using the tracer organism, a two to three log reduction in counts was shown when the "curtain" was in operation during the use of the oscillating bone saw. These results suggest that the system provides potential protection for post mortem room staff against airborne infections.

  13. Can We Monitor Ecosystem Function Using Keeling Plot Analyses of Nocturnal Cold-Air Drainage?

    NASA Astrophysics Data System (ADS)

    Bond, B. J.; Ocheltree, T.; Pypker, T.; Unsworth, M. H.; Mix, A. C.; William, R.

    2003-12-01

    The carbon isotope signature of ecosystem respiration, δ 13CR, as measured by the Keeling Plot approach, has been related to short-term variations in weather and ecosystem function in several recent studies. In order to obtain an adequate range of [CO2] and to sample a consistent vegetation type, investigators typically select sampling locations in relatively flat terrain and uniform canopy cover, but these are unusual conditions for many forested ecosystems. In a pilot study, we are collecting samples for Keeling Plot analyses in cold-air drainage systems in small (60-100 ha), deeply-incised watersheds, one covered with old-growth (ca 450-years-old) Douglas-fir/hemlock forest and one covered with young (ca 45-years-old) Douglas-fir forest. We found that the nightly range of [CO2] was typically 380-460 ppm, sufficient to develop good estimates of δ 13CR. At any point in time there was little variation in [CO2] with height through the canopy (0.5-30m), so the required range was obtained by sampling over several hours. There was no indication that samples taken from different heights or at different times of night represented sources with different isotopic signatures. The isotopic signature of respired CO2 in the older watershed averaged about 1 per mil greater than that of the young watershed, and δ 13CR of both locations correlated with modeled stomatal conductance 6 days prior to flask sampling.

  14. Aerosols and Particulates Workshop Sampling Procedures and Venues Working Group Summary

    NASA Technical Reports Server (NTRS)

    Pachlhofer, Peter; Howard, Robert

    1999-01-01

    The Sampling Procedures and Venues Workgroup discussed the potential venues available and issues associated with obtaining measurements. Some of the issues included Incoming Air Quality, Sampling Locations, Probes and Sample Systems. The following is a summary of the discussion of the issues and venues. The influence of inlet air to the measurement of exhaust species, especially trace chemical species, must be considered. Analysis procedures for current engine exhaust emissions regulatory measurements require adjustments for air inlet humidity. As a matter of course in scientific investigations, it is recommended that "background" measurements for any species, particulate or chemical, be performed during inlet air flow before initiation of combustion, if possible, and during the engine test period as feasible and practical. For current regulatory measurements, this would be equivalent to setting the "zero" level for conventional gas analyzers. As a minimum, it is recommended that measurements of the humidity and particulates in the incoming air be taken at the start and end of each test run. Additional measurement points taken during the run are desirable if they can be practically obtained. It was felt that the presence of trace gases in the incoming air is not a significant problem. However, investigators should consider the ambient levels and influences of local air pollution for species of interest. Desired measurement locations depend upon the investigation requirements. A complete investigation of phenomenology of particulate formation and growth requires measurements at a number of locations both within the engine and in the exhaust field downstream of the nozzle exit plane. Desirable locations for both extractive and in situ measurements include: (1) Combustion Zone (Multiple axial locations); (2) Combustor Exit (Multiple radial locations for annular combustors); (3) Turbine Stage (Inlet and exit of the stage); (4) Exit Nozzle (Multiple axial locations downstream of the nozzle). Actual locations with potential for extractive or non-intrusive measurements depend upon the test article and test configuration. Committee members expressed the importance of making investigators aware of various ports that could allow access to various stages of the existing engines. Port locations are engine si)ecific and might allow extractive sampling or innovative hybrid optical-probe access. The turbine stage region was one the most desirable locations for obtaining samples and might be accessed through boroscope ports available in some engine designs. Discussions of probes and sampling systems quickly identified issues dependent on particular measurement quantities. With general consensus, the group recommends SAE procedures for measurements and data analyses of currently regulated exhaust species (CO2, CO, THC, NO(x),) using conventional gas sampling techniques. Special procedures following sound scientific practices must be developed as required for species and/or measurement conditions not covered by SAE standards. Several issues arose concerning short lived radicals and highly reactive species. For conventional sampling, there are concerns of perturbing the sample during extraction, line losses, line-wall reactions, and chemical reactions during the sample transport to the analyzers. Sample lines coated with quartz.or other materials should be investigated for minimization of such effects. The group advocates the development of innovative probe techniques and non-intrusive optical techniques for measurement of short lived radicals and highly reactive species that cannot be sampled accurately otherwise. Two innovative probe concepts were discussed. One concept uses specially designed probes to transfer optical beams to and from a region of flow inaccessible by traditional ports or windows. The probe can perturb the flow field but must have a negligible impact on the region to be optically sampled. Such probes are referred to as hybrid probes and are under development at AEDC for measurement in the high pressure, high temperature of a combustor under development for power generation. The other concept consists of coupling an instrument directly to the probe. The probe would isolate a representative sample stream, freeze chemical reactions and direct the sample into the analyzer portion of the probe. Thus, the measurement would be performed in situ without sample line losses due either to reactions or binding at the wall surfaces. This concept was used to develop a fast, in situ, time-of-flight mass spectrometer measurement system for temporal quantification of NO in the IMPULSE facility at AEDC. Additional work is required in this area to determine the best probe and sampling technique for each species measurement requirement identified by the Trace Chemistry Working Group. A partial list of Venues was used as a baseline for discussion. Additional venues were added to the list and the list was broken out into the following categories: (1)Engines (a) Sea Level Test Stands (b) Altitude Chambers; (2) Annular Combustor Test Stands, (3) Sector Flametube Test Stands, (4) Fundamentals Rigs/Experiments.

  15. Comparison of a high temperature torch integrated sample introduction system with a desolvation system for the analysis of microsamples through inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Sánchez, Raquel; Cañabate, Águeda; Bresson, Carole; Chartier, Frédéric; Isnard, Hélène; Maestre, Salvador; Nonell, Anthony; Todolí, José-Luis

    2017-03-01

    This work describes for the first time the comparison of the analytical performances obtained with a high temperature torch integrated sample introduction system (hTISIS) against those found with a commercially available desolvation system (APEX) associated with inductively coupled plasma mass spectrometry (ICP-MS). A double pass spray chamber was taken as the reference system. Similar detection limits and sensitivities were obtained in continuous injection mode at low liquid flow rates for the APEX and hTISIS operating at high temperatures. In contrast, in the air-segmented injection mode, the detection limits obtained with hTISIS at high temperatures were up to 12 times lower than those found for the APEX. Regarding memory effects, wash out times were shorter in continuous mode and peaks were narrower in air segmented mode for the hTISIS as compared to the APEX. Non spectral interferences (matrix effects) were studied with 10% nitric acid, 2% methanol, for an ICP multielemental solution and a hydro-organic matrix containing 70% (v/v) acetonitrile in water, 15 mmol L- 1 ammonium acetate and 0.5% formic acid containing lanthanide complexes. In all the cases, matrix effects were less severe for the hTISIS operating at 200 °C and the APEX than for the double pass spray chamber. Finally, two spiked reference materials (sea water and Antartic krill) were analyzed. The hTISIS operating at 200 °C gave the best results compared to those obtained with the APEX and the double pass spray chamber. In conclusion, despite the simplicity of the hTISIS, it provided, at low liquid flow rates, results similar to or better than those obtained with the by other sample introduction systems.

  16. Radiometric 81Kr dating identifies 120,000-year-old ice at Taylor Glacier, Antarctica

    PubMed Central

    Buizert, Christo; Baggenstos, Daniel; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V.; Lu, Zheng-Tian; Müller, Peter; Kuhl, Tanner; Lee, James; Severinghaus, Jeffrey P.; Brook, Edward J.

    2014-01-01

    We present successful 81Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ∼350-kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The 81Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 ± 2.5 ka. Our experimental methods and sampling strategy are validated by (i) 85Kr and 39Ar analyses that show the samples to be free of modern air contamination and (ii) air content measurements that show the ice did not experience gas loss. We estimate the error in the 81Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (Marine Isotope Stage 5e, 130–115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samples are available, greatly enhancing their scientific value as archives of old ice and meteorites. At present, ATTA 81Kr analysis requires a 40–80-kg ice sample; as sample requirements continue to decrease, 81Kr dating of ice cores is a future possibility. PMID:24753606

  17. Radiometric 81Kr dating identifies 120,000-year-old ice at Taylor Glacier, Antarctica.

    PubMed

    Buizert, Christo; Baggenstos, Daniel; Jiang, Wei; Purtschert, Roland; Petrenko, Vasilii V; Lu, Zheng-Tian; Müller, Peter; Kuhl, Tanner; Lee, James; Severinghaus, Jeffrey P; Brook, Edward J

    2014-05-13

    We present successful (81)Kr-Kr radiometric dating of ancient polar ice. Krypton was extracted from the air bubbles in four ∼350-kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The (81)Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean absolute age offset of 6 ± 2.5 ka. Our experimental methods and sampling strategy are validated by (i) (85)Kr and (39)Ar analyses that show the samples to be free of modern air contamination and (ii) air content measurements that show the ice did not experience gas loss. We estimate the error in the (81)Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (Marine Isotope Stage 5e, 130-115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samples are available, greatly enhancing their scientific value as archives of old ice and meteorites. At present, ATTA (81)Kr analysis requires a 40-80-kg ice sample; as sample requirements continue to decrease, (81)Kr dating of ice cores is a future possibility.

  18. A study of aerosol entrapment and the influence of wind speed, chamber design and foam density on polyurethane foam passive air samplers used for persistent organic pollutants.

    PubMed

    Chaemfa, Chakra; Wild, Edward; Davison, Brian; Barber, Jonathan L; Jones, Kevin C

    2009-06-01

    Polyurethane foam disks are a cheap and versatile tool for sampling persistent organic pollutants (POPs) from the air in ambient, occupational and indoor settings. This study provides important background information on the ways in which the performance of these commonly used passive air samplers may be influenced by the key environmental variables of wind speed and aerosol entrapment. Studies were performed in the field, a wind tunnel and with microscopy techniques, to investigate deployment conditions and foam density influence on gas phase sampling rates (not obtained in this study) and aerosol trapping. The study showed: wind speed inside the sampler is greater on the upper side of the sampling disk than the lower side and tethered samplers have higher wind speeds across the upper and lower surfaces of the foam disk at a wind speed > or = 4 m/s; particles are trapped on the foam surface and within the body of the foam disk; fine (<1 um) particles can form clusters of larger size inside the foam matrix. Whilst primarily designed to sample gas phase POPs, entrapment of particles ensures some 'sampling' of particle bound POPs species, such as higher molecular weight PAHs and PCDD/Fs. Further work is required to investigate how quantitative such entrapment or 'sampling' is under different ambient conditions, and with different aerosol sizes and types.

  19. On the mechanism of zirconium nitride formation by zirconium, zirconia and yttria burning in air

    NASA Astrophysics Data System (ADS)

    Malikova, Ekaterina; Pautova, Julia; Gromov, Alexander; Monogarov, Konstantin; Larionov, Kirill; Teipel, Ulrich

    2015-10-01

    The combustion of Zr and (Zr+ZrO2) powdery mixtures in air was accompanied by major ZrN stabilization. The synthesis of cheap ZrN with the high yield in air was facile and utile. The influence of Y2O3 additive on the content of ZrN the solid combustion products (SCP) was investigated. The reagents and SCP were analyzed by BET, DTA-TGA, XRD, SEM and EDS. Burning temperature was measured by thermal imager. The yield of ZrN in the SCP has been varied by the time regulation of the combustion process. The burning samples were quenched at a certain time to avoid the re-oxidation of the obtained ZrN by oxygen. The quenching of the burned (Zr+ZrO2) samples with the Y2O3 additive was allowed increasing the ZrN yield in SCP up to 66 wt%. The chemical mechanism of ZrN formation in air was discussed and the probable source of ZrN massive formation is suggested.

  20. The recent changes and topics in CONTRAIL project

    NASA Astrophysics Data System (ADS)

    Machida, Toshinobu; Umezawa, Taku; Sawa, Yousuke; Niwa, Yosuke; Matsueda, Hidekazu

    2016-04-01

    CONTRAIL (Comprehensive Observation Network for TRace gases by AIrLiner) project has been conducted since 2005 with Continuous CO2 Measuring Equipment (CME) and Automatic air Sampling Equipment (ASE) onboard commercial airliners for observations of atmospheric greenhouse gases. Japan Airlines (JAL) offers eight Boeing 777-200ER airplanes modified for CONTRAIL; CME and ASE can be installed on all and five of them, respectively. ASE measurements have provided the long records of greenhouse gases in the upper troposphere along the flight route between Japan and Australia. In addition, we started a new sampling program between Japan and Europe in 2012 to obtain data at higher latitudes and the UT/LS region. When the 777-200ER airplane was not operated for the observation route, we used Manual air Sampling Equipment (MSE) for taking air onboard as substitute for ASE. Since flight routes with 777-200ER have been restricted only to Asian countries and Hawaii in the last few years, additional two Boeing 777-300ERs were modified to install CME and expand area coverage of CO2 observations to Europe, Australia and the east coast of US in 2015-2016. We also present our recent data analysis for intensive CME observations over Delhi, India, which indicates a significant impact of Indian wintertime agriculture on the regional carbon budget.

  1. Trace gas measurements during aircraft flights in the tropopause region over Europe and North Africa

    NASA Astrophysics Data System (ADS)

    Schmidt, M.; Borchers, R.; Fabian, P.; Flentje, G.; Matthews, W. A.; Szabo, A.; Lal, S.

    During aircraft flights in May 1981 from Munich (40 deg N) to north of the Spitsbergen Islands (82 deg N) and to Monrovia, Liberia (6 deg N), air samples were obtained in the altitude range of 8 to 11 km and during the ascents and descents near the airports. These samples have been analyzed for the trace gas mixing ratios of CH4, CO and N2O. The results of these analyses are presented and discussed. The results provide new evidence of tropospheric-stratospheric exchange events in the vicinity of the subpolar and subtropical tropopause foldings and possibly show a case of transport of CO-enriched air in the upper troposphere above the North Atlantic Ocean.

  2. Estimation of indoor and outdoor ratios of selected volatile organic compounds in Canada

    NASA Astrophysics Data System (ADS)

    Xu, Jing; Szyszkowicz, Mieczyslaw; Jovic, Branka; Cakmak, Sabit; Austin, Claire C.; Zhu, Jiping

    2016-09-01

    Indoor air and outdoor air concentration (I/O) ratio can be used to identify the origins of volatile organic compounds (VOCs). I/O ratios of 25 VOCs in Canada were estimated based on the data collected in various areas in Canada between September 2009 and December 2011. The indoor VOC data were extracted from the Canadian Health Measures Survey (CHMS). Outdoor VOC data were obtained from Canada's National Air Pollution Surveillance (NAPS) Network. The sampling locations covered nine areas in six provinces in Canada. Indoor air concentrations were found higher than outdoor air for all studied VOCs, except for carbon tetrachloride. Two different approaches were employed to estimate the I/O ratios; both approaches produced similar I/O values. The I/O ratios obtained from this study were similar to two other Canadian studies where indoor air and outdoor air of individual dwellings were measured. However, the I/O ratios found in Canada were higher than those in European cities and in two large USA cities, possibly due to the fact that the outdoor air concentrations recorded in the Canadian studies were lower. Possible source origins identified for the studied VOCs based on their I/O ratios were similar to those reported by others. In general, chlorinated hydrocarbons, short-chain (C5, C6) n-alkanes and benzene had significant outdoor sources, while long-chain (C10sbnd C12) n-alkanes, terpenes, naphthalene and styrene had significant indoor sources. The remaining VOCs had mixed indoor and outdoor sources.

  3. Online air analysis of reduced sulfur compounds at a swine facility

    USDA-ARS?s Scientific Manuscript database

    Reduced sulfur compounds are emitted from waste management handling and can be important in odor production and atmospheric chemistry. Data on the emissions of these compounds have been obtained using off-line sampling and analysis methods, but on-line methods providing information on temporal chang...

  4. The Moss Techniques for Air Pollution Study in Bulgaria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marinova, S.; Marinov, A.; Frontasyeva, M.

    2010-01-21

    The paper presents new results on atmospheric deposition of 41 elements in four areas of Bulgaria during the European moss survey in 2005. The results have been obtained by the moss biomonitoring technique. Ninety seven moss samples were analyzed by instrumental neutron activation analysis (ENAA) and atomic absorption spectrometry (AAS).

  5. Diffusion sampler testing at Naval Air Station North Island, San Diego County, California, November 1999 to January 2000

    USGS Publications Warehouse

    Vroblesky, Don A.; Peters, Brian C.

    2000-01-01

    Volatile organic compound concentrations in water from diffusion samplers were compared to concentrations in water obtained by low-flow purging at 15 observation wells at the Naval Air Station North Island, San Diego, California. Multiple diffusion samplers were installed in the wells. In general, comparisons using bladder pumps and diffusion samplers showed similar volatile organic carbon concentrations. In some wells, sharp concentration gradients were observed, such as an increase in cis-1,2-dichloroethene concentration from 100 to 2,600 micrograms per liter over a vertical distance of only 3.4 feet. In areas where such sharp gradients were observed, concentrations in water obtained by low-flow sampling at times reflected an average concentration over the area of influence; however, concentrations obtained by using the diffusion sampler seemed to represent the immediate vicinity of the sampler. When peristaltic pumps were used to collect ground-water samples by low-flow purging, the volatile organic compound concentrations commonly were lower than concentrations obtained by using diffusion samplers. This difference may be due to loss of volatiles by degassing under negative pressures in the sampling lines induced while using the peristaltic pump, mixing in the well screen, or possible short-circuiting of water from an adjacent depth. Diffusion samplers placed in buckets of freephase jet fuel (JP-5) and Stoddard solvent from observation wells did not show evidence of structural integrity loss during the 2 months of equilibration, and volatile organic compounds detected in the free-phase fuel also were detected in the water from the diffusion samplers.

  6. Quantifying India's HFC emissions from whole-air samples collected on the UK-India Monsoon campaign

    NASA Astrophysics Data System (ADS)

    Say, Daniel; Ganesan, Anita; O'Doherty, Simon; Bauguitte, Stephane; Rigby, Matt; Lunt, Mark

    2017-04-01

    With a population exceeding 1 billion and a rapidly expanding economy, greenhouse gas (GHG) emissions from India are of global significance. As of 2010, India's anthropogenic GHG emissions accounted for 5.6% of the global total, with this share predicted to grow significantly in the coming decades. We focus here on hydrofluorocarbons (HFCs), a diverse range of potent GHGs, whose role as replacements for ozone-depleting CFCs and HCFCs in air-conditioning and refrigeration applications (among others) has led to rapid atmospheric accumulation. Recent efforts to reduce their consumption (and subsequent emission) culminated in an amendment to the Montreal Protocol; member states are now required to phase-down their use of HFCs, with the first cuts planned for 2019. Despite the potential climate implications, atmospheric measurements of HFCs in India, required for quantifying their emissions using top-down inverse methods, have not previously existed. Here we present the first Indian hydrofluorocarbon (HFC) observations, obtained during two months of low altitude (<2000 m) flights. Of the 176 whole air samples collected on board the UK's NERC-FAAM (Facility for Airborne Atmospheric Measurements) research aircraft, the majority were obtained above the Indo-Gangetic Plains of Northern India, where population density is greatest. Using a small subset of samples filled above the Arabian Sea, we derive compound specific baselines, to which the remaining samples are compared. Significant mole fraction enhancements are observed for all major HFCs, indicating the presence of regional emissions sources. Little enhancement is observed in the concentration of various HFC predecessors, including CFCs, suggesting India's success in phasing out the majority of ozone depleting substances. Using these atmospheric observations and the NAME (Numerical Atmospheric dispersion Modelling Environment) atmospheric transport model, we present the first regional HFC flux estimates for India.

  7. Analysis of glycols, glycol ethers, and other volatile organic compounds present in household water-based hand pump sprays.

    PubMed

    Kawakami, Tsuyoshi; Isama, Kazuo; Tanaka-Kagawa, Toshiko; Jinnno, Hideto

    2017-11-10

    The aim of this investigation is to clarify the types and concentrations of VOCs present in various commercial household water-based hand pump spray products used in Japan, and to estimate their average concentrations in indoor air when the spray product is used. We selected glycol and glycol ethers as the main target compounds, as these chemicals were detected at high frequencies and concentrations in a national survey of Japanese indoor air pollution. The extraction of these chemicals using graphite carbon cartridges was examined, with good recoveries and reproducibilities being obtained. Eighteen chemicals were analyzed in 54 commercial products and 8 chemicals were detected. More specifically, dipropylene glycol (DPG) was present in 44 samples (1.1 × 10 1 -1.8 × 10 4 μg/mL); propylene glycol (PG) was present in 22 samples (1.5 × 10 1 -2.9 × 10 4 μg/mL); diethylene glycol monoethyl ether (DGMEE) was found in 15 samples (trace amount-1.9 × 10 3 μg/mL); diethylene glycol (DEG) was present in 9 samples (1.0 × 10 1 -2.4 × 10 3 μg/mL); 1,3-butandiol (13BG) was found in 5 samples (trace amount-7.4 × 10 3 μg/mL); 2-ethyl-1-hexanol (2E1H) was detected in 5 samples (3.2 × 10 -1 -4.4 × 10 1 μg/mL); diethylene glycol monobutyl ether (DGMBE) was present in 4 samples (2.1 × 10 1 -7.1 × 10 1 μg/mL); and 3-methoxy-3-methylbutanol (MMB) was found in 2 samples (2.4 × 10 1 -4.7 × 10 2 μg/mL). In addition, the average concentrations of these chemicals in indoor air were estimated using their maximum concentrations observed in the spray product. The estimated average concentrations of the chemicals in indoor air were determined to range between 1.0 × 10 -2 and 1.0 mg/m 3 , with the exception of 2E1H and DGMBE. Furthermore, the estimated average concentrations of PG, 13BG, and DGMEE in indoor air were comparable to or higher than those reported in a national survey of Japanese indoor air pollution. It therefore appeared that household water-based hand pump sprays may contribute to the presence of these chemicals in indoor air. In contrast, estimated average concentrations of 2E1H in indoor air were low, its concentrations observed in a national survey of Japanese indoor air pollution are likely due to the use of plasticizers and paints.

  8. Self- and Air-Broadened Line Shapes in the 2v3 P and R Branches of 12CH4

    NASA Technical Reports Server (NTRS)

    Devi, V. Malathy; Benner, D. Chris; Sung, Keeyoon; Crawford, Timothy J.; Yu, Shanshan; Brown, Linda R.; Smith, Mary Ann H.; Mantz, Arlan W.; Boudon, Vincent; Ismail, Syed

    2015-01-01

    In this paper we report line shape parameters of 12CH4 for several hundred 2V(sub 3) transitions in the spectral regions 5891-5996 cm( exp -1) (P branch) and 6015-6115 cm(exp -1) (R branch). Air- and self-broadening coefficients were measured as a function of temperature; line mixing via off-diagonal relaxation matrix element coefficients was also obtained for 47 transition pairs. In total, nearly 1517 positions and intensities were retrieved, but many transitions were too weak for the line shape study. For this analysis, we used 25 high-resolution (0.0056 and 0.0067 cm(ex[ -1) and high signal-to-noise (S/N) spectra of high-purity 12CH4 and the same high-purity 12CH4 broadened by dry air recorded at different sample temperatures between 130 K and 295 K with the Bruker IFS 125HR Fourier transform spectrometer at JPL. Three different absorption cells were used (1) a White cell set to a path length of 13.09 m for room temperature data, (2) a single-pass 0.2038 m long coolable cell (for self-broadening) and (3) a multipass cell with 20.941 m total path coolable Herriott cell (for air-broadening). In total there were 13 spectra with pure 12CH4 (0.27-599 Torr) and 12 air-broadened spectra with total sample pressures of 80-805 Torr and volume mixing ratios (VMR) of methane between 0.18 and 1.0. An interactive multispectrum nonlinear least-squares technique was employed to fit the individual P10-P1 and R0-R10 manifolds in all the spectra simultaneously. Results obtained from the present analysis are compared to other recent measurements.

  9. Increased levels of ethane, a non-invasive, quantitative, direct marker of n-3 lipid peroxidation, in the breath of patients with schizophrenia.

    PubMed

    Puri, Basant K; Ross, Brian M; Treasaden, Ian H

    2008-04-01

    This study directly assessed whether there was a change in the level of exhaled ethane, which provides a non-invasive, quantitative, direct measure of n-3 lipid peroxidation, in the breath of patients with schizophrenia. Samples of alveolar air were obtained from 20 subjects with schizophrenia and 23 age- and sex-matched healthy control subjects. The air samples were analyzed for ethane using mass spectrometry. The mean level of ethane in the schizophrenia sample [5.15 (S.E. 0.56) ppb] was significantly higher than that of the healthy controls [2.63 (S.E. 0.31) ppb; p<0.0005]. A further sub-analysis showed that nicotine dependence was unlikely to be the cause of this difference. These results suggest that the measurement of exhaled ethane levels may offer a non-invasive direct biomarker of increased n-3 lipid peroxidation in schizophrenia.

  10. Observation of Superconductivity in Tetragonal FeS.

    PubMed

    Lai, Xiaofang; Zhang, Hui; Wang, Yingqi; Wang, Xin; Zhang, Xian; Lin, Jianhua; Huang, Fuqiang

    2015-08-19

    The possibility of superconductivity in tetragonal FeS has attracted considerable interest because of its similarities to the FeSe superconductor. However, all efforts made to pursue superconductivity in tetragonal FeS have failed so far, and it remains controversial whether tetragonal FeS is metallic or semiconducting. Here we report the observation of superconductivity at 5 K in tetragonal FeS that is synthesized by the hydrothermal reaction of iron powder with sulfide solution. The obtained samples are highly crystalline and less air-sensitive, in contrast to those reported in the literature, which are meta-stable and air-sensitive. Magnetic and electrical properties measurements show that the samples behave as a paramagnetic metal in the normal state and exhibit superconductivity below 5 K. The high crystallinity and the stoichiometry of the samples play important roles in the observation of superconductivity. The present results demonstrate that tetragonal FeS is a promising new platform to realize high-temperature superconductors.

  11. A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

    PubMed

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Enabling low-noise null-point scanning thermal microscopy by the optimization of scanning thermal microscope probe through a rigorous theory of quantitative measurement.

    PubMed

    Hwang, Gwangseok; Chung, Jaehun; Kwon, Ohmyoung

    2014-11-01

    The application of conventional scanning thermal microscopy (SThM) is severely limited by three major problems: (i) distortion of the measured signal due to heat transfer through the air, (ii) the unknown and variable value of the tip-sample thermal contact resistance, and (iii) perturbation of the sample temperature due to the heat flux through the tip-sample thermal contact. Recently, we proposed null-point scanning thermal microscopy (NP SThM) as a way of overcoming these problems in principle by tracking the thermal equilibrium between the end of the SThM tip and the sample surface. However, in order to obtain high spatial resolution, which is the primary motivation for SThM, NP SThM requires an extremely sensitive SThM probe that can trace the vanishingly small heat flux through the tip-sample nano-thermal contact. Herein, we derive a relation between the spatial resolution and the design parameters of a SThM probe, optimize the thermal and electrical design, and develop a batch-fabrication process. We also quantitatively demonstrate significantly improved sensitivity, lower measurement noise, and higher spatial resolution of the fabricated SThM probes. By utilizing the exceptional performance of these fabricated probes, we show that NP SThM can be used to obtain a quantitative temperature profile with nanoscale resolution independent of the changing tip-sample thermal contact resistance and without perturbation of the sample temperature or distortion due to the heat transfer through the air.

  13. Validation of selected analytical methods using accuracy profiles to assess the impact of a Tobacco Heating System on indoor air quality.

    PubMed

    Mottier, Nicolas; Tharin, Manuel; Cluse, Camille; Crudo, Jean-René; Lueso, María Gómez; Goujon-Ginglinger, Catherine G; Jaquier, Anne; Mitova, Maya I; Rouget, Emmanuel G R; Schaller, Mathieu; Solioz, Jennifer

    2016-09-01

    Studies in environmentally controlled rooms have been used over the years to assess the impact of environmental tobacco smoke on indoor air quality. As new tobacco products are developed, it is important to determine their impact on air quality when used indoors. Before such an assessment can take place it is essential that the analytical methods used to assess indoor air quality are validated and shown to be fit for their intended purpose. Consequently, for this assessment, an environmentally controlled room was built and seven analytical methods, representing eighteen analytes, were validated. The validations were carried out with smoking machines using a matrix-based approach applying the accuracy profile procedure. The performances of the methods were compared for all three matrices under investigation: background air samples, the environmental aerosol of Tobacco Heating System THS 2.2, a heat-not-burn tobacco product developed by Philip Morris International, and the environmental tobacco smoke of a cigarette. The environmental aerosol generated by the THS 2.2 device did not have any appreciable impact on the performances of the methods. The comparison between the background and THS 2.2 environmental aerosol samples generated by smoking machines showed that only five compounds were higher when THS 2.2 was used in the environmentally controlled room. Regarding environmental tobacco smoke from cigarettes, the yields of all analytes were clearly above those obtained with the other two air sample types. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  14. On the construction, comparison, and variability of airsheds for interpreting semivolatile organic compounds in passively sampled air.

    PubMed

    Westgate, John N; Wania, Frank

    2011-10-15

    Air mass origin as determined by back trajectories often aids in explaining some of the short-term variability in the atmospheric concentrations of semivolatile organic contaminants. Airsheds, constructed by amalgamating large numbers of back trajectories, capture average air mass origins over longer time periods and thus have found use in interpreting air concentrations obtained by passive air samplers. To explore some of their key characteristics, airsheds for 54 locations on Earth were constructed and compared for roundness, seasonality, and interannual variability. To avoid the so-called "pole problem" and to simplify the calculation of roundness, a "geodesic grid" was used to bin the back-trajectory end points. Departures from roundness were seen to occur at all latitudes and to correlate significantly with local slope but no strong relationship between latitude and roundness was revealed. Seasonality and interannual variability vary widely enough to imply that static models of transport are not sufficient to describe the proximity of an area to potential sources of contaminants. For interpreting an air measurement an airshed should be generated specifically for the deployment time of the sampler, especially when investigating long-term trends. Samples taken in a single season may not represent the average annual atmosphere, and samples taken in linear, as opposed to round, airsheds may not represent the average atmosphere in the area. Simple methods are proposed to ascertain the significance of an airshed or individual cell. It is recommended that when establishing potential contaminant source regions only end points with departure heights of less than ∼700 m be considered.

  15. Refinements of environmental assessment during an outbreak investigation of invasive aspergillosis in a leukemia and bone marrow transplant unit.

    PubMed

    Thio, C L; Smith, D; Merz, W G; Streifel, A J; Bova, G; Gay, L; Miller, C B; Perl, T M

    2000-01-01

    To investigate an outbreak of aspergillosis in a leukemia and bone marrow transplant (BMT) unit and to improve environmental assessment strategies to detect Aspergillus. Epidemiological investigation and detailed environmental assessment. A tertiary-care university hospital with a 37-bed leukemia and BMT unit Leukemic or BMT patients with invasive aspergillosis identified through prospective surveillance and confirmed by chart review. We verified the diagnosis of invasive fungal infection by reviewing medical charts of at-risk patients, performing a case-control study to determine risk factors for infection, instituting wet mopping to clean all floors, providing N95 masks to protect patients outside high-efficiency particulate air (HEPA)-filtered areas, altering traffic patterns into the unit, and performing molecular typing of selected Aspergillus flavus isolates. To assess the environment, we verified pressure relationships between the rooms and hallway and between buildings, and we compared the ability of large-volume (1,200 L) and small-volume (160 L) air samplers to detect Aspergillus spores. Of 29 potential invasive aspergillosis cases, 21 were confirmed by medical chart review. Risk factors for developing invasive aspergillosis included the length of time since malignancy was diagnosed (odds ratio [OR], 1.0; P=.05) and hospitalization in a patient room located near a stairwell door (OR, 3.7; P=.05). Two of five A. flavus patient isolates were identical to one of the environmental isolates. The pressure in most of the rooms was higher than in the corridors, but the pressure in the oncology unit was negative with respect to the physically adjacent hospital; consequently, the unit acted essentially as a vacuum that siphoned non-HEPA-filtered air from the main hospital. Of the 78 samples obtained with a small-volume air sampler, none grew an Aspergillus species, whereas 10 of 40 cultures obtained with a large-volume air sampler did. During active construction, Aspergillus spores may have entered the oncology unit from the physically adjacent hospital because the air pressure differed. Guidelines that establish the minimum acceptable pressures and specify which pressure relationships to test in healthcare settings are needed. Our data show that large-volume air samples are superior to small-volume samples to assess for Aspergillus in the healthcare environment.

  16. Multispectrum analysis of air-broadened spectra in the ν3 Q branch of 12CH4

    NASA Astrophysics Data System (ADS)

    Devi, V. Malathy; Benner, D. Chris; Gamache, Robert R.; Tran, H.; Smith, Mary Ann H.; Sams, Robert L.

    2018-02-01

    We report experimental measurements of spectral line shape parameters (air-broadened width, shift, and line mixing coefficients) for several transitions in the ν3 Q branch of methane in the 3000-3023 cm-1 region. 13 high-resolution, room temperature laboratory spectra of pure methane and air-broadened methane recorded with two different Fourier transform spectrometers are fitted. 12 of these spectra were acquired at 0.01 cm-1 resolution with the McMath-Pierce FTS at the National Solar Observatory on Kitt Peak, and one higher-resolution (∼0.0011 cm-1) low pressure methane spectrum was obtained with the Bruker IFS-120HR FTS at the Pacific Northwest National Laboratory, in Richland, Washington. All the spectra were obtained using high purity natural samples of CH4 and lean mixtures of the same natural CH4 in dry air. For the 12 spectra recorded at Kitt Peak, three different absorption cells (L = 5, 25 and 150 cm) were used while the methane spectrum at PNNL was obtained using a 19.95 cm long absorption cell. For the analysis, an interactive multispectrum nonlinear least squares fitting software was employed where all the 13 spectra were fitted simultaneously. An accurate and self-consistent set of line parameters were determined by constraining a few of those for severely blended transitions. Line mixing was measured for 14 transition pairs for the CH4-air collision system. A constant speed dependence parameter, consistent with measured speed dependence values obtained in other methane bands, was applied to all the transitions included in the fitted region. The present measurements are compared to values reported in the literature.

  17. Multispectrum analysis of air-broadened spectra in the ν 3 Q branch of 12CH4

    DOE PAGES

    Devi, V. Malathy; Benner, D. Chris; Gamache, Robert R.; ...

    2017-12-06

    In this paper, we report experimental measurements of spectral line shape parameters (air-broadened width, shift, and line mixing coefficients) for several transitions in the ν 3 Q branch of methane in the 3000–3023 cm -1 region. 13 high-resolution, room temperature laboratory spectra of pure methane and air-broadened methane recorded with two different Fourier transform spectrometers are fitted. 12 of these spectra were acquired at 0.01 cm -1 resolution with the McMath-Pierce FTS at the National Solar Observatory on Kitt Peak, and one higher-resolution (~0.0011 cm-1) low pressure methane spectrum was obtained with the Bruker IFS-120HR FTS at the Pacific Northwestmore » National Laboratory, in Richland, Washington. All the spectra were obtained using high purity natural samples of CH 4 and lean mixtures of the same natural CH 4 in dry air. For the 12 spectra recorded at Kitt Peak, three different absorption cells (L= 5, 25 and 150 cm) were used while the methane spectrum at PNNL was obtained using a 19.95 cm long absorption cell. For the analysis, an interactive multispectrum nonlinear least squares fitting software was employed where all the 13 spectra were fitted simultaneously. An accurate and self-consistent set of line parameters were determined by constraining a few of those for severely blended transitions. Line mixing was measured for fourteen transition pairs for the CH 4-air collision system. Lastly, a constant speed dependence parameter, consistent with measured speed dependence values obtained in other methane bands, was applied to all the transitions included in the fitted region. The present measurements are compared to values reported in the literature.« less

  18. A new study of shower age distribution in near vertical showers by EAS air shower array

    NASA Technical Reports Server (NTRS)

    Chaudhuri, N.; Basak, D. K.; Goswami, G. C.; Ghosh, B.

    1984-01-01

    The air shower array has been developed since it started operation in 1931. The array covering an area of 900 sq m now incorporates 21 particle density sampling detectors around two muon magnetic spectrographs. The air showers are detected in the size range 10 to the 4th power to 10 to the 6th power particles. A total of 11000 showers has so far been detected. Average values of shower age have been obtained in various shower size ranges to study the dependence of shower age on shower size. The core distance dependence of shower age parameter has also been analyzed for presentation.

  19. Optical molecular fluorescence determination of ultra-trace beryllium in occupational and environmental samples using highly alkaline conditions.

    PubMed

    Adams, Lori; Agrawal, Anoop; Cronin, John P; Ashley, Kevin

    2017-01-01

    Exposures to beryllium (Be), even at extremely low levels, can cause severe health effects in a percentage of those exposed; consequently, occupational exposure limits (OELs) promulgated for this element are the lowest established for any element. This work describes the advantages of using highly alkaline dye solutions for determination of Be in occupational hygiene and environmental samples by means of an optical molecular fluorescence technique after sample extraction in 1-3% (w˖w -1 ) aqueous ammonium bifluoride (NH 4 HF 2 ). Improved attributes include the ability to further enhance the detection limits of Be in extraction solutions of high acidity with minimal dilution, which is particularly beneficial when NH 4 HF 2 solutions of higher concentration are used for extraction of Be from soil samples. Significant improvements in Be method detection limits (MDLs) are obtained at levels many-fold below those reported previously for this methodology. Notably, MDLs for Be of <0.01 ng l -1 / 0.1 ng per sample have been attained, which are superior to MDLs routinely reported for this element by means of the most widely used ultra-trace elemental measurement technique, inductively coupled plasma mass spectrometry (ICP-MS). Very low MDLs for Be are essential in consideration of reductions in OELs for this element in workplace air by health organizations and regulatory agencies in the USA and internationally. Applications of enhanced Be measurements to air filter samples, surface wipe samples, soils and newly-designed occupational air sampler inserts are illustrated.

  20. Measurements of CO2 Mole Fractionand δ13C in Archived Air Samples from Cape Meares, Oregon (USA) 1977 - 1998

    NASA Astrophysics Data System (ADS)

    Clark, O.; Rice, A. L.

    2017-12-01

    Carbon dioxide (CO2) is the most abundant, anthropogenically forced greenhouse gas (GHG) in the global atmosphere. Emissions of CO2 account for approximately 75% of the world's total GHG emissions. Atmospheric concentrations of CO2 are higher now than they've been at any other time in the past 800,000 years. Currently, the global mean concentration exceeds 400 ppm. Today, global networks regularly monitor CO2 concentrations and isotopic composition (δ13C and δ18O). However, past data is sparse. Over 200 ambient air samples from Cape Meares, Oregon (45.5°N, 124.0°W), a coastal site in Western United States, were obtained by researchers at Oregon Institute of Science and Technology (OGI, now Oregon Health & Science University), between the years of 1977 and 1998 as part of a global monitoring program of six different sites in the polar, middle, and tropical latitudes of the Northern and Southern Hemispheres. Air liquefaction was used to compress approximately 1000L of air (STP) to 30bar, into 33L electropolished (SUMMA) stainless steel canisters. Select archived air samples from the original network are maintained at Portland State University (PSU) Department of Physics. These archived samples are a valuable look at changing atmospheric concentrations of CO2 and δ13C, which can contribute to a better understanding of changes in sources during this time. CO2 concentrations and δ13C of CO2 were measured at PSU, with a Picarro Cavity Ringdown Spectrometer, model G1101-i analytical system. This study presents the analytical methods used, calibration techniques, precision, and reproducibility. Measurements of select samples from the archive show rising CO2 concentrations and falling δ13C over the 1977 to 1998 period, compatible with previous observations and rising anthropogenic sources of CO2. The resulting data set was statistically analyzed in MATLAB. Results of preliminary seasonal and secular trends from the archive samples are presented.

  1. Single-layer model to predict the source/sink behavior of diffusion-controlled building materials.

    PubMed

    Kumar, Deept; Little, John C

    2003-09-01

    Building materials may act as both sources of and sinks forvolatile organic compounds (VOCs) in indoor air. A strategy to characterize the rate of absorption and desorption of VOCs by diffusion-controlled building materials is validated. A previously developed model that predicts mass transfer between a flat slab of material and the well-mixed air within a chamber or room is extended. The generalized model allows a nonuniform initial material-phase concentration and a transient influent gas-phase concentration to be simultaneously considered. An analytical solution to the more general model is developed. Experimental data are obtained by placing samples of vinyl flooring inside a small stainless steel chamber and exposing them to absorption/desorption cycles of n-dodecane and phenol. Measured values for the material-air partition coefficient and the material-phase diffusion coefficient were obtained previously in a series of completely independent experiments. The a priori model predictions are in close agreement with the observed experimental data.

  2. Influence of drying air parameters on mass transfer characteristics of apple slices

    NASA Astrophysics Data System (ADS)

    Beigi, Mohsen

    2016-10-01

    To efficiently design both new drying process and equipment and/or to improve the existing systems, accurate values of mass transfer characteristics are necessary. The present study aimed to investigate the influence of drying air parameters (i.e. temperature, velocity and relative humidity) on effective diffusivity and convective mass transfer coefficient of apple slices. The Dincer and Dost model was used to determine the mass transfer characteristics. The obtained Biot number indicated that the moisture transfer in the apple slices was controlled by both internal and external resistance. The effective diffusivity and mass transfer coefficient values obtained to be in the ranges of 7.13 × 10-11-7.66 × 10-10 and 1.46 × 10-7-3.39 × 10-7 m s-1, respectively and the both of them increased with increasing drying air temperature and velocity, and decreasing relative humidity. The validation of the model showed that the model predicted the experimental drying curves of the samples with a good accuracy.

  3. A system for high-quality CO2 isotope analyses of air samples collected by the CARIBIC Airbus A340-600.

    PubMed

    Assonov, S; Taylor, P; Brenninkmeijer, C A M

    2009-05-01

    In 2007, JRC-IRMM began a series of atmospheric CO2 isotope measurements, with the focus on understanding instrumental effects, corrections as well as metrological aspects. The calibration approach at JRC-IRMM is based on use of a plain CO2 sample (working reference CO2) as a calibration carrier and CO2-air mixtures (in high-pressure cylinders) to determine the method-related correction under actual analytical conditions (another calibration carrier, in the same form as the samples). Although this approach differs from that in other laboratories, it does give a direct link to the primary reference NBS-19-CO2. It also helps to investigate the magnitude and nature for each of the instrumental corrections and allows for the quantification of the uncertainty introduced. Critical tests were focused on the instrumental corrections. It was confirmed that the use of non-symmetrical capillary crimping (an approach used here to deal with small samples) systematically modifies delta13C(CO2) and delta18O(CO2), with a clear dependence on the amount of extracted CO2. However, the calibration of CO2-air mixtures required the use of the symmetrical dual-inlet mode. As a proof of our approach, we found that delta13C(CO2) on extracts from mixtures agreed (within 0.010 per thousand) with values obtained from the 'mother' CO2 used for the mixtures. It was further found that very low levels of hydrocarbons in the pumping systems and the isotope ratio mass spectrometry (IRMS) instrument itself were critical. The m/z 46 values (consequently the calculated delta18O(CO2) values) are affected by several other effects with traces of air co-trapped with frozen CO2 being the most critical. A careful cryo-distillation of the extracted CO2 is recommended. After extensive testing, optimisation, and routine automated use, the system was found to give precise data on air samples that can be traced with confidence to the primary standards. The typical total combined uncertainty in delta13C(CO2) and delta18O(CO2) on the VPDB-CO2 scale, estimated on runs of CO2-air mixtures, is +/-0.040 per thousand and 0.060 per thousand (2-sigma values). Inter-comparison with MPI-BGC resulted in a scale discrepancy of a similar magnitude. Although the reason(s) for this discrepancy still need to be understood, this basically confirms the approach of using specifically prepared CO2-air mixtures as a calibration carrier, in order to achieve scale unification among laboratories. As important practical application and as a critical test, JRC-IRMM took part in the passenger aircraft-based global monitoring project CARIBIC (http://www.caribic-atmospheric.com). In this way, reliable CO2 isotope data for the tropopause region and the free troposphere were obtained. From June 2007 to January 2009, approximately 500 CARIBIC air samples have been analysed. Some flights demonstrated a compact correlation of both delta13C(CO2) and delta18O(CO2) with respect to CO2 concentration, demonstrating mixing of tropospheric and stratospheric air masses. These excellent correlations provide an independent, realistic data quality check. Copyright (c) 2009 John Wiley & Sons, Ltd.

  4. Mass transfer characteristics of bisporus mushroom ( Agaricus bisporus) slices during convective hot air drying

    NASA Astrophysics Data System (ADS)

    Ghanbarian, Davoud; Baraani Dastjerdi, Mojtaba; Torki-Harchegani, Mehdi

    2016-05-01

    An accurate understanding of moisture transfer parameters, including moisture diffusivity and moisture transfer coefficient, is essential for efficient mass transfer analysis and to design new dryers or improve existing drying equipments. The main objective of the present study was to carry out an experimental and theoretical investigation of mushroom slices drying and determine the mass transfer characteristics of the samples dried under different conditions. The mushroom slices with two thicknesses of 3 and 5 mm were dried at air temperatures of 40, 50 and 60 °C and air flow rates of 1 and 1.5 m s-1. The Dincer and Dost model was used to determine the moisture transfer parameters and predict the drying curves. It was observed that the entire drying process took place in the falling drying rate period. The obtained lag factor and Biot number indicated that the moisture transfer in the samples was controlled by both internal and external resistance. The effective moisture diffusivity and the moisture transfer coefficient increased with increasing air temperature, air flow rate and samples thickness and varied in the ranges of 6.5175 × 10-10 to 1.6726 × 10-9 m2 s-1 and 2.7715 × 10-7 to 3.5512 × 10-7 m s-1, respectively. The validation of the Dincer and Dost model indicated a good capability of the model to describe the drying curves of the mushroom slices.

  5. Emissions of fluorides from welding processes.

    PubMed

    Szewczyńska, Małgorzata; Pągowska, Emilia; Pyrzyńska, Krystyna

    2015-11-01

    The levels of fluoride airborne particulates emitted from welding processes were investigated. They were sampled with the patented IOM Sampler, developed by J. H. Vincent and D. Mark at the Institute of Occupational Medicine (IOM), personal inhalable sampler for simultaneous collection of the inhalable and respirable size fractions. Ion chromatography with conductometric detection was used for quantitative analysis. The efficiency of fluoride extraction from the cellulose filter of the IOM sampler was examined using the standard sample of urban air particle matter SRM-1648a. The best results for extraction were obtained when water and the anionic surfactant N-Cetyl-N-N-N-trimethylammonium bromide (CTAB) were used in an ultrasonic bath. The limits of detection and quantification for the whole procedure were 8μg/L and 24μg/L, respectively. The linear range of calibration was 0.01-10mg/L, which corresponds to 0.0001-0.1mg of fluorides per m(3) in collection of a 20L air sample. The concentration of fluorides in the respirable fraction of collected air samples was in the range of 0.20-1.82mg/m(3), while the inhalable fraction contained 0.23-1.96mg/m(3) of fluorides during an eight-hour working day in the welding room. Copyright © 2015. Published by Elsevier B.V.

  6. Characterization of the air pollution in the urban area of Madrid

    NASA Astrophysics Data System (ADS)

    Climent-Font, Aurelio; Swietlicki, Erik; Revuelta, Antonio

    1994-03-01

    An attempt is made to characterize for the first time the urban pollution of Madrid using the combination of conventional gas measurements and an ion beam analytical technique (PIXE) for aerosol monitoring. Different sets of samples were collected selecting different seasons of the year; winter and summer 1992, and also different sampling times; 3 h and 24 h. A group of 18 elements in the mass range from Si to Pb could be analyzed. Concentration of gases in the air was recorded for the following: CO, NO x, NO 2, SO 2 and C xH y. Four sources contributing to the air pollution were obtained by means of absolute principal component analysis where automotive transport emerges as the dominating one. The combination of aerosol (PIXE) and gas data as input to a receptor model proved to be fruitful for the understanding of the underlying chemical and physical processes governing the observed pollution levels. This is a preliminary study whose results will supply the trends and strategies for a more thorough characterization.

  7. Fungal spore concentrations in indoor and outdoor air in university libraries, and their variations in response to changes in meteorological variables.

    PubMed

    Flores, María Elena Báez; Medina, Pável Gaxiola; Camacho, Sylvia Páz Díaz; de Jesús Uribe Beltrán, Magdalena; De la Cruz Otero, María del Carmen; Ramírez, Ignacio Osuna; Hernández, Martín Ernesto Tiznado

    2014-08-01

    The fungal spore concentration (FSC) in the air poses a risk for human health. This work studied the FSC in university libraries and how it is affected by environmental factors. A total of 347 samples were obtained using a Microbio MB2(®) Aerosol Sampler. The wind speed (WS), cross wind (CW), temperature (T), relative humidity (HR), barometric pressure (BP) and dew point (DP) were recorded using a Kestrel(®) 4500 weather station. The median indoor/outdoor FSC was 360/1230 CFU m(-3). FSC correlated inversely with BP, HR and DP; and positively with WS and CW; whereas T showed negative or positive correlation with FSC, depending on the region or sampling time. Eleven fungal genera were found and the dominant isolates were identified as Aspergillus niger, Aspergillus tamarii and Aspergillus oryzae. All fungi identified are known to be allergenic. It was concluded that environmental variables can influence the air FSC in different ways.

  8. Efficiencies of Tritium (3H) bubbling systems.

    PubMed

    Duda, Jean-Marie; Le Goff, Pierre; Leblois, Yoan; Ponsard, Samuel

    2018-09-01

    Bubbling systems are among the devices most used by nuclear operators to measure atmospheric tritium activity in their facilities or the neighbouring environment. However, information about trapping efficiency and bubbling system oxidation is not accessible and/or, at best, only minimally supported by demonstrations in actual operating conditions. In order to evaluate easily these parameters and thereby meet actual normative and regulatory requirements, a statistical study was carried out over 2000 monitoring records from the CEA Valduc site. From this data collection obtained over recent years of monitoring the CEA Valduc facilities and environment, a direct relation was highlighted between the 3H-samplers trapping efficiency of tritium as tritiated water and the sampling time and conditions of use: temperature and atmospheric moisture. It was thus demonstrated that this efficiency originated from two sources. The first one is intrinsic to the bubbling system operating parameters and the sampling time. That part applies equally to all four bubblers. The second part, however, is specific to the first bubbler. In essence, it depends on the sampling time and the sampled air characteristics. It was also highlighted that the water volume variation in the first bubbler, between the beginning and the end of the sampling process, is directly related to the average water concentration of the sampled air. In this way, it was possible to model the variations in trapping efficiency of the 3H-samplers relative to the sampling time and the water volume variation in the first bubbler. This model makes it possible to obtain the quantities required to comply with the current standards governing the monitoring of radionuclides in the environment and to associate an uncertainty concerning the measurements as well as the sampling parameters. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Study of the antioxidant properties of extracts obtained from nopal cactus (Opuntia ficus-indica) cladodes after convective drying.

    PubMed

    Medina-Torres, Luis; Vernon-Carter, E Jaime; Gallegos-Infante, J Alberto; Rocha-Guzman, Nuria E; Herrera-Valencia, E E; Calderas, Fausto; Jiménez-Alvarado, Rubén

    2011-04-01

    The process of convective drying was evaluated in terms of the bioactive compounds contained in nopal samples before and after dehydration. Total polyphenol, flavonoid, flavonol, carotene and ascorbic acid contents were determined in undehydrated and dehydrated samples. Two drying temperatures (45 and 65 °C) and two air flow rates (3 and 5 m s(-1) ) were evaluated. The rheology of samples under the best drying conditions was also studied, since it provides important information regarding processing (mixing, flow processing) as well as the sensory attributes (texture) of rehydrated samples. Non-Newtonian shear-thinning behaviour was observed for samples dried at 45 °C, while samples dried at 65 °C showed shear-thickening behaviour, possibly caused by thermal chain scission of high-molecular-weight components. The best conditions for bioactive compound preservation were a drying temperature of 45 °C and an air flow rate of 3 m s(-1) , resulting in 40.97 g phenols, 23.41 g flavonoids, 0.543 g β-carotene and 0.2815 g ascorbic acid kg(-1) sample as shown in table 3. Copyright © 2011 Society of Chemical Industry.

  10. Study of the ambient air metallic elements Cr, Cu, Zn, Cd and Pb at HAF sampling sites.

    PubMed

    Fang, Guor-Cheng; Kuo, Yu-Chen; Zhuang, Yuan-Jie; Tsai, Kai-Hsiang; Huang, Wen-Chuan

    2017-08-01

    This study characterized diurnal variations in the compositions of total suspended particulates (TSP) and dry deposits of particulates from ambient air, and the metallic elements that are contained in them at harbor, airport and farmland (HAF) sampling sites from August, 2013 to July, 2014. Two-way ANOVA of the amounts of metallic elements in the TSP and dry deposits was carried out in all four seasons at the HAF sampling sites. The metallic elements Cr and Cu originated in local emission sources at the airport. Metallic elements Zn and Pb originated in local emission sources at the harbor. Finally, metallic element Cd originated in local emissions form farmland. The following results were also obtained. (1) The metallic composition of the TSP differed significantly from that of the dry deposits in all four seasons at the harbor and farmland sampling sites, but not at the airport sampling site. (2) High correlations coefficients were found between the amounts of metallic elements Cr and Cu in the TSP and those in the dry deposits at the airport sampling site. (3) Pb was present in the TSP and the dry deposits at the harbor sampling site.

  11. Flammability Aspects of a Cotton-Fiberglass Fabric in Opposed and Concurrent Airflow in Microgravity

    NASA Technical Reports Server (NTRS)

    Ferkul, Paul V.; Olson, Sandra; Johnston, Michael C.; T'ien, James

    2012-01-01

    Microgravity combustion tests burning fabric samples were performed aboard the International Space Station. The cotton-fiberglass blend samples were mounted inside a small wind tunnel which could impose air flow speeds up to 40 cm/s. The wind tunnel was installed in the Microgravity Science Glovebox which supplied power, imaging, and a level of containment. The effects of air flow speed on flame appearance, flame growth, and spread rates were determined in both the opposed and concurrent flow configuration. For the opposed flow configuration, the flame quickly reached steady spread for each flow speed, and the spread rate was fastest at an intermediate value of flow speed. These tests show the enhanced flammability in microgravity for this geometry, since, in normal gravity air, a flame self-extinguishes in the opposed flow geometry (downward flame spread). In the concurrent flow configuration, flame size grew with time during the tests. A limiting length and steady spread rate were obtained only in low flow speeds ( 10 cm/s) for the short-length samples that fit in the small wind tunnel. For these conditions, flame spread rate increased linearly with increasing flow. This is the first time that detailed transient flame growth data was obtained in purely forced flows in microgravity. In addition, by decreasing flow speed to a very low value (around 1 cm/s), quenching extinction was observed. The valuable results from these long-duration experiments validate a number of theoretical predictions and also provide the data for a transient flame growth model under development.

  12. Elemental concentrations in tropospheric and lower stratospheric air in a Northeastern region of Poland

    NASA Astrophysics Data System (ADS)

    Braziewicz, Janusz; Kownacka, Ludwika; Majewska, Urszula; Korman, Andrzej

    Element concentrations of K, Ca, Ti, Cr, Fe, Ni, Cu, Zn, Se, Br, Sr and Pb as well as the activity of natural radionuclides 210Pb and 226Ra in air were measured. The aerosol samples were collected during tropospheric and stratospheric aircraft flights over the Northeastern region of Poland, which is mostly an agricultural and wooded area. The air volumes were filtered using Petrianov filters at 1, 3, 6, 9, 12 and 15 km above the ground level by special equipment attached to a jet plane. Aircraft flights were provided from September 1997 to August 1998 in 5 separate sampling runs. The long sampling distances served as a good representation of mean aerosol composition and distribution. Concentrations of the same elements were also measured using stationary equipment near the ground level at the outskirts of Warsaw. The vertical profiles of element concentration were obtained and the elemental compositions for the tropospheric and stratospheric aerosols were compared with those from the near-ground level. Contribution of K, Ca, Ti and Fe, which are the main components of soil, in total mass of all detected ones was estimated. Relative concentrations of all measured elements, which show any differences in the composition of the aerosol were calculated. The results obtained confirm the fact that the stratospheric reservoir is observed in the bottom stratosphere. The XRF method based on molybdenum X-ray tube was used as an analytical tool in the determination of aerosols trace elements. The altitude distributions of radioactivity of 226Ra and 210Pb were determined using radiochemical methods.

  13. A novel personal air sampling device for collecting volatile organic compounds: a comparison to charcoal tubes and diffusive badges.

    PubMed

    Rossner, Alan; Farant, Jean-Pierre

    2004-02-01

    Evacuated canisters have been used for many years to collect ambient air samples for gases and vapors. Recently, significant interest has arisen in using evacuated canisters for personal breathing zone sampling as an alternative to sorbent sampling. A novel flow control device was designed and built at McGill University. The flow control device was designed to provide a very low flow rate, <0.5 mL/min, to allow a sample to be collected over an extended period of time. Previous experiments run at McGill have shown agreement between the mathematical and empirical models to predict flow rate. The flow control device combined with an evacuated canister (capillary flow control-canister) was used in a series of experiments to evaluate its performance against charcoal tubes and diffusive badges. Air samples of six volatile organic compounds were simultaneously collected in a chamber using the capillary flow control-canister, charcoal tubes, and diffusive badges. Five different concentrations of the six volatile organic compounds were evaluated. The results from the three sampling devices were compared to each other and to concentration values obtained using an online gas chromatograph (GC). Eighty-four samples of each method were collected for each of the six chemicals. Results indicate that the capillary flow control-canister device compares quite favorably to the online GC and to the charcoal tubes, p > 0.05 for most of the tests. The capillary flow control-canister was found to be more accurate for the compounds evaluated, easier to use, and easier to analyze than charcoal tubes and passive dosimeter badges.

  14. Evaluation of passive diffusion bag and dialysis samplers in selected wells at Hickam Air Force Base, Hawaii, July 2001

    USGS Publications Warehouse

    Vroblesky, Don A.; Pravecek, Tasha

    2002-01-01

    Field comparisons of chemical concentrations obtained from dialysis samplers, passive diffusion bag samplers, and low-flow samplers showed generally close agreement in most of the 13 wells tested during July 2001 at Hickam Air Force Base, Hawaii. The data for chloride, sulfate, iron, alkalinity, arsenic, and methane appear to show that the dialysis samplers are capable of accurately collecting a passive sample for these constituents. In general, the comparisons of volatile organic compound concentrations showed a relatively close correspondence between the two different types of diffusion samples and between the diffusion samples and the low-flow samples collected in most wells. Divergence appears to have resulted primarily from the pumping method, either producing a mixed sample or water not characteristic of aquifer water moving through the borehole under ambient conditions. The fact that alkalinity was not detected in the passive diffusion bag samplers, highly alkaline waters without volatilization loss from effervescence, which can occur when a sample is acidified for preservation. Both dialysis and passive diffusion bag samplers are relatively inexpensive and can be deployed rapidly and easily. Passive diffusion bag samplers are intended for sampling volatile organic compounds only, but dialysis samplers can be used to sample both volatile organic compounds and inorganic solutes. Regenerated cellulose dialysis samplers, however, are subject to biodegradation and probably should be deployed no sooner than 2 weeks prior to recovery. 1 U.S. Geological Survey, Columbia, South Carolina. 2 Air Florce Center for Environmental Excellence, San Antionio, Texas.

  15. Plastic Foam Porosity Characterization by Air-Borne Ultrasound

    NASA Astrophysics Data System (ADS)

    Hoffrén, H.; Karppinen, T.; Hæggström, E.

    2006-03-01

    We continue to develop an ultrasonic burst-reflection method for estimating porosity and tortuosity of solid materials. As a first step we report on method design considerations and measurements on polyurethane foams (Sylomer® vibration dampener) with well-defined porosity. The ultrasonic method is experimentally tested by measuring 235 kHz and 600 kHz air-borne ultrasound reflection from a foam surface at two incidence angles. The reflected sound wave from different foam samples (32% - 64% porosity) was compared to a wave that had traveled from the transmitter to the detector without reflection. The ultrasonically estimated sample porosities coincided within 8% with the porosity estimates obtained by a gravimetric reference method. This parallels the uncertainty of the gravimetric method, 8%. The repeatability of the ultrasonic porosity measurements was better than 5%.

  16. Development of remote sensing techniques capable of delineating soils as an aid to soil survey

    NASA Technical Reports Server (NTRS)

    Coleman, T. L.; Montgomery, O. L.

    1988-01-01

    Eighty-one benchmark soils from Alabama, Georgia, Florida, Tennessee, and Mississippi were evaluated to determine the feasibility of spectrally differentiating among soil categories. Relationships among spectral properties that occur between soils and within soils were examined, using discriminant analysis. Soil spectral data were obtained from air-dried samples using an Exotech Model 20C field spectroradiometer (0.37 to 2.36 microns). Differentiating among the orders, suborders, great groups, and subgroups using reflectance spectra achieved varying percentages of accuracy. Six distinct reflectance curve forms were developed from the air-dried samples based on the shape and presence or absence of adsorption bands. Iron oxide and organic matter content were the dominant soil parameters affecting the spectral characteristics for differentiating among and between these soils.

  17. Development of a High-Resolution Laser Absorption Spectroscopy Method with Application to the Determination of Absolute Concentration of Gaseous Elemental Mercury in Air.

    PubMed

    Srivastava, Abneesh; Hodges, Joseph T

    2018-06-05

    Isotope dilution-cold-vapor-inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has become the primary standard for measurement of gaseous elemental mercury (GEM) mass concentration. However, quantitative mass spectrometry is challenging for several reasons including (1) the need for isotopic spiking with a standard reference material, (2) the requirement for bias-free passive sampling protocols, (3) the need for stable mass spectrometry interface design, and (4) the time and cost involved for gas sampling, sample processing, and instrument calibration. Here, we introduce a high-resolution laser absorption spectroscopy method that eliminates the need for sample-specific calibration standards or detailed analysis of sample treatment losses. This technique involves a tunable, single-frequency laser absorption spectrometer that measures isotopically resolved spectra of elemental mercury (Hg) spectra of 6 1 S 0 ← 6 3 P 1 intercombination transition near λ = 253.7 nm. Measured spectra are accurately modeled from first-principles using the Beer-Lambert law and Voigt line profiles combined with literature values for line positions, line shape parameters, and the spontaneous emission Einstein coefficient to obtain GEM mass concentration values. We present application of this method for the measurement of the equilibrium concentration of mercury vapor near room temperature. Three closed systems are considered: two-phase mixtures of liquid Hg and its vapor and binary two-phase mixtures of Hg-air and Hg-N 2 near atmospheric pressure. Within the experimental relative standard uncertainty, 0.9-1.5% congruent values of the equilibrium Hg vapor concentration are obtained for the Hg-only, Hg-air, Hg-N 2 systems, in confirmation with thermodynamic predictions. We also discuss detection limits and the potential of the present technique to serve as an absolute primary standard for measurements of gas-phase mercury concentration and isotopic composition.

  18. The field campaigns of the European Tracer Experiment (ETEX). overview and results

    NASA Astrophysics Data System (ADS)

    Nodop, K.; Connolly, R.; Girardi, F.

    As part of the European Tracer Experiment (ETEX) two successful atmospheric experiments were carried out in October and November, 1994. Perfluorocarbon (PFC) tracers were released into the atmosphere in Monterfil, Brittany, and air samples were taken at 168 stations in 17 European countries for 72 h after the release. Upper air tracer measurements were made from three aircraft. During the first experiment a westerly air flow transported the tracer plume north-eastwards across Europe. During the second release the flow was eastwards. The results from the ground sampling network allowed the determination of the cloud evolution as far as Sweden, Poland and Bulgaria. This demonstrated that the PFT technique can be successfully applied in long-range tracer experiments up to 2000 km. Typical background concentrations of the tracer used are around 5-7 fl ℓ -1 in ambient air. Concentrations in the plume ranged from 10 to above 200 fl/ℓ -1. The tracer release characteristics, the tracer concentrations at the ground and in upper air, the routine and additional meteorological observations at the ground level and in upper air, trajectories derived from constant-level balloons and the meteorological input fields for long-range transport models are assembled in the ETEX database. The ETEX database is accessible via the Internet. Here, an overview is given of the design of the experiment, the methods used and the data obtained.

  19. Online monitoring of water-soluble ionic composition of PM10 during early summer over Lanzhou City.

    PubMed

    Fan, Jin; Yue, Xiaoying; Jing, Yi; Chen, Qiang; Wang, Shigong

    2014-02-01

    Lanzhou is one of the most aerosol-polluted cities in China. In this study, an online analyzer for Monitoring for AeRosols and GAses was deployed to measure major water-soluble inorganic ions in PM10 at 1-hour time resolution, and 923 samples were obtained from Apr 1 to May 24, 2011. During the field campaign, air pollution days were encountered with Air Quality Index more than 100 and daily average concentration of PM10 exceeding 150 microg/m3. Based on the variation of water-soluble ions and results of Positive Matrix Factorization 3.0 model execution, the air pollution days were classified as crustal species- or secondary aerosol-induced, and the different formation mechanisms of these two air pollution types were studied. During the crustal species pollution days, the content of Ca2+ increased and was about 2.3 times higher than the average on clear days, and the air parcel back trajectory was used to analyze the sources of crustal species. Data on sulfate, trace gases and meteorological factors were used to reveal the formation mechanism of secondary aerosol pollution. The sulfur oxidation ratio (SOR) was derived from the 923 samples, and the SOR had high positive correlation with relative humidity in early summer in Lanzhou.

  20. Classification of buildings mold threat using electronic nose

    NASA Astrophysics Data System (ADS)

    Łagód, Grzegorz; Suchorab, Zbigniew; Guz, Łukasz; Sobczuk, Henryk

    2017-07-01

    Mold is considered to be one of the most important features of Sick Building Syndrome and is an important problem in current building industry. In many cases it is caused by the rising moisture of building envelopes surface and exaggerated humidity of indoor air. Concerning historical buildings it is mostly caused by outdated raising techniques among that is absence of horizontal isolation against moisture and hygroscopic materials applied for construction. Recent buildings also suffer problem of mold risk which is caused in many cases by hermetization leading to improper performance of gravitational ventilation systems that make suitable conditions for mold development. Basing on our research there is proposed a method of buildings mold threat classification using electronic nose, based on a gas sensors array which consists of MOS sensors (metal oxide semiconductor). Used device is frequently applied for air quality assessment in environmental engineering branches. Presented results show the interpretation of e-nose readouts of indoor air sampled in rooms threatened with mold development in comparison with clean reference rooms and synthetic air. Obtained multivariate data were processed, visualized and classified using a PCA (Principal Component Analysis) and ANN (Artificial Neural Network) methods. Described investigation confirmed that electronic nose - gas sensors array supported with data processing enables to classify air samples taken from different rooms affected with mold.

  1. Design of a portable gas chromatography with a conducting polymer nanocomposite detector device and a method to analyze a gas mixture.

    PubMed

    Pirsa, Sajad

    2017-04-01

    A portable chromatography device and a method were developed to analyze a gas mixture. The device comprises a chromatographic column for separating components of a sample of the gas mixture. It has an air pump coupled to the inlet of a chromatographic column for pumping air and an injector coupled to the inlet of chromatographic column for feeding the sample using the air as a carrier gas. A detector is arranged downstream from and coupled to the outlet of the chromatographic column. The detector is a nanostructure semiconductive microfiber. The device further comprises an evaluation unit arranged and configured to evaluate each detected component to determine the concentration. The designed portable system was used for simultaneous detection of amines. The possibility of applying dispersive liquid-liquid microextraction for the determination of analytes in trace levels is demonstrated. The reproducibility of this method is acceptable, and good standard deviations were obtained. The relative standard deviation value is less than 6% for all analytes. Finally, the method was successfully applied to the extraction and determination of analytes in water samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Bacteriological evaluation of a down-draught necropsy table ventilation system.

    PubMed Central

    al-Wali, W; Kibbler, C C; McLaughlin, J E

    1993-01-01

    AIMS--To evaluate the microbiological efficacy of a down-draught necropsy table ventilation system (which surrounds the cadaver with a "curtain" of air under continuous extraction) during post mortem procedures. METHODS--Air sampling was carried out both in the presence and absence of staff and cadaver and during a full post mortem procedure, with functioning and non-functioning table air extraction. The penetration of the air "curtain" was also examined during the use of an oscillating bone saw by means of a tracer organism, Bacillus subtilis var niger, painted on to the skull. RESULTS--There was little difference between bacterial counts obtained in the presence of staff only, staff plus cadaver, or during a post mortem examination. With all counts obtained, however, there was a two to three-fold reduction when the ventilation was in operation compared with when the extract duct was occluded. Using the tracer organism, a two to three log reduction in counts was shown when the "curtain" was in operation during the use of the oscillating bone saw. CONCLUSIONS--These results suggest that the system provides potential protection for post mortem room staff against airborne infections. PMID:8408701

  3. Diagnostics of femoral head status in humans using laser spectroscopy - In vitro studies.

    PubMed

    Lin, Huiying; Li, Wansha; Zhang, Hao; Chen, Peng; Chen, Delong; He, Wei; Svanberg, Sune; Svanberg, Katarina

    2017-10-01

    Osteonecrosis of the femoral head (ONFH), a recalcitrant and disabling disease, is caused by inadequate or fully disrupted blood supply to the affected segment of the subchondral bone. Theoretically, there will develop gas-filled pores during the bone decay process due to lacking blood supply. Unfortunately, the relationship between the gas-filled pores and ONFH is still unclear. Here, we have introduced diode laser absorption spectroscopy to detect oxygen and water vapor signals in the femoral heads from hip replacement in 19 patients. Five samples are affected by osteoarthritis (OA) and the others are related to ONFH. Oxygen and water vapor signals could be obtained, demonstrating the presence of gas-filled pores in both the OA and ONFH groups while the measurement results showed no significant difference. A study of gas exchange was also performed on one excised bone sample to study how these gas pores communicate with the ambient air. The results suggested that the obtained oxygen signals inside the bone samples originate from the invasion of ambient air, which is not expected in vivo. In conclusion, the ability to detect the gas signal of laser absorption spectroscopy shows the potential for the medical application of assessing the human femoral head in vivo. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Sampling Odor Substances by Mist-Cyclone System

    NASA Astrophysics Data System (ADS)

    Matsubara, Osamu; Jiang, Zhiheng; Toyama, Shigeki

    2009-05-01

    Many techniques have been developed to measure odor substances. However most of those methods are based on using aquatic solutions(1),(2). Many odor substances specifically at low density situation, are difficult to dissolve into water. To absorb odor substances and obtain highest concentration solutions are key problems for olfactory systems. By blowing odor substances contained air mixture through mist of water and then separating the liquid from two-phases fluid with a cyclone unit a high concentration solution was obtained.

  5. Particle penetration into the automotive interior. I. Influence of vehicle speed and ventilatory mode.

    PubMed

    Muilenberg, M L; Skellenger, W S; Burge, H A; Solomon, W R

    1991-02-01

    Penetration of particulate aeroallergens into the interiors of two, new, similar Chrysler Corporation passenger vehicles (having no evidence of intrinsic microbial contamination) was studied on a large circular test track during periods of high pollen and spore prevalence. Impactor collections were obtained at front and rear seat points and at the track center during periods with (1) windows and vents closed and air conditioning on, (2) windows closed, vents open, and no air conditioning, and (3) air conditioner off, front windows open, and vents closed. These conditions were examined sequentially during travel at 40, 50, 60, and 80 kph. Particle recoveries within the two, new, similar Chrysler Corporation passenger vehicles did not vary with the speed of travel, either overall or with regard to each of the three ventilatory modalities. In addition, collections at front and rear seat sampling points were comparable. Highest interior aeroallergen levels were recorded with WO, and yet, these levels averaged only half the concurrent outside concentrations at track center. Recoveries within the cars were well below recoveries obtained outside when windows were closed (both VO and AC modes). These findings suggest window ventilation as an overriding factor determining particle ingress into moving vehicles. Efforts to delineate additional determinants of exposure by direct sampling are feasible and would appear essential in formulating realistic strategies of avoidance.

  6. Self- and Air-Broadened Line Shape Parameters of (12)CH(4) : 4500-4620 cm(-1)

    NASA Astrophysics Data System (ADS)

    Devi, V. Malathy; Benner, D. Chris; Sung, K.; Brown, L. R.; Crawford, T. J.; Smith, M. A. H.; Mantz, A. W.; Predoi-Cross, A.

    2014-06-01

    Accurate knowledge of spectral line shape parameters is important for infrared transmission and radiance calculations in the terrestrial atmosphere. We report the self and air-broadened Lorentz widths, shifts and line mixing coefficients along with their temperature dependencies for methane absorption lines in the 2.2 µm spectral region. For this, we obtained a series of high-resolution, high S/N spectra of 99.99% 12C-enriched samples of pure methane and its dilute mixtures in dry air at cold temperatures down to 150 K using the Bruker IFS 125HR Fourier transform spectrometer at JPL. The coolable absorption cell had an optical path of 20.38 cm and was specially built to reside inside the sample compartment of the Bruker FTS1. The 13 spectra used in the analysis consisted of seven pure 12CH4 spectra at pressures from 4.5 to 169 Torr and six air-broadened spectra with total sample pressures of 113-300 Torr and methane volume mixing ratios between 4 and 9.7%. These 13 spectra were fit simultaneously using the multispectrum least-squares fitting technique2. The results will be compared to existing values reported in the literature3. as part of the GNU EPrints system , and is freely redistributable under the GPL .

  7. Electricity generation in single-chamber microbial fuel cells using a carbon source sampled from anaerobic reactors utilizing grass silage.

    PubMed

    Catal, Tunc; Cysneiros, Denise; O'Flaherty, Vincent; Leech, Dónal

    2011-01-01

    Production of electricity from samples obtained during anaerobic digestion of grass silage was examined using single-chamber air-cathode mediator-less microbial fuel cells (MFCs). The samples were obtained from anaerobic reactors at start-up conditions after 3 and 10 days of operation under psychrophilic (15 °C) and mesophilic (37 °C) temperatures. Electricity was directly produced from all samples at a concentration of 1500 mg CODL(-1). Power density obtained from the samples, as a sole carbon source, ranged from 56 ± 3 Wm(-3) to 31 ± 1 Wm(-3) for the mesophilic and psychrophilic samples, respectively. Coulombic efficiencies ranged from 18 ± 1% to 12 ± 1% for the same samples. The relationship between the maximum voltage output and initial COD concentration appeared to follow saturation kinetics at the external resistance of 217 Ω. Chemical oxygen demand (COD) removal was over 90% and total phenolics removal was in the range of 30-75% for all samples tested, with a standard amount of 60 mg L(-1) total phenolics removed for every sample. Our results indicate that generating electricity from solution samples of anaerobic reactors utilizing grass silage is possible, opening the possibility for combination of anaerobic digestion with MFC technology for energy generation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. Incident-response monitoring technologies for aircraft cabin air quality

    NASA Astrophysics Data System (ADS)

    Magoha, Paul W.

    Poor air quality in commercial aircraft cabins can be caused by volatile organophosphorus (OP) compounds emitted from the jet engine bleed air system during smoke/fume incidents. Tri-cresyl phosphate (TCP), a common anti-wear additive in turbine engine oils, is an important component in today's global aircraft operations. However, exposure to TCP increases risks of certain adverse health effects. This research analyzed used aircraft cabin air filters for jet engine oil contaminants and designed a jet engine bleed air simulator (BAS) to replicate smoke/fume incidents caused by pyrolysis of jet engine oil. Field emission scanning electron microscopy (FESEM) with X-ray energy dispersive spectroscopy (EDS) and neutron activation analysis (NAA) were used for elemental analysis of filters, and gas chromatography interfaced with mass spectrometry (GC/MS) was used to analyze used filters to determine TCP isomers. The filter analysis study involved 110 used and 90 incident filters. Clean air filter samples exposed to different bleed air conditions simulating cabin air contamination incidents were also analyzed by FESEM/EDS, NAA, and GC/MS. Experiments were conducted on a BAS at various bleed air conditions typical of an operating jet engine so that the effects of temperature and pressure variations on jet engine oil aerosol formation could be determined. The GC/MS analysis of both used and incident filters characterized tri- m-cresyl phosphate (TmCP) and tri-p-cresyl phosphate (TpCP) by a base peak of an m/z = 368, with corresponding retention times of 21.9 and 23.4 minutes. The hydrocarbons in jet oil were characterized in the filters by a base peak pattern of an m/z = 85, 113. Using retention times and hydrocarbon thermal conductivity peak (TCP) pattern obtained from jet engine oil standards, five out of 110 used filters tested had oil markers. Meanwhile 22 out of 77 incident filters tested positive for oil fingerprints. Probit analysis of jet engine oil aerosols obtained from BAS tests by optical particle counter (OPC) revealed lognormal distributions with the mean (range) of geometric mass mean diameter (GMMD) = 0.41 (0.39, 0.45) microm and geometric standard deviation (GSD), sigma g = 1.92 (1.87, 1.98). FESEM/EDS and NAA techniques found a wide range of elements on filters, and further investigations of used filters are recommended using these techniques. The protocols for air and filter sampling and GC/MS analysis used in this study will increase the options available for detecting jet engine oil on cabin air filters. Such criteria could support policy development for compliance with cabin air quality standards during incidents.

  9. Effect of heating-ventilation-air conditioning system sanitation on airborne fungal populations in residential environments.

    PubMed

    Garrison, R A; Robertson, L D; Koehn, R D; Wynn, S R

    1993-12-01

    Commercial air duct sanitation services are advertised to the public as being effective in reducing indoor aeroallergen levels despite the absence of published supporting data. Eight residential heat-ventilation-air conditioning (HVAC) systems in six homes and seven HVAC systems in five homes in winter and summer, respectively, were sampled to determine fungal colony forming units (CFUs) prior to and after an HVAC sanitation procedure was performed by a local company. Two houses in which no sanitation procedure was performed served as controls in each study phase. Two sample sets were obtained at each HVAC system prior to cleaning in order to determine baseline CFU levels. The test HVAC systems were then cleaned, and the HVAC systems allowed to operate as desired by the residents. Posttreatment sampling was performed 48 hours and then weekly after cleaning for 8 weeks. The HVAC systems were analyzed by exposing sterile 2% malt extract media plates at a 90-degree angle to the air flow at the air supply and air return vents. The baseline CFUs were similar in the control and study houses. Eight weeks after sanitation, the study houses demonstrated an overall CFU reduction of 92% during winter and 84% during summer. No reduction in CFU values was observed over the 8-week study period for the houses selected as controls. Further, HVAC sanitation appeared to reduce the number of fungal colonies entering and leaving the HVAC system, suggesting that the HVAC contained a significant percentage of the total fungal load in these homes. These data suggest that HVAC sanitation may be an effective tool in reducing airborne fungal populations in residential environments.

  10. Validation of the Hirst-Type Spore Trap for Simultaneous Monitoring of Prokaryotic and Eukaryotic Biodiversities in Urban Air Samples by Next-Generation Sequencing.

    PubMed

    Núñez, Andrés; Amo de Paz, Guillermo; Ferencova, Zuzana; Rastrojo, Alberto; Guantes, Raúl; García, Ana M; Alcamí, Antonio; Gutiérrez-Bustillo, A Montserrat; Moreno, Diego A

    2017-07-01

    Pollen, fungi, and bacteria are the main microscopic biological entities present in outdoor air, causing allergy symptoms and disease transmission and having a significant role in atmosphere dynamics. Despite their relevance, a method for monitoring simultaneously these biological particles in metropolitan environments has not yet been developed. Here, we assessed the use of the Hirst-type spore trap to characterize the global airborne biota by high-throughput DNA sequencing, selecting regions of the 16S rRNA gene and internal transcribed spacer for the taxonomic assignment. We showed that aerobiological communities are well represented by this approach. The operational taxonomic units (OTUs) of two traps working synchronically compiled >87% of the total relative abundance for bacterial diversity collected in each sampler, >89% for fungi, and >97% for pollen. We found a good correspondence between traditional characterization by microscopy and genetic identification, obtaining more-accurate taxonomic assignments and detecting a greater diversity using the latter. We also demonstrated that DNA sequencing accurately detects differences in biodiversity between samples. We concluded that high-throughput DNA sequencing applied to aerobiological samples obtained with Hirst spore traps provides reliable results and can be easily implemented for monitoring prokaryotic and eukaryotic entities present in the air of urban areas. IMPORTANCE Detection, monitoring, and characterization of the wide diversity of biological entities present in the air are difficult tasks that require time and expertise in different disciplines. We have evaluated the use of the Hirst spore trap (an instrument broadly employed in aerobiological studies) to detect and identify these organisms by DNA-based analyses. Our results showed a consistent collection of DNA and a good concordance with traditional methods for identification, suggesting that these devices can be used as a tool for continuous monitoring of the airborne biodiversity, improving taxonomic resolution and characterization together. They are also suitable for acquiring novel DNA amplicon-based information in order to gain a better understanding of the biological particles present in a scarcely known environment such as the air. Copyright © 2017 American Society for Microbiology.

  11. Validation of the Hirst-Type Spore Trap for Simultaneous Monitoring of Prokaryotic and Eukaryotic Biodiversities in Urban Air Samples by Next-Generation Sequencing

    PubMed Central

    Núñez, Andrés; Amo de Paz, Guillermo; Ferencova, Zuzana; Rastrojo, Alberto; Guantes, Raúl; García, Ana M.; Alcamí, Antonio; Gutiérrez-Bustillo, A. Montserrat

    2017-01-01

    ABSTRACT Pollen, fungi, and bacteria are the main microscopic biological entities present in outdoor air, causing allergy symptoms and disease transmission and having a significant role in atmosphere dynamics. Despite their relevance, a method for monitoring simultaneously these biological particles in metropolitan environments has not yet been developed. Here, we assessed the use of the Hirst-type spore trap to characterize the global airborne biota by high-throughput DNA sequencing, selecting regions of the 16S rRNA gene and internal transcribed spacer for the taxonomic assignment. We showed that aerobiological communities are well represented by this approach. The operational taxonomic units (OTUs) of two traps working synchronically compiled >87% of the total relative abundance for bacterial diversity collected in each sampler, >89% for fungi, and >97% for pollen. We found a good correspondence between traditional characterization by microscopy and genetic identification, obtaining more-accurate taxonomic assignments and detecting a greater diversity using the latter. We also demonstrated that DNA sequencing accurately detects differences in biodiversity between samples. We concluded that high-throughput DNA sequencing applied to aerobiological samples obtained with Hirst spore traps provides reliable results and can be easily implemented for monitoring prokaryotic and eukaryotic entities present in the air of urban areas. IMPORTANCE Detection, monitoring, and characterization of the wide diversity of biological entities present in the air are difficult tasks that require time and expertise in different disciplines. We have evaluated the use of the Hirst spore trap (an instrument broadly employed in aerobiological studies) to detect and identify these organisms by DNA-based analyses. Our results showed a consistent collection of DNA and a good concordance with traditional methods for identification, suggesting that these devices can be used as a tool for continuous monitoring of the airborne biodiversity, improving taxonomic resolution and characterization together. They are also suitable for acquiring novel DNA amplicon-based information in order to gain a better understanding of the biological particles present in a scarcely known environment such as the air. PMID:28455334

  12. An Automated Air Sampling System Comprising an OPTIC GC Injector II, Quantification of VX Vapour

    DTIC Science & Technology

    2006-01-01

    Convention in 1989. In 1990 a Canadian research institute reported their work on the thermodesorption of VX using Tenax minitubes [3]. They obtained best...is to convert VX to a volatile derivative which is then trapped on Tenax and easily desorbed. This approach is used by Robert B. Walton [4] in...measure levels of 0.001 mg/m3 with a 20 minutes sampling time. With the Hapsite as well as with the abovementioned minitubes no cold trap is used

  13. Electrical properties of lunar soil dependence on frequency, temperature and moisture.

    NASA Technical Reports Server (NTRS)

    Strangway, D. W.; Chapman, W. B.; Olhoeft, G. R.; Carnes, J.

    1972-01-01

    It was found that the dielectric constant and loss tangent of lunar soil samples in the range from 100 Hz to 1 MHz are not strongly dependent on frequency provided care is taken to avoid exposure of the sample to atmospheric air containing moisture. The loss tangent value obtained is lower by nearly a factor 10 than any previously reported value. The measurement data imply that the surface layers of the moon are probably extremely transparent to radiowaves.

  14. TEM Study of SAFARI-2000 Aerosols

    NASA Technical Reports Server (NTRS)

    Buseck, Peter R.

    2004-01-01

    The aim of our research was to obtain data on the chemical and physical properties of individual aerosol particles from biomass smoke plume s in southern Africa and from air masses in the region that are affec ted by the smoke. We used analytical transmission electron microscopy (ATEM), including energy-dispersive X-ray spectrometry (EDS) and ele ctron energy-loss spectroscopy (EELS), and field-emission electron microscopy (FESEM) to study aerosol particles from several smoke and haz e samples and from a set of cloud samples.

  15. Mercury Pollution Exploration in Latvia with High-Sensitivity Zeeman Atomic Absorption Spectrometry

    NASA Astrophysics Data System (ADS)

    Bogans, Egils; Gavare, Zanda; Svagere, Anda; Poikane, Rita; Skudra, Jānis

    2011-01-01

    This research presents Hg pollution measurements performed in Latvia with sensitive method using Zeeman AAS analyzer RA-915+ and necessary attachments. Air in Riga city and water samples from a number of rivers and lakes of Latvia were analyzed for presence of low-level Hg concentrations. Ombrotrophic bog peat was analyzed to get insight into long-term trends. Environment in the sites sampled is relatively clean according to the results obtained, but there are local spots of pollution.

  16. Installation Restoration Program. Phase 2. Confirmation/Quantification. Stage 1. Air Force Plant 38, Porter, New York

    DTIC Science & Technology

    1988-04-01

    drainageways collect surface runoff at the plant and channel the water off plant property. These are: the Central Drain- age Ditch, the Magazine Ditch, and...past, this drain- age system collected test area deluge waters , small spills from test- ing areas, and drainage from around the flush and maintenance...Drain- age Ditch Table 4-2 shows the results of the analyses of two water samples and one soil/sediment sample that were obtained from the drainage from

  17. PM levels in urban area of Bejaia

    NASA Astrophysics Data System (ADS)

    Benaissa, Fatima; Maesano, Cara Nichole; Alkama, Rezak; Annesi-Maesano, Isabella

    2017-04-01

    Air pollution is not routinely measured in Bejaia City, Algeria, an urban area of around 200,000 inhabitants. We present first time measurements of particulate matter (PM) mass concentrations for this city (PM10, PM7, PM4, PM2.5 and PM1) over the course of one week, from July 8 to July 14, 2015. This study covered eight urban sampling sites and 169 measurements were obtained to determine mass concentration levels. Air pollution is not routinely measured in Bejaia City, Algeria, an urban area of around 200,000 inhabitants. We present first time measurements of particulate matter (PM) mass concentrations for this city (PM10, PM7, PM4, PM2.5 and PM1) over the course of one week, from July 8 to July 14, 2015. This study covered eight urban sampling sites and 169 measurements were obtained to determine mass concentration levels. The average city-wide PM10 and PM2.5 concentrations measured during this sampling were 87.8 ± 33.9 and 28.7 ± 10.6 µg/m3 respectively. These results show that particulate matter levels are high and exceed Algerian ambient air quality standards (maximum 80 µg/m3, without specifying the particle size). Further, PM10 and PM2.5 averages were well above the prescribed 24-hour average World Health Organization Air Quality Guidelines (WHO AQG) (50 µg/m3 for PM10 and 25 µg/m3 for PM2.5). The PM1, PM2,5, PM4 and PM7 fractions accounted for 15%, 32 %, 56% and 78% respectively of the PM10 measurements. Our analysis reveals that PM concentration variations in the study region were influenced primarily by traffic. In fact, lower PM10 concentrations (21.7 and 33.1 µg/m3) were recorded in residential sites while higher values (53.1, and 45.2 µg/m3) were registered in city centers. Keywords: Particulate matter, Urban area, vehicle fleet, Bejaia.

  18. Improved particle impactor assembly for size selective high volume air sampler

    DOEpatents

    Langer, G.

    1987-03-23

    Air containing entrained particulate matter is directed through a plurality of parallel, narrow, vertically oriented apertures of an inlet element toward an adjacently located, relatively large, dust impaction surface preferably covered with an adhesive material. The air flow turns over the impaction surface, leaving behind, the relatively larger particles and passes through two elongate apertures defining the outer bounds of the impaction collection surface to pass through divergent passages which slow down and distribute the air flow, with entrained smaller particles, over a fine filter element that separates the fine particles from the air. By appropriate selection of dimensions and the number of inlet apertures air flow through the inlet element is provided a nonuniform velocity distribution with the lower velocities being obtained near the center of the inlet apertures, to separate out particles larger than a certain predetermined size on the impaction collection surface. The impaction collection surface, even in a moderately sized apparatus, is thus relatively large and permits the prolonged sampling of air for periods extending to four weeks. 6 figs.

  19. Transformation of silicate gels during heat treatment in air and in argon - Spectroscopic studies

    NASA Astrophysics Data System (ADS)

    Rokita, M.; Mozgawa, W.; Adamczyk, A.

    2014-07-01

    The sol-gel method offers the possibility of obtaining silicate materials with different chemical compositions. When using TEOS or other organic precursor to silica capable of hydrolysis and poly-condensation, it is possible to use inorganic or organic precursors to produce other ingredients. This paper presents results of studying two series of silicate sols with the addition of calcium, in which the molar ratio of calcium to silicon was Ca/Si = x/(100 - x), where x was, respectively, 0-40 (x = 0-control sample). The resulting gels were subjected to heat treatment, wherein the heating was carried out simultaneously in air or in argon. To study the various stages of transformation of the gels, IR spectroscopy was used as the main research method to observe gradual disappearance of bands associated with bonds typical of organic materials and formation of bands characteristic of Si-O-Si bridging bonds. Due to the amorphous or fine crystalline nature of the resulting material, as confirmed in XRD studies, the different bands on the IR spectra were characterized by large full width at half maximum, hence an attempt was made to decompose the spectra into component bands. The analytic parameters of the resulting bands warranted the conclusion that there had been structural changes caused by the varying synthesis parameters. A comparison of the sol spectra after heat treatment in air and in argon at different temperatures showed a clear decrease in the full width at half maximum in the case of bands of samples with calcium content x ⩾ 30. The resulting spectra were compared with spectra of crystalline tobermorite, quartz and pseudowollastonite, which suggested the possibility of existence of areas with quartz-like ordering in the case of materials with calcium content x ⩾ 20 for the samples heated in argon and areas with pseudowollastonite-like ordering in the case of materials with calcium content x ⩾ 10 for the samples heated in air atmosphere. The conclusions drawn on the basis of infrared spectra were confirmed by XRD - prolonged heating of gels at 700 °C allowed us to obtain fine quartz and pseudowollastonite.

  20. In situ Carbon 13 and Oxygen 18 Ratios of Atmospheric CO2 from Cape Grim\\, Tasmania\\, Australia,1982-1993 (DB1014)

    DOE Data Explorer

    Francey, R. J. [CSIRO Division of Atmospheric Research, Mordialloc, Victoria, Australia; Allison, C. E. [CSIRO Division of Atmospheric Research, Mordialloc, Victoria, Australia

    1998-01-01

    Since 1982, a continuous program of sampling atmospheric CO2 to determine stable isotope ratios has been maintained at the Australian Baseline Air Pollution Station, Cape Grim, Tasmania (40°, 40'56"S, 144°, 41'18"E). The process of in situ extraction of CO2 from air, the preponderance of samples collected in conditions of strong wind from the marine boundary layer of the Southern Ocean, and the determination of all isotope ratios relative to a common high purity CO2 reference gas with isotopic δ13C close to atmospheric values, are a unique combination of factors with respect to obtaining a globally representative signal from a surface site. Air samples are collected during baseline condition episodes at a frequency of around one sample per week. Baseline conditions are characterized by wind direction in the sector 190°-280°, condensation nucleus concentration below 600 per cm-3, and steady continuous CO2 concentrations (variation ± 0.2 ppmv per hour). A vacuum pump draws air from either the 10 m or 70 m intakes and sampling alternates between the two intakes. The air from the intake is dried with a trap immersed in an alcohol bath at about -80°C. Mass spectrometer analyses for δ13C and δ18O are carried out by CSIRO's Division of Atmospheric Research in Aspendale, usually one to three weeks following collection. This record is possibly the most accurate representation of global atmospheric 13C behavior over the last decade and may be used to partition the uptake of fossil-fuel carbon emissions between ocean and terrestrial plant reservoirs. Using these data, Francey et al. (1995) observed a gradual decrease in δ13C from 1982 to 1993, but with a pronounced flattening from 1988 to 1990; a trend that appears to involve the terrestrial carbon cycle.

  1. Determination and comparison of microbial loads in atmospheres of two hospitals in Izmir, Turkey.

    PubMed

    Aydin Çakir, Nergüze; Uçar, Füsun Bahriye; Haliki Uztan, Alev; Corbaci, Cengiz; Akpinar, Onur

    2013-01-01

    Nosocomial infections, also known as hospital-acquired infections, has become one of the most important health problems in health care units worldwide. The presented study aims to determine the average amount of microorganism loads and to show that the atmospheres of the two hospitals can be a potential source regarding nosocomial infections. The effect of surface and floor disinfection processes in the two hospitals and the antibiotic susceptibility of the bacterial isolates were also evaluated. Microorganisms were isolated from air samples collected from different areas (patient wards, corridors, operating theatres and postoperative units) of the two hospitals in Izmir. Sampling was conducted between December 2006 - March 2007. During the 3-month sampling period, the average number of live microorganisms in the air samples collected from second-class environments in the hospital 1 and the hospital 2 was found to be 224.44 and 536.66 cfu/m(3) , respectively. The average number of microorganisms in hospital 2 collected before the disinfection process was higher than those after the disinfection process. However, because of the closure of the air-conditioning system and the hepa filters after the disinfection process, this was reversed in hospital 1. In total, 54 and 42 isolates were obtained from hospital 1 and hospital 2, respectively. 49 isolates from hospital 1 and 35 isolates from hospital 2 were identified as Staphylacoccus sp. The remaining isolates were identified as Aerococcus sp. and Enterococcus sp. Pseudomonas sp. was not determined in the air samples of the two hospitals. It was detected that the microbial loads in the atmospheres of the two hospitals studied varied greatly depending on the number of people in the environment. As the results indicate, the total number of microorganisms in the atmospheres of operating theatres in both hospitals does not pose a threat according to the Air Microbe Index.

  2. NASA Global Atmospheric Sampling Program (GASP). Data report for tape VL0001. [data management and data retrieval of information from environmental surveys

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.; Lezberg, E. A.

    1976-01-01

    Atmospheric trace constituents in the upper troposphere and lower stratosphere are now being measured as part of the NASA Global Atmospheric Sampling Program (GASP), using fully automated air sampling systems on board commercial 747 aircraft in routine airline service. Measurements of atmospheric ozone and related meteorological and flight information obtained during several GASP flights in March 1975 are now available from the National Climatic Center, Asheville, North Carolina. In addition to the data from the aircraft, tropopause pressure data obtained from the National Meteorological Center (NMC) archives for the dates of the flights are included. This report is the first of a series of reports which describes the data currently available from GASP, including flight routes and dates, instrumentation, the data processing procedure used, and data tape specifications.

  3. Effects of atmospheric moisture on rock resistivity.

    NASA Technical Reports Server (NTRS)

    Alvarez, R.

    1973-01-01

    This study examines the changes in resistivity of rock samples as induced by atmospheric moisture. Experiments were performed on samples of hematitic sandstone, pyrite, and galena. The sandstone underwent a change in resistivity of four orders of magnitude when it was measured in a vacuum of 500 ntorr and in air of 37% relative humidity. Pyrite and galena showed no variations in resistivity when they were measured under the same conditions. These results, plus others obtained elsewhere, indicate that rocks of the resistive type are affected in their electrical properties by atmospheric moisture, whereas rocks of the conductive type are not. The experimental evidence obtained is difficult to reconcile with a model of aqueous electrolytic conduction on the sample surface. It is instead suggested that adsorbed water molecules alter the surface resistivity in a manner similar to that observed in semiconductors and insulators.

  4. Optical molecular fluorescence determination of ultra-trace beryllium in occupational and environmental samples using highly alkaline conditions

    PubMed Central

    Adams, Lori; Agrawal, Anoop; Cronin, John P.; Ashley, Kevin

    2017-01-01

    Exposures to beryllium (Be), even at extremely low levels, can cause severe health effects in a percentage of those exposed; consequently, occupational exposure limits (OELs) promulgated for this element are the lowest established for any element. This work describes the advantages of using highly alkaline dye solutions for determination of Be in occupational hygiene and environmental samples by means of an optical molecular fluorescence technique after sample extraction in 1–3% (w˖w−1) aqueous ammonium bifluoride (NH4HF2). Improved attributes include the ability to further enhance the detection limits of Be in extraction solutions of high acidity with minimal dilution, which is particularly beneficial when NH4HF2 solutions of higher concentration are used for extraction of Be from soil samples. Significant improvements in Be method detection limits (MDLs) are obtained at levels many-fold below those reported previously for this methodology. Notably, MDLs for Be of <0.01 ng l−1 / 0.1 ng per sample have been attained, which are superior to MDLs routinely reported for this element by means of the most widely used ultra-trace elemental measurement technique, inductively coupled plasma mass spectrometry (ICP-MS). Very low MDLs for Be are essential in consideration of reductions in OELs for this element in workplace air by health organizations and regulatory agencies in the USA and internationally. Applications of enhanced Be measurements to air filter samples, surface wipe samples, soils and newly-designed occupational air sampler inserts are illustrated. PMID:28626294

  5. Evaluation of passive diffusion bag samplers, dialysis samplers, and nylon-screen samplers in selected wells at Andersen Air Force Base, Guam, March-April 2002

    USGS Publications Warehouse

    Vroblesky, Don A.; Joshi, Manish; Morrell, Jeff; Peterson, J.E.

    2003-01-01

    During March-April 2002, the U.S. Geological Survey, Earth Tech, and EA Engineering, Science, and Technology, Inc., in cooperation with the Air Force Center for Environmental Excellence, tested diffusion samplers at Andersen Air Force Base, Guam. Samplers were deployed in three wells at the Main Base and two wells at Marianas Bonins (MARBO) Annex as potential ground-water monitoring alternatives. Prior to sampler deployment, the wells were tested using a borehole flowmeter to characterize vertical flow within each well. Three types of diffusion samplers were tested: passive diffusion bag (PDB) samplers, dialysis samplers, and nylon-screen samplers. The primary volatile organic compounds (VOCs) tested in ground water at Andersen Air Force Base were trichloroethene and tetrachloroethene. In most comparisons, trichloroethene and tetrachloroethene concentrations in PDB samples closely matched concentrations in pumped samples. Exceptions were in wells where the pumping or ambient flow produced vertical translocation of water in a chemically stratified aquifer. In these wells, PDB samplers probably would be a viable alternative sampling method if they were placed at appropriate depths. In the remaining three test wells, the trichloroethene or tetrachloroethene concentrations obtained with the diffusion samplers closely matched the result from pumped sampling. Chloride concentrations in nylon-screen samplers were compared with chloride concentrations in dialysis and pumped samples to test inorganic-solute diffusion into the samplers across a range of concentrations. The test showed that the results from nylon-screen samplers might have underestimated chloride concentrations at depths with elevated chloride concentrations. The reason for the discrepancy in this investigation is unknown, but may be related to nylon-screen-mesh size, which was smaller than that used in previous investigations.

  6. Atmospheric CO2 Records from Sites in the Main Geophysical Observatory Air Sampling Network (1983 - 1993)

    DOE Data Explorer

    Brounshtein, A. M. [Main Geophysical Observatory, St. Petersburg, Russia; Shaskov, A. A. [Main Geophysical Observatory, St. Petersburg, Russia; Paramonova, N. N. [Main Geophysical Observatory, St. Petersburg, Russia; Privalov, V. I. [Main Geophysical Observatory, St. Petersburg, Russia; Starodubtsev, Y. A. [Main Geophysical Observatory, St. Petersburg, Russia

    1997-01-01

    Air samples were collected from five sites in the Main Geophysical Observatory air sampling network to monitor the atmospheric CO2 from 1983 - 1993. Airwas collected generally four times per month in pairs of 1.5-L stainless steel electropolished flasks with one greaseless stainless steel stopcock. Sampling was performed by opening the stopcock of the flasks, which have been evacuated at the central laboratory at the Main Geophysical Observatory (MGO). The air was not dried during sample collection. Attempts were made to obtain samples when the wind speed was >5 m/s and the wind direction corresponded to the predetermined "clean air" sector. The period of record at Bering Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Bering Island rose from approximately 346 parts per million by volume (ppmv) in 1986 to 362.6 ppmv in 1993. Measurements from this station are considered indicative of maritime air masses. The period of record at Kotelny Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Kotelny Island rose from 356.08 parts per million by volume (ppmv) in 1988 to 358.8 ppmv in 1993. Because Kotelny Island is the northernmost Russian sampling site, measurements from this site serve as a useful comparison to other northern sites (e.g., Alert, Northwest Territories). In late 1989, air sampling began at the Russian site of Kyzylcha, located in the Republic of Uzbekistan. Unfortunately, the desert site at Kyzylcha has been out of operation since mid-1991 due to financial difficulties in Russia. The annual mean value of 359.02 parts per million by volume (ppmv) for 1990, the lone full year of operation, is higher than measurements from other monitoring programs at this latitude [e.g., Niwot Ridge (354.7 ppmv in 1990) and Tae-ahn Peninsula]. Station "C," an open ocean site, in the North Atlantic, east of Greenland, was established in 1968 and was operated in cooperation with NOAA's National Weather Service through 1973. The Main Geophysical Observatory collected flask samples at the site from January 1983 through October 1990. The yearly mean atmospheric CO concentration at Station "C" rose from 348.15 parts per million by volume (ppmv) in 1985 to 354.33 ppmv in 1989. The period of record at Teriberka Station is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Teriberka Station rose from 354.8 parts per million by volume (ppmv) in 1989 to 358.7 ppmv in 1993.

  7. New archeointensity results from the reconstructed ancient kiln by the Tsunakawa-Shaw method

    NASA Astrophysics Data System (ADS)

    Yamamoto, Y.; Hatakeyama, T.; Kitahara, Y.; Saito, T.

    2017-12-01

    Yamamoto et al. (2015) reported that baked clay samples from the floor of a reconstructed ancient kiln provided a reliable Tsunakawa-Shaw (LTD-DHT Shaw) archeointensity (AI) estimate of 47.3 +/- 2.2 microT which is fairly consistent with the in situ geomagnetic field of 46.4 microT at the time of the reconstruction. The reconstruction was conducted to reproduce an excavated kiln of the seventh century in Japan and Sue-type potteries of contemporary style were also fired (Nakajima et al., 1974). Two of the potteries with reddish color were recently subjected to the Tsunakawa-Shaw archeointensity determinations, resulting in reliable AI estimates of 45.4 +/- 2.3 (N=6) and 48.2 +/- 2.7 microT (N=15) when specimens were heated in air in laboratory (Yamamoto et al., 2017 JpGU-AGU Joint Meeting). We have had another opportunity to take samples from a new reconstructed ancient kiln in Japan which was fired in autumn 2016. The samples were two Sue-type potteries with grayish color (bowl-type and plate-type) and some blocks collected from inner wall of the kiln body. They were cut into mini specimens and then subjected to the Tsunakawa-Shaw experiment. Heating in laboratory was done either in air or vacuum.For the bowl-type pottery, AIs of 46.9 +/- 2.8 (N=6, air) and 45.3 +/- 2.3 microT (N=6, vacuum) are obtained. They are indistinguishable each other and consistent with the IGRF field of 47.4 microT at the reconstructed location in 2016. For the plate-type pottery, AIs result in 41.8 +/- 1.3 (N=4, air) and 43.9 +/- 3.9 microT (N=4, vacuum). They are also indistinguishable each other but the former AI is slightly lower than the IGRF field.For the inner wall, AIs of 45.0 (N=1, air) and 46.8 microT (N=1, vacuum) are obtained from a right-side wall, and those of 45.5 +/- 2.5 (N=2, air) and 47.7 +/- 3.0 microT (N=2, vacuum) are observed from a left-side wall. They are all indistinguishable and consistent with the IGRF field.

  8. A measurement system for the atmospheric trace gases CH4 and CO

    NASA Technical Reports Server (NTRS)

    Condon, E. P.

    1977-01-01

    A system for measuring ambient clean air levels of the atmospheric trace gases methane and carbon monoxide is described. The analytical method consists of a gas chromatographic technique that incorporates sample preconcentration with catalytic conversion of CO to CH4 and subsequent flame ionization detection of these gases. The system has sufficient sensitivity and repeatability to make the precise measurements required to establish concentration profiles for CO and CH4 in the planetary boundary layer. A discussion of the bottle sampling program being conducted to obtain the samples for the concentration profiles is also presented.

  9. The atmospheric inventory of Xenon and noble cases in shales The plastic bag experiment

    NASA Technical Reports Server (NTRS)

    Bernatowicz, T. J.; Podosek, F. A.; Honda, M.; Kramer, F. E.

    1984-01-01

    A novel trapped gas analysis protocol is applied to five shales in which the samples are sealed in air to eliminate the possibility of gas loss in the preanalysis laboratory vacuum exposure of a conventional protocol. The test is aimed at a determination concerning the hypothesis that atmospheric noble gases occur in the same proportion as planetary gases in meteorites, and that the factor-of-23 deficiency of air Xe relative to planetary Xe is made up by Xe stored in shales or other sedimentary rocks. The results obtained do not support the shale hypothesis.

  10. Improved pressurized Marinelli beaker measurements of radioactive xenon in air.

    PubMed

    Robinson, Troy; Mann, Nick; Houghton, Tracy; Watrous, Matthew; Peterson, John; Fabian, Paul; Hipp, Pat; Reavis, Mark; Fernandez, Francisco

    2017-08-01

    INL has shown that a Marinelli beaker geometry can be used for the measurement of radioactive xenon in air using an aluminum Marinelli. A carbon fiber Marinelli was designed and constructed to improve overall performance. This composite Marinelli can withstand sample pressures of 276bar and achieve approximately a 4x performance improvement in the minimum detectable concentrations (MDCs) and concentration uncertainties. The MDCs obtained during a 24h assay for 133 Xe, 131m Xe, and 135 Xe are: 1.4, 13, and 0.35Bq/m 3 . Copyright © 2016. Published by Elsevier Ltd.

  11. Volatilizable Biogenic Organic Compounds (VBOCs) with two dimensional Gas Chromatography-Time of Flight Mass Spectrometry (GC × GC-TOFMS): sampling methods, VBOC complexity, and chromatographic retention data

    NASA Astrophysics Data System (ADS)

    Pankow, J. F.; Luo, W.; Melnychenko, A. N.; Barsanti, K. C.; Isabelle, L. M.; Chen, C.; Guenther, A. B.; Rosenstiel, T. N.

    2012-02-01

    Two dimensional gas chromatography (GC × GC) with detection by time-of-flight mass spectrometry (TOFMS) was applied in the rapid analysis of air samples containing highly complex mixtures of volatilizable biogenic organic compounds (VBOCs). VBOC analytical methodologies are briefly reviewed, and optimal conditions are discussed for sampling with both adsorption/thermal desorption (ATD) cartridges and solid-phase microextraction (SPME) fibers. Air samples containing VBOC emissions from leaves of two tree species (Cedrus atlantica and Calycolpus moritzianus) were obtained by both ATD and SPME. The optimized gas chromatographic conditions utilized a 45 m, 0.25 mm I.D. low-polarity primary column (DB-VRX, 1.4 μm film) and a 1.5 m, 0.25 mm I.D. polar secondary column (StabilwaxTM, 0.25 μm film). Excellent separation was achieved in a 36 min temperature programmed GC × GC chromatogram. Thousands of VBOC peaks were present in the sample chromatograms; hundreds of tentative identifications by NIST mass spectral matching are provided. Very few of the tentatively identified compounds are currently available as authentic standards. Minimum detection limit values for a 5 l ATD sample were 3.5 pptv (10 ng m-3) for isoprene, methyl vinyl ketone, and methacrolein, and ~1.5 pptv (~10 ng m-3) for monoterpenes and sesquiterpenes. Kovats-type chromatographic retention index values on the primary column and relative retention time values on the secondary column are provided for 21 standard compounds and for 417 tentatively identified VBOCs. 19 of the 21 authentic standard compounds were found in one of the Cedrus atlantica SPME samples. In addition, easily quantifiable levels of at least 13 sesquiterpenes were found in an ATD sample obtained from a branch enclosure of Calycolpus moritzianus. Overall, the results obtained via GC × GC-TOFMS highlight an extreme, and largely uncharacterized diversity of VBOCs, consistent with the hypothesis that sesquiterpenes and other compounds beyond the current list of typically determined VBOC analytes may well be important contributors to global atmospheric levels of organic particulate matter.

  12. Volatilizable biogenic organic compounds (VBOCs) with two dimensional gas chromatography-time of flight mass spectrometry (GC × GC-TOFMS): sampling methods, VBOC complexity, and chromatographic retention data

    NASA Astrophysics Data System (ADS)

    Pankow, J. F.; Luo, W.; Melnychenko, A. N.; Barsanti, K. C.; Isabelle, L. M.; Chen, C.; Guenther, A. B.; Rosenstiel, T. N.

    2011-06-01

    Two dimensional gas chromatography (GC × GC) with detection by time-of-flight mass spectrometry (TOFMS) was applied in the rapid analysis of air samples containing highly complex mixtures of volatilizable biogenic organic compounds (VBOCs). VBOC analytical methodologies are briefly reviewed, and optimal conditions are discussed for sampling with both adsorption/thermal desorption (ATD) cartridges and solid-phase microextraction (SPME) fibers. Air samples containing VBOC emissions from leaves of two tree species (Cedrus atlantica and Calycolpus moritzianus) were obtained by both ATD and SPME. The optimized gas chromatographic conditions utilized a 45 m, 0.25 mm I.D. low-polarity primary column (DB-VRX, 1.4 μm film) and a 1.5 m, 0.25 mm I.D. polar secondary column (Stabilwax® 0.25 μm film). Excellent separation was achieved in a 36 min temperature programmed GC × GC chromatogram. Thousands of VBOC peaks were present in the sample chromatograms; hundreds of tentative identifications by NIST mass spectral matching are provided. Very few of the tentatively identified compounds are currently available as authentic standards. Method detection limit values for a 5 l ATD sample were 3.5 pptv (10 ng m-3) for isoprene, methyl vinyl ketone, and methacrolein, and ~1.5 pptv (~10 ng m-3) for monoterpenes and sesquiterpenes. Kovats-type chromatographic retention index values on the primary column and relative retention time values on the secondary column are provided for 21 standard compounds and for 417 tentatively identified VBOCs. 19 of the 21 authentic standard compounds were found in one of the Cedrus atlantica SPME samples. In addition, easily quantifiable levels of at least 13 sesquiterpenes were found in an ATD sample obtained from a branch enclosure of Calycolpus moritzianus. Overall, the results obtained via GC × GC-TOFMS highlight an extreme, and largely uncharacterized diversity of VBOCs, consistent with the hypothesis that sesquiterpenes and other compounds beyond the current list of typically determined VBOC analytes may well be important contributors to global atmospheric levels of organic particulate matter.

  13. RECENT XPS STUDIES OF THE EFFECT OF PROCESSING ON NB SRF SURFACES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hui Tian; Binping Xiao; Michael Kelley

    XPS studies have consistently shown that Nb surfaces for SRF chiefly comprise of a few nm of Nb2O5 on top of Nb metal, with minor amounts of Nb sub-oxides. Nb samples after BCP/EP treatment with post-baking at the various conditions have been examined by using synchrotron based XPS. Despite the confounding influence of surface roughness, certain outcomes are clear. Lower-valence Nb species are always and only associated with the metal/oxide interface, but evidence for an explicit layer structure or discrete phases is lacking. Post-baking without air exposure shows decreased oxide layer thickness and increased contribution from lower valence species, butmore » spectra obtained after subsequent air exposure cannot be distinguished from those obtained prior to baking, though the SRF performance improvement remains.« less

  14. Effect of Sampling Depth on Air-Sea CO2 Flux Estimates in River-Stratified Arctic Coastal Waters

    NASA Astrophysics Data System (ADS)

    Miller, L. A.; Papakyriakou, T. N.

    2015-12-01

    In summer-time Arctic coastal waters that are strongly influenced by river run-off, extreme stratification severely limits wind mixing, making it difficult to effectively sample the surface 'mixed layer', which can be as shallow as 1 m, from a ship. During two expeditions in southwestern Hudson Bay, off the Nelson, Hayes, and Churchill River estuaries, we confirmed that sampling depth has a strong impact on estimates of 'surface' pCO2 and calculated air-sea CO2 fluxes. We determined pCO2 in samples collected from 5 m, using a typical underway system on the ship's seawater supply; from the 'surface' rosette bottle, which was generally between 1 and 3 m; and using a niskin bottle deployed at 1 m and just below the surface from a small boat away from the ship. Our samples confirmed that the error in pCO2 derived from typical ship-board versus small-boat sampling at a single station could be nearly 90 μatm, leading to errors in the calculated air-sea CO2 flux of more than 0.1 mmol/(m2s). Attempting to extrapolate such fluxes over the 6,000,000 km2 area of the Arctic shelves would generate an error approaching a gigamol CO2/s. Averaging the station data over a cruise still resulted in an error of nearly 50% in the total flux estimate. Our results have implications not only for the design and execution of expedition-based sampling, but also for placement of in-situ sensors. Particularly in polar waters, sensors are usually deployed on moorings, well below the surface, to avoid damage and destruction from drifting ice. However, to obtain accurate information on air-sea fluxes in these areas, it is necessary to deploy sensors on ice-capable buoys that can position the sensors in true 'surface' waters.

  15. Evaluation of a Gas Chromatograph-Differential Mobility Spectrometer for Potential Water Monitoring on the International Space Station

    NASA Technical Reports Server (NTRS)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2015-01-01

    Environmental monitoring for manned spaceflight has long depended on archival sampling, which was sufficient for short missions. However, the longer mission durations aboard the International Space Station (ISS) have shown that enhanced, real-time monitoring capabilities are necessary in order to protect both the crewmembers and the spacecraft systems. Over the past several years, a number of real-time environmental monitors have been deployed on the ISS. Currently, volatile organic compounds (VOCs) in the station air are monitored by the Air Quality Monitor (AQM), a small, lightweight gas chromatograph-differential mobility spectrometer. For water monitoring, real-time monitors are used for total organic carbon (TOC) and biocide analysis. No information on the actual makeup of the TOC is provided presently, however. An improvement to the current state of environmental monitoring could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for VOCs in air samples, this instrument provides a logical starting point to evaluate the feasibility of this approach. The major hurdle for this effort lies in the liberation of the target analytes from the water matrix. In this presentation, we will discuss our recent studies, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target VOCs at the concentrations at which they are routinely detected in archival water samples from the ISS. We will compare the results of these studies with those obtained from the instrumentation routinely used to analyze archival water samples.

  16. Optimizing integrated airport surface and terminal airspace operations under uncertainty

    NASA Astrophysics Data System (ADS)

    Bosson, Christabelle S.

    In airports and surrounding terminal airspaces, the integration of surface, arrival and departure scheduling and routing have the potential to improve the operations efficiency. Moreover, because both the airport surface and the terminal airspace are often altered by random perturbations, the consideration of uncertainty in flight schedules is crucial to improve the design of robust flight schedules. Previous research mainly focused on independently solving arrival scheduling problems, departure scheduling problems and surface management scheduling problems and most of the developed models are deterministic. This dissertation presents an alternate method to model the integrated operations by using a machine job-shop scheduling formulation. A multistage stochastic programming approach is chosen to formulate the problem in the presence of uncertainty and candidate solutions are obtained by solving sample average approximation problems with finite sample size. The developed mixed-integer-linear-programming algorithm-based scheduler is capable of computing optimal aircraft schedules and routings that reflect the integration of air and ground operations. The assembled methodology is applied to a Los Angeles case study. To show the benefits of integrated operations over First-Come-First-Served, a preliminary proof-of-concept is conducted for a set of fourteen aircraft evolving under deterministic conditions in a model of the Los Angeles International Airport surface and surrounding terminal areas. Using historical data, a representative 30-minute traffic schedule and aircraft mix scenario is constructed. The results of the Los Angeles application show that the integration of air and ground operations and the use of a time-based separation strategy enable both significant surface and air time savings. The solution computed by the optimization provides a more efficient routing and scheduling than the First-Come-First-Served solution. Additionally, a data driven analysis is performed for the Los Angeles environment and probabilistic distributions of pertinent uncertainty sources are obtained. A sensitivity analysis is then carried out to assess the methodology performance and find optimal sampling parameters. Finally, simulations of increasing traffic density in the presence of uncertainty are conducted first for integrated arrivals and departures, then for integrated surface and air operations. To compare the optimization results and show the benefits of integrated operations, two aircraft separation methods are implemented that offer different routing options. The simulations of integrated air operations and the simulations of integrated air and surface operations demonstrate that significant traveling time savings, both total and individual surface and air times, can be obtained when more direct routes are allowed to be traveled even in the presence of uncertainty. The resulting routings induce however extra take off delay for departing flights. As a consequence, some flights cannot meet their initial assigned runway slot which engenders runway position shifting when comparing resulting runway sequences computed under both deterministic and stochastic conditions. The optimization is able to compute an optimal runway schedule that represents an optimal balance between total schedule delays and total travel times.

  17. Circumventing shallow air contamination in Mid Ocean Ridge Basalts

    NASA Astrophysics Data System (ADS)

    Mukhopadhyay, Sujoy; Parai, Rita; Tucker, Jonathan; Middleton, Jennifer; Langmuir, Charles

    2016-04-01

    Noble gases in mantle-derived basalts provide a rich portrait of mantle degassing and surface-interior volatile exchange. However, the ubiquity of shallow-level air contamination frequently obscures the mantle noble gas signal. In a majority of samples, shallow air contamination dominates the noble gas budget. As a result, reconstructing the variability in heavy noble gas mantle source compositions and inferring the history of deep recycling of atmospheric noble gases is difficult. For example, in the gas-rich popping rock 2ΠD43, 129Xe/130Xe ratios reach 7.7±0.23 in individual step-crushes, but the bulk composition of the sample is close to air (129Xe/130Xe of 6.7). Here, we present results from experiments designed to elucidate the source of shallow air contamination in MORBs. Step-crushes were carried out to measure He, Ne, Ar and Xe isotopic compositions on two aliquots of a depleted popping glass that was dredged from between the Kane and Atlantis Fracture Zones of the Mid-Atlantic Ridge in May 2012. One aliquot was sealed in ultrapure N2 after dredge retrieval, while the other aliquot was left exposed to air for 3.5 years. The bulk 20Ne/22Ne and 129Xe/130Xe ratios measured in the aliquot bottled in ultrapure N2 are 12.3 and 7.6, respectively, and are nearly identical to the estimated mantle source values. On the other hand, step crushes in the aliquot left exposed to air for several years show Ne isotopic compositions that are shifted towards air, with a bulk 20Ne/22Ne of 11.5; the bulk 129Xe/130Xe, however, was close to 7.6. These results indicate that lighter noble gases exchange more efficiently between the bubbles trapped in basalt glass and air, suggesting a diffusive or kinetic mechanism for the incorporation of the shallow air contamination. Importantly, in Ne-Ar or Ar-Xe space, step-crushes from the bottled aliquot display a trend that can be easily fit with a simple two-component hyperbolic mixing between mantle and atmosphere noble gases. Step-crushes in the aliquot left exposed to air display significantly more scatter, which makes it difficult to fit a two-component mixing hyperbola and obtain the mantle source value for this aliquot. In summary, our simple and inexpensive experiment demonstrates that at least in some samples, significant air contamination is added after dredge retrieval from the ocean floor. Bottling samples in ultrapure N2 upon dredge retrieval can largely eliminate this component of shallow-level air contamination. As a result, the number of step crushes required to characterize a sample decreases and estimating the mantle source compositions of the basalts becomes significantly easier, which in turn leads to more refined estimates of mantle degassing and regassing rates.

  18. Microbiological contamination of compressed air used in dentistry: an investigation.

    PubMed

    Conte, M; Lynch, R M; Robson, M G

    2001-11-01

    The purpose of this preliminary investigation was twofold: 1) to examine the possibility of cross-contamination between a dental-evacuation system and the compressed air used in dental operatories and 2) to capture and identify the most common microflora in the compressed-air supply. The investigation used swab, water, and air sampling that was designed to track microorganisms from the evacuation system, through the air of the mechanical room, into the compressed-air system, and back to the patient. Samples taken in the vacuum system, the air space in the mechanical room, and the compressed-air storage tank had significantly higher total concentrations of bacteria than the outside air sampled. Samples of the compressed air returning to the operatory were found to match the outside air sample in total bacteria. It was concluded that the air dryer may have played a significant role in the elimination of microorganisms from the dental compressed-air supply.

  19. Meteorological and operational aspects of 46 clear air turbulent sampling missions with an instrumented B-57B aircraft. Volume 2, appendix C: Turbulence missions

    NASA Technical Reports Server (NTRS)

    Waco, D. E.

    1979-01-01

    The results of 46 clear air turbulence (CAT) probing missions conducted with an extensively instrumented B-57B aircraft are summarized from a meteorological viewpoint in a two-volume technical memorandum. The missions were part of the NASA Langley Research Center's MAT (Measurement of Atmospheric Turbulence) program, which was conducted between March 1974, and September 1975, at altitudes ranging up to 15 km. Turbulence samples were obtained under diverse conditions including mountain waves, jet streams, upper level fronts and troughs, and low altitude mechanical and thermal turbulence. CAT was encountered on 20 flights comprising 77 data runs. In all, approximately 4335 km were flown in light turbulence, 1415 km in moderate turbulence, and 255 km in severe turbulence during the program.

  20. Particulate matter and polycyclic aromatic hydrocarbons in a selected athletic hall: ambient concentrations, origin and effects on human health

    NASA Astrophysics Data System (ADS)

    Kuskowska, Karolina; Rogula-Kozłowska, Wioletta; Rogula-Kopiec, Patrycja

    2018-01-01

    The paper presents the results of research on the concentration of 16 polycyclic aromatic hydrocarbons (PAHs) associated with total suspended particles (TSP) and their respirable fraction (PM4) in one of the Warsaw sports halls. Samples of dust were collected for 15 days simultaneously inside and outside (atmospheric air) of the sports hall. The obtained data allowed calculating diagnostic ratios indicating the origin of the PAHs and selected indicators of cumulative exposure to the PAH mixture. Both PM and PAH in the surveyed area were derived from the combustion of solid fuels; this involved pollution both in the atmospheric air and in the air inside the sports hall. It has been shown that the exposure of sports hall users to PAHs is significantly higher than the exposure resulting from concentrations recorded in the atmospheric air.

  1. Diagnosing AIRS Sampling with CloudSat Cloud Classes

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric; Yue, Qing; Guillaume, Alexandre; Kahn, Brian

    2011-01-01

    AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.

  2. Quantitative assessment of mycological air pollution in selected rooms of residential and dormitory housing facilities.

    PubMed

    Lonc, Elzbieta; Plewa, Kinga; Kiewra, Dorota; Szczepańska, Anna; Firling, Conrad E

    2013-01-01

    The qualitative and quantitative mycological composition of indoor areas of three private residencies and an academic dormitory in Wroclaw, Poland was investigated. Seasonal fungal samples were obtained using a MAS-100 air sampler. The samples were cultured on three different media: Sabouraud Agar (SAB), Dichloran Glycerol Selective Medium (DG18) and Malt Extract Agar (MEA). The number of colony forming unit (CFU) values ranged from 10 CFU/m3 to 490 CFU/m3 depending on the culture medium, season, and sampling site. The identification of the cultured fungi was performed using macro- and microscopic observations and diagnostic keys. Eleven fungal genera were identified. The most common fungi were members of genera Cladosporium, Penicillium, Aspergillus, Alternaria, and Fusarium; the least common fungi were members of genera Geotrichum and Paecilomyces. Seasonal variations in the concentration of fungi were observed with the highest concentration of fungi in the spring and the lowest concentration of fungi in the winter. There were no statistically significant correlations between fungal concentrations and the temperature or the relative humidity of the sample sites.

  3. Non-contact evaluation of milk-based products using air-coupled ultrasound

    NASA Astrophysics Data System (ADS)

    Meyer, S.; Hindle, S. A.; Sandoz, J.-P.; Gan, T. H.; Hutchins, D. A.

    2006-07-01

    An air-coupled ultrasonic technique has been developed and used to detect physicochemical changes of liquid beverages within a glass container. This made use of two wide-bandwidth capacitive transducers, combined with pulse-compression techniques. The use of a glass container to house samples enabled visual inspection, helping to verify the results of some of the ultrasonic measurements. The non-contact pulse-compression system was used to evaluate agglomeration processes in milk-based products. It is shown that the amplitude of the signal varied with time after the samples had been treated with lactic acid, thus promoting sample destabilization. Non-contact imaging was also performed to follow destabilization of samples by scanning in various directions across the container. The obtained ultrasonic images were also compared to those from a digital camera. Coagulation with glucono-delta-lactone of skim milk poured into this container could be monitored within a precision of a pH of 0.15. This rapid, non-contact and non-destructive technique has shown itself to be a feasible method for investigating the quality of milk-based beverages, and possibly other food products.

  4. Characterization of γ-radiation induced polymerization in ethyl methacrylate and methyl acrylate monomers solutions

    NASA Astrophysics Data System (ADS)

    Baccaro, Stefania; Casieri, Cinzia; Cemmi, Alessia; Chiarini, Marco; D'Aiuto, Virginia; Tortora, Mariagrazia

    2017-12-01

    The present work is focused on the γ-radiation induced polymerization of ethyl methacrylate (EMA) and methyl acrylate (MA) monomers mixture to obtain a co-polymer with specific features. The effect of the irradiation parameters (radiation absorbed dose, dose rate) and of the environmental atmosphere on the features of the final products was investigated. Attenuated Total Reflectance - Fourier Transform Infrared Spectroscopy (ATR-FTIR) and Nuclear Magnetic Resonance high-resolution analyses of hydrogen and carbon nuclei (1H and 13C NMR) were applied to follow the γ-induced modifications by monitoring the co-polymerization process and allowed the irradiation parameters optimization. Diffusion-Ordered NMR (DOSY-NMR) data were used to evaluate the co-polymers polydispersity and polymerization degree. Since the last parameter is strongly influenced by the γ radiation and environmental conditions, a comparison among samples prepared and irradiated in air and under nitrogen atmosphere was carried out. In presence of oxygen, higher radiation was required to obtain a full solid co-polymer since a partial amount of energy released to the samples was involved in competitive processes, i.e. oxygen-containing free radicals formation and primary radicals recombination. Irrespectively to the environmental atmosphere, more homogeneous samples in term of polymerization degree dispersion was achieved at lower dose rates. At radiation absorbed doses higher than those needed for the formation of the co-polymer, while in case of samples irradiated in air heavy depolymerization was verified, a sensible increase of the samples stability was attained if the irradiation was performed under nitrogen atmosphere.

  5. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  6. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    PubMed Central

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  7. Biobriefcase aerosol collector

    DOEpatents

    Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2009-09-22

    A system for sampling air and collecting particles entrained in the air that potentially include bioagents. The system comprises providing a receiving surface, directing a liquid to the receiving surface and producing a liquid surface. Collecting samples of the air and directing the samples of air so that the samples of air with particles entrained in the air impact the liquid surface. The particles potentially including bioagents become captured in the liquid. The air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid but cause minor turbulence. The liquid surface has a surface tension and the collector samples the air and directs the air to the liquid surface so that the air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid, but cause minor turbulence on the surface resulting in insignificant evaporation of the liquid.

  8. Development and testing of a portable wind sensitive directional air sampler

    NASA Technical Reports Server (NTRS)

    Deyo, J.; Toma, J.; King, R. B.

    1975-01-01

    A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

  9. Formaldehyde exposure in gross anatomy laboratory of Suranaree University of Technology: a comparison of area and personal sampling.

    PubMed

    Saowakon, Naruwan; Ngernsoungnern, Piyada; Watcharavitoon, Pornpun; Ngernsoungnern, Apichart; Kosanlavit, Rachain

    2015-12-01

    Cadavers are usually preserved by embalming solution which is composed of formaldehyde (FA), phenol, and glycerol. Therefore, medical students and instructors have a higher risk of exposure to FA inhalation from cadavers during dissection. Therefore, the objective of this study was to evaluate the FA exposure in indoor air and breathing zone of medical students and instructors during dissection classes in order to investigate the relationship between them. The indoor air and personal air samples in breathing zone were collected three times during anatomy dissection classes (in January, August, and October of 2014) with sorbent tubes, which were analyzed by high-performance liquid chromatography (HPLC). The air cleaner machines were determined by weight measurement. Pulmonary function tests and irritation effects were also investigated. The mean of FA concentrations ranged from 0.117 to 0.415 ppm in the indoor air and from 0.126 to 1.176 ppm in the breathing zone of students and instructors. All the personal exposure data obtained exceeded the threshold limit of NIOSH and WHO agencies. The air cleaner machines were not significant difference. The pulmonary function of instructors showed a decrease during attention of classes and statistically significant decreasing in the instructors more than those of the students. Clinical symptoms that were observed in nose and eyes were irritations with general fatigue. We suggested that the modified exhaust ventilation and a locally ventilated dissection work table were considered for reducing FA levels in the gross anatomy dissection room.

  10. Carbon and oxygen isotope ratios of ecosystem respiration along an Oregon conifer transect: preliminary observations based on small-flask sampling.

    PubMed

    Ehleringer, J. R.; Cook, C. S.

    1998-01-01

    Isotope ratio analyses of atmospheric CO(2) at natural abundance have significant potential for contributing to our understanding of photosynthetic and respiration processes in forest ecosystems. Recent advances in isotope ratio mass spectrometry allow for rapid, on-line analysis of small volumes of CO(2) in air, and open new research opportunities at the ecophysiological, whole-organism, and atmospheric levels. Among the immediate applications are the carbon and oxygen isotope ratio analyses of carbon dioxide in atmospheric air. Routine analysis of carbon dioxide in air volumes of approximately 50-300 &mgr;l is accomplished by linking a commercially available, trace gas condenser and gas chromatograph to an isotope ratio mass spectrometer operated in continuous-flow mode. Samples collected in the field are stored in either gas-tight syringes or 100-ml flasks. The small sample volume required makes it possible to subsample the air in flasks for CO(2) and then to sample the remaining air volume for the analysis of the isotopic composition of either methane or nitrous oxide. Reliable delta(13)C and delta(18)O values can be obtained from samples collected and stored for 1-3 days. Longer-term storage, on the order of weeks, is possible for delta(13)C measurements without drift in the isotope ratio signal, and should also be possible for delta(18)O measurements. When linked with an infrared gas analyzer, pump and flask sampling system, it is feasible to sample CO(2) extensively in remote forest locations. The air-sampling system was used to measure the isotope ratios of atmospheric CO(2) and to conduct a regression analysis of the relationship between these two parameters. From the regression, we calculated the delta(13)C of ecosystem respiration of four coniferous ecosystems along a precipitation gradient in central Oregon. The ecosystems along the coast-to-interior Oregon (OTTER) gradient are dominated by spruce-hemlock forests at the wet, coastal sites (> 200 cm precipitation annually) to juniper woodlands (20 cm precipitation) at the interior, dry end of the transect. The delta(13)C values of ecosystem respiration along this transect differed by only 1.3 per thousand (range of -25.2 to -23.9 per thousand ) during August at the peak of the summer drought. Following autumn rains in September, the delta(13)C of ecosystem respiration in the four stands decreased; overall the difference in the carbon isotope ratio of ecosystem respiration among sites increased to 3.9 per thousand (-26.8 to -22.9 per thousand ).

  11. Personal exposure to JP-8 jet fuel vapors and exhaust at air force bases.

    PubMed

    Pleil, J D; Smith, L B; Zelnick, S D

    2000-03-01

    JP-8 jet fuel (similar to commercial/international jet A-1 fuel) is the standard military fuel for all types of vehicles, including the U.S. Air Force aircraft inventory. As such, JP-8 presents the most common chemical exposure in the Air Force, particularly for flight and ground crew personnel during preflight operations and for maintenance personnel performing routine tasks. Personal exposure at an Air Force base occurs through occupational exposure for personnel involved with fuel and aircraft handling and/or through incidental exposure, primarily through inhalation of ambient fuel vapors. Because JP-8 is less volatile than its predecessor fuel (JP-4), contact with liquid fuel on skin and clothing may result in prolonged exposure. The slowly evaporating JP-8 fuel tends to linger on exposed personnel during their interaction with their previously unexposed colleagues. To begin to assess the relative exposures, we made ambient air measurements and used recently developed methods for collecting exhaled breath in special containers. We then analyzed for certain volatile marker compounds for JP-8, as well as for some aromatic hydrocarbons (especially benzene) that are related to long-term health risks. Ambient samples were collected by using compact, battery-operated, personal whole-air samplers that have recently been developed as commercial products; breath samples were collected using our single-breath canister method that uses 1-L canisters fitted with valves and small disposable breathing tubes. We collected breath samples from various groups of Air Force personnel and found a demonstrable JP-8 exposure for all subjects, ranging from slight elevations as compared to a control cohort to > 100 [mutilpe] the control values. This work suggests that further studies should be performed on specific issues to obtain pertinent exposure data. The data can be applied to assessments of health outcomes and to recommendations for changes in the use of personal protective equipment that optimize risk reduction without undue impact on a mission.

  12. An international marine-atmospheric {sup 222}Rn measurement intercomparison in Bermuda. Part 1: NIST calibration and methodology for standardized sample additions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colle, R.; Unterweger, M.P.; Hodge, P.A.

    1996-01-01

    As part of an international {sup 222}Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (blind) {sup 222}Rn concentrations that could be related to US national standards. The standardized sample additions were obtained with a calibrated {sup 226}Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized {sup 222}Rn activity concentrations for the intercomparisonmore » ranged from approximately 2.5 Bq {center_dot} m{sup {minus}3} to 35 Bq {center_dot} m{sup {minus}3} (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6% to 13%. This paper describes the calibration and methodology for the standardized sample additions.« less

  13. An International Marine-Atmospheric 222Rn Measurement Intercomparison in Bermuda Part I: NIST Calibration and Methodology for Standardized Sample Additions

    PubMed Central

    Collé, R.; Unterweger, M. P.; Hodge, P. A.; Hutchinson, J. M. R.

    1996-01-01

    As part of an international 222Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (“blind”) 222Rn concentrations that could be related to U.S. national standards. The standardized sample additions were obtained with a calibrated 226Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized 222Rn activity concentrations for the intercomparison ranged from approximately 2.5 Bq · m−3 to 35 Bq · m−3 (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6 % to 13 %. This paper describes the calibration and methodology for the standardized sample additions. PMID:27805090

  14. Validation of the Asthma Illness Representation Scale-Spanish (AIRS-S).

    PubMed

    Sidora-Arcoleo, Kimberly Joan; Feldman, Jonathan; Serebrisky, Denise; Spray, Amanda

    2010-05-01

    To expand knowledge surrounding parental illness representations (IRs) of their children's asthma, it is imperative that culturally appropriate survey instruments are developed and validated for use in clinical and research settings. The Asthma Illness Representation Scale (AIRS) provides a structured assessment of the key components of asthma IRs, allowing the health care provider (HCP) to quickly identify areas of discordance with the professional model of asthma management. The English AIRS was developed and validated among a geographically and ethnically diverse sample. The authors present the validation results of the AIRS-S (Spanish) from a sample of Mexican and Puerto Rican parents. The AIRS was translated and back translated per approved methodologies. Factor analysis, internal reliability, external validity, and 2-week test-retest reliability (on a subsample) were carried out and results compared with the validated English version. Data were obtained from 80 Spanish-speaking Mexican and Puerto Rican parents of children with asthma. The sample was recruited from two school-based health centers and a free medical clinic in Phoenix, Arizona, and a hospital-based asthma clinic in Bronx, New York. The original Nature of Asthma Symptoms, Facts About Asthma, and Attitudes Towards Medication Use subscales emerged. Remaining factors were a mixture of items with no coherent or theoretical distinction between them. Interpretation of results is limited due to not meeting the minimum requirement of 5 observations/item. Cronbach's alpha coefficients for the total score (alpha = .77) and majority of subscales (alpha range = .53-.77) were acceptable and consistent with the English version. Parental reports of a positive relationship with the HCP significantly predicted AIRS scores congruent with the professional model; longer asthma duration was associated with beliefs aligned with the lay model; and AIRS scores congruent with the professional model were related to lower asthma severity. Stability in AIRS-S scores over 2 weeks was demonstrated. The AIRS-S is a culturally appropriate instrument that can be used by HCPs to ascertain Spanish-speaking parents' asthma illness beliefs and assess discordance with the professional model of asthma management. This information can be used by the HCP when discussing parent's asthma management strategies for their children during clinical encounters.

  15. Concepts and data-collection techniques used in a study of the unsaturated zone at a low-level radioactive-waste disposal site near Sheffield, Illinois

    USGS Publications Warehouse

    Healy, R.W.; DeVries, M.P.; Striegl, Robert G.

    1986-01-01

    A study of water and radionuclide movement through the unsaturated zone is being conducted at the low level radioactive waste disposal site near Sheffield, Illinois. Included in the study are detailed investigations of evapotranspiration, movement of water through waste trench covers, and movement of water and radionuclides (dissolved and gaseous) from the trenches. An energy balance/Bowen ratio approach is used to determine evapotranspiration. Precipitation, net radiation, soil-heat flux, air temperature and water vapor content gradients, wind speed, and wind direction are measured. Soil water tension is measured with tensiometers which are connected to pressure transducers. Meteorological sensors and tensiometers which are connected to pressure transducers. Meteorological sensors and tensiometers are monitored with automatic data loggers. Soil moisture contents are measured through small-diameter access tubes with neutron and gamma-ray attenuation gages. Data beneath the trenches are obtained through a 130-meter-long tunnel which extends under four of the trenches. Water samples are obtained with suction lysimeters, and samples of the geologic material are obtained with core tubes. These samples are analyzed for radiometric and inorganic chemistry. Gas samples are obtained from gas piezometers and analyzed for partial pressures of major constituents, Radon-222, tritiated water vapor, and carbon-14 dioxide. (USGS)

  16. Air pollution and DNA methylation alterations in lung cancer: A systematic and comparative study.

    PubMed

    Jiang, Cheng-Lan; He, Shui-Wang; Zhang, Yun-Dong; Duan, He-Xian; Huang, Tao; Huang, Yun-Chao; Li, Gao-Feng; Wang, Ping; Ma, Li-Ju; Zhou, Guang-Biao; Cao, Yi

    2017-01-03

    The lung cancer incidence in the Xuanwei and neighboring region, Yunnan, China, is among the highest in China and is attributed to severe air pollution with high benzo(a)pyrene levels. We systematically and comparatively analyzed DNA methylation alterations at genome and gene levels in Xuanwei lung cancer tissues and cell lines, as well as benzo(a)pyrene-treated cells and mouse samples. We obtained a comprehensive dataset of genome-wide cytosine-phosphate-guanine island methylation in air pollution-related lung cancer samples. Benzo(a)pyrene exposure induced multiple alterations in DNA methylation and in mRNA expressions of DNA methyltransferases and ten-11 translocation proteins; these alterations partially occurred in Xuanwei lung cancer. Furthermore, benzo(a)pyrene-induced DKK2 and EN1 promoter hypermethylation and LPAR2 promoter hypomethylation led to down-regulation and up-regulation of the genes, respectively; the down-regulation of DKK2 and EN1 promoted the cellular proliferation. Thus, DNA methylation alterations induced by benzo(a)pyrene contribute partially to abnormal DNA methylation in air pollution-related lung cancer, and these DNA methylation alterations may affect the development and progression of lung cancer. Additionally, vitamin C and B6 can reduce benzo(a)pyrene-induced DNA methylation alterations and may be used as chemopreventive agents for air pollution-related lung cancer.

  17. Method for Measuring Thermal Conductivity of Small Samples Having Very Low Thermal Conductivity

    NASA Technical Reports Server (NTRS)

    Miller, Robert A.; Kuczmarski, Maria a.

    2009-01-01

    This paper describes the development of a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air. As with other approaches, care is taken to ensure that the heat flow through the test sample is essentially one-dimensional. However, unlike other approaches, no attempt is made to use heated guards to block the flow of heat from the hot plate to the surroundings. It is argued that since large correction factors must be applied to account for guard imperfections when sample dimensions are small, it may be preferable to simply measure and correct for the heat that flows from the heater disc to directions other than into the sample. Experimental measurements taken in a prototype apparatus, combined with extensive computational modeling of the heat transfer in the apparatus, show that sufficiently accurate measurements can be obtained to allow determination of the thermal conductivity of low thermal conductivity materials. Suggestions are made for further improvements in the method based on results from regression analyses of the generated data.

  18. Analysis of radon and thoron progeny measurements based on air filtration.

    PubMed

    Stajic, J M; Nikezic, D

    2015-02-01

    Measuring of radon and thoron progeny concentrations in air, based on air filtration, was analysed in order to assess the reliability of the method. Changes of radon and thoron progeny activities on the filter during and after air sampling were investigated. Simulation experiments were performed involving realistic measuring parameters. The sensitivity of results (radon and thoron concentrations in air) to the variations of alpha counting in three and five intervals was studied. The concentration of (218)Po showed up to be the most sensitive to these changes, as was expected because of its short half-life. The well-known method for measuring of progeny concentrations based on air filtration is rather unreliable and obtaining unrealistic or incorrect results appears to be quite possible. A simple method for quick estimation of radon potential alpha energy concentration (PAEC), based on measurements of alpha activity in a saturation regime, was proposed. Thoron PAEC can be determined from the saturation activity on the filter, through beta or alpha measurements. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Air quality in passenger cars of the ground railway transit system in Beijing, China.

    PubMed

    Li, Tian-Tian; Bai, Yu-Hua; Liu, Zhao-Rong; Liu, Jin-Feng; Zhang, Guang-Shan; Li, Jin-Long

    2006-08-15

    This study examined the concentrations of carbon monoxide, carbon dioxide, TVOC, TSP, PM(10), PM(2.5), PM(1), benzene, toluene and xylene in passenger cars of the Beijing Ground Railway Transit System (Line No. 13). This system connects the northern suburb and downtown, and is equipped with air-conditioned passenger cars. In-train air quality monitoring was performed in both summer (July and August) and winter (December). To obtain representative data, the sampling design considered both rush and regular hours, urban and suburban areas, as well as the number of passengers. Meanwhile, questionnaires were distributed to the passengers. The monitoring results indicated that, overall, the air quality in the passenger cars was acceptable with a few exceptions, which is consistent with the passengers' perception. Concentrations of some air pollutants showed significant seasonal variations and had the significant difference between rush hour and regular hour. Furthermore, the in-train air quality was greatly influenced by the number of passengers. This paper describes the experimental design, and presents the preliminary results.

  20. A new set-up for simultaneous high-precision measurements of CO2, δ13C-CO2 and δ18O-CO2 on small ice core samples

    NASA Astrophysics Data System (ADS)

    Jenk, Theo Manuel; Rubino, Mauro; Etheridge, David; Ciobanu, Viorela Gabriela; Blunier, Thomas

    2016-08-01

    Palaeoatmospheric records of carbon dioxide and its stable carbon isotope composition (δ13C) obtained from polar ice cores provide important constraints on the natural variability of the carbon cycle. However, the measurements are both analytically challenging and time-consuming; thus only data exist from a limited number of sampling sites and time periods. Additional analytical resources with high analytical precision and throughput are thus desirable to extend the existing datasets. Moreover, consistent measurements derived by independent laboratories and a variety of analytical systems help to further increase confidence in the global CO2 palaeo-reconstructions. Here, we describe our new set-up for simultaneous measurements of atmospheric CO2 mixing ratios and atmospheric δ13C and δ18O-CO2 in air extracted from ice core samples. The centrepiece of the system is a newly designed needle cracker for the mechanical release of air entrapped in ice core samples of 8-13 g operated at -45 °C. The small sample size allows for high resolution and replicate sampling schemes. In our method, CO2 is cryogenically and chromatographically separated from the bulk air and its isotopic composition subsequently determined by continuous flow isotope ratio mass spectrometry (IRMS). In combination with thermal conductivity measurement of the bulk air, the CO2 mixing ratio is calculated. The analytical precision determined from standard air sample measurements over ice is ±1.9 ppm for CO2 and ±0.09 ‰ for δ13C. In a laboratory intercomparison study with CSIRO (Aspendale, Australia), good agreement between CO2 and δ13C results is found for Law Dome ice core samples. Replicate analysis of these samples resulted in a pooled standard deviation of 2.0 ppm for CO2 and 0.11 ‰ for δ13C. These numbers are good, though they are rather conservative estimates of the overall analytical precision achieved for single ice sample measurements. Facilitated by the small sample requirement, replicate measurements are feasible, allowing the method precision to be improved potentially. Further, new analytical approaches are introduced for the accurate correction of the procedural blank and for a consistent detection of measurement outliers, which is based on δ18O-CO2 and the exchange of oxygen between CO2 and the surrounding ice (H2O).

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devi, V. Malathy; Benner, D. Chris; Gamache, Robert R.

    In this paper, we report experimental measurements of spectral line shape parameters (air-broadened width, shift, and line mixing coefficients) for several transitions in the ν 3 Q branch of methane in the 3000–3023 cm -1 region. 13 high-resolution, room temperature laboratory spectra of pure methane and air-broadened methane recorded with two different Fourier transform spectrometers are fitted. 12 of these spectra were acquired at 0.01 cm -1 resolution with the McMath-Pierce FTS at the National Solar Observatory on Kitt Peak, and one higher-resolution (~0.0011 cm-1) low pressure methane spectrum was obtained with the Bruker IFS-120HR FTS at the Pacific Northwestmore » National Laboratory, in Richland, Washington. All the spectra were obtained using high purity natural samples of CH 4 and lean mixtures of the same natural CH 4 in dry air. For the 12 spectra recorded at Kitt Peak, three different absorption cells (L= 5, 25 and 150 cm) were used while the methane spectrum at PNNL was obtained using a 19.95 cm long absorption cell. For the analysis, an interactive multispectrum nonlinear least squares fitting software was employed where all the 13 spectra were fitted simultaneously. An accurate and self-consistent set of line parameters were determined by constraining a few of those for severely blended transitions. Line mixing was measured for fourteen transition pairs for the CH 4-air collision system. Lastly, a constant speed dependence parameter, consistent with measured speed dependence values obtained in other methane bands, was applied to all the transitions included in the fitted region. The present measurements are compared to values reported in the literature.« less

  2. Tooth Surface Comparison after Air Polishing and Rubber Cup: A Scanning Electron Microscopy Study.

    PubMed

    Camboni, Sara; Donnet, Marcel

    2016-03-01

    To demonstrate, using microscopic observations, the difference between two well-known oral prophylaxis techniques: polishing paste and air polishing. The observations were performed on human enamel. Enamel samples were obtained from plaque-rich human teeth extracted for orthodontic or clinical purposes. In order to allow a reliable comparison between different applications, each enamel sample was divided into two parts: one underwent air-polishing, whereas polishing paste was applied to the other. AIR-FLOW® Master was selected together with AIR-FLOW® PLUS for the prophylaxis powder application. For the polishing-paste application, several different pastes where used, including Cleanic®, CCS®, Proxyt®, and SuperPolish. A comparative test control was also used by cleaning the enamel with sodium hypochlorite (6%). The enamel treated with AIR-FLOW PLUS showed a similar surface when compared to the control enamel; however, there was complete cleaning down to the tooth microstructure. On the other hand, use of the polishing paste resulted in an enamel surface that appeared abraded and flattened. Moreover, some of the natural irregular enamel surfaces demonstrated some filling in with debris. AIR-FLOW PLUS powder was able to more deeply clean without creating any damage to the enamel, making it suitable for regular cleaning treatments. The polishing pastes were found to abrade the enamel surface, to flatten it, and deposit debris into the microcavities. Both methods having different mechanical effects can therefore be considered as complementary, in that some patients experience a sense of "roughness" following a cleaning. A clinical recommendation for this experience would be to use the air polish first to clean the enamel surface, and follow with a little polishing paste to smooth the surface, if required.

  3. Storage of cell samples for ToF-SIMS experiments-How to maintain sample integrity.

    PubMed

    Schaepe, Kaija; Kokesch-Himmelreich, Julia; Rohnke, Marcus; Wagner, Alena-Svenja; Schaaf, Thimo; Henss, Anja; Wenisch, Sabine; Janek, Jürgen

    2016-06-25

    In order to obtain comparable and reproducible results from time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of biological cells, the influence of sample preparation and storage has to be carefully considered. It has been previously shown that the impact of the chosen preparation routine is crucial. In continuation of this work, the impact of storage needs to be addressed, as besides the fact that degradation will unavoidably take place, the effects of different storage procedures in combination with specific sample preparations remain largely unknown. Therefore, this work examines different wet (buffer, water, and alcohol) and dry (air-dried, freeze-dried, and critical-point-dried) storage procedures on human mesenchymal stem cell cultures. All cell samples were analyzed by ToF-SIMS immediately after preparation and after a storage period of 4 weeks. The obtained spectra were compared by principal component analysis with lipid- and amino acid-related signals known from the literature. In all dry storage procedures, notable degradation effects were observed, especially for lipid-, but also for amino acid-signal intensities. This leads to the conclusion that dried samples are to some extent easier to handle, yet the procedure is not the optimal storage solution. Degradation proceeds faster, which is possibly caused by oxidation reactions and cleaving enzymes that might still be active. Just as well, wet stored samples in alcohol struggle with decreased signal intensities from lipids and amino acids after storage. Compared to that, the wet stored samples in a buffered or pure aqueous environment revealed no degradation effects after 4 weeks. However, this storage bears a higher risk of fungi/bacterial contamination, as sterile conditions are typically not maintained. Thus, regular solution change is recommended for optimized storage conditions. Not directly exposing the samples to air, wet storage seems to minimize oxidation effects, and hence, buffer or water storage with regular renewal of the solution is recommended for short storage periods.

  4. Storage of cell samples for ToF-SIMS experiments—How to maintain sample integrity

    PubMed Central

    Schaepe, Kaija; Kokesch-Himmelreich, Julia; Rohnke, Marcus; Wagner, Alena-Svenja; Schaaf, Thimo; Henss, Anja; Wenisch, Sabine; Janek, Jürgen

    2016-01-01

    In order to obtain comparable and reproducible results from time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of biological cells, the influence of sample preparation and storage has to be carefully considered. It has been previously shown that the impact of the chosen preparation routine is crucial. In continuation of this work, the impact of storage needs to be addressed, as besides the fact that degradation will unavoidably take place, the effects of different storage procedures in combination with specific sample preparations remain largely unknown. Therefore, this work examines different wet (buffer, water, and alcohol) and dry (air-dried, freeze-dried, and critical-point-dried) storage procedures on human mesenchymal stem cell cultures. All cell samples were analyzed by ToF-SIMS immediately after preparation and after a storage period of 4 weeks. The obtained spectra were compared by principal component analysis with lipid- and amino acid-related signals known from the literature. In all dry storage procedures, notable degradation effects were observed, especially for lipid-, but also for amino acid-signal intensities. This leads to the conclusion that dried samples are to some extent easier to handle, yet the procedure is not the optimal storage solution. Degradation proceeds faster, which is possibly caused by oxidation reactions and cleaving enzymes that might still be active. Just as well, wet stored samples in alcohol struggle with decreased signal intensities from lipids and amino acids after storage. Compared to that, the wet stored samples in a buffered or pure aqueous environment revealed no degradation effects after 4 weeks. However, this storage bears a higher risk of fungi/bacterial contamination, as sterile conditions are typically not maintained. Thus, regular solution change is recommended for optimized storage conditions. Not directly exposing the samples to air, wet storage seems to minimize oxidation effects, and hence, buffer or water storage with regular renewal of the solution is recommended for short storage periods. PMID:26810048

  5. Adaptive Sampling for Urban Air Quality through Participatory Sensing

    PubMed Central

    Zeng, Yuanyuan; Xiang, Kai

    2017-01-01

    Air pollution is one of the major problems of the modern world. The popularization and powerful functions of smartphone applications enable people to participate in urban sensing to better know about the air problems surrounding them. Data sampling is one of the most important problems that affect the sensing performance. In this paper, we propose an Adaptive Sampling Scheme for Urban Air Quality (AS-air) through participatory sensing. Firstly, we propose to find the pattern rules of air quality according to the historical data contributed by participants based on Apriori algorithm. Based on it, we predict the on-line air quality and use it to accelerate the learning process to choose and adapt the sampling parameter based on Q-learning. The evaluation results show that AS-air provides an energy-efficient sampling strategy, which is adaptive toward the varied outside air environment with good sampling efficiency. PMID:29099766

  6. A ground-based method of assessing urban forest structure and ecosystem services

    Treesearch

    David J. Nowak; Daniel E. Crane; Jack C. Stevens; Robert E. Hoehn; Jeffrey T. Walton; Jerry Bond

    2008-01-01

    To properly manage urban forests, it is essential to have data on this important resource. An efficient means to obtain this information is to randomly sample urban areas. To help assess the urban forest structure (e.g., number of trees, species composition, tree sizes, health) and several functions (e.g., air pollution removal, carbon storage and sequestration), the...

  7. Indoor air quality in public buildings. Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheldon, L.; Zelon, H.; Sickles, J.

    Two separate but closely related studies of exposures to volatile organic compounds (VOCs) in buildings where people spend long periods of time were conducted. This report summarizes results obtained in six buildings: a new hospital, office and nursing home and another office, office/school, and nursing home. At each building sampling was performed at three indoor locations and a single outdoor location.

  8. Journal Article: Atmospheric Measurements of CDDs, CDFs ...

    EPA Pesticide Factsheets

    The U.S. EPA established a National Dioxin Air Monitoring Network (NDAMN) to determine background air concentrations of PCDDs, PCDFs, and cp-PCBs in rural and remote areas of the United States. Background is defined as average ambient air concentrations inferred from long-term and multi-year atmospheric measurements at the same locations using identical monitoring and analytical procedures. The rural sites were chosen in order to obtain air concentrations in areas where crops and livestock are grown, and that encompassed a range of geographic locations in terms of latitudinal and longitudinal positions. Remote sites were selected on the basis that they were relatively free of human habitation and >100 km away from human dioxin sources. The locations of sampling sites covered a wide range of climate conditions from tropical sub-humid to sub-Artic climates. The idea behind the sampling configuration was to provide reasonable geographic coverage of the United States limited only by budgetary constraints. Funding was sufficient for the establishment and maintenance of 34 NDAMN stations over a period of 6 years. Results were reported as the toxic equivalent (TEQ) of the mix of PCDDs/PCDFs (TEQ-DF) and the mix of coplanar PCBs (TEQ-PCB). At the studied rural sites the mean annual TEQ-DF for each of the NDAMN sampling years was 10.43, 11.39, 10.40, and 10.47 femtograms per cubic meter (fg/cu. m) for 1999, 2000, 2001, and 2002, respectively.There was no statistical

  9. Influence of meteorological parameters on air quality

    NASA Astrophysics Data System (ADS)

    Gioda, Adriana; Ventura, Luciana; Lima, Igor; Luna, Aderval

    2013-04-01

    The physical characterization representative of ambient air particle concentrations is becoming a topic of great interest for urban air quality monitoring and human exposure assessment. Human exposure to particulate matter of less than 2.5 µm in diameter (PM2.5) can result in a variety of adverse health impacts, including reduced lung function and premature mortality. Numerous studies have shown that fine airborne inhalable particulate matter particles (PM2.5) are more dangerous to human health than coarse particles, e.g. PM10. This study investigates meteorological parameter impacts on PM2.5 concentrations in the atmosphere of Rio de Janeiro, Brazil. Samples were collected during 24 h every six days using a high-volume sampler from six sites in the metropolitan area of Rio de Janeiro from January to December 2011. The particles mass was determined by Gravimetry. Meteorological parameters were obtained from automatic stations near the sampling sites. The average PM2.5 concentrations ranged from 9 to 32 µg/m3 for all sites, exceeding the suggested annual limit of WHO (10 µg/m3). The relationship between the effects of temperature, relative humidity, wind speed and direction and particle concentration was examined using a Principal Component Analysis (PCA) for the different sites and seasons. The results for each sampling point and season presented different principal component numbers, varying from 2 to 4, and extremely different relationships with the parameters. This clearly shows that changes in meteorological conditions exert a marked influence on air quality.

  10. Laser-based measurements of δ13 C and δ2 H methane isotope signatures: precisions competitive with mass spectrometry methods

    NASA Astrophysics Data System (ADS)

    Yacovitch, Tara; Shorter, Joanne; Nelson, David; Herndon, Scott; Agnese, Mike; McManus, Barry; Zahniser, Mark

    2017-04-01

    In order to understand how and why methane (CH4 ) concentrations change over time, it is necessary to understand their sources and sinks. Stable isotope measurements of 13 CH4 :12 CH4 and CH3 D:12 CH4 ratios constrain the inventory of these sinks and sources. Current measurements often depend on Isotope Ratio Mass Spectrometry (IRMS), which requires extensive sample preparation including cryogenic separation of methane from air and subsequent conversion to either CO2 or H2 . Here, we detail improvements to a direct-absorption laser spectrometer that enable fast and precise measurements of methane isotope ratios (δ13 C and δ2 H ) of ambient air samples, without such sample preparation. The measurement system consists of a laser-based direct absorption spectrometer configured with a sample manifold for measurement of discrete samples (as opposed to flow-through measurements). Samples are trapped in the instrument using a rapid sample switching technique that compares each flask sample against a monitor tank sample. This approach reduces instrument drift and results in excellent precision. Precisions of 0.054 o/oo for δ13 C and 1.4 o/oo for δ2 H have been achieved (Allan-Werle deviations). These results are obtained in 20 minutes using 4 replicate comparisons to a monitor tank.

  11. Preliminary study of the acid deposition in the Tijuana Area (Mexico)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bravo, H.; Sosa, R.; Torres, R.

    1988-01-01

    Transboundary air pollution is of widespread international concern. Tijuana, Mexico, and San Diego, California, form one of the fastest growing border communities in the world. Projections place the current population of three million residents at nearly five million by the year 2000. Although the two cities are divided by an international border they share a common air base. Tijuana and southern portions of San Diego County are particularly affected by the exchange of air flow through the Tijuana River Canyon. The development of an air pollution acid rain monitoring and sampling program across the border, particularly in Tijuana is imperativemore » because of a planned new Tijuana industrial city, large numbers of existing industries without adequate emission controls, and thousands of vehicles generated pollutants on both sides of the border. The first steps toward an acid rain study along the mexican border began in 1985, with a project between the National Council of Science and Technology - (CONACYT) and the Center of the Atmospheric Sciences of the University of Mexico (CCA, UNAM). The goal of this project is to obtain acid rain data from five sites along the border. One of these sites is Tijuana, B.C., Mexico. The data obtained are reported in the paper.« less

  12. Visible and Near-IR Reflectance Spectra for Smectite, Sulfate And Perchlorate under Dry Conditions for Interpretation of Martian Surface Mineralogy

    NASA Technical Reports Server (NTRS)

    Morris, R.V.; Ming, W.; Golden, D.C.; Arvidson, R.E.; Wiseman, S.M.; Lichtenberg, K.A.; Cull, S.; Graff, T.G.

    2009-01-01

    Visible and near-IR (VNIR) spectral data for the martian surface obtained from orbit by the MRO-CRISM and OMEGA instruments are interpreted as having spectral signatures of H2O/OH-bearing phases, including smectites and other phyllosilicates, sulfates, and high-SiO2 phases [e.g., 1-4]. Interpretations of martian spectral signatures are based on and constrained by spectra that are obtained in the laboratory on samples with known mineralogical compositions and other physicochemical characteristics under, as appropriate, Mars-like environmental conditions (e.g., temperature, pressure, and humidity). With respect to environmental conditions, differences in the absolute concentration of atmospheric H2O can effect the hydration state and therefore the spectra signatures of smectite phyllosilicates (solvation H2O) and certain sulfates (hydration H2O) [e.g., 5-7]. We report VNIR spectral data acquired under humid (laboratory air) and dry (dry N2 gas) environments for two natural smectites (nontronite API-33A and saponite SapCa-1) to characterize the effect of solvation H2O on spectral properties. We also report spectral data for the thermal dehydration products of (1) melanterite (FeSO4.7H2O) in both air and dry N2 gas and (2) Mg-perchlorate (Mg(ClO4)2.6H2O) in dry N2 environments. Spectral measurements for samples dehydrated in dry N2 were made without exposing them to humid laboratory air.

  13. Non-proximate mass spectrometry using a heated 1-m long PTFE tube and an air-tight APCI ion source.

    PubMed

    Usmanov, Dilshadbek T; Hiraoka, Kenzo; Wada, Hiroshi; Matsumura, Masaya; Sanada-Morimura, Sachiyo; Nonami, Hiroshi; Yamabe, Shinichi

    2017-06-22

    Direct and rapid trace-level gas analysis is highly needed in various fields such as safety and security, quality control, food analysis, and forensic medicine. In many cases, the real samples are bulky and are not accessible to the space-limited ion source of the mass spectrometer. In order to circumvent this problem, we developed an airtight atmospheric-pressure chemical ionization (APCI) ion source equipped with a flexible 1-m-long, 2-mm-i.d. PTFE sniffing tube. The ambient air bearing sample gas was sucked into the heated PTFE tube (130 °C) and was transported to the air-tight ion source without using any extra pumping system or a Venturi device. Analytes were ionized by an ac corona discharge located at 1.5 mm from the inlet of the mass spectrometer. By using the airtight ion source, all the ionized gas in the ion source was introduced into the vacuum of the mass spectrometer via only the evacuation of the mass spectrometer (1.6 l min -1 ). Sub-pg limits of detection were obtained for carbaryl and trinitrotoluene. Owing to its flexibility and high sensitivity, the sniffing tube coupled with a mass spectrometer can be used as the stethoscope for the high-sensitive gas analysis. The experimental results obtained for drugs, hydrogen peroxide and small alkanes were discussed by DFT calculations. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Quantification and characterization of volatiles evolved during extrusion of rice and soy flours.

    PubMed

    Vodovotz, Y; Zasypkin, D; Lertsiriyothin, W; Lee, T C; Bourland, C T

    2000-01-01

    NASA-Johnson Space Center is designing and building a habitat (Bioregenerative Planetary Life Support Systems Test Complex, BIO-Plex) intended for evaluating advanced life support systems developed for long-duration missions to the Moon or Mars where all consumables will be recycled and reused. A food system based on raw products obtained from higher plants (such as soybeans, rice, and wheat) may be a central feature of a biologically based Advanced Life Support System. To convert raw crops to edible ingredients or food items, multipurpose processing equipment such as an extruder is ideal. Volatile compounds evolved during the manufacturing of these food products may accumulate and reach toxic levels. Additionally, off-odors often dissipated in open-air environments without consequence may cause significant discomfort in the BIO-Plex. Rice and defatted soy flours were adjusted to 16% moisture, and triplicate samples were extruded using a tabletop single-screw extruder. The extrudate was collected in specially designed Tedlar bags from which air samples could be extracted. The samples were analyzed by GC-MS with special emphasis on compounds with Spacecraft Maximum Allowable Concentrations (SMACs). Results showed a combination of alcohols, aldehydes, ketones, and carbonyl compounds in the different flours. Each compound and its SMAC value, as well as its impact on the air revitalization system, was discussed.

  15. Quantification and characterization of volatiles evolved during extrusion of rice and soy flours

    NASA Technical Reports Server (NTRS)

    Vodovotz, Y.; Zasypkin, D.; Lertsiriyothin, W.; Lee, T. C.; Bourland, C. T.

    2000-01-01

    NASA-Johnson Space Center is designing and building a habitat (Bioregenerative Planetary Life Support Systems Test Complex, BIO-Plex) intended for evaluating advanced life support systems developed for long-duration missions to the Moon or Mars where all consumables will be recycled and reused. A food system based on raw products obtained from higher plants (such as soybeans, rice, and wheat) may be a central feature of a biologically based Advanced Life Support System. To convert raw crops to edible ingredients or food items, multipurpose processing equipment such as an extruder is ideal. Volatile compounds evolved during the manufacturing of these food products may accumulate and reach toxic levels. Additionally, off-odors often dissipated in open-air environments without consequence may cause significant discomfort in the BIO-Plex. Rice and defatted soy flours were adjusted to 16% moisture, and triplicate samples were extruded using a tabletop single-screw extruder. The extrudate was collected in specially designed Tedlar bags from which air samples could be extracted. The samples were analyzed by GC-MS with special emphasis on compounds with Spacecraft Maximum Allowable Concentrations (SMACs). Results showed a combination of alcohols, aldehydes, ketones, and carbonyl compounds in the different flours. Each compound and its SMAC value, as well as its impact on the air revitalization system, was discussed.

  16. Environmental research program for slagging fixed-bed coal gasification. Status report, November 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilzbach, K. E.; Stetter, J. R.; Reilly, Jr., C. A.

    1982-02-01

    A collaborative environmental research program to provide information needed to assess the health and environmental effects associated with large-scale coal gasification technology is being conducted by Argonne National Laboratory (ANL) and the Grand Forks Energy Technology Center (GFETC). The objectives are to: investigate the toxicology and chemical composition of coal gasification by-products as a function of process variables and coal feed; compare the characteristics of isokinetic side-stream samples with those of process stream samples; identify the types of compounds responsible for toxicity; evaluate the chemical and toxicological effectiveness of various wastewater treatment operations; refine methodology for the collection and measurementmore » of organic vapors and particulates in workplace air; and obtain preliminary data on workplace air quality. So far the toxicities of a set of process stream samples (tar, oil, and gas liquor) and side-stream condensates from the GFETC gasifier have been measured in a battery of cellular screening tests for mutagenicity and cytotoxicity. Preliminary data on the effects of acute and chronic exposures of laboratory animals to process tar have been obtained. The process tar has been chemically fractionated and the distribution of mutagenicity and compound types among the fractions has been determined. Organic vapors and particulates collected at various times and locations in the gasifier building have been characterized.« less

  17. Mapping the human atria with optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Lye, Theresa H.; Gan, Yu; Hendon, Christine P.

    2017-02-01

    Atrial structure plays an important role in the mechanisms of atrial disease. However, detailed imaging of human atria remains limited due to many imaging modalities lacking sufficient resolution. We propose the use of optical coherence tomography (OCT), which has micrometer resolution and millimeter-scale imaging depth well-suited for the atria, combined with image stitching algorithms, to develop large, detailed atria image maps. Human atria samples (n = 7) were obtained under approved protocols from the National Disease Research Interchange (NDRI). One right atria sample was imaged using an ultrahigh-resolution spectral domain OCT system, with 5.52 and 2.72 μm lateral and axial resolution in air, respectively, and 1.78 mm imaging depth. Six left atria and five pulmonary vein samples were imaged using the spectral domain OCT system, Telesto I (Thorlabs GmbH, Germany) with 15 and 6.5 μm lateral and axial resolution in air, respectively, and 2.51 mm imaging depth. Overlapping image volumes were obtained from areas of the human left and right atria and the pulmonary veins. Regions of collagen, adipose, and myocardium could be identified within the OCT images. Image stitching was applied to generate fields of view with side dimensions up to about 3 cm. This study established steps towards mapping large regions of the human atria and pulmonary veins in high resolution using OCT.

  18. The environmental deposition of influenza virus from patients infected with influenza A(H1N1)pdm09: Implications for infection prevention and control.

    PubMed

    Killingley, Benjamin; Greatorex, Jane; Digard, Paul; Wise, Helen; Garcia, Fayna; Varsani, Harsha; Cauchemez, Simon; Enstone, Joanne E; Hayward, Andrew; Curran, Martin D; Read, Robert C; Lim, Wei S; Nicholson, Karl G; Nguyen-Van-Tam, Jonathan S

    2016-01-01

    In a multi-center, prospective, observational study over two influenza seasons, we sought to quantify and correlate the amount of virus recovered from the nares of infected subjects with that recovered from their immediate environment in community and hospital settings. We recorded the symptoms of adults and children with A(H1N1)pdm09 infection, took nasal swabs, and sampled touched surfaces and room air. Forty-two infected subjects were followed up. The mean duration of virus shedding was 6.2 days by PCR (Polymerase Chain Reaction) and 4.2 days by culture. Surface swabs were collected from 39 settings; 16 (41%) subject locations were contaminated with virus. Overall, 33 of the 671 (4.9%) surface swabs were PCR positive for influenza, of which two (0.3%) yielded viable virus. On illness Day 3, subjects yielding positive surface samples had significantly higher nasal viral loads (geometric mean ratio 25.7; 95% CI 1.75, 376.0, p=0.021) and a positive correlation (r=0.47, p=0.006) was observed between subject nasal viral loads and viral loads recovered from the surfaces around them. Room air was sampled in the vicinity of 12 subjects, and PCR positive samples were obtained for five (42%) samples. Influenza virus shed by infected subjects did not detectably contaminate the vast majority of surfaces sampled. We question the relative importance of the indirect contact transmission of influenza via surfaces, though our data support the existence of super-spreaders via this route. The air sampling results add to the accumulating evidence that supports the potential for droplet nuclei (aerosol) transmission of influenza. Copyright © 2015 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  19. Potential artifacts associated with historical preparation of joint compound samples and reported airborne asbestos concentrations.

    PubMed

    Brorby, G P; Sheehan, P J; Berman, D W; Bogen, K T; Holm, S E

    2011-05-01

    Airborne samples collected in the 1970s for drywall workers using asbestos-containing joint compounds were likely prepared and analyzed according to National Institute of Occupational Safety and Health Method P&CAM 239, the historical precursor to current Method 7400. Experimentation with a re-created, chrysotile-containing, carbonate-based joint compound suggested that analysis following sample preparation by the historical vs. current method produces different fiber counts, likely because of an interaction between the different clearing and mounting chemicals used and the carbonate-based joint compound matrix. Differences were also observed during analysis using Method 7402, depending on whether acetic acid/dimethylformamide or acetone was used during preparation to collapse the filter. Specifically, air samples of sanded chrysotile-containing joint compound prepared by the historical method yielded fiber counts significantly greater (average of 1.7-fold, 95% confidence interval: 1.5- to 2.0-fold) than those obtained by the current method. In addition, air samples prepared by Method 7402 using acetic acid/dimethylformamide yielded fiber counts that were greater (2.8-fold, 95% confidence interval: 2.5- to 3.2-fold) than those prepared by this method using acetone. These results indicated (1) there is an interaction between Method P&CAM 239 preparation chemicals and the carbonate-based joint compound matrix that reveals fibers that were previously bound in the matrix, and (2) the same appeared to be true for Method 7402 preparation chemicals acetic acid/dimethylformamide. This difference in fiber counts is the opposite of what has been reported historically for samples of relatively pure chrysotile dusts prepared using the same chemicals. This preparation artifact should be considered when interpreting historical air samples for drywall workers prepared by Method P&CAM 239. Copyright © 2011 JOEH, LLC

  20. International system of units traceable results of Hg mass concentration at saturation in air from a newly developed measurement procedure.

    PubMed

    Quétel, Christophe R; Zampella, Mariavittoria; Brown, Richard J C; Ent, Hugo; Horvat, Milena; Paredes, Eduardo; Tunc, Murat

    2014-08-05

    Data most commonly used at present to calibrate measurements of mercury vapor concentrations in air come from a relationship known as the "Dumarey equation". It uses a fitting relationship to experimental results obtained nearly 30 years ago. The way these results relate to the international system of units (SI) is not known. This has caused difficulties for the specification and enforcement of limit values for mercury concentrations in air and in emissions to air as part of national or international legislation. Furthermore, there is a significant discrepancy (around 7% at room temperature) between the Dumarey data and data calculated from results of mercury vapor pressure measurements in the presence of only liquid mercury. As an attempt to solve some of these problems, a new measurement procedure is described for SI traceable results of gaseous Hg concentrations at saturation in milliliter samples of air. The aim was to propose a scheme as immune as possible to analytical biases. It was based on isotope dilution (ID) in the liquid phase with the (202)Hg enriched certified reference material ERM-AE640 and measurements of the mercury isotope ratios in ID blends, subsequent to a cold vapor generation step, by inductively coupled plasma mass spectrometry. The process developed involved a combination of interconnected valves and syringes operated by computer controlled pumps and ensured continuity under closed circuit conditions from the air sampling stage onward. Quantitative trapping of the gaseous mercury in the liquid phase was achieved with 11.5 μM KMnO4 in 2% HNO3. Mass concentrations at saturation found from five measurements under room temperature conditions were significantly higher (5.8% on average) than data calculated from the Dumarey equation, but in agreement (-1.2% lower on average) with data based on mercury vapor pressure measurement results. Relative expanded combined uncertainties were estimated following a model based approach. They ranged from 2.2% to 2.8% (k = 2). The volume of air samples was traceable to the kilogram via weighing of water for the calibration of the sampling syringe. Procedural blanks represented on average less than 0.1% of the mass of Hg present in 7.4 cm(3) of air, and correcting for these blanks was not an important source of uncertainty.

  1. Residues of 2, 4-D in air samples from Saskatchewan: 1966-1975.

    PubMed

    Grover, R; Kerr, L A; Wallace, K; Yoshida, K; Maybank, J

    1976-01-01

    Residues of 2,4-D (2,4-dichlorophenoxyacetic acid) in air samples from several sampling sites in central and southern Saskatchewan during the spraying seasons in the 1966-68 and 1970-75 periods were determined by gas-liquid chromatographic techniques. Initially, individual esters of 2,4-D were characterized by retention times and confirmed further by co-injection and dual column procedures. Since 1973, however, only total 2,4-D acid levels in air samples have been determined after esterification to the methyl ester and confirmed by gc/ms techniques whenever possible. Up to 50% of the daily samples collected during the spraying season at any of the locations and during any given year contained 2,4-D, with butyl esters being found most frequently. The daily 24-hr mean atmospheric concentrations of 2,4-D ranged from 0.01 to 1.22 mug/m3, 0.01 to 13.50 mug/m3, and 0.05 to 0.59 mug/m3 for the iso-propyl, mixed butyl and iso-octyl esters, respectively. Even when the samples were analysed for the total 2,4-D content, i.e. from 1973 onwards, the maximum level of the total acid reached only 23.14 mug/m3. In any given year and at any of the sampling sites, about 30% of the samples contained less than 0.01 mug/m3 of 2,4-D. In another 40% of the samples, the levels of 2,4-D ranged from 0.01 to 0.099 mug/m3. Only about 30% of the samples contained 2,4-D concentrations higher than 0.1 mug/m3, with only 10% or less exceeding 1 mug/m3. None of the samples, obtained with the high volume particulate sampler, showed any detectable levels of 2,4-D, indicating little or no transport of 2,4-D adsorbed on dust particles or as crystals of amine salts.

  2. Prototype sampling system for measuring workplace protection factors for gases and vapors.

    PubMed

    Groves, William A; Reynolds, Stephen J

    2003-05-01

    A prototype sampling system for measuring respirator workplace protection factors (WPFs) was developed. Methods for measuring the concentration of contaminants inside respirators have previously been described; however, these studies have typically involved continuous sampling of aerosols. Our work focuses on developing an intermittent sampling system designed to measure the concentration of gases and vapors during inspiration. This approach addresses two potential problems associated with continuous sampling: biased results due to lower contaminant concentrations and high humidity in exhaled air. The system consists of a pressure transducer circuit designed to activate a pair of personal sampling pumps during inspiration based on differential pressure inside the respirator. One pump draws air from inside the respirator while the second samples the ambient air. Solid granular adsorbent tubes are used to trap the contaminants, making the approach applicable to a large number of gases and vapors. Laboratory testing was performed using a respirator mounted on a headform connected to a breathing machine producing a sinusoidal flow pattern with an average flow rate of 20 L/min and a period of 3 seconds. The sampling system was adjusted to activate the pumps when the pressure inside the respirator was less than -0.1 inch H(2)O. Quantitative fit-tests using human subjects were conducted to evaluate the effect of the sampling system on respirator performance. A total of 299 fit-tests were completed for two different types of respirators (half- and full-facepiece) from two different manufacturers (MSA and North). Statistical tests showed no significant differences between mean fit factors for respirators equipped with the sampling system versus unmodified respirators. Field testing of the prototype sampling system was performed in livestock production facilities and estimates of WPFs for ammonia were obtained. Results demonstrate the feasibility of this approach and will be used in developing improved instrumentation for measuring WPFs.

  3. EVALUATION OF GLOVEBOX GLOVES FOR EFFECTIVE PERMEATION CONTROL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korinko, P.

    A research and development task was undertaken to determine the permeabilities of hydrogen and dry air through different polymeric glove materials that are used to maintain the integrity of glovebox secondary containment. Fifteen different glove samples were obtained from four different manufacturers and samples cut from these gloves were tested. The gloves included baseline butyl rubber, Viton{reg_sign}, Dupont{reg_sign} Hypalon{reg_sign}, polyurethane, as well as composite gloves. The testing indicated that all of the vendor's butyl rubber gloves and the Jung Viton{reg_sign} gloves performed comparably in both gases.

  4. Eight Year Climatologies from Observational (AIRS) and Model (MERRA) Data

    NASA Technical Reports Server (NTRS)

    Hearty, Thomas; Savtchenko, Andrey; Won, Young-In; Theobalk, Mike; Vollmer, Bruce; Manning, Evan; Smith, Peter; Ostrenga, Dana; Leptoukh, Greg

    2010-01-01

    We examine climatologies derived from eight years of temperature, water vapor, cloud, and trace gas observations made by the Atmospheric Infrared Sounder (AIRS) instrument flying on the Aqua satellite and compare them to similar climatologies constructed with data from a global assimilation model, the Modern Era Retrospective-Analysis for Research and Applications (MERRA). We use the AIRS climatologies to examine anomalies and trends in the AIRS data record. Since sampling can be an issue for infrared satellites in low earth orbit, we also use the MERRA data to examine the AIRS sampling biases. By sampling the MERRA data at the AIRS space-time locations both with and without the AIRS quality control we estimate the sampling bias of the AIRS climatology and the atmospheric conditions where AIRS has a lower sampling rate. While the AIRS temperature and water vapor sampling biases are small at low latitudes, they can be more than a few degrees in temperature or 10 percent in water vapor at higher latitudes. The largest sampling biases are over desert. The AIRS and MERRA data are available from the Goddard Earth Sciences Data and Information Services Center (GES DISC). The AIRS climatologies we used are available for analysis with the GIOVANNI data exploration tool. (see, http://disc.gsfc.nasa.gov).

  5. Assessment of environmental impact on air quality by cement industry and mitigating measures: a case study.

    PubMed

    Kabir, G; Madugu, A I

    2010-01-01

    In this study, environmental impact on air quality was evaluated for a typical Cement Industry in Nigeria. The air pollutants in the atmosphere around the cement plant and neighbouring settlements were determined using appropriate sampling techniques. Atmospheric dust and CO2 were prevalent pollutants during the sampling period; their concentrations were recorded to be in the range of 249-3,745 mg/m3 and 2,440-2,600 mg/m3, respectively. Besides atmospheric dust and CO2, the air pollutants such as NOx, SOx and CO were in trace concentrations, below the safe limits approved by FEPA that are 0.0062-0.093 mg/m3 NOx, 0.026 mg/m3 SOx and 114.3 mg/m3 CO, respectively. Some cost-effective mitigating measures were recommended that include the utilisation of readily available and low-cost pozzolans material to produce blended cement, not only could energy efficiency be improved, but carbon dioxide emission could also be minimised during clinker production; and the installation of an advance high-pressure grinding rolls (clinker-roller-press process) to maximise energy efficiency to above what is obtainable from the traditional ball mills and to minimise CO2 emission from the power plant.

  6. New technique for calibrating hydrocarbon gas flowmeters

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Puster, R. L.

    1984-01-01

    A technique for measuring calibration correction factors for hydrocarbon mass flowmeters is described. It is based on the Nernst theorem for matching the partial pressure of oxygen in the combustion products of the test hydrocarbon, burned in oxygen-enriched air, with that in normal air. It is applied to a widely used type of commercial thermal mass flowmeter for a number of hydrocarbons. The calibration correction factors measured using this technique are in good agreement with the values obtained by other independent procedures. The technique is successfully applied to the measurement of differences as low as one percent of the effective hydrocarbon content of the natural gas test samples.

  7. Presence of lactic bacteria in the air of a winery during the vinification period.

    PubMed

    Garijo, P; López, R; Santamaría, P; Ocón, E; Olarte, C; Sanz, S; Gutiérrez, A R

    2009-11-30

    In this paper we have studied the presence and evolution in the winery air of the lactic bacteria responsible for malolactic fermentation. Sampling took place during the winemaking process (between September 2007 and July 2008) in a winery from the Rioja appellation in Spain. The results obtained indicated that the presence of these microorganisms in the atmosphere was detected when grapes were entering the winery, while malolactic fermentation was taking place, and when liquid containing bacteria was manipulated. The species and clones of the lactic bacteria identified were also related to those present in the vinification tanks at any given stage of the process.

  8. Air pollution source identification

    NASA Technical Reports Server (NTRS)

    Fordyce, J. S.

    1975-01-01

    Techniques for air pollution source identification are reviewed, and some results obtained with them are evaluated. Described techniques include remote sensing from satellites and aircraft, on-site monitoring, and the use of injected tracers and pollutants themselves as tracers. The use of a large number of trace elements in ambient airborne particulate matter as a practical means of identifying sources is discussed in detail. Sampling and analysis techniques are described, and it is shown that elemental constituents can be related to specific source types such as those found in the earth's crust and those associated with specific industries. Source identification sytems are noted which utilize charged particle X-ray fluorescence analysis of original field data.

  9. Efficiency of three different polishing methods on enamel and cementum: A scanning electron microscope study.

    PubMed

    Chowdhary, Zoya; Mohan, Ranjana

    2018-01-01

    Tooth polishing is an integral part of clinical dentistry. The main purpose of polishing is to smoothen the surface of the tooth and minimize the deposition of plaque to allow a healthy periodontal maintenance postscaling. Today, polishing by different methods is available to a clinician. Traditional bristle brush and rubber-cup polishing are being widely practiced and gradually getting replaced by novel air polisher. Pros and cons of each method should be weighed before its clinical applications. To evaluate and compare the efficiency of three different polishing systems on enamel as well as on cementum surfaces by scanning electron microscope (SEM). A total of 120 samples were divided into three groups randomly - Group 1 (bristle brush), Group 2 (rubber cup), and Group 3 (air polisher) - with 20 samples each of enamel and cementum, which were subdivided into 10 control and 10 test group (subjected to polishing). The samples were analyzed by SEM at ×1000 magnification, and the data obtained were compiled and subjected to statistical analysis. Polishing with bristle brush demonstrated less surface roughness and debris when compared to air polisher at P = 0.58, P = 0.03 for enamel surface and P = 0.003, P = 0.21 for cementum, respectively. The surface roughness was reduced considerably by rubber cup at P = 0.03 for enamel and P = 0.003 for cementum, compared to air polisher at P = 0.99 and P = 0.21 for enamel and cementum, respectively. The results indicate that polishing with rubber cup was more effective and statistically significant when compared to bristle brush polishing and air polisher for the crown and root surface smoothening and debris removal.

  10. Influence of Oxygen Adsorption on the Thermoelectric Power (tep) in Multiwalled Carbon Nanotubes

    NASA Astrophysics Data System (ADS)

    Savage, Traig; Bhattacharya, Sriparna; Sadanadan, Bindu; Gaillard, Jay; Tritt, Terry; Rao, Apparao; Sun, Ya-Ping

    2002-03-01

    The sign of the thermoelectric power (TEP) has been found to be extremely sensitive to oxygen adsorption in single walled carbon nanotube (SWNT) bundles [1-3]. A TEP value of ~ +54 μV/K has been reported in SWNT bundles that were exposed to room air, and upon desorbing the oxygen from the sample, the TEP switches reversibly to ~ -44 μV/K [2]. In this study we report TEP measurements in multiwalled carbon nanotubes (MWNTs) as functions of exposure time to room air (oxygen). The MWNTs were prepared on quartz substrates from a thermal decomposition of xylene-ferrocene mixtures at ~750^oC. Negative TEP values at all temperatures (10-300K) were obtained in freshly prepared MWNTs. Upon exposure of the MWNT film to room air and room light over a period of ~1 month, the TEP is found to change systematically to positive values. We also exposed another MWNT sample to ultraviolet (UV) radiation (λ=240 nm; ~1 W/m^2) in air for 10 days. The data indicates a photo-enhanced adsorption of oxygen as evidenced by a faster (factor of ~3) TEP sign reversal. The TEP in both the air- and UV-exposed films was shown to be completely reversible upon degassing the samples for ~12 hours. These findings are consistent with those reported in SWNT bundles, and a theoretical basis for the photo-induced oxygen adsorption will be presented. [1] P. G. Collins et al., Science, 287, 1804 (2000). [2] G. U. Sumanasekera et al., Phys. Rev. Lett., 85, 1096 (2000). [3] K. Bradley et al., Phys. Rev. Lett., 85, 4361 (2000).

  11. Evaluation of Stachybotrys chartarum in the house of an infant with pulmonary hemorrhage: quantitative assessment before, during, and after remediation.

    PubMed

    Vesper, S; Dearborn, D G; Yike, I; Allan, T; Sobolewski, J; Hinkley, S F; Jarvis, B B; Haugland, R A

    2000-03-01

    Stachybotrys chartarum is an indoor mold that has been associated with pulmonary hemorrhage cases in the Cleveland, Ohio, area. This study applied two new quantitative measurements to air samples from a home in which an infant developed PH. Quantitative polymerase chain reaction and a protein synthesis inhibition assay were used to determine the level of S. chartarum spores and their toxicity in air samples taken before, during, and after a remediation program was implemented to remove the fungus. Initial spore concentrations were between 0.1 and 9.3 spores/m3 of air, and the toxicity of air particulates was correspondingly low. However, the dust in the house contained between 0.4 and 2.1 x 10(3) spores/mg (as determined by hemocytometer counts). The remediation program removed all contaminated wallboard, paneling, and carpeting in the water-damaged areas of the home. In addition, a sodium hypochlorite solution was used to spray all surfaces during remediation. Although spore counts and toxicity were high during remediation, air samples taken postremediation showed no detectable levels of S. chartarum or related toxicity. Nine isolates of S. chartarum obtained from the home were analyzed for spore toxicity, hemolytic activity, and random amplified polymorphic DNA banding patterns. None of the isolates produced highly toxic spores (>90 microg T2 toxin equivalents per gram wet weight spores) after growth for 10 and 30 days on wet wallboard, but three isolates were hemolytic consistently. DNA banding patterns suggested that at least one of these isolates was related to isolates from homes of infants with previously investigated cases.

  12. Ambient air levels and health risk assessment of benzo(a)pyrene in atmospheric particulate matter samples from low-polluted areas: application of an optimized microwave extraction and HPLC-FL methodology.

    PubMed

    de la Gala Morales, María; Holgado, Fernando Rueda; Marín, Ma Rosario Palomo; Blázquez, Lorenzo Calvo; Gil, Eduardo Pinilla

    2015-04-01

    A new methodology involving a simple and fast pretreatment of the samples by microwave-assisted extraction and concentration by N2 stream, followed by HPLC with fluorescence detection, was used for determining the concentration of benzo(a)pyrene (BaP) in atmospheric particulate matter (PM10 fraction). Obtained LOD, 1.0 × 10(-3) ng/m(3), was adequate for the analysis of benzo(a)pyrene in the samples, and BaP recovery from PAH in Fine Dust (PM10-like) certified reference material was nearly quantitative (86%). The validated procedure was applied for analyzing 115 PM10 samples collected at different sampling locations in the low-polluted area of Extremadura (Southwest Spain) during a monitoring campaign carried out in 2011-2012. BaP spatial variations and seasonal variability were investigated as well as the influence of meteorological conditions and different air pollutants concentrations. A normalized protocol for health risk assessment was applied to estimate lifetime cancer risk due to BaP inhalation in the sampling areas, finding that around eight inhabitants per million people may develop lung cancer due to the exposition to BaP in atmospheric particulates emitted by the investigated sources.

  13. Diversity of indoor fungi as revealed by DNA metabarcoding.

    PubMed

    Korpelainen, Helena; Pietiläinen, Maria

    2017-01-01

    In the present study, we conducted DNA metabarcoding (the nuclear ITS2 region) for indoor fungal samples originating from two nursery schools with a suspected mould problem (sampling before and after renovation), from two university buildings, and from an old farmhouse. Good-quality sequences were obtained, and the results showed that DNA metabarcoding provides high resolution in fungal identification. The pooled proportions of sequences representing filamentous ascomycetes, filamentous basidiomycetes, yeasts, and other fungi equalled 62.3%, 8.0%, 28.3%, and 1.4%, respectively, and the total number of fungal genera found during the study was 585. When comparing fungal diversities and taxonomic composition between different types of buildings, no obvious pattern was detected. The average pairwise values of Sørensen Chao indices that were used to compare similarities for taxon composition between samples among the samples from the two university buildings, two nurseries, and farmhouse equaled 0.693, 0.736, 0.852, 0.928, and 0.981, respectively, while the mean similarity index for all samples was 0.864. We discovered that making explicit conclusions on the relationship between the indoor air quality and mycoflora is complicated by the lack of appropriate indicators for air quality and by the occurrence of wide spatial and temporal changes in diversity and compositions among samples.

  14. Terrestrial gamma radiation baseline mapping using ultra low density sampling methods.

    PubMed

    Kleinschmidt, R; Watson, D

    2016-01-01

    Baseline terrestrial gamma radiation maps are indispensable for providing basic reference information that may be used in assessing the impact of a radiation related incident, performing epidemiological studies, remediating land contaminated with radioactive materials, assessment of land use applications and resource prospectivity. For a large land mass, such as Queensland, Australia (over 1.7 million km(2)), it is prohibitively expensive and practically difficult to undertake detailed in-situ radiometric surveys of this scale. It is proposed that an existing, ultra-low density sampling program already undertaken for the purpose of a nationwide soil survey project be utilised to develop a baseline terrestrial gamma radiation map. Geoelement data derived from the National Geochemistry Survey of Australia (NGSA) was used to construct a baseline terrestrial gamma air kerma rate map, delineated by major drainage catchments, for Queensland. Three drainage catchments (sampled at the catchment outlet) spanning low, medium and high radioelement concentrations were selected for validation of the methodology using radiometric techniques including in-situ measurements and soil sampling for high resolution gamma spectrometry, and comparative non-radiometric analysis. A Queensland mean terrestrial air kerma rate, as calculated from the NGSA outlet sediment uranium, thorium and potassium concentrations, of 49 ± 69 nGy h(-1) (n = 311, 3σ 99% confidence level) is proposed as being suitable for use as a generic terrestrial air kerma rate background range. Validation results indicate that catchment outlet measurements are representative of the range of results obtained across the catchment and that the NGSA geoelement data is suitable for calculation and mapping of terrestrial air kerma rate. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  15. Occurrence of Infected Free-Living Amoebae in Cooling Towers of Southern Brazil.

    PubMed

    Soares, Scheila S; Souza, Thamires K; Berté, Francisco K; Cantarelli, Vlademir V; Rott, Marilise B

    2017-12-01

    This study determined the occurrence of potentially pathogenic free-living amoebae (FLA) and bacteria associated with amoebae in air-conditioning cooling towers in southern Brazil. Water samples were collected from 36 cooling systems from air-conditioning in the state of Rio Grande do Sul, Brazil. The organisms were identified using polymerase chain reaction (PCR) and sequencing automated. The results showed that these aquatic environments, with variable temperature, are potential "hot spots" for emerging human pathogens like free-living amoebae and bacteria associated. In total, 92% of the cooling-tower samples analyzed were positive for FLA, and Acanthamoeba was the dominant genus by culture and PCR. Amoebal isolates revealed intracellular bacteria in 39.3% of them and all were confirmed as members of the genus Pseudomonas. The results obtained show the important role of cooling towers as a source of amoebae-associated pathogens.

  16. Enhancement of acoustical performance of hollow tube sound absorber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Putra, Azma, E-mail: azma.putra@utem.edu.my; Khair, Fazlin Abd, E-mail: fazlinabdkhair@student.utem.edu.my; Nor, Mohd Jailani Mohd, E-mail: jai@utem.edu.my

    This paper presents acoustical performance of hollow structures utilizing the recycled lollipop sticks as acoustic absorbers. The hollow cross section of the structures is arranged facing the sound incidence. The effects of different length of the sticks and air gap on the acoustical performance are studied. The absorption coefficient was measured using impedance tube method. Here it is found that improvement on the sound absorption performance is achieved by introducing natural kapok fiber inserted into the void between the hollow structures. Results reveal that by inserting the kapok fibers, both the absorption bandwidth and the absorption coefficient increase. For testmore » sample backed by a rigid surface, best performance of sound absorption is obtained for fibers inserted at the front and back sides of the absorber. And for the case of test sample with air gap, this is achieved for fibers introduced only at the back side of the absorber.« less

  17. Enhancement of acoustical performance of hollow tube sound absorber

    NASA Astrophysics Data System (ADS)

    Putra, Azma; Khair, Fazlin Abd; Nor, Mohd Jailani Mohd

    2016-03-01

    This paper presents acoustical performance of hollow structures utilizing the recycled lollipop sticks as acoustic absorbers. The hollow cross section of the structures is arranged facing the sound incidence. The effects of different length of the sticks and air gap on the acoustical performance are studied. The absorption coefficient was measured using impedance tube method. Here it is found that improvement on the sound absorption performance is achieved by introducing natural kapok fiber inserted into the void between the hollow structures. Results reveal that by inserting the kapok fibers, both the absorption bandwidth and the absorption coefficient increase. For test sample backed by a rigid surface, best performance of sound absorption is obtained for fibers inserted at the front and back sides of the absorber. And for the case of test sample with air gap, this is achieved for fibers introduced only at the back side of the absorber.

  18. Urinary biomarkers of exposure to jet fuel (JP-8).

    PubMed Central

    Serdar, Berrin; Egeghy, Peter P; Waidyanatha, Suramya; Gibson, Roger; Rappaport, Stephen M

    2003-01-01

    Benzene, naphthalene, and 1- and 2-naphthol were measured in urine samples obtained from 322 U.S. Air Force personnel categorized a priori as likely to have low, moderate, or high exposure to jet fuel [jet propulsion fuel-8 (JP-8)]. In postexposure samples, levels of these analytes in the high-exposure group were 3- to 29-fold greater than in the low-exposure group and 2- to 12-fold greater than in the moderate-exposure group. Heavy exposure to JP-8 contributed roughly the same amount of benzene and more than three times the amount of naphthalene compared with cigarette smoking. Strong correlations were observed among postexposure levels of naphthalene-based biomarkers in urine and naphthalene in air and breath. We conclude that urinary naphthalene and the naphthols can serve as biomarkers of exposure to jet fuel. Of these, the naphthols are probably more useful because of their greater abundance and slower elimination kinetics. PMID:14594628

  19. Direct determination of total sulfur in wine using a continuum-source atomic-absorption spectrometer and an air-acetylene flame.

    PubMed

    Huang, Mao Dong; Becker-Ross, Helmut; Florek, Stefan; Heitmann, Uwe; Okruss, Michael

    2005-08-01

    Determination of sulfur in wine is an important analytical task, particularly with regard to food safety legislation, wine trade, and oenology. Hitherto existing methods for sulfur determination all have specific drawbacks, for example high cost and time consumption, poor precision or selectivity, or matrix effects. In this paper a new method, with low running costs, is introduced for direct, reliable, rapid, and accurate determination of the total sulfur content of wine samples. The method is based on measurement of the molecular absorption of carbon monosulfide (CS) in an ordinary air-acetylene flame by using a high-resolution continuum-source atomic-absorption spectrometer including a novel high-intensity short-arc xenon lamp. First results for total sulfur concentrations in different wine samples were compared with data from comparative ICP-MS measurements. Very good agreement within a few percent was obtained.

  20. Effect of variety on content of bioactive phenolic compounds in common elder (Sambucus nigra L.).

    PubMed

    Vrchotová, Naděžda; Dadáková, Eva; Matějíček, Aleš; Tříska, Jan; Kaplan, Jiří

    2017-03-01

    The inflorescence of common elder (Sambucus nigra L., Adoxaceae) is known to be rich in phenolic compounds. The content of five selected phenolic compounds (rutin, chlorogenic acid, isoquercitrin, isorhamnetin-3-O- rutinoside and dicaffeoylquinic acid) was determined in methanolic extracts from flowers and floral stems by HPLC in samples obtained from 20 varieties of S. nigra cultivated in Czech Republic. In all samples, there were determined rutin (11-54 mg/g), chlorogenic acid (23-46 mg/g), isoquercitrin (0.6-18 mg/g), isorhamnetin-3-O-rutinoside (3-10 mg/g), calculated on air-dried material. The content of dicaffeoylquinic acid was 0-13 mg/g of air-dried material. The amount of the analysed compounds in floral stems was lower than the flowers. The results are a unique set of information on the content of main phenolics in the inflorescence of cultured elderberry varieties.

  1. Aerosol chemistry in Beijing, China: Different pollution regimes and diurnal profiles

    NASA Astrophysics Data System (ADS)

    van Pinxteren, D.; Brüggemann, E.; Gnauk, T.; Iinuma, Y.; Müller, K.; Nowak, A.; Achtert, P.; Wiedensohler, A.; Herrmann, H.

    2009-04-01

    The rapid economic development during the last three decades in China has led to a severe decrease in air quality, especially in densely populated regions such as Beijing, Shanghai, and the Pearl River Delta. Although during last years a number of measures for air pollution control have been implemented especially in the capital Beijing, air pollution is still regarded to be one of the top environmental concerns in China during the next decade. To better characterize the processes leading to the frequently observed high concentrations of air pollutants on a regional scale, the international field campaign "Campaigns of Air Quality Research in Beijing 2006" (CAREBEIJING2006) was conducted in summer 2006. Organized by the Peking University, project partners from Japan, Korea, Hong Kong, Germany, and China studied the various aspects of gaseous and particulate air pollution in a megacity environment. In this contribution, we present chemical data of size-resolved particles, obtained by a 5-stage Berner impactor (0.05-10 μm) during 3 weeks at both an urban and a suburban site in the area of Beijing, China. The sampling time of the impactors was about 4-5 hours. This allowed for taking four size-resolved samples per day and obtaining rough diurnal profiles of particle components. The samples were analyzed for inorganic ions (Cl-, SO42-, NO3-, NH4+, K+, Ca2+, Na+, Mg2+), carbon sum parameters (OC, EC, WSOC), and a variety of organic compounds such as dicarboxylic acids, alkanes, PAHs and, for the first time in China, nitrooxy-organosulfates. On average, the observed PM10 mass concentrations were 133 μg m-3 and 112 μg m-3 at the urban and suburban site, respectively. In general, the observed concentrations of particulate pollutants were similarly high as reported from previous studies in the Beijing summer atmosphere. A back trajectory analysis allowed the classification of the samples into different meteorological categories with different air mass origins. A high influence of meteorology on the PM pollution was observed: The highest concentrations of both PM mass and particle constituents were measured when sampled air masses originated south of Beijing and moved over the area with low wind speeds. During such periods, a strong increase of daytime concentrations of the secondary ions sulfate, nitrate, ammonium, and also some dicarboxylic acids could be observed. The comparison of a suburban sampling site to an urban one revealed a clear influence of urban emissions on top of the regional pollution level for a period with relatively stagnant meteorological conditions and high photochemical processing. In contrast, during measurement periods with higher wind speeds and different air mass origins, the concentration levels of particulate pollutants were basically the same at the two sites. During an intensive period, a strong diurnal variation of particle sulfate concentration with increasing values from morning to afternoon was observed, which could be attributed to regional production. Similar observations where made for oxalic acid. Generally, water soluble organic carbon concentrations were enhanced by a factor of 2 in fine particles during the studied period of intense photochemistry. Elemental carbon, alkanes, and PAHs showed clear nighttime concentration maxima obviously due to enhanced emissions and a relatively low mixing volume during night. For the newly studied compound group of nitrooxy-organosulfates qualitative data can be presented indicating an influence of night-time chemistry and/or anthropogenic activities on their concentrations. The investigation of an intense nucleation and particle growth event revealed that the youngest particles largely consist of ammonium sulfate and primary carbonaceous material, with a possible contribution of secondary organic compounds.

  2. Assessment of airborne microorganism contamination in an industrial area characterized by an open composting facility and a wastewater treatment plant.

    PubMed

    Grisoli, Pietro; Rodolfi, Marinella; Villani, Simona; Grignani, Elena; Cottica, Danilo; Berri, Angelo; Picco, Anna Maria; Dacarro, Cesare

    2009-02-01

    In order to assess the potential exposure hazard to workers and people living in the immediate surroundings of an area characterized by an open composting facility and a wastewater treatment plant, a quantitative and a qualitative analysis of airborne microorganisms were carried out. Air sampling was performed once a week for four consecutive weeks in summer and winter. Six sites were selected as air sampling sites: one was upwind at approximately 40 m from the facilities; the other five were downwind at increasing distances from the facilities, with the furthest at 100 m away. Monitoring permitted us to verify the influence that the composting activities and wastewater treatment had on the bacterial and fungal contamination of the air. The results obtained have been expressed by means of contamination indexes that have already been used in previous works: a major microbiological contamination near the plants was evidenced. Near the facilities, mesophilic bacteria, psychrophilic bacteria and microfungi showed the highest median concentrations, respectively, of 307.5, 327.5 and 257.5 CFU/m(3). Moreover, the season generally influenced the concentration of the bacteria as well as of the fungi; higher in summer than in winter. The contamination index global index of microbial contamination (GIMC/m(3)) showed mean values of 4058.9 in summer and 439.7 in winter and the contamination index-amplification index (AI) showed values of 4.5 and 1.1 in the same seasons, respectively. Controlling the seasonal effect, mesophilic bacteria, Pseudomonas spp. and Enterobacteriaceae showed a significant decline in concentration with respect to upwind air samples and with increasing distance. Both GIMC and AI showed a significant decline with respect to upwind air samples by increasing the distance from facilities after adjusting for the seasonal effect. In conclusion, even if these plants do not represent a potential risk for nearby populations, they may pose a potential health risk for workers.

  3. Comparison of precipitation chemistry measurements obtained by the Canadian Air and Precipitation Monitoring Network and National Atmospheric Deposition Program for the period 1995-2004

    USGS Publications Warehouse

    Wetherbee, Gregory A.; Shaw, Michael J.; Latysh, Natalie E.; Lehmann, Christopher M.B.; Rothert, Jane E.

    2010-01-01

    Precipitation chemistry and depth measurements obtained by the Canadian Air and Precipitation Monitoring Network (CAPMoN) and the US National Atmospheric Deposition Program/National Trends Network (NADP/NTN) were compared for the 10-year period 1995–2004. Colocated sets of CAPMoN and NADP instrumentation, consisting of precipitation collectors and rain gages, were operated simultaneously per standard protocols for each network at Sutton, Ontario and Frelighsburg, Ontario, Canada and at State College, PA, USA. CAPMoN samples were collected daily, and NADP samples were collected weekly, and samples were analyzed exclusively by each network’s laboratory for pH, H + , Ca2+  , Mg2+  , Na + , K + , NH+4 , Cl − , NO−3 , and SO2−4 . Weekly and annual precipitation-weighted mean concentrations for each network were compared. This study is a follow-up to an earlier internetwork comparison for the period 1986–1993, published by Alain Sirois, Robert Vet, and Dennis Lamb in 2000. Median weekly internetwork differences for 1995–2004 data were the same to slightly lower than for data for the previous study period (1986–1993) for all analytes except NO−3 , SO2−4 , and sample depth. A 1994 NADP sampling protocol change and a 1998 change in the types of filters used to process NADP samples reversed the previously identified negative bias in NADP data for hydrogen-ion and sodium concentrations. Statistically significant biases (α = 0.10) for sodium and hydrogen-ion concentrations observed in the 1986–1993 data were not significant for 1995–2004. Weekly CAPMoN measurements generally are higher than weekly NADP measurements due to differences in sample filtration and field instrumentation, not sample evaporation, contamination, or analytical laboratory differences.

  4. Comparison of Remote Sensing and Fixed-Site Monitoring Approaches for Examining Air Pollution and Health in a National Study Population

    NASA Technical Reports Server (NTRS)

    Prud'homme, Genevieve; Dobbin, Nina A.; Sun, Liu; Burnet, Richard T.; Martin, Randall V.; Davidson, Andrew; Cakmak, Sabit; Villeneuve, Paul J.; Lamsal, Lok N.; vanDonkelaar, Aaron; hide

    2013-01-01

    Satellite remote sensing (RS) has emerged as a cutting edge approach for estimating ground level ambient air pollution. Previous studies have reported a high correlation between ground level PM2.5 and NO2 estimated by RS and measurements collected at regulatory monitoring sites. The current study examined associations between air pollution and adverse respiratory and allergic health outcomes using multi-year averages of NO2 and PM2.5 from RS and from regulatory monitoring. RS estimates were derived using satellite measurements from OMI, MODIS, and MISR instruments. Regulatory monitoring data were obtained from Canada's National Air Pollution Surveillance Network. Self-reported prevalence of doctor-diagnosed asthma, current asthma, allergies, and chronic bronchitis were obtained from the Canadian Community Health Survey (a national sample of individuals 12 years of age and older). Multi-year ambient pollutant averages were assigned to each study participant based on their six digit postal code at the time of health survey, and were used as a marker for long-term exposure to air pollution. RS derived estimates of NO2 and PM2.5 were associated with 6e10% increases in respiratory and allergic health outcomes per interquartile range (3.97 mg m3 for PM2.5 and 1.03 ppb for NO2) among adults (aged 20e64) in the national study population. Risk estimates for air pollution and respiratory/ allergic health outcomes based on RS were similar to risk estimates based on regulatory monitoring for areas where regulatory monitoring data were available (within 40 km of a regulatory monitoring station). RS derived estimates of air pollution were also associated with adverse health outcomes among participants residing outside the catchment area of the regulatory monitoring network (p < 0.05).

  5. Early-life exposure to air pollutants and adverse pregnancy outcomes: protocol for a prospective cohort study in Beijing

    PubMed Central

    Song, Jing; Wei, Ling; Ma, Ying; Tian, Ning; Huang, Shi Yun; Dai, Yin Mei; Zhao, Li Hong; Kong, Yuan Yuan

    2017-01-01

    Introduction The association between early exposure to ambient air pollution and adverse pregnancy outcomes in China is unclear. This study will assess the risk of early-life exposure to air pollutants in Beijing and explore the viability of 8-hydroxydeoxyguanosine (8-OHdG) as a biological indicator to assess oxidative stress induced by early-life exposure to air pollution. Methods and analysis Here, 2500 women with singleton pregnancies and their infants will be recruited from the Beijing Obstetrics and Gynecology Hospital. We will collect nine types of biological samples, including maternal serum, urine, placental tissue, umbilical cord tissue and umbilical cord blood during all three trimesters. The air pollution data (particulate matter (PM)2.5, PM10 and similar factors) will be recorded at official fixed-site monitoring stations closest to where the pregnant women live. We plan to assess the effect of air pollutants on adverse pregnancy outcomes and infant respiratory and circulatory disease using Cox regression and competitive risk analysis and explore possible critical windows of exposure during pregnancy using daily pollutant concentrations averaged over various periods of pregnancy combined with individual activity and physiological parameters. Maternal and umbilical cord blood samples (1000 samples) will be randomly selected for 8-OHdG assays to assess the correlation between exposures to air pollutants and oxidative stress. We will determine whether air pollutant exposure or 8-OHdG levels are associated with adverse pregnancy outcomes. SPSS and SAS statistical software will be used for data analysis. Cox regression and competing risk analysis will be used to compute the HR and population attributable risk. Ethics and dissemination This research protocol has already been approved by the Medical Ethics Committee of Beijing Obstetrics and Gynecology Hospital. Written informed consent will be obtained from all study participants prior to enrolment. The results will be published in peer-reviewed journals or disseminated through conference presentations. Trial registration number This study has been registered in WHO International Clinical Trial Register—Chinese Clinical Trial Registry under registration number ChiCTR-ROC-16010181 (http :// www.chictr.org.cn / showproj.aspx ?proj=17328). PMID:28871018

  6. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    PubMed

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Uncertainties in monitoring of SVOCs in air caused by within-sampler degradation during active and passive air sampling

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Přibylová, Petra; Vojta, Šimon; Kohoutek, Jiří; Lammel, Gerhard; Klánová, Jana

    2017-10-01

    Degradation of semivolatile organic compounds (SVOCs) occurs naturally in ambient air due to reactions with reactive trace gases (e.g., ozone, NOx). During air sampling there is also the possibility for degradation of SVOCs within the air sampler, leading to underestimates of ambient air concentrations. We investigated the possibility of this sampling artifact in commonly used active and passive air samplers for seven classes of SVOCs, including persistent organic pollutants (POPs) typically covered by air monitoring programs, as well as SVOCs of emerging concern. Two active air samplers were used, one equipped with an ozone denuder and one without, to compare relative differences in mass of collected compounds. Two sets of passive samplers were also deployed to determine the influence of degradation during longer deployment times in passive sampling. In active air samplers, comparison of the two sampling configurations suggested degradation of particle-bound polycyclic aromatic hydrocarbons (PAHs), with concentrations up to 2× higher in the denuder-equipped sampler, while halogenated POPs did not have clear evidence of degradation. In contrast, more polar, reactive compounds (e.g., organophosphate esters and current use pesticides) had evidence of losses in the sampler with denuder. This may be caused by the denuder itself, suggesting sampling bias for these compounds can be created when typical air sampling apparatuses are adapted to limit degradation. Passive air samplers recorded up to 4× higher concentrations when deployed for shorter consecutive sampling periods, suggesting that within-sampler degradation may also be relevant in passive air monitoring programs.

  8. PIXE analysis of Nigerian flour and bread samples

    NASA Astrophysics Data System (ADS)

    Olise, Felix S.; Fernandes, Adriana M.; Cristina Chaves, P.; Taborda, Ana; Reis, Miguel A.

    2014-01-01

    The alleged use of potassium bromate (KBrO3) in bread baking led a few authors to report on the chemical methods for the determination of KBrO3 levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about -16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples.

  9. Results from the Air Force Geophysics Laboratory survey catalog. [IR astronomy

    NASA Technical Reports Server (NTRS)

    Price, S. D.; Walker, R. G.

    1977-01-01

    Results of an IR survey program designed to obtain the spatial and brightness distributions of a representative sample of IR-emitting objects in the 3-30 micron range are analyzed. Small cryogenically cooled telescopes carried above the atmosphere on sounding rockets were employed in the research. Minimization of sky noise and photon background, experimental equipment, and data reduction techniques are discussed.

  10. Cryogenic separation of an oxygen-argon mixture in natural air samples for the determination of isotope and molecular ratios.

    PubMed

    Keedakkadan, Habeeb Rahman; Abe, Osamu

    2015-04-30

    The separation and purification of oxygen-argon mixtures are critical in the high-precision analysis of Δ(17) O and δ(O2 /Ar) for geochemical applications. At present, chromatographic methods are used for the separation and purification of oxygen-argon mixtures or pure oxygen, but these methods require the use of high-purity helium as a carrier gas. Considerable interest has been expressed in the development of a helium-free cryogenic separation of oxygen-argon mixtures in natural air samples. The precise and simplified cryogenic separation of oxygen-argon mixtures from natural air samples presented here was made possible using a single 5A (30/60 mesh) molecular sieve column. The method involves the trapping of eluted gases using molecular sieves at liquid nitrogen temperature, which is associated with isotopic fractionation. We tested the proposed method for the determination of isotopic fractionations during the gas exchange between water and atmospheric air at equilibrium. The dependency of fractionation was studied at different water temperatures and for different methods of equilibration (bubbling and stirring). Isotopic and molecular fractionations during gas desorption from molecular sieves were studied for different amounts and types of molecular sieves. Repeated measurements of atmospheric air yielded a reproducibility (±SD) of 0.021 ‰, 0.044 ‰, 15 per meg and 1.9 ‰ for δ(17) O, δ(18) O, Δ(17) O and δ(O2 /Ar) values, respectively. We applied the method to determine equilibrium isotope fractionation during gas exchange between air and water. Consistent δ(18) O and Δ(17) O results were obtained with the latest two studies, whereas there was a significant difference in δ(18) O values between seawater and deionized water. We have revised a helium-free, cryogenic separation of oxygen-argon mixtures in natural air samples for isotopic and molecular ratio analysis. The use of a single 13X (1/8" pellet) molecular sieve yielded the smallest isotopic and molecular fractionations, and this fractionation by molecular sieves can be corrected by the amount of molecular sieve used in the experiment. The reproducibility of the method was tested by the measurement of the oxygen isotope ratios of dissolved oxygen at equilibrium with atmospheric air. We confirmed that the choice of methods for making air-equilibrated water was not related to the magnitude of isotope fractionation, whereas there was a difference between seawater and deionized water. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Factors influencing microbial colonies in the air of operating rooms.

    PubMed

    Fu Shaw, Ling; Chen, Ian Horng; Chen, Chii Shya; Wu, Hui Hsin; Lai, Li Shing; Chen, Yin Yin; Wang, Fu Der

    2018-01-02

    The operating room (OR) of the hospital is a special unit that requires a relatively clean environment. The microbial concentration of an indoor OR extrinsically influences surgical site infection rates. The aim of this study was to use active sampling methods to assess microbial colony counts in working ORs and to determine the factors affecting air contamination in a tertiary referral medical center. This study was conducted in 28 operating rooms located in a 3000-bed medical center in northern Taiwan. The microbiologic air counts were measured using an impactor air sampler from May to August 2015. Information about the procedure-related operative characteristics and surgical environment (environmental- and personnel-related factors) characteristics was collected. A total of 250 air samples were collected during surgical procedures. The overall mean number of bacterial colonies in the ORs was 78 ± 47 cfu/m 3 . The mean number of colonies was the highest for transplant surgery (123 ± 60 cfu/m 3 ), followed by pediatric surgery (115 ± 30.3 cfu/m 3 ). A total of 25 samples (10%) contained pathogens; Coagulase-negative staphylococcus (n = 12, 4.8%) was the most common pathogen. After controlling for potentially confounding factors by a multiple regression analysis, the surgical stage had the significantly highest correlation with bacterial counts (r = 0.346, p < 0.001). Otherwise, independent factors influencing bacterial counts were the type of surgery (29.85 cfu/m 3 , 95% CI 1.28-58.42, p = 0.041), site of procedure (20.19 cfu/m 3 , 95% CI 8.24-32.14, p = 0.001), number of indoor staff (4.93 cfu/m 3 , 95% CI 1.47-8.38, p = 0.005), surgical staging (36.5 cfu/m 3 , 95% CI 24.76-48.25, p < 0.001), and indoor air temperature (9.4 cfu/m 3 , 95% CI 1.61-17.18, p = 0.018). Under the well-controlled ventilation system, the mean microbial colony counts obtained by active sampling in different working ORs were low. The number of personnel and their activities critically influence the microbe concentration in the air of the OR. We suggest that ORs doing complex surgeries with more surgical personnel present should increase the frequency of air exchanges. A well-controlled ventilation system and infection control procedures related to environmental and surgical procedures are of paramount importance for reducing microbial colonies in the air.

  12. Early and long-term mantle processing rates derived from xenon isotopes

    NASA Astrophysics Data System (ADS)

    Mukhopadhyay, S.; Parai, R.; Tucker, J.; Middleton, J. L.; Langmuir, C. H.

    2015-12-01

    Noble gases, particularly xenon (Xe), in mantle-derived basalts provide a rich portrait of mantle degassing and surface-interior volatile exchange. The combination of extinct and extant radioactive species in the I-Pu-U-Xe systems shed light on the degassing history of the early Earth throughout accretion, as well as the long-term degassing of the Earth's interior in association with plate tectonics. The ubiquitous presence of shallow-level air contamination, however, frequently obscures the mantle Xe signal. In a majority of the samples, shallow air contamination dominates the Xe budget. For example, in the gas-rich popping rock 2ΠD43, 129Xe/130Xe ratios reach 7.7±0.23 in individual step-crushes, but the bulk composition of the sample is close to air (129Xe/130Xe of 6.7). Thus, the extent of variability in mantle source Xe composition is not well-constrained. Here, we present new MORB Xe data and explore constraints placed on mantle processing rates by the Xe data. Ten step-crushes were obtained on a depleted popping glass that was sealed in ultrapure N2 after dredge retrieval from between the Kane-Atlantis Fracture Zone of the Mid Atlantic Ridge in May 2012. 9 steps yielded 129Xe/130Xe of 7.50-7.67 and one yielded 7.3. The bulk 129Xe/130Xe of the sample is 7.6, nearly identical to the estimated mantle source value of 7.7 for the sample. Hence, the sample is virtually free of shallow-level air contamination. Because sealing the sample in N2upon dredge retrieval largely eliminated air contamination, for many samples, contamination must be added after sample retrieval from the ocean bottom. Our new high-precision Xe isotopic measurements in upper mantle-derived samples provide improved constraints on the Xe isotopic composition of the mantle source. We developed a forward model of mantle volatile evolution to identify solutions that satisfy our Xe isotopic data. We find that accretion timescales of ~10±5 Myr are consistent with I-Pu-Xe constraints, and the last giant impact occurred 45-70 Myr after the start of the solar system. After the giant impact stage, the Pu-U-Xe system indicates that degassing of the planet via solid-state mantle convection and plate tectonics continued to liberate volatiles to the atmosphere and has led to between ~5-8 mantle turnovers over the age of the Earth.

  13. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    USGS Publications Warehouse

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  14. A pilot study of bioaerosol reduction using an air cleaning system during dental procedures.

    PubMed

    Hallier, C; Williams, D W; Potts, A J C; Lewis, M A O

    2010-10-23

    Bioaerosols are defined as airborne particles of liquid or volatile compounds that contain living organisms or have been released from living organisms. The creation of bioaerosols is a recognized consequence of certain types of dental treatment and represents a potential mechanism for the spread of infection. The aims of the present study were to assess the bioaerosols generated by certain dental procedures and to evaluate the efficiency of a commercially available Air Cleaning System (ACS) designed to reduce bioaerosol levels. Bioaerosol sampling was undertaken in the absence of clinical activity (baseline) and also during treatment procedures (cavity preparation using an air rotor, history and oral examination, ultrasonic scaling and tooth extraction under local anaesthesia). For each treatment, bioaerosols were measured for two patient episodes (with and without ACS operation) and between five and nine bioaerosol samples were collected. For baseline measurements, 15 bioaerosol samples were obtained. For bioaerosol sampling, environmental air was drawn on to blood agar plates using a bioaerosol sampling pump placed in a standard position 20 cm from the dental chair. Plates were incubated aerobically at 37°C for 48 hours and resulting growth quantified as colony forming units (cfu/m³). Distinct colony types were identified using standard methods. Results were analysed statistically using SPSS 12 and Wilcoxon signed rank tests. The ACS resulted in a significant reduction (p = 0.001) in the mean bioaerosols (cfu/m³) of all three clinics compared with baseline measurements. The mean level of bioaerosols recorded during the procedures, with or without the ACS activated respectively, was 23.9 cfu/m³ and 105.1 cfu/m³ (p = 0.02) for cavity preparation, 23.9 cfu/m³ and 62.2 cfu/m³ (p = 0.04) for history and oral examination; 41.9 cfu/m³ and 70.9 cfu/m³ (p = 0.01) for ultrasonic scaling and 9.1 cfu/m³ and 66.1 cfu/m³ (p = 0.01) for extraction. The predominant microorganisms isolated were Staphylococcus species and Micrococcus species. These findings indicate potentially hazardous bioaerosols created during dental procedures can be significantly reduced using an air cleaning system.

  15. Interaction of ozone with wooden building products, treated wood samples and exotic wood species

    NASA Astrophysics Data System (ADS)

    Schripp, Tobias; Langer, Sarka; Salthammer, Tunga

    2012-07-01

    Wooden building products indoors are known to be able to affect the perceived air quality depending on their emission strength. The indoor application of modern ecological lacquer systems (eco-lacquers or 'green' lacquers) may be a much stronger source than the substrates itself. Especially with regard to the formation of ultrafine particles by gas-to-particle conversion in the presence of ozone or other reactive species the impact of the applied building products on the indoor air quality has to be addressed. The present study reports a two concentration step ozonation of OSB panels, painted beech boards, and a number of solid 'exotic' wood types in a 1 m³ emission test chamber. The emission of volatile organic compounds (VOC) was recorded as well as the formation of ultrafine particles in the range 7-300 nm. The products are characterized on the basis of their ozone deposition velocity; the obtained values of 0.008-0.381 cm s-1 are comparable with previously published data. Within the samples of the present study one eco-lacquer was the strongest source of VOC (total VOC ˜ 60 mg m-3) while the wooden building products (OSB) were of intermediate emission strength. The lowest emission was found for the solid (exotic) wood samples. The VOC release of the samples corresponded roughly to the particle formation potential. However, the strongest UFP formation was measured for one solid wood sample ('Garapa') which showed a strong surface reaction in the presence of ozone and formed a large number of particles <40 nm. Overall, the experiments demonstrated the necessity of real-life samples for the estimation of UFP indoor air pollution from the ozone chemistry of terpenes.

  16. Detection of living cells in stratospheric samples

    NASA Astrophysics Data System (ADS)

    Harris, Melanie J.; Wickramasinghe, N. C.; Lloyd, David; Narlikar, J. V.; Rajaratnam, P.; Turner, Michael P.; Al-Mufti, Shirwan; Wallis, Max K.; Ramadurai, S.; Hoyle, Fred

    2002-02-01

    Air samples collected aseptically over tropical India at various stratospheric altitudes ranging from 20 to 41 km using cryosampler assemblies carried on balloons flown from Hyderabad have shown evidence of living microbial cells. Unambiguous evidence of living cells came from examining micropore filters on which the samples were recovered with the use of voltage sensitive lipophilic dyes that could detect the presents of active cells. Clumps of viable cells were found at all altitudes using this technique, and this conclusion was found to be consistent with images obtained from electron microscopy. Since the 41 km sample was collected well above the local tropopause, a prima facie case for a space incidence of these microorganisms is established. Further work on culturing, PCR analysis and isotopic analysis is in progress.

  17. Automated Smartphone Threshold Audiometry: Validity and Time Efficiency.

    PubMed

    van Tonder, Jessica; Swanepoel, De Wet; Mahomed-Asmail, Faheema; Myburgh, Hermanus; Eikelboom, Robert H

    2017-03-01

    Smartphone-based threshold audiometry with automated testing has the potential to provide affordable access to audiometry in underserved contexts. To validate the threshold version (hearTest) of the validated hearScreen™ smartphone-based application using inexpensive smartphones (Android operating system) and calibrated supra-aural headphones. A repeated measures within-participant study design was employed to compare air-conduction thresholds (0.5-8 kHz) obtained through automated smartphone audiometry to thresholds obtained through conventional audiometry. A total of 95 participants were included in the study. Of these, 30 were adults, who had known bilateral hearing losses of varying degrees (mean age = 59 yr, standard deviation [SD] = 21.8; 56.7% female), and 65 were adolescents (mean age = 16.5 yr, SD = 1.2; 70.8% female), of which 61 had normal hearing and the remaining 4 had mild hearing losses. Threshold comparisons were made between the two test procedures. The Wilcoxon signed-ranked test was used for comparison of threshold correspondence between manual and smartphone thresholds and the paired samples t test was used to compare test time. Within the adult sample, 94.4% of thresholds obtained through smartphone and conventional audiometry corresponded within 10 dB or less. There was no significant difference between smartphone (6.75-min average, SD = 1.5) and conventional audiometry test duration (6.65-min average, SD = 2.5). Within the adolescent sample, 84.7% of thresholds obtained at 0.5, 2, and 4 kHz with hearTest and conventional audiometry corresponded within ≤5 dB. At 1 kHz, 79.3% of the thresholds differed by ≤10 dB. There was a significant difference (p < 0.01) between smartphone (7.09 min, SD = 1.2) and conventional audiometry test duration (3.23 min, SD = 0.6). The hearTest application with calibrated supra-aural headphones provides a cost-effective option to determine valid air-conduction hearing thresholds. American Academy of Audiology

  18. Relationships between socioeconomic and lifestyle factors and indoor air quality in French dwellings.

    PubMed

    Brown, Terry; Dassonville, Claire; Derbez, Mickael; Ramalho, Olivier; Kirchner, Severine; Crump, Derrick; Mandin, Corinne

    2015-07-01

    To date, few studies have analyzed the relationships between socioeconomic status (SES) and indoor air quality (IAQ). The aim of this study was to examine the relationships between socioeconomic and other factors and indoor air pollutant levels in French homes. The indoor air concentrations of thirty chemical, biological and physical parameters were measured over one week in a sample of 567 dwellings representative of the French housing stock between September 2003 and December 2005. Information on SES (household structure, educational attainment, income, and occupation), building characteristics, and occupants' habits and activities (smoking, cooking, cleaning, etc.) were collected through administered questionnaires. Separate stepwise linear regression models were fitted to log-transformed concentrations on SES and other factors. Logistic regression was performed on fungal contamination data. Households with lower income were more likely to have higher indoor concentrations of formaldehyde, but lower perchloroethylene indoor concentrations. Formaldehyde indoor concentrations were also associated with newly built buildings. Smoking was associated with increasing acetaldehyde and PM2.5 levels and the risk of a positive fungal contamination index. BTEX levels were also associated with occupant density and having an attached garage. The major predictors for fungal contamination were dampness and absolute humidity. These results, obtained from a large sample of dwellings, show for the first time in France the relationships between SES factors and indoor air pollutants, and believe they should be considered alongside occupant activities and building characteristics when study IAQ in homes. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  19. Can we use modelling methodologies to assess airborne benzo[a]pyrene from biomonitors? A comprehensive evaluation approach

    NASA Astrophysics Data System (ADS)

    Ratola, N.; Jiménez-Guerrero, P.

    2015-09-01

    Biomonitoring data available on levels of atmospheric polycyclic aromatic hydrocarbons (PAHs) in pine needles from the Iberian Peninsula was used to estimate air concentrations of benzo[a]pyrene (BaP) and, at the same time, fuelled the comparison with chemistry transport model representations. Simulations with the modelling system WRF + CHIMERE were validated against data from the European Monitoring and Evaluation Programme (EMEP) air sampling network and using modelled atmospheric concentrations as a consistent reference in order to compare the performance of vegetation-to-air estimating methods. A spatial and temporal resolution of 9 km and 1 h was implemented. The field-based database relied on a pine needles sampling scheme comprising 33 sites in Portugal and 37 sites in Spain complemented with the BaP measurements available from the EMEP sites. The ability of pine needles to act as biomonitoring markers for the atmospheric concentrations of BaP was estimated converting the levels obtained in pine needles into air concentrations by six different approaches, one of them presenting realistic concentrations when compared to the modelled atmospheric values. The justification for this study is the gaps still existing in the knowledge of the life cycles of semi-volatile organic compounds (SVOCs), particularly the partition processes between air and vegetation. The strategy followed in this work allows the definition of the transport patterns (e.g. dispersion) established by the model for atmospheric concentrations and the estimated values in vegetation.

  20. Evaluation of Impacts of Landuse Changes on Air Quality in Hyderabad Metropolis Using Remote Sensing and GIS - A Case Study from Indian Sub-Continent

    NASA Astrophysics Data System (ADS)

    Vuppala, P.; S. S, A.; Mareddy, A.

    2004-12-01

    Around the world cities in developing countries are rapidly growing as more and more people become urban dwellers resulting in increased level of air pollution caused by changes in transportation, energy production and industrial activities. Air quality is an issue of critical importance in view of the accumulating evidence showing the adverse effects of pollution on human health, agricultural crops, manmade environments and ecosystems. An integrated study for identification of appropriate sites for representative evaluation of air pollution, novel means of monitoring air quality, identifying the predominant sources of pollution, effective assessment of air quality and evaluation of different management strategies essential for the development of a healthy and livable region is carried out for Hyderabad metropolis in India using Remote sensing and Geographical Information System (GIS) based assessment tools. Correlation studies between the concentration level of pollutants in urban air and urban land use are also dealt with. Municipal Corporation of Hyderabad (MCH) is divided into eleven planning zones out of which the present study area i.e. Zone I & IIA comprises of industrial, highly commercial and densely populated areas, apart from medium and sparse residential areas making it environmentally sensitive. Sampling locations were identified based on the land use/ land cover of the region and air samples were collected from areas having varying land use patterns using a high volume air sampler. The samples were then analyzed for the presence of Sulphur oxides(SO--x), Oxides of Nitrogen(NO--x), Total Suspended Particulate Matter(TSPM) and Respirable Suspended Particulate Matter(RSPM) using standard protocols and maps showing spatial distribution of SOx, NO--x, TSPM & RSPM were prepared using curve fitting technique of Arc/Info & ArcView GIS software. Air Quality Index (AQI), indicating the overall quality of air and extent of pollution is also calculated, based on which the entire study area is classified into severely, highly, moderately and lightly polluted areas. Concentration of SOx and NOx were observed to be within limits, while particulate pollutants exceeded the standards prescribed by Central Pollution Control Board (CPCB). The major cause of pollution in the study area is attributed to the increasing vehicular movements and presence of commercial and public related activities such as shopping malls. It is observed for the category of severe air pollution that 42% of pollution is from dense residential areas, 19% from medium residential and 1% load of pollution from other public related activities. Based on the results obtained suitable remedial measures to combat the increasing urban air pollution are suggested in the study area. Key words: Air pollution, Remote sensing, Geographical Information System, Spatial distribution, Air quality index.

  1. A method to estimate spatiotemporal air quality in an urban traffic corridor.

    PubMed

    Singh, Nongthombam Premananda; Gokhale, Sharad

    2015-12-15

    Air quality exposure assessment using personal exposure sampling or direct measurement of spatiotemporal air pollutant concentrations has difficulty and limitations. Most statistical methods used for estimating spatiotemporal air quality do not account for the source characteristics (e.g. emissions). In this study, a prediction method, based on the lognormal probability distribution of hourly-average-spatial concentrations of carbon monoxide (CO) obtained by a CALINE4 model, has been developed and validated in an urban traffic corridor. The data on CO concentrations were collected at three locations and traffic and meteorology within the urban traffic corridor.(1) The method has been developed with the data of one location and validated at other two locations. The method estimated the CO concentrations reasonably well (correlation coefficient, r≥0.96). Later, the method has been applied to estimate the probability of occurrence [P(C≥Cstd] of the spatial CO concentrations in the corridor. The results have been promising and, therefore, may be useful to quantifying spatiotemporal air quality within an urban area. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Polycyclic aromatic hydrocarbons in a bakery indoor air: trends, dynamics, and dispersion.

    PubMed

    Ielpo, Pierina; Taurino, Maria Rosaria; Buccolieri, Riccardo; Placentino, Claudia Marcella; Gallone, Francesco; Ancona, Valeria; Di Sabatino, Silvana

    2018-02-27

    Indoor air pollution assessment in work environments remains challenging due to a combination of logistic reasons and availability of costly instrumentation for data acquisition and post-processing. Existing literature focuses on energy production environments, hospitals, and less so on food production spaces. Studies on indoor air quality in bakeries are scarce or even absent. Motivated by this, the present study investigates indoor air quality in a bakery located in Bari province in South Italy, using a combination of approaches including analytical chemistry analyses and computational fluid dynamics to reconstruct the air ventilation in response to air temperature gradients within the working environment. PM 2.5 indoor samplings were collected every 6 h from 7 to 19 April 2013 in the proximity of two bakery ovens powered by gas and wood, respectively. For each sampling day, 4 PM 2.5 samples were collected: from 3:00 to 9:00 h (first), from 9:00 to 13:30 h (second), from 14:00 to 21:00 h (third), and from 21:00 to 3:00 h (fourth). In total, 40 samples were collected. On each sample, several polycyclic aromatic hydrocarbons (PAHs) were determined such as benzo[a]anthracene (228), benzo[b]fluoranthene (252), benzo[k]fluoranthene (252), benzo[a]pyrene (252), benzo[g,h,i]perylene (276), indeno[1,2,3-cd]pyrene (276), and dibenzo[a,h]anthracene (278), the main compounds of 16 priority US Environmental Protection Agency (US-EPA) PAHs in particulate phase. The PAH mean concentrations showed higher values during the first (from 3:00 to 9:00 h) and fourth (from 21:00 to 3:00 h) sampling intervals than the other two with benzo[a]pyrene mean values exceeding the Italian law limit of 1 ng/m 3 . Taking into account benzo[a]pyrene mean concentration for the first interval and the first plus the second one, which are the hours with the largest working activity, we have estimated that the baker and co-workers are exposed to a cancer risk of 4.3 × 10 -7 and 5.8 × 10 -7 , respectively (these values are lower than US-EPA recommended guideline of 10 -6 ). Our study was complemented by numerical analyses using state-of-the-art computational fluid dynamics to reconstruct at high resolution air movement from the various working places, i.e., the bakery and the selling area which were connected via a door. The numerical simulations were possible given that surface temperature using infrared thermography as well as air temperature was continuously recorded throughout the sampling acquisition. The use of this approach allowed us to estimate the transport and diffusion of benzo[a]pyrene from one area to the other thus complementing the point sampling information. Computational fluid dynamic simulation results confirm the presence of benzo[a]pyrene in the laboratory as obtained from the measurements and suggests its presence in the sales' area of the bakery with concentrations similar those found in the laboratory.

  3. Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

    NASA Astrophysics Data System (ADS)

    Aubert, Cédric; Osmond, Mélanie

    2008-08-01

    For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it [1]. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as "Interlaboratory Comparisons" for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance. Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements. The STEME organization, in respect of accreditation references, is presented.

  4. Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aubert, Cedric; Osmond, Melanie

    2008-08-14

    For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratorymore » Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements.The STEME organization, in respect of accreditation references, is presented.« less

  5. Evaluation of Urban Air Quality By Passive Sampling Technique

    NASA Astrophysics Data System (ADS)

    Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.

    Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many limitations it is possi- ble to say that the NO2 concentrations were strictly related with traffic intensity and in the centre 3 to 10 times higher values were observed than the incoming air to the city; on the contrary the ozone seems to be consumed where we observe the highest NO2 concentrations. Heal, M. R.; O'Donoghue, M. A. and Cape, J. N., Overestimation of Urban Nitrogen Dioxide by Passive Sampling Tubes: a comparative exposure and model study, Atmo- spheric Environment, Vol 33, pp 513-524, 1999 Monn, Ch., Hangartner, M., Passive Sampling for Ozone, J. of Air and Waste Management Association, Vol. 40, Nz 3, 1990

  6. Influence of storage methods on the surface roughness of tissue conditioners.

    PubMed

    Hong, Guan; Li, YingAi; Maeda, Takeshi; Mizumachi, Wataru; Sadamori, Shinsuke; Hamada, Taizo; Murata, Hiroshi

    2008-03-01

    The purpose of this study was to compare the influence of three kinds of storage methods on surface roughness of tissue conditioners. Four commercial tissue conditioners (GC Soft Liner, Softone, Fictioner, and Hydro-Cast) were used in this study. Five samples of each material were stored in distilled water, air, and a denture cleanser (Polident). Mean surface roughness (R(a)) values of dental stone casts made from the tissue conditioners were measured after 0, 1, 3, 7, and 14 days of immersion using a profilometer. Significant differences in the R(a) values of the specimens were found among the three storage methods. The values of R(a) significantly increased with increase in immersion time for each storage method, except for the materials stored in air. It was found that the materials stored in air showed the most stable and lowest values of R(a). Results obtained suggested that a tissue conditioner exhibited smooth and minimal change in surface roughness with time when stored in air than in distilled water and denture cleanser.

  7. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Air sampling. 61.34 Section 61.34... sampling. (a) Stationary sources subject to § 61.32(b) shall locate air sampling sites in accordance with a... concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...

  8. Correction of Temperatures of Air-Cooled Engine Cylinders for Variation in Engine and Cooling Conditions

    NASA Technical Reports Server (NTRS)

    Schey, Oscar W; Pinkel, Benjamin; Ellerbrock, Herman H , Jr

    1939-01-01

    Factors are obtained from semiempirical equations for correcting engine-cylinder temperatures for variation in important engine and cooling conditions. The variation of engine temperatures with atmospheric temperature is treated in detail, and correction factors are obtained for various flight and test conditions, such as climb at constant indicated air speed, level flight, ground running, take-off, constant speed of cooling air, and constant mass flow of cooling air. Seven conventional air-cooled engine cylinders enclosed in jackets and cooled by a blower were tested to determine the effect of cooling-air temperature and carburetor-air temperature on cylinder temperatures. The cooling air temperature was varied from approximately 80 degrees F. to 230 degrees F. and the carburetor-air temperature from approximately 40 degrees F. to 160 degrees F. Tests were made over a large range of engine speeds, brake mean effective pressures, and pressure drops across the cylinder. The correction factors obtained experimentally are compared with those obtained from the semiempirical equations and a fair agreement is noted.

  9. Biodiversity of air-borne microorganisms at Halley Station, Antarctica.

    PubMed

    Pearce, David A; Hughes, K A; Lachlan-Cope, T; Harangozo, S A; Jones, A E

    2010-03-01

    A study of air-borne microbial biodiversity over an isolated scientific research station on an ice-shelf in continental Antarctica was undertaken to establish the potential source of microbial colonists. The study aimed to assess: (1) whether microorganisms were likely to have a local (research station) or distant (marine or terrestrial) origin, (2) the effect of changes in sea ice extent on microbial biodiversity and (3) the potential human impact on the environment. Air samples were taken above Halley Research Station during the austral summer and austral winter over a 2-week period. Overall, a low microbial biodiversity was detected, which included many sequence replicates. No significant patterns were detected in the aerial biodiversity between the austral summer and the austral winter. In common with other environmental studies, particularly in the polar regions, many of the sequences obtained were from as yet uncultivated organisms. Very few marine sequences were detected irrespective of the distance to open water, and around one-third of sequences detected were similar to those identified in human studies, though both of these might reflect prevailing wind conditions. The detected aerial microorganisms were markedly different from those obtained in earlier studies over the Antarctic Peninsula in the maritime Antarctic.

  10. NHEXAS PHASE I ARIZONA STUDY--METALS IN AIR ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Air data set contains analytical results for measurements of up to 11 metals in 369 air samples over 175 households. Samples were taken by pumping standardized air volumes through filters at indoor and outdoor sites around each household being sampled. The primary...

  11. Summertime tropospheric ozone distributions over central and eastern Canada

    NASA Technical Reports Server (NTRS)

    Anderson, B. E.; Gregory, G. L.; Barrick, J. D.; Collins, J. E., Jr.; Sachse, G. W.; Shipham, M. C.; Hudgins, C. H.

    1994-01-01

    Ozone measurements were obtained between the surface and the 6-km altitude on aircraft flights over central and eastern Canada during the summer 1990 NASA Global Tropospheric Experiment Arctic Boundary Layer Expedition (GTE/ABLE 3B). Tropospheric O3 budgets for these regions were observed to be highly variable and significantly impacted by long-range transport and regional scale air mass modification processes. For example, integrated O3 abundance below 5-km altitude averaged 40% and 30% greater in air masses influenced by anthropogenic sources and biomass burning, respectively, than in background (polar) air. Conversely, aged air transported from subtropical areas of the Pacific at times reduced O3 abundance in this height interval by up to 20%. Though intrusion of anthropogenic air was infrequent during the experiment period, the influence of biomass-burning emissions was particularly notable as two thirds of the flights sampled air influenced by plumes from fires burning in Alaska and western Canada. The impinging pollution, both natural and anthropogenic, not only elevated O3 levels directly but also was a source of reactive nitrogen (and nonmethane hydrocarbons) which generally increases the tropospheric lifetime of O3 via moderation of photochemical destruction rates.

  12. The occurrence of fungi, yeasts and bacteria in the air of a Spanish winery during vintage.

    PubMed

    Garijo, Patrocinio; Santamaría, Pilar; López, Rosa; Sanz, Susana; Olarte, Carmen; Gutiérrez, Ana Rosa

    2008-07-15

    This research studies the presence of microorganisms of enological interest (yeasts, bacteria and molds) and their evolution in the air of a wine cellar. The samples were taken throughout the winemaking campaign (September-December) in a winery of the D.O.Ca. Rioja, Spain. They were collected using an airIDEAL atmosphere sampler from Biomerieux. For the isolation, specific selective media were used for each group of microorganisms. The results obtained indicate that the presence in the winery air of the various different microorganisms studied is directly related to the winemaking processes that are taking place in the winery. Thus, the number of molds present decreases once grapes have ceased to be brought into the winery. The maximum number of yeasts in the air is found when all the vats in the cellar are fermenting, while the lactic bacteria are not detected until the first malolactic fermentation begins. The species of yeasts and molds identified are also related to the winemaking processes. The coincidence of strains of Saccharomyces cerevisiae among those present in the vats during alcoholic fermentation and those isolated from the air, confirms the role of the latter as a transmitter of microorganisms.

  13. HoloGondel: in situ cloud observations on a cable car in the Swiss Alps using a holographic imager

    NASA Astrophysics Data System (ADS)

    Beck, Alexander; Henneberger, Jan; Schöpfer, Sarah; Fugal, Jacob; Lohmann, Ulrike

    2017-02-01

    In situ observations of cloud properties in complex alpine terrain where research aircraft cannot sample are commonly conducted at mountain-top research stations and limited to single-point measurements. The HoloGondel platform overcomes this limitation by using a cable car to obtain vertical profiles of the microphysical and meteorological cloud parameters. The main component of the HoloGondel platform is the HOLographic Imager for Microscopic Objects (HOLIMO 3G), which uses digital in-line holography to image cloud particles. Based on two-dimensional images the microphysical cloud parameters for the size range from small cloud particles to large precipitation particles are obtained for the liquid and ice phase. The low traveling velocity of a cable car on the order of 10 m s-1 allows measurements with high spatial resolution; however, at the same time it leads to an unstable air speed towards the HoloGondel platform. Holographic cloud imagers, which have a sample volume that is independent of the air speed, are therefore well suited for measurements on a cable car. Example measurements of the vertical profiles observed in a liquid cloud and a mixed-phase cloud at the Eggishorn in the Swiss Alps in the winters 2015 and 2016 are presented. The HoloGondel platform reliably observes cloud droplets larger than 6.5 µm, partitions between cloud droplets and ice crystals for a size larger than 25 µm and obtains a statistically significantly size distribution for every 5 m in vertical ascent.

  14. Filter for on-line air monitor unaffected by radon progeny and method of using same

    DOEpatents

    Phillips, Terrance D.; Edwards, Howard D.

    1999-01-01

    An apparatus for testing air having contaminants and radon progeny therein. The apparatus includes a sampling box having an inlet for receiving the air and an outlet for discharging the air. The sampling box includes a filter made of a plate of sintered stainless steel. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough. A method of testing air having contaminants and radon progeny therein. The method includes providing a testing apparatus that has a sampling box with an inlet for receiving the air and an outlet for discharging the air, and has a sintered stainless steel filter disposed within said sampling box; drawing air from a source into the sampling box using a vacuum pump; passing the air through the filter; monitoring the contaminants trapped by the filter; and providing an alarm when a selected level of contaminants is reached. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough.

  15. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    PubMed

    Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  16. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  17. Exposure to ambient air pollution--does it affect semen quality and the level of reproductive hormones?

    PubMed

    Radwan, Michał; Jurewicz, Joanna; Polańska, Kinga; Sobala, Wojciech; Radwan, Paweł; Bochenek, Michał; Hanke, Wojciech

    2016-01-01

    Ambient air pollution has been associated with a variety of reproductive disorders. However, a limited amount of research has been conducted to examine the association between air pollution and male reproductive outcomes, specifically semen quality. The present study was designed to address the hypothesis that exposure to fluctuating levels of specific air pollutants adversely affects sperm parameters and the level of reproductive hormones. The study population consisted of 327 men who were attending an infertility clinic in Łodź, Poland for diagnostic purposes and who had normal semen concentration of 15-300 mln/ml. All participants were interviewed and provided a semen sample. Air quality data were obtained from AirBase database. The statistically significant association was observed between abnormalities in sperm morphology and exposure to all examined air pollutants (PM10, PM2.5, SO2, NOX, CO). Exposure to air pollutants (PM10, PM2.5, CO, NOx) was also negatively associated with the level of testosterone. Additional exposure to PM2.5, PM10 increase the percentage of cells with immature chromatin (HDS). The present study provides suggestive evidence of an association between ambient air pollution and sperm quality. Further research is needed to explore this association in more detail. Individual precise exposure assessment would be needed for more detailed risk characterization.

  18. [Occupational exposure limits for polycyclic aromatic hydrocarbons. Current legal status and proposed changes].

    PubMed

    Brzeźnicki, Sławomir; Bonczarowska, Marzena; Gromiec, Jan P

    2009-01-01

    The evaluation of occupational exposure to polycyclic aromatic hydrocarbons (PAHs) in Poland is based on the results of measurements of their concentrations in workplace air compared to appropriate occupational exposure limits. The inconsistence in current regulations is the source of many interpretation-related problems. The objective of this work was to determine PAH concentrations in different technological processes and to analyze statistically the obtained data to indicate the presence (or absence) of differences between exposure indices calculated for 9 PAHs listed in the decree of the Minister of Labor and those (8 compounds) set by the Minister of Health. Air samples were collected during graphite electrode production, coke production, aluminum smelting, tire production and road paving. PAH concentrations in collected air samples were analyzed by HPLC. The obtained data calculated for each technological process indicate that indices of exposure based on 8 or 9 PAHs, taking into account their relative carcinogenicity, did not differ considerably and are not statistically different from exposure indices calculated for 11 PAHs. In view that the indices of exposure calculated for 8 and 9 compounds are not statistically different and that of all the PAHs listed in the decree of the Minister of Labor, two compounds are not classified as carcinogenic, it seems justified to substitute the latter by the list of compounds issued by the Minister of Health. The proposed modification should result in a better consistency of legal regulations without altering the quality of the occupational exposure evaluation. Furthermore, removing benzo(a)pyrene and dibenzo(ah)anthracene from the OEL list should solve the existing interpretation-related problems.

  19. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN AIR ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Air data set contains analytical results for measurements of up to 11 metals in 344 air samples over 86 households. Samples were taken by pumping standardized air volumes through filters at indoor and outdoor sites around each household being sampled. The primary ...

  20. Investigating African trace gas sources, vertical transport, and oxidation using IAGOS-CARIBIC measurements between Germany and South Africa between 2009 and 2011

    NASA Astrophysics Data System (ADS)

    Thorenz, U. R.; Baker, A. K.; Leedham Elvidge, E. C.; Sauvage, C.; Riede, H.; van Velthoven, P. F. J.; Hermann, M.; Weigelt, A.; Oram, D. E.; Brenninkmeijer, C. A. M.; Zahn, A.; Williams, J.

    2017-06-01

    Between March 2009 and March 2011 a commercial airliner equipped with a custom built measurement container (IAGOS-CARIBIC observatory) conducted 13 flights between South Africa and Germany at 10-12 km altitude, traversing the African continent north-south. In-situ measurements of trace gases (CO, CH4, H2O) and aerosol particles indicated that strong surface sources (like biomass burning) and rapid vertical transport combine to generate maximum concentrations in the latitudinal range between 10°N and 10°S coincident with the inter-tropical convergence zone (ITCZ). Pressurized air samples collected during these flights were subsequently analyzed for a suite of trace gases including C2-C8 non-methane hydrocarbons (NMHC) and halocarbons. These shorter-lived trace gases, originating from both natural and anthropogenic sources, also showed near equatorial maxima highlighting the effectiveness of convective transport in this region. Two source apportionment methods were used to investigate the specific sources of NMHC: positive matrix factorization (PMF), which is used for the first time for NMHC analysis in the upper troposphere (UT), and enhancement ratios to CO. Using the PMF method three characteristic airmass types were identified based on the different trace gas concentrations they obtained: biomass burning, fossil fuel emissions, and "background" air. The first two sources were defined with reference to previously reported surface source characterizations, while the term "background" was given to air masses in which the concentration ratios approached that of the lifetime ratios. Comparison of enhancement ratios between NMHC and CO for the subset of air samples that had experienced recent contact with the planetary boundary layer (PBL) to literature values showed that the burning of savanna and tropical forest is likely the main source of NMHC in the African upper troposphere (10-12 km). Photochemical aging patterns for the samples with PBL contact revealed that the air had different degradation histories depending on the hemisphere in which they were emitted. In the southern hemisphere (SH) air masses experienced more dilution by clean background air whereas in the northern hemisphere (NH) air masses are less diluted or mixed with background air still containing longer lived NMHC. Using NMHC photochemical clocks ozone production was seen in the BB outflow above Africa in the NH.

  1. Hemolymph amino acid analysis of individual Drosophila larvae.

    PubMed

    Piyankarage, Sujeewa C; Augustin, Hrvoje; Grosjean, Yael; Featherstone, David E; Shippy, Scott A

    2008-02-15

    One of the most widely used transgenic animal models in biology is Drosophila melanogaster, the fruit fly. Chemical information from this exceedingly small organism is usually accomplished by studying populations to attain sample volumes suitable for standard analysis methods. This paper describes a direct sampling technique capable of obtaining 50-300 nL of hemolymph from individual Drosophila larvae. Hemolymph sampling performed under mineral oil and in air at 30 s intervals up to 120 s after piercing larvae revealed that the effect of evaporation on amino acid concentrations is insignificant when the sample was collected within 60 s. Qualitative and quantitative amino acid analyses of obtained hemolymph were carried out in two optimized buffer conditions by capillary electrophoresis with laser-induced fluorescence detection after derivatizing with fluorescamine. Thirteen amino acids were identified from individual hemolymph samples of both wild-type (WT) control and the genderblind (gb) mutant larvae. The levels of glutamine, glutamate, and taurine in the gb hemolymph were significantly lower at 35%, 38%, and 57% of WT levels, respectively. The developed technique that samples only the hemolymph fluid is efficient and enables accurate organism-level chemical information while minimizing errors associated with possible sample contaminations, estimations, and effects of evaporation compared to the traditional hemolymph-sampling techniques.

  2. Optical Emission Studies of Copper Plasma Induced Using Infrared Transversely Excited Atmospheric (IR TEA) Carbon Dioxide Laser Pulses.

    PubMed

    Momcilovic, Milos; Kuzmanovic, Miroslav; Rankovic, Dragan; Ciganovic, Jovan; Stoiljkovic, Milovan; Savovic, Jelena; Trtica, Milan

    2015-04-01

    Spatially resolved, time-integrated optical emission spectroscopy was applied for investigation of copper plasma produced by a nanosecond infrared (IR) transversely excited atmospheric (TEA) CO2 laser, operating at 10.6 μm. The effect of surrounding air pressure, in the pressure range 0.1 to 1013 mbar, on plasma formation and its characteristics was investigated. A linear dependence of intensity threshold for plasma formation on logarithm of air pressure was found. Lowering of the air pressure reduces the extent of gas breakdown, enabling better laser-target coupling and thus increases ablation. Optimum air pressure for target plasma formation was 0.1 mbar. Under that pressure, the induced plasma consisted of two clearly distinguished and spatially separated regions. The maximum intensity of emission, with sharp and well-resolved spectral lines and negligibly low background emission, was obtained from a plasma zone 8 mm from the target surface. The estimated excitation temperature in this zone was around 7000 K. The favorable signal to background ratio obtained in this plasma region indicates possible analytical application of TEA CO2 laser produced copper plasma. Detection limits of trace elements present in the Cu sample were on the order of 10 ppm (parts per million). Time-resolved measurements of spatially selected plasma zones were used to find a correlation between the observed spatial position and time delay.

  3. Spatial and seasonal distribution of polychlorinated biphenyls (PCBs) in the vicinity of an iron and steel making plant.

    PubMed

    Baek, Song-Yee; Choi, Sung-Deuk; Park, Hyokeun; Kang, Jung-Ho; Chang, Yoon-Seok

    2010-04-15

    Four consecutive passive air samplings (September 2006-July 2007) were conducted at 15 sites around an iron and steel making plant in Pohang, Korea to investigate the spatial and seasonal distributions of polychlorinated biphenyls (PCBs) and ultimately the source-receptor relationships. Annual mean values of Sigma(8)PCBs (IUPAC number 8, 28, 52, 101, 118, 138, 153, 180) were in the range of 15.1-166 pg/m(3) with an average of 53.0 pg/m(3). The spatial distribution of PCBs for each sampling period clearly suggests that the steel complex is a major source of PCBs in this area, and the prevailing winds facilitated the atmospheric transport and dispersion of PCBs from the steel complex to the surrounding areas. Seasonal patterns of PCBs were observed clearly, which were influenced by meteorological conditions; the highest levels of PCBs were observed with the highest average air temperature, and the influence of rainfall (i.e., wet scavenging) was also observed. In addition, PCB 11, a non-Aroclor congener, was detected in high concentrations at all sites, implying that the sources of PCB 11 are both unique and ubiquitous. This study confirms that passive air sampling is a useful tool to obtain seasonal and spatial distributions of time-averaged POPs data at a local scale.

  4. Quantification and Characterization of Volatiles Evolved During Extrusion of Rice and Soy Flours

    NASA Technical Reports Server (NTRS)

    Zasypkin, D.; Lertsiriyothin, W.; Lee, T. C.; Bourland, C. T.; Bond, Robert L. (Technical Monitor)

    1999-01-01

    NASA Johnson Space Center is designing and building a habitat (Bioregenerative Planetary Life Support Systems Test Complex, BIO-Plex) intended for evaluating advanced life support systems developed for long duration missions to the Moon or Mars where all consumables will be recycled and reused. A food system based on raw products obtained from higher plants (such as soybeans, rice and wheat) may be a central feature of a biological ly-based Advanced Life Support System (ALSS). In order to convert raw crops to edible ingredients or food items, multipurpose processing equipment such as an extruder is ideal. Volatile compounds evolved during the manufacturing of these food products may accumulate reaching toxic levels. Additionally, off-odors often dissipated in open-air environments without consequence, may cause significant discomfort in the BIO-Plex. Rice and defatted soy flours were adjusted to 16% moisture and triplicate samples were extruded using a table top single-screw extruder. The extrudate was collected in specially designed Tedlar bags from which air samples could be extracted. The samples were analyzed by GC-MS with special emphasis on compounds with Spacecraft Maximum Allowable Concentrations (SMAC). Results showed a combination of alcohols, aldehydes, ketones and carbonyl compounds in the different flours. Each compound and its SMAC value as well as its impact on the air revitalization system was discussed.

  5. Comparative Study of the Effect of Sample Pretreatment and Extraction on the Determination of Flavonoids from Lemon (Citrus limon)

    PubMed Central

    Ledesma-Escobar, Carlos A.; Priego-Capote, Feliciano; Luque de Castro, María D.

    2016-01-01

    Background Flavonoids have shown to exert multiple beneficial effects on human health, being also appreciated by both food and pharmaceutical industries. Citrus fruits are a key source of flavonoids, thus promoting studies to obtain them. Characteristics of these studies are the discrepancies among sample pretreatments and among extraction methods, and also the scant number of comparative studies developed so far. Objective Evaluate the effect of both the sample pretreatment and the extraction method on the profile of flavonoids isolated from lemon. Results Extracts from fresh, lyophilized and air-dried samples obtained by shaking extraction (SE), ultrasound-assisted extraction (USAE), microwave-assisted extraction (MAE) and superheated liquid extraction (SHLE) were analyzed by LC–QTOF MS/MS, and 32 flavonoids were tentatively identified using MS/MS information. ANOVA applied to the data from fresh and dehydrated samples and from extraction by the different methods revealed that 26 and 32 flavonoids, respectively, were significant (p≤0.01). The pairwise comparison (Tukey HSD; p≤0.01) showed that lyophilized samples are more different from fresh samples than from air-dried samples; also, principal component analysis (PCA) showed a clear discrimination among sample pretreatment strategies and suggested that such differences are mainly created by the abundance of major flavonoids. On the other hand, pairwise comparison of extraction methods revealed that USAE and MAE provided quite similar extracts, being SHLE extracts different from the other two. In this case, PCA showed a clear discrimination among extraction methods, and their position in the scores plot suggests a lower abundance of flavonoids in the extracts from SHLE. In the two PCA the loadings plots revealed a trend to forming groups according to flavonoid aglycones. Conclusions The present study shows clear discrimination caused by both sample pretreatments and extraction methods. Under the studied conditions, liophilization provides extracts with higher amounts of flavonoids, and USAE is the best method for isolation of these compounds, followed by MAE and SE. On the contrary, the SHLE method was the less favorable to extract flavonoids from citrus owing to degradation. PMID:26807979

  6. Identification of water-bearing zones by the use of geophysical logs and borehole television surveys, collected February to September 1997, at the Former Naval Air Warfare Center, Warminster, Bucks County, Pennsylvania

    USGS Publications Warehouse

    Conger, Randall W.

    1998-01-01

    Between February 1997 and September 1997, 10 monitor wells were drilled near the site of the former Naval Air Warfare Center, Warminster, Bucks County, Pa., to monitor water levels and sample ground-water contaminants in the shallow, intermediate, and deep water-bearing zones. The sampling will determine the horizontal and vertical distribution of contaminated ground water migrating from known or suspected contaminant sources. Four wells were drilled north of the property adjacent to Area A, three wells along strike located on Lewis Drive, and three wells directly down dip on Ivyland Road. Well depths range from 69 feet to 300 feet below land surface.Borehole-geophysical logging and television surveys were used to identify water-bearing zones so that appropriate intervals could be screened in each monitor well. Geophysical logs were obtained at the 10 monitor wells. Borehole television surveys were obtained at the four monitor wells adjacent to Area A.Caliper and borehole television surveys were used to locate fractures, inflections on fluidtemperature and fluid-resistivity logs were used to locate possible water-bearing fractures, and heatpulse- flowmeter measurements verified these locations. Natural-gamma logs provided information on stratigraphy. After interpretation of geophysical logs, borehole television surveys, and driller's logs, all wells were screened such that water-level fluctuations could be monitored and water samples collected from discrete water-bearing zones in each borehole.

  7. Identification of water-bearing fractures by the use of geophysical logs, May to July 1998, former Naval Air Warfare Center, Bucks County, Pennsylvania

    USGS Publications Warehouse

    Conger, Randall W.; Bird, Philip H.

    1999-01-01

    Between May and July 1998, 10 monitor wells were drilled near the site of the former Naval Air Warfare Center (NAWC), Warminster, Bucks County, Pa., to monitor water levels and sample ground water in shallow and intermediate water-bearing fractures. The sampling will determine the horizontal and vertical distribution of contaminated ground water migrating from known or suspected sources. Three boreholes were drilled on the property at 960 Jacksonville Road, at the northwestern side of NAWC, along strike from Area A; seven boreholes were drilled in Area B in the southeastern corner of NAWC. Depths range from 40.5 to 150 feet below land surface.Borehole geophysical logging and video surveys were used to identify water-bearing fractures so that appropriate intervals could be screened in each monitor well. Geophysical logs were obtained at the 10 monitor wells. Video surveys were obtained at three monitor wells in the southeastern corner of the NAWC property.Caliper logs and video surveys were used to locate fractures. Inflections on fluid-temperature and fluid-resistivity logs were used to locate possible water-bearing fractures. Heatpulse-flowmeter measurements verified these locations. Natural-gamma logs provided information on stratigraphy. After interpretation of geophysical logs, video surveys, and driller's logs, all wells were screened such that water-level fluctuations could be monitored and water samples collected from discrete water-bearing fractures in each monitor well.

  8. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF FILTERS AND PUF FOR FIELD COLLECTION OF METALS AND PESTICIDES IN AIR (BCO-L-2.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...

  9. Thermal characterization of organic matter along a (hypothetical) coalification gradient

    NASA Astrophysics Data System (ADS)

    Cavallo, Ornella; Provenzano, Maria Rosaria; Zaccone, Claudio

    2017-04-01

    Geochemical transformations of organic carbon (C) in aquatic and terrestrial ecosystems are important starting points for genesis of peats, brown coals and other coal precursors. The humification process plays a key role in biogeochemical transformations of organic C and, as a result, in the first stages of coal precursors formation. Thermal analysis was used by Schnitzer and other scientists since 1950-1960s, in order to investigate the stability of several organic materials of industrial value including peat and coal. What soil scientists found was the general occurrence of two exothermic peaks (exotherm 1 and 2) due to decomposition and combustion reactions of organic compounds having different thermal stability and, consequently, different degree of humification. Thermogravimetric analysis (TG) was carried out on different samples reproducing a "hypothetical" coalification gradient as follows: peat (IHSS Pahokee peat standard), fulvic acid (FA), a peat humic acid (HA), leonardite (IHSS Gascoyne standard) and charcoal. An aliquot of about 20 mg of each sample was heated in a ceramic crucible from 50 to 850˚ C at 30˚ C min-1, at a gas flow rate of 30 mL min-1 using a PerkinElmer TGA4000 thermobalance. Samples were analysed both under nitrogen and under synthetic air. All analyses were carried out in triplicate and the average coefficient of variation was <1.5%. Weight losses (in %) were determined within 200-400˚ C (WL1) and 400-600˚ C (WL2) temperature ranges, and the ratio between WL2/WL1 calculated for all samples. This ratio has been often used as a highly sensitive parameter to describe chemical changes induced by the bio-transformation of organic materials. Finally, the temperature at which half of the exothermic mass loss has occurred (TG-T50) was also calculated. Preliminary results obtained from TG analysis under air showed that WL2/WL1 ratio was lower for the FA sample and higher for leonardite and charcoal, following the order FA

  10. Screen printed, transparent, and flexible electrodes based on graphene nanoplatelet pastes

    NASA Astrophysics Data System (ADS)

    Wróblewski, Grzegorz; Janczak, Daniel

    Transparent, flexible and conducting graphene films were produced by screen printing method using printing pastes based on graphene nanoplatelets in polymer matrix. The transparency of received layers and the mechanical resistivity in several bending cycles were measured. Subsequently percolation threshold was investigated. Graphene layers were printed on diverse substrates (glass, Al2O3, PET) and afterwards for samples printed on glass different firing atmospheres (N2, H2, air) were studied. Best firing results (resistance decrease) were obtained for treatment in 250 °C in atmosphere of air. Finally investigation results were used to produce a transparent and elastic electrode for an electroluminescent display, showing the application potential of our graphene nanocomposite pastes.

  11. Results from KASCADE-Grande

    NASA Astrophysics Data System (ADS)

    Bertaina, M.; Apel, W. D.; Arteaga-Velázquez, J. C.; Bekk, K.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Buchholz, P.; Cantoni, E.; Chiavassa, A.; Cossavella, F.; Daumiller, K.; de Souza, V.; Di Pierro, F.; Doll, P.; Engel, R.; Engler, J.; Finger, M.; Fuhrmann, D.; Ghia, P. L.; Gils, H. J.; Glasstetter, R.; Grupen, C.; Haungs, A.; Heck, D.; Hörandel, J. R.; Huber, D.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Klages, H. O.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Mayer, H. J.; Melissas, M.; Milke, J.; Mitrica, B.; Morello, C.; Navarra, G.; Oehlschläger, J.; Ostapchenko, S.; Over, S.; Palmieri, N.; Petcu, M.; Pierog, T.; Rebel, H.; Roth, M.; Schieler, H.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Ulrich, H.; Weindl, A.; Wochele, J.; Wommer, M.; Zabierowski, J.

    2012-11-01

    The KASCADE-Grande experiment, located at Karlsruhe Institute of Technology (Germany) is a multi-component extensive air-shower experiment devoted to the study of cosmic rays and their interactions at primary energies 1014-1018 eV. Main goals of the experiment are the measurement of the all-particle energy spectrum and mass composition in the 1016-1018 eV range by sampling charged (Nch) and muon (Nμ) components of the air shower. The method to derive the energy spectrum and its uncertainties, as well as the implications of the obtained result, is discussed. An overview of the analyses performed by KASCADE-Grande to derive the mass composition of the measured high-energy comic rays is presented as well.

  12. The influence of convection drying on the physicochemical properties of yacón (Smallanthus sonchifolius)

    NASA Astrophysics Data System (ADS)

    Salinas, Juan Gabriel; Alvarado, Juan Antonio; Bergenståhl, Björn; Tornberg, Eva

    2018-04-01

    Yacón root is a natural source of fructans, which has many potential benefits. Convective drying has been applied to increase the shelf life of yacón roots. However, this processing may lead to detrimental effects on the physicochemical functionality. The drying was investigated using different conditions (drying temperatures of 45 °C, 50 °C and 55 °C at a drying air velocity of 2 m/s and 60 °C at a drying air velocity of 2 m/s, 3 m/s and 4 m/s). The dried samples were compared to the original yacón with regard to their physicochemical properties. From all the properties that were studied, the color of the dried material and the elastic modulus of the reconstituted yacón were the most important properties being minimized respectively. The results of this investigation indicate that the best drying conditions, where the physicochemical properties of the samples are kept closest to the original material, are obtained either by using temperatures of 55 °C and 2 m/s or using higher temperatures but increasing the air velocity.

  13. China action of "Cleanup Plan for Polychlorinated Biphenyls Burial Sites": emissions during excavation and thermal desorption of a capacitor-burial site.

    PubMed

    Yang, Bing; Zhou, Lingli; Xue, Nandong; Li, Fasheng; Wu, Guanglong; Ding, Qiong; Yan, Yunzhong; Liu, Bo

    2013-10-01

    Scarce data are available so far on emissions in a given scenario for excavation and thermal desorption, a common practice, of soils contaminated with polychlorinated biphenyls (PCBs). As part of China action of "Cleanup Plan for PCBs Burial Sites", this study roughly estimated PCBs emissions in the scenario for a capacitor-burial site. The concentrations of total PCBs (22 congeners) in soils were in the range of 2.1-16,000μg/g with a mean of 2300μg/g, among the same order of magnitude as the highest values obtained in various PCBs-contaminated sites. Only six congeners belonging to Di-, Tri-, and Tetra-CBs were observed above limits of detection in air samples in the scenario, partially which can be estimated by the USEPA air emission model. Comparing concentrations and composition profiles of PCBs in the soil and air samples further indicated a leaked source of commercial PCBs formulations of trichlorobiphenyl (China PCB no. 1). The measures taken if any to mitigate the volatilization and movement of PCBs and to minimize worker exposure were discussed for improvements of the excavation practice. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. A study of optimum cowl shapes and flow port locations for minimum drag with effective engine cooling, volume 2

    NASA Technical Reports Server (NTRS)

    Fox, S. R.; Smetana, F. O.

    1980-01-01

    The listings, user's instructions, sample inputs, and sample outputs of two computer programs which are especially useful in obtaining an approximate solution of the viscous flow over an arbitrary nonlifting three dimensional body are provided. The first program performs a potential flow solution by a well known panel method and readjusts this initial solution to account for the effects of the boundary layer displacement thickness, a nonuniform but unidirectional onset flow field, and the presence of air intakes and exhausts. The second program is effectually a geometry package which allows the user to change or refine the shape of a body to satisfy particular needs without a significant amount of human intervention. An effort to reduce the cruise drag of light aircraft through an analytical study of the contributions to the drag arising from the engine cowl shape and the foward fuselage area and also that resulting from the cooling air mass flowing through intake and exhaust sites on the nacelle is presented. The programs may be effectively used to determine the appropriate body modifications or flow port locations to reduce the cruise drag as well as to provide sufficient air flow for cooling the engine.

  15. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P.; Gustafsson, U. R. C.

    1975-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of selected particulate and gaseous constituents of the atmosphere has been installed on a number of commercial airliners and is collecting data on commercial air routes covering the world. Measurements of constituents related to aircraft engine emissions and other pollutants are made in the upper troposphere and lower stratosphere (6 to 12 km) in support of the Global Air Sampling Program (GASP). Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This system includes specialized instrumentation for measuring carbon monoxide, ozone, water vapor, and particulates, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituents and related flight data are tape recorded in flight for later computer processing on the ground.

  16. Influence of size-fractioning techniques on concentrations of selected trace metals in bottom materials from two streams in northeastern Ohio

    USGS Publications Warehouse

    Koltun, G.F.; Helsel, Dennis R.

    1986-01-01

    Identical stream-bottom material samples, when fractioned to the same size by different techniques, may contain significantly different trace-metal concentrations. Precision of techniques also may differ, which could affect the ability to discriminate between size-fractioned bottom-material samples having different metal concentrations. Bottom-material samples fractioned to less than 0.020 millimeters by means of three common techniques (air elutriation, sieving, and settling) were analyzed for six trace metals to determine whether the technique used to obtain the desired particle-size fraction affects the ability to discriminate between bottom materials having different trace-metal concentrations. In addition, this study attempts to assess whether median trace-metal concentrations in size-fractioned bottom materials of identical origin differ depending on the size-fractioning technique used. Finally, this study evaluates the efficiency of the three size-fractioning techniques in terms of time, expense, and effort involved. Bottom-material samples were collected at two sites in northeastern Ohio: One is located in an undeveloped forested basin, and the other is located in a basin having a mixture of industrial and surface-mining land uses. The sites were selected for their close physical proximity, similar contributing drainage areas, and the likelihood that trace-metal concentrations in the bottom materials would be significantly different. Statistically significant differences in the concentrations of trace metals were detected between bottom-material samples collected at the two sites when the samples had been size-fractioned by means of air elutriation or sieving. Statistical analyses of samples that had been size fractioned by settling in native water were not measurably different in any of the six trace metals analyzed. Results of multiple comparison tests suggest that differences related to size-fractioning technique were evident in median copper, lead, and iron concentrations. Technique-related differences in copper concentrations most likely resulted from contamination of air-elutriated samples by a feed tip on the elutriator apparatus. No technique-related differences were observed in chromium, manganese, or zinc concentrations. Although air elutriation was the most expensive sizefractioning technique investigated, samples fractioned by this technique appeared to provide a superior level of discrimination between metal concentrations present in the bottom materials of the two sites. Sieving was an adequate lower-cost but more laborintensive alternative.

  17. Baseline results from the Lichen Community Indicator Program in the Pacific Northwest: Air quality patterns and evidence of a nitrogen pollution problem

    Treesearch

    Sarah Jovan

    2009-01-01

    Why Are Epiphytic Lichen Communities Important? Lichens are one of the bioindicators used by the Forest Inventory and Analysis (FIA) Program to monitor forest health. To obtain data for use in its Lichen Community Indicator Program, FIA samples a regular network of permanent field plots to determine the composition of epiphytic, i.e., tree dwelling, lichen communities...

  18. VHSIC Electronics and the Cost of Air Force Avionics in the 1990s

    DTIC Science & Technology

    1990-11-01

    circuit. LRM Line replaceable module. LRU Line replaceable unit. LSI Large-scale integration. LSTTL Tow-power Schottky Transitor -to-Transistor Logic...displays, communications/navigation/identification, electronic combat equipment, dispensers, and computers. These CERs, which statistically relate the...some of the reliability numbers, and adding the F-15 and F-16 to obtain the data sample shown in Table 6. Both suite costs and reliability statistics

  19. Terahertz surface plasmon resonance sensor for material sensing

    NASA Astrophysics Data System (ADS)

    Hailu, Daniel M.; Alqarni, Sondos; Cui, Bo; Saeedkia, Daryoosh

    2013-10-01

    This paper presents the use of Terahertz (THz) SPR near-field sensor to characterize materials such as PMMA and those used in organic light emitting diode (OLED). The SPR device contains 2D periodic circular or square hole array in 500 nm Al on an 5 mm-thick intrinsic silicon, and was fabricated by photolithography and wet etching. For THz spectrum measurement, the SPR device with and without thin (PMMA) film on it is placed at the focus of the THz beam in transmission THz Time Domain Spectroscopy (TDS), where the spectrum is obtained from the Fourier-transformed sample and reference THz pulses. The transmission is obtained from the ratio between the sample spectrum and reference spectrum, whereas the phase change is the phase difference between the two spectra. To avoid overlap with water absorption lines, the optimal SPR device design has a period of 320 μm and square holes of 150 μm side length. The theoretical SPR frequencies in the THz range are determined for the metal-silicon modes and metal-air modes (0.9375 THz for mode (0, 1) at the metal-air interface). The measurement results confirmed the theoretical SPR frequencies for metal-silicon mode and demonstrate a shift to 0.9211 THz due to 2 μm of PMMA layer on the surface.

  20. Respirable concrete dust--silicosis hazard in the construction industry.

    PubMed

    Linch, Kenneth D

    2002-03-01

    Concrete is an extremely important part of the infrastructure of modern life and must be replaced as it ages. Many of the methods of removing, repairing, or altering existing concrete structures have the potential for producing vast quantities of respirable dust. Since crystalline silica in the form of quartz is a major component of concrete, airborne respirable quartz dust may be produced during construction work involving the disturbance of concrete, thereby producing a silicosis hazard for exposed workers. Silicosis is a debilitating and sometimes fatal lung disease resulting from breathing microscopic particles of crystalline silica. Between 1992 and 1998, the National Institute for Occupational Safety and Health (NIOSH) made visits to construction projects where concrete was being mechanically disturbed in order to obtain data concerning respirable crystalline silica dust exposures. The construction activities studied included: abrasive blasting, concrete pavement sawing and drilling, and asphalt/concrete milling. Air samples of respirable dust were obtained using 10-mm nylon cyclone pre-separators, 37-mm polyvinyl chloride (PVC) filters, and constant-flow pumps calibrated at 1.7 L/min. In addition, high-volume respirable dust samples were obtained on 37-mm PVC filters using 1/2" metal cyclones (Sensidyne model 18) and constant-flow pumps calibrated at 9.0 L/min. Air sample analysis included total weight gain by gravimetric analysis according to NIOSH Analytical Method 600 and respirable crystalline silica (quartz and cristobalite) using x-ray diffraction, as per NIOSH Analytical Method 7500. For abrasive blasting of concrete structures, the respirable crystalline silica (quartz) concentration ranged up to 14.0 mg/m3 for a 96-minute sample resulting in an eight-hour time-weighted average (TWA) of 2.8 mg/m3. For drilling concrete highway pavement the respirable quartz concentrations ranged up to 4.4 mg/m3 for a 358-minute sample, resulting in an eight-hour TWA of 3.3 mg/m3. For concrete wall grinding during new building construction the respirable quartz measurements ranged up to 0.66 mg/m3 for a 191-minute sample, resulting in an eight-hour TWA of 0.26 mg/m3. The air sampling results for concrete sawing ranged up to 14.0 mg/m3 for a 350-minute sample resulting in an eight-hour TWA of 10.0 mg/m3. During the milling of asphalt from concrete highway pavement, the sampling indicated a respirable quartz concentration ranging up to 0.34 mg/m3 for a 504-minute sample, resulting in an eight-hour TWA of 0.36 mg/m3. The results of this work indicate the potential for respirable quartz concentrations involving disturbance of concrete to range up to 280 times the NIOSH Recommended Exposure Limit (REL) of 0.05 mg/m3 assuming exposure for an eight- to ten-hour workday. Considering the aging of the concrete infrastructure in the United States, these results pose a challenge to all who have an interest in preventing silica exposures and the associated disease silicosis.

  1. Personal exposure to JP-8 jet fuel vapors and exhaust at air force bases.

    PubMed Central

    Pleil, J D; Smith, L B; Zelnick, S D

    2000-01-01

    JP-8 jet fuel (similar to commercial/international jet A-1 fuel) is the standard military fuel for all types of vehicles, including the U.S. Air Force aircraft inventory. As such, JP-8 presents the most common chemical exposure in the Air Force, particularly for flight and ground crew personnel during preflight operations and for maintenance personnel performing routine tasks. Personal exposure at an Air Force base occurs through occupational exposure for personnel involved with fuel and aircraft handling and/or through incidental exposure, primarily through inhalation of ambient fuel vapors. Because JP-8 is less volatile than its predecessor fuel (JP-4), contact with liquid fuel on skin and clothing may result in prolonged exposure. The slowly evaporating JP-8 fuel tends to linger on exposed personnel during their interaction with their previously unexposed colleagues. To begin to assess the relative exposures, we made ambient air measurements and used recently developed methods for collecting exhaled breath in special containers. We then analyzed for certain volatile marker compounds for JP-8, as well as for some aromatic hydrocarbons (especially benzene) that are related to long-term health risks. Ambient samples were collected by using compact, battery-operated, personal whole-air samplers that have recently been developed as commercial products; breath samples were collected using our single-breath canister method that uses 1-L canisters fitted with valves and small disposable breathing tubes. We collected breath samples from various groups of Air Force personnel and found a demonstrable JP-8 exposure for all subjects, ranging from slight elevations as compared to a control cohort to > 100 [mutilpe] the control values. This work suggests that further studies should be performed on specific issues to obtain pertinent exposure data. The data can be applied to assessments of health outcomes and to recommendations for changes in the use of personal protective equipment that optimize risk reduction without undue impact on a mission. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 PMID:10706522

  2. HIGH VOLUME INJECTION FOR GCMS ANALYSIS OF PARTICULATE ORGANIC SPECIES IN AMBIENT AIR

    EPA Science Inventory

    Detection of organic species in ambient particulate matter typically requires large air sample volumes, frequently achieved by grouping samples into monthly composites. Decreasing the volume of air sample required would allow shorter collection times and more convenient sample c...

  3. Evaluation of microbiological air quality and of microclimate in university classrooms.

    PubMed

    Grisoli, Pietro; Rodolfi, Marinella; Chiara, Tiziana; Zonta, Laura Attinia; Dacarro, Cesare

    2012-07-01

    The proliferation of air-diffused microorganisms inside public buildings such as schools, hospitals, and universities, is often indicated as a possible health risk. In this research, we have illustrated the results of an investigation realized to determine the health of the air in some university classrooms, both from a microbiological and a microclimatic viewpoint, during the normal didactic activity of direct lessons. The results obtained have been expressed by means of contamination indices, already used in previous works. Very little contamination was recorded in the different phases of air treatment, which underlines the efficiency of the system and of the maintenance protocols. The Global Index of Microbial Contamination (GIMC per cubic meter) showed a value greater than the mean during the heating period (290), while the highest values (95th percentile 1,138.45) were recorded in the period using air conditioning. The index of mesophilic bacterial contamination, though it did not show any significant differences in the various modes of air treatment, showed a mean value (1.34) and the 95th percentile value (4.14), which was greater in the air-conditioning phase. Finally, the mean value of the amplification index underlined a decrease in the microbial contamination in comparison to the outside, while showing situations of increased microbial amplification during the period of simple ventilation (95th percentile 4.27). The 95th percentile values found for GICM in the three sampling periods, however, permitted us to identify the value of GIMC per cubic meter equal to 1,000 as a guide to provide a means of self-monitoring the quality of the air inside the classrooms. From a microclimatic viewpoint, two periods of the year manifested discomfort situations: during the heating phase (winter) and during the simple ventilation phase (spring). The results obtained indicate, therefore, a need to intervene on the environmental parameters, not being able, in this particular case, to intervene on other aspects that influence the microclimate.

  4. PROGRA2 experiment: New results for dust clouds and regoliths analogs

    NASA Astrophysics Data System (ADS)

    Hadamcik, E.; Renard, J.-B.; Levasseur-Regourd, A. C.; Worms, J.-C.

    2006-01-01

    With the PROGRA2 experience, linear polarization of scattered light is measured on various types of dust clouds lifted by microgravity, or by an air-draught. The aim is to compare the phase curves for dust analogs with those obtained in the Solar System (cometary comae, and solid particles in planetary atmospheres) by remote-sensing and in situ techniques. Measurements are also performed on layers of particles (on the ground) and compared with remote measurements on asteroidal regoliths and planetary surfaces. New phase curves have been obtained, e.g., for quartz samples, crystals, fluffy mixtures of silica and carbon blacks and a high porosity regolith analog made of micron-sized silica spheres. This work will contribute to the choice of the samples to be studied with the ICAPS experiment onboard the ISS and on the precursor experiment.

  5. Particle impactor assembly for size selective high volume air sampler

    DOEpatents

    Langer, Gerhard

    1988-08-16

    Air containing entrained particulate matter is directed through a plurality of parallel, narrow, vertically oriented impactor slots of an inlet element toward an adjacently located, relatively large, dust impaction surface preferably covered with an adhesive material. The air flow turns over the impaction surface, leaving behind the relatively larger particles according to the human thoracic separation system and passes through two elongate exhaust apertures defining the outer bounds of the impaction collection surface to pass through divergent passages which slow down and distribute the air flow, with entrained smaller particles, over a fine filter element that separates the fine particles from the air. The elongate exhaust apertures defining the impaction collection surface are spaced apart by a distance greater than the lengths of elongate impactor slots in the inlet element and are oriented to be normal thereto. By appropriate selection of dimensions and the number of impactor slots air flow through the inlet element is provided a nonuniform velocity distribution with the lower velocities being obtained near the center of the impactor slots, in order to separate out particles larger than a certain predetermined size on the impaction collection surface. The impaction collection surface, even in a moderately sized apparatus, is thus relatively large and permits the prolonged sampling of air for periods extending to four weeks.

  6. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  7. Carter Carburetor Weekly Air Monitoring & Sampling Report - March 7, 2013 - March 13, 2016

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  8. Demonstration and Optimization of BNFL's Pulsed Jet Mixing and RFD Sampling Systems Using NCAW Simulant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    JR Bontha; GR Golcar; N Hannigan

    2000-08-29

    The BNFL Inc. flowsheet for the pretreatment and vitrification of the Hanford High Level Tank waste includes the use of several hundred Reverse Flow Diverters (RFDs) for sampling and transferring the radioactive slurries and Pulsed Jet mixers to homogenize or suspend the tank contents. The Pulsed Jet mixing and the RFD sampling devices represent very simple and efficient methods to mix and sample slurries, respectively, using compressed air to achieve the desired operation. The equipment has no moving parts, which makes them very suitable for mixing and sampling highly radioactive wastes. However, the effectiveness of the mixing and sampling systemsmore » are yet to be demonstrated when dealing with Hanford slurries, which exhibit a wide range of physical and theological properties. This report describes the results of the testing of BNFL's Pulsed Jet mixing and RFD sampling systems in a 13-ft ID and 15-ft height dish-bottomed tank at Battelle's 336 building high-bay facility using AZ-101/102 simulants containing up to 36-wt% insoluble solids. The specific objectives of the work were to: Demonstrate the effectiveness of the Pulsed Jet mixing system to thoroughly homogenize Hanford-type slurries over a range of solids loading; Minimize/optimize air usage by changing sequencing of the Pulsed Jet mixers or by altering cycle times; and Demonstrate that the RFD sampler can obtain representative samples of the slurry up to the maximum RPP-WTP baseline concentration of 25-wt%.« less

  9. Air sampling workshop: October 24-25, 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-06-01

    A two-day workshop was held in October 1978 on air sampling strategies for the occupational environment. Strategies comprise the elements of implementing an air sampling program including deciding on the extent of sampling, selecting appropriate types of measurement, placing sampling instruments properly, and interpreting sample results correctly. All of these elements are vital in the reliable assessment of occupational exposures yet their coverage in the industrial hygiene literature is meager. Although keyed to a few introductory topics, the agenda was sufficiently informal to accommodate extemporaneous discussion on any subject related to sampling strategies. Questions raised during the workshop mirror themore » status of air sampling strategy as much as the factual information that was presented. It may be concluded from the discussion and questions that air sampling strategy is an elementary state and urgently needs concerted attention from the industrial hygiene profession.« less

  10. A novel, fuzzy-based air quality index (FAQI) for air quality assessment

    NASA Astrophysics Data System (ADS)

    Sowlat, Mohammad Hossein; Gharibi, Hamed; Yunesian, Masud; Tayefeh Mahmoudi, Maryam; Lotfi, Saeedeh

    2011-04-01

    The ever increasing level of air pollution in most areas of the world has led to development of a variety of air quality indices for estimation of health effects of air pollution, though the indices have their own limitations such as high levels of subjectivity. Present study, therefore, aimed at developing a novel, fuzzy-based air quality index (FAQI ) to handle such limitations. The index developed by present study is based on fuzzy logic that is considered as one of the most common computational methods of artificial intelligence. In addition to criteria air pollutants (i.e. CO, SO 2, PM 10, O 3, NO 2), benzene, toluene, ethylbenzene, xylene, and 1,3-butadiene were also taken into account in the index proposed, because of their considerable health effects. Different weighting factors were then assigned to each pollutant according to its priority. Trapezoidal membership functions were employed for classifications and the final index consisted of 72 inference rules. To assess the performance of the index, a case study was carried out employing air quality data at five different sampling stations in Tehran, Iran, from January 2008 to December 2009, results of which were then compared to the results obtained from USEPA air quality index (AQI). According to the results from present study, fuzzy-based air quality index is a comprehensive tool for classification of air quality and tends to produce accurate results. Therefore, it can be considered useful, reliable, and suitable for consideration by local authorities in air quality assessment and management schemes. Fuzzy-based air quality index (FAQI).

  11. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P. J.; Gustafsson, U. R. C.

    1976-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of particulate and gaseous constituents of the atmosphere is collecting data on commercial air routes covering the world. Measurements are made in the upper troposphere and lower stratosphere (6 to 12 km) of constituents related to aircraft engine emissions and other pollutants. Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This unique system includes specialized instrumentation, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituent and related flight data are tape recorded in flight for later computer processing on the ground.

  12. A survey of airborne and skin exposures to chemicals in footwear and equipment factories in Thailand.

    PubMed

    Todd, Lori A; Mottus, Kathleen; Mihlan, Gary J

    2008-03-01

    This research reports on a pilot industrial hygiene study that was performed at four footwear factories and two equipment factories in Thailand. Workers in these factories were exposed through inhalation and dermal contact to a large number of organic vapors from solvents and cements that were hand applied. In addition, these workers were exposed to highly toxic isocyanates primarily through the dermal route. A total of 286 personal air samples were obtained at the four footwear factories using organic vapor monitors; individual job tasks were monitored using a real-time MIRAN Spectrometer. A total of 64 surface, tool, or hand samples were monitored for isocyanates using surface contamination detectors. Real-time measurements were also obtained for organic vapors in two equipment factories. From 8% to 21% of the workers sampled in each footwear factory were overexposed to mixtures of chemicals from solvents and cements. Up to 100% of the workers performing specific job tasks were overexposed to mixtures of chemicals. From 39% to 69% of the surface samples were positive for unreacted isocyanates. Many of the real-time measurements obtained in the equipment factories exceeded occupational exposure limits. Personal protective equipment and engineering controls were inadequate in all of the factories.

  13. Biases in Total Precipitable Water Vapor Climatologies from Atmospheric Infrared Sounder and Advanced Microwave Scanning Radiometer

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric J.; Lambrigtsen, Bjorn H.; Eldering, Annmarie; Aumann, Hartmut H.; Chahine, Moustafa T.

    2006-01-01

    We examine differences in total precipitable water vapor (PWV) from the Atmospheric Infrared Sounder (AIRS) and the Advanced Microwave Scanning Radiometer (AMSR-E) experiments sharing the Aqua spacecraft platform. Both systems provide estimates of PWV over water surfaces. We compare AIRS and AMSR-E PWV to constrain AIRS retrieval uncertainties as functions of AIRS retrieved infrared cloud fraction. PWV differences between the two instruments vary only weakly with infrared cloud fraction up to about 70%. Maps of AIRS-AMSR-E PWV differences vary with location and season. Observational biases, when both instruments observe identical scenes, are generally less than 5%. Exceptions are in cold air outbreaks where AIRS is biased moist by 10-20% or 10-60% (depending on retrieval processing) and at high latitudes in winter where AIRS is dry by 5-10%. Sampling biases, from different sampling characteristics of AIRS and AMSR-E, vary in sign and magnitude. AIRS sampling is dry by up to 30% in most high-latitude regions but moist by 5-15% in subtropical stratus cloud belts. Over the northwest Pacific, AIRS samples conditions more moist than AMSR-E by a much as 60%. We hypothesize that both wet and dry sampling biases are due to the effects of clouds on the AIRS retrieval methodology. The sign and magnitude of these biases depend upon the types of cloud present and on the relationship between clouds and PWV. These results for PWV imply that climatologies of height-resolved water vapor from AIRS must take into consideration local meteorological processes affecting AIRS sampling.

  14. Fabrication of prototype for measuring the exhaled breath temperature (EBT) to support detection of asthma

    NASA Astrophysics Data System (ADS)

    Harnawan, A. A.; Mariati; Fahrudin, A.; Assegaf, A.

    2017-05-01

    Recently, EBT has been proven as the marker of airways inflammation like asthma and proposed as the non-invasive tool. Although EBT device has already been made but this device is rarely used for patients in Indonesia. The aim of this study is to develop a prototype which accurately measures EBT and is comfortably used by patients including children. This prototype was made using SHT11 as a sensor of EBT which is integrated on a thermal flask 0.5L. This flask filled up patient breath and the temperature of air breath was measured. The EBT of twelve healthy samples and seven samples with asthma was examined using this prototype, the measurement was done within three minutes for all of them. The test results of EBT on healthy samples obtained the median is 33.9°C within of 33.0°C - 34.7°C and EBT on asthma samples obtained median is 35.0°C within the range 34.9°C - 36.0°C.

  15. Genetic Characterization of Atypical Enteropathogenic Escherichia coli Isolates from Ewes' Milk, Sheep Farm Environments, and Humans by Multilocus Sequence Typing and Pulsed-Field Gel Electrophoresis

    PubMed Central

    Otero, Verónica; Rodríguez-Calleja, José-María; Otero, Andrés; García-López, María-Luisa

    2013-01-01

    A collection of 81 isolates of enteropathogenic Escherichia coli (EPEC) was obtained from samples of bulk tank sheep milk (62 isolates), ovine feces (4 isolates), sheep farm environment (water, 4 isolates; air, 1 isolate), and human stool samples (9 isolates). The strains were considered atypical EPEC organisms, carrying the eae gene without harboring the pEAF plasmid. Multilocus sequence typing (MLST) was carried out with seven housekeeping genes and 19 sequence types (ST) were detected, with none of them having been previously reported for atypical EPEC. The most frequent ST included 41 strains isolated from milk and human stool samples. Genetic typing by pulsed-field gel electrophoresis (PFGE) resulted in 57 patterns which grouped in 24 clusters. Comparison of strains isolated from the different samples showed phylogenetic relationships between milk and human isolates and also between milk and water isolates. The results obtained show a possible risk for humans due to the presence of atypical EPEC in ewes' milk and suggest a transmission route for this emerging pathogen through contaminated water. PMID:23872571

  16. Spectrometric Analysis for Pulse Jet Mixer Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ZEIGLER, KRISTINE

    2004-07-12

    The Analytical Development Section (ADS) was tasked with providing support for a Hanford River Protection Program-Waste Treatment Program (RPP-WTP) project test involving absorption analysis for non-Newtonian pulse jet mixer testing for small scale (PJM) and prototype (CRV) tanks with sparging. Tanks filled with clay were mixed with various amounts of powdered dye as a tracer. The objective of the entire project was to determine the best mixing protocol (nozzle velocity, number of spargers used, total air flow, etc.) by determining the percent mixed volume through the use of an ultraviolet-visible (UV-Vis) spectrometer. The dye concentration within the sample could bemore » correlated to the volume fraction mixed in the tank. Samples were received in vials, a series of dilutions were generated from the clay, allowed to equilibrate, then centrifuged and siphoned for the supernate liquid to analyze by absorption spectroscopy. Equilibration of the samples and thorough mixing of the samples were a continuous issue with dilution curves being difficult to obtain. Despite these technical issues, useful data was obtained for evaluation of various mix conditions.« less

  17. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...

  18. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...

  19. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...

  20. The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.

    PubMed

    Strawsine, Ellen; Lutmer, Brian

    2017-11-16

    This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.

  1. 40 CFR 49.131 - General rule for open burning.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... must notify any appropriate Tribal air pollution authority and obtain any permissions or approvals... any appropriate Tribal air pollution authority and obtain any permissions or approvals required by the... prohibited whenever the Regional Administrator issues an air stagnation advisory or declares an air pollution...

  2. [Chemical hazards when working with solvent glues].

    PubMed

    Domański, Wojciech; Makles, Zbigniew

    2012-01-01

    Solvent glues are used in a wide variety of industries, e.g., textile, footwear and rubber. The problem of workers' exposure to solvent vapors is rarely tackled within the area of occupational safety and health in small and medium-sized enterprises. In order to assess exposure to solvents, organic solvents emitted by glues were identified in the samples of workplace air. The concentration of acetone, benzene, cyclohexane, ethylbenzene, n-hexane, methylcyclohexane, butyl acetate and toluene were determined. The obtained results evidenced the presence of cyclohexane, ethylbenzene, ethylcyclohexane, heptane, n-hexane, o-xylene, methylcyclohexane, methylcyclopentane, butyl acetate and toluene in workplace air. The concentration of those compounds in workplace air was low, usually below 0.15 of MAC. At some workstations the presence of benzene was also observed. Occupational risk was assessed at workstations where gluing took place. It showed that the risk at those workstations was medium or low.

  3. Sea surface temperature anomalies, planetary waves, and air-sea feedback in the middle latitudes

    NASA Technical Reports Server (NTRS)

    Frankignoul, C.

    1985-01-01

    Current analytical models for large-scale air-sea interactions in the middle latitudes are reviewed in terms of known sea-surface temperature (SST) anomalies. The scales and strength of different atmospheric forcing mechanisms are discussed, along with the damping and feedback processes controlling the evolution of the SST. Difficulties with effective SST modeling are described in terms of the techniques and results of case studies, numerical simulations of mixed-layer variability and statistical modeling. The relationship between SST and diabatic heating anomalies is considered and a linear model is developed for the response of the stationary atmosphere to the air-sea feedback. The results obtained with linear wave models are compared with the linear model results. Finally, sample data are presented from experiments with general circulation models into which specific SST anomaly data for the middle latitudes were introduced.

  4. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air...

  5. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air...

  6. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 30, 2015 – December 6, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  7. Carter Carburetor Weekly Air Monitoring & Sampling Report - October 26, 2015 – November 1, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  8. Carter Carburetor Weekly Air Monitoring & Sampling Report - February 15, 2016 – February 21, 2016

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  9. Carter Carburetor Weekly Air Monitoring & Sampling Report - October 12, 2015 – October 18, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  10. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 23, 2015 – November 29, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  11. Carter Carburetor Weekly Air Monitoring & Sampling Report - October 5, 2015 – October 11, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  12. Carter Carburetor Weekly Air Monitoring & Sampling Report - February 1, 2016 – February 7, 2016

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  13. Carter Carburetor Weekly Air Monitoring & Sampling Report - September 28, 2015 – October 4, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  14. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 16, 2015 – November 22, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  15. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 9, 2015 – November 15, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  16. Carter Carburetor Weekly Air Monitoring & Sampling Report - October 19, 2015 – October 25, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  17. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 2, 2015 – November 8, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  18. Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.

    PubMed

    Witschger, O; Grinshpun, S A; Fauvel, S; Basso, G

    2004-06-01

    While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the dust source, faces the source. Thus, the first objective of this study was to design and test a new, low cost experimental protocol for measuring the sampling efficiency of personal inhalable aerosol samplers in the vicinity of the aerosol source when the samplers operate in very slowly moving air. In this system, an aerosol generator, which is located in the centre of a room-sized non-ventilated chamber, continuously rotates and omnidirectionally disperses test particles of a specific size. The test and reference samplers are equally distributed around the source at the same distance from the centre and operate in parallel (in most of our experiments, the total number of simultaneously operating samplers was 15). Radial aerosol transport is driven by turbulent diffusion and some natural convection. For each specific particle size and the sampler, the aerosol mass concentration is measured by weighing the collection filter. The second objective was to utilize the new protocol to evaluate three widely used aerosol samplers: the IOM Personal Inhalable Sampler, the Button Personal Inhalable Aerosol Sampler and the 25 mm Millipore filter holder (closed-face C25 cassette). The sampling efficiencies of each instrument were measured with six particle fractions, ranging from 6.9 to 76.9 micro m in their mass median aerodynamic diameter. The Button Sampler efficiency data demonstrated a good agreement with the standard inhalable convention and especially with the low air movement inhalabilty curve. The 25 mm filter holder was found to considerably under-sample the particles larger than 10 micro m; its efficiency did not exceed 7% for particles of 40-100 micro m. The IOM Sampler facing the source was found to over-sample compared with the data obtained previously with a slowly rotating, freely suspended sampler in a low air movement environment. It was also found that the particle wall deposition in the IOM metallic cartridge was rather significant and particle size-dependent. For each sampler (IOM, Button and C25) the precision was characterized through the relative standard deviation (RSD) of the aerosol concentration obtained with identical samplers in a specific experiment. The average RSD was 14% for the IOM Sampler, 11% for the Button Sampler and 35% for the 25 mm filter cassette. A separate set of experiments, performed with the Simplified Torso showed that in very slowly moving air a personal sampler can be adequately evaluated even when it is not attached to a body but freely suspended (confirming the data reported previously).

  19. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...

  20. Detection of influenza A virus in aerosols of vaccinated and non-vaccinated pigs in a warm environment.

    PubMed

    Neira, Victor; Allerson, Matt; Corzo, Cesar; Culhane, Marie; Rendahl, Aaron; Torremorell, Montserrat

    2018-01-01

    The 2009 influenza pandemic, the variant H3N2v viruses in agricultural fairs and the zoonotic poultry H5N9 infections in China have highlighted the constant threat that influenza A viruses (IAV) present to people and animals. In this study we evaluated the effect of IAV vaccination on aerosol shedding in pigs housed in warm environmental conditions. Thirty-six, three-week old weaned pigs were obtained from an IAV negative herd and were randomly allocated to one of 4 groups: 1) a homologous vaccine group, 2) a heterologous multivalent vaccine group, 3) a heterologous monovalent group and, 4) a non-vaccinated group. After vaccination pigs were challenged with the triple reassortant A/Sw/IA/00239/04 H1N1 virus. Environmental temperature and relative humidity were recorded throughout the study. Nasal swabs, oral fluids and air samples were collected daily. All samples were tested by RRT-PCR and virus isolation was attempted on positive samples. Average temperature and relative humidity throughout the study were 27°C (80°F) and 53%, respectively. A significantly higher proportion of infected pigs was detected in the non-vaccinated than in the vaccinated group. Lower levels of nasal virus shedding were found in vaccinated groups compared to non-vaccinated group and IAV was not detected in air samples of any of the vaccinated groups. In contrast, positive air samples were detected in the non-vaccinated group at 1, 2 and 3 days post infection although the overall levels were considered low most likely due to the elevated environmental temperature. In conclusion, both the decrease in shedding and the increase in environmental temperature may have contributed to the inability to detect airborne IAV in vaccinated pigs.

  1. Analysis of EPA and DOE WIPP Air Sampling Data

    EPA Pesticide Factsheets

    During the April 2014 EPA visit to WIPP, EPA co-located four ambient air samplers with existing Department of Energy (DOE) ambient air samplers to independently corroborate DOE's reported air sampling results.

  2. Air and surface contamination patterns of meticillin-resistant Staphylococcus aureus on eight acute hospital wards.

    PubMed

    Creamer, E; Shore, A C; Deasy, E C; Galvin, S; Dolan, A; Walley, N; McHugh, S; Fitzgerald-Hughes, D; Sullivan, D J; Cunney, R; Coleman, D C; Humphreys, H

    2014-03-01

    Meticillin-resistant Staphylococcus aureus (MRSA) can be recovered from hospital air and from environmental surfaces. This poses a potential risk of transmission to patients. To investigate associations between MRSA isolates recovered from air and environmental surfaces with those from patients when undertaking extensive patient and environmental sampling. This was a prospective observational study of patients and their environment in eight wards of a 700-bed tertiary care hospital during 2010 and 2011. Sampling of patients, air and surfaces was carried out on all ward bays, with more extended environmental sampling in ward high-dependency bays and at particular times of the day. The genetic relatedness of isolates was determined by DNA microarray profiling and spa typing. MRSA was recovered from 30/706 (4.3%) patients and from 19/132 (14.4%) air samples. On 9/132 (6.8%) occasions both patient and air samples yielded MRSA. In 32 high-dependency bays, MRSA was recovered from 12/161 (7.4%) patients, 8/32 (25%) air samples, and 21/644 (3.3%) environmental surface samples. On 10/132 (7.6%) occasions, MRSA was isolated from air in the absence of MRSA-positive patients. Patient demographic data combined with spa typing and DNA microarray profiling revealed four likely transmission clusters, where patient and environmental isolates were deemed to be very closely related. Air sampling yielded MRSA on frequent occasions, especially in high-dependency bays. Environmental and air sampling combined with patient demographic data, spa typing and DNA microarray profiling indicated the presence of clusters that were not otherwise apparent. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Size distribution and clothing-air partitioning of polycyclic aromatic hydrocarbons generated by barbecue.

    PubMed

    Lao, Jia-Yong; Wu, Chen-Chou; Bao, Lian-Jun; Liu, Liang-Ying; Shi, Lei; Zeng, Eddy Y

    2018-10-15

    Barbecue (BBQ) is one of the most popular cooking activities with charcoal worldwide and produces abundant polycyclic aromatic hydrocarbons (PAHs) and particulate matter. Size distribution and clothing-air partitioning of particle-bound PAHs are significant for assessing potential health hazards to humans due to exposure to BBQ fumes, but have not been examined adequately. To address this issue, particle and gaseous samples were collected at 2-m and 10-m distances from a cluster of four BBQ stoves. Personal samplers and cotton clothes were carried by volunteers sitting near the BBQ stoves. Particle-bound PAHs (especially 4-6 rings) derived from BBQ fumes were mostly affiliated with fine particles in the size range of 0.18-1.8 μm. High molecular-weight PAHs were mostly unimodal peaking in fine particles and consequently had small geometric mean diameters and standard deviations. Source diagnostics indicated that particle-bound PAHs in BBQ fumes were generated primarily by combustion of charcoal, fat content in food, and oil. The influences of BBQ fumes on the occurrence of particle-bound PAHs decreased with increasing distance from BBQ stoves, due to increased impacts of ambient sources, especially by petrogenic sources and to a lesser extent by wind speed and direction. Octanol-air and clothing-air partition coefficients of PAHs obtained from personal air samples were significantly correlated to each other. High molecular-weight PAHs had higher area-normalized clothing-air partition coefficients in cotton clothes, i.e., cotton fabrics may be a significant reservoir of higher molecular-weight PAHs. Particle-bound PAHs from barbecue fumes are generated largely from charcoal combustion and food-charred emissions and mainly affiliated with fine particles. Copyright © 2018. Published by Elsevier B.V.

  4. 40 CFR 49.131 - General rule for open burning.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., the fire protection service must notify any appropriate Tribal air pollution authority and obtain any... operator must notify any appropriate Tribal air pollution authority and obtain any permissions or approvals... prohibited whenever the Regional Administrator issues an air stagnation advisory or declares an air pollution...

  5. Shelf-life extension of refrigerated Mediterranean mullet (Mullus surmuletus) using modified atmosphere packaging.

    PubMed

    Pournis, Nikolaos; Papavergou, Aikaterini; Badeka, Anastasia; Kontominas, Michael G; Savvaidis, Ioannis N

    2005-10-01

    The present work evaluated the quality and freshness characteristics and the effect of modified atmosphere packaging (MAP) on the shelf-life extension of refrigerated Mediterranean mullet using microbiological, biochemical, and sensory analyses. Fresh open sea red mullet (Mullus surmuletus) were packaged in four different atmospheres: M1, 10%/20%/70% (O2/ CO2/N2); M2, 10%/40%/50% (O2/CO2/N2); M3, 10%/60%/30% (O2/CO2/N2); identical fish samples were packaged in air. All fish were kept under refrigeration (4 +/- 0.5 degrees C) for 14 days. Of the three gas atmospheres, the 10%/40%/50% (M2) and 10%/ 60%/30% (M3) gas mixtures were the most effective for inhibiting growth of aerobic microflora in mullet samples until day 10 of refrigerated storage. H2S-producing bacteria and pseudomonads were part of the mullet microflora and their growth was partly inhibited under MAP conditions. Between these two bacterial groups, H2S-producing bacteria (including Shewanella putrefaciens) were dominant toward the end of the storage period, regardless of the packaging conditions. Brochothrix thermosphacta and lactic acid bacteria were found to be members of the final microbial flora of MAP and air-packaged mullet, whereas the Enterobacteriaceae population was lower than other bacterial groups. Of the chemical freshness indices determined, thiobarbituric acid values were variable in mullet samples irrespective of packaging conditions indicative of no specific oxidative rancidity trend. Based on sensorial data and aerobic plate count, trimethylamine nitrogen and total volatile basic nitrogen limit values in the range of ca. 15 to 23 and 52 to 60 mg N/100 g of fish muscle were obtained, respectively, for mullet packaged under modified atmosphere and air. Sensory analyses (odor and taste attributes) showed that the limit of sensorial acceptability was reached after ca. 6 days for the samples packaged in air, 8 days for the M1 and M3 samples, and after 10 days for the M2 samples. Respective shelf-life extension for fresh whole mullet was ca. 2 days (M1 and M3 gas mixtures), and 4 days (M2 gas mixture).

  6. The molecular characteristics of avian influenza viruses (H9N2) derived from air samples in live poultry markets.

    PubMed

    Wu, Yanheng; Lin, Jinsi; Yang, Shuhuan; Xie, Ying; Wang, Man; Chen, Xueqin; Zhu, Yayang; Luo, Le; Shi, Wuyang

    2018-06-01

    To study the molecular characteristics of H9N2-subtype avian influenza viruses (AIVs) isolated from air samples collected in live poultry markets (LPMs) and explore their sequence identities with AIVs that caused human infection. Weekly surveillance of H9N2-subtype AIVs in the air of LPMs was conducted from 2015 to 2016. H9-positive samples were isolated from chicken embryos. Whole genome sequences of the isolated AIVs were obtained through high-throughput sequencing. Phylogenetic analysis and key loci variations of the sequences were further analyzed. A total of 327 aerosol samples were collected from LPMs. Nine samples were positive for H9-subtype AIVs based on quantitative real-time reverse transcription polymerase chain reaction (qRRT-PCR). According to the whole genome sequence analysis and phylogenetic analysis, except for the A/Environment/Zhongshan/ZS201505/2015 (ZS201505) strain, 8 gene segments of 8 aerosol H9N2 isolates and 2 H9N2 human isolates in 2015 were located in the same clade. Among key loci variations, except for the ZS201505 strain, H9N2-subtype AIVs had no mutations in eight receptor binding sites of hemagglutinin (HA), and stalks of neuraminidase (NA) proteins exhibited a deletion site of three bases. The PA gene of ZS201503 and ZS201602 exhibited an L336M mutation. The N30D and T215A mutations in the M1 gene and amino acid residues L89V in PB2, P42S in NS1 and S31N in M2 were retained in these 9 strains of H9N2 isolates, which could enhance the virus's virulence. Live H9N2 AIVs survived in the aerosol of LPMs in Zhongshan City. The aerosol viruses had a close evolutionary relationship with human epidemic strains, indicating that there might be a risk of AIV transmission from polluted aerosols in LPMs to humans. Mutations in H9N2-subtype AIVs isolated from air samples collected from LPMs suggested their pathogenicity was enhanced to infect humans. Copyright © 2018. Published by Elsevier B.V.

  7. NASA 9-Point LDI Code Validation Experiment

    NASA Technical Reports Server (NTRS)

    Hicks, Yolanda R.; Anderson, Robert C.; Locke, Randy J.

    2007-01-01

    This presentation highlights the experimental work to date to obtain validation data using a 9-point lean direct injector (LDI) in support of the National Combustion Code. The LDI is designed to supply fuel lean, Jet-A and air directly into the combustor such that the liquid fuel atomizes and mixes rapidly to produce short flame zones and produce low levels of oxides of nitrogen and CO. We present NOx and CO emission results from gas sample data that support that aspect of the design concept. We describe this injector and show high speed movies of selected operating points. We present image-based species maps of OH, fuel, CH and NO obtained using planar laser induced fluorescence and chemiluminescence. We also present preliminary 2-component, axial and vertical, velocity vectors of the air flow obtained using particle image velocimetry and of the fuel drops in a combusting case. For the same combusting case, we show preliminary 3-component velocity vectors obtained using a phase Doppler anemometer. For the fueled, combusting cases especially, we found optical density is a technical concern that must be addressed, but that in general, these preliminary results are promising. All optical-based results confirm that this injector produces short flames, typically on the order of 5- to-7-mm long at typical cruise and high power engine cycle conditions.

  8. ASSESSMENT OF THE INDOOR ENVIRONMENT AND IMPLICATIONS FOR HEALTH IN ROMA VILLAGES IN SLOVAKIA AND ROMANIA

    PubMed Central

    Majdan, Marek; Coman, Alexandru; Gallová, Eva; Ďuricová, Janka; Kállayová, Daniela; Kvaková, Mária; Bošák, Ľuboš

    2013-01-01

    SUMMARY Objectives The objective of this paper is to provide information on indoor air quality and on the quality of the broader indoor environment of the houses in Roma villages in Slovakia and Romania and to discuss possible implications for health. Methods Indoor air was sampled in 11 houses in a Romanian Roma village and in 19 houses in a Slovakian Roma village. Levels of Carbon Monoxide (CO), Carbon Dioxide (CO2), total particulate matter (PM), temperature and humidity were measured. A questionnaire and a checklist were used to obtain additional information on the indoor environment and behavioural factors. We have sampled the same houses in winter and in summer. Results Levels of CO and CO2 were higher in winter in both countries as compared to summer. The limit value of 10 mg/m3 CO was exceeded in a few cases in both countries. In general, levels of CO, CO2 and PM were higher in Romania. Further environmental and behavioural hazards such as indoor smoking, pets inside or lack of ventilation were found. The reported self-perceived quality of the indoor environment was poor in many aspects. Conclusions Our findings of CO, CO2 and PM levels suggest that indoor air pollution in Roma settlements has the potential to be a health threat. The fact that the inhabitants spend a relatively long time inside the houses and that a number of additional environmental and behavioural hazards were identified by our study emphasizes the importance of the indoor air quality for health and thus priority attention should be paid to these issues by health authorities and researchers. Further research is essential and study designs must consider cultural background and specific characteristics of the community, especially in order to obtain valid data on health outcomes. PMID:23285520

  9. Microbial air quality in mass transport buses and work-related illness among bus drivers of Bangkok Mass Transit Authority.

    PubMed

    Luksamijarulkul, Pipat; Sundhiyodhin, Viboonsri; Luksamijarulkul, Soavalug; Kaewboonchoo, Orawan

    2004-06-01

    The air quality in mass transport buses, especially air-conditioned buses may affect bus drivers who work full time. Bus numbers 16, 63, 67 and 166 of the Seventh Bus Zone of Bangkok Mass Transit Authority were randomly selected to investigate for microbial air quality. Nine air-conditioned buses and 2-4 open-air buses for each number of the bus (36 air-conditioned buses and 12 open-air buses) were included. Five points of in-bus air samples in each studied bus were collected by using the Millipore A ir Tester Totally, 180 and 60 air samples collected from air-conditioned buses and open-air buses were cultured for bacterial and fungal counts. The bus drivers who drove the studied buses were interviewed towards histories of work-related illness while working. The results revealed that the mean +/- SD of bacterial counts in the studied open-air buses ranged from 358.50 +/- 146.66 CFU/m3 to 506 +/- 137.62 CFU/m3; bus number 16 had the highest level. As well as the mean +/- SD of fungal counts which ranged from 93.33 +/- 44.83 CFU/m3 to 302 +/- 294.65 CFU/m3; bus number 166 had the highest level. Whereas, the mean +/- SD of bacterial counts in the studied air-conditioned buses ranged from 115.24 +/- 136.01 CFU/m3 to 244.69 +/- 234.85 CFU/m3; bus numbers 16 and 67 had the highest level. As well as the mean +/- SD of fungal counts which rangedfrom 18.84 +/- 39.42 CFU/m3 to 96.13 +/- 234.76 CFU/m3; bus number 166 had the highest level. When 180 and 60 studied air samples were analyzed in detail, it was found that 33.33% of the air samples from open-air buses and 6.11% of air samples from air-conditioned buses had a high level of bacterial counts (> 500 CFU/m3) while 6.67% of air samples from open-air buses and 2.78% of air samples from air-conditioned buses had a high level of fungal counts (> 500 CFU/m3). Data from the history of work-related illnesses among the studied bus drivers showed that 91.67% of open-air bus drivers and 57.28% of air-conditioned bus drivers had symptoms of work-related illnesses, p = 0.0185.

  10. Corrosion resistance and biological activity of TiO2 implant coatings produced in oxygen-rich environments.

    PubMed

    Zhang, Rui; Wan, Yi; Ai, Xing; Liu, Zhanqiang; Zhang, Dong

    2017-01-01

    The physical and chemical properties of bio-titanium alloy implant surfaces play an important role in their corrosion resistance and biological activity. New turning and turning-rolling processes are presented, employing an oxygen-rich environment in order to obtain titanium dioxide layers that can both protect implants from corrosion and also promote cell adhesion. The surface topographies, surface roughnesses and chemical compositions of the sample surfaces were obtained using scanning electron microscopy, a white light interferometer, and the Auger electron spectroscopy, respectively. The corrosion resistance of the samples in a simulated body fluid was determined using electrochemical testing. Biological activity on the samples was also analyzed, using a vitro cell culture system. The results show that compared with titanium oxide layers formed using a turning process in air, the thickness of the titanium oxide layers formed using turning and turning-rolling processes in an oxygen-rich environment increased by 4.6 and 7.3 times, respectively. Using an oxygen-rich atmosphere in the rolling process greatly improves the corrosion resistance of the resulting samples in a simulated body fluid. On samples produced using the turning-rolling process, cells spread quickly and exhibited the best adhesion characteristics.

  11. Aerosol sampling system for collection of Capstone depleted uranium particles in a high-energy environment.

    PubMed

    Holmes, Thomas D; Guilmette, Raymond A; Cheng, Yung Sung; Parkhurst, Mary Ann; Hoover, Mark D

    2009-03-01

    The Capstone Depleted Uranium (DU) Aerosol Study was undertaken to obtain aerosol samples resulting from a large-caliber DU penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post perforation, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the crew locations in the test vehicles. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for measurement of chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for DU concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.

  12. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung

    2009-03-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used tomore » achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol.« less

  13. Study of spatiotemporal variation of atmospheric mercury and its human exposure around an integrated steel plant, India

    NASA Astrophysics Data System (ADS)

    Pervez, S.; Koshle, A.; Pervez, Y.

    2010-01-01

    Mercury release by coal combustion has been significantly increased in India. Mercury content in coal has been analyzed to 0.272 ppm by Central Pollution Control Board. Toxicological effects of elemental Hg (Hg0) exposure include respiratory and renal failures, cardiac arrest, and cerebral oedema, while subclinical exposure may induce kidney, behavioral, and cognitive dysfunctions. The present work is focused on dispersion pattern and inter-phase exchange phenomena of ambient mercury between air-particulate matter evaluations of alongwith dominance of various major routes of human exposure-dose response using regression analysis around an integrated steel plant in central India. Source-downwind type stratified random sampling plan using longitudinal study design has been adopted for ambient monitoring of total mercury, while representative sampling plant has been adopted for persona exposure-dose response study In space-time framework. Control sites and subjects have been chosen from uncontaminated area (100 km away from any industrial activities). 06 ambient air monitoring stations and 17 subjects from workers, non-workers but local residents' categories and from controlled sites have been chosen for the study. Samples of mercury biomarkers (blood, breast milk and urine) have also been collected from same subjects in each month during sampling period. The sampling period was March 2005 to February 2006 . Samples of 30% acidified KMnO4 for air-Hg absorption, PM10, RPM and biological samples were analyzed for total mercury by ICP-AES using standard methods. Local soils and ground water were also monitored for total mercury content during the sampling period. Results have shown that mercury concentration is very high compared to prescribed limits in all receptors. Results of exchange phenomenon have shown the higher transfer of mercury from air to particulate during combustion in steel plant environment due to presence of huge amount of iron particles, in contrast to results obtained in other industrial locations earlier. Plant workers have shown 1.5 to 2.5 times higher personal RPM-Hg levels compared to Category 2 and 20-30 times higher than Category 3. All biomarkers have shown higher Hg presence compared to prescribed standards. Regression analysis between exposure routes and bio-receptors has been investigated. Dominance status of selected routes of bio-accumulation has been varied from category to category.

  14. Study of spatiotemporal variation of atmospheric mercury and its human exposure around an integrated steel plant, India

    NASA Astrophysics Data System (ADS)

    Pervez, S.; Koshle, A.; Pervez, Y.

    2010-06-01

    Mercury release by coal combustion has been significantly increased in India. Mercury content in coal has been analyzed to 0.272 ppm by Central Pollution Control Board. Toxicological effects of elemental Hg (Hg0) exposure include respiratory and renal failures, cardiac arrest, and cerebral oedema, while subclinical exposure may induce kidney, behavioral, and cognitive dysfunctions. The present work is focused on dispersion pattern and inter-phase exchange phenomena of ambient mercury between air-particulate matter evaluations of alongwith dominance of various major routes of human exposure-dose response using regression analysis around an integrated steel plant in central India. Source-downwind type stratified random sampling plan using longitudinal study design has been adopted for ambient monitoring of total mercury, while representative sampling plant has been adopted for persona exposure-dose response study In space-time framework. Control sites and subjects have been chosen from uncontaminated area (100 km away from any industrial activities). 06 ambient air monitoring stations and 17 subjects from workers, non-workers but local residents' categories and from controlled sites have been chosen for the study. Samples of mercury biomarkers (blood, breast milk and urine) have also been collected from same subjects in each month during sampling period. The sampling period was March 2005 to February 2006 . Samples of 30% acidified KMnO4 for air-Hg absorption, PM10, RPM and biological samples were analyzed for total mercury by ICP-AES using standard methods. Local soils and ground water were also monitored for total mercury content during the sampling period. Results have shown that mercury concentration is very high compared to prescribed limits in all receptors. Results of exchange phenomenon have shown the higher transfer of mercury from air to particulate during combustion in steel plant environment due to presence of huge amount of iron particles, in contrast to results obtained in other industrial locations earlier. Plant workers have shown 1.5 to 2.5 times higher personal RPM-Hg levels compared to Category 2 and 20-30 times higher than Category 3. All biomarkers have shown higher Hg presence compared to prescribed standards. Regression analysis between exposure routes and bio-receptors has been investigated. Dominance status of selected routes of bio-accumulation has been varied from category to category.

  15. Development of a 100 nmol mol(-1) propane-in-air SRM for automobile-exhaust testing for new low-emission requirements.

    PubMed

    Rhoderick, George C

    2007-04-01

    New US federal low-level automobile emission requirements, for example zero-level-emission vehicle (ZLEV), for hydrocarbons and other species, have resulted in the need by manufacturers for new certified reference materials. The new emission requirement for hydrocarbons requires the use, by automobile manufacturing testing facilities, of a 100 nmol mol(-1) propane in air gas standard. Emission-measurement instruments are required, by federal law, to be calibrated with National Institute of Standards and Technology (NIST) traceable reference materials. Because a NIST standard reference material (SRM) containing 100 nmol mol(-1) propane was not available, the US Environmental Protection Agency (EPA) and the Automobile Industry/Government Emissions Research Consortium (AIGER) requested that NIST develop such an SRM. A cylinder lot of 30 gas mixtures containing 100 nmol mol(-1) propane in air was prepared in 6-L aluminium gas cylinders by a specialty gas company and delivered to the Gas Metrology Group at NIST. Another mixture, contained in a 30-L aluminium cylinder and included in the lot, was used as a lot standard (LS). Using gas chromatography with flame-ionization detection all 30 samples were compared to the LS to obtain the average of six peak-area ratios to the LS for each sample with standard deviations of <0.31%. The average sample-to-LS ratio determinations resulted in a range of 0.9828 to 0.9888, a spread of 0.0060, which corresponds to a relative standard deviation of 0.15% of the average for all 30 samples. NIST developed its first set of five propane in air primary gravimetric standards covering a concentration range 91 to 103 nmol mol(-1) with relative uncertainties of 0.15%. This new suite of propane gravimetric standards was used to analyze and assign a concentration value to the SRM LS. On the basis of these data each SRM sample was individually certified, furnishing the desired relative expanded uncertainty of +/-0.5%. Because automobile companies use total hydrocarbons to make their measurements, it was also vital to assign a methane concentration to the SRM samples. Some of the SRM samples were analyzed and found to contain 1.2 nmol mol(-1) methane. Twenty-five of the samples were certified and released as SRM 2765.

  16. A new technique for preliminary estimates of TRU activity on air sample filters and radiological smears.

    PubMed

    Hayes, Robert

    2004-10-01

    In most nuclear facilities, fixed air samplers and sometimes portable air samplers are used where some probability of a release exists but is not expected, and so the added expense and effort of using a continuous air monitor is not deemed justified. When a release is suspected, naturally occurring radioactive material buildup on the filter typically prevents any quantitative measurements within the first day or so. Likewise, outdoor air measurements suffer from the same limitations (such as those taken during the Los Alamos fires) and so any rapid quantifiable measurements of fixed air sampler/portable air sampler filters which are technically defendable (even though conservative) are of use. The technique presented here is only intended for use in routine health physics survey applications and does not presently appear to be appropriate for sub pico Curie activity determinations. This study evaluates the utility of using a portable continuous air monitor as an alpha spectrometer to make transuranic activity determinations of samples using both the built in algorithm for air monitoring and a simple region of interest analysis. All samples evaluated were from air sample filters taken using a portable air sampler. Samples were taken over many months to quantify effects from natural variation in radon progeny activity distributions.

  17. Early-life exposure to air pollutants and adverse pregnancy outcomes: protocol for a prospective cohort study in Beijing.

    PubMed

    Song, Jing; Chen, Yi; Wei, Ling; Ma, Ying; Tian, Ning; Huang, Shi Yun; Dai, Yin Mei; Zhao, Li Hong; Kong, Yuan Yuan

    2017-09-03

    The association between early exposure to ambient air pollution and adverse pregnancy outcomes in China is unclear. This study will assess the risk of early-life exposure to air pollutants in Beijing and explore the viability of 8-hydroxydeoxyguanosine (8-OHdG) as a biological indicator to assess oxidative stress induced by early-life exposure to air pollution. Here , 2500 women with singleton pregnancies and their infants will be recruited from the Beijing Obstetrics and Gynecology Hospital. We will collect nine types of biological samples, including maternal serum, urine, placental tissue, umbilical cord tissue and umbilical cord blood during all three trimesters. The air pollution data (particulate matter (PM)2.5, PM10 and similar factors) will be recorded at official fixed-site monitoring stations closest to where the pregnant women live. We plan to assess the effect of air pollutants on adverse pregnancy outcomes and infant respiratory and circulatory disease using Cox regression and competitive risk analysis and explore possible critical windows of exposure during pregnancy using daily pollutant concentrations averaged over various periods of pregnancy combined with individual activity and physiological parameters. Maternal and umbilical cord blood samples (1000 samples) will be randomly selected for 8-OHdG assays to assess the correlation between exposures to air pollutants and oxidative stress. We will determine whether air pollutant exposure or 8-OHdG levels are associated with adverse pregnancy outcomes. SPSS and SAS statistical software will be used for data analysis. Cox regression and competing risk analysis will be used to compute the HR and population attributable risk. This research protocol has already been approved by the Medical Ethics Committee of Beijing Obstetrics and Gynecology Hospital. Written informed consent will be obtained from all study participants prior to enrolment. The results will be published in peer-reviewed journals or disseminated through conference presentations. This study has been registered in WHO International Clinical Trial Register-Chinese Clinical Trial Registry under registrationnumber ChiCTR-ROC-16010181 (http :// www.chictr.org.cn / showproj.aspx ?proj=17328). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Baseline Studies of Selected Polybrominated Diphenyl Ethers in the Air of the Nandamojo Watershed, Costa Rica

    NASA Astrophysics Data System (ADS)

    Geesey, Mary Sophia

    Polybrominated diphenyl ethers (PBDEs) have been used as flame retardants in a number of common household and commercial products around the world. PBDEs enter the environment in a variety of ways, such as through emissions, leaching from end-of-life electronics in landfills, and incineration. While many countries have phased out the manufacturing of penta-, octa-, and deca-PBDEs or have banned the manufacture and use of these congeners altogether, these persistent organic pollutants (POPs) continue to be detected in humans and the environment. This study investigates spatial and temporal variations of selected PBDEs in the air of the Nandamojo watershed area in Costa Rica by comparing air concentrations of PBDEs in the dry winter vs. wet summer seasons and rural vs. urban areas and also investigates the impact of anthropogenic activities on air concentration of PBDEs. This study is significant to the field, because there are no baseline studies nor are there currently any monitoring programs to assess the environmental levels of PBDEs or other POPs for this region of the Guanacaste province. Baseline information is needed to track spatial and temporal trends as well as evaluate the effectiveness of control measures employed nationally and internationally. Samples obtained from passive air sampling devices were analyzed via GC/MS for a number of congeners. PBDE-47 and -99 were found to be the congeners present in greatest concentration in air samples from the Nandamojo watershed area. Air concentrations were estimated assuming an average sampler uptake rate of 3.5 m3/day and ranged as follows: SigmaPBDE5 35.20-1549.25 pg/m3 over the entire study. The presence of PBDEs in remote and pristine environments indicates that PBDEs are now a global concern. This study suggests that the spatial and temporal distribution patterns observed are strongly related to anthropogenic activities and presence of a population similar to that observed in other studies. The presence of PBDEs has become a global issue and, as such, these results provide background information on air concentrations of PBDEs for use in a global-scale multimedia model. In order to monitor PBDEs globally, it is imperative to implement and/or expand surveillance programs internationally.

  19. Resonant photoacoustic detection of NO2 traces with a Q-switched green laser

    NASA Astrophysics Data System (ADS)

    Slezak, Verónica; Codnia, Jorge; Peuriot, Alejandro L.; Santiago, Guillermo

    2003-01-01

    Resonant photoacoustic detection of NO2 traces by means of a high repetition pulsed green laser is presented. The resonator is a cylindrical Pyrex glass cell with a measured Q factor 380 for the first radial mode in air at atmospheric pressure. The system is calibrated with known mixtures in dry air and a minimum detectable volume concentration of 50 parts in 109 is obtained (S/N=1). Its sensitivity allows one to detect and quantify NO2 traces in the exhaust gases of cars. Previously, the analysis of gas adsorption and desorption on the walls and of changes in the sample composition is carried out in order to minimize errors in the determination of NO2 content upon application of the extractive method. The efficiency of catalytic converters of several models of automobiles is studied and the NO2 concentration in samples from exhausts of different types of engine (gasoline, diesel, and methane gas) at idling operation are measured.

  20. [Performance evaluation of Rapid™ Yeast Plus (Remel) system from two different culture media].

    PubMed

    Romeo, Ana M; Snitman, Gabriela V; Marucco, Andrea P; Ponce, Graciela Del V; Cataldi, Silvana P; Guelfand, Liliana I; Arechavala, Alicia

    Within the genus Candida, Candida albicans is the most commonly isolated species from clinical samples. Due to the emergence of other species which can show a higher index of antifungal resistance, a fast identification of these species is necessary. The aim of this work was to evaluate the performance of the RapID Yeast Plus system from two different subculture media formulations: Sabouraud dextrose agar adjusted by Emmons (the medium is indicated in the equipment insert) and Sabouraud glucose agar, which is the most frequently used in Buenos Aires City laboratories. One hundred and sixty-six clinical sample strains coming from different hospitals belonging to the Mycology Network of Buenos Aires City were studied. From the obtained results, we conclude that the conditions and culture medium indicated by the manufacturer should be followed. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Trace gas measurements from tethered balloon platforms

    NASA Technical Reports Server (NTRS)

    Bandy, Alan R.; Bandy, Terese L.; Youngbluth, Otto; Owens, Thomas L.

    1987-01-01

    Instrumentation and chemical sampling and analysis procedures are described for making measurements of atmospheric carbon disulfide in the concentration range 1-1000 pptv from tethered balloon platforms. Results of a study on the CS2 composition of air downward of a saltwater marsh are reported. A method for obtaining the necessary data for solving the budget equations for surface fluxes, chemical formation rates and chemical destruction rates using data acquired from tethered balloon platforms is presented.

  2. South Dakota Air National Guard Joe Foss Field, Sioux Falls, SD. Remedial Investigation

    DTIC Science & Technology

    1990-09-01

    obtaining a National Pollutant Discharge Elimination System (NPDES) permit relative to the remedial actions for groundwater treatment at Site 1...I Water samples are collected from these locations on a monthly basis and analyzed for conventional, inorganic, and bacteriological pollutants (fecal...cadmium, arsenic, and silver in the Big Sioux River at North Cliff Avenue just below the water treatment plant , approximately 1 mile east of the Base

  3. [Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira

    2014-01-01

    To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.

  4. - and Air-Broadened Line Shape Parameters of 12CH_4 : 4500-4620 CM-1

    NASA Astrophysics Data System (ADS)

    Devi, V. Malathy; Benner, D. Chris; Sung, Keeyoon; Brown, Linda; Crawford, Timothy J.; Smith, Mary Ann H.; Mantz, Arlan; Predoi-Cross, Adriana

    2014-06-01

    Accurate knowledge of spectral line shape parameters is important for infrared transmission and radiance calculations in the terrestrial atmosphere. We report the self- and air-broadened Lorentz widths, shifts and line mixing coefficients along with their temperature dependences for methane absorption lines in the 2.2 μm spectral region. For this, we obtained a series of high-resolution, high S/N spectra of 99.99% 12C-enriched samples of pure methane and its dilute mixtures in dry air at cold temperatures down to 150 K using the Bruker IFS 125HR Fourier transform spectrometer at JPL. The coolable absorption cell had an optical path of 20.38 cm and was specially built to reside inside the sample compartment of the Bruker FTS. The 13 spectra used in the analysis consisted of seven pure 12CH_4 spectra at pressures from 4.5 to 169 Torr and six air-broadened spectra with total sample pressures of 113-300 Torr and methane volume mixing ratios between 4 and 9.7%. These 13 spectra were fit simultaneously using the multispectrum least-squares fitting technique. The results will be compared to existing values reported in the literature. K. Sung, A. W. Mantz, L. R. Brown, et al., J. Mol. Spectrosc., 162 (2010) 124-134. D. C. Benner, C. P. Rinsland, V. Malathy Devi, M. A. H. Smith and D. Atkins, JQSRT, 53 (1995) 705-721. Research described in this paper was performed at Connecticut College, the College of William and Mary, NASA Langley Research Center and the Jet Propulsion Laboratory, California Institute of Technology, under contracts and cooperative agreements with the National Aeronautics and Space Administration.

  5. Microbial Dynamics during Aerobic Exposure of Corn Silage Stored under Oxygen Barrier or Polyethylene Films▿

    PubMed Central

    Dolci, Paola; Tabacco, Ernesto; Cocolin, Luca; Borreani, Giorgio

    2011-01-01

    The aims of this study were to compare the effects of sealing forage corn with a new oxygen barrier film with those obtained by using a conventional polyethylene film. This comparison was made during both ensilage and subsequent exposure of silage to air and included chemical, microbiological, and molecular (DNA and RNA) assessments. The forage was inoculated with a mixture of Lactobacillus buchneri, Lactobacillus plantarum, and Enterococcus faecium and ensiled in polyethylene (PE) and oxygen barrier (OB) plastic bags. The oxygen permeability of the PE and OB films was 1,480 and 70 cm3 m−2 per 24 h at 23°C, respectively. The silages were sampled after 110 days of ensilage and after 2, 5, 7, 9, and 14 days of air exposure and analyzed for fermentation characteristics, conventional microbial enumeration, and bacterial and fungal community fingerprinting via PCR-denaturing gradient gel electrophoresis (DGGE) and reverse transcription (RT)-PCR-DGGE. The yeast counts in the PE and OB silages were 3.12 and 1.17 log10 CFU g−1, respectively, with corresponding aerobic stabilities of 65 and 152 h. Acetobacter pasteurianus was present at both the DNA and RNA levels in the PE silage samples after 2 days of air exposure, whereas it was found only after 7 days in the OB silages. RT-PCR-DGGE revealed the activity of Aspergillus fumigatus in the PE samples from the day 7 of air exposure, whereas it appeared only after 14 days in the OB silages. It has been shown that the use of an oxygen barrier film can ensure a longer shelf life of silage after aerobic exposure. PMID:21821764

  6. Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.

    PubMed

    Woolfenden, Elizabeth

    2010-04-16

    Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents current state-of-the-art and recent developments in relevant areas such as sorbent research, sampler design, enhanced approaches to analytical quality assurance and on-tube derivatisation. Copyright 2009 Elsevier B.V. All rights reserved.

  7. Molecular detection of airborne Coccidioides in Tucson, Arizona

    USGS Publications Warehouse

    Chow, Nancy A.; Griffin, Dale W.; Barker, Bridget M.; Loparev, Vladimir N.; Litvintseva, Anastasia P.

    2016-01-01

    Environmental surveillance of the soil-dwelling fungus Coccidioides is essential for the prevention of Valley fever, a disease primarily caused by inhalation of the arthroconidia. Methods for collecting and detectingCoccidioides in soil samples are currently in use by several laboratories; however, a method utilizing current air sampling technologies has not been formally demonstrated for the capture of airborne arthroconidia. In this study, we collected air/dust samples at two sites (Site A and Site B) in the endemic region of Tucson, Arizona, and tested a variety of air samplers and membrane matrices. We then employed a single-tube nested qPCR assay for molecular detection. At both sites, numerous soil samples (n = 10 at Site A and n = 24 at Site B) were collected and Coccidioides was detected in two samples (20%) at Site A and in eight samples (33%) at Site B. Of the 25 air/dust samples collected at both sites using five different air sampling methods, we detected Coccidioides in three samples from site B. All three samples were collected using a high-volume sampler with glass-fiber filters. In this report, we describe these methods and propose the use of these air sampling and molecular detection strategies for environmental surveillance of Coccidioides.

  8. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.

  9. Power estimation using simulations for air pollution time-series studies

    PubMed Central

    2012-01-01

    Background Estimation of power to assess associations of interest can be challenging for time-series studies of the acute health effects of air pollution because there are two dimensions of sample size (time-series length and daily outcome counts), and because these studies often use generalized linear models to control for complex patterns of covariation between pollutants and time trends, meteorology and possibly other pollutants. In general, statistical software packages for power estimation rely on simplifying assumptions that may not adequately capture this complexity. Here we examine the impact of various factors affecting power using simulations, with comparison of power estimates obtained from simulations with those obtained using statistical software. Methods Power was estimated for various analyses within a time-series study of air pollution and emergency department visits using simulations for specified scenarios. Mean daily emergency department visit counts, model parameter value estimates and daily values for air pollution and meteorological variables from actual data (8/1/98 to 7/31/99 in Atlanta) were used to generate simulated daily outcome counts with specified temporal associations with air pollutants and randomly generated error based on a Poisson distribution. Power was estimated by conducting analyses of the association between simulated daily outcome counts and air pollution in 2000 data sets for each scenario. Power estimates from simulations and statistical software (G*Power and PASS) were compared. Results In the simulation results, increasing time-series length and average daily outcome counts both increased power to a similar extent. Our results also illustrate the low power that can result from using outcomes with low daily counts or short time series, and the reduction in power that can accompany use of multipollutant models. Power estimates obtained using standard statistical software were very similar to those from the simulations when properly implemented; implementation, however, was not straightforward. Conclusions These analyses demonstrate the similar impact on power of increasing time-series length versus increasing daily outcome counts, which has not previously been reported. Implementation of power software for these studies is discussed and guidance is provided. PMID:22995599

  10. Power estimation using simulations for air pollution time-series studies.

    PubMed

    Winquist, Andrea; Klein, Mitchel; Tolbert, Paige; Sarnat, Stefanie Ebelt

    2012-09-20

    Estimation of power to assess associations of interest can be challenging for time-series studies of the acute health effects of air pollution because there are two dimensions of sample size (time-series length and daily outcome counts), and because these studies often use generalized linear models to control for complex patterns of covariation between pollutants and time trends, meteorology and possibly other pollutants. In general, statistical software packages for power estimation rely on simplifying assumptions that may not adequately capture this complexity. Here we examine the impact of various factors affecting power using simulations, with comparison of power estimates obtained from simulations with those obtained using statistical software. Power was estimated for various analyses within a time-series study of air pollution and emergency department visits using simulations for specified scenarios. Mean daily emergency department visit counts, model parameter value estimates and daily values for air pollution and meteorological variables from actual data (8/1/98 to 7/31/99 in Atlanta) were used to generate simulated daily outcome counts with specified temporal associations with air pollutants and randomly generated error based on a Poisson distribution. Power was estimated by conducting analyses of the association between simulated daily outcome counts and air pollution in 2000 data sets for each scenario. Power estimates from simulations and statistical software (G*Power and PASS) were compared. In the simulation results, increasing time-series length and average daily outcome counts both increased power to a similar extent. Our results also illustrate the low power that can result from using outcomes with low daily counts or short time series, and the reduction in power that can accompany use of multipollutant models. Power estimates obtained using standard statistical software were very similar to those from the simulations when properly implemented; implementation, however, was not straightforward. These analyses demonstrate the similar impact on power of increasing time-series length versus increasing daily outcome counts, which has not previously been reported. Implementation of power software for these studies is discussed and guidance is provided.

  11. Snow crystal imaging using scanning electron microscopy: III. Glacier ice, snow and biota

    USGS Publications Warehouse

    Rango, A.; Wergin, W.P.; Erbe, E.F.; Josberger, E.G.

    2000-01-01

    Low-temperature scanning electron microscopy (SEM) was used to observe metamorphosed snow, glacial firn, and glacial ice obtained from South Cascade Glacier in Washington State, USA. Biotic samples consisting of algae (Chlamydomonas nivalis) and ice worms (a species of oligochaetes) were also collected and imaged. In the field, the snow and biological samples were mounted on copper plates, cooled in liquid nitrogen, and stored in dry shipping containers which maintain a temperature of -196??C. The firn and glacier ice samples were obtained by extracting horizontal ice cores, 8 mm in diameter, at different levels from larger standard glaciological (vertical) ice cores 7.5 cm in diameter. These samples were cooled in liquid nitrogen and placed in cryotubes, were stored in the same dry shipping container, and sent to the SEM facility. In the laboratory, the samples were sputter coated with platinum and imaged by a low-temperature SEM. To image the firn and glacier ice samples, the cores were fractured in liquid nitrogen, attached to a specimen holder, and then imaged. While light microscope images of snow and ice are difficult to interpret because of internal reflection and refraction, the SEM images provide a clear and unique view of the surface of the samples because they are generated from electrons emitted or reflected only from the surface of the sample. In addition, the SEM has a great depth of field with a wide range of magnifying capabilities. The resulting images clearly show the individual grains of the seasonal snowpack and the bonding between the snow grains. Images of firn show individual ice crystals, the bonding between the crystals, and connected air spaces. Images of glacier ice show a crystal structure on a scale of 1-2 mm which is considerably smaller than the expected crystal size. Microscopic air bubbles, less than 15 ??m in diameter, clearly marked the boundaries between these crystal-like features. The life forms associated with the glacier were easily imaged and studied. The low-temperature SEM sample collecting and handling methods proved to be operable in the field; the SEM analysis is applicable to glaciological studies and reveals details unattainable by conventional light microscopic methods.Low temperature scanning electron microscopy (SEM) was used to observe metamorphosed snow, glacial firn, and glacial ice obtained from South Cascade Glacier in Washington State, USA. Biotic samples consisting of algae and ice worms were also collected and imaged. The SEM images provide a clear and unique view of the surface of the samples because they are generated from electrons emitted or reflected only from the surface of the sample. The SEM has a great depth of field with a wide range of magnifying capabilities.

  12. Temperature field of dielectric films under continuous ion-beam irradiation

    NASA Astrophysics Data System (ADS)

    Salikhov, T. Kh.; Abdurahmonov, A. A.

    2017-11-01

    In the present study, we theoretically examine the formation process of the steady-state temperature field in dielectrics under irradiation with a continuous ion beam in air with allowance for the temperature dependence of thermophysical quantities. Analytical expressions for the temperature field were obtained. An interconnected system of nonlinear algebraic equations for the steady-state temperatures at the front (irradiated) and rear surfaces of the sample, and the steady-state temperature at the interface between the ion-damaged and non-damaged region was obtained; by numerical solution of this system, a nonlinear dependence of the mentioned temperatures on the characteristics of incident ion flux was revealed.

  13. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry.

    PubMed

    Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.

  14. Preparation of isolated biomolecules for SFM observations: T4 bacteriophage as a test sample.

    PubMed Central

    Droz, E; Taborelli, M; Wells, T N; Descouts, P

    1993-01-01

    The T4 bacteriophage has been used to investigate protocols for the preparation of samples for scanning force microscopy in air, in order to obtaining reproducible images. The resolution of images and the distribution of bacteriophages on the substrate depends on the buffer type, its concentration, the surface treatment of substrate, and the method of deposition. The best imaging conditions for the phages require dilution in a volatile buffer at low ionic strength and adsorption onto hydrophilic surfaces. When imaging with the scanning force microscopy the quality of the images is influenced by the vertical and lateral forces applied on the sample and by the tip geometry. Images FIGURE 1 FIGURE 2 FIGURE 4 FIGURE 5 FIGURE 6 PMID:8241398

  15. Natural Radioactivity of Boron Added Clay Samples

    NASA Astrophysics Data System (ADS)

    Akkurt, I.; ćanakciı, H.; Mavi, B.; Günoǧlu, K.

    2011-12-01

    Clay, consisting fine-grained minerals, is an interesting materials and can be used in a variety of diferent fields especially in dermatology application. Using clay such a field it is important to measure its natural radioacitivty. Thus the purpose of this study is to measure 226Ra, 232Th and 40K concentration in clay samples enriched with boron. Three different types of clay samples were prepared where boron is used in different rate. The measurements have been determined using a gamma-ray spectrometry consists of a 3″×3″ NaI(Tl) detector. From the measured activity the radium equivalent activities (Raeq), external hazard index (Hex), absorbed dose rate in air (D) and annual effective dose (AED) have also been obtained.

  16. X-ray photoelectron spectroscopy study of chemically-etched Nd-Ce-Cu-O surfaces

    NASA Technical Reports Server (NTRS)

    Vasquez, R. P.; Gupta, A.; Kussmaul, A.

    1991-01-01

    Acetic acid, Br2, and HCl solutions are investigated for removing insulating species from Nd(1.85)Ce(0.15)CuO(4-delta) (NCCO) thin film surfaces. X-ray photoelectron spectroscopy (XPS) shows that the HCl etch is most effective, yielding O 1s spectra comparable to those obtained from samples cleaned in vacuum and a clear Fermi edge in the valence band region. Reduction and oxidation reversibly induces and eliminates, respectively, Fermi level states for undoped samples, but has no clearly observable effect on the XPS spectra for doped samples. Reactivity to air is much less for NCCO compared to hole superconductors, which is attributed to the lack of reactive alkaline earth elements in NCCO.

  17. Passive Sampling for Indoor and Outdoor Exposures to Chlorpyrifos, Azinphos-Methyl, and Oxygen Analogs in a Rural Agricultural Community.

    PubMed

    Gibbs, Jenna L; Yost, Michael G; Negrete, Maria; Fenske, Richard A

    2017-03-01

    Recent studies have highlighted the increased potency of oxygen analogs of organophosphorus pesticides. These pesticides and oxygen analogs have previously been identified in the atmosphere following spray applications in the states of California and Washington. We used two passive sampling methods to measure levels of the ollowing organophosphorus pesticides: chlorpyrifos, azinphos-methyl, and their oxygen analogs at 14 farmworker and 9 non-farmworker households in an agricultural region of central Washington State in 2011. The passive methods included polyurethane foam passive air samplers deployed outdoors and indoors and polypropylene deposition plates deployed indoors. We collected cumulative monthly samples during the pesticide application seasons and during the winter season as a control. Monthly outdoor air concentrations ranged from 9.2 to 199 ng/m 3 for chlorpyrifos, 0.03 to 20 ng/m 3 for chlorpyrifos-oxon, < LOD (limit of detection) to 7.3 ng/m 3 for azinphos-methyl, and < LOD to 0.8 ng/m 3 for azinphos-methyl-oxon. Samples from proximal households (≤ 250 m) had significantly higher outdoor air concentrations of chlorpyrifos, chlorpyrifos-oxon, and azinphos-methyl than did samples from nonproximal households ( p ≤ 0.02). Overall, indoor air concentrations were lower than outdoors. For example, all outdoor air samples for chlorpyrifos and 97% of samples for azinphos-methyl were > LOD. Indoors, only 78% of air samples for chlorpyrifos and 35% of samples for azinphos-methyl were > LOD. Samples from farmworker households had higher indoor air concentrations of both pesticides than did samples from non-farmworker households. Mean indoor and outdoor air concentration ratios for chlorpyrifos and azinphos-methyl were 0.17 and 0.44, respectively. We identified higher levels in air and on surfaces at both proximal and farmworker households. Our findings further confirm the presence of pesticides and their oxygen analogs in air and highlight their potential for infiltration of indoor living environments. Citation: Gibbs JL, Yost MG, Negrete M, Fenske RA. 2017. Passive sampling for indoor and outdoor exposures to chlorpyrifos, azinphos-methyl, and oxygen analogs in a rural agricultural community. Environ Health Perspect 125:333-341; http://dx.doi.org/10.1289/EHP425.

  18. Breathing zone air sampler

    DOEpatents

    Tobin, John

    1989-01-01

    A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

  19. Activated carbon derived from chitosan as air cathode catalyst for high performance in microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Liu, Yi; Zhao, Yong; Li, Kexun; Wang, Zhong; Tian, Pei; Liu, Di; Yang, Tingting; Wang, Junjie

    2018-02-01

    Chitosan with rich of nitrogen is used as carbon precursor to synthesis activated carbon through directly heating method in this study. The obtained carbon is activated by different amount of KOH at different temperatures, and then prepared as air cathodes for microbial fuel cells. Carbon sample treated with double amount of KOH at 850 °C exhibits maximum power density (1435 ± 46 mW m-2), 1.01 times improved, which ascribes to the highest total surface area, moderate micropore and mesoporous structure and the introduction of nitrogen. The electrochemical impedance spectroscopy and powder resistivity state that carbon treated with double amount of KOH at 850 °C possesses lower resistance. The other electrochemical measurements demonstrate that the best kinetic activity make the above treated sample to show the best oxygen reduction reaction activity. Besides, the degree of graphitization of samples increases with the activated temperature increasing, which is tested by Raman. According to elemental analysis and X-ray photoelectron spectroscopy, all chitosan samples are nitrogen-doped carbon, and high content nitrogen (pyridinic-N) improves the electrochemical activity of carbon treated with KOH at 850 °C. Thus, carbon materials derived from chitosan would be an optimized catalyst for oxygen reduction reaction in microbial fuel cell.

  20. Evaluation and mapping of PM2.5 atmospheric aerosols in Arasia region using PIXE and gravimetric measurements

    NASA Astrophysics Data System (ADS)

    Roumie, M.; Chiari, M.; Srour, A.; Sa'adeh, H.; Reslan, A.; Sultan, M.; Ahmad, M.; Calzolai, G.; Nava, S.; Zubaidi, Th.; Rihawy, M. S.; Hussein, T.; Arafah, D.-E.; Karydas, A. G.; Simon, A.; Nsouli, B.

    2016-03-01

    The present work is a part of a scientific study conducted among several Arab countries in west Asia, under an International Atomic Energy Agency (IAEA) regional technical cooperation project for Arasia region. The project aims at producing for the first time a database of particulate matter (PM) elemental concentrations in the region that will help in future air quality studies in order to identify commonalities and differences in the presence and contribution of fingerprint pollution sources among the Arasia Member States. The first regional campaign was launched simultaneously in Lebanon, Iraq, Jordan, Syria and United Arab Emirates, using a harmonized sampling and analysis protocol of PM10 and PM2.5 samples. Different samples, collected between October 2014 and February 2015, from the participating countries, were analyzed by PIXE technique and gravimetric measurements were also carried out. The first results of the study will be discussed in a regional perspective. Our study shows that concentrations of fine aerosol fractions are often exceeding the WHO standard values as well as showing some disparities in the obtained values between the different sampling sites. However, some trend similarities of variations with time could also be observed, suggesting a common influence by trans-boundary or external sources of air pollution.

  1. Performance of commercial aluminium alloys as anodes in gelled electrolyte aluminium-air batteries

    NASA Astrophysics Data System (ADS)

    Pino, M.; Chacón, J.; Fatás, E.; Ocón, P.

    2015-12-01

    The evaluation of commercial aluminium alloys, namely, Al2024, Al7475 and Al1085, for Al-air batteries is performed. Pure Al cladded Al2024 and Al7475 are also evaluated. Current rates from 0.8 mA cm-2 to 8.6 mA cm-2 are measured in a gel Al-air cell composed of the commercial alloy sample, a commercial air-cathode and an easily synthesizable gelled alkaline electrolyte. The influence of the alloying elements and the addition to the electrolyte of ZnO and ZnCl2, as corrosion inhibitors is studied and analysed via EDX/SEM. Specific capacities of up to 426 mAh/g are obtained with notably flat potential discharges of 1.3-1.4 V. The competition between self-corrosion and oxidation reactions is also discussed, as well as the influence of the current applied on that process. Al7475 is determined to have the best behaviour as anode in Al-air primary batteries, and cladding process is found to be an extra protection against corrosion at low current discharges. Conversely, Al1085 provided worse results because of an unfavourable metallic composition.

  2. Fuel-Flexible Gas Turbine Combustor Flametube Facility

    NASA Technical Reports Server (NTRS)

    Little, James E.; Nemets, Stephen A.; Tornabene, Robert T.; Smith, Timothy D.; Frankenfield, Bruce J.; Manning, Stephen D.; Thompson, William K.

    2004-01-01

    Facility modifications have been completed to an existing combustor flametube facility to enable testing with gaseous hydrogen propellants at the NASA Glenn Research Center. The purpose of the facility is to test a variety of fuel nozzle and flameholder hardware configurations for use in aircraft combustors. Facility capabilities have been expanded to include testing with gaseous hydrogen, along with the existing hydrocarbon-based jet fuel. Modifications have also been made to the facility air supply to provide heated air up to 350 psig, 1100 F, and 3.0 lbm/s. The facility can accommodate a wide variety of flametube and fuel nozzle configurations. Emissions and performance data are obtained via a variety of gas sample probe configurations and emissions measurement equipment.

  3. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA: Spectral and temporal characteristics of a laser plasma

    NASA Astrophysics Data System (ADS)

    Lipchak, A. I.; Solomonov, V. I.; Tel'nov, V. A.; Osipov, V. V.

    1995-04-01

    An experimental investigation was made of the spectral and temporal characteristics of a laser plasma formed by the interaction of a CO2 laser pulse with a target in atmospheric air. The results obtained indicate that the main role in the process of filling the excited states in a laser plasma is played by a recombination cascade and that both atoms and molecules of the atmospheric gases are excited. The result also show that a laser plasma can be used in spectroscopic analysis of multicomponent samples. The solution of the thermophysical problem of heating of a target by laser radiation supports the existing ideas on the process of formation of a plasma near the target surface in air.

  4. Adsorption of xenon and krypton on shales

    NASA Technical Reports Server (NTRS)

    Podosek, F. A.; Bernatowicz, T. J.; Kramer, F. E.

    1981-01-01

    A method that uses a mass spectrometer as a manometer is employed in the measurement of Xe and Kr adsorption parameters on shales and related samples, where gas partial pressures were lower than 10 to the -11th atm, corresponding adsorption coverages are only small fractions of a monolayer, and Henry's Law behavior is expected and observed. Results show heats of adsorption in the 2-7 kcal/mol range, and Henry constants at 0-25 C of 1 cu cm STP/g per atmosphere are extrapolated. Although the adsorption properties obtained are variable by sample, the range obtained suggests that shales may be capable of an equilibrium adsorption with modern air high enough to account for a significant fraction of the atmospheric inventory of Xe, and perhaps even of Kr. This effect will nevertheless not account for the factor-of-25 defficiency of atmospheric Xe, in comparison with the planetary gas patterns observed in meteorites.

  5. Indoor air and respiratory health in preadolescent children

    NASA Astrophysics Data System (ADS)

    Gomzi, M.

    The effect of indoor exposure to nitrogen dioxide, ammonia, particulate matter and parental tobacco smoke on respiratory health was studied over a period of six months in all second graders born and living in two area of continental Croatia 8-10 yr of age. The study group was divided into two sections corresponding to area of residence (industrial/rural). Information on respiratory symptoms was collected from a self-administered questionnaire completed by the parents of the children. The mean values of concentrations of indoor air pollution that had been recorded in 24-h samples of air collected at schools were mostly below threshold limit for ambient pollution. In addition, information on parental smoking, the density of habitation and the type of fuel used for heating and/or cooking in the home was obtained by a questionnaire. In the investigated period the prevalence of respiratory illness was 22% in the children exposed to lower indoor air pollution and 25% in those exposed to higher indoor air pollution. Exposure to parental smoking was also associated with more respiratory symptoms (28 : 19%). The results indicate that the measured air pollutants only had a slight effect on the respiratory health of preadolescent children. However, the effect of exposure to parental smoking was more pronounced.

  6. Application of multicriteria decision making methods to air quality in the microenvironments of residential houses in Brisbane, Australia.

    PubMed

    Ayoko, Godwin A; Morawska, Lidia; Kokot, Serge; Gilbert, Dale

    2004-05-01

    This paper reports the first application of the multicriteria decision making methods, PROMETHEE and GAIA, to indoor and outdoor air quality data. Fourteen residential houses in a suburb of Brisbane, Australia were investigated for 21 air quality-influencing criteria, which included the characteristics of the houses as well as the concentrations of volatile organic compounds, fungi, bacteria, submicrometer, and supermicrometer particles in their indoor and outdoor air samples. Ranking information necessary to select one house in preference to all others and to assess the parameters influencing the differentiation of the houses was found with the aid of PROMETHEE and GAIA. There was no correlation between the rank order of each house and the health complaints of its occupants. Patterns in GAIA plots show that indoor air quality in these houses is strongly dependent on the characteristics of the houses (construction material, distance of the house from a major road, and the presence of an in-built garage). Marked similarities were observed in the patterns obtained when GAIA and factor analysis were applied to the data. This underscores the potential of PROMETHEE and GAIA to provide information that can assist source apportionment and elucidation of effective remedial measures for indoor air pollution.

  7. Assessment of the Minimum Sampling Frequency to Avoid Measurement Redundancy in Microclimate Field Surveys in Museum Buildings.

    PubMed

    García-Diego, Fernando-Juan; Verticchio, Elena; Beltrán, Pedro; Siani, Anna Maria

    2016-08-15

    Monitoring temperature and relative humidity of the environment to which artefacts are exposed is fundamental in preventive conservation studies. The common approach in setting measuring instruments is the choice of a high sampling rate to detect short fluctuations and increase the accuracy of statistical analysis. However, in recent cultural heritage standards the evaluation of variability is based on moving average and short fluctuations and therefore massive acquisition of data in slowly-changing indoor environments could end up being redundant. In this research, the sampling frequency to set a datalogger in a museum room and inside a microclimate frame is investigated by comparing the outcomes obtained from datasheets associated with different sampling conditions. Thermo-hygrometric data collected in the Sorolla room of the Pio V Museum of Valencia (Spain) were used and the widely consulted recommendations issued in UNI 10829:1999 and EN 15757:2010 standards and in the American Society of Heating, Air-Conditioning and Refrigerating Engineers (ASHRAE) guidelines were applied. Hourly sampling proved effective in obtaining highly reliable results. Furthermore, it was found that in some instances daily means of data sampled every hour can lead to the same conclusions as those of high frequency. This allows us to improve data logging design and manageability of the resulting datasheets.

  8. Assessment of the Minimum Sampling Frequency to Avoid Measurement Redundancy in Microclimate Field Surveys in Museum Buildings

    PubMed Central

    García-Diego, Fernando-Juan; Verticchio, Elena; Beltrán, Pedro; Siani, Anna Maria

    2016-01-01

    Monitoring temperature and relative humidity of the environment to which artefacts are exposed is fundamental in preventive conservation studies. The common approach in setting measuring instruments is the choice of a high sampling rate to detect short fluctuations and increase the accuracy of statistical analysis. However, in recent cultural heritage standards the evaluation of variability is based on moving average and short fluctuations and therefore massive acquisition of data in slowly-changing indoor environments could end up being redundant. In this research, the sampling frequency to set a datalogger in a museum room and inside a microclimate frame is investigated by comparing the outcomes obtained from datasheets associated with different sampling conditions. Thermo-hygrometric data collected in the Sorolla room of the Pio V Museum of Valencia (Spain) were used and the widely consulted recommendations issued in UNI 10829:1999 and EN 15757:2010 standards and in the American Society of Heating, Air-Conditioning and Refrigerating Engineers (ASHRAE) guidelines were applied. Hourly sampling proved effective in obtaining highly reliable results. Furthermore, it was found that in some instances daily means of data sampled every hour can lead to the same conclusions as those of high frequency. This allows us to improve data logging design and manageability of the resulting datasheets. PMID:27537886

  9. Technical note: Air compared to nitrogen as nebulizing and drying gases for electrospray ionization mass spectrometry.

    PubMed

    Mielczarek, P; Silberring, J; Smoluch, M

    In the present study we tested the application of compressed air instead of pure nitrogen as the nebulizing and drying gas, and its influence on the quality of electrospray ionization (ESI) mass spectra. The intensities of the signals corresponding to protonated molecules were significantly (twice) higher when air was used. Inspection of signal-to-noise (S/N) ratios revealed that, in both cases, sensitivity was comparable. A higher ion abundance after the application of compressed air was followed by a higher background. Another potential risk of using air in the ESI source is the possibility for sample oxidation due to the presence of oxygen. To test this, we selected five easily oxidizing compounds to verify their susceptibility to oxidation. In particular, the presence of methionine was of interest. For all the compounds studied, no oxidation was observed. Amodiaquine oxidizes spontaneously in water solutions and its oxidized form can be detected a few hours after preparation. Direct comparison of the spectra where nitrogen was used with the corresponding spectra obtained when air was applied did not show significant differences. The only distinction was slightly different patterns of adducts when air was used. The difference concerns acetonitrile, which forms higher signals when air is the nebulizing gas. It is also important that the replacement of nitrogen with air does not affect quantitative data. The prepared calibration curves also visualize an intensity twice as high (independent of concentration within tested range) of the signal where air was applied. We have used our system continuously for three months with air as the nebulizing and drying gas and have not noticed any unexpected signal deterioration caused by additional source contamination from the air. Moreover, compressed air is much cheaper and easily available using oil-free compressors or pumps.

  10. Sequential air sampler system : its use by the Virginia Department of Highways & Transportation.

    DOT National Transportation Integrated Search

    1975-01-01

    The Department of Highways & Transportation needs an economical and efficient air quality sampling system for meeting requirements on air monitoring for proposed projects located In critical areas. Two sequential air sampling systems, the ERAI and th...

  11. Synopsis of TC4 Missions and Meteorology

    NASA Astrophysics Data System (ADS)

    Starr, D.; Pfister, L.; Selkirk, H.; Nguyen, L.

    2007-12-01

    The TC4 (Tropical Composition, Clouds and Climate Coupling) Experiment conducted 26 aircraft sorties on 13 flight days from July 17 to August 8, 2007 (23 days). Quality science observations were also obtained during the transit flights to/from from San Jose, Costa Rica, where the mission was based. On 9 days, coordinated aircraft missions were flown with the NASA ER-2 and DC-8, and with the NASA WB-57 on 3 occasions (and transit flights). The ER-2 served as an A-Train simulator (MODIS, CloudSat, CALIPSO, AIRS/TES, partial AMSR-E) while the WB-57 provided in-situ measurements of upper tropospheric cloud particles, aerosols and trace gases. The DC-8 provided both in-situ and remote sensing measurements, where the latter were focused on Aura validation, and also including a down-looking scanning precipitation radar (TRMM PR simulator). This paper will provide a synopsis of the science observations that were obtained, as regards the clouds and cloud systems sampled, from a meteorological perspective. A diversity of clouds were sampled and the meteorology proved more interesting than expected, at least to this author. Upper tropospheric cirrus outflows were sampled from a number of convective cloud systems including ITCZ-type systems as well as systems close to and affected by land. The low level inflows to these systems were also sampled in some cases (DC-8) and missions were flown to sample stratocumulus clouds over the Pacific Ocean exploiting the unique instrumentation on the DC-8 to add to the knowledge of these clouds which are so important to the Earth radiation budget. Measurements were made in the tropical Tropopause Transition Layer (TTL) by the WB-57. Upper tropospheric clouds and TTL properties and processes were central TC4 objectives. Excellent data were also obtained on the fate of the Saharan Air Layer and its aerosols over the Caribbean and Central America, as well as samples of plumes from volcanoes in Ecuador and Columbia and biogenic emissions over Columbia and the Pacific Ocean. Satellite observations, including those from various A-Train sensors, were used in planning the missions which were, in many cases, coordinated, at least in part, with satellite overpasses, especially Aura and other A-Train sensors (DC-8) and Terra.

  12. Oxidative potential and chemical composition of PM2.5 in office buildings across Europe - The OFFICAIR study.

    PubMed

    Szigeti, Tamás; Dunster, Christina; Cattaneo, Andrea; Cavallo, Domenico; Spinazzè, Andrea; Saraga, Dikaia E; Sakellaris, Ioannis A; de Kluizenaar, Yvonne; Cornelissen, Eric J M; Hänninen, Otto; Peltonen, Matti; Calzolai, Giulia; Lucarelli, Franco; Mandin, Corinne; Bartzis, John G; Záray, Gyula; Kelly, Frank J

    2016-01-01

    In the frame of the OFFICAIR project, indoor and outdoor PM2.5 samples were collected in office buildings across Europe in two sampling campaigns (summer and winter). The ability of the particles to deplete physiologically relevant antioxidants (ascorbic acid (AA), reduced glutathione (GSH)) in a synthetic respiratory tract lining fluid, i.e., oxidative potential (OP), was assessed. Furthermore, the link between particulate OP and the concentration of the PM constituents was investigated. The mean indoor PM2.5 mass concentration values were substantially lower than the related outdoor values with a mean indoor/outdoor PM2.5 mass concentration ratio of 0.62 and 0.61 for the summer and winter campaigns respectively. The OP of PM2.5 varied markedly across Europe with the highest outdoor OP(AA) m(-3) and OP(GSH) m(-3) (% antioxidant depletion/m(3) air) values obtained for Hungary, while PM2.5 collected in Finland exhibited the lowest values. Seasonal variation could be observed for both indoor and outdoor OP(AA) m(-3) and OP(GSH) m(-3) with higher mean values during winter. The indoor/outdoor OP(AA) m(-3) and OP(GSH) m(-3) ratios were less than one with 4 and 17 exceptions out of the 40 cases respectively. These results indicate that indoor air is generally less oxidatively challenging than outdoors. Correlation analysis revealed that trace elements play an important role in determining OP, in particular, the Cu content. Indoor air chemistry might affect OP since weaker correlations were obtained for indoor PM2.5. Our findings also suggest that office workers may be exposed to health relevant PM constituents to a different extent within the same building. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Nasal variation in relation to high-altitude adaptations among Tibetans and Andeans.

    PubMed

    Butaric, Lauren N; Klocke, Ross P

    2018-05-01

    High-altitude (>2500 m) populations face several pressures, including hypoxia and cold-dry air, resulting in greater respiratory demand to obtain more oxygen and condition inspired air. While cardiovascular and pulmonary adaptations to high-altitude hypoxia have been extensively studied, adaptations of upper-respiratory structures, e.g., nasal cavity, remain untested. This study investigates whether nasal morphology presents adaptations to hypoxic (larger noses) and/or cold-dry (tall/narrow noses) conditions among high-altitude samples. CT scans of two high- and four low-altitude samples from diverse climates were collected (n = 130): high-altitude Tibetans and Peruvians; low-altitude Peruvians, Southern Chinese (temperate), Mongolian-Buriats (cold-dry), and Southeast Asians (hot-wet). Facial and nasal distances were calculated from 3D landmarks placed on digitally-modeled crania. Temperature, precipitation, and barometric pressure data were also obtained. Principal components analysis and analyses of variance primarily indicate size-related differences among the cold-dry (Mongolian-Buriats) and hot-wet (Southeast Asians) adapted groups. Two-block partial least squares (PLS) analysis show weak relationships between size-standardized nasal dimensions and environmental variables. However, among PLS1 (85.90% of covariance), Tibetans display relatively larger nasal cavities related to lower temperatures and barometric pressure; regression analyses also indicate high-altitude Tibetans possess relatively larger internal nasal breadths and heights for their facial size. Overall, nasal differences relate to climate among the cold-dry and hot-wet groups. Specific nasal adaptations were not identified among either Peruvian group, perhaps due to their relatively recent migration history and population structure. However, high-altitude Tibetans seem to exhibit a compromise in nasal morphology, serving in increased oxygen uptake, and air-conditioning processes. © 2018 Wiley Periodicals, Inc.

  14. Failure of enzyme encapsulation to prevent sensitization of workers in the dry bleach industry.

    PubMed

    Liss, G M; Kominsky, J R; Gallagher, J S; Melius, J; Brooks, S M; Bernstein, I L

    1984-03-01

    BDE added to dry bleach have been associated with immunologic sensitization and development of clinical allergic disease in detergent workers and occasionally in consumers. However, improved dust control and modification of the manufacturing process through encapsulation of enzyme were believed to have reduced or eliminated these problems. To determine whether or not immunologic sensitization could still develop in the detergent industry, we studied employees of a dry bleach manufacturing plant that incorporated encapsulated BDE into a consumer product. We performed air sampling for enzyme dust and total particulates, administered questionnaires, conducted physical examinations, and spirometry in 13 currently exposed, two previously exposed and nine nonexposed, employees. To assess sensitization status, RAST and ELISA were performed. Air concentrations of enzyme dust ranged from 0.002 to 1.57 micrograms/m3; all of these levels were below the TLV of 3.9 micrograms/m3. Positive BDE-specific RAST results (3.4%, 4.4%, and 8.0% binding) were obtained in three of 12 currently exposed workers. Results of personal breathing-zone air sampling indicated that these workers had high dust-exposure levels. Specificity of RAST was verified by RAST inhibition with BDE. BDE-RAST binding was not significantly elevated in the nonworkers (range: 0.6% to 1.4% binding). Positive results for specific IgG by ELISA were obtained in four of 12 currently exposed and in one of two previously exposed workers but in none of the nonexposed workers. We conclude that immunologic sensitization can develop after occupational exposure to encapsulated BDE in the dry bleach industry. We have not proved, however, that this immunologic reactivity is related to clinical sensitivity.

  15. Thermal and sonochemical synthesis of porous (Ce,Zr)O2 mixed oxides from metal β-diketonate precursors and their catalytic activity in wet air oxidation process of formic acid.

    PubMed

    Cau, Camille; Guari, Yannick; Chave, Tony; Larionova, Joulia; Nikitenko, Sergey I

    2014-07-01

    Porous (Ce0.5Zr0.5)O2 solid solutions were prepared by thermolysis (T=285 °C) or sonolysis (20 kHz, I=32 W cm(-2), Pac=0.46 W mL(-1), T=200 °C) of Ce(III) and Zr(IV) acetylacetonates in oleylamine or hexadecylamine under argon followed by heat treatment of the precipitates obtained in air at 450 °C. Transmission Electron Microscopy images of the samples show nanoparticles of ca. 4-6 nm for the two synthetic approaches. The powder X-ray diffraction, scanning electron microscopy, energy dispersive X-ray and μ-Raman spectroscopy of solids obtained after heat treatment indicate the formation of (Ce0.5Zr0.5)O2 solid solutions with a metastable tetragonal crystal structure for the two synthetic routes. The specific surface area of the samples varies between 78 and 149 m(2) g(-1) depending on synthesis conditions. The use of Barrett-Joyner-Halenda and t-plot methods reveal the formation of mixed oxides with a hybrid morphology that combines mesoporosity and microporosity regardless of the method of preparation. Platinum nanoparticles were deposited on the surface of the mixed oxides by sonochemical reduction of Pt(IV). It was found that the materials prepared by sonochemistry exhibit better resistance to dissolution during the deposition process of platinum. X-ray photoelectron spectroscopy analysis shows the presence of Pt(0) and Pt(II) on the surface of mixed oxides. Porous (Ce0.5Zr0.5)O2 mixed oxides loaded with 1.5%wt. platinum exhibit high activity in catalytic wet air oxidation of formic acid at 40 °C. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Identification of Chemicals of Interest to the Department of Defense and U.S. Air Force Among the U.S. Environmental Protection Agency’s Integrated Risk Information System Chemicals that are Due for Reassessment of their Toxicity Values

    DTIC Science & Technology

    2010-03-16

    Exceeded at ERP Soil and Groundwater Sites 86 A-2a. Identification of IRIS Chemicals of Interest on the ATSDR CERCLA Priority List of Hazardous...the Number (Bold Font) of Air Force ERP Samples in Which They Were Detected 317 A-4d. Air Force ERP Soil Samples: IRIS Chemicals of Interest...Ranked by the Number (Bold Font) of Air Force ERP Soil Samples in Which They Were Detected 333 A-4e. Air Force ERP Groundwater Samples: IRIS Chemicals of

  17. Presence of pathogenic microorganisms in power-plant cooling waters. Final report, October 1, 1981-June 30, 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyndall, R.L.

    1983-07-01

    Air was sampled at the point of discharge and at short distances downwind and upwind from industrial and power-plant cooling towers. Both high-volume electrostatic and impinger type samplers were used. Concentrates of the air samples were analyzed for Legionnaires' Disease Bacteria (LDB). In some cases, the samples were also tested for the presence of free-living amoebae. The concentrations of LDB in the air samples were well below the minimal infectious dose for guinea pigs and precluded testing of the samples for infectious LDB. Results of LDB analysis were related to the meteorological conditions at the time of sampling. Generally, themore » concentrations of LDB in the air at the discharge of the cooling towers were 1 x 10/sup -6/ to 1 x 10/sup -7/ of that found in comparable volumes of tower basin water. During periods of high humidity and wind speed, LDB was detected in a few downwind samples and one upwind sample. One site with extensive construction and excavation activity had higher LDB concentrations in air samples relative to other sites. Nonpathogenic Naegleria were present in one of two air samples taken in the mist at the base of a natural-draft cooling tower.« less

  18. Three common faults in current practice that influence the validity of data obtained from electronic air pollution instrumentation.

    PubMed

    Dowd, G; Thomas, R S; Monkman, J L

    1975-01-01

    Instrumental development is now entering a more logical era, where the former artistic character of electronics is being replaced by cold technology. Because of this, one should be expect more reliability; however, there still exist many weak links in practical application. Digital readout systems and computer processing induce a false sense of security. In reality, it is the sample-measurement relationship that determines an instrument's credibility and not the number of digits on its meter. In describing three faulty practices that greatly influence an instrument's performance, it is hoped that measurement may be more closely related to the sample!

  19. Vertical profiles of CO and CH4 in the lower and middle troposphere over the Eastern United States January 1978

    NASA Technical Reports Server (NTRS)

    Reichle, H. G., Jr.; Condon, E. P.

    1979-01-01

    Samples of tropospheric air were obtained over the Eastern United States during January of 1978. These samples were analyzed by gas chromatography using flame ionization detection to produce vertical profiles of carbon monoxide and methane from the surface to 8 km. The carbon monoxide mixing ratios at 35 deg N and 45 deg N agree with previously published values; however, the mixing ratio at 25 deg N was significantly lower than most published values. The methane mixing ratio was weakly dependent on latitude and has an average value of 1.64 ppm.

  20. Air sampling results in relation to extent of fungal colonization of building materials in some water-damaged buildings.

    PubMed

    Miller, J D; Haisley, P D; Reinhardt, J H

    2000-09-01

    We studied the extent and nature of fungal colonization of building materials in 58 naturally ventilated apartments that had suffered various kinds of water damage in relation to air sampling done before the physical inspections. The results of air samples from each apartment were compared by rank order of species with pooled data from outdoor air. Approximately 90% of the apartments that had significant amounts of fungi in wall cavities were identified by air sampling. There was no difference in the average fungal colony forming unit values per m3 between the 15 apartments with the most fungal contamination and the 15 with the least. In contrast, the prevalence of samples with fungal species significantly different than the pooled outdoor air between the more contaminated versus the less contaminated apartments was approximately 10-fold. We provide information on methods to document fungal contamination in buildings.

Top