Science.gov

Sample records for air sampling method

  1. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

    SciTech Connect

    Maxwell, S.; Noyes, G.; Culligan, B.

    2010-02-03

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

  2. Passive Samplers for Investigations of Air Quality: Method Description, Implementation, and Comparison to Alternative Sampling Methods

    EPA Science Inventory

    This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...

  3. Identification of ambient air sampling and analysis methods for the 189 Title III air toxics

    SciTech Connect

    Mukund, R.; Kelly, T.J.; Gordon, S.M.; Hays, M.J.

    1994-12-31

    The state of development of ambient air measurement methods for the 189 Hazardous Air Pollution (HAPs) in Title 3 of the Clean Air Act Amendments was surveyed. Measurement methods for the HAPs were identified by reviews of established methods, and by literature searches for pertinent research techniques. Methods were segregated by their degree of development into Applicable, Likely, and Potential methods. This survey identified a total of 183 methods, applicable at varying degrees to ambient air measurements of one or more HAPs. As a basis for classifying the HAPs and evaluating the applicability of measurement methods, a survey of a variety of chemical and physical properties of the HAPs was also conducted. The results of both the methods and properties surveys were tabulated for each of the 189 HAP. The current state of development of ambient measurement methods for the 189 HAPs was then assessed from the results of the survey, and recommendations for method development initiatives were developed.

  4. Review of Various Air Sampling Methods for Solvent Vapors.

    ERIC Educational Resources Information Center

    Maykoski, R. T.

    Vapors of trichloroethylene, toluene, methyl ethyl ketone, and butyl cellosolve in air were collected using Scotchpac and Tedlar bags, glass prescription bottles, and charcoal adsorption tubes. Efficiencies of collection are reported. (Author/RH)

  5. A method to optimize sampling locations for measuring indoor air distributions

    NASA Astrophysics Data System (ADS)

    Huang, Yan; Shen, Xiong; Li, Jianmin; Li, Bingye; Duan, Ran; Lin, Chao-Hsin; Liu, Junjie; Chen, Qingyan

    2015-02-01

    Indoor air distributions, such as the distributions of air temperature, air velocity, and contaminant concentrations, are very important to occupants' health and comfort in enclosed spaces. When point data is collected for interpolation to form field distributions, the sampling locations (the locations of the point sensors) have a significant effect on time invested, labor costs and measuring accuracy on field interpolation. This investigation compared two different sampling methods: the grid method and the gradient-based method, for determining sampling locations. The two methods were applied to obtain point air parameter data in an office room and in a section of an economy-class aircraft cabin. The point data obtained was then interpolated to form field distributions by the ordinary Kriging method. Our error analysis shows that the gradient-based sampling method has 32.6% smaller error of interpolation than the grid sampling method. We acquired the function between the interpolation errors and the sampling size (the number of sampling points). According to the function, the sampling size has an optimal value and the maximum sampling size can be determined by the sensor and system errors. This study recommends the gradient-based sampling method for measuring indoor air distributions.

  6. METHODS TO SAMPLE AIR BORNE PROPAGULES OF ASPERGILLUS FLAVUS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Several techniques (cyclone samplers, filter samplers and rotorods) were evaluated for detection of airborne Aspergillus flavus Link propagules in a cultivated region of southwest Arizona. Cyclone samplers operated continuously for 168 h (7 d) collected a dry sample that was ideal for quantificatio...

  7. A METHOD FOR THE SAMPLING AND ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) IN AMBIENT AIR

    EPA Science Inventory

    A method was developed for the sampling and analysis of polychlorinated biphenyls (PCBs) in air. An easily constructed, high-volume sampling system is employed with porous polyurethane foam as the collection medium. The sample is collected at the rate of 0.6 to 1.0 cu m per minut...

  8. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  9. COMPARISON OF FAST GC/TOFMS WITH METHOD TO-14 FOR ANALYSIS OF AMBIENT AIR SAMPLES

    EPA Science Inventory

    Field studies using portable gas chromatographs (PGC) to analyze volatile organic compounds in ambient air usually include, as reference standard method, the analysis of concurrent, collocated canister samples by EPA Method TO-14. Each laboratory analysis takes about an hour a...

  10. Evaluation of sampling and analytical methods for the determination of chlorodifluoromethane in air.

    PubMed

    Seymour, M J; Lucas, M F

    1993-05-01

    In January 1989, the Occupational Safety and Health Administration (OSHA) published revised permissible exposure limits (PELs) for 212 compounds and established PELs for 164 additional compounds. In cases where regulated compounds did not have specific sampling and analytical methods, methods were suggested by OSHA. The National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods (NMAM) Method 1020, which was developed for 1,1,2-trichloro-1,2,2-trifluoroethane, was suggested by OSHA for the determination of chlorodifluoromethane in workplace air. Because this method was developed for a liquid and chlorodifluoromethane is a gas, the ability of NMAM Method 1020 to adequately sample and quantitate chlorodifluoromethane was questioned and tested by researchers at NIOSH. The evaluation of NMAM Method 1020 for chlorodifluoromethane showed that the capacity of the 100/50-mg charcoal sorbent bed was limited, the standard preparation procedure was incorrect for a gas analyte, and the analyte had low solubility in carbon disulfide. NMAM Method 1018 for dichlorodifluoromethane uses two coconut-shell charcoal tubes in series, a 400/200-mg tube followed by a 100/50-mg tube, which are desorbed with methylene chloride. This method was evaluated for chlorodifluoromethane. Test atmospheres, with chlorodifluoromethane concentrations from 0.5-2 times the PEL were generated. Modifications of NMAM Method 1018 included changes in the standard preparation procedure, and the gas chromatograph was equipped with a capillary column. These revisions to NMAM 1018 resulted in a 96.5% recovery and a total precision for the method of 7.1% for chlorodifluoromethane. No significant bias in the method was found. Results indicate that the revised NMAM Method 1018 is suitable for the determination of chlorodifluoromethane in workplace air. PMID:8498360

  11. Method validation program for the long duration sampling of PCDDs/PCDFs in ambient air

    SciTech Connect

    Maisel, B.E.; Hunt, G.T.; Hoyt, M.P.; Rowe, N.; Scarfo, L.

    1994-12-31

    A method validation program was completed to assess the technical viability of extended, long duration sampling periods (15- and 30-day) for the collection of PCDDs/PCDFs in ambient air in lieu of the 48-hour sampling periods typically employed. This long duration approach, if successful, would provide measurements data more representative of average ambient PCDDs/PCDFs levels on an annual basis, and hence provide enhanced support of the 1.0 pg/m{sup 3} annual ambient standard for PCDDs/PCDFs (expressed at 1987 EPA toxic equivalents) required by Connecticut regulation. The method validation program utilized nine collocated PUF samplers which were operated for 15-day and 30-day periods during each of two seasonal monitoring campaigns (winter and summer). Samples were analyzed using high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) based on EPA Method 8290. Each PUF cartridge consisted of two foam halves; the top half PUF and filter were analyzed as a single sample separately from the bottom half PUF section. This approach provided an assessment of analyte breakthrough using the sampling system for large sample volumes of approximately 4,000 m{sup 3} and 8,000 m{sup 3} for the 15-day and respectively.

  12. Optimisation steps of an innovative air sampling method for semi volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Lazarov, Borislav; Swinnen, Rudi; Spruyt, Maarten; Goelen, Eddy; Stranger, Marianne; Desmet, Gilbert; Wauters, Eric

    2013-11-01

    This work describes optimisation steps of an innovative method for the measurement several groups of semi-volatile organic compounds (SVOCs) in air, collecting both gaseous and particulate air fractions. It is based on active air sampling on sorption tubes (consisting of polydimethylsiloxane (PDMS) and Tenax TA), followed by thermal desorption and gas chromatography mass spectrometry analysis (TD-GC-MS). The optimised method was validated in the laboratory for the measurement of selected target compounds from the following chemical classes: polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and phthalate esters (PEs). It was applied in different Belgian urban outdoor as well as indoor environments. The new method is characterised by limits of detection in the range of 0.003-0.3 ng m-3 for PAHs, 0.004-0.2 ng m-3 for PCBs, 0.113-0.201 ng m-3 for PBDEs and 0.002-0.2 ng m-3 for PEs, a linearity of 0.996 and a repeatability of less than 10% for all studied compounds.

  13. An evaluation of analytical methods, air sampling techniques, and airborne occupational exposure of metalworking fluids.

    PubMed

    Verma, Dave K; Shaw, Don S; Shaw, M Lorraine; Julian, Jim A; McCollin, Shari-Ann; des Tombe, Karen

    2006-02-01

    This article summarizes an assessment of air sampling and analytical methods for both oil and water-based metalworking fluids (MWFs). Three hundred and seventy-four long-term area and personal airborne samples were collected at four plants using total (closed-face) aerosol samplers and thoracic samplers. A direct-reading device (DustTrak) was also used. The processes sampled include steel tube making, automotive component manufacturing, and small part manufacturing in a machine shop. The American Society for Testing and Materials (ASTM) Method PS42-97 of analysis was evaluated in the laboratory. This evaluation included sample recovery, determination of detection limits, and stability of samples during storage. Results of the laboratory validation showed (a) the sample recovery to be about 87%, (b) the detection limit to be 35 microg, and (c) sample stability during storage at room temperature to decline rapidly within a few days. To minimize sample loss, the samples should be stored in a freezer and analyzed within a week. The ASTM method should be the preferred method for assessing metalworking fluids (MWFs). The ratio of thoracic aerosol to total aerosol ranged from 0.6 to 0.7. A similar relationship was found between the thoracic extractable aerosol and total extractable aerosol. The DustTrak, with 10-microm sampling head, was useful in pinpointing the areas of potential exposure. MWF exposure at the four plants ranged from 0.04 to 3.84 mg/m3 with the geometric mean ranging between 0.22 to 0.59 mg/m3. Based on this data and the assumption of log normality, MWF exposures are expected to exceed the National Institute for Occupational Safety and Health recommended exposure limit of 0.5 mg/m3 as total mass and 0.4 mg/m3 as thoracic mass about 38% of the time. In addition to controlling airborne MWF exposure, full protection of workers would require the institution of programs for fluid management and dermal exposure prevention. PMID:16361218

  14. A STRINGENT COMPARISON OF SAMPLING AND ANALYSIS METHODS FOR VOCS IN AMBIENT AIR

    EPA Science Inventory

    A carefully designed study was conducted during the summer of 1998 to simultaneously collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. A total of 32 1-h sample sets we...

  15. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings. PMID:27569522

  16. Evaluation of a modified sampling method for molecular analysis of air microflora.

    PubMed

    Lech, T; Ziembinska-Buczynska, A

    2015-01-01

    A serious issue concerning the durability of economically important materials for humans related to cultural heritage is the process of biodeterioration. As a result of this phenomenon, priceless works of art, documents, and old prints have undergone a process of decomposition caused by microorganisms. Therefore, it is important to constantly monitor the presence and diversity of microorganisms in exposition rooms and storage areas of historical objects. In addition, the use of molecular biology tools for conservation studies will enable detailed research as well as reduce the time needed to perform the analyses compared with using conventional methods related to microbiology and conservation. The aim of this study was to adapt the sampling indoor air method for direct DNA extraction from microorganisms, including evaluating the extracted DNA quality and concentration. The obtained DNA was used to study the diversity of mold fungi in indoor air using polymerase chain reaction-denaturing gradient gel electrophoresis in specific archives and museum environments. The research was conducted in 2 storage rooms of the National Archives in Krakow and in 1 exposition room of the Archaeological Museum in Krakow (Poland). PMID:25966086

  17. Uncertainties in Air Exchange using Continuous-Injection, Long-Term Sampling Tracer-Gas Methods

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.; Lunden, Melissa M.

    2013-12-01

    The PerFluorocarbon Tracer (PFT) method is a low-cost approach commonly used for measuring air exchange in buildings using tracer gases. It is a specific application of the more general Continuous-Injection, Long-Term Sampling (CILTS) method. The technique is widely used but there has been little work on understanding the uncertainties (both precision and bias) associated with its use, particularly given that it is typically deployed by untrained or lightly trained people to minimize experimental costs. In this article we will conduct a first-principles error analysis to estimate the uncertainties and then compare that analysis to CILTS measurements that were over-sampled, through the use of multiple tracers and emitter and sampler distribution patterns, in three houses. We find that the CILTS method can have an overall uncertainty of 10-15percent in ideal circumstances, but that even in highly controlled field experiments done by trained experimenters expected uncertainties are about 20percent. In addition, there are many field conditions (such as open windows) where CILTS is not likely to provide any quantitative data. Even avoiding the worst situations of assumption violations CILTS should be considered as having a something like a ?factor of two? uncertainty for the broad field trials that it is typically used in. We provide guidance on how to deploy CILTS and design the experiment to minimize uncertainties.

  18. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  19. Air Sampling Filter

    NASA Technical Reports Server (NTRS)

    1980-01-01

    General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

  20. Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.

    PubMed

    Woolfenden, Elizabeth

    2010-04-16

    Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents

  1. High-throughput liquid-absorption air-sampling apparatus and methods

    SciTech Connect

    2000-07-11

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is < 10 cm of water, usually < 5 cm of water. The sampler's collection efficiency is usually > 20% for vapors or airborne particulates in the 2--3 microns range and > 50% for particles larger than 4 microns. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  2. High-throughput liquid-absorption air-sampling apparatus and methods

    DOEpatents

    Zaromb, Solomon

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is <10 cm of water, usually <5 cm of water. The sampler's collection efficiency is usually >20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  3. Air sampling in the workplace. Final report

    SciTech Connect

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC`s Regulatory Guide 8.25, Revision 1, ``Air sampling in the Workplace.`` That guide addresses air sampling to meet the requirements in NRC`s regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed.

  4. An analytical method for trifluoroacetic Acid in water and air samples using headspace gas chromatographic determination of the methyl ester.

    PubMed

    Zehavi, D; Seiber, J N

    1996-10-01

    An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA. PMID:21619278

  5. Thermal desorption-gas chromatography-mass spectrometry method to determine phthalate and organophosphate esters from air samples.

    PubMed

    Aragón, M; Borrull, F; Marcé, R M

    2013-08-16

    A method based on thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) has been developed to determine four organophosphate esters, seven phthalate esters, and bis(2-ethylhexyl) adipate in the gas phase from harbour and urban air samples. The method involves the sampling of 1.5L of air in a Tenax TA sorbent tube followed by thermal desorption (using a Tenax TA cryogenic trap) coupled to gas chromatography-mass spectrometry. The repeatability of the method expressed as %RSD (n=3) is less than 15% and the MQLs are between 0.007μgm(-3) (DMP, TBP, BBP, TPP and DnOP) and 6.7μgm(-3) (DEHP). The method was successfully applied in two areas (urban and harbour) testing two and three points in each one, respectively. Some of these compounds were found in both urban and harbour samples. Di-(2-ethylhexyl)phthalate was the most abundant compound found in both areas at concentration levels between 6.7μgm(-3) and 136.4μgm(-3). This study demonstrates that thermal desorption is an efficient method for the determination of these semi-volatile compounds in the gas phase fraction of air samples. PMID:23859797

  6. Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

    PubMed

    Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud

    2016-03-01

    Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments. PMID:26491105

  7. Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air

    SciTech Connect

    Harless, R.L.; Lewis, R.G.; McDaniel, D.D.; Gibson, J.F.; Dupuy, A.E.

    1992-01-01

    General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenz-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cubic meter ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C-12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cubic meter and sub-pg/cubic meter levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured.

  8. A sensitive LC-MS/MS method for measurement of organophosphorus pesticides and their oxygen analogs in air sampling matrices.

    PubMed

    Armstrong, Jenna L; Dills, Russell L; Yu, Jianbo; Yost, Michael G; Fenske, Richard A

    2014-01-01

    A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of levels of the organophosphorus (OP) pesticides chlorpyrifos (CPF), azinphos methyl (AZM), and their oxygen analogs chlorpyrifos-oxon (CPF-O) and azinphos methyl-oxon (AZM-O) on common active air sampling matrices. XAD-2 resin and polyurethane foam (PUF) matrices were extracted with acetonitrile containing stable-isotope labeled internal standards (ISTD). Analysis was accomplished in Multiple Reaction Monitoring (MRM) mode, and analytes in unknown samples were identified by retention time (±0.1 min) and qualifier ratio (±30% absolute) as compared to the mean of calibrants. For all compounds, calibration linearity correlation coefficients were ≥0.996. Limits of detection (LOD) ranged from 0.15-1.1 ng/sample for CPF, CPF-O, AZM, and AZM-O on active sampling matrices. Spiked fortification recoveries were 78-113% from XAD-2 active air sampling tubes and 71-108% from PUF active air sampling tubes. Storage stability tests also yielded recoveries ranging from 74-94% after time periods ranging from 2-10 months. The results demonstrate that LC-MS/MS is a sensitive method for determining these compounds from two different matrices at the low concentrations that can result from spray drift and long range transport in non-target areas following agricultural applications. In an inter-laboratory comparison, the limit of quantification (LOQ) for LC-MS/MS was 100 times lower than a typical gas chromatography-mass spectrometry (GC-MS) method. PMID:24328542

  9. Long-term measurement of volatile organic compounds in ambient air by canister-based one-week sampling method.

    PubMed

    Ochiai, Nobuo; Daishima, Shigeki; Cardin, Daniel B

    2003-12-01

    A canister-based 1 week sampling method using a mechanical flow controller and a 6 L fused-silica-lined canister was evaluated for the long-term measurement of 47 VOCs in ambient air at pptv (volume/volume) to ppbv levels by use of a three-stage preconcentation method followed by GC-MS analysis. The GC conditions were initially optimized for complete separations of several pptv-level VOCs (e.g. vinyl chloride, 1,3-butadiene, acrylonitrile, 1,2-dichloroethane and chloroform) in ambient air because the selected ions are easily interfered with by coexisting C4-, C5-hydrocarbons and analytes presented at ppbv levels. Thirty-four VOCs determined by the 1 week and 24 h sampling method in December 16-22 (2002) had concentrations of 6.0-15000 pptv per compound. Concentrations of 28 VOCs (including polar VOCs (e.g. methyl isobutyl ketone and butyl acetate)) obtained by the method were approximately equal to the mean values calculated from 24 h sampling (< +/- 10% deviation). Six VOCs that had low concentrations of 6.0-43 pptv showed more than +/- 10% deviation. Thirteen VOCs were not detected during the entire sampling period. The effect of relative humidity or ozone for the specific VOCs (e.g. MIBK, butyl acetate, vinyl chloride, 1,3-butadiene and styrene) was negligible. PMID:14710945

  10. Improved Sampling Method Reduces Isokinetic Sampling Errors.

    ERIC Educational Resources Information Center

    Karels, Gale G.

    The particulate sampling system currently in use by the Bay Area Air Pollution Control District, San Francisco, California is described in this presentation for the 12th Conference on Methods in Air Pollution and Industrial Hygiene Studies, University of Southern California, April, 1971. The method represents a practical, inexpensive tool that can…

  11. Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air

    SciTech Connect

    Harless, R.L.; Lewis, R.G.; McDaniel, D.D.; Gibson, J.F.; Dupuy, A.E.

    1991-01-01

    General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C12-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cu m ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cu m and sub-pg/cu m levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured. Background levels of these compounds in the ambient air were also determined. Total PCDDs, PCDFs, TBDFs, and PeBDFs were detected in a low concentration range of 0.3 to 3.0 pg/cu m.

  12. Comparison of different sampling methods for the determination of low-level radionuclides in air.

    PubMed

    Duch, Ma; Serrano, I; Cabello, V; Camacho, A

    2016-03-01

    The aim of this work is to check the consistency of results given by different air dust samplers (flow-rates between 2 and 700m(3)/h) and measurement protocols at a single location. The study is focussed on (210)Pb since is the only nuclide that can be easily assessed through all the studied sampler types. Results from high- and mid-volume samplers agreed well to within the associated uncertainties. Gross beta activity from low-volume samplers can be used as a good indicator of the evolution of (210)Pb concentration in air. PMID:26631453

  13. DEVELOPMENT OF AN ANALYTICAL METHOD FOR THE DETERMINATION OF QUINCLORAC (FACET) IN AIR SAMPLES

    EPA Science Inventory

    Quinclorac (Facet) is a herbicide used on rice crops. Tomato farmers were concerned that aerial spraying of this herbicide was damaging their crops. The University of Arkansas initiated a study of air, soil, and plant material to see if this herbicide had entered these tomato f...

  14. Procedures manual for the recommended ARB (Air Resources Board) sized chemical sample method (cascade cyclones)

    SciTech Connect

    McCain, J.D.; Dawes, S.S.; Farthing, W.E.

    1986-05-01

    The report is Attachment No. 2 to the Final Report of ARB Contract A3-092-32 and provides a tutorial on the use of Cascade (Series) Cyclones to obtain size-fractionated particulate samples from industrial flue gases at stationary sources. The instrumentation and procedures described are designed to protect the purity of the collected samples so that post-test chemical analysis may be performed for organic and inorganic compounds, including instrumental analysis for trace elements. The instrumentation described collects bulk quantities for each of six size fractions over the range 10 to 0.4 micrometer diameter. The report describes the operating principles, calibration, and empirical modeling of small cyclone performance. It also discusses the preliminary calculations, operation, sample retrieval, and data analysis associated with the use of cyclones to obtain size-segregated samples and to measure particle-size distributions.

  15. Field comparison of air sampling methods for monomeric and polymeric 1,6-hexamethylene diisocyanate.

    PubMed

    Thomasen, Jennifer M; Fent, Kenneth W; Reeb-Whitaker, Carolyn; Whittaker, Stephen G; Nylander-French, Leena A

    2011-03-01

    This study was to critically compared 13 different air samplers for their ability to monitor air exposures to monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI) in the automotive refinishing industry. Using both fast- and slow-drying clearcoat, we tested the following types of samplers: single- and dual-stage 37-mm polypropylene (PP) and polystyrene (PS) samplers (open- and closed-face), IOM (with plastic and stainless steel inserts), OSHA42, IsoChek, and WA-DOSH samplers. Midget impingers with frit were used as reference samplers. We observed the PP, PS, and IOM samplers to measure greater levels of HDI monomer and biuret when a fast-drying clearcoat was applied compared with a slow-drying clearcoat. When a slow-drying clearcoat was applied, the open-face PP and PS samplers measured significantly more monomeric and polymeric HDI (2-fold; p < 0.003) than the closed-face PP and PS samplers. We determined that significantly more monomeric and polymeric HDI were measured by impingers (1.3-1.9-fold) compared with single-stage PP/PS (N = 59), dual-stage PP/PS (N = 59), or IOM (N = 24) samplers. However, when stratified by cassette characteristics, the open-face single-stage PP and PS samplers performed equally to the impingers for HDI monomer when a fast-drying clearcoat was applied, and for all analytes when a slow-drying clearcoat was applied. Significantly higher HDI monomer concentrations (1.2-3.1-fold; p = 0.001) were measured with OSHA42 compared with the impinger. The IsoChek did not detect HDI monomer, and of the three samplers analyzed by laboratories other than UNC (i.e., OSHA42, IsoChek, and WA-DOSH), the WA-DOSH was in the best agreement with the impingers. The influence of clearcoat drying time on the sampler's ability to measure monomeric and polymeric HDI emphasizes the importance of the speciation of diisocyanates in chemical analysis and the careful consideration for the selection of the air sampler to be used when measuring exposures during

  16. Auditing of sampling methods for air toxics at coal-fired power plants

    SciTech Connect

    Agbede, R.O.; Clements, J.L.; Grunebach, M.G.

    1995-11-01

    Advanced Technology Systems, Inc. (ATS) with subcontract assistance from international Technology Corporation (IT) has provided external audit activities for Phase II of the Department of Energy-Pittsburgh Energy Technology Center`s air emission test program. The objective of the audits is to help ensure that the data obtained from the emission tests are precise, accurate, representative, scientifically sound and legally defensible. This paper presents the criteria that were used to perform the external audits of the emission test program. It also describes the approach used by ATS and It in performing their audits. Examples of findings of the audits along with the actions take to correct problems and the subsequent effect of those actions on the test data are presented. The results of audit spikes performed at the Plant 1 test site are also discussed.

  17. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1987-12-10

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  18. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, Katharine H.

    1990-01-01

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

  19. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1990-05-22

    An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  20. Development of Methods for Sampling and Analysis of Polychlorinated Naphthalenes in Ambient Air

    ERIC Educational Resources Information Center

    Erickson, Mitchell D.; And Others

    1978-01-01

    The procedure and sampler described permits detection of less than 50pg of one polychlorinated naphthalene (PCN) isomer. The method uses gas chromatography-mass spectrometry. The PCNs are collected on a glass fiber filter and two polyurethane foam plugs and extracted with toluene at 25 degrees Celsius. (BB)

  1. Methods for polynuclear aromatic hydrocarbon determination in air samples using polar-bonded phase HPLC and GC-MS with application to oil refinery samples

    SciTech Connect

    Karlesky, K.L.

    1985-01-01

    Particle samples were collected using high volume air samplers fitted with glass fiber filters or with a cascade impactor containing paper filters. They were then cleaned using either extraction with dimethylsulfoxide and pentane or utilizing a small cartridge containing a diamine polar-bonded phase material, the second method being more effective. Vapor phase PAH were sampled using an apparatus designed in the laboratory. After collection, the resins were desorbed with solvent and the PAH content was determined. The suitability of the resins decrease in the following order: Amberlite XAD-2, Chromosorb 105, Tenax GC, coconut charcoal, and Ambesorb XE-348. High performance liquid chromatography (HPLC) was used to determine the behavior of PAH in the normal and reversed phase on polar-bonded phases containing amine, diamine, and pyrrolidone substrates. Results support the proposed mechanism in the normal phase and indicate that both a partitioning and liquid-solid adsorption mechanism takes place in the reversed phase depending upon the mobile phase. Occasionally, these polar-bonded phases can be deactivated by the formation of amine-carbonyl complexes from polar aldehydes or ketones in the solvent or sample. Deactivation can be reversed by flushing with water to hydrolyze the Schiff's base imine back to the amine. Gas chromatography-mass spectroscopy (GC-MS) was used to analyze air samples from oil refineries in Port Arthur, collected over a period of three years. The analytical procedures are applied to the collected samples to determine if they contain detectable amounts of PAH. The GC-MS analysis was adequate for this study but the use of SIM detection is preferred because of the greater sensitivity for PAH.

  2. Air sampling with solid phase microextraction

    NASA Astrophysics Data System (ADS)

    Martos, Perry Anthony

    There is an increasing need for simple yet accurate air sampling methods. The acceptance of new air sampling methods requires compatibility with conventional chromatographic equipment, and the new methods have to be environmentally friendly, simple to use, yet with equal, or better, detection limits, accuracy and precision than standard methods. Solid phase microextraction (SPME) satisfies the conditions for new air sampling methods. Analyte detection limits, accuracy and precision of analysis with SPME are typically better than with any conventional air sampling methods. Yet, air sampling with SPME requires no pumps, solvents, is re-usable, extremely simple to use, is completely compatible with current chromatographic equipment, and requires a small capital investment. The first SPME fiber coating used in this study was poly(dimethylsiloxane) (PDMS), a hydrophobic liquid film, to sample a large range of airborne hydrocarbons such as benzene and octane. Quantification without an external calibration procedure is possible with this coating. Well understood are the physical and chemical properties of this coating, which are quite similar to those of the siloxane stationary phase used in capillary columns. The log of analyte distribution coefficients for PDMS are linearly related to chromatographic retention indices and to the inverse of temperature. Therefore, the actual chromatogram from the analysis of the PDMS air sampler will yield the calibration parameters which are used to quantify unknown airborne analyte concentrations (ppb v to ppm v range). The second fiber coating used in this study was PDMS/divinyl benzene (PDMS/DVB) onto which o-(2,3,4,5,6- pentafluorobenzyl) hydroxylamine (PFBHA) was adsorbed for the on-fiber derivatization of gaseous formaldehyde (ppb v range), with and without external calibration. The oxime formed from the reaction can be detected with conventional gas chromatographic detectors. Typical grab sampling times were as small as 5 seconds

  3. Evaluation of sampling methods for measuring exposure to volatile inorganic acids in workplace air. Part 2: Sampling capacity and breakthrough tests for sodium carbonate-impregnated filters.

    PubMed

    Demange, Martine; Oury, Véronique; Rousset, Davy

    2011-11-01

    In France, the MétroPol 009 method used to measure workplace exposure to inorganic acids, such as HF, HCl, and HNO3, consists of a closed-face cassette fitted with a prefilter to collect particles, and two sodium carbonate-impregnated filters to collect acid vapor. This method was compared with other European methods during the development of a three-part standard (ISO 21438) on the determination of inorganic acids in workplace air by ion chromatography. Results of this work, presented in a companion paper, led to a need to go deeper into the performance of the MétroPol 009 method regarding evaluation of the breakthrough of the acids, both alone and in mixtures, interference from particulate salts, the amount of sodium carbonate required to impregnate the sampling filter, the influence of sampler components, and so on. Results enabled improvements to be made to the sampling device with respect to the required amount of sodium carbonate to sample high HCl or HNO3 concentrations (500 μL of 5% Na2CO3 on each of two impregnated filters). In addition, a PVC-A filter used as a prefilter in a sampling device showed a propensity to retain HNO3 vapor so a PTFE filter was considered more suitable for use as a prefilter. Neither the material of the sampling cassette (polystyrene or polypropylene) nor the sampling flowrate (1 L/min or 2 L/min) influenced the performance of the sampling device, as a recovery of about 100% was achieved in all experiments for HNO3, HCl, and HF, as well as HNO3+HF and HNO3+HCl mixtures, over a wide range of concentrations. However, this work points to the possibility of interference between an acid and salts of other acids. For instance, interference can occur through interaction of HNO3 with chloride salts: the stronger the acid, the greater the interference. Methods based on impregnated filters are reliable for quantitative recovery of inorganic volatile acids in workplace atmosphere but are valuable only in the absence of interferents. PMID

  4. Air Sampling System Evaluation Template

    2000-05-09

    The ASSET1.0 software provides a template with which a user can evaluate an Air Sampling System against the latest version of ANSI N13.1 "Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities". The software uses the ANSI N13.1 PIC levels to establish basic design criteria for the existing or proposed sampling system. The software looks at such criteria as PIC level, type of radionuclide emissions, physical state ofmore » the radionuclide, nozzle entrance effects, particulate transmission effects, system and component accuracy and precision evaluations, and basic system operations to provide a detailed look at the subsystems of a monitoring and sampling system/program. A GAP evaluation can then be completed which leads to identification of design and operational flaws in the proposed systems. Corrective measures can then be limited to the GAPs.« less

  5. DETECTING WASTE COMBUSTION EMISSIONS: SEVERAL ADVANCED METHODS ARE USEFUL FOR SAMPLING AIR CONTAMINANTS FROM HAZARDOUS WASTE INCINERATOR STACKS

    EPA Science Inventory

    The paper is an overview of sampling methods being recommended to EPA regulatory programs, to EPA engineering research and development projects, and to interested parties in the industrial community. The methods discussed are generally applicable to both incineration and processe...

  6. EVALUATION OF A SAMPLING AND ANALYSIS METHOD FOR DETERMINATION OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN AMBIENT AIR

    EPA Science Inventory

    General Metals Works PS-1 PUF air samplers and an analytical method based on high esolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were valuated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibe...

  7. Sampling of trace volatile metal(loid) compounds in ambient air using polymer bags: a convenient method.

    PubMed

    Haas, K; Feldmann, J

    2000-09-01

    The sampling of volatile metal(loid) compounds (VOMs) such as hydrides, methylated, and permethylated species of arsenic, antimony, and tin is described using Tedlar bags. Advantages as well as limitations and constraints are discussed and compared to other widely used sampling techniques within this area, namely, stainless steel canisters, cryotrapping, and solid adsorbent cartridges. To prove the suitability of Tedlar bags for the sampling of volatile metal(loid) compounds, series of stability tests have been run using both laboratory synthetic and real samples analyzed periodically after increasing periods of storage. The samples have been stored in the dark at 20 degrees C and at 50 degrees C. Various volatile arsenic species (AsH3, MeAsH2, Me2AsH, Me3As), tin species (SnH4, MeSnH3, Me2SnH2, Me3SnH, Me4Sn, BuSnH3), and antimony species (SbH3, MeSbH2, Me2SbH, Me3Sb) have been generated using hydride generation methodology and mixed with moisturized air. Three static gaseous atmospheres with concentrations of 0.3-18 ng/L for the various compounds have been generated in Tedlar bags, and the stability of the VOMs has been monitored over a period of 5 weeks. Sewage sludge digester gas samples have been stored only at 20 degrees C for a period of 48 h. Cryotrapping GC/ICPMS has been used for the determination of the VOMs with a relative standard deviation of 5% for 100 pg. After 8 h, the recovery rate of all the compounds in the air atmospheres was better than 95% at 20 and 50 degrees C, whereas the recovery after 24 h was found to be between 81 and 99% for all VOMs at 20 and 50 degrees C except for Me3Sb and Me3As. These species show a loss between 48 and 73% at both temperatures. After 5 weeks at 20 degrees C, a loss of only 25-50% for arsine and stibine and the above-mentioned tin compounds was determined. Only Me3Sb, Me3Bi, and Me2Te were present in the digester gas sample. After 24 h, losses of 44, 10, and 12%, respectively, could be determined. Given these

  8. Development of a sampling and analytical method for 2,2-dichloro-1,1,1-trifluoroethane in workplace air.

    PubMed

    Shin, Yong Chul; Yi, Gwang Yong; Kim, Yangho; Paik, Nam Won

    2002-01-01

    The use of 2,2-dichloro-1,1,1-trifluoroethane (compound number: HCFC-123) is growing in industry as a substitute for ozone-depleting chlorofluorocarbons (CFCs). Recently, liver-related illnesses have been reported from industries handling HCFC-123. However, information on worker exposure to the material is limited, and an acceptable sampling/analytical method is not available. The aim of this study was to develop a widely applicable sampling and analytical method to determine worker exposures to airborne HCFC-123 and to evaluate the performance of the method. A solid sorbent tube, containing two sections (400 mg in the front and 200 mg in the back) of activated coconut-shell charcoal was chosen for sampling airborne HCFC-123 vapor. The breakthrough volumes were 13.6 L at 3597 +/- 210.1 ppm (with a sampling airflow rate of 0.046 L/min) and 17.0 L at 1841 +/- 4.5 ppm (with sampling airflow rate of 0.046-0.050 L/min). Samples of HCFC-123 in the charcoal tube were stable for 7 days either at room temperature or in a refrigerator and a migration occurred within 14 days at room temperature. It is recommended that the HCFC-123 sample in activated charcoal tubes be stored either at room temperature or in a refrigerator and be analyzed within 7 days. The HCFC-123 in the charcoal tubes was desorbed into dichloromethane and analyzed using gas chromatography/ flame ionization detection. The limit of detection was 0.23 mg/sample, and the average desorption efficiency was 99.0%. The total coefficient of variation was 0.060, and the method accuracy was 16.6%. In conclusion, the performance of the sampling and analytical method developed for the determination of airborne HCFC-123 concentrations was acceptable to the NIOSH sampling and analytical criteria. PMID:12570079

  9. Analytical method validation for the determination of 2,3,3,3-tetrafluoropropene in air samples using gas chromatography with flame ionization detection.

    PubMed

    Mawn, Michael P; Kurtz, Kristine; Stahl, Deborah; Chalfant, Richard L; Koban, Mary E; Dawson, Barbara J

    2013-01-01

    A new low global warming refrigerant, 2,3,3,3-tetrafluoro propene, or HFO-1234yf, has been successfully evaluated for automotive air conditioning, and is also being evaluated for stationary refrigeration and air conditioning systems. Due to the advantageous environmental properties of HFO-1234yf versus HFC-134a, coupled with its similar physical properties and system performance, HFO-1234yf is also being evaluated to replace HFC-134a in refrigeration applications where neat HFC-134a is currently used. This study reports on the development and validation of a sampling and analytical method for the determination of HFO-1234yf in air. Different collection media were screened for desorption and simulated sampling efficiency with three-section (350/350/350 mg) Anasorb CSC showing the best results. Therefore, air samples were collected using two 3-section Anasorb CSC sorbent tubes in series at 0.02 L/min for up to 8 hr for sample volumes of up to 9.6 L. The sorbent tubes were extracted in methylene chloride, and analyzed by gas chromatography with flame ionization detection. The method was validated from 0.1× to 20× the target level of 0.5 ppm (2.3 mg/m(3)) for a 9.6 L air volume. Desorption efficiencies for HFO-1234yf were 88 to 109% for all replicates over the validation range with a mean overall recovery of 93%. Simulated sampling efficiencies ranged from 87 to 104% with a mean of 94%. No migration or breakthrough to the back tube was observed under the sampling conditions evaluated. HFO-1234yf samples showed acceptable storage stability on Anasorb CSC sorbent up to a period of 30 days when stored under ambient, refrigerated, or frozen temperature conditions. PMID:24116663

  10. EVALUATION OF A METHOD FOR SAMPLING AND ANALYSIS OF NICOTINE AND POLYNUCLEAR AROMATIC HYDROCARBONS IN INDOOR AIR

    EPA Science Inventory

    A study was performed to determine whether one sampling system and one analytical method can be used to measure both polynuclear aromatic hydrocarbons (PAH) and nicotine. he PAH collection efficiencies for both XAD-2 and XAD-4 adsorbents are very similar, but the nicotine collect...

  11. Comparison of passive diffusion bag samplers and submersible pump sampling methods for monitoring volatile organic compounds in ground water at Area 6, Naval Air Station, Whidbey Island, Washington

    USGS Publications Warehouse

    Huffman, Raegan L.

    2002-01-01

    Ground-water samples were collected in April 1999 at Naval Air Station Whidbey Island, Washington, with passive diffusion samplers and a submersible pump to compare concentrations of volatile organic compounds (VOCs) in water samples collected using the two sampling methods. Single diffusion samplers were installed in wells with 10-foot screened intervals, and multiple diffusion samplers were installed in wells with 20- to 40-foot screened intervals. The diffusion samplers were recovered after 20 days and the wells were then sampled using a submersible pump. VOC concentrations in the 10-foot screened wells in water samples collected with diffusion samplers closely matched concentrations in samples collected with the submersible pump. Analysis of VOC concentrations in samples collected from the 20- to 40-foot screened wells with multiple diffusion samplers indicated vertical concentration variation within the screened interval, whereas the analysis of VOC concentrations in samples collected with the submersible pump indicated mixing during pumping. The results obtained using the two sampling methods indicate that the samples collected with the diffusion samplers were comparable with and can be considerably less expensive than samples collected using a submersible pump.

  12. Development of air sampling and analytical methods for toxic chlorinated organic compounds. Research report for 1,2-dichloropropane

    SciTech Connect

    Dillon, H.K.; Boyd, K.W.; Emory, M.B.

    1980-06-11

    Sampling and analytical methods for determining 1,2-dichloropropane (78875) (1,2-DCP) were evaluated. Detectors and columns were tested for suitability for chromatographic analysis. Various charcoals and other sorbents were tested for their capacity and desorption efficiency. An independent continuous organic vapor monitor was used to determine concentrations during the sampling studies. Petroleum charcoal was the most efficient collection medium, and acetone in cyclohexane was the most efficient desorbant. Gas chromatography with electrolytic conductivity was efficient for analysis. In tests over the concentration range of 0.124 to 128 milligrams per cubic meter, 1,2-DCP, the combination of petroleum charcoal, acetone in cyclohexane, and gas chromatography provided a 6.4% deviation for repeated measurements. Average recovery was 100%.

  13. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  14. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  15. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  16. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  17. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  18. Sampling system and method

    DOEpatents

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  19. Development and validation of a sensitive thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) method for the determination of phosgene in air samples.

    PubMed

    Juillet, Y; Dubois, C; Bintein, F; Dissard, J; Bossée, A

    2014-08-01

    A new rapid, sensitive and reliable method was developed for the determination of phosgene in air samples using thermal desorption (TD) followed by gas chromatography-mass spectrometry (GC-MS). The method is based on a fast (10 min) active sampling of only 1 L of air onto a Tenax® GR tube doped with 0.5 mL of derivatizing mixture containing dimercaptotoluene and triethylamine in hexane solution. Validation of the TD-GC-MS method showed a low limit of detection (40 ppbv), acceptable repeatability, intermediate fidelity (relative standard deviation within 12 %) and excellent accuracy (>95%). Linearity was demonstrated for two concentration ranges (0.04 to 2.5 ppmv and 2.5 to 10 ppmv) owing to variation of derivatization recovery between low and high concentration levels. Due to its simple on-site implementation and its close similarity with recommended operating procedure (ROP) for chemical warfare agents vapour sampling, the method is particularly useful in the process of verification of the Chemical Weapons Convention. PMID:24817348

  20. New Spectrophotometric Method for Determining Nitrogen Dioxide in Air Using 2,2-azino-bis(3-ethyl benzothiazoline)-6-Sulfonic Acid-Diammonium Salt and Passive Sampling

    PubMed Central

    Salem, Alaa A.; Soliman, Ahmed A.; El-Haty, Ismail A.

    2011-01-01

    A new simple and highly sensitive spectrophotometric method for determining nitrogen dioxide in air was developed. The method is based on converting atmospheric nitrogen dioxide to nitrite ions within the IVL passive samplers used for samples collection. Acidifying nitrite ions with concentrated HCl produced the peroxynitrous acid oxidizing agent which was measured using 2, 2-azino-bis(3-ethyl benzothiazoline)-6-sulfonic acid-diammonium salt (ABTS) as reducing coloring agent. A parallel series of collected samples were measured for its nitrite content using a validated ion chromatographic method. The results obtained using both methods were compared in terms of their sensitivity and accuracy. Developed spectrophotometric method was shown to be one order of magnitude higher in sensitivity compared to the ion chromatographic method. Quantitation limits of 0.05 ppm and 0.55 μg/m3 were obtained for nitrite ion and nitrogen dioxid, respectively. Standard deviations in the ranges of 0.05–0.59 and 0.63–7.92 with averages of 0.27 and 3.11 were obtained for determining nitrite and nitrogen dioxide, respectively. Student-t test revealed t-values less than 6.93 and 4.40 for nitrite ions and nitrogen dioxide, respectively. These values indicated insignificant difference between the averages of the newly developed method and the values obtained by ion chromatography at 95% confidence level. Compared to continuous monitoring techniques, the newly developed method has shown simple, accurate, sensitive, inexpensive and reliable for long term monitoring of nitrogen dioxide in ambient air. PMID:21760708

  1. Evaluation of sampling methods for measuring exposure to volatile inorganic acids in workplace air. Part 1: sampling hydrochloric acid (HCl) and nitric acid (HNO₃) from a test gas atmosphere.

    PubMed

    Howe, Alan; Musgrove, Darren; Breuer, Dietmar; Gusbeth, Krista; Moritz, Andreas; Demange, Martine; Oury, Véronique; Rousset, Davy; Dorotte, Michel

    2011-08-01

    Historically, workplace exposure to the volatile inorganic acids hydrochloric acid (HCl) and nitric acid (HNO(3)) has been determined mostly by collection on silica gel sorbent tubes and analysis of the corresponding anions by ion chromatography (IC). However, HCl and HNO(3) can be present in workplace air in the form of mist as well as vapor, so it is important to sample the inhalable fraction of airborne particles. As sorbent tubes exhibit a low sampling efficiency for inhalable particles, a more suitable method was required. This is the first of two articles on "Evaluation of Sampling Methods for Measuring Exposure to Volatile Inorganic Acids in Workplace Air" and describes collaborative sampling exercises carried out to evaluate an alternative method for sampling HCl and HNO(3) using sodium carbonate-impregnated filters. The second article describes sampling capacity and breakthrough tests. The method was found to perform well and a quartz fiber filter impregnated with 500 μL of 1 M Na(2)CO(3) (10% (m/v) Na(2)CO(3)) was found to have sufficient sampling capacity for use in workplace air measurement. A pre-filter is required to remove particulate chlorides and nitrates that when present would otherwise result in a positive interference. A GSP sampler fitted with a plastic cone, a closed face cassette, or a plastic IOM sampler were all found to be suitable for mounting the pre-filter and sampling filter(s), but care has to be taken with the IOM sampler to ensure that the sampler is tightly closed to avoid leaks. HCl and HNO(3) can react with co-sampled particulate matter on the pre-filter, e.g., zinc oxide, leading to low results, and stronger acids can react with particulate chlorides and nitrates removed by the pre-filter to liberate HCl and HNO(3), which are subsequently collected on the sampling filter, leading to high results. However, although there is this potential for both positive and negative interferences in the measurement, these are unavoidable

  2. Evaluation of sampling and analytical methods for nicotine and polynuclear aromatic hydrocarbon in indoor air. Final report, 1 February 1987-30 March 1987

    SciTech Connect

    Chuang, J.C.; Kuhlman, M.R.; Hannan, S.W.; Bridges, C.

    1987-11-01

    The objective of this project was to evaluate a potential collection medium, XAD-4 resin, for collecting nicotine and polynuclear aromatic hydrocarbon (PAH) and to determine whether one collection system and one analytical method will allow quantification of both compound classes in air. The extraction efficiency study was to determine the extraction method to quantitatively remove nicotine and PAH from XAD-4 resin. The results showed that a two-step Soxhlet extraction consisting of dichloromethane followed by ethyl acetate resulted in the best recoveries for both nicotine and PAH. In the sampling efficiency study, XAD-2 and XAD-4 resin were compared, in parallel, for collection of PAH and nicotine. Quartz fiber filters were placed upstream of both adsorbents to collect particles. Prior to sampling, both XAD-2 and XAD-4 traps were spiked with known amounts (2 microgram) of perdeuterated PAH and D3-nicotine. The experiments were performed with cigarette smoking and nonsmoking conditions. The spiked PAH were retained well in both adsorbents after exposure to more than 300 cu. m. of indoor air. The spiked XAD-4 resin gave higher recoveries for D3-nicotine than did the spiked XAD-2 resin. The collection efficiency for PAH for both adsorbents is very similar but higher levels of nicotine were collected on XAD-4 resin.

  3. Carbonaceous species methods comparison study at Citrus College. Task: analysis for trace hydrocarbons and related halocarbons in urban ambient air samples. Final report

    SciTech Connect

    Rasmussen, R.A.

    1987-10-01

    As part of the ARB-sponsored Carbonaceous Species Methods Comparison Study (CSMCS) in Glendora, CA, from August 11-21, 1986, time-integrated, ambient samples were collected in stainless steel canisters. Five samples per day were collected, ranging from 4 to 8 hours according to the CSMCS protocol. The species measured included CO, CH/sub 4/, CO/sub 2/, H/sub 2/, and the C/sub 2/ through C10 hydrocarbons. In addition, N/sub 2/O, the halocarbons F-12, F-11, F-113, CHCl/sub 3/, CH/sub 3/CCl/sub 3/, CCl/sub 4/, C/sub 2/HCl/sub 3/ and C/sub 2/Cl/sub 4/ were measured. Four gas-chromatograph systems were used to quantify these species. The report contains tables of concentrations of the species measured at the South Coast Air Basin site during smoggy summer conditions.

  4. East Mountain Area 1995 air sampling results

    SciTech Connect

    Deola, R.A.

    1996-09-01

    Ambient air samples were taken at two locations in the East Mountain Area in conjunction with thermal testing at the Lurance Canyon Burn Site (LCBS). The samples were taken to provide measurements of particulate matter with a diameter less than or equal to 10 micrometers (PM{sub 10}) and volatile organic compounds (VOCs). This report summarizes the results of the sampling performed in 1995. The results from small-scale testing performed to determine the potentially produced air pollutants in the thermal tests are included in this report. Analytical results indicate few samples produced measurable concentrations of pollutants believed to be produced by thermal testing. Recommendations for future air sampling in the East Mountain Area are also noted.

  5. Interlaboratory evaluation of a standardized inductively coupled plasma mass spectrometry method for the determination of trace beryllium in air filter samples.

    PubMed

    Ashley, Kevin; Brisson, Michael J; Howe, Alan M; Bartley, David L

    2009-12-01

    A collaborative interlaboratory evaluation of a newly standardized inductively coupled plasma mass spectrometry (ICP-MS) method for determining trace beryllium in workplace air samples was carried out toward fulfillment of method validation requirements for ASTM International voluntary consensus standard test methods. The interlaboratory study (ILS) was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Uncertainty was also estimated in accordance with ASTM D7440, which applies the International Organization for Standardization Guide to the Expression of Uncertainty in Measurement to air quality measurements. Performance evaluation materials (PEMs) used consisted of 37 mm diameter mixed cellulose ester filters that were spiked with beryllium at levels of 0.025 (low loading), 0.5 (medium loading), and 10 (high loading) microg Be/filter; these spiked filters were prepared by a contract laboratory. Participating laboratories were recruited from a pool of over 50 invitees; ultimately, 20 laboratories from Europe, North America, and Asia submitted ILS results. Triplicates of each PEM (blanks plus the three different loading levels) were conveyed to each volunteer laboratory, along with a copy of the draft standard test method that each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the PEMs by one of three sample preparation procedures (hotplate or microwave digestion or hotblock extraction) that were described in the draft standard. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS and to report their data in units of mu g Be/filter sample. Interlaboratory precision estimates from participating laboratories, computed in accordance with ASTM E691, were 0.165, 0.108, and 0.151 (relative standard deviation) for the PEMs spiked at 0.025, 0

  6. Evaluating Radionuclide Air Emission Stack Sampling Systems

    SciTech Connect

    Ballinger, Marcel Y.

    2002-12-16

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R&D) facilities for the U.S. Department of Energy at the Hanford Site, Washington. These facilities are subject to Clean Air Act regulations that require sampling of radionuclide air emissions from some of these facilities. A revision to an American National Standards Institute (ANSI) standard on sampling radioactive air emissions has recently been incorporated into federal and state regulations and a re-evaluation of affected facilities is being performed to determine the impact. The revised standard requires a well-mixed sampling location that must be demonstrated through tests specified in the standard. It also carries a number of maintenance requirements, including inspections and cleaning of the sampling system. Evaluations were performed in 2000 – 2002 on two PNNL facilities to determine the operational and design impacts of the new requirements. The evaluation included inspection and cleaning maintenance activities plus testing to determine if the current sampling locations meet criteria in the revised standard. Results show a wide range of complexity in inspection and cleaning activities depending on accessibility of the system, ease of removal, and potential impact on building operations (need for outages). As expected, these High Efficiency Particulate Air (HEPA)-filtered systems did not show deposition significant enough to cause concerns with blocking of the nozzle or other parts of the system. The tests for sampling system location in the revised standard also varied in complexity depending on accessibility of the sample site and use of a scale model can alleviate many issues. Previous criteria to locate sampling systems at eight duct diameters downstream and two duct diameters upstream of the nearest disturbances is no guarantee of meeting criteria in the revised standard. A computational fluid dynamics model was helpful in understanding flow and

  7. Combination syringe provides air-free blood samples

    NASA Technical Reports Server (NTRS)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  8. Method and apparatus for sampling atmospheric mercury

    DOEpatents

    Trujillo, Patricio E.; Campbell, Evan E.; Eutsler, Bernard C.

    1976-01-20

    A method of simultaneously sampling particulate mercury, organic mercurial vapors, and metallic mercury vapor in the working and occupational environment and determining the amount of mercury derived from each such source in the sampled air. A known volume of air is passed through a sampling tube containing a filter for particulate mercury collection, a first adsorber for the selective adsorption of organic mercurial vapors, and a second adsorber for the adsorption of metallic mercury vapor. Carbon black molecular sieves are particularly useful as the selective adsorber for organic mercurial vapors. The amount of mercury adsorbed or collected in each section of the sampling tube is readily quantitatively determined by flameless atomic absorption spectrophotometry.

  9. Presence of organophosphorus pesticide oxygen analogs in air samples

    PubMed Central

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2012-01-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (< 30 ng/m3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  10. Presence of organophosphorus pesticide oxygen analogs in air samples

    NASA Astrophysics Data System (ADS)

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2013-02-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (<30 ng m-3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  11. Sampling system and method

    DOEpatents

    Decker, David L; Lyles, Brad F; Purcell, Richard G; Hershey, Ronald Lee

    2014-05-20

    An apparatus and method for supporting a tubing bundle during installation or removal. The apparatus includes a clamp for securing the tubing bundle to an external wireline. The method includes deploying the tubing bundle and wireline together, The tubing bundle is periodically secured to the wireline using a clamp.

  12. Innovations in air sampling to detect plant pathogens

    PubMed Central

    West, JS; Kimber, RBE

    2015-01-01

    Many innovations in the development and use of air sampling devices have occurred in plant pathology since the first description of the Hirst spore trap. These include improvements in capture efficiency at relatively high air-volume collection rates, methods to enhance the ease of sample processing with downstream diagnostic methods and even full automation of sampling, diagnosis and wireless reporting of results. Other innovations have been to mount air samplers on mobile platforms such as UAVs and ground vehicles to allow sampling at different altitudes and locations in a short space of time to identify potential sources and population structure. Geographical Information Systems and the application to a network of samplers can allow a greater prediction of airborne inoculum and dispersal dynamics. This field of technology is now developing quickly as novel diagnostic methods allow increasingly rapid and accurate quantifications of airborne species and genetic traits. Sampling and interpretation of results, particularly action-thresholds, is improved by understanding components of air dispersal and dilution processes and can add greater precision in the application of crop protection products as part of integrated pest and disease management decisions. The applications of air samplers are likely to increase, with much greater adoption by growers or industry support workers to aid in crop protection decisions. The same devices are likely to improve information available for detection of allergens causing hay fever and asthma or provide valuable metadata for regional plant disease dynamics. PMID:25745191

  13. Air Sampling Instruments for Evaluation of Atmospheric Contaminants. Fourth Edition.

    ERIC Educational Resources Information Center

    American Conference of Governmental Industrial Hygienists, Cincinnati, OH.

    This text, a revision and extension of the first three editions, consists of papers discussing the basic considerations in sampling air for specific purposes, sampler calibration, systems components, sample collectors, and descriptions of air-sampling instruments. (BT)

  14. A simple novel device for air sampling by electrokinetic capture

    DOE PAGESBeta

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of

  15. A simple novel device for air sampling by electrokinetic capture

    SciTech Connect

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the

  16. Assessment of estrogenic activity in PM₁₀ air samples with the ERE-CALUX bioassay: Method optimization and implementation at an urban location in Flanders (Belgium).

    PubMed

    Croes, Kim; Debaillie, Pieterjan; Van den Bril, Bo; Staelens, Jeroen; Vandermarken, Tara; Van Langenhove, Kersten; Denison, Michael S; Leermakers, Martine; Elskens, Marc

    2016-02-01

    Endocrine disrupting chemicals represent a broad class of compounds, are widespread in the environment and can pose severe health effects. The objective of this study was to investigate the overall estrogen activating potential of PM10 air samples at an urban location with high traffic incidence in Flanders, using a human in vitro cell bioassay. PM10 samples (n = 36) were collected on glass fiber filters every six days between April 2013 and January 2014 using a high-volume sampler. Extraction was executed with a hexane/acetone mixture before analysis using a recombinant estrogen-responsive human ovarian carcinoma (BG1Luc4E2) cell line. In addition, several samples and procedural blanks were extracted with ultra-pure ethanol or acetonitrile to compare extraction efficiencies. Results were expressed as bioanalytical equivalents (BEQs) in femtogram 17β-estradiol equivalent (fg E2-Eq) per cubic meter of air. High fluctuations in estrogenic activity were observed during the entire sampling period, with mean and median BEQs of 50.7 and 35.9 fg E2-Eq m(-)(3), respectively. Estrogenic activity was measured in more than 70% of the samples and several sample extracts showed both high BEQs and high cytotoxicity, which could not be related to black carbon, PM10 or heavy metal concentrations. At this moment, it remains unclear which substances cause this toxicity, but comparison of results obtained with different extraction solvents indicated that acetone/hexane extracts contained more compounds that were cytotoxic and suppressive of responses than those extracted using ultra-pure ethanol. Although more research is needed, the use of a more polar extraction solvent seems to be advisable. PMID:26383266

  17. Air Monitoring: New Advances in Sampling and Detection

    PubMed Central

    Watson, Nicola; Davies, Stephen; Wevill, David

    2011-01-01

    As the harmful effects of low-level exposure to hazardous organic air pollutants become more evident, there is constant pressure to improve the detection limits of indoor and ambient air monitoring methods, for example, by collecting larger air volumes and by optimising the sensitivity of the analytical detector. However, at the other end of the scale, rapid industrialisation in the developing world and growing pressure to reclaim derelict industrial land for house building is driving the need for air monitoring methods that can reliably accommodate very-high-concentration samples in potentially aggressive matrices. This paper investigates the potential of a combination of two powerful gas chromatography—based analytical enhancements—sample preconcentration/thermal desorption and time-of-flight mass spectrometry—to improve quantitative and qualitative measurement of very-low-(ppt) level organic chemicals, even in the most complex air samples. It also describes new, practical monitoring options for addressing equally challenging high-concentration industrial samples. PMID:22241966

  18. Diagnosing AIRS Sampling with CloudSat Cloud Classes

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric; Yue, Qing; Guillaume, Alexandre; Kahn, Brian

    2011-01-01

    AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.

  19. SAMPLING FOR ORGANIC CHEMICALS IN AIR

    EPA Science Inventory

    Organic chemicals by far account for the majority of pollutants found in air. ore than 90% of the 75,000 chemicals listed in EPA's Toxic Substances Control Act Chemical Substance Inventory and 88% of the 189 Hazardous Air Pollutants (HAPS) named in the Clean Air Act Amendments of...

  20. SOIL AND SEDIMENT SAMPLING METHODS

    EPA Science Inventory

    The EPA Office of Solid Waste and Emergency Response's (OSWER) Office of Superfund Remediation and Technology Innovation (OSRTI) needs innovative methods and techniques to solve new and difficult sampling and analytical problems found at the numerous Superfund sites throughout th...

  1. Evaluation of membrane filter field monitors for microbiological air sampling

    NASA Technical Reports Server (NTRS)

    Fields, N. D.; Oxborrow, G. S.; Puleo, J. R.; Herring, C. M.

    1974-01-01

    Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.

  2. Sampling of nitrates in ambient air

    NASA Astrophysics Data System (ADS)

    Appel, B. R.; Tokiwa, Y.; Haik, M.

    Methods for the measurement of nitric acid, particulate nitrate and total inorganic nitrate (i.e. HNO 3 plus particulate nitrate) are compared using atmospheric samples from the Los Angeles Basin. Nitric acid was measured by (1) the nitrate collected on nylon or NaCl-impregnated cellulose filters after removal of particulate matter with Teflon prefilters, (2) long-path Fourier transform infrared spectroscopy (FTIR) performed by a collaborating investigator, and (3) the difference between total inorganic nitrate (TIN) and particulate nitrate (PN). TIN was measured by the sum of the nitrate collected with a Teflon prefilter and nylon or NaCl-impregnated after-filter. PN was measured by the nitrate able to penetrate a diffusion dénuder coated to remove acidic gases (e.g. HNO 3). Losses of nitrate from Teflon prefilters were determined by comparing the nitrate retained by these filters to the nitrate penetrating the acid gas denuder. TIN and the nitrate collected with glass fiber filters were compared to assess the origin of the artifact particulate nitrate on the latter. Nitric acid measurements using nylon or NaCl-impregnated after-filters were substantially higher than those by the difference technique. This correlated with losses of nitrate from the Teflon prefilters, which exceeded 50 % at high ambient temperature and low relative humidity. Nitric acid by the difference method exceeded that by FTIR by, on average, 20 %. Thus errors inferred in HNO 3 measurements by comparison to the difference measurements are considered minimum values. The high values for HNO 3 by the difference method are consistent with the partial loss of PN in the acid gas denuder. However, no loss of 0.1 μm to 3 μm diameter NH 4NO 3 particles was observed. Thus, if significant, such loss is restricted to coarse particulate nitrate. Heating the filter samplers was shown to increase sampling errors. Nitrate results obtained in short-term, low volume sampling with Gelman A glass fiber

  3. Evaluation of official air sampling methodologies in Ukraine

    SciTech Connect

    Nakonechniy, J.J.; Wadden, R.A.; Scheff, P.A.; Suero, M.

    1997-12-31

    In conjunction with an environmental epidemiology study of the health of Ukrainian children, a significant amount of air pollution measurement data was gathered from government agencies. The areas of interest were the industrial city of Dneprodzherzhinsk; and the Dniprovsky region of Kyiv. The data were for 1993 and, for some of the monitoring stations, 1994. The pollutants reported included dust (approximately equivalent to TSP, total suspended particulate matter), SO{sub 2}, CO, NO{sub 2}, NO, H{sub 2}S, phenol, HCl, NH{sub 3}, formaldehyde, BaP, and lead. The ultimate goal was to evaluate whether existing historical data are appropriate for developing measures of human exposure. In order to evaluate the data it was necessary to understand the sampling and analytical methodologies which were used. Small sample volumes coupled with dated analytical procedures resulted in very poor precision and detection limits for most of the measured pollutants. The measurement of particulate matter is a good example of the limits imposed by the sampling methodology. The short sample time (20 min), small sample volume (150 lpm), and limited analytical balances (0.5 mg resolution) result in a minimum lower limit of detection of 0.25 mg/m{sup 3}. For example at Kyiv Station 3 in 1993, only one of 545 measurements exceeded 0.2 mg/m{sup 3}. This minimum detectable quantity is over three times the former US annual TSP standard. In addition, even when operated on a 24-hour basis in the US, it has been shown that the sampling method only collected approximately 34% of that collected by a co-located hi-vol sampler. Consequently, official air pollution data for suspended dust are likely to severely under-represent actual ambient concentrations. Data for other pollutants are presented and sampling and analytical methods are similarly compared with Western methods in common use.

  4. Elaborating transition interface sampling methods

    SciTech Connect

    Erp, Titus S. van . E-mail: bolhuis@science.uva.nl

    2005-05-01

    We review two recently developed efficient methods for calculating rate constants of processes dominated by rare events in high-dimensional complex systems. The first is transition interface sampling (TIS), based on the measurement of effective fluxes through hypersurfaces in phase space. TIS improves efficiency with respect to standard transition path sampling (TPS) rate constant techniques, because it allows a variable path length and is less sensitive to recrossings. The second method is the partial path version of TIS. Developed for diffusive processes, it exploits the loss of long time correlation. We discuss the relation between the new techniques and the standard reactive flux methods in detail. Path sampling algorithms can suffer from ergodicity problems, and we introduce several new techniques to alleviate these problems, notably path swapping, stochastic configurational bias Monte Carlo shooting moves and order-parameter free path sampling. In addition, we give algorithms to calculate other interesting properties from path ensembles besides rate constants, such as activation energies and reaction mechanisms.

  5. Perfluorocarbon tracer method for air-infiltration measurements

    DOEpatents

    Dietz, R.N.

    1982-09-23

    A method of measuring air infiltration rates suitable for use in rooms of homes and buildings comprises the steps of emitting perfluorocarbons in the room to be measured, sampling the air containing the emitted perfluorocarbons over a period of time, and analyzing the samples at a laboratory or other facility.

  6. A continuous sampling air-ICP for metals emission monitoring

    SciTech Connect

    Baldwin, D.P.; Zamzow, D.S.; Eckels, D.E.; Miller, G.P.

    1999-09-19

    An air-inductively coupled plasma (air-ICP) system has been developed for continuous sampling and monitoring of metals as a continuous emission monitor (CEM). The plasma is contained in a metal enclosure to allow reduced-pressure operation. The enclosure and plasma are operated at a pressure slightly less than atmospheric using a Roots blower, so that sample gas is continuously drawn into the plasma. A Teflon sampling chamber, equipped with a sampling pump, is connected to the stack that is to be monitored to isokinetically sample gas from the exhaust line and introduce the sample into the air-ICP. Optical emission from metals in the sampled gas stream is detected and monitored using an acousto-optic tunable filter (AOTF)--echelle spectrometer system. A description of the continuous sampling air-ICP system is given, along with some preliminary laboratory data for continuous monitoring of metals.

  7. Continuous sampling air-ICP for metals emission monitoring

    NASA Astrophysics Data System (ADS)

    Baldwin, David P.; Zamzow, Daniel S.; Eckels, David E.; Miller, George P.

    1999-12-01

    An air-inductively coupled plasma (air-ICP) system has been developed for continuous sampling and monitoring of metals as a continuous emission monitor (CEM). The plasma is contained in a metal enclosure to allow reduced-pressure operation. The enclosure and plasma are operated at a pressure slightly less than atmospheric using a Roots blower, so that sample gas is continuously drawn into the plasma. A Teflon sampling chamber, equipped with a sampling pump, is connected to the stack that is to be monitored to isokinetically sample gas from the exhaust line and introduce the sample into the air-ICP. Optical emission from metals in the sampled gas stream is detected and monitored using an acousto-optic tunable filter (AOTF)-echelle spectrometer system. A description of the continuous sampling air-ICP system is given, along with some preliminary laboratory data for continuous monitoring of metals.

  8. A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

    PubMed

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. PMID:26014445

  9. Methods for sampling of airborne viruses.

    PubMed

    Verreault, Daniel; Moineau, Sylvain; Duchaine, Caroline

    2008-09-01

    To better understand the underlying mechanisms of aerovirology, accurate sampling of airborne viruses is fundamental. The sampling instruments commonly used in aerobiology have also been used to recover viruses suspended in the air. We reviewed over 100 papers to evaluate the methods currently used for viral aerosol sampling. Differentiating infections caused by direct contact from those caused by airborne dissemination can be a very demanding task given the wide variety of sources of viral aerosols. While epidemiological data can help to determine the source of the contamination, direct data obtained from air samples can provide very useful information for risk assessment purposes. Many types of samplers have been used over the years, including liquid impingers, solid impactors, filters, electrostatic precipitators, and many others. The efficiencies of these samplers depend on a variety of environmental and methodological factors that can affect the integrity of the virus structure. The aerodynamic size distribution of the aerosol also has a direct effect on sampler efficiency. Viral aerosols can be studied under controlled laboratory conditions, using biological or nonbiological tracers and surrogate viruses, which are also discussed in this review. Lastly, general recommendations are made regarding future studies on the sampling of airborne viruses. PMID:18772283

  10. Methods for Sampling of Airborne Viruses

    PubMed Central

    Verreault, Daniel; Moineau, Sylvain; Duchaine, Caroline

    2008-01-01

    Summary: To better understand the underlying mechanisms of aerovirology, accurate sampling of airborne viruses is fundamental. The sampling instruments commonly used in aerobiology have also been used to recover viruses suspended in the air. We reviewed over 100 papers to evaluate the methods currently used for viral aerosol sampling. Differentiating infections caused by direct contact from those caused by airborne dissemination can be a very demanding task given the wide variety of sources of viral aerosols. While epidemiological data can help to determine the source of the contamination, direct data obtained from air samples can provide very useful information for risk assessment purposes. Many types of samplers have been used over the years, including liquid impingers, solid impactors, filters, electrostatic precipitators, and many others. The efficiencies of these samplers depend on a variety of environmental and methodological factors that can affect the integrity of the virus structure. The aerodynamic size distribution of the aerosol also has a direct effect on sampler efficiency. Viral aerosols can be studied under controlled laboratory conditions, using biological or nonbiological tracers and surrogate viruses, which are also discussed in this review. Lastly, general recommendations are made regarding future studies on the sampling of airborne viruses. PMID:18772283

  11. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); O'Brien, Martin J. (Inventor); Weimer, Carl S. (Inventor); Nelson, Loren D. (Inventor)

    2008-01-01

    Systems and methods for sensing air outside a moving aircraft are presented. In one embodiment, a system includes a laser for generating laser energy. The system also includes one or more transceivers for projecting the laser energy as laser radiation to the air. Subsequently, each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines one or more air parameters based on the scattered laser radiation. Such air parameters may include air speed, air pressure, air temperature and aircraft orientation angle, such as yaw, angle of attack and sideslip.

  12. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); Tang, Shoou-yu (Inventor); O'Brien, Martin (Inventor)

    2010-01-01

    Systems and methods for sensing air outside a moving aircraft are presented. In one embodiment, a system includes a laser for generating laser energy. The system also includes one or more transceivers for projecting the laser energy as laser radiation to the air. Subsequently, each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines one or more air parameters based on the scattered laser radiation. Such air parameters may include air speed, air pressure, air temperature and aircraft orientation angle, such as yaw, angle of attack and sideslip.

  13. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); O'Brien, Martin J. (Inventor); Weimer, Carl S. (Inventor); Nelson, Loren D. (Inventor)

    2005-01-01

    Systems and methods for sensing air outside a moving aircraft are presented. In one embodiment, a system includes a laser for generating laser energy. The system also includes one or more transceivers for projecting the laser energy as laser radiation to the air. Subsequently, each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines one or more air parameters based on the scattered laser radiation. Such air parameters may include air speed, air pressure, air temperature and aircraft orientation angle, such as yaw, angle of attack and sideslip.

  14. CONVENIENT SAMPLING OF AIR BACTERIA IN OPERATING ROOMS.

    PubMed

    WARNER, P; GLASSCO, A; KROEKER, J

    1964-02-22

    A convenient arrangement for sampling air bacteria in operating rooms with a slit sampler (the Fort Detrick sampler) is described. Its purpose is to contribute as far as possible to the convenience of the surgical staff and thereby to the safety of the patient. It has the advantages of recording minute-to-minute changes in bacterial air count; it is unobtrusive and yet can be continually observed by a technician; it is not noisy and avoids the dangers of explosion and static electricity; it is inexpensive, and parts are easily replaced; and finally it provides a means of keeping permanent photographic records of bacterial counts. Results of a preliminary trial of this method appeared to be satisfactory. PMID:14118695

  15. Venturi Air-Jet Vacuum Ejector For Sampling Air

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Burney, L. Garland; Wade, Larry O.

    1990-01-01

    Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

  16. Evaluation of Urban Air Quality By Passive Sampling Technique

    NASA Astrophysics Data System (ADS)

    Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.

    Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many

  17. Soil separator and sampler and method of sampling

    DOEpatents

    O'Brien, Barry H [Idaho Falls, ID; Ritter, Paul D [Idaho Falls, ID

    2010-02-16

    A soil sampler includes a fluidized bed for receiving a soil sample. The fluidized bed may be in communication with a vacuum for drawing air through the fluidized bed and suspending particulate matter of the soil sample in the air. In a method of sampling, the air may be drawn across a filter, separating the particulate matter. Optionally, a baffle or a cyclone may be included within the fluidized bed for disentrainment, or dedusting, so only the finest particulate matter, including asbestos, will be trapped on the filter. The filter may be removable, and may be tested to determine the content of asbestos and other hazardous particulate matter in the soil sample.

  18. 13c Measurements On Air of Small Ice Samples

    NASA Astrophysics Data System (ADS)

    Eyer, M.; Leuenberger, M.

    We have developed a new method for 13C analysis for very small air amounts of less than 0.5 cc STP, corresponding to less than 10 gram of ice. It is based on the needle-crasher technique, which we routinely use for CO2 concentration measurements by infrared laser absorption. The extracted air is slowly expanded into a large volume through a water trap held at ­100°C. This sampled air is then carried by a high helium flux through a modified Precon system of Thermo-Finnigan to separate CO2 from the air and to inject the pure CO2 gas in a low helium stream via an open split device to a Delta Plus XL mass spectrometer. The overall precision based on replicates of standard air is significantly better than 0.1 for a single analysis and is further improved by a triplicate measurement of the same sample through a specially designed gas splitter. We have used this new method for investigations on polar ice cores. The 13C measurements are important for climate reconstructions, e.g. to reconstruct the evolution and its variability in the terrestrial and oceanic carbon sinks and to identify natural variations in the marine carbon cycle. During the industrialization atmospheric 13C decreased by about -2, mainly due to the anthropogenic release of biogenic CO2 by fossil fuel burning. Reconstructions of carbon and oxygen cycles of Joos at al. [1999] using a double deconvolution method show that between 1930 and 1950 the net terrestrial release is changing to a net terrestrial uptake of CO2. A highly resolved 13C dataset of this time window would replenish the documentation of this behaviour. Further, it would be interesting to compare such data with O2/N2 measurements, known as an other partitioning tool for carbon sources and sinks. At the EGS 2002 we will present a highly resolved 13C record from Antarctic ice covering this time period.

  19. New Focus: method for measuring vinyl chloride in air

    SciTech Connect

    Not Available

    1987-05-01

    This note discusses a recently released standard entitled Method for the Measurement of Vinyl Chloride in Air (CAN3-Z223.25-M86). It is one in a series of Canadian Standard Association standards on the measurement of pollutants in air. This unique document provides a standardized method of sampling and analysis that may be used for the measurement of vinyl chloride in air over a concentration range of 0.01 to 2600 mg/mT under standard atmospheric conditions. The methodology includes calibration requirements, sampling procedures (the collection of samples in a gas bag or a sorbent tube), quantitative gas chromatographic analysis, and series of calculations. It is the first published document that standardizes the method of measurement of vinyl chloride in air and specifies a concentration range that applies to industrial hygiene and ambient air applications.

  20. APPLICATION OF SEMIPERMEABLE MEMBRANE DEVICES TO INDOOR AIR SAMPLING

    EPA Science Inventory

    Semipermeable membrane devices (SPMDs) are a relatively new passive sampling technique for nonpolar organic compounds that have been extensively used for surface water sampling. A small body of literature indicates that SPMDs are also useful for air sampling. Because SPMDs ha...

  1. EML Surface Air Sampling Program, 1990--1993 data

    SciTech Connect

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

  2. Solid waste transuranic storage and assay facility indoor air sampling

    SciTech Connect

    Pingel, L.A., Westinghouse Hanford

    1996-08-20

    The purpose of the study is to collect and analyze samples of the indoor air at the Transuranic Storage and Assay Facility (TRUSAF), Westinghouse Hanford. A modified US EPA TO-14 methodology, using gas chromatography/mass spectrography, may be used for the collection and analysis of the samples. The information obtained will be used to estimate the total release of volatile organic compounds from TRUSAF to determine the need for air emmission permits.

  3. Application of a dry-gas meter for measuring air sample volumes in an ambient air monitoring network

    SciTech Connect

    Fritz, Brad G.

    2009-05-24

    Ambient air monitoring for non-research applications (e.g. compliance) occurs at locations throughout the world. Often, the air sampling systems employed for these purposes employee simple yet robust equipment capable of handling the rigors of demanding sampling schedules. At the Hanford Site (near Richland, Washington) concentrations of radionuclides in ambient air are monitored continuously at 44 locations. In 2004, mechanical dry-gas meters were incorporated into the Hanford Site ambient air sample collection system to allow the direct measurement of sample volumes. These meters replaced a portable airflow measurement system that required two manual flow measurements and a sample duration measurement to determine sample volume. A six-month evaluation of the dry-gas meters compared sample volumes calculated using the original flow rate method to the direct sample volume measurement (new method). The results of the evaluation indicate that use of the dry-gas meters result in accurate sample volume measurements and provide greater confidence in the measured sample volumes. In several years of in-network use, the meters have proven to be reliable and have resulted in an improved sampling system.

  4. Efficiency of dust sampling inlets in calm air.

    PubMed

    Breslin, J A; Stein, R L

    1975-08-01

    Measurement of airborne dust concentrations usually involves drawing a sample of the dust-laden air into the measuring instrument through an inlet. Even if the surrounding air is calm, theoretical calculations predict that large particles may not be sampled accurately due to the combined effects of gravity and inertia on the particles near the sampling inlet. Tests were conducted to determine the conditions of particle size, inlet radius, and flow rare necessary for accurate dust sampling. A coal-dust aerosol was sampled simultaneously through inlets of different diameters at the same volume flow-rate and collected on filters. The dust was removed from the filters and the particles were counted and sized with a Coulter counter. Results showed that published criteria for inlet conditions for correct sampling are overly restrictive and that respirable-size particles are sampled correctly in the normal range or operation of most dust sampling instruments. PMID:1227283

  5. Sampling of air streams and incorporation of samples in the Microtox{trademark} toxicity testing system

    SciTech Connect

    Kleinheinz, G.T.; St. John, W.P.

    1997-10-01

    A study was conducted to develop a rapid and reliable method for the collection and incorporation of biofiltration air samples containing volatile organic compounds (VOCs) into the Microtox toxicity testing system. To date, no method exists for this type of assay. A constant stream of VOCs was generated by air stripping compounds from a complex mixture of petroleum hydrocarbons (PHCs). Samples were collected on coconut charcoal ORBO tubes and the VOCs extracted with methylene chloride. The compounds extracted were then solvent exchanged into dimethyl sulfoxide (DMSO) under gaseous nitrogen. The resulting DMSO extract was directly incorporated into the Microtox toxicity testing system. In order to determine the efficiency of the solvent exchange, the VOCs in the DMSO extract were then extracted into hexane and subsequently analyzed using gas chromatography (GC) with a flame ionization detector (FID). It was determined that all but the most volatile VOCs could be effectively transferred from the ORBO tubes to DMSO for Microtox testing. Potential trace amounts of residual methylene chloride in the DMSO extracts showed no adverse effects in the Microtox system when compared to control samples.

  6. Concepts for Environmental Radioactive Air Sampling and Monitoring

    SciTech Connect

    Barnett, J. Matthew

    2011-11-04

    Environmental radioactive air sampling and monitoring is becoming increasingly important as regulatory agencies promulgate requirements for the measurement and quantification of radioactive contaminants. While researchers add to the growing body of knowledge in this area, events such as earthquakes and tsunamis demonstrate how nuclear systems can be compromised. The result is the need for adequate environmental monitoring to assure the public of their safety and to assist emergency workers in their response. Two forms of radioactive air monitoring include direct effluent measurements and environmental surveillance. This chapter presents basic concepts for direct effluent sampling and environmental surveillance of radioactive air emissions, including information on establishing the basis for sampling and/or monitoring, criteria for sampling media and sample analysis, reporting and compliance, and continual improvement.

  7. Low-cost monitoring of Campylobacter in poultry houses by air sampling and quantitative PCR.

    PubMed

    Søndergaard, M S R; Josefsen, M H; Löfström, C; Christensen, L S; Wieczorek, K; Osek, J; Hoorfar, J

    2014-02-01

    The present study describes the evaluation of a method for the quantification of Campylobacter by air sampling in poultry houses. Sampling was carried out in conventional chicken houses in Poland, in addition to a preliminary sampling in Denmark. Each measurement consisted of three air samples, two standard boot swab fecal samples, and one airborne particle count. Sampling was conducted over an 8-week period in three flocks, assessing the presence and levels of Campylobacter in boot swabs and air samples using quantitative real-time PCR. The detection limit for air sampling was approximately 100 Campylobacter cell equivalents (CCE)/m3. Airborne particle counts were used to analyze the size distribution of airborne particles (0.3 to 10 μm) in the chicken houses in relation to the level of airborne Campylobacter. No correlation was found. Using air sampling, Campylobacter was detected in the flocks right away, while boot swab samples were positive after 2 weeks. All samples collected were positive for Campylobacter from week 2 through the rest of the rearing period for both sampling techniques, although levels 1- to 2-log CCE higher were found with air sampling. At week 8, the levels were approximately 10(4) and 10(5) CCE per sample for boot swabs and air, respectively. In conclusion, using air samples combined with quantitative real-time PCR, Campylobacter contamination could be detected earlier than by boot swabs and was found to be a more convenient technique for monitoring and/or to obtain enumeration data useful for quantitative risk assessment of Campylobacter. PMID:24490929

  8. Duplex sampling apparatus and method

    DOEpatents

    Brown, Paul E.; Lloyd, Robert

    1992-01-01

    An improved apparatus is provided for sampling a gaseous mixture and for measuring mixture components. The apparatus includes two sampling containers connected in series serving as a duplex sampling apparatus. The apparatus is adapted to independently determine the amounts of condensable and noncondensable gases in admixture from a single sample. More specifically, a first container includes a first port capable of selectively connecting to and disconnecting from a sample source and a second port capable of selectively connecting to and disconnecting from a second container. A second container also includes a first port capable of selectively connecting to and disconnecting from the second port of the first container and a second port capable of either selectively connecting to and disconnecting from a differential pressure source. By cooling a mixture sample in the first container, the condensable vapors form a liquid, leaving noncondensable gases either as free gases or dissolved in the liquid. The condensed liquid is heated to drive out dissolved noncondensable gases, and all the noncondensable gases are transferred to the second container. Then the first and second containers are separated from one another in order to separately determine the amount of noncondensable gases and the amount of condensable gases in the sample.

  9. Sampling and Analyzing Air Pollution: An Apparatus Suitable for Use in Schools.

    ERIC Educational Resources Information Center

    Rockwell, Dean M.; Hansen, Tony

    1994-01-01

    Describes two variations of an air sampler and analyzer that are inexpensive to construct, easy to operate, and designed to be used in an educational program. Variations use vacuum cleaners and aquarium pumps, and white facial tissues serve as filters. Samples of air pollution obtained by this method may be used from early grade school to advanced…

  10. Operational air sampling report, July--December 1991

    SciTech Connect

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician's (RPT) or health physicists' calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas.

  11. Operational air sampling report, July--December 1991

    SciTech Connect

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician`s (RPT) or health physicists` calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas.

  12. Apparatus and method for handheld sampling

    DOEpatents

    Staab, Torsten A.

    2005-09-20

    The present invention includes an apparatus, and corresponding method, for taking a sample. The apparatus is built around a frame designed to be held in at least one hand. A sample media is used to secure the sample. A sample media adapter for securing the sample media is operated by a trigger mechanism connectively attached within the frame to the sample media adapter.

  13. Field evaluation of a VOST sampling method

    SciTech Connect

    Jackson, M.D.; Johnson, L.D.; Fuerst, R.G.; McGaughey, J.F.; Bursey, J.T.; Merrill, R.G.

    1994-12-31

    The VOST (SW-846 Method 0030) specifies the use of Tenax{reg_sign} and a particular petroleum-based charcoal (SKC Lot 104, or its equivalent), that is no longer commercially available. In field evaluation studies of VOST methodology, a replacement petroleum-based charcoal has been used: candidate replacement sorbents for charcoal were studied, and Anasorb{reg_sign} 747, a carbon-based sorbent, was selected for field testing. The sampling train was modified to use only Anasorb{reg_sign} in the back tube and Tenax{reg_sign} in the two front tubes to avoid analytical difficulties associated with the analysis of the sequential bed back tube used in the standard VOST train. The standard (SW-846 Method 0030) and the modified VOST methods were evaluated at a chemical manufacturing facility using a quadruple probe system with quadruple trains. In this field test, known concentrations of the halogenated volatile organic compounds, that are listed in the Clean Air Act Amendments of 1990, Title 3, were introduced into the VOST train and the modified VOST train, using the same certified gas cylinder as a source of test compounds. Statistical tests of the comparability of methods were performed on a compound-by-compound basis. For most compounds, the VOST and modified VOST methods were found to be statistically equivalent.

  14. EVALUATION OF HIGH VOLUME PARTICLE SAMPLING AND SAMPLE HANDLING PROTOCOLS FOR AMBIENT URBAN AIR MUTAGENICITY DETERMINATIONS

    EPA Science Inventory

    An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S Environmental Protection Agency. hese protocols are used in urban ambient air studies which collect ambient and source samples...

  15. Soil sampling kit and a method of sampling therewith

    DOEpatents

    Thompson, C.V.

    1991-02-05

    A soil sampling device and a sample containment device for containing a soil sample is disclosed. In addition, a method for taking a soil sample using the soil sampling device and soil sample containment device to minimize the loss of any volatile organic compounds contained in the soil sample prior to analysis is disclosed. The soil sampling device comprises two close fitting, longitudinal tubular members of suitable length, the inner tube having the outward end closed. With the inner closed tube withdrawn a selected distance, the outer tube can be inserted into the ground or other similar soft material to withdraw a sample of material for examination. The inner closed end tube controls the volume of the sample taken and also serves to eject the sample. The soil sample containment device has a sealing member which is adapted to attach to an analytical apparatus which analyzes the volatile organic compounds contained in the sample. The soil sampling device in combination with the soil sample containment device allows an operator to obtain a soil sample containing volatile organic compounds and minimizing the loss of the volatile organic compounds prior to analysis of the soil sample for the volatile organic compounds. 11 figures.

  16. Soil sampling kit and a method of sampling therewith

    DOEpatents

    Thompson, Cyril V.

    1991-01-01

    A soil sampling device and a sample containment device for containing a soil sample is disclosed. In addition, a method for taking a soil sample using the soil sampling device and soil sample containment device to minimize the loss of any volatile organic compounds contained in the soil sample prior to analysis is disclosed. The soil sampling device comprises two close fitting, longitudinal tubular members of suitable length, the inner tube having the outward end closed. With the inner closed tube withdrawn a selected distance, the outer tube can be inserted into the ground or other similar soft material to withdraw a sample of material for examination. The inner closed end tube controls the volume of the sample taken and also serves to eject the sample. The soil sample containment device has a sealing member which is adapted to attach to an analytical apparatus which analyzes the volatile organic compounds contained in the sample. The soil sampling device in combination with the soil sample containment device allow an operator to obtain a soil sample containing volatile organic compounds and minimizing the loss of the volatile organic compounds prior to analysis of the soil sample for the volatile organic compounds.

  17. DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS

    SciTech Connect

    Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

    2012-09-20

    Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected

  18. Microorganisms cultured from stratospheric air samples obtained at 41 km.

    PubMed

    Wainwright, M; Wickramasinghe, N C; Narlikar, J V; Rajaratnam, P

    2003-01-21

    Samples of air removed from the stratosphere, at an altitude of 41 km, were previously found to contain viable, but non-cultureable bacteria (cocci and rods). Here, we describe experiments aimed at growing these, together with any other organisms, present in these samples. Two bacteria (Bacillus simplex and Staphylococcus pasteuri) and a single fungus, Engyodontium album (Limber) de Hoog were isolated from the samples. Although the possibility of contamination can never be ruled out when space-derived samples are studied on earth, we are confident that the organisms originated from the stratosphere. Possible mechanisms by which these organisms could have attained such a height are discussed. PMID:12583913

  19. Sampling frequency guidance for ambient air toxics monitoring.

    PubMed

    Bortnick, Steven M; Stetzer, Shannon L

    2002-07-01

    The U.S. Environmental Protection Agency (EPA) is in the process of designing a national network to monitor hazardous air pollutants (HAPs), also known as air toxics. The purposes of the expanded monitoring are to (1) characterize ambient concentrations in representative areas; (2) provide data to support and evaluate dispersion and receptor models; and (3) establish trends and evaluate the effectiveness of HAP emission reduction strategies. Existing air toxics data, in the form of an archive compiled by EPA's Office of Air Quality Planning and Standards (OAQPS), are used in this paper to examine the relationship between estimated annual average (AA) HAP concentrations and their associated variability. The goal is to assess the accuracy, or bias and precision, with which the AA can be estimated as a function of ambient concentration levels and sampling frequency. The results suggest that, for several air toxics, a sampling schedule of 1 in 3 days (1:3) or 1:6 days maybe appropriate for meeting some of the general objectives of the national network, with the more intense sampling rate being recommended for areas expected to exhibit relatively high ambient levels. PMID:12139351

  20. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); Tang, Shoou-yu (Inventor); Acott, Phillip E. (Inventor); Spaeth, Lisa G. (Inventor); O'Brien, Martin (Inventor)

    2011-01-01

    Systems and methods for sensing air includes at least one, and in some embodiments three, transceivers for projecting the laser energy as laser radiation to the air. The transceivers are scanned or aligned along several different axes. Each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines air temperatures, wind speeds, and wind directions based on the scattered laser radiation. Applications of the system to wind power site evaluation, wind turbine control, traffic safety, general meteorological monitoring and airport safety are presented.

  1. Compendium of methods for the determination of air pollutants in indoor air

    SciTech Connect

    Winberry, W.T.; Forehand, L.; Murphy, N.T.; Ceroli, A.; Phinney, B.

    1990-04-01

    Determination of pollutants in indoor air is a complex task because of the wide variety of compounds of interest and the lack of standardized sampling and analysis procedures. To assist agencies and persons responsible for sampling and analysis of indoor pollutants, the methods compendium provides current, technically-reviewed sampling and analysis procedures in a standardized format for determination of selected pollutants of primary importance in indoor air. Each chapter contains one or more active or passive sampling procedures along with one or more appropriate analytical procedures. The ten chapters of the compendium cover determination of volatile organic compounds, nicotine, carbon monoxide and carbon dioxide, air exchange rate, nitrogen dioxide, formaldehyde, benzo(a)pyrene and other polynuclear aromatic hydrocarbons, acid gases and aerosols, particulate matter, and pesticides. As further advancements are made, the procedures may be modified or updated, or additional methods may be added as appropriate.

  2. Bioassay vs. Air Sampling: Practical Guidance and Experience at Hanford

    SciTech Connect

    Carbaugh, Eugene H.; Carlson, Eric W.; Hill, Robin L.

    2004-02-08

    The Hanford Site has implemented a policy to guide in determining whether air sampling data or special fecal bioassay data are more appropriate for determining doses of record for low-level plutonium exposures. The basis for the policy and four years of experience in comparing DAC-hours exposure with bioassay-based dosimetry is discussed.

  3. TETHERED BALLOON SAMPLING SYSTEMS FOR MONITORING AIR POLLUTION

    EPA Science Inventory

    The paper is an overview of recent studies in which balloons, usually tethered, have been used to investigate the structure and air quality of the planetary boundary layer. It also describes a number of lightweight tethered balloon sampling systems, developed to investigate parti...

  4. An improved sampling method of complex network

    NASA Astrophysics Data System (ADS)

    Gao, Qi; Ding, Xintong; Pan, Feng; Li, Weixing

    2014-12-01

    Sampling subnet is an important topic of complex network research. Sampling methods influence the structure and characteristics of subnet. Random multiple snowball with Cohen (RMSC) process sampling which combines the advantages of random sampling and snowball sampling is proposed in this paper. It has the ability to explore global information and discover the local structure at the same time. The experiments indicate that this novel sampling method could keep the similarity between sampling subnet and original network on degree distribution, connectivity rate and average shortest path. This method is applicable to the situation where the prior knowledge about degree distribution of original network is not sufficient.

  5. Toward cost-efficient sampling methods

    NASA Astrophysics Data System (ADS)

    Luo, Peng; Li, Yongli; Wu, Chong; Zhang, Guijie

    2015-09-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper proposes two new sampling methods based on the idea that a small part of vertices with high node degree could possess the most structure information of a complex network. The two proposed sampling methods are efficient in sampling high degree nodes so that they would be useful even if the sampling rate is low, which means cost-efficient. The first new sampling method is developed on the basis of the widely used stratified random sampling (SRS) method and the second one improves the famous snowball sampling (SBS) method. In order to demonstrate the validity and accuracy of two new sampling methods, we compare them with the existing sampling methods in three commonly used simulation networks that are scale-free network, random network, small-world network, and also in two real networks. The experimental results illustrate that the two proposed sampling methods perform much better than the existing sampling methods in terms of achieving the true network structure characteristics reflected by clustering coefficient, Bonacich centrality and average path length, especially when the sampling rate is low.

  6. Marine Technician's Handbook, Instructions for Taking Air Samples on Board Ship: Carbon Dioxide Project.

    ERIC Educational Resources Information Center

    Keeling, Charles D.

    This booklet is one of a series intended to provide explicit instructions for the collection of oceanographic data and samples at sea. The methods and procedures described have been used by the Scripps Institution of Oceanography and found reliable and up-to-date. Instructions are given for taking air samples on board ship to determine the…

  7. Airing method-specific advertisements.

    PubMed

    Yaser, Y

    1992-06-01

    The Turkish Family Health and Planning Foundation initiated the commercial marketing of contraceptives in 1989 as part of a Contraceptive Social Marketing (CSM) program to make available low-cost contraceptives. In 1988 modern methods were used by 31% and traditional methods by 32.3%, while 36.6% used no contraceptives. Only 6.2% were current pill users mainly because of health reasons since high-dose pills dominated the market. A 1990 survey among urban consumers indicated a 94% awareness of contraceptive methods, 76.1% of current use, and preference for the IUD. The side effects of the pill were cited for disliking it, and the condom was rated higher. The CSM project aims at popularizing low-dose pills by explaining the differences and benefits regarding high-dose pills. It collaborated with manufacturers: Schering, Wyeth, Organon, and Eczacibasi Ilac. In 1991 a TV and radio advertisement campaign started that involves the low-dose products Microgynon, Triquilar, Desolet, Lo-Ovral, and Tri-Nordial. The introduction of the Okey condom by Eczacibasi Ilac. In June 1991 also entailed extensive promotion with newspaper ads and TV spots after getting official permission. 1.3 million condoms were sold in the 1st 2 months in 13,000 retail outlets, and 4 million more were projected to be sold. A shift of the attitude of supermarket owners allowing stocking of condoms and the support of the Turkish Ministry of Health, USAID, and the Turkish Radio and Television Bureau has facilitated the CSM project implementation that will profoundly affect family planning in Turkey. PMID:12285550

  8. An analytical method coupling accelerated solvent extraction and HPLC-fluorescence for the quantification of particle-bound PAHs in indoor air sampled with a 3-stages cascade impactor.

    PubMed

    Liaud, Céline; Millet, Maurice; Le Calvé, Stéphane

    2015-01-01

    Most of Polycyclic Aromatic Hydrocarbons (PAHs) are associated to airborne particles and their health impact depends on the particle size where they are bound. This work aims to develop a high sensitive analytical technique to quantify particulate PAHs sampled with a 3-stages cascade impactor in order to derive simultaneously their individual concentration in PM1, PM2.5 and PM10. Three key steps of the method were evaluated separately in order to avoid any PAHs loss during the global sample preparation procedure: (1) the accelerated solvent extraction of PAHs from the filter; (2) the primary concentration of the extract until 1 mL by means of a rotary evaporator at 45°C and 220 mbar and (3) the final concentration of the pre-concentrated extract to about 100-150 µL under a gentle nitrogen stream. Each recovery experiment was realized in triplicates. All these steps evaluated independently show that the overall PAHs loss, even for those with a low molecular weight, should not exceed more than a few percent. Extracts were then analyzed by using a HPLC coupled to fluorescence and Diode Array Detectors with the external standard method. The resulting calibration curves containing between 9 and 12 points were plotted in the concentration range of 0.05-45 µg L(-1) for most of the 16 US-EPA priority PAHs and were fully linear (R(2)>0.999). Limits Of Quantification were in the range 0.05-0.47 µg L(-1) corresponding to 0.75-7.05 pg m(-3) for 20 m(3) of pumped air. Finally, taking into account the average PAHs concentrations previously reported in typical European indoor environments, and considering the use of a 3-stages cascade impactor to collect simultaneously PM>10 µm, 2.5 µmsampling duration was estimated to 20-40 h for a sampling flow fixed to 0.5m(3)h(-1). PMID:25281119

  9. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); Tang, Shoou-Yu (Inventor); O'Brien, Martin J. (Inventor)

    2009-01-01

    A method for remotely sensing air outside a moving aircraft includes generating laser radiation within a swept frequency range. A portion of the laser radiation is projected from the aircraft into the air to induce scattered laser radiation. Filtered scattered laser radiation, filtered laser radiation, and unfiltered laser radiation are detected. At least one actual ratio is determined from data corresponding to the filtered scattered laser radiation and the unfiltered laser radiation. One or more air parameters are determined by correlating the actual ratio to at least one reference ratio.

  10. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); Tang, Shoou-Yu (Inventor); O'Brien, Martin J. (Inventor)

    2011-01-01

    A method for remotely sensing air outside a moving aircraft includes generating laser radiation within a swept frequency range. A portion of the laser radiation is projected from the aircraft into the air to induce scattered laser radiation. Filtered scattered laser radiation, filtered laser radiation, and unfiltered laser radiation are detected. At least one actual ratio is determined from data corresponding to the filtered scattered laser radiation and the unfiltered laser radiation. One or more air parameters are determined by correlating the actual ratio to at least one reference ratio.

  11. Can car air filters be useful as a sampling medium for air pollution monitoring purposes?

    PubMed

    Katsoyiannis, Athanasios; Birgul, Askin; Ratola, Nuno; Cincinelli, Alessandra; Sweetman, Andy J; Jones, Kevin C

    2012-11-01

    Urban air quality and real human exposure to chemical environmental stressors is an issue of high scientific and political interest. In an effort to find innovative and inexpensive means for air quality monitoring, the ability of car engine air filters (CAFs) to act as efficient samplers collecting street level air, to which people are exposed to, was tested. In particular, in the case of taxis, air filters are replaced after regular distances, the itineraries are almost exclusively urban, cruising mode is similar and, thus, knowledge of the air flow can provide with an integrated city air sample. The present pilot study focused on polycyclic aromatic hydrocarbons (PAHs), the most important category of organic pollutants associated with traffic emissions. Concentrations of ΣPAHs in CAFs ranged between 650 and 2900 μg CAF(-1), with benzo[b]fluoranthene, benzo[k]fluoranthene and indeno[123-cd]pyrene being the most abundant PAHs. Benzo[a]pyrene (BaP) ranged between 110 and 250 μg CAF(-1), accounting regularly for 5-15% of the total carcinogenic PAHs. The CAF PAH loads were used to derive road-level atmospheric PAH concentrations from a standard formula relating to the CAF air flow. Important parameters/assumptions for these estimates are the cruising speed and the exposure duration of each CAF. Based on information obtained from the garage experts, an average 'sampled air volume' of 48,750 m(3) per CAF was estimated, with uncertainty in this calculation estimated to be about a factor of 4 between the two extreme scenarios. Based on this air volume, ΣPAHs ranged between 13 and 56 ng m(-3) and BaP between 2.1 and 5.0 ng m(-3), suggesting that in-traffic BaP concentrations can be many times higher than the limit values set by the UK (0.25 ng m(-3)) and the European Union (1.0 ng m(-3)), or from active sampling stations normally cited on building roof tops or far from city centres. Notwithstanding the limitations of this approach, the very low cost, the continuous

  12. ASTM Validates Air Pollution Test Methods

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  13. Subrandom methods for multidimensional nonuniform sampling.

    PubMed

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics. PMID:27301071

  14. Subrandom methods for multidimensional nonuniform sampling

    NASA Astrophysics Data System (ADS)

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics.

  15. Artifact peroxides produced during cryogenic sampling of ambient air

    NASA Astrophysics Data System (ADS)

    Staffelbach, Thomas; Neftel, Albrecht; Dasgupta, Purnendu K.

    Peroxides were found to be produced as artifacts during cryogenic sampling with Horibe traps. Cryogenic trap sampling was compared to collection with a wet effluent diffusion denuder and a Nafion membrane diffusion denuder. Hydrogen peroxide and hydroxymethyl hydroperoxide measured in the cryogenic trap samples were significantly higher. In comparison, no evidence of artifact methyl hydroperoxide production was found. The amount of artifact H2O2 and HMHP produced increased with decreasing trap temperature. Spiking ambient air with ethene or isoprene showed that these hydrocarbons, in the presence of ozone, can be responsible for the artifact production of peroxides. Our results clearly suggest that the peroxide data obtained by cryogenic sampling and reported in the literature should be interpreted with caution.

  16. Method and apparatus for data sampling

    DOEpatents

    Odell, D.M.C.

    1994-04-19

    A method and apparatus for sampling radiation detector outputs and determining event data from the collected samples is described. The method uses high speed sampling of the detector output, the conversion of the samples to digital values, and the discrimination of the digital values so that digital values representing detected events are determined. The high speed sampling and digital conversion is performed by an A/D sampler that samples the detector output at a rate high enough to produce numerous digital samples for each detected event. The digital discrimination identifies those digital samples that are not representative of detected events. The sampling and discrimination also provides for temporary or permanent storage, either serially or in parallel, to a digital storage medium. 6 figures.

  17. Method and apparatus for data sampling

    DOEpatents

    Odell, Daniel M. C.

    1994-01-01

    A method and apparatus for sampling radiation detector outputs and determining event data from the collected samples. The method uses high speed sampling of the detector output, the conversion of the samples to digital values, and the discrimination of the digital values so that digital values representing detected events are determined. The high speed sampling and digital conversion is performed by an A/D sampler that samples the detector output at a rate high enough to produce numerous digital samples for each detected event. The digital discrimination identifies those digital samples that are not representative of detected events. The sampling and discrimination also provides for temporary or permanent storage, either serially or in parallel, to a digital storage medium.

  18. Formal Methods Applications in Air Transportation

    NASA Technical Reports Server (NTRS)

    Farley, Todd

    2009-01-01

    The U.S. air transportation system is the most productive in the world, moving far more people and goods than any other. It is also the safest system in the world, thanks in part to its venerable air traffic control system. But as demand for air travel continues to grow, the air traffic control system s aging infrastructure and labor-intensive procedures are impinging on its ability to keep pace with demand. And that impinges on the growth of our economy. Air traffic control modernization has long held the promise of a more efficient air transportation system. Part of NASA s current mission is to develop advanced automation and operational concepts that will expand the capacity of our national airspace system while still maintaining its excellent record for safety. It is a challenging mission, as efforts to modernize have, for decades, been hamstrung by the inability to assure safety to the satisfaction of system operators, system regulators, and/or the traveling public. In this talk, we ll provide a brief history of air traffic control, focusing on the tension between efficiency and safety assurance, and the promise of formal methods going forward.

  19. Mixed Methods Sampling: A Typology with Examples

    ERIC Educational Resources Information Center

    Teddlie, Charles; Yu, Fen

    2007-01-01

    This article presents a discussion of mixed methods (MM) sampling techniques. MM sampling involves combining well-established qualitative and quantitative techniques in creative ways to answer research questions posed by MM research designs. Several issues germane to MM sampling are presented including the differences between probability and…

  20. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  1. ALARA ASSESSMENT OF SETTLER SLUDGE SAMPLING METHODS

    SciTech Connect

    NELSEN LA

    2009-01-30

    The purpose of this assessment is to compare underwater and above water settler sludge sampling methods to determine if the added cost for underwater sampling for the sole purpose of worker dose reductions is justified. Initial planning for sludge sampling included container, settler and knock-out-pot (KOP) sampling. Due to the significantly higher dose consequence of KOP sludge, a decision was made to sample KOP underwater to achieve worker dose reductions. Additionally, initial plans were to utilize the underwater sampling apparatus for settler sludge. Since there are no longer plans to sample KOP sludge, the decision for underwater sampling for settler sludge needs to be revisited. The present sampling plan calls for spending an estimated $2,500,000 to design and construct a new underwater sampling system (per A21 C-PL-001 RevOE). This evaluation will compare and contrast the present method of above water sampling to the underwater method that is planned by the Sludge Treatment Project (STP) and determine if settler samples can be taken using the existing sampling cart (with potentially minor modifications) while maintaining doses to workers As Low As Reasonably Achievable (ALARA) and eliminate the need for costly redesigns, testing and personnel retraining.

  2. Laboratory validation and field verification of a new passive colorimetric air monitoring badge for sampling hydrogen sulfide in air.

    PubMed

    Kring, E V; Damrell, D J; Henry, T J; DeMoor, H M; Basilio, A N; Simon, C E

    1984-01-01

    The Pro-Tek passive colorimetric air monitoring badge for personal or area sampling of hydrogen sulfide is described. The badge has been validated over the range of 1.8 to 164 ppm-hours (0.23-21 ppm on an 8-hour TWA basis). It has an overall accuracy throughout this range of +/- 15.9% and meets the NIOSH accuracy criteria for an analytical and sampling method. The colorimetric analytical method used is based on the Texas Air Control Board's Molybdenum Blue method. Color-activated exposed badge solutions are read out on a standard laboratory spectrophotometer using 1 centimeter (10 mm) cells. Variations in exposure temperature (between 10 degrees and 40 degrees C), relative humidity, and face velocity (between 2 and 250 ft/min) do not affect badge performance. Unexposed badges are stable for more than 12 months refrigerated and for two months at room temperature. PMID:6702591

  3. Ambient Air Sampling During Quantum-dot Spray Deposition

    SciTech Connect

    Jankovic, John Timothy; Hollenbeck, Scott M

    2010-01-01

    Ambient air sampling for nano-size particle emissions was performed during spot spray coating operations with a Sono-Tek Exactacoat Benchtop system (ECB). The ECB consisted of the application equipment contained within an exhaust enclosure. The enclosure contained numerous small access openings, including an exhaust hook-up. Door access comprised most of the width and height of the front. The door itself was of the swing-out type. Two types of nanomaterials, Cadmium selenide (Cd-Se) quantum-dots (QDs) and Gold (Au) QDs, nominally 3.3 and 5 nm in diameter respectively, were applied during the evaluation. Median spray drop size was in the 20 to 60 micrometer size range.1 Surface coating tests were of short duration, on the order of one-half second per spray and ten spray applications between door openings. The enclosure was ventilated by connection to a high efficiency particulate aerosol (HEPA) filtered house exhaust system. The exhaust rate was nominally 80 ft3 per minute producing about 5 air changes per minute. Real time air monitoring with a scanning mobility particle size analyzer (SMPS ) with a size detection limit of 7 nm indicated a significant increase in the ambient air concentration upon early door opening. A handheld condensation particle counter (CPC) with a lower size limit of 10 nm did not record changes in the ambient background. This increase in the ambient was not observed when door opening was delayed for 2 minutes (~10 air changes). The ventilated enclosure controlled emissions except for cases of rapid door opening before the overspray could be removed by the exhaust. A time delay sufficient to provide 10 enclosure air changes (a concentration reduction of more than 99.99 %) before door opening prevented the release of aerosol particles in any size.2 Scanning-transmission electron microscopy (STEM) and atomic force microscopy (AFM) demonstrated the presence of agglomerates in the surfaces of the spray applied deposition. A filtered air sample of

  4. Passive air sampling of gaseous elemental mercury: a critical review

    NASA Astrophysics Data System (ADS)

    McLagan, David S.; Mazur, Maxwell E. E.; Mitchell, Carl P. J.; Wania, Frank

    2016-03-01

    Because gaseous elemental mercury (GEM) is distributed globally through the atmosphere, reliable means of measuring its concentrations in air are important. Passive air samplers (PASs), designed to be cheap, simple to operate, and to work without electricity, could provide an alternative to established active sampling techniques in applications such as (1) long-term monitoring of atmospheric GEM levels in remote regions and in developing countries, (2) atmospheric mercury source identification and characterization through finely resolved spatial mapping, and (3) the recording of personal exposure to GEM. An effective GEM PAS requires a tightly constrained sampling rate, a large and stable uptake capacity, and a sensitive analytical technique. None of the GEM PASs developed to date achieve levels of accuracy and precision sufficient for the reliable determination of background concentrations over extended deployments. This is due to (1) sampling rates that vary due to meteorological factors and manufacturing inconsistencies, and/or (2) an often low, irreproducible and/or unstable uptake capacity of the employed sorbents. While we identify shortcomings of existing GEM PAS, we also reveal potential routes to overcome those difficulties. Activated carbon and nanostructured metal surfaces hold promise as effective sorbents. Sampler designs incorporating diffusive barriers should be able to notably reduce the influence of wind on sampling rates.

  5. Passive air sampling of gaseous elemental mercury: a critical review

    NASA Astrophysics Data System (ADS)

    McLagan, D. S.; Mazur, M. E. E.; Mitchell, C. P. J.; Wania, F.

    2015-12-01

    Because gaseous elemental mercury (GEM) is distributed globally through the atmosphere, reliable means of measuring its concentrations in air are important. Passive air samplers (PASs), designed to be cheap, simple to operate, and to work without electricity, could provide an alternative to established active sampling techniques in applications such as (1) long term monitoring of atmospheric GEM levels in remote regions and in developing countries, (2) atmospheric mercury source identification and characterisation through finely-resolved spatial mapping, and (3) the recording of personal exposure to GEM. An effective GEM PAS requires a tightly constrained sampling rate, a large and stable uptake capacity, and a sensitive analytical technique. None of the GEM PASs developed to date achieves levels of accuracy and precision sufficient for the reliable determination of background concentrations over extended deployments. This is due to (1) sampling rates that vary due to meteorological factors and manufacturing inconsistencies and/or (2) an often low, irreproducible and/or unstable uptake capacity of the employed sorbents. While we identify shortcomings of existing GEM PAS, we also reveal potential routes to overcome those difficulties. Activated carbon and nano-structured metal surfaces hold promise as effective sorbents. Sampler designs incorporating diffusive barriers should be able to notably reduce the influence of wind on sampling rates.

  6. Optimization of the development process for air sampling filter standards

    NASA Astrophysics Data System (ADS)

    Mena, RaJah Marie

    Air monitoring is an important analysis technique in health physics. However, creating standards which can be used to calibrate detectors used in the analysis of the filters deployed for air monitoring can be challenging. The activity of a standard should be well understood, this includes understanding how the location within the filter affects the final surface emission rate. The purpose of this research is to determine the parameters which most affect uncertainty in an air filter standard and optimize these parameters such that calibrations made with them most accurately reflect the true activity contained inside. A deposition pattern was chosen from literature to provide the best approximation of uniform deposition of material across the filter. Samples sets were created varying the type of radionuclide, amount of activity (high activity at 6.4 -- 306 Bq/filter and one low activity 0.05 -- 6.2 Bq/filter, and filter type. For samples analyzed for gamma or beta contaminants, the standards created with this procedure were deemed sufficient. Additional work is needed to reduce errors to ensure this is a viable procedure especially for alpha contaminants.

  7. A Cryosampler Payload for Aseptic Air Sample Collection at Stratospheric Altitudes Using Balloons.

    NASA Astrophysics Data System (ADS)

    Sreenivasan, S.; Dutt, C. B. S.; Bhargava, P.; Shivaji, S.; Manchanda, R. K.

    A balloon borne Astrobiology program is being conducted from the National Balloon Facility of the Tata Institute of Fundamental Research at Hyderabad India in which a liquid Neon cooled cryo pump collects air samples under sterile conditions in the altitude regime 19 - 41 Km Pursuant to the encouraging results obtained from an earlier experiment conducted on January 2001 a new payload was configured and the balloon flight was conducted on April 20 2005 after implementing much more rigorous and enhanced sterilization protocol to completely rule out contamination from ground Air samples were collected in the altitude region 20 - 41 Km and are under analysis in the National laboratories in India for detecting the presence of living microbial cells In this paper we discuss the design and fabrication of the air sample collection probes the stringent sterilization protocol evolved for ensuring that the probes are aseptic before the commencement of the experiment and the sample retrival methods for analysis in the laboratory

  8. SAMPLING AND DATA HANDLING METHODS FOR INHALABLE PARTICULATE SAMPLING

    EPA Science Inventory

    The report reviews the objectives of a research program on sampling and measuring particles in the inhalable particulate (IP) size range in emissions from stationary sources, and describes methods and equipment required. A computer technique was developed to analyze data on parti...

  9. Sampling and analysis of terpenes in air. An interlaboratory comparison

    NASA Astrophysics Data System (ADS)

    Larsen, Bo; Bomboi-Mingarro, Teresa; Brancaleoni, Enzo; Calogirou, Aggelos; Cecinato, Angelo; Coeur, Cecile; Chatzinestis, Ioannis; Duane, Matthew; Frattoni, Massimiliano; Fugit, Jean-Luc; Hansen, Ute; Jacob, Veronique; Mimikos, Nikolaos; Hoffmann, Thorsten; Owen, Susan; Perez-Pastor, Rosa; Reichmann, Andreas; Seufert, Gunther; Staudt, Michael; Steinbrecher, Rainer

    An interlaboratory comparison on the sampling and analysis of terpenes in air was held within the framework of the BEMA (Biogenic Emissions in the Mediterranean Area) project in May 1995. Samples were drawn and analysed by 10 European laboratories from a dynamic artificial air generator in which five terpenes were present at low ng ℓ -1 levels and ozone varied between 8 and 125 ppbv. Significant improvements over previous inter-comparison exercises in the quality of results were observed. At the ozone mixing ratio of 8 ppbv a good agreement among laboratories was obtained for all test compounds with mean values close to the target concentration. At higher mixing ratios, ozone reduced terpene recoveries and decreased the precision of the measurements due to ozonolysis during sampling. For β-pinene this effect was negligible but for the more reactive compounds significant losses were observed in some laboratories ( cis-β-ocimene = trans-β-ocimene > linalool > d-limonene). The detrimental effect of ozone was significantly lower for the laboratories which removed ozone prior to sampling by scrubbers. Parallel sampling was carried out with a standardised sampler and each individual laboratory's own device. A good agreement between the two sets of results was obtained, clearly showing that the majority of laboratories used efficient sampling systems. Two different standard solutions were analysed by each laboratory. Only in a few cases did interference in the GC separation cause problems for the quantification of the terpenes (nonanal/linalool). However, making up of standards for the calibration of the analytical equipment (GC-MS or GC-FID) was pointed out as a source of error in some laboratories.

  10. Relative Humidity and its Effect on Sampling and Analysis of Agricultural Odorants in Air

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Source and ambient air sampling techniques used in agricultural air quality studies are seldom validated for the variability in the air matrix (temperature, dust levels, and relative humidity). In particular, relative humidity (RH) affects both field sampling and analysis of air samples. The objec...

  11. Sample normalization methods in quantitative metabolomics.

    PubMed

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. PMID:26763302

  12. Field test of a generic method for the sampling and analysis of halogenated hydrocarbons listed in title III of the Clean Air Act amendments of 1990. Report for January 1992-December 1993

    SciTech Connect

    McGaughey, J.F.; Bursey, J.T.; Rice, J.; Merrill, R.G.; Jackson, M.D.

    1993-01-01

    To validate a new source test method for EPA use, the performance of the sampling and analytical methodology for the chemicals of interest must be established and demonstrated through field tests at sources similar to those of interest. Validation studies for measuring volatile and semi-volatile halogenated organics were undertaken in two different studies. Repeated sampling runs of the Volatile Organic Sample Train (VOST; SW-846 Sampling Method 0030 with Analytical Method 5041) and Semi-Volatile Organic Sample Train (Semi-VOST; SW-846 Method 0010 with Analytical Method 8270) were collected at two source locations. Quadruple sampling trains were used in each run, with two of the trains being spiked with standards. For the VOST method, the results of the two field studies were consistent with laboratory tests. For the Semi-VOST method, consistent results were obtained in the laboratory study and one of the field tests. At the second field site, the Semi-VOST data were inadequate because of problems encountered in preparation of the samples for analysis.

  13. Survey of volatile organic compounds found in indoor and outdoor air samples from Japan.

    PubMed

    Tanaka-Kagawa, Toshiko; Uchiyama, Shigehisa; Matsushima, Erika; Sasaki, Akira; Kobayashi, Hiroshi; Kobayashi, Hiromi; Yagi, Masahiro; Tsuno, Masahiko; Arao, Masa; Ikemoto, Kazumi; Yamasaki, Makoto; Nakashima, Ayako; Shimizu, Yuri; Otsubo, Yasufumi; Ando, Masanori; Jinno, Hideto; Tokunaga, Hiroshi

    2005-01-01

    Indoor air quality is currently a growing concern, mainly due to the incidence of sick building syndrome and building related illness. To better understand indoor air quality in Japan, both indoor and outdoor air samples were collected from 50 residences in Iwate, Yamanashi, Shiga, Hyogo, Kochi and Fukuoka Prefectures. More than 100 volatile organic compounds (VOCs) were analyzed by thermal desorption-gas chromatography/mass spectrometry method. The most abundant class of compounds present in the indoor air samples were identified (i.e. alkanes, alkylbenzenes and terpenes). For 30% of the indoor air samples, the sum of each VOC exceeded the current provisional guideline value for total VOC (TVOC, 400 microg/m3). The major component of these samples included linear and branched-chain alkanes (possibly derived from fossil fuels), 1,4-dichlorobenzene (a moth repellent), alpha-pinene (emission from woody building materials) and limonene (probably derived from aroma products). As an unexpected result, one residence was polluted with an extremely high concentration of 1,1,1,2-tetrafluoroethane (720 microg/m3), suggesting accidental leakage from a household appliance such as a refrigerator. The results presented in this paper are important in establishing the Japanese target compound list for TVOC analysis, as well as defining the current status of indoor air quality in Japan. PMID:16541748

  14. Fluidics platform and method for sample preparation

    DOEpatents

    Benner, Henry W.; Dzenitis, John M.

    2016-06-21

    Provided herein are fluidics platforms and related methods for performing integrated sample collection and solid-phase extraction of a target component of the sample all in one tube. The fluidics platform comprises a pump, particles for solid-phase extraction and a particle-holding means. The method comprises contacting the sample with one or more reagents in a pump, coupling a particle-holding means to the pump and expelling the waste out of the pump while the particle-holding means retains the particles inside the pump. The fluidics platform and methods herein described allow solid-phase extraction without pipetting and centrifugation.

  15. Dynamic Method for Identifying Collected Sample Mass

    NASA Technical Reports Server (NTRS)

    Carson, John

    2008-01-01

    G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  16. Feasibility Research on Alternative Approaches for Sampling and Extraction Methods in the TO-4A Method for Pesticides in Ambient Air with Analysis by GC/MS and LC/MS/MS

    EPA Science Inventory

    This compilation of methods is the result of a Regional Methods project between the U.S. Environmental Protection Agency Region 4 and the EPA’s Office of Research and Development. The research leading to these methods was conducted in response to an observed need to update an EPA...

  17. Innovative methods for inorganic sample preparation

    SciTech Connect

    Essling, A.M.; Huff, E.A.; Graczyk, D.G.

    1992-04-01

    Procedures and guidelines are given for the dissolution of a variety of selected materials using fusion, microwave, and Parr bomb techniques. These materials include germanium glass, corium-concrete mixtures, and zeolites. Emphasis is placed on sample-preparation approaches that produce a single master solution suitable for complete multielement characterization of the sample. In addition, data are presented on the soil microwave digestion method approved by the Environmental Protection Agency (EPA). Advantages and disadvantages of each sample-preparation technique are summarized.

  18. Ozone measurement system for NASA global air sampling program

    NASA Technical Reports Server (NTRS)

    Tiefermann, M. W.

    1979-01-01

    The ozone measurement system used in the NASA Global Air Sampling Program is described. The system uses a commercially available ozone concentration monitor that was modified and repackaged so as to operate unattended in an aircraft environment. The modifications required for aircraft use are described along with the calibration techniques, the measurement of ozone loss in the sample lines, and the operating procedures that were developed for use in the program. Based on calibrations with JPL's 5-meter ultraviolet photometer, all previously published GASP ozone data are biased high by 9 percent. A system error analysis showed that the total system measurement random error is from 3 to 8 percent of reading (depending on the pump diaphragm material) or 3 ppbv, whichever are greater.

  19. INDOOR AIR SAMPLING AND MUTAGENICITY STUDIES OF EMISSIONS FROM UNVENTED COAL COMBUSTION (JOURNAL VERSION)

    EPA Science Inventory

    The purpose of the study is to develop sampling strategies and bioassay methods for indoor air in homes, the authors developed a medium-volume sampler to collect the <10 - micrometers particulate matter and semivolatile organics, and used high-volume particulate sampler for compa...

  20. Systems and methods for sample analysis

    SciTech Connect

    Cooks, Robert Graham; Li, Guangtao; Li, Xin; Ouyang, Zheng

    2015-01-13

    The invention generally relates to systems and methods for sample analysis. In certain embodiments, the invention provides a system for analyzing a sample that includes a probe including a material connected to a high voltage source, a device for generating a heated gas, and a mass analyzer.

  1. Systems and methods for sample analysis

    SciTech Connect

    Cooks, Robert Graham; Li, Guangtao; Li, Xin; Ouyang, Zheng

    2015-10-20

    The invention generally relates to systems and methods for sample analysis. In certain embodiments, the invention provides a system for analyzing a sample that includes a probe including a material connected to a high voltage source, a device for generating a heated gas, and a mass analyzer.

  2. Determination of radiocarbon in stratospheric CO2, obtained through AirCore sampling.

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Chen, Huilin; Been, Henk A.; Kivi, Rigel; Meijer, Harro A. J.

    2016-04-01

    The concentration of Greenhouse Gases (GHG), with carbon dioxide as the most prominent example, has been and still is increasing, predominantly due to emissions from fossil fuel combustion. CO2 is also the most important component of the global carbon cycle. Among other tracers, radiocarbon (Carbon-14) is a unique and an important atmospheric tracer used in the understanding of the global carbon cycle. Radiocarbon is a naturally occurring isotope (radioactive, t 1/2 = 5730 ± 40 years) of carbon produced through the interaction of thermalized neutrons and nitrogen in the upper atmosphere. Generally, for performing atmospheric radiocarbon measurements in the higher atmosphere, large samples (few liters of air) were collected using aircrafts and balloons. However, collecting stratospheric samples on a regular basis for radiocarbon analysis is extremely expensive. Here we describe the determination of radiocarbon concentrations in stratospheric CO2, collected using AirCore sampling. AirCore is an innovative sampling technique for obtaining vertical atmospheric profiles and, in Europe, is done on a regular basis at Sodankylä, Finland for CO2, CH4 and CO. The stratospheric parts of two such AirCore profiles were used in this study as a proof-of-principle. CO2 from the stratospheric air samples were extracted and converted to elemental carbon, which were then measured at the Accelerator Mass Spectrometric (AMS) facility of the Centre for Isotope Research (CIO) at the University of Groningen. The stratospheric part of the AirCore profile was divided into six sections, each contained approximately 10 μg C. A detailed description of the extraction, graphitization, AMS analysis and the derivation of the stratospheric radiocarbon profile will be the main focus. Through our results, we will show that AirCore is a viable sampling method for performing high-precision radiocarbon measurements of stratospheric CO2 with reasonably good spatial resolution on a regular basis

  3. Curve fitting air sample filter decay curves to estimate transuranic content.

    PubMed

    Hayes, Robert B; Chiou, Hung Cheng

    2004-01-01

    By testing industry standard techniques for radon progeny evaluation on air sample filters, a new technique is developed to evaluate transuranic activity on air filters by curve fitting the decay curves. The industry method modified here is simply the use of filter activity measurements at different times to estimate the air concentrations of radon progeny. The primary modification was to not look for specific radon progeny values but rather transuranic activity. By using a method that will provide reasonably conservative estimates of the transuranic activity present on a filter, some credit for the decay curve shape can then be taken. By carrying out rigorous statistical analysis of the curve fits to over 65 samples having no transuranic activity taken over a 10-mo period, an optimization of the fitting function and quality tests for this purpose was attained. PMID:14695010

  4. Environmental Asbestos Assessment Manual: Superfund Method for the Determination of Asbestos in Ambient Air, Part 1: Method

    EPA Science Inventory

    This is a sampling and analysis method for the determination of asbestos in air. Samples are analyzed by transmission electron microscopy (TEM). Although a small subset of samples are to be prepared using a direct procedure, the majority of samples analyzed using this method wil...

  5. Solubility testing of actinides on breathing-zone and area air samples

    SciTech Connect

    Metzger, R.L.; Jessop, B.H.; McDowell, B.L.

    1996-02-01

    A solubility testing method for several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALS{reg_sign}) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of U{sub 3}O{sub 8}. Profiles developed for U{sub 3}O{sub 8} samples show good agreement with in vitro and in vivo tests performed by other investigators on samples from the same uranium mills.

  6. Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2008-04-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

  7. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2009-01-23

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

  8. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 6 2011-07-01 2011-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  9. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  10. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 6 2012-07-01 2012-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  11. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA...

  12. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Samples of Air Force FOIA processing documents. 806.27 Section 806.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE ADMINISTRATION AIR FORCE FREEDOM OF INFORMATION ACT PROGRAM § 806.27 Samples of Air Force FOIA processing documents. (a) This section...

  13. Development and validation by accuracy profile of a method for the analysis of monoterpenes in indoor air by active sampling and thermal desorption-gas chromatography-mass spectrometry.

    PubMed

    Marlet, Christelle; Lognay, Georges

    2010-09-15

    The technique of thermal desorption (TD)-GC/MS was evaluated for the measurement of monoterpenes in indoor air. The validation strategy was intentionally oriented towards routine use and the reliability of the method rather than extreme performance. For this reason, validation by accuracy profile was chosen. The accuracy profile procedure, which is based on the concept of total error (bias+standard deviation), guarantees that a known proportion of future results obtained with the method will be within acceptance limits. For all the compounds tested in the present study, alpha-pinene, alpha-terpineol, beta-pinene, d-limonene, Delta(3)-carene, camphene, 1,8-cineole, p-cymene, linalool, but not in the case of carvone, the accuracy profile procedure established that at least 95% of the future results obtained would be within the +/-15% acceptance limits of the validated method over the whole defined concentration range. Other parameters, such as selectivity, recovery, repeatability, stability of the molecules of interest and the effect of temperature, were also determined. The performance of the described method was finally evaluated by the analysis of indoor air from new timber frame constructions. PMID:20801323

  14. Bias in air sampling techniques used to measure inhalation exposure.

    PubMed

    Cohen, B S; Harley, N H; Lippmann, M

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and "mini hi-volume" samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. We conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages. PMID:6720582

  15. Bias in air sampling techniques used to measure inhalation exposure

    SciTech Connect

    Cohen, B.S.; Harley, N.H.; Lippmann, M.

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and mini hi-volume samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. The authors conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  16. Valveless sampling of ambient air for analysis by capillary gas chromatography

    SciTech Connect

    Stephens, E.R. )

    1989-09-01

    A method for the high resolution, high sensitivity analysis of polluted air for individual organic compounds is described. Samples collected from 50 mL of ambient air at 87 K (liquid argon) are injected without use of a valve into a silica capillary column which is then temperature programmed from {minus}30{degree}C to 180{degree}C. Hydrocarbons (4 to 10 carbons) as well as carbonyl compounds, chlorinated compounds and terpenes can be identified and quantified. The detection limit, not strongly dependent on carbon number, is estimated to be 0.3 ppbc in a 50 mL sample. Use of small samples eliminates the need to remove water vapor, a procedure which might jeopardize sample integrity.

  17. Mathematical Estimation of the Level of Microbial Contamination on Spacecraft Surfaces by Volumetric Air Sampling

    PubMed Central

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model. PMID:4151118

  18. Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

    NASA Technical Reports Server (NTRS)

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

  19. Method for sampling sub-micron particles

    DOEpatents

    Gay, Don D.; McMillan, William G.

    1985-01-01

    Apparatus and method steps for collecting sub-micron sized particles include a collection chamber and cryogenic cooling. The cooling is accomplished by coil tubing carrying nitrogen in liquid form, with the liquid nitrogen changing to the gas phase before exiting from the collection chamber in the tubing. Standard filters are used to filter out particles of diameter greater than or equal to 0.3 microns; however the present invention is used to trap particles of less than 0.3 micron in diameter. A blower draws air to said collection chamber through a filter which filters particles with diameters greater than or equal to 0.3 micron. The air is then cryogenically cooled so that moisture and sub-micron sized particles in the air condense into ice on the coil. The coil is then heated so that the ice melts, and the liquid is then drawn off and passed through a Buchner funnel where the liquid is passed through a Nuclepore membrane. A vacuum draws the liquid through the Nuclepore membrane, with the Nuclepore membrane trapping sub-micron sized particles therein. The Nuclepore membrane is then covered on its top and bottom surfaces with sheets of Mylar.RTM. and the assembly is then crushed into a pellet. This effectively traps the sub-micron sized particles for later analysis.

  20. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, G.J.; Motes, B.G.; Bird, S.K.; Kotter, D.K.

    1996-03-26

    Apparatus for obtaining a whole gas sample, is composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method is described for obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant. 3 figs.

  1. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, Gary J.; Motes, Billy G.; Bird, Susan K.; Kotter, Dale K.

    1996-01-01

    Apparatus for obtaining a whole gas sample, composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method of obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant.

  2. Fluidics platform and method for sample preparation and analysis

    SciTech Connect

    Benner, W. Henry; Dzenitis, John M.; Bennet, William J.; Baker, Brian R.

    2014-08-19

    Herein provided are fluidics platform and method for sample preparation and analysis. The fluidics platform is capable of analyzing DNA from blood samples using amplification assays such as polymerase-chain-reaction assays and loop-mediated-isothermal-amplification assays. The fluidics platform can also be used for other types of assays and analyzes. In some embodiments, a sample in a sealed tube can be inserted directly. The following isolation, detection, and analyzes can be performed without a user's intervention. The disclosed platform may also comprises a sample preparation system with a magnetic actuator, a heater, and an air-drying mechanism, and fluid manipulation processes for extraction, washing, elution, assay assembly, assay detection, and cleaning after reactions and between samples.

  3. GAS CHROMATOGRAPHY/MATRIX ISOLATION - INFRARED SPECTROMETRY FOR AIR SAMPLE ANALYSIS

    EPA Science Inventory

    This report describes the application of gas chromatography/matrix- solation infrared (GC/MI-IR) spectrometry to the analysIs of environmental air sample extracts. Samples that were analyzed include extracts from woodsmoke-impacted air, XAD-2 blanks, indoor air, and carpet sample...

  4. Ultrasonic extraction and field-portable anodic stripping voltammetry for the determination of lead in workplace air samples.

    PubMed

    Ashley, K; Mapp, K J; Millson, M

    1998-10-01

    An on-site, field-portable analytical method for the determination of lead in workplace air samples, based on the use of ultrasonic extraction and anodic stripping voltammetry (ASV), was evaluated. Workplace air samples were obtained using a standard method involving particulate collection onto mixed cellulose ester membrane filters. Samples were collected at work sites where airborne particulates were generated from the abrasive blasting of lead-containing paint on highway bridges. Ultrasonic extraction (UE) of air filter samples in diluted nitric acid, followed by portable ASV, was used for the determination of lead. Also, performance evaluation samples consisting of reference materials of known lead concentration were subjected to the UE-ASV procedure for lead determination. Confirmatory analyses of the air filters and performance evaluation samples subjected to the UE-ASV lead measurement method were conducted by hotplate digestion in concentrated nitric acid and 30% hydrogen peroxide, followed by inductively coupled plasma-atomic emission spectrometric (ICP-AES) determination of lead. Recoveries of lead from performance evaluation materials (when using the UE-ASV method) were found to be quantitative. The performance of the UE-ASV method for lead in air filters was found to be acceptable, as evaluated by comparison with results from hotplate strong acid digestion followed by ICP-AES analysis. Based on the results of this study, the ultrasonic extraction/portable ASV procedure demonstrates potential for the on-site determination of lead in personal breathing zone and area air samples. PMID:9794065

  5. An Autosampler and Field Sample Carrier for Maximizing Throughput Using an Open-Air, Surface Sampling Ion Source for MS

    EPA Science Inventory

    A recently developed, commercially available, open-air, surface sampling ion source for mass spectrometers provides individual analyses in several seconds. To realize its full throughput potential, an autosampler and field sample carrier were designed and built. The autosampler ...

  6. Diffusive sampling and measurement of microbial volatile organic compounds in indoor air.

    PubMed

    Araki, A; Eitaki, Y; Kawai, T; Kanazawa, A; Takeda, M; Kishi, R

    2009-10-01

    Microbial volatile organic compounds (MVOC), chemicals emitted from various microorganisms, in indoor air have been of concern in recent years. For large field studies, diffusive samplers are widely used to measure indoor environments. Since the sampling rate of a sampler is a fundamental parameter to calculate concentration, the sampling rates of eight MVOC with diffusive samplers were determined experimentally using a newly developed water-bubbling method: air was supplied to the MVOC-solutions and the vapor collected in an exposure bag, where diffusive and active samplers were placed in parallel for comparison. Correlations between the diffusive and active samplings gave good linear regressions. The sampling rates were 30-35 ml/min and the detection limits were 0.044-0.178 microg/m(3), as determined by GC/MS analysis. Application of the sampling rates in indoor air was validated by parallel sampling of the diffusive and active sampling method. 5% Propan-2-ol/CS(2) was the best solvent to desorb the compounds from absorbents. The procedure was applied to a field study in 41 dwellings. The most frequently detected compounds were hexan-2-one and heptan-2-one, with 97.5% detection rates and geometric mean values of 0.470 and 0.302 microg/m(3), respectively. This study shows that diffusive samplers are applicable to measure indoor MVOC levels. Practical Implications At present, there are still limited reports on indoor Microbial Volatile Organic Compounds (MVOC) levels in general dwellings and occupants' health. Compared with active sampling methods, air sampling using a diffusive sampler is particularly advantageous for use in large field studies due to its smallness, light-size, easy-handling, and cost-effectiveness. In this study, sampling rates of selected MVOC of the diffusive sampler were determined using the water-bubbling method: generating gases by water-bubbling and exposing the diffusive and active samplers at the same time. The obtained sampling rates

  7. Determination of methyl bromide in air samples by headspace gas chromatography

    SciTech Connect

    Woodrow, J.E.; McChesney, M.M.; Seiber, J.N.

    1988-03-01

    Methyl bromide is extensively used in agriculture (4 x 10/sup 6/ kg for 1985 in California alone as a fumigant to control nematodes, weeds, and fungi in soil and insect pests in harvested grains and nuts. Given its low boiling point (3.8/sup 0/C) and high vapor pressure (approx. 1400 Torr at 20/sup 0/C), methyl bromide will readily diffuse if not rigorously contained. Methods for determining methyl bromide and other halocarbons in air vary widely. A common practice is to trap the material from air on an adsorbent, such as polymeric resins, followed by thermal desorption either directly into the analytical instrumentation or after intermediary cryofocusing. While in some cases analytical detection limits were reasonable (parts per million range), many of the published methods were labor intensive and required special handling techniques that precluded high sample throughput. They describe here a method for the sampling and analysis of airborne methyl bromide that was designed to handle large numbers of samples through automating some critical steps of the analysis. The result was a method that allowed around-the-clock operation with a minimum of operator attention. Furthermore, the method was not specific to methyl bromide and could be used to determine other halocarbons in air.

  8. [Spectrum recovery methods for nonuniform sampling interferogram].

    PubMed

    Yao, Tao; Lü, Qun-Bo; Xiangli, Bin; Yuan, Yan

    2010-05-01

    The interferogram acquired by imaging Fourier transform spectrometer (IFTS) can't be used directly and must be recovered. The spectrum recovery processes based on fast Fourier transform (FFT) is the traditional method which is used widely. For some IFTS, the nonuniform sampling of the interferogram is often occurrs. When the aliasing is neglected, the spectrum recovered by traditional method is often distorted. When the spectrum recovery processes based on Fourier transform are used, the precision of the recovered spectrum can be ensured, but the real-time processing requirement can't be satisfied. In order to acquire the precise recovered spectrum of the nonuniform sampled interferogram, the interpolation method and nonuniform fast Fourier transform (NUFFT) method were adopted. For the oversampled interferogram and partial undersampled interferogram, the spectrum recovery methods based on interpolation and NUFFT were presented respectively, and the applicability of these two methods is given. Finally, the computer simulation was performed, and the results indicate that NUFFT method is preferable to interpolation method not for undersampled interferogram but for oversampled interferogram. PMID:20672649

  9. Bayesian individualization via sampling-based methods.

    PubMed

    Wakefield, J

    1996-02-01

    We consider the situation where we wish to adjust the dosage regimen of a patient based on (in general) sparse concentration measurements taken on-line. A Bayesian decision theory approach is taken which requires the specification of an appropriate prior distribution and loss function. A simple method for obtaining samples from the posterior distribution of the pharmacokinetic parameters of the patient is described. In general, these samples are used to obtain a Monte Carlo estimate of the expected loss which is then minimized with respect to the dosage regimen. Some special cases which yield analytic solutions are described. When the prior distribution is based on a population analysis then a method of accounting for the uncertainty in the population parameters is described. Two simulation studies showing how the methods work in practice are presented. PMID:8827585

  10. Mixed species radioiodine air sampling readout and dose assessment system

    DOEpatents

    Distenfeld, Carl H.; Klemish, Jr., Joseph R.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector.

  11. Method and apparatus for sampling low-yield wells

    DOEpatents

    Last, George V.; Lanigan, David C.

    2003-04-15

    An apparatus and method for collecting a sample from a low-yield well or perched aquifer includes a pump and a controller responsive to water level sensors for filling a sample reservoir. The controller activates the pump to fill the reservoir when the water level in the well reaches a high level as indicated by the sensor. The controller deactivates the pump when the water level reaches a lower level as indicated by the sensors. The pump continuously activates and deactivates the pump until the sample reservoir is filled with a desired volume, as indicated by a reservoir sensor. At the beginning of each activation cycle, the controller optionally can select to purge an initial quantity of water prior to filling the sample reservoir. The reservoir can be substantially devoid of air and the pump is a low volumetric flow rate pump. Both the pump and the reservoir can be located either inside or outside the well.

  12. Evaluation of passive air sampler calibrations: Selection of sampling rates and implications for the measurement of persistent organic pollutants in air

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Robson, Matthew; Helm, Paul A.; Diamond, Miriam L.

    2011-04-01

    Polyurethane foam (PUF) passive air samplers (PAS) are a common and highly useful method of sampling persistent organic pollutants (POP) concentrations in air. PAS calibration is necessary to obtain reasonable and comparable semi-quantitative measures of air concentrations. Various methods are found in the literature concerning PAS calibration. 35 studies on PAS use and calibration are examined here, in conjunction with a study involving 10 PAS deployed concurrently in outdoor air with a low-volume air sampler in order to measure the sampling rates of PUF-PAS for polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), polycyclic musks (PCMs), and polycyclic aromatic hydrocarbons (PAHs). Based on this analysis it is recommended that (1) PAS should be assumed to represent bulk rather than gas-phase compound concentrations due to the sampling of particle-bound compounds, (2) calibration of PAS sampling rates is more accurately achieved using an active low-volume air sampler rather than depuration compounds since the former measures gas- and particle-phase compounds and does so continuously over the deployment period of the PAS, and (3) homolog-specific sampling rates based on KOA groupings be used in preference to compound/congener-specific or single sampling rates.

  13. Update on field evaluation of EPA Method CTM-039 (PM2.5 Stack Sampling Method)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Agricultural operations are encountering difficulties complying with current air pollution regulations for particulate matter (PM). These regulations are based on the National Ambient Air Quality Standards, which set maximum concentration limits for ambient air PM. Source sampling for compliance pur...

  14. Preliminary field evaluation of EPA Method CTM-039 (PM2.5 Stack Sampling Method)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Agricultural operations are encountering difficulties complying with current air pollution regulations for particulate matter (PM). These regulations are based on the National Ambient Air Quality Standards which set maximum concentration limits for ambient air PM. Source sampling for compliance purp...

  15. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  16. Air sampling filtration media: Collection efficiency for respirable size-selective sampling

    PubMed Central

    Soo, Jhy-Charm; Monaghan, Keenan; Lee, Taekhee; Kashon, Mike; Harper, Martin

    2016-01-01

    The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min−1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes. PMID:26834310

  17. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi,Shanavaz; Langlois, Richard G.; Venkateswaran, Kodumudi S.

    2011-07-05

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM.TM. on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA.TM., on the 5' end.

  18. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi, Shanavaz; Langlois, Richard G.; Venkateswaran, Kodumudi S.

    2006-08-01

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM, on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA, on the 5' end.

  19. Solubility testing of actinides on breathing-zone and area air samples

    NASA Astrophysics Data System (ADS)

    Metzger, Robert Lawrence

    The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine

  20. Geant4 Simulation of Air Showers using Thinning Method

    NASA Astrophysics Data System (ADS)

    Sabra, Mohammad S.; Watts, John W.; Christl, Mark J.

    2015-04-01

    Simulation of complete air showers induced by cosmic ray particles becomes prohibitive at extreme energies due to the large number of secondary particles. Computing time of such simulations roughly scales with the energy of the primary cosmic ray particle, and becomes excessively large. To mitigate the problem, only small fraction of particles can be tracked and, then, the whole shower is reconstructed based on this sample. This method is called Thinning. Using this method in Geant4, we have simulated proton and iron air showers at extreme energies (E >1016 eV). Secondary particle densities are calculated and compared with the standard simulation program in this field, CORSIKA. This work is supported by the NASA Postdoctoral Program administrated by Oak Ridge Associated Universities.

  1. Method, system and apparatus for monitoring and adjusting the quality of indoor air

    DOEpatents

    Hartenstein, Steven D.; Tremblay, Paul L.; Fryer, Michael O.; Hohorst, Frederick A.

    2004-03-23

    A system, method and apparatus is provided for monitoring and adjusting the quality of indoor air. A sensor array senses an air sample from the indoor air and analyzes the air sample to obtain signatures representative of contaminants in the air sample. When the level or type of contaminant poses a threat or hazard to the occupants, the present invention takes corrective actions which may include introducing additional fresh air. The corrective actions taken are intended to promote overall health of personnel, prevent personnel from being overexposed to hazardous contaminants and minimize the cost of operating the HVAC system. The identification of the contaminants is performed by comparing the signatures provided by the sensor array with a database of known signatures. Upon identification, the system takes corrective actions based on the level of contaminant present. The present invention is capable of learning the identity of previously unknown contaminants, which increases its ability to identify contaminants in the future. Indoor air quality is assured by monitoring the contaminants not only in the indoor air, but also in the outdoor air and the air which is to be recirculated. The present invention is easily adaptable to new and existing HVAC systems. In sum, the present invention is able to monitor and adjust the quality of indoor air in real time by sensing the level and type of contaminants present in indoor air, outdoor and recirculated air, providing an intelligent decision about the quality of the air, and minimizing the cost of operating an HVAC system.

  2. EVALUATION OF SAMPLING METHODS FOR GASEOUS ATMOSPHERIC SAMPLES

    EPA Science Inventory

    A research program was conducted to test and evaluate several alternatives for collecting and transferring samples from the collection site to the laboratory for the analysis of a variety of toxic organic pollutants by gas chromatography (GC). Sample storage media included three ...

  3. Interlaboratory evaluation of cellulosic acid-soluble internal air sampling capsules for multi-element analysis.

    PubMed

    Andrews, Ronnee N; Feng, H Amy; Ashley, Kevin

    2016-01-01

    An interlaboratory study was carried out to evaluate the use of acid-soluble cellulosic air sampling capsules for their suitability in the measurement of trace elements in workplace atmospheric samples. These capsules are used as inserts to perform closed-face cassette sample collection for occupational exposure monitoring. The interlaboratory study was performed in accordance with NIOSH guidelines that describe statistical procedures for evaluating measurement accuracy of air monitoring methods. The performance evaluation materials used consisted of cellulose acetate capsules melded to mixed-cellulose ester filters that were dosed with multiple elements from commercial standard aqueous solutions. The cellulosic capsules were spiked with the following 33 elements of interest in workplace air monitoring: Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, In, K, La, Li, Mg, Mn, Mo, Ni, P, Pb, Sb, Se, Sn, Sr, Te, Ti, Tl, V, W, Y, Zn, Zr. The elemental loading levels were certified by an accredited provider of certified reference materials. Triplicates of media blanks and multielement-spiked capsules at three different elemental loadings were sent to each participating laboratory; the elemental loading levels were not revealed to the laboratories. The volunteer participating laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by inductively coupled plasma atomic emission spectrometry in accordance with NIOSH methods. It was requested that the study participants report their analytical results in units of μg of each target element per internal capsule sample. For the majority of the elements investigated (30 out of 33), the study accuracy estimates obtained satisfied the NIOSH accuracy criterion (A < 25%). This investigation demonstrates the utility of acid-soluble internal sampling capsules for multielement analysis by atomic spectrometry. PMID:26308974

  4. Breakthrough of 1,3-dichloropropene and chloropicrin from 600 mg XAD-4 air sampling tubes

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Accurately measuring air concentrations of agricultural fumigants is important for the regulation of air quality. Understanding the conditions under which sorbent tubes can effectively retain such fumigants during sampling is critical in mitigating chemical breakthrough from the tubes and facilitati...

  5. Well purge and sample apparatus and method

    DOEpatents

    Schalla, Ronald; Smith, Ronald M.; Hall, Stephen H.; Smart, John E.; Gustafson, Gregg S.

    1995-01-01

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly with a packer, pump and exhaust, that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. The packer is positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion.

  6. Well purge and sample apparatus and method

    DOEpatents

    Schalla, R.; Smith, R.M.; Hall, S.H.; Smart, J.E.; Gustafson, G.S.

    1995-10-24

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly with a packer, pump and exhaust, that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. The packer is positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion. 8 figs.

  7. SAMPLING AND ANALYSIS OF PCDDS AND PCDFS IN STATIONARY SOURCE EMISSION AIR SAMPLES

    EPA Science Inventory

    Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzo-furans (PCDFs) are two classes of extremely toxic compounds produced and emitted into the environment as a result of combustion processes. lthough no standard method for sampling or analysis of PCDDs and PCDFs ...

  8. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  9. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  10. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  11. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  12. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  13. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  14. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  15. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  16. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  17. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  18. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  19. 30 CFR 71.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approved sampling devices; operation; air... OF UNDERGROUND COAL MINES Sampling Procedures § 71.205 Approved sampling devices; operation; air... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  20. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approved sampling devices; operation; air... DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate... flowrate as prescribed by the Secretary and the Secretary of Health and Human Services for the...

  1. 30 CFR 70.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... § 70.205 Approved sampling devices; operation; air flowrate. (a) Sampling devices approved in... Secretary of Health and Human Services for the particular device. (b) Except as provided in paragraph (d)...

  2. RADIOMETRIC METHOD FOR THE DETERMINATION OF URANIUM IN SOIL AND AIR: SINGLE-LABORATORY EVALUATION AND INTERLABORATORY COLLABORATIVE STUDY

    EPA Science Inventory

    Results of a single-laboratory evaluation and an interlaboratory collaborative study of a method for determining uranium isotopes in soil and air samples are presented. The method is applicable to 10-gram soil samples and to both glass fiber and polystyrene air filter samples. Sa...

  3. Laboratory validation and field verification of a new passive air monitoring badge for sampling ethylene oxide in air.

    PubMed

    Kring, E V; Damrell, D J; Basilio, A N; McGibney, P D; Douglas, J J; Henry, T J; Ansul, G R

    1984-10-01

    A new diffusion colorimetric air monitoring badge for sampling ethylene oxide is described. The Du Pont Pro-Tek C-70 badge has been laboratory validated over the range of 4-375 ppm-hours (0.5-47 ppm on an 8-hour TWA) using standard spectrophotometer readout in 1 centimeter (10 mm) cells. The lower range can be extended to 2 ppm-hours (0.25 ppm) by using 4 cm (40 mm) cells. The badge has an overall sampling and analytical method accuracy of +/- 13.5%. It meets NIOSH accuracy criteria and has a mean coefficient of variation CVT = 0.059. The badge has no temperature, pressure, relative humidity or face velocity effects over practical ranges. The response time is adequate to sample peak concentrations over short time periods. The badge may be used to determine ambient formaldehyde levels if suspected to be present along with ethylene oxide. Badges are shown to agree very well with the industry accepted and proposed ASTM pump/charcoal tube method in three extensive plant field tests. Badges were more precise than the charcoal tube/pump method in all field tests conducted. PMID:6496316

  4. Combustor air flow control method for fuel cell apparatus

    DOEpatents

    Clingerman, Bruce J.; Mowery, Kenneth D.; Ripley, Eugene V.

    2001-01-01

    A method for controlling the heat output of a combustor in a fuel cell apparatus to a fuel processor where the combustor has dual air inlet streams including atmospheric air and fuel cell cathode effluent containing oxygen depleted air. In all operating modes, an enthalpy balance is provided by regulating the quantity of the air flow stream to the combustor to support fuel cell processor heat requirements. A control provides a quick fast forward change in an air valve orifice cross section in response to a calculated predetermined air flow, the molar constituents of the air stream to the combustor, the pressure drop across the air valve, and a look up table of the orifice cross sectional area and valve steps. A feedback loop fine tunes any error between the measured air flow to the combustor and the predetermined air flow.

  5. High sensitivity gamma spectrometry of air samples near SRS during 1985-1995

    SciTech Connect

    Winn, W.G.; Cadieux, J.R.

    1997-07-01

    High sensitivity gamma analysis of off-site air samples near the Savannah River Site (SRS) is achieved by collecting large volume air samples for analysis by ultra-low-level gamma spectrometry. A review of the 1985-1995 measurements has highlighted local and distant releases of man-made radionuclides, along with cosmogenic radionuclides which correlate with both solar and seasonal phenomena. Measurements typically involve 2-day air collection of a 70,000 m{sup 3} sample on a 51 cm x 51 cm cellulose filter using a high-capacity pump. Short-lived radon background activity is allowed to decay a few days, and then the filter is configured into a smaller calibrated volume and counted 1-3 days on a 30 percent-efficient HPGe in the Ultra-Low-Level Counting Facility. Representative detection limits for this method are shown in Table 1, and even lower limits are achievable by counting on the low-background 160 percent-efficient HPGe of the Underground Counting Facility.

  6. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING AIR SAMPLES FOR ANALYSIS OF POLAR PERSISTENT ORGANIC POLLUTANTS (SOP-5.13)

    EPA Science Inventory

    The method for extracting and preparing indoor and outdoor air samples for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the preparation of samples that are to be analyzed by gas chromatography/mass spectrometry.

  7. Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns.

    PubMed Central

    Whyatt, Robin M; Barr, Dana B; Camann, David E; Kinney, Patrick L; Barr, John R; Andrews, Howard F; Hoepner, Lori A; Garfinkel, Robin; Hazi, Yair; Reyes, Andria; Ramirez, Judyth; Cosme, Yesenia; Perera, Frederica P

    2003-01-01

    We have measured 29 pesticides in plasma samples collected at birth between 1998 and 2001 from 230 mother and newborn pairs enrolled in the Columbia Center for Children's Environmental Health prospective cohort study. Our prior research has shown widespread pesticide use during pregnancy among this urban minority cohort from New York City. We also measured eight pesticides in 48-hr personal air samples collected from the mothers during pregnancy. The following seven pesticides were detected in 48-83% of plasma samples (range, 1-270 pg/g): the organophosphates chlorpyrifos and diazinon, the carbamates bendiocarb and 2-isopropoxyphenol (metabolite of propoxur), and the fungicides dicloran, phthalimide (metabolite of folpet and captan), and tetrahydrophthalimide (metabolite of captan and captafol). Maternal and cord plasma levels were similar and, except for phthalimide, were highly correlated (p < 0.001). Chlorpyrifos, diazinon, and propoxur were detected in 100% of personal air samples (range, 0.7-6,010 ng/m(3)). Diazinon and propoxur levels were significantly higher in the personal air of women reporting use of an exterminator, can sprays, and/or pest bombs during pregnancy compared with women reporting no pesticide use or use of lower toxicity methods only. A significant correlation was seen between personal air level of chlorpyrifos, diazinon, and propoxur and levels of these insecticides or their metabolites in plasma samples (maternal and/or cord, p < 0.05). The fungicide ortho-phenylphenol was also detected in 100% of air samples but was not measured in plasma. The remaining 22 pesticides were detected in 0-45% of air or plasma samples. Chlorpyrifos, diazinon, propoxur, and bendiocarb levels in air and/or plasma decreased significantly between 1998 and 2001. Findings indicate that pesticide exposures are frequent but decreasing and that the pesticides are readily transferred to the developing fetus during pregnancy. PMID:12727605

  8. System and Method for Isolation of Samples

    NASA Technical Reports Server (NTRS)

    Zhang, Ye (Inventor); Wu, Honglu (Inventor)

    2014-01-01

    Systems and methods for isolating samples are provided. The system comprises a first membrane and a second membrane disposed within an enclosure. First and second reservoirs can also be disposed within the enclosure and adapted to contain one or more reagents therein. A first valve can be disposed within the enclosure and in fluid communication with the first reservoir, the second reservoir, or both. The first valve can also be in fluid communication with the first or second membranes or both. The first valve can be adapted to selectively regulate the flow of the reagents from the first reservoir, through at least one of the first and second membranes, and into the second reservoir.

  9. Field evaluation of sampling and analysis for organic pollutants in indoor air. Project summary

    SciTech Connect

    Chuang, J.C.; Mack, G.A.; Stockrahm, J.W.; Hannan, S.W.; Bridges, C.

    1988-09-01

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in residential air.

  10. Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air.

    PubMed

    Attari, Seyed Ghavameddin; Bahrami, Abdolrahman; Shahna, Farshid Ghorbani; Heidari, Mahmoud

    2014-01-01

    A green, environmental friendly and sensitive method for determination of volatile organohalogen compounds was described in this paper. The method is based on a homemade sol-gel single-walled carbon nanotube/silica composite coated solid-phase microextraction to develop for sampling and analysis of Carbon tetrachloride, Benzotrichloride, Chloromethyl methyl ether and Trichloroethylene in air. Application of this method was investigated under different laboratory conditions. Predetermined concentrations of each analytes were prepared in a home-made standard chamber and the influences of experimental parameters such as temperature, humidity, extraction time, storage time, desorption temperature, desorption time and the sorbent performance were investigated. Under optimal conditions, the use of single-walled carbon nanotube/silica composite fiber showed good performance, high sensitive and fast sampling of volatile organohalogen compounds from air. For linearity test the regression correlation coefficient was more than 98% for analyte of interest and linear dynamic range for the proposed fiber and the applied Gas Chromatography-Flame Ionization Detector technique was from 1 to 100 ngmL(-1). Method detection limits ranged between 0.09 to 0.2 ngmL(-1) and method quantification limits were between 0.25 and 0.7 ngmL(-1). Single-walled carbon nanotube/silica composite fiber was highly reproducible, relative standard deviations were between 4.3 to 11.7 percent. PMID:25279223

  11. Rapid on-site air sampling with a needle extraction device for evaluating the indoor air environment in school facilities.

    PubMed

    Inoue, Mitsuru; Mizuguchi, Ayako; Ueta, Ikuo; Takahashi, Kazuya; Saito, Yoshihiro

    2013-01-01

    A rapid on-site air sampling technique was developed with a miniaturized needle-type sample preparation device for a systematic evaluation of the indoor air environments in school facilities. With the in-needle extraction device packed with a polymer particle of divinylbenzene and activated carbon particles, various types of volatile organic compounds (VOCs) were successfully extracted. For evaluating the indoor air qualities in school facilities, air samples in renovated rooms using organic solvent as a thinner of the paint were analyzed along with measurements of several VOCs in indoor air samples taken in newly built primary schools mainly using low-VOCs materials. After periodical renovation/maintenance, the time-variation profile of typical VOCs found in the school facilities has also been monitored. From the results, it could be observed that the VOCs in most of the rooms in these primary schools were at a quite low level; however, a relatively higher concentration of VOCs was found in some specially designed rooms, such as music rooms. In addition, some non-regulated compounds, including benzyl alcohol and branched alkanes, were detected in these primary schools. The results showed a good applicability of the needle device to indoor air analysis in schools, suggesting a wide range of future employment of the needle device, especially for indoor air analysis in other types of facilities and rooms including hospitals and hotels. PMID:23665624

  12. Spectral fingerprinting of polycyclic aromatic hydrocarbons in high-volume ambient air samples by constant energy synchronous luminescence spectroscopy

    USGS Publications Warehouse

    Kerkhoff, M.J.; Lee, T.M.; Allen, E.R.; Lundgren, D.A.; Winefordner, J.D.

    1985-01-01

    A high-volume sampler fitted with a glass-fiber filter and backed by polyurethane foam (PUF) was employed to collect airborne particulate and gas-phase polycylic aromatic hydrocarbons (PAHs) in ambient air. Samples were collected from four sources representing a range of environmental conditions: gasoline engine exhaust, diesel engine exhaust, air near a heavily traveled interstate site, and air from a moderately polluted urban site. Spectral fingerprints of the unseparated particulate and gas-phase samples were obtained by constant energy synchronous luminescence spectroscopy (CESLS). Five major PAHs in the gas-phase extracts were characterized and estimated. The compatibility of a high-volume sampling method using polyurethane foam coupled with CESLS detection is explored for use as a screening technique for PAHs in ambient air. ?? 1985 American Chemical Society.

  13. Acoustic method for measuring air temperature and humidity in rooms

    NASA Astrophysics Data System (ADS)

    Kanev, N. G.

    2014-05-01

    A method is proposed to determine air temperature and humidity in rooms with a system of sound sources and receivers, making it possible to find the sound velocity and reverberation time. Nomograms for determining the air temperature and relative air humidity are constructed from the found sound velocity and time reverberation values. The required accuracy of measuring these parameters is estimated.

  14. Sampling size in the verification of manufactured-supplied air kerma strengths

    SciTech Connect

    Ramos, Luis Isaac; Martinez Monge, Rafael

    2005-11-15

    Quality control mandate that the air kerma strengths (S{sub K}) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to an a priori statistical level of uncertainty. The results are based on the assumption that the S{sub K} has a normal distribution. To demonstrate this, the S{sub K} of each of the seeds measured was corrected to ensure that the average S{sub K} of its sample remained the same. In this process 2030 results were collected and analyzed using a normal plot. In our opinion, the number of seeds sampled should be determined beforehand according to an a priori level of statistical uncertainty.

  15. Toxicological Assessment of ISS Air Quality: Contingency Sampling - February 2013

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2013-01-01

    Two grab sample containers (GSCs) were collected by crew members onboard ISS in response to a vinegar-like odor in the US Lab. On February 5, the first sample was collected approximately 1 hour after the odor was noted by the crew in the forward portion of the Lab. The second sample was collected on February 22 when a similar odor was noted and localized to the end ports of the microgravity science glovebox (MSG). The crewmember removed a glove from the MSG and collected the GSC inside the glovebox volume. Both samples were returned on SpaceX-2 for ground analysis.

  16. The Halving Method for Sample Quartiles

    ERIC Educational Resources Information Center

    Joarder, Anwar H.

    2003-01-01

    An attempt is made to put the notion of sample quartiles on a mathematical footing in the light of ranks of observations, and equisegmentation property that the quartiles divide ordered sample observations into four segments leaving the same number of observations in each if all the observations are distinct. Sample quartiles provided by the…

  17. Biomimetic air sampling for detection of low concentrations of molecules and bioagents : LDRD 52744 final report.

    SciTech Connect

    Hughes, Robert Clark

    2003-12-01

    Present methods of air sampling for low concentrations of chemicals like explosives and bioagents involve noisy and power hungry collectors with mechanical parts for moving large volumes of air. However there are biological systems that are capable of detecting very low concentrations of molecules with no mechanical moving parts. An example is the silkworm moth antenna which is a highly branched structure where each of 100 branches contains about 200 sensory 'hairs' which have dimensions of 2 microns wide by 100 microns long. The hairs contain about 3000 pores which is where the gas phase molecules enter the aqueous (lymph) phase for detection. Simulations of diffusion of molecules indicate that this 'forest' of hairs is 'designed' to maximize the extraction of the vapor phase molecules. Since typical molecules lose about 4 decades in diffusion constant upon entering the liquid phase, it is important to allow air diffusion to bring the molecule as close to the 'sensor' as possible. The moth acts on concentrations as low as 1000 molecules per cubic cm. (one part in 1e16). A 3-D collection system of these dimensions could be fabricated by micromachining techniques available at Sandia. This LDRD addresses the issues involved with extracting molecules from air onto micromachined structures and then delivering those molecules to microsensors for detection.

  18. Indoor air sampling and mutagenicity studies related to emissions from unvented coal combustion

    SciTech Connect

    Mumford, J.L.; Harris, D.B.; Williams, K.; Chuang, J.C.; Cooke, M.

    1986-07-01

    The purpose of the study is to develop sampling strategies and bioassay methods for indoor air in homes. The work reported here was conducted to prepare for a joint U.S.-China field study in Xuan Wei County, Yunnan Province, southern China, where the residents traditionally burn coal or wood for domestic cooking and heating without flue ventilation. These residents are exposed daily to high levels of combustion smoke and have unusually high lung cancer mortality rates, the women's rate the highest in China, and the men's rate among the highest. The paper reports the chemical and biological characterization of coal emissions from a simulated combustion laboratory.

  19. Filter for on-line air monitor unaffected by radon progeny and method of using same

    DOEpatents

    Phillips, Terrance D.; Edwards, Howard D.

    1999-01-01

    An apparatus for testing air having contaminants and radon progeny therein. The apparatus includes a sampling box having an inlet for receiving the air and an outlet for discharging the air. The sampling box includes a filter made of a plate of sintered stainless steel. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough. A method of testing air having contaminants and radon progeny therein. The method includes providing a testing apparatus that has a sampling box with an inlet for receiving the air and an outlet for discharging the air, and has a sintered stainless steel filter disposed within said sampling box; drawing air from a source into the sampling box using a vacuum pump; passing the air through the filter; monitoring the contaminants trapped by the filter; and providing an alarm when a selected level of contaminants is reached. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough.

  20. Cool-Water Coal Gasification Program: Environmental Monitoring Plan Commissioning Phase, final report. Volume 1. Technical report. Volume 2. Appendix A - HRSG (heat recovery steam generator) stack-testing results. Volume 3. Appendix B - analytical results. Appendix C - sampling analytical methods. Appendix D - ambient air monitoring data. Volume 4. Appendix E - quality assurance/quality control. Technical report

    SciTech Connect

    Not Available

    1985-10-11

    The Cool Water Coal Gasification Program (CWCGP) began electrical production under the terms of the Price Guarantee Commitment with the U.S. Synthetic Fuels Corporation (SFC) on June 24, 1984. An Environmental Monitoring Plan (EMP) approved by the SFC was initiated at that time. The Commissioning Phase, the first of four phases of the EMP, was conducted from June 24 through December 31, 1984. Sampling and analysis of compliance and supplemental parameters produced over 1100 samples and 8500 data points from 17 aqueous, ten gaseous, and four solid sampling streams. The technical report includes a description of the CWCGP process as it was operated during the Commissioning Phase, a summary of process changes that occurred during the period, their effect on the environmental monitoring effort, and details of pollution-control testing (Appendix A), data calculations (Appendix B), analytical methods and results (Appendix C), ambient-air-monitoring data (Appendix D), and quality-assurance/quality-control program results (Appendix E).

  1. Secondary air injection system and method

    DOEpatents

    Wu, Ko-Jen; Walter, Darrell J.

    2014-08-19

    According to one embodiment of the invention, a secondary air injection system includes a first conduit in fluid communication with at least one first exhaust passage of the internal combustion engine and a second conduit in fluid communication with at least one second exhaust passage of the internal combustion engine, wherein the at least one first and second exhaust passages are in fluid communication with a turbocharger. The system also includes an air supply in fluid communication with the first and second conduits and a flow control device that controls fluid communication between the air supply and the first conduit and the second conduit and thereby controls fluid communication to the first and second exhaust passages of the internal combustion engine.

  2. Air/superfund national technical guidance study series. Air emissions from area sources: Estimating soil and soil-gas sample number requirements. Final report

    SciTech Connect

    Westbrook, W.

    1993-03-01

    The document provides guidance regarding the necessary number of soil gas or soil samples needed to estimate air emissions from area sources. The Manual relies heavily on statistical methods discussed in Appendix C of Volume II of Air/Superfund National Technical Guidance Study Series (EPA 1990) and Chapter 9 of SW-846 (EPA 1986). The techniques in the manual are based on recognizing the inhomgeniety of an area, by observation or screening samples, before samples are taken. Each of the identified zones are then sampled, using random sampling techniques, and statistics calculated separately for each zone before combining the statistics to provide an estimate for the entire area. The statistical techniques presented may also be used to analyze other types of data and provide measures such as mean, variance, and standard deviation. The methods presented in the Manual are based on small sample methods. Application of the methods to data which are appropriately analyzed by large sample methods or to data which is not normally distributed will give erroneous results.

  3. Air cooling : an experimental method of evaluating the cooling effect of air streams on air-cooled cylinders

    NASA Technical Reports Server (NTRS)

    Alcock, J F

    1927-01-01

    In this report is described an experimental method which the writer has evolved for dealing with air-cooled engines, and some of the data obtained by its means. Methods of temperature measurement and cooling are provided.

  4. Method and apparatus for extracting water from air

    DOEpatents

    Spletzer, Barry L.; Callow, Diane Schafer; Marron, Lisa C.; Salton, Jonathan R.

    2002-01-01

    The present invention provides a method and apparatus for extracting liquid water from moist air using minimal energy input. The method comprises compressing moist air under conditions that foster the condensation of liquid water. The air can be decompressed under conditions that do not foster the vaporization of the condensate. The decompressed, dried air can be exchanged for a fresh charge of moist air and the process repeated. The liquid condensate can be removed for use. The apparatus can comprise a compression chamber having a variable internal volume. An intake port allows moist air into the compression chamber. An exhaust port allows dried air out of the compression chamber. A condensation device fosters condensation at the desired conditions. A condensate removal port allows liquid water to be removed.

  5. Method and apparatus for extracting water from air

    DOEpatents

    Spletzer, Barry L.

    2001-01-01

    The present invention provides a method and apparatus for extracting liquid water from moist air using minimal energy input. The method comprises compressing moist air under conditions that foster the condensation of liquid water (ideally isothermal to a humidity of 1.0, then adiabatic thereafter). The air can be decompressed under conditions that do not foster the vaporization of the condensate. The decompressed, dried air can be exchanged for a fresh charge of moist air and the process repeated. The liquid condensate can be removed for use. The apparatus can comprise a compression chamber having a variable internal volume. An intake port allows moist air into the compression chamber. An exhaust port allows dried air out of the compression chamber. A condensation device fosters condensation at the desired conditions. A condensate removal port allows liquid water to be removed.

  6. Recent advances in thermal desorption-gas chromatography-mass spectrometery method to eliminate the matrix effect between air and water samples: application to the accurate determination of Henry's law constant.

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2014-05-16

    Accurate values for the Henry's law constants are essential to describe the environmental dynamics of a solute, but substantial errors are recognized in many reported data due to practical difficulties in measuring solubility and/or vapor pressure. Despite such awareness, validation of experimental approaches has scarcely been made. An experimental approach based on thermal desorption-gas chromatography-mass spectrometery (TD-GC-MS) method was developed to concurrently allow the accurate determination of target compounds from the headspace and aqueous samples in closed equilibrated system. The analysis of six aromatics and eight non-aromatic oxygenates was then carried out in a static headspace mode. An estimation of the potential bias and mass balance (i.e., sum of mass measured individually from gas and liquid phases vs. the mass initially added to the system) demonstrates compound-specific phase dependency so that the best results are obtained by aqueous (less soluble aromatics) and headspace analysis (more soluble non-aromatics). Accordingly, we were able to point to the possible sources of biases in previous studies and provide the best estimates for the Henry's constants (Matm(-1)): benzene (0.17), toluene (0.15), p-xylene (0.13), m-xylene (0.13), o-xylene (0.19), styrene (0.27); propionaldehyde (9.26), butyraldehyde (6.19), isovaleraldehyde (2.14), n-valeraldehyde (3.98), methyl ethyl ketone (10.5), methyl isobutyl ketone (3.93), n-butyl acetate (2.41), and isobutyl alcohol (22.2). PMID:24704185

  7. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-02-17

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self

  8. Air Cherenkov methods in cosmic rays: Review and some history

    NASA Astrophysics Data System (ADS)

    Lidvansky, A. S.

    2006-08-01

    Radiation first discovered by Pavel Cherenkov is used for developing a variety of methods in cosmic-ray studies. Among them, air Cherenkov methods form a separate area with several lines of research. Numerous applications of air Cherenkov radiation in studies of extensive air showers, in γ-astronomy and neutrino physics are reviewed. A tribute is given to Alexander Chudakov whose pioneer ideas and experimental skill laid foundation for the present-day progress.

  9. Comparison of stationary and personal air sampling with an air dispersion model for children's ambient exposure to manganese.

    PubMed

    Fulk, Florence; Haynes, Erin N; Hilbert, Timothy J; Brown, David; Petersen, Dan; Reponen, Tiina

    2016-09-01

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to assess exposure for children enrolled in the Communities Actively Researching Exposure Study in Marietta, OH. Ambient air Mn concentration values were modeled using US Environmental Protection Agency's Air Dispersion Model AERMOD based on emissions from the ferromanganese refinery located in Marietta. Modeled Mn concentrations were compared with Mn concentrations from a nearby stationary air monitor. The Index of Agreement for modeled versus monitored data was 0.34 (48 h levels) and 0.79 (monthly levels). Fractional bias was 0.026 for 48 h levels and -0.019 for monthly levels. The ratio of modeled ambient air Mn to measured ambient air Mn at the annual time scale was 0.94. Modeled values were also time matched to personal air samples for 19 children. The modeled values explained a greater degree of variability in personal exposures compared with time-weighted distance from the emission source. Based on these results modeled Mn concentrations provided a suitable approach for assessing airborne Mn exposure in this cohort. PMID:27168393

  10. Detection of the Urban Release of a Bacillus anthracis Simulant by Air Sampling

    PubMed Central

    Garza, Alexander G.; Van Cuyk, Sheila M.; Brown, Michael J.

    2014-01-01

    In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques. PMID:24697146

  11. Detection of the urban release of a bacillus anthracis simulant by air sampling.

    PubMed

    Garza, Alexander G; Van Cuyk, Sheila M; Brown, Michael J; Omberg, Kristin M

    2014-01-01

    In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques. PMID:24697146

  12. Review of the Physical Science Facility Stack Air Sampling Probe Locations

    SciTech Connect

    Glissmeyer, John A.

    2007-09-30

    This letter report reviews compliance of the current design of the Physical Science Facility (PSF) stack air sampling locations with the ANSI/HPS N13.1-1999 standard. The review was based on performance criteria used for locating air sampling probes, the design documents provided and available information on systems previously tested for compliance with the criteria. Recommendations are presented for ways to bring the design into compliance with the requirements for the sampling probe placement.

  13. ANASORB{reg_sign} 747 - A universal sorbent for air sampling?

    SciTech Connect

    Harper, M.

    1997-12-31

    A sorbent to be used for air sampling must meet certain performance criteria including sample background, capacity, stability, and recovery. Anasorb{sup R} 747 is a proprietary 20/40 mesh beaded active carbon prepared from raw materials with a very low ash content in a process which creates a regular pore structure. The background is very low for both inorganic and organic species, and the surface is more inert and less hydrophilic than coconut charcoal, while capacity is similar. The low catalytic activity of the surface means samples of many reactive compounds remain stable for longer periods. The sorbent is compatible with most solvent systems in use (e.g. carbon disulfide, methylene chloride, methanol, dimethyformamide). Anasorb 747 can be coated with chemicals for efficient adsorption of inorganic gases, which can be analyzed at very low levels because of low background interference. A large number of validated sampling methods use Anasorb 747, including methods from OSHA and NIOSH, corporate industrial hygiene laboratories, various branches of the EPA, and international agencies. These methods refer to around fifty different gases and vapors. Although this sorbent is not compatible with some compounds (e.g. low molecular weight aldehydes) it is quite close to being of universal application.

  14. Artifact free denuder method for sampling of carbonaceous aerosols

    NASA Astrophysics Data System (ADS)

    Mikuška, P.; Vecera, Z.; Broškovicová, A.

    2003-04-01

    Over the past decade, a growing attention has been focused on the carbonaceous aerosols. Although they may account for 30--60% of the total fine aerosol mass, their concentration and formation mechanisms are not well understood, particularly in comparison with major fine particle inorganic species. The deficiency in knowledge of carbonaceous aerosols results from their complexity and because of problems associated with their collection. Conventional sampling techniques of the carbonaceous aerosols, which utilize filters/backup adsorbents suffer from sampling artefacts. Positive artifacts are mainly due to adsorption of gas-phase organic compounds by the filter material or by the already collected particles, whereas negative artifacts arise from the volatilisation of already collected organic compounds from the filter. Furthermore, in the course of the sampling, the composition of the collected organic compounds may be modified by oxidants (O_3, NO_2, PAN, peroxides) that are present in the air passing through the sampler. It is clear that new, artifact free, method for sampling of carbonaceous aerosols is needed. A combination of a diffusion denuder and a filter in series is very promising in this respect. The denuder is expected to collect gaseous oxidants and gas-phase organic compounds from sample air stream prior to collection of aerosol particles on filters, and eliminate thus both positive and negative sampling artifacts for carbonaceous aerosols. This combination is subject of the presentation. Several designs of diffusion denuders (cylindrical, annular, parallel plate, multi-channel) in combination with various types of wall coatings (dry, liquid) were examined. Special attention was given to preservation of the long-term collection efficiency. Different adsorbents (activated charcoal, molecular sieve, porous polymers) and sorbents coated with various chemical reagents (KI, Na_2SO_3, MnO_2, ascorbic acid) or chromatographic stationary phases (silicon oils

  15. Automated air-void system characterization of hardened concrete: Helping computers to count air-voids like people count air-voids---Methods for flatbed scanner calibration

    NASA Astrophysics Data System (ADS)

    Peterson, Karl

    Since the discovery in the late 1930s that air entrainment can improve the durability of concrete, it has been important for people to know the quantity, spacial distribution, and size distribution of the air-voids in their concrete mixes in order to ensure a durable final product. The task of air-void system characterization has fallen on the microscopist, who, according to a standard test method laid forth by the American Society of Testing and Materials, must meticulously count or measure about a thousand air-voids per sample as exposed on a cut and polished cross-section of concrete. The equipment used to perform this task has traditionally included a stereomicroscope, a mechanical stage, and a tally counter. Over the past 30 years, with the availability of computers and digital imaging, automated methods have been introduced to perform the same task, but using the same basic equipment. The method described here replaces the microscope and mechanical stage with an ordinary flatbed desktop scanner, and replaces the microscopist and tally counter with a personal computer; two pieces of equipment much more readily available than a microscope with a mechanical stage, and certainly easier to find than a person willing to sit for extended periods of time counting air-voids. Most laboratories that perform air-void system characterization typically have cabinets full of prepared samples with corresponding results from manual operators. Proponents of automated methods often take advantage of this fact by analyzing the same samples and comparing the results. A similar iterative approach is described here where scanned images collected from a significant number of samples are analyzed, the results compared to those of the manual operator, and the settings optimized to best approximate the results of the manual operator. The results of this calibration procedure are compared to an alternative calibration procedure based on the more rigorous digital image accuracy

  16. Study of PCBs and PBDEs in King George Island, Antarctica, using PUF passive air sampling

    NASA Astrophysics Data System (ADS)

    Li, Yingming; Geng, Dawei; Liu, Fubin; Wang, Thanh; Wang, Pu; Zhang, Qinghua; Jiang, Guibin

    2012-05-01

    Polyurethane foam (PUF)-disk based passive air samplers were deployed in King George Island, Antarctica, during the austral summer of 2009-2010, to investigate levels, distributions and potential sources of polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in Antarctic air. The atmospheric levels of ∑ indicator PCBs and ∑14 PBDEs ranged from 1.66 to 6.50 pg m-3 and from 0.67 to 2.98 pg m-3, respectively. PCBs homologue profiles were dominated by di-PCBs, tri-PCBs and tetra-PCBs, whereas BDE-17 and BDE-28 were the predominant congeners of PBDEs, which could be explained by long-range atmospheric transport processes. However, the sampling sites close to the Antarctic research stations showed higher atmospheric concentrations of PCBs and PBDEs than the other sites, reflecting potential local sources from the Antarctic research stations. The non-Aroclor congener PCB-11 was found in all the air samples, with air concentrations of 3.60-31.4 pg m-3 (average 15.2 pg m-3). Comparison between the results derived from PUF-disk passive air sampling and high-volume air sampling validates the feasibility of using the passive air samplers in Antarctic air. To our knowledge, this study is the first employment of PUF-disk based passive air samplers in Antarctic atmosphere.

  17. Summary of gamma spectrometry on local air samples from 1985--1995

    SciTech Connect

    Winn, W.G.

    1997-04-02

    This report summarizes the 1985--1995 results of low-level HPGe gamma spectrometry analysis of high-volume air samples collected at the Aiken Airport, which is about 25 miles north of SRS. The author began analyzing these samples with new calibrations using the newly developed GRABGAM code in 1985. The air sample collections were terminated in 1995, as the facilities at the Aiken Airport were no longer available. Air sample measurements prior to 1985 were conducted with a different analysis system (and by others prior to 1984), and the data were not readily available. The report serves to closeout this phase of local NTS air sample studies, while documenting the capabilities and accomplishments. Hopefully, the information will guide other applications for this technology, both locally and elsewhere.

  18. Aerostat-lofted instrument and sampling method for determination of emissions from open area sources

    EPA Science Inventory

    An aerostat-borne instrument and sampling method was developed to characterize air samples from area sources, such as emissions from open burning. The 10 kg battery-powered instrument system, termed "the Flyer," is lofted with a helium-filled aerostat of 4 m nominal diameter and ...

  19. System and method for extracting a sample from a surface

    SciTech Connect

    Van Berkel, Gary; Covey, Thomas

    2015-06-23

    A system and method is disclosed for extracting a sample from a sample surface. A sample is provided and a sample surface receives the sample which is deposited on the sample surface. A hydrophobic material is applied to the sample surface, and one or more devices are configured to dispense a liquid on the sample, the liquid dissolving the sample to form a dissolved sample material, and the one or more devices are configured to extract the dissolved sample material from the sample surface.

  20. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-104 at the Conclusion of 7A

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-l04 (7 A) flight to the ISS is reported. ISS air samples were taken in June and July 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Atlantis using GSCs. Solid sorbent air sampler (SSAS) samples were obtained from the ISS in April, June, and July. Analytical methods have not changed from earlier reports, and all quality control measures were met.

  1. Automatic method for inspecting plywood shear samples

    NASA Astrophysics Data System (ADS)

    Avent, R. R., III; Conners, Richard W.

    1991-03-01

    A plywood panel is composed of several layers of wood bonded together by glue. The adhesive integrity of the glue formulation employed must surpass the structural integrity of wood used to make the panel. The American Plywood Association (APA) regularly tests plywood from manufacturing plants to ensure that this performance requirement is met. One of the procedures used is to saw a panel into a number of 1 X 3- 1/4 inch blocks called samples. These samples are then subjected to a number of treatments to simulate natural aging. The treated samples are then sheared into two halves. A 1 X 1 inch area on each of the two halves is then visually inspected to determine the percent wood failure that occurred during the shear. Roughly speaking a region of solid wood or a region of wood fibers embedded in glue is considered to be a region of wood failure while a region of glue is considered to be a region of glue failure. If the percent wood failure of sample from a significant number or panels from a plant is too low, the right to use the APA trademarks is withdrawn. The number of samples inspected annually by the APA is in the millions. The human inspectors are well trained, typically having years of experience, and are regularly tested. As in any human endeavor, the inspectors are subject to fatigue, boredom, etc. For these and other reasons an automatic inspection system could aid the APA in better performing its regulatory role.

  2. Estimation of sampling error uncertainties in observed surface air temperature change in China

    NASA Astrophysics Data System (ADS)

    Hua, Wei; Shen, Samuel S. P.; Weithmann, Alexander; Wang, Huijun

    2016-06-01

    This study examines the sampling error uncertainties in the monthly surface air temperature (SAT) change in China over recent decades, focusing on the uncertainties of gridded data, national averages, and linear trends. Results indicate that large sampling error variances appear at the station-sparse area of northern and western China with the maximum value exceeding 2.0 K2 while small sampling error variances are found at the station-dense area of southern and eastern China with most grid values being less than 0.05 K2. In general, the negative temperature existed in each month prior to the 1980s, and a warming in temperature began thereafter, which accelerated in the early and mid-1990s. The increasing trend in the SAT series was observed for each month of the year with the largest temperature increase and highest uncertainty of 0.51 ± 0.29 K (10 year)-1 occurring in February and the weakest trend and smallest uncertainty of 0.13 ± 0.07 K (10 year)-1 in August. The sampling error uncertainties in the national average annual mean SAT series are not sufficiently large to alter the conclusion of the persistent warming in China. In addition, the sampling error uncertainties in the SAT series show a clear variation compared with other uncertainty estimation methods, which is a plausible reason for the inconsistent variations between our estimate and other studies during this period.

  3. COAL SAMPLING AND ANALYSIS: METHODS AND MODELS

    EPA Science Inventory

    The report provides information on coal sampling and analysis (CSD) techniques and procedures and presents a statistical model for estimating SO2 emissions. (New Source Performance Standards for large coal-fired boilers and certain State Implementation Plans require operators to ...

  4. Topics in Research Methods: Survey Sampling.

    ERIC Educational Resources Information Center

    Cook, Tony; Rushton, Brian S.

    1984-01-01

    Reviews a computer-assisted learning package (available from CONDUIT) which introduces survey and sampling techniques by pretending that the user is a pollster asking one of six questions of a more or less political nature. Documentation and performance are rated fair while ease of use is considered excellent. (JN)

  5. Measuring Book Availability: A Monthly Sampling Method.

    ERIC Educational Resources Information Center

    Norton, Mick; And Others

    1996-01-01

    Demonstrates that by using barcodes to identify random lists of books, taking small monthly samples, and updating a simple control chart, one can effectively: (1) pinpoint reasons why library books are unavailable; (2) gauge if corrective actions or changes in procedure are needed; and (3) determine if such actions are successful. Contains two…

  6. Dispersion modeling of selected PAHs in urban air: A new approach combining dispersion model with GIS and passive air sampling

    NASA Astrophysics Data System (ADS)

    Sáňka, Ondřej; Melymuk, Lisa; Čupr, Pavel; Dvorská, Alice; Klánová, Jana

    2014-10-01

    This study introduces a new combined air concentration measurement and modeling approach that we propose can be useful in medium and long term air quality assessment. A dispersion study was carried out for four high molecular weight polycyclic aromatic hydrocarbons (PAHs) in an urban area with industrial, traffic and domestic heating sources. A geographic information system (GIS) was used both for processing of input data as well as visualization of the modeling results. The outcomes of the dispersion model were compared to the results of passive air sampling (PAS). Despite discrepancies between measured and modeled concentrations, an approach combining the two techniques is promising for future air quality assessment. Differences between measured and modeled concentrations, in particular when measured values exceed the modeled concentrations, are indicative of undocumented, sporadic pollutant sources. Thus, these differences can also be useful for assessing and refining emission inventories.

  7. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Service, Dairy Programs, or Official Methods of Analysis of the Association of Analytical Chemists or... 7 Agriculture 3 2011-01-01 2011-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods...

  8. Sampling, storage, and analysis of C2-C7 non-methane hydrocarbons from the US National Oceanic and Atmospheric Administration Cooperative Air Sampling Network glass flasks.

    PubMed

    Pollmann, Jan; Helmig, Detlev; Hueber, Jacques; Plass-Dülmer, Christian; Tans, Pieter

    2008-04-25

    An analytical technique was developed to analyze light non-methane hydrocarbons (NMHC), including ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane, n-hexane, isoprene, benzene and toluene from whole air samples collected in 2.5l-glass flasks used by the National Oceanic and Atmospheric Administration, Earth System Research Laboratory, Global Monitoring Division (NOAA ESRL GMD, Boulder, CO, USA) Cooperative Air Sampling Network. This method relies on utilizing the remaining air in these flasks (which is at below-ambient pressure at this stage) after the completion of all routine greenhouse gas measurements from these samples. NMHC in sample aliquots extracted from the flasks were preconcentrated with a custom-made, cryogen-free inlet system and analyzed by gas chromatography (GC) with flame ionization detection (FID). C2-C7 NMHC, depending on their ambient air mixing ratios, could be measured with accuracy and repeatability errors of generally < or =10-20%. Larger deviations were found for ethene and propene. Hexane was systematically overestimated due to a chromatographic co-elution problem. Saturated NMHC showed less than 5% changes in their mixing ratios in glass flask samples that were stored for up to 1 year. In the same experiment ethene and propene increased at approximately 30% yr(-1). A series of blank experiments showed negligible contamination from the sampling process and from storage (<10 pptv yr(-1)) of samples in these glass flasks. Results from flask NMHC analyses were compared to in-situ NMHC measurements at the Global Atmospheric Watch station in Hohenpeissenberg, Germany. This 9-months side-by-side comparison showed good agreement between both methods. More than 94% of all data comparisons for C2-C5 alkanes, isoprene, benzene and toluene fell within the combined accuracy and precision objectives of the World Meteorological Organization Global Atmosphere Watch (WMO-GAW) for NMHC measurements. PMID:18355832

  9. Automated syringe sampler. [remote sampling of air and water

    NASA Technical Reports Server (NTRS)

    Purgold, G. C. (Inventor)

    1981-01-01

    A number of sampling services are disposed in a rack which slides into a housing. In response to a signal from an antenna, the circutry elements are activated which provide power individually, collectively, or selectively to a servomechanism thereby moving an actuator arm and the attached jawed bracket supporting an evaculated tube towards a stationary needle. One open end of the needle extends through the side wall of a conduit to the interior and the other open end is maintained within the protective sleeve, supported by a bifurcated bracket. A septum in punctured by the end of the needle within the sleeve and a sample of the fluid medium in the conduit flows through the needle and is transferred to a tube. The signal to the servo is then reversed and the actuator arm moves the tube back to its original position permitting the septum to expand and seal the hole made by the needle. The jawed bracket is attached by pivot to the actuator to facilitate tube replacement.

  10. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    SciTech Connect

    Langton, C. A.; Almond, P. M.

    2013-11-26

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO{sub 4}{sup -} in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O{sub 4}{sup -}, which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The

  11. Salmonella recovery following air chilling for matched neck-skin and whole carcass sampling methodologies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The prevalence and serogroups of Salmonella recovered following air chilling were determined for both enriched neck skin and matching enriched whole carcass samples. Commercially processed and eviscerated carcasses were air chilled to 4C before removing the neck skin (8.3 g) and stomaching in 83 mL...

  12. Trapping Efficiency of 1,3-Dichloropropene Isomers by XAD-4 Sorbent Tubes for Air Sampling

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Emission monitoring is necessary to evaluate the impact of air pollutants such as soil fumigants on the environment. Quantifying fumigant emissions often involves the use of air sampling tubes filled with sorbents to trap fumigants. 1,3-dichloropropene (1,3-D) and chloropicrin (CP) are being increas...

  13. FIELD EVALUATION OF SAMPLING AND ANALYSIS FOR ORGANIC POLLUTANTS IN INDOOR AIR

    EPA Science Inventory

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, a...

  14. Solvent Selection for Pressurized Liquid Extraction of Polymeric Sorbents Used in Air Sampling

    PubMed Central

    Primbs, Toby; Genualdi, Susan; Simonich, Staci

    2014-01-01

    Pressurized liquid extraction (PLE) was evaluated as a method for extracting semivolatile organic compounds (SOCs) from air sampling media; including quartz fiber filter (QFF), polyurethane foam (PUF), and a polystyrene divinyl benzene copolymer (XAD-2). Hansen solubility parameter plots were used to aid in the PLE solvent selection in order to reduce both co-extraction of polyurethane and save time in evaluating solvent compatibility during the initial steps of method development. A PLE solvent composition of 75:25% hexane:acetone was chosen for PUF. The XAD-2 copolymer was not solubilized under the PLE conditions used. The average percent PLE recoveries (and percent relative standard deviations) of 63 SOCs, including polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and organochlorine, amide, triazine, thiocarbamate, and phosphorothioate pesticides, were 76.7 (6.2), 79.3 (8.1), and 93.4 (2.9) % for the QFF, PUF, and XAD-2, respectively. PMID:18220448

  15. METHODS FOR SAMPLING AND ANALYSIS OF BREATH

    EPA Science Inventory

    The research program surveyed and evaluated the methods and procedures used to identify and quantitate chemical constituents in human breath. Methods have been evaluated to determine their ease and rapidity, as well as cost, accuracy, and precision. During the evaluation, a secon...

  16. Operational air sampling report. [Semiannual report], July 1--December 31, 1993

    SciTech Connect

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products.

  17. Operational air sampling report. [Semiannual report], January 1--June 30, 1993

    SciTech Connect

    Lyons, C.L.

    1993-12-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. This report discusses the REECo air sampling program which is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 243 air samples collected in the only active tunnel complex, none showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 246 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products.

  18. EVALUATION OF SAMPLING AND ANALYTICAL METHODOLOGY FOR POLYNUCLEAR AROMATIC COMPOUNDS IN INDOOR AIR

    EPA Science Inventory

    The objective of this project was to develop a generic sampling and analytical methodology to characterize the polynuclear aromatic hydrocarbon (PAH) concentrations in air within various microenvironments. The following three studies were performed: evaluation of analytical metho...

  19. TECHNOLOGY EVALUATION REPORT CEREX ENVIRONMENTAL SERVICES UV HOUND POINT SAMPLE AIR MONITOR

    EPA Science Inventory

    The USEPA's National Homeland Security Research Center (NHSRC) Technology Testing and Evaluation Program (TTEP) is carrying out performance tests on homeland security technologies. Under TTEP, Battelle evaluated the performance of the Cerex UV Hound point sample air monitor in de...

  20. NEW APPLICATION OF PASSIVE SAMPLING DEVICES FOR ASSESSMENT OF RESPIRATORY EXPOSURE TO PESTICIDES IN INDOOR AIR

    EPA Science Inventory

    The United States Environmental Protection Agency (EPA) has long maintained an interest in potential applications of passive sampling devices (PSDs) for estimating the concentrations of various pollutants in air. Typically PSDs were designed for the workplace monitoring of vola...

  1. Comparison of stationary and personal air sampling with an air dispersion model for children’s ambient exposure to manganese

    EPA Science Inventory

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to asse...

  2. Optimal Media for Use in Air Sampling To Detect Cultivable Bacteria and Fungi in the Pharmacy

    PubMed Central

    Joseph, Riya Augustin; Le, Theresa V.; Trevino, Ernest A.; Schaeffer, M. Frances; Vance, Paula H.

    2013-01-01

    Current guidelines for air sampling for bacteria and fungi in compounding pharmacies require the use of a medium for each type of organism. U.S. Pharmacopeia (USP) chapter <797> (http://www.pbm.va.gov/linksotherresources/docs/USP797PharmaceuticalCompoundingSterileCompounding.pdf) calls for tryptic soy agar with polysorbate and lecithin (TSApl) for bacteria and malt extract agar (MEA) for fungi. In contrast, the Controlled Environment Testing Association (CETA), the professional organization for individuals who certify hoods and clean rooms, states in its 2012 certification application guide (http://www.cetainternational.org/reference/CAG-009v3.pdf?sid=1267) that a single-plate method is acceptable, implying that it is not always necessary to use an additional medium specifically for fungi. In this study, we reviewed 5.5 years of data from our laboratory to determine the utility of TSApl versus yeast malt extract agar (YMEA) for the isolation of fungi. Our findings, from 2,073 air samples obtained from compounding pharmacies, demonstrated that the YMEA yielded >2.5 times more fungal isolates than TSApl. PMID:23903551

  3. Optimal media for use in air sampling to detect cultivable bacteria and fungi in the pharmacy.

    PubMed

    Weissfeld, Alice S; Joseph, Riya Augustin; Le, Theresa V; Trevino, Ernest A; Schaeffer, M Frances; Vance, Paula H

    2013-10-01

    Current guidelines for air sampling for bacteria and fungi in compounding pharmacies require the use of a medium for each type of organism. U.S. Pharmacopeia (USP) chapter <797> (http://www.pbm.va.gov/linksotherresources/docs/USP797PharmaceuticalCompoundingSterileCompounding.pdf) calls for tryptic soy agar with polysorbate and lecithin (TSApl) for bacteria and malt extract agar (MEA) for fungi. In contrast, the Controlled Environment Testing Association (CETA), the professional organization for individuals who certify hoods and clean rooms, states in its 2012 certification application guide (http://www.cetainternational.org/reference/CAG-009v3.pdf?sid=1267) that a single-plate method is acceptable, implying that it is not always necessary to use an additional medium specifically for fungi. In this study, we reviewed 5.5 years of data from our laboratory to determine the utility of TSApl versus yeast malt extract agar (YMEA) for the isolation of fungi. Our findings, from 2,073 air samples obtained from compounding pharmacies, demonstrated that the YMEA yielded >2.5 times more fungal isolates than TSApl. PMID:23903551

  4. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration. PMID:21793731

  5. AMBIENT MEASUREMENT METHODS AND PROPERTIES OF THE 189 CLEAN AIR ACT HAZARDOUS AIR POLLUTANTS

    EPA Science Inventory

    Measurement methods for the 189 Hazardous Air Pollutants (HAPS) designated in Title III of the 1990 Clean Air Act Amendments are either identified or suggested for all but 10 of the compounds. n extensive list of chemical and physical properties are developed for all compounds. u...

  6. Fast detection of air contaminants using immunobiological methods

    NASA Astrophysics Data System (ADS)

    Schmitt, Katrin; Bolwien, Carsten; Sulz, Gerd; Koch, Wolfgang; Dunkhorst, Wilhelm; Lödding, Hubert; Schwarz, Katharina; Holländer, Andreas; Klockenbring, Torsten; Barth, Stefan; Seidel, Björn; Hofbauer, Wolfgang; Rennebarth, Torsten; Renzl, Anna

    2009-05-01

    The fast and direct identification of possibly pathogenic microorganisms in air is gaining increasing interest due to their threat for public health, e.g. in clinical environments or in clean rooms of food or pharmaceutical industries. We present a new detection method allowing the direct recognition of relevant germs or bacteria via fluorescence-labeled antibodies within less than one hour. In detail, an air-sampling unit passes particles in the relevant size range to a substrate which contains antibodies with fluorescence labels for the detection of a specific microorganism. After the removal of the excess antibodies the optical detection unit comprising reflected-light and epifluorescence microscopy can identify the microorganisms by fast image processing on a single-particle level. First measurements with the system to identify various test particles as well as interfering influences have been performed, in particular with respect to autofluorescence of dust particles. Specific antibodies for the detection of Aspergillus fumigatus spores have been established. The biological test system consists of protein A-coated polymer particles which are detected by a fluorescence-labeled IgG. Furthermore the influence of interfering particles such as dust or debris is discussed.

  7. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling by Customs. 151.70 Section 151.70 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... Method of sampling by Customs. A general sample shall be taken from each sampling unit, unless it is...

  8. A Comparison of EPI Sampling, Probability Sampling, and Compact Segment Sampling Methods for Micro and Small Enterprises

    PubMed Central

    Chao, Li-Wei; Szrek, Helena; Peltzer, Karl; Ramlagan, Shandir; Fleming, Peter; Leite, Rui; Magerman, Jesswill; Ngwenya, Godfrey B.; Pereira, Nuno Sousa; Behrman, Jere

    2011-01-01

    Finding an efficient method for sampling micro- and small-enterprises (MSEs) for research and statistical reporting purposes is a challenge in developing countries, where registries of MSEs are often nonexistent or outdated. This lack of a sampling frame creates an obstacle in finding a representative sample of MSEs. This study uses computer simulations to draw samples from a census of businesses and non-businesses in the Tshwane Municipality of South Africa, using three different sampling methods: the traditional probability sampling method, the compact segment sampling method, and the World Health Organization’s Expanded Programme on Immunization (EPI) sampling method. Three mechanisms by which the methods could differ are tested, the proximity selection of respondents, the at-home selection of respondents, and the use of inaccurate probability weights. The results highlight the importance of revisits and accurate probability weights, but the lesser effect of proximity selection on the samples’ statistical properties. PMID:22582004

  9. Potassium bromide method of infrared sampling

    USGS Publications Warehouse

    Milkey, R.G.

    1958-01-01

    In the preparation of potassium bromide pressed windows for use in the infrared analysis of solids, severe grinding of the potassium bromide powder may produce strong absorption bands that could interfere seriously with the spectra of the sample. These absorption bands appear to be due to some crystal alteration of the potassium bromide as a result of the grinding process. They were less apt to occur when the coarser powder, which had received a relatively gentle grinding, was used. Window blanks prepared from the coarser powders showed smaller adsorbed water peaks and generally higher over-all transmittance readings than windows pressed from the very fine powders.

  10. Modified electrokinetic sample injection method in chromatography and electrophoresis analysis

    DOEpatents

    Davidson, J. Courtney; Balch, Joseph W.

    2001-01-01

    A sample injection method for horizontal configured multiple chromatography or electrophoresis units, each containing a number of separation/analysis channels, that enables efficient introduction of analyte samples. This method for loading when taken in conjunction with horizontal microchannels allows much reduced sample volumes and a means of sample stacking to greatly reduce the concentration of the sample. This reduction in the amount of sample can lead to great cost savings in sample preparation, particularly in massively parallel applications such as DNA sequencing. The essence of this method is in preparation of the input of the separation channel, the physical sample introduction, and subsequent removal of excess material. By this method, sample volumes of 100 nanoliter to 2 microliters have been used successfully, compared to the typical 5 microliters of sample required by the prior separation/analysis method.

  11. A method for sampling waste corn

    USGS Publications Warehouse

    Frederick, R.B.; Klaas, E.E.; Baldassarre, G.A.; Reinecke, K.J.

    1984-01-01

    Corn had become one of the most important wildlife food in the United States. It is eaten by a wide variety of animals, including white-tailed deer (Odocoileus virginianus ), raccoon (Procyon lotor ), ring-necked pheasant (Phasianus colchicus , wild turkey (Meleagris gallopavo ), and many species of aquatic birds. Damage to unharvested crops had been documented, but many birds and mammals eat waste grain after harvest and do not conflict with agriculture. A good method for measuring waste-corn availability can be essential to studies concerning food density and food and feeding habits of field-feeding wildlife. Previous methods were developed primarily for approximating losses due to harvest machinery. In this paper, a method is described for estimating the amount of waste corn potentially available to wildlife. Detection of temporal changes in food availability and differences caused by agricultural operations (e.g., recently harvested stubble fields vs. plowed fields) are discussed.

  12. Evaluation of Sampling Methods and Development of Sample Plans for Estimating Predator Densities in Cotton

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The cost-reliability of five sampling methods (visual search, drop cloth, beat bucket, shake bucket and sweep net) was determined for predatory arthropods on cotton plants. The beat bucket sample method was the most cost-reliable while the visual sample method was the least cost-reliable. The beat ...

  13. Surface sampling methods for Bacillus anthracis spore contamination.

    PubMed

    Sanderson, Wayne T; Hein, Misty J; Taylor, Lauralynn; Curwin, Brian D; Kinnes, Gregory M; Seitz, Teresa A; Popovic, Tanja; Holmes, Harvey T; Kellum, Molly E; McAllister, Sigrid K; Whaley, David N; Tupin, Edward A; Walker, Timothy; Freed, Jennifer A; Small, Dorothy S; Klusaritz, Brian; Bridges, John H

    2002-10-01

    During an investigation conducted December 17-20, 2001, we collected environmental samples from a U.S. postal facility in Washington, D.C., known to be extensively contaminated with Bacillus anthracis spores. Because methods for collecting and analyzing B. anthracis spores have not yet been validated, our objective was to compare the relative effectiveness of sampling methods used for collecting spores from contaminated surfaces. Comparison of wipe, wet and dry swab, and HEPA vacuum sock samples on nonporous surfaces indicated good agreement between results with HEPA vacuum and wipe samples. However, results from HEPA vacuum sock and wipe samples agreed poorly with the swab samples. Dry swabs failed to detect spores >75% of the time when they were detected by wipe and HEPA vacuum samples. Wipe samples collected after HEPA vacuum samples and HEPA vacuum samples collected after wipe samples indicated that neither method completely removed spores from the sampled surfaces. PMID:12396930

  14. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL, as issued by the USDA,...

  15. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL as issued by the USDA, Agricultural...

  16. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Marketing Service, Dairy Programs, or the Official Methods of Analysis of the Association of Official... 7 Agriculture 3 2011-01-01 2011-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable...

  17. Air Pollution Instrumentation: A Trend toward Physical Methods

    ERIC Educational Resources Information Center

    Maugh, Thomas H., II

    1972-01-01

    Reviews reasons for the trend from wet chemical'' analytic techniques for measuring air pollutants toward physical methods based upon chemiluminescence, electrochemical transduction, flame ionization coupled with gas chromotography, and spectroscopy. (AL)

  18. IMPROVEMENT IN AIR TOXICS METHODS FOR VOLATILE ORGANIC COMPOUNDS

    EPA Science Inventory

    Innovative and customized monitoring methods for air toxic volatile organic compounds (VOCs) are being developed for applications in exposure and trends monitoring. This task addresses the following applications of specific interest:

    o Contributions to EPA Regional Monit...

  19. Ground-based air-sampling measurements near the Nevada Test Site after atmospheric nuclear tests.

    PubMed

    Cederwall, R T; Ricker, Y E; Cederwall, P L; Homan, D N; Anspaugh, L R

    1990-11-01

    Historical air-sampling data measured within 320 km (200 mi) of the Nevada Test Site (NTS) have been reviewed for periods following atmospheric nuclear tests, primarily in the 1950s. These data come mostly from high-volume air samplers, with some from cascade-impactor samplers. Measurements considered here are for beta radiation from gross fission products. The resulting air-quality data base is comprised of almost 13,000 samples from 42 sampling locations downwind of the NTS. In order to compile an accurate air-quality data base for use in estimating exposure via inhalation, raw data values were sought where possible, and the required calculations were performed on a computer with state-of-the-art algorithms. The data-processing procedures consisted of (1) entry and error checking of historical data; (2) determination of appropriate background values, air-sampling volumes, and net air concentrations; and (3) calculation of integrated air concentration (C) for each sample (considering fallout arrival times). Comparing C values for collocated high-volume and cascade-impactor samplers during the Upshot-Knothole series showed similar lognormal distributions, but with a geometric mean C for cascade impactors about half that for the high-volume air samplers. Overall, the uncertainty in C values is about a factor of three. In the past, it has been assumed that C could be related to ground deposition by a constant having units of velocity. In our data bases, simultaneous measurements of air concentration and ground deposition at the same locations were not related by a constant; indeed, there was a great amount of scatter. This suggests that the relationship between C and ground deposition in this situation is too complex to be treated adequately by simple approaches. PMID:2211113

  20. Ground-based air-sampling measurements near the Nevada Test Site after atmospheric nuclear tests

    SciTech Connect

    Cederwall, R.T.; Ricker, Y.E.; Cederwall, P.L.; Homan, D.N.; Anspaugh, L.R. )

    1990-11-01

    Historical air-sampling data measured within 320 km (200 mi) of the Nevada Test Site (NTS) have been reviewed for periods following atmospheric nuclear tests, primarily in the 1950s. These data come mostly from high-volume air samplers, with some from cascade-impactor samplers. Measurements considered here are for beta radiation from gross fission products. The resulting air-quality data base is comprised of almost 13,000 samples from 42 sampling locations downwind of the NTS. In order to compile an accurate air-quality data base for use in estimating exposure via inhalation, raw data values were sought where possible, and the required calculations were performed on a computer with state-of-the-art algorithms. The data-processing procedures consisted of (1) entry and error checking of historical data; (2) determination of appropriate background values, air-sampling volumes, and net air concentrations; and (3) calculation of integrated air concentration (C) for each sample (considering fallout arrival times). Comparing C values for collocated high-volume and cascade-impactor samplers during the Upshot-Knothole series showed similar lognormal distributions, but with a geometric mean C for cascade impactors about half that for the high-volume air samplers. Overall, the uncertainty in C values is about a factor of three. In the past, it has been assumed that C could be related to ground deposition by a constant having units of velocity. In our data bases, simultaneous measurements of air concentration and ground deposition at the same locations were not related by a constant; indeed, there was a great amount of scatter. This suggests that the relationship between C and ground deposition in this situation is too complex to be treated adequately by simple approaches.

  1. Evaluation of sampling and analytical methodology for polynuclear aromatic compounds in indoor air. Final report, 1 March-30 September 1985

    SciTech Connect

    Chuang, C.C.; Mack, G.A.; Mondron, P.J.; Petersen, B.A.

    1985-10-01

    The objective of this project was to develop a generic sampling and analytical methodology to characterize the polynuclear aromatic hydrocarbon (PAH) concentrations in air within various microenvironments. The following three studies were performed: evaluation of analytical methods, design of a sampling method, and design of a pilot study. Two analytical methods, high performance liquid chromatography with ultraviolet adsorption and fluorescence detection and gas chromatography/mass spectrometry, were evaluated for the determination of PAHs and their derivatives in air within microenvironments. The results showed that gas chromatography/positive chemical ionization massspectrometry with data acquisition in the selected ion-monitoring mode is the preferred analytical approach. A modified EPA high-volume sampler, consisting of a quartz fiber filter and a polyurethane foam cartridge, is proposed for use in a future experimental study. A literature review was conducted to determine what is known about the contribution of cigarette smoke to the levels of PAHs in air within microenvironments and to evaluate the use of quinoline and isoquinoline as possible marker compounds for the levels of cigarette smoke. A pilot study was designed to assess PAH levels in air found in residences. A study using this design, was conducted in Columbus, Ohio, during the winter of 1983/84. These results can then be applied to a future large-scale study involving the measurement of human exposure to PAH in air.

  2. Method and Apparatus for Measuring Surface Air Pressure

    NASA Technical Reports Server (NTRS)

    Lin, Bing (Inventor); Hu, Yongxiang (Inventor)

    2014-01-01

    The present invention is directed to an apparatus and method for remotely measuring surface air pressure. In one embodiment, the method of the present invention utilizes the steps of transmitting a signal having multiple frequencies into the atmosphere, measuring the transmitted/reflected signal to determine the relative received power level of each frequency and then determining the surface air pressure based upon the attenuation of the transmitted frequencies.

  3. Microfluidic DNA sample preparation method and device

    DOEpatents

    Krulevitch, Peter A.; Miles, Robin R.; Wang, Xiao-Bo; Mariella, Raymond P.; Gascoyne, Peter R. C.; Balch, Joseph W.

    2002-01-01

    Manipulation of DNA molecules in solution has become an essential aspect of genetic analyses used for biomedical assays, the identification of hazardous bacterial agents, and in decoding the human genome. Currently, most of the steps involved in preparing a DNA sample for analysis are performed manually and are time, labor, and equipment intensive. These steps include extraction of the DNA from spores or cells, separation of the DNA from other particles and molecules in the solution (e.g. dust, smoke, cell/spore debris, and proteins), and separation of the DNA itself into strands of specific lengths. Dielectrophoresis (DEP), a phenomenon whereby polarizable particles move in response to a gradient in electric field, can be used to manipulate and separate DNA in an automated fashion, considerably reducing the time and expense involved in DNA analyses, as well as allowing for the miniaturization of DNA analysis instruments. These applications include direct transport of DNA, trapping of DNA to allow for its separation from other particles or molecules in the solution, and the separation of DNA into strands of varying lengths.

  4. Determination of reduced sulfur compounds in air samples for the monitoring of malodor caused by landfills.

    PubMed

    Borrás, Esther; Tortajada-Genaro, Luis Antonio; Muñoz, Amalia

    2016-02-01

    A reliable method for determining malodorous reduced sulfur compounds (RSC) in atmospheric samples has been developed. The method uses an activated coconut solid-phase sorbent for active sampling, hexane as desorption solvent, and gas chromatography-mass spectrometry (GC-MS) technique for specific and sensitive separation-detection. The compounds analyzed were hydrogen sulfide, ethyl mercaptan, dimethyl sulfide, carbon disulfide, butyl mercaptan and dimethyl disulfide. Recovery efficiency varied between 75% and 97% and no detectable losses were observed during storage at -20°C. Satisfactory analytical parameters were reported, such as good linearity (r(2)>0.98), low detection limits (0.6-59 pg m(-3)), adequate repeatability (9%) and reproducibility (17%), and fast GC-MS analysis (<6.5 min). The accurate determination of RSCs, free of interferences from atmospheric components, such as ozone or water was demonstrated. The method has been applied to analyze the composition of environmental air close to three landfills processing urban and industrial solid wastes. The results indicated that hydrogen sulfide and ethyl mercaptan were the main molecules responsible of malodor phenomenon in the study areas. PMID:26653474

  5. Microbial counts and particulate matter levels in roadside air samples under skytrain stations, Bangkok, Thailand.

    PubMed

    Luksamijarulkul, Pipat; Kongtip, Pornpimol

    2010-05-01

    In conditions with heavy traffic and crowds of people on roadside areas under skytrain stations in Bangkok, the natural air ventilation may be insufficient and air quality may be poor. A study of 350 air samples collected from the roadside, under skytrain stations in Bangkok, was carried out to assess microbial counts (210 air samples) and particulate matter (PM10) levels (140 samples). The results reveal the mean +/- standard deviation bacterial counts and fungal counts were 406.8 +/- 302.7 cfu/m3 and 128.9 +/- 89.7 cfu/m3, respectively. The PM10 level was 186.1 +/- 188.1 microg/m3. When compared to recommended levels, 4.8% of air samples (10/210 samples) had bacterial counts more than recommended levels (> 1,000 cfu/ m3) and 27.1% (38/140 samples) had PM10 levels more than recommended levels (> 120 microg/m3). These may affect human health, especially of street venders who spend most of their working time in these areas. PMID:20578558

  6. Methods for characterizing, classifying, and identifying unknowns in samples

    DOEpatents

    Grate, Jay W.; Wise, Barry M.

    2003-08-12

    Disclosed is a method for taking the data generated from an array of responses from a multichannel instrument, and determining the characteristics of a chemical in the sample without the necessity of calibrating or training the instrument with known samples containing the same chemical. The characteristics determined by the method are then used to classify and identify the chemical in the sample. The method can also be used to quantify the concentration of the chemical in the sample.

  7. Methods for characterizing, classifying, and identifying unknowns in samples

    DOEpatents

    Grate, Jay W [West Richland, WA; Wise, Barry M [Manson, WA

    2002-01-01

    Disclosed is a method for taking the data generated from an array of responses from a multichannel instrument, and determining the characteristics of a chemical in the sample without the necessity of calibrating or training the instrument with known samples containing the same chemical. The characteristics determined by the method are then used to classify and identify the chemical in the sample. The method can also be used to quantify the concentration of the chemical in the sample.

  8. IMPROVED TEST METHODS FOR ELECTRONIC AIR CLEANERS

    EPA Science Inventory

    The objective of this project was to develop a fractional filtration efficiency test protocol for residential electrostatic precipitators (ESPs) that avoids the limitations of the ASHRAE 52.2 method. Specifically, the objectives were to a) determine the change in efficiency that ...

  9. Development of a multicopter-carried whole air sampling apparatus and its applications in environmental studies.

    PubMed

    Chang, Chih-Chung; Wang, Jia-Lin; Chang, Chih-Yuan; Liang, Mao-Chang; Lin, Ming-Ren

    2016-02-01

    To advance the capabilities of probing chemical composition aloft, we designed a lightweight remote-controlled whole air sampling component (WASC) and integrated it into a multicopter drone with agile maneuverability to perform aerial whole air sampling. A field mission hovering over an exhaust shaft of a roadway tunnel to collect air samples was performed to demonstrate the applicability of the multicopter-carried WASC apparatus. Ten aerial air samples surrounding the shaft vent were collected by the multicopter-carried WASC. Additional five samples were collected manually inside the shaft for comparison. These samples were then analyzed in the laboratory for the chemical composition of 109 volatile organic compounds (VOCs), CH4, CO, CO2, or CO2 isotopologues. Most of the VOCs in the upwind samples (the least affected by shaft exhaust) were low in concentrations (5.9 ppbv for total 109 VOCs), posting a strong contrast to those in the shaft exhaust (235.8 ppbv for total 109 VOCs). By comparing the aerial samples with the in-shaft samples for chemical compositions, the influence of the shaft exhaust on the surrounding natural air was estimated. Through the aerial measurements, three major advantages of the multicopter-carried WASC were demonstrated: 1. The highly maneuverable multicopter-carried WASC can be readily deployed for three-dimensional environmental studies at a local scale (0-1.5 km); 2. Aerial sampling with superior sample integrity and preservation conditions can now be performed with ease; and 3. Data with spatial resolution for a large array of gaseous species with high precision can be easily obtained. PMID:26386435

  10. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved sampling devices; operation; air flowrate. 90.205 Section 90.205 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures §...

  11. DEVELOPMENT OF A SUB-SLAB AIR SAMPLING PROTOCOL TO SUPPORT ASSESSMENT OF VAPOR INTRUSION

    EPA Science Inventory

    The primary purpose of this research effort is to develop a methodology for sub-slab sampling to support the EPA guidance and vapor intrusion investigations after vapor intrusion has been established at a site. Methodologies for sub-slab air sampling are currently lacking in ref...

  12. Report on sampling and analysis of ambient air at the central waste complex

    SciTech Connect

    Stauffer, M., Fluor Daniel Hanford

    1997-02-13

    Over 160 ambient indoor air samples were collected from warehouses at the Central Waste Complex used for the storage of low- level radioactive and mixed wastes. These grab (SUMMA) samples were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data from this survey suggest that several buildings had elevated concentrations of volatile organic compounds.

  13. EVALUATION OF THE FILTER PACK FOR LONG-DURATION SAMPLING OF AMBIENT AIR

    EPA Science Inventory

    A 14-week filter pack (FP) sampler evaluation field study was conducted at a site near Bondville, IL to investigate the impact of weekly sampling duration. Simultaneous samples were collected using collocated filter packs (FP) from two independent air quality monitoring networks...

  14. Technique for determination of accurate heat capacities of volatile, powdered, or air-sensitive samples using relaxation calorimetry

    NASA Astrophysics Data System (ADS)

    Marriott, Robert A.; Stancescu, Maria; Kennedy, Catherine A.; White, Mary Anne

    2006-09-01

    We introduce a four-step technique for the accurate determination of the heat capacity of volatile or air-sensitive samples using relaxation calorimetry. The samples are encapsulated in a hermetically sealed differential scanning calorimetry pan, in which there is an internal layer of Apiezon N grease to assist thermal relaxation. Using the Quantum Design physical property measurement system to investigate benzoic acid and copper standards, we find that this method can lead to heat capacity determinations accurate to ±2% over the temperature range of 1-300K, even for very small samples (e.g., <10mg and contributing ca. 20% to the total heat capacity).

  15. Field sampling method for quantifying odorants in humid environments.

    PubMed

    Trabue, Steven L; Scoggin, Kenwood D; Li, Hong; Burns, Robert; Xin, Hongwei

    2008-05-15

    Most air quality studies in agricultural environments use thermal desorption analysis for quantifying semivolatile organic compounds (SVOCs) associated with odor. The objective of this study was to develop a robust sampling technique for measuring SVOCs in humid environments. Test atmospheres were generated at ambient temperatures (23 +/- 1.5 degrees C) and 25, 50, and 80% relative humidity (RH). Sorbent material used included Tenax, graphitized carbon, and carbon molecular sieve (CMS). Sorbent tubes were challenged with 2, 4, 8, 12, and 24 L of air at various RHs. Sorbent tubes with CMS material performed poorly at both 50 and 80% RH dueto excessive sorption of water. Heating of CMS tubes during sampling or dry-purging of CMS tubes post sampling effectively reduced water sorption with heating of tubes being preferred due to the higher recovery and reproducibility. Tenaxtubes had breakthrough of the more volatile compounds and tended to form artifacts with increasing volumes of air sampled. Graphitized carbon sorbent tubes containing Carbopack X and Carbopack C performed best with quantitative recovery of all compounds at all RHs and sampling volumes tested. The graphitized carbon tubes were taken to the field for further testing. Field samples taken from inside swine feeding operations showed that butanoic acid, 4-methylphenol, 4-ethylphenol, indole, and 3-methylindole were the compounds detected most often above their odor threshold values. Field samples taken from a poultry facility demonstrated that butanoic acid, 3-methylbutanoic acid, and 4-methylphenol were the compounds above their odor threshold values detected most often, relative humidity, CAFO, VOC, SVOC, thermal desorption, swine, poultry, air quality, odor. PMID:18546717

  16. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  17. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  18. 19 CFR 151.83 - Method of sampling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling. For determining the staple length of any lot...

  19. ELECTROSTATIC AIR CLEANING DEVICE AND METHOD

    DOEpatents

    Silverman, L.; Anderson, D.M.

    1961-07-18

    A method and apparatus for utilizing friction-charged particulate material from an aerosol are described. A bed of the plastic spheres is prepared, and the aerosol is passed upwardly through the bed at a rate just large enough to maintain the bed in a fluidized state wim over-all circulation of the balls. Wire members criss-crossing through the bed rub against the balls and maintain their surfaces with electrostatic charges. The particulate material in the aerosol adheres to the surfaces of the balls.

  20. Comparison of mold concentrations quantified by MSQPCR in indoor and outdoor air sampled simultaneously

    SciTech Connect

    Meklin, Teija; Reponen, Tina; McKinstry, Craig A.; Cho, Seung H.; Grinshpun, Sergey A.; Nevalainen, Aino; Vepsalainen, Asko; Haugland, Richard A.; Lemasters, Grace; Vesper, Sephen J.

    2007-08-15

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of 36 mold species in dust and in indoor and in outdoor air samples that were taken simultaneously in 17 homes in Cincinnati with no-known water damage. The total spore concentrations in the indoor (I) and outdoor (O) air samples were statistically significantly different and the concentrations in the three sample types of many of the individual species were significantly different (p < 0.05 based on the Wilcoxon Signed Rank Test). The I/O ratios of the averages or geometric means of the individual species were generally less than 1; but these I/O ratios were quite variable ranging from 0.03 for A. sydowii to 1.2 for Acremonium strictum. There were no significant correlations for the 36 specific mold concentrations between the dust samples and the indoor or outdoor air samples (based on the Spearman’s Rho test). The indoor and outdoor air concentrations of 32 of the species were not correlated. Only Aspergillus penicillioides, C. cladosporioides types 1 and 2 and C. herbarum had sufficient data to estimate a correlation at rho > 0.5 with signicance (p < 0.05) In six of these homes, a previous dust sample had been collected and analyzed 2 years earlier. The ERMI© values for the dust samples taken in the same home two years apart were not significantly different (p=0.22) based on Wilcoxon Signed Rank Test.

  1. Pesticide detection in air samples from contrasted houses and in their inhabitants' hair.

    PubMed

    Raeppel, Caroline; Salquèbre, Guillaume; Millet, Maurice; Appenzeller, Brice M R

    2016-02-15

    In order to identify associations between indoor air contamination and human exposure to pesticides, hair samples from 14 persons (9 adults and 5 children below 12 years) were collected simultaneously with the air of their 5 contrasted houses. Three houses were situated in Alsace (France), one in Lorraine (France) and one in Luxembourg (Luxembourg). Houses were located in urban (n=3), semi-urban (n=1) and rural areas (n=1). Twenty five (25) pesticides were detected at least once in indoor air samples and 20 pesticides were detected at least once in hair samples. The comparison between hair and air samples for the same sampling periods shows that pesticides detected in the two matrices were not necessarily associated. Exposure profiles varied from one home to another but also between inhabitants of the same home, suggesting that exposure can be different between inhabitants of the same home. This study demonstrated the usefulness and the complementarity of hair analysis, for the personalized biomonitoring of people exposure to pesticides, and air analysis, for the identification of airborne exposure and house contamination. PMID:26706757

  2. Volatile N-nitrosamines in environmental tobacco smoke: Sampling, analysis, emission factors, and indoor air exposures

    SciTech Connect

    Mahanama, K.R.R.; Daisey, J.M.

    1996-05-01

    A more convenient sampling and analysis method for the volatile N-nitrosamines (VNA) in environmental tobacco smoke (ETS), using commercially available Thermosorb/N cartridges, was developed and validated. Using the method, emission factors for the two major VNA in ETS were determined in a room-sized environmental chamber for six commercial cigarette brands, which together accounted for 62.5% of the total market in California in 1990. The average emission factors were 565{+-}115 and 104{+-}20 ng per cigarette for N-nitrosodimethylamine and N-nitrosopyrrolidine, respectively. The emission factors were used to estimate VNA exposures from ETS in a typical office building and an average residence. Indoor concentrations of N,N-dimethylnitrosamine from ETS for these modeled scenarios were less than 10% of the reported median outdoor concentration. This median outdoor concentration, however, includes many measurements made in source-dominated areas and may be considerably higher than one based on more representative sampling of outdoor air. 35 refs., 4 tabs.

  3. Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.; Pekour, Mikhail S.

    2014-12-02

    The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer

  4. Field evaluation of sampling and analysis for organic pollutants in indoor air

    SciTech Connect

    Chuang, J.C.; Mack, G.A.; Stockrahm, J.W.; Hannan, S.W.; Bridges, C.

    1988-08-01

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in residential air. Residential air sampling was conducted in Columbus, Ohio during the winter of 1986/87. The PAH derivatives were found at much lower levels than their parent PAH. Higher average indoor levels of all but three target compounds were found compared to outdoor levels. The higher outdoor levels of these three compounds (naphthalene dicarboxylic acid anhydride, pyrene dicarboxylic acid anhydride, and 2-nitrofluoranthene) are probably due to atmospheric transformation. Cigarette smoking was identified as the most-significant contributor to indoor levels of PAH and PAH derivatives. Homes with gas-heating systems appeared to have higher pollutant levels compared to homes with electric-heating systems.

  5. Accelerator Mass Spectrometric determination of radiocarbon in stratospheric CO2, retrieved from AirCore sampling.

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Been, Henk A.; Chen, Huilin; Kivi, Rigel; Meijer, Harro A. J.

    2015-04-01

    In this decade, understanding the impact of human activities on climate is one of the key issues of discussion globally. The continuous rise in the concentration of greenhouse gases, e.g., CO2, CH4, etc. in the atmosphere, predominantly due to human activities, is alarming and requires continuous monitoring to understand the dynamics. Radiocarbon is an important atmospheric tracer and one of the many used in the understanding of the global carbon budget, which includes the greenhouse gases like CO2 and CH4. Measurement of 14C (or radiocarbon) in atmospheric CO2 generally requires collection of large air samples (few liters) from which CO2 is extracted and then the concentration of radiocarbon is determined. Currently, Accelerator Mass Spectrometry (AMS) is the most precise, reliable and widely used technique for atmospheric radiocarbon detection. However, the regular collection of air samples from troposphere and stratosphere, for example using aircraft, is prohibitively expensive. AirCore is an innovative atmospheric sampling system, developed by NOAA. It comprises of a long tube descending from a high altitude with one end open and the other closed, and has been demonstrated to be a reliable, cost-effective sampling system for high-altitude profile (up to ~ 30 km) measurements of CH4and CO2(Karion et al. 2010). In Europe, AirCore measurements are being performed on a regular basis near Sodankylä since September 2013. Here we describe the analysis of two such AirCore samples collected in July 2014, Finland, for determining the 14C concentration in stratospheric CO2. The two AirCore samples were collected on consecutive days. Each stratospheric AirCore sample was divided into six fractions, each containing ~ 35 μg CO2 (~9.5 μg C). Each fraction was separately trapped in 1 /4 inch coiled stainless steel tubing for radiocarbon measurements. The procedure for CO2 extraction from the stratospheric air samples; the sample preparation, with samples containing < 10

  6. Canister-based method for monitoring toxic VOCS in ambient air

    SciTech Connect

    McClenny, W.A.; Plell, J.D.; Oliver, K.D.; Holdren, M.W.; Winberry, W.T.

    1991-01-01

    The availability of reliable, accurate and precise monitoring methods for toxic volatile organic compounds (VOCs) is a primary need for state and local agencies addressing daily monitoring requirements related to odor complaints, fugitive emissions, and trend monitoring. The canister-based monitoring method for VOCs is a viable and widely used approach that is based on research and evaluation performed over the past several years. The activity has involved the testing of sample stability of VOCs in canisters and the design of time-integrative samplers. The development of procedures for analysis of samples in canisters, including the procedure for VOC preconcentration from whole air, the treatment of water vapor in the sample, and the selection of an appropriate analytical finish has been accomplished. The canister-based method was initially summarized in the EPA Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air as Method TO-14. Modifications and refinements are being added to Method TO-14 in order to obtain a Statement of Work for the Superfund Contract Laboratory Program for Air. The paper discusses the developments leading to the current status of the canister-based method and provides a critique of the method using results obtained in EPA monitoring networks. (Copyright (c) 1991 - Air and Waste Management Association.)

  7. The contrast model method for the thermodynamical calculation of air-air wet heat exchanger

    NASA Astrophysics Data System (ADS)

    Yuan, Xiugan; Mei, Fang

    1989-02-01

    The 'contrast model' method thermodynamic calculation of air-air crossflow wet heat exchangers with initial air condensation is presented. Contrast-model equations are derived from the actual heat exchanger equations as well as imaginary ones; it is then possible to proceed to a proof that the enthalpy efficiency of the contrast model equations is similar to the temperature efficiency of the dry heat exchanger. Conditions are noted under which it becomes possible to unify thermodynamic calculations for wet and dry heat exchangers.

  8. Method to Estimate the Dissolved Air Content in Hydraulic Fluid

    NASA Technical Reports Server (NTRS)

    Hauser, Daniel M.

    2011-01-01

    In order to verify the air content in hydraulic fluid, an instrument was needed to measure the dissolved air content before the fluid was loaded into the system. The instrument also needed to measure the dissolved air content in situ and in real time during the de-aeration process. The current methods used to measure the dissolved air content require the fluid to be drawn from the hydraulic system, and additional offline laboratory processing time is involved. During laboratory processing, there is a potential for contamination to occur, especially when subsaturated fluid is to be analyzed. A new method measures the amount of dissolved air in hydraulic fluid through the use of a dissolved oxygen meter. The device measures the dissolved air content through an in situ, real-time process that requires no additional offline laboratory processing time. The method utilizes an instrument that measures the partial pressure of oxygen in the hydraulic fluid. By using a standardized calculation procedure that relates the oxygen partial pressure to the volume of dissolved air in solution, the dissolved air content is estimated. The technique employs luminescent quenching technology to determine the partial pressure of oxygen in the hydraulic fluid. An estimated Henry s law coefficient for oxygen and nitrogen in hydraulic fluid is calculated using a standard method to estimate the solubility of gases in lubricants. The amount of dissolved oxygen in the hydraulic fluid is estimated using the Henry s solubility coefficient and the measured partial pressure of oxygen in solution. The amount of dissolved nitrogen that is in solution is estimated by assuming that the ratio of dissolved nitrogen to dissolved oxygen is equal to the ratio of the gas solubility of nitrogen to oxygen at atmospheric pressure and temperature. The technique was performed at atmospheric pressure and room temperature. The technique could be theoretically carried out at higher pressures and elevated

  9. Ambient measurement methods and properties of the 189 Clean Air Act hazardous air pollutants. Final report

    SciTech Connect

    Kelly, T.J.; Mukund, R.; Gordon, S.M.; Hays, M.J.

    1994-03-01

    Measurement methods for the 189 Hazardous Air Pollutants (HAPs) designated in Title III of the 1990 Clean Air Act Amendments are either identified or suggested for all but 10 of the compounds. An extensive list of chemical and physical properties are provided for all compounds. Suggestions for methods development of compounds with no written references are based on the similarity of these chemical and physical properties to other of the HAPs. For 126 of the HAPs, established and documented methods were found; for 53 other HAPs, methods were identified having need for further development; and for 10 HAPs, either no methods or methods requiring extensive development were found. The primary recommendation of the study is that method development be focussed on the 53 HAPs for which additional development is expected to result in reliable methods.

  10. Photoacoustic sample vessel and method of elevated pressure operation

    DOEpatents

    Autrey, Tom; Yonker, Clement R.

    2004-05-04

    An improved photoacoustic vessel and method of photoacoustic analysis. The photoacoustic sample vessel comprises an acoustic detector, an acoustic couplant, and an acoustic coupler having a chamber for holding the acoustic couplant and a sample. The acoustic couplant is selected from the group consisting of liquid, solid, and combinations thereof. Passing electromagnetic energy through the sample generates an acoustic signal within the sample, whereby the acoustic signal propagates through the sample to and through the acoustic couplant to the acoustic detector.

  11. METHODS FOR THE DETERMINATION OF METALS IN ENVIRONMENTAL SAMPLES

    EPA Science Inventory

    Thirteen analytical methods covering 36 analytes which may be present in a ariety of environmental sample types are described in detail. hree of these methods are sample preparation procedures that require a separate determinate step found in other methods in this manual or elsew...

  12. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Representative Sampling Methods I Appendix I to Part 261 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) IDENTIFICATION AND LISTING OF HAZARDOUS WASTE Pt. 261, App. I Appendix I to Part 261—Representative Sampling Methods The methods...

  13. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Representative Sampling Methods I Appendix I to Part 261 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) IDENTIFICATION AND LISTING OF HAZARDOUS WASTE Pt. 261, App. I Appendix I to Part 261—Representative Sampling Methods The methods...

  14. A sample holder for measuring the magnetic properties of air-sensitive compounds

    NASA Astrophysics Data System (ADS)

    Berlie, Adam; Terry, Ian; Szablewski, Marek

    2011-01-01

    A sample holder is reported which has allowed the magnetic characterization of air-sensitive compounds to be made in a Quantum Design Magnetic Properties Measurement System as a function of the applied field (0-5 T), and at temperatures ranging from 2 to 290 K. The sample holder is in the form of a specially designed tube, which is made from high purity quartz, utilizes PTFE (polytetrafluoroethylene) plugs and is reusable. This construction also offers the benefit that no heat treatment of the holder is required during sample loading, making the sample holder suitable for thermally sensitive compounds. The application of this sample holder is demonstrated for the case of Ni(cod)2 (cod = 1,5-cyclooctadiene), a compound that decomposes when exposed to air and/or heat. This material's instability has, so far, prevented the magnetic characterization of the compound, with nickel nanoparticles, a product of the decomposition, usually being measured instead.

  15. 40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false What are the sampling and testing methods for the fuel marker? 80.582 Section 80.582 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Motor Vehicle Diesel Fuel; Nonroad, Locomotive, and Marine...

  16. Systems and methods for self-synchronized digital sampling

    NASA Technical Reports Server (NTRS)

    Samson, Jr., John R. (Inventor)

    2008-01-01

    Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

  17. Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1974-01-01

    The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

  18. A method for selecting training samples based on camera response

    NASA Astrophysics Data System (ADS)

    Zhang, Leihong; Li, Bei; Pan, Zilan; Liang, Dong; Kang, Yi; Zhang, Dawei; Ma, Xiuhua

    2016-09-01

    In the process of spectral reflectance reconstruction, sample selection plays an important role in the accuracy of the constructed model and in reconstruction effects. In this paper, a method for training sample selection based on camera response is proposed. It has been proved that the camera response value has a close correlation with the spectral reflectance. Consequently, in this paper we adopt the technique of drawing a sphere in camera response value space to select the training samples which have a higher correlation with the test samples. In addition, the Wiener estimation method is used to reconstruct the spectral reflectance. Finally, we find that the method of sample selection based on camera response value has the smallest color difference and root mean square error after reconstruction compared to the method using the full set of Munsell color charts, the Mohammadi training sample selection method, and the stratified sampling method. Moreover, the goodness of fit coefficient of this method is also the highest among the four sample selection methods. Taking all the factors mentioned above into consideration, the method of training sample selection based on camera response value enhances the reconstruction accuracy from both the colorimetric and spectral perspectives.

  19. Detection of airborne bacteria in a duck production facility with two different personal air sampling devices for an exposure assessment.

    PubMed

    Martin, Elena; Dziurowitz, Nico; Jäckel, Udo; Schäfer, Jenny

    2015-01-01

    Prevalent airborne microorganisms are not well characterized in industrial animal production buildings with respect to their quantity or quality. To investigate the work-related microbial exposure, personal bioaerosol sampling during the whole working day is recommended. Therefore, bioaerosol sampling in a duck hatchery and a duck house with two personal air sampling devices, a filter-based PGP and a NIOSH particle size separator, was performed. Subsequent, quantitative and qualitative analyses were carried out with" culture independent methods. Total cell concentrations (TCC) determined via fluorescence microscopy showed no difference between the two devices. In average, 8 × 10(6) cells/m(3) were determined in the air of the duck hatchery and 5 × 10(7) cells/m(3) in the air of the duck house. A Generated Restriction Fragment Length Polymorphism (RFLP) pattern revealed deviant bacterial compositions comparing samples collected with both devices. Clone library analyses based on 16S rRNA gene sequence analysis from the hatchery's air showed 65% similarity between the two sampling devices. Detailed 16S rRNA gene sequence analyses showed the occurrence of bacterial species like Acinetobacter baumannii, Enterococcus faecalis, Escherichia sp., and Shigella sp.; and a group of Staphylococcus delphini, S. intermedius, and S. pseudintermedius that provided the evidence of potential exposure to risk group 2 bacteria at the hatchery workplace. Size fractionated sampling with the developed by the Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA) device revealed that pathogenic bacteria would deposit in the inhalable, the thorax, and possibly alveolar dust fraction according to EN481. TCC analysis showed the deposition of bacterial cells in the third stage (< 1μm) at the NIOSH device which implies that bacteria can reach deep into the lungs and contaminate the alveolus after inhalation. Nevertheless, both personal sampling devices

  20. Passive dosimeters for nitrogen dioxide in personal/indoor air sampling: A review

    PubMed Central

    Yu, Chang Ho; Morandi, Maria T.; Weisel, Clifford P.

    2015-01-01

    Accurate measurement of nitrogen dioxide concentrations in both outdoor and indoor environments, including personal exposures, is a fundamental step for linking atmospheric nitrogen dioxide levels to potential health and ecological effects. The measurement has been conducted generally in two ways: active (pumped) sampling and passive (diffusive) sampling. Diffusion samplers, initially developed and used for workplace air monitoring, have been found to be useful and cost-effective alternatives to conventional pumped samplers for monitoring ambient, indoor and personal exposures at the lower concentrations found in environmental settings. Since the 1970s, passive samplers have been deployed for ambient air monitoring in urban and rural sites, and to determine personal and indoor exposure to NO2. This article reviews the development of NO2 passive samplers, the sampling characteristics of passive samplers currently available, and their application in ambient and indoor air monitoring and personal exposure studies. The limitations and advantages of the various passive sampler geometries (i.e., tube, badge, and radial type) are also discussed. This review provides researchers and risk assessors with practical information about NO2 passive samplers, especially useful when designing field sampling strategies for exposure and indoor/outdoor air sampling. PMID:18446185

  1. A RAPID DNA EXTRACTION METHOD FOR PCR IDENTIFICATION OF FUNGAL INDOOR AIR CONTAMINANTS

    EPA Science Inventory

    Following air sampling, fungal DNA needs to be extracted and purified to a state suitable for laboratory use. Our laboratory has developed a simple method of extraction and purification of fungal DNA appropriate for enzymatic manipulation and polymerase chain reaction (PCR) appli...

  2. DOE methods for evaluating environmental and waste management samples.

    SciTech Connect

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  3. Comparison of Methods for Sampling Psocids in Stored Wheat

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Psocids are an emerging problem in stored grain and in grain processing facilities in the United States. We compared several methods for sampling psocids in wheat stored in steel bins – grain trier samples, cardboard refuges on the surface of the grain and near the bin hatch, and automated sampling ...

  4. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    PubMed

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis. PMID:26525264

  5. Passive air sampling of PCBs, PBDEs, and organochlorine pesticides across Europe.

    PubMed

    Jaward, Foday M; Farrar, Nick J; Harner, Tom; Sweetman, Andrew J; Jones, Kevin C

    2004-01-01

    This study presents concurrently sampled ambient air data for a range of persistent organic pollutants at the continental scale. This was achieved using a passive air sampling system, deploying polyurethane foam disks, which was prepared in one laboratory, sealed to prevent contamination, sent out by courier to volunteers participating in different countries, exposed for 6 weeks, collected, resealed, and returned to the laboratory for analysis. Europe was the study area--a region with a history of extensive POPs usage and emission and with marked national differences in population density, the degree of urbanization and industrial/agricultural development. Samplers were deployed at remote/rural/urban locations in 22 countries and analyzed for PCBs, a range of organochlorine pesticides (HCB, alpha-HCH, gamma-HCH, ppDDT, ppDDE), and PBDEs. Calculated air concentrations were in line with those obtained by conventional active air sampling techniques. The geographical pattern of all compounds reflected suspected regional emission patterns and highlighted localized hotspots. PCB and PBDE levels varied by over 2 orders of magnitude; the highest values were detected in areas of high usage and were linked to urbanized areas. HCB was relatively uniformly distributed, reflecting its persistence and high degree of mixing in air. Higher gamma-HCH, ppDDT, and ppDDE levels generally occurred in South and East Europe. PMID:14740714

  6. In-depth analysis of sampling optimization methods

    NASA Astrophysics Data System (ADS)

    Lee, Honggoo; Han, Sangjun; Kim, Myoungsoo; Habets, Boris; Buhl, Stefan; Guhlemann, Steffen; Rößiger, Martin; Bellmann, Enrico; Kim, Seop

    2016-03-01

    High order overlay and alignment models require good coverage of overlay or alignment marks on the wafer. But dense sampling plans are not possible for throughput reasons. Therefore, sampling plan optimization has become a key issue. We analyze the different methods for sampling optimization and discuss the different knobs to fine-tune the methods to constraints of high volume manufacturing. We propose a method to judge sampling plan quality with respect to overlay performance, run-to-run stability and dispositioning criteria using a number of use cases from the most advanced lithography processes.

  7. Air Sampling System for use in monitoring viable and non-viable particulate air quality under dynamic operating conditions of blow/fill/seal processing.

    PubMed

    Probert, Steve; Sinclair, Colin S; Tallentire, Alan

    2002-01-01

    An Air Sampling Link (ASL), employed in conjunction with an Air Sampling Device (ASD) or a laser particle counter, has been developed for sampling flowing air for viable and non-viable particulate analyses. Typically, the ASL could be used to sample filtered air supplied to an air shower of a Blow/Fill/Seal machine operating in the dynamic state. The ASL allows sample volumes of air to be taken from flowing air without significant loss from the sample flow of airborne particles possessing aerodynamic sizes relevant to those found in practice. The link has no moving parts, is steam sterilizable in-situ, and allows for the taking of continuous samples of air without the need for intervention into the 'critical zone' of the filling machine. This article describes (i) the design criteria for the ASL and the ASD, (ii) the rationale underlying the concept of the ASL design, (iii) the collection performance of the ASL against that of a conventional sampling arrangement, and (iv) a functionality assessment of the ASL-based sampling system installed on a Rommelag style 305 B/F/S machine over a seven week period. PMID:12404722

  8. Development and calibration of real-time PCR for quantification of airborne microorganisms in air samples

    NASA Astrophysics Data System (ADS)

    An, Hey Reoun; Mainelis, Gediminas; White, Lori

    This manuscript describes the coupling of bioaerosol collection and the use of real-time PCR (RT-PCR) to quantify the airborne bacteria. The quantity of collected bacteria determined by RT-PCR is compared with conventional quantification techniques, such as culturing, microscopy and airborne microorganism counting by using optical particle counter (OPC). Our data show that an experimental approach used to develop standard curves for use with RT-PCR is critical for accurate sample quantification. Using universal primers we generated 12 different standard curves which were used to quantify model organism Escherichia coli (Migula) Catellani from air samples. Standard curves prepared using a traditional approach, where serially diluted genomic DNA extracted from pure cultured bacteria were used in PCR reaction as a template DNA yielded significant underestimation of sample quantities compared to airborne microorganism concentration as measured by an OPC. The underestimation was especially pronounced when standard curves were built using colony forming units (CFUs). In contrast, the estimate of cell concentration in an air sample by RT-PCR was more accurate (˜60% compared to the airborne microorganism concentration) when the standard curve was built using aerosolized E. coli. The accuracy improved even further (˜100%) when air samples used to build the standard curves were diluted first, then the DNA extracted from each dilution was amplified by the RT-PCR—to mimic the handling of air samples with unknown and possibly low concentration. Therefore, our data show that standard curves used for quantification by RT-PCR needs to be prepared using the same environmental matrix and procedures as handling of the environmental sample in question. Reliance on the standard curves generated with cultured bacterial suspension (a traditional approach) may lead to substantial underestimation of microorganism quantities in environmental samples.

  9. The effect of compressed air foam on the detection of hydrocarbon fuels in fire debris samples.

    PubMed

    Coulson, S A; Morgan-Smith, R K; Noble, D

    2000-01-01

    In 1998/99 the New Zealand Fire Service implemented compressed air foam delivery systems for the suppression of fires in rural areas. This study investigated whether the introduction of the foam to the seat of the fire created any problems in subsequent analyses of fire debris samples. No significant interferences from the foam were found when the samples were analysed by direct headspace using activated carbon strips. The only foam component detected was limonene. PMID:11094822

  10. Method and apparatus for imaging a sample on a device

    DOEpatents

    Trulson, Mark; Stern, David; Fiekowsky, Peter; Rava, Richard; Walton, Ian; Fodor, Stephen P. A.

    2001-01-01

    A method and apparatus for imaging a sample are provided. An electromagnetic radiation source generates excitation radiation which is sized by excitation optics to a line. The line is directed at a sample resting on a support and excites a plurality of regions on the sample. Collection optics collect response radiation reflected from the sample I and image the reflected radiation. A detector senses the reflected radiation and is positioned to permit discrimination between radiation reflected from a certain focal plane in the sample and certain other planes within the sample.

  11. GROUND WATER PURGING AND SAMPLING METHODS: HISTORY VS. HYSTERIA

    EPA Science Inventory

    It has been over 10 years since the low-flow ground water purging and sampling method was initially reported in the literature. The method grew from the recognition that well purging was necessary to collect representative samples, bailers could not achieve well purging, and high...

  12. DEVELOPMENT OF SAMPLING METHODS FOR SOURCE PM10 EMISSIONS

    EPA Science Inventory

    The report describes an investigation of the needs and available techniques for in-stack PM-10 sampling. Discussion includes the conceptualization, development, documentation, and testing of two candidate methods. The first method, Constant Sampling Rate (CSR), is a procedural ap...

  13. Rapid method for sampling metals for materials identification

    NASA Technical Reports Server (NTRS)

    Higgins, L. E.

    1971-01-01

    Nondamaging process similar to electrochemical machining is useful in obtaining metal samples from places inaccessible to conventional sampling methods or where methods would be hazardous or contaminating to specimens. Process applies to industries where metals or metal alloys play a vital role.

  14. Engineering Study of 500 ML Sample Bottle Transportation Methods

    SciTech Connect

    BOGER, R.M.

    1999-08-25

    This engineering study reviews and evaluates all available methods for transportation of 500-mL grab sample bottles, reviews and evaluates transportation requirements and schedules and analyzes and recommends the most cost-effective method for transporting 500-mL grab sample bottles.

  15. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Appendix I to Part 261 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) IDENTIFICATION AND LISTING OF HAZARDOUS WASTE Pt. 261, App. I Appendix I to Part 261—Representative Sampling Methods The methods and equipment used for sampling waste materials will vary with...

  16. Analytical instrument with apparatus and method for sample concentrating

    DOEpatents

    Zaromb, S.

    1986-08-04

    A system for analysis of trace concentrations of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  17. Method for preconcentrating a sample for subsequent analysis

    DOEpatents

    Zaromb, Solomon

    1990-01-01

    A system for analysis of trace concentration of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  18. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    SciTech Connect

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES

  19. A method and fortran program for quantitative sampling in paleontology

    USGS Publications Warehouse

    Tipper, J.C.

    1976-01-01

    The Unit Sampling Method is a binomial sampling method applicable to the study of fauna preserved in rocks too well cemented to be disaggregated. Preliminary estimates of the probability of detecting each group in a single sampling unit can be converted to estimates of the group's volumetric abundance by means of correction curves obtained by a computer simulation technique. This paper describes the technique and gives the FORTRAN program. ?? 1976.

  20. Alternative Methods for Assessing Contaminant Transport from the Vadose Zone to Indoor Air

    NASA Astrophysics Data System (ADS)

    Baylor, K. J.; Lee, A.; Reddy, P.; Plate, M.

    2010-12-01

    Vapor intrusion, which is the transport of contaminant vapors from groundwater and the vadose zone to indoor air, has emerged as a significant human health risk near hazardous waste sites. Volatile organic compounds (VOCs) such as trichloroethylene (TCE) and tetrachloroethylene (PCE) can volatilize from groundwater and from residual sources in the vadose zone and enter homes and commercial buildings through cracks in the slab, plumbing conduits, or other preferential pathways. Assessment of the vapor intrusion pathway typically requires collection of groundwater, soil gas, and indoor air samples, a process which can be expensive and time-consuming. We evaluated three alternative vapor intrusion assessment methods, including 1) use of radon as a surrogate for vapor intrusion, 2) use of pressure differential measurements between indoor/outdoor and indoor/subslab to assess the potential for vapor intrusion, and 3) use of passive, longer-duration sorbent methods to measure indoor air VOC concentrations. The primary test site, located approximately 30 miles south of San Francisco, was selected due to the presence of TCE (10 - 300 ug/L) in shallow groundwater (5 to 10 feet bgs). At this test site, we found that radon was not a suitable surrogate to asses vapor intrusion and that pressure differential measurements are challenging to implement and equipment-intensive. More significantly, we found that the passive, longer-duration sorbent methods are easy to deploy and compared well quantitatively with standard indoor air sampling methods. The sorbent technique is less than half the cost of typical indoor air methods, and also provides a longer duration sample, typically 3 to 14 days rather than 8 to 24 hours for standard methods. The passive sorbent methods can be a reliable, cost-effective, and easy way to sample for TCE, PCE and other VOCs as part of a vapor intrusion investigation.

  1. Development of a wireless air pollution sensor package for aerial-sampling of emissions

    EPA Science Inventory

    A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particulate matter wi...

  2. the nature of air flow near the inlets of blunt dust sampling probes

    NASA Astrophysics Data System (ADS)

    Vincent, J. H.; Hutson, D.; Mark, D.

    This paper sets out to describe the nature of air flow near blunt dust samplers in a way which allows a relatively simple assessment of their performances for collecting dust particles. Of particular importance is the shape of the limiting stream surface which divides the sampled air from that which passes outside the sampler, and how this is affected by the free-stream air velocity, the sampling flow rate, and the shape of the sampler body. This was investigated for two-dimensional and axially-symmetric sampler systems by means of complementary experiments using electrolytic tank potential flow analogues and a wind tunnel respectively. For extreme conditions the flow of air entering the sampling orifice may be wholly divergent or wholly convergent. For a wide range of intermediate conditions, however, the flow first diverges then converges, exhibiting a so-called "spring onion effect". Whichever of these applies for a particular situation, the flow may be considered to consist of two parts, the outer one dominated by the flow about the sampler body and the inner one dominated by the flow into the sampling orifice. Particle transport in this two-part flow may be assessed using ideas borrowed from thin-walled probe theory.

  3. INTERCOMPARISON OF SAMPLING TECHNIQUES FOR TOXIC ORGANIC COMPOUNDS IN INDOOR AIR

    EPA Science Inventory

    People spend a major fraction of their time indoors, and there is concern over exposure to volatile organic compounds present in indoor air. The study was initiated to compare several VOC sampling techniques in an indoor environment. The techniques which were compared include dis...

  4. Development of a wireless air pollution sensor package for aerial-sampling of emissions

    EPA Science Inventory

    A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particula...

  5. ANALYSIS OF VOCS IN AMBIENT AIR USING MULTISORBENT PACKINGS FOR VOC ACCUMULATION AND SAMPLE DRYING

    EPA Science Inventory

    Solid multisorbent packings have been characterized for trapping and release efficiency of trace (10-20 ppbv in humidified zero air) volatile organic compounds (VOCs). he use of a two-stage trapping system reduces sample water content typically by more than 95.5% while maintainin...

  6. COMPARISON OF MOLD CONCENTRATIONS IN INDOOR AND OUTDOOR AIR SAMPLED SIMULTANEOUSLY AND THEN QUANTIFIED BY MSQPCR

    EPA Science Inventory

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 hours in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m3...

  7. CLEANLINESS OF COMMON AIR SAMPLING SORBENTS FOR APPLICATION TO PHENOLIC COMPOUNDS MEASUREMENT USING SUPERCRITICAL FLUID EXTRACTION

    EPA Science Inventory

    The trace-level measurement of phenolic compounds in the ambient air is complicated by the acidic and polar nature of the compounds especially during recovery from the sampling medium. ecently, supercritical fluid extraction (SFE) has been proposed as an alternative extraction me...

  8. NON-POLAR VOLATILE ORGANIC COMPOUNDS IN WHOLE AIR SAMPLES FROM THE AUTOEX STUDIES

    EPA Science Inventory

    Air samples were captured in SUMMA polished stainless steel canisters and returned to the laboratory for analysis of trace level volatile organic compounds by gas chromatography - mass spectrometry. ampling was performed over 2-hour periods at various distances from heavily trave...

  9. Collecting Samples of Workplace Air. Module 8. Vocational Education Training in Environmental Health Sciences.

    ERIC Educational Resources Information Center

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on collecting samples of workplace air. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) collecting information about…

  10. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    PubMed

    Popic, Tony J; Davila, Yvonne C; Wardle, Glenda M

    2013-01-01

    Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2) area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service. PMID:23799127

  11. A Mixed Methods Sampling Methodology for a Multisite Case Study

    ERIC Educational Resources Information Center

    Sharp, Julia L.; Mobley, Catherine; Hammond, Cathy; Withington, Cairen; Drew, Sam; Stringfield, Sam; Stipanovic, Natalie

    2012-01-01

    The flexibility of mixed methods research strategies makes such approaches especially suitable for multisite case studies. Yet the utilization of mixed methods to select sites for these studies is rarely reported. The authors describe their pragmatic mixed methods approach to select a sample for their multisite mixed methods case study of a…

  12. A spatial multicriteria model for determining air pollution at sample locations.

    PubMed

    Réquia Júnior, Weeberb João; Roig, Henrique Llacer; Koutrakis, Petros

    2015-02-01

    Atmospheric pollution in urban centers has been one of the main causes of human illness related to the respiratory and circulatory system. Efficient monitoring of air quality is a source of information for environmental management and public health. This study investigates the spatial patterns of atmospheric pollution using a spatial multicriteria model that helps target locations for air pollution monitoring sites. The main objective was to identify high-priority areas for measuring human exposures to air pollutants as they relate to emission sources. The method proved to be viable and flexible in its application to various areas. PMID:25947058

  13. Preparation of the components of the modified method 5 (method 0010) sampling train for analysis by SW-846 method 8270. Report for December 1992-December 1993

    SciTech Connect

    McGaughey, J.F.; Merrill, R.G.; Bursey, J.T.; Wagoner, D.E.; Jackson, M.D.

    1993-12-01

    In a field evaluation study for semivolatile halogenated organic compounds listed in Title III of the Clean Air Act Amendments of 1990, dynamic spiking experiments using a liquid solution were performed in the field. Two of four quadruple sampling trains were spiked for eight sampling runs. Method 0010 train components were prepared and analyzed in three parts: filter/front halt rinse, XAD-2 resin, and condensate/condensate rinse. Because the results were at variance with results obtained for analytes spiked in laboratory studies and a previous field study, the sample preparation process was investigated in detail. Sample preparation procedures had followed Method 0010, but use of some procedures which were not specifically prohibited by Method 0010 had depressed compound recoveries. To ensure that the sample preparation procedures for Method 0010 train components were clear and unamibiguous, a new protocol to address preparation of Method 0010 train components for Method 8270 analysis was written.

  14. Cryogenic separation of oxygen-argon mixture in natural air samples for isotopic and molecular ratios

    NASA Astrophysics Data System (ADS)

    Habeeb Rahman, Keedakkadan; Abe, Osamu

    2014-05-01

    The discovery of mass independent isotope fractionation in oxygen during the formation of ozone in the stratosphere has initiated a wide application in isotope geochemistry field. Separation of oxygen-argon mixture has become the foundation of high precision analysis of Δ17O and δ(O2/Ar) for geochemical applications. Here we present precise and simplified cryogenic separation of argon oxygen mixture from the atmospheric and dissolved air using 30/60 mesh 5A molecular sieve zeolite. A pioneer study of this method was conducted by Thiemens and Meagher in 1984. The column which is made of glass tube contains about 1.1 grams of molecular sieve zeolite and both ends of column was filled with glass wools. The experimental set up was tested for different combination of molecular sieves and slurry temperatures. We found the most efficient condition for the separation was at a column temperature of -103°C. For complete transfer of O2 and Ar mixture usually takes in 15-20 minutes time. The isotopic ratios of oxygen were analyzed using mass spectrometer (Thermo Fischer Delta Plus) relative to reference oxygen-argon mixture at 3V of m/z 32 for both sample and reference side. The signals of m/z 28, 32, and 40 were measured by dynamically to determine oxygen -argon ratio and to check nitrogen contamination. Repeated measurements of atmospheric air yielded a reproducibility (SE n=80) of 0.006, 0.004 and 0.19‰ for δ17O, δ18O and δO2/Ar respectively. The isotopic and molecular fractionation of argon- oxygen mixture during gas adsorption and desorption while using molecular sieve under liquid nitrogen temperature was studied. We have established a linear relationship governing the effect of 13X and 5A molecular sieves on molecular fractionation. And suggested the use of single 1/8" pellet 13X molecular sieve provided a negligible fractionation.

  15. Determination of trichloroanisole and trichlorophenol in wineries' ambient air by passive sampling and thermal desorption-gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Camino-Sánchez, F J; Bermúdez-Peinado, R; Zafra-Gómez, A; Ruíz-García, J; Vílchez-Quero, J L

    2015-02-01

    The present paper describes the calibration of selected passive samplers used in the quantitation of trichlorophenol and trichloroanisole in wineries' ambient air, by calculating the corresponding sampling rates. The method is based on passive sampling with sorbent tubes and involves thermal desorption-gas chromatography-triple quadrupole mass spectrometry analysis. Three commercially available sorbents were tested using sampling cartridges with a radial design instead of axial ones. The best results were found for Tenax TA™. Sampling rates (R-values) for the selected sorbents were determined. Passive sampling was also used for accurately determining the amount of compounds present in the air. Adequate correlation coefficients between the mass of the target analytes and exposure time were obtained. The proposed validated method is a useful tool for the early detection of trichloroanisole and its precursor trichlorophenol in wineries' ambient air while avoiding contamination of wine or winery facilities. PMID:25576042

  16. A rapid method for the computation of equilibrium chemical composition of air to 15000 K

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.; Erickson, Wayne D.

    1988-01-01

    A rapid computational method has been developed to determine the chemical composition of equilibrium air to 15000 K. Eleven chemically reacting species, i.e., O2, N2, O, NO, N, NO+, e-, N+, O+, Ar, and Ar+ are included. The method involves combining algebraically seven nonlinear equilibrium equations and four linear elemental mass balance and charge neutrality equations. Computational speeds for determining the equilibrium chemical composition are significantly faster than the often used free energy minimization procedure. Data are also included from which the thermodynamic properties of air can be computed. A listing of the computer program together with a set of sample results are included.

  17. Monitoring of air pollution by plants methods and problems

    SciTech Connect

    Steubing, L.; Jager, H.J.

    1985-01-01

    Ecosystem pollution is often discovered too late for preventive measure to be implemented. Papers include the topics of methods and problems of bioindication of air pollution. The participants discussed passive and active biological monitoring, including mapping of natural vegetation (lichens and mosses, for example) and plant exposure. Morphological and microscopical studies, chemical, physiological and biochemical investigations are presented.

  18. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-105 at the Conclusion of 7A.1

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-105 (7 A.1) flight to the ISS is reported. ISS air samples were taken in August 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and surrogate standard recoveries were 64-115%. Pressure tracking indicated no leaks in the canisters.

  19. Evaluation of sorbent materials for the sampling and analysis of phosphine, sulfuryl fluoride and methyl bromide in air.

    PubMed

    Magnusson, R; Rittfeldt, L; Åstot, C

    2015-01-01

    Phosphine (PH3), sulfuryl fluoride (SO2F2) and methyl bromide (CH3Br) are highly toxic chemical substances commonly used for fumigation, i.e., pest control with gaseous pesticides. Residues of fumigation agents constitute a health risk for workers affected, and therefore accurate methods for air sampling and analysis are needed. In this study, three commercial adsorbent tubes; Carbosieve SIII™, Air Toxics™ and Tenax TA™, were evaluated for sampling these highly volatile chemicals in air and their subsequent analysis by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The breakthrough volume (BTV) of each fumigant was experimentally determined on the different adsorbents at concentrations at or above their permissible exposure limits, using a method based on frontal chromatography of generated fumigant atmospheres. Carbosieve SIII™, a molecular sieve possessing a very high specific area, proved to be a better adsorbent than both Air Toxics™ and Tenax TA™, resulting in at least a 4-fold increase of the BTV50%. BTV50% for Carbosieve SIII™ at 20°C was measured as 4.7L/g, 5.5L/g and 126L/g for phosphine, sulfuryl fluoride and methyl bromide, respectively, implying safe sampling volumes of 1.9L, 2.2L and 50L, respectively, for a commercial tube packed with 800mg Carbosieve SIII™. The temperature dependence of BTV was strong for Carbosieve SIII™, showing a reduction of 3-5%/°C in breakthrough volume within the range -20 to 40°C. Furthermore, although Carbosieve SIII™ reportedly has a higher affinity for water than most other adsorbents, relative humidity had only a moderate influence on the retention capacity of phosphine. Overall, the applicability of Carbosieve SIII™ adsorbent sampling in combination with TD-GC-MS analysis was demonstrated for highly volatile fumigants. PMID:25512126

  20. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  1. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-102 at the Conclusion of 5A.1

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-102 (5A.1) flight to the ISS is reported. ISS air samples were taken in late February 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges . A "first-entry" sample of the multipurpose logistics module (MPLM) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 contribution). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample. Formaldehyde is quantified separately.

  2. Determination of selected heavy metals in air samples from the northern part of Jordan.

    PubMed

    Gharaibeh, Ahmad A; El-Rjoob, Abdul-Wahab O; Harb, Mohammed K

    2010-01-01

    In this work, the atmospheric concentrations of selected heavy metals including lead (Pb), iron (Fe), cadmium (Cd), copper (Cu), nickel (Ni), manganese (Mn), and zinc (Zn) were measured for two different sampling sites (urban and rural) in the northern part of Jordan (Irbid city). Samples were collected according to a certain schedule for 1 year. High volume air samplers and glass fiber filters were used to collect the samples. Collected samples were digested using a mixture of analytical grade nitric acid and analytical grade hydrochloric acid, and analyzed to evaluate the levels of heavy metals by atomic absorption spectrophotometry. Six heavy metals (Pb, Fe, Cu, Ni, Mn, and Zn) were measured in all samples; the concentrations of Cd and Co were not detected in Irbid atmosphere by atomic absorption spectroscopy. The results were used to determine the levels of heavy metal pollutants in air, possible sources, and to compare the levels of selected heavy metals in the two studied sites. Aerosols from the rural site have lower concentrations for all the metals compared to those from the urban site. The daily and monthly variations of the elements were investigated. All heavy metals in urban and rural sites reached maximum concentrations in June, July, and August. This is consistent with the increased activities leading to particulate matter emission during the summer period. The enrichment factors with respect to earth crust and correlation coefficients of heavy metals were investigated to predict the possible sources of heavy metals in air. PMID:19083108

  3. Chemical reactivities of ambient air samples in three Southern California communities

    PubMed Central

    Eiguren-Fernandez, Arantza; Di Stefano, Emma; Schmitz, Debra A.; Guarieiro, Aline Lefol Nani; Salinas, Erika M.; Nasser, Elina; Froines, John R.; Cho, Arthur K.

    2015-01-01

    The potential adverse health effects of PM2.5 and vapor samples from three communities that neighbor railyards, Commerce (CM), Long Beach (LB), and San Bernardino (SB), were assessed by determination of chemical reactivities attributed to the induction of oxidative stress by air pollutants. The assays used were dithiothreitol (DTT) and dihydrobenzoic acid (DHBA) based procedures for prooxidant content and a glyceraldehyde-3-phosphate dehydrogenase (GAPDH) assay for electrophiles. Prooxidants and electrophiles have been proposed as the reactive chemical species responsible for the induction of oxidative stress by air pollution mixtures. The PM2.5 samples from CM and LB sites showed seasonal differences in reactivities with higher levels in the winter whereas the SB sample differences were reversed. The reactivities in the vapor samples were all very similar, except for the summer SB samples, which contained higher levels of both prooxidants and electrophiles. The results suggest the observed reactivities reflect general geographical differences rather than direct effects of the railyards. Distributional differences in reactivities were also observed with PM2.5 fractions containing most of the prooxidants (74–81%) and the vapor phase most of the electrophiles (82–96%). The high levels of the vapor phase electrophiles and their potential for adverse biological effects point out the importance of the vapor phase in assessing the potential health effects of ambient air. PMID:25947123

  4. Rapid screening methods for beta-emitters in food samples.

    PubMed

    Vos van Avezathe, A; Brandhoff, P N; van Bourgondiën, M J; Krijger, G C

    2015-03-01

    In case of a nuclear emergency, many samples need to be measured in a short time period. Therefore, it is of vital importance to have a quick and reliable (screening)method. Most methods to determine total beta activity are time-consuming because of extensive sample preparation, such as ashing. In this article three different rapid screening methods for beta emitting nuclides in agriculture, livestock and fishery products were tested and compared to each other, and to an accurate but more time consuming reference method. The goal was to find the method with the optimal trade-off between accuracy, speed and minimal detectable activity (MDA). All of the methods rely on liquid scintillation counting (LSC) or Cerenkov counting, and differ mainly in sample preparation. For matrices with little or no colour, the direct LSC-method is the most accurate and fastest option, while for darker coloured samples this method is not suitable because of high colour quenching. For such samples, two additional methods using a microwave digestion during sample preparation, produced good results. PMID:25577324

  5. Application of the SAMR method to high magnetostrictive samples

    NASA Astrophysics Data System (ADS)

    Sanchez, P.; Lopez, E.; Trujillo, M. C. Sanchez; Aroca, C.

    1988-12-01

    Magnetostriction measurement by using the small angle magnetization rotation method (SAMR) has been performed in high magnetostrictive amorphous samples. To apply the SAMR method to these samples, a theoritical model about the influence of the internal stresses and magnetization distribution has been proposed. The dependence of the magnetostriction, λ s, with the temperature and applied stress was measured in as-cast and in different annealed samples. In the as-cast samples the existence of a stray field and a dependence of λ s with the applied stress has been observed.

  6. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    SciTech Connect

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  7. Report on sampling and analysis of exhaust air at the 221-T and 2706-T buildings

    SciTech Connect

    Stauffer, M.

    1997-09-22

    This report presents analytical results from exhaust air samples collected at stacks 221-T and 2706-T of the T-Plant. The samples were collected with SUMMA canisters over a 24 hour interval and were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data suggest that the buildings had generally low concentrations of volatile organic compounds (< 40 ppbv). However, samples from building 2706-T did have significant amounts of non-target higher-boiling hydrocarbons, probably from a petroleum destination fraction.

  8. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING AIR SAMPLES FOR ANALYSIS OF NEUTRAL PERSISTENT ORGANIC POLLUTANTS (SOP-5.12)

    EPA Science Inventory

    The method is for extracting an indoor and outdoor air sample consisting of a quartz fiber filter and an XAD-2 cartridge for analysis of neutral persistent organic pollutants. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass...

  9. Methods of Visually Determining the Air Flow Around Airplanes

    NASA Technical Reports Server (NTRS)

    Gough, Melvin N; Johnson, Ernest

    1932-01-01

    This report describes methods used by the National Advisory Committee for Aeronautics to study visually the air flow around airplanes. The use of streamers, oil and exhaust gas streaks, lampblack and kerosene, powdered materials, and kerosene smoke is briefly described. The generation and distribution of smoke from candles and from titanium tetrachloride are described in greater detail because they appear most advantageous for general application. Examples are included showing results of the various methods.

  10. Water and entrapped air redistribution in heterogeneous sand sample: Quantitative neutron imaging of the process

    NASA Astrophysics Data System (ADS)

    Snehota, Michal; Jelinkova, Vladimira; Sobotkova, Martina; Sacha, Jan; Vontobel, Peter; Hovind, Jan

    2015-02-01

    Saturated flow in soil with the occurrence of preferential flow often exhibits temporal changes of saturated hydraulic conductivity even during the time scale of a single infiltration event. These effects, observed in a number of experiments done mainly on heterogeneous soils, are often attributed to the changing distribution of water and air in the sample. We have measured the variation of the flow rates during the steady state stage of the constant head ponded infiltration experiment conducted on a packed sample composed of three different grades of sand. The experiment was monitored by quantitative neutron imaging, which provided information about the spatial distribution of water in the sample. Measurements were taken during (i) the initial stages of infiltration by neutron radiography and (ii) during the steady state flow by neutron tomography. A gradual decrease of the hydraulic conductivity has been observed during the first 4 h of the infiltration event. A series of neutron tomography images taken during the quasi-steady state stage showed the trapping of air bubbles in coarser sand. Furthermore, the water content in the coarse sand decreased even more while the water content in the embedded fine sand blocks gradually increased. The experimental results support the hypothesis that the effect of the gradual hydraulic conductivity decrease is caused by entrapped air redistribution and the build up of bubbles in preferential pathways. The trapped air thus restricts the preferential flow pathways and causes lower hydraulic conductivity.

  11. Volatile organic components of air samples collected from Vertical Launch Missile capsules. Summary report

    SciTech Connect

    Tappan, D.V.; Knight, D.R.; Heyder, E.; Weathersby, P.K.

    1988-09-27

    Gas chromatographic/mass spectroscopic analyses are presented for the volatile organic components found in air samples collected from the inboard vents from Vertical Launch System (VLS) missile capsules aboard a 688 class submarine. Similar analyses were also conducted for a sample of the ship's high pressure air used to fill the missile tubes. A wide variety of organics was detected in the air from the missile capsules; and while no unique components have yet been identified, a significant contribution has been shown to be made by pressure-ventilation of the VLS capsules into the submarine atmosphere which is already heavily laden with volatile organic compounds. The most apparent conclusion from these preliminary analyses is that the mixtures of organic components in the air within VLS missile capsules vary greatly from capsule to capsule (and probably from time to time). Many such samples need to be investigated to provide sufficient information to judge the seriousness of the possibility of venting toxic components into the submarine atmosphere during the maintenance or firing of VLS missiles.

  12. Method for using polarization gating to measure a scattering sample

    DOEpatents

    Baba, Justin S.

    2015-08-04

    Described herein are systems, devices, and methods facilitating optical characterization of scattering samples. A polarized optical beam can be directed to pass through a sample to be tested. The optical beam exiting the sample can then be analyzed to determine its degree of polarization, from which other properties of the sample can be determined. In some cases, an apparatus can include a source of an optical beam, an input polarizer, a sample, an output polarizer, and a photodetector. In some cases, a signal from a photodetector can be processed through attenuation, variable offset, and variable gain.

  13. Soyuz 22 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Jams, John T.

    2010-01-01

    Three mini-grab sample containers (m-GSCs) were returned aboard Soyuz 22 because of concerns that new air pollutants were present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The toxicological assessment of 3 m-GSCs from the ISS is shown in Table 1. The recoveries of the 3 standards (as listed above) from the GSCs averaged 103, 95 and 76%, respectively. Recovery from formaldehyde control badges were 90 and 91%.

  14. Transuranic waste characterization sampling and analysis methods manual

    SciTech Connect

    1995-05-01

    The Transuranic Waste Characterization Sampling and Analysis Methods Manual (Methods Manual) provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) for the Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program). This Methods Manual includes all of the testing, sampling, and analytical methodologies accepted by DOE for use in implementing the Program requirements specified in the QAPP.

  15. Organophosphates in aircraft cabin and cockpit air--method development and measurements of contaminants.

    PubMed

    Solbu, Kasper; Daae, Hanne Line; Olsen, Raymond; Thorud, Syvert; Ellingsen, Dag Gunnar; Lindgren, Torsten; Bakke, Berit; Lundanes, Elsa; Molander, Paal

    2011-05-01

    Methods for measurements and the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils among flying personnel in the aviation industry are described. Different sampling methods were applied, including active within-day methods for OPs and VOCs, newly developed passive long-term sample methods (deposition of OPs to wipe surface areas and to activated charcoal cloths), and measurements of OPs in high-efficiency particulate air (HEPA) recirculation filters (n = 6). In total, 95 and 72 within-day OP and VOC samples, respectively, have been collected during 47 flights in six different models of turbine jet engine, propeller and helicopter aircrafts (n = 40). In general, the OP air levels from the within-day samples were low. The most relevant OP in this regard originating from turbine and engine oils, tricresyl phosphate (TCP), was detected in only 4% of the samples (min-max samples (n = 56) and in all HEPA-filters. Other OPs, as dibutylphenyl phosphate (DBPP) and tri-n-butyl phosphate (TnBP) originating from hydraulic oils were more prominent in the samples, illustrated by determination of TnBP in all of the within-day samples collected from airplanes (n = 76, min-max 0.02-4.1 µg m(-3)). All samples were collected under normal flight conditions. However, the TCP concentration during ground testing in an airplane that had experienced leakage of turbine oil with subsequent contamination of the cabin and cockpit air, was an order of magnitude higher as compared to after engine replacement (p = 0.02). PMID:21399836

  16. A random spatial sampling method in a rural developing nation

    PubMed Central

    2014-01-01

    Background Nonrandom sampling of populations in developing nations has limitations and can inaccurately estimate health phenomena, especially among hard-to-reach populations such as rural residents. However, random sampling of rural populations in developing nations can be challenged by incomplete enumeration of the base population. Methods We describe a stratified random sampling method using geographical information system (GIS) software and global positioning system (GPS) technology for application in a health survey in a rural region of Guatemala, as well as a qualitative study of the enumeration process. Results This method offers an alternative sampling technique that could reduce opportunities for bias in household selection compared to cluster methods. However, its use is subject to issues surrounding survey preparation, technological limitations and in-the-field household selection. Application of this method in remote areas will raise challenges surrounding the boundary delineation process, use and translation of satellite imagery between GIS and GPS, and household selection at each survey point in varying field conditions. This method favors household selection in denser urban areas and in new residential developments. Conclusions Random spatial sampling methodology can be used to survey a random sample of population in a remote region of a developing nation. Although this method should be further validated and compared with more established methods to determine its utility in social survey applications, it shows promise for use in developing nations with resource-challenged environments where detailed geographic and human census data are less available. PMID:24716473

  17. Electronic Nose and Use of Bags to Collect Odorous Air Samples in Meat Quality Analysis

    NASA Astrophysics Data System (ADS)

    Sala, G.; Masoero, G.; Battaglini, L. M.; Cornale, P.; Barbera, S.

    2009-05-01

    To test EN reliability and use of bags on meat, 17 bulls (one group of 9 and one of 8) fed similarly, except for a supplementary feedingstuff, were used. Samples were prepared according to the MCS protocol and repeated three times on different days for a total of 51 samples. Bags were used to collect raw and cooked meat air samples, and to test odour changes among samples analysed at different times. The first time analysis was performed immediately after collection then was repeated, 1 hour, 1 day and 1 week later. The Electronic Nose is very discriminant and clear differences were evident among raw, cooked and bags odorous profiles. The highest values were found in cooked samples and the broad range class (W5S) was the most representative. The EN also recognized the two tested feed treatments. In the cooked samples, all sensor responses decrease while time enhances, indicating a progressive chemical variation of the air composition in the bag, with a less correlation shown in the raw samples. When using bags, to avoid bias, is important to fix analysis in order to obtain useful results.

  18. High-throughput liquid-absorption preconcentrator sampling methods

    DOEpatents

    Zaromb, S.

    1994-07-12

    A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis. 12 figs.

  19. High-throughput liquid-absorption preconcentrator sampling methods

    DOEpatents

    Zaromb, Solomon

    1994-01-01

    A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis.

  20. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  1. Results of a Self-Absorption Study on the Versapor 3000 47-mm Filters for Radioactive Particulate Air Stack Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-11-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor® 3000, 47-mm diameter) used at PNNL for self absorption effects. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Large error is associated with the sample filter analysis comparison and subsequently with the estimation of the absorption factor resulting in an inadequate method to estimate losses from self-absorption in the sample filter. The mass loading on the sample filter as determined after digestion and drying was ~0.08 mg cm-2; however, this value may not represent the total filter mass loading given that there may be undetermined losses associated with the digestion process. While it is difficult to determine how much material is imbedded in the filter, observations from the microscopy analysis indicate that the vast majority of the particles remain on the top of the filter. In comparing the results obtained, the continued use of 0.85 as a conservative correction factor is recommended.

  2. Method and sample spinning apparatus for measuring the NMR spectrum of an orientationally disordered sample

    DOEpatents

    Pines, Alexander; Samoson, Ago

    1990-01-01

    An improved NMR apparatus and method are described which substantially improve the resolution of NMR measurements made on powdered or amorphous or otherwise orientationally disordered samples. The apparatus spins the sample about an axis. The angle of the axis is mechanically varied such that the time average of two or more Legendre polynomials are zero.

  3. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  4. Methods for sample size determination in cluster randomized trials

    PubMed Central

    Rutterford, Clare; Copas, Andrew; Eldridge, Sandra

    2015-01-01

    Background: The use of cluster randomized trials (CRTs) is increasing, along with the variety in their design and analysis. The simplest approach for their sample size calculation is to calculate the sample size assuming individual randomization and inflate this by a design effect to account for randomization by cluster. The assumptions of a simple design effect may not always be met; alternative or more complicated approaches are required. Methods: We summarise a wide range of sample size methods available for cluster randomized trials. For those familiar with sample size calculations for individually randomized trials but with less experience in the clustered case, this manuscript provides formulae for a wide range of scenarios with associated explanation and recommendations. For those with more experience, comprehensive summaries are provided that allow quick identification of methods for a given design, outcome and analysis method. Results: We present first those methods applicable to the simplest two-arm, parallel group, completely randomized design followed by methods that incorporate deviations from this design such as: variability in cluster sizes; attrition; non-compliance; or the inclusion of baseline covariates or repeated measures. The paper concludes with methods for alternative designs. Conclusions: There is a large amount of methodology available for sample size calculations in CRTs. This paper gives the most comprehensive description of published methodology for sample size calculation and provides an important resource for those designing these trials. PMID:26174515

  5. Greenhouse gas analysis of air samples collected onboard the CARIBIC passenger aircraft

    NASA Astrophysics Data System (ADS)

    Schuck, T. J.; Brenninkmeijer, C. A. M.; Slemr, F.; Xueref-Remy, I.; Zahn, A.

    2009-08-01

    CARIBIC (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container) is a long-term atmospheric measurement program based on the use of a comprehensive scientific instrument package aboard a commercial passenger aircraft. In addition to real-time measurements, whole air sampling is performed regularly at cruising altitudes in the tropical middle troposphere and the extra-tropical UT/LS region. Air samples are analyzed for greenhouse gases, NMHCs, halocarbons, and trace gas isotopic composition. The routinely performed greenhouse gas analysis comprises gas chromatography measurements of CO2, CH4, N2O and SF6. The air sampling procedure, the GC system and its performance are described. Comparisons with similar systems employed in other laboratories and a comparison with results from a CO2 in-situ analyzer that is also part of the CARIBIC instrumentation are shown. In addition, the time series of CO2, obtained from the collection of 684 samples at latitudes between 30° N and 56° N on 21 round trips out of Germany to different destinations in Asia between November 2005 and October 2008, is presented. A time shift in the seasonal cycle of about one month was observed between the upper troposphere and the tropopause region. For two sets of return flights from Germany to the Philippines the relationship between the four greenhouse gases is briefly discussed.

  6. Field evaluation of personal sampling methods for multiple bioaerosols.

    PubMed

    Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine

    2015-01-01

    Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols. PMID:25799419

  7. Method of soil sampling following subsurface banding of solid manure

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Soil sampling guidelines do not exist for fields fertilized with solid manures applied in bands. The objective of this work was to describe the distribution of mineral nutrients and total C and propose a method of taking soil samples that reflects the fertility level of a field following manure app...

  8. Nominal Weights Mean Equating: A Method for Very Small Samples

    ERIC Educational Resources Information Center

    Babcock, Ben; Albano, Anthony; Raymond, Mark

    2012-01-01

    The authors introduced nominal weights mean equating, a simplified version of Tucker equating, as an alternative for dealing with very small samples. The authors then conducted three simulation studies to compare nominal weights mean equating to six other equating methods under the nonequivalent groups anchor test design with sample sizes of 20,…

  9. Field Evaluation of Personal Sampling Methods for Multiple Bioaerosols

    PubMed Central

    Wang, Chi-Hsun; Chen, Bean T.; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine

    2015-01-01

    Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols. PMID:25799419

  10. A cryopreservation method for Pasteurella multocida from wetland samples

    USGS Publications Warehouse

    Moore, Melody K.; Shadduck, D.J.; Goldberg, D.R.; Samuel, M.D.

    1998-01-01

    A cryopreservation method and improved isolation techniques for detection of Pasteurella multocida from wetland samples were developed. Wetland water samples were collected in the field, diluted in dimethyl sulfoxide (DMSO, final concentration 10%), and frozen at -180 C in a liquid nitrogen vapor shipper. Frozen samples were transported to the laboratory where they were subsequently thawed and processed in Pasteurella multocida selective broth (PMSB) to isolate P. multocida. This method allowed for consistent isolation of 2 to 18 organisms/ml from water seeded with known concentrations of P. multocida. The method compared favorably with the standard mouse inoculation method and allowed for preservation of the samples until they could be processed in the laboratory.

  11. A cryopreservation method for Pasteurella multocida from wetland samples.

    PubMed

    Moore, M K; Shadduck, D J; Goldberg, D R; Samuel, M D

    1998-01-01

    A cryopreservation method and improved isolation techniques for detection of Pasteurella multocida from wetland samples were developed. Wetland water samples were collected in the field, diluted in dimethyl sulfoxide (DMSO, final concentration 10%), and frozen at -180 C in a liquid nitrogen vapor shipper. Frozen samples were transported to the laboratory where they were subsequently thawed and processed in Pasteurella multocida selective broth (PMSB) to isolate P. multocida. This method allowed for consistent isolation of 2 to 18 organisms/ml from water seeded with known concentrations of P. multocida. The method compared favorably with the standard mouse inoculation method and allowed for preservation of the samples until they could be processed in the laboratory. PMID:9476245

  12. Sample water removal method in volatile organic compound analysis based on diffusion through poly(vinyl fluoride) film.

    PubMed

    Beghi, Sandra; Guillot, Jean-Michel

    2006-09-15

    The humidity caught during air sampling or sample storage causes various problems during volatile organic compound (VOC) analysis and gives unreliable results. In this study, water vapour diffusion capacities through poly(vinyl fluoride) Tedlar, fluoroethylene propylene Teflon and Flex foil film were compared. A new approach to humidity removal has been tested for moderately polluted atmospheres. This approach consists in using the water vapour diffusion property of Tedlar film to remove humidity from bag samples containing a mixture of ten VOCs at 500 ppbv each in a 70% relative humidity atmosphere. The sampling bags were placed in a chamber flushed by a dry air stream at less than 5% relative humidity. After a few hours in the chamber, the samples in the Tedlar bags were dry (relative humidity <5%) and did not show significant VOC loss. This sample water removal (SWR) method is especially interesting as a pretreatment before air sampling on water sensitive adsorbents. PMID:16828784

  13. Neutron activation analysis of certified samples by the absolute method

    NASA Astrophysics Data System (ADS)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  14. Probability Sampling Method for a Hidden Population Using Respondent-Driven Sampling: Simulation for Cancer Survivors.

    PubMed

    Jung, Minsoo

    2015-01-01

    When there is no sampling frame within a certain group or the group is concerned that making its population public would bring social stigma, we say the population is hidden. It is difficult to approach this kind of population survey-methodologically because the response rate is low and its members are not quite honest with their responses when probability sampling is used. The only alternative known to address the problems caused by previous methods such as snowball sampling is respondent-driven sampling (RDS), which was developed by Heckathorn and his colleagues. RDS is based on a Markov chain, and uses the social network information of the respondent. This characteristic allows for probability sampling when we survey a hidden population. We verified through computer simulation whether RDS can be used on a hidden population of cancer survivors. According to the simulation results of this thesis, the chain-referral sampling of RDS tends to minimize as the sample gets bigger, and it becomes stabilized as the wave progresses. Therefore, it shows that the final sample information can be completely independent from the initial seeds if a certain level of sample size is secured even if the initial seeds were selected through convenient sampling. Thus, RDS can be considered as an alternative which can improve upon both key informant sampling and ethnographic surveys, and it needs to be utilized for various cases domestically as well. PMID:26107223

  15. Continuous monitoring of polychlorinated biphenyls in air using direct sampling APCI/ITMS

    NASA Astrophysics Data System (ADS)

    Yamada, Masuyoshi; Suga, Masao; Waki, Izumi; Sakamoto, Masami; Morita, Masatoshi

    2005-06-01

    We report a continuous monitoring system of polychlorinated biphenyls (PCBs) in air, which uses direct sampling atmospheric pressure chemical ionization (APCI)/ion trap mass spectrometry (ITMS). In APCI, humidity in the atmosphere, which fluctuates from 0 to 10 vol.%, influences PCB sensitivity. In dry air (0.5% humidity), the detection limits of Di- to Hp-chlorinated biphenyls (CB) are 0.01-0.44 [mu]g/Nm3 ([mu]g/m3 at normal condition) with time resolution of 1 min, whereas the sensitivity decreases to less than 1/10 when water vapor concentration is 10 vol.%. The sensitivity decrease is calibrated in real-time using an internal standard, trichlorophenol. In order to obtain the calibration accuracy of +/-30%, we dilute the sample gas by dry air, decreasing the water vapor concentration below 1%. We applied the monitor to measure Di- to Hp-CB in ventilation air from a PCB decomposition plant. The monitored PCB concentration levels agreed well with that by high-resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS).

  16. Field sampling method for quantifying volatile sulfur compounds from animal feeding operations

    NASA Astrophysics Data System (ADS)

    Trabue, Steven; Scoggin, Kenwood; Mitloehner, Frank; Li, Hong; Burns, Robert; Xin, Hongwei

    Volatile sulfur compounds (VSCs) are a major class of chemicals associated with odor from animal feeding operations (AFOs). Identifying and quantifying VSCs in air is challenging due to their volatility, reactivity, and low concentrations. In the present study, a canister-based method collected whole air in fused silica-lined (FSL) mini-canister (1.4 L) following passage through a calcium chloride drying tube. Sampled air from the canisters was removed (10-600 mL), dried, pre-concentrated, and cryofocused into a GC system with parallel detectors (mass spectrometer (MS) and pulsed flame photometric detector (PFPD)). The column effluent was split 20:1 between the MS and PFPD. The PFPD equimolar sulfur response enhanced quantitation and the location of sulfur peaks for mass spectral identity and quantitation. Limit of quantitation for the PFPD and MSD was set at the least sensitive VSC (hydrogen sulfide) and determined to be 177 and 28 pg S, respectively, or 0.300 and 0.048 μg m -3 air, respectively. Storage stability of hydrogen sulfide and methanethiol was problematic in warm humid air (25 °C, 96% relative humidity (RH)) without being dried first, however, stability in canisters dried was still only 65% after 24 h of storage. Storage stability of hydrogen sulfide sampled in the field at a swine facility was over 2 days. The greater stability of field samples compared to laboratory samples was due to the lower temperature and RH of field samples compared to laboratory generated samples. Hydrogen sulfide was the dominant odorous VSCs detected at all swine facilities with methanethiol and dimethyl sulfide detected notably above their odor threshold values. The main odorous VSC detected in aged poultry litter was dimethyl trisulfide. Other VSCs above odor threshold values for poultry facilities were methanethiol and dimethyl sulfide.

  17. DOE methods for evaluating environmental and waste management samples

    SciTech Connect

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  18. Method and apparatus for imaging a sample on a device

    DOEpatents

    Trulson, Mark; Stern, David; Fiekowsky, Peter; Rava, Richard; Walton, Ian; Fodor, Stephen P. A.

    1996-01-01

    The present invention provides methods and systems for detecting a labeled marker on a sample located on a support. The imaging system comprises a body for immobilizing the support, an excitation radiation source and excitation optics to generate and direct the excitation radiation at the sample. In response, labeled material on the sample emits radiation which has a wavelength that is different from the excitation wavelength, which radiation is collected by collection optics and imaged onto a detector which generates an image of the sample.

  19. System and method for measuring fluorescence of a sample

    DOEpatents

    Riot, Vincent J

    2015-03-24

    The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

  20. Convenient mounting method for electrical measurements of thin samples

    NASA Technical Reports Server (NTRS)

    Matus, L. G.; Summers, R. L.

    1986-01-01

    A method for mounting thin samples for electrical measurements is described. The technique is based on a vacuum chuck concept in which the vacuum chuck simultaneously holds the sample and established electrical contact. The mounting plate is composed of a glass-ceramic insulating material and the surfaces of the plate and vacuum chuck are polished. The operation of the vacuum chuck is examined. The contacts on the sample and mounting plate, which are sputter-deposited through metal masks, are analyzed. The mounting method was utilized for van der Pauw measurements.

  1. A quantitative evaluation of two methods for preserving hair samples

    USGS Publications Warehouse

    Roon, David A.; Waits, L.P.; Kendall, K.C.

    2003-01-01

    Hair samples are an increasingly important DNA source for wildlife studies, yet optimal storage methods and DNA degradation rates have not been rigorously evaluated. We tested amplification success rates over a one-year storage period for DNA extracted from brown bear (Ursus arctos) hair samples preserved using silica desiccation and -20C freezing. For three nuclear DNA microsatellites, success rates decreased significantly after a six-month time point, regardless of storage method. For a 1000 bp mitochondrial fragment, a similar decrease occurred after a two-week time point. Minimizing delays between collection and DNA extraction will maximize success rates for hair-based noninvasive genetic sampling projects.

  2. STS-65 Commander Cabana and PLC Hieb take air sample at IML-2 Rack 7 NIZEMI

    NASA Technical Reports Server (NTRS)

    1994-01-01

    STS-65 Commander Robert D. Cabana (right) and Payload Commander (PLC) Richard J. Hieb take an air sample inside the International Microgravity Laboratory 2 (IML-2) spacelab science module. The two crewmembers are in front of Rack 7 which contains the large isothermal furnace (LIF) and slow rotating centrifuge microscope (NIZEMI). The photo was among the first group released by NASA following the two-week IML-2 mission aboard the Space Shuttle Columbia, Orbiter Vehicle (OV) 102.

  3. Organic toxicants in air and precipitation samples from the Lake Michigan area

    SciTech Connect

    Harlin, K.S.; Sweet, C.W.; Gatz, D.F.

    1995-12-31

    Measurements of PCBs, organochlorine insecticides, PAHs, and atrazine were made in air and precipitation samples collected at regionally-representative locations near Lake Michigan from 1992-1995. The purpose of these measurements was to provide information needed to estimate the atmospheric deposition of organic toxicants to Lake Michigan. Twenty-four hour samples of airborne particles and vapor were collected at 12-day intervals on quartz fiber filters and XAD-2 resin vapor traps using modified high volume sampleers. Twenty-eight day precipitation samples were collected using wet-only samplers with stainless steel sampling surfaces and heated enclosure containing an XAD-2 resin adsorption column. Samples were Soxhlet extracted for 24 hours with hexane:acetone (1:1), and concentrated by rotary evaporation. Interferences were removed and the samples separated into analyte groups by silica gel chromatography. Four fractions were collected for GC-ECD and GC-Ion Trap MS analyses. Ten pesticides, 101 PCB congeners, 18 PAHs, and atrazine were measured in all samples. Quality assurance was maintained by including field duplicate samples, field blanks, alboratory matrix spikes, laboratory matrix blanks, and laboratory surrogate spikes in the sampling/analytical protocols. Preliminary results from urban and remote sites show geographical variations in the concentrations of some toxicants due to contributions from local sources. For all sites the total PCB levels are higher in the vapor phase than the particulate phase and show strong seasonal variations. Seasonal variations were also observed for several pesticides.

  4. Ultimate detectability of volatile organic compounds: how much further can we reduce their ambient air sample volumes for analysis?

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2012-10-01

    To understand the ultimately lowest detection range of volatile organic compounds (VOCs) in air, application of a high sensitivity analytical system was investigated by coupling thermal desorption (TD) technique with gas chromatography (GC) and time-of-flight (TOF) mass spectrometry (MS). The performance of the TD-GC/TOF MS system was evaluated using liquid standards of 19 target VOCs prepared in the range of 35 pg to 2.79 ng per μL. Studies were carried out using both total ion chromatogram (TIC) and extracted ion chromatogram (EIC) mode. EIC mode was used for calibration to reduce background and to improve signal-to-noise. The detectability of 19 target VOCs, if assessed in terms of method detection limit (MDL, per US EPA definition) and limit of detection (LOD), averaged 5.90 pg and 0.122 pg, respectively, with the mean coefficient of correlation (R(2)) of 0.9975. The minimum quantifiable mass of target analytes, when determined using real air samples by the TD-GC/TOF MS, is highly comparable to the detection limits determined experimentally by standard. In fact, volumes for the actual detection of the major aromatic VOCs like benzene, toluene, and xylene (BTX) in ambient air samples were as low as 1.0 mL in the 0.11-2.25 ppb range. It was thus possible to demonstrate that most target compounds including those in low abundance could be reliably quantified at concentrations down to 0.1 ppb at sample volumes of less than 10 mL. The unique sensitivity of this advanced analytical system can ultimately lead to a shift in field sampling strategy with smaller air sample volumes facilitating faster, simpler air sampling (e.g., use of gas syringes rather than the relative complexity of pumps or bags/canisters), with greatly reduced risk of analyte breakthrough and minimal interference, e.g., from atmospheric humidity. The improved detection limits offered by this system can also enhance accuracy and measurement precision. PMID:22934885

  5. Isotopic air sampling in a tallgrass prairie to partition net ecosystem CO2 exchange

    NASA Astrophysics Data System (ADS)

    Lai, Chun-Ta; Schauer, Andrew J.; Owensby, Clenton; Ham, Jay M.; Ehleringer, James R.

    2003-09-01

    Stable isotope ratios of various ecosystem components and net ecosystem exchange (NEE) CO2 fluxes were measured in a C3-C4 mixture tallgrass prairie near Manhattan, Kansas. The July 2002 study period was chosen because of contrasting soil moisture contents, which allowed us to address the effects of drought on photosynthetic CO2 uptake and isotopic discrimination. Significantly higher NEE fluxes were observed for both daytime uptake and nighttime respiration during well-watered conditions when compared to a drought period. Given these differences, we investigated two carbon-flux partitioning questions: (1) What proportions of NEE were contributed by C3 versus C4 species? (2) What proportions of NEE fluxes resulted from canopy assimilation versus ecosystem respiration? To evaluate these questions, air samples were collected every 2 hours during daytime for 3 consecutive days at the same height as the eddy covariance system. These air samples were analyzed for both carbon isotope ratios and CO2 concentrations to establish an empirical relationship for isoflux calculations. An automated air sampling system was used to collect nighttime air samples to estimate the carbon isotope ratios of ecosystem respiration (δR) at weekly intervals for the entire growing season. Models of C3 and C4 photosynthesis were employed to estimate bulk canopy intercellular CO2 concentration in order to calculate photosynthetic discrimination against 13C. Our isotope/NEE results showed that for this grassland, C4 vegetation contributed ˜80% of the NEE fluxes during the drought period and later ˜100% of the NEE fluxes in response to an impulse of intense precipitation. For the entire growing season, the C4 contribution ranged from ˜68% early in the spring to nearly 100% in the late summer. Using an isotopic approach, the calculated partitioned respiratory fluxes were slightly greater than chamber-measured estimates during midday under well-watered conditions. In addition, time series

  6. The alias method: A fast, efficient Monte Carlo sampling technique

    SciTech Connect

    Rathkopf, J.A.; Edwards, A.L. ); Smidt, R.K. )

    1990-11-16

    The alias method is a Monte Carlo sampling technique that offers significant advantages over more traditional methods. It equals the accuracy of table lookup and the speed of equal probable bins. The original formulation of this method sampled from discrete distributions and was easily extended to histogram distributions. We have extended the method further to applications more germane to Monte Carlo particle transport codes: continuous distributions. This paper presents the alias method as originally derived and our extensions to simple continuous distributions represented by piecewise linear functions. We also present a method to interpolate accurately between distributions tabulated at points other than the point of interest. We present timing studies that demonstrate the method's increased efficiency over table lookup and show further speedup achieved through vectorization. 6 refs., 2 figs., 1 tab.

  7. Extending the alias Monte Carlo sampling method to general distributions

    SciTech Connect

    Edwards, A.L.; Rathkopf, J.A. ); Smidt, R.K. )

    1991-01-07

    The alias method is a Monte Carlo sampling technique that offers significant advantages over more traditional methods. It equals the accuracy of table lookup and the speed of equal probable bins. The original formulation of this method sampled from discrete distributions and was easily extended to histogram distributions. We have extended the method further to applications more germane to Monte Carlo particle transport codes: continuous distributions. This paper presents the alias method as originally derived and our extensions to simple continuous distributions represented by piecewise linear functions. We also present a method to interpolate accurately between distributions tabulated at points other than the point of interest. We present timing studies that demonstrate the method's increased efficiency over table lookup and show further speedup achieved through vectorization. 6 refs., 12 figs., 2 tabs.

  8. Microbial Air and Surface Monitoring Results from International Space Station Samples

    NASA Technical Reports Server (NTRS)

    Ott, C. Mark; Bruce, Rebekah J.; Castro, Victoria A.; Novikova, Natalia D.; Pierson, D. L.

    2005-01-01

    Over the course of long-duration spaceflight, spacecraft develop a microbial ecology that directly interacts with the crew of the vehicle. While most microorganisms are harmless or beneficial to the inhabitants of the vehicle, the presence of medically significant organisms appearing in this semi-closed environment could adversely affect crew health and performance. The risk of exposure of the crew to medically significant organisms during a mission is estimated using information gathered during nominal and contingency environmental monitoring. Analysis of the air and surface microbiota in the habitable compartments of the International Space Station (ISS) over the last four years indicate a high presence of Staphylococcus species reflecting the human inhabitants of the vehicle. Generally, air and surface microbial concentrations are below system design specifications, suggesting a lower risk of contact infection or biodegradation. An evaluation of sample frequency indicates a decrease in the identification of new species, suggesting a lower potential for unknown microorganisms to be identified. However, the opportunistic pathogen, Staphylococcus aureus, has been identified in 3 of the last 5 air samples and 5 of the last 9 surface samples. In addition, 47% of the coagulase negative Staphylococcus species that were isolated from the crew, ISS, and its hardware were found to be methicillin resistance. In combination, these observations suggest the potential of methicillin resistant infectious agents over time.

  9. Technical assessment of TRUSAF for compliance with work place air sampling. Revision 1

    SciTech Connect

    Butler, J.D.

    1995-01-23

    The purpose of this Technical Work Document is to satisfy WHC-CM-1-6, the ``WHC Radiological Control Manual.`` This first revision of the original Supporting Document covers the period from January 1, 1994 to December 31, 1994. WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. this document also provides an evaluation of the compliance of the TRUSAF workplace air sampling program to the criteria, standards, and requirements and documents. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  10. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 1

    SciTech Connect

    Olsen, P.A.

    1994-09-21

    WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE N 5480.6 ``US Department of Energy Radiological Control Manual`` as it applies to programs at Hanford which are now overseen by WHC. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of Tank Farms` workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  11. The use of Whatman-41 filters for high volume air sampling

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1975-01-01

    The feasibility of using W41 filter media on a routine TSP high-volume monitoring network was determined by comparison with glass fiber (GF) filtering. Results indicate that suspended particulate samples from GF filters averaged slightly, but not significantly, higher than those from Whatman-41 filters. Some extra handling procedures were required to avoid errors due to the hygroscopic nature of W41 filters; these added procedures are not overly burdensome, however, and they allow the performance of analytical work, thus extending the capabilities of high-volume sampling. It was demonstrated that W41 filters are practical for air quality monitoring and elemental analysis in environments similar to Cleveland's.

  12. The nature of air pollution and the methods available for measuring it

    PubMed Central

    Ellison, J. McK.

    1965-01-01

    At present the principal sources of energy in Europe are coal and oil and fuels derived from them, and in European towns air pollution consists mainly of their combustion products. These combustion products naturally divide into two categories, gaseous and particulate, which are very different chemically and which behave very differently when they are near collecting surfaces; they therefore require very different techniques both for collecting and for estimating samples. Some methods of measurement, suitable for everyday routine use in Europe, are described; these offer a compromise between completeness and economy, and can help to give a general outline of the air pollution situation without undue complexity or prohibitive cost. PMID:14315712

  13. A new analysis system for whole air sampling: description and results from 2013 SENEX

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Gilman, J.; Dumas, M.; Hughes, D.; Jaksich, A.; Hatch, C. D.; Graus, M.; Warneke, C.; Apel, E. C.; Hornbrook, R. S.; Holloway, J. S.; De Gouw, J. A.

    2014-12-01

    Accurate measurement of volatile organic compounds (VOCs) in the troposphere is critical for the understanding of emissions and physical and chemical processes that can impact both air quality and climate. Airborne VOC measurements have proven especially challenging due to the requirement of both high sensitivity (pptv) and short sample collection times (≤15 s) to maximize spatial resolution and sampling frequency for targeted plume analysis. The use of stainless steel canisters to collect whole air samples (WAS) for post-flight analysis has been pioneered by the groups of D. Blake and E. Atlas [Blake et al., 1992; Atlas et al., 1993]. For the 2013 Southeast Nexus Study (SENEX), the NOAA ESRL CSD laboratory undertook WAS measurements for the first time. This required the construction of three new, highly-automated, and field-portable instruments designed to sample, analyze, and clean the canisters for re-use. Analysis was performed with a new custom-built gas chromatograph-mass spectrometer system. The instrument pre-concentrates analyte cryostatically into two parallel traps by means of a Stirling engine, a novel technique which obviates the need for liquid nitrogen to reach trapping temperatures of -175C. Here we present an evaluation of the retrieval of target VOC species from WAS canisters. We discuss the effects of humidity and sample age on the analyte, particularly upon C8+ alkane and aromatic species and biogenic species. Finally, we present results from several research flights during SENEX that targeted emissions from oil/natural gas production.

  14. Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.

    2011-07-20

    This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

  15. Learning styles: The learning methods of air traffic control students

    NASA Astrophysics Data System (ADS)

    Jackson, Dontae L.

    In the world of aviation, air traffic controllers are an integral part in the overall level of safety that is provided. With a number of controllers reaching retirement age, the Air Traffic Collegiate Training Initiative (AT-CTI) was created to provide a stronger candidate pool. However, AT-CTI Instructors have found that a number of AT-CTI students are unable to memorize types of aircraft effectively. This study focused on the basic learning styles (auditory, visual, and kinesthetic) of students and created a teaching method to try to increase memorization in AT-CTI students. The participants were asked to take a questionnaire to determine their learning style. Upon knowing their learning styles, participants attended two classroom sessions. The participants were given a presentation in the first class, and divided into a control and experimental group for the second class. The control group was given the same presentation from the first classroom session while the experimental group had a group discussion and utilized Middle Tennessee State University's Air Traffic Control simulator to learn the aircraft types. Participants took a quiz and filled out a survey, which tested the new teaching method. An appropriate statistical analysis was applied to determine if there was a significant difference between the control and experimental groups. The results showed that even though the participants felt that the method increased their learning, there was no significant difference between the two groups.

  16. Air cushion vehicle conductive/semiconductive flexible skirt, and method

    NASA Astrophysics Data System (ADS)

    Cavenagh, Richard A.; Dyke, Raymond W.

    1990-03-01

    Discussed here is a method for dissipating static electrical energy from air cushion vehicles when operating more particularly in cold, low humidity environments, which method involves fabricating the skirt assembly from a flexible sheet material of at least semiconductive character, which will provide a suitable dissipating grounding pathway to discharge potential static electrical energy generated during the aforesaid operation. The method includes using a coated flexible fabric material having at least one of its opposite surfaces coated with an elastomeric abrasion-resistant material, and embedding a plurality of electrically conductive flexible strands at least partially within said flexible fabric material, or alternatively embedding electrically conductive particles or fibers in a generally uniformly manner throughout a forming of its elastomeric composition. The invention also is directed specifically to/on an air cushion vehicle skirt component comprised of electrically conductive composite flexible sheet material having sufficient conductive characteristics to provide a near constant dissipation grounding pathway from said vehicle for any substantial build up of generated static electrical energy, more particularly when the air cushion vehicle is operating in cold, low humidity environments.

  17. COMPARISON OF MACROINVERTEBRATE SAMPLING METHODS FOR NONWADEABLE STREAMS

    EPA Science Inventory

    The bioassessment of nonwadeable streams in the United States is increasing, but methods for these systems are not as well developed as for wadeable streams. In this study, we compared six benthic macroinvertebrate field sampling methods for nonwadeable streams based on those us...

  18. The Circle-Arc Method for Equating in Small Samples

    ERIC Educational Resources Information Center

    Livingston, Samuel A.; Kim, Sooyeon

    2009-01-01

    This article suggests a method for estimating a test-score equating relationship from small samples of test takers. The method does not require the estimated equating transformation to be linear. Instead, it constrains the estimated equating curve to pass through two pre-specified end points and a middle point determined from the data. In a…

  19. The Precision Efficacy Analysis for Regression Sample Size Method.

    ERIC Educational Resources Information Center

    Brooks, Gordon P.; Barcikowski, Robert S.

    The general purpose of this study was to examine the efficiency of the Precision Efficacy Analysis for Regression (PEAR) method for choosing appropriate sample sizes in regression studies used for precision. The PEAR method, which is based on the algebraic manipulation of an accepted cross-validity formula, essentially uses an effect size to…

  20. Sampling and analysis of trace-organic constituents in ambient and workplace air at coal-conversion facilities

    SciTech Connect

    Flotard, R D

    1980-07-01

    A review of the recent literature reveals that current sampling procedures involve the use of glass fiber filters for particulate-sorbed organics and sorbent resins such as Tenax GC and XAD-2 for vapor-phase organics. Ultra trace-organic analysis of air pollutants or particulates may require the collection of a large (1000 to 3000 m/sup 3/) sample by a high volume air sampler. Personal air sampling requires a smaller (approx. = 0.5 m/sup 3/) and a portable collection apparatus. Trapped organic chemicals are recovered by solvent extraction or thermal desorption of the collector. Recovered organics are separated by using liquid chromatography or gas chromatography and are identified by ultraviolet or fluorescence spectroscopy, gas chromatography, or mass spectrometry. For quantification, standards are added to the air stream during sampling or to the filter or resin following sampling. Analysis of the requirement for air sampling in and around coal conversion plants, coupled with the findings of the literature review, indicates that a combined particulate-filter and solvent-extractable-resin sampling unit should be used to collect both particulate-sorbed organics and vapor-phase organics from workplace or ambient plant air. Such a sampler was developed for stationary, moderate-to-high-volume air sampling. Descriptions of the sampler are provided together with sampling efficiency information and recommendations for a sampling procedure.

  1. Standard methods for sampling North American freshwater fishes

    USGS Publications Warehouse

    Bonar, Scott A.; Hubert, Wayne A.; Willis, David W.

    2009-01-01

    This important reference book provides standard sampling methods recommended by the American Fisheries Society for assessing and monitoring freshwater fish populations in North America. Methods apply to ponds, reservoirs, natural lakes, and streams and rivers containing cold and warmwater fishes. Range-wide and eco-regional averages for indices of abundance, population structure, and condition for individual species are supplied to facilitate comparisons of standard data among populations. Provides information on converting nonstandard to standard data, statistical and database procedures for analyzing and storing standard data, and methods to prevent transfer of invasive species while sampling.

  2. Beryllium Wipe Sampling (differing methods - differing exposure potentials)

    SciTech Connect

    Kerr, Kent

    2005-03-09

    This research compared three wipe sampling techniques currently used to test for beryllium contamination on room and equipment surfaces in Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling without a wetting agent, with water-moistened wipe materials, and by methanol-moistened wipes. Analysis indicated that methanol-moistened wipe sampling removed about twice as much beryllium/oil-film surface contamination as water-moistened wipes, which removed about twice as much residue as dry wipes. Criteria at 10 CFR 850.30 and .31 were established on unspecified wipe sampling method(s). The results of this study reveal a need to identify criteria-setting method and equivalency factors. As facilities change wipe sampling methods among the three compared in this study, these results may be useful for approximate correlations. Accurate decontamination decision-making depends on the selection of appropriate wetting agents for the types of residues and surfaces. Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced removal efficiency such as methanol when surface contamination includes oil mist residue.

  3. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  4. Air pollution studies using PIXE and ICP methods

    NASA Astrophysics Data System (ADS)

    Stihi, Claudia; Bancuta, Anca; Popescu, I. V.; Virgolici, M.; Cimpoca, V.; Gugiu, M.; Vlaicu, Gh

    2006-05-01

    In the present work the moss biomonitoring technique and the combination of two analytical techniques - Particle Induced X-ray Emission (PIXE) [3] and Inductively Coupled Plasma (ICP) [4] - were applied for assessing environmental situation from the point of view of air polluting along the transect from north to south of the Dambovita County. PIXE analysis at the Tandem Accelerator FN-8 of the National Institute of Nuclear Physics - Horia Hulubei of Magurele, Bucharest, allowed determination of P, S, Cl, K, Ca, Mn, Fe, Ni, Cu, Zn, As, Sr, Cd and Pb in samples. ICP analyses were made using a Baird ICP2070 - Sequential Plasma Spectrometer in Targoviste and we determined in samples the concentration of Li, B, Na, and Mg together with Cd and Pb. The obtained results will permit to determine the regional extent of heavy metals and toxic elements atmospheric pollution and to identify specially affected areas and local sources of

  5. Continuous air agglomeration method for high carbon fly ash beneficiation

    DOEpatents

    Gray, McMahon L.; Champagne, Kenneth J.; Finseth, Dennis H.

    2000-01-01

    The carbon and mineral components of fly ash are effectively separated by a continuous air agglomeration method, resulting in a substantially carboree mineral stream and a highly concentrated carbon product. The method involves mixing the fly ash comprised of carbon and inorganic mineral matter with a liquid hydrocarbon to form a slurry, contacting the slurry with an aqueous solution, dispersing the hydrocarbon slurry into small droplets within the aqueous solution by mechanical mixing and/or aeration, concentrating the inorganic mineral matter in the aqueous solution, agglomerating the carbon and hydrocarbon in the form of droplets, collecting the droplets, separating the hydrocarbon from the concentrated carbon product, and recycling the hydrocarbon.

  6. Continuous air Agglomeration Method for high Carbon fly ash Beneficiation

    SciTech Connect

    Gray, McMahan L.; Champagne, Kenneth J.; Finseth, Dennis H.

    1998-09-29

    The carbon and mineral components of fly ash are effectively separated by a continuous air agglomeration method, resulting in a substantially carbon-free mineral stream and a highly concentrated carbon product. The method involves mixing the fly ash comprised of carbon and inorganic mineral matter with a liquid hydrocarbon to form a slurry, contacting the slurry with an aqueous solution, dispersing the hydrocarbon slurry into small droplets within the aqueous solution by mechanical mixing and/or aeration, concentrating the inorganic mineral matter in the aqueous solution, agglomerating the carbon and hydrocarbon in the form of droplets, collecting the droplets, separating the hydrocarbon from the concentrated carbon product, and recycling the hydrocarbon.

  7. Sample preparation methods for determination of drugs of abuse in hair samples: A review.

    PubMed

    Vogliardi, Susanna; Tucci, Marianna; Stocchero, Giulia; Ferrara, Santo Davide; Favretto, Donata

    2015-02-01

    Hair analysis has assumed increasing importance in the determination of substances of abuse, both in clinical and forensic toxicology investigations. Hair analysis offers particular advantages over other biological matrices (blood and urine), including a larger window of detection, ease of collection and sample stability. In the present work, an overview of sample preparation techniques for the determination of substances of abuse in hair is provided, specifically regarding the principal steps in hair sample treatment-decontamination, extraction and purification. For this purpose, a survey of publications found in the MEDLINE database from 2000 to date was conducted. The most widely consumed substances of abuse and psychotropic drugs were considered. Trends in simplification of hair sample preparation, washing procedures and cleanup methods are discussed. Alternative sample extraction techniques, such as head-space solid phase microextraction (HS-SPDE), supercritical fluid extraction (SFE) and molecularly imprinted polymers (MIP) are also reported. PMID:25604816

  8. 77 FR 55832 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of a New Equivalent Method

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-11

    ... made under the provisions of 40 CFR part 53, as ] amended on August 31, 2011 (76 FR 54326-54341). The... AGENCY Ambient Air Monitoring Reference and Equivalent Methods: Designation of a New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of a new equivalent method...

  9. 77 FR 60985 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-05

    ... 53, as amended on August 31, 2011 (76 FR 54326-54341). The new equivalent methods are automated... AGENCY Ambient Air Monitoring Reference and Equivalent Methods: Designation of Three New Equivalent Methods AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of three new...

  10. Occupational dimethylformamide exposure. 1. Diffusive sampling of dimethylformamide vapor for determination of time-weighted average concentration in air.

    PubMed

    Yasugi, T; Kawai, T; Mizunuma, K; Horiguchi, S; Iguchi, H; Ikeda, M

    1992-01-01

    A diffusive sampling method with water as absorbent was examined in comparison with 3 conventional methods of diffusive sampling with carbon cloth as absorbent, pumping through National Institute of Occupational Safety and Health (NIOSH) charcoal tubes, and pumping through NIOSH silica gel tubes to measure time-weighted average concentration of dimethylformamide (DMF). DMF vapors of constant concentrations at 3-110 ppm were generated by bubbling air at constant velocities through liquid DMF followed by dilution with fresh air. Both types of diffusive samplers could either absorb or adsorb DMF in proportion to time (0.25-8 h) and concentration (3-58 ppm), except that the DMF adsorbed was below the measurable amount when carbon cloth samplers were exposed at 3 ppm for less than 1 h. When both diffusive samplers were loaded with DMF and kept in fresh air, the DMF in water samplers stayed unchanged for at least for 12 h. The DMF in carbon cloth samplers showed a decay with a half-time of 14.3 h. When the carbon cloth was taken out immediately after termination of DMF exposure, wrapped in aluminum foil, and kept refrigerated, however, there was no measurable decrease in DMF for at least 3 weeks. When the air was drawn at 0.2 l/min, a breakthrough of the silica gel tube took place at about 4,000 ppm.min (as the lower 95% confidence limit), whereas charcoal tubes could tolerate even heavier exposures, suggesting that both tubes are fit to measure the 8-h time-weighted average of DMF at 10 ppm. PMID:1577523

  11. Simulating and explaining passive air sampling rates for semi-volatile compounds on polyurethane foam passive samplers

    PubMed Central

    Petrich, Nicholas T.; Spak, Scott N.; Carmichael, Gregory R.; Hu, Dingfei; Martinez, Andres; Hornbuckle, Keri C.

    2013-01-01

    Passive air samplers (PAS) including polyurethane foam (PUF) are widely deployed as an inexpensive and practical way to sample semi-volatile pollutants. However, concentration estimates from PAS rely on constant empirical mass transfer rates, which add unquantified uncertainties to concentrations. Here we present a method for modeling hourly sampling rates for semi-volatile compounds from hourly meteorology using first-principle chemistry, physics, and fluid dynamics, calibrated from depuration experiments. This approach quantifies and explains observed effects of meteorology on variability in compound-specific sampling rates and analyte concentrations; simulates nonlinear PUF uptake; and recovers synthetic hourly concentrations at a reference temperature. Sampling rates are evaluated for polychlorinated biphenyl congeners at a network of Harner model samplers in Chicago, Illinois during 2008, finding simulated average sampling rates within analytical uncertainty of those determined from loss of depuration compounds, and confirming quasi-linear uptake. Results indicate hourly, daily and interannual variability in sampling rates, sensitivity to temporal resolution in meteorology, and predictable volatility-based relationships between congeners. We quantify importance of each simulated process to sampling rates and mass transfer and assess uncertainty contributed by advection, molecular diffusion, volatilization, and flow regime within the PAS, finding PAS chamber temperature contributes the greatest variability to total process uncertainty (7.3%). PMID:23837599

  12. Method to characterize collective impact of factors on indoor air

    NASA Astrophysics Data System (ADS)

    Szczurek, Andrzej; Maciejewska, Monika; Teuerle, Marek; Wyłomańska, Agnieszka

    2015-02-01

    One of the most important problems in studies of building environment is a description of how it is influenced by various dynamically changing factors. In this paper we characterized the joint impact of a collection of factors on indoor air quality (IAQ). We assumed that the influence is reflected in the temporal variability of IAQ parameters and may be deduced from it. The proposed method utilizes mean square displacement (MSD) analysis which was originally developed for studying the dynamics in various systems. Based on the MSD time-dependence descriptor β, we distinguished three types of the collective impact of factors on IAQ: retarding, stabilizing and promoting. We presented how the aggregated factors influence the temperature, relative humidity and CO2 concentration, as these parameters are informative for the condition of indoor air. We discovered, that during a model day there are encountered one, two or even three types of influence. The presented method allows us to study the impacts from the perspective of the dynamics of indoor air.

  13. Sampling artifacts in active air sampling of semivolatile organic contaminants: Comparing theoretical and measured artifacts and evaluating implications for monitoring networks.

    PubMed

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Klánová, Jana

    2016-10-01

    The effects of sampling artifacts are often not fully considered in the design of air monitoring with active air samplers. Semivolatile organic contaminants (SVOCs) are particularly vulnerable to a range of sampling artifacts because of their wide range of gas-particle partitioning and degradation rates, and these can lead to erroneous measurements of air concentrations and a lack of comparability between sites with different environmental and sampling conditions. This study used specially adapted filter-sorbent sampling trains in three types of active air samplers to investigate breakthrough of SVOCs, and the possibility of other sampling artifacts. Breakthrough volumes were experimentally determined for a range of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in sampling volumes from 300 to 10,000 m(3), and sampling durations of 1-7 days. In parallel, breakthrough was estimated based on theoretical sorbent-vapor pressure relationships. The comparison of measured and theoretical determinations of breakthrough demonstrated good agreement between experimental and estimated breakthrough volumes, and showed that theoretical breakthrough estimates should be used when developing air monitoring protocols. Significant breakthrough in active air samplers occurred for compounds with vapor pressure >0.5 Pa at volumes <700 m(3). Sample volumes between 700 and 10,000 m(3) may lead to breakthrough for compounds with vapor pressures between 0.005 and 0.5 Pa. Breakthrough is largely driven by sample volume and compound volatility (therefore indirectly by temperature) and is independent of sampler type. The presence of significant breakthrough at "typical" sampling conditions is relevant for air monitoring networks, and may lead to under-reporting of more volatile SVOCs. PMID:26743995

  14. Examination of Hydrate Formation Methods: Trying to Create Representative Samples

    SciTech Connect

    Kneafsey, T.J.; Rees, E.V.L.; Nakagawa, S.; Kwon, T.-H.

    2011-04-01

    Forming representative gas hydrate-bearing laboratory samples is important so that the properties of these materials may be measured, while controlling the composition and other variables. Natural samples are rare, and have often experienced pressure and temperature changes that may affect the property to be measured [Waite et al., 2008]. Forming methane hydrate samples in the laboratory has been done a number of ways, each having advantages and disadvantages. The ice-to-hydrate method [Stern et al., 1996], contacts melting ice with methane at the appropriate pressure to form hydrate. The hydrate can then be crushed and mixed with mineral grains under controlled conditions, and then compacted to create laboratory samples of methane hydrate in a mineral medium. The hydrate in these samples will be part of the load-bearing frame of the medium. In the excess gas method [Handa and Stupin, 1992], water is distributed throughout a mineral medium (e.g. packed moist sand, drained sand, moistened silica gel, other porous media) and the mixture is brought to hydrate-stable conditions (chilled and pressurized with gas), allowing hydrate to form. This method typically produces grain-cementing hydrate from pendular water in sand [Waite et al., 2004]. In the dissolved gas method [Tohidi et al., 2002], water with sufficient dissolved guest molecules is brought to hydrate-stable conditions where hydrate forms. In the laboratory, this is can be done by pre-dissolving the gas of interest in water and then introducing it to the sample under the appropriate conditions. With this method, it is easier to form hydrate from more soluble gases such as carbon dioxide. It is thought that this method more closely simulates the way most natural gas hydrate has formed. Laboratory implementation, however, is difficult, and sample formation is prohibitively time consuming [Minagawa et al., 2005; Spangenberg and Kulenkampff, 2005]. In another version of this technique, a specified quantity of gas

  15. Nonuniform air flow in inlets: the effect on filter deposits in the fiber sampling cassette.

    PubMed

    Baron, P A; Chen, C C; Hemenway, D R; O'Shaughnessy, P

    1994-08-01

    Smoke stream studies were combined with a new technique for visualizing a filter deposit from samples used to monitor asbestos or other fibers. Results clearly show the effect of secondary flow vortices within the sampler under anisoaxial sampling conditions. The vortices observed at low wind velocities occur when the inlet axis is situated at angles between 45 degrees and 180 degrees to the motion of the surrounding air. It is demonstrated that the vortices can create a complex nonuniform pattern in the filter deposit, especially when combined with particle settling or electrostatic interactions between the particles and the sampler. Inertial effects also may play a role in the deposit nonuniformity, as well as causing deposition on the cowl surfaces. Changes in the sampler, such as its placement, may reduce these biases. The effects noted are not likely to occur in all sampling situations, but may explain some reports of high variability on asbestos fiber filter samples. The flow patterns observed in this study are applicable to straight, thin-walled inlets. Although only compact particles were used, the air flow patterns and forces involved will have similar effects on fibers of the same aerodynamic diameter. PMID:7942509

  16. Greenhouse gas analysis of air samples collected onboard the CARIBIC passenger aircraft

    NASA Astrophysics Data System (ADS)

    Schuck, T. J.; Brenninkmeijer, C. A. M.; Slemr, F.; Xueref-Remy, I.; Zahn, A.

    2009-03-01

    CARIBIC (Civil Aircraft for the Regular Investigation of the Atmosphere Based on an Instrument Container) is a long-term atmospheric measurement program based on the use of a comprehensive scientific instrument package aboard a passenger aircraft. In addition to real time measurements, whole air sampling is performed regularly at cruising altitude in the upper troposphere and the extra-tropical UT/LS region. Air samples are analysed for greenhouse gases, NMHCs, halocarbons, and isotopic composition. The routinely performed greenhouse gas analysis comprises gas chromatography measurements of CO2, CH4, N2O and SF6. The sampling procedure, the GC system used for greenhouse gas analysis and its performance are described. Comparisons with other laboratories have shown good agreement of results as has a comparison with results from a CO2 in-situ analyser that is also part of the CARIBIC instrumentation. The timeseries of CO2 obtained from the collection of 684 samples at latitudes between 30° N and 56° N on 21 roundtrips out of Germany to different destinations in Asia between November 2005 and October 2008 is shown. A timeshift in the seasonal cyle of about one month was observed between the upper troposphere and the tropopause region. For two sets of return flights from Germany to the Philippines the relations between the four greenhouse gases CO2, CH4, N2O and SF6 are discussed in more detail. Distinct seasonal changes in the correlation between CH4 and CO2 are observed.

  17. Characterizing lentic freshwater fish assemblages using multiple sampling methods

    USGS Publications Warehouse

    Fischer, Jesse R.; Quist, Michael

    2014-01-01

    Characterizing fish assemblages in lentic ecosystems is difficult, and multiple sampling methods are almost always necessary to gain reliable estimates of indices such as species richness. However, most research focused on lentic fish sampling methodology has targeted recreationally important species, and little to no information is available regarding the influence of multiple methods and timing (i.e., temporal variation) on characterizing entire fish assemblages. Therefore, six lakes and impoundments (48–1,557 ha surface area) were sampled seasonally with seven gear types to evaluate the combined influence of sampling methods and timing on the number of species and individuals sampled. Probabilities of detection for species indicated strong selectivities and seasonal trends that provide guidance on optimal seasons to use gears when targeting multiple species. The evaluation of species richness and number of individuals sampled using multiple gear combinations demonstrated that appreciable benefits over relatively few gears (e.g., to four) used in optimal seasons were not present. Specifically, over 90 % of the species encountered with all gear types and season combinations (N = 19) from six lakes and reservoirs were sampled with nighttime boat electrofishing in the fall and benthic trawling, modified-fyke, and mini-fyke netting during the summer. Our results indicated that the characterization of lentic fish assemblages was highly influenced by the selection of sampling gears and seasons, but did not appear to be influenced by waterbody type (i.e., natural lake, impoundment). The standardization of data collected with multiple methods and seasons to account for bias is imperative to monitoring of lentic ecosystems and will provide researchers with increased reliability in their interpretations and decisions made using information on lentic fish assemblages.

  18. Urban air quality assessment using monitoring data of fractionized aerosol samples, chemometrics and meteorological conditions.

    PubMed

    Yotova, Galina I; Tsitouridou, Roxani; Tsakovski, Stefan L; Simeonov, Vasil D

    2016-01-01

    The present article deals with assessment of urban air by using monitoring data for 10 different aerosol fractions (0.015-16 μm) collected at a typical urban site in City of Thessaloniki, Greece. The data set was subject to multivariate statistical analysis (cluster analysis and principal components analysis) and, additionally, to HYSPLIT back trajectory modeling in order to assess in a better way the impact of the weather conditions on the pollution sources identified. A specific element of the study is the effort to clarify the role of outliers in the data set. The reason for the appearance of outliers is strongly related to the atmospheric condition on the particular sampling days leading to enhanced concentration of pollutants (secondary emissions, sea sprays, road and soil dust, combustion processes) especially for ultra fine and coarse particles. It is also shown that three major sources affect the urban air quality of the location studied-sea sprays, mineral dust and anthropogenic influences (agricultural activity, combustion processes, and industrial sources). The level of impact is related to certain extent to the aerosol fraction size. The assessment of the meteorological conditions leads to defining of four downwind patterns affecting the air quality (Pelagic, Western and Central Europe, Eastern and Northeastern Europe and Africa and Southern Europe). Thus, the present study offers a complete urban air assessment taking into account the weather conditions, pollution sources and aerosol fractioning. PMID:26942452

  19. An economic passive sampling method to detect particulate pollutants using magnetic measurements.

    PubMed

    Cao, Liwan; Appel, Erwin; Hu, Shouyun; Ma, Mingming

    2015-10-01

    Identifying particulate matter (PM) emitted from industrial processes into the atmosphere is an important issue in environmental research. This paper presents a passive sampling method using simple artificial samplers that maintains the advantage of bio-monitoring, but overcomes some of its disadvantages. The samplers were tested in a heavily polluted area (Linfen, China) and compared to results from leaf samples. Spatial variations of magnetic susceptibility from artificial passive samplers and leaf samples show very similar patterns. Scanning electron microscopy suggests that the collected PM are mostly in the range of 2-25 μm; frequent occurrence of spherical shape indicates industrial combustion dominates PM emission. Magnetic properties around power plants show different features than other plants. This sampling method provides a suitable and economic tool for semi-quantifying temporal and spatial distribution of air quality; they can be installed in a regular grid and calibrate the weight of PM. PMID:26026265

  20. Comparison of pigment content of paint samples using spectrometric methods

    NASA Astrophysics Data System (ADS)

    Trzcińska, Beata; Kowalski, Rafał; Zięba-Palus, Janina

    2014-09-01

    The aim of the paper was to evaluate the influence of pigment concentration and its distribution in polymer binder on the possibility of colour identification and paint sample comparison. Two sets of paint samples: one containing red and another one green pigment were prepared. Each set consisted of 13 samples differing gradually in the concentration of pigment. To obtain the sets of various colour shades white paint was mixed with the appropriate pigment in the form of a concentrated suspension. After solvents evaporation the samples were examined using spectrometric methods. The resin and main filler were identified by IR method. Colour and white pigments were identified on the base of Raman spectra. Colour of samples were compared based on Vis spectrometry according to colour theory. It was found that samples are homogenous (parameter measuring colour similarity ΔE < 3). The values of ΔE between the neighbouring samples in the set revealed decreasing linear function and between the first and following one - a logarithmic function.

  1. Off-axis angular spectrum method with variable sampling interval

    NASA Astrophysics Data System (ADS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Pi, Jae-Eun; Choi, Ji-Hun; Kim, Gi Heon; Lee, Myung-Lae; Ryu, Hojun; Hwang, Chi-Sun

    2015-08-01

    We proposed a novel off-axis angular spectrum method (ASM) for simulating free space wave propagation with a large shifted destination plane. The off-axis numerical simulation took wave propagation between a parallel source and a destination plane, but a destination plane was shifted from a source plane. The shifted angular spectrum method was proposed for diffraction simulation with a shifted destination plane and satisfied the Nyquist condition for sampling by limiting a bandwidth of a propagation field to avoid an aliasing error due to under sampling. However, the effective sampling number of the shifted ASM decreased when the shifted distance of the destination plane was large which caused a numerical error in the diffraction simulation. To compensate for the decrease of an effective sampling number for the large shifted destination plane, we used a variable sampling interval in a Fourier space to maintain the same effective sampling number independent of the shifted distance of the destination plane. As a result, our proposed off-axis ASM with a variable sampling interval can produce simulation results with high accuracy for nearly every shifted distance of a destination plane when an off-axis angle is less than 75°. We compared the performances of the off-axis ASM using the Chirp Z transform and non-uniform FFT for implementing a variable spatial frequency in a Fourier space.

  2. RAPID METHOD FOR DETERMINATION OF RADIOSTRONTIUM IN EMERGENCY MILK SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-07-17

    A new rapid separation method for radiostrontium in emergency milk samples was developed at the Savannah River Site (SRS) Environmental Bioassay Laboratory (Aiken, SC, USA) that will allow rapid separation and measurement of Sr-90 within 8 hours. The new method uses calcium phosphate precipitation, nitric acid dissolution of the precipitate to coagulate residual fat/proteins and a rapid strontium separation using Sr Resin (Eichrom Technologies, Darien, IL, USA) with vacuum-assisted flow rates. The method is much faster than previous method that use calcination or cation exchange pretreatment, has excellent chemical recovery, and effectively removes beta interferences. When a 100 ml sample aliquot is used, the method has a detection limit of 0.5 Bq/L, well below generic emergency action levels.

  3. Pattern recognition methods and air pollution source identification. [based on wind direction

    NASA Technical Reports Server (NTRS)

    Leibecki, H. F.; King, R. B.

    1978-01-01

    Directional air samplers, used for resolving suspended particulate matter on the basis of time and wind direction were used to assess the feasibility of characterizing and identifying emission source types in urban multisource environments. Filters were evaluated for 16 elements and X-ray fluorescence methods yielded elemental concentrations for direction, day, and the interaction of direction and day. Large numbers of samples are necessary to compensate for large day-to-day variations caused by wind perturbations and/or source changes.

  4. Quantifying water and air redistribution in heterogeneous sand sample by neutron imaging

    NASA Astrophysics Data System (ADS)

    Šácha, Jan; Sobotková, Martina; Jelínková, Vladimíra; Sněhota, Michal; Vontobel, Peter; Hovind, Jan

    2014-05-01

    Significant temporal variation of quasi saturated hydraulic conductivity (Kqs) has been observed to date in number of infiltration experiments conducted mainly on heterogeneous soil of Cambisol. The change of quasi-saturated hydraulic conductivity cannot be precisely described by existing models. The Kqs variations has been recently attributed to a changing distribution of the entrapped air and water within the sample. It is expected that air is moved to the preferential pathway and acts as a barrier there. To support this assumption a ponded infiltration experiment was conducted on a soil sample packed into the quartz glass column of inner diameter of 34 mm. The sample composition represents simplified heterogeneity of the natural soil but also allow the easy quantitative water content determination in individual subdomains of the sample. The matrix formed by a fine sand was surrounded with regions of coarse sand representing preferential flow pathways. The Kqs was determined from the known hydraulic gradient and measured volume flux. The experiment was monitored by neutron radiography. Volume of water in the sample calculated from neutron projections matched very well with actually infiltrated volume in the sample during first 40 second after beginning of infiltration. From the acquired radiographic images the 3D tomography images were reconstructed to obtain the spatial distribution of the water content within the sample. Difference between water volume calculated from radiography and tomography images was no more than 5%. While the total amount of water determined by NR within the sample during the quasi steady state flow remains practically constant (27.9 cm3 at the beginning and 28.6 cm3 on the end of infiltration) the water content in the coarse fraction decreases (from 0.333 to 0.324) and the water content in the fine fraction increases (from 0.414 to 0.436) in 5 hours. Similarly to previous experiments performed on natural Cambisols, the results support

  5. [Progress in sample preparation and analytical methods for trace polar small molecules in complex samples].

    PubMed

    Zhang, Qianchun; Luo, Xialin; Li, Gongke; Xiao, Xiaohua

    2015-09-01

    Small polar molecules such as nucleosides, amines, amino acids are important analytes in biological, food, environmental, and other fields. It is necessary to develop efficient sample preparation and sensitive analytical methods for rapid analysis of these polar small molecules in complex matrices. Some typical materials in sample preparation, including silica, polymer, carbon, boric acid and so on, are introduced in this paper. Meanwhile, the applications and developments of analytical methods of polar small molecules, such as reversed-phase liquid chromatography, hydrophilic interaction chromatography, etc., are also reviewed. PMID:26753274

  6. Glyphosate–rich air samples induce IL–33, TSLP and generate IL–13 dependent airway inflammation

    PubMed Central

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M.; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A.; Adhikari, Atin

    2014-01-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4−/−, and IL-13−/− mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease. PMID:25172162

  7. The contribution of nitro- and methylnitronaphthalenes to the vapor-phase mutagenicity of ambient air samples

    NASA Astrophysics Data System (ADS)

    Gupta, Pamela; Harger, William P.; Arey, Janet

    1- and 2-Nitronaphthalene (NN) and the 14 methylnitronaphthalene (MNN) isomers were identified and quantified in ambient vapor-phase samples collected in Redlands, CA during moderate photochemical air pollution. The mutagenic activities of NN and MNN standards were determined using a microsuspension-preincubation modification of the Ames Salmonella bacterial reversion assay in strain TA98 without microsomal activation. The calculated contributions of the NNs and MNNs to the total vapor-phase ambient mutagenic activity were ˜ 18 and ˜ 32% for daytime and nighttime composite samples, respectively. Enhanced mutagenic activity in the nighttime sample was attributed to NN and MNN formation from nighttime N03 radical-initiated reactions of naphthalene and the methylnaphthalenes.

  8. Atmospheric trace gas measurements with a new clean air sampling system

    SciTech Connect

    Leifer, R.; Sommers, K.; Guggenheim, S.F.

    1981-10-01

    The development of a new clean air sampling system for the Department of Energy's WB-57F aircraft has allowed the analysis of CCl/sub 3/F (Fluorocarbon-11), CCl/sub 2/F/sub 2/ (Fluorocarbon-12), CHClF/sub 2/ (Fluorocarbon-22), C/sub 2/Cl/sub 3/F/sub 3/ (Fluorocarbon-113), CH/sub 4/, CO, CO/sub 2/, N/sub 2/O, CH/sub 3/Cl, CCl/sub 4/, CH/sub 3/CCl/sub 3/, OCS and SF/sub 6/ in tropospheric and stratospheric samples. Samples collected during the interception of the plume from the eruption of Mount St. Helens indicate that OCS was injected into the stratosphere during the eruption. A large CO/sub 2/ gradient was found at 19.2 km on this flight.

  9. Evaluation of Stress Loaded Steel Samples Using Selected Electromagnetic Methods

    SciTech Connect

    Chady, T.

    2004-02-26

    In this paper the magnetic leakage flux and eddy current method were used to evaluate changes of materials' properties caused by stress. Seven samples made of ferromagnetic material with different level of applied stress were prepared. First, the leakage magnetic fields were measured by scanning the surface of the specimens with GMR gradiometer. Next, the same samples were evaluated using an eddy current sensor. A comparison between results obtained from both methods was carried out. Finally, selected parameters of the measured signal were calculated and utilized to evaluate level of the applied stress. A strong coincidence between amount of the applied stress and the maximum amplitude of the derivative was confirmed.

  10. On the Exploitation of Sensitivity Derivatives for Improving Sampling Methods

    NASA Technical Reports Server (NTRS)

    Cao, Yanzhao; Hussaini, M. Yousuff; Zang, Thomas A.

    2003-01-01

    Many application codes, such as finite-element structural analyses and computational fluid dynamics codes, are capable of producing many sensitivity derivatives at a small fraction of the cost of the underlying analysis. This paper describes a simple variance reduction method that exploits such inexpensive sensitivity derivatives to increase the accuracy of sampling methods. Three examples, including a finite-element structural analysis of an aircraft wing, are provided that illustrate an order of magnitude improvement in accuracy for both Monte Carlo and stratified sampling schemes.

  11. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    SciTech Connect

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides and strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.

  12. Polybrominated diphenyl ethers and alternative flame retardants in air and precipitation samples from the northern Lake Victoria region, East Africa.

    PubMed

    Arinaitwe, Kenneth; Muir, Derek C G; Kiremire, Bernard T; Fellin, Phil; Li, Henrik; Teixeira, Camilla

    2014-01-01

    High volume air and precipitation samples were collected close to the shore of Lake Victoria at Entebbe, Uganda, between October 2008 and July 2010 inclusive. Polybrominated diphenyl ethers (PBDEs) and alternative flame retardants (AFRs) were analyzed by GC-MS. BDEs 47, 99, and 209 were the predominant PBDEs with mean concentrations (in air) of 9.84, 4.38, 8.27 pg m(-3) and mean fluxes in precipitation of 3.40, 6.23, and 7.82 ng m(-2) sample(-1), respectively. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), and hexabromocyclododecane (HBCDD), anti- and syn-Dechlorane plus were detected at levels comparable with those of PBDEs. Both PBDEs and AFRs in air generally increased from 2008 to 2010. Elevated PBDE concentrations in air were associated with slow moving low altitude air masses from the region immediately adjacent to the lake, while low concentrations were mostly associated with fast moving westerly and southwesterly air masses. Analysis of the octa- and nona-BDE profiles suggested photolysis and pyrolytic debromination of BDE-209 in the air samples. The highly halogenated and most abundant PBDEs and AFRs in air also predominated in precipitation samples. This is the first study to report flame retardants in high volume air samples and precipitation in Equatorial Africa. PMID:24400732

  13. Development and validation of a heated canister-based source sampling method

    SciTech Connect

    Crawford, R.J.; Elam, D.L.

    1994-12-31

    In response to the Clean Air Act Amendments of 1990, the US pulp and paper industry through the American Forest and Paper Association (AF and PA) has instituted a program to characterize hazardous air pollutant (HAP) emissions from a variety of sources at 16 facilities. To meet some of the specific needs of this program, a method has been developed, based on EPA Method 18, that uses a heated sampling system to transfer source gas samples to a heated stainless steel summa polished canister. After sampling, the canister is kept hot in an insulated box and transferred to an on-site mobile laboratory. All of the analyte system components are also heated so that the moisture is not allowed to condense in the sample before it is analyzed. An initial mill screening study, laboratory evaluation/ validation, and an EPA Method 301 validation on pulp mill sources have all been completed with acceptable results. This method is being used to quantitate 26 VOCs, e.g., methanol, acetone, methylene chloride, chloroform, benzene, methyl ethyl ketone, and methyl isobutyl ketone.

  14. Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

  15. RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-08-27

    The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared to NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.

  16. An experiment to determine atmospheric CO concentrations of tropical South Atlantic air samples

    NASA Astrophysics Data System (ADS)

    Kirchhoff, V. W. J. H.; Aires, C. B.; Alvala, P. C.

    2003-04-01

    New observations of atmospheric carbon monoxide, CO, are described, from tropical South Atlantic air samples. A new observational site, Maxaranguape, was set up in a clean remote environment right next to the ocean on the north-east coast of Brazil, to obtain CO mixing ratios and auxiliary data (meteorological parameters, ozone (O3), carbon dioxide (CO2) and methane (CH4)) during three sequential seasonal cycles. The seasonal variations of temperature, humidity and precipitation are shown for the new site. Chromatographic separation followed by mercury oxide detection is used to measure CO. The seasonality of the CO data was clearly established. Minima are seen during April, May and June showing wet-period averages of 56.1 parts per billion by volume (ppbv), with standard deviation 8.7 ppbv; during dry-period months, August to November, the average was 77.7 ± 16.5 ppbv. For comparison, CO concentrations were also measured over continental areas in Brazil. Much larger values have been found in moderate 'burning' regions, such as the south of the state of Mato Grosso and the north-western part of the state of Parana, where 200 ppbv in the dry season has been observed. Since normally the air masses have travelled for several days over the ocean, the air masses over the site present low chemical activity. Daily variations of CO2 are very small, of the order of a few percent relative to the diurnal mean. Only on rare occasions, when the wind direction changes, is the sampled air contaminated from flowing over the inhabited shoreline to the south, and then CO2 varies inversely with O3. The monthly mean CH4 data does not show a clear seasonal variation, possibly because the amplitude of the CH4 variation is only of the order of 1%, which is close to the precision of the measuring instrument.

  17. Comparative analysis of ACTH and corticosterone sampling methods in rats.

    PubMed

    Vahl, Torsten P; Ulrich-Lai, Yvonne M; Ostrander, Michelle M; Dolgas, C Mark; Elfers, Eileen E; Seeley, Randy J; D'Alessio, David A; Herman, James P

    2005-11-01

    A frequently debated question for studies involving the measurement of stress hormones in rodents is the optimal method for collecting blood with minimal stress to the animal. Some investigators prefer the implantation of indwelling catheters to allow for frequent sampling. Others argue that the implantation of a catheter creates a chronic stress to the animal that confounds stress hormone measures and therefore rely on tail vein sampling. Moreover, some investigators measure hormones in trunk blood samples obtained after anesthesia, a practice that may itself raise hormone levels. To address these controversies, we 1) compared plasma ACTH and corticosterone (Cort) concentrations in pre- and poststress rat blood samples obtained via previously implanted vena cava catheters, tail vein nicks, or clipping the tip off the tail and 2) compared plasma ACTH and Cort in rat blood samples obtained by decapitation with and without anesthesia. Rats sampled via indwelling catheters displayed lower prestress ACTH levels than those sampled by tail vein nick if the time to acquire samples was not limited; however, elevated basal ACTH was not observed in samples obtained by tail clip or tail nick when the samples were obtained within 3 min. Baseline Cort levels were similar in all groups. After restraint stress, the profile of the plasma ACTH and Cort responses was not affected by sampling method. Decapitation with prior administration of CO2 or pentobarbital sodium increased plasma ACTH levels approximately 13- and 2-fold, respectively, when compared with decapitation without anesthesia. These data indicate that tail vein nicking, tail clipping, or indwelling venous catheters can be used for obtaining plasma for ACTH and Cort during acute stress studies without confounding the measurements. However, the elevation in basal ACTH seen in the tail vein nick group at baseline suggests that sampling needs to be completed rapidly (<3 min) to avoid the initiation of the pituitary stress

  18. Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters

    PubMed Central

    Calfee, M. Worth; Rose, Laura J.; Tufts, Jenia; Morse, Stephen; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2016-01-01

    The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37 mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50% of their total holding capacity. The results were analyzed by one-way ANOVA across material types, presence or absence of dust, and sampling device. The extraction method gave higher relative recoveries than the two vacuum methods evaluated (p ≤ 0.001). On average, recoveries obtained by the vacuum methods were about 30% of those achieved by the extraction method. Relative recoveries between the two vacuum methods were not significantly different (p > 0.05). Although extraction methods yielded higher recoveries than vacuum methods, either HVAC filter sampling approach may provide a rapid and inexpensive mechanism for understanding the extent of contamination following a wide-area biological release incident. PMID:24184312

  19. Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters.

    PubMed

    Calfee, M Worth; Rose, Laura J; Tufts, Jenia; Morse, Stephen; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2014-01-01

    The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50% of their total holding capacity. The results were analyzed by one-way ANOVA across material types, presence or absence of dust, and sampling device. The extraction method gave higher relative recoveries than the two vacuum methods evaluated (p≤0.001). On average, recoveries obtained by the vacuum methods were about 30% of those achieved by the extraction method. Relative recoveries between the two vacuum methods were not significantly different (p>0.05). Although extraction methods yielded higher recoveries than vacuum methods, either HVAC filter sampling approach may provide a rapid and inexpensive mechanism for understanding the extent of contamination following a wide-area biological release incident. PMID:24184312

  20. Performance Prediction Method of CO2 Cycle for Air Cooling

    NASA Astrophysics Data System (ADS)

    Koyama, Shigeru; Xue, Jun; Kuwahara, Ken

    From the perspective of global environmental protection and energy-saving, the research and development on high-efficiency heat pump and refrigeration systems using environment-friendly refrigerants have become one of the most important issues in the air-conditioning and refrigeration sector. In the present work, a steady-state model of the CO2 transcritical cycle for air cooling, which consists of a rotary compressor, a fin-tube gas cooler,a fin-tube evaporator and an expansion valve, has been developed. The detailed model of fin-tube heat exchanger has been constructed by means of the finite volume method, in which the local heat transfer and flow characteristics are evaluated. It should be noted that the effects of the dew condensation generated on the cooling surface are considered in the evaporator model. As a calculation example, the effects of the indoor air wet-bulb temperature on the cycle performance have been examined with this developed simulator.

  1. Spectrum recovery method analysis on nonuniform sampling interference data

    NASA Astrophysics Data System (ADS)

    Huang, Fengzhen; Li, Jingzhen; Cao, Jun

    2015-02-01

    Temporally and Spatially Modulated Fourier Transform Imaging Spectrometer (TSMFTIS) is a new imaging spectrometer without moving mirrors and slits. The interferogram of the target point can be consisted by sequentially arranging the interference information extracted from the same target point of the sequential images, and the spectrum can be recovered by using fast Fourier transform. In the practical application, there is nonuniform sampling in the interference data, and many researchers have carried out researches on nonuniform sampling with the fast Fourier transform algorithm. As to the issue of interference data in the nonuniform sampling, the nonuniform sampling degree's impact on the recovered spectrum precision is currently and mainly analyzed. This paper has adapted several typical nonuniform fast Fourier transform (NUFFT) methods, carried out spectrum recovery precision comparison on the interferogram of the nonuniform sampling point with the above methods, and further analyzed the impact of kernel function type, oversampling ratio and kernel function width's on spectrum recovery precision in the above mentioned methods. The experiment result indicates that, when the oversampling ratio is 4 and the kernel function width is 4, the spectrum recovery precision with NUFFT based on Blackman type kernel function is optimal, however, the Gaussian kernel function is stable.

  2. Global metabolite analysis of yeast: evaluation of sample preparation methods.

    PubMed

    Villas-Bôas, Silas G; Højer-Pedersen, Jesper; Akesson, Mats; Smedsgaard, Jørn; Nielsen, Jens

    2005-10-30

    Sample preparation is considered one of the limiting steps in microbial metabolome analysis. Eukaryotes and prokaryotes behave very differently during the several steps of classical sample preparation methods for analysis of metabolites. Even within the eukaryote kingdom there is a vast diversity of cell structures that make it imprudent to blindly adopt protocols that were designed for a specific group of microorganisms. We have therefore reviewed and evaluated the whole sample preparation procedures for analysis of yeast metabolites. Our focus has been on the current needs in metabolome analysis, which is the analysis of a large number of metabolites with very diverse chemical and physical properties. This work reports the leakage of intracellular metabolites observed during quenching yeast cells with cold methanol solution, the efficacy of six different methods for the extraction of intracellular metabolites, and the losses noticed during sample concentration by lyophilization and solvent evaporation. A more reliable procedure is suggested for quenching yeast cells with cold methanol solution, followed by extraction of intracellular metabolites by pure methanol. The method can be combined with reduced pressure solvent evaporation and therefore represents an attractive sample preparation procedure for high-throughput metabolome analysis of yeasts. PMID:16240456

  3. Passive air sampling of organochlorine pesticides, polychlorinated biphenyls, and polybrominated diphenyl ethers across the tibetan plateau.

    PubMed

    Wang, Xiao-Ping; Gong, Ping; Yao, Tan-Dong; Jones, Kevin C

    2010-04-15

    So far there are limited data on persistent organic pollutants (POPs) in the atmosphere of the Tibetan Plateau. XAD 2-resin based passive air samplers were therefore deployed for 1 year (between July 2007-June 2008) at 16 locations across the Tibetan Plateau. Based on previously reported sampling rates (R) derived in the north and south America, and their correlations with atmospheric temperature and pressure, R values in the present study were in the range of 2.2-3.3 m(3) d(-1) (average = 2.7 +/- 0.3). Derived air concentrations (pg/m(3)) ranged as follows: DDTs, 5-75; HCHs, 0.1-36; alpha-endosulfan, 0.1-10; HCB, 2.8-80; sum of 15 PCBs, 1.8-8.2; and sum of 9 PBDEs, 0.1-8.3. The highest DDTs occurred at Qamdo, where the sampling site is near to farm land, indicating the spatial distribution of DDTs across the plateau may be influenced by scattered local usage of DDT. Higher levels of HCHs were observed at sites with high elevation (>4000 m) and close to the China-India border, indicating possible long-range atmospheric transport. The highest levels of HCB, PCBs, and PBDEs were found at a site impacted by forest fire during the sampling campaign. PMID:20235613

  4. Air-Assisted Liquid Liquid-Microextraction for the Analysis of Fungicides from Environmental Water and Juice Samples.

    PubMed

    Wu, Shiju; Jin, Tingting; Cheng, Jing; Zhou, Hongbin; Cheng, Min

    2015-07-01

    In this work, a rapid method based on air-assisted liquid liquid microextraction (AALLME) was developed for the determination of three fungicides (azoxystrobin, diethofencarb and pyrimethanil) in water and juice samples. A narrow-neck glass tube was made to facilitate collection of the low-density extractant. The mixture of extractant and sample solution is rapidly sucked into a 5-mL glass syringe and then is injected into the narrow-neck glass tube and the procedure is repeated six times. A homogeneous solution was formed and then with the continuous injection of air by a 20-mL glass syringe, phase separation happened and the extractant was collected on the top of the sample solution. No centrifugation separation step was involved. It took only 90 s to complete the pretreatment process. The influence of main factors on the extraction efficiency is studied. Under optimal conditions, enrichment factors for the three fungicides varied from 145 to 178. The limits of detection for azoxystrobin, diethofencarb and pyrimethanil were 0.08, 0.16 and 0.25 µg L(-1), respectively. Reasonable relative recoveries were varied from 72.3 to 108.0%. And satisfactory intra-assay (5.3-6.2%, n = 6) and inter-assay (6.8-9.3%, n = 6) precision illustrated good performance of the analytical procedure. PMID:25355900

  5. FEASIBILITY OF DEVELOPING SOURCE SAMPLING METHODS FOR ASBESTOS EMISSIONS

    EPA Science Inventory

    The objective of this program was to determine the feasibility of developing methods for sampling asbestos in the emissions of major asbestos sources: (1) ore production and taconite production, (2) asbestos-cement production, (3) asbestos felt and paper production, and (4) the p...

  6. METHODS FOR THE ANALYSIS OF CARPET SAMPLES FOR ASBESTOS

    EPA Science Inventory

    Assessing asbestos fiber contamination in a carpet is complicated by the nature of the carpeting – because of the pile’s rough surface and thickness, samples cannot be collected directly from carpet for analysis by TEM. Two indirect methods are currently used by laboratories when...

  7. SAMPLING AND ANALYSIS METHODS FOR AMBIENT PM-10 AEROSOL

    EPA Science Inventory

    Methods are described for obtaining ambient PM-10 aerosol data for use in receptor models. haracteristics of PM-10 sampling devices, filter media and laboratory analysis procedures are described. he latter include x-ray fluorescence, neutron activation, optical spectroscopy, pyro...

  8. A General Linear Method for Equating with Small Samples

    ERIC Educational Resources Information Center

    Albano, Anthony D.

    2015-01-01

    Research on equating with small samples has shown that methods with stronger assumptions and fewer statistical estimates can lead to decreased error in the estimated equating function. This article introduces a new approach to linear observed-score equating, one which provides flexible control over how form difficulty is assumed versus estimated…

  9. Periodicity detection method for small-sample time series datasets.

    PubMed

    Tominaga, Daisuke

    2010-01-01

    Time series of gene expression often exhibit periodic behavior under the influence of multiple signal pathways, and are represented by a model that incorporates multiple harmonics and noise. Most of these data, which are observed using DNA microarrays, consist of few sampling points in time, but most periodicity detection methods require a relatively large number of sampling points. We have previously developed a detection algorithm based on the discrete Fourier transform and Akaike's information criterion. Here we demonstrate the performance of the algorithm for small-sample time series data through a comparison with conventional and newly proposed periodicity detection methods based on a statistical analysis of the power of harmonics.We show that this method has higher sensitivity for data consisting of multiple harmonics, and is more robust against noise than other methods. Although "combinatorial explosion" occurs for large datasets, the computational time is not a problem for small-sample datasets. The MATLAB/GNU Octave script of the algorithm is available on the author's web site: http://www.cbrc.jp/%7Etominaga/piccolo/. PMID:21151841

  10. Development of an automated data processing method for sample to sample comparison of seized methamphetamines.

    PubMed

    Choe, Sanggil; Lee, Jaesin; Choi, Hyeyoung; Park, Yujin; Lee, Heesang; Pyo, Jaesung; Jo, Jiyeong; Park, Yonghoon; Choi, Hwakyung; Kim, Suncheun

    2012-11-30

    The information about the sources of supply, trafficking routes, distribution patterns and conspiracy links can be obtained from methamphetamine profiling. The precursor and synthetic method for the clandestine manufacture can be estimated from the analysis of minor impurities contained in methamphetamine. Also, the similarity between samples can be evaluated using the peaks that appear in chromatograms. In South Korea, methamphetamine was the most popular drug but the total seized amount of methamphetamine whole through the country was very small. Therefore, it would be more important to find the links between samples than the other uses of methamphetamine profiling. Many Asian countries including Japan and South Korea have been using the method developed by National Research Institute of Police Science of Japan. The method used gas chromatography-flame ionization detector (GC-FID), DB-5 column and four internal standards. It was developed to increase the amount of impurities and minimize the amount of methamphetamine. After GC-FID analysis, the raw data have to be processed. The data processing steps are very complex and require a lot of time and effort. In this study, Microsoft Visual Basic Application (VBA) modules were developed to handle these data processing steps. This module collected the results from the data into an Excel file and then corrected the retention time shift and response deviation generated from the sample preparation and instruments analysis. The developed modules were tested for their performance using 10 samples from 5 different cases. The processed results were analyzed with Pearson correlation coefficient for similarity assessment and the correlation coefficient of the two samples from the same case was more than 0.99. When the modules were applied to 131 seized methamphetamine samples, four samples from two different cases were found to have the common origin and the chromatograms of the four samples were appeared visually identical

  11. Monitoring organic nitrogen species in the UT/LS - a new system for analysis of CARIBIC whole air samples

    NASA Astrophysics Data System (ADS)

    Sauvage, Carina; Thorenz, Ute; Baker, Angela; Brenninkmeijer, Carl; Williams, Jonathan

    2014-05-01

    The CARIBIC project is a unique program for long term and global scale monitoring of the atmosphere (http://www.caribic-atmospheric.com). An instrument container is installed monthly into a civil aircraft operated by Lufthansa (Airbus A 340-600) and makes atmospheric observations en route from Frankfurt, Germany to various destinations around the globe. In four to six long distance flights at a cruising altitude of 10 to 12 km online measurements of various atmospheric tracers are performed during the flight as well as whole air samples are taken with two different sampling units (116 samples in both glass and stainless steel canisters). These samples are routinely analyzed for greenhouse gases, non-methane hydrocarbons (NMHC) and halogenated compounds. Nitrogen containing compounds play various important roles in the atmosphere. Alkyl nitrates (RONO2) are products of the reaction of NMHC with OH and other oxidants in the presence of NO. They can provide information on the oxidative history of an air mass. Moreover they influence photolchemical ozone formation and act as a transport mechanism for reactive nitrogen. Less reactive nitrogen containing species such as HCN and acetonitrile are important markers for biomass burning, while organic amines are involved in gas to particle partitioning. Finally N2O is a long lived nitrogen containing gas important for the Earth's radiative budget. Regular measurements of such nitrogen compounds would therefore be a significant contribution to the CARIBIC data set. Especially for high altitude samples, in which the mixing ratios of many species are expected to be in the low ppt range, a highly sensitive method for analysis is required. Therefore a new system for measurement of nitrogen compounds has been built up, comprising a gas chromatograph (GC) using a nitrogen chemiluminescence detector (NCD). An important advantage of the NCD is that it is selective for nitrogen and equimolar. The nitrogen compounds are sequentially pre

  12. A Model Using Local Weather Data to Determine the Effective Sampling Volume for PCB Congeners Collected on Passive Air Samplers

    PubMed Central

    2016-01-01

    We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF–PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, predicts the Veff as a function of physical-chemical properties of each compound and meteorology from the closest Integrated Surface Database (ISD) data set obtained through NOAA’s National Centers for Environmental Information (NCEI). The model was developed to be user-friendly, only requiring basic Matlab knowledge. To illustrate the effectiveness of the model, we evaluated three independent data sets of airborne PCBs simultaneously collected using passive and active samplers: at sites in Chicago, Lancaster, UK, and Toronto, Canada. The model provides Veff values comparable to those using depuration compounds and calibration against active samplers, yielding an average congener specific concentration method ratio (active/passive) of 1.1 ± 1.2. We applied the model to PUF–PAS samples collected in Chicago and show that previous methods can underestimate concentrations of PCBs by up to 40%, especially for long deployments, deployments conducted under warming conditions, and compounds with log Koa values less than 8. PMID:26963482

  13. A Model Using Local Weather Data to Determine the Effective Sampling Volume for PCB Congeners Collected on Passive Air Samplers.

    PubMed

    Herkert, Nicholas J; Martinez, Andres; Hornbuckle, Keri C

    2016-07-01

    We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF-PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, predicts the Veff as a function of physical-chemical properties of each compound and meteorology from the closest Integrated Surface Database (ISD) data set obtained through NOAA's National Centers for Environmental Information (NCEI). The model was developed to be user-friendly, only requiring basic Matlab knowledge. To illustrate the effectiveness of the model, we evaluated three independent data sets of airborne PCBs simultaneously collected using passive and active samplers: at sites in Chicago, Lancaster, UK, and Toronto, Canada. The model provides Veff values comparable to those using depuration compounds and calibration against active samplers, yielding an average congener specific concentration method ratio (active/passive) of 1.1 ± 1.2. We applied the model to PUF-PAS samples collected in Chicago and show that previous methods can underestimate concentrations of PCBs by up to 40%, especially for long deployments, deployments conducted under warming conditions, and compounds with log Koa values less than 8. PMID:26963482

  14. Complex mixtures and indoor air pollution: overview of epidemiologic methods.

    PubMed Central

    Weiss, N S

    1993-01-01

    The likelihood of an epidemiologic study correctly identifying an adverse health outcome associated with exposure to indoor air pollutants is increased if a) substantial variation exists in the frequency or level of exposure among study subjects otherwise at similar risk of the health outcome; b) the number of study subjects or study communities is large; c) the health outcome can be assessed with accuracy; d) relevant exposure levels can be measured with accuracy; e) an unbiased sample of exposed and nonexposed subjects is selected for study; and f) other determinants of the adverse health outcome can be measured. Nonetheless, given a strong enough impact of exposure to one pollutant or a mixture of pollutants on the risk of illness, it is possible for epidemiologic studies to discern a relation even if only some of the above circumstances are present. PMID:8206026

  15. Comparison of DNA preservation methods for environmental bacterial community samples

    USGS Publications Warehouse

    Gray, Michael A.; Pratte, Zoe A.; Kellogg, Christina A.

    2013-01-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard™, RNAlater®, DMSO–EDTA–salt (DESS), FTA® cards, and FTA Elute® cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA® cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard™, RNAlater®, and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost.

  16. Comparison of aquatic macroinvertebrate samples collected using different field methods

    USGS Publications Warehouse

    Lenz, Bernard N.; Miller, Michael A.

    1996-01-01

    Government agencies, academic institutions, and volunteer monitoring groups in the State of Wisconsin collect aquatic macroinvertebrate data to assess water quality. Sampling methods differ among agencies, reflecting the differences in the sampling objectives of each agency. Lack of infor- mation about data comparability impedes data shar- ing among agencies, which can result in duplicated sampling efforts or the underutilization of avail- able information. To address these concerns, com- parisons were made of macroinvertebrate samples collected from wadeable streams in Wisconsin by personnel from the U.S. Geological Survey- National Water Quality Assessment Program (USGS-NAWQA), the Wisconsin Department of Natural Resources (WDNR), the U.S. Department of Agriculture-Forest Service (USDA-FS), and volunteers from the Water Action Volunteer-Water Quality Monitoring Program (WAV). This project was part of the Intergovernmental Task Force on Monitoring Water Quality (ITFM) Wisconsin Water Resources Coordination Project. The numbers, types, and environmental tolerances of the organ- isms collected were analyzed to determine if the four different field methods that were used by the different agencies and volunteer groups provide comparable results. Additionally, this study com- pared the results of samples taken from different locations and habitats within the same streams.

  17. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2013-01-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change is likely to have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological advances in the CFC production process over the last 80 yr, though direct evidence is lacking.

  18. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Rubino, M.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2012-07-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change must have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological changes in the CFC production process over the last 80 yr. Propagating the mass-balance calculations into the future demonstrates that as emissions decrease to zero, isotopic fractionation by the stratospheric sinks will lead to continued 13C enrichment in atmospheric CFC-12.

  19. Evaluation of Environmental Sample Analysis Methods and Results Reporting in the National Children's Study Vanguard Study.

    PubMed

    Heikkinen, Maire S A; Khalaf, Abdisalam; Beard, Barbara; Viet, Susan M; Dellarco, Michael

    2016-05-01

    During the initial Vanguard phase of the U.S. National Children's Study (NCS), about 2000 tap water, surface wipe, and air samples were collected and analyzed immediately. The shipping conditions, analysis methods, results, and laboratory performance were evaluated to determine the best approaches for use in the NCS Main Study. The main conclusions were (1) to employ established sample analysis methods, when possible, and alternate methodologies only after careful consideration with method validation studies; (2) lot control and prescreening sample collection materials are important quality assurance procedures; (3) packing samples correctly requires careful training and adjustment of shipping conditions to local conditions; (4) trip blanks and spiked samples should be considered for samplers with short expiration times and labile analytes; (5) two study-specific results reports should be required: laboratory electronic data deliverables (EDD) of sample results in a useable electronic format (CSV or SEDD XML/CSV) and a data package with sample results and supporting information in PDF format. These experiences and lessons learned can be applied to any long-term study. PMID:27049443

  20. Interconversion of chromium species during air sampling: effects of O3, NO2, SO2, particle matrices, temperature, and humidity.

    PubMed

    Huang, Lihui; Fan, Zhihua Tina; Yu, Chang Ho; Hopke, Philip K; Lioy, Paul J; Buckley, Brian T; Lin, Lin; Ma, Yingjun

    2013-05-01

    The interconversion between Cr(VI), a pulmonary carcinogen, and Cr(III), an essential human nutrient, poses challenges to the measurement of Cr(VI) in airborne particles. Chamber and field tests were conducted to identify the factors affecting Cr(VI)-Cr(III) interconversion in the basic filter medium under typical sampling conditions. In the chamber tests, isotopically enriched (53)Cr(VI) and (50)Cr(III) were spiked on diesel particulate matter (DPM) and secondary organic aerosol (SOA) that were precollected on a basic MCE filter. The filter samples were then exposed to clean air or the air containing SO2 (50 and 160 ppb), 100 ppb O3, or 150 ppb NO2 for 24 h at 16.7 LPM flow rate at designated temperature (20 and 31 °C) and RH (40% and 70%) conditions. Exposure to 160 ppb SO2 had the greatest effect on (53)Cr(VI) reduction, with (53)Cr(VI) recovery of 31.7 ± 15.8% (DPM) and 42.0 ± 7.9% (SOA). DPM and SOA matrix induced (53)Cr(VI) reduction when exposed to clean air while reactive oxygen species in SOA could promote (50)Cr(III) oxidation. Deliquescence when RH increased from 40% to 70% led to conversion of Cr(III) in SOA, whereas oxidized organics in DPM and SOA enhanced hygroscopicity and thus facilitated Cr(VI) reduction. Field tests showed seasonal variation of Cr(VI)-Cr(III) interconversion during sampling. Correction of the interconversion using USEPA method 6800 is recommended to improve accuracy of ambient Cr(VI) measurements. PMID:23550818