Science.gov

Sample records for air sampling methods

  1. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

    SciTech Connect

    Maxwell, S.; Noyes, G.; Culligan, B.

    2010-02-03

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

  2. Passive Samplers for Investigations of Air Quality: Method Description, Implementation, and Comparison to Alternative Sampling Methods

    EPA Science Inventory

    This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...

  3. Field evaluation of endotoxin air sampling assay methods.

    PubMed

    Thorne, P S; Reynolds, S J; Milton, D K; Bloebaum, P D; Zhang, X; Whitten, P; Burmeister, L F

    1997-11-01

    This study tested the importance of filter media, extraction and assay protocol, and bioaerosol source on the determination of endotoxin under field conditions in swine and poultry confinement buildings. Multiple simultaneous air samples were collected using glass fiber (GF) and polycarbonate (PC) filters, and these were assayed using two methods in two separate laboratories: an endpoint chromogenic Limulus amebocyte lysate (LAL) assay (QCL) performed in water and a kinetic chromogenic LAL assay (KQCL) performed in buffer with resistant-parallel line estimation analysis (KLARE). In addition, two aqueous filter extraction methods were compared in the QCL assay: 120 min extraction at 22 degrees C with vigorous shaking and 30 min extraction at 68 degrees C with gentle rocking. These extraction methods yielded endotoxin activities that were not significantly different and were very highly correlated. Reproducibility of endotoxin determinations from duplicate air sampling filters was very high (Cronbach alpha all > 0.94). When analyzed by the QCL method GF filters yielded significantly higher endotoxin activity than PC filters. QCL and KLARE methods gave similar estimates for endotoxin activity from PC filters; however, GF filters analyzed by the QCL method yielded significantly higher endotoxin activity estimates, suggesting enhancement of the QCL assay or inhibition of the KLARE asay with GF filters. Correlation between QCL-GF and QCL-PC was high (r = 0.98) while that between KLARE-GF and KLARE-PC was moderate (r = 0.68). Analysis of variance demonstrated that assay methodology, filter-type, barn-type, and interactions between assay and filter-type and between assay and barn-type were important factors influencing endotoxin exposure assessment.

  4. Identification of ambient air sampling and analysis methods for the 189 Title III air toxics

    SciTech Connect

    Mukund, R.; Kelly, T.J.; Gordon, S.M.; Hays, M.J.

    1994-12-31

    The state of development of ambient air measurement methods for the 189 Hazardous Air Pollution (HAPs) in Title 3 of the Clean Air Act Amendments was surveyed. Measurement methods for the HAPs were identified by reviews of established methods, and by literature searches for pertinent research techniques. Methods were segregated by their degree of development into Applicable, Likely, and Potential methods. This survey identified a total of 183 methods, applicable at varying degrees to ambient air measurements of one or more HAPs. As a basis for classifying the HAPs and evaluating the applicability of measurement methods, a survey of a variety of chemical and physical properties of the HAPs was also conducted. The results of both the methods and properties surveys were tabulated for each of the 189 HAP. The current state of development of ambient measurement methods for the 189 HAPs was then assessed from the results of the survey, and recommendations for method development initiatives were developed.

  5. Review of Various Air Sampling Methods for Solvent Vapors.

    ERIC Educational Resources Information Center

    Maykoski, R. T.

    Vapors of trichloroethylene, toluene, methyl ethyl ketone, and butyl cellosolve in air were collected using Scotchpac and Tedlar bags, glass prescription bottles, and charcoal adsorption tubes. Efficiencies of collection are reported. (Author/RH)

  6. A method for sampling halothane and enflurane present in trace amounts in ambient air.

    PubMed

    Burm, A G; Spierdijk, J

    1979-03-01

    A method for the sampling of small amounts of halothane and enflurane in ambient air is described. Sampling is performed by drawing air through a sampling tube packed with Porapak Q, which absorbs the anesthetic agent. The amount absorbed is determined by gas chromatography after thermal desorption. This method can be used for "spot" or personal sampling or for determining mean whole-room concentrations over relatively long periods (several hours).

  7. A method to optimize sampling locations for measuring indoor air distributions

    NASA Astrophysics Data System (ADS)

    Huang, Yan; Shen, Xiong; Li, Jianmin; Li, Bingye; Duan, Ran; Lin, Chao-Hsin; Liu, Junjie; Chen, Qingyan

    2015-02-01

    Indoor air distributions, such as the distributions of air temperature, air velocity, and contaminant concentrations, are very important to occupants' health and comfort in enclosed spaces. When point data is collected for interpolation to form field distributions, the sampling locations (the locations of the point sensors) have a significant effect on time invested, labor costs and measuring accuracy on field interpolation. This investigation compared two different sampling methods: the grid method and the gradient-based method, for determining sampling locations. The two methods were applied to obtain point air parameter data in an office room and in a section of an economy-class aircraft cabin. The point data obtained was then interpolated to form field distributions by the ordinary Kriging method. Our error analysis shows that the gradient-based sampling method has 32.6% smaller error of interpolation than the grid sampling method. We acquired the function between the interpolation errors and the sampling size (the number of sampling points). According to the function, the sampling size has an optimal value and the maximum sampling size can be determined by the sensor and system errors. This study recommends the gradient-based sampling method for measuring indoor air distributions.

  8. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  9. COMPARISON OF FAST GC/TOFMS WITH METHOD TO-14 FOR ANALYSIS OF AMBIENT AIR SAMPLES

    EPA Science Inventory

    Field studies using portable gas chromatographs (PGC) to analyze volatile organic compounds in ambient air usually include, as reference standard method, the analysis of concurrent, collocated canister samples by EPA Method TO-14. Each laboratory analysis takes about an hour a...

  10. Evaluation of sampling and analytical methods for the determination of chlorodifluoromethane in air.

    PubMed

    Seymour, M J; Lucas, M F

    1993-05-01

    In January 1989, the Occupational Safety and Health Administration (OSHA) published revised permissible exposure limits (PELs) for 212 compounds and established PELs for 164 additional compounds. In cases where regulated compounds did not have specific sampling and analytical methods, methods were suggested by OSHA. The National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods (NMAM) Method 1020, which was developed for 1,1,2-trichloro-1,2,2-trifluoroethane, was suggested by OSHA for the determination of chlorodifluoromethane in workplace air. Because this method was developed for a liquid and chlorodifluoromethane is a gas, the ability of NMAM Method 1020 to adequately sample and quantitate chlorodifluoromethane was questioned and tested by researchers at NIOSH. The evaluation of NMAM Method 1020 for chlorodifluoromethane showed that the capacity of the 100/50-mg charcoal sorbent bed was limited, the standard preparation procedure was incorrect for a gas analyte, and the analyte had low solubility in carbon disulfide. NMAM Method 1018 for dichlorodifluoromethane uses two coconut-shell charcoal tubes in series, a 400/200-mg tube followed by a 100/50-mg tube, which are desorbed with methylene chloride. This method was evaluated for chlorodifluoromethane. Test atmospheres, with chlorodifluoromethane concentrations from 0.5-2 times the PEL were generated. Modifications of NMAM Method 1018 included changes in the standard preparation procedure, and the gas chromatograph was equipped with a capillary column. These revisions to NMAM 1018 resulted in a 96.5% recovery and a total precision for the method of 7.1% for chlorodifluoromethane. No significant bias in the method was found. Results indicate that the revised NMAM Method 1018 is suitable for the determination of chlorodifluoromethane in workplace air.

  11. A STRINGENT COMPARISON OF SAMPLING AND ANALYSIS METHODS FOR VOCS IN AMBIENT AIR

    EPA Science Inventory

    A carefully designed study was conducted during the summer of 1998 to simultaneously collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. A total of 32 1-h sample sets we...

  12. Air-spore in Cartagena, Spain: viable and non-viable sampling methods.

    PubMed

    Elvira-Rendueles, Belen; Moreno, Jose; Garcia-Sanchez, Antonio; Vergara, Nuria; Martinez-Garcia, Maria Jose; Moreno-Grau, Stella

    2013-01-01

    In the presented study the airborne fungal spores of the semiarid city of Cartagena, Spain, are identified and quantified by means of viable or non-viable sampling methods. Airborne fungal samples were collected simultaneously using a filtration method and a pollen and particle sampler based on the Hirst methodology. This information is very useful for elucidating geographical patterns of hay fever and asthma. The qualitative results showed that when the non-viable methodology was employed, Cladosporium, Ustilago, and Alternaria were the most abundant spores identified in the atmosphere of Cartagena, while the viable methodology showed that the most abundant taxa were: Cladosporium, Penicillium, Aspergillus and Alternaria. The quantitative results of airborne fungal spores identified by the Hirst-type air sampler (non-viable method), showed that Deuteromycetes represented 74% of total annual spore counts, Cladosporium being the major component of the fungal spectrum (62.2%), followed by Alternaria (5.3%), and Stemphylium (1.3%). The Basidiomycetes group represented 18.9% of total annual spore counts, Ustilago (7.1%) being the most representative taxon of this group and the second most abundant spore type. Ascomycetes accounted for 6.9%, Nectria (2.3%) being the principal taxon. Oomycetes (0.2%) and Zygomycestes and Myxomycestes (0.06%) were scarce. The prevailing species define our bioaerosol as typical of dry air. The viable methodology was better at identifying small hyaline spores and allowed for the discrimination of the genus of some spore types. However, non-viable methods revealed the richness of fungal types present in the bioaerosol. Thus, the use of both methodologies provides a more comprehensive characterization of the spore profile.

  13. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings. PMID:27569522

  14. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.

  15. Evaluation of a modified sampling method for molecular analysis of air microflora.

    PubMed

    Lech, T; Ziembinska-Buczynska, A

    2015-04-10

    A serious issue concerning the durability of economically important materials for humans related to cultural heritage is the process of biodeterioration. As a result of this phenomenon, priceless works of art, documents, and old prints have undergone a process of decomposition caused by microorganisms. Therefore, it is important to constantly monitor the presence and diversity of microorganisms in exposition rooms and storage areas of historical objects. In addition, the use of molecular biology tools for conservation studies will enable detailed research as well as reduce the time needed to perform the analyses compared with using conventional methods related to microbiology and conservation. The aim of this study was to adapt the sampling indoor air method for direct DNA extraction from microorganisms, including evaluating the extracted DNA quality and concentration. The obtained DNA was used to study the diversity of mold fungi in indoor air using polymerase chain reaction-denaturing gradient gel electrophoresis in specific archives and museum environments. The research was conducted in 2 storage rooms of the National Archives in Krakow and in 1 exposition room of the Archaeological Museum in Krakow (Poland).

  16. Uncertainties in Air Exchange using Continuous-Injection, Long-Term Sampling Tracer-Gas Methods

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.; Lunden, Melissa M.

    2013-12-01

    The PerFluorocarbon Tracer (PFT) method is a low-cost approach commonly used for measuring air exchange in buildings using tracer gases. It is a specific application of the more general Continuous-Injection, Long-Term Sampling (CILTS) method. The technique is widely used but there has been little work on understanding the uncertainties (both precision and bias) associated with its use, particularly given that it is typically deployed by untrained or lightly trained people to minimize experimental costs. In this article we will conduct a first-principles error analysis to estimate the uncertainties and then compare that analysis to CILTS measurements that were over-sampled, through the use of multiple tracers and emitter and sampler distribution patterns, in three houses. We find that the CILTS method can have an overall uncertainty of 10-15percent in ideal circumstances, but that even in highly controlled field experiments done by trained experimenters expected uncertainties are about 20percent. In addition, there are many field conditions (such as open windows) where CILTS is not likely to provide any quantitative data. Even avoiding the worst situations of assumption violations CILTS should be considered as having a something like a ?factor of two? uncertainty for the broad field trials that it is typically used in. We provide guidance on how to deploy CILTS and design the experiment to minimize uncertainties.

  17. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  18. Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.

    PubMed

    Woolfenden, Elizabeth

    2010-04-16

    Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents

  19. High-throughput liquid-absorption air-sampling apparatus and methods

    DOEpatents

    Zaromb, Solomon

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is <10 cm of water, usually <5 cm of water. The sampler's collection efficiency is usually >20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  20. Development of a combined air sampling and quantitative real-time PCR method for detection of Legionella spp.

    PubMed

    Sirigul, Chomrach; Wongwit, Waranya; Phanprasit, Wantanee; Paveenkittiporn, Wantana; Blacksell, Stuart D; Ramasoota, Pongrama

    2006-05-01

    The objective of this study was to develop and optimize the combined methods of air sampling and real time polymerase chain reaction (real-time PCR) for quantifying aerosol Legionella spp. Primers and TaqMan hydrolysis probe based on 5S rRNA gene specific for Legionella spp were used to amplify a specific DNA product of 84 bp. The impinger air sampler plus T-100 sampling pump was used to collect aerosol Legionella and as low as 10 fg of Legionella DNA per reaction could detected. Preliminary studies demonstrated that the developed method could detect aerosol Legionella spp 1.5-185 organisms /500 l of air within 5 hours, in contrast to culture method, that required a minimum of 7-10 days. PMID:17120970

  1. Air sampling in the workplace. Final report

    SciTech Connect

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC`s Regulatory Guide 8.25, Revision 1, ``Air sampling in the Workplace.`` That guide addresses air sampling to meet the requirements in NRC`s regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed.

  2. An analytical method for trifluoroacetic Acid in water and air samples using headspace gas chromatographic determination of the methyl ester.

    PubMed

    Zehavi, D; Seiber, J N

    1996-10-01

    An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA. PMID:21619278

  3. Thermal desorption-gas chromatography-mass spectrometry method to determine phthalate and organophosphate esters from air samples.

    PubMed

    Aragón, M; Borrull, F; Marcé, R M

    2013-08-16

    A method based on thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) has been developed to determine four organophosphate esters, seven phthalate esters, and bis(2-ethylhexyl) adipate in the gas phase from harbour and urban air samples. The method involves the sampling of 1.5L of air in a Tenax TA sorbent tube followed by thermal desorption (using a Tenax TA cryogenic trap) coupled to gas chromatography-mass spectrometry. The repeatability of the method expressed as %RSD (n=3) is less than 15% and the MQLs are between 0.007μgm(-3) (DMP, TBP, BBP, TPP and DnOP) and 6.7μgm(-3) (DEHP). The method was successfully applied in two areas (urban and harbour) testing two and three points in each one, respectively. Some of these compounds were found in both urban and harbour samples. Di-(2-ethylhexyl)phthalate was the most abundant compound found in both areas at concentration levels between 6.7μgm(-3) and 136.4μgm(-3). This study demonstrates that thermal desorption is an efficient method for the determination of these semi-volatile compounds in the gas phase fraction of air samples.

  4. Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

    PubMed

    Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud

    2016-03-01

    Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments.

  5. Evaluation of a method to detect Mycobacterium bovis in air samples from infected Eurasian badgers (Meles meles) and their setts.

    PubMed

    Jones, R M; Ashford, R; Cork, J; Palmer, S; Wood, E; Spyvee, P; Parks, S; Bennett, A; Brewer, J; Delahay, R; Chambers, M; Sawyer, J

    2013-05-01

    Environmental air sampling was evaluated as a method to detect the presence of M. bovis in the vicinity of infected badgers and their setts. Airborne particles were collected on gelatine filters using a commercially available air sampling instrument and tested for the presence of M. bovis using bacteriological culture and real-time PCR. The sensitivity of bacteriological culture was broadly similar to that of real-time PCR when testing samples artificially spiked with M. bovis. Sampling was undertaken from directly under the muzzles of badgers which had been experimentally infected with M. bovis (37 samples), within enclosures housing the experimentally infected animals (50 samples), and in the vicinity of setts with resident infected wild badgers (52 samples). The methods employed did not detect M. bovis from either infected badgers or artificial or natural setts known to contain infected animals. However, samples taken at four of the six natural setts were positive for Mycobacterium gordonae.

  6. Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air

    SciTech Connect

    Harless, R.L.; Lewis, R.G.; McDaniel, D.D.; Gibson, J.F.; Dupuy, A.E.

    1992-01-01

    General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenz-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cubic meter ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C-12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cubic meter and sub-pg/cubic meter levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured.

  7. Improved Sampling Method Reduces Isokinetic Sampling Errors.

    ERIC Educational Resources Information Center

    Karels, Gale G.

    The particulate sampling system currently in use by the Bay Area Air Pollution Control District, San Francisco, California is described in this presentation for the 12th Conference on Methods in Air Pollution and Industrial Hygiene Studies, University of Southern California, April, 1971. The method represents a practical, inexpensive tool that can…

  8. Development of a method to detect and quantify Aspergillus fumigatus conidia by quantitative PCR for environmental air samples.

    PubMed

    McDevitt, James J; Lees, Peter S J; Merz, William G; Schwab, Kellogg J

    2004-10-01

    Exposure to Aspergillus fumigatus is linked with respiratory diseases such as asthma, invasive aspergillosis, hypersensitivity pneumonitis, and allergic bronchopulmonary aspergillosis. Molecular methods using quantitative PCR (qPCR) offer advantages over culture and optical methods for estimating human exposures to microbiological agents such as fungi. We describe an assay that uses lyticase to digest A. fumigatus conidia followed by TaqMan qPCR to quantify released DNA. This method will allow analysis of airborne A. fumigatus samples collected over extended time periods and provide a more representative assessment of chronic exposure. The method was optimized for environmental samples and incorporates: single tube sample preparation to reduce sample loss, maintain simplicity, and avoid contamination; hot start amplification to reduce non-specific primer/probe annealing; and uracil-N-glycosylase to prevent carryover contamination. An A. fumigatus internal standard was developed and used to detect PCR inhibitors potentially found in air samples. The assay detected fewer than 10 A. fumigatus conidia per qPCR reaction and quantified conidia over a 4-log10 range with high linearity (R2 >0.99) and low variability among replicate standards (CV=2.0%) in less than 4 h. The sensitivity and linearity of qPCR for conidia deposited on filters was equivalent to conidia calibration standards. A. fumigatus DNA from 8 isolates was consistently quantified using this method, while non-specific DNA from 14 common environmental fungi, including 6 other Aspergillus species, was not detected. This method provides a means of analyzing long term air samples collected on filters which may enable investigators to correlate airborne environmental A. fumigatus conidia concentrations with adverse health effects.

  9. Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air

    SciTech Connect

    Harless, R.L.; Lewis, R.G.; McDaniel, D.D.; Gibson, J.F.; Dupuy, A.E.

    1991-01-01

    General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C12-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cu m ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cu m and sub-pg/cu m levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured. Background levels of these compounds in the ambient air were also determined. Total PCDDs, PCDFs, TBDFs, and PeBDFs were detected in a low concentration range of 0.3 to 3.0 pg/cu m.

  10. Procedures manual for the recommended ARB (Air Resources Board) sized chemical sample method (cascade cyclones)

    SciTech Connect

    McCain, J.D.; Dawes, S.S.; Farthing, W.E.

    1986-05-01

    The report is Attachment No. 2 to the Final Report of ARB Contract A3-092-32 and provides a tutorial on the use of Cascade (Series) Cyclones to obtain size-fractionated particulate samples from industrial flue gases at stationary sources. The instrumentation and procedures described are designed to protect the purity of the collected samples so that post-test chemical analysis may be performed for organic and inorganic compounds, including instrumental analysis for trace elements. The instrumentation described collects bulk quantities for each of six size fractions over the range 10 to 0.4 micrometer diameter. The report describes the operating principles, calibration, and empirical modeling of small cyclone performance. It also discusses the preliminary calculations, operation, sample retrieval, and data analysis associated with the use of cyclones to obtain size-segregated samples and to measure particle-size distributions.

  11. Field comparison of air sampling methods for monomeric and polymeric 1,6-hexamethylene diisocyanate.

    PubMed

    Thomasen, Jennifer M; Fent, Kenneth W; Reeb-Whitaker, Carolyn; Whittaker, Stephen G; Nylander-French, Leena A

    2011-03-01

    This study was to critically compared 13 different air samplers for their ability to monitor air exposures to monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI) in the automotive refinishing industry. Using both fast- and slow-drying clearcoat, we tested the following types of samplers: single- and dual-stage 37-mm polypropylene (PP) and polystyrene (PS) samplers (open- and closed-face), IOM (with plastic and stainless steel inserts), OSHA42, IsoChek, and WA-DOSH samplers. Midget impingers with frit were used as reference samplers. We observed the PP, PS, and IOM samplers to measure greater levels of HDI monomer and biuret when a fast-drying clearcoat was applied compared with a slow-drying clearcoat. When a slow-drying clearcoat was applied, the open-face PP and PS samplers measured significantly more monomeric and polymeric HDI (2-fold; p < 0.003) than the closed-face PP and PS samplers. We determined that significantly more monomeric and polymeric HDI were measured by impingers (1.3-1.9-fold) compared with single-stage PP/PS (N = 59), dual-stage PP/PS (N = 59), or IOM (N = 24) samplers. However, when stratified by cassette characteristics, the open-face single-stage PP and PS samplers performed equally to the impingers for HDI monomer when a fast-drying clearcoat was applied, and for all analytes when a slow-drying clearcoat was applied. Significantly higher HDI monomer concentrations (1.2-3.1-fold; p = 0.001) were measured with OSHA42 compared with the impinger. The IsoChek did not detect HDI monomer, and of the three samplers analyzed by laboratories other than UNC (i.e., OSHA42, IsoChek, and WA-DOSH), the WA-DOSH was in the best agreement with the impingers. The influence of clearcoat drying time on the sampler's ability to measure monomeric and polymeric HDI emphasizes the importance of the speciation of diisocyanates in chemical analysis and the careful consideration for the selection of the air sampler to be used when measuring exposures during

  12. Auditing of sampling methods for air toxics at coal-fired power plants

    SciTech Connect

    Agbede, R.O.; Clements, J.L.; Grunebach, M.G.

    1995-11-01

    Advanced Technology Systems, Inc. (ATS) with subcontract assistance from international Technology Corporation (IT) has provided external audit activities for Phase II of the Department of Energy-Pittsburgh Energy Technology Center`s air emission test program. The objective of the audits is to help ensure that the data obtained from the emission tests are precise, accurate, representative, scientifically sound and legally defensible. This paper presents the criteria that were used to perform the external audits of the emission test program. It also describes the approach used by ATS and It in performing their audits. Examples of findings of the audits along with the actions take to correct problems and the subsequent effect of those actions on the test data are presented. The results of audit spikes performed at the Plant 1 test site are also discussed.

  13. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, Katharine H.

    1990-01-01

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

  14. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1990-05-22

    An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  15. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1987-12-10

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  16. Development of Methods for Sampling and Analysis of Polychlorinated Naphthalenes in Ambient Air

    ERIC Educational Resources Information Center

    Erickson, Mitchell D.; And Others

    1978-01-01

    The procedure and sampler described permits detection of less than 50pg of one polychlorinated naphthalene (PCN) isomer. The method uses gas chromatography-mass spectrometry. The PCNs are collected on a glass fiber filter and two polyurethane foam plugs and extracted with toluene at 25 degrees Celsius. (BB)

  17. Vortex and air assisted liquid-liquid microextraction as a sample preparation method for high-performed liquid chromatography determinations.

    PubMed

    Hosseini, Mohammad; Heydari, Rouhollah; Alimoradi, Mohammad

    2014-12-01

    A novel, simple and sensitive method based on vortex and air assisted liquid-liquid microextraction (VAALLME) technique coupled with high-performance liquid chromatography (HPLC) has been developed for quantitative analysis of β-naphthol, naphthalene and anthracene as model analytes. Unlike the dispersive liquid-liquid microextraction (DLLME), dispersive solvent and centrifuging step were eliminated in proposed technique. In this technique, extraction solvent was dispersed into the aqueous sample solution by using vortex. Phase separation was achieved via motion of air bubbles from the bottom to top of the extraction tube, which promoted the analytes transfer into the supernatant organic phase. Influential parameters on the extraction efficiency such as type and volume of extraction solvent, salt type and its concentration, vortex and aeration times, and sample pH were evaluated and optimized. The calibration curves showed good linearity (r(2)>0.9947) and precision (RSD<5.0%) in the working concentration ranges. The limit of detection (LOD) for β-naphthol, naphthalene and anthracene were 10, 5.0 and 0.5 ng mL(-1), respectively. The recoveries were in the range of 97.0-102.0% with RSD values ranging from 2.2 to 5.2%.

  18. Methods for polynuclear aromatic hydrocarbon determination in air samples using polar-bonded phase HPLC and GC-MS with application to oil refinery samples

    SciTech Connect

    Karlesky, K.L.

    1985-01-01

    Particle samples were collected using high volume air samplers fitted with glass fiber filters or with a cascade impactor containing paper filters. They were then cleaned using either extraction with dimethylsulfoxide and pentane or utilizing a small cartridge containing a diamine polar-bonded phase material, the second method being more effective. Vapor phase PAH were sampled using an apparatus designed in the laboratory. After collection, the resins were desorbed with solvent and the PAH content was determined. The suitability of the resins decrease in the following order: Amberlite XAD-2, Chromosorb 105, Tenax GC, coconut charcoal, and Ambesorb XE-348. High performance liquid chromatography (HPLC) was used to determine the behavior of PAH in the normal and reversed phase on polar-bonded phases containing amine, diamine, and pyrrolidone substrates. Results support the proposed mechanism in the normal phase and indicate that both a partitioning and liquid-solid adsorption mechanism takes place in the reversed phase depending upon the mobile phase. Occasionally, these polar-bonded phases can be deactivated by the formation of amine-carbonyl complexes from polar aldehydes or ketones in the solvent or sample. Deactivation can be reversed by flushing with water to hydrolyze the Schiff's base imine back to the amine. Gas chromatography-mass spectroscopy (GC-MS) was used to analyze air samples from oil refineries in Port Arthur, collected over a period of three years. The analytical procedures are applied to the collected samples to determine if they contain detectable amounts of PAH. The GC-MS analysis was adequate for this study but the use of SIM detection is preferred because of the greater sensitivity for PAH.

  19. Air sampling with solid phase microextraction

    NASA Astrophysics Data System (ADS)

    Martos, Perry Anthony

    There is an increasing need for simple yet accurate air sampling methods. The acceptance of new air sampling methods requires compatibility with conventional chromatographic equipment, and the new methods have to be environmentally friendly, simple to use, yet with equal, or better, detection limits, accuracy and precision than standard methods. Solid phase microextraction (SPME) satisfies the conditions for new air sampling methods. Analyte detection limits, accuracy and precision of analysis with SPME are typically better than with any conventional air sampling methods. Yet, air sampling with SPME requires no pumps, solvents, is re-usable, extremely simple to use, is completely compatible with current chromatographic equipment, and requires a small capital investment. The first SPME fiber coating used in this study was poly(dimethylsiloxane) (PDMS), a hydrophobic liquid film, to sample a large range of airborne hydrocarbons such as benzene and octane. Quantification without an external calibration procedure is possible with this coating. Well understood are the physical and chemical properties of this coating, which are quite similar to those of the siloxane stationary phase used in capillary columns. The log of analyte distribution coefficients for PDMS are linearly related to chromatographic retention indices and to the inverse of temperature. Therefore, the actual chromatogram from the analysis of the PDMS air sampler will yield the calibration parameters which are used to quantify unknown airborne analyte concentrations (ppb v to ppm v range). The second fiber coating used in this study was PDMS/divinyl benzene (PDMS/DVB) onto which o-(2,3,4,5,6- pentafluorobenzyl) hydroxylamine (PFBHA) was adsorbed for the on-fiber derivatization of gaseous formaldehyde (ppb v range), with and without external calibration. The oxime formed from the reaction can be detected with conventional gas chromatographic detectors. Typical grab sampling times were as small as 5 seconds

  20. Air Sampling System Evaluation Template

    2000-05-09

    The ASSET1.0 software provides a template with which a user can evaluate an Air Sampling System against the latest version of ANSI N13.1 "Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities". The software uses the ANSI N13.1 PIC levels to establish basic design criteria for the existing or proposed sampling system. The software looks at such criteria as PIC level, type of radionuclide emissions, physical state ofmore » the radionuclide, nozzle entrance effects, particulate transmission effects, system and component accuracy and precision evaluations, and basic system operations to provide a detailed look at the subsystems of a monitoring and sampling system/program. A GAP evaluation can then be completed which leads to identification of design and operational flaws in the proposed systems. Corrective measures can then be limited to the GAPs.« less

  1. Methods to infer the compliance status with interval-averaged and with instantaneous occupational exposure limits from the results of longer-duration, integrated air sampling.

    PubMed

    Hunsaker, Harry A

    2016-01-01

    The duration of integrated air sampling for a substance may exceed the time frame of a substance's occupational exposure limit. Nonetheless, the compliance status of a limit may be inferred, under some circumstances, by the application of certain methods to the results of longer-duration samples. The purpose of this article is to define the inference methods and to illustrate their utility with actual and hypothetical examples. A review of articles and reports in U.S.-based Industrial Hygiene publications and databases revealed that the methods often were not but arguably should have been applied. Also revealed were inappropriate conclusions about the compliance status with exposure limits. Among the benefits of employing the inference methods is gaining information on exposures that might otherwise be overlooked. This article discusses the potential limitations of using the methods, and highlights some of the challenges of using integrated air sampling for assessing compliance with shorter-term exposure limits. PMID:26366477

  2. Comparison of three sampling and analytical methods for measuring m-xylene in expired air of exposed humans.

    PubMed

    Glaser, R A; Arnold, J E; Shulman, S A

    1990-03-01

    Three breath sampling and analytical methods were tested following exposure of 12 subjects for 4 hr to 75 ppm m-xylene in a controlled environmental chamber. Mixed-expired breath was sampled for m-xylene from all 12 subjects with a new stainless steel device that permits continuous mainstream or sidestream sampling of the solvents present. The m-xylene was sampled from the mainstream using charcoal cloth and from the sidestream using Tenax TA. Alveolar breath also was sampled for m-xylene from 6 of these subjects using bags. The carbon dioxide concentrations of the mixed and alveolar samples, obtained from these 6 subjects, were also determined and used to assess the accuracy of the mixed-expired sampling and analytical procedures. Breath sampling was conducted over the immediate 240-min postexposure period. All m-xylene samples were analyzed using gas chromatography with flame ionization detection. Carbon dioxide concentrations were determined with an infrared analyzer. Nonlinear regression analysis was used to model the desaturation of m-xylene via the breath. Overall, the desaturation of m-xylene from all subjects by all methods was best described using three-compartment pharmacokinetic models. The precision of each sampling and analytical method, estimated from the residual variabilities of the desaturation curves were 0.13 for alveolar sampling, 0.14 for mainstream-mixed sampling (12 subjects), and 0.23 for sidestream-mixed sampling (12 subjects). For all 12 subjects, the breath m-xylene concentrations determined by sidestream-mixed sampling averaged 83% of those determined by mainstream-mixed sampling; this bias was significant. For the 6 subjects from whom both mixed-expired and alveolar breath samples were obtained, the average m-xylene desaturation rates determined by both mainstream-mixed and alveolar sampling were comparable but substantially different from those determined by sidestream-mixed sampling. For these subjects, comparison of the average and

  3. Development of a sampling and analytical method for 2,2-dichloro-1,1,1-trifluoroethane in workplace air.

    PubMed

    Shin, Yong Chul; Yi, Gwang Yong; Kim, Yangho; Paik, Nam Won

    2002-01-01

    The use of 2,2-dichloro-1,1,1-trifluoroethane (compound number: HCFC-123) is growing in industry as a substitute for ozone-depleting chlorofluorocarbons (CFCs). Recently, liver-related illnesses have been reported from industries handling HCFC-123. However, information on worker exposure to the material is limited, and an acceptable sampling/analytical method is not available. The aim of this study was to develop a widely applicable sampling and analytical method to determine worker exposures to airborne HCFC-123 and to evaluate the performance of the method. A solid sorbent tube, containing two sections (400 mg in the front and 200 mg in the back) of activated coconut-shell charcoal was chosen for sampling airborne HCFC-123 vapor. The breakthrough volumes were 13.6 L at 3597 +/- 210.1 ppm (with a sampling airflow rate of 0.046 L/min) and 17.0 L at 1841 +/- 4.5 ppm (with sampling airflow rate of 0.046-0.050 L/min). Samples of HCFC-123 in the charcoal tube were stable for 7 days either at room temperature or in a refrigerator and a migration occurred within 14 days at room temperature. It is recommended that the HCFC-123 sample in activated charcoal tubes be stored either at room temperature or in a refrigerator and be analyzed within 7 days. The HCFC-123 in the charcoal tubes was desorbed into dichloromethane and analyzed using gas chromatography/ flame ionization detection. The limit of detection was 0.23 mg/sample, and the average desorption efficiency was 99.0%. The total coefficient of variation was 0.060, and the method accuracy was 16.6%. In conclusion, the performance of the sampling and analytical method developed for the determination of airborne HCFC-123 concentrations was acceptable to the NIOSH sampling and analytical criteria. PMID:12570079

  4. Analytical method validation for the determination of 2,3,3,3-tetrafluoropropene in air samples using gas chromatography with flame ionization detection.

    PubMed

    Mawn, Michael P; Kurtz, Kristine; Stahl, Deborah; Chalfant, Richard L; Koban, Mary E; Dawson, Barbara J

    2013-01-01

    A new low global warming refrigerant, 2,3,3,3-tetrafluoro propene, or HFO-1234yf, has been successfully evaluated for automotive air conditioning, and is also being evaluated for stationary refrigeration and air conditioning systems. Due to the advantageous environmental properties of HFO-1234yf versus HFC-134a, coupled with its similar physical properties and system performance, HFO-1234yf is also being evaluated to replace HFC-134a in refrigeration applications where neat HFC-134a is currently used. This study reports on the development and validation of a sampling and analytical method for the determination of HFO-1234yf in air. Different collection media were screened for desorption and simulated sampling efficiency with three-section (350/350/350 mg) Anasorb CSC showing the best results. Therefore, air samples were collected using two 3-section Anasorb CSC sorbent tubes in series at 0.02 L/min for up to 8 hr for sample volumes of up to 9.6 L. The sorbent tubes were extracted in methylene chloride, and analyzed by gas chromatography with flame ionization detection. The method was validated from 0.1× to 20× the target level of 0.5 ppm (2.3 mg/m(3)) for a 9.6 L air volume. Desorption efficiencies for HFO-1234yf were 88 to 109% for all replicates over the validation range with a mean overall recovery of 93%. Simulated sampling efficiencies ranged from 87 to 104% with a mean of 94%. No migration or breakthrough to the back tube was observed under the sampling conditions evaluated. HFO-1234yf samples showed acceptable storage stability on Anasorb CSC sorbent up to a period of 30 days when stored under ambient, refrigerated, or frozen temperature conditions.

  5. Comparison of passive diffusion bag samplers and submersible pump sampling methods for monitoring volatile organic compounds in ground water at Area 6, Naval Air Station, Whidbey Island, Washington

    USGS Publications Warehouse

    Huffman, Raegan L.

    2002-01-01

    Ground-water samples were collected in April 1999 at Naval Air Station Whidbey Island, Washington, with passive diffusion samplers and a submersible pump to compare concentrations of volatile organic compounds (VOCs) in water samples collected using the two sampling methods. Single diffusion samplers were installed in wells with 10-foot screened intervals, and multiple diffusion samplers were installed in wells with 20- to 40-foot screened intervals. The diffusion samplers were recovered after 20 days and the wells were then sampled using a submersible pump. VOC concentrations in the 10-foot screened wells in water samples collected with diffusion samplers closely matched concentrations in samples collected with the submersible pump. Analysis of VOC concentrations in samples collected from the 20- to 40-foot screened wells with multiple diffusion samplers indicated vertical concentration variation within the screened interval, whereas the analysis of VOC concentrations in samples collected with the submersible pump indicated mixing during pumping. The results obtained using the two sampling methods indicate that the samples collected with the diffusion samplers were comparable with and can be considerably less expensive than samples collected using a submersible pump.

  6. Development of air sampling and analytical methods for toxic chlorinated organic compounds. Research report for 1,2-dichloropropane

    SciTech Connect

    Dillon, H.K.; Boyd, K.W.; Emory, M.B.

    1980-06-11

    Sampling and analytical methods for determining 1,2-dichloropropane (78875) (1,2-DCP) were evaluated. Detectors and columns were tested for suitability for chromatographic analysis. Various charcoals and other sorbents were tested for their capacity and desorption efficiency. An independent continuous organic vapor monitor was used to determine concentrations during the sampling studies. Petroleum charcoal was the most efficient collection medium, and acetone in cyclohexane was the most efficient desorbant. Gas chromatography with electrolytic conductivity was efficient for analysis. In tests over the concentration range of 0.124 to 128 milligrams per cubic meter, 1,2-DCP, the combination of petroleum charcoal, acetone in cyclohexane, and gas chromatography provided a 6.4% deviation for repeated measurements. Average recovery was 100%.

  7. Radon discrimination for work place air samples

    SciTech Connect

    Bratvold, T.

    1994-09-27

    Gross alpha/beta measurement systems are designed solely to identify an incident particle as either an alpha or a beta and register a count accordingly. The tool of choice for radon identification, via decay daughters, is an instrument capable of identifying the energy of incident alpha particles and storing that information separately from detected alpha emissions of different energy. In simpler terms, the desired instrument is an alpha spectroscopy system. K Basins Radiological Control (KBRC) procured an EG&G ORTEC OCTETE PC alpha spectroscopy system to facilitate radon identification on work place air samples. The alpha spectrometer allows for the identification of any alpha emitting isotope based on characteristic alpha emission energies. With this new capability, KBRC will explicitly know whether or not there exists a true airborne concern. Based on historical air quality data, this new information venue will reduce the use of respirators substantially. Situations where an area remains ``on mask`` due solely to the presence of radon daughters on the grab air filter will finally be eliminated. This document serves to introduce a new method for radon daughter detection at the 183KE Health Physics Analytical Laboratory (HPAL). A new work place air sampling analysis program will be described throughout this paper. There is no new technology being introduced, nor any unproven analytical process. The program defined over the expanse of this document simply explains how K Basins Radiological Control will employ their alpha spectrometer.

  8. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  9. Performances and application of a passive sampling method for the simultaneous determination of nitrogen dioxide and sulfur dioxide in ambient air.

    PubMed

    Plaisance, H; Sagnier, I; Saison, J Y; Galloo, J C; Guillermo, R

    2002-11-01

    The performances and applicability of a diffusion tube sampler for the simultaneous measurements of NO2 and SO2 in ambient air were evaluated. SO2 and NO2 are collected by the passive sampler using triethanolamine as trapping agent and are determined as sulphate and nitrite with ion chromatography. The detection limit (2.3 microg m(-3) of NO2 and 4.2 microg m(-3) of SO2 for two weeks sampling) is adequate for the determination of concentrations in urban and industrial areas. Precision of the method as RSD is in mean 5% for NO2 and 12% for SO2 at the concentration levels in urban areas. Calibration of the method was performed in the field conditions by comparison between the responses of sampler and the concentrations measured by the continuous monitors. High degree of linearity (correlation coefficients > 0.8) is found between the passive sampler tube and the continuous monitor data for both NO2 and SO2. To reduce the wind velocity influence on passive sampling of diffusion tubes, a protective shelter was tested in this study. The overall uncertainty of one measure for the optimised method is estimated at 5 microg m(-3) for NO2 and 6 microg m(-3) for SO2. Suitability of this passive sampling method for air pollution monitoring in urban areas was demonstrated by the results shown in this paper on a campaign carried out in the French agglomeration.

  10. Sampling system and method

    DOEpatents

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  11. Evaluation of sampling and analytical methods for nicotine and polynuclear aromatic hydrocarbon in indoor air. Final report, 1 February 1987-30 March 1987

    SciTech Connect

    Chuang, J.C.; Kuhlman, M.R.; Hannan, S.W.; Bridges, C.

    1987-11-01

    The objective of this project was to evaluate a potential collection medium, XAD-4 resin, for collecting nicotine and polynuclear aromatic hydrocarbon (PAH) and to determine whether one collection system and one analytical method will allow quantification of both compound classes in air. The extraction efficiency study was to determine the extraction method to quantitatively remove nicotine and PAH from XAD-4 resin. The results showed that a two-step Soxhlet extraction consisting of dichloromethane followed by ethyl acetate resulted in the best recoveries for both nicotine and PAH. In the sampling efficiency study, XAD-2 and XAD-4 resin were compared, in parallel, for collection of PAH and nicotine. Quartz fiber filters were placed upstream of both adsorbents to collect particles. Prior to sampling, both XAD-2 and XAD-4 traps were spiked with known amounts (2 microgram) of perdeuterated PAH and D3-nicotine. The experiments were performed with cigarette smoking and nonsmoking conditions. The spiked PAH were retained well in both adsorbents after exposure to more than 300 cu. m. of indoor air. The spiked XAD-4 resin gave higher recoveries for D3-nicotine than did the spiked XAD-2 resin. The collection efficiency for PAH for both adsorbents is very similar but higher levels of nicotine were collected on XAD-4 resin.

  12. Carbonaceous species methods comparison study at Citrus College. Task: analysis for trace hydrocarbons and related halocarbons in urban ambient air samples. Final report

    SciTech Connect

    Rasmussen, R.A.

    1987-10-01

    As part of the ARB-sponsored Carbonaceous Species Methods Comparison Study (CSMCS) in Glendora, CA, from August 11-21, 1986, time-integrated, ambient samples were collected in stainless steel canisters. Five samples per day were collected, ranging from 4 to 8 hours according to the CSMCS protocol. The species measured included CO, CH/sub 4/, CO/sub 2/, H/sub 2/, and the C/sub 2/ through C10 hydrocarbons. In addition, N/sub 2/O, the halocarbons F-12, F-11, F-113, CHCl/sub 3/, CH/sub 3/CCl/sub 3/, CCl/sub 4/, C/sub 2/HCl/sub 3/ and C/sub 2/Cl/sub 4/ were measured. Four gas-chromatograph systems were used to quantify these species. The report contains tables of concentrations of the species measured at the South Coast Air Basin site during smoggy summer conditions.

  13. East Mountain Area 1995 air sampling results

    SciTech Connect

    Deola, R.A.

    1996-09-01

    Ambient air samples were taken at two locations in the East Mountain Area in conjunction with thermal testing at the Lurance Canyon Burn Site (LCBS). The samples were taken to provide measurements of particulate matter with a diameter less than or equal to 10 micrometers (PM{sub 10}) and volatile organic compounds (VOCs). This report summarizes the results of the sampling performed in 1995. The results from small-scale testing performed to determine the potentially produced air pollutants in the thermal tests are included in this report. Analytical results indicate few samples produced measurable concentrations of pollutants believed to be produced by thermal testing. Recommendations for future air sampling in the East Mountain Area are also noted.

  14. Direct analysis of air filter samples for alpha emitting isotopes

    SciTech Connect

    Mohagheghi, A.H.; Ghanbari, F.; Ebara, S.B.; Enghauser, M.E.; Bakhtiar, S.N.

    1997-04-01

    The traditional method for determination of alpha emitting isotopes on air filters has been to process the samples by radiochemical methods. However, this method is too slow for cases of incidents involving radioactive materials where the determination of personnel received dose is urgent. A method is developed to directly analyze the air filters taken from personal and area air monitors. The site knowledge is used in combination with alpha spectral information to identify isotopes. A mathematical function is developed to estimate the activity for each isotope. The strengths and weaknesses of the method are discussed.

  15. Workplace air monitoring and sampling practices at DOE facilities

    SciTech Connect

    Swinth, K.L.; Kenoyer, J.L.; Selby, J.M.; Vallario, E.J.; Burphy, B.L.

    1986-03-01

    Current air monitoring and sampling practices at DOE facilities were surveyed as a part of an air monitoring upgrade task. A comprehensive questionnaire was developed and distributed to DOE contractors through the DOE field offices. Twenty-six facilities returned a completed questionnaire. Questionnaire replies indicate diversity in air sampling and monitoring practices among DOE facilities. The difference among the facilities exist in monitoring and sampling instrumentation, procedures, calibration, analytical methods, detection levels, and action levels. Many of these differences could be attributed to different operational needs.

  16. Evaluating Radionuclide Air Emission Stack Sampling Systems

    SciTech Connect

    Ballinger, Marcel Y.

    2002-12-16

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R&D) facilities for the U.S. Department of Energy at the Hanford Site, Washington. These facilities are subject to Clean Air Act regulations that require sampling of radionuclide air emissions from some of these facilities. A revision to an American National Standards Institute (ANSI) standard on sampling radioactive air emissions has recently been incorporated into federal and state regulations and a re-evaluation of affected facilities is being performed to determine the impact. The revised standard requires a well-mixed sampling location that must be demonstrated through tests specified in the standard. It also carries a number of maintenance requirements, including inspections and cleaning of the sampling system. Evaluations were performed in 2000 – 2002 on two PNNL facilities to determine the operational and design impacts of the new requirements. The evaluation included inspection and cleaning maintenance activities plus testing to determine if the current sampling locations meet criteria in the revised standard. Results show a wide range of complexity in inspection and cleaning activities depending on accessibility of the system, ease of removal, and potential impact on building operations (need for outages). As expected, these High Efficiency Particulate Air (HEPA)-filtered systems did not show deposition significant enough to cause concerns with blocking of the nozzle or other parts of the system. The tests for sampling system location in the revised standard also varied in complexity depending on accessibility of the sample site and use of a scale model can alleviate many issues. Previous criteria to locate sampling systems at eight duct diameters downstream and two duct diameters upstream of the nearest disturbances is no guarantee of meeting criteria in the revised standard. A computational fluid dynamics model was helpful in understanding flow and

  17. Method and apparatus for sampling atmospheric mercury

    DOEpatents

    Trujillo, Patricio E.; Campbell, Evan E.; Eutsler, Bernard C.

    1976-01-20

    A method of simultaneously sampling particulate mercury, organic mercurial vapors, and metallic mercury vapor in the working and occupational environment and determining the amount of mercury derived from each such source in the sampled air. A known volume of air is passed through a sampling tube containing a filter for particulate mercury collection, a first adsorber for the selective adsorption of organic mercurial vapors, and a second adsorber for the adsorption of metallic mercury vapor. Carbon black molecular sieves are particularly useful as the selective adsorber for organic mercurial vapors. The amount of mercury adsorbed or collected in each section of the sampling tube is readily quantitatively determined by flameless atomic absorption spectrophotometry.

  18. Presence of organophosphorus pesticide oxygen analogs in air samples

    PubMed Central

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2012-01-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (< 30 ng/m3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  19. Presence of organophosphorus pesticide oxygen analogs in air samples

    NASA Astrophysics Data System (ADS)

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2013-02-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (<30 ng m-3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  20. Innovations in air sampling to detect plant pathogens

    PubMed Central

    West, JS; Kimber, RBE

    2015-01-01

    Many innovations in the development and use of air sampling devices have occurred in plant pathology since the first description of the Hirst spore trap. These include improvements in capture efficiency at relatively high air-volume collection rates, methods to enhance the ease of sample processing with downstream diagnostic methods and even full automation of sampling, diagnosis and wireless reporting of results. Other innovations have been to mount air samplers on mobile platforms such as UAVs and ground vehicles to allow sampling at different altitudes and locations in a short space of time to identify potential sources and population structure. Geographical Information Systems and the application to a network of samplers can allow a greater prediction of airborne inoculum and dispersal dynamics. This field of technology is now developing quickly as novel diagnostic methods allow increasingly rapid and accurate quantifications of airborne species and genetic traits. Sampling and interpretation of results, particularly action-thresholds, is improved by understanding components of air dispersal and dilution processes and can add greater precision in the application of crop protection products as part of integrated pest and disease management decisions. The applications of air samplers are likely to increase, with much greater adoption by growers or industry support workers to aid in crop protection decisions. The same devices are likely to improve information available for detection of allergens causing hay fever and asthma or provide valuable metadata for regional plant disease dynamics. PMID:25745191

  1. Sampling system and method

    DOEpatents

    Decker, David L; Lyles, Brad F; Purcell, Richard G; Hershey, Ronald Lee

    2014-05-20

    An apparatus and method for supporting a tubing bundle during installation or removal. The apparatus includes a clamp for securing the tubing bundle to an external wireline. The method includes deploying the tubing bundle and wireline together, The tubing bundle is periodically secured to the wireline using a clamp.

  2. Air Sampling Instruments for Evaluation of Atmospheric Contaminants. Fourth Edition.

    ERIC Educational Resources Information Center

    American Conference of Governmental Industrial Hygienists, Cincinnati, OH.

    This text, a revision and extension of the first three editions, consists of papers discussing the basic considerations in sampling air for specific purposes, sampler calibration, systems components, sample collectors, and descriptions of air-sampling instruments. (BT)

  3. A simple novel device for air sampling by electrokinetic capture

    SciTech Connect

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the

  4. A simple novel device for air sampling by electrokinetic capture

    DOE PAGES

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of

  5. Air sampling of nickel in a refinery.

    PubMed

    Harmse, Johannes L; Engelbrecht, Jacobus C

    2007-08-01

    Air monitoring was conducted in a nickel base metal refinery to determine compliance with occupational exposure limits. The hypothesis stated that levels of airborne dust may pose a risk to worker health if compared to the relevant exposure limits. Exposure limits for nickel species are set for the inhalable nickel dust fraction. Personal air samples, representative of three selected areas were collected in the workers' breathing zones, using the Institute of Occupational Medicine (IOM) samplers. Real-time personal samples were collected randomly over a two-month period in three nickel production areas. Filter papers were treated gravimetrically and were analysed for soluble and insoluble nickel through inductive coupled plasma-mass spectrometry (ICP-MS). Measured concentrations were expressed as time weighted average exposure concentrations. Results were compared to South African occupational exposure limits (OELs) and to the threshold limit values (TLVs) set by the American Conference of Governmental Industrial Hygienists (ACGIH) to determine compliance. Statistical compliance was also determined using the National Institute for Occupational Safety and Health procedure as prescribed by South Africa's Hazardous Chemical Substances Regulations in 1995. In two of the areas it was found that exposure concentrations complied with the OELs. Some exposures exceeded the OEL values and most exposures exceeded the TLV values in the other area concerned. A comprehensive health risk assessment needs to be conducted to determine the cause of non-compliance. PMID:17613095

  6. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air... detect maximum concentrations of beryllium in the ambient air. (b) All monitoring sites shall be...

  7. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air... detect maximum concentrations of beryllium in the ambient air. (b) All monitoring sites shall be...

  8. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air... detect maximum concentrations of beryllium in the ambient air. (b) All monitoring sites shall be...

  9. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air... detect maximum concentrations of beryllium in the ambient air. (b) All monitoring sites shall be...

  10. Determination of natural resistance frequencies in Penicillium digitatum using a new air-sampling method and characterization of fludioxonil- and pyrimethanil-resistant isolates.

    PubMed

    Kanetis, L; Förster, H; Adaskaveg, J E

    2010-08-01

    ABSTRACT Fungicide resistance was identified in natural populations of Penicillium digitatum, the causal agent of green mold of citrus, to two of three new postharvest fungicides before their commercial use. Using a new air-sampling method where large populations of the pathogen in citrus packinghouses were exposed to agar plates with a continuous, wide-range fungicide concentration gradient, isolates with reduced sensitivity to fludioxonil or pyrimethanil were obtained. Resistance frequencies to fludioxonil and pyrimethanil were calculated as 9.5 x 10(-7) to 1.5 x 10(-5) and 7.3 x 10(-6) to 6.2 x 10(-5), respectively. No isolates resistant to azoxystrobin were detected. Isolates with reduced sensitivity to fludioxonil or pyrimethanil were also obtained in laboratory selection studies, where high concentrations of conidial mixtures of isolates sensitive to the three fungicides were plated onto agar amended with each fungicide at 10 microg/ml. Isolates obtained from fludioxonil selection plates in laboratory and packinghouse experiments were placed into two categories based on mycelial growth: moderately resistant isolates had 50% effective concentration (EC(50)) values of 0.1 to 0.82 microg/ml and highly resistant isolates had EC(50) values > 1.5 microg/ml. Isolates resistant to pyrimethanil all had EC(50) values >8 microg/ml. Representative isolates of the two categories with reduced sensitivity to fludioxonil varied widely in their virulence and sporulation capacity as measured by the incidence of decay and degree of sporulation on inoculated fruit, respectively, whereas pyrimethanil-resistant isolates were mostly similar to the wild-type isolate. Fungicide sensitivity characteristics for isolates from fludioxonil and pyrimethanil selection plates remained stable after passages on nonamended agar, and disease could not be controlled after treatment with the respective fungicides. Types of fungicide resistance were visualized on thiabendazole- (TBZ) and imazalil

  11. Diagnosing AIRS Sampling with CloudSat Cloud Classes

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric; Yue, Qing; Guillaume, Alexandre; Kahn, Brian

    2011-01-01

    AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.

  12. Minanre Gas Concentrators For Air Sampling

    SciTech Connect

    Dr. Seung Ho Hong

    2001-03-01

    The goal of this project was to demonstrate the feasibility of a compact, lightweight, gas-sampling device with rapid-cycle-time characteristics. The highlights of our Phase I work include: (1) Demonstration of a compact gas sampler with integrated heater. This device has an order of magnitude greater adsorption capacity and much faster heating/cooling times than commercial sorbent tubes. (2) Completion of computational fluid dynamics modeling of the gas sampler to determine airflow characteristics for various design options. These modeling efforts guided the development and testing of the Mesochannel Gas Sampler prototype. (3) Testing of the Mesochannel Gas Sampler in parallel with tests of two packed-bed samplers. These tests showed the Mesochannel Gas Sampler represents a substantial improvement compared with the packed-bed approach. Our mesochannel heat-exchanger/adsorber architecture allows very efficient use of adsorbent mass, high adsorbent loadings, and very low pressure drop, which makes possible very high air-sampling rates using a simple, low-power fan. This device is well-suited for collecting samples of trace-level contaminants. The integrated heater, which forms the adsorbent-coated mesochannel walls, allows direct heating of the adsorbent and results in very rapid desorption of the adsorbed species. We believe the Mesochannel Gas Sampler represents a promising technology for the improvement of trace-contaminant detection limits. In our Phase II proposal, we outline several improvements to the gas sampler that will further improve its performance.

  13. Monitoring air sampling in operating theatres: can particle counting replace microbiological sampling?

    PubMed

    Landrin, A; Bissery, A; Kac, G

    2005-09-01

    Microbiological contamination of air in the operating room is generally considered to be a risk factor for surgical site infections in clean surgery. Evaluation of the quality of air in operating theatres can be performed routinely by microbiological sampling and particle counting, but the relationship between these two methods has rarely been evaluated. The aim of this study was to determine whether particle counting could be predictive of microbiological contamination of air in operating rooms. Over a three-month period, air microbiological sampling and particle counting were performed simultaneously in four empty operating rooms belonging to two surgical theatres equipped with conventional ventilation via high-efficiency particulate air filters. Correlation between the two methods was measured with Spearman's correlation coefficient. The ability of particle counting to discriminate between microbiological counting values higher and lower than 5 colony-forming units (CFU)/m3 was evaluated using receiver-operating characteristic (ROC) analysis. Microbiological counting ranged from 0 to 38CFU/m3, while the particle counts ranged from 0 to 46 262/m3. Methods of microbiological and particle counting did not correlate (Spearman correlation coefficient=0.06, P=0.6). Using the ROC curve, no particle count value could be predictive of a microbiological count higher than 5CFU/m3. The results of the current study suggest that there is no reason to replace microbiological sampling with particle counting for routine evaluation of microbiological contamination in conventionally ventilated operating theatres.

  14. Sampling Interplanetary Dust Particles from Antarctic Air

    NASA Astrophysics Data System (ADS)

    Taylor, S.; Lever, J. H.; Alexander, C. M. O'D.; Brownlee, D. E.; Messenger, S.; Littler, L. R.; Stroud, R. M.; Wozniakiewicz, P.; Clement, S.

    2016-08-01

    We are undertaking a NASA and NSF supported project to filter large volumes of clean Antarctic air to collect a broad range of cosmic dust, including CP-IDPs, rare ultra-carbonaceous particles and particles derived from specific meteor streams.

  15. Sampling methods for phlebotomine sandflies.

    PubMed

    Alexander, B

    2000-06-01

    A review is presented of methods for sampling phlebotomine sandflies (Diptera: Psychodidae). Among approximately 500 species of Phlebotominae so far described, mostly in the New World genus Lutzomyia and the Old World genus Phlebotomus, about 10% are known vectors of Leishmania parasites or other pathogens. Despite being small and fragile, sandflies have a wide geographical range with species occupying a considerable diversity of ecotopes and habitats, from deserts to humid forests, so that suitable methods for collecting them are influenced by environmental conditions where they are sought. Because immature phlebotomines occupy obscure terrestrial habitats, it is difficult to find their breeding sites. Therefore, most trapping methods and sampling procedures focus on sandfly adults, whether resting or active. The diurnal resting sites of adult sandflies include tree holes, buttress roots, rock crevices, houses, animal shelters and burrows, from which they may be aspirated directly or trapped after being disturbed. Sandflies can be collected during their periods of activity by interception traps, or by using attractants such as bait animals, CO2 or light. The method of trapping used should: (a) be suited to the habitat and area to be surveyed, (b) take into account the segment of the sandfly population to be sampled (species, sex and reproduction condition) and (c) yield specimens of appropriate condition for the study objectives (e.g. identification of species present, population genetics or vector implication). Methods for preservation and transportation of sandflies to the laboratory also depend on the objectives of a particular study and are described accordingly. PMID:10872855

  16. A continuous sampling air-ICP for metals emission monitoring

    SciTech Connect

    Baldwin, D.P.; Zamzow, D.S.; Eckels, D.E.; Miller, G.P.

    1999-09-19

    An air-inductively coupled plasma (air-ICP) system has been developed for continuous sampling and monitoring of metals as a continuous emission monitor (CEM). The plasma is contained in a metal enclosure to allow reduced-pressure operation. The enclosure and plasma are operated at a pressure slightly less than atmospheric using a Roots blower, so that sample gas is continuously drawn into the plasma. A Teflon sampling chamber, equipped with a sampling pump, is connected to the stack that is to be monitored to isokinetically sample gas from the exhaust line and introduce the sample into the air-ICP. Optical emission from metals in the sampled gas stream is detected and monitored using an acousto-optic tunable filter (AOTF)--echelle spectrometer system. A description of the continuous sampling air-ICP system is given, along with some preliminary laboratory data for continuous monitoring of metals.

  17. Elaborating transition interface sampling methods

    SciTech Connect

    Erp, Titus S. van . E-mail: bolhuis@science.uva.nl

    2005-05-01

    We review two recently developed efficient methods for calculating rate constants of processes dominated by rare events in high-dimensional complex systems. The first is transition interface sampling (TIS), based on the measurement of effective fluxes through hypersurfaces in phase space. TIS improves efficiency with respect to standard transition path sampling (TPS) rate constant techniques, because it allows a variable path length and is less sensitive to recrossings. The second method is the partial path version of TIS. Developed for diffusive processes, it exploits the loss of long time correlation. We discuss the relation between the new techniques and the standard reactive flux methods in detail. Path sampling algorithms can suffer from ergodicity problems, and we introduce several new techniques to alleviate these problems, notably path swapping, stochastic configurational bias Monte Carlo shooting moves and order-parameter free path sampling. In addition, we give algorithms to calculate other interesting properties from path ensembles besides rate constants, such as activation energies and reaction mechanisms.

  18. Perfluorocarbon tracer method for air-infiltration measurements

    DOEpatents

    Dietz, R.N.

    1982-09-23

    A method of measuring air infiltration rates suitable for use in rooms of homes and buildings comprises the steps of emitting perfluorocarbons in the room to be measured, sampling the air containing the emitted perfluorocarbons over a period of time, and analyzing the samples at a laboratory or other facility.

  19. Venturi Air-Jet Vacuum Ejector For Sampling Air

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Burney, L. Garland; Wade, Larry O.

    1990-01-01

    Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

  20. A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

    PubMed

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. PMID:26014445

  1. A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

    PubMed

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples.

  2. Methods for Sampling of Airborne Viruses

    PubMed Central

    Verreault, Daniel; Moineau, Sylvain; Duchaine, Caroline

    2008-01-01

    Summary: To better understand the underlying mechanisms of aerovirology, accurate sampling of airborne viruses is fundamental. The sampling instruments commonly used in aerobiology have also been used to recover viruses suspended in the air. We reviewed over 100 papers to evaluate the methods currently used for viral aerosol sampling. Differentiating infections caused by direct contact from those caused by airborne dissemination can be a very demanding task given the wide variety of sources of viral aerosols. While epidemiological data can help to determine the source of the contamination, direct data obtained from air samples can provide very useful information for risk assessment purposes. Many types of samplers have been used over the years, including liquid impingers, solid impactors, filters, electrostatic precipitators, and many others. The efficiencies of these samplers depend on a variety of environmental and methodological factors that can affect the integrity of the virus structure. The aerodynamic size distribution of the aerosol also has a direct effect on sampler efficiency. Viral aerosols can be studied under controlled laboratory conditions, using biological or nonbiological tracers and surrogate viruses, which are also discussed in this review. Lastly, general recommendations are made regarding future studies on the sampling of airborne viruses. PMID:18772283

  3. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); Tang, Shoou-yu (Inventor); O'Brien, Martin (Inventor)

    2010-01-01

    Systems and methods for sensing air outside a moving aircraft are presented. In one embodiment, a system includes a laser for generating laser energy. The system also includes one or more transceivers for projecting the laser energy as laser radiation to the air. Subsequently, each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines one or more air parameters based on the scattered laser radiation. Such air parameters may include air speed, air pressure, air temperature and aircraft orientation angle, such as yaw, angle of attack and sideslip.

  4. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); O'Brien, Martin J. (Inventor); Weimer, Carl S. (Inventor); Nelson, Loren D. (Inventor)

    2005-01-01

    Systems and methods for sensing air outside a moving aircraft are presented. In one embodiment, a system includes a laser for generating laser energy. The system also includes one or more transceivers for projecting the laser energy as laser radiation to the air. Subsequently, each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines one or more air parameters based on the scattered laser radiation. Such air parameters may include air speed, air pressure, air temperature and aircraft orientation angle, such as yaw, angle of attack and sideslip.

  5. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); O'Brien, Martin J. (Inventor); Weimer, Carl S. (Inventor); Nelson, Loren D. (Inventor)

    2008-01-01

    Systems and methods for sensing air outside a moving aircraft are presented. In one embodiment, a system includes a laser for generating laser energy. The system also includes one or more transceivers for projecting the laser energy as laser radiation to the air. Subsequently, each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines one or more air parameters based on the scattered laser radiation. Such air parameters may include air speed, air pressure, air temperature and aircraft orientation angle, such as yaw, angle of attack and sideslip.

  6. In-mask aerosol sampling for powered air purifying respirators

    SciTech Connect

    Liu, B.Y.U.; Sega, K.; Rubow, K.L.; Lenhart, S.W.; Myers, W.R.

    1984-04-01

    A system for sampling aerosols in the facepiece of a powered air purifying respirator has been described. The system consists of a sampling inlet mounted on the respiratory facepiece, a filter cassette and a personal sampling pump. The theoretical and practical considerations leading to the design of the sampling inlet have been discussed and experimental data presented showing the efficiency of the inlet as a function of particle size and sampling flow rate. The in-mask sampling system has been designed for powered air purifying respirators.

  7. Evaluation of Urban Air Quality By Passive Sampling Technique

    NASA Astrophysics Data System (ADS)

    Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.

    Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many

  8. Soil separator and sampler and method of sampling

    DOEpatents

    O'Brien, Barry H [Idaho Falls, ID; Ritter, Paul D [Idaho Falls, ID

    2010-02-16

    A soil sampler includes a fluidized bed for receiving a soil sample. The fluidized bed may be in communication with a vacuum for drawing air through the fluidized bed and suspending particulate matter of the soil sample in the air. In a method of sampling, the air may be drawn across a filter, separating the particulate matter. Optionally, a baffle or a cyclone may be included within the fluidized bed for disentrainment, or dedusting, so only the finest particulate matter, including asbestos, will be trapped on the filter. The filter may be removable, and may be tested to determine the content of asbestos and other hazardous particulate matter in the soil sample.

  9. Stratospheric air sampling platform/sensor tradeoffs

    NASA Technical Reports Server (NTRS)

    Arno, R. D.; Page, W.

    1976-01-01

    Results of a study are described in which in-situ and remote sensing instrumentation are considered for accommodation on airborne platforms capable of reaching stratospheric altitudes. The instrumentation measures trace species of importance to present concerns regarding stratospheric pollution and possible ozone depletion. The platforms examined were the U-2, modified U-2, balloon, rocket, F-15 flown in a zoom-climb maneuver, YF-12, and remotely piloted vehicle (RPV). The sensors and performance characteristics of the platforms are described and special problems of sensor-platform integration are discussed. A typical latitudinal sampling mission is utilized to describe platform logistics problems and how the platforms might perform such missions.

  10. EML Surface Air Sampling Program, 1990--1993 data

    SciTech Connect

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

  11. Fluid sampling apparatus and method

    DOEpatents

    Yeamans, David R.

    1998-01-01

    Incorporation of a bellows in a sampling syringe eliminates ingress of contaminants, permits replication of amounts and compression of multiple sample injections, and enables remote sampling for off-site analysis.

  12. Fluid sampling apparatus and method

    DOEpatents

    Yeamans, D.R.

    1998-02-03

    Incorporation of a bellows in a sampling syringe eliminates ingress of contaminants, permits replication of amounts and compression of multiple sample injections, and enables remote sampling for off-site analysis. 3 figs.

  13. Efficiency of dust sampling inlets in calm air.

    PubMed

    Breslin, J A; Stein, R L

    1975-08-01

    Measurement of airborne dust concentrations usually involves drawing a sample of the dust-laden air into the measuring instrument through an inlet. Even if the surrounding air is calm, theoretical calculations predict that large particles may not be sampled accurately due to the combined effects of gravity and inertia on the particles near the sampling inlet. Tests were conducted to determine the conditions of particle size, inlet radius, and flow rare necessary for accurate dust sampling. A coal-dust aerosol was sampled simultaneously through inlets of different diameters at the same volume flow-rate and collected on filters. The dust was removed from the filters and the particles were counted and sized with a Coulter counter. Results showed that published criteria for inlet conditions for correct sampling are overly restrictive and that respirable-size particles are sampled correctly in the normal range or operation of most dust sampling instruments. PMID:1227283

  14. Sampling of air streams and incorporation of samples in the Microtox{trademark} toxicity testing system

    SciTech Connect

    Kleinheinz, G.T.; St. John, W.P.

    1997-10-01

    A study was conducted to develop a rapid and reliable method for the collection and incorporation of biofiltration air samples containing volatile organic compounds (VOCs) into the Microtox toxicity testing system. To date, no method exists for this type of assay. A constant stream of VOCs was generated by air stripping compounds from a complex mixture of petroleum hydrocarbons (PHCs). Samples were collected on coconut charcoal ORBO tubes and the VOCs extracted with methylene chloride. The compounds extracted were then solvent exchanged into dimethyl sulfoxide (DMSO) under gaseous nitrogen. The resulting DMSO extract was directly incorporated into the Microtox toxicity testing system. In order to determine the efficiency of the solvent exchange, the VOCs in the DMSO extract were then extracted into hexane and subsequently analyzed using gas chromatography (GC) with a flame ionization detector (FID). It was determined that all but the most volatile VOCs could be effectively transferred from the ORBO tubes to DMSO for Microtox testing. Potential trace amounts of residual methylene chloride in the DMSO extracts showed no adverse effects in the Microtox system when compared to control samples.

  15. Concepts for Environmental Radioactive Air Sampling and Monitoring

    SciTech Connect

    Barnett, J. Matthew

    2011-11-04

    Environmental radioactive air sampling and monitoring is becoming increasingly important as regulatory agencies promulgate requirements for the measurement and quantification of radioactive contaminants. While researchers add to the growing body of knowledge in this area, events such as earthquakes and tsunamis demonstrate how nuclear systems can be compromised. The result is the need for adequate environmental monitoring to assure the public of their safety and to assist emergency workers in their response. Two forms of radioactive air monitoring include direct effluent measurements and environmental surveillance. This chapter presents basic concepts for direct effluent sampling and environmental surveillance of radioactive air emissions, including information on establishing the basis for sampling and/or monitoring, criteria for sampling media and sample analysis, reporting and compliance, and continual improvement.

  16. Comparison of ultrasound-enhanced air-assisted liquid-liquid microextraction and low-density solvent-based dispersive liquid-liquid microextraction methods for determination of nonsteroidal anti-inflammatory drugs in human urine samples.

    PubMed

    Barfi, Behruz; Asghari, Alireza; Rajabi, Maryam; Goochani Moghadam, Ahmad; Mirkhani, Nasim; Ahmadi, Farhad

    2015-01-01

    Two dispersive-based liquid-liquid microextraction methods including ultrasound-enhanced air-assisted liquid-liquid microextraction (USE-AALLME) and low-density solvent-based dispersive liquid-liquid microextraction (LDS-DLLME) were compared for the extraction of salicylic acid (the hydrolysis product of acetylsalicylic acid), diclofenac and ibuprofen, as instances of the most commonly used nonsteroidal anti-inflammatory drugs (NSAIDs), in human urine prior to their determination by gas chromatography with flame ionization detection (GC-FID). The influence of different parameters affecting the USE-AALLME (including type and volume of the extraction solvent, sample pH, ionic strength, and simultaneous sonication and number of extraction cycles) and the LDS-DLLME (including type and volume of the extraction and disperser solvents, sample pH, and ionic strength) were investigated to optimize their extraction efficiencies. Both methods are fast, simple and convenient with organic solvent consumption at μL level. However, the best results were obtained using the USE-AALLME method, applying 30 μL of 1-octanol as extraction solvent, 5.0 mL of sample at pH 3.0, without salt addition, and 5 extraction cycles during 20s of sonication. This method was validated based on linearities (r(2) >0 .971), limits of detection (0.1-1.0 μg L(-1)), linear dynamic ranges (0.4-1000.0 μg L(-1)), enrichment factors (115 ± 3-135 ± 3), consumptive indices (0.043-0.037), inter- and intra-day precisions (4.3-4.8 and 5.6-6.1, respectively), and relative recoveries (94-103%). The USE-AALLME in combination with GC-FID, and with no need to derivatization step, was demonstrated to be a simple, inexpensive, sensitive and efficient method to determine NSAIDs in human urine samples.

  17. Low-cost monitoring of Campylobacter in poultry houses by air sampling and quantitative PCR.

    PubMed

    Søndergaard, M S R; Josefsen, M H; Löfström, C; Christensen, L S; Wieczorek, K; Osek, J; Hoorfar, J

    2014-02-01

    The present study describes the evaluation of a method for the quantification of Campylobacter by air sampling in poultry houses. Sampling was carried out in conventional chicken houses in Poland, in addition to a preliminary sampling in Denmark. Each measurement consisted of three air samples, two standard boot swab fecal samples, and one airborne particle count. Sampling was conducted over an 8-week period in three flocks, assessing the presence and levels of Campylobacter in boot swabs and air samples using quantitative real-time PCR. The detection limit for air sampling was approximately 100 Campylobacter cell equivalents (CCE)/m3. Airborne particle counts were used to analyze the size distribution of airborne particles (0.3 to 10 μm) in the chicken houses in relation to the level of airborne Campylobacter. No correlation was found. Using air sampling, Campylobacter was detected in the flocks right away, while boot swab samples were positive after 2 weeks. All samples collected were positive for Campylobacter from week 2 through the rest of the rearing period for both sampling techniques, although levels 1- to 2-log CCE higher were found with air sampling. At week 8, the levels were approximately 10(4) and 10(5) CCE per sample for boot swabs and air, respectively. In conclusion, using air samples combined with quantitative real-time PCR, Campylobacter contamination could be detected earlier than by boot swabs and was found to be a more convenient technique for monitoring and/or to obtain enumeration data useful for quantitative risk assessment of Campylobacter.

  18. Duplex sampling apparatus and method

    DOEpatents

    Brown, Paul E.; Lloyd, Robert

    1992-01-01

    An improved apparatus is provided for sampling a gaseous mixture and for measuring mixture components. The apparatus includes two sampling containers connected in series serving as a duplex sampling apparatus. The apparatus is adapted to independently determine the amounts of condensable and noncondensable gases in admixture from a single sample. More specifically, a first container includes a first port capable of selectively connecting to and disconnecting from a sample source and a second port capable of selectively connecting to and disconnecting from a second container. A second container also includes a first port capable of selectively connecting to and disconnecting from the second port of the first container and a second port capable of either selectively connecting to and disconnecting from a differential pressure source. By cooling a mixture sample in the first container, the condensable vapors form a liquid, leaving noncondensable gases either as free gases or dissolved in the liquid. The condensed liquid is heated to drive out dissolved noncondensable gases, and all the noncondensable gases are transferred to the second container. Then the first and second containers are separated from one another in order to separately determine the amount of noncondensable gases and the amount of condensable gases in the sample.

  19. Sampling and Analyzing Air Pollution: An Apparatus Suitable for Use in Schools.

    ERIC Educational Resources Information Center

    Rockwell, Dean M.; Hansen, Tony

    1994-01-01

    Describes two variations of an air sampler and analyzer that are inexpensive to construct, easy to operate, and designed to be used in an educational program. Variations use vacuum cleaners and aquarium pumps, and white facial tissues serve as filters. Samples of air pollution obtained by this method may be used from early grade school to advanced…

  20. Air-assisted liquid-liquid microextraction-gas chromatography-flame ionisation detection: a fast and simple method for the assessment of triazole pesticides residues in surface water, cucumber, tomato and grape juices samples.

    PubMed

    Farajzadeh, Mir Ali; Khoshmaram, Leila

    2013-12-01

    A recently reported microextraction technique namely air-assisted liquid-liquid microextraction (AALLME) has been described for the extraction/preconcentration of some triazole pesticides from different samples prior to gas chromatography-flame ionisation detection (GC-FID). This technique is similar to dispersive liquid-liquid microextraction (DLLME) but in this method there is no need to use a disperser solvent and also volume of the used extraction solvent is less than DLLME. In this study, toluene with a density lower than that of water was used as an extraction solvent. Under the optimum extraction conditions, the method showed wide linear ranges with R(2)>0.996 and low limits of detection and quantification between 0.53-1.13 and 1.76-3.77 ng mL(-1), respectively. Enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 713-808 and 100-113%, respectively. Relative standard deviations (RSDs) for the extraction of 25 and 250 ng mL(-1) of each selected triazole pesticide were less than 7% for intra-day (n=6) and inter-days (n=5) precision. The method was successfully used for analytes determination in different surface water, grape juice, cucumber, and tomato samples.

  1. Air sampling to recover variola virus in the environment of a smallpox hospital.

    PubMed

    MEIKLEJOHN, G; KEMPE, C H; DOWNIE, A W; BERGE, T O; ST VINCENT, L; RAO, A R

    1961-01-01

    The view is widely held that variola is highly infectious, and it was therefore thought of interest to obtain precise information on the amount of virus disseminated in the air by smallpox patients at various stages of their illness. To this end, measured samples of air in and around the smallpox wards of the Infectious Diseases Hospital, Madras, were tested for the presence of variola virus. Surprisingly, virus was recovered on one occasion only by the air sampling device used. All other tests were negative although large volumes of air were sampled in close proximity to patients at various stages of the disease. The authors consider that further observations should be made with more sensitive air sampling methods.

  2. Field evaluation of a VOST sampling method

    SciTech Connect

    Jackson, M.D.; Johnson, L.D.; Fuerst, R.G.; McGaughey, J.F.; Bursey, J.T.; Merrill, R.G.

    1994-12-31

    The VOST (SW-846 Method 0030) specifies the use of Tenax{reg_sign} and a particular petroleum-based charcoal (SKC Lot 104, or its equivalent), that is no longer commercially available. In field evaluation studies of VOST methodology, a replacement petroleum-based charcoal has been used: candidate replacement sorbents for charcoal were studied, and Anasorb{reg_sign} 747, a carbon-based sorbent, was selected for field testing. The sampling train was modified to use only Anasorb{reg_sign} in the back tube and Tenax{reg_sign} in the two front tubes to avoid analytical difficulties associated with the analysis of the sequential bed back tube used in the standard VOST train. The standard (SW-846 Method 0030) and the modified VOST methods were evaluated at a chemical manufacturing facility using a quadruple probe system with quadruple trains. In this field test, known concentrations of the halogenated volatile organic compounds, that are listed in the Clean Air Act Amendments of 1990, Title 3, were introduced into the VOST train and the modified VOST train, using the same certified gas cylinder as a source of test compounds. Statistical tests of the comparability of methods were performed on a compound-by-compound basis. For most compounds, the VOST and modified VOST methods were found to be statistically equivalent.

  3. DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS

    SciTech Connect

    Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

    2012-09-20

    Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected

  4. Apparatus and method for handheld sampling

    DOEpatents

    Staab, Torsten A.

    2005-09-20

    The present invention includes an apparatus, and corresponding method, for taking a sample. The apparatus is built around a frame designed to be held in at least one hand. A sample media is used to secure the sample. A sample media adapter for securing the sample media is operated by a trigger mechanism connectively attached within the frame to the sample media adapter.

  5. Soil sampling kit and a method of sampling therewith

    DOEpatents

    Thompson, C.V.

    1991-02-05

    A soil sampling device and a sample containment device for containing a soil sample is disclosed. In addition, a method for taking a soil sample using the soil sampling device and soil sample containment device to minimize the loss of any volatile organic compounds contained in the soil sample prior to analysis is disclosed. The soil sampling device comprises two close fitting, longitudinal tubular members of suitable length, the inner tube having the outward end closed. With the inner closed tube withdrawn a selected distance, the outer tube can be inserted into the ground or other similar soft material to withdraw a sample of material for examination. The inner closed end tube controls the volume of the sample taken and also serves to eject the sample. The soil sample containment device has a sealing member which is adapted to attach to an analytical apparatus which analyzes the volatile organic compounds contained in the sample. The soil sampling device in combination with the soil sample containment device allows an operator to obtain a soil sample containing volatile organic compounds and minimizing the loss of the volatile organic compounds prior to analysis of the soil sample for the volatile organic compounds. 11 figures.

  6. Soil sampling kit and a method of sampling therewith

    DOEpatents

    Thompson, Cyril V.

    1991-01-01

    A soil sampling device and a sample containment device for containing a soil sample is disclosed. In addition, a method for taking a soil sample using the soil sampling device and soil sample containment device to minimize the loss of any volatile organic compounds contained in the soil sample prior to analysis is disclosed. The soil sampling device comprises two close fitting, longitudinal tubular members of suitable length, the inner tube having the outward end closed. With the inner closed tube withdrawn a selected distance, the outer tube can be inserted into the ground or other similar soft material to withdraw a sample of material for examination. The inner closed end tube controls the volume of the sample taken and also serves to eject the sample. The soil sample containment device has a sealing member which is adapted to attach to an analytical apparatus which analyzes the volatile organic compounds contained in the sample. The soil sampling device in combination with the soil sample containment device allow an operator to obtain a soil sample containing volatile organic compounds and minimizing the loss of the volatile organic compounds prior to analysis of the soil sample for the volatile organic compounds.

  7. Air sampling and analysis in a rubber vulcanization area.

    PubMed

    Rappaport, S M; Fraser, D A

    1977-05-01

    Results of sampling and analysis of air in a rubber vulcanization area are described. Organic compounds were collected on activated charcoal, desorbed with carbon disulfide and analyzed by gas chromatography. Several previously identified substances were quantitated, including styrene, toluene, ethylbenzene, and several oligomers of 1,3-butadiene. Concentrations ranged from 0.007 to 1.1 ppm.

  8. Air sampling of mold spores by slit impactors: yield comparison.

    PubMed

    Pityn, Peter J; Anderson, James

    2013-01-01

    The performance of simple slit impactors for air sampling of mold contamination was compared under field conditions. Samples were collected side-by-side, outdoors in quadruplicates with Burkhard (ambient sampler) and Allergenco MK3 spore traps and with two identical Allergenco slit cassettes operated at diverse flow rates of 5 and 15 L/min, respectively. The number and types of mold spores in each sample were quantified by microscopy. Results showed all four single-stage slit impactors produced similar spore yields. Moreover, paired slit cassettes produced similar outcomes despite a three-fold difference in their sampling rate. No measurable difference in the amount or mix of mold spores per m(3)of air was detected. The implications for assessment of human exposures and interpretation of indoor/outdoor fungal burden are discussed. These findings demonstrate that slit cassettes capture most small spores, effectively and without bias, when operated at a range of flow rates including the lower flow rates used for personal sampling. Our findings indicate sampling data for mold spores correlate for different single stage impactor collection methodologies and that data quality is not deteriorated by operating conditions deviating from manufacturers' norms allowing such sampling results to be used for scientific, legal, investigative, or property insurance purposes. The same conclusion may not be applied to other particle sampling instruments and mulit-stage impactors used for ambient particulate sampling, which represent an entirely different scenario. This knowledge may help facilitate comparison between scientific studies where methodological differences exist.

  9. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); Tang, Shoou-yu (Inventor); Acott, Phillip E. (Inventor); Spaeth, Lisa G. (Inventor); O'Brien, Martin (Inventor)

    2011-01-01

    Systems and methods for sensing air includes at least one, and in some embodiments three, transceivers for projecting the laser energy as laser radiation to the air. The transceivers are scanned or aligned along several different axes. Each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines air temperatures, wind speeds, and wind directions based on the scattered laser radiation. Applications of the system to wind power site evaluation, wind turbine control, traffic safety, general meteorological monitoring and airport safety are presented.

  10. Compendium of methods for the determination of air pollutants in indoor air

    SciTech Connect

    Winberry, W.T.; Forehand, L.; Murphy, N.T.; Ceroli, A.; Phinney, B.

    1990-04-01

    Determination of pollutants in indoor air is a complex task because of the wide variety of compounds of interest and the lack of standardized sampling and analysis procedures. To assist agencies and persons responsible for sampling and analysis of indoor pollutants, the methods compendium provides current, technically-reviewed sampling and analysis procedures in a standardized format for determination of selected pollutants of primary importance in indoor air. Each chapter contains one or more active or passive sampling procedures along with one or more appropriate analytical procedures. The ten chapters of the compendium cover determination of volatile organic compounds, nicotine, carbon monoxide and carbon dioxide, air exchange rate, nitrogen dioxide, formaldehyde, benzo(a)pyrene and other polynuclear aromatic hydrocarbons, acid gases and aerosols, particulate matter, and pesticides. As further advancements are made, the procedures may be modified or updated, or additional methods may be added as appropriate.

  11. Marine Technician's Handbook, Instructions for Taking Air Samples on Board Ship: Carbon Dioxide Project.

    ERIC Educational Resources Information Center

    Keeling, Charles D.

    This booklet is one of a series intended to provide explicit instructions for the collection of oceanographic data and samples at sea. The methods and procedures described have been used by the Scripps Institution of Oceanography and found reliable and up-to-date. Instructions are given for taking air samples on board ship to determine the…

  12. Duplex sampling apparatus and method

    SciTech Connect

    Brown, P.E.; Lloyd, R.

    1992-07-07

    This patent describes a method of measuring the condensable vapor content and the noncondensable gaseous content of a mixture of condensable vapors and noncondensable gases. It comprises collecting a quantity of a mixture of condensable vapors and noncondensable gases in a first container, cooling the first container whereby the condensable vapors in the mixture are condensed, transferring the noncondensable gases from the first container to a downstream second container, determining the quantity of condensable vapors retained in the first container, and measuring the pressure of noncondensable gases in the second container, measuring the temperature of noncondensable gases in the second container, thereby determining the quantity of noncondensable gases in the second container from the temperature, pressure and volume, using the ideal gas law: P{sub v} = nRT, whereby the ratio of condensable vapors to noncondensable gases in the mixture is determined.

  13. Airing method-specific advertisements.

    PubMed

    Yaser, Y

    1992-06-01

    The Turkish Family Health and Planning Foundation initiated the commercial marketing of contraceptives in 1989 as part of a Contraceptive Social Marketing (CSM) program to make available low-cost contraceptives. In 1988 modern methods were used by 31% and traditional methods by 32.3%, while 36.6% used no contraceptives. Only 6.2% were current pill users mainly because of health reasons since high-dose pills dominated the market. A 1990 survey among urban consumers indicated a 94% awareness of contraceptive methods, 76.1% of current use, and preference for the IUD. The side effects of the pill were cited for disliking it, and the condom was rated higher. The CSM project aims at popularizing low-dose pills by explaining the differences and benefits regarding high-dose pills. It collaborated with manufacturers: Schering, Wyeth, Organon, and Eczacibasi Ilac. In 1991 a TV and radio advertisement campaign started that involves the low-dose products Microgynon, Triquilar, Desolet, Lo-Ovral, and Tri-Nordial. The introduction of the Okey condom by Eczacibasi Ilac. In June 1991 also entailed extensive promotion with newspaper ads and TV spots after getting official permission. 1.3 million condoms were sold in the 1st 2 months in 13,000 retail outlets, and 4 million more were projected to be sold. A shift of the attitude of supermarket owners allowing stocking of condoms and the support of the Turkish Ministry of Health, USAID, and the Turkish Radio and Television Bureau has facilitated the CSM project implementation that will profoundly affect family planning in Turkey.

  14. Airing method-specific advertisements.

    PubMed

    Yaser, Y

    1992-06-01

    The Turkish Family Health and Planning Foundation initiated the commercial marketing of contraceptives in 1989 as part of a Contraceptive Social Marketing (CSM) program to make available low-cost contraceptives. In 1988 modern methods were used by 31% and traditional methods by 32.3%, while 36.6% used no contraceptives. Only 6.2% were current pill users mainly because of health reasons since high-dose pills dominated the market. A 1990 survey among urban consumers indicated a 94% awareness of contraceptive methods, 76.1% of current use, and preference for the IUD. The side effects of the pill were cited for disliking it, and the condom was rated higher. The CSM project aims at popularizing low-dose pills by explaining the differences and benefits regarding high-dose pills. It collaborated with manufacturers: Schering, Wyeth, Organon, and Eczacibasi Ilac. In 1991 a TV and radio advertisement campaign started that involves the low-dose products Microgynon, Triquilar, Desolet, Lo-Ovral, and Tri-Nordial. The introduction of the Okey condom by Eczacibasi Ilac. In June 1991 also entailed extensive promotion with newspaper ads and TV spots after getting official permission. 1.3 million condoms were sold in the 1st 2 months in 13,000 retail outlets, and 4 million more were projected to be sold. A shift of the attitude of supermarket owners allowing stocking of condoms and the support of the Turkish Ministry of Health, USAID, and the Turkish Radio and Television Bureau has facilitated the CSM project implementation that will profoundly affect family planning in Turkey. PMID:12285550

  15. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); Tang, Shoou-Yu (Inventor); O'Brien, Martin J. (Inventor)

    2011-01-01

    A method for remotely sensing air outside a moving aircraft includes generating laser radiation within a swept frequency range. A portion of the laser radiation is projected from the aircraft into the air to induce scattered laser radiation. Filtered scattered laser radiation, filtered laser radiation, and unfiltered laser radiation are detected. At least one actual ratio is determined from data corresponding to the filtered scattered laser radiation and the unfiltered laser radiation. One or more air parameters are determined by correlating the actual ratio to at least one reference ratio.

  16. Optical air data systems and methods

    NASA Technical Reports Server (NTRS)

    Caldwell, Loren M. (Inventor); Tang, Shoou-Yu (Inventor); O'Brien, Martin J. (Inventor)

    2009-01-01

    A method for remotely sensing air outside a moving aircraft includes generating laser radiation within a swept frequency range. A portion of the laser radiation is projected from the aircraft into the air to induce scattered laser radiation. Filtered scattered laser radiation, filtered laser radiation, and unfiltered laser radiation are detected. At least one actual ratio is determined from data corresponding to the filtered scattered laser radiation and the unfiltered laser radiation. One or more air parameters are determined by correlating the actual ratio to at least one reference ratio.

  17. ASTM Validates Air Pollution Test Methods

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  18. Subrandom methods for multidimensional nonuniform sampling.

    PubMed

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics.

  19. Subrandom methods for multidimensional nonuniform sampling

    NASA Astrophysics Data System (ADS)

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics.

  20. Formal Methods Applications in Air Transportation

    NASA Technical Reports Server (NTRS)

    Farley, Todd

    2009-01-01

    The U.S. air transportation system is the most productive in the world, moving far more people and goods than any other. It is also the safest system in the world, thanks in part to its venerable air traffic control system. But as demand for air travel continues to grow, the air traffic control system s aging infrastructure and labor-intensive procedures are impinging on its ability to keep pace with demand. And that impinges on the growth of our economy. Air traffic control modernization has long held the promise of a more efficient air transportation system. Part of NASA s current mission is to develop advanced automation and operational concepts that will expand the capacity of our national airspace system while still maintaining its excellent record for safety. It is a challenging mission, as efforts to modernize have, for decades, been hamstrung by the inability to assure safety to the satisfaction of system operators, system regulators, and/or the traveling public. In this talk, we ll provide a brief history of air traffic control, focusing on the tension between efficiency and safety assurance, and the promise of formal methods going forward.

  1. Method and apparatus for data sampling

    DOEpatents

    Odell, Daniel M. C.

    1994-01-01

    A method and apparatus for sampling radiation detector outputs and determining event data from the collected samples. The method uses high speed sampling of the detector output, the conversion of the samples to digital values, and the discrimination of the digital values so that digital values representing detected events are determined. The high speed sampling and digital conversion is performed by an A/D sampler that samples the detector output at a rate high enough to produce numerous digital samples for each detected event. The digital discrimination identifies those digital samples that are not representative of detected events. The sampling and discrimination also provides for temporary or permanent storage, either serially or in parallel, to a digital storage medium.

  2. Method and apparatus for data sampling

    DOEpatents

    Odell, D.M.C.

    1994-04-19

    A method and apparatus for sampling radiation detector outputs and determining event data from the collected samples is described. The method uses high speed sampling of the detector output, the conversion of the samples to digital values, and the discrimination of the digital values so that digital values representing detected events are determined. The high speed sampling and digital conversion is performed by an A/D sampler that samples the detector output at a rate high enough to produce numerous digital samples for each detected event. The digital discrimination identifies those digital samples that are not representative of detected events. The sampling and discrimination also provides for temporary or permanent storage, either serially or in parallel, to a digital storage medium. 6 figures.

  3. Ambient Air Sampling During Quantum-dot Spray Deposition

    SciTech Connect

    Jankovic, John Timothy; Hollenbeck, Scott M

    2010-01-01

    Ambient air sampling for nano-size particle emissions was performed during spot spray coating operations with a Sono-Tek Exactacoat Benchtop system (ECB). The ECB consisted of the application equipment contained within an exhaust enclosure. The enclosure contained numerous small access openings, including an exhaust hook-up. Door access comprised most of the width and height of the front. The door itself was of the swing-out type. Two types of nanomaterials, Cadmium selenide (Cd-Se) quantum-dots (QDs) and Gold (Au) QDs, nominally 3.3 and 5 nm in diameter respectively, were applied during the evaluation. Median spray drop size was in the 20 to 60 micrometer size range.1 Surface coating tests were of short duration, on the order of one-half second per spray and ten spray applications between door openings. The enclosure was ventilated by connection to a high efficiency particulate aerosol (HEPA) filtered house exhaust system. The exhaust rate was nominally 80 ft3 per minute producing about 5 air changes per minute. Real time air monitoring with a scanning mobility particle size analyzer (SMPS ) with a size detection limit of 7 nm indicated a significant increase in the ambient air concentration upon early door opening. A handheld condensation particle counter (CPC) with a lower size limit of 10 nm did not record changes in the ambient background. This increase in the ambient was not observed when door opening was delayed for 2 minutes (~10 air changes). The ventilated enclosure controlled emissions except for cases of rapid door opening before the overspray could be removed by the exhaust. A time delay sufficient to provide 10 enclosure air changes (a concentration reduction of more than 99.99 %) before door opening prevented the release of aerosol particles in any size.2 Scanning-transmission electron microscopy (STEM) and atomic force microscopy (AFM) demonstrated the presence of agglomerates in the surfaces of the spray applied deposition. A filtered air sample of

  4. Passive air sampling of gaseous elemental mercury: a critical review

    NASA Astrophysics Data System (ADS)

    McLagan, David S.; Mazur, Maxwell E. E.; Mitchell, Carl P. J.; Wania, Frank

    2016-03-01

    Because gaseous elemental mercury (GEM) is distributed globally through the atmosphere, reliable means of measuring its concentrations in air are important. Passive air samplers (PASs), designed to be cheap, simple to operate, and to work without electricity, could provide an alternative to established active sampling techniques in applications such as (1) long-term monitoring of atmospheric GEM levels in remote regions and in developing countries, (2) atmospheric mercury source identification and characterization through finely resolved spatial mapping, and (3) the recording of personal exposure to GEM. An effective GEM PAS requires a tightly constrained sampling rate, a large and stable uptake capacity, and a sensitive analytical technique. None of the GEM PASs developed to date achieve levels of accuracy and precision sufficient for the reliable determination of background concentrations over extended deployments. This is due to (1) sampling rates that vary due to meteorological factors and manufacturing inconsistencies, and/or (2) an often low, irreproducible and/or unstable uptake capacity of the employed sorbents. While we identify shortcomings of existing GEM PAS, we also reveal potential routes to overcome those difficulties. Activated carbon and nanostructured metal surfaces hold promise as effective sorbents. Sampler designs incorporating diffusive barriers should be able to notably reduce the influence of wind on sampling rates.

  5. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  6. Mixed Methods Sampling: A Typology with Examples

    ERIC Educational Resources Information Center

    Teddlie, Charles; Yu, Fen

    2007-01-01

    This article presents a discussion of mixed methods (MM) sampling techniques. MM sampling involves combining well-established qualitative and quantitative techniques in creative ways to answer research questions posed by MM research designs. Several issues germane to MM sampling are presented including the differences between probability and…

  7. Sampling and analysis of terpenes in air. An interlaboratory comparison

    NASA Astrophysics Data System (ADS)

    Larsen, Bo; Bomboi-Mingarro, Teresa; Brancaleoni, Enzo; Calogirou, Aggelos; Cecinato, Angelo; Coeur, Cecile; Chatzinestis, Ioannis; Duane, Matthew; Frattoni, Massimiliano; Fugit, Jean-Luc; Hansen, Ute; Jacob, Veronique; Mimikos, Nikolaos; Hoffmann, Thorsten; Owen, Susan; Perez-Pastor, Rosa; Reichmann, Andreas; Seufert, Gunther; Staudt, Michael; Steinbrecher, Rainer

    An interlaboratory comparison on the sampling and analysis of terpenes in air was held within the framework of the BEMA (Biogenic Emissions in the Mediterranean Area) project in May 1995. Samples were drawn and analysed by 10 European laboratories from a dynamic artificial air generator in which five terpenes were present at low ng ℓ -1 levels and ozone varied between 8 and 125 ppbv. Significant improvements over previous inter-comparison exercises in the quality of results were observed. At the ozone mixing ratio of 8 ppbv a good agreement among laboratories was obtained for all test compounds with mean values close to the target concentration. At higher mixing ratios, ozone reduced terpene recoveries and decreased the precision of the measurements due to ozonolysis during sampling. For β-pinene this effect was negligible but for the more reactive compounds significant losses were observed in some laboratories ( cis-β-ocimene = trans-β-ocimene > linalool > d-limonene). The detrimental effect of ozone was significantly lower for the laboratories which removed ozone prior to sampling by scrubbers. Parallel sampling was carried out with a standardised sampler and each individual laboratory's own device. A good agreement between the two sets of results was obtained, clearly showing that the majority of laboratories used efficient sampling systems. Two different standard solutions were analysed by each laboratory. Only in a few cases did interference in the GC separation cause problems for the quantification of the terpenes (nonanal/linalool). However, making up of standards for the calibration of the analytical equipment (GC-MS or GC-FID) was pointed out as a source of error in some laboratories.

  8. Relative Humidity and its Effect on Sampling and Analysis of Agricultural Odorants in Air

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Source and ambient air sampling techniques used in agricultural air quality studies are seldom validated for the variability in the air matrix (temperature, dust levels, and relative humidity). In particular, relative humidity (RH) affects both field sampling and analysis of air samples. The objec...

  9. Survey of volatile organic compounds found in indoor and outdoor air samples from Japan.

    PubMed

    Tanaka-Kagawa, Toshiko; Uchiyama, Shigehisa; Matsushima, Erika; Sasaki, Akira; Kobayashi, Hiroshi; Kobayashi, Hiromi; Yagi, Masahiro; Tsuno, Masahiko; Arao, Masa; Ikemoto, Kazumi; Yamasaki, Makoto; Nakashima, Ayako; Shimizu, Yuri; Otsubo, Yasufumi; Ando, Masanori; Jinno, Hideto; Tokunaga, Hiroshi

    2005-01-01

    Indoor air quality is currently a growing concern, mainly due to the incidence of sick building syndrome and building related illness. To better understand indoor air quality in Japan, both indoor and outdoor air samples were collected from 50 residences in Iwate, Yamanashi, Shiga, Hyogo, Kochi and Fukuoka Prefectures. More than 100 volatile organic compounds (VOCs) were analyzed by thermal desorption-gas chromatography/mass spectrometry method. The most abundant class of compounds present in the indoor air samples were identified (i.e. alkanes, alkylbenzenes and terpenes). For 30% of the indoor air samples, the sum of each VOC exceeded the current provisional guideline value for total VOC (TVOC, 400 microg/m3). The major component of these samples included linear and branched-chain alkanes (possibly derived from fossil fuels), 1,4-dichlorobenzene (a moth repellent), alpha-pinene (emission from woody building materials) and limonene (probably derived from aroma products). As an unexpected result, one residence was polluted with an extremely high concentration of 1,1,1,2-tetrafluoroethane (720 microg/m3), suggesting accidental leakage from a household appliance such as a refrigerator. The results presented in this paper are important in establishing the Japanese target compound list for TVOC analysis, as well as defining the current status of indoor air quality in Japan.

  10. Novel sample preparation technique with needle-type micro-extraction device for volatile organic compounds in indoor air samples.

    PubMed

    Ueta, Ikuo; Mizuguchi, Ayako; Fujimura, Koji; Kawakubo, Susumu; Saito, Yoshihiro

    2012-10-01

    A novel needle-type sample preparation device was developed for the effective preconcentration of volatile organic compounds (VOCs) in indoor air before gas chromatography-mass spectrometry (GC-MS) analysis. To develop a device for extracting a wide range of VOCs typically found in indoor air, several types of particulate sorbents were tested as the extraction medium in the needle-type extraction device. To determine the content of these VOCs, air samples were collected for 30min with the packed sorbent(s) in the extraction needle, and the extracted VOCs were thermally desorbed in a GC injection port by the direct insertion of the needle. A double-bed sorbent consisting of a needle packed with divinylbenzene and activated carbon particles exhibited excellent extraction and desorption performance and adequate extraction capacity for all the investigated VOCs. The results also clearly demonstrated that the proposed sample preparation method is a more rapid, simpler extraction/desorption technique than traditional sample preparation methods. PMID:22975183

  11. Sample normalization methods in quantitative metabolomics.

    PubMed

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts.

  12. Dynamic Method for Identifying Collected Sample Mass

    NASA Technical Reports Server (NTRS)

    Carson, John

    2008-01-01

    G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  13. Photographic sampling: a photographic sampling method for mites on plants.

    PubMed

    Sircom, J

    2000-01-01

    A photographic sampling method for mites on plants was evaluated using Tetranychus urticae and Phytoseiulus persimilis on pepper plants. It was found to be 92% accurate for T. urticae eggs and 98% accurate for P. persimilis eggs at densities up to 45 eggs per cm2 for T. urticae, and up to 3 eggs per cm2 for P. persimilis. The motiles of the two species were not confused, nor were they confused with exuviae or other matter.

  14. Determination of radiocarbon in stratospheric CO2, obtained through AirCore sampling.

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Chen, Huilin; Been, Henk A.; Kivi, Rigel; Meijer, Harro A. J.

    2016-04-01

    The concentration of Greenhouse Gases (GHG), with carbon dioxide as the most prominent example, has been and still is increasing, predominantly due to emissions from fossil fuel combustion. CO2 is also the most important component of the global carbon cycle. Among other tracers, radiocarbon (Carbon-14) is a unique and an important atmospheric tracer used in the understanding of the global carbon cycle. Radiocarbon is a naturally occurring isotope (radioactive, t 1/2 = 5730 ± 40 years) of carbon produced through the interaction of thermalized neutrons and nitrogen in the upper atmosphere. Generally, for performing atmospheric radiocarbon measurements in the higher atmosphere, large samples (few liters of air) were collected using aircrafts and balloons. However, collecting stratospheric samples on a regular basis for radiocarbon analysis is extremely expensive. Here we describe the determination of radiocarbon concentrations in stratospheric CO2, collected using AirCore sampling. AirCore is an innovative sampling technique for obtaining vertical atmospheric profiles and, in Europe, is done on a regular basis at Sodankylä, Finland for CO2, CH4 and CO. The stratospheric parts of two such AirCore profiles were used in this study as a proof-of-principle. CO2 from the stratospheric air samples were extracted and converted to elemental carbon, which were then measured at the Accelerator Mass Spectrometric (AMS) facility of the Centre for Isotope Research (CIO) at the University of Groningen. The stratospheric part of the AirCore profile was divided into six sections, each contained approximately 10 μg C. A detailed description of the extraction, graphitization, AMS analysis and the derivation of the stratospheric radiocarbon profile will be the main focus. Through our results, we will show that AirCore is a viable sampling method for performing high-precision radiocarbon measurements of stratospheric CO2 with reasonably good spatial resolution on a regular basis

  15. Feasibility Research on Alternative Approaches for Sampling and Extraction Methods in the TO-4A Method for Pesticides in Ambient Air with Analysis by GC/MS and LC/MS/MS

    EPA Science Inventory

    This compilation of methods is the result of a Regional Methods project between the U.S. Environmental Protection Agency Region 4 and the EPA’s Office of Research and Development. The research leading to these methods was conducted in response to an observed need to update an EPA...

  16. Thermodynamics of Air: Reinterpreting the Method of Clement and Desormes

    NASA Astrophysics Data System (ADS)

    Hornack, Frederick M.

    1996-10-01

    The well-known Clement-Desormes method for heat capacity ratio employs a large bottle of air, an oil manometer, and a rubber pressurizing bulb. The air sample at slightly elevated pressure undergoes a rapid adiabatic expansion followed by isochoric warming back to room temperature. The usual calculation of the ratio is sidestepped in favor of a new interpretation which recognizes that for air, the work done in the rapid expansion must equal the heat absorbed when the gas returns to room temperature. These quantitites and the accurately known differences between the PVT states permit a direct determination of the heat capacity Cv. Students are exposed to the concept of irreversible work, path independence of DeltaE, and experimentally use the equation DeltaE = Q + W. Since air is diatomic and closely obeys the ideal gas law, the heat capacities and various partial differential coefficients can be calculated and compared with experimental results.

  17. Radiocarbon analysis of stratospheric CO2 retrieved from AirCore sampling

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Chen, Huilin; Been, Henk A.; Kivi, Rigel; Meijer, Harro A. J.

    2016-10-01

    Radiocarbon (14C) is an important atmospheric tracer and one of the many used in the understanding of the global carbon budget, which includes the greenhouse gases CO2 and CH4. Measurement of radiocarbon in atmospheric CO2 generally requires the collection of large air samples (a few liters) from which CO2 is extracted and then the concentration of radiocarbon is determined using accelerator mass spectrometry (AMS). However, the regular collection of air samples from the stratosphere, for example using aircraft and balloons, is prohibitively expensive. Here we describe radiocarbon measurements in stratospheric CO2 collected by the AirCore sampling method. AirCore is an innovative atmospheric sampling system, which comprises a long tube descending from a high altitude with one end open and the other closed, and it has been demonstrated to be a reliable, cost-effective sampling system for high-altitude profile (up to ≈ 30 km) measurements of CH4 and CO2. In Europe, AirCore measurements have been being performed on a regular basis near Sodankylä (northern Finland) since September 2013. Here we describe the analysis of samples from two such AirCore flights made there in July 2014, for determining the radiocarbon concentration in stratospheric CO2. The two AirCore profiles were collected on consecutive days. The stratospheric part of the AirCore was divided into six sections, each containing ≈ 35 µg CO2 ( ≈ 9.6 µgC), and stored in a stratospheric air subsampler constructed from 1/4 in. coiled stainless steel tubing ( ≈ 3 m). A small-volume extraction system was constructed that enabled > 99.5 % CO2 extraction from the stratospheric air samples. Additionally, a new small-volume high-efficiency graphitization system was constructed for graphitization of these extracted CO2 samples, which were measured at the Groningen AMS facility. Since the stratospheric samples were very similar in mass, reference samples were also prepared in the same mass range for

  18. Systems and methods for sample analysis

    SciTech Connect

    Cooks, Robert Graham; Li, Guangtao; Li, Xin; Ouyang, Zheng

    2015-10-20

    The invention generally relates to systems and methods for sample analysis. In certain embodiments, the invention provides a system for analyzing a sample that includes a probe including a material connected to a high voltage source, a device for generating a heated gas, and a mass analyzer.

  19. Systems and methods for sample analysis

    DOEpatents

    Cooks, Robert Graham; Li, Guangtao; Li, Xin; Ouyang, Zheng

    2015-01-13

    The invention generally relates to systems and methods for sample analysis. In certain embodiments, the invention provides a system for analyzing a sample that includes a probe including a material connected to a high voltage source, a device for generating a heated gas, and a mass analyzer.

  20. Solubility testing of actinides on breathing-zone and area air samples

    SciTech Connect

    Metzger, R.L.; Jessop, B.H.; McDowell, B.L.

    1996-02-01

    A solubility testing method for several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALS{reg_sign}) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of U{sub 3}O{sub 8}. Profiles developed for U{sub 3}O{sub 8} samples show good agreement with in vitro and in vivo tests performed by other investigators on samples from the same uranium mills.

  1. Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2008-04-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

  2. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2009-01-23

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

  3. Bias in air sampling techniques used to measure inhalation exposure.

    PubMed

    Cohen, B S; Harley, N H; Lippmann, M

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and "mini hi-volume" samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. We conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  4. Bias in air sampling techniques used to measure inhalation exposure

    SciTech Connect

    Cohen, B.S.; Harley, N.H.; Lippmann, M.

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and mini hi-volume samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. The authors conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  5. Environmental Asbestos Assessment Manual: Superfund Method for the Determination of Asbestos in Ambient Air, Part 1: Method

    EPA Science Inventory

    This is a sampling and analysis method for the determination of asbestos in air. Samples are analyzed by transmission electron microscopy (TEM). Although a small subset of samples are to be prepared using a direct procedure, the majority of samples analyzed using this method wil...

  6. Method for sampling sub-micron particles

    DOEpatents

    Gay, Don D.; McMillan, William G.

    1985-01-01

    Apparatus and method steps for collecting sub-micron sized particles include a collection chamber and cryogenic cooling. The cooling is accomplished by coil tubing carrying nitrogen in liquid form, with the liquid nitrogen changing to the gas phase before exiting from the collection chamber in the tubing. Standard filters are used to filter out particles of diameter greater than or equal to 0.3 microns; however the present invention is used to trap particles of less than 0.3 micron in diameter. A blower draws air to said collection chamber through a filter which filters particles with diameters greater than or equal to 0.3 micron. The air is then cryogenically cooled so that moisture and sub-micron sized particles in the air condense into ice on the coil. The coil is then heated so that the ice melts, and the liquid is then drawn off and passed through a Buchner funnel where the liquid is passed through a Nuclepore membrane. A vacuum draws the liquid through the Nuclepore membrane, with the Nuclepore membrane trapping sub-micron sized particles therein. The Nuclepore membrane is then covered on its top and bottom surfaces with sheets of Mylar.RTM. and the assembly is then crushed into a pellet. This effectively traps the sub-micron sized particles for later analysis.

  7. Fluidics platform and method for sample preparation and analysis

    SciTech Connect

    Benner, W. Henry; Dzenitis, John M.; Bennet, William J.; Baker, Brian R.

    2014-08-19

    Herein provided are fluidics platform and method for sample preparation and analysis. The fluidics platform is capable of analyzing DNA from blood samples using amplification assays such as polymerase-chain-reaction assays and loop-mediated-isothermal-amplification assays. The fluidics platform can also be used for other types of assays and analyzes. In some embodiments, a sample in a sealed tube can be inserted directly. The following isolation, detection, and analyzes can be performed without a user's intervention. The disclosed platform may also comprises a sample preparation system with a magnetic actuator, a heater, and an air-drying mechanism, and fluid manipulation processes for extraction, washing, elution, assay assembly, assay detection, and cleaning after reactions and between samples.

  8. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, G.J.; Motes, B.G.; Bird, S.K.; Kotter, D.K.

    1996-03-26

    Apparatus for obtaining a whole gas sample, is composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method is described for obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant. 3 figs.

  9. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, Gary J.; Motes, Billy G.; Bird, Susan K.; Kotter, Dale K.

    1996-01-01

    Apparatus for obtaining a whole gas sample, composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method of obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant.

  10. Air-sampled Filter Analysis for Endotoxins and DNA Content.

    PubMed

    Lang-Yona, Naama; Mazar, Yinon; Pardo, Michal; Rudich, Yinon

    2016-01-01

    Outdoor aerosol research commonly uses particulate matter sampled on filters. This procedure enables various characterizations of the collected particles to be performed in parallel. The purpose of the method presented here is to obtain a highly accurate and reliable analysis of the endotoxin and DNA content of bio-aerosols extracted from filters. The extraction of high molecular weight organic molecules, such as lipopolysaccharides, from sampled filters involves shaking the sample in a pyrogen-free water-based medium. The subsequent analysis is based on an enzymatic reaction that can be detected using a turbidimetric measurement. As a result of the high organic content on the sampled filters, the extraction of DNA from the samples is performed using a commercial DNA extraction kit that was originally designed for soils and modified to improve the DNA yield. The detection and quantification of specific microbial species using quantitative polymerase chain reaction (q-PCR) analysis are described and compared with other available methods. PMID:27023725

  11. An Autosampler and Field Sample Carrier for Maximizing Throughput Using an Open-Air, Surface Sampling Ion Source for MS

    EPA Science Inventory

    A recently developed, commercially available, open-air, surface sampling ion source for mass spectrometers provides individual analyses in several seconds. To realize its full throughput potential, an autosampler and field sample carrier were designed and built. The autosampler ...

  12. An approach to area sampling and analysis for total isocyanates in workplace air.

    PubMed

    Key-Schwartz, R J; Tucker, S P

    1999-01-01

    An approach to sampling and analysis for total isocyanates (monomer plus any associated oligomers of a given isocyanate) in workplace air has been developed and evaluated. Based on a method developed by the Occupational Health Laboratory, Ontario Ministry of Labour, Ontario, Canada, isocyanates present in air are derivatized with a fluorescent reagent, tryptamine, in an impinger and subsequently analyzed via high-performance liquid chromatography (HPLC) with fluorescence detection. Excitation and emission wavelengths are set at 275 and 320 nm, respectively. A modification to the Ontario method was made in the replacement of the recommended impinger solvents (acetonitrile and 2,2,4-trimethylpentane) with dimethyl sulfoxide (DMSO). DMSO has the advantages of being compatible with reversedphase HPLC and not evaporating during sampling, as do the more volatile solvents used in the Ontario method. DMSO also may dissolve aerosol particles more efficiently during sampling than relatively nonpolar solvents. Several formulations containing diisocyanate prepolymers have been tested with this method in the laboratory. This method has been issued as National Institute for Occupational Safety and Health (NIOSH) Method 5522 in the first supplement to the fourth edition of the NIOSH Manual of Analytical Methods. This method is recommended for area sampling only due to possible hazards from contact with DMSO solutions containing isocyanate derivatives. The limits of detection are 0.1 microgram/sample for 2,4-toluene diisocyanate, 0.2 microgram/sample for 2,6-toluene diisocyanate, 0.3 microgram/sample for methylene bisphenyl diisocyanate, and 0.2 microgram/sample for 1,6-hexamethylene diisocyanate.

  13. Diffusive sampling and measurement of microbial volatile organic compounds in indoor air.

    PubMed

    Araki, A; Eitaki, Y; Kawai, T; Kanazawa, A; Takeda, M; Kishi, R

    2009-10-01

    Microbial volatile organic compounds (MVOC), chemicals emitted from various microorganisms, in indoor air have been of concern in recent years. For large field studies, diffusive samplers are widely used to measure indoor environments. Since the sampling rate of a sampler is a fundamental parameter to calculate concentration, the sampling rates of eight MVOC with diffusive samplers were determined experimentally using a newly developed water-bubbling method: air was supplied to the MVOC-solutions and the vapor collected in an exposure bag, where diffusive and active samplers were placed in parallel for comparison. Correlations between the diffusive and active samplings gave good linear regressions. The sampling rates were 30-35 ml/min and the detection limits were 0.044-0.178 microg/m(3), as determined by GC/MS analysis. Application of the sampling rates in indoor air was validated by parallel sampling of the diffusive and active sampling method. 5% Propan-2-ol/CS(2) was the best solvent to desorb the compounds from absorbents. The procedure was applied to a field study in 41 dwellings. The most frequently detected compounds were hexan-2-one and heptan-2-one, with 97.5% detection rates and geometric mean values of 0.470 and 0.302 microg/m(3), respectively. This study shows that diffusive samplers are applicable to measure indoor MVOC levels. Practical Implications At present, there are still limited reports on indoor Microbial Volatile Organic Compounds (MVOC) levels in general dwellings and occupants' health. Compared with active sampling methods, air sampling using a diffusive sampler is particularly advantageous for use in large field studies due to its smallness, light-size, easy-handling, and cost-effectiveness. In this study, sampling rates of selected MVOC of the diffusive sampler were determined using the water-bubbling method: generating gases by water-bubbling and exposing the diffusive and active samplers at the same time. The obtained sampling rates

  14. Determination of methyl bromide in air samples by headspace gas chromatography

    SciTech Connect

    Woodrow, J.E.; McChesney, M.M.; Seiber, J.N.

    1988-03-01

    Methyl bromide is extensively used in agriculture (4 x 10/sup 6/ kg for 1985 in California alone as a fumigant to control nematodes, weeds, and fungi in soil and insect pests in harvested grains and nuts. Given its low boiling point (3.8/sup 0/C) and high vapor pressure (approx. 1400 Torr at 20/sup 0/C), methyl bromide will readily diffuse if not rigorously contained. Methods for determining methyl bromide and other halocarbons in air vary widely. A common practice is to trap the material from air on an adsorbent, such as polymeric resins, followed by thermal desorption either directly into the analytical instrumentation or after intermediary cryofocusing. While in some cases analytical detection limits were reasonable (parts per million range), many of the published methods were labor intensive and required special handling techniques that precluded high sample throughput. They describe here a method for the sampling and analysis of airborne methyl bromide that was designed to handle large numbers of samples through automating some critical steps of the analysis. The result was a method that allowed around-the-clock operation with a minimum of operator attention. Furthermore, the method was not specific to methyl bromide and could be used to determine other halocarbons in air.

  15. Air flow assisted ionization for remote sampling of ambient mass spectrometry and its application.

    PubMed

    He, Jiuming; Tang, Fei; Luo, Zhigang; Chen, Yi; Xu, Jing; Zhang, Ruiping; Wang, Xiaohao; Abliz, Zeper

    2011-04-15

    Ambient ionization methods are an important research area in mass spectrometry (MS) analysis. Under ambient conditions, the gas flow and atmospheric pressure significantly affect the transfer and focusing of ions. The design and implementation of air flow assisted ionization (AFAI) as a novel and effective, remote sampling method for ambient mass spectrometry are described herein. AFAI benefits from a high extracting air flow rate. A systematic investigation of the extracting air flow in the AFAI system has been carried out, and it has been demonstrated not only that it plays a role in the effective capture and remote transport of charged droplets, but also that it promotes desolvation and ion formation, and even prevents ion fragmentation during the ionization process. Moreover, the sensitivity of remote sampling ambient MS analysis was improved significantly by the AFAI method. Highly polar and nonpolar molecules, including dyes, pharmaceutical samples, explosives, drugs of abuse, protein and volatile compounds, have been successfully analyzed using AFAI-MS. The successful application of the technique to residue detection on fingers, large object analysis and remote monitoring in real time indicates its potential for the analysis of a variety of samples, especially large objects. The ability to couple this technique with most commercially available MS instruments with an API interface further enhances its broad applicability.

  16. Detection of virulent Rhodococcus equi in exhaled air samples from naturally infected foals.

    PubMed

    Muscatello, G; Gilkerson, J R; Browning, G F

    2009-03-01

    Virulent Rhodococcus equi causes pyogranulomatous bronchopneumonia in foals. The route of infection of foals has been considered to be inhalation of aerosolized bacteria from soil that is contaminated with equine feces. Thus, disease caused by R. equi has been regarded as an opportunistic infection of environmental origin and not a contagious disease. In this study, we report the exhalation of virulent R. equi from the respiratory tract of naturally infected foals. A handheld air-monitoring system was used to recover virulent R. equi from the exhaled breath of foals, and the concentration of virulent R. equi organisms in exhaled air was compared to the concentration in environmental air samples taken from the holding pens and lane areas on farms. R. equi strains carrying the vapA gene of the virulence plasmid were detected by using colony blotting and DNA hybridization techniques in cultures of exhaled air from 67% (37/55) of foals tested. The concentration of virulent R. equi organisms in exhaled air from foals was significantly higher than that in environmental air (P<0.001). There were no significant differences in the median concentrations of virulent R. equi bacteria exhaled by clinically healthy or diseased foals. The high concentrations of virulent R. equi bacteria in exhaled air suggested that aerosol transmission between foals is possible and may have a significant impact on the prevalence of R. equi pneumonia on farms. The air sampling technique described is potentially useful as a noninvasive method for the detection and quantification of virulent R. equi in the respiratory tract of foals.

  17. Continuous air monitor correlation to fixed air sample data at Los Alamos National Laboratory

    SciTech Connect

    Whicker, J.J.

    1993-05-01

    Continuous air monitoring instruments (CAMS) deployed in laboratories in the TA-55 plutonium facility at Los Alamos National Laboratory (LANL) alarmed less than 33 percent of the time when fixed air sample measurements in the same laboratory showed integrated concentrations exceeding 500 DAC-hrs. The purpose of this study was to explore effects of non-instrument variables on alarm sensitivities for properly working CAMS. Non-instrument variables include air flow patterns, particle size of released material, and the energy of the release. Dilution Factors (DFs) for 21 airborne releases in various rooms and of different magnitudes were calculated and compared. The median DF for releases where the CAM alarmed was 13.1 while the median DF for releases where the CAM did not alarm was 179. Particle sizes ranged considerably with many particles larger than 10 {mu}m. The cause of the release was found to be important in predicting if a CAM would alarm with releases from bagouts resulting in the greatest percentage of CAM alarms. The results of this study suggest that a two-component strategy for CAM placement at LANL be utilized. The first component would require CAMs at exhaust points in the rooms to provide for reliable detection for random release locations. The second component would require placing CAMs at locations where releases have historically been seen. Finally, improvements in CAM instrumentation is needed.

  18. Mixed species radioiodine air sampling readout and dose assessment system

    DOEpatents

    Distenfeld, Carl H.; Klemish, Jr., Joseph R.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector.

  19. Evaluation of passive air sampler calibrations: Selection of sampling rates and implications for the measurement of persistent organic pollutants in air

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Robson, Matthew; Helm, Paul A.; Diamond, Miriam L.

    2011-04-01

    Polyurethane foam (PUF) passive air samplers (PAS) are a common and highly useful method of sampling persistent organic pollutants (POP) concentrations in air. PAS calibration is necessary to obtain reasonable and comparable semi-quantitative measures of air concentrations. Various methods are found in the literature concerning PAS calibration. 35 studies on PAS use and calibration are examined here, in conjunction with a study involving 10 PAS deployed concurrently in outdoor air with a low-volume air sampler in order to measure the sampling rates of PUF-PAS for polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), polycyclic musks (PCMs), and polycyclic aromatic hydrocarbons (PAHs). Based on this analysis it is recommended that (1) PAS should be assumed to represent bulk rather than gas-phase compound concentrations due to the sampling of particle-bound compounds, (2) calibration of PAS sampling rates is more accurately achieved using an active low-volume air sampler rather than depuration compounds since the former measures gas- and particle-phase compounds and does so continuously over the deployment period of the PAS, and (3) homolog-specific sampling rates based on KOA groupings be used in preference to compound/congener-specific or single sampling rates.

  20. Bayesian individualization via sampling-based methods.

    PubMed

    Wakefield, J

    1996-02-01

    We consider the situation where we wish to adjust the dosage regimen of a patient based on (in general) sparse concentration measurements taken on-line. A Bayesian decision theory approach is taken which requires the specification of an appropriate prior distribution and loss function. A simple method for obtaining samples from the posterior distribution of the pharmacokinetic parameters of the patient is described. In general, these samples are used to obtain a Monte Carlo estimate of the expected loss which is then minimized with respect to the dosage regimen. Some special cases which yield analytic solutions are described. When the prior distribution is based on a population analysis then a method of accounting for the uncertainty in the population parameters is described. Two simulation studies showing how the methods work in practice are presented. PMID:8827585

  1. Cellulomonas aerilata sp. nov., isolated from an air sample.

    PubMed

    Lee, Chang-Muk; Weon, Hang-Yeon; Hong, Seung-Beom; Jeon, Young-Ah; Schumann, Peter; Kroppenstedt, Reiner M; Kwon, Soon-Wo; Stackebrandt, Erko

    2008-12-01

    A Gram-positive, aerobic, motile, coccoid or short rod-shaped bacterium, 5420S-23(T), was isolated from an air sample collected in the Republic of Korea. According to phylogenetic analysis based on 16S rRNA gene sequences, strain 5420S-23(T) revealed 97.5, 97.3, 97.3 and 97.2 % similarity, respectively, to Cellulomonas biazotea DSM 20112(T), Cellulomonas cellasea DSM 20118(T), Cellulomonas fimi DSM 20113(T) and Cellulomonas chitinilytica X.bu-b(T). The peptidoglycan type of strain 5420S-23(T) was A4beta, containing l-ornithine-d-glutamic acid. The cell-wall sugars were galactose, glucose and xylose. The major fatty acids were anteiso-C(15 : 0) (49.7 %) and C(16 : 0) (20.0 %). The major menaquinone was MK-9(H(4)) and major polar lipids were diphosphatidylglycerol and phosphatidylglycerol. The DNA G+C content was 74 mol%. The results of DNA-DNA hybridization with strains of closely related Cellulomonas species, in combination with chemotaxonomic and physiological data, demonstrated that isolate 5420S-23(T) represents a novel Cellulomonas species, for which the name Cellulomonas aerilata sp. nov. is proposed, with strain 5420S-23(T) (=KACC 20692(T) =DSM 18649(T)) as the type strain.

  2. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  3. Actinide recovery method -- Large soil samples

    SciTech Connect

    Maxwell , S.L. III

    2000-04-25

    There is a need to measure actinides in environmental samples with lower and lower detection limits, requiring larger sample sizes. This analysis is adversely affected by sample-matrix interferences, which make analyzing soil samples above five-grams very difficult. A new Actinide-Recovery Method has been developed by the Savannah River Site Central Laboratory to preconcentrate actinides from large-soil samples. Diphonix Resin (Eichrom Industries), a 1994 R and D 100 winner, is used to preconcentrate the actinides from large soil samples, which are bound powerfully to the resin's diphosphonic acid groups. A rapid microwave-digestion technique is used to remove the actinides from the Diphonix Resin, which effectively eliminates interfering matrix components from the soil matrix. The microwave-digestion technique is more effective and less tedious than catalyzed hydrogen peroxide digestions of the resin or digestion of diphosphonic stripping agents such as HEDPA. After resin digestion, the actinides are recovered in a small volume of nitric acid which can be loaded onto small extraction chromatography columns, such as TEVA Resin, U-TEVA Resin or TRU Resin (Eichrom Industries). Small, selective extraction columns do not generate large volumes of liquid waste and provide consistent tracer recoveries after soil matrix elimination.

  4. Method and apparatus for sampling low-yield wells

    DOEpatents

    Last, George V.; Lanigan, David C.

    2003-04-15

    An apparatus and method for collecting a sample from a low-yield well or perched aquifer includes a pump and a controller responsive to water level sensors for filling a sample reservoir. The controller activates the pump to fill the reservoir when the water level in the well reaches a high level as indicated by the sensor. The controller deactivates the pump when the water level reaches a lower level as indicated by the sensors. The pump continuously activates and deactivates the pump until the sample reservoir is filled with a desired volume, as indicated by a reservoir sensor. At the beginning of each activation cycle, the controller optionally can select to purge an initial quantity of water prior to filling the sample reservoir. The reservoir can be substantially devoid of air and the pump is a low volumetric flow rate pump. Both the pump and the reservoir can be located either inside or outside the well.

  5. A comparison of two ozone sampling methods

    SciTech Connect

    Downey, E.B.; Buchan, R.M.; Blehm, K.D.; Gunter, B.J.

    1983-05-01

    A study was conducted to compare the alkaline potassium iodide (AKI) impinger method versus a direct-reading chemiluminescent monitor for determining ozone concentrations. Comparisons were made in both a controlled laboratory situation and in the field during MIG welding. Laboratoy results indicated that the accuracy of the AKI procedure is affected by sample size. In the field, AKI impinger samples seemed to give very low estimations of the true ozone concentration. The direct-reading chemiluminescent monitor performed excellently in both the laboratory and field, and exhibited its merit as an industrial hygiene field instrument.

  6. Air sampling filtration media: Collection efficiency for respirable size-selective sampling

    PubMed Central

    Soo, Jhy-Charm; Monaghan, Keenan; Lee, Taekhee; Kashon, Mike; Harper, Martin

    2016-01-01

    The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min−1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes. PMID:26834310

  7. Analysis of a workplace air particulate sample by synchronous luminescence and room-temperature phosphorescence

    SciTech Connect

    Vo-Dinh, T.; Gammage, R.B.; Martinez, P.R.

    1981-02-01

    An analysis of a XAD-2 resin extract of a particulate air sample collected at an industrial environment was conducted by use of two simple spectroscopic methods performed at ambient temperature, the synchronous luminescence and room-temperature phosphorescence techniques. Results of the analysis of 13 polynuclear aromatic compounds including anthracene, benzo(a)pyrene, benzo(e)pyrene, 2,3-benzofluorene, chrysene, 1,2,5,6-dibenzanthracene, dibenzthiophene, fluoranthene, fluorene, phenanthrene, perylene, pyrene, and tetracene were reported.

  8. Actinide Recovery Method for Large Soil Samples

    SciTech Connect

    Maxwell, S.L. III; Nichols, S.

    1998-11-01

    A new Actinide Recovery Method has been developed by the Savannah River Site Central Laboratory to preconcentrate actinides in very large soil samples. Diphonix Resin(r) is used eliminate soil matrix interferences and preconcentrate actinides after soil leaching or soil fusion. A rapid microwave digestion technique is used to remove the actinides from the Diphonix Resin(r). After the resin digestion, the actinides are recovered in a small volume of nitric acid which can be easily loaded onto small extraction-chromatography columns, such as TEVA Resin(r), U-TEVA Resin(r) or TRU Resin(r) (Eichrom Industries). This method enables the application of small, selective extraction-columns to recover actinides from very large soil samples with high selectivity, consistent tracer recoveries and minimal liquid waste.

  9. Method, system and apparatus for monitoring and adjusting the quality of indoor air

    DOEpatents

    Hartenstein, Steven D.; Tremblay, Paul L.; Fryer, Michael O.; Hohorst, Frederick A.

    2004-03-23

    A system, method and apparatus is provided for monitoring and adjusting the quality of indoor air. A sensor array senses an air sample from the indoor air and analyzes the air sample to obtain signatures representative of contaminants in the air sample. When the level or type of contaminant poses a threat or hazard to the occupants, the present invention takes corrective actions which may include introducing additional fresh air. The corrective actions taken are intended to promote overall health of personnel, prevent personnel from being overexposed to hazardous contaminants and minimize the cost of operating the HVAC system. The identification of the contaminants is performed by comparing the signatures provided by the sensor array with a database of known signatures. Upon identification, the system takes corrective actions based on the level of contaminant present. The present invention is capable of learning the identity of previously unknown contaminants, which increases its ability to identify contaminants in the future. Indoor air quality is assured by monitoring the contaminants not only in the indoor air, but also in the outdoor air and the air which is to be recirculated. The present invention is easily adaptable to new and existing HVAC systems. In sum, the present invention is able to monitor and adjust the quality of indoor air in real time by sensing the level and type of contaminants present in indoor air, outdoor and recirculated air, providing an intelligent decision about the quality of the air, and minimizing the cost of operating an HVAC system.

  10. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi, Shanavaz; Langlois, Richard G.; Venkateswaran, Kodumudi S.

    2006-08-01

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM, on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA, on the 5' end.

  11. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi,Shanavaz; Langlois, Richard G.; Venkateswaran, Kodumudi S.

    2011-07-05

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM.TM. on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA.TM., on the 5' end.

  12. Breakthrough of 1,3-dichloropropene and chloropicrin from 600 mg XAD-4 air sampling tubes

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Accurately measuring air concentrations of agricultural fumigants is important for the regulation of air quality. Understanding the conditions under which sorbent tubes can effectively retain such fumigants during sampling is critical in mitigating chemical breakthrough from the tubes and facilitati...

  13. Spirosoma aerophilum sp. nov., isolated from an air sample.

    PubMed

    Kim, Soo-Jin; Ahn, Jae-Hyung; Weon, Hang-Yeon; Hong, Seung-Beom; Seok, Soon-Ja; Kim, Jeong-Seon; Kwon, Soon-Wo

    2016-06-01

    A rod-shaped, yellow, Gram-stain-negative, non-flagellated, aerobic bacterium, designated 5516J-17T, was isolated from an air sample collected from Jeju Island, Republic of Korea. It grew in the temperature range of 10-37 °C (optimum 28-30 °C), pH 6.0-11.0 (optimum, pH 7.0) and 0-1 % NaCl (w/v). Phylogenetic trees generated using 16S rRNA gene sequences revealed that strain 5516J-17T belongs to the genus Spirosoma, showing 96.9 % sequence similarity to the most closely related species, Spirosoma linguale DSM 74T. The cellular fatty acids comprised large amounts (>10 % of total fatty acids) of summed feature 3 (C16:1ω7c and/or C16:1ω6c) and C16:1ω5c, and moderate amounts (5-10 % of total fatty acids) of iso-C17:0 3-OH, iso-C15:0 and C16:0. The DNA G+C content was 55.7 mol % and MK-7 was the predominant isoprenoid quinone. Polar lipids were phosphatidylethanolamine, two unknown aminophospholipids, one unknown aminolipid and one unknown lipid. On the basis of this phenotypic and polyphasic taxonomy study, it is suggested that strain 5516J-17T represents a novel species within the genus Spirosoma, with the proposed name Spirosoma aerophilum. The type strain is 5516J-17T (= KACC 17323T = DSM 28388T = JCM 19950T). PMID:27031168

  14. Terrabacter aeriphilus sp. nov., isolated from an air sample.

    PubMed

    Weon, Hang-Yeon; Son, Jung-A; Yoo, Seung-Hee; Kim, Byung-Yong; Kwon, Soon-Wo; Schumann, Peter; Kroppenstedt, Reiner; Stackebrandt, Erko

    2010-05-01

    A novel actinomycete, designated strain 5414T-18(T), was isolated from an air sample collected from the Taean region, Korea. The strain contained oxidase and grew in the presence of 7 % NaCl. A neighbour-joining tree constructed on the basis of the 16S rRNA gene sequence showed that strain 5414T-18(T) is a member of the genus Terrabacter, sharing 97.8-98.3 % 16S rRNA gene sequence similarities to type strains of species of the genus Terrabacter (98.3 % sequence similarity with Terrabacter lapilli LR-26(T)). It contained peptidoglycan containing ll-diaminopimelic acid of A3gamma type, with three glycine residues as the interpeptide bridge. Whole-cell sugars were glucose, mannose and ribose. Mycolic acids were absent. The predominant menaquinone was MK-8(H(4)). The major fatty acids (>7 % of total fatty acids) were iso-C(15 : 0), iso-C(16 : 0), C(17 : 1)omega8c and iso-C(14 : 0). The major polar lipids were phosphatidylethanolamine, diphosphatidylglycerol, phosphatidylinositol and an unidentified phosphoglycolipid. The DNA G+C content of the type strain was 73 mol%. Strain 5414T-18(T) exhibited DNA-DNA relatedness levels of 44, 43, 39, 34 and 34 % to the type strains of Terrabacter lapilli, Terrabacter aerolatus, Terrabacter terrae, Terrabacter tumescens and Terracoccus luteus, respectively. These findings suggest that strain 5414T-18(T) represents a novel species within the genus Terrabacter. The name Terrabacter aeriphilus sp. nov. is proposed for this novel species, with the type strain 5414T-18(T) (=KACC 20693(T)=DSM 18563(T)).

  15. [Analysis of polycyclic aromatic hydrocarbons in air samples by gas chromatography-triple quadrupole mass spectrometry].

    PubMed

    Zhao, Bo; Li, Yuqing; Zhang, Sukun; Han, Jinglei; Xu, Zhencheng; Fang, Jiande

    2014-09-01

    A method of gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-MS/MS) has been optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in air samples. In the analysis step, isotope dilution was introduced to the quantification of PAHs. The GC-MS/MS method was applied to the analysis of the real air samples around a big petrochemical power plant in South China. The results were compared with those obtained by gas chromatography coupled to mass spectrometry (GC-MS). The results showed that better selectivity and sensitivity were obtained by GC-MS/MS. It was found that the external standard of deuterated-PAHs and internal standard of hexamethyl benzene were disturbed seriously with GC-MS, and the problems were both solved effectively by GC-MS/MS. Therefore more accurate quantification results of PAHs were obtained with GC-MS/MS. For the analysis of real samples, the RSDs of relative response factors ranged from 2.60% to 15.6% in standard curves; the recoveries of deuterated-PAHs ranged from 55.2% to 82.3%; the recoveries of spiked samples ranged from 98.9% to 111%; the RSDs of parallel specimens ranged from 6.50% to 18.4%; the concentrations of field blank samples ranged from not detected to 44.3 pg/m3; and the concentrations of library blank samples ranged from not detected to 36.5 pg/m3. The study indicated that the application of GC-MS/MS on the analysis of PAHs in air samples was recommended. PMID:25752088

  16. Passive sampling of glycol ethers and their acetates in indoor air.

    PubMed

    Plaisance, H; Desmettres, P; Leonardis, T; Pennequin-Cardinal, A; Locoge, N; Galloo, J-C

    2008-04-01

    This study examined the performances of a thermal desorbable radial diffusive sampler for the weekly measurement of eight glycol ethers in indoor air and described the results of an application of this method carried out as part of HABIT'AIR Nord - Pas de Calais program for the air monitoring of these compounds in sixty homes located in northern France. The target compounds were the four glycol ethers banned from sale to the public in France since the 1990s (i.e. 2-methoxy ethanol, 2-ethoxy ethanol and their acetates) and four other glycol ethers derivatives of which the use have increased considerably (i.e. 1-methoxy-2-propanol, 2-butoxy ethanol and their acetates).A test program was carried out with the aim of validating the passive sampling method. It allowed the estimation of all the parameters of a method for each compound (calibration, analytical precision, desorption efficiency, sampling rate in standard conditions, detection limit and stability of sample before and after exposure), the examination of the influence of environmental factors on the sampling rate by some exposure chamber experiments and the assessment of the uncertainty of the measurements. The results of this evaluation demonstrated that the method has turned out to be suitable for six out of eight glycol ethers tested. The effect of the environmental factors on the sampling rates was the main source of measurement uncertainty. The measurements done in sixty homes revealed a relative abundance of 1-methoxy-2-propanol that was found in more than two thirds of homes at concentration levels of 4.5 microg m(-3) on average (a maximum value of 28 microg m(-3)). 1-methoxy-2-propanol acetate and 2-butoxy ethanol were also detected, but less frequently (in 19% of homes) and with the concentrations below 12 microg m(-3). The highest levels of these glycol ethers appear to be in relation to the emissions occurring at the time of cleaning tasks.

  17. Microbial air-sampling equipment, part 1: meeting United States pharmacopeia chapter 797 standards.

    PubMed

    Kastango, Eric S

    2008-01-01

    The most recent changes to Chapter 797 of the United States Pharmcopeia-National Formulary initiated an intense controversy about the frequency of cleanroom air sampling that is required to prevent the contamination of sterile preparations. For compounders who must purchase an air sampler to use in the cleanroom, choices abound. Included in this article are a review of United States Pharmacopeia-National Formulary requirements that pertain to air sampling, a discussion of how recent revision to Chapter 797 affect air sampling and patient safety, and, for easy reference, a table that features specifications for various models of microbial air samplers.

  18. Combustor air flow control method for fuel cell apparatus

    DOEpatents

    Clingerman, Bruce J.; Mowery, Kenneth D.; Ripley, Eugene V.

    2001-01-01

    A method for controlling the heat output of a combustor in a fuel cell apparatus to a fuel processor where the combustor has dual air inlet streams including atmospheric air and fuel cell cathode effluent containing oxygen depleted air. In all operating modes, an enthalpy balance is provided by regulating the quantity of the air flow stream to the combustor to support fuel cell processor heat requirements. A control provides a quick fast forward change in an air valve orifice cross section in response to a calculated predetermined air flow, the molar constituents of the air stream to the combustor, the pressure drop across the air valve, and a look up table of the orifice cross sectional area and valve steps. A feedback loop fine tunes any error between the measured air flow to the combustor and the predetermined air flow.

  19. Field evaluation of sampling and analysis for organic pollutants in indoor air. Project summary

    SciTech Connect

    Chuang, J.C.; Mack, G.A.; Stockrahm, J.W.; Hannan, S.W.; Bridges, C.

    1988-09-01

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in residential air.

  20. Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns.

    PubMed Central

    Whyatt, Robin M; Barr, Dana B; Camann, David E; Kinney, Patrick L; Barr, John R; Andrews, Howard F; Hoepner, Lori A; Garfinkel, Robin; Hazi, Yair; Reyes, Andria; Ramirez, Judyth; Cosme, Yesenia; Perera, Frederica P

    2003-01-01

    We have measured 29 pesticides in plasma samples collected at birth between 1998 and 2001 from 230 mother and newborn pairs enrolled in the Columbia Center for Children's Environmental Health prospective cohort study. Our prior research has shown widespread pesticide use during pregnancy among this urban minority cohort from New York City. We also measured eight pesticides in 48-hr personal air samples collected from the mothers during pregnancy. The following seven pesticides were detected in 48-83% of plasma samples (range, 1-270 pg/g): the organophosphates chlorpyrifos and diazinon, the carbamates bendiocarb and 2-isopropoxyphenol (metabolite of propoxur), and the fungicides dicloran, phthalimide (metabolite of folpet and captan), and tetrahydrophthalimide (metabolite of captan and captafol). Maternal and cord plasma levels were similar and, except for phthalimide, were highly correlated (p < 0.001). Chlorpyrifos, diazinon, and propoxur were detected in 100% of personal air samples (range, 0.7-6,010 ng/m(3)). Diazinon and propoxur levels were significantly higher in the personal air of women reporting use of an exterminator, can sprays, and/or pest bombs during pregnancy compared with women reporting no pesticide use or use of lower toxicity methods only. A significant correlation was seen between personal air level of chlorpyrifos, diazinon, and propoxur and levels of these insecticides or their metabolites in plasma samples (maternal and/or cord, p < 0.05). The fungicide ortho-phenylphenol was also detected in 100% of air samples but was not measured in plasma. The remaining 22 pesticides were detected in 0-45% of air or plasma samples. Chlorpyrifos, diazinon, propoxur, and bendiocarb levels in air and/or plasma decreased significantly between 1998 and 2001. Findings indicate that pesticide exposures are frequent but decreasing and that the pesticides are readily transferred to the developing fetus during pregnancy. PMID:12727605

  1. Air sampling of flame retardants based on the use of mixed-bed sorption tubes--a validation study.

    PubMed

    Lazarov, Borislav; Swinnen, Rudi; Spruyt, Maarten; Maes, Frederick; Van Campenhout, Karen; Goelen, Eddy; Covaci, Adrian; Stranger, Marianne

    2015-11-01

    An analytical methodology using automatic thermal desorption and gas chromatography mass spectrometry analysis was optimized and validated for simultaneous determination of a set of components from three different flame retardant chemical classes: polybrominated diphenyl ethers (PBDEs) (PBDE-28, PBDE-47, PBDE-66, PBDE-85, PBDE-99, PBDE-100), organophosphate flame retardants (PFRs) (tributyl phosphate, tripropyl phosphate, tris(2-chloroethyl)phosphate-, tris(1,3-dichloro-2-propyl) phosphate, tris(2-ethylhexyl) phosphate, triphenyl phosphate, tris(2-chloro-1-methylethyl) phosphate and tricresylphosphate), and "novel" brominated flame retardants (NBFRs) (pentabromotoluene, 2,3,4,5,6-pentabromoethylbenzene, (2,3-dibromopropyl) (2,4,6-tribromophenyl) ether, hexabromobenzene, and 2-ethylhexyl 2,3,4,5-tetrabromobenzoate) in air. The methodology is based on low volume active air sampling of gaseous and particulate air fractions on mixed-bed (polydimethylsiloxane (PDMS)/Tenax TA) sorption tubes. The optimized method provides recoveries >88%; a limit of detection in the range of 6-25 pg m(-3) for PBDEs, 6-171 pg m(-3) for PFRs, and 7-41 pg m(-3) for NBFRs; a linearity greater than 0.996; and a repeatability of less than 10% for all studied compounds. The optimized method was compared with a standard method using active air sampling on XAD-2 sorbent material, followed by liquid extraction. On the one hand, the PDMS/Tenax TA method shows comparable results at longer sampling time conditions (e.g., indoor air sampling, personal air sampling). On the other hand, at shorter sampling time conditions (e.g., sampling from emission test chambers), the optimized method detects up to three times higher concentrations and identifies more flame retardant compounds compared to the standard method based on XAD-2 loading.

  2. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING AIR SAMPLES FOR ANALYSIS OF POLAR PERSISTENT ORGANIC POLLUTANTS (SOP-5.13)

    EPA Science Inventory

    The method for extracting and preparing indoor and outdoor air samples for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the preparation of samples that are to be analyzed by gas chromatography/mass spectrometry.

  3. Rapid on-site air sampling with a needle extraction device for evaluating the indoor air environment in school facilities.

    PubMed

    Inoue, Mitsuru; Mizuguchi, Ayako; Ueta, Ikuo; Takahashi, Kazuya; Saito, Yoshihiro

    2013-01-01

    A rapid on-site air sampling technique was developed with a miniaturized needle-type sample preparation device for a systematic evaluation of the indoor air environments in school facilities. With the in-needle extraction device packed with a polymer particle of divinylbenzene and activated carbon particles, various types of volatile organic compounds (VOCs) were successfully extracted. For evaluating the indoor air qualities in school facilities, air samples in renovated rooms using organic solvent as a thinner of the paint were analyzed along with measurements of several VOCs in indoor air samples taken in newly built primary schools mainly using low-VOCs materials. After periodical renovation/maintenance, the time-variation profile of typical VOCs found in the school facilities has also been monitored. From the results, it could be observed that the VOCs in most of the rooms in these primary schools were at a quite low level; however, a relatively higher concentration of VOCs was found in some specially designed rooms, such as music rooms. In addition, some non-regulated compounds, including benzyl alcohol and branched alkanes, were detected in these primary schools. The results showed a good applicability of the needle device to indoor air analysis in schools, suggesting a wide range of future employment of the needle device, especially for indoor air analysis in other types of facilities and rooms including hospitals and hotels. PMID:23665624

  4. Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air.

    PubMed

    Attari, Seyed Ghavameddin; Bahrami, Abdolrahman; Shahna, Farshid Ghorbani; Heidari, Mahmoud

    2014-01-01

    A green, environmental friendly and sensitive method for determination of volatile organohalogen compounds was described in this paper. The method is based on a homemade sol-gel single-walled carbon nanotube/silica composite coated solid-phase microextraction to develop for sampling and analysis of Carbon tetrachloride, Benzotrichloride, Chloromethyl methyl ether and Trichloroethylene in air. Application of this method was investigated under different laboratory conditions. Predetermined concentrations of each analytes were prepared in a home-made standard chamber and the influences of experimental parameters such as temperature, humidity, extraction time, storage time, desorption temperature, desorption time and the sorbent performance were investigated. Under optimal conditions, the use of single-walled carbon nanotube/silica composite fiber showed good performance, high sensitive and fast sampling of volatile organohalogen compounds from air. For linearity test the regression correlation coefficient was more than 98% for analyte of interest and linear dynamic range for the proposed fiber and the applied Gas Chromatography-Flame Ionization Detector technique was from 1 to 100 ngmL(-1). Method detection limits ranged between 0.09 to 0.2 ngmL(-1) and method quantification limits were between 0.25 and 0.7 ngmL(-1). Single-walled carbon nanotube/silica composite fiber was highly reproducible, relative standard deviations were between 4.3 to 11.7 percent. PMID:25279223

  5. System and Method for Isolation of Samples

    NASA Technical Reports Server (NTRS)

    Zhang, Ye (Inventor); Wu, Honglu (Inventor)

    2014-01-01

    Systems and methods for isolating samples are provided. The system comprises a first membrane and a second membrane disposed within an enclosure. First and second reservoirs can also be disposed within the enclosure and adapted to contain one or more reagents therein. A first valve can be disposed within the enclosure and in fluid communication with the first reservoir, the second reservoir, or both. The first valve can also be in fluid communication with the first or second membranes or both. The first valve can be adapted to selectively regulate the flow of the reagents from the first reservoir, through at least one of the first and second membranes, and into the second reservoir.

  6. Qualification Tests for the Air Sampling System at the 296-Z-7 Stack

    SciTech Connect

    Glissmeyer, John A; Maughan, A David

    2001-10-15

    This report documents tests performed to verify that the monitoring system for the 296-Z-7 ventilation stack meets the applicable regulatory criteria regarding the placement of the air sampling probe, sample transport, and stack flow measurement accuracy.

  7. Spectral fingerprinting of polycyclic aromatic hydrocarbons in high-volume ambient air samples by constant energy synchronous luminescence spectroscopy

    USGS Publications Warehouse

    Kerkhoff, M.J.; Lee, T.M.; Allen, E.R.; Lundgren, D.A.; Winefordner, J.D.

    1985-01-01

    A high-volume sampler fitted with a glass-fiber filter and backed by polyurethane foam (PUF) was employed to collect airborne particulate and gas-phase polycylic aromatic hydrocarbons (PAHs) in ambient air. Samples were collected from four sources representing a range of environmental conditions: gasoline engine exhaust, diesel engine exhaust, air near a heavily traveled interstate site, and air from a moderately polluted urban site. Spectral fingerprints of the unseparated particulate and gas-phase samples were obtained by constant energy synchronous luminescence spectroscopy (CESLS). Five major PAHs in the gas-phase extracts were characterized and estimated. The compatibility of a high-volume sampling method using polyurethane foam coupled with CESLS detection is explored for use as a screening technique for PAHs in ambient air. ?? 1985 American Chemical Society.

  8. Stationary source sampling report: Volatile organic compounds testing, 300-M area air stripper exhaust stack

    SciTech Connect

    Not Available

    1985-11-25

    An air stripping column was used in the 300-M area to remove volatile organic compounds from contaminated groundwater. Tests were performed October 29, 1985, at the air stripper exhaust stack to measure the emissions of tetrachloroethylene, trichloroethylene, and 1,1,1-trichloroethane for compliance purposes. Three absorbent sampling train (AST) runs (yielding duplicate samples for each run) and three velocity traverses were performed at the air stripper exhaust stack. Ambient air sampling was not performed as scheduled because of inclement weather conditions.

  9. Microbial air-sampling equipment, part 2: experiences of compounding pharmacists.

    PubMed

    Mixon, Bill; Cabaleiro, Joe; Latta, Kenneth S

    2008-01-01

    The most recent changes to Chapter 797 of the United States Pharmacopeia-National Formulary initiated an intense controversy about the frequency of cleanroom air sampling that is required to prevent the contamination of sterile preparations. For compounders who must purchase an air sampler to use in the cleanroom, choices abound. This article summarizes discussions from compounding pharmacists and their experiences with air sampling devices.

  10. Toxicological Assessment of ISS Air Quality: Contingency Sampling - February 2013

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2013-01-01

    Two grab sample containers (GSCs) were collected by crew members onboard ISS in response to a vinegar-like odor in the US Lab. On February 5, the first sample was collected approximately 1 hour after the odor was noted by the crew in the forward portion of the Lab. The second sample was collected on February 22 when a similar odor was noted and localized to the end ports of the microgravity science glovebox (MSG). The crewmember removed a glove from the MSG and collected the GSC inside the glovebox volume. Both samples were returned on SpaceX-2 for ground analysis.

  11. Sampling size in the verification of manufactured-supplied air kerma strengths

    SciTech Connect

    Ramos, Luis Isaac; Martinez Monge, Rafael

    2005-11-15

    Quality control mandate that the air kerma strengths (S{sub K}) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to an a priori statistical level of uncertainty. The results are based on the assumption that the S{sub K} has a normal distribution. To demonstrate this, the S{sub K} of each of the seeds measured was corrected to ensure that the average S{sub K} of its sample remained the same. In this process 2030 results were collected and analyzed using a normal plot. In our opinion, the number of seeds sampled should be determined beforehand according to an a priori level of statistical uncertainty.

  12. Relationship of air sampling rates of semipermeable membrane devices with the properties of organochlorine pesticides.

    PubMed

    Zhu, Xiuhua; Ding, Guanghui; Levy, Walkiria; Jakobi, Gert; Schramm, Karl-Werner

    2011-06-01

    The organochlorine pesticides (OCP) in Eastern-Barvaria at Haidel 1160 m a.s.l. were monitored with a low volume active air sampler and semi-permeable membrane devices (SPMD). The air sampling rates (Rair) of SPMD for OCP were calculated. Quantitative structure-property relationship (QSPR) models of Rair of SPMD were developed for OCP with partial least square (PLS) regression. Quantum chemical descriptors computed by semi-empirical PM6 method were used as predictor variables. The cumulative variance of the dependent variable explained by the PLS components and determined by cross-validation (Q(2)cum), for the optimal models, is 0.637, indicating that the model has good predictive ability and robustness, and could be used to estimate Rair values of OCP. The main factors governing Rair of OCP are intermolecular interactions and the energy required for cave-forming in dissolution of OCP into triolein of SPMD.

  13. Biomimetic air sampling for detection of low concentrations of molecules and bioagents : LDRD 52744 final report.

    SciTech Connect

    Hughes, Robert Clark

    2003-12-01

    Present methods of air sampling for low concentrations of chemicals like explosives and bioagents involve noisy and power hungry collectors with mechanical parts for moving large volumes of air. However there are biological systems that are capable of detecting very low concentrations of molecules with no mechanical moving parts. An example is the silkworm moth antenna which is a highly branched structure where each of 100 branches contains about 200 sensory 'hairs' which have dimensions of 2 microns wide by 100 microns long. The hairs contain about 3000 pores which is where the gas phase molecules enter the aqueous (lymph) phase for detection. Simulations of diffusion of molecules indicate that this 'forest' of hairs is 'designed' to maximize the extraction of the vapor phase molecules. Since typical molecules lose about 4 decades in diffusion constant upon entering the liquid phase, it is important to allow air diffusion to bring the molecule as close to the 'sensor' as possible. The moth acts on concentrations as low as 1000 molecules per cubic cm. (one part in 1e16). A 3-D collection system of these dimensions could be fabricated by micromachining techniques available at Sandia. This LDRD addresses the issues involved with extracting molecules from air onto micromachined structures and then delivering those molecules to microsensors for detection.

  14. Filter for on-line air monitor unaffected by radon progeny and method of using same

    DOEpatents

    Phillips, Terrance D.; Edwards, Howard D.

    1999-01-01

    An apparatus for testing air having contaminants and radon progeny therein. The apparatus includes a sampling box having an inlet for receiving the air and an outlet for discharging the air. The sampling box includes a filter made of a plate of sintered stainless steel. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough. A method of testing air having contaminants and radon progeny therein. The method includes providing a testing apparatus that has a sampling box with an inlet for receiving the air and an outlet for discharging the air, and has a sintered stainless steel filter disposed within said sampling box; drawing air from a source into the sampling box using a vacuum pump; passing the air through the filter; monitoring the contaminants trapped by the filter; and providing an alarm when a selected level of contaminants is reached. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough.

  15. Secondary air injection system and method

    SciTech Connect

    Wu, Ko-Jen; Walter, Darrell J.

    2014-08-19

    According to one embodiment of the invention, a secondary air injection system includes a first conduit in fluid communication with at least one first exhaust passage of the internal combustion engine and a second conduit in fluid communication with at least one second exhaust passage of the internal combustion engine, wherein the at least one first and second exhaust passages are in fluid communication with a turbocharger. The system also includes an air supply in fluid communication with the first and second conduits and a flow control device that controls fluid communication between the air supply and the first conduit and the second conduit and thereby controls fluid communication to the first and second exhaust passages of the internal combustion engine.

  16. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-02-17

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self

  17. Comparison of stationary and personal air sampling with an air dispersion model for children's ambient exposure to manganese.

    PubMed

    Fulk, Florence; Haynes, Erin N; Hilbert, Timothy J; Brown, David; Petersen, Dan; Reponen, Tiina

    2016-09-01

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to assess exposure for children enrolled in the Communities Actively Researching Exposure Study in Marietta, OH. Ambient air Mn concentration values were modeled using US Environmental Protection Agency's Air Dispersion Model AERMOD based on emissions from the ferromanganese refinery located in Marietta. Modeled Mn concentrations were compared with Mn concentrations from a nearby stationary air monitor. The Index of Agreement for modeled versus monitored data was 0.34 (48 h levels) and 0.79 (monthly levels). Fractional bias was 0.026 for 48 h levels and -0.019 for monthly levels. The ratio of modeled ambient air Mn to measured ambient air Mn at the annual time scale was 0.94. Modeled values were also time matched to personal air samples for 19 children. The modeled values explained a greater degree of variability in personal exposures compared with time-weighted distance from the emission source. Based on these results modeled Mn concentrations provided a suitable approach for assessing airborne Mn exposure in this cohort. PMID:27168393

  18. Comparison of stationary and personal air sampling with an air dispersion model for children's ambient exposure to manganese.

    PubMed

    Fulk, Florence; Haynes, Erin N; Hilbert, Timothy J; Brown, David; Petersen, Dan; Reponen, Tiina

    2016-09-01

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to assess exposure for children enrolled in the Communities Actively Researching Exposure Study in Marietta, OH. Ambient air Mn concentration values were modeled using US Environmental Protection Agency's Air Dispersion Model AERMOD based on emissions from the ferromanganese refinery located in Marietta. Modeled Mn concentrations were compared with Mn concentrations from a nearby stationary air monitor. The Index of Agreement for modeled versus monitored data was 0.34 (48 h levels) and 0.79 (monthly levels). Fractional bias was 0.026 for 48 h levels and -0.019 for monthly levels. The ratio of modeled ambient air Mn to measured ambient air Mn at the annual time scale was 0.94. Modeled values were also time matched to personal air samples for 19 children. The modeled values explained a greater degree of variability in personal exposures compared with time-weighted distance from the emission source. Based on these results modeled Mn concentrations provided a suitable approach for assessing airborne Mn exposure in this cohort.

  19. Review of the Physical Science Facility Stack Air Sampling Probe Locations

    SciTech Connect

    Glissmeyer, John A.

    2007-09-30

    This letter report reviews compliance of the current design of the Physical Science Facility (PSF) stack air sampling locations with the ANSI/HPS N13.1-1999 standard. The review was based on performance criteria used for locating air sampling probes, the design documents provided and available information on systems previously tested for compliance with the criteria. Recommendations are presented for ways to bring the design into compliance with the requirements for the sampling probe placement.

  20. A comparison of the HTO air sampling techniques

    SciTech Connect

    Bishop, C.T.; Carfayno, D.G.; Farmer, B.M.; Lacy, V.C.; Yanko, W.H.

    1985-09-01

    Monsanto Research Corporation, a Department of Energy contractor, monitors for tritium oxide as an integral part of the routine environmental surveillance program. The glycol bubbler method has been used at Mound since 1971 instead of the silica gel collection techniques used at many other DOE facilities. With the glycol bubbler method, ethylene glycol is used to collect water vapor for the HTO analysis. Data from both methods are compared and the advantages of the glycol bubbler method are presented.

  1. Recent advances in thermal desorption-gas chromatography-mass spectrometery method to eliminate the matrix effect between air and water samples: application to the accurate determination of Henry's law constant.

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2014-05-16

    Accurate values for the Henry's law constants are essential to describe the environmental dynamics of a solute, but substantial errors are recognized in many reported data due to practical difficulties in measuring solubility and/or vapor pressure. Despite such awareness, validation of experimental approaches has scarcely been made. An experimental approach based on thermal desorption-gas chromatography-mass spectrometery (TD-GC-MS) method was developed to concurrently allow the accurate determination of target compounds from the headspace and aqueous samples in closed equilibrated system. The analysis of six aromatics and eight non-aromatic oxygenates was then carried out in a static headspace mode. An estimation of the potential bias and mass balance (i.e., sum of mass measured individually from gas and liquid phases vs. the mass initially added to the system) demonstrates compound-specific phase dependency so that the best results are obtained by aqueous (less soluble aromatics) and headspace analysis (more soluble non-aromatics). Accordingly, we were able to point to the possible sources of biases in previous studies and provide the best estimates for the Henry's constants (Matm(-1)): benzene (0.17), toluene (0.15), p-xylene (0.13), m-xylene (0.13), o-xylene (0.19), styrene (0.27); propionaldehyde (9.26), butyraldehyde (6.19), isovaleraldehyde (2.14), n-valeraldehyde (3.98), methyl ethyl ketone (10.5), methyl isobutyl ketone (3.93), n-butyl acetate (2.41), and isobutyl alcohol (22.2).

  2. Recent advances in thermal desorption-gas chromatography-mass spectrometery method to eliminate the matrix effect between air and water samples: application to the accurate determination of Henry's law constant.

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2014-05-16

    Accurate values for the Henry's law constants are essential to describe the environmental dynamics of a solute, but substantial errors are recognized in many reported data due to practical difficulties in measuring solubility and/or vapor pressure. Despite such awareness, validation of experimental approaches has scarcely been made. An experimental approach based on thermal desorption-gas chromatography-mass spectrometery (TD-GC-MS) method was developed to concurrently allow the accurate determination of target compounds from the headspace and aqueous samples in closed equilibrated system. The analysis of six aromatics and eight non-aromatic oxygenates was then carried out in a static headspace mode. An estimation of the potential bias and mass balance (i.e., sum of mass measured individually from gas and liquid phases vs. the mass initially added to the system) demonstrates compound-specific phase dependency so that the best results are obtained by aqueous (less soluble aromatics) and headspace analysis (more soluble non-aromatics). Accordingly, we were able to point to the possible sources of biases in previous studies and provide the best estimates for the Henry's constants (Matm(-1)): benzene (0.17), toluene (0.15), p-xylene (0.13), m-xylene (0.13), o-xylene (0.19), styrene (0.27); propionaldehyde (9.26), butyraldehyde (6.19), isovaleraldehyde (2.14), n-valeraldehyde (3.98), methyl ethyl ketone (10.5), methyl isobutyl ketone (3.93), n-butyl acetate (2.41), and isobutyl alcohol (22.2). PMID:24704185

  3. Method and apparatus for extracting water from air

    DOEpatents

    Spletzer, Barry L.; Callow, Diane Schafer; Marron, Lisa C.; Salton, Jonathan R.

    2002-01-01

    The present invention provides a method and apparatus for extracting liquid water from moist air using minimal energy input. The method comprises compressing moist air under conditions that foster the condensation of liquid water. The air can be decompressed under conditions that do not foster the vaporization of the condensate. The decompressed, dried air can be exchanged for a fresh charge of moist air and the process repeated. The liquid condensate can be removed for use. The apparatus can comprise a compression chamber having a variable internal volume. An intake port allows moist air into the compression chamber. An exhaust port allows dried air out of the compression chamber. A condensation device fosters condensation at the desired conditions. A condensate removal port allows liquid water to be removed.

  4. Method and apparatus for extracting water from air

    DOEpatents

    Spletzer, Barry L.

    2001-01-01

    The present invention provides a method and apparatus for extracting liquid water from moist air using minimal energy input. The method comprises compressing moist air under conditions that foster the condensation of liquid water (ideally isothermal to a humidity of 1.0, then adiabatic thereafter). The air can be decompressed under conditions that do not foster the vaporization of the condensate. The decompressed, dried air can be exchanged for a fresh charge of moist air and the process repeated. The liquid condensate can be removed for use. The apparatus can comprise a compression chamber having a variable internal volume. An intake port allows moist air into the compression chamber. An exhaust port allows dried air out of the compression chamber. A condensation device fosters condensation at the desired conditions. A condensate removal port allows liquid water to be removed.

  5. Assessment of Flatbed Scanner Method for Quality Assurance Testing of Air Content and Spacing Factor in Concrete

    NASA Astrophysics Data System (ADS)

    Nezami, Sona

    The flatbed scanner method for air void analysis of concrete is investigated through a comparison study with the standard ASTM C457 manual and Rapid Air 457 test methods. Air void parameters including air content and spacing factor are determined by image analysis of a large population of scanned samples through contrast enhancement and threshold determination procedures. It is shown that flatbed scanner method is giving comparable results to manual and Rapid Air 457 methods. Furthermore, a comparison of the air void chord length distributions obtained from the two methods of flatbed scanner and Rapid Air 457 has been implemented in this research. The effect of having different settings in the scanning process of scanner method is also investigated. Moreover, a threshold study has been performed that showed the flatbed scanner method can be employed in combination with manual and Rapid Air 457 methods as a time and cost saving strategy.

  6. Release of Free DNA by Membrane-Impaired Bacterial Aerosols Due to Aerosolization and Air Sampling

    PubMed Central

    Zhen, Huajun; Han, Taewon; Fennell, Donna E.

    2013-01-01

    We report here that stress experienced by bacteria due to aerosolization and air sampling can result in severe membrane impairment, leading to the release of DNA as free molecules. Escherichia coli and Bacillus atrophaeus bacteria were aerosolized and then either collected directly into liquid or collected using other collection media and then transferred into liquid. The amount of DNA released was quantified as the cell membrane damage index (ID), i.e., the number of 16S rRNA gene copies in the supernatant liquid relative to the total number in the bioaerosol sample. During aerosolization by a Collison nebulizer, the ID of E. coli and B. atrophaeus in the nebulizer suspension gradually increased during 60 min of continuous aerosolization. We found that the ID of bacteria during aerosolization was statistically significantly affected by the material of the Collison jar (glass > polycarbonate; P < 0.001) and by the bacterial species (E. coli > B. atrophaeus; P < 0.001). When E. coli was collected for 5 min by filtration, impaction, and impingement, its ID values were within the following ranges: 0.051 to 0.085, 0.16 to 0.37, and 0.068 to 0.23, respectively; when it was collected by electrostatic precipitation, the ID values (0.011 to 0.034) were significantly lower (P < 0.05) than those with other sampling methods. Air samples collected inside an equine facility for 2 h by filtration and impingement exhibited ID values in the range of 0.30 to 0.54. The data indicate that the amount of cell damage during bioaerosol sampling and the resulting release of DNA can be substantial and that this should be taken into account when analyzing bioaerosol samples. PMID:24096426

  7. Continuous air monitoring apparatus and method

    SciTech Connect

    Sides, G.D.; Cates, M.

    1992-01-01

    A continuous air monitoring apparatus utilizes a solid sorbent preconcentrator to concentrate airborne sorbent compounds to gas chromatographic analysis. Direct connection between the preconcentrator and gas chromatographic column allows direct desorption of the compounds into the column with minimal dead space. Temperature control on the column allows sharp chromatographic peaks to be attained without cryogenic focusing.

  8. ANASORB{reg_sign} 747 - A universal sorbent for air sampling?

    SciTech Connect

    Harper, M.

    1997-12-31

    A sorbent to be used for air sampling must meet certain performance criteria including sample background, capacity, stability, and recovery. Anasorb{sup R} 747 is a proprietary 20/40 mesh beaded active carbon prepared from raw materials with a very low ash content in a process which creates a regular pore structure. The background is very low for both inorganic and organic species, and the surface is more inert and less hydrophilic than coconut charcoal, while capacity is similar. The low catalytic activity of the surface means samples of many reactive compounds remain stable for longer periods. The sorbent is compatible with most solvent systems in use (e.g. carbon disulfide, methylene chloride, methanol, dimethyformamide). Anasorb 747 can be coated with chemicals for efficient adsorption of inorganic gases, which can be analyzed at very low levels because of low background interference. A large number of validated sampling methods use Anasorb 747, including methods from OSHA and NIOSH, corporate industrial hygiene laboratories, various branches of the EPA, and international agencies. These methods refer to around fifty different gases and vapors. Although this sorbent is not compatible with some compounds (e.g. low molecular weight aldehydes) it is quite close to being of universal application.

  9. Artifact free denuder method for sampling of carbonaceous aerosols

    NASA Astrophysics Data System (ADS)

    Mikuška, P.; Vecera, Z.; Broškovicová, A.

    2003-04-01

    Over the past decade, a growing attention has been focused on the carbonaceous aerosols. Although they may account for 30--60% of the total fine aerosol mass, their concentration and formation mechanisms are not well understood, particularly in comparison with major fine particle inorganic species. The deficiency in knowledge of carbonaceous aerosols results from their complexity and because of problems associated with their collection. Conventional sampling techniques of the carbonaceous aerosols, which utilize filters/backup adsorbents suffer from sampling artefacts. Positive artifacts are mainly due to adsorption of gas-phase organic compounds by the filter material or by the already collected particles, whereas negative artifacts arise from the volatilisation of already collected organic compounds from the filter. Furthermore, in the course of the sampling, the composition of the collected organic compounds may be modified by oxidants (O_3, NO_2, PAN, peroxides) that are present in the air passing through the sampler. It is clear that new, artifact free, method for sampling of carbonaceous aerosols is needed. A combination of a diffusion denuder and a filter in series is very promising in this respect. The denuder is expected to collect gaseous oxidants and gas-phase organic compounds from sample air stream prior to collection of aerosol particles on filters, and eliminate thus both positive and negative sampling artifacts for carbonaceous aerosols. This combination is subject of the presentation. Several designs of diffusion denuders (cylindrical, annular, parallel plate, multi-channel) in combination with various types of wall coatings (dry, liquid) were examined. Special attention was given to preservation of the long-term collection efficiency. Different adsorbents (activated charcoal, molecular sieve, porous polymers) and sorbents coated with various chemical reagents (KI, Na_2SO_3, MnO_2, ascorbic acid) or chromatographic stationary phases (silicon oils

  10. Automated air-void system characterization of hardened concrete: Helping computers to count air-voids like people count air-voids---Methods for flatbed scanner calibration

    NASA Astrophysics Data System (ADS)

    Peterson, Karl

    Since the discovery in the late 1930s that air entrainment can improve the durability of concrete, it has been important for people to know the quantity, spacial distribution, and size distribution of the air-voids in their concrete mixes in order to ensure a durable final product. The task of air-void system characterization has fallen on the microscopist, who, according to a standard test method laid forth by the American Society of Testing and Materials, must meticulously count or measure about a thousand air-voids per sample as exposed on a cut and polished cross-section of concrete. The equipment used to perform this task has traditionally included a stereomicroscope, a mechanical stage, and a tally counter. Over the past 30 years, with the availability of computers and digital imaging, automated methods have been introduced to perform the same task, but using the same basic equipment. The method described here replaces the microscope and mechanical stage with an ordinary flatbed desktop scanner, and replaces the microscopist and tally counter with a personal computer; two pieces of equipment much more readily available than a microscope with a mechanical stage, and certainly easier to find than a person willing to sit for extended periods of time counting air-voids. Most laboratories that perform air-void system characterization typically have cabinets full of prepared samples with corresponding results from manual operators. Proponents of automated methods often take advantage of this fact by analyzing the same samples and comparing the results. A similar iterative approach is described here where scanned images collected from a significant number of samples are analyzed, the results compared to those of the manual operator, and the settings optimized to best approximate the results of the manual operator. The results of this calibration procedure are compared to an alternative calibration procedure based on the more rigorous digital image accuracy

  11. Summary of gamma spectrometry on local air samples from 1985--1995

    SciTech Connect

    Winn, W.G.

    1997-04-02

    This report summarizes the 1985--1995 results of low-level HPGe gamma spectrometry analysis of high-volume air samples collected at the Aiken Airport, which is about 25 miles north of SRS. The author began analyzing these samples with new calibrations using the newly developed GRABGAM code in 1985. The air sample collections were terminated in 1995, as the facilities at the Aiken Airport were no longer available. Air sample measurements prior to 1985 were conducted with a different analysis system (and by others prior to 1984), and the data were not readily available. The report serves to closeout this phase of local NTS air sample studies, while documenting the capabilities and accomplishments. Hopefully, the information will guide other applications for this technology, both locally and elsewhere.

  12. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-104 at the Conclusion of 7A

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-l04 (7 A) flight to the ISS is reported. ISS air samples were taken in June and July 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Atlantis using GSCs. Solid sorbent air sampler (SSAS) samples were obtained from the ISS in April, June, and July. Analytical methods have not changed from earlier reports, and all quality control measures were met.

  13. Solvent-free sampling with di-n-butylamine for monitoring of isocyanates in air.

    PubMed

    Marand, Asa; Karlsson, Daniel; Dalene, Marianne; Skarping, Gunnar

    2005-04-01

    The solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar amounts of di-n-butylamine (DBA) and acetic acid. Air sampling was performed with an air flow of 0.2 l min(-1). The formed isocyanate-DBA derivatives were determined using liquid chromatography and tandem mass spectrometry. The sampler was investigated in regard to collection principle and extraction of the formed derivatives with good results. The possibility to store the sampler before sampling and to perform long-term sampling was demonstrated. Field extraction of the sampler was not necessary, as there was no difference between immediately extracted samples and stored ones (2 days). In comparative studies, the sampler was evaluated against a reference method, impinger-filter sampling with DBA as reagent. The ratios between the results obtained with the sampler and the reference in a test chamber at a relative humidity (RH) of 45% was in the range of 83-109% for isocyanates formed during thermal decomposition of PUR. At RH 95%, the range was 72-101% with the exception of isocyanic acid. In two field evaluations, the ratios for fast curing 2,4'- and 4,4'-methylene bisphenyl diisocyanate (MDI) was in the range 81-113% and for the 3-ring MDI the range was 54-70%. For the slower curing 1,6-hexamethylene diisocyanate (HDI) and HDI isocyanurate, the ratios were in the range 78-145%. In conclusion, the solvent-free sampler is a convenient alternative in most applications to the more cumbersome impinger-filter sampler.

  14. Aerostat-lofted instrument and sampling method for determination of emissions from open area sources

    EPA Science Inventory

    An aerostat-borne instrument and sampling method was developed to characterize air samples from area sources, such as emissions from open burning. The 10 kg battery-powered instrument system, termed "the Flyer," is lofted with a helium-filled aerostat of 4 m nominal diameter and ...

  15. Dispersion modeling of selected PAHs in urban air: A new approach combining dispersion model with GIS and passive air sampling

    NASA Astrophysics Data System (ADS)

    Sáňka, Ondřej; Melymuk, Lisa; Čupr, Pavel; Dvorská, Alice; Klánová, Jana

    2014-10-01

    This study introduces a new combined air concentration measurement and modeling approach that we propose can be useful in medium and long term air quality assessment. A dispersion study was carried out for four high molecular weight polycyclic aromatic hydrocarbons (PAHs) in an urban area with industrial, traffic and domestic heating sources. A geographic information system (GIS) was used both for processing of input data as well as visualization of the modeling results. The outcomes of the dispersion model were compared to the results of passive air sampling (PAS). Despite discrepancies between measured and modeled concentrations, an approach combining the two techniques is promising for future air quality assessment. Differences between measured and modeled concentrations, in particular when measured values exceed the modeled concentrations, are indicative of undocumented, sporadic pollutant sources. Thus, these differences can also be useful for assessing and refining emission inventories.

  16. Automated syringe sampler. [remote sampling of air and water

    NASA Technical Reports Server (NTRS)

    Purgold, G. C. (Inventor)

    1981-01-01

    A number of sampling services are disposed in a rack which slides into a housing. In response to a signal from an antenna, the circutry elements are activated which provide power individually, collectively, or selectively to a servomechanism thereby moving an actuator arm and the attached jawed bracket supporting an evaculated tube towards a stationary needle. One open end of the needle extends through the side wall of a conduit to the interior and the other open end is maintained within the protective sleeve, supported by a bifurcated bracket. A septum in punctured by the end of the needle within the sleeve and a sample of the fluid medium in the conduit flows through the needle and is transferred to a tube. The signal to the servo is then reversed and the actuator arm moves the tube back to its original position permitting the septum to expand and seal the hole made by the needle. The jawed bracket is attached by pivot to the actuator to facilitate tube replacement.

  17. Estimation of sampling error uncertainties in observed surface air temperature change in China

    NASA Astrophysics Data System (ADS)

    Hua, Wei; Shen, Samuel S. P.; Weithmann, Alexander; Wang, Huijun

    2016-06-01

    This study examines the sampling error uncertainties in the monthly surface air temperature (SAT) change in China over recent decades, focusing on the uncertainties of gridded data, national averages, and linear trends. Results indicate that large sampling error variances appear at the station-sparse area of northern and western China with the maximum value exceeding 2.0 K2 while small sampling error variances are found at the station-dense area of southern and eastern China with most grid values being less than 0.05 K2. In general, the negative temperature existed in each month prior to the 1980s, and a warming in temperature began thereafter, which accelerated in the early and mid-1990s. The increasing trend in the SAT series was observed for each month of the year with the largest temperature increase and highest uncertainty of 0.51 ± 0.29 K (10 year)-1 occurring in February and the weakest trend and smallest uncertainty of 0.13 ± 0.07 K (10 year)-1 in August. The sampling error uncertainties in the national average annual mean SAT series are not sufficiently large to alter the conclusion of the persistent warming in China. In addition, the sampling error uncertainties in the SAT series show a clear variation compared with other uncertainty estimation methods, which is a plausible reason for the inconsistent variations between our estimate and other studies during this period.

  18. [Problems in sampling the polycyclic aromatic hydrocarbons and air-dispersed particles].

    PubMed

    Pozzoli, L; Cottica, D

    1984-01-01

    Polynuclear aromatic hydrocarbons (PAH) are difficult to monitor and quantify. This study has been worked-out to evaluate various sampling methods for monitoring PAH in the work environment: the sampling devices were tested on the field in a carbon electrodes factory. During the field surveys we used the following sampling procedures that actually are the most adopted: Glass fiber filter, Silver membrane (Teflon, cellulosic esters), The over mentioned membrane filters followed by solid substrate (Amberlite XAD-2). For the analytical quantification we followed this procedure: PAH s extraction from membranes and resins by solvent in ultrasonic bath; quantification by GS-MS (single ion monitor, capillary column, on column injection). Results of field testing show that for completely retain PAHs during air sampling in work environment it is necessary to use a membrane filter followed by a back-up tube of Amberlite-XAD-2 resin: the use of this sampling device is particularly recommended during monitoring of work operations with temperature greater than or equal to 150 degrees C involving coke oven procedure, charcoal production, asphalt production, petroleum coking operations.

  19. Variables Related to Pre-Service Cannabis Use in a Sample of Air Force Enlistees.

    ERIC Educational Resources Information Center

    Mullins, Cecil J.; And Others

    This report is an attempt to add to the existing information about cannabis use, its correlates, and its effects. The sample population consisted of self-admitted abusers of various drugs, identified shortly after entering the Air Force. The subjects (N=4688) were located through the Drug Control Office at Lackland Air Force Base. Variables…

  20. Salmonella recovery following air chilling for matched neck-skin and whole carcass sampling methodologies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The prevalence and serogroups of Salmonella recovered following air chilling were determined for both enriched neck skin and matching enriched whole carcass samples. Commercially processed and eviscerated carcasses were air chilled to 4C before removing the neck skin (8.3 g) and stomaching in 83 mL...

  1. System and method for extracting a sample from a surface

    DOEpatents

    Van Berkel, Gary; Covey, Thomas

    2015-06-23

    A system and method is disclosed for extracting a sample from a sample surface. A sample is provided and a sample surface receives the sample which is deposited on the sample surface. A hydrophobic material is applied to the sample surface, and one or more devices are configured to dispense a liquid on the sample, the liquid dissolving the sample to form a dissolved sample material, and the one or more devices are configured to extract the dissolved sample material from the sample surface.

  2. Sampling, storage, and analysis of C2-C7 non-methane hydrocarbons from the US National Oceanic and Atmospheric Administration Cooperative Air Sampling Network glass flasks.

    PubMed

    Pollmann, Jan; Helmig, Detlev; Hueber, Jacques; Plass-Dülmer, Christian; Tans, Pieter

    2008-04-25

    An analytical technique was developed to analyze light non-methane hydrocarbons (NMHC), including ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane, n-hexane, isoprene, benzene and toluene from whole air samples collected in 2.5l-glass flasks used by the National Oceanic and Atmospheric Administration, Earth System Research Laboratory, Global Monitoring Division (NOAA ESRL GMD, Boulder, CO, USA) Cooperative Air Sampling Network. This method relies on utilizing the remaining air in these flasks (which is at below-ambient pressure at this stage) after the completion of all routine greenhouse gas measurements from these samples. NMHC in sample aliquots extracted from the flasks were preconcentrated with a custom-made, cryogen-free inlet system and analyzed by gas chromatography (GC) with flame ionization detection (FID). C2-C7 NMHC, depending on their ambient air mixing ratios, could be measured with accuracy and repeatability errors of generally < or =10-20%. Larger deviations were found for ethene and propene. Hexane was systematically overestimated due to a chromatographic co-elution problem. Saturated NMHC showed less than 5% changes in their mixing ratios in glass flask samples that were stored for up to 1 year. In the same experiment ethene and propene increased at approximately 30% yr(-1). A series of blank experiments showed negligible contamination from the sampling process and from storage (<10 pptv yr(-1)) of samples in these glass flasks. Results from flask NMHC analyses were compared to in-situ NMHC measurements at the Global Atmospheric Watch station in Hohenpeissenberg, Germany. This 9-months side-by-side comparison showed good agreement between both methods. More than 94% of all data comparisons for C2-C5 alkanes, isoprene, benzene and toluene fell within the combined accuracy and precision objectives of the World Meteorological Organization Global Atmosphere Watch (WMO-GAW) for NMHC measurements.

  3. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    SciTech Connect

    Langton, C. A.; Almond, P. M.

    2013-11-26

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO{sub 4}{sup -} in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O{sub 4}{sup -}, which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The

  4. TECHNOLOGY EVALUATION REPORT CEREX ENVIRONMENTAL SERVICES UV HOUND POINT SAMPLE AIR MONITOR

    EPA Science Inventory

    The USEPA's National Homeland Security Research Center (NHSRC) Technology Testing and Evaluation Program (TTEP) is carrying out performance tests on homeland security technologies. Under TTEP, Battelle evaluated the performance of the Cerex UV Hound point sample air monitor in de...

  5. NEW APPLICATION OF PASSIVE SAMPLING DEVICES FOR ASSESSMENT OF RESPIRATORY EXPOSURE TO PESTICIDES IN INDOOR AIR

    EPA Science Inventory

    The United States Environmental Protection Agency (EPA) has long maintained an interest in potential applications of passive sampling devices (PSDs) for estimating the concentrations of various pollutants in air. Typically PSDs were designed for the workplace monitoring of vola...

  6. Comparison of stationary and personal air sampling with an air dispersion model for children’s ambient exposure to manganese

    EPA Science Inventory

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to asse...

  7. Assessment of dust sampling methods for the study of cultivable-microorganism exposure in stables.

    PubMed

    Normand, Anne-Cécile; Vacheyrou, Mallory; Sudre, Bertrand; Heederik, Dick J J; Piarroux, Renaud

    2009-12-01

    Studies have shown a link between living on a farm, exposure to microbial components (e.g., endotoxins or beta-d-glucans), and a lower risk for allergic diseases and asthma. Due to the lack of validated sampling methods, studies of asthma and atopy have not relied on exposure assessment based on culture techniques. Our objective was therefore to compare several dust sampling methods for the detection of cultivable-microorganism exposure in stables. Sixteen French farms were sampled using four different methods: (i) active air sampling using a pump, (ii) passive dust sampling with a plastic box, (iii) dust sampling with an electrostatic dust fall collector (wipe), and (iv) dust sampling using a spatula to collect dust already settled on a windowsill. The results showed that collection of settled dust samples with either plastic boxes or wipes was reproducible (pairwise correlations, 0.72 and 0.73, respectively) and resulted in highly correlated results (pairwise correlation between the two methods, 0.82). We also found that settled dust samples collected with a plastic box correctly reflected the composition of the samples collected in the air of the stable when there was no farmer activity. A loss of microbial diversity was observed when dust was kept for 3 months at room temperature. We therefore conclude that measurement of viable microorganisms within a reasonable time frame gives an accurate representation of the microbial composition of stable air.

  8. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration. PMID:21793731

  9. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.

  10. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Service, Dairy Programs, or Official Methods of Analysis of the Association of Analytical Chemists or... 7 Agriculture 3 2011-01-01 2011-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods...

  11. BIBLE A whole-air sampling as a window on Asian biogeochemistry

    NASA Astrophysics Data System (ADS)

    Elliott, Scott; Blake, Donald R.; Blake, Nicola J.; Dubey, Manvendra K.; Rowland, F. Sherwood; Sive, Barkley C.; Smith, Felisa A.

    2003-02-01

    Asian trace gas and aerosol emissions into carbon, nitrogen, and other elemental cycles will figure prominently in near term Earth system evolution. Atmospheric hydrocarbon measurements resolve numerous chemical species and can be used to investigate sourcing for key geocarriers. A recent aircraft study of biomass burning and lightning (BIBLE A) explored the East Asian atmosphere and was unique in centering on the Indonesian archipelago. Samples of volatile organics taken over/between the islands of Japan, Saipan, Java, and Borneo are here examined as a guide to whole-air-based studies of future Asian biogeochemistry. The midlatitude onshore/offshore pulse and tropical convection strongly influence concentration distributions. As species of increasing molecular weight are considered, rural, combustion, and industrial source regimes emerge. Methane-rich inputs such as waste treatment and rice cultivation are evidenced in the geostrophic outflow. The Indonesian atmosphere is rich in biomass burning markers and also those of vehicular activity. Complexity of air chemistry in the archipelago is a direct reflection of diverse topography, land use, and local economies in a rapidly developing nation. Conspicuous in its absence is the fingerprint for liquefied petroleum gas leakage, but it can be expected to appear as demand for clean fossil fuels rises along with per capita incomes. Combustion tracers indicate high nitrogen mobilization rates, linking regional terrestrial geocycles with open marine ecosystems. Sea to air fluxes are superimposed on continental and marine backgrounds for the methyl halides. However, ocean hot spots are not coordinated and suggest an intricate subsurface kinetics. Levels of long-lived anthropogenic halocarbons attest to the success of international environmental treaties while reactive chlorine containing species track industrial air masses. The dozens of hydrocarbons resolvable by gas chromatographic methods will enable monitoring of

  12. Potassium bromide method of infrared sampling

    USGS Publications Warehouse

    Milkey, R.G.

    1958-01-01

    In the preparation of potassium bromide pressed windows for use in the infrared analysis of solids, severe grinding of the potassium bromide powder may produce strong absorption bands that could interfere seriously with the spectra of the sample. These absorption bands appear to be due to some crystal alteration of the potassium bromide as a result of the grinding process. They were less apt to occur when the coarser powder, which had received a relatively gentle grinding, was used. Window blanks prepared from the coarser powders showed smaller adsorbed water peaks and generally higher over-all transmittance readings than windows pressed from the very fine powders.

  13. Fast detection of air contaminants using immunobiological methods

    NASA Astrophysics Data System (ADS)

    Schmitt, Katrin; Bolwien, Carsten; Sulz, Gerd; Koch, Wolfgang; Dunkhorst, Wilhelm; Lödding, Hubert; Schwarz, Katharina; Holländer, Andreas; Klockenbring, Torsten; Barth, Stefan; Seidel, Björn; Hofbauer, Wolfgang; Rennebarth, Torsten; Renzl, Anna

    2009-05-01

    The fast and direct identification of possibly pathogenic microorganisms in air is gaining increasing interest due to their threat for public health, e.g. in clinical environments or in clean rooms of food or pharmaceutical industries. We present a new detection method allowing the direct recognition of relevant germs or bacteria via fluorescence-labeled antibodies within less than one hour. In detail, an air-sampling unit passes particles in the relevant size range to a substrate which contains antibodies with fluorescence labels for the detection of a specific microorganism. After the removal of the excess antibodies the optical detection unit comprising reflected-light and epifluorescence microscopy can identify the microorganisms by fast image processing on a single-particle level. First measurements with the system to identify various test particles as well as interfering influences have been performed, in particular with respect to autofluorescence of dust particles. Specific antibodies for the detection of Aspergillus fumigatus spores have been established. The biological test system consists of protein A-coated polymer particles which are detected by a fluorescence-labeled IgG. Furthermore the influence of interfering particles such as dust or debris is discussed.

  14. A Comparison of EPI Sampling, Probability Sampling, and Compact Segment Sampling Methods for Micro and Small Enterprises

    PubMed Central

    Chao, Li-Wei; Szrek, Helena; Peltzer, Karl; Ramlagan, Shandir; Fleming, Peter; Leite, Rui; Magerman, Jesswill; Ngwenya, Godfrey B.; Pereira, Nuno Sousa; Behrman, Jere

    2011-01-01

    Finding an efficient method for sampling micro- and small-enterprises (MSEs) for research and statistical reporting purposes is a challenge in developing countries, where registries of MSEs are often nonexistent or outdated. This lack of a sampling frame creates an obstacle in finding a representative sample of MSEs. This study uses computer simulations to draw samples from a census of businesses and non-businesses in the Tshwane Municipality of South Africa, using three different sampling methods: the traditional probability sampling method, the compact segment sampling method, and the World Health Organization’s Expanded Programme on Immunization (EPI) sampling method. Three mechanisms by which the methods could differ are tested, the proximity selection of respondents, the at-home selection of respondents, and the use of inaccurate probability weights. The results highlight the importance of revisits and accurate probability weights, but the lesser effect of proximity selection on the samples’ statistical properties. PMID:22582004

  15. A method for sampling waste corn

    USGS Publications Warehouse

    Frederick, R.B.; Klaas, E.E.; Baldassarre, G.A.; Reinecke, K.J.

    1984-01-01

    Corn had become one of the most important wildlife food in the United States. It is eaten by a wide variety of animals, including white-tailed deer (Odocoileus virginianus ), raccoon (Procyon lotor ), ring-necked pheasant (Phasianus colchicus , wild turkey (Meleagris gallopavo ), and many species of aquatic birds. Damage to unharvested crops had been documented, but many birds and mammals eat waste grain after harvest and do not conflict with agriculture. A good method for measuring waste-corn availability can be essential to studies concerning food density and food and feeding habits of field-feeding wildlife. Previous methods were developed primarily for approximating losses due to harvest machinery. In this paper, a method is described for estimating the amount of waste corn potentially available to wildlife. Detection of temporal changes in food availability and differences caused by agricultural operations (e.g., recently harvested stubble fields vs. plowed fields) are discussed.

  16. 78 FR 67360 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of Five New Equivalent Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-12

    ... March 6, 2009. The monitors are commercially available from the applicant, Thermo Fisher Scientific, Air... AGENCY Ambient Air Monitoring Reference and Equivalent Methods: Designation of Five New Equivalent... of the designation of five new equivalent methods for monitoring ambient air quality. SUMMARY:...

  17. Evaluation of Sampling Methods and Development of Sample Plans for Estimating Predator Densities in Cotton

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The cost-reliability of five sampling methods (visual search, drop cloth, beat bucket, shake bucket and sweep net) was determined for predatory arthropods on cotton plants. The beat bucket sample method was the most cost-reliable while the visual sample method was the least cost-reliable. The beat ...

  18. Modified electrokinetic sample injection method in chromatography and electrophoresis analysis

    DOEpatents

    Davidson, J. Courtney; Balch, Joseph W.

    2001-01-01

    A sample injection method for horizontal configured multiple chromatography or electrophoresis units, each containing a number of separation/analysis channels, that enables efficient introduction of analyte samples. This method for loading when taken in conjunction with horizontal microchannels allows much reduced sample volumes and a means of sample stacking to greatly reduce the concentration of the sample. This reduction in the amount of sample can lead to great cost savings in sample preparation, particularly in massively parallel applications such as DNA sequencing. The essence of this method is in preparation of the input of the separation channel, the physical sample introduction, and subsequent removal of excess material. By this method, sample volumes of 100 nanoliter to 2 microliters have been used successfully, compared to the typical 5 microliters of sample required by the prior separation/analysis method.

  19. Measurement of the resistivity of porous materials with an alternating air-flow method.

    PubMed

    Dragonetti, Raffaele; Ianniello, Carmine; Romano, Rosario A

    2011-02-01

    Air-flow resistivity is a main parameter governing the acoustic behavior of porous materials for sound absorption. The international standard ISO 9053 specifies two different methods to measure the air-flow resistivity, namely a steady-state air-flow method and an alternating air-flow method. The latter is realized by the measurement of the sound pressure at 2 Hz in a small rigid volume closed partially by the test sample. This cavity is excited with a known volume-velocity sound source implemented often with a motor-driven piston oscillating with prescribed area and displacement magnitude. Measurements at 2 Hz require special instrumentation and care. The authors suggest an alternating air-flow method based on the ratio of sound pressures measured at frequencies higher than 2 Hz inside two cavities coupled through a conventional loudspeaker. The basic method showed that the imaginary part of the sound pressure ratio is useful for the evaluation of the air-flow resistance. Criteria are discussed about the choice of a frequency range suitable to perform simplified calculations with respect to the basic method. These criteria depend on the sample thickness, its nonacoustic parameters, and the measurement apparatus as well. The proposed measurement method was tested successfully with various types of acoustic materials.

  20. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Marketing Service, Dairy Programs, or the Official Methods of Analysis of the Association of Official... 7 Agriculture 3 2011-01-01 2011-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable...

  1. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL, as issued by the USDA,...

  2. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL, as issued by the USDA,...

  3. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL as issued by the USDA, Agricultural...

  4. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL as issued by the USDA, Agricultural...

  5. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Representative Sampling Methods I...—Representative Sampling Methods The methods and equipment used for sampling waste materials will vary with the... Crushed or powdered material—ASTM Standard D346-75 Soil or rock-like material—ASTM Standard D420-69...

  6. Air Pollution Instrumentation: A Trend toward Physical Methods

    ERIC Educational Resources Information Center

    Maugh, Thomas H., II

    1972-01-01

    Reviews reasons for the trend from wet chemical'' analytic techniques for measuring air pollutants toward physical methods based upon chemiluminescence, electrochemical transduction, flame ionization coupled with gas chromotography, and spectroscopy. (AL)

  7. Microfluidic DNA sample preparation method and device

    DOEpatents

    Krulevitch, Peter A.; Miles, Robin R.; Wang, Xiao-Bo; Mariella, Raymond P.; Gascoyne, Peter R. C.; Balch, Joseph W.

    2002-01-01

    Manipulation of DNA molecules in solution has become an essential aspect of genetic analyses used for biomedical assays, the identification of hazardous bacterial agents, and in decoding the human genome. Currently, most of the steps involved in preparing a DNA sample for analysis are performed manually and are time, labor, and equipment intensive. These steps include extraction of the DNA from spores or cells, separation of the DNA from other particles and molecules in the solution (e.g. dust, smoke, cell/spore debris, and proteins), and separation of the DNA itself into strands of specific lengths. Dielectrophoresis (DEP), a phenomenon whereby polarizable particles move in response to a gradient in electric field, can be used to manipulate and separate DNA in an automated fashion, considerably reducing the time and expense involved in DNA analyses, as well as allowing for the miniaturization of DNA analysis instruments. These applications include direct transport of DNA, trapping of DNA to allow for its separation from other particles or molecules in the solution, and the separation of DNA into strands of varying lengths.

  8. Microbial counts and particulate matter levels in roadside air samples under skytrain stations, Bangkok, Thailand.

    PubMed

    Luksamijarulkul, Pipat; Kongtip, Pornpimol

    2010-05-01

    In conditions with heavy traffic and crowds of people on roadside areas under skytrain stations in Bangkok, the natural air ventilation may be insufficient and air quality may be poor. A study of 350 air samples collected from the roadside, under skytrain stations in Bangkok, was carried out to assess microbial counts (210 air samples) and particulate matter (PM10) levels (140 samples). The results reveal the mean +/- standard deviation bacterial counts and fungal counts were 406.8 +/- 302.7 cfu/m3 and 128.9 +/- 89.7 cfu/m3, respectively. The PM10 level was 186.1 +/- 188.1 microg/m3. When compared to recommended levels, 4.8% of air samples (10/210 samples) had bacterial counts more than recommended levels (> 1,000 cfu/ m3) and 27.1% (38/140 samples) had PM10 levels more than recommended levels (> 120 microg/m3). These may affect human health, especially of street venders who spend most of their working time in these areas. PMID:20578558

  9. Microbial counts and particulate matter levels in roadside air samples under skytrain stations, Bangkok, Thailand.

    PubMed

    Luksamijarulkul, Pipat; Kongtip, Pornpimol

    2010-05-01

    In conditions with heavy traffic and crowds of people on roadside areas under skytrain stations in Bangkok, the natural air ventilation may be insufficient and air quality may be poor. A study of 350 air samples collected from the roadside, under skytrain stations in Bangkok, was carried out to assess microbial counts (210 air samples) and particulate matter (PM10) levels (140 samples). The results reveal the mean +/- standard deviation bacterial counts and fungal counts were 406.8 +/- 302.7 cfu/m3 and 128.9 +/- 89.7 cfu/m3, respectively. The PM10 level was 186.1 +/- 188.1 microg/m3. When compared to recommended levels, 4.8% of air samples (10/210 samples) had bacterial counts more than recommended levels (> 1,000 cfu/ m3) and 27.1% (38/140 samples) had PM10 levels more than recommended levels (> 120 microg/m3). These may affect human health, especially of street venders who spend most of their working time in these areas.

  10. Joint air pollution sampling program in twin cities on the U.S.-Mexico border.

    PubMed

    Dávila, G H

    1976-01-01

    Ciudad Juárez (Chihuahua) and El Paso (Texas), two cities on the U.S.-Mexico border, form a single environmental system in which the same natural resources, especially air and water, are shared. It also constitutes a single metropolitan area which is characterized by high rates of pipulation growth, economic development, and urban expansion, all these factors mitigating against air quality. Early in 1972 the health authorities in El Paso and Ciudad Juárez initiated a joint air pollution sampling program with assistance from the Pan American Health Organization. The nearby city of Las Cruces (New Mexico) was later included in the program as well. Activities are carried out in accordance with a document entitled "Bases of Cooperation." The guiding criteria of the program are: functional simplicity, operational economy, and complementarity with other sampling programs conducted by the participating services. An Air Pollution Control Subcommittee is responsible for execution coordination of the program. Three studies are currently underway to determine levels of dust pollution in the air. A fourth study is aimed at measuring sulfur dioxide levels through the use of sulfation plates. The results collected reveal concentrations of particulates in the ambient air levels higher than the U.S. Federal primary standards. The program should be expanded to include the study of other pollutants and a joint inventory of emissions. In this way criteria on air quality may be established and joint plans of action and strategies drawn up for the control of air pollution in this important area.

  11. Method and Apparatus for Measuring Surface Air Pressure

    NASA Technical Reports Server (NTRS)

    Lin, Bing (Inventor); Hu, Yongxiang (Inventor)

    2014-01-01

    The present invention is directed to an apparatus and method for remotely measuring surface air pressure. In one embodiment, the method of the present invention utilizes the steps of transmitting a signal having multiple frequencies into the atmosphere, measuring the transmitted/reflected signal to determine the relative received power level of each frequency and then determining the surface air pressure based upon the attenuation of the transmitted frequencies.

  12. Report on sampling and analysis of ambient air at the central waste complex

    SciTech Connect

    Stauffer, M., Fluor Daniel Hanford

    1997-02-13

    Over 160 ambient indoor air samples were collected from warehouses at the Central Waste Complex used for the storage of low- level radioactive and mixed wastes. These grab (SUMMA) samples were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data from this survey suggest that several buildings had elevated concentrations of volatile organic compounds.

  13. EVALUATION OF THE FILTER PACK FOR LONG-DURATION SAMPLING OF AMBIENT AIR

    EPA Science Inventory

    A 14-week filter pack (FP) sampler evaluation field study was conducted at a site near Bondville, IL to investigate the impact of weekly sampling duration. Simultaneous samples were collected using collocated filter packs (FP) from two independent air quality monitoring networks...

  14. Development of a multicopter-carried whole air sampling apparatus and its applications in environmental studies.

    PubMed

    Chang, Chih-Chung; Wang, Jia-Lin; Chang, Chih-Yuan; Liang, Mao-Chang; Lin, Ming-Ren

    2016-02-01

    To advance the capabilities of probing chemical composition aloft, we designed a lightweight remote-controlled whole air sampling component (WASC) and integrated it into a multicopter drone with agile maneuverability to perform aerial whole air sampling. A field mission hovering over an exhaust shaft of a roadway tunnel to collect air samples was performed to demonstrate the applicability of the multicopter-carried WASC apparatus. Ten aerial air samples surrounding the shaft vent were collected by the multicopter-carried WASC. Additional five samples were collected manually inside the shaft for comparison. These samples were then analyzed in the laboratory for the chemical composition of 109 volatile organic compounds (VOCs), CH4, CO, CO2, or CO2 isotopologues. Most of the VOCs in the upwind samples (the least affected by shaft exhaust) were low in concentrations (5.9 ppbv for total 109 VOCs), posting a strong contrast to those in the shaft exhaust (235.8 ppbv for total 109 VOCs). By comparing the aerial samples with the in-shaft samples for chemical compositions, the influence of the shaft exhaust on the surrounding natural air was estimated. Through the aerial measurements, three major advantages of the multicopter-carried WASC were demonstrated: 1. The highly maneuverable multicopter-carried WASC can be readily deployed for three-dimensional environmental studies at a local scale (0-1.5 km); 2. Aerial sampling with superior sample integrity and preservation conditions can now be performed with ease; and 3. Data with spatial resolution for a large array of gaseous species with high precision can be easily obtained. PMID:26386435

  15. Development of a multicopter-carried whole air sampling apparatus and its applications in environmental studies.

    PubMed

    Chang, Chih-Chung; Wang, Jia-Lin; Chang, Chih-Yuan; Liang, Mao-Chang; Lin, Ming-Ren

    2016-02-01

    To advance the capabilities of probing chemical composition aloft, we designed a lightweight remote-controlled whole air sampling component (WASC) and integrated it into a multicopter drone with agile maneuverability to perform aerial whole air sampling. A field mission hovering over an exhaust shaft of a roadway tunnel to collect air samples was performed to demonstrate the applicability of the multicopter-carried WASC apparatus. Ten aerial air samples surrounding the shaft vent were collected by the multicopter-carried WASC. Additional five samples were collected manually inside the shaft for comparison. These samples were then analyzed in the laboratory for the chemical composition of 109 volatile organic compounds (VOCs), CH4, CO, CO2, or CO2 isotopologues. Most of the VOCs in the upwind samples (the least affected by shaft exhaust) were low in concentrations (5.9 ppbv for total 109 VOCs), posting a strong contrast to those in the shaft exhaust (235.8 ppbv for total 109 VOCs). By comparing the aerial samples with the in-shaft samples for chemical compositions, the influence of the shaft exhaust on the surrounding natural air was estimated. Through the aerial measurements, three major advantages of the multicopter-carried WASC were demonstrated: 1. The highly maneuverable multicopter-carried WASC can be readily deployed for three-dimensional environmental studies at a local scale (0-1.5 km); 2. Aerial sampling with superior sample integrity and preservation conditions can now be performed with ease; and 3. Data with spatial resolution for a large array of gaseous species with high precision can be easily obtained.

  16. IMPROVED TEST METHODS FOR ELECTRONIC AIR CLEANERS

    EPA Science Inventory

    The objective of this project was to develop a fractional filtration efficiency test protocol for residential electrostatic precipitators (ESPs) that avoids the limitations of the ASHRAE 52.2 method. Specifically, the objectives were to a) determine the change in efficiency that ...

  17. Methods for characterizing, classifying, and identifying unknowns in samples

    DOEpatents

    Grate, Jay W [West Richland, WA; Wise, Barry M [Manson, WA

    2002-01-01

    Disclosed is a method for taking the data generated from an array of responses from a multichannel instrument, and determining the characteristics of a chemical in the sample without the necessity of calibrating or training the instrument with known samples containing the same chemical. The characteristics determined by the method are then used to classify and identify the chemical in the sample. The method can also be used to quantify the concentration of the chemical in the sample.

  18. Methods for characterizing, classifying, and identifying unknowns in samples

    DOEpatents

    Grate, Jay W.; Wise, Barry M.

    2003-08-12

    Disclosed is a method for taking the data generated from an array of responses from a multichannel instrument, and determining the characteristics of a chemical in the sample without the necessity of calibrating or training the instrument with known samples containing the same chemical. The characteristics determined by the method are then used to classify and identify the chemical in the sample. The method can also be used to quantify the concentration of the chemical in the sample.

  19. Whole air canister sampling coupled with preconcentration GC/MS analysis of part-per-trillion levels of trimethylsilanol in semiconductor cleanroom air.

    PubMed

    Herrington, Jason S

    2013-08-20

    The costly damage airborne trimethylsilanol (TMS) exacts on optics in the semiconductor industry has resulted in the demand for accurate and reliable methods for measuring TMS at trace levels (i.e., parts per trillion, volume per volume of air [ppt(v)] [~ng/m(3)]). In this study I developed a whole air canister-based approach for field sampling trimethylsilanol in air, as well as a preconcentration gas chromatography/mass spectrometry laboratory method for analysis. The results demonstrate clean canister blanks (0.06 ppt(v) [0.24 ng/m(3)], which is below the detection limit), excellent linearity (a calibration relative response factor relative standard deviation [RSD] of 9.8%) over a wide dynamic mass range (1-100 ppt(v)), recovery/accuracy of 93%, a low selected ion monitoring method detection limit of 0.12 ppt(v) (0.48 ng/m(3)), replicate precision of 6.8% RSD, and stability (84% recovery) out to four days of storage at room temperature. Samples collected at two silicon wafer fabrication facilities ranged from 10.0 to 9120 ppt(v) TMS and appear to be associated with the use of hexamethyldisilazane priming agent. This method will enable semiconductor cleanroom managers to monitor and control for trace levels of trimethylsilanol.

  20. Technique for determination of accurate heat capacities of volatile, powdered, or air-sensitive samples using relaxation calorimetry

    NASA Astrophysics Data System (ADS)

    Marriott, Robert A.; Stancescu, Maria; Kennedy, Catherine A.; White, Mary Anne

    2006-09-01

    We introduce a four-step technique for the accurate determination of the heat capacity of volatile or air-sensitive samples using relaxation calorimetry. The samples are encapsulated in a hermetically sealed differential scanning calorimetry pan, in which there is an internal layer of Apiezon N grease to assist thermal relaxation. Using the Quantum Design physical property measurement system to investigate benzoic acid and copper standards, we find that this method can lead to heat capacity determinations accurate to ±2% over the temperature range of 1-300K, even for very small samples (e.g., <10mg and contributing ca. 20% to the total heat capacity).

  1. Comparison of mold concentrations quantified by MSQPCR in indoor and outdoor air sampled simultaneously

    SciTech Connect

    Meklin, Teija; Reponen, Tina; McKinstry, Craig A.; Cho, Seung H.; Grinshpun, Sergey A.; Nevalainen, Aino; Vepsalainen, Asko; Haugland, Richard A.; Lemasters, Grace; Vesper, Sephen J.

    2007-08-15

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of 36 mold species in dust and in indoor and in outdoor air samples that were taken simultaneously in 17 homes in Cincinnati with no-known water damage. The total spore concentrations in the indoor (I) and outdoor (O) air samples were statistically significantly different and the concentrations in the three sample types of many of the individual species were significantly different (p < 0.05 based on the Wilcoxon Signed Rank Test). The I/O ratios of the averages or geometric means of the individual species were generally less than 1; but these I/O ratios were quite variable ranging from 0.03 for A. sydowii to 1.2 for Acremonium strictum. There were no significant correlations for the 36 specific mold concentrations between the dust samples and the indoor or outdoor air samples (based on the Spearman’s Rho test). The indoor and outdoor air concentrations of 32 of the species were not correlated. Only Aspergillus penicillioides, C. cladosporioides types 1 and 2 and C. herbarum had sufficient data to estimate a correlation at rho > 0.5 with signicance (p < 0.05) In six of these homes, a previous dust sample had been collected and analyzed 2 years earlier. The ERMI© values for the dust samples taken in the same home two years apart were not significantly different (p=0.22) based on Wilcoxon Signed Rank Test.

  2. Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.; Pekour, Mikhail S.

    2014-12-02

    The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer

  3. Field sampling method for quantifying odorants in humid environments.

    PubMed

    Trabue, Steven L; Scoggin, Kenwood D; Li, Hong; Burns, Robert; Xin, Hongwei

    2008-05-15

    Most air quality studies in agricultural environments use thermal desorption analysis for quantifying semivolatile organic compounds (SVOCs) associated with odor. The objective of this study was to develop a robust sampling technique for measuring SVOCs in humid environments. Test atmospheres were generated at ambient temperatures (23 +/- 1.5 degrees C) and 25, 50, and 80% relative humidity (RH). Sorbent material used included Tenax, graphitized carbon, and carbon molecular sieve (CMS). Sorbent tubes were challenged with 2, 4, 8, 12, and 24 L of air at various RHs. Sorbent tubes with CMS material performed poorly at both 50 and 80% RH dueto excessive sorption of water. Heating of CMS tubes during sampling or dry-purging of CMS tubes post sampling effectively reduced water sorption with heating of tubes being preferred due to the higher recovery and reproducibility. Tenaxtubes had breakthrough of the more volatile compounds and tended to form artifacts with increasing volumes of air sampled. Graphitized carbon sorbent tubes containing Carbopack X and Carbopack C performed best with quantitative recovery of all compounds at all RHs and sampling volumes tested. The graphitized carbon tubes were taken to the field for further testing. Field samples taken from inside swine feeding operations showed that butanoic acid, 4-methylphenol, 4-ethylphenol, indole, and 3-methylindole were the compounds detected most often above their odor threshold values. Field samples taken from a poultry facility demonstrated that butanoic acid, 3-methylbutanoic acid, and 4-methylphenol were the compounds above their odor threshold values detected most often, relative humidity, CAFO, VOC, SVOC, thermal desorption, swine, poultry, air quality, odor. PMID:18546717

  4. Air sampling for hepatitis B surface antigen in a dental operatory.

    PubMed

    Petersen, N J; Bond, W W; Favero, M S

    1979-09-01

    Forty samples of air with a mean sample volume of 104 liters were collected during the treatment of patients whose blood was positive for HBsAG: no samples contained HBsAG and occult blood. These findings suggest that, if environmentally mediated transmission of hepatitis B occurs in the dental operatory, it is more likely to occur through contact with contaminated surfaces than through the airborne route.

  5. Sampling Methods in Cardiovascular Nursing Research: An Overview.

    PubMed

    Kandola, Damanpreet; Banner, Davina; O'Keefe-McCarthy, Sheila; Jassal, Debbie

    2014-01-01

    Cardiovascular nursing research covers a wide array of topics from health services to psychosocial patient experiences. The selection of specific participant samples is an important part of the research design and process. The sampling strategy employed is of utmost importance to ensure that a representative sample of participants is chosen. There are two main categories of sampling methods: probability and non-probability. Probability sampling is the random selection of elements from the population, where each element of the population has an equal and independent chance of being included in the sample. There are five main types of probability sampling including simple random sampling, systematic sampling, stratified sampling, cluster sampling, and multi-stage sampling. Non-probability sampling methods are those in which elements are chosen through non-random methods for inclusion into the research study and include convenience sampling, purposive sampling, and snowball sampling. Each approach offers distinct advantages and disadvantages and must be considered critically. In this research column, we provide an introduction to these key sampling techniques and draw on examples from the cardiovascular research. Understanding the differences in sampling techniques may aid nurses in effective appraisal of research literature and provide a reference pointfor nurses who engage in cardiovascular research.

  6. ELECTROSTATIC AIR CLEANING DEVICE AND METHOD

    DOEpatents

    Silverman, L.; Anderson, D.M.

    1961-07-18

    A method and apparatus for utilizing friction-charged particulate material from an aerosol are described. A bed of the plastic spheres is prepared, and the aerosol is passed upwardly through the bed at a rate just large enough to maintain the bed in a fluidized state wim over-all circulation of the balls. Wire members criss-crossing through the bed rub against the balls and maintain their surfaces with electrostatic charges. The particulate material in the aerosol adheres to the surfaces of the balls.

  7. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  8. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  9. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  10. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  11. 19 CFR 151.83 - Method of sampling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling....

  12. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  13. 19 CFR 151.83 - Method of sampling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 2 2014-04-01 2014-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling....

  14. 19 CFR 151.83 - Method of sampling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 2 2012-04-01 2012-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling....

  15. The contrast model method for the thermodynamical calculation of air-air wet heat exchanger

    NASA Astrophysics Data System (ADS)

    Yuan, Xiugan; Mei, Fang

    1989-02-01

    The 'contrast model' method thermodynamic calculation of air-air crossflow wet heat exchangers with initial air condensation is presented. Contrast-model equations are derived from the actual heat exchanger equations as well as imaginary ones; it is then possible to proceed to a proof that the enthalpy efficiency of the contrast model equations is similar to the temperature efficiency of the dry heat exchanger. Conditions are noted under which it becomes possible to unify thermodynamic calculations for wet and dry heat exchangers.

  16. A quantitative method for optimized placement of continuous air monitors.

    PubMed

    Whicker, Jeffrey J; Rodgers, John C; Moxley, John S

    2003-11-01

    Alarming continuous air monitors (CAMs) are a critical component for worker protection in facilities that handle large amounts of hazardous materials. In nuclear facilities, continuous air monitors alarm when levels of airborne radioactive materials exceed alarm thresholds, thus prompting workers to exit the room to reduce inhalation exposures. To maintain a high level of worker protection, continuous air monitors are required to detect radioactive aerosol clouds quickly and with good sensitivity. This requires that there are sufficient numbers of continuous air monitors in a room and that they are well positioned. Yet there are no published methodologies to quantitatively determine the optimal number and placement of continuous air monitors in a room. The goal of this study was to develop and test an approach to quantitatively determine optimal number and placement of continuous air monitors in a room. The method we have developed uses tracer aerosol releases (to simulate accidental releases) and the measurement of the temporal and spatial aspects of the dispersion of the tracer aerosol through the room. The aerosol dispersion data is then analyzed to optimize continuous air monitor utilization based on simulated worker exposure. This method was tested in a room within a Department of Energy operated plutonium facility at the Savannah River Site in South Carolina, U.S. Results from this study show that the value of quantitative airflow and aerosol dispersion studies is significant and that worker protection can be significantly improved while balancing the costs associated with CAM programs.

  17. Methods for determination of toxic organic compounds in air

    SciTech Connect

    Winberry, W.T. Jr.

    1990-01-01

    This paper provides environmental regulatory agencies, industry, and other interested parties with specific, standardized sampling and analysis procedures for toxic organic compounds in air. Compounds include Volatile Organic Compounds, Organochlorine Pesticides and PCBs, Aldehydes and Ketones, Phosgene, N-Nitrosodimethylamine, Phenol and Methylphenols (Cresols), Polychlorinated Dibenzo-p-Dioxins (PCDDs), Formaldehyde, Non-Methane Organic Compounds (NMOCs) and Polynuclear Aromatic Hydrocarbons (PAHs).

  18. Method to Estimate the Dissolved Air Content in Hydraulic Fluid

    NASA Technical Reports Server (NTRS)

    Hauser, Daniel M.

    2011-01-01

    In order to verify the air content in hydraulic fluid, an instrument was needed to measure the dissolved air content before the fluid was loaded into the system. The instrument also needed to measure the dissolved air content in situ and in real time during the de-aeration process. The current methods used to measure the dissolved air content require the fluid to be drawn from the hydraulic system, and additional offline laboratory processing time is involved. During laboratory processing, there is a potential for contamination to occur, especially when subsaturated fluid is to be analyzed. A new method measures the amount of dissolved air in hydraulic fluid through the use of a dissolved oxygen meter. The device measures the dissolved air content through an in situ, real-time process that requires no additional offline laboratory processing time. The method utilizes an instrument that measures the partial pressure of oxygen in the hydraulic fluid. By using a standardized calculation procedure that relates the oxygen partial pressure to the volume of dissolved air in solution, the dissolved air content is estimated. The technique employs luminescent quenching technology to determine the partial pressure of oxygen in the hydraulic fluid. An estimated Henry s law coefficient for oxygen and nitrogen in hydraulic fluid is calculated using a standard method to estimate the solubility of gases in lubricants. The amount of dissolved oxygen in the hydraulic fluid is estimated using the Henry s solubility coefficient and the measured partial pressure of oxygen in solution. The amount of dissolved nitrogen that is in solution is estimated by assuming that the ratio of dissolved nitrogen to dissolved oxygen is equal to the ratio of the gas solubility of nitrogen to oxygen at atmospheric pressure and temperature. The technique was performed at atmospheric pressure and room temperature. The technique could be theoretically carried out at higher pressures and elevated

  19. The impact of particle size selective sampling methods on occupational assessment of airborne beryllium particulates.

    PubMed

    Sleeth, Darrah K

    2013-05-01

    In 2010, the American Conference of Governmental Industrial Hygienists (ACGIH) formally changed its Threshold Limit Value (TLV) for beryllium from a 'total' particulate sample to an inhalable particulate sample. This change may have important implications for workplace air sampling of beryllium. A history of particle size-selective sampling methods, with a special focus on beryllium, will be provided. The current state of the science on inhalable sampling will also be presented, including a look to the future at what new methods or technology may be on the horizon. This includes new sampling criteria focused on particle deposition in the lung, proposed changes to the existing inhalable convention, as well as how the issues facing beryllium sampling may help drive other changes in sampling technology.

  20. Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1974-01-01

    The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

  1. Evaluation of a portable X-ray fluorescence instrument for the determination of lead in workplace air samples.

    PubMed

    Morley, J C; Clark, C S; Deddens, J A; Ashley, K; Roda, S

    1999-05-01

    Occupational Safety and Health Administration (OSHA) regulations for worker exposure to lead specify worker protection levels based upon airborne concentrations of lead dust. The rapid, on-site determination of lead in air filter samples using a portable x-ray fluorescence (XRF) instrument with an attachment to hold the filter would expedite the exposure assessment process and facilitate compliance with the OSHA standards. A total of 65 lead in air filter samples were collected at bridge blasting lead-abatement projects using closed-faced, 37-mm cassettes with pre-loaded 0.8 micron pore size mixed cellulose ester membrane filters. The lead loading range of the data set was 0.1-1514.6 micrograms (micrograms) of lead/sample. Samples were initially analyzed with a field portable XRF (NITON 700) using an experimental non-destructive XRF method. Samples were subsequently analyzed using National Institute for Occupational Safety and Health (NIOSH) Method 7105 (Graphite Furnace AA) as a reference analytical method. The paired data were not normally distributed; therefore, the non-parametric Wilcoxon signed rank test was used for statistical analysis. There was no statistically significant difference between data from the field portable XRF method and the NIOSH method (p-value = 0.72). Linear regression of the data resulted in a slope of 0.959, a y-intercept of 5.20 micrograms, and an r2 of 0.985. The XRF limit of detection and limit of quantitation were determined to be 6.2 and 17 micrograms of lead/sample, respectively. The XRF method accuracy was +/- 16.4% (7.1%-27%, 90% confidence interval). The data presented in this study indicate that field-portable XRF can be used for the analysis of lead air filter samples over the range of 17 to 1500 micrograms of lead/sample. The practicing industrial hygienist can use field-portable XRF to produce a rapid, on-site determination of lead exposure that can immediately be communicated to workers and help identify appropriate levels

  2. Photoacoustic sample vessel and method of elevated pressure operation

    DOEpatents

    Autrey, Tom; Yonker, Clement R.

    2004-05-04

    An improved photoacoustic vessel and method of photoacoustic analysis. The photoacoustic sample vessel comprises an acoustic detector, an acoustic couplant, and an acoustic coupler having a chamber for holding the acoustic couplant and a sample. The acoustic couplant is selected from the group consisting of liquid, solid, and combinations thereof. Passing electromagnetic energy through the sample generates an acoustic signal within the sample, whereby the acoustic signal propagates through the sample to and through the acoustic couplant to the acoustic detector.

  3. Detection of airborne bacteria in a duck production facility with two different personal air sampling devices for an exposure assessment.

    PubMed

    Martin, Elena; Dziurowitz, Nico; Jäckel, Udo; Schäfer, Jenny

    2015-01-01

    Prevalent airborne microorganisms are not well characterized in industrial animal production buildings with respect to their quantity or quality. To investigate the work-related microbial exposure, personal bioaerosol sampling during the whole working day is recommended. Therefore, bioaerosol sampling in a duck hatchery and a duck house with two personal air sampling devices, a filter-based PGP and a NIOSH particle size separator, was performed. Subsequent, quantitative and qualitative analyses were carried out with" culture independent methods. Total cell concentrations (TCC) determined via fluorescence microscopy showed no difference between the two devices. In average, 8 × 10(6) cells/m(3) were determined in the air of the duck hatchery and 5 × 10(7) cells/m(3) in the air of the duck house. A Generated Restriction Fragment Length Polymorphism (RFLP) pattern revealed deviant bacterial compositions comparing samples collected with both devices. Clone library analyses based on 16S rRNA gene sequence analysis from the hatchery's air showed 65% similarity between the two sampling devices. Detailed 16S rRNA gene sequence analyses showed the occurrence of bacterial species like Acinetobacter baumannii, Enterococcus faecalis, Escherichia sp., and Shigella sp.; and a group of Staphylococcus delphini, S. intermedius, and S. pseudintermedius that provided the evidence of potential exposure to risk group 2 bacteria at the hatchery workplace. Size fractionated sampling with the developed by the Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA) device revealed that pathogenic bacteria would deposit in the inhalable, the thorax, and possibly alveolar dust fraction according to EN481. TCC analysis showed the deposition of bacterial cells in the third stage (< 1μm) at the NIOSH device which implies that bacteria can reach deep into the lungs and contaminate the alveolus after inhalation. Nevertheless, both personal sampling devices

  4. Detection of Mycoplasma hyopneumoniae by Air Sampling with a Nested PCR Assay

    PubMed Central

    Stärk, Katharina D. C.; Nicolet, Jacques; Frey, Joachim

    1998-01-01

    This article describes the first successful detection of airborne Mycoplasma hyopneumoniae under experimental and field conditions with a new nested PCR assay. Air was sampled with polyethersulfone membranes (pore size, 0.2 μm) mounted in filter holders. Filters were processed by dissolution and direct extraction of DNA for PCR analysis. For the PCR, two nested pairs of oligonucleotide primers were designed by using an M. hyopneumoniae-specific DNA sequence of a repeated gene segment. A nested PCR assay was developed and used to analyze samples collected in eight pig houses where respiratory problems had been common. Air was also sampled from a mycoplasma-free herd. The nested PCR was highly specific and 104 times as sensitive as a one-step PCR. Under field conditions, the sampling system was able to detect airborne M. hyopneumoniae on 80% of farms where acute respiratory disease was present. No airborne M. hyopneumoniae was detected on infected farms without acute cases. The chance of successful detection was increased if air was sampled at several locations within a room and at a lower air humidity. PMID:9464391

  5. Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

    NASA Technical Reports Server (NTRS)

    Condon, E. P.; Vedder, J. F.

    1984-01-01

    Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

  6. Isolation of airborne oxacillin-resistant Staphylococcus aureus from culturable air samples of urban residences.

    PubMed

    Perez, Hernando R; Johnson, Rachel; Gurian, Patrick L; Gibbs, Shawn G; Taylor, Jennifer; Burstyn, Igor

    2011-02-01

    Culturable single-stage impactor samples were collected onto nutrient agar in kitchen and bedroom areas of eight urban and four suburban residences in Philadelphia, Pennsylvania. Staphylococcus aureus colonies were identified by replica plating of the original impactor samples onto Chapman Stone medium followed by isolation of up to eight colonies for coagulase testing. Kirby-Bauer disk diffusion method was utilized to evaluate S. aureus resistance to both oxacillin and cefaclor. The median concentrations of total culturable bacteria observed in bedrooms and trash areas were 300 CFU/m(3) and 253 CFU/m(3), respectively. Median culturable Staphylococcus spp. concentrations in bedrooms and trash areas were 142 CFU/m(3) and 204 CFU/m(3), respectively. A total of 148 individual S. aureus colonies were isolated and tested for antibiotic resistance. Cefaclor resistance was encountered among only 6 of the 148 (4%) colonies. Nearly one-quarter of all S. aureus isolates tested displayed resistance (n = 30) or intermediate resistance (n = 5) to oxacillin. Twenty-six percent (n = 20) of trash area isolates and 21% (n = 15) of bedroom isolates displayed resistance or intermediate resistance to oxacillin. The median difference in percent resistance between trash and bedroom areas was 10% (p = 0.1). Results suggest that there may be a systematic difference in bacterial populations between downtown and suburban residences. Storage of household waste and handling of food may contribute to presence of the organism in the air of residences.

  7. Systems and methods for self-synchronized digital sampling

    NASA Technical Reports Server (NTRS)

    Samson, Jr., John R. (Inventor)

    2008-01-01

    Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

  8. A method for selecting training samples based on camera response

    NASA Astrophysics Data System (ADS)

    Zhang, Leihong; Li, Bei; Pan, Zilan; Liang, Dong; Kang, Yi; Zhang, Dawei; Ma, Xiuhua

    2016-09-01

    In the process of spectral reflectance reconstruction, sample selection plays an important role in the accuracy of the constructed model and in reconstruction effects. In this paper, a method for training sample selection based on camera response is proposed. It has been proved that the camera response value has a close correlation with the spectral reflectance. Consequently, in this paper we adopt the technique of drawing a sphere in camera response value space to select the training samples which have a higher correlation with the test samples. In addition, the Wiener estimation method is used to reconstruct the spectral reflectance. Finally, we find that the method of sample selection based on camera response value has the smallest color difference and root mean square error after reconstruction compared to the method using the full set of Munsell color charts, the Mohammadi training sample selection method, and the stratified sampling method. Moreover, the goodness of fit coefficient of this method is also the highest among the four sample selection methods. Taking all the factors mentioned above into consideration, the method of training sample selection based on camera response value enhances the reconstruction accuracy from both the colorimetric and spectral perspectives.

  9. Evidence for microorganisms in stratosphere air samples collected at a height of 41km

    NASA Astrophysics Data System (ADS)

    Wainwright, Milton; Wickramasinghe, Nalin C.; Narlikar, J. V.; Rajaratnam, P.

    2003-02-01

    Samples of air removed from the stratosphere, at an altitude of 41km, were previously found to contain viable, but non-cultureable bacteria (cocci and rods). Here, we describe experiments aimed at growing these organisms, together with any others, present in the samples. Two bacteria (Bacillus simplex and Staphylococcus pasteuri) and a single fungus, Engyodontium albus (limber)de Hoog were isolated from the samples. Contamination can never be ruled out when space-derived samples are studied on earth, however, we are confident that the organisms isolated here originated from the stratosphere.

  10. A comparison of four gravimetric fine particle sampling methods.

    PubMed

    Yanosky, J D; MacIntosh, D L

    2001-06-01

    A study was conducted to compare four gravimetric methods of measuring fine particle (PM2.5) concentrations in air: the BGI, Inc. PQ200 Federal Reference Method PM2.5 (FRM) sampler; the Harvard-Marple Impactor (HI); the BGI, Inc. GK2.05 KTL Respirable/Thoracic Cyclone (KTL); and the AirMetrics MiniVol (MiniVol). Pairs of FRM, HI, and KTL samplers and one MiniVol sampler were collocated and 24-hr integrated PM2.5 samples were collected on 21 days from January 6 through April 9, 2000. The mean and standard deviation of PM2.5 levels from the FRM samplers were 13.6 and 6.8 microg/m3, respectively. Significant systematic bias was found between mean concentrations from the FRM and the MiniVol (1.14 microg/m3, p = 0.0007), the HI and the MiniVol (0.85 microg/m3, p = 0.0048), and the KTL and the MiniVol (1.23 microg/m3, p = 0.0078) according to paired t test analyses. Linear regression on all pairwise combinations of the sampler types was used to evaluate measurements made by the samplers. None of the regression intercepts was significantly different from 0, and only two of the regression slopes were significantly different from 1, that for the FRM and the MiniVol [beta1 = 0.91, 95% CI (0.83-0.99)] and that for the KTL and the MiniVol [beta1 = 0.88, 95% CI (0.78-0.98)]. Regression R2 terms were 0.96 or greater between all pairs of samplers, and regression root mean square error terms (RMSE) were 1.65 microg/m3 or less. These results suggest that the MiniVol will underestimate measurements made by the FRM, the HI, and the KTL by an amount proportional to PM2.5 concentration. Nonetheless, these results indicate that all of the sampler types are comparable if approximately 10% variation on the mean levels and on individual measurement levels is considered acceptable and the actual concentration is within the range of this study (5-35 microg/m3).

  11. A method for near real time continuous air monitoring of phosgene, hydrogen cyanide, and cyanogen chloride

    SciTech Connect

    Lattin, F.G.; Paul, D.G.

    1996-12-31

    A sorbent-based gas chromatographic method provides continuous quantitative measurement of phosgene, hydrogen cyanide, and cyanogen chloride in ambient air. These compounds are subject to workplace exposure limits as well as regulation under terms of the Chemical Arms Treaty and Title III of the 1990 Clean Air Act amendments. The method was developed for on-site use in a mobile laboratory during remediation operations. Incorporated into the method are automated multi-level calibrations at time weighted average (TW) concentrations, or lower. Gaseous standards are prepared in fused silica lined air sampling canisters, then transferred to the analytical system through dynamic spiking. Precision and accuracy studies performed to validate the method are described. Also described are system deactivation and passivation techniques critical to optimum method performance.

  12. Professional judgment and the interpretation of viable mold air sampling data.

    PubMed

    Johnson, David; Thompson, David; Clinkenbeard, Rodney; Redus, Jason

    2008-10-01

    Although mold air sampling is technically straightforward, interpreting the results to decide if there is an indoor source is not. Applying formal statistical tests to mold sampling data is an error-prone practice due to the extreme data variability. With neither established exposure limits nor useful statistical techniques, indoor air quality investigators often must rely on their professional judgment, but the lack of a consensus "decision strategy" incorporating explicit decision criteria requires professionals to establish their own personal set of criteria when interpreting air sampling data. This study examined the level of agreement among indoor air quality practitioners in their evaluation of airborne mold sampling data and explored differences in inter-evaluator assessments. Eighteen investigators independently judged 30 sets of viable mold air sampling results to indicate: "definite indoor mold source," "likely indoor mold source," "not enough information to decide," "likely no indoor mold source," or "definitely no indoor mold source." Kappa coefficient analysis indicated weak inter-observer reliability, and comparison of evaluator mean scores showed clear inter-evaluator differences in their overall scoring patterns. The responses were modeled on indicator "traits" of the data sets using a generalized, linear mixed model approach and showed several traits to be associated with respondents' ratings, but they also demonstrated distinct and divergent inter-evaluator response patterns. Conclusions were that there was only weak overall agreement in evaluation of the mold sampling data, that particular traits of the data were associated with the conclusions reached, and that there were substantial inter-evaluator differences that were likely due to differences in the personal decision criteria employed by the individual evaluators. The overall conclusion was that there is a need for additional work to rigorously explore the constellation of decision criteria

  13. Sampling bee communities using pan traps: alternative methods increase sample size

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Monitoring of the status of bee populations and inventories of bee faunas require systematic sampling. Efficiency and ease of implementation has encouraged the use of pan traps to sample bees. Efforts to find an optimal standardized sampling method for pan traps have focused on pan trap color. Th...

  14. A charcoal sampling method and a gas chromatographic analytical procedure for carbon disulfide.

    PubMed

    McCammon, C S; Quinn, P M; Kupel, R E

    1975-08-01

    Research is reported concerning an acceptable method for sampling and analyzing samples for carbon disulfide. Test atmospheres of carbon disulfide were generated dynamically using the syringe injection method, ant the theoretical concetnration verified by a liquid absorbent, colorimetric method. The CS2 was adsorbed on charcoal tubes, eluted with benzene, and quantitated with a gas chromatography equipped with a sulfer flame photometric detector. The results compared with the colorimetris analysis. The sensitivity of this method is 1 mug on a charcoal tube. The charcoal tubes were also tested for breakthrough volumes, holding power vs time, and the effect of air transport and temperature cycles.

  15. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    SciTech Connect

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES

  16. Development and calibration of real-time PCR for quantification of airborne microorganisms in air samples

    NASA Astrophysics Data System (ADS)

    An, Hey Reoun; Mainelis, Gediminas; White, Lori

    This manuscript describes the coupling of bioaerosol collection and the use of real-time PCR (RT-PCR) to quantify the airborne bacteria. The quantity of collected bacteria determined by RT-PCR is compared with conventional quantification techniques, such as culturing, microscopy and airborne microorganism counting by using optical particle counter (OPC). Our data show that an experimental approach used to develop standard curves for use with RT-PCR is critical for accurate sample quantification. Using universal primers we generated 12 different standard curves which were used to quantify model organism Escherichia coli (Migula) Catellani from air samples. Standard curves prepared using a traditional approach, where serially diluted genomic DNA extracted from pure cultured bacteria were used in PCR reaction as a template DNA yielded significant underestimation of sample quantities compared to airborne microorganism concentration as measured by an OPC. The underestimation was especially pronounced when standard curves were built using colony forming units (CFUs). In contrast, the estimate of cell concentration in an air sample by RT-PCR was more accurate (˜60% compared to the airborne microorganism concentration) when the standard curve was built using aerosolized E. coli. The accuracy improved even further (˜100%) when air samples used to build the standard curves were diluted first, then the DNA extracted from each dilution was amplified by the RT-PCR—to mimic the handling of air samples with unknown and possibly low concentration. Therefore, our data show that standard curves used for quantification by RT-PCR needs to be prepared using the same environmental matrix and procedures as handling of the environmental sample in question. Reliance on the standard curves generated with cultured bacterial suspension (a traditional approach) may lead to substantial underestimation of microorganism quantities in environmental samples.

  17. A RAPID DNA EXTRACTION METHOD FOR PCR IDENTIFICATION OF FUNGAL INDOOR AIR CONTAMINANTS

    EPA Science Inventory

    Following air sampling, fungal DNA needs to be extracted and purified to a state suitable for laboratory use. Our laboratory has developed a simple method of extraction and purification of fungal DNA appropriate for enzymatic manipulation and polymerase chain reaction (PCR) appli...

  18. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    PubMed

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis. PMID:26525264

  19. Permeation of atmospheric gases through polymer O-rings used in flasks for air sampling

    NASA Astrophysics Data System (ADS)

    Sturm, P.; Leuenberger, M.; Sirignano, C.; Neubert, R. E. M.; Meijer, H. A. J.; Langenfelds, R.; Brand, W. A.; Tohjima, Y.

    2004-02-01

    Permeation of various gases through elastomeric O-ring seals can have important effects on the integrity of atmospheric air samples collected in flasks and measured some time later. Depending on the materials and geometry of flasks and valves and on partial pressure differences between sample and surrounding air, the concentrations of different components of air can be significantly altered during storage. The influence of permeation is discussed for O2/N2, Ar/N2, CO2, δ13C in CO2, and water vapor. Results of sample storage tests for various flask and valve types and different storage conditions are presented and are compared with theoretical calculations. Effects of permeation can be reduced by maintaining short storage times and small partial pressure differences and by using a new valve design that buffers exchange of gases with surrounding air or by using less permeable materials (such as Kel-F) as sealing material. General awareness of possible permeation effects helps to achieve more reliable measurements of atmospheric composition with flask sampling techniques.

  20. Air and smear sample calculational tool for Fluor Hanford Radiological control

    SciTech Connect

    BAUMANN, B.L.

    2003-09-24

    A spreadsheet calculation tool was developed to automate the calculations performed for determining the concentration of airborne radioactivity and smear counting as outlined in HNF-13536, Section 5.2.7, Analyzing Air and smear Samples. This document reports on the design and testing of the calculation tool.

  1. Development of a wireless air pollution sensor package for aerial-sampling of emissions

    EPA Science Inventory

    A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particulate matter wi...

  2. Modeling and Qualification of a Modified Emission Unit for Radioactive Air Emissions Stack Sampling Compliance.

    PubMed

    Barnett, J Matthew; Yu, Xiao-Ying; Recknagle, Kurtis P; Glissmeyer, John A

    2016-11-01

    A planned laboratory space and exhaust system modification to the Pacific Northwest National Laboratory Material Science and Technology Building indicated that a new evaluation of the mixing at the air sampling system location would be required for compliance to ANSI/HPS N13.1-2011. The modified exhaust system would add a third fan, thereby increasing the overall exhaust rate out the stack, thus voiding the previous mixing study. Prior to modifying the radioactive air emissions exhaust system, a three-dimensional computational fluid dynamics computer model was used to evaluate the mixing at the sampling system location. Modeling of the original three-fan system indicated that not all mixing criteria could be met. A second modeling effort was conducted with the addition of an air blender downstream of the confluence of the three fans, which then showed satisfactory mixing results. The final installation included an air blender, and the exhaust system underwent full-scale tests to verify velocity, cyclonic flow, gas, and particulate uniformity. The modeling results and those of the full-scale tests show agreement between each of the evaluated criteria. The use of a computational fluid dynamics code was an effective aid in the design process and allowed the sampling system to remain in its original location while still meeting the requirements for sampling at a well mixed location. PMID:27682902

  3. COMPARISON OF MOLD CONCENTRATIONS IN INDOOR AND OUTDOOR AIR SAMPLED SIMULTANEOUSLY AND THEN QUANTIFIED BY MSQPCR

    EPA Science Inventory

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 hours in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m3...

  4. Methods for sampling and inorganic analysis of coal

    USGS Publications Warehouse

    Golightly, D. W.; Simon, Frederick Otto

    1989-01-01

    Methods used by the U.S. Geological Survey for the sampling, comminution, and inorganic analysis of coal are summarized in this bulletin. Details, capabilities, and limitations of the methods are presented.

  5. DOE methods for evaluating environmental and waste management samples.

    SciTech Connect

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  6. A spatial multicriteria model for determining air pollution at sample locations.

    PubMed

    Réquia Júnior, Weeberb João; Roig, Henrique Llacer; Koutrakis, Petros

    2015-02-01

    Atmospheric pollution in urban centers has been one of the main causes of human illness related to the respiratory and circulatory system. Efficient monitoring of air quality is a source of information for environmental management and public health. This study investigates the spatial patterns of atmospheric pollution using a spatial multicriteria model that helps target locations for air pollution monitoring sites. The main objective was to identify high-priority areas for measuring human exposures to air pollutants as they relate to emission sources. The method proved to be viable and flexible in its application to various areas.

  7. Method for preconcentrating a sample for subsequent analysis

    DOEpatents

    Zaromb, Solomon

    1990-01-01

    A system for analysis of trace concentration of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  8. Analytical instrument with apparatus and method for sample concentrating

    DOEpatents

    Zaromb, S.

    1986-08-04

    A system for analysis of trace concentrations of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  9. In-depth analysis of sampling optimization methods

    NASA Astrophysics Data System (ADS)

    Lee, Honggoo; Han, Sangjun; Kim, Myoungsoo; Habets, Boris; Buhl, Stefan; Guhlemann, Steffen; Rößiger, Martin; Bellmann, Enrico; Kim, Seop

    2016-03-01

    High order overlay and alignment models require good coverage of overlay or alignment marks on the wafer. But dense sampling plans are not possible for throughput reasons. Therefore, sampling plan optimization has become a key issue. We analyze the different methods for sampling optimization and discuss the different knobs to fine-tune the methods to constraints of high volume manufacturing. We propose a method to judge sampling plan quality with respect to overlay performance, run-to-run stability and dispositioning criteria using a number of use cases from the most advanced lithography processes.

  10. Method and apparatus for imaging a sample on a device

    DOEpatents

    Trulson, Mark; Stern, David; Fiekowsky, Peter; Rava, Richard; Walton, Ian; Fodor, Stephen P. A.

    2001-01-01

    A method and apparatus for imaging a sample are provided. An electromagnetic radiation source generates excitation radiation which is sized by excitation optics to a line. The line is directed at a sample resting on a support and excites a plurality of regions on the sample. Collection optics collect response radiation reflected from the sample I and image the reflected radiation. A detector senses the reflected radiation and is positioned to permit discrimination between radiation reflected from a certain focal plane in the sample and certain other planes within the sample.

  11. Rapid method for sampling metals for materials identification

    NASA Technical Reports Server (NTRS)

    Higgins, L. E.

    1971-01-01

    Nondamaging process similar to electrochemical machining is useful in obtaining metal samples from places inaccessible to conventional sampling methods or where methods would be hazardous or contaminating to specimens. Process applies to industries where metals or metal alloys play a vital role.

  12. Engineering Study of 500 ML Sample Bottle Transportation Methods

    SciTech Connect

    BOGER, R.M.

    1999-08-25

    This engineering study reviews and evaluates all available methods for transportation of 500-mL grab sample bottles, reviews and evaluates transportation requirements and schedules and analyzes and recommends the most cost-effective method for transporting 500-mL grab sample bottles.

  13. GROUND WATER PURGING AND SAMPLING METHODS: HISTORY VS. HYSTERIA

    EPA Science Inventory

    It has been over 10 years since the low-flow ground water purging and sampling method was initially reported in the literature. The method grew from the recognition that well purging was necessary to collect representative samples, bailers could not achieve well purging, and high...

  14. A method and fortran program for quantitative sampling in paleontology

    USGS Publications Warehouse

    Tipper, J.C.

    1976-01-01

    The Unit Sampling Method is a binomial sampling method applicable to the study of fauna preserved in rocks too well cemented to be disaggregated. Preliminary estimates of the probability of detecting each group in a single sampling unit can be converted to estimates of the group's volumetric abundance by means of correction curves obtained by a computer simulation technique. This paper describes the technique and gives the FORTRAN program. ?? 1976.

  15. Human breath analysis: methods for sample collection and reduction of localized background effects.

    PubMed

    Martin, Audrey N; Farquar, George R; Jones, A Daniel; Frank, Matthias

    2010-01-01

    Solid-phase microextraction (SPME) was applied, in conjunction with gas chromatography-mass spectrometry, to the analysis of volatile organic compounds (VOCs) in human breath samples without requiring exhaled breath condensate collection. A new procedure, exhaled breath vapor (EBV) collection, involving the active sampling and preconcentration of a breath sample with a SPME fiber fitted inside a modified commercial breath-collection device, the RTube, is described. Immediately after sample collection, compounds are desorbed from the SPME fiber at 250 degrees C in the GC-MS injector. Experiments were performed using EBV collected at -80 degrees C and at room temperature, and the results compared to the traditional method of collecting exhaled breath condensate at -80 degrees C followed by passive SPME sampling of the collected condensate. Methods are compared in terms of portability, ease-of-use, speed of analysis, and detection limits. The need for a clean air supply for the study subjects is demonstrated using several localized sources of VOC contaminants including nail polish, lemonade, and gasoline. Various simple methods to supply clean inhaled air to a subject are presented. Chemical exposures are used to demonstrate the importance of providing cleaned air (organic vapor respirator) or an external air source (tubing stretched to a separate room). These techniques allow for facile data interpretation by minimizing background contaminants. It is demonstrated herein that this active SPME breath-sampling device provides advantages in the forms of faster sample collection and data analysis, apparatus portability and avoidance of power or cooling requirements, and performance for sample collection in a contaminated environment. PMID:19844696

  16. Alternative Methods for Assessing Contaminant Transport from the Vadose Zone to Indoor Air

    NASA Astrophysics Data System (ADS)

    Baylor, K. J.; Lee, A.; Reddy, P.; Plate, M.

    2010-12-01

    Vapor intrusion, which is the transport of contaminant vapors from groundwater and the vadose zone to indoor air, has emerged as a significant human health risk near hazardous waste sites. Volatile organic compounds (VOCs) such as trichloroethylene (TCE) and tetrachloroethylene (PCE) can volatilize from groundwater and from residual sources in the vadose zone and enter homes and commercial buildings through cracks in the slab, plumbing conduits, or other preferential pathways. Assessment of the vapor intrusion pathway typically requires collection of groundwater, soil gas, and indoor air samples, a process which can be expensive and time-consuming. We evaluated three alternative vapor intrusion assessment methods, including 1) use of radon as a surrogate for vapor intrusion, 2) use of pressure differential measurements between indoor/outdoor and indoor/subslab to assess the potential for vapor intrusion, and 3) use of passive, longer-duration sorbent methods to measure indoor air VOC concentrations. The primary test site, located approximately 30 miles south of San Francisco, was selected due to the presence of TCE (10 - 300 ug/L) in shallow groundwater (5 to 10 feet bgs). At this test site, we found that radon was not a suitable surrogate to asses vapor intrusion and that pressure differential measurements are challenging to implement and equipment-intensive. More significantly, we found that the passive, longer-duration sorbent methods are easy to deploy and compared well quantitatively with standard indoor air sampling methods. The sorbent technique is less than half the cost of typical indoor air methods, and also provides a longer duration sample, typically 3 to 14 days rather than 8 to 24 hours for standard methods. The passive sorbent methods can be a reliable, cost-effective, and easy way to sample for TCE, PCE and other VOCs as part of a vapor intrusion investigation.

  17. Determination of trichloroanisole and trichlorophenol in wineries' ambient air by passive sampling and thermal desorption-gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Camino-Sánchez, F J; Bermúdez-Peinado, R; Zafra-Gómez, A; Ruíz-García, J; Vílchez-Quero, J L

    2015-02-01

    The present paper describes the calibration of selected passive samplers used in the quantitation of trichlorophenol and trichloroanisole in wineries' ambient air, by calculating the corresponding sampling rates. The method is based on passive sampling with sorbent tubes and involves thermal desorption-gas chromatography-triple quadrupole mass spectrometry analysis. Three commercially available sorbents were tested using sampling cartridges with a radial design instead of axial ones. The best results were found for Tenax TA™. Sampling rates (R-values) for the selected sorbents were determined. Passive sampling was also used for accurately determining the amount of compounds present in the air. Adequate correlation coefficients between the mass of the target analytes and exposure time were obtained. The proposed validated method is a useful tool for the early detection of trichloroanisole and its precursor trichlorophenol in wineries' ambient air while avoiding contamination of wine or winery facilities.

  18. Analysis of polychlorinated biphenyls in concurrently sampled Chinese air and surface soil.

    PubMed

    Zhang, Zhi; Liu, Liyan; Li, Yi-Fan; Wang, Degao; Jia, Hongliang; Harner, Tom; Sverko, Ed; Wan, Xinnan; Xu, Diandou; Ren, Nanqi; Ma, Jianmin; Pozo, Karla

    2008-09-01

    Polychlorinated biphenyl (PCB) concentrations were measured in a concurrent air and surface soil sampling program across China. Passive air samples were collected for approximately 3 months from mid-July to mid-October, 2005 using polyurethane foam (PUF) disk type samplers at 97 sites and surface soil samples were collected in a subset of 51 sites in the same year. As expected, the air concentrations (pg m(-3)) were highest at urban sites (mean of 350 +/- 218) followed by rural (230 +/- 180) and background sites (77 +/- 50). The PCB homologue composition was similar across China, with no distinction among site types, and reflected the profile of Chinese transformer oil with a greater proportion of lower molecular weight (LMW) congeners, particularly the tri-PCBs. This differs from the profile in Chinese soil that was shifted toward the higher molecular weight (HMW) congeners and likely attributed to numerous years of deposition and accumulation in this reservoir. The PCB profile in surface soil also reflects an "urban fractionation effect" with preferential deposition of HMW congeners near sources. The profile of PCBs in Chinese air was shown to be different than reported for Europe and for the Great Lakes Area (GLA) in North America. European and GLA air samples show a distinction between urban and rural/V background sites, with urban sites dominated by tetra- and penta-PCBs, whereas rural and background sites are shifted toward LMW congeners. European and GLA samples also exhibit much higher PCB concentrations at urban sites. This may be attributed to the use of PCBs in building materials in European and North American cities. In China, the difference between urban and rural/background sites is less pronounced. Strong soil-air correlations were found for the LMW PCBs at the background and rural sites, and for the HMW PCBs at the urban sites, a strong evidence of the urban fractionation effect. To our knowledge, this is the first national-scale study in China

  19. A Mixed Methods Sampling Methodology for a Multisite Case Study

    ERIC Educational Resources Information Center

    Sharp, Julia L.; Mobley, Catherine; Hammond, Cathy; Withington, Cairen; Drew, Sam; Stringfield, Sam; Stipanovic, Natalie

    2012-01-01

    The flexibility of mixed methods research strategies makes such approaches especially suitable for multisite case studies. Yet the utilization of mixed methods to select sites for these studies is rarely reported. The authors describe their pragmatic mixed methods approach to select a sample for their multisite mixed methods case study of a…

  20. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    SciTech Connect

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  1. Chemical reactivities of ambient air samples in three Southern California communities

    PubMed Central

    Eiguren-Fernandez, Arantza; Di Stefano, Emma; Schmitz, Debra A.; Guarieiro, Aline Lefol Nani; Salinas, Erika M.; Nasser, Elina; Froines, John R.; Cho, Arthur K.

    2015-01-01

    The potential adverse health effects of PM2.5 and vapor samples from three communities that neighbor railyards, Commerce (CM), Long Beach (LB), and San Bernardino (SB), were assessed by determination of chemical reactivities attributed to the induction of oxidative stress by air pollutants. The assays used were dithiothreitol (DTT) and dihydrobenzoic acid (DHBA) based procedures for prooxidant content and a glyceraldehyde-3-phosphate dehydrogenase (GAPDH) assay for electrophiles. Prooxidants and electrophiles have been proposed as the reactive chemical species responsible for the induction of oxidative stress by air pollution mixtures. The PM2.5 samples from CM and LB sites showed seasonal differences in reactivities with higher levels in the winter whereas the SB sample differences were reversed. The reactivities in the vapor samples were all very similar, except for the summer SB samples, which contained higher levels of both prooxidants and electrophiles. The results suggest the observed reactivities reflect general geographical differences rather than direct effects of the railyards. Distributional differences in reactivities were also observed with PM2.5 fractions containing most of the prooxidants (74–81%) and the vapor phase most of the electrophiles (82–96%). The high levels of the vapor phase electrophiles and their potential for adverse biological effects point out the importance of the vapor phase in assessing the potential health effects of ambient air. PMID:25947123

  2. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  3. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-105 at the Conclusion of 7A.1

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-105 (7 A.1) flight to the ISS is reported. ISS air samples were taken in August 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and surrogate standard recoveries were 64-115%. Pressure tracking indicated no leaks in the canisters.

  4. Semiautomatic nondispersive infrared analyzer apparatus for CO/sub 2/ air sample analyses

    SciTech Connect

    Komhyr, W.D.; Waterman, L.S.; Taylor, W.R.

    1983-02-20

    A semiautomatic nondispersive infrared analyzer apparatus has been developed for analysis of up to 50 CO/sub 2/ air samples per day. The samples are collected in 500-ml glass flasks and are transferred to the analyzer with a novel, free-floating piston pump. Sample and calibration gas transfer operations are controlled by a microprocessor, and data are recorded, analyzed, and output by a Hewlett-Packard 9845A/S desktop computer. The apparatus is described, including operating and test modes, and performance characteristics determined from 2 years of operation are given. 7 references, 5 figures, 5 tables.

  5. Report on sampling and analysis of exhaust air at the 221-T and 2706-T buildings

    SciTech Connect

    Stauffer, M.

    1997-09-22

    This report presents analytical results from exhaust air samples collected at stacks 221-T and 2706-T of the T-Plant. The samples were collected with SUMMA canisters over a 24 hour interval and were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data suggest that the buildings had generally low concentrations of volatile organic compounds (< 40 ppbv). However, samples from building 2706-T did have significant amounts of non-target higher-boiling hydrocarbons, probably from a petroleum destination fraction.

  6. Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-102 at the Conclusion of 5A.1

    NASA Technical Reports Server (NTRS)

    James, John T.

    2001-01-01

    The toxicological assessment of air samples returned at the end of the STS-102 (5A.1) flight to the ISS is reported. ISS air samples were taken in late February 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges . A "first-entry" sample of the multipurpose logistics module (MPLM) atmosphere was taken with a GSC, and preflight and end-of-mission samples were obtained from Discovery using GSCs. Analytical methods have not changed from earlier reports, and all quality control measures were met for the data presented herein. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 contribution). Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols were also assessed in each sample. Formaldehyde is quantified separately.

  7. Volatile organic components of air samples collected from Vertical Launch Missile capsules. Summary report

    SciTech Connect

    Tappan, D.V.; Knight, D.R.; Heyder, E.; Weathersby, P.K.

    1988-09-27

    Gas chromatographic/mass spectroscopic analyses are presented for the volatile organic components found in air samples collected from the inboard vents from Vertical Launch System (VLS) missile capsules aboard a 688 class submarine. Similar analyses were also conducted for a sample of the ship's high pressure air used to fill the missile tubes. A wide variety of organics was detected in the air from the missile capsules; and while no unique components have yet been identified, a significant contribution has been shown to be made by pressure-ventilation of the VLS capsules into the submarine atmosphere which is already heavily laden with volatile organic compounds. The most apparent conclusion from these preliminary analyses is that the mixtures of organic components in the air within VLS missile capsules vary greatly from capsule to capsule (and probably from time to time). Many such samples need to be investigated to provide sufficient information to judge the seriousness of the possibility of venting toxic components into the submarine atmosphere during the maintenance or firing of VLS missiles.

  8. Monitoring of air pollution by plants methods and problems

    SciTech Connect

    Steubing, L.; Jager, H.J.

    1985-01-01

    Ecosystem pollution is often discovered too late for preventive measure to be implemented. Papers include the topics of methods and problems of bioindication of air pollution. The participants discussed passive and active biological monitoring, including mapping of natural vegetation (lichens and mosses, for example) and plant exposure. Morphological and microscopical studies, chemical, physiological and biochemical investigations are presented.

  9. A rapid method for the computation of equilibrium chemical composition of air to 15000 K

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.; Erickson, Wayne D.

    1988-01-01

    A rapid computational method has been developed to determine the chemical composition of equilibrium air to 15000 K. Eleven chemically reacting species, i.e., O2, N2, O, NO, N, NO+, e-, N+, O+, Ar, and Ar+ are included. The method involves combining algebraically seven nonlinear equilibrium equations and four linear elemental mass balance and charge neutrality equations. Computational speeds for determining the equilibrium chemical composition are significantly faster than the often used free energy minimization procedure. Data are also included from which the thermodynamic properties of air can be computed. A listing of the computer program together with a set of sample results are included.

  10. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING AIR SAMPLES FOR ANALYSIS OF NEUTRAL PERSISTENT ORGANIC POLLUTANTS (SOP-5.12)

    EPA Science Inventory

    The method is for extracting an indoor and outdoor air sample consisting of a quartz fiber filter and an XAD-2 cartridge for analysis of neutral persistent organic pollutants. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass...

  11. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  12. Application of the SAMR method to high magnetostrictive samples

    NASA Astrophysics Data System (ADS)

    Sanchez, P.; Lopez, E.; Trujillo, M. C. Sanchez; Aroca, C.

    1988-12-01

    Magnetostriction measurement by using the small angle magnetization rotation method (SAMR) has been performed in high magnetostrictive amorphous samples. To apply the SAMR method to these samples, a theoritical model about the influence of the internal stresses and magnetization distribution has been proposed. The dependence of the magnetostriction, λ s, with the temperature and applied stress was measured in as-cast and in different annealed samples. In the as-cast samples the existence of a stray field and a dependence of λ s with the applied stress has been observed.

  13. Monitoring of ozone precursors in ambient air using pumped and diffusive sampling on the sorbent Carbopack X

    NASA Astrophysics Data System (ADS)

    Quincey, Paul; Butterfield, David; D'Souza, Hansa; Henderson, Malcolm

    EU legislation for ambient ozone concentrations puts a requirement on Member States to monitor a large set of ozone precursor species, mostly hydrocarbons. We describe an investigation into how much of this information is readily available from manual methods used routinely for benzene monitoring in the United Kingdom, using pumped or diffusive sampling of ambient air onto the sorbent Carbopack X, followed by thermal desorption and gas chromatography with a flame ionisation detector. Identifiable peaks were assessed for reliability by comparison with independent automated measurements and emissions inventories. We conclude that 21 of the 29 specified hydrocarbons can be usefully monitored without any change to the methods used.

  14. Methods of Visually Determining the Air Flow Around Airplanes

    NASA Technical Reports Server (NTRS)

    Gough, Melvin N; Johnson, Ernest

    1932-01-01

    This report describes methods used by the National Advisory Committee for Aeronautics to study visually the air flow around airplanes. The use of streamers, oil and exhaust gas streaks, lampblack and kerosene, powdered materials, and kerosene smoke is briefly described. The generation and distribution of smoke from candles and from titanium tetrachloride are described in greater detail because they appear most advantageous for general application. Examples are included showing results of the various methods.

  15. High-throughput liquid-absorption preconcentrator sampling methods

    DOEpatents

    Zaromb, Solomon

    1994-01-01

    A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis.

  16. Method for using polarization gating to measure a scattering sample

    DOEpatents

    Baba, Justin S.

    2015-08-04

    Described herein are systems, devices, and methods facilitating optical characterization of scattering samples. A polarized optical beam can be directed to pass through a sample to be tested. The optical beam exiting the sample can then be analyzed to determine its degree of polarization, from which other properties of the sample can be determined. In some cases, an apparatus can include a source of an optical beam, an input polarizer, a sample, an output polarizer, and a photodetector. In some cases, a signal from a photodetector can be processed through attenuation, variable offset, and variable gain.

  17. Results of a Self-Absorption Study on the Versapor 3000 47-mm Filters for Radioactive Particulate Air Stack Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-11-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor® 3000, 47-mm diameter) used at PNNL for self absorption effects. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Large error is associated with the sample filter analysis comparison and subsequently with the estimation of the absorption factor resulting in an inadequate method to estimate losses from self-absorption in the sample filter. The mass loading on the sample filter as determined after digestion and drying was ~0.08 mg cm-2; however, this value may not represent the total filter mass loading given that there may be undetermined losses associated with the digestion process. While it is difficult to determine how much material is imbedded in the filter, observations from the microscopy analysis indicate that the vast majority of the particles remain on the top of the filter. In comparing the results obtained, the continued use of 0.85 as a conservative correction factor is recommended.

  18. Interval sampling methods and measurement error: a computer simulation.

    PubMed

    Wirth, Oliver; Slaven, James; Taylor, Matthew A

    2014-01-01

    A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments.

  19. [Recent advances in sample preparation methods of plant hormones].

    PubMed

    Wu, Qian; Wang, Lus; Wu, Dapeng; Duan, Chunfeng; Guan, Yafeng

    2014-04-01

    Plant hormones are a group of naturally occurring trace substances which play a crucial role in controlling the plant development, growth and environment response. With the development of the chromatography and mass spectroscopy technique, chromatographic analytical method has become a widely used way for plant hormone analysis. Among the steps of chromatographic analysis, sample preparation is undoubtedly the most vital one. Thus, a highly selective and efficient sample preparation method is critical for accurate identification and quantification of phytohormones. For the three major kinds of plant hormones including acidic plant hormones & basic plant hormones, brassinosteroids and plant polypeptides, the sample preparation methods are reviewed in sequence especially the recently developed methods. The review includes novel methods, devices, extractive materials and derivative reagents for sample preparation of phytohormones analysis. Especially, some related works of our group are included. At last, the future developments in this field are also prospected.

  20. A random spatial sampling method in a rural developing nation

    PubMed Central

    2014-01-01

    Background Nonrandom sampling of populations in developing nations has limitations and can inaccurately estimate health phenomena, especially among hard-to-reach populations such as rural residents. However, random sampling of rural populations in developing nations can be challenged by incomplete enumeration of the base population. Methods We describe a stratified random sampling method using geographical information system (GIS) software and global positioning system (GPS) technology for application in a health survey in a rural region of Guatemala, as well as a qualitative study of the enumeration process. Results This method offers an alternative sampling technique that could reduce opportunities for bias in household selection compared to cluster methods. However, its use is subject to issues surrounding survey preparation, technological limitations and in-the-field household selection. Application of this method in remote areas will raise challenges surrounding the boundary delineation process, use and translation of satellite imagery between GIS and GPS, and household selection at each survey point in varying field conditions. This method favors household selection in denser urban areas and in new residential developments. Conclusions Random spatial sampling methodology can be used to survey a random sample of population in a remote region of a developing nation. Although this method should be further validated and compared with more established methods to determine its utility in social survey applications, it shows promise for use in developing nations with resource-challenged environments where detailed geographic and human census data are less available. PMID:24716473

  1. Organophosphates in aircraft cabin and cockpit air--method development and measurements of contaminants.

    PubMed

    Solbu, Kasper; Daae, Hanne Line; Olsen, Raymond; Thorud, Syvert; Ellingsen, Dag Gunnar; Lindgren, Torsten; Bakke, Berit; Lundanes, Elsa; Molander, Paal

    2011-05-01

    Methods for measurements and the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils among flying personnel in the aviation industry are described. Different sampling methods were applied, including active within-day methods for OPs and VOCs, newly developed passive long-term sample methods (deposition of OPs to wipe surface areas and to activated charcoal cloths), and measurements of OPs in high-efficiency particulate air (HEPA) recirculation filters (n = 6). In total, 95 and 72 within-day OP and VOC samples, respectively, have been collected during 47 flights in six different models of turbine jet engine, propeller and helicopter aircrafts (n = 40). In general, the OP air levels from the within-day samples were low. The most relevant OP in this regard originating from turbine and engine oils, tricresyl phosphate (TCP), was detected in only 4% of the samples (min-max samples (n = 56) and in all HEPA-filters. Other OPs, as dibutylphenyl phosphate (DBPP) and tri-n-butyl phosphate (TnBP) originating from hydraulic oils were more prominent in the samples, illustrated by determination of TnBP in all of the within-day samples collected from airplanes (n = 76, min-max 0.02-4.1 µg m(-3)). All samples were collected under normal flight conditions. However, the TCP concentration during ground testing in an airplane that had experienced leakage of turbine oil with subsequent contamination of the cabin and cockpit air, was an order of magnitude higher as compared to after engine replacement (p = 0.02).

  2. Organophosphates in aircraft cabin and cockpit air--method development and measurements of contaminants.

    PubMed

    Solbu, Kasper; Daae, Hanne Line; Olsen, Raymond; Thorud, Syvert; Ellingsen, Dag Gunnar; Lindgren, Torsten; Bakke, Berit; Lundanes, Elsa; Molander, Paal

    2011-05-01

    Methods for measurements and the potential for occupational exposure to organophosphates (OPs) originating from turbine and hydraulic oils among flying personnel in the aviation industry are described. Different sampling methods were applied, including active within-day methods for OPs and VOCs, newly developed passive long-term sample methods (deposition of OPs to wipe surface areas and to activated charcoal cloths), and measurements of OPs in high-efficiency particulate air (HEPA) recirculation filters (n = 6). In total, 95 and 72 within-day OP and VOC samples, respectively, have been collected during 47 flights in six different models of turbine jet engine, propeller and helicopter aircrafts (n = 40). In general, the OP air levels from the within-day samples were low. The most relevant OP in this regard originating from turbine and engine oils, tricresyl phosphate (TCP), was detected in only 4% of the samples (min-max samples (n = 56) and in all HEPA-filters. Other OPs, as dibutylphenyl phosphate (DBPP) and tri-n-butyl phosphate (TnBP) originating from hydraulic oils were more prominent in the samples, illustrated by determination of TnBP in all of the within-day samples collected from airplanes (n = 76, min-max 0.02-4.1 µg m(-3)). All samples were collected under normal flight conditions. However, the TCP concentration during ground testing in an airplane that had experienced leakage of turbine oil with subsequent contamination of the cabin and cockpit air, was an order of magnitude higher as compared to after engine replacement (p = 0.02). PMID:21399836

  3. Method and sample spinning apparatus for measuring the NMR spectrum of an orientationally disordered sample

    DOEpatents

    Pines, Alexander; Samoson, Ago

    1990-01-01

    An improved NMR apparatus and method are described which substantially improve the resolution of NMR measurements made on powdered or amorphous or otherwise orientationally disordered samples. The apparatus spins the sample about an axis. The angle of the axis is mechanically varied such that the time average of two or more Legendre polynomials are zero.

  4. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  5. Nominal Weights Mean Equating: A Method for Very Small Samples

    ERIC Educational Resources Information Center

    Babcock, Ben; Albano, Anthony; Raymond, Mark

    2012-01-01

    The authors introduced nominal weights mean equating, a simplified version of Tucker equating, as an alternative for dealing with very small samples. The authors then conducted three simulation studies to compare nominal weights mean equating to six other equating methods under the nonequivalent groups anchor test design with sample sizes of 20,…

  6. Isolation of Legionella from water samples using various culture methods.

    PubMed

    Kusnetsov, J M; Jousimies-Somer, H R; Nevalainen, A I; Martikainen, P J

    1994-02-01

    The efficacy of a non-selective medium and two selective media were compared for the isolation of legionellas from water samples. The effect of acid wash treatment for decontamination of the water samples on the isolation frequency of legionellas was also studied. The 236 samples were taken from cooling, humidifying and drinking water systems; 21% were legionella-positive when inoculated directly on modified Wadowsky-Yee (MWY) medium and 26% were positive when concentrated (x 200) before cultivation on MWY or CCVC media. Inoculation on MWY medium after concentration followed by decontamination by the acid-wash technique gave the highest isolation frequency (31%). The lowest frequency (8%) was found with the non-selective BCYE alpha medium. An isolation frequency of 28% was achieved with the BCYE alpha medium after concentration and acid-wash treatment of the samples. Forty per cent of the samples were positive for legionellas when the results from all the culture methods were combined. Not all the legionella-positive samples were identified by a single culture method. Ninety-three of the 95 positive samples were detected with the two best combinations of three culture methods. The best culture method for detecting legionellas depended on the source of the water sample. Some water quality characteristics, like temperature and organic matter content, affected the isolation frequency of Legionella spp.

  7. A cryopreservation method for Pasteurella multocida from wetland samples

    USGS Publications Warehouse

    Moore, Melody K.; Shadduck, D.J.; Goldberg, D.R.; Samuel, M.D.

    1998-01-01

    A cryopreservation method and improved isolation techniques for detection of Pasteurella multocida from wetland samples were developed. Wetland water samples were collected in the field, diluted in dimethyl sulfoxide (DMSO, final concentration 10%), and frozen at -180 C in a liquid nitrogen vapor shipper. Frozen samples were transported to the laboratory where they were subsequently thawed and processed in Pasteurella multocida selective broth (PMSB) to isolate P. multocida. This method allowed for consistent isolation of 2 to 18 organisms/ml from water seeded with known concentrations of P. multocida. The method compared favorably with the standard mouse inoculation method and allowed for preservation of the samples until they could be processed in the laboratory.

  8. STS-65 Commander Cabana and PLC Hieb take air sample at IML-2 Rack 7 NIZEMI

    NASA Technical Reports Server (NTRS)

    1994-01-01

    STS-65 Commander Robert D. Cabana (right) and Payload Commander (PLC) Richard J. Hieb take an air sample inside the International Microgravity Laboratory 2 (IML-2) spacelab science module. The two crewmembers are in front of Rack 7 which contains the large isothermal furnace (LIF) and slow rotating centrifuge microscope (NIZEMI). The photo was among the first group released by NASA following the two-week IML-2 mission aboard the Space Shuttle Columbia, Orbiter Vehicle (OV) 102.

  9. Probability Sampling Method for a Hidden Population Using Respondent-Driven Sampling: Simulation for Cancer Survivors.

    PubMed

    Jung, Minsoo

    2015-01-01

    When there is no sampling frame within a certain group or the group is concerned that making its population public would bring social stigma, we say the population is hidden. It is difficult to approach this kind of population survey-methodologically because the response rate is low and its members are not quite honest with their responses when probability sampling is used. The only alternative known to address the problems caused by previous methods such as snowball sampling is respondent-driven sampling (RDS), which was developed by Heckathorn and his colleagues. RDS is based on a Markov chain, and uses the social network information of the respondent. This characteristic allows for probability sampling when we survey a hidden population. We verified through computer simulation whether RDS can be used on a hidden population of cancer survivors. According to the simulation results of this thesis, the chain-referral sampling of RDS tends to minimize as the sample gets bigger, and it becomes stabilized as the wave progresses. Therefore, it shows that the final sample information can be completely independent from the initial seeds if a certain level of sample size is secured even if the initial seeds were selected through convenient sampling. Thus, RDS can be considered as an alternative which can improve upon both key informant sampling and ethnographic surveys, and it needs to be utilized for various cases domestically as well. PMID:26107223

  10. Probability Sampling Method for a Hidden Population Using Respondent-Driven Sampling: Simulation for Cancer Survivors.

    PubMed

    Jung, Minsoo

    2015-01-01

    When there is no sampling frame within a certain group or the group is concerned that making its population public would bring social stigma, we say the population is hidden. It is difficult to approach this kind of population survey-methodologically because the response rate is low and its members are not quite honest with their responses when probability sampling is used. The only alternative known to address the problems caused by previous methods such as snowball sampling is respondent-driven sampling (RDS), which was developed by Heckathorn and his colleagues. RDS is based on a Markov chain, and uses the social network information of the respondent. This characteristic allows for probability sampling when we survey a hidden population. We verified through computer simulation whether RDS can be used on a hidden population of cancer survivors. According to the simulation results of this thesis, the chain-referral sampling of RDS tends to minimize as the sample gets bigger, and it becomes stabilized as the wave progresses. Therefore, it shows that the final sample information can be completely independent from the initial seeds if a certain level of sample size is secured even if the initial seeds were selected through convenient sampling. Thus, RDS can be considered as an alternative which can improve upon both key informant sampling and ethnographic surveys, and it needs to be utilized for various cases domestically as well.

  11. Organic toxicants in air and precipitation samples from the Lake Michigan area

    SciTech Connect

    Harlin, K.S.; Sweet, C.W.; Gatz, D.F.

    1995-12-31

    Measurements of PCBs, organochlorine insecticides, PAHs, and atrazine were made in air and precipitation samples collected at regionally-representative locations near Lake Michigan from 1992-1995. The purpose of these measurements was to provide information needed to estimate the atmospheric deposition of organic toxicants to Lake Michigan. Twenty-four hour samples of airborne particles and vapor were collected at 12-day intervals on quartz fiber filters and XAD-2 resin vapor traps using modified high volume sampleers. Twenty-eight day precipitation samples were collected using wet-only samplers with stainless steel sampling surfaces and heated enclosure containing an XAD-2 resin adsorption column. Samples were Soxhlet extracted for 24 hours with hexane:acetone (1:1), and concentrated by rotary evaporation. Interferences were removed and the samples separated into analyte groups by silica gel chromatography. Four fractions were collected for GC-ECD and GC-Ion Trap MS analyses. Ten pesticides, 101 PCB congeners, 18 PAHs, and atrazine were measured in all samples. Quality assurance was maintained by including field duplicate samples, field blanks, alboratory matrix spikes, laboratory matrix blanks, and laboratory surrogate spikes in the sampling/analytical protocols. Preliminary results from urban and remote sites show geographical variations in the concentrations of some toxicants due to contributions from local sources. For all sites the total PCB levels are higher in the vapor phase than the particulate phase and show strong seasonal variations. Seasonal variations were also observed for several pesticides.

  12. Technical assessment of TRUSAF for compliance with work place air sampling. Revision 1

    SciTech Connect

    Butler, J.D.

    1995-01-23

    The purpose of this Technical Work Document is to satisfy WHC-CM-1-6, the ``WHC Radiological Control Manual.`` This first revision of the original Supporting Document covers the period from January 1, 1994 to December 31, 1994. WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. this document also provides an evaluation of the compliance of the TRUSAF workplace air sampling program to the criteria, standards, and requirements and documents. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  13. Polyurethane foam (PUF) disks passive air samplers: wind effect on sampling rates.

    PubMed

    Tuduri, Ludovic; Harner, Tom; Hung, Hayley

    2006-11-01

    Different passive sampler housings were evaluated for their wind dampening ability and how this might translate to variability in sampler uptake rates. Polyurethane foam (PUF) disk samplers were used as the sampling medium and were exposed to a PCB-contaminated atmosphere in a wind tunnel. The effect of outside wind speed on PUF disk sampling rates was evaluated by exposing polyurethane foam (PUF) disks to a PCB-contaminated air stream in a wind tunnel over air velocities in the range 0 to 1.75 m s-1. PUF disk sampling rates increased gradually over the range 0-0.9 m s-1 at approximately 4.5-14.6 m3 d-1 and then increased sharply to approximately 42 m3 d-1 at approximately 1.75 m s-1 (sum of PCBs). The results indicate that for most field deployments the conventional 'flying saucer' housing adequately dampens the wind effect and will yield approximately time-weighted air concentrations.

  14. Microbial Air and Surface Monitoring Results from International Space Station Samples

    NASA Technical Reports Server (NTRS)

    Ott, C. Mark; Bruce, Rebekah J.; Castro, Victoria A.; Novikova, Natalia D.; Pierson, D. L.

    2005-01-01

    Over the course of long-duration spaceflight, spacecraft develop a microbial ecology that directly interacts with the crew of the vehicle. While most microorganisms are harmless or beneficial to the inhabitants of the vehicle, the presence of medically significant organisms appearing in this semi-closed environment could adversely affect crew health and performance. The risk of exposure of the crew to medically significant organisms during a mission is estimated using information gathered during nominal and contingency environmental monitoring. Analysis of the air and surface microbiota in the habitable compartments of the International Space Station (ISS) over the last four years indicate a high presence of Staphylococcus species reflecting the human inhabitants of the vehicle. Generally, air and surface microbial concentrations are below system design specifications, suggesting a lower risk of contact infection or biodegradation. An evaluation of sample frequency indicates a decrease in the identification of new species, suggesting a lower potential for unknown microorganisms to be identified. However, the opportunistic pathogen, Staphylococcus aureus, has been identified in 3 of the last 5 air samples and 5 of the last 9 surface samples. In addition, 47% of the coagulase negative Staphylococcus species that were isolated from the crew, ISS, and its hardware were found to be methicillin resistance. In combination, these observations suggest the potential of methicillin resistant infectious agents over time.

  15. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 1

    SciTech Connect

    Olsen, P.A.

    1994-09-21

    WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE N 5480.6 ``US Department of Energy Radiological Control Manual`` as it applies to programs at Hanford which are now overseen by WHC. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of Tank Farms` workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  16. Aerostat-lofted instrument and sampling method for determination of emissions from open area sources.

    PubMed

    Aurell, Johanna; Gullett, Brian K; Pressley, Christopher; Tabor, Dennis G; Gribble, Robert D

    2011-10-01

    An aerostat-borne instrument and sampling method was developed to characterize air samples from area sources, such as emissions from open burning. The 10 kg battery-powered instrument system, termed "the Flyer", is lofted with a helium-filled aerostat of 4m nominal diameter and maneuvered by means of one or two tethers. The Flyer can be configured variously for continuous CO₂ monitoring, batch sampling of semi-volatile organic compounds (SVOCs), volatile organic compounds (VOCs), black carbon, metals, and PM by size. The samplers are controlled by a trigger circuit to avoid unnecessary dilution from background sampling when not within the source plume. The aerostat/Flyer method was demonstrated by sampling emissions from open burning (OB) and open detonation (OD) of military ordnance. A carbon balance approach was used to derive emission factors that showed excellent agreement with published values.

  17. ASSESSMENT OF VAPOR INTRUSION USING INDOOR AND SUB-SLAB AIR SAMPLING

    EPA Science Inventory

    The objective of this investigation was to develop a method for evaluating vapor intrusion using indoor and sub-slab air measurement and at the same time directly assist EPA’s New England Regional Office in evaluating vapor intrusion in 15 homes and one business near the former R...

  18. Ultimate detectability of volatile organic compounds: how much further can we reduce their ambient air sample volumes for analysis?

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2012-10-01

    To understand the ultimately lowest detection range of volatile organic compounds (VOCs) in air, application of a high sensitivity analytical system was investigated by coupling thermal desorption (TD) technique with gas chromatography (GC) and time-of-flight (TOF) mass spectrometry (MS). The performance of the TD-GC/TOF MS system was evaluated using liquid standards of 19 target VOCs prepared in the range of 35 pg to 2.79 ng per μL. Studies were carried out using both total ion chromatogram (TIC) and extracted ion chromatogram (EIC) mode. EIC mode was used for calibration to reduce background and to improve signal-to-noise. The detectability of 19 target VOCs, if assessed in terms of method detection limit (MDL, per US EPA definition) and limit of detection (LOD), averaged 5.90 pg and 0.122 pg, respectively, with the mean coefficient of correlation (R(2)) of 0.9975. The minimum quantifiable mass of target analytes, when determined using real air samples by the TD-GC/TOF MS, is highly comparable to the detection limits determined experimentally by standard. In fact, volumes for the actual detection of the major aromatic VOCs like benzene, toluene, and xylene (BTX) in ambient air samples were as low as 1.0 mL in the 0.11-2.25 ppb range. It was thus possible to demonstrate that most target compounds including those in low abundance could be reliably quantified at concentrations down to 0.1 ppb at sample volumes of less than 10 mL. The unique sensitivity of this advanced analytical system can ultimately lead to a shift in field sampling strategy with smaller air sample volumes facilitating faster, simpler air sampling (e.g., use of gas syringes rather than the relative complexity of pumps or bags/canisters), with greatly reduced risk of analyte breakthrough and minimal interference, e.g., from atmospheric humidity. The improved detection limits offered by this system can also enhance accuracy and measurement precision. PMID:22934885

  19. Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.

    2011-07-20

    This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

  20. A new analysis system for whole air sampling: description and results from 2013 SENEX

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Gilman, J.; Dumas, M.; Hughes, D.; Jaksich, A.; Hatch, C. D.; Graus, M.; Warneke, C.; Apel, E. C.; Hornbrook, R. S.; Holloway, J. S.; De Gouw, J. A.

    2014-12-01

    Accurate measurement of volatile organic compounds (VOCs) in the troposphere is critical for the understanding of emissions and physical and chemical processes that can impact both air quality and climate. Airborne VOC measurements have proven especially challenging due to the requirement of both high sensitivity (pptv) and short sample collection times (≤15 s) to maximize spatial resolution and sampling frequency for targeted plume analysis. The use of stainless steel canisters to collect whole air samples (WAS) for post-flight analysis has been pioneered by the groups of D. Blake and E. Atlas [Blake et al., 1992; Atlas et al., 1993]. For the 2013 Southeast Nexus Study (SENEX), the NOAA ESRL CSD laboratory undertook WAS measurements for the first time. This required the construction of three new, highly-automated, and field-portable instruments designed to sample, analyze, and clean the canisters for re-use. Analysis was performed with a new custom-built gas chromatograph-mass spectrometer system. The instrument pre-concentrates analyte cryostatically into two parallel traps by means of a Stirling engine, a novel technique which obviates the need for liquid nitrogen to reach trapping temperatures of -175C. Here we present an evaluation of the retrieval of target VOC species from WAS canisters. We discuss the effects of humidity and sample age on the analyte, particularly upon C8+ alkane and aromatic species and biogenic species. Finally, we present results from several research flights during SENEX that targeted emissions from oil/natural gas production.

  1. Methods of human body odor sampling: the effect of freezing.

    PubMed

    Lenochova, Pavlina; Roberts, S Craig; Havlicek, Jan

    2009-02-01

    Body odor sampling is an essential tool in human chemical ecology research. However, methodologies of individual studies vary widely in terms of sampling material, length of sampling, and sample processing. Although these differences might have a critical impact on results obtained, almost no studies test validity of current methods. Here, we focused on the effect of freezing samples between collection and use in experiments involving body odor perception. In 2 experiments, we tested whether axillary odors were perceived differently by raters when presented fresh or having been frozen and whether several freeze-thaw cycles affected sample quality. In the first experiment, samples were frozen for 2 weeks, 1 month, or 4 months. We found no differences in ratings of pleasantness, attractiveness, or masculinity between fresh and frozen samples. Similarly, almost no differences between repeatedly thawed and fresh samples were found. We found some variations in intensity; however, this was unrelated to length of storage. The second experiment tested differences between fresh samples and those frozen for 6 months. Again no differences in subjective ratings were observed. These results suggest that freezing has no significant effect on perceived odor hedonicity and that samples can be reliably used after storage for relatively long periods.

  2. Method and apparatus for imaging a sample on a device

    DOEpatents

    Trulson, Mark; Stern, David; Fiekowsky, Peter; Rava, Richard; Walton, Ian; Fodor, Stephen P. A.

    1996-01-01

    The present invention provides methods and systems for detecting a labeled marker on a sample located on a support. The imaging system comprises a body for immobilizing the support, an excitation radiation source and excitation optics to generate and direct the excitation radiation at the sample. In response, labeled material on the sample emits radiation which has a wavelength that is different from the excitation wavelength, which radiation is collected by collection optics and imaged onto a detector which generates an image of the sample.

  3. System and method for measuring fluorescence of a sample

    SciTech Connect

    Riot, Vincent J

    2015-03-24

    The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

  4. DOE methods for evaluating environmental and waste management samples

    SciTech Connect

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  5. Convenient mounting method for electrical measurements of thin samples

    NASA Technical Reports Server (NTRS)

    Matus, L. G.; Summers, R. L.

    1986-01-01

    A method for mounting thin samples for electrical measurements is described. The technique is based on a vacuum chuck concept in which the vacuum chuck simultaneously holds the sample and established electrical contact. The mounting plate is composed of a glass-ceramic insulating material and the surfaces of the plate and vacuum chuck are polished. The operation of the vacuum chuck is examined. The contacts on the sample and mounting plate, which are sputter-deposited through metal masks, are analyzed. The mounting method was utilized for van der Pauw measurements.

  6. A quantitative evaluation of two methods for preserving hair samples

    USGS Publications Warehouse

    Roon, David A.; Waits, L.P.; Kendall, K.C.

    2003-01-01

    Hair samples are an increasingly important DNA source for wildlife studies, yet optimal storage methods and DNA degradation rates have not been rigorously evaluated. We tested amplification success rates over a one-year storage period for DNA extracted from brown bear (Ursus arctos) hair samples preserved using silica desiccation and -20C freezing. For three nuclear DNA microsatellites, success rates decreased significantly after a six-month time point, regardless of storage method. For a 1000 bp mitochondrial fragment, a similar decrease occurred after a two-week time point. Minimizing delays between collection and DNA extraction will maximize success rates for hair-based noninvasive genetic sampling projects.

  7. On the construction, comparison, and variability of airsheds for interpreting semivolatile organic compounds in passively sampled air.

    PubMed

    Westgate, John N; Wania, Frank

    2011-10-15

    Air mass origin as determined by back trajectories often aids in explaining some of the short-term variability in the atmospheric concentrations of semivolatile organic contaminants. Airsheds, constructed by amalgamating large numbers of back trajectories, capture average air mass origins over longer time periods and thus have found use in interpreting air concentrations obtained by passive air samplers. To explore some of their key characteristics, airsheds for 54 locations on Earth were constructed and compared for roundness, seasonality, and interannual variability. To avoid the so-called "pole problem" and to simplify the calculation of roundness, a "geodesic grid" was used to bin the back-trajectory end points. Departures from roundness were seen to occur at all latitudes and to correlate significantly with local slope but no strong relationship between latitude and roundness was revealed. Seasonality and interannual variability vary widely enough to imply that static models of transport are not sufficient to describe the proximity of an area to potential sources of contaminants. For interpreting an air measurement an airshed should be generated specifically for the deployment time of the sampler, especially when investigating long-term trends. Samples taken in a single season may not represent the average annual atmosphere, and samples taken in linear, as opposed to round, airsheds may not represent the average atmosphere in the area. Simple methods are proposed to ascertain the significance of an airshed or individual cell. It is recommended that when establishing potential contaminant source regions only end points with departure heights of less than ∼700 m be considered.

  8. Comparison of surface sampling methods for virus recovery from fomites.

    PubMed

    Julian, Timothy R; Tamayo, Francisco J; Leckie, James O; Boehm, Alexandria B

    2011-10-01

    The role of fomites in infectious disease transmission relative to other exposure routes is difficult to discern due, in part, to the lack of information on the level and distribution of virus contamination on surfaces. Comparisons of studies intending to fill this gap are difficult because multiple different sampling methods are employed and authors rarely report their method's lower limit of detection. In the present study, we compare a subset of sampling methods identified from a literature review to demonstrate that sampling method significantly influences study outcomes. We then compare a subset of methods identified from the review to determine the most efficient methods for recovering virus from surfaces in a laboratory trial using MS2 bacteriophage as a model virus. Recoveries of infective MS2 and MS2 RNA are determined using both a plaque assay and quantitative reverse transcription-PCR, respectively. We conclude that the method that most effectively recovers virus from nonporous fomites uses polyester-tipped swabs prewetted in either one-quarter-strength Ringer's solution or saline solution. This method recovers a median fraction for infective MS2 of 0.40 and for MS2 RNA of 0.07. Use of the proposed method for virus recovery in future fomite sampling studies would provide opportunities to compare findings across multiple studies.

  9. The nature of air pollution and the methods available for measuring it

    PubMed Central

    Ellison, J. McK.

    1965-01-01

    At present the principal sources of energy in Europe are coal and oil and fuels derived from them, and in European towns air pollution consists mainly of their combustion products. These combustion products naturally divide into two categories, gaseous and particulate, which are very different chemically and which behave very differently when they are near collecting surfaces; they therefore require very different techniques both for collecting and for estimating samples. Some methods of measurement, suitable for everyday routine use in Europe, are described; these offer a compromise between completeness and economy, and can help to give a general outline of the air pollution situation without undue complexity or prohibitive cost. PMID:14315712

  10. Evaluating Composite Sampling Methods of Bacillus Spores at Low Concentrations

    PubMed Central

    Hess, Becky M.; Amidan, Brett G.; Anderson, Kevin K.; Hutchison, Janine R.

    2016-01-01

    Restoring all facility operations after the 2001 Amerithrax attacks took years to complete, highlighting the need to reduce remediation time. Some of the most time intensive tasks were environmental sampling and sample analyses. Composite sampling allows disparate samples to be combined, with only a single analysis needed, making it a promising method to reduce response times. We developed a statistical experimental design to test three different composite sampling methods: 1) single medium single pass composite (SM-SPC): a single cellulose sponge samples multiple coupons with a single pass across each coupon; 2) single medium multi-pass composite: a single cellulose sponge samples multiple coupons with multiple passes across each coupon (SM-MPC); and 3) multi-medium post-sample composite (MM-MPC): a single cellulose sponge samples a single surface, and then multiple sponges are combined during sample extraction. Five spore concentrations of Bacillus atrophaeus Nakamura spores were tested; concentrations ranged from 5 to 100 CFU/coupon (0.00775 to 0.155 CFU/cm2). Study variables included four clean surface materials (stainless steel, vinyl tile, ceramic tile, and painted dry wallboard) and three grime coated/dirty materials (stainless steel, vinyl tile, and ceramic tile). Analysis of variance for the clean study showed two significant factors: composite method (p< 0.0001) and coupon material (p = 0.0006). Recovery efficiency (RE) was higher overall using the MM-MPC method compared to the SM-SPC and SM-MPC methods. RE with the MM-MPC method for concentrations tested (10 to 100 CFU/coupon) was similar for ceramic tile, dry wall, and stainless steel for clean materials. RE was lowest for vinyl tile with both composite methods. Statistical tests for the dirty study showed RE was significantly higher for vinyl and stainless steel materials, but lower for ceramic tile. These results suggest post-sample compositing can be used to reduce sample analysis time when

  11. Learning styles: The learning methods of air traffic control students

    NASA Astrophysics Data System (ADS)

    Jackson, Dontae L.

    In the world of aviation, air traffic controllers are an integral part in the overall level of safety that is provided. With a number of controllers reaching retirement age, the Air Traffic Collegiate Training Initiative (AT-CTI) was created to provide a stronger candidate pool. However, AT-CTI Instructors have found that a number of AT-CTI students are unable to memorize types of aircraft effectively. This study focused on the basic learning styles (auditory, visual, and kinesthetic) of students and created a teaching method to try to increase memorization in AT-CTI students. The participants were asked to take a questionnaire to determine their learning style. Upon knowing their learning styles, participants attended two classroom sessions. The participants were given a presentation in the first class, and divided into a control and experimental group for the second class. The control group was given the same presentation from the first classroom session while the experimental group had a group discussion and utilized Middle Tennessee State University's Air Traffic Control simulator to learn the aircraft types. Participants took a quiz and filled out a survey, which tested the new teaching method. An appropriate statistical analysis was applied to determine if there was a significant difference between the control and experimental groups. The results showed that even though the participants felt that the method increased their learning, there was no significant difference between the two groups.

  12. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    PubMed

    Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  13. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  14. Evaluation of an ambient air sampling system for tritium (as tritiated water vapor) using silica gel adsorbent columns

    SciTech Connect

    Patton, G.W.; Cooper, A.T.; Tinker, M.R.

    1995-08-01

    Ambient air samples for tritium analysis (as the tritiated water vapor [HTO] content of atmospheric moisture) are collected for the Hanford Site Surface Environmental Surveillance Project (SESP) using the solid adsorbent silica gel. The silica gel has a moisture sensitive indicator which allows for visual observation of moisture movement through a column. Despite using an established method, some silica gel columns showed a complete change in the color indicator for summertime samples suggesting that breakthrough had occurred; thus a series of tests was conducted on the sampling system in an environmental chamber. The purpose of this study was to determine the maximum practical sampling volume and overall collection efficiency for water vapor collected on silica gel columns. Another purpose was to demonstrate the use of an impinger-based system to load water vapor onto silica gel columns to provide realistic analytical spikes and blanks for the Hanford Site SESP. Breakthrough volumes (V{sub b}) were measured and the chromatographic efficiency (expressed as the number of theoretical plates [N]) was calculated for a range of environmental conditions. Tests involved visual observations of the change in the silica gel`s color indicator as a moist air stream was drawn through the column, measurement of the amount of a tritium tracer retained and then recovered from the silica gel, and gravimetric analysis for silica gel columns exposed in the environmental chamber.

  15. The Precision Efficacy Analysis for Regression Sample Size Method.

    ERIC Educational Resources Information Center

    Brooks, Gordon P.; Barcikowski, Robert S.

    The general purpose of this study was to examine the efficiency of the Precision Efficacy Analysis for Regression (PEAR) method for choosing appropriate sample sizes in regression studies used for precision. The PEAR method, which is based on the algebraic manipulation of an accepted cross-validity formula, essentially uses an effect size to…

  16. Apparatus and method for treating air from a turbocharger

    SciTech Connect

    Mann, D.O.

    1987-11-24

    This patent describes an apparatus for cooling and removing moisture from compressed air passing from a turbocharger and the like to an intake of an engine comprising: an air duct connecting the turbocharger to the intake of the engine; heat pipes extending across the air duct for receiving heat from the compressed air passing through the air duct; a portion of the heat pipes extending from the air duct into a zone of ambient air external to the air duct for transferring heat received from the compressed air to the ambient air thus cooling the compressed air; and a lower extension of the air duct forming a coalescer zone receiving the compressed air after cooling by the heat pipes extending across the air duct for removing moisture therefrom.

  17. Standard methods for sampling North American freshwater fishes

    USGS Publications Warehouse

    Bonar, Scott A.; Hubert, Wayne A.; Willis, David W.

    2009-01-01

    This important reference book provides standard sampling methods recommended by the American Fisheries Society for assessing and monitoring freshwater fish populations in North America. Methods apply to ponds, reservoirs, natural lakes, and streams and rivers containing cold and warmwater fishes. Range-wide and eco-regional averages for indices of abundance, population structure, and condition for individual species are supplied to facilitate comparisons of standard data among populations. Provides information on converting nonstandard to standard data, statistical and database procedures for analyzing and storing standard data, and methods to prevent transfer of invasive species while sampling.

  18. Development of a sensitive thermal desorption method for the determination of trihalomethanes in humid ambient and alveolar air.

    PubMed

    Caro, J; Gallego, M

    2008-08-15

    A sensitive and reliable method has been developed for the determination of trihalomethanes (THMs) in air samples through adsorption in sorbent tubes and thermal desorption (TD) of the compounds, followed by gas chromatography (GC)-mass spectrometry (MS) analysis. Three commercial sorbent materials were compared in terms of adsorption efficiency and breakthrough volume, finding Chromosorb 102 to be the most appropriate adsorbent for air sampling. The method allows us to reach detection limits of 0.03 ng (0.01 microg m(-3) for 3 l of air), linear ranges from 0.1 to 2000 ng and specific uncertainties of ca. 5.0+/-0.2 ng for all THMs. Several salts were tested to reduce water retention (from the humid air of an indoor swimming pool) at the sampling stage, Na(2)SO(4) being the one that provides optimum efficiency. The method was validated by a new recovery study in which several tubes with and without adsorbent were spiked with THMs and analyzed by TD-GC/MS, recoveries ranging from 92% to 97% for all the compounds. Finally, the performance of the method was evaluated through the analysis of ambient air samples from an indoor swimming pool and alveolar air samples from swimmers to assess their THM uptake. THMs were found to be stable in the sorbent tubes for at least 1 month when stored at 4 degrees C.

  19. Occupational dimethylformamide exposure. 1. Diffusive sampling of dimethylformamide vapor for determination of time-weighted average concentration in air.

    PubMed

    Yasugi, T; Kawai, T; Mizunuma, K; Horiguchi, S; Iguchi, H; Ikeda, M

    1992-01-01

    A diffusive sampling method with water as absorbent was examined in comparison with 3 conventional methods of diffusive sampling with carbon cloth as absorbent, pumping through National Institute of Occupational Safety and Health (NIOSH) charcoal tubes, and pumping through NIOSH silica gel tubes to measure time-weighted average concentration of dimethylformamide (DMF). DMF vapors of constant concentrations at 3-110 ppm were generated by bubbling air at constant velocities through liquid DMF followed by dilution with fresh air. Both types of diffusive samplers could either absorb or adsorb DMF in proportion to time (0.25-8 h) and concentration (3-58 ppm), except that the DMF adsorbed was below the measurable amount when carbon cloth samplers were exposed at 3 ppm for less than 1 h. When both diffusive samplers were loaded with DMF and kept in fresh air, the DMF in water samplers stayed unchanged for at least for 12 h. The DMF in carbon cloth samplers showed a decay with a half-time of 14.3 h. When the carbon cloth was taken out immediately after termination of DMF exposure, wrapped in aluminum foil, and kept refrigerated, however, there was no measurable decrease in DMF for at least 3 weeks. When the air was drawn at 0.2 l/min, a breakthrough of the silica gel tube took place at about 4,000 ppm.min (as the lower 95% confidence limit), whereas charcoal tubes could tolerate even heavier exposures, suggesting that both tubes are fit to measure the 8-h time-weighted average of DMF at 10 ppm. PMID:1577523

  20. Urban air quality assessment using monitoring data of fractionized aerosol samples, chemometrics and meteorological conditions.

    PubMed

    Yotova, Galina I; Tsitouridou, Roxani; Tsakovski, Stefan L; Simeonov, Vasil D

    2016-01-01

    The present article deals with assessment of urban air by using monitoring data for 10 different aerosol fractions (0.015-16 μm) collected at a typical urban site in City of Thessaloniki, Greece. The data set was subject to multivariate statistical analysis (cluster analysis and principal components analysis) and, additionally, to HYSPLIT back trajectory modeling in order to assess in a better way the impact of the weather conditions on the pollution sources identified. A specific element of the study is the effort to clarify the role of outliers in the data set. The reason for the appearance of outliers is strongly related to the atmospheric condition on the particular sampling days leading to enhanced concentration of pollutants (secondary emissions, sea sprays, road and soil dust, combustion processes) especially for ultra fine and coarse particles. It is also shown that three major sources affect the urban air quality of the location studied-sea sprays, mineral dust and anthropogenic influences (agricultural activity, combustion processes, and industrial sources). The level of impact is related to certain extent to the aerosol fraction size. The assessment of the meteorological conditions leads to defining of four downwind patterns affecting the air quality (Pelagic, Western and Central Europe, Eastern and Northeastern Europe and Africa and Southern Europe). Thus, the present study offers a complete urban air assessment taking into account the weather conditions, pollution sources and aerosol fractioning.

  1. Sampling artifacts in active air sampling of semivolatile organic contaminants: Comparing theoretical and measured artifacts and evaluating implications for monitoring networks.

    PubMed

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Klánová, Jana

    2016-10-01

    The effects of sampling artifacts are often not fully considered in the design of air monitoring with active air samplers. Semivolatile organic contaminants (SVOCs) are particularly vulnerable to a range of sampling artifacts because of their wide range of gas-particle partitioning and degradation rates, and these can lead to erroneous measurements of air concentrations and a lack of comparability between sites with different environmental and sampling conditions. This study used specially adapted filter-sorbent sampling trains in three types of active air samplers to investigate breakthrough of SVOCs, and the possibility of other sampling artifacts. Breakthrough volumes were experimentally determined for a range of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in sampling volumes from 300 to 10,000 m(3), and sampling durations of 1-7 days. In parallel, breakthrough was estimated based on theoretical sorbent-vapor pressure relationships. The comparison of measured and theoretical determinations of breakthrough demonstrated good agreement between experimental and estimated breakthrough volumes, and showed that theoretical breakthrough estimates should be used when developing air monitoring protocols. Significant breakthrough in active air samplers occurred for compounds with vapor pressure >0.5 Pa at volumes <700 m(3). Sample volumes between 700 and 10,000 m(3) may lead to breakthrough for compounds with vapor pressures between 0.005 and 0.5 Pa. Breakthrough is largely driven by sample volume and compound volatility (therefore indirectly by temperature) and is independent of sampler type. The presence of significant breakthrough at "typical" sampling conditions is relevant for air monitoring networks, and may lead to under-reporting of more volatile SVOCs.

  2. Radiological air monitoring and sample analysis research and development progress report. Calendar year, 1992

    SciTech Connect

    Not Available

    1992-12-31

    Sponsored by a Department Of Energy (DOE) research and development grant, the State of Idaho INEL Oversight Program (OP) personnel designed an independent air monitoring system that provides detection of the presence of priority airborne contaminants potentially migrating beyond INEL boundaries. Initial locations for off-site ambient air monitoring stations were chosen in consultation with: DOE and NOAA reports; Mesodif modeling; review of the relevant literature; and communication with private contractors and experts in pertinent fields. Idaho State University (ISU) has initiated an Environmental Monitoring Program (EMP). The EMP provides an independent monitoring function as well as a training ground for students. Students learn research techniques dedicated to environmental studies and learn analytical skills and rules of compliance related to monitoring. ISU-EMP assisted OP in specific aspects of identifying optimum permanent monitoring station locations, and in selecting appropriate sample collection equipment for each station. The authorization to establish, prepare and install sampling devices on selected sites was obtained by OP personnel in conjunction with ISU-EMP personnel. All samples described in this program are collected by OP or ISU-EMP personnel and returned to the ISU for analysis. This report represents the summary of results of those samples collected and analyzed for radioactivity during the year of 1992.

  3. Beryllium Wipe Sampling (differing methods - differing exposure potentials)

    SciTech Connect

    Kerr, Kent

    2005-03-09

    This research compared three wipe sampling techniques currently used to test for beryllium contamination on room and equipment surfaces in Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling without a wetting agent, with water-moistened wipe materials, and by methanol-moistened wipes. Analysis indicated that methanol-moistened wipe sampling removed about twice as much beryllium/oil-film surface contamination as water-moistened wipes, which removed about twice as much residue as dry wipes. Criteria at 10 CFR 850.30 and .31 were established on unspecified wipe sampling method(s). The results of this study reveal a need to identify criteria-setting method and equivalency factors. As facilities change wipe sampling methods among the three compared in this study, these results may be useful for approximate correlations. Accurate decontamination decision-making depends on the selection of appropriate wetting agents for the types of residues and surfaces. Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced removal efficiency such as methanol when surface contamination includes oil mist residue.

  4. Summary of stationary and personal air sampling measurements made during a plutonium glovebox decommissioning project.

    SciTech Connect

    Munyon, W. J.; Lee, M. B.

    2002-02-01

    Workplace air sampling was performed during the decommissioning of a previously active plutonium glovebox facility located at Argonne National Laboratory. Personal air samplers (PAS) were used to measure breathing zone activity concentrations of workers engaged in size-reducing contaminated gloveboxes. Stationary air samplers (SAS) were used to measure the work area activity concentrations and test their application in providing representative sampling of breathing zone activity concentrations. The relative response of these samplers (PAS:SAS) was tracked during the course of the decommissioning work, with results yielding favorable agreement to within a factor of {+-}5. A cascade impactor was used to determine the particle size distribution of workplace aerosols. The average activity median aerodynamic diameter (AMAD) was estimated to be 3.0 {mu}m, with a corresponding geometric standard deviation of 2.4. A gas-flow proportional counter was utilized to measure the gross alpha activity collected on both the SAS glass fiber and the PAS cellulose fiber filters. A subset of this filter group was subsequently analyzed using an alpha spectrometer post radiochemical processing and isotopic separation. The quantity of alpha activity measured on the SAS filters was generally within {+-}30% of the alpha spectrometry measurements. However, measurements made of the activity present on the PAS cellulose fiber filters were consistently underestimated using a gas-flow proportional counter, suggesting a small correction factor of 15-20% to account for the absorption of alpha particle emissions.

  5. Mass spectrometry of solid samples in open air using combined laser ionization and ambient metastable ionization

    NASA Astrophysics Data System (ADS)

    He, X. N.; Xie, Z. Q.; Gao, Y.; Hu, W.; Guo, L. B.; Jiang, L.; Lu, Y. F.

    2012-01-01

    Mass spectrometry of solid samples in open air was carried out using combined laser ionization and metastable ionization time-of-flight mass spectrometry (LI-MI-TOFMS) in ambient environment for qualitative and semiquantitative (relative analyte information, not absolute information) analysis. Ambient metastable ionization using a direct analysis in realtime (DART) ion source was combined with laser ionization time-of-flight mass spectrometry (LI-TOFMS) to study the effects of combining metastable and laser ionization. A series of metallic samples from the National Institute of Standards and Technology (NIST 494, 495, 498, 499, and 500) and a pure carbon target were characterized using LI-TOFMS in open air. LI-MI-TOFMS was found to be superior to laser-induced breakdown spectroscopy (LIBS). Laser pulse energies between 10 and 200 mJ at the second harmonic (532 nm) of an Nd:YAG laser were applied in the experiment to obtain a high degree of ionization in plasmas. Higher laser pulse energy improves signal intensities of trace elements (such as Fe, Cr, Mn, Ni, Ca, Al, and Ag). Data were analyzed by numerically calculating relative sensitivity coefficients (RSCs) and limit of detections (LODs) from mass spectrometry (MS) and LIBS spectra. Different parameters, such as boiling point, ionization potential, RSC, LOD, and atomic weight, were shown to analyze the ionization and MS detection processes in open air.

  6. Summary of stationary and personal air sampling measurements made during a plutonium glovebox decommissioning project.

    PubMed

    Munyon, W J; Lee, M B

    2002-02-01

    Workplace air sampling was performed during the decommissioning of a previously active plutonium glovebox facility located at Argonne National Laboratory. Personal air samplers (PAS) were used to measure breathing zone activity concentrations of workers engaged in size-reducing contaminated gloveboxes. Stationary air samplers (SAS) were used to measure the work area activity concentrations and test their application in providing representative sampling of breathing zone activity concentrations. The relative response of these samplers (PAS:SAS) was tracked during the course of the decommissioning work, with results yielding favorable agreement to within a factor of +/-5. A cascade impactor was used to determine the particle size distribution of workplace aerosols. The average activity median aerodynamic diameter (AMAD) was estimated to be 3.0 microm, with a corresponding geometric standard deviation of 2.4. A gas-flow proportional counter was utilized to measure the gross alpha activity collected on both the SAS glass fiber and the PAS cellulose fiber filters. A subset of this filter group was subsequently analyzed using an alpha spectrometer post radiochemical processing and isotopic separation. The quantity of alpha activity measured on the SAS filters was generally within +/-30% of the alpha spectrometry measurements. However, measurements made of the activity present on the PAS cellulose fiber filters were consistently underestimated using a gas-flow proportional counter, suggesting a small correction factor of 15-20% to account for the absorption of alpha particle emissions.

  7. Identification of monochloro-nonabromodiphenyl ethers in the air and soil samples from south China.

    PubMed

    Yu, Zhiqiang; Zheng, Kewen; Ren, Guofa; Wang, Decheng; Ma, Shengtao; Peng, Pingan; Wu, Minghong; Sheng, Guoying; Fu, Jiamo

    2011-04-01

    Several studies have indicated that mixed brominated/chlorinated organic compounds could be formed during the thermal process such as the incineration of municipal solid waste and open burning of unregulated e-waste at recycling areas. In this study, air particles and soils from e-waste recycling areas, as well as outdoor and indoor air particles from urban Guangzhou, were collected and pooled for the identification of mixed chlorinated/brominated diphenyl ethers (PXDEs). Three monochloro-nonabromo diphenyl ethers (Cl-nonaBDEs), including 6'-Cl-BDE-206, 5'-Cl-BDE-207, and/or 4'-Cl-BDE-208, were first structurally identified in these air and soil samples. The identification was done by comparison of retention times in chromatograms of pure reference compounds and environmental samples, as well as by comparison with full-scan mass spectra data in electron capture negative ionization mode. Because of their similar physical-chemical properties, 4'-Cl-BDE-208 and 5'-Cl-BDE-207 absolutely coeluted, even on a nonpolar DB-5 column. Further investigation is still needed to clarify these findings. Nevertheless, the results indicated that Cl-nonaBDEs would occur in various environmental matrices. Because the replacement of Br by Cl will change the physical-chemical properties of PBDE analogues, environmental occurrence, fate, and transport, the potential toxicity of PXDEs should be investigated.

  8. Continuous air agglomeration method for high carbon fly ash beneficiation

    DOEpatents

    Gray, McMahon L.; Champagne, Kenneth J.; Finseth, Dennis H.

    2000-01-01

    The carbon and mineral components of fly ash are effectively separated by a continuous air agglomeration method, resulting in a substantially carboree mineral stream and a highly concentrated carbon product. The method involves mixing the fly ash comprised of carbon and inorganic mineral matter with a liquid hydrocarbon to form a slurry, contacting the slurry with an aqueous solution, dispersing the hydrocarbon slurry into small droplets within the aqueous solution by mechanical mixing and/or aeration, concentrating the inorganic mineral matter in the aqueous solution, agglomerating the carbon and hydrocarbon in the form of droplets, collecting the droplets, separating the hydrocarbon from the concentrated carbon product, and recycling the hydrocarbon.

  9. Glyphosate-rich air samples induce IL-33, TSLP and generate IL-13 dependent airway inflammation.

    PubMed

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A; Adhikari, Atin

    2014-11-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4-/-, and IL-13-/- mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease. PMID:25172162

  10. Glyphosate–rich air samples induce IL–33, TSLP and generate IL–13 dependent airway inflammation

    PubMed Central

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M.; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A.; Adhikari, Atin

    2014-01-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4−/−, and IL-13−/− mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease. PMID:25172162

  11. Glyphosate-rich air samples induce IL-33, TSLP and generate IL-13 dependent airway inflammation.

    PubMed

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A; Adhikari, Atin

    2014-11-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4-/-, and IL-13-/- mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease.

  12. Method to characterize collective impact of factors on indoor air

    NASA Astrophysics Data System (ADS)

    Szczurek, Andrzej; Maciejewska, Monika; Teuerle, Marek; Wyłomańska, Agnieszka

    2015-02-01

    One of the most important problems in studies of building environment is a description of how it is influenced by various dynamically changing factors. In this paper we characterized the joint impact of a collection of factors on indoor air quality (IAQ). We assumed that the influence is reflected in the temporal variability of IAQ parameters and may be deduced from it. The proposed method utilizes mean square displacement (MSD) analysis which was originally developed for studying the dynamics in various systems. Based on the MSD time-dependence descriptor β, we distinguished three types of the collective impact of factors on IAQ: retarding, stabilizing and promoting. We presented how the aggregated factors influence the temperature, relative humidity and CO2 concentration, as these parameters are informative for the condition of indoor air. We discovered, that during a model day there are encountered one, two or even three types of influence. The presented method allows us to study the impacts from the perspective of the dynamics of indoor air.

  13. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    NASA Astrophysics Data System (ADS)

    Khanh Huynh, Cong; Duc, Trinh Vu

    2009-02-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  14. 77 FR 55832 - Ambient Air Monitoring Reference and Equivalent Methods: Designation of a New Equivalent Method

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-11

    ... made under the provisions of 40 CFR part 53, as ] amended on August 31, 2011 (76 FR 54326-54341). The... AGENCY Ambient Air Monitoring Reference and Equivalent Methods: Designation of a New Equivalent Method AGENCY: Environmental Protection Agency. ACTION: Notice of the designation of a new equivalent method...

  15. Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

  16. Examination of Hydrate Formation Methods: Trying to Create Representative Samples

    SciTech Connect

    Kneafsey, T.J.; Rees, E.V.L.; Nakagawa, S.; Kwon, T.-H.

    2011-04-01

    Forming representative gas hydrate-bearing laboratory samples is important so that the properties of these materials may be measured, while controlling the composition and other variables. Natural samples are rare, and have often experienced pressure and temperature changes that may affect the property to be measured [Waite et al., 2008]. Forming methane hydrate samples in the laboratory has been done a number of ways, each having advantages and disadvantages. The ice-to-hydrate method [Stern et al., 1996], contacts melting ice with methane at the appropriate pressure to form hydrate. The hydrate can then be crushed and mixed with mineral grains under controlled conditions, and then compacted to create laboratory samples of methane hydrate in a mineral medium. The hydrate in these samples will be part of the load-bearing frame of the medium. In the excess gas method [Handa and Stupin, 1992], water is distributed throughout a mineral medium (e.g. packed moist sand, drained sand, moistened silica gel, other porous media) and the mixture is brought to hydrate-stable conditions (chilled and pressurized with gas), allowing hydrate to form. This method typically produces grain-cementing hydrate from pendular water in sand [Waite et al., 2004]. In the dissolved gas method [Tohidi et al., 2002], water with sufficient dissolved guest molecules is brought to hydrate-stable conditions where hydrate forms. In the laboratory, this is can be done by pre-dissolving the gas of interest in water and then introducing it to the sample under the appropriate conditions. With this method, it is easier to form hydrate from more soluble gases such as carbon dioxide. It is thought that this method more closely simulates the way most natural gas hydrate has formed. Laboratory implementation, however, is difficult, and sample formation is prohibitively time consuming [Minagawa et al., 2005; Spangenberg and Kulenkampff, 2005]. In another version of this technique, a specified quantity of gas

  17. Trace Analysis in End-Exhaled Air Using Direct Solvent Extraction in Gas Sampling Tubes: Tetrachloroethene in Workers as an Example

    PubMed Central

    Braunsdorf, Pia-Paulin

    2014-01-01

    Simple and cost-effective analytical methods are required to overcome the barriers preventing the use of exhaled air in routine occupational biological monitoring. Against this background, a new method is proposed that simplifies the automation and calibration of the analytical measurements. End-exhaled air is sampled using valveless gas sampling tubes made of glass. Gaseous analytes are transferred to a liquid phase using a microscale solvent extraction performed directly inside the gas sampling tubes. The liquid extracts are analysed using a gas chromatograph equipped, as usual, with a liquid autosampler, and liquid standards are used for calibration. For demonstration purposes, the method's concept was applied to the determination of tetrachloroethene in end-exhaled air, which is a biomarker for occupational tetrachloroethene exposure. The method's performance was investigated in the concentration range 2 to 20 μg tetrachloroethene/L, which corresponds to today's exposure levels. The calibration curve was linear, and the intra-assay repeatability and recovery rate were sufficient. Analysis of real samples from dry-cleaning workers occupationally exposed to tetrachloroethene and from nonexposed subjects demonstrated the method's utility. In the case of tetrachloroethene, the method can be deployed quickly, requires no previous experiences in gas analysis, provides sufficient analytical reliability, and addresses typical end-exhaled air concentrations from exposed workers. PMID:24772171

  18. Characterizing lentic freshwater fish assemblages using multiple sampling methods

    USGS Publications Warehouse

    Fischer, Jesse R.; Quist, Michael

    2014-01-01

    Characterizing fish assemblages in lentic ecosystems is difficult, and multiple sampling methods are almost always necessary to gain reliable estimates of indices such as species richness. However, most research focused on lentic fish sampling methodology has targeted recreationally important species, and little to no information is available regarding the influence of multiple methods and timing (i.e., temporal variation) on characterizing entire fish assemblages. Therefore, six lakes and impoundments (48–1,557 ha surface area) were sampled seasonally with seven gear types to evaluate the combined influence of sampling methods and timing on the number of species and individuals sampled. Probabilities of detection for species indicated strong selectivities and seasonal trends that provide guidance on optimal seasons to use gears when targeting multiple species. The evaluation of species richness and number of individuals sampled using multiple gear combinations demonstrated that appreciable benefits over relatively few gears (e.g., to four) used in optimal seasons were not present. Specifically, over 90 % of the species encountered with all gear types and season combinations (N = 19) from six lakes and reservoirs were sampled with nighttime boat electrofishing in the fall and benthic trawling, modified-fyke, and mini-fyke netting during the summer. Our results indicated that the characterization of lentic fish assemblages was highly influenced by the selection of sampling gears and seasons, but did not appear to be influenced by waterbody type (i.e., natural lake, impoundment). The standardization of data collected with multiple methods and seasons to account for bias is imperative to monitoring of lentic ecosystems and will provide researchers with increased reliability in their interpretations and decisions made using information on lentic fish assemblages.

  19. An economic passive sampling method to detect particulate pollutants using magnetic measurements.

    PubMed

    Cao, Liwan; Appel, Erwin; Hu, Shouyun; Ma, Mingming

    2015-10-01

    Identifying particulate matter (PM) emitted from industrial processes into the atmosphere is an important issue in environmental research. This paper presents a passive sampling method using simple artificial samplers that maintains the advantage of bio-monitoring, but overcomes some of its disadvantages. The samplers were tested in a heavily polluted area (Linfen, China) and compared to results from leaf samples. Spatial variations of magnetic susceptibility from artificial passive samplers and leaf samples show very similar patterns. Scanning electron microscopy suggests that the collected PM are mostly in the range of 2-25 μm; frequent occurrence of spherical shape indicates industrial combustion dominates PM emission. Magnetic properties around power plants show different features than other plants. This sampling method provides a suitable and economic tool for semi-quantifying temporal and spatial distribution of air quality; they can be installed in a regular grid and calibrate the weight of PM.

  20. Comparison of pigment content of paint samples using spectrometric methods.

    PubMed

    Trzcińska, Beata; Kowalski, Rafał; Zięba-Palus, Janina

    2014-09-15

    The aim of the paper was to evaluate the influence of pigment concentration and its distribution in polymer binder on the possibility of colour identification and paint sample comparison. Two sets of paint samples: one containing red and another one green pigment were prepared. Each set consisted of 13 samples differing gradually in the concentration of pigment. To obtain the sets of various colour shades white paint was mixed with the appropriate pigment in the form of a concentrated suspension. After solvents evaporation the samples were examined using spectrometric methods. The resin and main filler were identified by IR method. Colour and white pigments were identified on the base of Raman spectra. Colour of samples were compared based on Vis spectrometry according to colour theory. It was found that samples are homogenous (parameter measuring colour similarity ΔE<3). The values of ΔE between the neighbouring samples in the set revealed decreasing linear function and between the first and following one--a logarithmic function.

  1. Off-axis angular spectrum method with variable sampling interval

    NASA Astrophysics Data System (ADS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Pi, Jae-Eun; Choi, Ji-Hun; Kim, Gi Heon; Lee, Myung-Lae; Ryu, Hojun; Hwang, Chi-Sun

    2015-08-01

    We proposed a novel off-axis angular spectrum method (ASM) for simulating free space wave propagation with a large shifted destination plane. The off-axis numerical simulation took wave propagation between a parallel source and a destination plane, but a destination plane was shifted from a source plane. The shifted angular spectrum method was proposed for diffraction simulation with a shifted destination plane and satisfied the Nyquist condition for sampling by limiting a bandwidth of a propagation field to avoid an aliasing error due to under sampling. However, the effective sampling number of the shifted ASM decreased when the shifted distance of the destination plane was large which caused a numerical error in the diffraction simulation. To compensate for the decrease of an effective sampling number for the large shifted destination plane, we used a variable sampling interval in a Fourier space to maintain the same effective sampling number independent of the shifted distance of the destination plane. As a result, our proposed off-axis ASM with a variable sampling interval can produce simulation results with high accuracy for nearly every shifted distance of a destination plane when an off-axis angle is less than 75°. We compared the performances of the off-axis ASM using the Chirp Z transform and non-uniform FFT for implementing a variable spatial frequency in a Fourier space.

  2. Comparison of pigment content of paint samples using spectrometric methods

    NASA Astrophysics Data System (ADS)

    Trzcińska, Beata; Kowalski, Rafał; Zięba-Palus, Janina

    2014-09-01

    The aim of the paper was to evaluate the influence of pigment concentration and its distribution in polymer binder on the possibility of colour identification and paint sample comparison. Two sets of paint samples: one containing red and another one green pigment were prepared. Each set consisted of 13 samples differing gradually in the concentration of pigment. To obtain the sets of various colour shades white paint was mixed with the appropriate pigment in the form of a concentrated suspension. After solvents evaporation the samples were examined using spectrometric methods. The resin and main filler were identified by IR method. Colour and white pigments were identified on the base of Raman spectra. Colour of samples were compared based on Vis spectrometry according to colour theory. It was found that samples are homogenous (parameter measuring colour similarity ΔE < 3). The values of ΔE between the neighbouring samples in the set revealed decreasing linear function and between the first and following one - a logarithmic function.

  3. [Progress in sample preparation and analytical methods for trace polar small molecules in complex samples].

    PubMed

    Zhang, Qianchun; Luo, Xialin; Li, Gongke; Xiao, Xiaohua

    2015-09-01

    Small polar molecules such as nucleosides, amines, amino acids are important analytes in biological, food, environmental, and other fields. It is necessary to develop efficient sample preparation and sensitive analytical methods for rapid analysis of these polar small molecules in complex matrices. Some typical materials in sample preparation, including silica, polymer, carbon, boric acid and so on, are introduced in this paper. Meanwhile, the applications and developments of analytical methods of polar small molecules, such as reversed-phase liquid chromatography, hydrophilic interaction chromatography, etc., are also reviewed. PMID:26753274

  4. RAPID METHOD FOR DETERMINATION OF RADIOSTRONTIUM IN EMERGENCY MILK SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-07-17

    A new rapid separation method for radiostrontium in emergency milk samples was developed at the Savannah River Site (SRS) Environmental Bioassay Laboratory (Aiken, SC, USA) that will allow rapid separation and measurement of Sr-90 within 8 hours. The new method uses calcium phosphate precipitation, nitric acid dissolution of the precipitate to coagulate residual fat/proteins and a rapid strontium separation using Sr Resin (Eichrom Technologies, Darien, IL, USA) with vacuum-assisted flow rates. The method is much faster than previous method that use calcination or cation exchange pretreatment, has excellent chemical recovery, and effectively removes beta interferences. When a 100 ml sample aliquot is used, the method has a detection limit of 0.5 Bq/L, well below generic emergency action levels.

  5. Pattern recognition methods and air pollution source identification. [based on wind direction

    NASA Technical Reports Server (NTRS)

    Leibecki, H. F.; King, R. B.

    1978-01-01

    Directional air samplers, used for resolving suspended particulate matter on the basis of time and wind direction were used to assess the feasibility of characterizing and identifying emission source types in urban multisource environments. Filters were evaluated for 16 elements and X-ray fluorescence methods yielded elemental concentrations for direction, day, and the interaction of direction and day. Large numbers of samples are necessary to compensate for large day-to-day variations caused by wind perturbations and/or source changes.

  6. Residues of 2, 4-D in air samples from Saskatchewan: 1966-1975.

    PubMed

    Grover, R; Kerr, L A; Wallace, K; Yoshida, K; Maybank, J

    1976-01-01

    Residues of 2,4-D (2,4-dichlorophenoxyacetic acid) in air samples from several sampling sites in central and southern Saskatchewan during the spraying seasons in the 1966-68 and 1970-75 periods were determined by gas-liquid chromatographic techniques. Initially, individual esters of 2,4-D were characterized by retention times and confirmed further by co-injection and dual column procedures. Since 1973, however, only total 2,4-D acid levels in air samples have been determined after esterification to the methyl ester and confirmed by gc/ms techniques whenever possible. Up to 50% of the daily samples collected during the spraying season at any of the locations and during any given year contained 2,4-D, with butyl esters being found most frequently. The daily 24-hr mean atmospheric concentrations of 2,4-D ranged from 0.01 to 1.22 mug/m3, 0.01 to 13.50 mug/m3, and 0.05 to 0.59 mug/m3 for the iso-propyl, mixed butyl and iso-octyl esters, respectively. Even when the samples were analysed for the total 2,4-D content, i.e. from 1973 onwards, the maximum level of the total acid reached only 23.14 mug/m3. In any given year and at any of the sampling sites, about 30% of the samples contained less than 0.01 mug/m3 of 2,4-D. In another 40% of the samples, the levels of 2,4-D ranged from 0.01 to 0.099 mug/m3. Only about 30% of the samples contained 2,4-D concentrations higher than 0.1 mug/m3, with only 10% or less exceeding 1 mug/m3. None of the samples, obtained with the high volume particulate sampler, showed any detectable levels of 2,4-D, indicating little or no transport of 2,4-D adsorbed on dust particles or as crystals of amine salts. PMID:1002953

  7. A method to estimate spatiotemporal air quality in an urban traffic corridor.

    PubMed

    Singh, Nongthombam Premananda; Gokhale, Sharad

    2015-12-15

    Air quality exposure assessment using personal exposure sampling or direct measurement of spatiotemporal air pollutant concentrations has difficulty and limitations. Most statistical methods used for estimating spatiotemporal air quality do not account for the source characteristics (e.g. emissions). In this study, a prediction method, based on the lognormal probability distribution of hourly-average-spatial concentrations of carbon monoxide (CO) obtained by a CALINE4 model, has been developed and validated in an urban traffic corridor. The data on CO concentrations were collected at three locations and traffic and meteorology within the urban traffic corridor.(1) The method has been developed with the data of one location and validated at other two locations. The method estimated the CO concentrations reasonably well (correlation coefficient, r≥0.96). Later, the method has been applied to estimate the probability of occurrence [P(C≥Cstd] of the spatial CO concentrations in the corridor. The results have been promising and, therefore, may be useful to quantifying spatiotemporal air quality within an urban area. PMID:26318683

  8. A method to estimate spatiotemporal air quality in an urban traffic corridor.

    PubMed

    Singh, Nongthombam Premananda; Gokhale, Sharad

    2015-12-15

    Air quality exposure assessment using personal exposure sampling or direct measurement of spatiotemporal air pollutant concentrations has difficulty and limitations. Most statistical methods used for estimating spatiotemporal air quality do not account for the source characteristics (e.g. emissions). In this study, a prediction method, based on the lognormal probability distribution of hourly-average-spatial concentrations of carbon monoxide (CO) obtained by a CALINE4 model, has been developed and validated in an urban traffic corridor. The data on CO concentrations were collected at three locations and traffic and meteorology within the urban traffic corridor.(1) The method has been developed with the data of one location and validated at other two locations. The method estimated the CO concentrations reasonably well (correlation coefficient, r≥0.96). Later, the method has been applied to estimate the probability of occurrence [P(C≥Cstd] of the spatial CO concentrations in the corridor. The results have been promising and, therefore, may be useful to quantifying spatiotemporal air quality within an urban area.

  9. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    SciTech Connect

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides and strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.

  10. On the Exploitation of Sensitivity Derivatives for Improving Sampling Methods

    NASA Technical Reports Server (NTRS)

    Cao, Yanzhao; Hussaini, M. Yousuff; Zang, Thomas A.

    2003-01-01

    Many application codes, such as finite-element structural analyses and computational fluid dynamics codes, are capable of producing many sensitivity derivatives at a small fraction of the cost of the underlying analysis. This paper describes a simple variance reduction method that exploits such inexpensive sensitivity derivatives to increase the accuracy of sampling methods. Three examples, including a finite-element structural analysis of an aircraft wing, are provided that illustrate an order of magnitude improvement in accuracy for both Monte Carlo and stratified sampling schemes.

  11. A survey of recent results in passive sampling of water and air by semipermeable membrane devices

    USGS Publications Warehouse

    Prest, Harry F.; Huckins, James N.; Petty, Jimmie D.; Herve, Sirpa; Paasivirta, Jaakko; Heinonen, Pertti

    1995-01-01

    A survey is presented of some recent results for passive sampling of water and air for trace organic contaminants using lipid-filled semipermeable membrane devices (SPMDs). Results of water sampling for trace organochlorine compounds using simultaneously exposed SPMDs and the most universally applied biomonitor (bivalves) are discussed. In general, the total amounts of accumulated analytes available for analysis in bivalves and SPMDs were comparable. However, SPMD controls typically had negligible levels of contamination, which was not always the case for transplanted bivalves, even after prolonged depuration prior to exposure. In surveys of the spatial trends of organochlorines at a series of sites, data from bivalves and SPMDs provided the same picture of contaminant distribution and severity. An exception was ionizable contaminants such as the chlorinated phenolic compounds and their transformation products found in pulp mill effluents. In these cases the two monitoring approaches compliment each other, i.e. what is not found in bivalves appears in SPMDs and vice versa. SPMDs have also been applied in environments where biomonitoring is not feasible. SPMDs have shown their utility in studies of trace levels of polyaromatic hydrocarbons by locating and characterizing point sources. An example is given of their application to the calculation of contaminant half-lives from aqueous SPMD residues, a direct measurement of the persistence of contaminants in an environmental compartment. Similarly, results of air sampling with SPMDs in a relatively pristine coastal location are cited which reveal a tremendous enhancement in p,p′-DDE relative to open ocean values.

  12. RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-08-27

    The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared to NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.

  13. Exposure to airborne allergens: a review of sampling methods.

    PubMed

    Renström, Anne

    2002-10-01

    A number of methods are used to assess exposure to high-molecular weight allergens. In the occupational setting, airborne dust is often collected on filters using pumps, the filters are eluted and allergen content in the eluate analysed using immunoassays. Collecting inhalable dust using person-carried pumps may be considered the gold standard. Other allergen sampling methods are available. Recently, a method that collects nasally inhaled dust on adhesive surfaces within nasal samplers has been developed. Allergen content can be analysed in eluates using sensitive enzyme immunoassays, or allergen-bearing particles can be immunostained using antibodies, and studied under the microscope. Settling airborne dust can be collected in petri dishes, a cheap and simple method that has been utilised in large-scale exposure studies. Collection of reservoir dust from surfaces using vacuum cleaners with a dust collector is commonly used to measure pet or mite allergens in homes. The sampling methods differ in properties and relevance to personal allergen exposure. Since methods for all steps from sampling to analysis differ between laboratories, determining occupational exposure limits for protein allergens is today unfeasible. A general standardisation of methods is needed.

  14. Performance Prediction Method of CO2 Cycle for Air Cooling

    NASA Astrophysics Data System (ADS)

    Koyama, Shigeru; Xue, Jun; Kuwahara, Ken

    From the perspective of global environmental protection and energy-saving, the research and development on high-efficiency heat pump and refrigeration systems using environment-friendly refrigerants have become one of the most important issues in the air-conditioning and refrigeration sector. In the present work, a steady-state model of the CO2 transcritical cycle for air cooling, which consists of a rotary compressor, a fin-tube gas cooler,a fin-tube evaporator and an expansion valve, has been developed. The detailed model of fin-tube heat exchanger has been constructed by means of the finite volume method, in which the local heat transfer and flow characteristics are evaluated. It should be noted that the effects of the dew condensation generated on the cooling surface are considered in the evaporator model. As a calculation example, the effects of the indoor air wet-bulb temperature on the cycle performance have been examined with this developed simulator.

  15. Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters

    PubMed Central

    Calfee, M. Worth; Rose, Laura J.; Tufts, Jenia; Morse, Stephen; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2016-01-01

    The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37 mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50% of their total holding capacity. The results were analyzed by one-way ANOVA across material types, presence or absence of dust, and sampling device. The extraction method gave higher relative recoveries than the two vacuum methods evaluated (p ≤ 0.001). On average, recoveries obtained by the vacuum methods were about 30% of those achieved by the extraction method. Relative recoveries between the two vacuum methods were not significantly different (p > 0.05). Although extraction methods yielded higher recoveries than vacuum methods, either HVAC filter sampling approach may provide a rapid and inexpensive mechanism for understanding the extent of contamination following a wide-area biological release incident. PMID:24184312

  16. Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters.

    PubMed

    Calfee, M Worth; Rose, Laura J; Tufts, Jenia; Morse, Stephen; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2014-01-01

    The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50% of their total holding capacity. The results were analyzed by one-way ANOVA across material types, presence or absence of dust, and sampling device. The extraction method gave higher relative recoveries than the two vacuum methods evaluated (p≤0.001). On average, recoveries obtained by the vacuum methods were about 30% of those achieved by the extraction method. Relative recoveries between the two vacuum methods were not significantly different (p>0.05). Although extraction methods yielded higher recoveries than vacuum methods, either HVAC filter sampling approach may provide a rapid and inexpensive mechanism for understanding the extent of contamination following a wide-area biological release incident. PMID:24184312

  17. Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters.

    PubMed

    Calfee, M Worth; Rose, Laura J; Tufts, Jenia; Morse, Stephen; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2014-01-01

    The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50% of their total holding capacity. The results were analyzed by one-way ANOVA across material types, presence or absence of dust, and sampling device. The extraction method gave higher relative recoveries than the two vacuum methods evaluated (p≤0.001). On average, recoveries obtained by the vacuum methods were about 30% of those achieved by the extraction method. Relative recoveries between the two vacuum methods were not significantly different (p>0.05). Although extraction methods yielded higher recoveries than vacuum methods, either HVAC filter sampling approach may provide a rapid and inexpensive mechanism for understanding the extent of contamination following a wide-area biological release incident.

  18. Recent developments in the analysis of air samples by luminescence techniques

    SciTech Connect

    Vo-Dinh, T.

    1981-01-01

    A report is presented on recent developments in luminescence analysis of atmospheric samples using two simple luminescence methods, the synchronous excitation and the room temperature phosphorescence (RPT) techniques. Samples extracted from high-volume samplers can be analyzed for their content of certain polynuclear aromatic (PNA) compounds using these two spectroscopic methods. The RPT technique also provides a novel approach for direct detection of PNA vapors collected on filter paper.

  19. Development and application of a method for analyzing trifluoroacetic acid in environmental samples

    SciTech Connect

    Zehavi, D.; Seiber, J.N.; Wujcik, C.

    1995-12-01

    Trifluoroacetic acid (TFA) is a stable end-product from the oxidative degradation of halocarbon refrigerants proposed for replacement of chlorofluorocarbons. The potential accumulation of TFA in the environment is of concern as halocarbons such as HCFC-123 (CCl{sub 2}HCF{sub 3}), HCFC-124 (CClHFCF{sub 3}) and HFC-134a (CF{sub 3}CFH{sub 2}) become more widely used. We developed a method for analyzing TFA in air, atmospheric water, and surface water, based upon (1) methylation of TFA with dimethylsulfate in sulfuric acid and (2) head-space gas chromatographic determination of TFA as its methyl ester using electron capture or mass selective detection. TFA levels at 50 ppt or less may be detected in water subjected to evaporative concentration, and at 1 ng/m{sup 3} or less in air sampled through a glycerine-bicarbonate denuder. Results from analyses of samples from Nevada and California will be presented.

  20. Monitoring organic nitrogen species in the UT/LS - a new system for analysis of CARIBIC whole air samples

    NASA Astrophysics Data System (ADS)

    Sauvage, Carina; Thorenz, Ute; Baker, Angela; Brenninkmeijer, Carl; Williams, Jonathan

    2014-05-01

    The CARIBIC project is a unique program for long term and global scale monitoring of the atmosphere (http://www.caribic-atmospheric.com). An instrument container is installed monthly into a civil aircraft operated by Lufthansa (Airbus A 340-600) and makes atmospheric observations en route from Frankfurt, Germany to various destinations around the globe. In four to six long distance flights at a cruising altitude of 10 to 12 km online measurements of various atmospheric tracers are performed during the flight as well as whole air samples are taken with two different sampling units (116 samples in both glass and stainless steel canisters). These samples are routinely analyzed for greenhouse gases, non-methane hydrocarbons (NMHC) and halogenated compounds. Nitrogen containing compounds play various important roles in the atmosphere. Alkyl nitrates (RONO2) are products of the reaction of NMHC with OH and other oxidants in the presence of NO. They can provide information on the oxidative history of an air mass. Moreover they influence photolchemical ozone formation and act as a transport mechanism for reactive nitrogen. Less reactive nitrogen containing species such as HCN and acetonitrile are important markers for biomass burning, while organic amines are involved in gas to particle partitioning. Finally N2O is a long lived nitrogen containing gas important for the Earth's radiative budget. Regular measurements of such nitrogen compounds would therefore be a significant contribution to the CARIBIC data set. Especially for high altitude samples, in which the mixing ratios of many species are expected to be in the low ppt range, a highly sensitive method for analysis is required. Therefore a new system for measurement of nitrogen compounds has been built up, comprising a gas chromatograph (GC) using a nitrogen chemiluminescence detector (NCD). An important advantage of the NCD is that it is selective for nitrogen and equimolar. The nitrogen compounds are sequentially pre

  1. A Model Using Local Weather Data to Determine the Effective Sampling Volume for PCB Congeners Collected on Passive Air Samplers.

    PubMed

    Herkert, Nicholas J; Martinez, Andres; Hornbuckle, Keri C

    2016-07-01

    We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF-PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, predicts the Veff as a function of physical-chemical properties of each compound and meteorology from the closest Integrated Surface Database (ISD) data set obtained through NOAA's National Centers for Environmental Information (NCEI). The model was developed to be user-friendly, only requiring basic Matlab knowledge. To illustrate the effectiveness of the model, we evaluated three independent data sets of airborne PCBs simultaneously collected using passive and active samplers: at sites in Chicago, Lancaster, UK, and Toronto, Canada. The model provides Veff values comparable to those using depuration compounds and calibration against active samplers, yielding an average congener specific concentration method ratio (active/passive) of 1.1 ± 1.2. We applied the model to PUF-PAS samples collected in Chicago and show that previous methods can underestimate concentrations of PCBs by up to 40%, especially for long deployments, deployments conducted under warming conditions, and compounds with log Koa values less than 8.

  2. A Model Using Local Weather Data to Determine the Effective Sampling Volume for PCB Congeners Collected on Passive Air Samplers.

    PubMed

    Herkert, Nicholas J; Martinez, Andres; Hornbuckle, Keri C

    2016-07-01

    We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF-PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, predicts the Veff as a function of physical-chemical properties of each compound and meteorology from the closest Integrated Surface Database (ISD) data set obtained through NOAA's National Centers for Environmental Information (NCEI). The model was developed to be user-friendly, only requiring basic Matlab knowledge. To illustrate the effectiveness of the model, we evaluated three independent data sets of airborne PCBs simultaneously collected using passive and active samplers: at sites in Chicago, Lancaster, UK, and Toronto, Canada. The model provides Veff values comparable to those using depuration compounds and calibration against active samplers, yielding an average congener specific concentration method ratio (active/passive) of 1.1 ± 1.2. We applied the model to PUF-PAS samples collected in Chicago and show that previous methods can underestimate concentrations of PCBs by up to 40%, especially for long deployments, deployments conducted under warming conditions, and compounds with log Koa values less than 8. PMID:26963482

  3. A Model Using Local Weather Data to Determine the Effective Sampling Volume for PCB Congeners Collected on Passive Air Samplers

    PubMed Central

    2016-01-01

    We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF–PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, predicts the Veff as a function of physical-chemical properties of each compound and meteorology from the closest Integrated Surface Database (ISD) data set obtained through NOAA’s National Centers for Environmental Information (NCEI). The model was developed to be user-friendly, only requiring basic Matlab knowledge. To illustrate the effectiveness of the model, we evaluated three independent data sets of airborne PCBs simultaneously collected using passive and active samplers: at sites in Chicago, Lancaster, UK, and Toronto, Canada. The model provides Veff values comparable to those using depuration compounds and calibration against active samplers, yielding an average congener specific concentration method ratio (active/passive) of 1.1 ± 1.2. We applied the model to PUF–PAS samples collected in Chicago and show that previous methods can underestimate concentrations of PCBs by up to 40%, especially for long deployments, deployments conducted under warming conditions, and compounds with log Koa values less than 8. PMID:26963482

  4. Sampling methods for monitoring changes in gonococcal populations.

    PubMed Central

    Bindayna, K. M.; Ison, C. A.

    1989-01-01

    A total of 160 consecutive isolates of Neisseria gonorrhoeae was collected over a 3-month period. They were tested for their susceptibility to penicillin, erythromycin and spectinomycin and the auxotype and the serotype determined. We have evaluated two sampling methods, the collection of every fifth isolate and the first 20 isolates (10 male and 10 female) each month, to determine whether either is representative of the total population. There was no significant difference between either method of sampling and the total for detecting the predominant auxotypes and serovars or the distributions in antibiotic susceptibility. It is possible to monitor major changes in a gonococcal population, particularly susceptibility to antibiotics, using a sample of the total population. PMID:2528473

  5. A New GP Recombination Method Using Random Tree Sampling

    NASA Astrophysics Data System (ADS)

    Tanji, Makoto; Iba, Hitoshi

    We propose a new program evolution method named PORTS (Program Optimization by Random Tree Sampling) which is motivated by the idea of preservation and control of tree fragments in GP (Genetic Programming). We assume that to recombine genetic materials efficiently, tree fragments of any size should be preserved into the next generation. PORTS samples tree fragments and concatenates them by traversing and transitioning between promising trees instead of using subtree crossover and mutation. Because the size of a fragment preserved during a generation update follows a geometric distribution, merits of the method are that it is relatively easy to predict the behavior of tree fragments over time and to control sampling size, by changing a single parameter. From experimental results on RoyalTree, Symbolic Regression and 6-Multiplexer problem, we observed that the performance of PORTS is competitive with Simple GP. Furthermore, the average node size of optimal solutions obtained by PORTS was simple than Simple GP's result.

  6. Review of sampling and analysis methodology for polynuclear aromatic compounds in air from mobile sources. Final report, 1 March-30 November 1983

    SciTech Connect

    Chuang, C.C.; Petersen, B.A.

    1985-06-01

    The objective of the program was to review and recommend test compounds and sampling and analysis methods for a future EPA study of polynuclear aromatic hydrocarbons (PAH) in microenvironments. Review of PAH profiles in ambient air indicated that concentrations of PAH were generally higher in winter than summer and varied with climate and between sampling sites within an urban area. Levels of several PAH were found to be proportional to traffic density. Studies of the biological activity of ambient air samples showed that some PAH and their nitrated derivatives are extremely carcinogenic and mutagenic. The following compounds were determined to be the most prevalent and mutagenic in ambient air and were recommended for the future EPA study: phenanthrene, pyrene, cyclopenta(c,d)pyrene, benzo(a)pyrene, dibenz(a,h)anthracene, 1-nitropyrene, fluoranthene, benz(a)anthracene, benzo(e)pyrene, benzo(g,h,i)perylene, coronene, and 3-nitrofluoranthene. In the review of PAH sampling methods, collection of both gaseous and particulate bound PAH was determined to be necessary to accurately characterize health effects of PAH in ambient air. Most studies have used filters to sample particulate-bound PAH and absorbents to collect vapor phase PAH. The major sampling problems encountered in the studies were PAH losses due to volatilization and reactivity.

  7. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Rubino, M.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2012-07-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change must have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological changes in the CFC production process over the last 80 yr. Propagating the mass-balance calculations into the future demonstrates that as emissions decrease to zero, isotopic fractionation by the stratospheric sinks will lead to continued 13C enrichment in atmospheric CFC-12.

  8. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2013-01-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change is likely to have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological advances in the CFC production process over the last 80 yr, though direct evidence is lacking.

  9. Sampling and measurement issues in establishing a climate reference upper air network

    NASA Astrophysics Data System (ADS)

    Gardiner, T.; Madonna, F.; Wang, J.; Whiteman, D. N.; Dykema, J.; Fassò, A.; Thorne, P. W.; Bodeker, G.

    2013-09-01

    The GCOS Reference Upper Air Network (GRUAN) is an international reference observing network, designed to meet climate requirements and to fill a major void in the current global observing system. Upper air observations within the GRUAN network will provide long-term high-quality climate records, will be used to constrain and validate data from space based remote sensors, and will provide accurate data for the study of atmospheric processes. The network covers measurements of a range of key climate variables including temperature. Implementation of the network has started, and as part of this process a number of scientific questions need to be addressed in order to establish a viable climate reference upper air network, in addition to meeting the other objectives for the network measurements. These include quantifying collocation issues for different measurement techniques including the impact on the overall uncertainty of combined measurements; change management requirements when switching between sensors; assessing the benefit of complementary measurements of the same variable using different measurement techniques; and establishing the appropriate sampling strategy to determine long-term trends. This paper reviews the work that is currently underway to address these issues.

  10. Development of an automated data processing method for sample to sample comparison of seized methamphetamines.

    PubMed

    Choe, Sanggil; Lee, Jaesin; Choi, Hyeyoung; Park, Yujin; Lee, Heesang; Pyo, Jaesung; Jo, Jiyeong; Park, Yonghoon; Choi, Hwakyung; Kim, Suncheun

    2012-11-30

    The information about the sources of supply, trafficking routes, distribution patterns and conspiracy links can be obtained from methamphetamine profiling. The precursor and synthetic method for the clandestine manufacture can be estimated from the analysis of minor impurities contained in methamphetamine. Also, the similarity between samples can be evaluated using the peaks that appear in chromatograms. In South Korea, methamphetamine was the most popular drug but the total seized amount of methamphetamine whole through the country was very small. Therefore, it would be more important to find the links between samples than the other uses of methamphetamine profiling. Many Asian countries including Japan and South Korea have been using the method developed by National Research Institute of Police Science of Japan. The method used gas chromatography-flame ionization detector (GC-FID), DB-5 column and four internal standards. It was developed to increase the amount of impurities and minimize the amount of methamphetamine. After GC-FID analysis, the raw data have to be processed. The data processing steps are very complex and require a lot of time and effort. In this study, Microsoft Visual Basic Application (VBA) modules were developed to handle these data processing steps. This module collected the results from the data into an Excel file and then corrected the retention time shift and response deviation generated from the sample preparation and instruments analysis. The developed modules were tested for their performance using 10 samples from 5 different cases. The processed results were analyzed with Pearson correlation coefficient for similarity assessment and the correlation coefficient of the two samples from the same case was more than 0.99. When the modules were applied to 131 seized methamphetamine samples, four samples from two different cases were found to have the common origin and the chromatograms of the four samples were appeared visually identical

  11. Development of an automated data processing method for sample to sample comparison of seized methamphetamines.

    PubMed

    Choe, Sanggil; Lee, Jaesin; Choi, Hyeyoung; Park, Yujin; Lee, Heesang; Pyo, Jaesung; Jo, Jiyeong; Park, Yonghoon; Choi, Hwakyung; Kim, Suncheun

    2012-11-30

    The information about the sources of supply, trafficking routes, distribution patterns and conspiracy links can be obtained from methamphetamine profiling. The precursor and synthetic method for the clandestine manufacture can be estimated from the analysis of minor impurities contained in methamphetamine. Also, the similarity between samples can be evaluated using the peaks that appear in chromatograms. In South Korea, methamphetamine was the most popular drug but the total seized amount of methamphetamine whole through the country was very small. Therefore, it would be more important to find the links between samples than the other uses of methamphetamine profiling. Many Asian countries including Japan and South Korea have been using the method developed by National Research Institute of Police Science of Japan. The method used gas chromatography-flame ionization detector (GC-FID), DB-5 column and four internal standards. It was developed to increase the amount of impurities and minimize the amount of methamphetamine. After GC-FID analysis, the raw data have to be processed. The data processing steps are very complex and require a lot of time and effort. In this study, Microsoft Visual Basic Application (VBA) modules were developed to handle these data processing steps. This module collected the results from the data into an Excel file and then corrected the retention time shift and response deviation generated from the sample preparation and instruments analysis. The developed modules were tested for their performance using 10 samples from 5 different cases. The processed results were analyzed with Pearson correlation coefficient for similarity assessment and the correlation coefficient of the two samples from the same case was more than 0.99. When the modules were applied to 131 seized methamphetamine samples, four samples from two different cases were found to have the common origin and the chromatograms of the four samples were appeared visually identical

  12. A General Linear Method for Equating with Small Samples

    ERIC Educational Resources Information Center

    Albano, Anthony D.

    2015-01-01

    Research on equating with small samples has shown that methods with stronger assumptions and fewer statistical estimates can lead to decreased error in the estimated equating function. This article introduces a new approach to linear observed-score equating, one which provides flexible control over how form difficulty is assumed versus estimated…

  13. Periodicity detection method for small-sample time series datasets.

    PubMed

    Tominaga, Daisuke

    2010-01-01

    Time series of gene expression often exhibit periodic behavior under the influence of multiple signal pathways, and are represented by a model that incorporates multiple harmonics and noise. Most of these data, which are observed using DNA microarrays, consist of few sampling points in time, but most periodicity detection methods require a relatively large number of sampling points. We have previously developed a detection algorithm based on the discrete Fourier transform and Akaike's information criterion. Here we demonstrate the performance of the algorithm for small-sample time series data through a comparison with conventional and newly proposed periodicity detection methods based on a statistical analysis of the power of harmonics.We show that this method has higher sensitivity for data consisting of multiple harmonics, and is more robust against noise than other methods. Although "combinatorial explosion" occurs for large datasets, the computational time is not a problem for small-sample datasets. The MATLAB/GNU Octave script of the algorithm is available on the author's web site: http://www.cbrc.jp/%7Etominaga/piccolo/. PMID:21151841

  14. Venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Young, Douglas C.; Wade, Larry O.; Burney, Lewis G.

    1992-01-01

    Documentation of the installation and use of venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms is presented. Information on the types of venturis that are useful for meeting the pumping requirements of atmospheric-sampling experiments is also presented. A description of the configuration and installation of the venturi system vacuum line is included with details on the modifications that were made to adapt a venturi to the NASA Electra aircraft at GSFC, Wallops Flight Facility. Flight test results are given for several venturis with emphasis on applications to the Differential Absorption Carbon Monoxide Measurement (DACOM) system at LaRC. This is a source document for atmospheric scientists interested in using the venturi systems installed on the NASA Electra or adapting the technology to other aircraft.

  15. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  16. A new method of measuring {sup 81}Kr and {sup 85}Kr abundances in environmental samples.

    SciTech Connect

    Du, X.; Bailey, K.; Lu, Z.-T.; Mueller, P.; O'Connor, T. P.; Young, L.; Purtschert, R.; Lehmann, B. E.; Lorenzo, R.; Sturchio, N. C.; Northwestern Univ.; Univ. of Bern; Univ. of Illinois-Chicago

    2003-10-29

    We demonstrate a new method for determining the {sup 81}Kr/Kr ratio in environmental samples based upon two measurements: the {sup 85}Kr/{sup 81}Kr ratio measured by Atom Trap Trace Analysis (ATTA) and the {sup 85}Kr/Kr ratio measured by Low-Level Counting (LLC). This method can be used to determine the mean residence time of groundwater in the range of 10{sup 5}--10{sup 6} a. It requires a sample of 100 {mu}l STP of Kr extracted from approximately two tons of water. With modern atmospheric Kr samples, we demonstrate that the ratios measured by ATTA and LLC are directly proportional to each other within the measurement error of {+-}10%; we calibrate the {sup 81}Kr/Kr ratio of modern air measured using this method; and we show that the {sup 81}Kr/Kr ratios of samples extracted from air before and after the development of the nuclear industry are identical within the measurement error.

  17. Evaluation of physical sampling efficiency for cyclone-based personal bioaerosol samplers in moving air environments.

    PubMed

    Su, Wei-Chung; Tolchinsky, Alexander D; Chen, Bean T; Sigaev, Vladimir I; Cheng, Yung Sung

    2012-09-01

    The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.

  18. Comparison of DNA preservation methods for environmental bacterial community samples

    USGS Publications Warehouse

    Gray, Michael A.; Pratte, Zoe A.; Kellogg, Christina A.

    2013-01-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard™, RNAlater®, DMSO–EDTA–salt (DESS), FTA® cards, and FTA Elute® cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA® cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard™, RNAlater®, and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost.

  19. Comparison of aquatic macroinvertebrate samples collected using different field methods

    USGS Publications Warehouse

    Lenz, Bernard N.; Miller, Michael A.

    1996-01-01

    Government agencies, academic institutions, and volunteer monitoring groups in the State of Wisconsin collect aquatic macroinvertebrate data to assess water quality. Sampling methods differ among agencies, reflecting the differences in the sampling objectives of each agency. Lack of infor- mation about data comparability impedes data shar- ing among agencies, which can result in duplicated sampling efforts or the underutilization of avail- able information. To address these concerns, com- parisons were made of macroinvertebrate samples collected from wadeable streams in Wisconsin by personnel from the U.S. Geological Survey- National Water Quality Assessment Program (USGS-NAWQA), the Wisconsin Department of Natural Resources (WDNR), the U.S. Department of Agriculture-Forest Service (USDA-FS), and volunteers from the Water Action Volunteer-Water Quality Monitoring Program (WAV). This project was part of the Intergovernmental Task Force on Monitoring Water Quality (ITFM) Wisconsin Water Resources Coordination Project. The numbers, types, and environmental tolerances of the organ- isms collected were analyzed to determine if the four different field methods that were used by the different agencies and volunteer groups provide comparable results. Additionally, this study com- pared the results of samples taken from different locations and habitats within the same streams.

  20. Gas-particle partitioning of PCDD/Fs in daily air samples

    NASA Astrophysics Data System (ADS)

    Lohmann, Rainer; Lee, Robert G. M.; Green, Nicholas J. L.; Jones, Kevin C.

    Eight short-term (24-48 h) air samples were taken at Lancaster, UK, to study the gas-particle partitioning of PCDD/Fs. Sampling dates in autumn 1997 were selected with a view to minimising temperature fluctuation during the sampling events. ΣCl 4-8DD/Fs ( ΣTEQ) for the first 6 samples were 1.1-3.6 pg m -3 (15-44 fg TEQ m -3), typical of a rural site; two other samples had ΣCl 4-8DD/Fs of 18 and 7.9 pg m -3, with 320 and 100 fg TEQ m -3. The observed gas-particle distributions varied from 0-34% particle-bound for Cl 2/3DD/Fs to >70% for Cl 6-8DD/Fs. Measured particle-bound fractions were compared to theoretical estimates of their distribution based on the Junge-Pankow model using three different reported sets of vapour pressures. The best correlation was obtained using vapour pressures derived from measured GC-retention time indices ( Eitzer and Hites, 1988). Plotting log partition coefficient ( Kp) versus log sub-cooled liquid vapour pressure ( pL) gave excellent correlations with slopes of roughly -1 for all homologue groups. 2, 3, 7, 8-substituted congeners showed slopes of -1 for the first five sampling events. It is proposed that kinetic factors at the low ambient temperatures, coupled with additional emissions during the last sampling events resulted in non-equilibrium partitioning.

  1. Evaluation of Environmental Sample Analysis Methods and Results Reporting in the National Children's Study Vanguard Study.

    PubMed

    Heikkinen, Maire S A; Khalaf, Abdisalam; Beard, Barbara; Viet, Susan M; Dellarco, Michael

    2016-05-01

    During the initial Vanguard phase of the U.S. National Children's Study (NCS), about 2000 tap water, surface wipe, and air samples were collected and analyzed immediately. The shipping conditions, analysis methods, results, and laboratory performance were evaluated to determine the best approaches for use in the NCS Main Study. The main conclusions were (1) to employ established sample analysis methods, when possible, and alternate methodologies only after careful consideration with method validation studies; (2) lot control and prescreening sample collection materials are important quality assurance procedures; (3) packing samples correctly requires careful training and adjustment of shipping conditions to local conditions; (4) trip blanks and spiked samples should be considered for samplers with short expiration times and labile analytes; (5) two study-specific results reports should be required: laboratory electronic data deliverables (EDD) of sample results in a useable electronic format (CSV or SEDD XML/CSV) and a data package with sample results and supporting information in PDF format. These experiences and lessons learned can be applied to any long-term study.

  2. A flexible importance sampling method for integrating subgrid processes

    NASA Astrophysics Data System (ADS)

    Raut, E. K.; Larson, V. E.

    2016-01-01

    Numerical models of weather and climate need to compute grid-box-averaged rates of physical processes such as microphysics. These averages are computed by integrating subgrid variability over a grid box. For this reason, an important aspect of atmospheric modeling is spatial integration over subgrid scales. The needed integrals can be estimated by Monte Carlo integration. Monte Carlo integration is simple and general but requires many evaluations of the physical process rate. To reduce the number of function evaluations, this paper describes a new, flexible method of importance sampling. It divides the domain of integration into eight categories, such as the portion that contains both precipitation and cloud, or the portion that contains precipitation but no cloud. It then allows the modeler to prescribe the density of sample points within each of the eight categories. The new method is incorporated into the Subgrid Importance Latin Hypercube Sampler (SILHS). The resulting method is tested on drizzling cumulus and stratocumulus cases. In the cumulus case, the sampling error can be considerably reduced by drawing more sample points from the region of rain evaporation.

  3. New Methods of Sample Preparation for Atom Probe Specimens

    NASA Technical Reports Server (NTRS)

    Kuhlman, Kimberly, R.; Kowalczyk, Robert S.; Ward, Jennifer R.; Wishard, James L.; Martens, Richard L.; Kelly, Thomas F.

    2003-01-01

    Magnetite is a common conductive mineral found on Earth and Mars. Disk-shaped precipitates approximately 40 nm in diameter have been shown to have manganese and aluminum concentrations. Atom-probe field-ion microscopy (APFIM) is the only technique that can potentially quantify the composition of these precipitates. APFIM will be used to characterize geological and planetary materials, analyze samples of interest for geomicrobiology; and, for the metrology of nanoscale instrumentation. Prior to APFIM sample preparation was conducted by electropolishing, the method of sharp shards (MSS), or Bosch process (deep reactive ion etching) with focused ion beam (FIB) milling as a final step. However, new methods are required for difficult samples. Many materials are not easily fabricated using electropolishing, MSS, or the Bosch process, FIB milling is slow and expensive, and wet chemistry and the reactive ion etching are typically limited to Si and other semiconductors. APFIM sample preparation using the dicing saw is commonly used to section semiconductor wafers into individual devices following manufacture. The dicing saw is a time-effective method for preparing high aspect ratio posts of poorly conducting materials. Femtosecond laser micromachining is also suitable for preparation of posts. FIB time required is reduced by about a factor of 10 and multi-tip specimens can easily be fabricated using the dicing saw.

  4. A flexible importance sampling method for integrating subgrid processes

    DOE PAGES

    Raut, E. K.; Larson, V. E.

    2016-01-29

    Numerical models of weather and climate need to compute grid-box-averaged rates of physical processes such as microphysics. These averages are computed by integrating subgrid variability over a grid box. For this reason, an important aspect of atmospheric modeling is spatial integration over subgrid scales. The needed integrals can be estimated by Monte Carlo integration. Monte Carlo integration is simple and general but requires many evaluations of the physical process rate. To reduce the number of function evaluations, this paper describes a new, flexible method of importance sampling. It divides the domain of integration into eight categories, such as the portion that containsmore » both precipitation and cloud, or the portion that contains precipitation but no cloud. It then allows the modeler to prescribe the density of sample points within each of the eight categories. The new method is incorporated into the Subgrid Importance Latin Hypercube Sampler (SILHS). The resulting method is tested on drizzling cumulus and stratocumulus cases. In the cumulus case, the sampling error can be considerably reduced by drawing more sample points from the region of rain evaporation.« less

  5. A method for sampling microbial aerosols using high altitude balloons.

    PubMed

    Bryan, N C; Stewart, M; Granger, D; Guzik, T G; Christner, B C

    2014-12-01

    Owing to the challenges posed to microbial aerosol sampling at high altitudes, very little is known about the abundance, diversity, and extent of microbial taxa in the Earth-atmosphere system. To directly address this knowledge gap, we designed, constructed, and tested a system that passively samples aerosols during ascent through the atmosphere while tethered to a helium-filled latex sounding balloon. The sampling payload is ~ 2.7 kg and comprised of an electronics box and three sampling chambers (one serving as a procedural control). Each chamber is sealed with retractable doors that can be commanded to open and close at designated altitudes. The payload is deployed together with radio beacons that transmit GPS coordinates (latitude, longitude and altitude) in real time for tracking and recovery. A cut mechanism separates the payload string from the balloon at any desired altitude, returning all equipment safely to the ground on a parachute. When the chambers are opened, aerosol sampling is performed using the Rotorod® collection method (40 rods per chamber), with each rod passing through 0.035 m3 per km of altitude sampled. Based on quality control measurements, the collection of ~ 100 cells rod(-1) provided a 3-sigma confidence level of detection. The payload system described can be mated with any type of balloon platform and provides a tool for characterizing the vertical distribution of microorganisms in the troposphere and stratosphere. PMID:25455021

  6. Genomic DNA microextraction: a method to screen numerous samples.

    PubMed

    Ramírez-Solis, R; Rivera-Pérez, J; Wallace, J D; Wims, M; Zheng, H; Bradley, A

    1992-03-01

    Many experimental designs require the analysis of genomic DNA from a large number of samples. Although the polymerase chain reaction (PCR) can be used, the Southern blot is preferred for many assays because of its inherent reliability. The rapid acceptance of PCR, despite a significant rate of false positive/negative results, is partly due to the disadvantages of the sample preparation process for Southern blot analysis. We have devised a rapid protocol to extract high-molecular-weight genomic DNA from a large number of samples. It involves the use of a single 96-well tissue culture dish to carry out all the steps of the sample preparation. This, coupled with the use of a multichannel pipette, facilitates the simultaneous analysis of multiple samples. The procedure may be automated since no centrifugation, mixing, or transferring of the samples is necessary. The method has been used to screen embryonic stem cell clones for the presence of targeted mutations at the Hox-2.6 locus and to obtain data from human blood.

  7. Transuranic waste characterization sampling and analysis methods manual. Revision 1

    SciTech Connect

    Suermann, J.F.

    1996-04-01

    This Methods Manual provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) for the Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) and the WIPP Waste Analysis Plan. This Methods Manual includes all of the testing, sampling, and analytical methodologies accepted by DOE for use in implementing the Program requirements specified in the QAPP and the WIPP Waste Analysis Plan. The procedures in this Methods Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site-specific procedures. With some analytical methods, such as Gas Chromatography/Mass Spectrometry, the Methods Manual procedures may be used directly. With other methods, such as nondestructive characterization, the Methods Manual provides guidance rather than a step-by-step procedure. Sites must meet all of the specified quality control requirements of the applicable procedure. Each DOE site must document the details of the procedures it will use and demonstrate the efficacy of such procedures to the Manager, National TRU Program Waste Characterization, during Waste Characterization and Certification audits.

  8. Laboratory development and field evaluation of a generic method for sampling and analysis of isocyanates. Revised final report

    SciTech Connect

    McGaughey, J.F.; Foster, S.C.; Merrill, R.G.

    1995-09-01

    The U.S. Environmental Protection Agency (EPA), under the authority of Title III of the Clean Air Act Amendments (CAAA) of 1990, requires the identification and validation of sampling and analytical methods for the isocyanate compounds which are listed among the 189 hazardous air pollutants identified in Title III. In all, three field tests were performed to accomplish the isocyanate field evaluation. The objective of this work was to develop and evaluate the isocyanate sampling and analytical test method through field testing at operating stationary sources. The method was evaluated by collecting flue gas samples for the analysis of the individual isocyanate and evaluating the data for bias and precision. EPA Method 301, Field Validation of Pollutant Measurement Methods from Various Waste Media, was used as the model for the experimental design of this method evaluation project.

  9. DNA sequences identical to Pneumocystis carinii f. sp. carinii and Pneumocystis carinii f. sp. hominis in samples of air spora.

    PubMed Central

    Wakefield, A E

    1996-01-01

    Samples of ambient air collected with three different types of spore traps in a rural location were examined for the presence of Pneumocystis carinii by screening for P. carinii-specific DNA sequences by DNA amplification. Eleven spore trap samples were analyzed by nested PCR, using oligonucleotide primers designed for the gene encoding the mitochondrial large subunit rRNA of P. carinii f. sp. carinii and P. carinii f. sp. hominis. The samples were collected over a 3-year period during the months of May to September, with a range of sampling times from 9 to 240 h. One air sample from an animal facility housing P. carinii-infected rats was also examined. P. carinii-specific amplification products were obtained from samples from each of the spore traps. The amplification products from eight air samples were cloned and sequenced. The majority of the recombinants from each of these samples had sequences identical to those of P. carinii f. sp. carinii and P. carinii f. sp. hominis, and a number of clones had single-base differences. These data suggest that sequences identical to those of P. carinii f. sp. carinii and P. carinii f. sp. hominis can be detected in samples of air collected in a rural location and that P. carinii may be a component of the air spora of rural Oxfordshire. PMID:8784583

  10. Environmental Asbestos Assessment Manual Superfund Method for the Determination of Asbestos in Ambient Air Part 2: Technical Background Document

    EPA Science Inventory

    A sampling and analysis method for the determination of asbestos in air is presented in Part 1 of this report, under separate cover. This method is designed specifically to provide results suitable for supporting risk assessments at Superfund sites, although it is applicable t...

  11. 6S Return Samples: Assessment of Air Quality in the International Space Station (ISS) Based on Solid Sorbent Air Sampler (SSAS) and Formaldehyde Monitoring Kit (FMK) Analyses

    NASA Technical Reports Server (NTRS)

    James, John T.

    2004-01-01

    The toxicological assessments of SSAS and FMK analytical results are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the SSAS tubes were 66-76% for 13C-acetone, 85-96% for fluorobenzene, and 73-89% for chlorobenzene. Post-flight flows were far below pre-flight flows and an investigation of the problem revealed that the reduced flow was caused by a leak at the interface of the pump inlet tube and the pump head. This resulted in degradation of pump efficiency. Further investigation showed that the problem occurred before the SSAS was operated on orbit and that use of the post-flight flows yielded consistent and useful results. Recoveries from formaldehyde control badges were 86 to 104%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). The T values will not be reported for these data due to the flow anomaly. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) is not efficiently trapped by the sorbents used in the SSAS. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. These five indices of air quality are summarized.

  12. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY SOIL SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.; Noyes, G.

    2009-11-09

    A new rapid method for the determination of actinides in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for samples up to 2 grams in emergency response situations. The actinides in soil method utilizes a rapid sodium hydroxide fusion method, a lanthanum fluoride soil matrix removal step, and a streamlined column separation process with stacked TEVA, TRU and DGA Resin cartridges. Lanthanum was separated rapidly and effectively from Am and Cm on DGA Resin. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha sources are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency soil samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinides in soil results were reported within 4-5 hours with excellent quality.

  13. Comparison of clinical samples and methods in chronic cutaneous leishmaniasis.

    PubMed

    Eroglu, Fadime; Uzun, Soner; Koltas, Ismail Soner

    2014-11-01

    This study aimed at finding out the most effective clinical samples and methods in chronic cutaneous leishmaniasis (CCL). Smear, aspiration fluid, and filter paper samples were taken from 104 skin lesions of suspected cases with CCL, and they were compared using microscopic examination, culture, and molecular methods. We characterized four different forms of CCL and identified the causative agents in CCL forms using high-resolution melting curve real-time polymerase chain reaction assay. We observed that smear was detected to be the most sensitive (63.5%) among clinical samples, and real-time polymerase chain reaction method was the most sensitive (96.8%) among the methods used in diagnosis of CCL. We identified 68.8% Leishmania tropica and 31.2% L. infantum in papular lesions, 69.2% L. infantum and 30.8% L. tropica in nodular lesions, 57.9% L. tropica and 42.1% L. major in ulcerating plaque lesions, and 55.5% L. tropica and 44.5% L. major in noduloulcerative lesions in CCL patients.

  14. Spanish Multicenter Normative Studies (NEURONORMA Project): methods and sample characteristics.

    PubMed

    Peña-Casanova, Jordi; Blesa, Rafael; Aguilar, Miquel; Gramunt-Fombuena, Nina; Gómez-Ansón, Beatriz; Oliva, Rafael; Molinuevo, José Luis; Robles, Alfredo; Barquero, María Sagrario; Antúnez, Carmen; Martínez-Parra, Carlos; Frank-García, Anna; Fernández, Manuel; Alfonso, Verónica; Sol, Josep M

    2009-06-01

    This paper describes the methods and sample characteristics of a series of Spanish normative studies (The NEURONORMA project). The primary objective of our research was to collect normative and psychometric information on a sample of people aged over 49 years. The normative information was based on a series of selected, but commonly used, neuropsychological tests covering attention, language, visuo-perceptual abilities, constructional tasks, memory, and executive functions. A sample of 356 community dwelling individuals was studied. Demographics, socio-cultural, and medical data were collected. Cognitive normality was validated via informants and a cognitive screening test. Norms were calculated for midpoint age groups. Effects of age, education, and sex were determined. The use of these norms should improve neuropsychological diagnostic accuracy in older Spanish subjects. These data may also be of considerable use for comparisons with other normative studies. Limitations of these normative data are also commented on.

  15. Fine particle exposure of prescribed fire workers in the Southeastern United States and a comparison of several particulate matter sampling methods.

    SciTech Connect

    Yanosky, Jeffrey, David

    2001-07-01

    Personal exposure concentrations of particles with aerodynamic diameter <2.5 μm (PM2.5) of prescribed fire workers were measured at two locations in the southeastern United States. Non-impacted ambient concentrations were measured as an estimate of background concentrations during burn activities. Four sampling method comparison studies were designed and performed to compare the FRM with 1) other gravimetric PM2.5 sampling methods in ambient air, 2) optical PM2.5 sampling methods in indoor air, 3) an optical sampling method (Grimm) for particles with aerodynamic diameter <10 μm (PM10) in ambient air, and 4) a gravimetric PM2.5 sampling method downwind of prescribed fires. The gravimetric PM2.5 sampling methods agreed well in ambient air (R2>0.96 for all) except for the MiniVol, the optical PM2.5 sampling methods agree less well in indoor air,(R2>0.592), the Grimm optical PM10 method agrees well in ambient air(R2>0.944 for all), and the personal method agrees well (n=9, R2=0.994) downwind of prescribed fires.

  16. Total Particulate Matter Air Sampling Data (TEOM) from Los Alamos National Laboratory

    DOE Data Explorer

    LANL measures the total particulate mass concentration in the air on a routine basis as well as during incidents that may affect ambient air. The collected data is added to the Air Quality Index (AQI). AQI is an index for reporting daily air quality. It tells you how clean or polluted your air is, and what associated health effects might be a concern for you. The AQI focuses on health effects you may experience within a few hours or days after breathing polluted air. EPA calculates the AQI for five major air pollutants regulated by the Clean Air Act.

  17. Evaluation of sample preservation methods for poultry manure.

    PubMed

    Pan, J; Fadel, J G; Zhang, R; El-Mashad, H M; Ying, Y; Rumsey, T

    2009-08-01

    When poultry manure is collected but cannot be analyzed immediately, a method for storing the manure is needed to ensure accurate subsequent analyses. This study has 3 objectives: (1) to investigate effects of 4 poultry manure sample preservation methods (refrigeration, freezing, acidification, and freeze-drying) on the compositional characteristics of poultry manure; (2) to determine compositional differences in fresh manure with manure samples at 1, 2, and 3 d of accumulation under bird cages; and (3) to assess the influence of 14-d freezing storage on the composition of manure when later exposed to 25 degrees C for 7 d as compared with fresh manure. All manure samples were collected from a layer house. Analyses performed on the manure samples included total Kjeldahl nitrogen, uric acid nitrogen, ammonia nitrogen, and urea nitrogen. In experiment 1, the storage methods most similar to fresh manure, in order of preference, were freezing, freeze-drying, acidification, and refrigeration. Thoroughly mixing manure samples and compressing them to 2 to 3 mm is important for the freezing and freeze-dried samples. In general, refrigeration was found unacceptable for nitrogen analyses. A significant effect (P < 0.0001) of time for refrigeration was found on uric acid nitrogen and ammonia nitrogen. In experiment 2, the total Kjeldahl nitrogen and uric acid nitrogen were significantly lower (P < 0.05) for 1, 2, and 3 d of accumulation compared with fresh manure. Manure after 1, 2, and 3 d of accumulation had similar nitrogen compositions. The results from experiment 3 show that nitrogen components from fresh manure samples and thawed samples from 14 d of freezing are similar at 7 d but high variability of nitrogen compositions during intermediate times from 0 to 7 d prevents the recommendation of freezing manure for use in subsequent experiments and warrants future experimentation. In conclusion, fresh poultry manure can be frozen for accurate subsequent nitrogen

  18. Evaluation of sample preservation methods for poultry manure.

    PubMed

    Pan, J; Fadel, J G; Zhang, R; El-Mashad, H M; Ying, Y; Rumsey, T

    2009-08-01

    When poultry manure is collected but cannot be analyzed immediately, a method for storing the manure is needed to ensure accurate subsequent analyses. This study has 3 objectives: (1) to investigate effects of 4 poultry manure sample preservation methods (refrigeration, freezing, acidification, and freeze-drying) on the compositional characteristics of poultry manure; (2) to determine compositional differences in fresh manure with manure samples at 1, 2, and 3 d of accumulation under bird cages; and (3) to assess the influence of 14-d freezing storage on the composition of manure when later exposed to 25 degrees C for 7 d as compared with fresh manure. All manure samples were collected from a layer house. Analyses performed on the manure samples included total Kjeldahl nitrogen, uric acid nitrogen, ammonia nitrogen, and urea nitrogen. In experiment 1, the storage methods most similar to fresh manure, in order of preference, were freezing, freeze-drying, acidification, and refrigeration. Thoroughly mixing manure samples and compressing them to 2 to 3 mm is important for the freezing and freeze-dried samples. In general, refrigeration was found unacceptable for nitrogen analyses. A significant effect (P < 0.0001) of time for refrigeration was found on uric acid nitrogen and ammonia nitrogen. In experiment 2, the total Kjeldahl nitrogen and uric acid nitrogen were significantly lower (P < 0.05) for 1, 2, and 3 d of accumulation compared with fresh manure. Manure after 1, 2, and 3 d of accumulation had similar nitrogen compositions. The results from experiment 3 show that nitrogen components from fresh manure samples and thawed samples from 14 d of freezing are similar at 7 d but high variability of nitrogen compositions during intermediate times from 0 to 7 d prevents the recommendation of freezing manure for use in subsequent experiments and warrants future experimentation. In conclusion, fresh poultry manure can be frozen for accurate subsequent nitrogen

  19. A probabilistic method to diagnose faults of air handling units

    NASA Astrophysics Data System (ADS)

    Dey, Debashis

    Air handling unit (AHU) is one of the most extensively used equipment in large commercial buildings. This device is typically customized and lacks quality system integration which can result in hardwire failures and controller errors. Air handling unit Performance Assessment Rules (APAR) is a fault detection tool that uses a set of expert rules derived from mass and energy balances to detect faults in air handling units. APAR is computationally simple enough that it can be embedded in commercial building automation and control systems and relies only upon sensor data and control signals that are commonly available in these systems. Although APAR has many advantages over other methods, for example no training data required and easy to implement commercially, most of the time it is unable to provide the diagnosis of the faults. For instance, a fault on temperature sensor could be fixed bias, drifting bias, inappropriate location, complete failure. Also a fault in mixing box can be return and outdoor damper leak or stuck. In addition, when multiple rules are satisfied the list of faults increases. There is no proper way to have the correct diagnosis for rule based fault detection system. To overcome this limitation we proposed Bayesian Belief Network (BBN) as a diagnostic tool. BBN can be used to simulate diagnostic thinking of FDD experts through a probabilistic way. In this study we developed a new way to detect and diagnose faults in AHU through combining APAR rules and Bayesian Belief network. Bayesian Belief Network is used as a decision support tool for rule based expert system. BBN is highly capable to prioritize faults when multiple rules are satisfied simultaneously. Also it can get information from previous AHU operating conditions and maintenance records to provide proper diagnosis. The proposed model is validated with real time measured data of a campus building at University of Texas at San Antonio (UTSA).The results show that BBN is correctly able to

  20. A Mixed Methods Investigation of Mixed Methods Sampling Designs in Social and Health Science Research

    ERIC Educational Resources Information Center

    Collins, Kathleen M. T.; Onwuegbuzie, Anthony J.; Jiao, Qun G.

    2007-01-01

    A sequential design utilizing identical samples was used to classify mixed methods studies via a two-dimensional model, wherein sampling designs were grouped according to the time orientation of each study's components and the relationship of the qualitative and quantitative samples. A quantitative analysis of 121 studies representing nine fields…

  1. Method for Measuring Thermal Conductivity of Small Samples Having Very Low Thermal Conductivity

    NASA Technical Reports Server (NTRS)

    Miller, Robert A.; Kuczmarski, Maria a.

    2009-01-01

    This paper describes the development of a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air. As with other approaches, care is taken to ensure that the heat flow through the test sample is essentially one-dimensional. However, unlike other approaches, no attempt is made to use heated guards to block the flow of heat from the hot plate to the surroundings. It is argued that since large correction factors must be applied to account for guard imperfections when sample dimensions are small, it may be preferable to simply measure and correct for the heat that flows from the heater disc to directions other than into the sample. Experimental measurements taken in a prototype apparatus, combined with extensive computational modeling of the heat transfer in the apparatus, show that sufficiently accurate measurements can be obtained to allow determination of the thermal conductivity of low thermal conductivity materials. Suggestions are made for further improvements in the method based on results from regression analyses of the generated data.

  2. Application of end-expired breath sampling to estimate carboxyhemoglobin levels in community air pollution exposure assessments

    NASA Astrophysics Data System (ADS)

    Lambert, William E.; Colome, Steven D.; Wojciechowski, Sandra L.

    Measurement of carbon monoxide (CO) in end-expired air after breath-holding permits the estimation of blood carboxyhemoglobin (COHb) levels. Some literature suggests that the precision of the method decreases at low COHb levels. As part of a community exposure and health study, the end-expired breath method was applied to estimate COHb levels in 28 men with ischemic heart disease. Paired samples of blood and breath were collected at the beginning and end of the 24-h CO monitoring periods. The aggregate regression of all subjects' COHb on breath CO displayed high variability. However, the variability was substantially reduced for any particular subject, promoting the use of individualized blood-breath standard curves to improve the precision of COHb estimates made from breath CO. The ultimate accuracy of the blood-breath relationship could not be resolved by our data. Two major sources of error are identified. The observed person-to-person variability may be caused by physiologic factors or differences in ability to deliver an end-expired breath sample representative of alveolar air. This variation may also be due to instrumentation factors, specifically the accuracy of the IL282 CO-Oximeter at 0-3% levels. Further research into the sources of variability in the end-expired breath method is recommended. Epidemiologists using similar end-expired breath measurements to predict COHb levels should be cognizant of the magnitude and probable direction of the error in COHb estimates. This non-invasive method should continue to allow evaluation of the success of personal monitoring efforts and pharmacokinetic modeling of CO uptake in community exposure research.

  3. A direct method for e-cigarette aerosol sample collection.

    PubMed

    Olmedo, Pablo; Navas-Acien, Ana; Hess, Catherine; Jarmul, Stephanie; Rule, Ana

    2016-08-01

    E-cigarette use is increasing in populations around the world. Recent evidence has shown that the aerosol produced by e-cigarettes can contain a variety of toxicants. Published studies characterizing toxicants in e-cigarette aerosol have relied on filters, impingers or sorbent tubes, which are methods that require diluting or extracting the sample in a solution during collection. We have developed a collection system that directly condenses e-cigarette aerosol samples for chemical and toxicological analyses. The collection system consists of several cut pipette tips connected with short pieces of tubing. The pipette tip-based collection system can be connected to a peristaltic pump, a vacuum pump, or directly to an e-cigarette user for the e-cigarette aerosol to flow through the system. The pipette tip-based system condenses the aerosol produced by the e-cigarette and collects a liquid sample that is ready for analysis without the need of intermediate extraction solutions. We tested a total of 20 e-cigarettes from 5 different brands commercially available in Maryland. The pipette tip-based collection system condensed between 0.23 and 0.53mL of post-vaped e-liquid after 150 puffs. The proposed method is highly adaptable, can be used during field work and in experimental settings, and allows collecting aerosol samples from a wide variety of e-cigarette devices, yielding a condensate of the likely exact substance that is being delivered to the lungs.

  4. A direct method for e-cigarette aerosol sample collection.

    PubMed

    Olmedo, Pablo; Navas-Acien, Ana; Hess, Catherine; Jarmul, Stephanie; Rule, Ana

    2016-08-01

    E-cigarette use is increasing in populations around the world. Recent evidence has shown that the aerosol produced by e-cigarettes can contain a variety of toxicants. Published studies characterizing toxicants in e-cigarette aerosol have relied on filters, impingers or sorbent tubes, which are methods that require diluting or extracting the sample in a solution during collection. We have developed a collection system that directly condenses e-cigarette aerosol samples for chemical and toxicological analyses. The collection system consists of several cut pipette tips connected with short pieces of tubing. The pipette tip-based collection system can be connected to a peristaltic pump, a vacuum pump, or directly to an e-cigarette user for the e-cigarette aerosol to flow through the system. The pipette tip-based system condenses the aerosol produced by the e-cigarette and collects a liquid sample that is ready for analysis without the need of intermediate extraction solutions. We tested a total of 20 e-cigarettes from 5 different brands commercially available in Maryland. The pipette tip-based collection system condensed between 0.23 and 0.53mL of post-vaped e-liquid after 150 puffs. The proposed method is highly adaptable, can be used during field work and in experimental settings, and allows collecting aerosol samples from a wide variety of e-cigarette devices, yielding a condensate of the likely exact substance that is being delivered to the lungs. PMID:27200479

  5. Methods for the analysis of carpet samples for asbestos

    SciTech Connect

    Millette, J.R.; Clark, P.J.; Brackett, K.A.; Wheeles, R.K.

    1993-01-01

    Because of the nature of carpet pile, no samples can be directly prepared from carpet for analysis by transmission electron microscopy (TEM). Two indirect methods are currently used by laboratories when preparing samples for measuring the amount of asbestos present in carpet material. One is an ultrasonic shaking technique which requires that a portion of the carpet be cut and sent to the laboratory. The other is a micro-vacuuming technique which has been used generally in the assessment of asbestos in settled dust in buildings. It is not destructive to the carpet. Both methods utilize TEM to identify, measure and count the asbestos fibers found. Each can provide important but different information when an assessment of the level of contamination of carpeting is being made.

  6. On eddy accumulation with limited conditional sampling to measure air-surface exchange

    SciTech Connect

    Wesely, M.L.; Hart, R.L.

    1994-01-01

    An analysis of turbulence data collected at a height of 12.3 m above grasslands was carried out to illustrate some of the limitations and possible improvements in methods to compute vertical fluxes of trace substances by the eddy accumulation technique with conditional sampling. The empirical coefficient used in the technique has a slight dependence on atmospheric stability, which can be minimized by using a threshold vertical velocity equal to approximately 0.75{sigma}{sub w}, below which chemical sampling is suspended. This protocol results in a smaller chemical sample but increases the differences in concentrations by approximately 70%. For effective conditional sampling when mass is being accumulated in a trap or reservoir, the time of sampling during updrafts versus downdrafts should be measured and used to adjust estimates of the mean concentrations.

  7. Pesticides in Air and Rainwater in the Midcontinental United States, 1995 - Methods and Data

    USGS Publications Warehouse

    Majewski, Michael S.; Foreman, William T.; Coupe, Richard H.; Goolsby, Donald A.; Wiebe, Frank W.

    2008-01-01

    Weekly composite high-volume air and wet-only deposition samples were collected from April through September 1995 at paired urban and agricultural areas in Mississippi, Iowa, and Minnesota, and at a background site in Michigan?s Upper Peninsula. This report describes the methods used to collect, analyze, and quality assure the samples, and presents the results of all chemical analyses and quality control procedures. Each sample was analyzed for 49 compounds, including several pesticides not examined in previous atmospheric studies. Eighty-five percent of the herbicides, 70 percent of the insecticides, and 100 percent of the transformation products that were targeted for analysis were detected in one or more samples at each paired site.

  8. The experience sampling method: Investigating students' affective experience

    NASA Astrophysics Data System (ADS)

    Nissen, Jayson M.; Stetzer, MacKenzie R.; Shemwell, Jonathan T.

    2013-01-01

    Improving non-cognitive outcomes such as attitudes, efficacy, and persistence in physics courses is an important goal of physics education. This investigation implemented an in-the-moment surveying technique called the Experience Sampling Method (ESM) [1] to measure students' affective experience in physics. Measurements included: self-efficacy, cognitive efficiency, activation, intrinsic motivation, and affect. Data are presented that show contrasts in students' experiences (e.g., in physics vs. non-physics courses).

  9. Rock sampling. [method for controlling particle size distribution

    NASA Technical Reports Server (NTRS)

    Blum, P. (Inventor)

    1971-01-01

    A method for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The method involves cutting grooves in the rock surface to provide a grouping of parallel ridges and subsequently machining the ridges to provide a powder specimen. The machining step may comprise milling, drilling, lathe cutting or the like; but a planing step is advantageous. Control of the particle size distribution is effected primarily by changing the height and width of these ridges. This control exceeds that obtainable by conventional grinding.

  10. A new radiograpic method using electromagnetic component of air shower

    NASA Astrophysics Data System (ADS)

    Taketa, A.; Okubo, S.; Tanaka, H.

    2012-12-01

    We have developed a novel radiographic method to measure the density length with electromagnetic component of air shower. Air shower produced by a primary cosmic ray consists of muon component and electromagnetic component. Electromagnetic component is consists of electron, positron and photon. The penetration power of electromagnetic component is weaker than that of muon, so soft component is suitable for small scale structure thinner than 2 kg/cm^2 equivalent to 20m thick water, like buildings and small hills. But it requires particle identification which means distinguishing muon and electromagnetic component. Particle identification can be done with strong magnets and dense detectors, but it is very hard to use that kind of detector for radiography because of their weight and cost. We established the cheap and effective method to distinguish soft component and hard component statistically. We also performed measurements in Arimura observation vault of Mt. Sakurajima, Japan. As a result of this observation, we found there is an anti-correlation between soft component flux and rainfall. If the water content of the soil became larger, the amount of absorption increases. So this result can be interpreted as detecting the increase of the water content by soft component flux. This method can be applied for the quantitive compensation of the measurement data like absolute gravitymeter data and tiltmeter data which is easy to receive turbulence by rain. It is also expected that the quantitive compensation leads to the improvement in accuracy of diastrophism measurement and the improvement in presumed accuracy of magma movement inside a volcano.

  11. Environmental equity research: review with focus on outdoor air pollution research methods and analytic tools.

    PubMed

    Miao, Qun; Chen, Dongmei; Buzzelli, Michael; Aronson, Kristan J

    2015-01-01

    The objective of this study was to review environmental equity research on outdoor air pollution and, specifically, methods and tools used in research, published in English, with the aim of recommending the best methods and analytic tools. English language publications from 2000 to 2012 were identified in Google Scholar, Ovid MEDLINE, and PubMed. Research methodologies and results were reviewed and potential deficiencies and knowledge gaps identified. The publications show that exposure to outdoor air pollution differs by social factors, but findings are inconsistent in Canada. In terms of study designs, most were small and ecological and therefore prone to the ecological fallacy. Newer tools such as geographic information systems, modeling, and biomarkers offer improved precision in exposure measurement. Higher-quality research using large, individual-based samples and more precise analytic tools are needed to provide better evidence for policy-making to reduce environmental inequities.

  12. Automated fluorometric method for hydrogen peroxide in air

    SciTech Connect

    Lazrus, A.L.; Kok, G.L.; Lind, J.A.; Gitlin, S.N.; Heikes, B.G.; Shetter, R.E.

    1986-03-01

    A fluorometric method for measuring H/sub 2/O/sub 2/ vapor in air utilizes peroxidase enzyme to catalyze the reaction in which hydroperoxides cause dimerization of (p-hydroxyphenyl)acetic acid. In a second channel, H/sub 2/O/sub 2/ is selectively decomposed by catalase so that the fluorescence signal is due only to organic hydroperoxides. The difference between the two signals is a measure of H/sub 2/O/sub 2/ vapor. The H/sub 2/O/sub 2/ vapor is collected by means of a glass coil though which air and water flow concurrently. The coefficient of variation is 0.5% at 2.5 parts per billion by volume. The standard deviation of the base line is 10 parts per trillion by volume (pptv) under laboratory conditions. This standard deviation has varied between 3 and 33 pptv during ground-based field missions, and was 70 pptv on aircraft flights. Thirty seconds is required for the signal to change from 10 to 90% of its maximum value. 13 references, 4 figures, 1 table.

  13. Air-Based Remediation Workshop - Section 1 Sampling And Analysis Revelant To Air-Based Remediation Technologies

    EPA Science Inventory

    Pursant to the EPA-AIT Implementing Arrangement 7 for Technical Environmental Collaboration, Activity 11 "Remediation of Contaminated Sites," the USEPA Office of International Affairs Organized a Force Air Remediation Workshop in Taipei to deliver expert training to the Environme...

  14. Sediment sampling and processing methods in Hungary, and possible improvements

    NASA Astrophysics Data System (ADS)

    Tamas, Eniko Anna; Koch, Daniel; Varga, Gyorgy

    2016-04-01

    The importance of the monitoring of sediment processes is unquestionable: sediment balance of regulated rivers suffered substantial alterations in the past century, affecting navigation, energy production, fish habitats and floodplain ecosystems alike; infiltration times to our drinking water wells have shortened, exposing them to an eventual pollution event and making them vulnerable; and sediment-attached contaminants accumulate in floodplains and reservoirs, threatening our healthy environment. The changes in flood characteristics and rating curves of our rivers are regularly being researched and described, involving state-of-the-art measurement methods, modeling tools and traditional statistics. Sediment processes however, are much less known. Unlike the investigation of flow processes, sediment-related research is scarce, which is partly due to the outdated methodology and poor database background in the specific field. Sediment-related data, information and analyses form an important and integral part of Civil engineering in relation to rivers all over the world. In relation to the second largest river of Europe, the Danube, it is widely known in expert community and for long discussed at different expert forums that the sediment balance of the river Danube has changed drastically over the past century. Sediment monitoring on the river Danube started as early as the end of the 19th century, with scattered measurements carried out. Regular sediment sampling was developed in the first half of the 20th century all along the river, with different station density and monitoring frequencies in different countries. After the first few decades of regular sampling, the concept of (mainly industrial) development changed along the river and data needs changed as well, furthermore the complicated and inexact methods of sampling bed load on the alluvial reach of the river were not developed further. Frequency of suspended sediment sampling is very low along the river

  15. Sediment sampling and processing methods in Hungary, and possible improvements

    NASA Astrophysics Data System (ADS)

    Tamas, Eniko Anna; Koch, Daniel; Varga, Gyorgy

    2016-04-01

    The importance of the monitoring of sediment processes is unquestionable: sediment balance of regulated rivers suffered substantial alterations in the past century, affecting navigation, energy production, fish habitats and floodplain ecosystems alike; infiltration times to our drinking water wells have shortened, exposing them to an eventual pollution event and making them vulnerable; and sediment-attached contaminants accumulate in floodplains and reservoirs, threatening our healthy environment. The changes in flood characteristics and rating curves of our rivers are regularly being researched and described, involving state-of-the-art measurement methods, modeling tools and traditional statistics. Sediment processes however, are much less known. Unlike the investigation of flow processes, sediment-related research is scarce, which is partly due to the outdated methodology and poor database background in the specific field. Sediment-related data, information and analyses form an important and integral part of Civil engineering in relation to rivers all over the world. In relation to the second largest river of Europe, the Danube, it is widely known in expert community and for long discussed at different expert forums that the sediment balance of the river Danube has changed drastically over the past century. Sediment monitoring on the river Danube started as early as the end of the 19th century, with scattered measurements carried out. Regular sediment sampling was developed in the first half of the 20th century all along the river, with different station density and monitoring frequencies in different countries. After the first few decades of regular sampling, the concept of (mainly industrial) development changed along the river and data needs changed as well, furthermore the complicated and inexact methods of sampling bed load on the alluvial reach of the river were not developed further. Frequency of suspended sediment sampling is very low along the river

  16. Comparison of methods for the quantification of carbonate carbon in atmospheric PM10 aerosol samples

    NASA Astrophysics Data System (ADS)

    Jankowski, Nicole; Schmidl, Christoph; Marr, Iain L.; Bauer, Heidi; Puxbaum, Hans

    Carbonate carbon (CC) represents an important fraction of atmospheric PM10 along with organic carbon (OC) and elemental carbon (EC), if specific sources (e.g. street abrasion, construction sites, desert dust) contribute to its composition. However, analytical methods for an easy and unambiguous determination of CC in atmospheric aerosols collected on filter matrices are scarce. We propose here a method for the determination of CC based on a heating pretreatment of the sample to remove OC and EC, followed by a total carbon determination to measure CC. This procedure is used for the correction of EC also determined by a heating pretreatment (Cachier, H., Bremond, M.P., Buat-Ménard, P., 1989. Determination of atmospheric soot carbon with a simple thermal method. Tellus 41B, 379-390) but without previous HCl fumigation, as proposed. Comparison of the carbon remaining after the proposed thermal treatment at 460 °C for 60 min in an oxygen stream showed good correlation for the carbonate carbon derived by calculation from the ionic balance for ambient air and street dust samples. Using the "three step" combustion technique it is now possible to determine OC, EC and CC by the use of a TC analyser in the concentration range of 2-200 μg carbon per sample aliquot, with good precision (3-5% RSD for TC and 5-10% for CC) and accuracy. In ambient air samples from a sampling site in Vienna with elevated PM10 levels ("Liesing") CC values as high as 25% of TC and 27% CO 32-; for street dust samples 32% of TC and 25% CO 32- of total PM10 mass were observed.

  17. Unmanned platform for long-range remote analysis of volatile compounds in air samples.

    PubMed

    da Costa, Eric T; Neves, Carlos A; Hotta, Guilherme M; Vidal, Denis T R; Barros, Marcelo F; Ayon, Arturo A; Garcia, Carlos D; do Lago, Claudimir Lucio

    2012-09-01

    This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV.

  18. Unmanned platform for long-range remote analysis of volatile compounds in air samples.

    PubMed

    da Costa, Eric T; Neves, Carlos A; Hotta, Guilherme M; Vidal, Denis T R; Barros, Marcelo F; Ayon, Arturo A; Garcia, Carlos D; do Lago, Claudimir Lucio

    2012-09-01

    This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV. PMID:22965708

  19. A review of methods for predicting air pollution dispersion

    NASA Technical Reports Server (NTRS)

    Mathis, J. J., Jr.; Grose, W. L.

    1973-01-01

    Air pollution modeling, and problem areas in air pollution dispersion modeling were surveyed. Emission source inventory, meteorological data, and turbulent diffusion are discussed in terms of developing a dispersion model. Existing mathematical models of urban air pollution, and highway and airport models are discussed along with their limitations. Recommendations for improving modeling capabilities are included.

  20. 24-HOUR DIFFUSIVE SAMPLING OF TOXIC VOCS IN AIR ONTO CARBOPACK X SOLID ADSORBENT FOLLOWED BY THERMAL DESORPTION/GC/MS ANALYSIS - LABORATORY STUDIES

    EPA Science Inventory

    Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity, and ozon...

  1. Tracing Ambient Air Geochemistry using a Modified X-Ray Fluorescence Filter Method

    NASA Astrophysics Data System (ADS)

    Steiner, J. C.; Rudolph, E.; Wrice, T.

    2002-12-01

    Modifications of x-ray fluorescence counting procedures enable tracing of aerosol dispersals related to weather fronts and local weather phenomena. Improved X-ray fluorescence methods for bulk aerosols deposited under positive air pressure conditions onto Millipore filters at 80 liters/hour enable the tracing of geological samples in periods down to one hour. Vacuum-plating aliquots of USGS standards onto 0.2 micron polycarbonate and quartz Millipore filters create standards with a shelf life of several months. The analytical system permits detection of light oxides, such as silica to 10 ppm, and heavy elements, such as iron to 0.5 ppm. These collections allow discriminations to be drawn between dominantly geological, silica-enriched air mass and dominantly iron-enriched air of possible industrial origin. These ambient air collections at 120 feet elevation at City College are used to create possible distinctions in air masses related to points of origin. Splits of aerosol examined by neutron activation and coupled plasma emission spectroscopy agree with x-ray fluorescence methods to within analytical error. Aerosol flux conditions are monitored for speciation using direct examination by scanning electron microscopy with energy dispersive analytical capability plus aerosol physical properties by sun photometry. The latter provides bulk optical transmission at six major wavelengths and estimates for bulk aerosol size properties. Preliminary data show positive photometry links with iron-aerosols with a correlation coefficient with southwesterly wind-driven conditions of seventy percent over a four hour monitoring period. Aerosol flux comparisons with heavy metal populations, Ba, Rb, Zr, La show uniform distributions with iron- and silica-enriched populations indicating a pervasive background condition in the ambient air mass over New York City.

  2. RAZOR EX Anthrax Air Detection System for detection of Bacillus anthracis spores from aerosol collection samples: collaborative study.

    PubMed

    Hadfield, Ted; Ryan, Valorie; Spaulding, Usha K; Clemens, Kristine M; Ota, Irene M; Brunelle, Sharon L

    2013-01-01

    The RAZOR EX Anthrax Air Detection System was validated in a collaborative study for the detection of Bacillus anthracis in aerosol collection buffer. Phosphate-buffered saline was charged with 1 mg/mL standardized dust to simulate an authentic aerosol collection sample. The dust-charged buffer was spiked with either B. anthracis Ames at 2000 spores/mL or Bacillus cereus at 20 000 spores/mL. Twelve collaborators participated in the study, with four collaborators at each of three sites. Each collaborator tested 12 replicates of B. anthracis in dust-charged buffer and 12 replicates of B. cereus in dust-charged buffer. All samples sets were randomized and blind-coded. All collaborators produced valid data sets (no collaborators displayed systematic errors) and there was only one invalid data point. After unblinding, the analysis revealed a cross-collaborator probability of detection (CPOD) of 1.00 (144 positive results from 144 replicates, 95% confidence interval 0.975-1.00) for the B. anthracis samples and a CPOD of 0.00 (0 positive results from 143 replicates, 95% confidence interval 0.00-0.0262) for the B. cereus samples. These data meet the requirements of AOAC Standard Method Performance Requirement 2010.003, developed by the Stakeholder Panel on Agent Detection Assays. PMID:23767365

  3. Sampling of power plant stacks for air toxic emissions: Topical report for Phases 1 and 2

    SciTech Connect

    1995-02-21

    Under contract with the US Department of Energy (DE-AC22-92PCO0367), Pittsburgh Energy Technology Center, Radian Corporation has conducted a test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPS). Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical charactization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions.

  4. Quantification of VX vapor in ambient air by liquid chromatography isotope dilution tandem mass spectrometric analysis of glass bead filled sampling tubes.

    PubMed

    Evans, Ronald A; Smith, Wendy L; Nguyen, Nam-Phuong; Crouse, Kathy L; Crouse, Charles L; Norman, Steven D; Jakubowski, E Michael

    2011-02-15

    An analysis method has been developed for determining low parts-per-quadrillion by volume (ppqv) concentrations of nerve agent VX vapor actively sampled from ambient air. The method utilizes glass bead filled depot area air monitoring system (DAAMS) sampling tubes with isopropyl alcohol extraction and isotope dilution using liquid chromatography coupled with a triple-quadrupole mass spectrometer (LC/MS/MS) with positive ion electrospray ionization for quantitation. The dynamic range was from one-tenth of the worker population limit (WPL) to the short-term exposure limit (STEL) for a 24 L air sample taken over a 1 h period. The precision and accuracy of the method were evaluated using liquid-spiked tubes, and the collection characteristics of the DAAMS tubes were assessed by collecting trace level vapor generated in a 1000 L continuous flow chamber. The method described here has significant improvements over currently employed thermal desorption techniques that utilize a silver fluoride pad during sampling to convert VX to a higher volatility G-analogue for gas chromatographic analysis. The benefits of this method are the ability to directly analyze VX with improved selectivity and sensitivity, the injection of a fraction of the extract, quantitation using an isotopically labeled internal standard, and a short instrument cycle time.

  5. Method Evaluation And Field Sample Measurements For The Rate Of Movement Of The Oxidation Front In Saltstone

    SciTech Connect

    Almond, P. M.; Kaplan, D. I.; Langton, C. A.; Stefanko, D. B.; Spencer, W. A.; Hatfield, A.; Arai, Y.

    2012-08-23

    The objective of this work was to develop and evaluate a series of methods and validate their capability to measure differences in oxidized versus reduced saltstone. Validated methods were then applied to samples cured under field conditions to simulate Performance Assessment (PA) needs for the Saltstone Disposal Facility (SDF). Four analytical approaches were evaluated using laboratory-cured saltstone samples. These methods were X-ray absorption spectroscopy (XAS), diffuse reflectance spectroscopy (DRS), chemical redox indicators, and thin-section leaching methods. XAS and thin-section leaching methods were validated as viable methods for studying oxidation movement in saltstone. Each method used samples that were spiked with chromium (Cr) as a tracer for oxidation of the saltstone. The two methods were subsequently applied to field-cured samples containing chromium to characterize the oxidation state of chromium as a function of distance from the exposed air/cementitious material surface.

  6. Pteam: Monitoring of phthalates and PAHs in indoor and outdoor air samples in Riverside, California. Volume 2. Final report

    SciTech Connect

    Sheldon, L.; Clayton, A.; Keever, J.; Perritt, R.; Whitaker, D.

    1992-12-01

    The primary purpose of the study was to obtain indoor and outdoor air concentration data for benzo(a)pyrene, other polynuclear aromatic hydrocarbons (PAHs), and phthalates in California residences to be used in making exposure predictions. To meet these objectives, a field monitoring study was performed in 125 homes in Riverside, California in the fall of 1990. In each home, two 12-hour indoor air samples were collected during daytime and overnight periods. In a subset of 65 homes, outdoor air samples were also collected. PAH and phthalate concentrations were measured in collected air samples using gas chromatography/mass spectrometry techniques. Along with field monitoring, information on potential source usage in the home was collected using questionnaires.

  7. GUIDE TO CALCULATING TRANSPORT EFFICIENCY OF AEROSOLS IN OCCUPATIONAL AIR SAMPLING SYSTEMS

    SciTech Connect

    Hogue, M.; Hadlock, D.; Thompson, M.; Farfan, E.

    2013-11-12

    This report will present hand calculations for transport efficiency based on aspiration efficiency and particle deposition losses. Because the hand calculations become long and tedious, especially for lognormal distributions of aerosols, an R script (R 2011) will be provided for each element examined. Calculations are provided for the most common elements in a remote air sampling system, including a thin-walled probe in ambient air, straight tubing, bends and a sample housing. One popular alternative approach would be to put such calculations in a spreadsheet, a thorough version of which is shared by Paul Baron via the Aerocalc spreadsheet (Baron 2012). To provide greater transparency and to avoid common spreadsheet vulnerabilities to errors (Burns 2012), this report uses R. The particle size is based on the concept of activity median aerodynamic diameter (AMAD). The AMAD is a particle size in an aerosol where fifty percent of the activity in the aerosol is associated with particles of aerodynamic diameter greater than the AMAD. This concept allows for the simplification of transport efficiency calculations where all particles are treated as spheres with the density of water (1g cm-3). In reality, particle densities depend on the actual material involved. Particle geometries can be very complicated. Dynamic shape factors are provided by Hinds (Hinds 1999). Some example factors are: 1.00 for a sphere, 1.08 for a cube, 1.68 for a long cylinder (10 times as long as it is wide), 1.05 to 1.11 for bituminous coal, 1.57 for sand and 1.88 for talc. Revision 1 is made to correct an error in the original version of this report. The particle distributions are based on activity weighting of particles rather than based on the number of particles of each size. Therefore, the mass correction made in the original version is removed from the text and the calculations. Results affected by the change are updated.

  8. Method for microRNA isolation from clinical serum samples.

    PubMed

    Li, Yu; Kowdley, Kris V

    2012-12-01

    MicroRNAs are a group of intracellular noncoding RNA molecules that have been implicated in a variety of human diseases. Because of their high stability in blood, microRNAs released into circulation could be potentially utilized as noninvasive biomarkers for diagnosis or prognosis. Current microRNA isolation protocols are specifically designed for solid tissues and are impractical for biomarker development utilizing small-volume serum samples on a large scale. Thus, a protocol for microRNA isolation from serum is needed to accommodate these conditions in biomarker development. To establish such a protocol, we developed a simplified approach to normalize sample input by using single synthetic spike-in microRNA. We evaluated three commonly used commercial microRNA isolation kits for the best performance by comparing RNA quality and yield. The manufacturer's protocol was further modified to improve the microRNA yield from 200μl of human serum. MicroRNAs isolated from a large set of clinical serum samples were tested on the miRCURY LNA real-time PCR panel and confirmed to be suitable for high-throughput microRNA profiling. In conclusion, we have established a proven method for microRNA isolation from clinical serum samples suitable for microRNA biomarker development.

  9. Hand held sample tube manipulator, system and method

    DOEpatents

    Kenny, Donald V [Liberty Township, OH; Smith, Deborah L [Liberty Township, OH; Severance, Richard A [late of Columbus, OH

    2001-01-01

    A manipulator apparatus, system and method for measuring analytes present in sample tubes. The manipulator apparatus includes a housing having a central bore with an inlet end and outlet end; a plunger mechanism with at least a portion thereof slideably disposed for reciprocal movement within the central bore, the plunger mechanism having a tubular gas channel with an inlet end and an outlet end, the gas channel inlet end disposed in the same direction as said inlet end of the central bore, wherein the inlet end of said plunger mechanism is adapted for movement so as to expel a sample tube inserted in the bore at the outlet end of the housing, the inlet end of the plunger mechanism is adapted for connection to gas supply; a first seal is disposed in the housing for sealing between the central bore and the plunger mechanism; a second seal is disposed at the outlet end of the housing for sealing between the central bore and a sample tube; a holder mounted on the housing for holding the sample tube; and a biasing mechanism for returning the plunger mechanism to a starting position.

  10. Indoor air sampling for fine particulate matter and black carbon in industrial communities in Pittsburgh.

    PubMed

    Tunno, Brett J; Naumoff Shields, Kyra; Cambal, Leah; Tripathy, Sheila; Holguin, Fernando; Lioy, Paul; Clougherty, Jane E

    2015-12-01

    Impacts of industrial emissions on outdoor air pollution in nearby communities are well-documented. Fewer studies, however, have explored impacts on indoor air quality in these communities. Because persons in northern climates spend a majority of their time indoors, understanding indoor exposures, and the role of outdoor air pollution in shaping such exposures, is a priority issue. Braddock and Clairton, Pennsylvania, industrial communities near Pittsburgh, are home to an active steel mill and coke works, respectively, and the population experiences elevated rates of childhood asthma. Twenty-one homes were selected for 1-week indoor sampling for fine particulate matter (PM2.5) and black carbon (BC) during summer 2011 and winter 2012. Multivariate linear regression models were used to examine contributions from both outdoor concentrations and indoor sources. In the models, an outdoor infiltration component explained 10 to 39% of variability in indoor air pollution for PM2.5, and 33 to 42% for BC. For both PM2.5 models and the summer BC model, smoking was a stronger predictor than outdoor pollution, as greater pollutant concentration increases were identified. For winter BC, the model was explained by outdoor pollution and an open windows modifier. In both seasons, indoor concentrations for both PM2.5 and BC were consistently higher than residence-specific outdoor concentration estimates. Mean indoor PM2.5 was higher, on average, during summer (25.8±22.7 μg/m3) than winter (18.9±13.2 μg/m3). Contrary to the study's hypothesis, outdoor concentrations accounted for only little to moderate variability (10 to 42%) in indoor concentrations; a much greater proportion of PM2.5 was explained by cigarette smoking. Outdoor infiltration was a stronger predictor for BC compared to PM2.5, especially in winter. Our results suggest that, even in industrial communities of high outdoor pollution concentrations, indoor activities--particularly cigarette smoking--may play a larger

  11. Indoor air sampling for fine particulate matter and black carbon in industrial communities in Pittsburgh.

    PubMed

    Tunno, Brett J; Naumoff Shields, Kyra; Cambal, Leah; Tripathy, Sheila; Holguin, Fernando; Lioy, Paul; Clougherty, Jane E

    2015-12-01

    Impacts of industrial emissions on outdoor air pollution in nearby communities are well-documented. Fewer studies, however, have explored impacts on indoor air quality in these communities. Because persons in northern climates spend a majority of their time indoors, understanding indoor exposures, and the role of outdoor air pollution in shaping such exposures, is a priority issue. Braddock and Clairton, Pennsylvania, industrial communities near Pittsburgh, are home to an active steel mill and coke works, respectively, and the population experiences elevated rates of childhood asthma. Twenty-one homes were selected for 1-week indoor sampling for fine particulate matter (PM2.5) and black carbon (BC) during summer 2011 and winter 2012. Multivariate linear regression models were used to examine contributions from both outdoor concentrations and indoor sources. In the models, an outdoor infiltration component explained 10 to 39% of variability in indoor air pollution for PM2.5, and 33 to 42% for BC. For both PM2.5 models and the summer BC model, smoking was a stronger predictor than outdoor pollution, as greater pollutant concentration increases were identified. For winter BC, the model was explained by outdoor pollution and an open windows modifier. In both seasons, indoor concentrations for both PM2.5 and BC were consistently higher than residence-specific outdoor concentration estimates. Mean indoor PM2.5 was higher, on average, during summer (25.8±22.7 μg/m3) than winter (18.9±13.2 μg/m3). Contrary to the study's hypothesis, outdoor concentrations accounted for only little to moderate variability (10 to 42%) in indoor concentrations; a much greater proportion of PM2.5 was explained by cigarette smoking. Outdoor infiltration was a stronger predictor for BC compared to PM2.5, especially in winter. Our results suggest that, even in industrial communities of high outdoor pollution concentrations, indoor activities--particularly cigarette smoking--may play a larger

  12. A time domain sampling method for inverse acoustic scattering problems

    NASA Astrophysics Data System (ADS)

    Guo, Yukun; Hömberg, Dietmar; Hu, Guanghui; Li, Jingzhi; Liu, Hongyu

    2016-06-01

    This work concerns the inverse scattering problems of imaging unknown/inaccessible scatterers by transient acoustic near-field measurements. Based on the analysis of the migration method, we propose efficient and effective sampling schemes for imaging small and extended scatterers from knowledge of time-dependent scattered data due to incident impulsive point sources. Though the inverse scattering problems are known to be nonlinear and ill-posed, the proposed imaging algorithms are totally "direct" involving only integral calculations on the measurement surface. Theoretical justifications are presented and numerical experiments are conducted to demonstrate the effectiveness and robustness of our methods. In particular, the proposed static imaging functionals enhance the performance of the total focusing method (TFM) and the dynamic imaging functionals show analogous behavior to the time reversal inversion but without solving time-dependent wave equations.

  13. A Novel Method for Sampling Alpha-Helical Protein Backbones

    DOE R&D Accomplishments Database

    Fain, Boris; Levitt, Michael

    2001-01-01

    We present a novel technique of sampling the configurations of helical proteins. Assuming knowledge of native secondary structure, we employ assembly rules gathered from a database of existing structures to enumerate the geometrically possible 3-D arrangements of the constituent helices. We produce a library of possible folds for 25 helical protein cores. In each case the method finds significant numbers of conformations close to the native structure. In addition we assign coordinates to all atoms for 4 of the 25 proteins. In the context of database driven exhaustive enumeration our method performs extremely well, yielding significant percentages of structures (0.02%--82%) within 6A of the native structure. The method's speed and efficiency make it a valuable contribution towards the goal of predicting protein structure.

  14. Photothermal method for in situ microanalysis of the chemical composition of coal samples

    DOEpatents

    Amer, N.M.

    1983-10-25

    Successive minute regions along a scan path on a coal sample are individually analyzed, at a series of different depths if desired, to determine chemical composition including the locations, sizes and distributions of different maceral inclusions. A sequence of infrared light pulses of progressively changing wavelengths is directed into each minute region and a probe light beam is directed along the sample surface adjacent the region. Infrared wavelengths at which strong absorption occurs in the region are identified by detecting the resulting deflections of the probe beam caused by thermally induced index of refraction changes in the air or other medium adjacent the region. The detected peak absorption wavelengths are correlated with known characteristic peak absorption wavelengths of specific coal constituents to identify the composition of each such minute region of the sample. The method enables rapid, convenient and non-destructive analyses of coal specimens to facilitate mining, processing and utilization of coals. 2 figures.

  15. Well fluid isolation and sample apparatus and method

    DOEpatents

    Schalla, Ronald; Smith, Ronald M.; Hall, Stephen H.; Smart, John E.

    1995-01-01

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. A seal may be positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Purged well fluid is stored in a riser above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion.

  16. The classification of the patients with pulmonary diseases using breath air samples spectral analysis

    NASA Astrophysics Data System (ADS)

    Kistenev, Yury V.; Borisov, Alexey V.; Kuzmin, Dmitry A.; Bulanova, Anna A.

    2016-08-01

    Technique of exhaled breath sampling is discussed. The procedure of wavelength auto-calibration is proposed and tested. Comparison of the experimental data with the model absorption spectra of 5% CO2 is conducted. The classification results of three study groups obtained by using support vector machine and principal component analysis methods are presented.

  17. STS 133 Return Samples: Air Quality Aboard Shuttle (STS-133) and International Space Station (ULFS)

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    The toxicological assessments of 2 canisters (mini-GSC or GSCs) from the Shuttle are reported. Analytical methods have not changed from earlier reports. The percent recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 Shuttle GSCs averaged 86, 100, and 87, respectively. Based on the end-of-mission sample, the Shuttle atmosphere was acceptable for human respiration.

  18. Path Sampling Methods for Enzymatic Quantum Particle Transfer Reactions.

    PubMed

    Dzierlenga, M W; Varga, M J; Schwartz, S D

    2016-01-01

    The mechanisms of enzymatic reactions are studied via a host of computational techniques. While previous methods have been used successfully, many fail to incorporate the full dynamical properties of enzymatic systems. This can lead to misleading results in cases where enzyme motion plays a significant role in the reaction coordinate, which is especially relevant in particle transfer reactions where nuclear tunneling may occur. In this chapter, we outline previous methods, as well as discuss newly developed dynamical methods to interrogate mechanisms of enzymatic particle transfer reactions. These new methods allow for the calculation of free energy barriers and kinetic isotope effects (KIEs) with the incorporation of quantum effects through centroid molecular dynamics (CMD) and the full complement of enzyme dynamics through transition path sampling (TPS). Recent work, summarized in this chapter, applied the method for calculation of free energy barriers to reaction in lactate dehydrogenase (LDH) and yeast alcohol dehydrogenase (YADH). We found that tunneling plays an insignificant role in YADH but plays a more significant role in LDH, though not dominant over classical transfer. Additionally, we summarize the application of a TPS algorithm for the calculation of reaction rates in tandem with CMD to calculate the primary H/D KIE of YADH from first principles. We found that the computationally obtained KIE is within the margin of error of experimentally determined KIEs and corresponds to the KIE of particle transfer in the enzyme. These methods provide new ways to investigate enzyme mechanism with the inclusion of protein and quantum dynamics.

  19. Path Sampling Methods for Enzymatic Quantum Particle Transfer Reactions.

    PubMed

    Dzierlenga, M W; Varga, M J; Schwartz, S D

    2016-01-01

    The mechanisms of enzymatic reactions are studied via a host of computational techniques. While previous methods have been used successfully, many fail to incorporate the full dynamical properties of enzymatic systems. This can lead to misleading results in cases where enzyme motion plays a significant role in the reaction coordinate, which is especially relevant in particle transfer reactions where nuclear tunneling may occur. In this chapter, we outline previous methods, as well as discuss newly developed dynamical methods to interrogate mechanisms of enzymatic particle transfer reactions. These new methods allow for the calculation of free energy barriers and kinetic isotope effects (KIEs) with the incorporation of quantum effects through centroid molecular dynamics (CMD) and the full complement of enzyme dynamics through transition path sampling (TPS). Recent work, summarized in this chapter, applied the method for calculation of free energy barriers to reaction in lactate dehydrogenase (LDH) and yeast alcohol dehydrogenase (YADH). We found that tunneling plays an insignificant role in YADH but plays a more significant role in LDH, though not dominant over classical transfer. Additionally, we summarize the application of a TPS algorithm for the calculation of reaction rates in tandem with CMD to calculate the primary H/D KIE of YADH from first principles. We found that the computationally obtained KIE is within the margin of error of experimentally determined KIEs and corresponds to the KIE of particle transfer in the enzyme. These methods provide new ways to investigate enzyme mechanism with the inclusion of protein and quantum dynamics. PMID:27497161

  20. Investigation on the Importance of Fast Air Temperature Measurements in the Sampling Cell of Short-Tube Closed-Path Gas Analyzer for Eddy-Covariance Fluxes

    NASA Astrophysics Data System (ADS)

    Kathilankal, J. C.; Fratini, G.; Burba, G. G.

    2014-12-01

    High-speed, precise gas analyzers used in eddy covariance flux research measure gas content in a known volume, thus essentially measuring gas density. The classical eddy flux equation, however, is based on the dry mole fraction. The relation between dry mole fraction and density is regulated by the ideal gas law and law of partial pressures, and depends on water vapor content, temperature and pressure of air. If the instrument can output precise fast dry mole fraction, the flux processing is significantly simplified and WPL terms accounting for air density fluctuations are no longer required. This will also lead to the reduction in uncertainties associated with the WPL terms. For instruments adopting an open-path design, this method is difficult to use because of complexities with maintaining reliable fast temperature measurements integrated over the entire measuring path, and also because of extraordinary challenges with accurate measurements of fast pressure in the open air flow. For instruments utilizing a traditional long-tube closed-path design, with tube length 1000 or more times the tube diameter, this method can be used when instantaneous fluctuations in the air temperature of the sampled air are effectively dampened, instantaneous pressure fluctuations are regulated or negligible, and water vapor is measured simultaneously with gas, or the sample is dried. For instruments with a short-tube enclosed design, most - but not all - of the temperature fluctuations are attenuated, so calculating unbiased fluxes using fast dry mole fraction output requires high-speed, precise temperature measurements of the air stream inside the cell. In this presentation, authors look at short-term and long-term data sets to assess the importance of high-speed, precise air temperature measurements in the sampling cell of short-tube enclosed gas analyzers. The CO2 and H2O half hourly flux calculations, as well as long-term carbon and water budgets, are examined.