This protocol describes how quality control samples should be handled in the field, and was designed as a quick reference source for the field staff. The protocol describes quality control samples for air-VOCs, air-particles, water samples, house dust, soil, urine, blood, hair, a...
NASA Astrophysics Data System (ADS)
Roubinet, Claire; Moreira, Manuel A.
2018-02-01
Noble gases in oceanic basalts always show the presence in variable proportions of a component having elemental and isotopic compositions that are similar to those of the atmosphere and distinct from the mantle composition. Although this component could be mantle-derived (e.g. subduction of air or seawater-derived noble gases trapped in altered oceanic crust and sediments), it is most often suggested that this air component is added after sample collection and probably during storage at ambient air, although the mechanism remains unknown. In an attempt to reduce this atmospheric component observed in MORBs, four experimental protocols have been followed in this study. These protocols are based on the hypothesis that air can be removed from the samples, as it appears to be sheltered in distinct vesicles compared to those filled with mantle gases. All of the protocols involve a glove box filled with nitrogen, and in certain cases, the samples are stored under primary vacuum (lower than 10-2 mbar) to pump air out or, alternatively, under high pressure of N2 to expel atmospheric noble gases. In all protocols, three components are observed: atmospheric, fractionated atmospheric and magmatic. The fractionated air component seems to be derived from the non-vitreous part of the pillow-lava, which has cooled more slowly. This component is enriched in Ne relative to Ar, reflecting a diffusive process. This contaminant has already been observed in other studies and thus seems to be relatively common. Although it is less visible, unfractionated air has also been detected in some crushing steps, which tends to indicate that despite the experiments, air is still present in the vesicles. This result is surprising, since studies have demonstrated that atmospheric contamination could be limited if samples were stored under nitrogen quickly after their recovery from the seafloor. Thus, the failure of the protocols could be explained by the insufficient duration of these protocols or by the inaccessibility of vesicles filled with air as assessed by (Ballentine and Barfod, 2000).
Microbial Groundwater Sampling Protocol for Fecal-Rich Environments
Harter, Thomas; Watanabe, Naoko; Li, Xunde; Atwill, Edward R; Samuels, William
2014-01-01
Inherently, confined animal farming operations (CAFOs) and other intense fecal-rich environments are potential sources of groundwater contamination by enteric pathogens. The ubiquity of microbial matter poses unique technical challenges in addition to economic constraints when sampling wells in such environments. In this paper, we evaluate a groundwater sampling protocol that relies on extended purging with a portable submersible stainless steel pump and Teflon® tubing as an alternative to equipment sterilization. The protocol allows for collecting a large number of samples quickly, relatively inexpensively, and under field conditions with limited access to capacity for sterilizing equipment. The protocol is tested on CAFO monitoring wells and considers three cross-contamination sources: equipment, wellbore, and ambient air. For the assessment, we use Enterococcus, a ubiquitous fecal indicator bacterium (FIB), in laboratory and field tests with spiked and blank samples, and in an extensive, multi-year field sampling campaign on 17 wells within 2 CAFOs. The assessment shows that extended purging can successfully control for equipment cross-contamination, but also controls for significant contamination of the well-head, within the well casing and within the immediate aquifer vicinity of the well-screen. Importantly, our tests further indicate that Enterococcus is frequently entrained in water samples when exposed to ambient air at a CAFO during sample collection. Wellbore and air contamination pose separate challenges in the design of groundwater monitoring strategies on CAFOs that are not addressed by equipment sterilization, but require adequate QA/QC procedures and can be addressed by the proposed sampling strategy. PMID:24903186
DEVELOPMENT OF A SUB-SLAB AIR SAMPLING PROTOCOL TO SUPPORT ASSESSMENT OF VAPOR INTRUSION
The primary purpose of this research effort is to develop a methodology for sub-slab sampling to support the EPA guidance and vapor intrusion investigations after vapor intrusion has been established at a site. Methodologies for sub-slab air sampling are currently lacking in ref...
Protocol for Detection of Bacillus anthracis in Environmental Samples
This pProtocol Method describes proceduresintended for the analyses of swabs, wipes, Sponge-Sticks, vacuum socks and filters, air filters, drinking water, and decontamination waste water for Bacillus anthracis spores.
Tirali, R E; Celik, C; Arhun, N; Berk, G; Cehreli, S B
2013-01-01
The purpose of this study was to investigate the effects of different pretreatment protocols along with different bonding agents on the microleakage of a fissure sealant material. A total of 144 freshly extracted noncarious human third molars were used The teeth were randomly assigned into three groups with respect to the pretreatment protocol employed: A. Air Abrasion B. Er,Cr:YSGG laser C. No pretreatment (Control). In each group specimens were further subjected to one of the following procedures before application of the sealant: 1. %36 Phosphoric acid-etch (AE) (DeTrey Conditioner 36/Denstply, UK) 2.AE+Prime&Bond NT (Dentsply, UK) 3. Clearfil S3 Bond (Kuraray, Japan) 4. Clearfil SE Bond (Kuraray, Japan). All teeth were sealed with the same fissure sealant material (Conseal F/SDI, Australia). Sealed teeth were further subjected to thermocycling, dye penetration test, sectioning and quantitative image analysis. Statistical evaluation of the microleakage data was performed with two way independent ANOVA and multiple comparisons test at p = 0.05. For qualitative evaluation 2 samples from each group were examined under Scanning Electron Microscopy. Microleakage was affected by both the type of pretreatment and the subsequent bonding protocols employed (p < 0.05). Overall, the highest (Mean = 0.36 mm) and lowest (Mean = 0.06 mm) microleakage values were observed in samples with unpretreated enamel sealed by S3+Conseal F and samples with laser pretreated enamel sealed by Acid Etch+Prime&-Bond+Conseal F protocols, respectively (p < 0.05). In the acid-etch group samples pretreated with laser yielded in slightly lower microleakage scores when compared with unpretreated samples and samples pretreated with air abrasion but the statistical significance was not important (p = 0,179). Similarly, when bonding agent is applied following acid-etching procedure, microleakage scores were not affected from pretreatment protocol (p = 0,615) (intact enamel/laser or air-abrasion). For both all-in one and two step self etch adhesive systems, unpretreated samples demonstrated the highest microleakage scores. For the groups in which bonding agent was utilized, pretreatments did not effected microleakage. Both the tested pretreatment protocols and adhesive procedures had different effects on the sealing properties of Conseal F in permanent tooth enamel.
NASA Astrophysics Data System (ADS)
Padgett, D.
2016-12-01
Tennessee State University (TSU) is among seven partner institutions in the NASA-funded project "Mission Earth: Fusing Global Learning and Observations to Benefit the Environment (GLOBE) with NASA Assets to Build Systemic Innovation in STEM Education." The primary objective at the TSU site is to expose high school students from racial and ethnic groups traditionally underrepresented in STEM to atmospheric science and physical systems associated with climate change. Currently, undergraduate students enrolled in TSU's urban and physical courses develop lessons for high school students focused upon the analysis of global warming phenomena and related extreme weather events. The GLOBE Atmosphere Protocols are emphasized in exercises focused upon the urban heat island (UHI) phenomenon and air quality measurements. Pre-service teachers at TSU, and in-service teachers at four local high schools are being certified in the Atmosphere Protocols. Precipitation, ambient air temperature, surface temperature and other data are collected at the schools through a collaborative learning effort among the high school students, TSU undergraduates, and high school teachers. Data collected and recorded manually in the field are compared to each school's automated Weatherbug station measurements. Students and teachers engage in analysis of NASA imagery as part of the GLOBE Surface Temperature Protocol. At off-campus locations, US Clean Air Act (CAA) criteria air pollutant and Toxic Release Inventory (TRI) air pollutant sampling is being conducted in community-based participatory research (CBPR) format. Students partner with non-profit environmental organizations. Data collected using low-cost air sampling devices is being compared with readings from government air monitors. The GLOBE Aerosols Protocol is used in comparative assessments with air sampling results. Project deliverables include four new GLOBE schools, the enrollment of which is nearly entirely comprised of students underrepresented in STEM. A model for service learning activities with GLOBE to increase underrepresented groups participation in STEM is a second deliverable. A third deliverable, a comprehensive citizen science guidebook for grassroots level air quality assessment, is being developed for wide distribution.
Detection of the urban release of a bacillus anthracis simulant by air sampling.
Garza, Alexander G; Van Cuyk, Sheila M; Brown, Michael J; Omberg, Kristin M
2014-01-01
In 2005 and 2009, the Pentagon Force Protection Agency (PFPA) staged deliberate releases of a commercially available organic pesticide containing Bacillus amyloliquefaciens to evaluate PFPA's biothreat response protocols. In concert with, but independent of, these releases, the Department of Homeland Security sponsored experiments to evaluate the efficacy of commonly employed air and surface sampling techniques for detection of an aerosolized biological agent. High-volume air samplers were placed in the expected downwind plume, and samples were collected before, during, and after the releases. Environmental surface and personal air samples were collected in the vicinity of the high-volume air samplers hours after the plume had dispersed. The results indicate it is feasible to detect the release of a biological agent in an urban area both during and after the release of a biological agent using high-volume air and environmental sampling techniques.
2014-07-01
Analyzer TCE Trichloroethene USEPA U.S. Environmental Protection Agency V- PDB Vienna - Pee Dee Belemnite V-SMOW Vienna – Standard Mean Ocean Water ... PDB ) for carbon, Standard Mean Ocean Chloride (SMOC) for chlorine, and Vienna-Standard Mean Ocean Water (V-SMOW) for hydrogen. CSIA Protocol for...7 3.3 INDOOR AIR SAMPLING LOCATIONS ............................................................ 8 3.4 COLLECTION OF WATER SAMPLES
Libert, Xavier; Packeu, Ann; Bureau, Fabrice; Roosens, Nancy H; De Keersmaecker, Sigrid C J
2017-01-01
Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.
Lichen elements as pollution indicators: evaluation of methods for large monitoring programmes
Susan Will-Wolf; Sarah Jovan; Michael C. Amacher
2017-01-01
Lichen element content is a reliable indicator for relative air pollution load in research and monitoring programmes requiring both efficiency and representation of many sites. We tested the value of costly rigorous field and handling protocols for sample element analysis using five lichen species. No relaxation of rigour was supported; four relaxed protocols generated...
[Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].
Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira
2014-01-01
To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.
The atmospheric inventory of Xenon and noble cases in shales The plastic bag experiment
NASA Technical Reports Server (NTRS)
Bernatowicz, T. J.; Podosek, F. A.; Honda, M.; Kramer, F. E.
1984-01-01
A novel trapped gas analysis protocol is applied to five shales in which the samples are sealed in air to eliminate the possibility of gas loss in the preanalysis laboratory vacuum exposure of a conventional protocol. The test is aimed at a determination concerning the hypothesis that atmospheric noble gases occur in the same proportion as planetary gases in meteorites, and that the factor-of-23 deficiency of air Xe relative to planetary Xe is made up by Xe stored in shales or other sedimentary rocks. The results obtained do not support the shale hypothesis.
Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira
2017-06-22
Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.
Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira
2017-01-01
Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202
Buttner, M P; Stetzenbach, L D
1993-01-01
Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150
Protocol for determining bull trout presence
Peterson, James; Dunham, Jason B.; Howell, Philip; Thurow, Russell; Bonar, Scott
2002-01-01
The Western Division of the American Fisheries Society was requested to develop protocols for determining presence/absence and potential habitat suitability for bull trout. The general approach adopted is similar to the process for the marbled murrelet, whereby interim guidelines are initially used, and the protocols are subsequently refined as data are collected. Current data were considered inadequate to precisely identify suitable habitat but could be useful in stratifying sampling units for presence/absence surveys. The presence/absence protocol builds on previous approaches (Hillman and Platts 1993; Bonar et al. 1997), except it uses the variation in observed bull trout densities instead of a minimum threshold density and adjusts for measured differences in sampling efficiency due to gear types and habitat characteristics. The protocol consists of: 1. recommended sample sizes with 80% and 95% detection probabilities for juvenile and resident adult bull trout for day and night snorkeling and electrofishing adjusted for varying habitat characteristics for 50m and 100m sampling units, 2. sampling design considerations, including possible habitat characteristics for stratification, 3. habitat variables to be measured in the sampling units, and 3. guidelines for training sampling crews. Criteria for habitat strata consist of coarse, watershed-scale characteristics (e.g., mean annual air temperature) and fine-scale, reach and habitat-specific features (e.g., water temperature, channel width). The protocols will be revised in the future using data from ongoing presence/absence surveys, additional research on sampling efficiencies, and development of models of habitat/species occurrence.
Detection of respiratory viruses on air filters from aircraft.
Korves, T M; Johnson, D; Jones, B W; Watson, J; Wolk, D M; Hwang, G M
2011-09-01
To evaluate the feasibility of identifying viruses from aircraft cabin air, we evaluated whether respiratory viruses trapped by commercial aircraft air filters can be extracted and detected using a multiplex PCR, bead-based assay. The ResPlex II assay was first tested for its ability to detect inactivated viruses applied to new filter material; all 18 applications of virus at a high concentration were detected. The ResPlex II assay was then used to test for 18 respiratory viruses on 48 used air filter samples from commercial aircraft. Three samples tested positive for viruses, and three viruses were detected: rhinovirus, influenza A and influenza B. For 33 of 48 samples, internal PCR controls performed suboptimally, suggesting sample matrix effect. In some cases, influenza and rhinovirus RNA can be detected on aircraft air filters, even more than 10 days after the filters were removed from aircraft. With protocol modifications to overcome PCR inhibition, air filter sampling and the ResPlex II assay could be used to characterize viruses in aircraft cabin air. Information about viruses in aircraft could support public health measures to reduce disease transmission within aircraft and between cities. © The MITRE corporation. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
Muller, Matthew D.; Gao, Zhaohui; Drew, Rachel C.; Herr, Michael D.; Leuenberger, Urs A.
2011-01-01
The effects of cold air inhalation and isometric exercise on coronary blood flow are currently unknown, despite the fact that both cold air and acute exertion trigger angina in clinical populations. In this study, we used transthoracic Doppler echocardiography to measure coronary blood flow velocity (CBV; left anterior descending coronary artery) and myocardial function during cold air inhalation and handgrip exercise. Ten young healthy subjects underwent the following protocols: 5 min of inhaling cold air (cold air protocol), 5 min of inhaling thermoneutral air (sham protocol), 2 min of isometric handgrip at 30% of maximal voluntary contraction (grip protocol), and 5 min of isometric handgrip at 30% maximal voluntary contraction while breathing cold air (cold + grip protocol). Heart rate, blood pressure, inspired air temperature, CBV, myocardial function (tissue Doppler imaging), O2 saturation, and pulmonary function were measured. The rate-pressure product (RPP) was used as an index of myocardial O2 demand, whereas CBV was used as an index of myocardial O2 supply. Compared with the sham protocol, the cold air protocol caused a significantly higher RPP, but there was a significant reduction in CBV. The cold + grip protocol caused a significantly greater increase in RPP compared with the grip protocol (P = 0.045), but the increase in CBV was significantly less (P = 0.039). However, myocardial function was not impaired during the cold + grip protocol relative to the grip protocol alone. Collectively, these data indicate that there is a supply-demand mismatch in the coronary vascular bed when cold ambient air is breathed during acute exertion but myocardial function is preserved, suggesting an adequate redistribution of blood flow. PMID:21940852
A protocol for collecting environmental DNA samples from streams
Kellie J. Carim; Kevin S. McKelvey; Michael K. Young; Taylor M. Wilcox; Michael K. Schwartz
2016-01-01
Environmental DNA (eDNA) is DNA that has been released by an organism into its environment, such that the DNA can be found in air, water, or soil. In aquatic systems, eDNA has been shown to provide a sampling approach that is more sensitive for detecting target organisms faster, and less expensively than previous approaches. However, eDNA needs to be sampled in a...
Protocol Improvements for Low Concentration DNA-Based Bioaerosol Sampling and Analysis
Ng, Chun Kiat; Miller, Dana; Cao, Bin
2015-01-01
Introduction As bioaerosol research attracts increasing attention, there is a need for additional efforts that focus on method development to deal with different environmental samples. Bioaerosol environmental samples typically have very low biomass concentrations in the air, which often leaves researchers with limited options in choosing the downstream analysis steps, especially when culture-independent methods are intended. Objectives This study investigates the impacts of three important factors that can influence the performance of culture-independent DNA-based analysis in dealing with bioaerosol environmental samples engaged in this study. The factors are: 1) enhanced high temperature sonication during DNA extraction; 2) effect of sampling duration on DNA recoverability; and 3) an alternative method for concentrating composite samples. In this study, DNA extracted from samples was analysed using the Qubit fluorometer (for direct total DNA measurement) and quantitative polymerase chain reaction (qPCR). Results and Findings The findings suggest that additional lysis from high temperature sonication is crucial: DNA yields from both high and low biomass samples increased up to 600% when the protocol included 30-min sonication at 65°C. Long air sampling duration on a filter media was shown to have a negative impact on DNA recoverability with up to 98% of DNA lost over a 20-h sampling period. Pooling DNA from separate samples during extraction was proven to be feasible with margins of error below 30%. PMID:26619279
Viegas, Carla; Faria, Tiago; Pacífico, Cátia; Dos Santos, Mateus; Monteiro, Ana; Lança, Carla; Carolino, Elisabete; Viegas, Susana; Cabo Verde, Sandra
2017-01-01
The aim of this work was to assess the microbiota (fungi and bacteria) and particulate matter in optical shops, contributing to a specific protocol to ensure a proper assessment. Air samples were collected through an impaction method. Surface and equipment swab samples were also collected side-by-side. Measurements of particulate matter were performed using portable direct-reading equipment. A walkthrough survey and checklist was also applied in each shop. Regarding air sampling, eight of the 13 shops analysed were above the legal requirement and 10 from the 26 surfaces samples were overloaded. In three out of the 13 shops fungal contamination in the analysed equipment was not detected. The bacteria air load was above the threshold in one of the 13 analysed shops. However, bacterial counts were detected in all sampled equipment. Fungi and bacteria air load suggested to be influencing all of the other surface and equipment samples. These results reinforce the need to improve air quality, not only to comply with the legal requirements, but also to ensure proper hygienic conditions. Public health intervention is needed to assure the quality and safety of the rooms and equipment in optical shops that perform health interventions in patients. PMID:28505144
USDA Forest Service national protocols for sampling air pollution-sensitive waters
T. J. Sullivan
2012-01-01
The first step in designing a surface water sampling program is identifying one or more problems or questions that require information on water quality. Common water quality problems include nutrient enrichment (from a variety of causes), effects of atmospheric deposition (acidification, eutrophication, toxicity), and effects of major disturbances such as fire or pest...
AIR DRYING AND PRETREATMENT EFFECTS ON SOIL SULFATE SORPTION
Drying, freezing, and refrigeration are commonly employed to facilitate the handling and storage of soil samples on which chemical, biological and physical analyses are to be performed. hese laboratory protocol have the potential to alter soil chemical characteristics and may res...
Lever, Mark A.; Torti, Andrea; Eickenbusch, Philip; Michaud, Alexander B.; Šantl-Temkiv, Tina; Jørgensen, Bo Barker
2015-01-01
A method for the extraction of nucleic acids from a wide range of environmental samples was developed. This method consists of several modules, which can be individually modified to maximize yields in extractions of DNA and RNA or separations of DNA pools. Modules were designed based on elaborate tests, in which permutations of all nucleic acid extraction steps were compared. The final modular protocol is suitable for extractions from igneous rock, air, water, and sediments. Sediments range from high-biomass, organic rich coastal samples to samples from the most oligotrophic region of the world's oceans and the deepest borehole ever studied by scientific ocean drilling. Extraction yields of DNA and RNA are higher than with widely used commercial kits, indicating an advantage to optimizing extraction procedures to match specific sample characteristics. The ability to separate soluble extracellular DNA pools without cell lysis from intracellular and particle-complexed DNA pools may enable new insights into the cycling and preservation of DNA in environmental samples in the future. A general protocol is outlined, along with recommendations for optimizing this general protocol for specific sample types and research goals. PMID:26042110
Radiological Air Sampling. Protocol Development for the Canadian Forces
2003-03-01
samplers trap these airborne radon daughters . Because radon is ubiquitous, all air samplers will catch these radioactive radon daughters in the...environment is complicated because all air sampler filters are radioactive because of the radon daughters . ’Actually, D will often depend on the isotope that...simply as "radon". 2 DRDC Ottawa TM 2003-149 -28 - 22 R_ 211p0 214pb 3.8 d 3.0 m 27 m 214Bi 210TI Radon Daughters 20 m ŕ.3 m (Uranium Decay Chain
Luyckx, K; Dewulf, J; Van Weyenberg, S; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K
2015-04-01
Cleaning and disinfection of the broiler stable environment is an essential part of farm hygiene management. Adequate cleaning and disinfection is essential for prevention and control of animal diseases and zoonoses. The goal of this study was to shed light on the dynamics of microbiological and non-microbiological parameters during the successive steps of cleaning and disinfection and to select the most suitable sampling methods and parameters to evaluate cleaning and disinfection in broiler houses. The effectiveness of cleaning and disinfection protocols was measured in six broiler houses on two farms through visual inspection, adenosine triphosphate hygiene monitoring and microbiological analyses. Samples were taken at three time points: 1) before cleaning, 2) after cleaning, and 3) after disinfection. Before cleaning and after disinfection, air samples were taken in addition to agar contact plates and swab samples taken from various sampling points for enumeration of total aerobic flora, Enterococcus spp., and Escherichia coli and the detection of E. coli and Salmonella. After cleaning, air samples, swab samples, and adenosine triphosphate swabs were taken and a visual score was also assigned for each sampling point. The mean total aerobic flora determined by swab samples decreased from 7.7±1.4 to 5.7±1.2 log CFU/625 cm2 after cleaning and to 4.2±1.6 log CFU/625 cm2 after disinfection. Agar contact plates were used as the standard for evaluating cleaning and disinfection, but in this study they were found to be less suitable than swabs for enumeration. In addition to measuring total aerobic flora, Enterococcus spp. seemed to be a better hygiene indicator to evaluate cleaning and disinfection protocols than E. coli. All stables were Salmonella negative, but the detection of its indicator organism E. coli provided additional information for evaluating cleaning and disinfection protocols. Adenosine triphosphate analyses gave additional information about the hygiene level of the different sampling points. © 2015 Poultry Science Association Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W; Benton, Nathanael; Burns, Patrick
Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: High-efficiency/variable speed drive (VSD) compressormore » replacing modulating, load/unload, or constant-speed compressor; and Compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.« less
Dynamics of airborne fungal populations in a large office building
NASA Technical Reports Server (NTRS)
Burge, H. A.; Pierson, D. L.; Groves, T. O.; Strawn, K. F.; Mishra, S. K.
2000-01-01
The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings.
RESEARCH BRIEFING ON DEVELOPMENT OF A SUB-SLAB AIR SAMPLING PROTOCOL
Vapor intrusion is defined as the migration of volatile organic compounds (VOCs) into occupied buildings from contaminated soil or ground water. EPA recently developed guidance to facilitate assessment of vapor intrusion at sites regulated by RCRA and CERCLA. The EPA guidance e...
A simplified field protocol for genetic sampling of birds using buccal swabs
Vilstrup, Julia T.; Mullins, Thomas D.; Miller, Mark P.; McDearman, Will; Walters, Jeffrey R.; Haig, Susan M.
2018-01-01
DNA sampling is an essential prerequisite for conducting population genetic studies. For many years, blood sampling has been the preferred method for obtaining DNA in birds because of their nucleated red blood cells. Nonetheless, use of buccal swabs has been gaining favor because they are less invasive yet still yield adequate amounts of DNA for amplifying mitochondrial and nuclear markers; however, buccal swab protocols often include steps (e.g., extended air-drying and storage under frozen conditions) not easily adapted to field settings. Furthermore, commercial extraction kits and swabs for buccal sampling can be expensive for large population studies. We therefore developed an efficient, cost-effective, and field-friendly protocol for sampling wild birds after comparing DNA yield among 3 inexpensive buccal swab types (2 with foam tips and 1 with a cotton tip). Extraction and amplification success was high (100% and 97.2% respectively) using inexpensive generic swabs. We found foam-tipped swabs provided higher DNA yields than cotton-tipped swabs. We further determined that omitting a drying step and storing swabs in Longmire buffer increased efficiency in the field while still yielding sufficient amounts of DNA for detailed population genetic studies using mitochondrial and nuclear markers. This new field protocol allows time- and cost-effective DNA sampling of juveniles or small-bodied birds for which drawing blood may cause excessive stress to birds and technicians alike.
Comparing the biocidal properties of non-thermal plasma sources by reference protocol
NASA Astrophysics Data System (ADS)
Khun, Josef; Jirešová, Jana; Kujalová, Lucie; Hozák, Pavel; Scholtz, Vladimír
2017-10-01
The previously proposed reference protocol enabling easy comparison of biocidal properties of different non-thermal plasma sources has been followed and discussed. For inactivation tests the reference protocol has used spores of Gram positive bacterium Bacillus subtilis (ATCC 6633) deposited on a polycarbonate membrane as reference sample. In this work, biocidal properties of a negative glow corona, positive streamer corona, positive transient spark and cometary discharges are being compared in both open air and closed apparatus. Despite the total number of bacteria surviving 1 h exposure has decreased by up to 7 orders in closed apparatus, in open one, only weak inhibition bactericidal effect has been observed.
Evaluation of a Biological Pathogen Decontamination Protocol for Animal Feed Mills.
Huss, Anne R; Cochrane, Roger A; Deliephan, Aiswariya; Stark, Charles R; Jones, Cassandra K
2015-09-01
Animal feed and ingredients are potential vectors of pathogenic bacteria. Contaminated ingredients can contaminate facility equipment, leading to cross-contamination of other products. This experiment was conducted to evaluate a standardized protocol for decontamination of an animal feed manufacturing facility using Enterococcus faecium (ATCC 31282) as an indicator. A pelleted swine diet inoculated with E. faecium was manufactured, and environmental samples (swabs, replicate organism detection and counting plates, and air samples) were collected (i) before inoculation (baseline data), (ii) after production of inoculated feed, (iii) after physical removal of organic material using pressurized air, (iv) after application of a chemical sanitizer containing a quaternary ammonium-glutaraldehyde blend, (v) after application of a chemical sanitizer containing sodium hypochlorite, (vi) after facility heat-up to 60 8 C for 24 h, (vii) for 48 h, and (viii) for 72 h. Air samples collected outside the facility confirmed pathogen containment; E. faecium levels were equal to or lower than baseline levels at each sample location. The decontamination step and its associated interactions were the only variables that affected E. faecium incidence (P < 0.0001 versus P > 0.22). After production of the inoculated diet, 85.7% of environmental samples were positive for E. faecium. Physical cleaning of equipment had no effect on contamination (P = 0.32). Chemical cleaning with a quaternary ammonium-glutaraldehyde blend and sodium hypochlorite each significantly reduced E. faecium contamination (P < 0.0001) to 28.6 and 2.4% of tested surfaces, respectively. All samples were negative for E. faecium after 48 h of heating. Both wet chemical cleaning and facility heating but not physical cleaning resulted in substantial E. faecium decontamination. These results confirmed both successful containment and decontamination of biological pathogens in the tested pilot-scale feed mill.
Near-infrared spectroscopy (NIRS) as a tool to monitor exhaust air from poultry operations.
Druckenmüller, Katharina; Günther, Klaus; Elbers, Gereon
2018-07-15
Intensive poultry operation systems emit a considerable volume of inorganic and organic matter in the surrounding environment. Monitoring cleaning properties of exhaust air cleaning systems and to detect small but significant changes in emission characteristics during a fattening cycle is important for both emission and fattening process control. In the present study, we evaluated the potential of near-infrared spectroscopy (NIRS) combined with chemometric techniques as a monitoring tool of exhaust air from poultry operation systems. To generate a high-quality data set for evaluation, the exhaust air of two poultry houses was sampled by applying state-of-the-art filter sampling protocols. The two stables were identical except for one crucial difference, the presence or absence of an exhaust air cleaning system. In total, twenty-one exhaust air samples were collected at the two sites to monitor spectral differences caused by the cleaning device, and to follow changes in exhaust air characteristics during a fattening period. The total dust load was analyzed by gravimetric determination and included as a response variable in multivariate data analysis. The filter samples were directly measured with NIR spectroscopy. Principal component analysis (PCA), linear discriminant analysis (LDA), and factor analysis (FA) were effective in classifying the NIR exhaust air spectra according to fattening day and origin. The results indicate that the dust load and the composition of exhaust air (inorganic or organic matter) substantially influence the NIR spectral patterns. In conclusion, NIR spectroscopy as a tool is a promising and very rapid way to detect differences between exhaust air samples based on still not clearly defined circumstances triggered during a fattening period and the availability of an exhaust air cleaning system. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Brunelli, Alessandro; Salati, Michele; Refai, Majed; Di Nunzio, Luca; Xiumé, Francesco; Sabbatini, Armando
2010-01-01
The objective of this randomised trial was to assess the effectiveness of a new fast-track chest tube removal protocol taking advantage of digital monitoring of air leak compared to a traditional protocol using visual and subjective assessment of air leak (bubbles). One hundred and sixty-six patients submitted to pulmonary lobectomy for lung cancer were randomised in two groups with different chest tube removal protocols: (1) in the new protocol, chest tube was removed based on digitally recorded measurements of air leak flow; (2) in the traditional protocol, the chest tube removal was based on an instantaneous assessment of air leak during daily rounds. The two groups were compared in terms of chest tube duration, hospital stay and costs. The two groups were well matched for several preoperative and operative variables. Compared to the traditional protocol, the new digital recording protocol showed mean reductions in chest tube duration (p=0.0007), hospital stay (p=0.007) of 0.9 day, and a mean cost saving of euro 476 per patient (p=0.008). In the new chest tube removal protocol, 51% of patients had their chest tube removed by the second postoperative day versus only 12% of those in the traditional protocol. The application of a chest tube removal protocol using a digital drainage unit featuring a continuous recording of air leak was safe and cost effective. Although future studies are warranted to confirm these results in other settings, the use of this new protocol is now routinely applied in our practice. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
1988-12-01
and do not refer to monitoring zones at McClellSn AFB. b Priority poLutant metals analyses also included U.S. EPA Methods 206.2, 245.1 and 270.2. EW a...sampling protocol, and the laboratory is audited routinely. Therefore, no corrective action other than good training and supervision is necessary. The same
Quality assured measurements of animal building emissions: odor concentrations.
Jacobson, Larry D; Hetchler, Brian P; Schmidt, David R; Nicolai, Richard E; Heber, Albert J; Ni, Ji-Qin; Hoff, Steven J; Koziel, Jacek A; Zhang, Yuanhui; Beasley, David B; Parker, David B
2008-06-01
Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC'SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 degrees C and 1 atm) building airflow rates.
Dunn, Kevin H.; Tsai, Candace Su-Jung; Woskie, Susan R.; Bennett, James S.; Garcia, Alberto; Ellenbecker, Michael J.
2015-01-01
The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 feet/minute) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust air flows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity. PMID:25175285
Song, Jing; Wei, Ling; Ma, Ying; Tian, Ning; Huang, Shi Yun; Dai, Yin Mei; Zhao, Li Hong; Kong, Yuan Yuan
2017-01-01
Introduction The association between early exposure to ambient air pollution and adverse pregnancy outcomes in China is unclear. This study will assess the risk of early-life exposure to air pollutants in Beijing and explore the viability of 8-hydroxydeoxyguanosine (8-OHdG) as a biological indicator to assess oxidative stress induced by early-life exposure to air pollution. Methods and analysis Here, 2500 women with singleton pregnancies and their infants will be recruited from the Beijing Obstetrics and Gynecology Hospital. We will collect nine types of biological samples, including maternal serum, urine, placental tissue, umbilical cord tissue and umbilical cord blood during all three trimesters. The air pollution data (particulate matter (PM)2.5, PM10 and similar factors) will be recorded at official fixed-site monitoring stations closest to where the pregnant women live. We plan to assess the effect of air pollutants on adverse pregnancy outcomes and infant respiratory and circulatory disease using Cox regression and competitive risk analysis and explore possible critical windows of exposure during pregnancy using daily pollutant concentrations averaged over various periods of pregnancy combined with individual activity and physiological parameters. Maternal and umbilical cord blood samples (1000 samples) will be randomly selected for 8-OHdG assays to assess the correlation between exposures to air pollutants and oxidative stress. We will determine whether air pollutant exposure or 8-OHdG levels are associated with adverse pregnancy outcomes. SPSS and SAS statistical software will be used for data analysis. Cox regression and competing risk analysis will be used to compute the HR and population attributable risk. Ethics and dissemination This research protocol has already been approved by the Medical Ethics Committee of Beijing Obstetrics and Gynecology Hospital. Written informed consent will be obtained from all study participants prior to enrolment. The results will be published in peer-reviewed journals or disseminated through conference presentations. Trial registration number This study has been registered in WHO International Clinical Trial Register—Chinese Clinical Trial Registry under registration number ChiCTR-ROC-16010181 (http :// www.chictr.org.cn / showproj.aspx ?proj=17328). PMID:28871018
1980-11-01
hours, then overnight in a refrigerator or cold room at 40C. Fol- lowing clot retraction , the serum may be decanted and spun, or the whole sample spun...Drogram. The SIMP programme may involve one or all of the following: collection of post nasal swabs, blood sera samples, air samples and surface samples...outlined in para 16. 16. Culturing of Swabs Swabs shall be placed on Columbia Blood Agar (4 or 5% sheep RBC’s) supplemented with IsoVitalex (Baltimore
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
...-AQ06 Protocol Gas Verification Program and Minimum Competency Requirements for Air Emission Testing... correct certain portions of the Protocol Gas Verification Program and Minimum Competency Requirements for... final rule that amends the Agency's Protocol Gas Verification Program (PGVP) and the minimum competency...
Guide to monitoring smoke exposure of wildland firefighters.
Tim E. Reinhardt; Roger D. Ottmar; Michael J. Hallett
1999-01-01
Fire managers and safety officers concerned with smoke exposure among fire crews can use electronic carbon monoxide (CO) monitors to track and prevent overexposure to smoke. Commonly referred to as dosimeters, these lightweight instruments measure the concentration of CO in the air the firefighter's breathe. This guide outlines the protocol developed for sampling...
EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards
EPA's air monitoring regulations require the use of Protocol Gases to set air pollution monitors. This protocol balances the government's need for accuracy with the producers' need for flexibility, low cost, and minimum external oversight.
How smoke-free laws improve air quality: A global study of Irish pubs
Carpenter, Carrie M.; Travers, Mark J.; Cummings, K. Michael; Hyland, Andrew; Mulcahy, Maurice; Clancy, Luke
2009-01-01
Introduction The present study examined indoor air quality in a global sample of smoke-free and smoking-permitted Irish pubs. We hypothesized that levels of respirable suspended particles, an important marker of secondhand smoke, would be significantly lower in smoke-free Irish pubs than in pubs that allowed smoking. Methods Indoor air quality was assessed in 128 Irish pubs in 15 countries between 21 January 2004 and 10 March 2006. Air quality was evaluated using an aerosol monitor, which measures the level of fine particle (PM2.5) pollution in the air. A standard measurement protocol was used by data collectors across study sites. Results Overall, the level of air pollution inside smoke-free Irish pubs was 93% lower than the level found in pubs where smoking was permitted. Discussion Levels of indoor air pollution can be massively reduced by enacting and enforcing smoke-free policies. PMID:19380381
How smoke-free laws improve air quality: a global study of Irish pubs.
Connolly, Gregory N; Carpenter, Carrie M; Travers, Mark J; Cummings, K Michael; Hyland, Andrew; Mulcahy, Maurice; Clancy, Luke
2009-06-01
The present study examined indoor air quality in a global sample of smoke-free and smoking-permitted Irish pubs. We hypothesized that levels of respirable suspended particles, an important marker of secondhand smoke, would be significantly lower in smoke-free Irish pubs than in pubs that allowed smoking. Indoor air quality was assessed in 128 Irish pubs in 15 countries between 21 January 2004 and 10 March 2006. Air quality was evaluated using an aerosol monitor, which measures the level of fine particle (PM(2.5)) pollution in the air. A standard measurement protocol was used by data collectors across study sites. Overall, the level of air pollution inside smoke-free Irish pubs was 93% lower than the level found in pubs where smoking was permitted. Levels of indoor air pollution can be massively reduced by enacting and enforcing smoke-free policies.
Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J
2014-01-01
The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity.
A statistical model for characterizing common air pollutants in air-conditioned offices
NASA Astrophysics Data System (ADS)
Wong, L. T.; Mui, K. W.; Hui, P. S.
Maintaining acceptable indoor air quality (IAQ) for a healthy environment is of primary concern, policymakers have developed different strategies to address the performance of it based on proper assessment methodologies and monitoring plans. It could be cost prohibitive to sample all toxic pollutants in a building. In search of a more manageable number of parameters for cost-effective IAQ assessment, this study investigated the probable correlations among the 12 indoor environmental parameters listed in the IAQ certification scheme of the Hong Kong Environment Protection Department (HKEPD) in 422 Hong Kong offices. These 12 parameters consists of nine indoor air pollutants: carbon dioxide (CO 2), carbon monoxide (CO), respirable suspended particulates (RSP), nitrogen dioxide (NO 2), ozone (O 3), formaldehyde (HCHO), total volatile organic compounds (TVOC), radon (Rn), airborne bacteria count (ABC); and three thermal comfort parameters: temperature ( T), relative humidity (RH) and air velocity ( V). The relative importance of the correlations derived, from largest to smallest loadings, was ABC, Rn, CO, RH, RSP, CO 2, TVOC, O 3, T, V, NO 2 and HCHO. Together with the mathematical expressions derived, an alternative sampling protocol for IAQ assessment with the three 'most representative and independent' parameters namely RSP, CO 2 and TVOC measured in an office environment was proposed. The model validity was verified with on site measurements from 43 other offices in Hong Kong. The measured CO 2, RSP and TVOC concentrations were used to predict the probable levels of the other nine parameters and good agreement was found between the predictions and measurements. This simplified protocol provides an easy tool for performing IAQ monitoring in workplaces and will be useful for determining appropriate mitigation measures to finally honor the certification scheme in a cost-effective way.
Inactivation of RNA Viruses by Gamma Irradiation: A Study on Mitigating Factors
Hume, Adam J.; Ames, Joshua; Rennick, Linda J.; Duprex, W. Paul; Marzi, Andrea; Tonkiss, John; Mühlberger, Elke
2016-01-01
Effective inactivation of biosafety level 4 (BSL-4) pathogens is vital in order to study these agents safely. Gamma irradiation is a commonly used method for the inactivation of BSL-4 viruses, which among other advantages, facilitates the study of inactivated yet morphologically intact virions. The reported values for susceptibility of viruses to inactivation by gamma irradiation are sometimes inconsistent, likely due to differences in experimental protocols. We analyzed the effects of common sample attributes on the inactivation of a recombinant vesicular stomatitis virus expressing the Zaire ebolavirus glycoprotein and green fluorescent protein. Using this surrogate virus, we found that sample volume and protein content of the sample modulated viral inactivation by gamma irradiation but that air volume within the sample container and the addition of external disinfectant surrounding the sample did not. These data identify several factors which alter viral susceptibility to inactivation and highlight the usefulness of lower biosafety level surrogate viruses for such studies. Our results underscore the need to validate inactivation protocols of BSL-4 pathogens using “worst-case scenario” procedures to ensure complete sample inactivation. PMID:27455307
Song, Jing; Chen, Yi; Wei, Ling; Ma, Ying; Tian, Ning; Huang, Shi Yun; Dai, Yin Mei; Zhao, Li Hong; Kong, Yuan Yuan
2017-09-03
The association between early exposure to ambient air pollution and adverse pregnancy outcomes in China is unclear. This study will assess the risk of early-life exposure to air pollutants in Beijing and explore the viability of 8-hydroxydeoxyguanosine (8-OHdG) as a biological indicator to assess oxidative stress induced by early-life exposure to air pollution. Here , 2500 women with singleton pregnancies and their infants will be recruited from the Beijing Obstetrics and Gynecology Hospital. We will collect nine types of biological samples, including maternal serum, urine, placental tissue, umbilical cord tissue and umbilical cord blood during all three trimesters. The air pollution data (particulate matter (PM)2.5, PM10 and similar factors) will be recorded at official fixed-site monitoring stations closest to where the pregnant women live. We plan to assess the effect of air pollutants on adverse pregnancy outcomes and infant respiratory and circulatory disease using Cox regression and competitive risk analysis and explore possible critical windows of exposure during pregnancy using daily pollutant concentrations averaged over various periods of pregnancy combined with individual activity and physiological parameters. Maternal and umbilical cord blood samples (1000 samples) will be randomly selected for 8-OHdG assays to assess the correlation between exposures to air pollutants and oxidative stress. We will determine whether air pollutant exposure or 8-OHdG levels are associated with adverse pregnancy outcomes. SPSS and SAS statistical software will be used for data analysis. Cox regression and competing risk analysis will be used to compute the HR and population attributable risk. This research protocol has already been approved by the Medical Ethics Committee of Beijing Obstetrics and Gynecology Hospital. Written informed consent will be obtained from all study participants prior to enrolment. The results will be published in peer-reviewed journals or disseminated through conference presentations. This study has been registered in WHO International Clinical Trial Register-Chinese Clinical Trial Registry under registrationnumber ChiCTR-ROC-16010181 (http :// www.chictr.org.cn / showproj.aspx ?proj=17328). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Refinement for fault-tolerance: An aircraft hand-off protocol
NASA Technical Reports Server (NTRS)
Marzullo, Keith; Schneider, Fred B.; Dehn, Jon
1994-01-01
Part of the Advanced Automation System (AAS) for air-traffic control is a protocol to permit flight hand-off from one air-traffic controller to another. The protocol must be fault-tolerant and, therefore, is subtle -- an ideal candidate for the application of formal methods. This paper describes a formal method for deriving fault-tolerant protocols that is based on refinement and proof outlines. The AAS hand-off protocol was actually derived using this method; that derivation is given.
Security Verification of Secure MANET Routing Protocols
2012-03-22
SECURITY VERIFICATION OF SECURE MANET ROUTING PROTOCOLS THESIS Matthew F. Steele, Captain, USAF AFIT/GCS/ ENG /12-03 DEPARTMENT OF THE AIR FORCE AIR...States AFIT/GCS/ ENG /12-03 SECURITY VERIFICATION OF SECURE MANET ROUTING PROTOCOLS THESIS Presented to the Faculty Department of Electrical and Computer...DISTRIBUTION UNLIMITED AFIT/GCS/ ENG /12-03 SECURITY VERIFICATION OF SECURE MANET ROUTING PROTOCOLS Matthew F. Steele, B.S.E.E. Captain, USAF
Microbial quality of water in dental unit waterlines.
Nikaeen, Mahnaz; Hatamzadeh, Maryam; Sabzevari, Zohre; Zareh, Omolbanin
2009-09-01
Dental unit waterlines (DUWLs) are ideal environment for development of microbial biofilms. Microbial contamination of water in DUWLs is thought to be the result of biofilm formation as it could serves as a haven for pathogens. The aim of this study was to assess microbial quality of water in dental unit waterlines of dental units located at the dental school of Isfahan University of Medical Sciences. Water samples were collected from air/water syringe and high-speed handpiece. Generally, 100-200 ml water samples were collected aseptically in sterile containers with sodium thiosulfate at the beginning of the day after a 2 minute purge. Samples were transferred to the laboratory in insulated box with cooling packs and examined for total viable heterotrophic bacteria and fungi. The heterotrophic plate count levels were significantly exceeded the American Dental Association recommendations for DUWL water quality (< 200 CFU/ml), in both air/water syringe (84%, CFU/ml: 500-20000) and high-speed handpiece (96%, CFU/ml: 710-36800) samples. However, there was no significant difference between the level of contamination in the air/water syringe and high-speed handpiece. Fungi were found in 28% and 36% of air/water syringe and high-speed handpiece samples, respectively; and filamentous fungi were the most frequently isolated fungi. DUWLs should be subjected to routine microbial monitoring and to a decontamination protocol in order to minimize the risk of exposure to potential pathogens from dental units.
Nichols, S M; Bavister, B D
2006-01-01
Cryopreservation of spermatozoa is useful for gene banking and for in vitro fertilisation (IVF). This study compared several published cryopreservation techniques to find the most efficient for rhesus macaques. Effectiveness was assessed by sperm longevity (post-thaw motility % and duration) and ability to hyperactivate in response to chemical activators (caffeine, dibutyryl cyclic AMP). Each ejaculate from three males was treated with four published cryopreservation protocols (Seier et al. 1993; Sanchez-Partida et al. 2000; Si et al. 2000; Isachenko et al. 2005). Upon thawing, each sub-sample was incubated either at 37 degrees C in 5% CO2 in air with or without activators or at approximately 22 degrees C in atmospheric air without activators for 0-24 h. Samples cryopreserved using one method showed zero motility and were not included in the 2 ;2 G-test statistical analysis. The other methods all demonstrated good immediate post-thaw motility rates (68%, 73% and 62% respectively) and underwent capacitation after exposure to activators. Sperm motility in each treatment decreased over time at both temperatures but overall, incubation at 22 degrees C preserved motility better in all three methods. In summary, cryopreservation of rhesus spermatozoa using the method published by Sanchez-Partida et al. or Seier et al. appeared best, potentially supporting gene banking as well as allowing for multiple IVF uses from the same sample.
Quantification of trace elements and speciation of iron in atmospheric particulate matter
NASA Astrophysics Data System (ADS)
Upadhyay, Nabin
Trace metal species play important roles in atmospheric redox processes and in the generation of oxidants in cloud systems. The chemical impact of these elements on atmospheric and cloud chemistry is dependent on their occurrence, solubility and speciation. First, analytical protocols have been developed to determine trace elements in particulate matter samples collected for carbonaceous analysis. The validated novel protocols were applied to the determination of trace elements in particulate samples collected in the remote marine atmosphere and urban areas in Arizona to study air pollution issues. The second part of this work investigates on solubility and speciation in environmental samples. A detailed study on the impact of the nature and strength of buffer solutions on solubility and speciation of iron lead to a robust protocol, allowing for comparative measurements in matrices representative of cloud water conditions. Application of this protocol to samples from different environments showed low iron solubility (less than 1%) in dust-impacted events and higher solubility (5%) in anthropogenically impacted urban samples. In most cases, Fe(II) was the dominant oxidation state in the soluble fraction of iron. The analytical protocol was then applied to investigate iron processing by fogs. Field observations showed that only a small fraction (1%) of iron was scavenged by fog droplets for which each of the soluble and insoluble fraction were similar. A coarse time resolution limited detailed insights into redox cycling within fog system. Overall results suggested that the major iron species in the droplets was Fe(1I) (80% of soluble iron). Finally, the occurrence and sources of emerging organic pollutants in the urban atmosphere were investigated. Synthetic musk species are ubiquitous in the urban environment (less than 5 ng m-3) and investigations at wastewater treatment plants showed that wastewater aeration basins emit a substantial amount of these species to the atmosphere.
Viegas, Carla; Faria, Tiago; Caetano, Liliana Aranha; Carolino, Elisabete; Gomes, Anita Quintal; Viegas, Susana
2017-10-01
The genus Aspergillus is one of the most prevalent regarding fungi in several highly contaminated occupational environments. The goal of the current study was to assess the prevalence of Aspergillus spp. in different settings, focusing on those where a higher load of fungal contamination is expected according to the European Agency for Safety and Health at Work. A specific protocol to ensure a more accurate assessment of the exposure to Aspergillus spp. is proposed aimed at allowing a detailed risk characterization and management. Two wastewater treatment plants, one wastewater elevation plant, four waste treatment plants, three cork industries, five slaughter houses, four feed industries, one poultry pavilion, and two swineries, all located in the outskirts of Lisbon, were assessed. In total, 125 air samples and 125 surface samples were collected and analysed by culture-based methods. Real-time polymerase chain reaction was performed to detect fungal presence in 100 samples, targeting the Aspergillus sections Circumdati, Flavi, and Fumigati. The highest prevalence of Aspergillus spp. was found in wastewater treatment plants (69.3%; 31.1%), waste treatment plants (34.8%; 73.6%), and poultry feed industry (6.3%; 26.1%), in air and surfaces, respectively. Aspergillus spp. was also prevalent in cork industry (0.9%; 23.4%), slaughter houses (1.6%; 17.7%), and swineries (7.4%; 9.5%), in air and surfaces, respectively. The Aspergillus sections more prevalent in the air and surfaces of all the assessed settings were the Nigri section (47.46%; 44.71%, respectively), followed by Fumigati (22.28%; 27.97%, respectively) and Flavi (10.78%; 11.45%, respectively) sections. Aspergillus section Fumigati was successfully amplified by qPCR in 18 sampling sites where the presence of this fungal species had not been identified by conventional methods. It should be highlighted that the occupational exposure burden is due not only to the Aspergillus load, but also to the toxigenic potential of this genus. Based on our results, a protocol relied in the application of conventional and molecular methods in parallel is herein suggested aimed at allowing a better risk characterization and management.
NASA Astrophysics Data System (ADS)
Blake, D. R.; Yang, M.; Meinardi, S.; Krauter, C.; Rowland, F. S.
2009-05-01
The San Joaquin Valley Air Pollution Control District of California issued a report identifying dairies as a main source of Volatile Organic Compounds (VOCs). A dairy study funded by the California Air Resources Board commenced shortly after the report was issued. Our University of California Irvine group teamed with California State University Fresno to determine the major sources of VOCs from various dairy operations and from a variety of dairy types. This study identified ethanol and methanol as two gases produced in major quantities throughout the dairies in the San Joaquin valley as by-products of yeast fermentation of silage. Three different types of sampling protocols were employed in order to determine the degree of enhancement of the target oxygenates in the valley air shed. Their sources, emission profiles, and emission rates were determined from whole air samples collected at various locations at the six dairies studied. An assessment of the impact of dairy emissions in the valley was achieved by using data obtained on low altitude NASA DC-8 flights through the valley, and from ground level samples collected though out the valley in a grid like design. Our data suggest that a significant amount of O3 production in the valley may come from methanol, ethanol, and acetaldehyde (a photochemical by-product ethanol oxidation). Our findings indicate that improvement to valley air quality may be obtained by focusing on instituting new silage containment practices and regulations.
Dynamics of Nafion membrane swelling in H2O/D2O mixtures as studied using FTIR technique
NASA Astrophysics Data System (ADS)
Bunkin, Nikolai F.; Kozlov, Valeriy A.; Shkirin, Alexey V.; Ninham, Barry W.; Balashov, Anatoliy A.; Gudkov, Sergey V.
2018-03-01
Experiments with Fourier transform spectrometry of Nafion, a water-swollen polymeric membrane, are described. The transmittance spectra of liquid samples and Nafion, soaked in these samples, were studied, depending on the deuterium content in water in the spectral range 1.8-2.15 μm. The experiments were carried out using two protocols: in the first protocol we studied the dynamics of Nafion swelling in H2O + D2O mixtures for the deuterium concentrations 3 < C < 104 ppm, and in the second protocol we studied the dynamics of swelling in pure heavy water (C = 106 ppm). For liquid mixtures in the concentration range 3 < C < 104 ppm, the transmittance spectra are the same, but for Nafion soaked in these fluids, the corresponding spectra are different. It is shown that, in the range of deuterium contents C = 90-500 ppm, the behavior of transmittance of the polymer membrane is non-monotonic. In experiments using the second protocol, the dynamics of diffusion replacement of residual water, which is always present in the bulk of the polymer membrane inside closed cavities (i.e., without access to atmospheric air), were studied. The experimentally estimated diffusion coefficient for this process is ≈6.10-11 cm2/s.
Chest tube management following pulmonary lobectomy: change of protocol results in fewer air leaks.
Bertholet, Joost W M; Joosten, Joris J A; Keemers-Gels, Mariël E; van den Wildenberg, Frits J H; Barendregt, Wouter B
2011-01-01
Much controversy exists regarding the management of chest tubes following pulmonary lobectomy. The objective of this study was to analyse the effect of a new chest tube management protocol on clinical features, such as postoperative air leak, drain characteristics, 30-day postoperative complications and length of hospital stay. We retrospectively analysed 133 patients who underwent pulmonary lobectomy, from January 2005 to December 2008. A new chest tube protocol was introduced on 1 January 2007 and included placement of a single chest tube and early conversion to water seal. The chest tube was removed when air leak had resolved and (non-chylous) fluid drainage was <400 ml/day. The results of patients in the old (n=68) and the new protocol (n=65) were compared. In the new protocol group the median duration of air leak and duration of chest tube drainage declined significantly. Also the length of hospital stay decreased significantly to a median of eight days. The number of reinterventions and 30-day morbidity and mortality rates did not differ significantly. Our data suggest that placement of a single chest tube and early conversion to water seal decreases the duration of air leak and chest tube drainage and length of hospital stay.
Su, Yushan; Hung, Hayley; Stern, Gary; Sverko, Ed; Lao, Randy; Barresi, Enzo; Rosenberg, Bruno; Fellin, Phil; Li, Henrik; Xiao, Hang
2011-11-01
Initiated in 1992, air monitoring of organic pollutants in the Canadian Arctic provided spatial and temporal trends in support of Canada's participation in the Stockholm Convention of Persistent Organic Pollutants. The specific analytical laboratory charged with this task was changed in 2002 while field sampling protocols remained unchanged. Three rounds of intensive comparison studies were conducted in 2004, 2005, and 2008 to assess data comparability between the two laboratories. Analysis was compared for organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in standards, blind samples of mixed standards and extracts of real air samples. Good measurement accuracy was achieved for both laboratories when standards were analyzed. Variation of measurement accuracy over time was found for some OCPs and PCBs in standards on a random and non-systematic manner. Relatively low accuracy in analyzing blind samples was likely related to the process of sample purification. Inter-laboratory measurement differences for standards (<30%) and samples (<70%) were generally less than or comparable to those reported in a previous inter-laboratory study with 21 participating laboratories. Regression analysis showed inconsistent data comparability between the two laboratories during the initial stages of the study. These inter-laboratory differences can complicate abilities to discern long-term trends of pollutants in a given sampling site. It is advisable to maintain long-term measurements with minimal changes in sample analysis.
INEEL AIR MODELING PROTOCOL ext
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. S. Staley; M. L. Abbott; P. D. Ritter
2004-12-01
Various laws stemming from the Clean Air Act of 1970 and the Clean Air Act amendments of 1990 require air emissions modeling. Modeling is used to ensure that air emissions from new projects and from modifications to existing facilities do not exceed certain standards. For radionuclides, any new airborne release must be modeled to show that downwind receptors do not receive exposures exceeding the dose limits and to determine the requirements for emissions monitoring. For criteria and toxic pollutants, emissions usually must first exceed threshold values before modeling of downwind concentrations is required. This document was prepared to provide guidancemore » for performing environmental compliance-driven air modeling of emissions from Idaho National Engineering and Environmental Laboratory facilities. This document assumes that the user has experience in air modeling and dose and risk assessment. It is not intended to be a "cookbook," nor should all recommendations herein be construed as requirements. However, there are certain procedures that are required by law, and these are pointed out. It is also important to understand that air emissions modeling is a constantly evolving process. This document should, therefore, be reviewed periodically and revised as needed. The document is divided into two parts. Part A is the protocol for radiological assessments, and Part B is for nonradiological assessments. This document is an update of and supersedes document INEEL/INT-98-00236, Rev. 0, INEEL Air Modeling Protocol. This updated document incorporates changes in some of the rules, procedures, and air modeling codes that have occurred since the protocol was first published in 1998.« less
Wetherbee, Gregory A.; Shaw, Michael J.; Latysh, Natalie E.; Lehmann, Christopher M.B.; Rothert, Jane E.
2010-01-01
Precipitation chemistry and depth measurements obtained by the Canadian Air and Precipitation Monitoring Network (CAPMoN) and the US National Atmospheric Deposition Program/National Trends Network (NADP/NTN) were compared for the 10-year period 1995–2004. Colocated sets of CAPMoN and NADP instrumentation, consisting of precipitation collectors and rain gages, were operated simultaneously per standard protocols for each network at Sutton, Ontario and Frelighsburg, Ontario, Canada and at State College, PA, USA. CAPMoN samples were collected daily, and NADP samples were collected weekly, and samples were analyzed exclusively by each network’s laboratory for pH, H + , Ca2+ , Mg2+ , Na + , K + , NH+4 , Cl − , NO−3 , and SO2−4 . Weekly and annual precipitation-weighted mean concentrations for each network were compared. This study is a follow-up to an earlier internetwork comparison for the period 1986–1993, published by Alain Sirois, Robert Vet, and Dennis Lamb in 2000. Median weekly internetwork differences for 1995–2004 data were the same to slightly lower than for data for the previous study period (1986–1993) for all analytes except NO−3 , SO2−4 , and sample depth. A 1994 NADP sampling protocol change and a 1998 change in the types of filters used to process NADP samples reversed the previously identified negative bias in NADP data for hydrogen-ion and sodium concentrations. Statistically significant biases (α = 0.10) for sodium and hydrogen-ion concentrations observed in the 1986–1993 data were not significant for 1995–2004. Weekly CAPMoN measurements generally are higher than weekly NADP measurements due to differences in sample filtration and field instrumentation, not sample evaporation, contamination, or analytical laboratory differences.
Legionella in Puerto Rico cooling towers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Negron-Alviro, A.; Perez-Suarez, I.; Hazen, T.C.
1988-12-31
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, Puerto Rico were assayed for various species and serogroups of Legionella spp. using direct immunofluorescence. Several water quality parameters were also measured with each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila (1-6), L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species, reaching 10{sup 5} cells/ml, within the range that is considered potentially pathogenic tomore » humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (AODC), were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems, and without continuous biocide treatment may reach densities that present a health risk.« less
Viegas, Carla; Faria, Tiago; dos Santos, Mateus; Carolino, Elisabete; Sabino, Raquel; Quintal Gomes, Anita; Viegas, Susana
2016-01-01
In slaughterhouses, the biological risk is present not only from the direct or indirect contact with animal matter, but also from the exposure to bioaerosols. Fungal contamination was already reported from the floors and walls of slaughterhouses. This study intends to assess fungal contamination by cultural and molecular methods in poultry, swine/bovine and large animal slaughterhouses. Air samples were collected through an impaction method, while surface samples were collected by the swabbing method and subjected to further macro- and micro-scopic observations. In addition, we collected air samples using the impinger method in order to perform real-time quantitative PCR (qPCR) amplification of genes from specific fungal species, namely A. flavus, A. fumigatus and A. ochraceus complexes. Poultry and swine/bovine slaughterhouses presented each two sampling sites that surpass the guideline of 150 CFU/m3. Scopulariopsis candida was the most frequently isolated (59.5%) in poultry slaughterhouse air; Cladosporium sp. (45.7%) in the swine/bovine slaughterhouse; and Penicillium sp. (80.8%) in the large animal slaughterhouse. Molecular tools successfully amplified DNA from the A. fumigatus complex in six sampling sites where the presence of this fungal species was not identified by conventional methods. This study besides suggesting the indicators that are representative of harmful fungal contamination, also indicates a strategy as a protocol to ensure a proper characterization of fungal occupational exposure. PMID:27005642
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steger, J.L.; Bursey, J.T.; Merrill, R.G.
1999-03-01
This report presents the results of laboratory studies to develop and evaluate a method for the sampling and analysis of phosgene from stationary sources of air emissions using diethylamine (DEA) in toluene as the collection media. The method extracts stack gas from emission sources and stabilizes the reactive gas for subsequent analysis. DEA was evaluated both in a benchtop study and in a laboratory train spiking study. This report includes results for both the benchtop study and the train spiking study. Benchtop studies to evaluate the suitability of DEA for collecting and analyzing phosgene investigated five variables: storage time, DEAmore » concentration, moisture/pH, phosgene concentration, and sample storage temperature. Prototype sampling train studies were performed to determine if the benchtop chemical studies were transferable to a Modified Method 5 sampling train collecting phosgene in the presence of clean air mixed with typical stack gas components. Four conditions, which varied the moisture and phosgene spike were evaluated in triplicate. In addition to research results, the report includes a detailed draft method for sampling and analysis of phosgene from stationary source emissions.« less
Comparison of culture media for the recovery of airborne yeast in wineries.
Ocón, E; Garijo, P; Santamaría, P; López, R; Olarte, C; Gutiérrez, A R; Sanz, S
2013-09-01
The direct air sampling impaction method on agar was evaluated using aerobiocollectors for the recovery of yeasts present in the winery air. Three culture media with different composition and specificity were studied. In addition, a resuscitation phase was included before the culture in the specificity medium [in the case of the Dekkera-Brettanomyces Differential Medium (DBDM) medium]. Sampling was conducted at different times of the year and in different parts of the wineries, which were different in age and design. Both the Chloramphenicol Glucose Agar (CGA) and Agar Lysine AL media recovered yeasts from the air without any prior resuscitation phase. CGA was able to recover a higher number of colony-forming units of yeasts than the other media. Consequently, to estimate the number of yeasts present in winery air, the best choice of medium would be CGA. The AL medium permitted the growth of the greatest range of genera and species. If the aim is to study the diversity of yeasts present in the air, the most suitable medium is AL. Neither CGA nor AL proved suitable for recovering yeasts of the Brettanomyces genus. The DBDM medium was the only one which provided sufficient specificity for their recovery and identification from the air, although their special characteristics made a prior protocol of resuscitation necessary. © 2013 The Society for Applied Microbiology.
A proactive approach for managing indoor air quality
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greene, R.E.; Casey, J.M.; Williams, P.L.
1997-11-01
Ventilation and maintenance, followed by psychosocial issues, are the factors most often implicated in indoor air quality (IAQ) investigations. The absence of accepted exposure standards and the presence of a wide variety of building designs, ages, ventilation systems, and usages often make IAQ complaint investigations ineffective. Thus, the best approach to achieving IAQ is to prevent problems from occurring. This paper presents the framework for a proactive approach to managing the causes most often implicated in IAQ investigations. It is the aim of this proactive protocol to provide a cost-effective guide for preventing IAQ problems in nonindustrial settings and inmore » buildings for which there are no current IAQ complaints. The proposed protocol focuses on heating, ventilation, and air-conditioning (HVAC) system maintenance and operation; psychosocial factors; and the handling and investigation of complaints. An IAQ manager is designated to implement and manage the protocol. The HVAC system portion of the protocol focuses on proper maintenance of the components often identified as sources of problems in IAQ studies, documentation of the maintenance procedures, and training of individuals responsible for building maintenance. The protocol addresses the psychosocial factors with an environmental survey that rates the occupants` perceptions of the indoor air to identify potential IAQ problems. The psychosocial portion of the protocol also incorporates occupant education and awareness. Finally, a three-step initial investigation procedure for addressing IAQ problems is presented.« less
Air toxics evaluation of ABB Combustion Engineering Low-Emission Boiler Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wesnor, J.D.
1993-10-26
The specific goals of the program are to identify air toxic compounds that might be emmitted from the new boiler with its various Air Pollution Control device for APCD alternatives in levels of regulatory concern. For the compounds thought to be of concern, potential air toxic control methodologies will be suggested and a Test Protocol will be written to be used in the Proof of Concept and full scale tests. The following task was defined: Define Replations and Standards; Identify Air Toxic Pollutants of Interest to Interest to Utility Boilers; Assesment of Air Toxic By-Products; State of the Art Assessmentmore » of Toxic By-Product Control Technologies; and Test Protocol Definition.« less
Viegas, Carla; Faria, Tiago; Monteiro, Ana; Caetano, Liliana Aranha; Carolino, Elisabete; Quintal Gomes, Anita; Viegas, Susana
2017-12-27
Swine production has been associated with health risks and workers' symptoms. In Portugal, as in other countries, large-scale swine production involves several activities in the swine environment that require direct intervention, increasing workers' exposure to organic dust. This study describes an updated protocol for the assessment of occupational exposure to organic dust, to unveil an accurate scenario regarding occupational and environmental risks for workers' health. The particle size distribution was characterized regarding mass concentration in five different size ranges (PM0.5, PM1, PM2.5, PM5, PM10). Bioburden was assessed, by both active and passive sampling methods, in air, on surfaces, floor covering and feed samples, and analyzed through culture based-methods and qPCR. Smaller size range particles exhibited the highest counts, with indoor particles showing higher particle counts and mass concentration than outdoor particles. The limit values suggested for total bacteria load were surpassed in 35.7% (10 out of 28) of samples and for fungi in 65.5% (19 out of 29) of samples. Among Aspergillus genera, section Circumdati was the most prevalent (55%) on malt extract agar (MEA) and Versicolores the most identified (50%) on dichloran glycerol (DG18). The results document a wide characterization of occupational exposure to organic dust on swine farms, being useful for policies and stakeholders to act to improve workers' safety. The methods of sampling and analysis employed were the most suitable considering the purpose of the study and should be adopted as a protocol to be followed in future exposure assessments in this occupational environment.
Speech outcome in unilateral complete cleft lip and palate patients: a descriptive study.
Rullo, R; Di Maggio, D; Addabbo, F; Rullo, F; Festa, V M; Perillo, L
2014-09-01
In this study, resonance and articulation disorders were examined in a group of patients surgically treated for cleft lip and palate, considering family social background, and children's ability of self monitoring their speech output while speaking. Fifty children (32 males and 18 females) mean age 6.5 ± 1.6 years, affected by non-syndromic complete unilateral cleft of the lip and palate underwent the same surgical protocol. The speech level was evaluated using the Accordi's speech assessment protocol that focuses on intelligibility, nasality, nasal air escape, pharyngeal friction, and glottal stop. Pearson product-moment correlation analysis was used to detect significant associations between analysed parameters. A total of 16% (8 children) of the sample had severe to moderate degree of nasality and nasal air escape, presence of pharyngeal friction and glottal stop, which obviously compromise speech intelligibility. Ten children (10%) showed a barely acceptable phonological outcome: nasality and nasal air escape were mild to moderate, but the intelligibility remained poor. Thirty-two children (64%) had normal speech. Statistical analysis revealed a significant correlation between the severity of nasal resonance and nasal air escape (p ≤ 0.05). No statistical significant correlation was found between the final intelligibility and the patient social background, neither between the final intelligibility nor the age of the patients. The differences in speech outcome could be explained with a specific, subjective, and inborn ability, different for each child, in self-monitoring their speech output.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 75 [EPA-HQ-OAR-2009-0837; FRL-9280-9] RIN 2060-AQ06 Protocol Gas Verification Program and Minimum Competency Requirements for Air Emission Testing Correction In rule document 2011-6216 appearing on pages 17288-17325 in the issue of Monday, March 28, 2011...
Minet, L; Gehr, R; Hatzopoulou, M
2017-11-01
The development of reliable measures of exposure to traffic-related air pollution is crucial for the evaluation of the health effects of transportation. Land-use regression (LUR) techniques have been widely used for the development of exposure surfaces, however these surfaces are often highly sensitive to the data collected. With the rise of inexpensive air pollution sensors paired with GPS devices, we witness the emergence of mobile data collection protocols. For the same urban area, can we achieve a 'universal' model irrespective of the number of locations and sampling visits? Can we trade the temporal representation of fixed-point sampling for a larger spatial extent afforded by mobile monitoring? This study highlights the challenges of short-term mobile sampling campaigns in terms of the resulting exposure surfaces. A mobile monitoring campaign was conducted in 2015 in Montreal; nitrogen dioxide (NO 2 ) levels at 1395 road segments were measured under repeated visits. We developed LUR models based on sub-segments, categorized in terms of the number of visits per road segment. We observe that LUR models were highly sensitive to the number of road segments and to the number of visits per road segment. The associated exposure surfaces were also highly dissimilar. Copyright © 2017 Elsevier Ltd. All rights reserved.
Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marberry, Hugh; Moore, Winston
2013-07-01
Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate inputmore » errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)« less
de la Gala Morales, María; Holgado, Fernando Rueda; Marín, Ma Rosario Palomo; Blázquez, Lorenzo Calvo; Gil, Eduardo Pinilla
2015-04-01
A new methodology involving a simple and fast pretreatment of the samples by microwave-assisted extraction and concentration by N2 stream, followed by HPLC with fluorescence detection, was used for determining the concentration of benzo(a)pyrene (BaP) in atmospheric particulate matter (PM10 fraction). Obtained LOD, 1.0 × 10(-3) ng/m(3), was adequate for the analysis of benzo(a)pyrene in the samples, and BaP recovery from PAH in Fine Dust (PM10-like) certified reference material was nearly quantitative (86%). The validated procedure was applied for analyzing 115 PM10 samples collected at different sampling locations in the low-polluted area of Extremadura (Southwest Spain) during a monitoring campaign carried out in 2011-2012. BaP spatial variations and seasonal variability were investigated as well as the influence of meteorological conditions and different air pollutants concentrations. A normalized protocol for health risk assessment was applied to estimate lifetime cancer risk due to BaP inhalation in the sampling areas, finding that around eight inhabitants per million people may develop lung cancer due to the exposition to BaP in atmospheric particulates emitted by the investigated sources.
Preparation of isolated biomolecules for SFM observations: T4 bacteriophage as a test sample.
Droz, E; Taborelli, M; Wells, T N; Descouts, P
1993-01-01
The T4 bacteriophage has been used to investigate protocols for the preparation of samples for scanning force microscopy in air, in order to obtaining reproducible images. The resolution of images and the distribution of bacteriophages on the substrate depends on the buffer type, its concentration, the surface treatment of substrate, and the method of deposition. The best imaging conditions for the phages require dilution in a volatile buffer at low ionic strength and adsorption onto hydrophilic surfaces. When imaging with the scanning force microscopy the quality of the images is influenced by the vertical and lateral forces applied on the sample and by the tip geometry. Images FIGURE 1 FIGURE 2 FIGURE 4 FIGURE 5 FIGURE 6 PMID:8241398
Legionella spp. in Puerto Rico cooling towers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Negron-Alvira, A.; Perez-Suarez, I.; Hazen, T.C.
1988-10-01
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10{sup 5} cells per ml, which is within themore » range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.« less
Thomas, Stephanie; Palmer, Rish; Phillipo, Edward; Chipungu, Geoffrey
2016-05-31
All surgical procedures have the potential for infection and some of the main sources are contamination from airborne particles, theatre personnel and the theatre environment. There is strong evidence that the use of ultra-clean air flow systems in orthopedic operating theatres reduces the incidence of deep sepsis after surgery. In the developing world however, this is often an unrealistic solution. The aim of this study was to establish baseline levels of contamination in a working orthopedic theatre, at the Queen Elizabeth Central Hospital, Blantyre, Malawi. To feedback results to the theatre team, promote infection prevention discussion and work with the team to implement workable and realistic goals to improve the intra-operative environment. Samples were collected from theatre equipment available at the time of surgery, from theatre water and theatre air using passive air sampling techniques. Samples were immediately transferred to the Central Microbiology Laboratory for culture on basic culture media. Bacterial contamination of theatre equipment, intra-operative theatre air and water was detected. Results were discussed with the theatre and infection prevention team who were receptive to feedback with regards to infection prevention strategies and keen to develop simple measures which could be put in place to change practice. In this setting, we suggest that implementing workable and realistic goals such as, establishing baseline rates of bacterial contamination and introduction of strict protocols for asepsis and theatre etiquette, may reduce bacterial contamination rates and subsequent intra-operative infection in the absence of expensive engineering solutions.
Faria, Tiago; Monteiro, Ana; Carolino, Elisabete; Quintal Gomes, Anita
2017-01-01
Swine production has been associated with health risks and workers’ symptoms. In Portugal, as in other countries, large-scale swine production involves several activities in the swine environment that require direct intervention, increasing workers’ exposure to organic dust. This study describes an updated protocol for the assessment of occupational exposure to organic dust, to unveil an accurate scenario regarding occupational and environmental risks for workers’ health. The particle size distribution was characterized regarding mass concentration in five different size ranges (PM0.5, PM1, PM2.5, PM5, PM10). Bioburden was assessed, by both active and passive sampling methods, in air, on surfaces, floor covering and feed samples, and analyzed through culture based-methods and qPCR. Smaller size range particles exhibited the highest counts, with indoor particles showing higher particle counts and mass concentration than outdoor particles. The limit values suggested for total bacteria load were surpassed in 35.7% (10 out of 28) of samples and for fungi in 65.5% (19 out of 29) of samples. Among Aspergillus genera, section Circumdati was the most prevalent (55%) on malt extract agar (MEA) and Versicolores the most identified (50%) on dichloran glycerol (DG18). The results document a wide characterization of occupational exposure to organic dust on swine farms, being useful for policies and stakeholders to act to improve workers’ safety. The methods of sampling and analysis employed were the most suitable considering the purpose of the study and should be adopted as a protocol to be followed in future exposure assessments in this occupational environment. PMID:29280976
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-12-31
Describes a study undertaken to assess the indoor air quality in the Clos St-Andre, a 78-unit residential complex in downtown Montreal, through the implementation of a monitoring protocol in three of the building`s suites; and to examine the relationships between mechanical ventilation, material emissions, occupant lifestyle, and indoor air pollutant concentrations. The monitoring protocol consisted of tracer gas, air exchange testing, material emission testing, airtightness testing, and the monitoring of air temperature, relative humidity, carbon dioxide, carbon monoxide, formaldehyde, and total volatile organic carbon in the suites. Trends in pollutant concentrations over time in the post-construction period are noted.
Esplugues, Ana; Fernández-Patier, Rosalía; Aguilera, Inma; Iñíguez, Carmen; García Dos Santos, Saúl; Aguirre Alfaro, Amelia; Lacasaña, Marina; Estarlich, Marisa; Grimalt, Joan O; Fernández, Marieta; Rebagliato, Marisa; Sala, María; Tardón, Adonina; Torrent, Maties; Martínez, María Dolores; Ribas-Fitó, Núria; Sunyer, Jordi; Ballester, Ferran
2007-01-01
The INMA (INfancia y Medio Ambiente [Spanish for Environment and Childhood]) project is a cooperative research network. This project aims to study the effects of environment and diet on fetal and early childhood development. This article aims to present the air pollutant exposure protocol during pregnancy and fetal and early childhood development of the INMA project. The information to assess air pollutant exposure during pregnancy is based on outdoor measurement of air pollutants (nitrogen dioxide [NO2], volatile organic compounds [VOC], ozone, particulate matter [PM10, PM2,5 ] and of their composition [polycyclic aromatic hydrocarbons]); measurement of indoor and personal exposure (VOC and NO2); urinary measurement of a biological marker of hydrocarbon exposure (1-hydroxypyrene); and data gathered by questionnaires and geographic information systems. These data allow individual air pollutant exposure indexes to be developed, which can then be used to analyze the possible effects of exposure on fetal development and child health. This protocol and the type of study allow an approximation to individual air pollutant exposure to be obtained. Finally, the large number of participants (N = 4,000), as well as their geographic and social diversity, increases the study's potential.
ENVIRONMENTAL TECHNOLOGY VERIFICATION TEST PROTOCOL, GENERAL VENTILATION FILTERS
The Environmental Technology Verification Test Protocol, General Ventilation Filters provides guidance for verification tests.
Reference is made in the protocol to the ASHRAE 52.2P "Method of Testing General Ventilation Air-cleaning Devices for Removal Efficiency by P...
Emulation of Industrial Control Field Device Protocols
2013-03-01
platforms such as the Arduino ( based on the Atmel AVR architecture) or popular PIC architecture based devices, which are programmed for specific functions...UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base , Ohio DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION...confidence intervals for the mean. Based on these results, extensive knowledge of the specific implementations of the protocols or timing profiles of the
Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA.
Lemons, Angela R; Lindsley, William G; Green, Brett J
2018-05-02
Traditional methods of identifying fungal exposures in occupational environments, such as culture and microscopy-based approaches, have several limitations that have resulted in the exclusion of many species. Advances in the field over the last two decades have led occupational health researchers to turn to molecular-based approaches for identifying fungal hazards. These methods have resulted in the detection of many species within indoor and occupational environments that have not been detected using traditional methods. This protocol details an approach for determining fungal diversity within air samples through genomic DNA extraction, amplification, sequencing, and taxonomic identification of fungal internal transcribed spacer (ITS) regions. ITS sequencing results in the detection of many fungal species that are either not detected or difficult to identify to species level using culture or microscopy. While these methods do not provide quantitative measures of fungal burden, they offer a new approach to hazard identification and can be used to determine overall species richness and diversity within an occupational environment.
Cristale, Joyce; Katsoyiannis, Athanasios; Sweetman, Andrew J; Jones, Kevin C; Lacorte, Silvia
2013-08-01
This study presents the occurrence and risk of PBDEs, new brominated and organophosphorus flame retardants along a river affected by urban and industrial pressures (River Aire, UK). Tris(2-choroethyl) phosphate (TCEP), tris(2-chloro-1-methylethyl) phosphate (TCPP), tris[2-chloro-1-(chloromethyl)ethyl] phosphate (TDCP) and triphenyl phosphate (TPhP) were detected in all samples, with TCPP present at the highest concentrations, ranging from 113 to 26,050 ng L⁻¹. BDE-209 was detected in most of the sampled sites, ranging from 17 to 295 ng L⁻¹, while hexabromobenzene (HBB) and pentabromoethyl benzene (PBEB) were seldom detected. A risk quotients based on predicted no effect concentrations (PNEC) and flame retardants water concentration proved significant risk for adverse effects for algae, Daphnia and fish in sites close to industrial and urban sewage discharges. This study provides a protocol for the risk estimation of priority and new generation flame retardants based on river concentrations and toxicological values. Copyright © 2013 Elsevier Ltd. All rights reserved.
Under EPA's Environmental Technology Verification Program, Research Triangle Institute (RTI) will operate the Air Pollution Control Technology Center to verify the filtration efficiency and bioaerosol inactivation efficiency of heating, ventilation and air conditioning air cleane...
NASA Astrophysics Data System (ADS)
Laurent, B.; Losno, R.; Chevaillier, S.; Vincent, J.; Roullet, P.; Bon Nguyen, E.; Ouboulmane, N.; Triquet, S.; Fornier, M.; Raimbault, P.; Bergametti, G.
2015-07-01
Deposition is one of the key terms of the mineral dust cycle. However, dust deposition remains poorly constrained in transport models simulating the atmospheric dust cycle. This is mainly due to the limited number of relevant deposition measurements. This paper aims to present an automatic collector (CARAGA), specially developed to sample the total (dry and wet) atmospheric deposition of insoluble dust in remote areas. The autonomy of the CARAGA can range from 25 days to almost 1 year depending on the programmed sampling frequency (from 1 day to 2 weeks respectively). This collector is used to sample atmospheric deposition of Saharan dust on the Frioul islands in the Gulf of Lions in the Western Mediterranean. To quantify the mineral dust mass in deposition samples, a weighing and ignition protocol is applied. Almost 2 years of continuous deposition measurements performed on a weekly sampling basis on Frioul Island are presented and discussed with air mass trajectories and satellite observations of dust. Insoluble mineral deposition measured on Frioul Island was 2.45 g m-2 for February to December 2011 and 3.16 g m-2 for January to October 2012. Nine major mineral deposition events, measured during periods with significant MODIS aerosol optical depths, were associated with air masses coming from the southern Mediterranean Basin and North Africa.
VALIDATION OF STANDARD ANALYTICAL PROTOCOL FOR ...
There is a growing concern with the potential for terrorist use of chemical weapons to cause civilian harm. In the event of an actual or suspected outdoor release of chemically hazardous material in a large area, the extent of contamination must be determined. This requires a system with the ability to prepare and quickly analyze a large number of contaminated samples for the traditional chemical agents, as well as numerous toxic industrial chemicals. Liquid samples (both aqueous and organic), solid samples (e.g., soil), vapor samples (e.g., air) and mixed state samples, all ranging from household items to deceased animals, may require some level of analyses. To meet this challenge, the U.S. Environmental Protection Agency (U.S. EPA) National Homeland Security Research Center, in collaboration with experts from across U.S. EPA and other Federal Agencies, initiated an effort to identify analytical methods for the chemical and biological agents that could be used to respond to a terrorist attack or a homeland security incident. U.S. EPA began development of standard analytical protocols (SAPs) for laboratory identification and measurement of target agents in case of a contamination threat. These methods will be used to help assist in the identification of existing contamination, the effectiveness of decontamination, as well as clearance for the affected population to reoccupy previously contaminated areas. One of the first SAPs developed was for the determin
NASA Astrophysics Data System (ADS)
Barletta, B.; Nissenson, P.; Meinardi, S.; Dabdub, D.; Sherwood Rowland, F.; Vancuren, R. A.; Pederson, J.; Diskin, G. S.; Blake, D. R.
2011-03-01
This work presents results from the NASA Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) study. Whole air samples were obtained on board research flights that flew over California during June 2008 and analyzed for selected volatile organic compounds, including several halogenated species. Samples collected over the South Coast Air Basin of California (SoCAB), which includes much of Los Angeles (LA) County, were compared with samples from inflow air masses over the Pacific Ocean. The levels of many halocarbon species were enhanced significantly over the SoCAB, including compounds regulated by the Montreal Protocol and subsequent amendments. Emissions estimates of HFC-152a (1,1-difluoroethane, CH3CHF2; 0.82 ± 0.11 Gg) and HFC-134a (1,1,1,2-tetrafluoroethane, CH2FCF3; 1.16 ± 0.22 Gg) in LA County for 2008 were obtained using the observed HFC:carbon monoxide (CO) enhancement ratio. Emission rates also were calculated for the SoCAB (1.60 ± 0.22 Gg yr-1 for HFC-152a and 2.12 ± 0.28 Gg yr-1 for HFC-134a) and then extrapolated to the United States (32 ± 4 Gg yr-1 for HFC-152a and 43 ± 6 Gg yr-1 for HFC-134a) using population data. In addition, emission rates of the two HFCs in LA County and SoCAB were calculated by a second method that utilizes air quality modeling. Emissions estimates obtained using both methods differ by less than 25% for the LA County and less than 45% for the SoCAB.
Proteomics of exhaled breath: methodological nuances and pitfalls.
Kurova, Viktoria S; Anaev, Eldar C; Kononikhin, Alexey S; Fedorchenko, Kristina Yu; Popov, Igor A; Kalupov, Timothey L; Bratanov, Dmitriy O; Nikolaev, Eugenie N; Varfolomeev, Sergey D
2009-01-01
The analysis of exhaled breath condensate (EBC) can be an alternative to traditional endoscopic sampling of lower respiratory tract secretions. This is a simple non-invasive method of diagnosing respiratory diseases, in particular, respiratory inflammatory processes. Samples were collected with a special device-condenser (ECoScreen, VIASYS Healthcare, Germany), then treated with trypsin according to the proteomics protocol for standard protein mixtures and analyzed by nanoflow high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) with a 7-Tesla Finnigan LTQ-FT mass spectrometer (Thermo Electron, Germany). Mascot software (Matrixscience) was used for screening the database NCBInr for proteins corresponding to the peptide maps that were obtained. EBCs from 17 young healthy non-smoking donors were collected. Different methods for concentrating protein were compared in order to optimize EBC preparations for proteomic analysis. The procedure that was chosen allowed identification of proteins exhaled by healthy people. The major proteins in the condensates were cytoskeletal keratins. Another 12 proteins were identified in EBC from healthy non-smokers. Some keratins were found in the ambient air and may be considered exogenous components of exhaled air. Knowledge of the normal proteome of exhaled breath allows one to look for biomarkers of different disease states in EBC. Proteins in ambient air can be identified in the respiratory tract and should be excluded from the analysis of the proteome of EBC. The results obtained allowed us to choose the most effective procedure of sample preparation when working with samples containing very low protein concentrations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drzymala, R. E., E-mail: drzymala@wustl.edu; Alvarez, P. E.; Bednarz, G.
2015-11-15
Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods:more » Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG-21 + ABS dose-rate were 0.999 ± 0.009 (TG-21), 0.991 ± 0.013 (TG-51), 1.000 ± 0.009 (IAEA), and 1.009 ± 0.012 (in-air). There were no statistically significant differences (i.e., p > 0.05) between the two ionization chambers for the TG-21 protocol applied to all dosimetry phantoms. The mean results using the TG-51 protocol were notably lower than those for the other dosimetry protocols, with a standard deviation 2–3 times larger. The in-air protocol was not statistically different from TG-21 for the A16 chamber in the liquid water or ABS phantoms (p = 0.300 and p = 0.135) but was statistically different from TG-21 for the PTW chamber in all phantoms (p = 0.006 for Solid Water, 0.014 for liquid water, and 0.020 for ABS). Results of IAEA formalism were statistically different from TG-21 results only for the combination of the A16 chamber with the liquid water phantom (p = 0.017). In the latter case, dose-rates measured with the two protocols differed by only 0.4%. For other phantom-ionization-chamber combinations, the new IAEA formalism was not statistically different from TG-21. Conclusions: Although further investigation is needed to validate the new protocols for other ionization chambers, these results can serve as a reference to quantitatively compare different calibration protocols and ionization chambers if a particular method is chosen by a professional society to serve as a standardized calibration protocol.« less
NASA Technical Reports Server (NTRS)
Allton, J. H.; Zeigler, R. A.; Calaway, M. J.
2016-01-01
The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.
Witschger, O; Grinshpun, S A; Fauvel, S; Basso, G
2004-06-01
While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the dust source, faces the source. Thus, the first objective of this study was to design and test a new, low cost experimental protocol for measuring the sampling efficiency of personal inhalable aerosol samplers in the vicinity of the aerosol source when the samplers operate in very slowly moving air. In this system, an aerosol generator, which is located in the centre of a room-sized non-ventilated chamber, continuously rotates and omnidirectionally disperses test particles of a specific size. The test and reference samplers are equally distributed around the source at the same distance from the centre and operate in parallel (in most of our experiments, the total number of simultaneously operating samplers was 15). Radial aerosol transport is driven by turbulent diffusion and some natural convection. For each specific particle size and the sampler, the aerosol mass concentration is measured by weighing the collection filter. The second objective was to utilize the new protocol to evaluate three widely used aerosol samplers: the IOM Personal Inhalable Sampler, the Button Personal Inhalable Aerosol Sampler and the 25 mm Millipore filter holder (closed-face C25 cassette). The sampling efficiencies of each instrument were measured with six particle fractions, ranging from 6.9 to 76.9 micro m in their mass median aerodynamic diameter. The Button Sampler efficiency data demonstrated a good agreement with the standard inhalable convention and especially with the low air movement inhalabilty curve. The 25 mm filter holder was found to considerably under-sample the particles larger than 10 micro m; its efficiency did not exceed 7% for particles of 40-100 micro m. The IOM Sampler facing the source was found to over-sample compared with the data obtained previously with a slowly rotating, freely suspended sampler in a low air movement environment. It was also found that the particle wall deposition in the IOM metallic cartridge was rather significant and particle size-dependent. For each sampler (IOM, Button and C25) the precision was characterized through the relative standard deviation (RSD) of the aerosol concentration obtained with identical samplers in a specific experiment. The average RSD was 14% for the IOM Sampler, 11% for the Button Sampler and 35% for the 25 mm filter cassette. A separate set of experiments, performed with the Simplified Torso showed that in very slowly moving air a personal sampler can be adequately evaluated even when it is not attached to a body but freely suspended (confirming the data reported previously).
Knight, G M; McIntyre, J M; Mulyani
2006-03-01
Diamine silver fluoride (Ag(NH3)2F), referred to as AgF, has been shown to reduce the incidence of caries in primary dentitions. The clinical application of this material has been limited by staining associated with both teeth and restorative materials. The application of potassium iodide (KI) after AgF eliminates stain formation. There is a lack of information as to how the addition of AgF followed by KI may affect the bond strength to dentine. The purpose of this study was to compare the bond strengths of auto cure glass ionomer cement to dentine surfaces that had been treated with AgF and KI and without treatment. Ten recently extracted human third molars were embedded into methyl methacrylate resin and sliced to form a square block of exposed dentine surfaces. Each of the four surfaces were treated by one of the following procedures: (a) etching with 37 per cent phosphoric acid; (b) applying GC dentine conditioner; (c) etching, followed by application of AgF/KI then washing off the precipitate and air drying; and (d) etching, applying AgF/KI and air drying the reaction products on the surface. Fuji VII auto cure glass ionomer cement was bonded onto each sample and fracture tested. The dentine samples treated with AgF/KI followed by washing away the precipitate and air drying had bond strengths (2.83 MPa) not significantly different from samples that had been conditioned (2.40 MPa). Samples where the AgF/KI precipitate had been air dried onto the dentine surface had significantly lower bond strengths (1.49 MPa) than the washed samples. Samples that were etched had significantly lower bond strengths (1.91MPa) than the conditioned samples. This study found that the application of AgF/KI to etched dentine samples followed by washing off the precipitate, created bond strengths that were not significantly different to conditioned samples. Leaving the AgF/KI precipitate on the dentine surface significantly reduced the bond strength of auto cured glass ionomer cement to dentine. Washing away the reaction products and air drying is recommended as the clinical protocol for using AgF and KI on dentine surfaces prior to application of an auto cure glass ionomer cement.
Test Protocol for Room-to-Room Distribution of Outside Air by Residential Ventilation Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barley, C. D.; Anderson, R.; Hendron, B.
2007-12-01
This test and analysis protocol has been developed as a practical approach for measuring outside air distribution in homes. It has been used successfully in field tests and has led to significant insights on ventilation design issues. Performance advantages of more sophisticated ventilation systems over simpler, less-costly designs have been verified, and specific problems, such as airflow short-circuiting, have been identified.
Establishing a method to measure bone structure using spectral CT
NASA Astrophysics Data System (ADS)
Ramyar, M.; Leary, C.; Raja, A.; Butler, A. P. H.; Woodfield, T. B. F.; Anderson, N. G.
2017-03-01
Combining bone structure and density measurement in 3D is required to assess site-specific fracture risk. Spectral molecular imaging can measure bone structure in relation to bone density by measuring macro and microstructure of bone in 3D. This study aimed to optimize spectral CT methodology to measure bone structure in excised bone samples. MARS CT with CdTe Medipix3RX detector was used in multiple energy bins to calibrate bone structure measurements. To calibrate thickness measurement, eight different thicknesses of Aluminium (Al) sheets were scanned one in air and the other around a falcon tube and then analysed. To test if trabecular thickness measurements differed depending on scan plane, a bone sample from sheep proximal tibia was scanned in two orthogonal directions. To assess the effect of air on thickness measurement, two parts of the same human femoral head were scanned in two conditions (in the air and in PBS). The results showed that the MARS scanner (with 90μm voxel size) is able to accurately measure the Al (in air) thicknesses over 200μm but it underestimates the thicknesses below 200μm because of partial volume effect in Al-air interface. The Al thickness measured in the highest energy bin is overestimated at Al-falcon tube interface. Bone scanning in two orthogonal directions gives the same trabecular thickness and air in the bone structure reduced measurement accuracy. We have established a bone structure assessment protocol on MARS scanner. The next step is to combine this with bone densitometry to assess bone strength.
Balakrishnan, Kalpana; Sambandam, Sankar; Ramaswamy, Padmavathi; Ghosh, Santu; Venkatesan, Vettriselvi; Thangavel, Gurusamy; Mukhopadhyay, Krishnendu; Johnson, Priscilla; Paul, Solomon; Puttaswamy, Naveen; Dhaliwal, Rupinder S; Shukla, D K
2015-01-01
Introduction In rapidly developing countries such as India, the ubiquity of air pollution sources in urban and rural communities often results in ambient and household exposures significantly in excess of health-based air quality guidelines. Few efforts, however, have been directed at establishing quantitative exposure–response relationships in such settings. We describe study protocols for The Tamil Nadu Air Pollution and Health Effects (TAPHE) study, which aims to examine the association between fine particulate matter (PM2.5) exposures and select maternal, child and adult health outcomes in integrated rural–urban cohorts. Methods and analyses The TAPHE study is organised into five component studies with participants drawn from a pregnant mother–child cohort and an adult cohort (n=1200 participants in each cohort). Exposures are assessed through serial measurements of 24–48 h PM2.5 area concentrations in household microenvironments together with ambient measurements and time-activity recalls, allowing exposure reconstructions. Generalised additive models will be developed to examine the association between PM2.5 exposures, maternal (birth weight), child (acute respiratory infections) and adult (chronic respiratory symptoms and lung function) health outcomes while adjusting for multiple covariates. In addition, exposure models are being developed to predict PM2.5 exposures in relation to household and community level variables as well as to explore inter-relationships between household concentrations of PM2.5 and air toxics. Finally, a bio-repository of peripheral and cord blood samples is being created to explore the role of gene–environment interactions in follow-up studies. Ethics and dissemination The study protocols have been approved by the Institutional Ethics Committee of Sri Ramachandra University, the host institution for the investigators in this study. Study results will be widely disseminated through peer-reviewed publications and scientific presentations. In addition, policy-relevant recommendations are also being planned to inform ongoing national air quality action plans concerning ambient and household air pollution. PMID:26063570
Unice, Kenneth M; Kreider, Marisa L; Panko, Julie M
2012-11-08
Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raterman, G; Gauntt, D
2014-06-01
Purpose: To propose a method other than CTDI phantom measurements for routine CT dosimetry QA. This consists of taking a series of air exposure measurements and calculating a factor for converting from this exposure measurement to the protocol's associated head or body CTDI value using DLP. The data presented are the ratios of phantom DLP to air exposure ratios for different scanners, as well as error in the displayed CTDI. Methods: For each scanner, the CTDI is measured at all available tube voltages using both the head and body phantoms. Then, the exposure is measured using a pencil chamber inmore » air at isocenter. A ratio of phantom DLP to exposure in air for a given protocol may be calculated and used for converting a simple air dose measurement to a head or body CTDI value. For our routine QA, the exposure in air for different collimations, mAs, and kVp is measured, and displayed CTDI is recorded. Therefore, the ratio calculated may convert these exposures to CTDI values that may then be compared to the displayed CTDI for a large range of acquisition parameter combinations. Results: It was found that all scanners tend to have a ratio factor that slightly increases with kVp. Also, Philips scanners appear to have less of a dependence on kVp; whereas, GE scanners have a lower ratio at lower kVp. The use of air exposure times the DLP conversion yielded CTDI values that were less than 10% different from the displayed CTDI on several scanners. Conclusion: This method may be used as a primary method for CT dosimetry QA. As a result of the ease of measurement, a dosimetry metric specific to that scanner may be calculated for a wide variety of CT protocols, which could also be used to monitor display CTDI value accuracy.« less
Veillette, Marc; Knibbs, Luke D.; Pelletier, Ariane; Charlebois, Remi; Blais Lecours, Pascale; He, Congrong; Morawska, Lidia
2013-01-01
Vacuum cleaners can release large concentrations of particles, both in their exhaust air and from resuspension of settled dust. However, the size, variability, and microbial diversity of these emissions are unknown, despite evidence to suggest they may contribute to allergic responses and infection transmission indoors. This study aimed to evaluate bioaerosol emission from various vacuum cleaners. We sampled the air in an experimental flow tunnel where vacuum cleaners were run, and their airborne emissions were sampled with closed-face cassettes. Dust samples were also collected from the dust bag. Total bacteria, total archaea, Penicillium/Aspergillus, and total Clostridium cluster 1 were quantified with specific quantitative PCR protocols, and emission rates were calculated. Clostridium botulinum and antibiotic resistance genes were detected in each sample using endpoint PCR. Bacterial diversity was also analyzed using denaturing gradient gel electrophoresis (DGGE), image analysis, and band sequencing. We demonstrated that emission of bacteria and molds (Penicillium/Aspergillus) can reach values as high as 1E5 cell equivalents/min and that those emissions are not related to each other. The bag dust bacterial and mold content was also consistent across the vacuums we assessed, reaching up to 1E7 bacterial or mold cell equivalents/g. Antibiotic resistance genes were detected in several samples. No archaea or C. botulinum was detected in any air samples. Diversity analyses showed that most bacteria are from human sources, in keeping with other recent results. These results highlight the potential capability of vacuum cleaners to disseminate appreciable quantities of molds and human-associated bacteria indoors and their role as a source of exposure to bioaerosols. PMID:23934489
DOE Office of Scientific and Technical Information (OSTI.GOV)
Candela-Juan, C., E-mail: ccanjuan@gmail.com; Vijande, J.; García-Martínez, T.
2015-08-15
Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate ofmore » the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW chambers, differ by less than 1.1% for any applicator size when compared to the output factors that were measured with the A20 chamber. Conclusions: Measurements using both dosimetric protocols are consistent, once the overall uncertainties are considered. There is also consistency between measurements performed with both chambers calibrated in air. Both the T34013 and A20 chambers have negligible stem effect. Any x-ray surface brachytherapy system, including Esteya, can be characterized using either one of these calibration protocols and ionization chambers. Having less correction factors, lower uncertainty, and based on measurements, performed in closer to clinical conditions, the TRS-398 protocol seems to be the preferred option.« less
The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...
The international fine aerosol networks
NASA Astrophysics Data System (ADS)
Cahill, Thomas A.
1993-04-01
The adoption by the United States of a PIXE-based protocol for its fine aerosol network, after open competitions involving numerous laboratories and methods, has encouraged cooperation with other countries possessing similar capabilities and similar needs. These informal cooperative programs, involving about a dozen countries at the end of 1991, almost all use PIXE as a major component of the analytical protocols. The University of California, Davis, Air Quality Group assisted such programs through indefinite loans of a quality assurance sampler, the IMPROVE Channel A, and analyses at no cost of a small fraction of the samples taken in a side-by-side configuration. In December 1991, the World Meteorological Organization chose a protocol essentially identical to IMPROVE for the Global Atmospheric Watch (GAW) network and began deploying units, the IMPROVE Channel A, to sites around the world. Preferred analyses include fine (less than about 2.5 μm) mass, ions by ion chromatography and elements by PIXE + PESA (or, lacking that, XRF). This paper will describe progress in both programs, giving examples of the utility of the data and projecting the future expansion of the network to about 20 GAW sites by 1994.
Svendsen, Erik R; Reynolds, Scott; Ogunsakin, Olalekan A; Williams, Edith M; Fraser-Rahim, Herb; Zhang, Hongmei; Wilson, Sacoby M
2014-01-01
INTRODUCTION The Port of Charleston, one of the busiest US ports, currently operates five terminals. The fifth terminal is being planned for expansion to accommodate container ships from the proposed Panama Canal expansion. Such expansion is expected to increase traffic within local vulnerable North Charleston neck communities by at least 7,000 diesel truck trips per day, more than a 70% increase from the present average rate of 10,000 trucks per day. Our objective was to measure the current particulate matter (PM) concentrations in North Charleston communities as a baseline to contrast against future air pollution after the proposed port expansion. METHODS Saturation study was performed to determine spatial variability of PM in local Charleston neck communities. In addition, the temporal trends in particulate air pollution within the region were determined across several decades. With the BGI sampler, PM samples were collected for 24 hours comparable to the federal reference method protocol. Gravimetric analysis of the PM filter samples was conducted following EPA protocol. RESULTS The range of the PM10 annual average across the region from 1982 to 2006 was 17.0–55.0 μg/m3. On only two occasions were the records of PM10 averaged above the 50.0 μg/m3 national standard. In the case of PM2.5, the annual average for 1999–2006 ranged from 11.0 to 13.5 μg/m3 and no annual average exceeded the 15.0 μg/m3 PM2.5 annual standard. CONCLUSIONS Although ambient PM levels have fallen in the Charleston region since the 1960s due to aggressive monitoring by the stakeholders against air pollution, local air pollution sources within the North Charleston neck communities have consistently contributed to the PM levels in the region for several decades. This baseline assessment of ambient PM will allow for comparisons with future assessments to ascertain the impact of the increased truck and port traffic on PM concentrations. PMID:24653648
ENVIRONMENTAL TECHNOLOGY VERIFICATION FOR INDOOR AIR PRODUCTS
The paper discusses environmental technology verification (ETV) for indoor air products. RTI is developing the framework for a verification testing program for indoor air products, as part of EPA's ETV program. RTI is establishing test protocols for products that fit into three...
NASA Astrophysics Data System (ADS)
Roumie, M.; Chiari, M.; Srour, A.; Sa'adeh, H.; Reslan, A.; Sultan, M.; Ahmad, M.; Calzolai, G.; Nava, S.; Zubaidi, Th.; Rihawy, M. S.; Hussein, T.; Arafah, D.-E.; Karydas, A. G.; Simon, A.; Nsouli, B.
2016-03-01
The present work is a part of a scientific study conducted among several Arab countries in west Asia, under an International Atomic Energy Agency (IAEA) regional technical cooperation project for Arasia region. The project aims at producing for the first time a database of particulate matter (PM) elemental concentrations in the region that will help in future air quality studies in order to identify commonalities and differences in the presence and contribution of fingerprint pollution sources among the Arasia Member States. The first regional campaign was launched simultaneously in Lebanon, Iraq, Jordan, Syria and United Arab Emirates, using a harmonized sampling and analysis protocol of PM10 and PM2.5 samples. Different samples, collected between October 2014 and February 2015, from the participating countries, were analyzed by PIXE technique and gravimetric measurements were also carried out. The first results of the study will be discussed in a regional perspective. Our study shows that concentrations of fine aerosol fractions are often exceeding the WHO standard values as well as showing some disparities in the obtained values between the different sampling sites. However, some trend similarities of variations with time could also be observed, suggesting a common influence by trans-boundary or external sources of air pollution.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-19
... Protocol on Substances That Deplete the Ozone Layer (Protocol) and Title VI of the Clean Air Act Amendments (CAAA) established limits on total U.S. production, import, and export of class I and class II... transformed, destroyed, or exported to developing countries. The Protocol also establishes limits and...
EPA Protocol Gas Verification Program
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that co...
Buoyancy-corrected gravimetric analysis of lightly loaded filters.
Rasmussen, Pat E; Gardner, H David; Niu, Jianjun
2010-09-01
Numerous sources of uncertainty are associated with the gravimetric analysis of lightly loaded air filter samples (< 100 microg). The purpose of the study presented here is to investigate the effectiveness and limitations of air buoyancy corrections over experimentally adjusted conditions of temperature (21-25 degrees C) and relative humidity (RH) (16-60% RH). Conditioning (24 hr) and weighing were performed inside the Archimedes M3 environmentally controlled chamber. The measurements were performed using 20 size-fractionated samples of resuspended house dust loaded onto Teflo (PTFE) filters using a Micro-Orifice Uniform Deposit Impactor representing a wide range of mass loading (7.2-3130 microg) and cut sizes (0.056-9.9 microm). By maintaining tight controls on humidity (within 0.5% RH of control setting) throughout pre- and postweighing at each stepwise increase in RH, it was possible to quantify error due to water absorption: 45% of the total mass change due to water absorption occurred between 16 and 50% RH, and 55% occurred between 50 and 60% RH. The buoyancy corrections ranged from -3.5 to +5.8 microg in magnitude and improved relative standard deviation (RSD) from 21.3% (uncorrected) to 5.6% (corrected) for a 7.2 microg sample. It is recommended that protocols for weighing low-mass particle samples (e.g., nanoparticle samples) should include buoyancy corrections and tight temperature/humidity controls. In some cases, conditioning times longer than 24 hr may be warranted.
Santos, E M; Paula, J F R; Motta, P M C; Heinemann, M B; Leite, R C; Haddad, J P A; Del Puerto, H L; Reis, J K P
2010-08-17
We compared three different protocols for DNA extraction from horse peripheral blood mononuclear cells (PBMC) and lung fragments, determining average final DNA concentration, purity, percentage of PCR amplification using beta-actin, and cost. Thirty-four samples from PBMC, and 33 samples from lung fragments were submitted to DNA extraction by three different protocols. Protocol A consisted of a phenol-chloroform and isoamylic alcohol extraction, Protocol B used alkaline extraction with NaOH, and Protocol C used the DNAzol((R)) reagent kit. Protocol A was the best option for DNA extraction from lung fragments, producing high DNA concentrations, with high sensitivity in PCR amplification (100%), followed by Protocols C and B. On the other hand, for PBMC samples, Protocol B gave the highest sensitivity in PCR amplification (100%), followed by Protocols C and A. We conclude that Protocol A should be used for PCR diagnosis from lung fragment samples, while Protocol B should be used for PBMC.
Blanco-Marquizo, Adriana; Goja, Beatriz; Peruga, Armando; Jones, Miranda R; Yuan, Jie; Samet, Jonathan M; Breysse, Patrick N; Navas-Acien, Ana
2010-06-01
Smoke-free legislation eliminating tobacco smoke in all indoor public places and workplaces is the international standard to protect all people from exposure to secondhand smoke. Uruguay was the first country in the Americas and the first middle-income country in the world to enact a comprehensive smoke-free national legislation in March 2006. To compare air nicotine concentrations measured in indoor public places and workplaces in Montevideo, Uruguay before (November 2002) and after (July 2007) the implementation of the national legislation. Air nicotine concentrations were measured for 7-14 days using the same protocol in schools, a hospital, a local government building, an airport and restaurants and bars. A total of 100 and 103 nicotine samples were available in 2002 and 2007, respectively. Median (IQR) air nicotine concentrations in the study samples were 0.75 (0.2-1.54) microg/m(3) in 2002 compared to 0.07 (0.0-0.20) microg/m(3) in 2007. The overall nicotine reduction comparing locations sampled in 2007 to those sampled in 2002 was 91% (95% CI 85% to 94%) after adjustment for differences in room volume and ventilation. The greatest nicotine reduction was observed in schools (97% reduction), followed by the airport (94% reduction), the hospital (89% reduction), the local government building (86% reduction) and restaurants/bars (81% reduction). Exposure to secondhand smoke has decreased greatly in indoor public places and workplaces in Montevideo, Uruguay, after the implementation of a comprehensive national smoke-free legislation. These findings suggest that it is possible to successfully implement smoke-free legislations in low and middle-income countries.
Guidelines and sample protocol for sampling forest gaps.
J.R. Runkle
1992-01-01
A protocol for sampling forest canopy gaps is presented. Methods used in published gap studies are reviewed. The sample protocol will be useful in developing a broader understanding of forest structure and dynamics through comparative studies across different forest ecosystems.
Peering at Brain Polysomes with Atomic Force Microscopy
Lunelli, Lorenzo; Bernabò, Paola; Bolner, Alice; Vaghi, Valentina; Marchioretto, Marta; Viero, Gabriella
2016-01-01
The translational machinery, i.e., the polysome or polyribosome, is one of the biggest and most complex cytoplasmic machineries in cells. Polysomes, formed by ribosomes, mRNAs, several proteins and non-coding RNAs, represent integrated platforms where translational controls take place. However, while the ribosome has been widely studied, the organization of polysomes is still lacking comprehensive understanding. Thus much effort is required in order to elucidate polysome organization and any novel mechanism of translational control that may be embedded. Atomic force microscopy (AFM) is a type of scanning probe microscopy that allows the acquisition of 3D images at nanoscale resolution. Compared to electron microscopy (EM) techniques, one of the main advantages of AFM is that it can acquire thousands of images both in air and in solution, enabling the sample to be maintained under near physiological conditions without any need for staining and fixing procedures. Here, a detailed protocol for the accurate purification of polysomes from mouse brain and their deposition on mica substrates is described. This protocol enables polysome imaging in air and liquid with AFM and their reconstruction as three-dimensional objects. Complementary to cryo-electron microscopy (cryo-EM), the proposed method can be conveniently used for systematically analyzing polysomes and studying their organization. PMID:27023752
It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two…).
Rummel, John D; Kminek, Gerhard
2018-04-01
The last time NASA envisioned a sample return mission from Mars, the development of a protocol to support the analysis of the samples in a containment facility resulted in a "Draft Test Protocol" that outlined required preparations "for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth" (Rummel et al., 2002 ). This document comprised a specific protocol to be used to conduct a biohazard test for a returned martian sample, following the recommendations of the Space Studies Board of the US National Academy of Sciences. Given the planned launch of a sample-collecting and sample-caching rover (Mars 2020) in 2 years' time, and with a sample return planned for the end of the next decade, it is time to revisit the Draft Test Protocol to develop a sample analysis and biohazard test plan to meet the needs of these future missions. Key Words: Biohazard detection-Mars sample analysis-Sample receiving facility-Protocol-New analytical techniques-Robotic sample handling. Astrobiology 18, 377-380.
Healthy Indoor Environment Protocols for Home Energy Upgrades
This page contains the EPA-developed Healthy Indoor Environment Protocols for Home Energy Upgrades, a PDF guide that provides a set of best practices for improving indoor air quality in conjunction with energy upgrade work in homes.
NASA Astrophysics Data System (ADS)
Yang, M. M.; Meinardi, S.; Krauter, C.; Blake, D.
2008-12-01
The San Joaquin Valley Air Basin in Central California is classified by the U.S. Environmental Protection Agency (EPA) as a serious non-attainment area for health-based eight-hour federal ozone (smog) standard (1). In August 2005, the San Joaquin Valley Air Pollution Control District issued a report identifying dairies as a main source of Volatile Organic Compounds (VOCs) and fine particulate matter in the valley (2). Among these compounds, we have found that ethanol, methanol, acetone and acetaldehyde are produced in major quantities throughout the San Joaquin valley as by-products of yeast fermentation of silage and photochemical oxidation. These oxygenates, especially ethanol, play an important role in ozone (O3) formation within the valley. Three different types of sampling protocols were employed in order to determine the degree of enhancement of the four oxygenates in the valley air shed, as well as to determine their sources, emission profiles and emission rates. An assessment of the emissions of these oxygenates in the valley was achieved using data obtained on low altitude flights through the valley and from ground level samples collected thoughout the valley. The photochemical production of ozone was calculated for each of the four oxygenates and approximately one hundred other quantified VOCs. Based on the Maximum Incremental Reactivity (MIR) scale and concentrations of each oxygenate in the atmosphere, as much as 20% of O3 production in the valley is from ethanol and its photochemical by-product acetaldehyde. Our findings suggest that improvement to the valley air quality may be obtained by focusing on instituting new silage containment practices and regulations. 1. Lindberg, J. "Analysis of the San Joaquin Valley 2007 Ozone Plan." State of California Air Resources Board. Final Draft Staff Report. 5/30/2007. 2. Crow, D., executive director/APCO. "Air Pollution Control Officer's Determination of VOC Emisison Factors for Dairies." San Joaquin Valley Air Pollution Control District. Aug. 1st 2005.
The Earth Microbiome Project and modeling the planets microbial potential (Invited)
NASA Astrophysics Data System (ADS)
Gilbert, J. A.
2013-12-01
The understanding of Earth's climate and ecology requires multiscale observations of the biosphere, of which microbial life are a major component. However, to acquire and process physical samples of soil, water and air that comprise the appropriate spatial and temporal resolution to capture the immense variation in microbial dynamics, would require a herculean effort and immense financial resources dwarfing even the most ambitious projects to date. To overcome this hurdle we created the Earth Microbiome Project, a crowd-sourced effort to acquire physical samples from researchers around the world that are, importantly, contextualized with physical, chemical and biological data detailing the environmental properties of that sample in the location and time it was acquired. The EMP leverages these existing efforts to target a systematic analysis of microbial taxonomic and functional dynamics across a vast array of environmental parameter gradients. The EMP captures the environmental gradients, location, time and sampling protocol information about every sample donated by our valued collaborators. Physical samples are then processed using a standardized DNA extraction, PCR, and shotgun sequencing protocol to generate comparable data regarding the microbial community structure and function in each sample. To date we have processed >17,000 samples from 40 different biomes. One of the key goals of the EMP is to map the spatiotemporal variability of microbial communities to capture the changes in important functional processes that need to be appropriately expressed in models to provide reliable forecasts of ecosystem phenotype across our changing planet. This is essential if we are to develop economically sound strategies to be good stewards of our Earth. The EMP recognizes that environments are comprised of complex sets of interdependent parameters and that the development of useful predictive computational models of both terrestrial and atmospheric systems requires recognition and accommodation of sources of uncertainty.
Speciated arsenic in air: measurement methodology and risk assessment considerations.
Lewis, Ari S; Reid, Kim R; Pollock, Margaret C; Campleman, Sharan L
2012-01-01
Accurate measurement of arsenic (As) in air is critical to providing a more robust understanding of arsenic exposures and associated human health risks. Although there is extensive information available on total arsenic in air, less is known on the relative contribution of each arsenic species. To address this data gap, the authors conducted an in-depth review of available information on speciated arsenic in air. The evaluation included the type of species measured and the relative abundance, as well as an analysis of the limitations of current analytical methods. Despite inherent differences in the procedures, most techniques effectively separated arsenic species in the air samples. Common analytical techniques such as inductively coupled plasma mass spectrometry (ICP-MS) and/or hydride generation (HG)- or quartz furnace (GF)-atomic absorption spectrometry (AAS) were used for arsenic measurement in the extracts, and provided some of the most sensitive detection limits. The current analysis demonstrated that, despite limited comparability among studies due to differences in seasonal factors, study duration, sample collection methods, and analytical methods, research conducted to date is adequate to show that arsenic in air is mainly in the inorganic form. Reported average concentrations of As(III) and As(V) ranged up to 7.4 and 10.4 ng/m3, respectively, with As(V) being more prevalent than As(III) in most studies. Concentrations of the organic methylated arsenic compounds are negligible (in the pg/m3 range). However because of the variability in study methods and measurement methodology, the authors were unable to determine the variation in arsenic composition as a function of source or particulate matter (PM) fraction. In this work, the authors include the implications of arsenic speciation in air on potential exposure and risks. The authors conclude that it is important to synchronize sample collection, preparation, and analytical techniques in order to generate data more useful for arsenic inhalation risk assessment, and a more robust documentation of quality assurance/quality control (QA/QC) protocols is necessary to ensure accuracy, precision, representativeness, and comparability.
Portnuff, Cory D F; Kleindienst, Samantha; Bogle, Jamie M
2017-09-01
Vestibular-evoked myogenic potentials (VEMPs) are commonly used clinical assessments for patients with complaints of dizziness. However, relatively high air-conducted stimuli are required to elicit the VEMP, and ultimately may compromise safe noise exposure limits. Recently, research has reported the potential for noise-induced hearing loss (NIHL) from VEMP stimulus exposure through studies of reduced otoacoustic emission levels after VEMP testing, as well as a recent case study showing permanent sensorineural hearing loss associated with VEMP exposure. The purpose of this report is to review the potential for hazardous noise exposure from VEMP stimuli and to suggest clinical parameters for safe VEMP testing. Literature review with presentation of clinical guidelines and a clinical tool for estimating noise exposure. The literature surrounding VEMP stimulus-induced hearing loss is reviewed, including several cases of overexposure. The article then presents a clinical calculation tool for the estimation of a patient's safe noise exposure from VEMP stimuli, considering stimulus parameters, and includes a discussion of how varying stimulus parameters affect a patient's noise exposure. Finally, recommendations are provided for recognizing and managing specific patient populations who may be at higher risk for NIHL from VEMP stimulus exposure. A sample protocol is provided that allows for safe noise exposure. VEMP stimuli have the potential to cause NIHL due to high sound exposure levels. However, with proper safety protocols in place, clinicians may reduce or eliminate this risk to their patients. Use of the tools provided, including the noise exposure calculation tool and sample protocols, may help clinicians to understand and ensure safe use of VEMP stimuli. American Academy of Audiology
Instrumental neutron activation analysis for studying size-fractionated aerosols
NASA Astrophysics Data System (ADS)
Salma, Imre; Zemplén-Papp, Éva
1999-10-01
Instrumental neutron activation analysis (INAA) was utilized for studying aerosol samples collected into a coarse and a fine size fraction on Nuclepore polycarbonate membrane filters. As a result of the panoramic INAA, 49 elements were determined in an amount of about 200-400 μg of particulate matter by two irradiations and four γ-spectrometric measurements. The analytical calculations were performed by the absolute ( k0) standardization method. The calibration procedures, application protocol and the data evaluation process are described and discussed. They make it possible now to analyse a considerable number of samples, with assuring the quality of the results. As a means of demonstrating the system's analytical capabilities, the concentration ranges, median or mean atmospheric concentrations and detection limits are presented for an extensive series of aerosol samples collected within the framework of an urban air pollution study in Budapest. For most elements, the precision of the analysis was found to be beyond the uncertainty represented by the sampling techniques and sample variability.
2018 EPA Protocol Gas Verification Program Participants
A list of participants for 2016 EPA's Protocol Gas Verification Program (PGVP) for stationary source monitoring. The list also has vendor IDs, which are production site-specific, and are the same ones used in the PGVP for ambient air monitoring.
Current Status of EPA Protocol Gas Verification Program
Accurate compressed gas reference standards are needed to calibrate and audit continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensur...
Sampling protocol for post-landfall Deepwater Horizon oil release, Gulf of Mexico, 2010
Wilde, F.D.; Skrobialowski, S.C.; Hart, J.S.
2010-01-01
The protocols and procedures described in this report are designed to be used by U.S. Geological Survey (USGS) field teams for the collection of environmental data and samples in coastal areas affected by the 2010 Deepwater Horizon oil spill in the Gulf of Mexico. This sampling protocol focuses specifically on sampling for water, sediments, benthic invertebrates, and microorganisms (ambient bacterial populations) after shoreline arrival of petroleum-associated product on beach, barrier island, and wetland environments of the Gulf of Mexico coastal states. Deployment to sampling sites, site setup, and sample collection in these environments necessitates modifications to standard USGS sampling procedures in order to address the regulatory, logistical, and legal requirements associated with samples collected in oil-impacted coastal areas. This document, therefore, has been written as an addendum to the USGS National Field Manual for the Collection of Water-Quality Data (NFM) (http://pubs.water.usgs.gov/twri9A/), which provides the basis for training personnel in the use of standard USGS sampling protocols. The topics covered in this Gulf of Mexico oil-spill sampling protocol augment NFM protocols for field-deployment preparations, health and safety precautions, sampling and quality-assurance procedures, and decontamination requirements under potentially hazardous environmental conditions. Documentation procedures and maintenance of sample integrity by use of chain-of-custody procedures also are described in this protocol.
Mars Sample Handling Protocol Workshop Series: Workshop 4
NASA Technical Reports Server (NTRS)
Race Margaret S. (Editor); DeVincenzi, Donald L. (Editor); Rummel, John D. (Editor); Acevedo, Sara E. (Editor)
2001-01-01
In preparation for missions to Mars that will involve the return of samples to Earth, it will be necessary to prepare for the receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but specific detailed protocols for the handling and testing of returned samples must still be developed. To further refine the requirements for sample hazard testing and to develop the criteria for subsequent release of sample materials from quarantine, the NASA Planetary Protection Officer convened a series of workshops in 2000-2001. The overall objective of the Workshop Series was to produce a Draft Protocol by which returned martian sample materials can be assessed for biological hazards and examined for evidence of life (extant or extinct) while safeguarding the purity of the samples from possible terrestrial contamination. This report also provides a record of the proceedings of Workshop 4, the final Workshop of the Series, which was held in Arlington, Virginia, June 5-7, 2001. During Workshop 4, the sub-groups were provided with a draft of the protocol compiled in May 2001 from the work done at prior Workshops in the Series. Then eight sub-groups were formed to discuss the following assigned topics: Review and Assess the Draft Protocol for Physical/Chemical Testing Review and Assess the Draft Protocol for Life Detection Testing Review and Assess the Draft Protocol for Biohazard Testing Environmental and Health/Monitoring and Safety Issues Requirements of the Draft Protocol for Facilities and Equipment Contingency Planning for Different Outcomes of the Draft Protocol Personnel Management Considerations in Implementation of the Draft Protocol Draft Protocol Implementation Process and Update Concepts This report provides the first complete presentation of the Draft Protocol for Mars Sample Handling to meet planetary protection needs. This Draft Protocol, which was compiled from deliberations and recommendations from earlier Workshops in the Series, represents a consensus that emerged from the discussions of all the sub-groups assembled over the course of the five Workshops of the Series. These discussions converged on a conceptual approach to sample handling, as well as on specific analytical requirements. Discussions also identified important issues requiring attention, as well as research and development needed for protocol implementation.
Poster — Thur Eve — 20: CTDI Measurements using a Radiochromic Film-based clinical protocol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quintero, C.; Bekerat, H.; DeBlois, F.
2014-08-15
The purpose of the study was evaluating accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV-CBCT systems attached to linear accelerators. Energy dependence of Gafchromic XR-QA2 ® film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air-kerma (up to 10 cGy). Calibration curves for each beam quality were created (Film reflectance change Vs. Air-kerma in air). Film responses for same air-kerma values were compared. Film strips were placed into holesmore » of a CTDI phantom and irradiated for several clinical scanning protocols. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured and tabulated CTDIvol values were compared. Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. Measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Results presented a mean variation for the same machine and protocol of 2.6%. Variation of film response is within ±5% resulting in ±15% systematic error in dose estimation if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom, as suggested by TG- 111.« less
Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait.
Al-Matawah, Qadreyah; Al-Zenki, Sameer; Al-Azmi, Ahmad; Al-Waalan, Tahani; Al-Salameen, Fadila; Hejji, Ahmad Ben
2015-07-01
The main aim of the study was to test for the presence of Legionnaires' disease-causing microorganisms in air-conditioned buildings in Kuwait using molecular technologies. For this purpose, 547 samples were collected from 38 cooling towers for the analysis of Legionella pneumophila. These samples included those from water (n = 178), air (n = 231), and swabs (n = 138). Out of the 547 samples, 226 (41%) samples were presumptive positive for L. pneumophila, with L. pneumophila viable counts in the positive water samples ranging from 1 to 88 CFU/ml. Of the Legionella culture-positive samples, 204 isolates were examined by latex agglutination. These isolates were predominately identified as L. pneumophila serogroup (sg) 2-14. Using the Dresden panel of monoclonal antibodies, 74 representatives isolates were further serogrouped. Results showed that 51% of the isolates belonged to serogroup 7 followed by 1 (18%) and 3 (18%). Serogroups 4 (4%) and 10 (7%) were isolated at a lower frequency, and two isolates could not be assigned to a serogroup. These results indicate the wide prevalence of L. pneumophila serogroup 7 as the predominant serogroup at the selected sampling sites. Furthermore, the 74 L. pneumophila (sg1 = 13; sg3 = 13; sg4 = 3; sg7 = 38; sg10 = 5; sgX = 2) isolates were genotyped using the seven gene protocol sequence-based typing (SBT) scheme developed by the European Working Group for Legionella Infections (EWGLI). The results show that Legionella isolates were discriminated into nine distinct sequence typing (ST) profiles, five of which were new to the SBT database of EWGLI. Additionally, all of the ST1 serogroup 1 isolates were of the OLDA/Oxford subgroup. These baseline data will form the basis for the development of a Legionella environmental surveillance program and used for future epidemiological investigations.
Transitioning to Low-GWP Alternatives in Unitary Air Conditioning
This fact sheet provides current information on low-Global Warming Potential (GWP) refrigerant alternatives used in unitary air-conditioning equipment, relevant to the Montreal Protocol on Substances that Deplete the Ozone Layer.
Unice, Kenneth M.; Kreider, Marisa L.; Panko, Julie M.
2012-01-01
Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories. PMID:23202830
Evaluation of storage and filtration protocols for alpine/subalpine lake water quality samples
John L. Korfmacher; Robert C. Musselman
2007-01-01
Many government agencies and other organizations sample natural alpine and subalpine surface waters using varying protocols for sample storage and filtration. Simplification of protocols would be beneficial if it could be shown that sample quality is unaffected. In this study, samples collected from low ionic strength waters in alpine and subalpine lake inlets...
Balakrishnan, Kalpana; Sambandam, Sankar; Ramaswamy, Padmavathi; Ghosh, Santu; Venkatesan, Vettriselvi; Thangavel, Gurusamy; Mukhopadhyay, Krishnendu; Johnson, Priscilla; Paul, Solomon; Puttaswamy, Naveen; Dhaliwal, Rupinder S; Shukla, D K
2015-06-10
In rapidly developing countries such as India, the ubiquity of air pollution sources in urban and rural communities often results in ambient and household exposures significantly in excess of health-based air quality guidelines. Few efforts, however, have been directed at establishing quantitative exposure-response relationships in such settings. We describe study protocols for The Tamil Nadu Air Pollution and Health Effects (TAPHE) study, which aims to examine the association between fine particulate matter (PM2.5) exposures and select maternal, child and adult health outcomes in integrated rural-urban cohorts. The TAPHE study is organised into five component studies with participants drawn from a pregnant mother-child cohort and an adult cohort (n=1200 participants in each cohort). Exposures are assessed through serial measurements of 24-48 h PM2.5 area concentrations in household microenvironments together with ambient measurements and time-activity recalls, allowing exposure reconstructions. Generalised additive models will be developed to examine the association between PM2.5 exposures, maternal (birth weight), child (acute respiratory infections) and adult (chronic respiratory symptoms and lung function) health outcomes while adjusting for multiple covariates. In addition, exposure models are being developed to predict PM2.5 exposures in relation to household and community level variables as well as to explore inter-relationships between household concentrations of PM2.5 and air toxics. Finally, a bio-repository of peripheral and cord blood samples is being created to explore the role of gene-environment interactions in follow-up studies. The study protocols have been approved by the Institutional Ethics Committee of Sri Ramachandra University, the host institution for the investigators in this study. Study results will be widely disseminated through peer-reviewed publications and scientific presentations. In addition, policy-relevant recommendations are also being planned to inform ongoing national air quality action plans concerning ambient and household air pollution. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
7 CFR 301.92-11 - Inspection and sampling protocols.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 5 2010-01-01 2010-01-01 false Inspection and sampling protocols. 301.92-11 Section... Inspection and sampling protocols. Type(s) of plants in the nursery Type(s) of plants shipped interstate... interstate. (1) Annual inspection, sampling, and testing—(i) Inspection. The nursery must be inspected...
7 CFR 301.92-11 - Inspection and sampling protocols.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 5 2011-01-01 2011-01-01 false Inspection and sampling protocols. 301.92-11 Section... Inspection and sampling protocols. Type(s) of plants in the nursery Type(s) of plants shipped interstate... interstate. (1) Annual inspection, sampling, and testing—(i) Inspection. The nursery must be inspected...
Scripted drives: A robust protocol for generating exposures to traffic-related air pollution
NASA Astrophysics Data System (ADS)
Patton, Allison P.; Laumbach, Robert; Ohman-Strickland, Pamela; Black, Kathy; Alimokhtari, Shahnaz; Lioy, Paul J.; Kipen, Howard M.
2016-10-01
Commuting in automobiles can contribute substantially to total traffic-related air pollution (TRAP) exposure, yet measuring commuting exposures for studies of health outcomes remains challenging. To estimate real-world TRAP exposures, we developed and evaluated the robustness of a scripted drive protocol on the NJ Turnpike and local roads between April 2007 and October 2014. Study participants were driven in a car with closed windows and open vents during morning rush hours on 190 days. Real-time measurements of PM2.5, PNC, CO, and BC, and integrated samples of NO2, were made in the car cabin. Exposure measures included in-vehicle concentrations on the NJ Turnpike and local roads and the differences and ratios of these concentrations. Median in-cabin concentrations were 11 μg/m3 PM2.5, 40 000 particles/cm3, 0.3 ppm CO, 4 μg/m3 BC, and 20.6 ppb NO2. In-cabin concentrations on the NJ Turnpike were higher than in-cabin concentrations on local roads by a factor of 1.4 for PM2.5, 3.5 for PNC, 1.0 for CO, and 4 for BC. Median concentrations of NO2 for full rides were 2.4 times higher than ambient concentrations. Results were generally robust relative to season, traffic congestion, ventilation setting, and study year, except for PNC and PM2.5, which had secular and seasonal trends. Ratios of concentrations were more stable than differences or absolute concentrations. Scripted drives can be used to generate reasonably consistent in-cabin increments of exposure to traffic-related air pollution.
Scripted drives: A robust protocol for generating exposures to traffic-related air pollution
Patton, Allison P.; Laumbach, Robert; Ohman-Strickland, Pamela; Black, Kathy; Alimokhtari, Shahnaz; Lioy, Paul; Kipen, Howard M.
2016-01-01
Commuting in automobiles can contribute substantially to total traffic-related air pollution (TRAP) exposure, yet measuring commuting exposures for studies of health outcomes remains challenging. To estimate real-world TRAP exposures, we developed and evaluated the robustness of a scripted drive protocol on the NJ Turnpike and local roads between April 2007 and October 2014. Study participants were driven in a car with closed windows and open vents during morning rush hours on 190 days. Real-time measurements of PM2.5, PNC, CO, and BC, and integrated samples of NO2, were made in the car cabin. Exposure measures included in-vehicle concentrations on the NJ Turnpike and local roads and the differences and ratios of these concentrations. Median in-cabin concentrations were 11 μg/m3 PM2.5, 40 000 particles/cm3, 0.3 ppm CO, 4 μg/m3 BC, and 20.6 ppb NO2. In-cabin concentrations on the NJ Turnpike were higher than in-cabin concentrations on local roads by a factor of 1.4 for PM2.5, 3.5 for PNC, 1.0 for CO, and 4 for BC. Median concentrations of NO2 for full rides were 2.4 times higher than ambient concentrations. Results were generally robust relative to season, traffic congestion, ventilation setting, and study year, except for PNC and PM2.5, which had secular and seasonal trends. Ratios of concentrations were more stable than differences or absolute concentrations. Scripted drives can be used for generating reasonably consistent in-cabin increments of exposure to traffic-related air pollution. PMID:27642251
NASA Technical Reports Server (NTRS)
Haines, Jennifer C.; Chen, Lung-Wen A.; Taubman, Brett F.; Doddridge, Bruce G.; Dickerson, Russell R.
2007-01-01
Reliable determination of the effects of air quality on public health and the environment requires accurate measurement of PM(sub 2.5) mass and the individual chemical components of fine aerosols. This study seeks to evaluate PM(sub 2.5) measurements that are part of a newly established national network by comparing them with a more conventional sampling system. Experiments were carried out during 2002 at a suburban site in Maryland, United States, where two samplers from the U.S. Environmental Protection Agency (USEPA) Speciation Trends Network: Met One Speciation Air Sampling System STNS and Thermo Scientific Reference Ambient Air Sampler STNR, two Desert Research Institute Sequential Filter Samplers DRIF, and a continuous TEOM monitor (Thermo Scientific Tapered Element Oscillating Microbalance) were sampling air in parallel. These monitors differ not only in sampling configuration but also in protocol-specific sample analysis procedures. Measurements of PM(sub 2.5) mass and major contributing species were well correlated among the different methods with r-values > 0.8. Despite the good correlations, daily concentrations of PM(sub 2.5) mass and major contributing species were significantly different at the 95% confidence level from 5 to 100% of the time. Larger values of PM(sub 2.5) mass and individual species were generally reported from STNR and STNS. The January STNR average PM(sub 2.5) mass (8.8 (micro)g/per cubic meter) was 1.5 (micro)g/per cubic meter larger than the DRIF average mass. The July STNS average PM(sub 2.5) mass (27.8 (micro)g/per cubic meter) was 3.8 (micro)g/per cubic meter larger than the DRIF average mass. These differences can only be partially accounted for by known random errors. Variations in flow control, face velocity, and sampling artifacts likely influence the measurement of PM(sub 2.5) speciation and mass closure. Simple statistical tests indicate that the current uncertainty estimates used in the STN network may underestimate the actual uncertainty.
Realization of Long-Term Air Stability in the Organic Magnet Vanadium Tetracyanoethylene
NASA Astrophysics Data System (ADS)
Froning, Ian; Harberts, Megan; Lu, Yu; Yu, Howard; Epstein, Arthur J.; Johnston-Halperin, Ezekiel
2015-03-01
The organic ferrimagnet vanadium tetracyanoethylene (V[TCNE]x) has potential uses in both microwave electronics and spintronics due to the combination of high temperature magnetic ordering (TC >600 K), extremely sharp ferromagnetic resonance (peak to peak linewidth of 1 G), and low-temperature conformal deposition via chemical vapor deposition (CVD; deposition temperature of 50 C), but air-sensitivity leads to the complete degradation of the films within 2 hours under ambient conditions. We have encapsulated thin films of V[TCNE]x using a UV-cured epoxy that increases film lifetime to over 700 hours as measured by the remanent magnetization. The saturation magnetization and Curie temperature decay more slowly than the remanence, and the coercivity is unchanged after 340 hours of air exposure. Fourier transform infrared spectroscopy (FTIR) shows that the epoxy does not react with the film, and magnetometry measurements show that the epoxy does not impact bulk magnetic properties. This encapsulation strategy enables experimental protocols and investigations that were not previously possible for air-sensitive samples and points the way toward the development of practical applications for this promising organic-based magnetic material. Supported by NSF Grant DMR 1207243, and the NanoSystems Laboratory at the Ohio State University.
CURRENT STATUS OF THE EPA PROTOCOL GAS PROGRAM
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. EPA has published a protocol to establish the traceability of these standards to national refer...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-08
... Protocol Gas Verification Program; EPA ICR No. 2375.01, OMB Control Number 2060-NEW AGENCY: Environmental... Air Protocol Gas Verification Program. ICR numbers: EPA ICR No. 2375.01, OMB Control No. 2060-NEW. ICR...
Current Status of EPA Verification Program for EPA Protocol Gases
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...
EPA Protocol Gas Verification Program - Presented at NIST Gas Panel Meeting
Accurate compressed gas calibration standards are needed to calibrate continuous emission monitors (CEMs) and ambient air quality monitors that are being used for regulatory purposes. US Environmental Protection Agency (EPA) established its traceability protocol to ensure that c...
Hoffmayer, Eric R; Hendon, Jill M; Parsons, Glenn R; Driggers, William B; Campbell, Matthew D
2015-10-01
Elasmobranch stress responses are traditionally measured in the field by either singly or serially sampling an animal after a physiologically stressful event. Although capture and handling techniques are effective at inducing a stress response, differences in protocols could affect the degree of stress experienced by an individual, making meaningful comparisons between the protocols difficult, if not impossible. This study acutely stressed Atlantic sharpnose sharks, Rhizoprionodon terraenovae, by standardized capture (rod and reel) and handling methods and implemented either a single or serial blood sampling protocol to monitor four indicators of the secondary stress response. Single-sampled sharks were hooked and allowed to swim around the boat until retrieved for a blood sample at either 0, 15, 30, 45, or 60 min post-hooking. Serially sampled sharks were retrieved, phlebotomized, released while still hooked, and subsequently resampled at 15, 30, 45, and 60 min intervals post-hooking. Blood was analyzed for hematocrit, and plasma glucose, lactate, and osmolality levels. Although both single and serial sampling protocols resulted in an increase in glucose, no significant difference in glucose level was found between protocols. Serially sampled sharks exhibited cumulatively heightened levels for lactate and osmolality at all time intervals when compared to single-sampled animals at the same time. Maximal concentration differences of 217.5, 9.8, and 41.6 % were reported for lactate, osmolality, and glucose levels, respectively. Hematocrit increased significantly over time for the single sampling protocol but did not change significantly during the serial sampling protocol. The differences in resultant blood chemistry levels between implemented stress protocols and durations are significant and need to be considered when assessing stress in elasmobranchs.
NASA Astrophysics Data System (ADS)
Vuppala, P.; S. S, A.; Mareddy, A.
2004-12-01
Around the world cities in developing countries are rapidly growing as more and more people become urban dwellers resulting in increased level of air pollution caused by changes in transportation, energy production and industrial activities. Air quality is an issue of critical importance in view of the accumulating evidence showing the adverse effects of pollution on human health, agricultural crops, manmade environments and ecosystems. An integrated study for identification of appropriate sites for representative evaluation of air pollution, novel means of monitoring air quality, identifying the predominant sources of pollution, effective assessment of air quality and evaluation of different management strategies essential for the development of a healthy and livable region is carried out for Hyderabad metropolis in India using Remote sensing and Geographical Information System (GIS) based assessment tools. Correlation studies between the concentration level of pollutants in urban air and urban land use are also dealt with. Municipal Corporation of Hyderabad (MCH) is divided into eleven planning zones out of which the present study area i.e. Zone I & IIA comprises of industrial, highly commercial and densely populated areas, apart from medium and sparse residential areas making it environmentally sensitive. Sampling locations were identified based on the land use/ land cover of the region and air samples were collected from areas having varying land use patterns using a high volume air sampler. The samples were then analyzed for the presence of Sulphur oxides(SO--x), Oxides of Nitrogen(NO--x), Total Suspended Particulate Matter(TSPM) and Respirable Suspended Particulate Matter(RSPM) using standard protocols and maps showing spatial distribution of SOx, NO--x, TSPM & RSPM were prepared using curve fitting technique of Arc/Info & ArcView GIS software. Air Quality Index (AQI), indicating the overall quality of air and extent of pollution is also calculated, based on which the entire study area is classified into severely, highly, moderately and lightly polluted areas. Concentration of SOx and NOx were observed to be within limits, while particulate pollutants exceeded the standards prescribed by Central Pollution Control Board (CPCB). The major cause of pollution in the study area is attributed to the increasing vehicular movements and presence of commercial and public related activities such as shopping malls. It is observed for the category of severe air pollution that 42% of pollution is from dense residential areas, 19% from medium residential and 1% load of pollution from other public related activities. Based on the results obtained suitable remedial measures to combat the increasing urban air pollution are suggested in the study area. Key words: Air pollution, Remote sensing, Geographical Information System, Spatial distribution, Air quality index.
A Draft Test Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Rummel, John D. (Editor); Race, Margaret S.; DeVincenzi, Donald L.; Schad, P. Jackson; Stabekis, Pericles D.; Viso, Michel; Acevedo, Sara E.
2002-01-01
This document presents the first complete draft of a protocol for detecting possible biohazards in Mars samples returned to Earth: it is the final product of the Mars Sample Handling Protocol Workshop Series. convened in 2000-2001 by NASA's Planetary Protection Officer. The goal of the five-workshop Series vas to develop a comprehensive protocol by which returned martian sample materials could be assessed k r the presence of any biological hazard(s) while safeguarding the purity of the samples from possible terrestrial contamination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drzymala, R; Alvarez, P; Bednarz, G
2015-06-15
Purpose: The purpose of this multi-institutional study was to compare two new gamma stereotactic radiosurgery (GSRS) dosimetry protocols to existing calibration methods. The ultimate goal was to guide AAPM Task Group 178 in recommending a standard GSRS dosimetry protocol. Methods: Nine centers (ten GSRS units) participated in the study. Each institution made eight sets of dose rate measurements: six with two different ionization chambers in three different 160mm-diameter spherical phantoms (ABS plastic, Solid Water and liquid water), and two using the same ionization chambers with a custom in-air positioning jig. Absolute dose rates were calculated using a newly proposed formalismmore » by the IAEA working group for small and non-standard radiation fields and with a new air-kerma based protocol. The new IAEA protocol requires an in-water ionization chamber calibration and uses previously reported Monte-Carlo generated factors to account for the material composition of the phantom, the type of ionization chamber, and the unique GSRS beam configuration. Results obtained with the new dose calibration protocols were compared to dose rates determined by the AAPM TG-21 and TG-51 protocols, with TG-21 considered as the standard. Results: Averaged over all institutions, ionization chambers and phantoms, the mean dose rate determined with the new IAEA protocol relative to that determined with TG-21 in the ABS phantom was 1.000 with a standard deviation of 0.008. For TG-51, the average ratio was 0.991 with a standard deviation of 0.013, and for the new in-air formalism it was 1.008 with a standard deviation of 0.012. Conclusion: Average results with both of the new protocols agreed with TG-21 to within one standard deviation. TG-51, which does not take into account the unique GSRS beam configuration or phantom material, was not expected to perform as well as the new protocols. The new IAEA protocol showed remarkably good agreement with TG-21. Conflict of Interests: Paula Petti, Josef Novotny, Gennady Neyman and Steve Goetsch are consultants for Elekta Instrument A/B; Elekta Instrument AB, PTW Freiburg GmbH, Standard Imaging, Inc., and The Phantom Laboratory, Inc. loaned equipment for use in these experiments; The University of Wisconsin Accredited Dosimetry Calibration Laboratory provided calibration services.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-03
... assess the performance of an approved sampling protocol and to allow for continued sample collection and... developmental sampling protocol. While this application was being reviewed and was available for public comment, the sampling protocol being tested was adopted into the National Shellfish Sanitation Program by the...
NASA Technical Reports Server (NTRS)
Feedback, Daniel L.; Cibuzar, Branelle R.
2009-01-01
The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.
Serrano-Silva, N; Calderón-Ezquerro, M C
2018-04-01
The identification of airborne bacteria has traditionally been performed by retrieval in culture media, but the bacterial diversity in the air is underestimated using this method because many bacteria are not readily cultured. Advances in DNA sequencing technology have produced a broad knowledge of genomics and metagenomics, which can greatly improve our ability to identify and study the diversity of airborne bacteria. However, researchers are facing several challenges, particularly the efficient retrieval of low-density microorganisms from the air and the lack of standardized protocols for sample collection and processing. In this study, we tested three methods for sampling bioaerosols - a Durham-type spore trap (Durham), a seven-day recording volumetric spore trap (HST), and a high-throughput 'Jet' spore and particle sampler (Jet) - and recovered metagenomic DNA for 16S rDNA sequencing. Samples were simultaneously collected with the three devices during one week, and the sequencing libraries were analyzed. A simple and efficient method for collecting bioaerosols and extracting good quality DNA for high-throughput sequencing was standardized. The Durham sampler collected preferentially Cyanobacteria, the HST Actinobacteria, Proteobacteria and Firmicutes, and the Jet mainly Proteobacteria and Firmicutes. The HST sampler collected the largest amount of airborne bacterial diversity. More experiments are necessary to select the right sampler, depending on study objectives, which may require monitoring and collecting specific airborne bacteria. Copyright © 2017 Elsevier Ltd. All rights reserved.
Detecting Hidden Communications Protocols
2013-02-11
Protocols FA9550-09-1-0173 Richard R Brooks Clemson University PO Box 340915 Clemson, SC 29634-0915 Air Force Office of Scientific Research/RSL 875...two botnet detection methods: centralized botnet traffic detection using HMMs and probabilistic context-free grammars (PCFGs) for centralized and...final report for the Detecting Hidden Communications Protocols AFOSR grant with R. R. Brooks form Clemson University as PI. The work funded by the
Enhanced Characterization of Microorganisms in the Spacecraft Environment
NASA Technical Reports Server (NTRS)
Cruz, Patricia; Stetzenbach, Linda D.
2004-01-01
Spacecraft such as the International Space Station (ISS) and the space shuttles are enclosed environments where crewmembers may spend long periods of time. Currently, crewmembers spend approximately a period of 6 months in the ISS. It is known that these prolonged stays in space may result in weakening of the immune system. Therefore, exposure to opportunistic pathogens or high concentrations of environmental microorganisms may compromise the health of the crew. The detection of biocontaminants in spacecraft environments utilizes culture-based methodology, omitting greater than 90% of all microorganisms including pathogens such as Legionella and Cryptosporidium. Culturable bacteria and fungi have been the only allergens studied; the more potent allergens, such as those from dust mites, have never been tested for in spacecraft environments. In addition, no attempts have been made to monitor microbial toxins in spacecrafts. The present study utilized quantitative polymerase chain reaction (QPCR) as a novel approach for monitoring microorganisms in the spacecraft environment. QPCR is a molecular biology technique that does not rely on the physiological state of the organisms for identification, thereby enabling detection of both culturable and non-culturable organisms. In this project, specific molecular primers and probes were utilized for the detection and quantitation of two fungi of concern in indoor environments, Aspergillus fumigatus and Stachybotrys chartarum. These organisms were selected because of the availability of PCR primers and probes, and to establish the sample processing and analysis methodology that may be employed with additional organisms. Purification methods and QPCR assays were optimized for the detection of these organisms in air, surface, and water; and sample processing and analysis protocols were developed. Preliminary validation of these protocols was conducted in the laboratory with air, surface, and water samples seeded with known concentrations of the target organisms. Additional studies were conducted with bulk materials (HEPA filter pleats and particulate found on the filter screen) obtained from the ISS.
Recommended protocols for sampling macrofungi
Gregory M. Mueller; John Paul Schmit; Sabine M. Hubndorf Leif Ryvarden; Thomas E. O' Dell; D. Jean Lodge; Patrick R. Leacock; Milagro Mata; Loengrin Umania; Qiuxin (Florence) Wu; Daniel L. Czederpiltz
2004-01-01
This chapter discusses several issues regarding reommended protocols for sampling macrofungi: Opportunistic sampling of macrofungi, sampling conspicuous macrofungi using fixed-size, sampling small Ascomycetes using microplots, and sampling a fixed number of downed logs.
National Sample Assessment Protocols
ERIC Educational Resources Information Center
Ministerial Council on Education, Employment, Training and Youth Affairs (NJ1), 2012
2012-01-01
These protocols represent a working guide for planning and implementing national sample assessments in connection with the national Key Performance Measures (KPMs). The protocols are intended for agencies involved in planning or conducting national sample assessments and personnel responsible for administering associated tenders or contracts,…
Quantifying India's HFC emissions from whole-air samples collected on the UK-India Monsoon campaign
NASA Astrophysics Data System (ADS)
Say, Daniel; Ganesan, Anita; O'Doherty, Simon; Bauguitte, Stephane; Rigby, Matt; Lunt, Mark
2017-04-01
With a population exceeding 1 billion and a rapidly expanding economy, greenhouse gas (GHG) emissions from India are of global significance. As of 2010, India's anthropogenic GHG emissions accounted for 5.6% of the global total, with this share predicted to grow significantly in the coming decades. We focus here on hydrofluorocarbons (HFCs), a diverse range of potent GHGs, whose role as replacements for ozone-depleting CFCs and HCFCs in air-conditioning and refrigeration applications (among others) has led to rapid atmospheric accumulation. Recent efforts to reduce their consumption (and subsequent emission) culminated in an amendment to the Montreal Protocol; member states are now required to phase-down their use of HFCs, with the first cuts planned for 2019. Despite the potential climate implications, atmospheric measurements of HFCs in India, required for quantifying their emissions using top-down inverse methods, have not previously existed. Here we present the first Indian hydrofluorocarbon (HFC) observations, obtained during two months of low altitude (<2000 m) flights. Of the 176 whole air samples collected on board the UK's NERC-FAAM (Facility for Airborne Atmospheric Measurements) research aircraft, the majority were obtained above the Indo-Gangetic Plains of Northern India, where population density is greatest. Using a small subset of samples filled above the Arabian Sea, we derive compound specific baselines, to which the remaining samples are compared. Significant mole fraction enhancements are observed for all major HFCs, indicating the presence of regional emissions sources. Little enhancement is observed in the concentration of various HFC predecessors, including CFCs, suggesting India's success in phasing out the majority of ozone depleting substances. Using these atmospheric observations and the NAME (Numerical Atmospheric dispersion Modelling Environment) atmospheric transport model, we present the first regional HFC flux estimates for India.
Dejmek, Annika; Zendehrokh, Nooreldin; Tomaszewska, Malgorzata; Edsjö, Anders
2013-07-01
Personalized oncology requires molecular analysis of tumor cells. Several studies have demonstrated that cytological material is suitable for DNA analysis, but to the authors' knowledge there are no systematic studies comparing how the yield and quality of extracted DNA is affected by the various techniques used for the preparation of cytological material. DNA yield and quality were compared using cultured human lung cancer cells subjected to different preparation techniques used in routine cytology, including fixation, mounting medium, and staining. The results were compared with the outcome of epidermal growth factor receptor (EGFR) genotyping of 66 clinical cytological samples using the same DNA preparation protocol. All tested protocol combinations resulted in fragment lengths of at least 388 base pairs. The mounting agent EcoMount resulted in higher yields than traditional xylene-based medium. Spray and ethanol fixation resulted in both a higher yield and better DNA quality than air drying. In liquid-based cytology (LBC) methods, CytoLyt solution resulted in a 5-fold higher yield than CytoRich Red. Papanicolaou staining provided twice the yield of hematoxylin and eosin staining in both liquid-based preparations. Genotyping outcome and quality control values from the clinical EGFR genotyping demonstrated a sufficient amount and amplifiability of DNA in both spray-fixed and air-dried cytological samples. Reliable clinical genotyping can be performed using all tested methods. However, in the cell line experiments, spray- or ethanol-fixed, Papanicolaou-stained slides provided the best results in terms of yield and fragment length. In LBC, the DNA recovery efficiency of the preserving medium may differ considerably, which should be taken into consideration when introducing LBC. Cancer (Cancer Cytopathol) 2013;121:344-353. © 2013 American Cancer Society. © 2013 American Cancer Society.
A Draft Test Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Rummel, John D.; Race, Margaret S.; DeVinenzi, Donald L.; Schad, P. Jackson; Stabekis, Pericles D.; Viso, Michel; Acevedo, Sara E.
2002-01-01
This document presents the first complete draft of a protocol for detecting possible biohazards in Mars samples returned to Earth; it is the final product of the Mars Sample Handling Protocol Workshop Series, convened in 2000-2001 by NASA's Planetary Protection Officer. The goal of the five-workshop Series vas to develop a comprehensive protocol by which returned martian sample materials could be assessed for the presence of any biological hazard(s) while safeguarding the purity of the samples from possible terrestrial contamination The reference numbers for the proceedings from the five individual Workshops.
Sarigiannis, Dimosthenis A; Karakitsios, Spyros P; Gotti, Alberto; Liakos, Ioannis L; Katsoyiannis, Athanasios
2011-05-01
This paper summarizes recent data on the occurrence of major organic compounds (benzene, toluene, xylenes, styrene, acetaldehyde, formaldehyde, naphthalene, limonene, α-pinene and ammonia, classified by the European Commission's INDEX strategy report as the priority pollutants to be regulated) and evaluates accordingly cancer and non-cancer risks posed by indoor exposure in dwellings and public buildings in European Union (EU) countries. The review process indicated that significant differences in indoor air quality exist within and among the countries where data were available, indicating corresponding differences in sources and emission strength of airborne chemicals, identified or not. Conservative exposure limits were not exceeded for non-carcinogenic effects, except for formaldehyde; for carcinogenic agents the estimated risks were up to three orders of magnitude higher than the one (10(-6)) proposed as acceptable by risk management bodies. However, the risk assessment evaluation process faces crucial difficulties, either due to the relative paucity of indoor air quality measurements in many EU countries, or by the lack of sampling consistency in the already existing studies, indicating the need for additional measurements of indoor air quality following a harmonized sampling and analytical protocol. Additionally, uncertainties embodied in the cancer potency factors and exposure limit values impose further difficulties in substance prioritization and risk management. Copyright © 2011 Elsevier Ltd. All rights reserved.
Fractography evolution in accelerated aging of UHMWPE after gamma irradiation in air.
Medel, F; Gómez-Barrena, E; García-Alvarez, F; Ríos, R; Gracia-Villa, L; Puértolas, J A
2004-01-01
We studied the fracture surface evolution of ultra high molecular weight polyethylene (UHMWPE) specimens, manufactured from GUR 1050 compression moulded sheets, after gamma sterilisation in air followed by different aging times after thermal treatment at 120 degrees C. Degradation profiles were obtained by FTIR and DSC measurements after 0, 7, 14, 24 and 36h aging. We observed by SEM the morphology patterns at these aging times, in surface fractographies after uniaxial tensile test of standardised samples. The results pointed out clear differences between short and long aging times. At shorter times, 7h, the behaviour was similar to non-degraded UHMWPE, exhibiting ductile behaviour. At longer times, 24-36h, this thermal protocol provided a highly degraded zone in the subsurface, similar to the white band found after gamma irradiation in air followed by natural aging, although closer to the surface, at 150-200mum. The microstructure of this oxidation zone, similarly found in gamma irradiated samples shelf-aged for 6-7 years, although with different distribution of microvoids, was formed by fibrils, associated with embrittlement of the oxidised UHMWPE. In addition, the evolution of the oxidation index, the enthalpy content, the mechanical parameters, and the depth of the oxidation front deduced from the fractographies versus aging time showed that a changing behaviour in the degradation rate appeared at intermediate aging times.
49 CFR Appendix H to Part 229 - Static Noise Test Protocols-In-Cab Static
Code of Federal Regulations, 2014 CFR
2014-10-01
... normal operating temperature. (5) The heating, ventilation and air conditioning (HVAC) system or a dedicated heating or air conditioner system must be operating on high, and the vents must be open and...
49 CFR Appendix H to Part 229 - Static Noise Test Protocols-In-Cab Static
Code of Federal Regulations, 2013 CFR
2013-10-01
... normal operating temperature. (5) The heating, ventilation and air conditioning (HVAC) system or a dedicated heating or air conditioner system must be operating on high, and the vents must be open and...
49 CFR Appendix H to Part 229 - Static Noise Test Protocols-In-Cab Static
Code of Federal Regulations, 2012 CFR
2012-10-01
... normal operating temperature. (5) The heating, ventilation and air conditioning (HVAC) system or a dedicated heating or air conditioner system must be operating on high, and the vents must be open and...
49 CFR Appendix H to Part 229 - Static Noise Test Protocols-In-Cab Static
Code of Federal Regulations, 2011 CFR
2011-10-01
... normal operating temperature. (5) The heating, ventilation and air conditioning (HVAC) system or a dedicated heating or air conditioner system must be operating on high, and the vents must be open and...
Filosso, P L; Ruffini, E; Solidoro, P; Molinatti, M; Bruna, M C; Oliaro, A
2010-06-01
Prolonged air leaks remain one of the most important complication after pulmonary resection. The aim of this study was to test a new fast-track chest tube removal protocol using a new drainage system, which digitally records postoperative air leaks, compared to the traditional one, with subjective visual air leak assessment. Patients with moderate COPD undergoing lobectomy for primary lung cancer at the Department of Thoracic Surgery of the University of Torino were randomised in two groups with different chest drainage systems and different removal protocols: in Group A the drainage was removed after digitally recordered measurement of air leaks; in Group B the tube was removed according to the air leaks visualization by bubbling in the water column. The following variables were evaluated: first and second drainage removal day; overall hospital length of stay; overall hospitalization costs. First and second drainages were removed sooner in those patients with the digital drainage system. An earlier drainage removal is associated with significative reduction in hospital length of stay and overall hospitalization costs. The digital and continuous air leak measurement reduces the hospital length of stay by a more accurate and reproductive air leaks measurement. Further studies are mandatory to corroborate our preliminary results.
2007-03-01
provides a means for anyone who has access to an Internet connection to collect or disseminate information on a global scale at a very low cost. The......AIR UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base, Ohio APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED
Connor, Kip M; Krah, Nathan M; Dennison, Roberta J; Aderman, Christopher M; Chen, Jing; Guerin, Karen I; Sapieha, Przemyslaw; Stahl, Andreas; Willett, Keirnan L; Smith, Lois E H
2013-01-01
The mouse model of oxygen-induced retinopathy (OIR) has been widely used in studies related to retinopathy of prematurity, proliferative diabetic retinopathy and in studies evaluating the efficacy of antiangiogenic compounds. In this model, 7-d-old (P7) mouse pups with nursing mothers are subjected to hyperoxia (75% oxygen) for 5 d, which inhibits retinal vessel growth and causes significant vessel loss. on P12, mice are returned to room air and the hypoxic avascular retina triggers both normal vessel regrowth and retinal neovascularization (NV), which is maximal at P17. neovascularization spontaneously regresses between P17 and P25. although the OIR model has been the cornerstone of studies investigating proliferative retinopathies, there is currently no harmonized protocol to assess aspects of angiogenesis and treatment outcome. In this protocol we describe standards for mouse size, sample size, retinal preparation, quantification of vascular loss, vascular regrowth, NV and neovascular regression. PMID:19816419
NASA Astrophysics Data System (ADS)
Hu, Lei; Montzka, Stephen A.; Lehman, Scott J.; Godwin, David S.; Miller, Benjamin R.; Andrews, Arlyn E.; Thoning, Kirk; Miller, John B.; Sweeney, Colm; Siso, Caroline; Elkins, James W.; Hall, Bradley D.; Mondeel, Debra J.; Nance, David; Nehrkorn, Thomas; Mountain, Marikate; Fischer, Marc L.; Biraud, Sébastien C.; Chen, Huilin; Tans, Pieter P.
2017-08-01
Ozone depleting substances (ODSs) controlled by the Montreal Protocol are potent greenhouse gases (GHGs), as are their substitutes, the hydrofluorocarbons (HFCs). Here we provide for the first time a comprehensive estimate of U.S. emissions of ODSs and HFCs based on precise measurements in discrete air samples from across North America and in the remote atmosphere. Derived emissions show spatial and seasonal variations qualitatively consistent with known uses and largely confirm U.S. Environmental Protection Agency (EPA) national emissions inventories for most gases. The measurement-based results further indicate a substantial decline of ODS emissions from 2008 to 2014, equivalent to 50% of the CO2-equivalent decline in combined emissions of CO2 and all other long-lived GHGs inventoried by the EPA for the same period. Total estimated CO2-equivalent emissions of HFCs were comparable to the sum of ODS emissions in 2014, but can be expected to decline in the future in response to recent policy measures.
Jary, Hannah; Mallewa, Jane; Nyirenda, Mulinda; Faragher, Brian; Heyderman, Robert; Peterson, Ingrid; Gordon, Stephen; Mortimer, Kevin
2015-08-20
Pneumonia is the 2nd leading cause of years of life lost worldwide and is a common cause of adult admissions to hospital in sub-Saharan Africa. Risk factors for adult pneumonia are well characterised in developed countries, but are less well described in sub-Saharan Africa where HIV is a major contributing factor. Exposure to indoor and outdoor air pollution is high, and tobacco smoking prevalence is increasing in sub-Saharan Africa, yet the contribution of these factors to the burden of chronic respiratory diseases in sub-Saharan Africa remains poorly understood. Furthermore, the extent to which the presence of chronic respiratory diseases and exposure to air pollution contribute to the burden of pneumonia is not known. The Acute Infection of the Respiratory Tract Study (The AIR Study) is a case-control study to identify preventable risk factors for adult pneumonia in the city of Blantyre, Malawi. Cases will be adults admitted with pneumonia, recruited from Queen Elizabeth Central Hospital, the largest teaching hospital in Malawi. Controls will be adults without pneumonia, recruited from the community. The AIR Study will recruit subjects and analyse data within strata defined by positive and negative HIV infection status. All participants will undergo thorough assessment for a range of potential preventable risk factors, with an emphasis on exposure to air pollution and the presence of chronic respiratory diseases. This will include collection of questionnaire data, clinical samples (blood, urine, sputum and breath samples), lung function data and air pollution monitoring in their home. Multivariate analysis will be used to identify the important risk factors contributing to the pneumonia burden in this setting. Identification of preventable risk factors will justify research into the effectiveness of targeted interventions to address this burden in the future. The AIR Study is the first study of radiologically confirmed pneumonia in which air pollution exposure measurements have been undertaken in this setting, and will contribute important new information about exposure to air pollution in urban SSA. Through identification of preventable risk factors, the AIR Study aims to facilitate future research and implementation of targeted interventions to reduce the high burden of pneumonia in SSA.
Optical Trap Loading of Dielectric Microparticles In Air.
Park, Haesung; LeBrun, Thomas W
2017-02-05
We demonstrate a method to trap a selected dielectric microparticle in air using radiation pressure from a single-beam gradient optical trap. Randomly scattered dielectric microparticles adhered to a glass substrate are momentarily detached using ultrasonic vibrations generated by a piezoelectric transducer (PZT). Then, the optical beam focused on a selected particle lifts it up to the optical trap while the vibrationally excited microparticles fall back to the substrate. A particle may be trapped at the nominal focus of the trapping beam or at a position above the focus (referred to here as the levitation position) where gravity provides the restoring force. After the measurement, the trapped particle can be placed at a desired position on the substrate in a controlled manner. In this protocol, an experimental procedure for selective optical trap loading in air is outlined. First, the experimental setup is briefly introduced. Second, the design and fabrication of a PZT holder and a sample enclosure are illustrated in detail. The optical trap loading of a selected microparticle is then demonstrated with step-by-step instructions including sample preparation, launching into the trap, and use of electrostatic force to excite particle motion in the trap and measure charge. Finally, we present recorded particle trajectories of Brownian and ballistic motions of a trapped microparticle in air. These trajectories can be used to measure stiffness or to verify optical alignment through time domain and frequency domain analysis. Selective trap loading enables optical tweezers to track a particle and its changes over repeated trap loadings in a reversible manner, thereby enabling studies of particle-surface interaction.
NASA Astrophysics Data System (ADS)
Kuzmiakova, Adele; Dillner, Ann M.; Takahama, Satoshi
2016-06-01
A growing body of research on statistical applications for characterization of atmospheric aerosol Fourier transform infrared (FT-IR) samples collected on polytetrafluoroethylene (PTFE) filters (e.g., Russell et al., 2011; Ruthenburg et al., 2014) and a rising interest in analyzing FT-IR samples collected by air quality monitoring networks call for an automated PTFE baseline correction solution. The existing polynomial technique (Takahama et al., 2013) is not scalable to a project with a large number of aerosol samples because it contains many parameters and requires expert intervention. Therefore, the question of how to develop an automated method for baseline correcting hundreds to thousands of ambient aerosol spectra given the variability in both environmental mixture composition and PTFE baselines remains. This study approaches the question by detailing the statistical protocol, which allows for the precise definition of analyte and background subregions, applies nonparametric smoothing splines to reproduce sample-specific PTFE variations, and integrates performance metrics from atmospheric aerosol and blank samples alike in the smoothing parameter selection. Referencing 794 atmospheric aerosol samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites collected during 2011, we start by identifying key FT-IR signal characteristics, such as non-negative absorbance or analyte segment transformation, to capture sample-specific transitions between background and analyte. While referring to qualitative properties of PTFE background, the goal of smoothing splines interpolation is to learn the baseline structure in the background region to predict the baseline structure in the analyte region. We then validate the model by comparing smoothing splines baseline-corrected spectra with uncorrected and polynomial baseline (PB)-corrected equivalents via three statistical applications: (1) clustering analysis, (2) functional group quantification, and (3) thermal optical reflectance (TOR) organic carbon (OC) and elemental carbon (EC) predictions. The discrepancy rate for a four-cluster solution is 10 %. For all functional groups but carboxylic COH the discrepancy is ≤ 10 %. Performance metrics obtained from TOR OC and EC predictions (R2 ≥ 0.94 %, bias ≤ 0.01 µg m-3, and error ≤ 0.04 µg m-3) are on a par with those obtained from uncorrected and PB-corrected spectra. The proposed protocol leads to visually and analytically similar estimates as those generated by the polynomial method. More importantly, the automated solution allows us and future users to evaluate its analytical reproducibility while minimizing reducible user bias. We anticipate the protocol will enable FT-IR researchers and data analysts to quickly and reliably analyze a large amount of data and connect them to a variety of available statistical learning methods to be applied to analyte absorbances isolated in atmospheric aerosol samples.
A multigear protocol for sampling crayfish assemblages in Gulf of Mexico coastal streams
William R. Budnick; William E. Kelso; Susan B. Adams; Michael D. Kaller
2018-01-01
Identifying an effective protocol for sampling crayfish in streams that vary in habitat and physical/chemical characteristics has proven problematic. We evaluated an active, combined-gear (backpack electrofishing and dipnetting) sampling protocol in 20 Coastal Plain streams in Louisiana. Using generalized linear models and rarefaction curves, we evaluated environmental...
NASA Astrophysics Data System (ADS)
Juszczak, R.; Pihlatie, M.; Christiansen, J. R.; Giebels, M.; Schreiber, P.; Aaltonen, H.; Korhonen, J.; Rasilo, T.; Chojnicki, B. H.; Urbaniak, M.
2009-04-01
Closed static chambers are often used for greenhouse gas flux measurements from soils. The type of chamber, chamber handling and sampling protocol can influence the measurements. In most cases the calculated fluxes are suspected to be underestimated mainly because of reduction of gas diffusion from the soil to chamber headspace due to changed trace gas concentration gradient. Thus, fans are often applied to obtain better mixing of the air inside the chamber headspace and in turn reduce the negative effect of decreased concentration gradient. The open question is, however, to which extent the fluxes are changed by fans and whether they still remain underestimated or may even be overestimated? On the other hand, different sampling protocols are used assuming that they do not affect the flux measurements. To test different types of static chambers and different sampling procedures applied for measurement of greenhouse gas (CH4 and N2O) fluxes a chamber calibration campaign was organized at Hyytiälä Forestry Field Station in Southern Finland during August-October 2008. The main aim of the campaign was to quantitatively assess the uncertaintities and errors related to static chamber measurements. During this campaign static chambers were tested for 5 different CH4 and N2O flux levels with 3 different soil conditions (moisture and porosity) in a calibration tank described by Pumpanen et al. (2004). Among the different experiments, several special tests were carried out with the closed static chambers. Here, results of two special tests are presented to document whether 1) the air mixing inside the chamber headspace, 2) different sampling procedures influence the CH4 fluxes, and 3) how different calculation methods lead to varying results. Two static chambers of different volumes (65.5 and 195 liters) but with the same circular shape and surface area were connected to a LOS GATOS fats methane analyzer. The CH4 concentration inside the chamber headspace was monitored continuously with 1Hz frequency. Additionally, two different manual samplings procedures were tested and gas samples from chamber headspace were taken for gas chromatograph (GC) and analysed in two different laboratories. Gas concentrations in the calibration tank were monitored with a GC and an automatic gas analyzer (INNOVA). The preliminary results showed that air mixing inside the chamber headspace, the way of chamber handling and sampling procedures could have pronounced influence on the trace gas concentration detection inside a chamber, and as a consequence the calculated chamber fluxes. The moment of chamber enclosure can lead to a rapid increase in CH4 concentration due to a pressure effect in the chambers without a vent tube. Thus, it is essential to critically estimate the time of the first sampling so that it is early enough after chamber enclosure, but not disturbed by the initial chamber handling. It was also observed that manual sampling of gas can change the CH4 concentration in the chamber headspace. When mixing the chamber headspace air by a syringe, the subsequent gas sampling in the syringe may affect the diffusion of gas between the soil and the chamber headspace, and hence affect the calculated fluxes. It was observed that mixing the chamber headspace with a fan instead of syringes, reduced this effect during the chamber enclosure. Overall, fluxes measured with chamber equipped with a fan always gave higher fluxes (up to 40%) as compared to fluxes measured from chambers without a fan. Results of our experiment lead to the assumption that these differences were generally larger the higher the chamber was, the less porous the soil was, and the higher the fluxes were. We conclude from our experiment that static chambers used for greenhouse gas flux measurements should be equipped with at least one fan and a vent tube to increase mixing and reduce pressure propagation in the chamber-soil system, and that special attention should be paid to the handling of the chamber and to the timing of the gas sampling. References: Pumpanen, J., Kolari, P., Ilvesniemi, H., Minkkinen, K., Vesala, T., Niinistö, S., Lohila, A., Larmola, T., Morero, M., Pihlatie, M., Janssens, I., Curiel Yuste, J., Grünzweig, J. M., Reth, S., Subke, J.-A., Savage, K., Kutsch, W., Østreng, G., Ziegler, W., Anthoni, P., Lindroth, A. & Hari, P. 2004. Comparison of different chamber techniques for measuring soil CO2 efflux. Agricultural and Forest Meteorology 123, 159-176.
Schoj, Verónica; Sebrié, Ernesto M; Pizarro, María Elizabeth; Hyland, Andrew; Travers, Mark J
2015-01-01
Objective To evaluate indoor air pollution in hospitality venues in Argentina. Material and Methods PM2.5 levels were measured in a convenience sample of venues in 15 cities with different legislative contexts following a protocol developed by Roswell Park Cancer Institute. Results 554 samples were collected. Across all 5 smokefree cities the mean PM2.5 level was lower during daytime vs. evening hours, 24 vs. 98 PM2.5 respectively (p=.012). In the three cities evaluated before and after legislation, PM2.5 levels decreased dramatically (p<0.001 each). Overall, PM2.5 levels were 5 times higher in cities with no legislation vs. smokefree cities (p<0.001). In cities with designated smoking areas, PM2.5 levels were not statistically different between smoking and non-smoking areas (p=0.272). Non-smoking areas had significantly higher PM2.5 levels compared to 100% smokefree venues in the same city (twofold higher) (p=0.017). Conclusions Most of the participating cities in this study had significantly lower PM2.5 levels after the implementation of 100% smokefree legislation. Hence, it represents a useful tool to promote 100% smokefree policies in Argentina. PMID:21243186
NASA Astrophysics Data System (ADS)
Rivera-Denizard, O.; Betancourt, C.; Armstrong, R. A.; Detres, Y.
2003-12-01
A wide variety of microorganisms are dispersed into the Caribbean region due to the input of Saharan dust aerosols during the summer months. These microorganisms can cause diseases in plants and animals, and might be responsible for an increase incidence of asthma and respiratory diseases in this region. A PM 2.5 air sampling station was installed in Castle Bruce, Dominica from March through July of 2002. Fourteen filters were obtained by running the air sampler continuously for 24 hour periods. The samples were collected in sterile Teflon filters (47 mm in diameter, 0.2 um pore size), inoculated in Malt Extract Agar (MEA) with lactic acid and incubated at 29° C. Colonies were counted, isolated and cultured on separate Petri dishes. Fungal classification to the genus level used macroscopic features and microscopic evaluation. The Nomarski light microscopy technique was used for identification of reproductive structures. A total of 105 colonies were isolated. Six genera including Aspergillus, Penicillium, Cladosporium, Fusarium, Curvularia,and Nigrospora were identified. The protocol for the molecular characterization to species level is presented as the second part of this work.
The development of radioactive sample surrogates for training and exercises
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martha Finck; Bevin Brush; Dick Jansen
2012-03-01
The development of radioactive sample surrogates for training and exercises Source term information is required for to reconstruct a device used in a dispersed radiological dispersal device. Simulating a radioactive environment to train and exercise sampling and sample characterization methods with suitable sample materials is a continued challenge. The Idaho National Laboratory has developed and permitted a Radioactive Response Training Range (RRTR), an 800 acre test range that is approved for open air dispersal of activated KBr, for training first responders in the entry and exit from radioactively contaminated areas, and testing protocols for environmental sampling and field characterization. Membersmore » from the Department of Defense, Law Enforcement, and the Department of Energy participated in the first contamination exercise that was conducted at the RRTR in the July 2011. The range was contaminated using a short lived radioactive Br-82 isotope (activated KBr). Soil samples contaminated with KBr (dispersed as a solution) and glass particles containing activated potassium bromide that emulated dispersed radioactive materials (such as ceramic-based sealed source materials) were collected to assess environmental sampling and characterization techniques. This presentation summarizes the performance of a radioactive materials surrogate for use as a training aide for nuclear forensics.« less
Low Cost Extraction and Isothermal Amplification of DNA for Infectious Diarrhea Diagnosis
Huang, Shichu; Do, Jaephil; Mahalanabis, Madhumita; Fan, Andy; Zhao, Lei; Jepeal, Lisa; Singh, Satish K.; Klapperich, Catherine M.
2013-01-01
In order to counter the common perception that molecular diagnostics are too complicated to work in low resource settings, we have performed a difficult sample preparation and DNA amplification protocol using instrumentation designed to be operated without wall or battery power. In this work we have combined a nearly electricity-free nucleic acid extraction process with an electricity-free isothermal amplification assay to detect the presence of Clostridium difficile (C. difficile) DNA in the stool of infected patients. We used helicase-dependent isothermal amplification (HDA) to amplify the DNA in a low-cost, thermoplastic reaction chip heated with a pair of commercially available toe warmers, while using a simple Styrofoam insulator. DNA was extracted from known positive and negative stool samples. The DNA extraction protocol utilized an air pressure driven solid phase extraction device run using a standard bicycle pump. The simple heater setup required no electricity or battery and was capable of maintaining the temperature at 65°C±2°C for 55 min, suitable for repeatable HDA amplification. Experiments were performed to explore the adaptability of the system for use in a range of ambient conditions. When compared to a traditional centrifuge extraction protocol and a laboratory thermocycler, this disposable, no power platform achieved approximately the same lower limit of detection (1.25×10−2 pg of C. difficile DNA) while requiring much less raw material and a fraction of the lab infrastructure and cost. This proof of concept study could greatly impact the accessibility of molecular assays for applications in global health. PMID:23555883
TESTING INDOOR AIR PRODUCTS: ONE APPROACH TO DEVELOPING WIDELY ACCEPTED PROTOCOLS
The paper describes an approach to developing widely acce ted products for testing indoor air products. [NOTE: Research Triangle Institute (RTI) is a partner in the U.S. Environmental Protection Agency's (EPA's) Environmental Technology Verification (ETV) Program with responsibil...
Srivastava, Abneesh; Hodges, Joseph T
2018-06-05
Isotope dilution-cold-vapor-inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has become the primary standard for measurement of gaseous elemental mercury (GEM) mass concentration. However, quantitative mass spectrometry is challenging for several reasons including (1) the need for isotopic spiking with a standard reference material, (2) the requirement for bias-free passive sampling protocols, (3) the need for stable mass spectrometry interface design, and (4) the time and cost involved for gas sampling, sample processing, and instrument calibration. Here, we introduce a high-resolution laser absorption spectroscopy method that eliminates the need for sample-specific calibration standards or detailed analysis of sample treatment losses. This technique involves a tunable, single-frequency laser absorption spectrometer that measures isotopically resolved spectra of elemental mercury (Hg) spectra of 6 1 S 0 ← 6 3 P 1 intercombination transition near λ = 253.7 nm. Measured spectra are accurately modeled from first-principles using the Beer-Lambert law and Voigt line profiles combined with literature values for line positions, line shape parameters, and the spontaneous emission Einstein coefficient to obtain GEM mass concentration values. We present application of this method for the measurement of the equilibrium concentration of mercury vapor near room temperature. Three closed systems are considered: two-phase mixtures of liquid Hg and its vapor and binary two-phase mixtures of Hg-air and Hg-N 2 near atmospheric pressure. Within the experimental relative standard uncertainty, 0.9-1.5% congruent values of the equilibrium Hg vapor concentration are obtained for the Hg-only, Hg-air, Hg-N 2 systems, in confirmation with thermodynamic predictions. We also discuss detection limits and the potential of the present technique to serve as an absolute primary standard for measurements of gas-phase mercury concentration and isotopic composition.
A distance limited method for sampling downed coarse woody debris
Jeffrey H. Gove; Mark J. Ducey; Harry T. Valentine; Michael S. Williams
2012-01-01
A new sampling method for down coarse woody debris is proposed based on limiting the perpendicular distance from individual pieces to a randomly chosen sample point. Two approaches are presented that allow different protocols to be used to determine field measurements; estimators for each protocol are also developed. Both protocols are compared via simulation against...
Silanated Surface Treatment: Effects on the Bond Strength to Lithium Disilicate Glass-Ceramic.
Baratto, Samantha Schaffer Pugsley; Spina, Denis Roberto Falcão; Gonzaga, Carla Castiglia; Cunha, Leonardo Fernandes da; Furuse, Adilson Yoshio; Baratto Filho, Flares; Correr, Gisele Maria
2015-10-01
The aim of this study was to evaluate the effect of silanization protocols on the bond strength of two resin cements to a lithium disilicate glass-ceramic. Thirty-two ceramic discs were assigned to 2 groups (n=16): G1 - dual-cured resin cement and G2 - light-cured resin cement. Four subgroups were evaluated according to the used silanization protocol. The glass-ceramic was etched with 10% hydrofluoric acid for 20 s and silane was applied for 1 min, as follows: CTL - according to the manufacturer's instructions; HA - dried with hot air; NWA - washed and dried with water and air at room temperature; HWA - washed and dried with hot water and hot air. Thereafter, adhesive was applied and light-cured for 20 s. Silicon molds were used to prepare resin cement cylinders (1x1 mm) on the ceramic surface. The specimens were stored in deionized water at 37 °C for 48 h and subjected to a micro-shear test. The data were submitted to statistical analysis (?#61537;=0.05). Group G1 showed higher bond strengths than G2, except for the CTL and NWA subgroups. Differences as function of the silanization protocol were only observed in G1: HWA (25.13±6.83)≥HA (22.95±7.78)≥CTL(17.44±7.24) ≥NWA(14.63±8.76). For G2 there was no difference among the subgroups. In conclusion, the silanization protocol affected the resin cement/ceramic bond strengths, depending on the material. Washing/drying with hot water and/or hot air increased only the bond strength of the dual-cured resin cement.
Fell, Shari; Bröckl, Stephanie; Büttner, Mathias; Rettinger, Anna; Zimmermann, Pia; Straubinger, Reinhard K
2016-09-15
Bovine tuberculosis (bTB), which is caused by Mycobacterium bovis and M. caprae, is a notifiable animal disease in Germany. Diagnostic procedure is based on a prescribed protocol that is published in the framework of German bTB legislation. In this protocol small sample volumes are used for DNA extraction followed by real-time PCR analyses. As mycobacteria tend to concentrate in granuloma and the infected tissue in early stages of infection does not necessarily show any visible lesions, it is likely that DNA extraction from only small tissue samples (20-40 mg) of a randomly chosen spot from the organ and following PCR testing may result in false negative results. In this study two DNA extraction methods were developed to process larger sample volumes to increase the detection sensitivity of mycobacterial DNA in animal tissue. The first extraction method is based on magnetic capture, in which specific capture oligonucleotides were utilized. These nucleotides are linked to magnetic particles and capture Mycobacterium-tuberculosis-complex (MTC) DNA released from 10 to 15 g of tissue material. In a second approach remaining sediments from the magnetic capture protocol were further processed with a less complex extraction protocol that can be used in daily routine diagnostics. A total number of 100 tissue samples from 34 cattle (n = 74) and 18 red deer (n = 26) were analyzed with the developed protocols and results were compared to the prescribed protocol. All three extraction methods yield reliable results by the real-time PCR analysis. The use of larger sample volume led to a sensitivity increase of DNA detection which was shown by the decrease of Ct-values. Furthermore five samples which were tested negative or questionable by the official extraction protocol were detected positive by real time PCR when the alternative extraction methods were used. By calculating the kappa index, the three extraction protocols resulted in a moderate (0.52; protocol 1 vs 3) to almost perfect agreement (1.00; red deer sample testing with all protocols). Both new methods yielded increased detection rates for MTC DNA detection in large sample volumes and consequently improve the official diagnostic protocol.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-28
...EPA is finalizing rule revisions that modify existing requirements for sources affected by the federally administered emission trading programs including the NOX Budget Trading Program, the Acid Rain Program, and the Clean Air Interstate Rule. EPA is amending its Protocol Gas Verification Program (PGVP) and the minimum competency requirements for air emission testing (formerly air emission testing body requirements) to improve the accuracy of emissions data. EPA is also amending other sections of the Acid Rain Program continuous emission monitoring system regulations by adding and clarifying certain recordkeeping and reporting requirements, removing the provisions pertaining to mercury monitoring and reporting, removing certain requirements associated with a class-approved alternative monitoring system, disallowing the use of a particular quality assurance option in EPA Reference Method 7E, adding two incorporation by references that were inadvertently left out of the January 24, 2008 final rule, adding two new definitions, revising certain compliance dates, and clarifying the language and applicability of certain provisions.
Fourie, O L
2004-03-01
This note investigates the calibration of a Scanditronix-Wellhöfer type FC65-G ionisation chamber to be used in clinical photon dosimetry. The current Adaptation by the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) of the IAEA TRS 277 dosimetry protocol makes no provision for this type of chamber. The absorbed dose to air calibration coefficient ND was therefore calculated from the air kerma calibration coefficient NK using the formalism of the IAEA TRS 277 protocol and it is shown that the value of the correction factor kmkatt for the FC65-G chamber is identical to that of the NE 2571 chamber. ND was also determined experimentally from a cross calibration against an NE 2571 dosimetry. It was found that there is a good correspondence between the calculated and measured values. To establish to what extent the ACPSEM Adaptation can be used for the FC65-G chamber, values for the ratio of stopping powers in water and air (Sw,air)Q and the perturbation correction factor pQ were calculated using the TRS 277 protocol. From these results it is shown that over the range of beam qualities TPR20,10 = 0.59 to TPR20,10 = 0.78 the Adaptation can be used for the FC65-G chamber.
Air leak after lung resection: pathophysiology and patients' implications.
Pompili, Cecilia; Miserocchi, Giuseppe
2016-02-01
Protocols for the management of air leaks are critical aspects in the postoperative course of patients following lung resections. Many investigations in the last decade are focusing on the chest tube modalities or preventative measures, however, little is known about the pathophysiology of air leak and the patient perception of this common complication. This review concentrates on understanding the reasons why a pulmonary parenchyma may start to leak or an air leak may be longer than others. Experimental works support the notion that lung overdistension may favor air leak. These studies may represent the basis of future investigations. Furthermore, the standardization of nomenclature in the field of pleural space management and the creation of novel air leak scoring systems have contributed to improve the knowledge among thoracic surgeons and facilitate the organization of trials on this matter. We tried to summarize available evidences about the patient perception of a prolonged air leak and about what would be useful for them in order to prevent worsening of their quality of life. Future investigations are warranted to better understand the pathophysiologic mechanisms responsible of prolonged air leak in order to define tailored treatments and protocols. Improving the care at home with web-based telemonitoring or real time connected chest drainage may in a future improve the quality of life of the patients experience this complication and also enhance hospital finances.
Air leak after lung resection: pathophysiology and patients’ implications
Miserocchi, Giuseppe
2016-01-01
Protocols for the management of air leaks are critical aspects in the postoperative course of patients following lung resections. Many investigations in the last decade are focusing on the chest tube modalities or preventative measures, however, little is known about the pathophysiology of air leak and the patient perception of this common complication. This review concentrates on understanding the reasons why a pulmonary parenchyma may start to leak or an air leak may be longer than others. Experimental works support the notion that lung overdistension may favor air leak. These studies may represent the basis of future investigations. Furthermore, the standardization of nomenclature in the field of pleural space management and the creation of novel air leak scoring systems have contributed to improve the knowledge among thoracic surgeons and facilitate the organization of trials on this matter. We tried to summarize available evidences about the patient perception of a prolonged air leak and about what would be useful for them in order to prevent worsening of their quality of life. Future investigations are warranted to better understand the pathophysiologic mechanisms responsible of prolonged air leak in order to define tailored treatments and protocols. Improving the care at home with web-based telemonitoring or real time connected chest drainage may in a future improve the quality of life of the patients experience this complication and also enhance hospital finances. PMID:26941970
Mapping the human atria with optical coherence tomography
NASA Astrophysics Data System (ADS)
Lye, Theresa H.; Gan, Yu; Hendon, Christine P.
2017-02-01
Atrial structure plays an important role in the mechanisms of atrial disease. However, detailed imaging of human atria remains limited due to many imaging modalities lacking sufficient resolution. We propose the use of optical coherence tomography (OCT), which has micrometer resolution and millimeter-scale imaging depth well-suited for the atria, combined with image stitching algorithms, to develop large, detailed atria image maps. Human atria samples (n = 7) were obtained under approved protocols from the National Disease Research Interchange (NDRI). One right atria sample was imaged using an ultrahigh-resolution spectral domain OCT system, with 5.52 and 2.72 μm lateral and axial resolution in air, respectively, and 1.78 mm imaging depth. Six left atria and five pulmonary vein samples were imaged using the spectral domain OCT system, Telesto I (Thorlabs GmbH, Germany) with 15 and 6.5 μm lateral and axial resolution in air, respectively, and 2.51 mm imaging depth. Overlapping image volumes were obtained from areas of the human left and right atria and the pulmonary veins. Regions of collagen, adipose, and myocardium could be identified within the OCT images. Image stitching was applied to generate fields of view with side dimensions up to about 3 cm. This study established steps towards mapping large regions of the human atria and pulmonary veins in high resolution using OCT.
Development of Standardized Material Testing Protocols for Prosthetic Liners
Cagle, John C.; Reinhall, Per G.; Hafner, Brian J.; Sanders, Joan E.
2017-01-01
A set of protocols was created to characterize prosthetic liners across six clinically relevant material properties. Properties included compressive elasticity, shear elasticity, tensile elasticity, volumetric elasticity, coefficient of friction (CoF), and thermal conductivity. Eighteen prosthetic liners representing the diverse range of commercial products were evaluated to create test procedures that maximized repeatability, minimized error, and provided clinically meaningful results. Shear and tensile elasticity test designs were augmented with finite element analysis (FEA) to optimize specimen geometries. Results showed that because of the wide range of available liner products, the compressive elasticity and tensile elasticity tests required two test maxima; samples were tested until they met either a strain-based or a stress-based maximum, whichever was reached first. The shear and tensile elasticity tests required that no cyclic conditioning be conducted because of limited endurance of the mounting adhesive with some liner materials. The coefficient of friction test was based on dynamic coefficient of friction, as it proved to be a more reliable measurement than static coefficient of friction. The volumetric elasticity test required that air be released beneath samples in the test chamber before testing. The thermal conductivity test best reflected the clinical environment when thermal grease was omitted and when liner samples were placed under pressure consistent with load bearing conditions. The developed procedures provide a standardized approach for evaluating liner products in the prosthetics industry. Test results can be used to improve clinical selection of liners for individual patients and guide development of new liner products. PMID:28233885
Effects of gasoline engine emissions on preexisting allergic airway responses in mice.
Day, Kimberly C; Reed, Matthew D; McDonald, Jacob D; Seilkop, Steven K; Barrett, Edward G
2008-10-01
Gasoline-powered vehicle emissions contribute significantly to ambient air pollution. We hypothesized that exposure to gasoline engine emissions (GEE) may exacerbate preexisting allergic airway responses. Male BALB/c mice were sensitized by injection with ovalbumin (OVA) and then received a 10-min aerosolized OVA challenge. Parallel groups were sham-sensitized with saline. Mice were exposed 6 h/day to air (control, C) or GEE containing particulate matter (PM) at low (L), medium (M), or high (H) concentrations, or to the H level with PM removed by filtration (high-filtered, HF). Immediately after GEE exposure mice received another 10-min aerosol OVA challenge (pre-OVA protocol). In a second (post-OVA) protocol, mice were similarly sensitized but only challenged to OVA before air or GEE exposure. Measurements of airway hyperresponsiveness (AHR), bronchoalveolar lavage (BAL), and blood collection were performed approximately 24 h after the last exposure. In both protocols, M, H, and HF GEE exposure significantly decreased BAL neutrophils from nonsensitized mice but had no significant effect on BAL cells from OVA-sensitized mice. In the pre-OVA protocol, GEE exposure increased OVA-specific IgG(1) but had no effect on BAL interleukin (IL)-2, IL-4, IL-13, or interferon (IFN)-gamma in OVA-sensitized mice. Nonsensitized GEE-exposed mice had increased OVA-specific IgG(2a), IgE, and IL-2, but decreased total IgE. In the post-OVA protocol, GEE exposure reduced BAL IL-4, IL-5, and IFN-gamma in nonsensitized mice but had no effect on sensitized mice. These results suggest acute exposure to the gas-vapor phase of GEE suppressed inflammatory cells and cytokines from nonsensitized mice but did not substantially exacerbate allergic responses.
Correlation Between Iron and alpha and pi Glutathione-S-Transferase Levels in Humans
2012-09-01
assays were performed as described in the Biotrin High Sensitivity Alpha GST EIA kit protocol. First, serum samples were diluted 1:10 with wash solution...immunosorbent assays were performed as described in the Biotrin Pi GST EIA kit protocol. First, plasma samples were diluted 1:5 with sample diluent...immunosorbent assays were performed as described in the AssayMax Human Transferrin ELISA kit protocol. First, serum samples were diluted 1:2000 with MIX
Petersen, James C.; Justus, B.G.; Dodd, H.R.; Bowles, D.E.; Morrison, L.W.; Williams, M.H.; Rowell, G.A.
2008-01-01
Buffalo National River located in north-central Arkansas, and Ozark National Scenic Riverways, located in southeastern Missouri, are the two largest units of the National Park Service in the Ozark Plateaus physiographic province. The purpose of this report is to provide a protocol that will be used by the National Park Service to sample fish communities and collect related water-quality, habitat, and stream discharge data of Buffalo National River and Ozark National Scenic Riverways to meet inventory and long-term monitoring objectives. The protocol includes (1) a protocol narrative, (2) several standard operating procedures, and (3) supplemental information helpful for implementation of the protocol. The protocol narrative provides background information about the protocol such as the rationale of why a particular resource or resource issue was selected for monitoring, information concerning the resource or resource issue of interest, a description of how monitoring results will inform management decisions, and a discussion of the linkages between this and other monitoring projects. The standard operating procedures cover preparation, training, reach selection, water-quality sampling, fish community sampling, physical habitat collection, measuring stream discharge, equipment maintenance and storage, data management and analysis, reporting, and protocol revision procedures. Much of the information in the standard operating procedures was gathered from existing protocols of the U.S. Geological Survey National Water Quality Assessment program or other sources. Supplemental information that would be helpful for implementing the protocol is included. This information includes information on fish species known or suspected to occur in the parks, sample sites, sample design, fish species traits, index of biotic integrity metrics, sampling equipment, and field forms.
Partitioning and bioavailability of mercury in an experimentally acidified Wisconsin lake
Wiener, James G.; Fitzgerald, William F.; Watras, Carl J.; Rada, Ronald G.
1990-01-01
We studied the partitioning of mercury (Hg) among air, water, sediments and fish at Little Rock Lake, a clear water seepage lake in north-central Wisconsin. The lake was divided with a sea curtain into two basins, one acidified with sulfuric acid to pH 5.6 for two years and the other an untreated reference site (mean pH 6.1), to document the effects of acidification. Trace-metal-free protocols were used to measure Hg at the picomolar level in air and water. Total gaseous Hg in air samples averaged 2.0 ng/m3. Total Hg in unfiltered water samples collected in 1986 after the fall overturn averaged about 1 ng/L in the acidified and reference basins. Mercury in surficial sediments was strongly correlated with volatile matter content and ranged from 10 to about 170 ng/g (dry weight) in both basins. Total Hg concentrations in whole, calendar age-1 yellow perch (Perca flavescens), sampled after one year of residence in the lake, averaged 114 ng/g (fresh weight) in the reference basin and 135 ng/g in the acidified basin – a highly significant (p < 0.01) difference. The mean whole-body burden (quantity) of Hg in age-1 perch did not differ between basins after the first year, but was significantly greater in the treatment basin than in the reference basin after the second year of acidification. Differences between the two basins in the bioaccumulation of Hg were attributed to internal (within-lake) processes that influence the bioavailability of the metal. An initial Hg budget for the treatment basin of Little Rock Lake showed that atmospheric deposition and sedimentary remobilization of Hg are potentially important processes influencing its biogeochemical cycling and uptake by fish.
Tissue Sampling Guides for Porcine Biomedical Models.
Albl, Barbara; Haesner, Serena; Braun-Reichhart, Christina; Streckel, Elisabeth; Renner, Simone; Seeliger, Frank; Wolf, Eckhard; Wanke, Rüdiger; Blutke, Andreas
2016-04-01
This article provides guidelines for organ and tissue sampling adapted to porcine animal models in translational medical research. Detailed protocols for the determination of sampling locations and numbers as well as recommendations on the orientation, size, and trimming direction of samples from ∼50 different porcine organs and tissues are provided in the Supplementary Material. The proposed sampling protocols include the generation of samples suitable for subsequent qualitative and quantitative analyses, including cryohistology, paraffin, and plastic histology; immunohistochemistry;in situhybridization; electron microscopy; and quantitative stereology as well as molecular analyses of DNA, RNA, proteins, metabolites, and electrolytes. With regard to the planned extent of sampling efforts, time, and personnel expenses, and dependent upon the scheduled analyses, different protocols are provided. These protocols are adjusted for (I) routine screenings, as used in general toxicity studies or in analyses of gene expression patterns or histopathological organ alterations, (II) advanced analyses of single organs/tissues, and (III) large-scale sampling procedures to be applied in biobank projects. Providing a robust reference for studies of porcine models, the described protocols will ensure the efficiency of sampling, the systematic recovery of high-quality samples representing the entire organ or tissue as well as the intra-/interstudy comparability and reproducibility of results. © The Author(s) 2016.
Lead Sampling Protocols: Why So Many and What Do They Tell You?
Sampling protocols can be broadly categorized based on their intended purpose of 1) Pb regulatory compliance/corrosion control efficacy, 2) Pb plumbing source determination or Pb type identification, and 3) Pb exposure assessment. Choosing the appropriate protocol is crucial to p...
NHEXAS PHASE I MARYLAND STUDY--LIST OF AVAILABLE DOCUMENTS: PROTOCOLS AND SOPS
This document lists available protocols and SOPs for the NHEXAS Phase I Maryland study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis and general laboratory procedures, (3) Data Analysis Proced...
NASA Astrophysics Data System (ADS)
Lye, J. E.; Harty, P. D.; Butler, D. J.; Crosbie, J. C.; Livingstone, J.; Poole, C. M.; Ramanathan, G.; Wright, T.; Stevenson, A. W.
2016-06-01
The absolute dose delivered to a dynamically scanned sample in the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter anticipated to be established as a primary standard for synchrotron dosimetry. The calorimetry was compared to measurements using a free-air chamber (FAC), a PTW 31 014 Pinpoint ionization chamber, and a PTW 34 001 Roos ionization chamber. The IMBL beam height is limited to approximately 2 mm. To produce clinically useful beams of a few centimetres the beam must be scanned in the vertical direction. In practice it is the patient/detector that is scanned and the scanning velocity defines the dose that is delivered. The calorimeter, FAC, and Roos chamber measure the dose area product which is then converted to central axis dose with the scanned beam area derived from Monte Carlo (MC) simulations and film measurements. The Pinpoint chamber measures the central axis dose directly and does not require beam area measurements. The calorimeter and FAC measure dose from first principles. The calorimetry requires conversion of the measured absorbed dose to graphite to absorbed dose to water using MC calculations with the EGSnrc code. Air kerma measurements from the free air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. The two ionization chambers are secondary standards requiring calibration with kilovoltage x-ray tubes. The Roos and Pinpoint chambers were calibrated against the Australian primary standard for air kerma at the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Agreement of order 2% or better was obtained between the calorimetry and ionization chambers. The FAC measured a dose 3-5% higher than the calorimetry, within the stated uncertainties.
Serraes, Brecht; Beeckman, Dimitri
2016-01-01
The aim of this study was to investigate the incidence and risk factors for developing pressure injuries (PIs) in patients placed on a static air support surfaces: mattress overlay, heel wedge, and seat cushion. Multicenter cohort study. The sample comprised 176 residents; their mean age was 87 (SD = 6.76) years; their mean Braden Scale score was 14 (SD = 2.54). The study was performed on a convenience sample of 6 nursing homes in Belgium. Data were collected on 23 care units. The primary outcome measure, cumulative PI incidence (category [stage] II-IV) over a 30-day observation period, was calculated. Pressure injury occurrence was defined according to the 2014 European and US National Pressure Injury Advisory panels, Pan Pacific Pressure Injury Alliance classification system. The PI incidence for category (stage) II-IV was 5.1%. Six residents (3.4%) developed a category II PI, and 3 (1.7%) developed a category III PI; no category IV ulcers occurred. No significant risk factors for category II-IV PIs were identified using multivariate logistic regression. Time of sitting in a chair was found to be a risk factor for development of nonblanchable erythema (category I PI) (odds ratio = 21.608; 95% confidence interval [CI], 20.510-22.812; P = .013). The median time to develop a category II-IV PI was 16 days (interquartile range = 2-26). The interrater reliability between the observations of the researcher and nurses on-site was almost perfect (0.86; 95% CI, 0.81-0.91). We found a low incidence of PIs when using a static air overlay mattress for patients at risk in a nursing home population. Static air support surfaces, alongside patient-tailored patient repositioning protocols, should be considered to prevent PIs in this patient population.
NASA Astrophysics Data System (ADS)
Laurent, Olivier; Yver Kwok, Camille; Guemri, Ali; Philippon, Carole; Rivier, Leonard; Ramonet, Michel
2017-04-01
Due to the high variability of the water vapor content in the atmosphere, the mole fraction of trace gas such as greenhouse gas (GHG) in the atmosphere is usually presented as mole fraction in dry air. In consequence, the first technology used for GHG measurement, gas chromatography or non-dispersive infra-red spectroscopy, required to dry the air sample prior to analysis at a dew point lower than -50°C. The emergence of new GHG analyzers using infrared Enhanced Cavity Spectroscopy which measure the water vapor content in the air sample, allows providing the dry mole fraction of GHG without any drying system upstream by applying appropriate correction of the water vapor effects (dilution, pressure broadening…). In the framework of ICOS, a European research infrastructure aiming to provide harmonized high precision data for advanced research on carbon cycle and GHG budgets over Europe, the Metrology Lab of the Atmosphere Thematic Centre (ATC), located at LSCE in France, is mainly dedicated to elaborating measurement protocols and evaluating performance of GHG analyzers. Among the different tests conducted to characterize the metrological performance, the Metrology Lab focuses on the water vapor correction to apply on the GHG measurement. Most of the analyzers tested at the Metrology Lab are based on Cavity Enhanced Spectroscopy measuring the ICOS mandatory species, CO2, CH4 and CO. This presentation presents the results of the performance assessment of the manufacturer built-in water vapor correction and the possible improvement. Thanks to the large number of instrument tested, the presentation provides a performance overview of the GHG analyzers deployed in the ICOS atmospheric station network. Finally the performance of the water vapor correction will be discussed in regard of the performance obtained by using a drying system.
Plasma volume shifts with immersion at rest and two exercise intensities.
Ertl, A C; Bernauer, E M; Hom, C A
1991-04-01
Eight men were studied to determine the effect of cycling exercise on plasma volume (PV) during water immersion to the xiphoid process (WIX). In all protocols the subjects were seated upright. After 30 min of rest, subjects were immersed in 34.5 degrees C water and seated on a cycling ergometer. During three 1 h WIX protocols, subjects either remained at rest (No Ex) or pedaled from minutes 20 to 30 at 38% (Ex1) or 62% (Ex2) of peak oxygen consumption (VO2peak). Hematocrit (Hct) and hemoglobin concentration [( Hb]) from venous blood samples were compared pre-WIX and at minutes 20, 30, 40, and 60. Percent change in PV (delta PV) was calculated from pre-WIX Hct and [Hb] within each protocol. Hct and [Hb] decreased after 20 min of resting WIX (P less than 0.017). In the No Ex protocol, there were no further significant changes in these variables, with delta PV values of +10.4% at minute 20 and at a peak of +13.5% at minute 40. In Ex1 and Ex2, cycling increased Hct and [Hb] (P less than 0.01, minute 30 vs No Ex), with delta PV values at minute 30 of +3.7% and -0.9%, respectively, vs +12.8% in No Ex. Minute 60 values between protocols were not significantly different (mean delta PV of +10.8 +/- 0.6% SD). The hemodilution associated with WIX was either partially or completely attenuated by cycling exercise; the degree of hemoconcentration was related to exercise intensity. The exercise-induced hemoconcentration was reversed by 30 min of resting WIX. Exercise during WIX appears to cause similar decreases in PV, as does exercise in air provided that postural hemoconcentration prior to exercise is not already maximal.
A protocol was developed to rapidly assess the efficiency of chemical washing for the removal of excess biomass from biotrickling filters for waste air treatment. Although the experiment was performed on a small scale, conditions were chosen to simulate application in full-scale ...
School Indoor Air Quality Best Management Practices Manual.
ERIC Educational Resources Information Center
Hall, Richard; Ellis, Richard; Hardin, Tim
This manual, written in response to requirements of the Washington State legislature, focuses on practices which can be undertaken during the siting, design, construction, or renovation of a school, recommends practices to help ensure good indoor air quality during building occupancy, and suggests protocols and useful reference documents for…
The National Oceanic and Atmospheric Administration recently sponsored the New England Forecasting Pilot Program to serve as a "test bed" for chemical forecasting by providing all of the elements of a National Air Quality Forecasting System, including the development and implemen...
Lequy, Emeline; Saby, Nicolas P A; Ilyin, Ilia; Bourin, Aude; Sauvage, Stéphane; Leblond, Sébastien
2017-07-15
Air pollution in trace elements (TE) remains a concern for public health in Europe. For this reasons, networks of air pollution concentrations or exposure are deployed, including a moss bio-monitoring programme in Europe. Spatial determinants of TE concentrations in mosses remain unclear. In this study, the French dataset of TE in mosses is analyzed by spatial autoregressive model to account for spatial structure of the data and several variables proven or suspected to affect TE concentrations in mosses. Such variables include source (atmospheric deposition and soil concentrations), protocol (sampling month, collector, and moss species), and environment (forest type and canopy density, distance to the coast or the highway, and elevation). Modeled atmospheric deposition was only available for Cd and Pb and was one of the main explanatory variables of the concentrations in mosses. Predicted soil content was also an important explanatory variable except for Cr, Ni, and Zn. However, the moss species was the main factor for all the studied TE. The other environmental variables affected differently the TE. In particular, the forest type and canopy density were important in most cases. These results stress the need for further research on the effect of the moss species on the capture and retention of TE, as well as for accounting for several variables and the spatial structure of the data in statistical analyses. Copyright © 2017 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units E Appendix E to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units E Appendix E to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION...
Spectrometric Analysis for Pulse Jet Mixer Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
ZEIGLER, KRISTINE
2004-07-12
The Analytical Development Section (ADS) was tasked with providing support for a Hanford River Protection Program-Waste Treatment Program (RPP-WTP) project test involving absorption analysis for non-Newtonian pulse jet mixer testing for small scale (PJM) and prototype (CRV) tanks with sparging. Tanks filled with clay were mixed with various amounts of powdered dye as a tracer. The objective of the entire project was to determine the best mixing protocol (nozzle velocity, number of spargers used, total air flow, etc.) by determining the percent mixed volume through the use of an ultraviolet-visible (UV-Vis) spectrometer. The dye concentration within the sample could bemore » correlated to the volume fraction mixed in the tank. Samples were received in vials, a series of dilutions were generated from the clay, allowed to equilibrate, then centrifuged and siphoned for the supernate liquid to analyze by absorption spectroscopy. Equilibration of the samples and thorough mixing of the samples were a continuous issue with dilution curves being difficult to obtain. Despite these technical issues, useful data was obtained for evaluation of various mix conditions.« less
Woodall, Lucy C; Gwinnett, Claire; Packer, Margaret; Thompson, Richard C; Robinson, Laura F; Paterson, Gordon L J
2015-06-15
There is growing evidence of extensive pollution of the environment by microplastic, with microfibres representing a large proportion of the microplastics seen in marine sediments. Since microfibres are ubiquitous in the environment, present in the laboratory air and water, evaluating microplastic pollution is difficult. Incidental contamination is highly likely unless strict control measures are employed. Here we describe methods developed to minimize the amount of incidental post-sampling contamination when quantifying marine microfibre pollution. We show that our protocol, adapted from the field of forensic fibre examination, reduces fibre abundance by 90% and enables the quick screening of fibre populations. These methods therefore allow an accurate estimate of microplastics polluting marine sediments. In a case study from a series of samples collected on a research vessel, we use these methods to highlight the prevalence of microfibres as marine microplastics. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Representativeness of laboratory sampling procedures for the analysis of trace metals in soil.
Dubé, Jean-Sébastien; Boudreault, Jean-Philippe; Bost, Régis; Sona, Mirela; Duhaime, François; Éthier, Yannic
2015-08-01
This study was conducted to assess the representativeness of laboratory sampling protocols for purposes of trace metal analysis in soil. Five laboratory protocols were compared, including conventional grab sampling, to assess the influence of sectorial splitting, sieving, and grinding on measured trace metal concentrations and their variability. It was concluded that grinding was the most important factor in controlling the variability of trace metal concentrations. Grinding increased the reproducibility of sample mass reduction by rotary sectorial splitting by up to two orders of magnitude. Combined with rotary sectorial splitting, grinding increased the reproducibility of trace metal concentrations by almost three orders of magnitude compared to grab sampling. Moreover, results showed that if grinding is used as part of a mass reduction protocol by sectorial splitting, the effect of sieving on reproducibility became insignificant. Gy's sampling theory and practice was also used to analyze the aforementioned sampling protocols. While the theoretical relative variances calculated for each sampling protocol qualitatively agreed with the experimental variances, their quantitative agreement was very poor. It was assumed that the parameters used in the calculation of theoretical sampling variances may not correctly estimate the constitutional heterogeneity of soils or soil-like materials. Finally, the results have highlighted the pitfalls of grab sampling, namely, the fact that it does not exert control over incorrect sampling errors and that it is strongly affected by distribution heterogeneity.
Sticky trap and stem-tap sampling protocols for the Asian citrus psyllid (Hemiptera: Psyllidae)
USDA-ARS?s Scientific Manuscript database
Sampling statistics were obtained to develop a sampling protocol for estimating numbers of adult Diaphorina citri in citrus using two different sampling methods: yellow sticky traps and stem–tap samples. A 4.0 ha block of mature orange trees was stratified into ten 0.4 ha strata and sampled using...
Incident-response monitoring technologies for aircraft cabin air quality
NASA Astrophysics Data System (ADS)
Magoha, Paul W.
Poor air quality in commercial aircraft cabins can be caused by volatile organophosphorus (OP) compounds emitted from the jet engine bleed air system during smoke/fume incidents. Tri-cresyl phosphate (TCP), a common anti-wear additive in turbine engine oils, is an important component in today's global aircraft operations. However, exposure to TCP increases risks of certain adverse health effects. This research analyzed used aircraft cabin air filters for jet engine oil contaminants and designed a jet engine bleed air simulator (BAS) to replicate smoke/fume incidents caused by pyrolysis of jet engine oil. Field emission scanning electron microscopy (FESEM) with X-ray energy dispersive spectroscopy (EDS) and neutron activation analysis (NAA) were used for elemental analysis of filters, and gas chromatography interfaced with mass spectrometry (GC/MS) was used to analyze used filters to determine TCP isomers. The filter analysis study involved 110 used and 90 incident filters. Clean air filter samples exposed to different bleed air conditions simulating cabin air contamination incidents were also analyzed by FESEM/EDS, NAA, and GC/MS. Experiments were conducted on a BAS at various bleed air conditions typical of an operating jet engine so that the effects of temperature and pressure variations on jet engine oil aerosol formation could be determined. The GC/MS analysis of both used and incident filters characterized tri- m-cresyl phosphate (TmCP) and tri-p-cresyl phosphate (TpCP) by a base peak of an m/z = 368, with corresponding retention times of 21.9 and 23.4 minutes. The hydrocarbons in jet oil were characterized in the filters by a base peak pattern of an m/z = 85, 113. Using retention times and hydrocarbon thermal conductivity peak (TCP) pattern obtained from jet engine oil standards, five out of 110 used filters tested had oil markers. Meanwhile 22 out of 77 incident filters tested positive for oil fingerprints. Probit analysis of jet engine oil aerosols obtained from BAS tests by optical particle counter (OPC) revealed lognormal distributions with the mean (range) of geometric mass mean diameter (GMMD) = 0.41 (0.39, 0.45) microm and geometric standard deviation (GSD), sigma g = 1.92 (1.87, 1.98). FESEM/EDS and NAA techniques found a wide range of elements on filters, and further investigations of used filters are recommended using these techniques. The protocols for air and filter sampling and GC/MS analysis used in this study will increase the options available for detecting jet engine oil on cabin air filters. Such criteria could support policy development for compliance with cabin air quality standards during incidents.
Souday, Vincent; Koning, Nick J; Perez, Bruno; Grelon, Fabien; Mercat, Alain; Boer, Christa; Seegers, Valérie; Radermacher, Peter; Asfar, Pierre
2016-01-01
To test the hypothesis whether enriched air nitrox (EAN) breathing during simulated diving reduces decompression stress when compared to compressed air breathing as assessed by intravascular bubble formation after decompression. Human volunteers underwent a first simulated dive breathing compressed air to include subjects prone to post-decompression venous gas bubbling. Twelve subjects prone to bubbling underwent a double-blind, randomized, cross-over trial including one simulated dive breathing compressed air, and one dive breathing EAN (36% O2) in a hyperbaric chamber, with identical diving profiles (28 msw for 55 minutes). Intravascular bubble formation was assessed after decompression using pulmonary artery pulsed Doppler. Twelve subjects showing high bubble production were included for the cross-over trial, and all completed the experimental protocol. In the randomized protocol, EAN significantly reduced the bubble score at all time points (cumulative bubble scores: 1 [0-3.5] vs. 8 [4.5-10]; P < 0.001). Three decompression incidents, all presenting as cutaneous itching, occurred in the air versus zero in the EAN group (P = 0.217). Weak correlations were observed between bubble scores and age or body mass index, respectively. EAN breathing markedly reduces venous gas bubble emboli after decompression in volunteers selected for susceptibility for intravascular bubble formation. When using similar diving profiles and avoiding oxygen toxicity limits, EAN increases safety of diving as compared to compressed air breathing. ISRCTN 31681480.
21 CFR 660.6 - Samples; protocols; official release.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Hepatitis B Surface Antigen § 660.6 Samples; protocols; official release. (a) Samples. (1) For the purposes... of official release is no longer required under paragraph (c)(2) of this section. (ii) One sample at... required under paragraph (c)(2) of this section. The sample submitted at the 90-day interval shall be from...
21 CFR 660.6 - Samples; protocols; official release.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Hepatitis B Surface Antigen § 660.6 Samples; protocols; official release. (a) Samples. (1) For the purposes... of official release is no longer required under paragraph (c)(2) of this section. (ii) One sample at... required under paragraph (c)(2) of this section. The sample submitted at the 90-day interval shall be from...
21 CFR 660.6 - Samples; protocols; official release.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Hepatitis B Surface Antigen § 660.6 Samples; protocols; official release. (a) Samples. (1) For the purposes... of official release is no longer required under paragraph (c)(2) of this section. (ii) One sample at... required under paragraph (c)(2) of this section. The sample submitted at the 90-day interval shall be from...
A new real-time PCR protocol for detection of avian haemosporidians.
Bell, Jeffrey A; Weckstein, Jason D; Fecchio, Alan; Tkach, Vasyl V
2015-07-19
Birds possess the most diverse assemblage of haemosporidian parasites; including three genera, Plasmodium, Haemoproteus, and Leucocytozoon. Currently there are over 200 morphologically identified avian haemosporidian species, although true species richness is unknown due to great genetic diversity and insufficient sampling in highly diverse regions. Studies aimed at surveying haemosporidian diversity involve collecting and screening samples from hundreds to thousands of individuals. Currently, screening relies on microscopy and/or single or nested standard PCR. Although effective, these methods are time and resource consuming, and in the case of microscopy require substantial expertise. Here we report a newly developed real-time PCR protocol designed to quickly and reliably detect all three genera of avian haemosporidians in a single biochemical reaction. Using available DNA sequences from avian haemosporidians we designed primers R330F and R480RL, which flank a 182 base pair fragment of mitochondrial conserved rDNA. These primers were initially tested using real-time PCR on samples from Malawi, Africa, previously screened for avian haemosporidians using traditional nested PCR. Our real time protocol was further tested on 94 samples from the Cerrado biome of Brazil, previously screened using a single PCR assay for haemosporidian parasites. These samples were also amplified using modified nested PCR protocols, allowing for comparisons between the three different screening methods (single PCR, nested PCR, real-time PCR). The real-time PCR protocol successfully identified all three genera of avian haemosporidians from both single and mixed infections previously detected from Malawi. There was no significant difference between the three different screening protocols used for the 94 samples from the Brazilian Cerrado (χ(2) = 0.3429, df = 2, P = 0.842). After proving effective, the real-time protocol was used to screen 2113 Brazilian samples, identifying 693 positive samples. Our real-time PCR assay proved as effective as two widely used molecular screening techniques, single PCR and nested PCR. However, the real-time protocol has the distinct advantage of detecting all three genera in a single reaction, which significantly increases efficiency by greatly decreasing screening time and cost. Our real-time PCR protocol is therefore a valuable tool in the quickly expanding field of avian haemosporidian research.
Air pollution exposure--a trigger for myocardial infarction?
Berglind, Niklas; Ljungman, Petter; Möller, Jette; Hallqvist, Johan; Nyberg, Fredrik; Rosenqvist, Mårten; Pershagen, Göran; Bellander, Tom
2010-04-01
The association between ambient air pollution exposure and hospitalization for cardiovascular events has been reported in several studies with conflicting results. A case-crossover design was used to investigate the effects of air pollution in 660 first-time myocardial infarction cases in Stockholm in 1993-1994, interviewed shortly after diagnosis using a standard protocol. Air pollution data came from central urban background monitors. No associations were observed between the risk for onset of myocardial infarction and two-hour or 24-hour air pollution exposure. No evidence of susceptible subgroups was found. This study provides no support that moderately elevated air pollution levels trigger first-time myocardial infarction.
NASA Technical Reports Server (NTRS)
1981-01-01
The purpose of the Orbiting Quarantine Facility is to provide maximum protection of the terrestrial biosphere by ensuring that the returned Martian samples are safe to bring to Earth. The protocol designed to detect the presence of biologically active agents in the Martian soil is described. The protocol determines one of two things about the sample: (1) that it is free from nonterrestrial life forms and can be sent to a terrestrial containment facility where extensive chemical, biochemical, geological, and physical investigations can be conducted; or (2) that it exhibits "biological effects" of the type that dictate second order testing. The quarantine protocol is designed to be conducted on a small portion of the returned sample, leaving the bulk of the sample undisturbed for study on Earth.
COMPARISON OF USEPA FIELD SAMPLING METHODS FOR BENTHIC MACROINVERTEBRATE STUDIES
Two U.S. Environmental Protection Agency (USEPA) macroinvertebrate sampling protocols were compared in the Mid-Atlantic Highlands region. The Environmental Monitoring and Assessment Program (EMAP) wadeable streams protocol results in a single composite sample from nine transects...
Vaccari, L; Birarda, G; Businaro, L; Pacor, S; Grenci, G
2012-06-05
Until nowadays most infrared microspectroscopy (IRMS) experiments on biological specimens (i.e., tissues or cells) have been routinely carried out on fixed or dried samples in order to circumvent water absorption problems. In this paper, we demonstrate the possibility to widen the range of in-vitro IRMS experiments to vibrational analysis of live cellular samples, thanks to the development of novel biocompatible IR-visible transparent microfluidic devices (MD). In order to highlight the biological relevance of IRMS in MD (MD-IRMS), we performed a systematic exploration of the biochemical alterations induced by different fixation protocols, ethanol 70% and formaldehyde solution 4%, as well as air-drying on U937 leukemic monocytes by comparing their IR vibrational features with the live U937 counterpart. Both fixation and air-drying procedures affected lipid composition and order as well as protein structure at a different extent while they both induced structural alterations in nucleic acids. Therefore, only IRMS of live cells can provide reliable information on both DNA and RNA structure and on their cellular dynamic. In summary, we show that MD-IRMS of live cells is feasible, reliable, and biologically relevant to be recognized as a label-free cell-based assay.
Ulm, Ashley; Mayhew, Christopher N.; Debley, Jason; Khurana Hershey, Gurjit K.; Ji, Hong
2016-01-01
Nasal epithelial cells (NECs) are the part of the airways that respond to air pollutants and are the first cells infected with respiratory viruses. They are also involved in many airway diseases through their innate immune response and interaction with immune and airway stromal cells. NECs are of particular interest for studies in children due to their accessibility during clinical visits. Human induced pluripotent stem cells (iPSCs) have been generated from multiple cell types and are a powerful tool for modeling human development and disease, as well as for their potential applications in regenerative medicine. This is the first protocol to lay out methods for successful generation of iPSCs from NECs derived from pediatric participants for research purposes. It describes how to obtain nasal epithelial cells from children, how to generate primary NEC cultures from these samples, and how to reprogram primary NECs into well-characterized iPSCs. Nasal mucosa samples are useful in epidemiological studies related to the effects of air pollution in children, and provide an important tool for studying airway disease. Primary nasal cells and iPSCs derived from them can be a tool for providing unlimited material for patient-specific research in diverse areas of airway epithelial biology, including asthma and COPD research. PMID:27022951
Raggi, Alessandra; Sanna, Tiziana; Mazzetti, Magda; Orsi, Alessandra; Zanni, Angela; Farruggia, Patrizia
2017-01-01
The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in “at rest” conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols. PMID:29283367
Ulm, Ashley; Mayhew, Christopher N; Debley, Jason; Khurana Hershey, Gurjit K; Ji, Hong
2016-03-10
Nasal epithelial cells (NECs) are the part of the airways that respond to air pollutants and are the first cells infected with respiratory viruses. They are also involved in many airway diseases through their innate immune response and interaction with immune and airway stromal cells. NECs are of particular interest for studies in children due to their accessibility during clinical visits. Human induced pluripotent stem cells (iPSCs) have been generated from multiple cell types and are a powerful tool for modeling human development and disease, as well as for their potential applications in regenerative medicine. This is the first protocol to lay out methods for successful generation of iPSCs from NECs derived from pediatric participants for research purposes. It describes how to obtain nasal epithelial cells from children, how to generate primary NEC cultures from these samples, and how to reprogram primary NECs into well-characterized iPSCs. Nasal mucosa samples are useful in epidemiological studies related to the effects of air pollution in children, and provide an important tool for studying airway disease. Primary nasal cells and iPSCs derived from them can be a tool for providing unlimited material for patient-specific research in diverse areas of airway epithelial biology, including asthma and COPD research.
A Field Comparison of Sampling Protocols for Measuring Lead in Drinking Water
US EPA Region 5 conducted a sampling study that demonstrates existing sampling protocols used for the Lead and Copper Rule (LCR) underestimate peak and probable mass of lead released in a system with lead service lines (LSLs). This comparative stagnation sampling was conducted i...
NASA Astrophysics Data System (ADS)
Engström, J. E.; Leck, C.
2011-08-01
The presented filter-based optical method for determination of soot (light absorbing carbon or Black Carbon, BC) can be implemented in the field under primitive conditions and at low cost. This enables researchers with small economical means to perform monitoring at remote locations, especially in the Asia where it is much needed. One concern when applying filter-based optical measurements of BC is that they suffer from systematic errors due to the light scattering of non-absorbing particles co-deposited on the filter, such as inorganic salts and mineral dust. In addition to an optical correction of the non-absorbing material this study provides a protocol for correction of light scattering based on the chemical quantification of the material, which is a novelty. A newly designed photometer was implemented to measure light transmission on particle accumulating filters, which includes an additional sensor recording backscattered light. The choice of polycarbonate membrane filters avoided high chemical blank values and reduced errors associated with length of the light path through the filter. Two protocols for corrections were applied to aerosol samples collected at the Maldives Climate Observatory Hanimaadhoo during episodes with either continentally influenced air from the Indian/Arabian subcontinents (winter season) or pristine air from the Southern Indian Ocean (summer monsoon). The two ways of correction (optical and chemical) lowered the particle light absorption of BC by 63 to 61 %, respectively, for data from the Arabian Sea sourced group, resulting in median BC absorption coefficients of 4.2 and 3.5 Mm-1. Corresponding values for the South Indian Ocean data were 69 and 97 % (0.38 and 0.02 Mm-1). A comparison with other studies in the area indicated an overestimation of their BC levels, by up to two orders of magnitude. This raises the necessity for chemical correction protocols on optical filter-based determinations of BC, before even the sign on the radiative forcing based on their effects can be assessed.
Cho, S H; Lowenstein, J R; Balter, P A; Wells, N H; Hanson, W F
2000-01-01
A new calibration protocol, developed by the AAPM Task Group 51 (TG-51) to replace the TG-21 protocol, is based on an absorbed-dose to water standard and calibration factor (N(D,w)), while the TG-21 protocol is based on an exposure (or air-kerma) standard and calibration factor (N(x)). Because of differences between these standards and the two protocols, the results of clinical reference dosimetry based on TG-51 may be somewhat different from those based on TG-21. The Radiological Physics Center has conducted a systematic comparison between the two protocols, in which photon and electron beam outputs following both protocols were compared under identical conditions. Cylindrical chambers used in this study were selected from the list given in the TG-51 report, covering the majority of current manufacturers. Measured ratios between absorbed-dose and air-kerma calibration factors, derived from the standards traceable to the NIST, were compared with calculated values using the TG-21 protocol. The comparison suggests that there is roughly a 1% discrepancy between measured and calculated ratios. This discrepancy may provide a reasonable measure of possible changes between the absorbed-dose to water determined by TG-51 and that determined by TG-21 for photon beam calibrations. The typical change in a 6 MV photon beam calibration following the implementation of the TG-51 protocol was about 1%, regardless of the chamber used, and the change was somewhat smaller for an 18 MV photon beam. On the other hand, the results for 9 and 16 MeV electron beams show larger changes up to 2%, perhaps because of the updated electron stopping power data used for the TG-51 protocol, in addition to the inherent 1% discrepancy presented in the calibration factors. The results also indicate that the changes may be dependent on the electron energy.
Judges' Agreement and Disagreement Patterns When Encoding Verbal Protocols.
ERIC Educational Resources Information Center
Schael, Jocelyne; Dionne, Jean-Paul
The basis of agreement or disagreement among judges/evaluators when applying a coding scheme to concurrent verbal protocols was studied. The sample included 20 university graduates, from varied backgrounds; 10 subjects had and 10 subjects did not have experience in protocol analysis. The total sample was divided into four balanced groups according…
40 CFR 1048.110 - How must my engines diagnose malfunctions?
Code of Federal Regulations, 2013 CFR
2013-07-01
... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...
40 CFR 1048.110 - How must my engines diagnose malfunctions?
Code of Federal Regulations, 2012 CFR
2012-07-01
... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...
40 CFR 1048.110 - How must my engines diagnose malfunctions?
Code of Federal Regulations, 2014 CFR
2014-07-01
... control of air-fuel ratios: (a) Equip your engines with a diagnostic system. Starting in the 2007 model... malfunction whenever the air-fuel ratio does not cross stoichiometry for one minute of intended closed-loop operation. You may use other diagnostic strategies if we approve them in advance. (2) If the protocol...
Green buildings: Implications for acousticians
NASA Astrophysics Data System (ADS)
Noble, Michael R.
2005-04-01
This presentation will deal with the practical implications of green design protocols of the US Green Building Council on interior acoustics of buildings. Three areas of particular consequence to acousticians will be discussed. Ventilation Systems: reduced energy consumption goals dictate reliance on natural cooling and ventilation using ambient air when possible. The consequent large openings in the building envelope to bring fresh air into rooms, and similar sized openings to transfer the mixed air out, can severely compromise the noise isolation of the rooms concerned. Radiant Cooling: the heavy concrete floors of buildings can be used as a thermal flywheel to lessen the cooling load, which forces the concrete ceilings to be exposed to the occupied rooms for heat transfer, and strictly limits the application of acoustical absorption on the ceilings. This challenges the room acoustics design. Green Materials: the LEED protocols require the elimination of potentially harmful finishes, including fibrous materials which may impact air quality or contribute to health problems. Since the backbone of sound absorption is glass and mineral fibres, this further challenges provision of superior room acoustics. Examples and commentary will be provided based on current and recent projects.
Study of Tranexamic Acid During Air Medical Prehospital Transport Trial (STAAMP trial)
2015-10-01
AWARD NUMBER: W81XWH-13-2-0080 TITLE: Study of Tranexamic Acid During Air Medical Prehospital Transport Trial (STAAMP trial) PRINCIPAL INVESTIGATOR...TITLE AND SUBTITLE 5a. CONTRACT NUMBER Study of Tranexamic Acid During Air Medical Prehospital Transport Trial (STAAMP trial) 5b. GRANT NUMBER W81XWH...IRB approval regarding changes to the protocol language. 15. SUBJECT TERMS Prehospital; Tranexamic acid 16. SECURITY CLASSIFICATION OF: 17. LIMITATION
Sarmento, Hugo R; Campos, Fernanda; Sousa, Rafael S; Machado, Joao P B; Souza, Rodrigo O A; Bottino, Marco A; Ozcan, Mutlu
2014-07-01
This study evaluated the influence of air-particle abrasion protocols on the surface roughness (SR) of zirconia and the shear bond strength (SBS) of dual-polymerized resin cement to this ceramic. Sintered zirconia blocks (n = 115) (Lava, 3M ESPE) were embedded in acrylic resin and polished. The specimens were divided according to the 'particle type' (Al: 110 µm Al2O3; Si: 110 µm SiO2) and 'pressure' factors (2.5 or 3.5 bar) (n = 3 per group): (a) Control (no air-abrasion); (b) Al2.5; (c) Si2.5; (d) Al3.5; (e) Si3.5. SR (Ra) was measured 3-times from each specimen after 20 s of air-abrasion (distance: 10 mm) using a digital optical profilometer. Surface topography was evaluated under SEM analyses. For the SBS test, 'particle type', 'pressure' and 'thermocycling' (TC) factors were considered (n = 10; n = 10 per group): Control (no air-abrasion); Al2.5; Si2.5; Al3.5; Si3.5; ControlTC; Al2.5TC; Si2.5TC; Al3.5TC; Si3.5TC. After silane application, resin cement (Panavia F2.0) was bonded and polymerized. Specimens were thermocycled (6.000 cycles, 5-55°C) and subjected to SBS (1 mm/min). Data were analyzed using ANOVA, Tukey's and Dunnett tests (5%). 'Particle' (p = 0.0001) and 'pressure' (p = 0.0001) factors significantly affected the SR. All protocols significantly increased the SR (Al2.5: 0.45 ± 0.02; Si2.5: 0.39 ± 0.01; Al3.5: 0.80 ± 0.01; Si3.5: 0.64 ± 0.01 µm) compared to the control group (0.16 ± 0.01 µm). For SBS, only 'particle' factor significantly affected the results (p = 0.015). The SiO2 groups presented significantly higher SBS results than Al2O3 (Al2.5: 4.78 ± 1.86; Si2.5: 7.17 ± 2.62; Al3.5: 4.97 ± 3.74; Si3.5: 9.14 ± 4.09 MPa) and the control group (3.67 ± 3.0 MPa). All TC specimens presented spontaneous debondings. SEM analysis showed that Al2O3 created damage in zirconia in the form of grooves, different from those observed with SiO2 groups. Air-abrasion with 110 µm Al2O3 resulted in higher roughness, but air-abrasion protocols with SiO2 promoted better adhesion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Romberger, Jeff
The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions.
1985-03-01
model referred to by the study group . IMCKIiN cuINICATION 31215FOR SDATA TWSU•l Sa *BSTtEO POOTO• AA14FTICT’WI PEM1 ITS ...operating systems, compared the DOD and ISO networking protocol architecture models , the protocols for LAN’s developed by the IEEE and ANSI, reviewed and...be initiated, so as to provide the Air Force a roadmap to guide its * "technology develop •ents. 4,’ /LAN 3-4 .°. SECTION 4.0
Thermogravimetric Analysis of Single-Wall Carbon Nanotubes
NASA Technical Reports Server (NTRS)
Arepalli, Sivram; Nikolaev, Pavel; Gorelik, Olga
2010-01-01
An improved protocol for thermogravimetric analysis (TGA) of samples of single-wall carbon nanotube (SWCNT) material has been developed to increase the degree of consistency among results so that meaningful comparisons can be made among different samples. This improved TGA protocol is suitable for incorporation into the protocol for characterization of carbon nanotube material. In most cases, TGA of carbon nanotube materials is performed in gas mixtures that contain oxygen at various concentrations. The improved protocol is summarized.
NASA Astrophysics Data System (ADS)
Derwent, R. G.; Simmonds, P. G.; Greally, B. R.; O'doherty, S.; McCulloch, A.; Manning, A.; Reimann, S.; Folini, D.; Vollmer, M. K.
The mixing ratios of HCFC-141b (1,1-dichlorofluoroethane) and HCFC-142b (1-chloro-1,1-difluoroethane) have been rising steadily in baseline air at Mace Head, Ireland over the 10-year period from 1994 to 2004. These HCFCs are widely used replacements for the chlorofluorocarbons phased out under the Montreal Protocol and its subsequent amendments. Analysis of the HCFC content of regionally-polluted air arriving at Mace Head from the European continent shows that European emissions reached a peak during 2000-2001 and have declined subsequently, following the phase-out in their usage. European emissions of HCFC-141b have been further constrained by observations at the High-Alpine Jungfraujoch site. The reductions are consistent with the phase-out of HCFC production and use from the year 2001 onwards mandated by European regulations designed to exceed the requirements of the Montreal Protocol.
An inventory and monitoring plan for a Sonoran Desert ecosystem; Barry M. Goldwater Range-West
Villarreal, Miguel L.; van Riper, Charles; Lovich, Robert E.; Palmer, Robert L.; Nauman, Travis; Studd, Sarah E.; Drake, Sam; Rosenberg, Abigail S.; Malusa, Jim; Pearce, Ronald L.
2011-01-01
Marine Corps Air Station Yuma manages the Barry M. Goldwater Range-West, which encompasses approximately 2,800 square kilometers of Sonoran Desert habitat in southwestern Arizona. The Barry M. Goldwater Range is a major U.S. military installation designed as an air combat training location for the U.S. Marine Corps and U.S. Air Force, but it also includes some of the most pristine desert habitat in the United States. In an effort to ensure the long-term viability of this unique natural resource, the U.S. Geological Survey (USGS) has developed an Integrated Natural Resources Management Plan and Inventory and Monitoring Plan to guide natural resource management of the Barry M. Goldwater Range-West. This Inventory and Monitoring Plan provides a framework for long-term ecosystem monitoring on Barry M. Goldwater Range-West lands by identifying existing and potential threats to ecosystem function, prioritizing resources for monitoring, and providing information and protocols necessary to initiate a long-term ecosystem monitoring program. The Inventory and Monitoring Plan and related protocols were developed through extensive review of existing Sonoran Desert monitoring programs and monitoring literature and through a 2-day workshop with resource managers, monitoring experts, and other stakeholders. The Barry M. Goldwater Range-West Inventory and Monitoring Plan stresses the importance of regional monitoring partnerships and protocol standardization for understanding landscape-scale ecosystem changes in the Sonoran Desert; information and protocols contained within the plan may also be of interest to land managers engaged in large-scale ecosystem monitoring and adaptive management of other arid regions.
Sanchez, Sophie; Fernandez, Vincent; Pierce, Stephanie E; Tafforeau, Paul
2013-09-01
Propagation phase-contrast synchrotron radiation microtomography (PPC-SRμCT) has proved to be very successful for examining fossils. Because fossils range widely in taphonomic preservation, size, shape and density, X-ray computed tomography protocols are constantly being developed and refined. Here we present a 1-h procedure that combines a filtered high-energy polychromatic beam with long-distance PPC-SRμCT (sample to detector: 4-16 m) and an attenuation protocol normalizing the absorption profile (tested on 13-cm-thick and 5.242 g cm(-3) locally dense samples but applicable to 20-cm-thick samples). This approach provides high-quality imaging results, which show marked improvement relative to results from images obtained without the attenuation protocol in apparent transmission, contrast and signal-to-noise ratio. The attenuation protocol involves immersing samples in a tube filled with aluminum or glass balls in association with a U-shaped aluminum profiler. This technique therefore provides access to a larger dynamic range of the detector used for tomographic reconstruction. This protocol homogenizes beam-hardening artifacts, thereby rendering it effective for use with conventional μCT scanners.
Osei, Frank A; Hayman, Joshua; Sutton, Nicole J; Pass, Robert H
2016-01-01
Background: Cardiac catheterizations expose both the patient and staff to the risks of ionizing radiation. Studies using the “air gap” technique (AGT) in various radiological procedures indicate that its use leads to reduction in radiation exposure but there are no data on its use for pediatric cardiac catheterization. The aim of this study was to retrospectively review the radiation exposure data for children weighing <20 kg during cardiac catheterizations using AGT and an “as low as reasonably achievable (ALARA)” radiation reduction protocol. Patients and Methods: All patients weighing <20 kg who underwent cardiac catheterization at the Children's Hospital at Montefiore (CHAM), New York, the United States from 05/2011 to 10/2013 were included. Transplant patients who underwent routine endomyocardial biopsy and those who had surgical procedures at the time of the catheterizations were excluded. The ALARA protocol was used in concert with AGT with the flat panel detector positioned 110 cm from the patient. Demographics, procedural data, and patient radiation exposure levels were collected and analyzed. Results: One-hundred and twenty-seven patients underwent 151 procedures within the study period. The median age was 1.2 years (range: 1 day to 7.9 years) and median weight was 8.8 kg (range: 1.9-19.7). Eighty-nine (59%) of the procedures were interventional. The median total fluoro time was 13 min [interquartile range (IQR) 7.3-21.8]. The median total air Kerma (K) product was 55.6 mGy (IQR 17.6-94.2) and dose area product (DAP) was 189 Gym2 (IQR 62.6-425.5). Conclusion: Use of a novel ALARA and AGT protocol for cardiac catheterizations in children markedly reduced radiation exposure to levels far below recently reported values. Abbreviations: AGT: Air gap technique, ALARA: As low as reasonably achievable. PMID:27011686
FIELD SAMPLING PROTOCOLS AND ANALYSIS
I have been asked to speak again to the environmental science class regarding actual research scenarios related to my work at Kerr Lab. I plan to discuss sampling protocols along with various field analyses performed during sampling activities. Many of the students have never see...
21 CFR 660.46 - Samples; protocols; official release.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Samples; protocols; official release. 660.46 Section 660.46 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., a sample of product not iodinated with 125I means a sample from each filling of each lot packaged as...
Choi, Sanghun; Hoffman, Eric A; Wenzel, Sally E; Castro, Mario; Lin, Ching-Long
2014-09-15
Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions. Copyright © 2014 the American Physiological Society.
Choi, Sanghun; Hoffman, Eric A.; Wenzel, Sally E.; Castro, Mario
2014-01-01
Lung air trapping is estimated via quantitative computed tomography (CT) using density threshold-based measures on an expiration scan. However, the effects of scanner differences and imaging protocol adherence on quantitative assessment are known to be problematic. This study investigates the effects of protocol differences, such as using different CT scanners and breath-hold coaches in a multicenter asthmatic study, and proposes new methods that can adjust intersite and intersubject variations. CT images of 50 healthy subjects and 42 nonsevere and 52 severe asthmatics at total lung capacity (TLC) and functional residual capacity (FRC) were acquired using three different scanners and two different coaching methods at three institutions. A fraction threshold-based approach based on the corrected Hounsfield unit of air with tracheal density was applied to quantify air trapping at FRC. The new air-trapping method was enhanced by adding a lung-shaped metric at TLC and the lobar ratio of air-volume change between TLC and FRC. The fraction-based air-trapping method is able to collapse air-trapping data of respective populations into distinct regression lines. Relative to a constant value-based clustering scheme, the slope-based clustering scheme shows the improved performance and reduced misclassification rate of healthy subjects. Furthermore, both lung shape and air-volume change are found to be discriminant variables for differentiating among three populations of healthy subjects and nonsevere and severe asthmatics. In conjunction with the lung shape and air-volume change, the fraction-based measure of air trapping enables differentiation of severe asthmatics from nonsevere asthmatics and nonsevere asthmatics from healthy subjects, critical for the development and evaluation of new therapeutic interventions. PMID:25103972
High-pressure freezing and freeze substitution of Arabidopsis for electron microscopy.
Austin, Jotham R
2014-01-01
The objectives of electron microscopy ultrastructural studies are to examine cellular architecture and relate the cell's structural machinery to dynamic functional roles. This aspiration is difficult to achieve if specimens have not been adequately preserved in a "living state"; hence specimen preparation is of the utmost importance for the success of any electron micrographic study. High-pressure freezing (HPF)/freeze substitution (FS) has long been recognized as the primer technique for the preservation of ultrastructure in biological samples. In most cases a basic HPF/freeze substitution protocol is sufficient to obtain superior ultrastructural preservation and structural contrast, which allows one to use more advanced microscopy techniques such as 3D electron tomography. However, for plant tissues, which have a thick cell wall, large water-filled vacuoles, and air spaces (all of which are detrimental to cryopreservation), these basic HPF/FS protocols often yield undesirable results. In particular, ice crystal artifacts and the staining of membrane systems are often poorly or negatively stained, which make 3D segmentation of a tomogram difficult. To overcome these problems, various aspects of the HPF/FS protocol can be altered, including the cryo-filler(s) used, freeze substitution cocktail, and the resin infiltration process. This chapter will describe these modifications for the preparation of plant tissues for routine electron microscopic studies, immunocytochemistry, and 3D tomographic electron imaging.
NASA Astrophysics Data System (ADS)
Bundke, Ulrich; Berg, Marcel; Franke, Harald; Zahn, Andreas; Boenisch, Harald; Perim de Faria, Julia; Berkes, Florian; Petzold, Andreas
2017-04-01
The European Research Infrastructure IAGOS (In-service Aircraft for a Global Observing System; www.iagos.org) responds to the increasing requests for long-term, routine in-situ observational data by using commercial passenger aircraft as measurement platforms. The infrastructure is built from two complementary approaches: The "CORE" component comprises the implementation and operation of autonomous instruments installed on up to 20 long-range aircraft of international airlines for continuous measurements of important reactive gases and greenhouse gases, as well as aerosol particles, dust and cloud particles. The fully automated instruments are designed for operation aboard the aircraft in unattended mode for several months and the data are transmitted automatically. The complementary "CARIBIC" component consists of the monthly deployment of a cargo container equipped with instrumentation for a larger suite of components. The CARIBIC container has equipment for measuring ozone, carbon monoxide, nitrogen oxides, water vapor and airborne particles. Furthermore the container is equipped with a system for collecting air samples. These air samples are analyzed in the laboratory. For each sample measurements for more than 40 trace gases including CFC's prohibited by the Montreal protocol, and all greenhouse gases are performed. The Interface described in this work is designed to host one of IAGOS CORE (Package2) instruments. Available are: P2a, P2b, measuring { NO_y} and {NO_x} em P2c, measuring the aerosol size-distribution (0.25
Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis
Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej
2016-01-01
Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world. PMID:28060297
Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis.
Kovač Viršek, Manca; Palatinus, Andreja; Koren, Špela; Peterlin, Monika; Horvat, Petra; Kržan, Andrej
2016-12-16
Microplastic pollution in the marine environment is a scientific topic that has received increasing attention over the last decade. The majority of scientific publications address microplastic pollution of the sea surface. The protocol below describes the methodology for sampling, sample preparation, separation and chemical identification of microplastic particles. A manta net fixed on an »A frame« attached to the side of the vessel was used for sampling. Microplastic particles caught in the cod end of the net were separated from samples by visual identification and use of stereomicroscopes. Particles were analyzed for their size using an image analysis program and for their chemical structure using ATR-FTIR and micro FTIR spectroscopy. The described protocol is in line with recommendations for microplastics monitoring published by the Marine Strategy Framework Directive (MSFD) Technical Subgroup on Marine Litter. This written protocol with video guide will support the work of researchers that deal with microplastics monitoring all over the world.
Dual-view plane illumination microscopy for rapid and spatially isotropic imaging
Kumar, Abhishek; Wu, Yicong; Christensen, Ryan; Chandris, Panagiotis; Gandler, William; McCreedy, Evan; Bokinsky, Alexandra; Colón-Ramos, Daniel A; Bao, Zhirong; McAuliffe, Matthew; Rondeau, Gary; Shroff, Hari
2015-01-01
We describe the construction and use of a compact dual-view inverted selective plane illumination microscope (diSPIM) for time-lapse volumetric (4D) imaging of living samples at subcellular resolution. Our protocol enables a biologist with some prior microscopy experience to assemble a diSPIM from commercially available parts, to align optics and test system performance, to prepare samples, and to control hardware and data processing with our software. Unlike existing light sheet microscopy protocols, our method does not require the sample to be embedded in agarose; instead, samples are prepared conventionally on glass coverslips. Tissue culture cells and Caenorhabditis elegans embryos are used as examples in this protocol; successful implementation of the protocol results in isotropic resolution and acquisition speeds up to several volumes per s on these samples. Assembling and verifying diSPIM performance takes ~6 d, sample preparation and data acquisition take up to 5 d and postprocessing takes 3–8 h, depending on the size of the data. PMID:25299154
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carbaugh, Eugene H.
2008-10-01
The origin of the approximate 24-hour urine sampling protocol used at Hanford for routine bioassay is attributed to an informal study done in the mid-1940s. While the actual data were never published and have been lost, anecdotal recollections by staff involved in the initial bioassay program design and administration suggest that the sampling protocol had a solid scientific basis. Numerous alternate methods for normalizing partial day samples to represent a total 24-hour collection have since been proposed and used, but no one method is obviously preferred.
Indoor air quality in a middle school, Part I: Use of CO2 as a tracer for effective ventilation.
Scheff, P A; Paulius, V K; Huang, S W; Conroy, L M
2000-11-01
The overall objective of the study was to evaluate the indoor air quality at a middle school with an emphasis on characterizing baseline conditions. The focus of this article is on the relationship between occupancy and measured concentrations of carbon dioxide, and an evaluation of the use of carbon dioxide as a tracer for ventilation in the school. The school was characterized as having no health complaints, good maintenance schedules, no carpeting within the classrooms or hallways, and no significant remodeling, and its officials had agreed to allow the sampling to take place during school hours. Monitoring followed the guidelines recommended in the "Preliminary Draft: Conceptual Standardized EPA Protocol For Characterizing Indoor Air Quality in School Buildings." Four indoor locations including the cafeteria, a science classroom, an art classroom, and the lobby outside the main office, and one outdoor location were sampled for various environmental comfort and pollutant parameters for one week in February 1997. A consistent relationship between hourly occupancy and corresponding carbon dioxide concentrations was seen. Carbon dioxide concentrations in the cafeteria, art room, and lobby were within specified American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) guidelines for comfort (< 1000 ppm). The science room had the highest concentrations (frequently exceeding 1000 ppm) due to high occupancy and non-functioning unit ventilators. Measured ventilation rates were within specified ASHRAE guidelines for the art room, cafeteria, and lobby. The science room, which relied on natural ventilation only, was not able to meet the ASHRAE guideline on one of the three days studied. The use of a completely mixed space, one compartment mass balance model with estimated CO2 generation rates and measured CO2 concentrations is shown to be a useful method for evaluating ventilation. Modeled effective ventilation, air changes per hour, and mixing factors reflected measured carbon dioxide concentrations and measured ventilation in each room. Mechanical ventilation afforded better mixing than natural ventilation. This study demonstrates the usefulness of collecting indoor CO2 and occupancy data when carrying out indoor air quality evaluations in schools.
A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Viso, M.; DeVincenzi, D. L.; Race, M. S.; Schad, P. J.; Stabekis, P. D.; Acevedo, S. E.; Rummel, J. D.
2002-01-01
In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.
Information Assurance within the United States Air Force
ERIC Educational Resources Information Center
Cherry, John D.
2010-01-01
According to the Department of Defense (DoD), a review of information assurance (IA) in the United States Air Force (USAF) in 2009, cyber security is jeopardized because of information loss. This situation has occurred in large part because of less than optimal training practices or adherence to training protocols. The purpose of this study was…
Tsai, Hsieh-Hung; Yuan, Chung-Shin; Hung, Chung-Hsuang; Lin, Chitsan; Lin, Yuan-Chung
2011-04-01
The influence of sea-land breezes (SLBs) on the spatial distribution and temporal variation of particulate matter (PM) in the atmosphere was investigated over coastal Taiwan. PM was simultaneously sampled at inland and offshore locations during three intensive sampling periods. The intensive PM sampling protocol was continuously conducted over a 48-hr period. During this time, PM2.5 and PM(2.5-10) (PM with aerodynamic diameters < 2.5 microm and between 2.5 and 10 microm, respectively) were simultaneously measured with dichotomous samplers at four sites (two inland and two offshore sites) and PM10 (PM with aerodynamic diameters < or =10 microm) was measured with beta-ray monitors at these same 4 sites and at 10 sites of the Taiwan Air Quality Monitoring Network. PM sampling on a mobile air quality monitoring boat was further conducted along the coastline to collect offshore PM using a beta-ray monitor and a dichotomous sampler. Data obtained from the inland sites (n=12) and offshore sites (n=2) were applied to plot the PM10 concentration contour using Surfer software. This study also used a three-dimensional meteorological model (Pennsylvania State University/National Center for Atmospheric Research Meteorological Model 5) and the Comprehensive Air Quality Model with Extensions to simulate surface wind fields and spatial distribution of PM10 over the coastal region during the intensive sampling periods. Spatial distribution of PM10 concentration was further used in investigating the influence of SLBs on the transport of PM10 over the coastal region. Field measurement and model simulation results showed that PM10 was transported back and forth across the coastline. In particular, a high PM10 concentration was observed at the inland sites during the day because of sea breezes, whereas a high PM10 concentration was detected offshore at night because of land breezes. This study revealed that the accumulation of PM in the near-ocean region because of SLBs influenced the tempospatial distribution of PM10 over the coastal region.
Colyar, Jessica M; Eggett, Dennis L; Steele, Frost M; Dunn, Michael L; Ogden, Lynn V
2009-09-01
The relative sensitivity of side-by-side and sequential monadic consumer liking protocols was compared. In the side-by-side evaluation, all samples were presented at once and evaluated together 1 characteristic at a time. In the sequential monadic evaluation, 1 sample was presented and evaluated on all characteristics, then returned before panelists received and evaluated another sample. Evaluations were conducted on orange juice, frankfurters, canned chili, potato chips, and applesauce. Five commercial brands, having a broad quality range, were selected as samples for each product category to assure a wide array of consumer liking scores. Without their knowledge, panelists rated the same 5 retail brands by 1 protocol and then 3 wk later by the other protocol. For 3 of the products, both protocols yielded the same order of overall liking. Slight differences in order of overall liking for the other 2 products were not significant. Of the 50 pairwise overall liking comparisons, 44 were in agreement. The different results obtained by the 2 protocols in order of liking and significance of paired comparisons were due to the experimental variation and differences in sensitivity. Hedonic liking scores were subjected to statistical power analyses and used to calculate minimum number of panelists required to achieve varying degrees of sensitivity when using side-by-side and sequential monadic protocols. In most cases, the side-by-side protocol was more sensitive, thus providing the same information with fewer panelists. Side-by-side protocol was less sensitive in cases where sensory fatigue was a factor.
GARBIERI, Thais Francini; BROZOSKI, Daniel Thomas; DIONÍSIO, Thiago José; SANTOS, Carlos Ferreira; NEVES, Lucimara Teixeira das
2017-01-01
Abstract Saliva when compared to blood collection has the following advantages: it requires no specialized personnel for collection, allows for remote collection by the patient, is painless, well accepted by participants, has decreased risks of disease transmission, does not clot, can be frozen before DNA extraction and possibly has a longer storage time. Objective and Material and Methods This study aimed to compare the quantity and quality of human DNA extracted from saliva that was fresh or frozen for three, six and twelve months using five different DNA extraction protocols: protocol 1 – Oragene™ commercial kit, protocol 2 – QIAamp DNA mini kit, protocol 3 – DNA extraction using ammonium acetate, protocol 4 – Instagene™ Matrix and protocol 5 – Instagene™ Matrix diluted 1:1 using proteinase K and 1% SDS. Briefly, DNA was analyzed using spectrophotometry, electrophoresis and PCR. Results Results indicated that time spent in storage typically decreased the DNA quantity with the exception of protocol 1. The purity of DNA was generally not affected by storage times for the commercial based protocols, while the purity of the DNA samples extracted by the noncommercial protocols typically decreased when the saliva was stored longer. Only protocol 1 consistently extracted unfragmented DNA samples. In general, DNA samples extracted through protocols 1, 2, 3 and 4, regardless of storage time, were amplified by human specific primers whereas protocol 5 produced almost no samples that were able to be amplified by human specific primers. Depending on the protocol used, it was possible to extract DNA in high quantities and of good quality using whole saliva, and furthermore, for the purposes of DNA extraction, saliva can be reliably stored for relatively long time periods. Conclusions In summary, a complicated picture emerges when taking into account the extracted DNA’s quantity, purity and quality; depending on a given researchers needs, one protocol’s particular strengths and costs might be the deciding factor for its employment. PMID:28403355
Protocol for Detection of Yersinia pestis in Environmental ...
Methods Report This is the first ever open-access and detailed protocol available to all government departments and agencies, and their contractors to detect Yersinia pestis, the pathogen that causes plague, from multiple environmental sample types including water. Each analytical method includes sample processing procedure for each sample type in a step-by-step manner. It includes real-time PCR, traditional microbiological culture, and the Rapid Viability PCR (RV-PCR) analytical methods. For large volume water samples it also includes an ultra-filtration-based sample concentration procedure. Because of such a non-restrictive availability of this protocol to all government departments and agencies, and their contractors, the nation will now have increased laboratory capacity to analyze large number of samples during a wide-area plague incident.
Processing Protocol for Soil Samples Potentially ...
Method Operating Procedures This protocol describes the processing steps for 45 g and 9 g soil samples potentially contaminated with Bacillus anthracis spores. The protocol is designed to separate and concentrate the spores from bulk soil down to a pellet that can be used for further analysis. Soil extraction solution and mechanical shaking are used to disrupt soil particle aggregates and to aid in the separation of spores from soil particles. Soil samples are washed twice with soil extraction solution to maximize recovery. Differential centrifugation is used to separate spores from the majority of the soil material. The 45 g protocol has been demonstrated by two laboratories using both loamy and sandy soil types. There were no significant differences overall between the two laboratories for either soil type, suggesting that the processing protocol would be robust enough to use at multiple laboratories while achieving comparable recoveries. The 45 g protocol has demonstrated a matrix limit of detection at 14 spores/gram of soil for loamy and sandy soils.
Silvestri, Erin E.; Griffin, Dale W.
2017-01-01
This protocol describes the processing steps for 45 g and 9 g soil samples potentially contaminated with Bacillus anthracis spores. The protocol is designed to separate and concentrate the spores from bulk soil down to a pellet that can be used for further analysis. Soil extraction solution and mechanical shaking are used to disrupt soil particle aggregates and to aid in the separation of spores from soil particles. Soil samples are washed twice with soil extraction solution to maximize recovery. Differential centrifugation is used to separate spores from the majority of the soil material. The 45 g protocol has been demonstrated by two laboratories using both loamy and sandy soil types. There were no significant differences overall between the two laboratories for either soil type, suggesting that the processing protocol would be robust enough to use at multiple laboratories while achieving comparable recoveries. The 45 g protocol has demonstrated a matrix limit of detection at 14 spores/gram of soil for loamy and sandy soils.
Yi, Chih-Hsun; Lei, Wei-Yi; Hung, Jui-Sheng; Liu, Tso-Tsai; Chen, Chien-Lin; Pace, Fabio
2016-01-01
AIM To determine whether capsaicin infusion could influence heartburn perception and secondary peristalsis in patients with gastroesophageal reflux disease (GERD). METHODS Secondary peristalsis was performed with slow and rapid mid-esophageal injections of air in 10 patients with GERD. In a first protocol, saline and capsaicin-containing red pepper sauce infusions were randomly performed, whereas 2 consecutive sessions of capsaicin-containing red pepper sauce infusions were performed in a second protocol. Tested solutions including 5 mL of red pepper sauce diluted with 15 mL of saline and 20 mL of 0.9% saline were infused into the mid-esophagus via the manometric catheter at a rate of 10 mL/min with a randomized and double-blind fashion. During each study protocol, perception of heartburn, threshold volumes and peristaltic parameters for secondary peristalsis were analyzed and compared between different stimuli. RESULTS Infusion of capsaicin significantly increased heartburn perception in patients with GERD (P < 0.001), whereas repeated capsaicin infusion significantly reduced heartburn perception (P = 0.003). Acute capsaicin infusion decreased threshold volume of secondary peristalsis (P = 0.001) and increased its frequency (P = 0.01) during rapid air injection. The prevalence of GERD patients with successive secondary peristalsis during slow air injection significantly increased after capsaicin infusion (P = 0.001). Repeated capsaicin infusion increased threshold volume of secondary peristalsis (P = 0.002) and reduced the frequency of secondary peristalsis (P = 0.02) during rapid air injection. CONCLUSION Acute esophageal exposure to capsaicin enhances heartburn sensation and promotes secondary peristalsis in gastroesophageal reflux disease, but repetitive capsaicin infusion reverses these effects. PMID:28018112
A simplified protocol for molecular identification of Eimeria species in field samples.
Haug, Anita; Thebo, Per; Mattsson, Jens G
2007-05-15
This study aimed to find a fast, sensitive and efficient protocol for molecular identification of chicken Eimeria spp. in field samples. Various methods for each of the three steps of the protocol were evaluated: oocyst wall rupturing methods, DNA extraction methods, and identification of species-specific DNA sequences by PCR. We then compared and evaluated five complete protocols. Three series of oocyst suspensions of known number of oocysts from Eimeria mitis, Eimeria praecox, Eimeria maxima and Eimeria tenella were prepared and ground using glass beads or mini-pestle. DNA was extracted from ruptured oocysts using commercial systems (GeneReleaser, Qiagen Stoolkit and Prepman) or phenol-chloroform DNA extraction, followed by identification of species-specific ITS-1 sequences by optimised single species PCR assays. The Stoolkit and Prepman protocols showed insufficient repeatability, and the former was also expensive and relatively time-consuming. In contrast, both the GeneReleaser protocol and phenol-chloroform protocols were robust and sensitive, detecting less than 0.4 oocysts of each species per PCR. Finally, we evaluated our new protocol on 68 coccidia positive field samples. Our data suggests that rupturing the oocysts by mini-pestle grinding, preparing the DNA with GeneReleaser, followed by optimised single species PCR assays, makes a robust and sensitive procedure for identifying chicken Eimeria species in field samples. Importantly, it also provides minimal hands-on-time in the pre-PCR process, lower contamination risk and no handling of toxic chemicals.
Lewandowska, Dagmara W; Zagordi, Osvaldo; Geissberger, Fabienne-Desirée; Kufner, Verena; Schmutz, Stefan; Böni, Jürg; Metzner, Karin J; Trkola, Alexandra; Huber, Michael
2017-08-08
Sequence-specific PCR is the most common approach for virus identification in diagnostic laboratories. However, as specific PCR only detects pre-defined targets, novel virus strains or viruses not included in routine test panels will be missed. Recently, advances in high-throughput sequencing allow for virus-sequence-independent identification of entire virus populations in clinical samples, yet standardized protocols are needed to allow broad application in clinical diagnostics. Here, we describe a comprehensive sample preparation protocol for high-throughput metagenomic virus sequencing using random amplification of total nucleic acids from clinical samples. In order to optimize metagenomic sequencing for application in virus diagnostics, we tested different enrichment and amplification procedures on plasma samples spiked with RNA and DNA viruses. A protocol including filtration, nuclease digestion, and random amplification of RNA and DNA in separate reactions provided the best results, allowing reliable recovery of viral genomes and a good correlation of the relative number of sequencing reads with the virus input. We further validated our method by sequencing a multiplexed viral pathogen reagent containing a range of human viruses from different virus families. Our method proved successful in detecting the majority of the included viruses with high read numbers and compared well to other protocols in the field validated against the same reference reagent. Our sequencing protocol does work not only with plasma but also with other clinical samples such as urine and throat swabs. The workflow for virus metagenomic sequencing that we established proved successful in detecting a variety of viruses in different clinical samples. Our protocol supplements existing virus-specific detection strategies providing opportunities to identify atypical and novel viruses commonly not accounted for in routine diagnostic panels.
Beelen, Rob; Raaschou-Nielsen, Ole; Stafoggia, Massimo; Andersen, Zorana Jovanovic; Weinmayr, Gudrun; Hoffmann, Barbara; Wolf, Kathrin; Samoli, Evangelia; Fischer, Paul; Nieuwenhuijsen, Mark; Vineis, Paolo; Xun, Wei W; Katsouyanni, Klea; Dimakopoulou, Konstantina; Oudin, Anna; Forsberg, Bertil; Modig, Lars; Havulinna, Aki S; Lanki, Timo; Turunen, Anu; Oftedal, Bente; Nystad, Wenche; Nafstad, Per; De Faire, Ulf; Pedersen, Nancy L; Östenson, Claes-Göran; Fratiglioni, Laura; Penell, Johanna; Korek, Michal; Pershagen, Göran; Eriksen, Kirsten Thorup; Overvad, Kim; Ellermann, Thomas; Eeftens, Marloes; Peeters, Petra H; Meliefste, Kees; Wang, Meng; Bueno-de-Mesquita, Bas; Sugiri, Dorothea; Krämer, Ursula; Heinrich, Joachim; de Hoogh, Kees; Key, Timothy; Peters, Annette; Hampel, Regina; Concin, Hans; Nagel, Gabriele; Ineichen, Alex; Schaffner, Emmanuel; Probst-Hensch, Nicole; Künzli, Nino; Schindler, Christian; Schikowski, Tamara; Adam, Martin; Phuleria, Harish; Vilier, Alice; Clavel-Chapelon, Françoise; Declercq, Christophe; Grioni, Sara; Krogh, Vittorio; Tsai, Ming-Yi; Ricceri, Fulvio; Sacerdote, Carlotta; Galassi, Claudia; Migliore, Enrica; Ranzi, Andrea; Cesaroni, Giulia; Badaloni, Chiara; Forastiere, Francesco; Tamayo, Ibon; Amiano, Pilar; Dorronsoro, Miren; Katsoulis, Michail; Trichopoulou, Antonia; Brunekreef, Bert; Hoek, Gerard
2014-03-01
Few studies on long-term exposure to air pollution and mortality have been reported from Europe. Within the multicentre European Study of Cohorts for Air Pollution Effects (ESCAPE), we aimed to investigate the association between natural-cause mortality and long-term exposure to several air pollutants. We used data from 22 European cohort studies, which created a total study population of 367,251 participants. All cohorts were general population samples, although some were restricted to one sex only. With a strictly standardised protocol, we assessed residential exposure to air pollutants as annual average concentrations of particulate matter (PM) with diameters of less than 2.5 μm (PM2.5), less than 10 μm (PM10), and between 10 μm and 2.5 μm (PMcoarse), PM2.5 absorbance, and annual average concentrations of nitrogen oxides (NO2 and NOx), with land use regression models. We also investigated two traffic intensity variables-traffic intensity on the nearest road (vehicles per day) and total traffic load on all major roads within a 100 m buffer. We did cohort-specific statistical analyses using confounder models with increasing adjustment for confounder variables, and Cox proportional hazards models with a common protocol. We obtained pooled effect estimates through a random-effects meta-analysis. The total study population consisted of 367,251 participants who contributed 5,118,039 person-years at risk (average follow-up 13.9 years), of whom 29,076 died from a natural cause during follow-up. A significantly increased hazard ratio (HR) for PM2.5 of 1.07 (95% CI 1.02-1.13) per 5 μg/m(3) was recorded. No heterogeneity was noted between individual cohort effect estimates (I(2) p value=0.95). HRs for PM2.5 remained significantly raised even when we included only participants exposed to pollutant concentrations lower than the European annual mean limit value of 25 μg/m(3) (HR 1.06, 95% CI 1.00-1.12) or below 20 μg/m(3) (1.07, 1.01-1.13). Long-term exposure to fine particulate air pollution was associated with natural-cause mortality, even within concentration ranges well below the present European annual mean limit value. European Community's Seventh Framework Program (FP7/2007-2011). Copyright © 2014 Elsevier Ltd. All rights reserved.
A MORE COST-EFFECTIVE EMAP-ESTUARIES BENTHIC MACROFAUNAL SAMPLING PROTOCOL
The standard benthic macrofaunal sampling protocol in the U.S. Environmental Protection Agency's Pacific Coast Environmental Monitoring and Assessment Program (EMAP) is to collect a minimum of 30 random benthic samples per reporting unit (e.g., estuary) using a 0.1 m2 grab and to...
It's Time to Develop a New "Draft Test Protocol" for a Mars Sample Return Mission (or Two....)
NASA Astrophysics Data System (ADS)
Rummel, J. D.
2018-04-01
A Mars Sample Return (MSR) will involve analysis of those samples in containment, including their safe receiving, handling, testing, and archiving. With an MSR planned for the end of the next decade, it is time to update the existing MSR protocol.
Gentle, A R; Smith, G B
2014-10-20
Accurate solar and visual transmittances of materials in which surfaces or internal structures are complex are often not easily amenable to standard procedures with laboratory-based spectrophotometers and integrating spheres. Localized "hot spots" of intensity are common in such materials, so data on small samples is unreliable. A novel device and simple protocols have been developed and undergone validation testing. Simultaneous solar and visible transmittance and reflectance data have been acquired for skylight components and multilayer polycarbonate roof panels. The pyranometer and lux sensor setups also directly yield "light coolness" in lumens/watt. Sample areas must be large, and, although mainly in sheet form, some testing has been done on curved panels. The instrument, its operation, and the simple calculations used are described. Results on a subset of diffuse and partially diffuse materials with no hot spots have been cross checked using 150 mm integrating spheres with a spectrophotometer and the Air Mass 1.5 spectrum. Indications are that results are as good or better than with such spheres for transmittance, but reflectance techniques need refinement for some sample types.
Phase 1 Free Air CO2 Enrichment Model-Data Synthesis (FACE-MDS): Model Output Data (2015)
Walker, A. P.; De Kauwe, M. G.; Medlyn, B. E.; Zaehle, S.; Asao, S.; Dietze, M.; El-Masri, B.; Hanson, P. J.; Hickler, T.; Jain, A.; Luo, Y.; Parton, W. J.; Prentice, I. C.; Ricciuto, D. M.; Thornton, P. E.; Wang, S.; Wang, Y -P; Warlind, D.; Weng, E.; Oren, R.; Norby, R. J.
2015-01-01
These datasets comprise the model output from phase 1 of the FACE-MDS. These include simulations of the Duke and Oak Ridge experiments and also idealised long-term (300 year) simulations at both sites (please see the modelling protocol for details). Included as part of this dataset are modelling and output protocols. The model datasets are formatted according to the output protocols. Phase 1 datasets are reproduced here for posterity and reproducibility although the model output for the experimental period have been somewhat superseded by the Phase 2 datasets.
Airborne fibre and asbestos concentrations in system built schools
NASA Astrophysics Data System (ADS)
Burdett, Garry; Cottrell, Steve; Taylor, Catherine
2009-02-01
This paper summarises the airborne fibre concentration data measured in system built schools that contained asbestos insulation board (AIB) enclosed in the support columns by a protective steel casing. The particular focus of this work was the CLASP (Consortium of Local Authorities Special Programme) system buildings. A variety of air monitoring tests were carried out to assess the potential for fibres to be released into the classroom. A peak release testing protocol was adopted that involved static sampling, while simulating direct impact disturbances to selected columns. This was carried out before remediation, after sealing gaps and holes in and around the casing visible in the room (i.e. below ceiling level) and additionally round the tops of the columns, which extended into the suspended ceiling void. Simulated and actual measurements of worker exposures were also undertaken, while sealing columns, carrying out cleaning and maintenance work in the ceiling voids. Routine analysis of these air samples was carried out by phase contrast microscopy (PCM) with a limited amount of analytical transmission electron microscopy (TEM) analysis to confirm whether the fibres visible by PCM were asbestos or non-asbestos. The PCM fibre concentrations data from the peak release tests showed that while direct releases of fibres to the room air can occur from gaps and holes in and around the column casings, sealing is an effective way of minimising releases to below the limit of quantification (0.01 f/ml) of the PCM method for some 95% of the tests carried out. Sealing with silicone filler and taping any gaps and seams visible on the column casing in the room, also gave concentrations below the limit of quantification (LOQ) of the PCM method for 95% of the tests carried out. The data available did not show any significant difference between the PCM fibre concentrations in the room air for columns that had or had not been sealed in the ceiling void, as well as in the room. Occupant exposures during normal classroom teaching activities in areas that had undergone remediation were also monitored with much greater use of TEM analysis to determine the asbestos fibre concentration. No asbestos fibres were found in the TEM analysis of samples of classroom air from seven schools, after remediation had taken place. Occupant exposures in one school and one office building have been monitored before remediation and only one asbestos fibre was found in each set of samples analysed. The average monitored occupant exposures to asbestos in CLASP buildings was <0.00005 f/ml, an order of magnitude lower than previous measurements in UK buildings.
Improving Leishmania Species Identification in Different Types of Samples from Cutaneous Lesions
Cruz-Barrera, Mónica L.; Ovalle-Bracho, Clemencia; Ortegon-Vergara, Viviana; Pérez-Franco, Jairo E.
2015-01-01
The discrimination of Leishmania species from patient samples has epidemiological and clinical relevance. In this study, different gene target PCR-restriction fragment length polymorphism (RFLP) protocols were evaluated for their robustness as Leishmania species discriminators in 61 patients with cutaneous leishmaniasis. We modified the hsp70-PCR-RFLP protocol and found it to be the most reliable protocol for species identification. PMID:25609727
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Optional SO2 Emissions Data Protocol for Gas-Fired and Oil-Fired Units D Appendix D to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. D Appendix D to Part 75—Optional SO2 Emissions Data...
Multimedia-Based Integration of Cross-Layer Techniques
2014-06-01
wireless networks play a critical role in net-centric warfare, including the sharing of the time-sensitive battlefield information among military nodes for...layer protocols are key enablers in effectively deploying the military wireless network. This report discusses the design of cross-layer protocols...2 1.0 INTRODUCTION 1.1 Motivation The Air Force (AF) Wireless Networks (also denoted as military networks in this report) must be capable of
Aboal, J R; Boquete, M T; Carballeira, A; Casanova, A; Debén, S; Fernández, J A
2017-05-01
In this study we examined 6080 data gathered by our research group during more than 20 years of research on the moss biomonitoring technique, in order to quantify the variability generated by different aspects of the protocol and to calculate the overall measurement uncertainty associated with the technique. The median variance of the concentrations of different pollutants measured in moss tissues attributed to the different methodological aspects was high, reaching values of 2851 (ng·g -1 ) 2 for Cd (sample treatment), 35.1 (μg·g -1 ) 2 for Cu (sample treatment), 861.7 (ng·g -1 ) 2 and for Hg (material selection). These variances correspond to standard deviations that constitute 67, 126 and 59% the regional background levels of these elements in the study region. The overall measurement uncertainty associated with the worst experimental protocol (5 subsamples, refrigerated, washed, 5 × 5 m size of the sampling area and once a year sampling) was between 2 and 6 times higher than that associated with the optimal protocol (30 subsamples, dried, unwashed, 20 × 20 m size of the sampling area and once a week sampling), and between 1.5 and 7 times higher than that associated with the standardized protocol (30 subsamples and once a year sampling). The overall measurement uncertainty associated with the standardized protocol could generate variations of between 14 and 47% in the regional background levels of Cd, Cu, Hg, Pb and Zn in the study area and much higher levels of variation in polluted sampling sites. We demonstrated that although the overall measurement uncertainty of the technique is still high, it can be reduced by using already well defined aspects of the protocol. Further standardization of the protocol together with application of the information on the overall measurement uncertainty would improve the reliability and comparability of the results of different biomonitoring studies, thus extending use of the technique beyond the context of scientific research. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Srisitthiratkul, Chutima; Pongsorrarith, Voraluck; Intasanta, Narupol
2011-08-01
While chemical and biological attacks pose risk to human health, clean air is of scientific, environmental and physiological concerns. In the present contribution, the potential use of nanosilver-decorated titanium dioxide (TiO 2) nanofibers for toxin decomposition with antimicrobial activity and self-cleaning properties was investigated. Titanium dioxide nanofibers were prepared through sol-gel reaction followed by an electrospinning process. Following the Japan Industrial Standard (JIS) protocol, decompositions of nitrogen oxide (NOx) and volatile organic compound (VOC) by the TiO 2 nanofibers suggested that these materials were capable of air treatment. To further enhance their anti-microbial activity, silver nanoparticles were decorated onto the TiO 2 nanofibers' surfaces via photoreduction of silver ion in the presence of the nanofibers suspension. Furthermore, tests of photocatalytic activity of the samples were performed by photodegrading methylene blue in water. The nanofibrous membranes prepared from these nanofibers showed superhydrophilicity under UV. Finally, the possibility of using these hybrid nanofibers in environmental and hygienic nanofiltration was proposed, where the self-cleaning characteristics was expected to be valuable in maintenance processes.
Calibrated work function mapping by Kelvin probe force microscopy
NASA Astrophysics Data System (ADS)
Fernández Garrillo, Pablo A.; Grévin, Benjamin; Chevalier, Nicolas; Borowik, Łukasz
2018-04-01
We propose and demonstrate the implementation of an alternative work function tip calibration procedure for Kelvin probe force microscopy under ultrahigh vacuum, using monocrystalline metallic materials with known crystallographic orientation as reference samples, instead of the often used highly oriented pyrolytic graphite calibration sample. The implementation of this protocol allows the acquisition of absolute and reproducible work function values, with an improved uncertainty with respect to unprepared highly oriented pyrolytic graphite-based protocols. The developed protocol allows the local investigation of absolute work function values over nanostructured samples and can be implemented in electronic structures and devices characterization as demonstrated over a nanostructured semiconductor sample presenting Al0.7Ga0.3As and GaAs layers with variable thickness. Additionally, using our protocol we find that the work function of annealed highly oriented pyrolytic graphite is equal to 4.6 ± 0.03 eV.
Changes in Breath Trihalomethane Levels Resulting from Household Water-Use Activities
Gordon, Sydney M.; Brinkman, Marielle C.; Ashley, David L.; Blount, Benjamin C.; Lyu, Christopher; Masters, John; Singer, Philip C.
2006-01-01
Common household water-use activities such as showering, bathing, drinking, and washing clothes or dishes are potentially important contributors to individual exposure to trihalomethanes (THMs), the major class of disinfection by-products of water treated with chlorine. Previous studies have focused on showering or bathing activities. In this study, we selected 12 common water-use activities and determined which may lead to the greatest THM exposures and result in the greatest increase in the internal dose. Seven subjects performed the various water-use activities in two residences served by water utilities with relatively high and moderate total THM levels. To maintain a consistent exposure environment, the activities, exposure times, air exchange rates, water flows, water temperatures, and extraneous THM emissions to the indoor air were carefully controlled. Water, indoor air, blood, and exhaled-breath samples were collected during each exposure session for each activity, in accordance with a strict, well-defined protocol. Although showering (for 10 min) and bathing (for 14 min), as well as machine washing of clothes and opening mechanical dishwashers at the end of the cycle, resulted in substantial increases in indoor air chloroform concentrations, only showering and bathing caused significant increases in the breath chloroform levels. In the case of bromodichloromethane (BDCM), only bathing yielded a significantly higher air level in relation to the preexposure concentration. For chloroform from showering, strong correlations were observed for indoor air and exhaled breath, blood and exhaled breath, indoor air and blood, and tap water and blood. Only water and breath, and blood and breath were significantly associated for chloroform from bathing. For BDCM, significant correlations were obtained for blood and air, and blood and water from showering. Neither dibromochloromethane nor bromoform gave measurable breath concentrations for any of the activities investigated because of their much lower tap-water concentrations. Future studies will address the effects that changes in these common water-use activities may have on exposure. PMID:16581538
Evaluation of microbiological air quality and of microclimate in university classrooms.
Grisoli, Pietro; Rodolfi, Marinella; Chiara, Tiziana; Zonta, Laura Attinia; Dacarro, Cesare
2012-07-01
The proliferation of air-diffused microorganisms inside public buildings such as schools, hospitals, and universities, is often indicated as a possible health risk. In this research, we have illustrated the results of an investigation realized to determine the health of the air in some university classrooms, both from a microbiological and a microclimatic viewpoint, during the normal didactic activity of direct lessons. The results obtained have been expressed by means of contamination indices, already used in previous works. Very little contamination was recorded in the different phases of air treatment, which underlines the efficiency of the system and of the maintenance protocols. The Global Index of Microbial Contamination (GIMC per cubic meter) showed a value greater than the mean during the heating period (290), while the highest values (95th percentile 1,138.45) were recorded in the period using air conditioning. The index of mesophilic bacterial contamination, though it did not show any significant differences in the various modes of air treatment, showed a mean value (1.34) and the 95th percentile value (4.14), which was greater in the air-conditioning phase. Finally, the mean value of the amplification index underlined a decrease in the microbial contamination in comparison to the outside, while showing situations of increased microbial amplification during the period of simple ventilation (95th percentile 4.27). The 95th percentile values found for GICM in the three sampling periods, however, permitted us to identify the value of GIMC per cubic meter equal to 1,000 as a guide to provide a means of self-monitoring the quality of the air inside the classrooms. From a microclimatic viewpoint, two periods of the year manifested discomfort situations: during the heating phase (winter) and during the simple ventilation phase (spring). The results obtained indicate, therefore, a need to intervene on the environmental parameters, not being able, in this particular case, to intervene on other aspects that influence the microclimate.
The purpose of this project was to investigate the effectiveness of the sample preservation protocol outlined in Method 200.8 in recovering lead from water samples. Lead recoveries were studied in various water samples spiked with lead by evaluating lead sorption and desorption f...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Samples and protocols. 660.36 Section 660.36 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS... Research Sample Custodian (ATTN: HFM-672) (see mailing addresses in § 600.2 of this chapter), within 30...
BIASES IN CASTNET FILTER PACK RESULTS ASSOCIATED WITH SAMPLING PROTOCOL
In the current study, single filter weekly (w) results are compared with weekly results aggregated from day and night (dn) weekly samples. Comparisons of the two sampling protocols for all major constituents (SO42-, NO3-, NH4+, HNO3, and SO2) show median bias (MB) of < 5 nmol m-3...
Souza, Rodrigo O A; Valandro, Luiz F; Melo, Renata M; Machado, João P B; Bottino, Marco A; Ozcan, Mutlu
2013-10-01
This study evaluated the effect of different air-particle abrasion protocols on the biaxial flexural strength and structural stability of zirconia ceramics. Zirconia ceramic specimens (ISO 6872) (Lava, 3M ESPE) were obtained (N=336). The specimens (N=118, n=20 per group) were randomly assigned to one of the air-abrasion protocols: Gr1: Control (as-sintered); Gr2: 50 µm Al2O3 (2.5 bar); Gr3: 50 µm Al2O3 (3.5 bar); Gr4: 110 µm Al2O3(2.5 bar); Gr5: 110 µm Al2O3 (3.5 bar); Gr6: 30 µm SiO2 (2.5 bar) (CoJet); Gr7: 30 µm SiO2(3.5 bar); Gr8: 110 µm SiO2 (2.5 bar) (Rocatec Plus); and Gr9: 110 µm SiO2 (3.5 bar) (duration: 20 s, distance: 10 mm). While half of the specimens were tested immediately, the other half was subjected to cyclic loading in water (100,000 cycles; 50 N, 4 Hz, 37 °°C) prior to biaxial flexural strength test (ISO 6872). Phase transformation (t→m), relative amount of transformed monoclinic zirconia (FM), transformed zone depth (TZD) and surface roughness were measured. Particle type (p=0.2746), pressure (p=0.5084) and cyclic loading (p=0.1610) did not influence the flexural strength. Except for the air-abraded group with 110 µm Al2O3 at 3.5 bar, all air-abrasion protocols increased the biaxial flexural strength (MPa) (Controlnon-aged: 1,030 ± 153, Controlaged: 1,138 ± 138; Experimentalnon-aged: 1,307 ± 184-1,554 ± 124; Experimentalaged: 1,308 ± 118-1,451 ± 135) in both non-aged and aged conditions, respectively. Surface roughness (Ra) was the highest with 110 µm Al2O3(0.84 µm. FM values ranged from 0% to 27.21%, higher value for the Rocatec Plus (110 µm SiO2) and 110 µm Al2O3 groups at 3.5 bar pressure. TZD ranged between 0 and 1.43 µm, with the highest values for Rocatec Plus and 110 µm Al2O3 groups at 3.5 bar pressure. Copyright © 2013 Elsevier Ltd. All rights reserved.
Microbiological contamination of compressed air used in dentistry: an investigation.
Conte, M; Lynch, R M; Robson, M G
2001-11-01
The purpose of this preliminary investigation was twofold: 1) to examine the possibility of cross-contamination between a dental-evacuation system and the compressed air used in dental operatories and 2) to capture and identify the most common microflora in the compressed-air supply. The investigation used swab, water, and air sampling that was designed to track microorganisms from the evacuation system, through the air of the mechanical room, into the compressed-air system, and back to the patient. Samples taken in the vacuum system, the air space in the mechanical room, and the compressed-air storage tank had significantly higher total concentrations of bacteria than the outside air sampled. Samples of the compressed air returning to the operatory were found to match the outside air sample in total bacteria. It was concluded that the air dryer may have played a significant role in the elimination of microorganisms from the dental compressed-air supply.
Copper(I)/TEMPO Catalyzed Aerobic Oxidation of Primary Alcohols to Aldehydes with Ambient Air
Hoover, Jessica M.; Steves, Janelle E.; Stahl, Shannon S.
2012-01-01
This protocol describes a practical laboratory-scale method for aerobic oxidation of primary alcohols to aldehydes, using a chemoselective CuI/TEMPO catalyst system. The catalyst is prepared in situ from commercially available reagents, and the reactions are performed in a common organic solvent (acetonitrile) with ambient air as the oxidant. Three different reaction conditions and three procedures for the isolation and purification of the aldehyde product are presented. The oxidations of eight different alcohols, described here, include representative examples of each reaction condition and purification method. Reaction times vary from 20 min to 24 h, depending on the alcohol, while the purification methods each take about 2 h. The total time necessary for the complete protocol ranges from 3 – 26 h. PMID:22635108
The Aeronautical Data Link: Taxonomy, Architectural Analysis, and Optimization
NASA Technical Reports Server (NTRS)
Morris, A. Terry; Goode, Plesent W.
2002-01-01
The future Communication, Navigation, and Surveillance/Air Traffic Management (CNS/ATM) System will rely on global satellite navigation, and ground-based and satellite based communications via Multi-Protocol Networks (e.g. combined Aeronautical Telecommunications Network (ATN)/Internet Protocol (IP)) to bring about needed improvements in efficiency and safety of operations to meet increasing levels of air traffic. This paper will discuss the development of an approach that completely describes optimal data link architecture configuration and behavior to meet the multiple conflicting objectives of concurrent and different operations functions. The practical application of the approach enables the design and assessment of configurations relative to airspace operations phases. The approach includes a formal taxonomic classification, an architectural analysis methodology, and optimization techniques. The formal taxonomic classification provides a multidimensional correlation of data link performance with data link service, information protocol, spectrum, and technology mode; and to flight operations phase and environment. The architectural analysis methodology assesses the impact of a specific architecture configuration and behavior on the local ATM system performance. Deterministic and stochastic optimization techniques maximize architectural design effectiveness while addressing operational, technology, and policy constraints.
Diagnosing AIRS Sampling with CloudSat Cloud Classes
NASA Technical Reports Server (NTRS)
Fetzer, Eric; Yue, Qing; Guillaume, Alexandre; Kahn, Brian
2011-01-01
AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.
Space flight operations communications phraseology and techniques
NASA Technical Reports Server (NTRS)
Noneman, S. R.
1986-01-01
Communications are a critical link in space flight operations. Specific communications phraseology and techniques have been developed to allow rapid and clear transfer of information. Communications will be clear and brief through the use of procedural words and phrases. Communications protocols standardize the required information transferred. The voicing of letters and numbers is discussed. The protocols used in air-to-ground communications are given. A glossary of communications terminology is presented in the appendix.
Coelho, Lúcia H G; Melchert, Wanessa R; Rocha, Flavio R; Rocha, Fábio R P; Gutz, Ivano G R
2010-11-15
The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the μg m(-3) range) and their variations with sampling site and time. In this work, a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE), a quick separation technique that requires nothing more than some nanoliters of sample and, when combined with capacitively coupled contactless conductometric detection (C(4)D), is particularly favorable for ionic species that do not absorb in the UV-vis region, like the target analytes formaldehyde, formic acid, acetic acid and ammonium. The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry's constant such as formaldehyde and carboxylic acids, or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8.3 nL s(-1)), while the sample was aspirated through the annular gap of the concentric tubes at 2.5 mL s(-1). A second unit, in all similar to the CMDS, was operated as a capillary membrane diffusion emitter (CMDE), generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS. The fluids of the system were driven with inexpensive aquarium air pumps, and the collected samples were stored in vials cooled by a Peltier element. Complete protocols were developed for the analysis, in air, of NH(3), CH(3)COOH, HCOOH and, with a derivatization setup, CH(2)O, by associating the CMDS collection with the determination by CE-C(4)D. The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot's reaction. Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction, solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW). All techniques and methods of this work are in line with the green analytical chemistry trends. Copyright © 2010 Elsevier B.V. All rights reserved.
Mitra, Abhishek; Skrzypczak, Magdalena; Ginalski, Krzysztof; Rowicka, Maga
2015-01-01
Sequencing microRNA, reduced representation sequencing, Hi-C technology and any method requiring the use of in-house barcodes result in sequencing libraries with low initial sequence diversity. Sequencing such data on the Illumina platform typically produces low quality data due to the limitations of the Illumina cluster calling algorithm. Moreover, even in the case of diverse samples, these limitations are causing substantial inaccuracies in multiplexed sample assignment (sample bleeding). Such inaccuracies are unacceptable in clinical applications, and in some other fields (e.g. detection of rare variants). Here, we discuss how both problems with quality of low-diversity samples and sample bleeding are caused by incorrect detection of clusters on the flowcell during initial sequencing cycles. We propose simple software modifications (Long Template Protocol) that overcome this problem. We present experimental results showing that our Long Template Protocol remarkably increases data quality for low diversity samples, as compared with the standard analysis protocol; it also substantially reduces sample bleeding for all samples. For comprehensiveness, we also discuss and compare experimental results from alternative approaches to sequencing low diversity samples. First, we discuss how the low diversity problem, if caused by barcodes, can be avoided altogether at the barcode design stage. Second and third, we present modified guidelines, which are more stringent than the manufacturer’s, for mixing low diversity samples with diverse samples and lowering cluster density, which in our experience consistently produces high quality data from low diversity samples. Fourth and fifth, we present rescue strategies that can be applied when sequencing results in low quality data and when there is no more biological material available. In such cases, we propose that the flowcell be re-hybridized and sequenced again using our Long Template Protocol. Alternatively, we discuss how analysis can be repeated from saved sequencing images using the Long Template Protocol to increase accuracy. PMID:25860802
Biobriefcase aerosol collector
Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA
2009-09-22
A system for sampling air and collecting particles entrained in the air that potentially include bioagents. The system comprises providing a receiving surface, directing a liquid to the receiving surface and producing a liquid surface. Collecting samples of the air and directing the samples of air so that the samples of air with particles entrained in the air impact the liquid surface. The particles potentially including bioagents become captured in the liquid. The air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid but cause minor turbulence. The liquid surface has a surface tension and the collector samples the air and directs the air to the liquid surface so that the air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid, but cause minor turbulence on the surface resulting in insignificant evaporation of the liquid.
Development and testing of a portable wind sensitive directional air sampler
NASA Technical Reports Server (NTRS)
Deyo, J.; Toma, J.; King, R. B.
1975-01-01
A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.
NASA Astrophysics Data System (ADS)
Mancini, S.; Caliendo, E.; Guida, M.; Bisceglia, B.
2017-10-01
The main purpose of the work described in this paper has been to establish the protocol for a new non-disruptive technique of intervention, based on microwave treatment, for cleaning operations on monumental historical buildings, to eliminate biodeteriogens infesting stones. Non-destructive methods in the cleaning operations, should not only preserve the physical integrity, the chemical-mineralogical and structural identity of materials, but, when the exhalation of pollutant agents (like for example Radon gas) from building materials is considered, also, make the indoor air quality (IAQ) levels healthy. Therefore, one of the main steps of the protocol proposed in this paper is concerned with the assessment of the Radon exhalation rate in order to verify that microwave treatments do not increase the Radon naturally exhalated by building materials. In this paper, the preliminary results of the Radon measurements performed on two different type of tuff samples (grey tuff and yellow tuff), typical of the Italian traditional construction heritage, with the E-PERM passive technique at the Environmental Radioactivity Laboratory (Amb.Ra.), University of Salerno, Italy, ISO 9001:2008 certified, are summarized.
Section 608 Technician Certification Test Topics
Identifies some of the topics covered on Section 608 Technician Certification tests such as ozone depletion, the Clean Air Act and Montreal Protocol, Substitute Refrigerants and oils, Refrigeration and Recovery Techniques.
Effect of Drying on Heavy Metal Fraction Distribution in Rice Paddy Soil
Qi, Yanbing; Huang, Biao; Darilek, Jeremy Landon
2014-01-01
An understanding of how redox conditions affect soil heavy metal fractions in rice paddies is important due to its implications for heavy metal mobility and plant uptake. Rice paddy soil samples routinely undergo oxidation prior to heavy metal analysis. Fraction distribution of Cu, Pb, Ni, and Cd from paddy soil with a wide pH range was investigated. Samples were both dried according to standard protocols and also preserved under anaerobic conditions through the sampling and analysis process and heavy metals were then sequentially extracted for the exchangeable and carbonate bound fraction (acid soluble fraction), iron and manganese oxide bound fraction (reducible fraction), organic bound fraction (oxidizable fraction), and residual fraction. Fractions were affected by redox conditions across all pH ranges. Drying decreased reducible fraction of all heavy metals. Curesidual fraction, Pboxidizable fraction, Cdresidual fraction, and Niresidual fraction increased by 25%, 33%, 35%, and >60%, respectively. Pbresidual fraction, Niacid soluble fraction, and Cdoxidizable fraction decreased 33%, 25%, and 15%, respectively. Drying paddy soil prior to heavy metal analysis overestimated Pb and underestimated Cu, Ni, and Cd. In future studies, samples should be stored after injecting N2 gas to maintain the redox potential of soil prior to heavy metal analysis, and investigate the correlation between heavy metal fraction distribution under field conditions and air-dried samples. PMID:24823670
Oyana, Tonny J.; Lomnicki, Slawomir M.; Guo, Chuqi; Cormier, Stephania A.
2018-01-01
Stable, bioreactive, radicals known as environmentally persistent free radicals (EPFRs) have been found to exist on the surface of airborne PM2.5. These EPFRs have been found to form during many combustion processes, are present in vehicular exhaust, and persist in the environment for weeks and biological systems for up to 12 h. To measure EPFRs in PM samples, high volume samplers are required and measurements are less representative of community exposure; therefore, we developed a novel spatial phytosampling methodology to study the spatial patterns of EPFR concentrations using plants. Leaf samples for laboratory PM analysis were collected from 188 randomly drawn sampling sites within a 500-m buffer zone of pollution sources across a sampling grid measuring 32.9 × 28.4 km in Memphis, Tennessee. PM was isolated from the intact leaves and size fractionated, and EPFRs on PM quantified by electron paramagnetic resonance spectroscopy. The radical concentration was found to positively correlate with the EPFR g-value, thus indicating cumulative content of oxygen centered radicals in PM with higher EPFR load. Our spatial phytosampling approach reveals spatial variations and potential “hotspots” risk due to EPFR exposure across Memphis and provides valuable insights for identifying exposure and demographic differences for health studies. PMID:28805054
Oyana, Tonny J; Lomnicki, Slawomir M; Guo, Chuqi; Cormier, Stephania A
2017-09-19
Stable, bioreactive, radicals known as environmentally persistent free radicals (EPFRs) have been found to exist on the surface of airborne PM 2.5 . These EPFRs have been found to form during many combustion processes, are present in vehicular exhaust, and persist in the environment for weeks and biological systems for up to 12 h. To measure EPFRs in PM samples, high volume samplers are required and measurements are less representative of community exposure; therefore, we developed a novel spatial phytosampling methodology to study the spatial patterns of EPFR concentrations using plants. Leaf samples for laboratory PM analysis were collected from 188 randomly drawn sampling sites within a 500-m buffer zone of pollution sources across a sampling grid measuring 32.9 × 28.4 km in Memphis, Tennessee. PM was isolated from the intact leaves and size fractionated, and EPFRs on PM quantified by electron paramagnetic resonance spectroscopy. The radical concentration was found to positively correlate with the EPFR g-value, thus indicating cumulative content of oxygen centered radicals in PM with higher EPFR load. Our spatial phytosampling approach reveals spatial variations and potential "hotspots" risk due to EPFR exposure across Memphis and provides valuable insights for identifying exposure and demographic differences for health studies.
NASA Astrophysics Data System (ADS)
Basak, Jyotirmoy; Maitra, Subhamoy
2018-04-01
In device-independent (DI) paradigm, the trustful assumptions over the devices are removed and CHSH test is performed to check the functionality of the devices toward certifying the security of the protocol. The existing DI protocols consider infinite number of samples from theoretical point of view, though this is not practically implementable. For finite sample analysis of the existing DI protocols, we may also consider strategies for checking device independence other than the CHSH test. In this direction, here we present a comparative analysis between CHSH and three-party Pseudo-telepathy game for the quantum private query protocol in DI paradigm that appeared in Maitra et al. (Phys Rev A 95:042344, 2017) very recently.
Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of thesemore » materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.« less
Waters, Ryan A.; Fowler, Veronica L.; Armson, Bryony; Nelson, Noel; Gloster, John; Paton, David J.; King, Donald P.
2014-01-01
Rapid, field-based diagnostic assays are desirable tools for the control of foot-and-mouth disease (FMD). Current approaches involve either; 1) Detection of FMD virus (FMDV) with immuochromatographic antigen lateral flow devices (LFD), which have relatively low analytical sensitivity, or 2) portable RT-qPCR that has high analytical sensitivity but is expensive. Loop-mediated isothermal amplification (LAMP) may provide a platform upon which to develop field based assays without these drawbacks. The objective of this study was to modify an FMDV-specific reverse transcription–LAMP (RT-LAMP) assay to enable detection of dual-labelled LAMP products with an LFD, and to evaluate simple sample processing protocols without nucleic acid extraction. The limit of detection of this assay was demonstrated to be equivalent to that of a laboratory based real-time RT-qPCR assay and to have a 10,000 fold higher analytical sensitivity than the FMDV-specific antigen LFD currently used in the field. Importantly, this study demonstrated that FMDV RNA could be detected from epithelial suspensions without the need for prior RNA extraction, utilising a rudimentary heat source for amplification. Once optimised, this RT-LAMP-LFD protocol was able to detect multiple serotypes from field epithelial samples, in addition to detecting FMDV in the air surrounding infected cattle, pigs and sheep, including pre-clinical detection. This study describes the development and evaluation of an assay format, which may be used as a future basis for rapid and low cost detection of FMDV. In addition it provides providing “proof of concept” for the future use of LAMP assays to tackle other challenging diagnostic scenarios encompassing veterinary and human health. PMID:25165973
Robotic Laser Coating Removal System
2008-07-01
Materiel Command IRR Internal Rate of Return JTP Joint Test Protocol JTR Joint Test Report LARPS Large Area Robotic Paint Stripping LASER Light...use of laser paint stripping systems is applicable to depainting activities on large off-aircraft components and weapons systems for the Air Force...The use of laser paint stripping systems is applicable to depainting activities on large off-aircraft components and weapons systems for the Air
Fallah, F; Minaei Chenar, H; Amiri, H; Omodipour, S; Shirbande Ghods, F; Kahrizi, D; Sohrabi, M; Ghorbani, T; Kazemi, E
2017-02-28
High quality DNA is essential for molecular research. Secondary metabolites can affect the quantity and quality DNA. In current research two DNA isolation methods including CTAB and Delaporta (protocols 1 & 2 respectively) were applied in three leave samples from Cotinus coggygria, Citrus sinensis and Genus juglans that their leaves are rich of secondary metabolites. We successfully isolated DNA from C. coggygria, C. sinensis and Genus Juglans using the two protocols described above. Good quality DNA was isolated from C. coggygria, C. sinensis and Genus Juglans using protocol 1, while protocol 2 failed to produce usable DNA from these sources. The highest amount of DNA (1.3-1.6) was obtained from them using protocol 1. As we discovered, procedure 1 may work better for plants with secondary metabolites.
NASA Astrophysics Data System (ADS)
Phister, P. W., Jr.
1983-12-01
Development of the Air Force Institute of Technology's Digital Engineering Laboratory Network (DELNET) was continued with the development of an initial draft of a protocol standard for all seven layers as specified by the International Standards Organization's (ISO) Reference Model for Open Systems Interconnections. This effort centered on the restructuring of the Network Layer to perform Datagram routing and to conform to the developed protocol standards and actual software module development of the upper four protocol layers residing within the DELNET Monitor (Zilog MCZ 1/25 Computer System). Within the guidelines of the ISO Reference Model the Transport Layer was developed utilizing the Internet Header Format (IHF) combined with the Transport Control Protocol (TCP) to create a 128-byte Datagram. Also a limited Application Layer was created to pass the Gettysburg Address through the DELNET. This study formulated a first draft for the DELNET Protocol Standard and designed, implemented, and tested the Network, Transport, and Application Layers to conform to these protocol standards.
Paoletti, Claudia; Esbensen, Kim H
2015-01-01
Material heterogeneity influences the effectiveness of sampling procedures. Most sampling guidelines used for assessment of food and/or feed commodities are based on classical statistical distribution requirements, the normal, binomial, and Poisson distributions-and almost universally rely on the assumption of randomness. However, this is unrealistic. The scientific food and feed community recognizes a strong preponderance of non random distribution within commodity lots, which should be a more realistic prerequisite for definition of effective sampling protocols. Nevertheless, these heterogeneity issues are overlooked as the prime focus is often placed only on financial, time, equipment, and personnel constraints instead of mandating acquisition of documented representative samples under realistic heterogeneity conditions. This study shows how the principles promulgated in the Theory of Sampling (TOS) and practically tested over 60 years provide an effective framework for dealing with the complete set of adverse aspects of both compositional and distributional heterogeneity (material sampling errors), as well as with the errors incurred by the sampling process itself. The results of an empirical European Union study on genetically modified soybean heterogeneity, Kernel Lot Distribution Assessment are summarized, as they have a strong bearing on the issue of proper sampling protocol development. TOS principles apply universally in the food and feed realm and must therefore be considered the only basis for development of valid sampling protocols free from distributional constraints.
Kalim, Shahid; Nazir, Shaista; Khan, Zia Ullah
2013-01-01
Protocols based on newer high sensitivity Troponin T (hsTropT) assays can rule in a suspected Acute Myocardial Infarction (AMI) as early as 3 hours. We conducted this study to audit adherence to our Trust's newly introduced AMI diagnostic protocol based on paired hsTropT testing at 0 and 3 hours. We retrospectively reviewed data of all patients who had hsTropT test done between 1st and 7th May 2012. Patient's demographics, utility of single or paired samples, time interval between paired samples, patient's presenting symptoms and ECG findings were noted and their means, medians, Standard deviations and proportions were calculated. A total of 66 patients had hsTropT test done during this period. Mean age was 63.30 +/- 17.46 years and 38 (57.57%) were males. Twenty-four (36.36%) patients had only single, rather than protocol recommended paired hsTropT samples, taken. Among the 42 (63.63%) patients with paired samples, the mean time interval was found to be 4.41 +/- 5.7 hours. Contrary to the recommendations, 15 (22.73%) had a very long whereas 2 (3.03%) had a very short time interval between two samples. A subgroup analysis of patients with single samples, found only 2 (3.03%) patient with ST-segment elevation, appropriate for single testing. Our study confirmed that in a large number of patients the protocol for paired sampling or a recommended time interval of 3 hours between 2 samples was not being followed.
Laurin, Nancy; DeMoors, Anick; Frégeau, Chantal
2012-09-01
Direct amplification of STR loci from biological samples collected on FTA cards without prior DNA purification was evaluated using Identifiler Direct and PowerPlex 16 HS in conjunction with the use of a high throughput Applied Biosystems 3730 DNA Analyzer. In order to reduce the overall sample processing cost, reduced PCR volumes combined with various FTA disk sizes were tested. Optimized STR profiles were obtained using a 0.53 mm disk size in 10 μL PCR volume for both STR systems. These protocols proved effective in generating high quality profiles on the 3730 DNA Analyzer from both blood and buccal FTA samples. Reproducibility, concordance, robustness, sample stability and profile quality were assessed using a collection of blood and buccal samples on FTA cards from volunteer donors as well as from convicted offenders. The new developed protocols offer enhanced throughput capability and cost effectiveness without compromising the robustness and quality of the STR profiles obtained. These results support the use of these protocols for processing convicted offender samples submitted to the National DNA Data Bank of Canada. Similar protocols could be applied to the processing of casework reference samples or in paternity or family relationship testing. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Erramuzpe, Asier; Cortés, Jesús M; López, José I
2018-02-01
Intratumor heterogeneity (ITH) is an inherent process of tumor development that has received much attention in previous years, as it has become a major obstacle for the success of targeted therapies. ITH is also temporally unpredictable across tumor evolution, which makes its precise characterization even more problematic since detection success depends on the precise temporal snapshot at which ITH is analyzed. New and more efficient strategies for tumor sampling are needed to overcome these difficulties which currently rely entirely on the pathologist's interpretation. Recently, we showed that a new strategy, the multisite tumor sampling, works better than the routine sampling protocol for the ITH detection when the tumor time evolution was not taken into consideration. Here, we extend this work and compare the ITH detections of multisite tumor sampling and routine sampling protocols across tumor time evolution, and in particular, we provide in silico analyses of both strategies at early and late temporal stages for four different models of tumor evolution (linear, branched, neutral, and punctuated). Our results indicate that multisite tumor sampling outperforms routine protocols in detecting ITH at all different temporal stages of tumor evolution. We conclude that multisite tumor sampling is more advantageous than routine protocols in detecting intratumor heterogeneity.
Environmental DNA sampling protocol - filtering water to capture DNA from aquatic organisms
Laramie, Matthew B.; Pilliod, David S.; Goldberg, Caren S.; Strickler, Katherine M.
2015-09-29
Environmental DNA (eDNA) analysis is an effective method of determining the presence of aquatic organisms such as fish, amphibians, and other taxa. This publication is meant to guide researchers and managers in the collection, concentration, and preservation of eDNA samples from lentic and lotic systems. A sampling workflow diagram and three sampling protocols are included as well as a list of suggested supplies. Protocols include filter and pump assembly using: (1) a hand-driven vacuum pump, ideal for sample collection in remote sampling locations where no electricity is available and when equipment weight is a primary concern; (2) a peristaltic pump powered by a rechargeable battery-operated driver/drill, suitable for remote sampling locations when weight consideration is less of a concern; (3) a 120-volt alternating current (AC) powered peristaltic pump suitable for any location where 120-volt AC power is accessible, or for roadside sampling locations. Images and detailed descriptions are provided for each step in the sampling and preservation process.
Multi-platform metabolomics assays for human lung lavage fluids in an air pollution exposure study.
Surowiec, Izabella; Karimpour, Masoumeh; Gouveia-Figueira, Sandra; Wu, Junfang; Unosson, Jon; Bosson, Jenny A; Blomberg, Anders; Pourazar, Jamshid; Sandström, Thomas; Behndig, Annelie F; Trygg, Johan; Nording, Malin L
2016-07-01
Metabolomics protocols are used to comprehensively characterize the metabolite content of biological samples by exploiting cutting-edge analytical platforms, such as gas chromatography (GC) or liquid chromatography (LC) coupled to mass spectrometry (MS) assays, as well as nuclear magnetic resonance (NMR) assays. We have developed novel sample preparation procedures combined with GC-MS, LC-MS, and NMR metabolomics profiling for analyzing bronchial wash (BW) and bronchoalveolar lavage (BAL) fluid from 15 healthy volunteers following exposure to biodiesel exhaust and filtered air. Our aim was to investigate the responsiveness of metabolite profiles in the human lung to air pollution exposure derived from combustion of biofuels, such as rapeseed methyl ester biodiesel, which are increasingly being promoted as alternatives to conventional fossil fuels. Our multi-platform approach enabled us to detect the greatest number of unique metabolites yet reported in BW and BAL fluid (82 in total). All of the metabolomics assays indicated that the metabolite profiles of the BW and BAL fluids differed appreciably, with 46 metabolites showing significantly different levels in the corresponding lung compartments. Furthermore, the GC-MS assay revealed an effect of biodiesel exhaust exposure on the levels of 1-monostearylglycerol, sucrose, inosine, nonanoic acid, and ethanolamine (in BAL) and pentadecanoic acid (in BW), whereas the LC-MS assay indicated a shift in the levels of niacinamide (in BAL). The NMR assay only identified lactic acid (in BW) as being responsive to biodiesel exhaust exposure. Our findings demonstrate that the proposed multi-platform approach is useful for wide metabolomics screening of BW and BAL fluids and can facilitate elucidation of metabolites responsive to biodiesel exhaust exposure. Graphical Abstract Graphical abstract illustrating the study workflow. NMR Nuclear Magnetic Resonance, LC-TOFMS Liquid chromatography-Time Of Flight Mass Spectrometry, GC Gas Chromatography-Mass spectrometry.
Borge, Rafael; Artíñano, Begoña; Yagüe, Carlos; Gomez-Moreno, Francisco Javier; Saiz-Lopez, Alfonso; Sastre, Mariano; Narros, Adolfo; García-Nieto, David; Benavent, Nuria; Maqueda, Gregorio; Barreiro, Marcos; de Andrés, Juan Manuel; Cristóbal, Ángeles
2018-03-28
Exceedances of NO 2 hourly limit value (200 μg·m -3 ) imply the need to implement short term action plans to avoid adverse effects on human health in urban areas. The Madrid City Council applied the stage 3 of the NO 2 protocol during a high-pollution episode under stable meteorological conditions on December 2016 for the first time. This included road traffic access restrictions to the city centre (50% of conventional private vehicles based on plate numbers). In this contribution we analyse different meteorological and air quality observations, including non-standard parameters (such as number of ultrafine particles and remote sensing techniques MAXDOAS) for a better understanding of the effectivity of short-term emission abatement measures under real conditions and to identify options to improve the NO 2 protocol in the future. According to our results, the inversion base height computed from vertical temperature soundings is a meaningful index to anticipate very unfavourable conditions and trigger the actions included in the protocol. The analysis of the concentration levels of the main pollutants from the Madrid air quality monitoring network indicate that only stage 3 of the protocol had a significant effect on NO 2 maximum concentrations. The restrictions applied may have prevented NO 2 concentrations to further increase in the city centre (up to 15%) although pollution levels in the city outskirts, outside the area directly affected by the traffic restrictions, remained unchanged or may have been slightly increased. Nonetheless, further studies are needed to estimate more precisely the effect of the measures taken and to assess potential trade-offs. Our results suggest that emissions play an important role also under very strong stability conditions although drastic measures are needed to achieve a significant impact. This highlights the importance of an appropriate timing for short-term actions and the need of permanent abatement measures related to air quality plans and policies. Copyright © 2018 Elsevier B.V. All rights reserved.
Jeddi, Fakhri; Yapo-Kouadio, Gisèle Cha; Normand, Anne-Cécile; Cassagne, Carole; Marty, Pierre; Piarroux, Renaud
2017-02-01
In cases of fungal infection of the bloodstream, rapid species identification is crucial to provide adapted therapy and thereby ameliorate patient outcome. Currently, the commercial Sepsityper kit and the sodium-dodecyl sulfate (SDS) method coupled with MALDI-TOF mass spectrometry are the most commonly reported lysis protocols for direct identification of fungi from positive blood culture vials. However, the performance of these two protocols has never been compared on clinical samples. Accordingly, we performed a two-step survey on two distinct panels of clinical positive blood culture vials to identify the most efficient protocol, establish an appropriate log score (LS) cut-off, and validate the best method. We first compared the performance of the Sepsityper and the SDS protocols on 71 clinical samples. For 69 monomicrobial samples, mass spectrometry LS values were significantly higher with the SDS protocol than with the Sepsityper method (P < .0001), especially when the best score of four deposited spots was considered. Next, we established the LS cut-off for accurate identification at 1.7, based on specimen DNA sequence data. Using this LS cut-off, 66 (95.6%) and 46 (66.6%) isolates were correctly identified at the species level with the SDS and the Sepsityper protocols, respectively. In the second arm of the survey, we validated the SDS protocol on an additional panel of 94 clinical samples. Ninety-two (98.9%) of 93 monomicrobial samples were correctly identified at the species level (median LS = 2.061). Overall, our data suggest that the SDS method yields more accurate species identification of yeasts, than the Sepsityper protocol. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Carbon Offsets in California: What Role for Earth Scientists in the Policy Process? (Invited)
NASA Astrophysics Data System (ADS)
Cullenward, D.; Strong, A. L.
2013-12-01
This talk addresses the policy structure in California for developing and approving carbon offset protocols, which rely on findings from the environmental and earth sciences communities. In addition to providing an overview of the legal requirements of carbon offsets, we describe a series of case studies of how scientists can engage with policymakers. Based on those experiences, we suggest ways for the earth sciences community to become more involved in climate policy development. California's climate law, known as AB 32, requires that major sectors of the state's economy reduce their emissions to 1990 levels by 2020. As part of AB 32, the California Air Resources Board created a cap-and-trade market to ensure compliance with the statutory target. Under this system, regulated companies have to acquire tradable emissions permits (called 'compliance instruments') for the greenhouse gas emissions they release. The State allocates a certain number of allowances to regulated entities through a mixture of auctions and free transfers, with the total number equal to the overall emissions target; these allowances, along with approved offsets credits, are the compliance instruments that regulated entities are required to obtain by law. One of the key policy design issues in California's cap-and-trade market concerns the use of carbon offsets. Under AB 32, the Air Resources Board can issue offset credits to project developers who reduce emissions outside of the capped sectors (electricity, industry, and transportation)--or even outside of California--pursuant to approved offset protocols. Project developers then sell the credits to regulated companies in California. Essentially, offsets allow regulated entities in California to earn credit for emissions reductions that take place outside the scope of AB 32. Many regulated entities and economists are in favor of offsets because they view them as a source of low-cost compliance instruments. On the other hand, critics argue that some offset protocols award credits for activities that would have occurred anyway; by replacing a company's need to acquire an allowance in the carbon market, critics believe that poorly designed offset protocols increase greenhouse gas emissions. Thus, the effectiveness of the policy approach depends on the scientific integrity of the offset protocols. To date, California has approved offset protocols for emissions reductions in four applications: (1) forestry, (2) urban forestry, (3) livestock, and (4) destruction of ozone-depleting substances. In addition, the State is currently considering protocols that would address (5) methane emissions from mining and (6) greenhouse gas reductions from improved rice cultivation practices. These protocols rely heavily on findings from the environmental and earth sciences communities, especially when the protocol subject involves land use or land use change. Yet, due to budget constraints, the Air Resources Board is relying primarily on third-party protocol developers to design and propose the detailed structures under which offset credits will be issued. Despite the fact that any member of the public may participate in the governance regime that leads to protocol approvals, few scientists or scientific organizations provide input into the policy process. We use case studies from several of the California protocols to illustrate ways scientists can apply their skills to a crucial stage of climate policy development.
Adaptive Sampling for Urban Air Quality through Participatory Sensing
Zeng, Yuanyuan; Xiang, Kai
2017-01-01
Air pollution is one of the major problems of the modern world. The popularization and powerful functions of smartphone applications enable people to participate in urban sensing to better know about the air problems surrounding them. Data sampling is one of the most important problems that affect the sensing performance. In this paper, we propose an Adaptive Sampling Scheme for Urban Air Quality (AS-air) through participatory sensing. Firstly, we propose to find the pattern rules of air quality according to the historical data contributed by participants based on Apriori algorithm. Based on it, we predict the on-line air quality and use it to accelerate the learning process to choose and adapt the sampling parameter based on Q-learning. The evaluation results show that AS-air provides an energy-efficient sampling strategy, which is adaptive toward the varied outside air environment with good sampling efficiency. PMID:29099766
Optimization of Native and Formaldehyde iPOND Techniques for Use in Suspension Cells.
Wiest, Nathaniel E; Tomkinson, Alan E
2017-01-01
The isolation of proteins on nascent DNA (iPOND) technique developed by the Cortez laboratory allows a previously unparalleled ability to examine proteins associated with replicating and newly synthesized DNA in mammalian cells. Both the original, formaldehyde-based iPOND technique and a more recent derivative, accelerated native iPOND (aniPOND), have mostly been performed in adherent cell lines. Here, we describe modifications to both protocols for use with suspension cell lines. These include cell culture, pulse, and chase conditions that optimize sample recovery in both protocols using suspension cells and several key improvements to the published aniPOND technique that reduce sample loss, increase signal to noise, and maximize sample recovery. Additionally, we directly and quantitatively compare the iPOND and aniPOND protocols to test the strengths and limitations of both. Finally, we present a detailed protocol to perform the optimized aniPOND protocol in suspension cell lines. © 2017 Elsevier Inc. All rights reserved.
Corrosion and mechanical performance of AZ91 exposed to simulated inflammatory conditions.
Brooks, Emily K; Der, Stephanie; Ehrensberger, Mark T
2016-03-01
Magnesium (Mg) and its alloys, including Mg-9%Al-1%Zn (AZ91), are biodegradable metals with potential use as temporary orthopedic implants. Invasive orthopedic procedures can provoke an inflammatory response that produces hydrogen peroxide (H2O2) and an acidic environment near the implant. This study assessed the influence of inflammation on both the corrosion and mechanical properties of AZ91. The AZ91 samples in the inflammatory protocol were immersed for three days in a complex biologically relevant electrolyte (AMEM culture media) that contained serum proteins (FBS), 150 mM of H2O2, and was titrated to a pH of 5. The control protocol immersed AZ91 samples in the same biologically relevant electrolyte (AMEM & FBS) but without H2O2 and the acid titration. After 3 days all samples were switched into fresh AMEM & FBS for an additional 3-day immersion. During the initial immersion, inflammatory protocol samples showed increased corrosion rate determined by mass loss testing, increased Mg and Al ion released to solution, and a completely corroded surface morphology as compared to the control protocol. Although corrosion in both protocols slowed once the test electrolyte solution was replaced at 3 days, the samples originally exposed to the simulated inflammatory conditions continued to display enhanced corrosion rates as compared to the control protocol. These lingering effects may indicate the initial inflammatory corrosion processes modified components of the surface oxide and corrosion film or initiated aggressive localized processes that subsequently left the interface more vulnerable to continued enhanced corrosion. The electrochemical properties of the interfaces were also evaluated by EIS, which found that the corrosion characteristics of the AZ91 samples were potentially influenced by the role of intermediate adsorption layer processes. The increased corrosion observed for the inflammatory protocol did not affect the flexural mechanical properties of the AZ91 at any time point assessed. Copyright © 2015 Elsevier B.V. All rights reserved.
Two Decades into the LCR: What We Do and Still Don’t Know to Solve Lead Problems
Site selection and sampling protocol biases in LCR samplingunderestimate peak lead and copper concentrations whilemissing erratic lead release episodes resulting from distributionsystem chemical and physical disturbances. Possible sitetargeting and sampling protocol changes could...
Vascular Blood Collection protocol samples into MELFI
2011-10-18
iss029e028495 (10/18/2011) --- Japan Aerospace Exploration Agency astronaut Satoshi Furukawa,Expedition 29 flight engineer,prepares to put samples from the CSA (Canadian Space Agency) Vascular Blood Collection protocol into the MELFI-1 (Minus Eighty Laboratory Freezer for ISS 1) unit.
Two Decades into the LCR: What We Do and Still Don’t Know to Solve Lead Problems - abstract
Site selection and sampling protocol biases in LCR samplingunderestimate peak lead and copper concentrations whilemissing erratic lead release episodes resulting from distributionsystem chemical and physical disturbances. Possible sitetargeting and sampling protocol changes could...
NHEXAS PHASE I ARIZONA STUDY--LIST OF STANDARD OPERATING PROCEDURES
This document lists available protocols and SOPs for the NHEXAS Phase I Arizona study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assurance, (...
NASA Astrophysics Data System (ADS)
Yang, M. M.; Blake, D. R.
2009-12-01
The San Joaquin Valley Air Basin in Central California is plagued with air quality problems, and is classified by the U.S. Environmental Protection Agency (EPA) as a serious non-attainment area for health-based eight-hour federal ozone (smog) standard (1). One of the main sources of Volatile Organic Compounds (VOCs), and indirect sources of ozone in the Valley, has been identified as dairy farming (2). Among these compounds, we have found that several OVOCs such as ethanol, methanol, acetone and acetaldehyde are produced in major quantities throughout the San Joaquin valley as by-products of yeast fermentation of silage and photochemical oxidation. These oxygenates, especially ethanol, play an important role in ozone (O3) formation within the valley. Since 2008, several different types of sampling protocols have been employed by our group in order to determine the degree of enhancement of the four oxygenates in the valley air shed, as well as to determine their sources, emission profiles and emission rates (2). In 2008 and 2009, samples were in early summer, allowing us to compare the difference in concentration levels between both years.The photochemical production of ozone was calculated for each of the four oxygenates and approximately one hundred other quantified VOCs. Based on the Maximum Incremental Reactivity (MIR) scale and concentrations of each oxygenate in the atmosphere, for both 2008 and 2009, as much as 15% of O3 production in the valley is from ethanol and its photochemical by-product acetaldehyde. Our findings suggest that the data observed in 2008 is consistent with that observed in 2009, with a slight decrease in concentrations overall for 2009. 1. Lindberg, J. Analysis of the San Joaquin Valley 2007 Ozone Plan. State of California Air Resources Board. Final Draft Staff Report. 5/30/2007. 2. M. Yang, S. Meinardi, C. Krauter, D.R. Blake. Characterization of VOC Emissions from Various Components of Dairy Farming and their effect on San Joaquin Valley Air Quality. American Geophysical Union, Fall Meeting 2008, abstract #A53A-0241
NASA Astrophysics Data System (ADS)
Liu, Yongfang; Zhao, Yu; Chen, Guanrong
2016-11-01
This paper studies the distributed consensus and containment problems for a group of harmonic oscillators with a directed communication topology. First, for consensus without a leader, a class of distributed consensus protocols is designed by using motion planning and Pontryagin's principle. The proposed protocol only requires relative information measurements at the sampling instants, without requiring information exchange over the sampled interval. By using stability theory and the properties of stochastic matrices, it is proved that the distributed consensus problem can be solved in the motion planning framework. Second, for the case with multiple leaders, a class of distributed containment protocols is developed for followers such that their positions and velocities can ultimately converge to the convex hull formed by those of the leaders. Compared with the existing consensus algorithms, a remarkable advantage of the proposed sampled-data-based protocols is that the sampling periods, communication topologies and control gains are all decoupled and can be separately designed, which relaxes many restrictions in controllers design. Finally, some numerical examples are given to illustrate the effectiveness of the analytical results.
Christopher W. Woodall; Vicente J. Monleon
2008-01-01
The USDA Forest Service's Forest Inventory and Analysis program conducts an inventory of forests of the United States including down woody materials (DWM). In this report we provide the rationale and context for a national inventory of DWM, describe the components sampled, discuss the sampling protocol used and corresponding estimation procedures, and provide...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Jianying; Dann, Geoffrey P.; Shi, Tujin
2012-03-10
Sodium dodecyl sulfate (SDS) is one of the most popular laboratory reagents used for highly efficient biological sample extraction; however, SDS presents a significant challenge to LC-MS-based proteomic analyses due to its severe interference with reversed-phase LC separations and electrospray ionization interfaces. This study reports a simple SDS-assisted proteomic sample preparation method facilitated by a novel peptide-level SDS removal protocol. After SDS-assisted protein extraction and digestion, SDS was effectively (>99.9%) removed from peptides through ion substitution-mediated DS- precipitation with potassium chloride (KCl) followed by {approx}10 min centrifugation. Excellent peptide recovery (>95%) was observed for less than 20 {mu}g of peptides.more » Further experiments demonstrated the compatibility of this protocol with LC-MS/MS analyses. The resulting proteome coverage from this SDS-assisted protocol was comparable to or better than those obtained from other standard proteomic preparation methods in both mammalian tissues and bacterial samples. These results suggest that this SDS-assisted protocol is a practical, simple, and broadly applicable proteomic sample processing method, which can be particularly useful when dealing with samples difficult to solubilize by other methods.« less
Johanson, Helene C; Hyland, Valentine; Wicking, Carol; Sturm, Richard A
2009-04-01
We describe here a method for DNA elution from buccal cells and whole blood both collected onto Whatman FTA technology, using methanol fixation followed by an elution PCR program. Extracted DNA is comparable in quality to published Whatman FTA protocols, as judged by PCR-based genotyping. Elution of DNA from the dried sample is a known rate-limiting step in the published Whatman FTA protocol; this method enables the use of each 3-mm punch of sample for several PCR reactions instead of the standard, one PCR reaction per sample punch. This optimized protocol therefore extends the usefulness and cost effectiveness of each buccal swab sample collected, when used for nucleic acid PCR and genotyping.
Beikircher, Barbara; Mayr, Stefan
2016-01-01
A prerequisite for reliable hydraulic measurements is an accurate collection of the plant material. Thereby, the native hydraulic state of the sample has to be preserved during harvesting (i.e., cutting the plant or plant parts) and preparation (i.e., excising the target section). This is particularly difficult when harvesting has to be done under transpiring conditions. In this article, we present a harvesting and sampling protocol designed for hydraulic measurements on Malus domestica Borkh. and checked for possible sampling artefacts. To test for artefacts, we analysed the percentage loss of hydraulic conductivity, maximum specific conductivity and water contents of bark and wood of branches, taking into account conduit length, time of day of harvesting, different shoot ages and seasonal effects. Our results prove that use of appropriate protocols can avoid artefactual embolization or refilling even when the xylem is under tension at harvest. The presented protocol was developed for Malus but may also be applied for other angiosperms with similar anatomy and refilling characteristics. PMID:26705311
Eight Year Climatologies from Observational (AIRS) and Model (MERRA) Data
NASA Technical Reports Server (NTRS)
Hearty, Thomas; Savtchenko, Andrey; Won, Young-In; Theobalk, Mike; Vollmer, Bruce; Manning, Evan; Smith, Peter; Ostrenga, Dana; Leptoukh, Greg
2010-01-01
We examine climatologies derived from eight years of temperature, water vapor, cloud, and trace gas observations made by the Atmospheric Infrared Sounder (AIRS) instrument flying on the Aqua satellite and compare them to similar climatologies constructed with data from a global assimilation model, the Modern Era Retrospective-Analysis for Research and Applications (MERRA). We use the AIRS climatologies to examine anomalies and trends in the AIRS data record. Since sampling can be an issue for infrared satellites in low earth orbit, we also use the MERRA data to examine the AIRS sampling biases. By sampling the MERRA data at the AIRS space-time locations both with and without the AIRS quality control we estimate the sampling bias of the AIRS climatology and the atmospheric conditions where AIRS has a lower sampling rate. While the AIRS temperature and water vapor sampling biases are small at low latitudes, they can be more than a few degrees in temperature or 10 percent in water vapor at higher latitudes. The largest sampling biases are over desert. The AIRS and MERRA data are available from the Goddard Earth Sciences Data and Information Services Center (GES DISC). The AIRS climatologies we used are available for analysis with the GIOVANNI data exploration tool. (see, http://disc.gsfc.nasa.gov).
Rapid Waterborne Pathogen Detection with Mobile Electronics.
Wu, Tsung-Feng; Chen, Yu-Chen; Wang, Wei-Chung; Kucknoor, Ashwini S; Lin, Che-Jen; Lo, Yu-Hwa; Yao, Chun-Wei; Lian, Ian
2017-06-09
Pathogen detection in water samples, without complex and time consuming procedures such as fluorescent-labeling or culture-based incubation, is essential to public safety. We propose an immunoagglutination-based protocol together with the microfluidic device to quantify pathogen levels directly from water samples. Utilizing ubiquitous complementary metal-oxide-semiconductor (CMOS) imagers from mobile electronics, a low-cost and one-step reaction detection protocol is developed to enable field detection for waterborne pathogens. 10 mL of pathogen-containing water samples was processed using the developed protocol including filtration enrichment, immune-reaction detection and imaging processing. The limit of detection of 10 E. coli O157:H7 cells/10 mL has been demonstrated within 10 min of turnaround time. The protocol can readily be integrated into a mobile electronics such as smartphones for rapid and reproducible field detection of waterborne pathogens.
FISH-in-CHIPS: A Microfluidic Platform for Molecular Typing of Cancer Cells.
Perez-Toralla, Karla; Mottet, Guillaume; Tulukcuoglu-Guneri, Ezgi; Champ, Jérôme; Bidard, François-Clément; Pierga, Jean-Yves; Klijanienko, Jerzy; Draskovic, Irena; Malaquin, Laurent; Viovy, Jean-Louis; Descroix, Stéphanie
2017-01-01
Microfluidics offer powerful tools for the control, manipulation, and analysis of cells, in particular for the assessment of cell malignancy or the study of cell subpopulations. However, implementing complex biological protocols on chip remains a challenge. Sample preparation is often performed off chip using multiple manually performed steps, and protocols usually include different dehydration and drying steps that are not always compatible with a microfluidic format.Here, we report the implementation of a Fluorescence in situ Hybridization (FISH) protocol for the molecular typing of cancer cells in a simple and low-cost device. The geometry of the chip allows integrating the sample preparation steps to efficiently assess the genomic content of individual cells using a minute amount of sample. The FISH protocol can be fully automated, thus enabling its use in routine clinical practice.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-11
...Recent EPA gas audit results indicate that some gas cylinders used to calibrate continuous emission monitoring systems on stationary sources do not meet EPA's performance specification. Reviews of stack test reports in recent years indicate that some stack testers do not properly follow EPA test methods or do not correctly calculate test method results. Therefore, EPA is proposing to amend its Protocol Gas Verification Program (PGVP) and the minimum competency requirements for air emission testing (formerly air emission testing body requirements) to improve the accuracy of emissions data. EPA is also proposing to amend other sections of the Acid Rain Program continuous emission monitoring system regulations by adding and clarifying certain recordkeeping and reporting requirements, removing the provisions pertaining to mercury monitoring and reporting, removing certain requirements associated with a class-approved alternative monitoring system, disallowing the use of a particular quality assurance option in EPA Reference Method 7E, adding an incorporation by reference that was inadvertently left out of the January 24, 2008 final rule, and clarifying the language and applicability of certain provisions.
Near-optimal protocols in complex nonequilibrium transformations
Gingrich, Todd R.; Rotskoff, Grant M.; Crooks, Gavin E.; ...
2016-08-29
The development of sophisticated experimental means to control nanoscale systems has motivated efforts to design driving protocols that minimize the energy dissipated to the environment. Computational models are a crucial tool in this practical challenge. In this paper, we describe a general method for sampling an ensemble of finite-time, nonequilibrium protocols biased toward a low average dissipation. In addition, we show that this scheme can be carried out very efficiently in several limiting cases. As an application, we sample the ensemble of low-dissipation protocols that invert the magnetization of a 2D Ising model and explore how the diversity of themore » protocols varies in response to constraints on the average dissipation. In this example, we find that there is a large set of protocols with average dissipation close to the optimal value, which we argue is a general phenomenon.« less
75 FR 68784 - Healthy Indoor Environment Protocols for Home Energy Upgrades
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-09
... Home Energy Upgrades, in conjunction with the availability of the Department of Energy (DOE) Workforce... also provide the specific responses necessary to maintain or improve indoor air quality in conjunction...
Protocols for Home Energy Upgrades
Remodeling or renovating an existing home not only has the potential to release pollutants into the home; it is also an opportunity to make changes that will improve the indoor air quality in your home.
Evaluation of prototype air/fluid separator for Space Station Freedom Health Maintenance Facility
NASA Technical Reports Server (NTRS)
Billica, Roger; Smith, Maureen; Murphy, Linda; Kizzee, Victor D.
1991-01-01
A prototype air/fluid separator suction apparatus proposed as a possible design for use with the Health Maintenance Facility aboard Space Station Freedom (SSF) was evaluated. A KC-135 parabolic flight test was performed for this purpose. The flights followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola. A protocol was prepared to evaluate the prototype device in several regulator modes (or suction force), using three fluids of varying viscosity, and using either continuous or intermittent suction. It was felt that a matrixed approach would best approximate the range of utilization anticipated for medical suction on SSF. The protocols were performed in one-gravity in a lab setting to familiarize the team with procedures and techniques. Identical steps were performed aboard the KC-135 during parabolic flight.
Exploring the Implementation of Steganography Protocols on Quantum Audio Signals
NASA Astrophysics Data System (ADS)
Chen, Kehan; Yan, Fei; Iliyasu, Abdullah M.; Zhao, Jianping
2018-02-01
Two quantum audio steganography (QAS) protocols are proposed, each of which manipulates or modifies the least significant qubit (LSQb) of the host quantum audio signal that is encoded as an FRQA (flexible representation of quantum audio) audio content. The first protocol (i.e. the conventional LSQb QAS protocol or simply the cLSQ stego protocol) is built on the exchanges between qubits encoding the quantum audio message and the LSQb of the amplitude information in the host quantum audio samples. In the second protocol, the embedding procedure to realize it implants information from a quantum audio message deep into the constraint-imposed most significant qubit (MSQb) of the host quantum audio samples, we refer to it as the pseudo MSQb QAS protocol or simply the pMSQ stego protocol. The cLSQ stego protocol is designed to guarantee high imperceptibility between the host quantum audio and its stego version, whereas the pMSQ stego protocol ensures that the resulting stego quantum audio signal is better immune to illicit tampering and copyright violations (a.k.a. robustness). Built on the circuit model of quantum computation, the circuit networks to execute the embedding and extraction algorithms of both QAS protocols are determined and simulation-based experiments are conducted to demonstrate their implementation. Outcomes attest that both protocols offer promising trade-offs in terms of imperceptibility and robustness.
Worldwide Environmental Compliance Assessment and Management Program (ECAMP)
1991-01-01
shop is derived as follows: 1. The paint shop has many enviromnntal concerns: -wi - - emissions from painting activities -proper storae of flammable and...stripping compounds, and paint solids into the storm or sanitary systems. Protocols tit apply are: -Air Emissions M en n -Haarous Materials Mr~nn...in Air Emissions an ~enr spray painiM or surface coating operations questions - in Hazarious Materials Mas enx storage of flanmble/combustible
Preparation of the NASA Air Quality Monitor for a U.S. Navy Submarine Sea Trial
NASA Technical Reports Server (NTRS)
Limero, Thomas; Wallace, William T.; Manney, Joshua A.; Smith, Matthew J.; O'Connor, Sara Jane; Mudgett, Paul D.
2017-01-01
For the past 4 years, the Air Quality Monitor (AQM) has been the operational instrument for measuring trace volatile organic compounds on the International Space Station (ISS). The key components of the AQM are the inlet preconcentrator, the gas chromatograph (GC), and the differential mobility spectrometer. Onboard the ISS are two AQMs with different GC columns that detect and quantify 22 compounds. The AQM data contributes valuable information to the assessment of air quality aboard ISS for each crew increment. The US Navy is looking to update its submarine air monitoring suite of instruments and the success of the AQM on ISS has led to a jointly planned submarine sea trial of a NASA AQM. In addition to the AQM, the Navy is also interested in the Multi-Gas Monitor (MGM), which measures major constituent gases (oxygen, carbon dioxide, water vapor, and ammonia). A separate paper will present the MGM sea trial preparation and the analysis of most recent ISS data. A prototype AQM, which is virtually identical to the operational AQM, has been readied for the sea trial. Only one AQM will be deployed during the sea trial, but this is sufficient for NASA purposes and to detect the compounds of interest to the US Navy for this trial. The data from the sea trial will be compared to data from archival samples collected before, during, and after the trial period. This paper will start with a brief history of past collaborations between NASA and the U.S. and U.K. navies for trials of air monitoring equipment. An overview of the AQM technology and protocols for the submarine trial will be presented. The majority of the presentation will focus on the AQM preparation and a summary of available data from the trial.
Sub-nanometer Resolution Imaging with Amplitude-modulation Atomic Force Microscopy in Liquid
Farokh Payam, Amir; Piantanida, Luca; Cafolla, Clodomiro; Voïtchovsky, Kislon
2016-01-01
Atomic force microscopy (AFM) has become a well-established technique for nanoscale imaging of samples in air and in liquid. Recent studies have shown that when operated in amplitude-modulation (tapping) mode, atomic or molecular-level resolution images can be achieved over a wide range of soft and hard samples in liquid. In these situations, small oscillation amplitudes (SAM-AFM) enhance the resolution by exploiting the solvated liquid at the surface of the sample. Although the technique has been successfully applied across fields as diverse as materials science, biology and biophysics and surface chemistry, obtaining high-resolution images in liquid can still remain challenging for novice users. This is partly due to the large number of variables to control and optimize such as the choice of cantilever, the sample preparation, and the correct manipulation of the imaging parameters. Here, we present a protocol for achieving high-resolution images of hard and soft samples in fluid using SAM-AFM on a commercial instrument. Our goal is to provide a step-by-step practical guide to achieving high-resolution images, including the cleaning and preparation of the apparatus and the sample, the choice of cantilever and optimization of the imaging parameters. For each step, we explain the scientific rationale behind our choices to facilitate the adaptation of the methodology to every user's specific system. PMID:28060262
USGS/EPA collection protocol for bacterial pathogens in soil
Griffin, Dale W.; Shaefer, F.L.; Charlena Bowling,; Dino Mattorano,; Tonya Nichols,; Erin Silvestri,
2014-01-01
This Sample Collection Procedure (SCP) describes the activities and considerations for the collection of bacterial pathogens from representative surface soil samples (0-5 cm). This sampling depth can be reached without the use of a drill rig, direct-push technology, or other mechanized equipment. This procedure can be used in most soil types but is limited to sampling at or near the ground surface. This protocol has components for two different types of sampling applications: (1) typical sampling, when there is no suspicion of contamination (e.g., surveillance or background studies); and (2) in response to known or suspected accidental contamination (e.g., the presence of animal carcasses). This protocol does not cover sampling in response to a suspected bioterrorist or intentional release event. Surface material is removed to the required depth (0-5 cm) and clean trowel or 50 ml sample tube is used to collect the sample. Sample containers are sealed, bagged, and shipped to the laboratory for analysis. Associated documentation, including a Field Data Log and Chain-of-Custody are also included in this document.
Keiter, David A.; Cunningham, Fred L.; Rhodes, Olin E.; Irwin, Brian J.; Beasley, James
2016-01-01
Collection of scat samples is common in wildlife research, particularly for genetic capture-mark-recapture applications. Due to high degradation rates of genetic material in scat, large numbers of samples must be collected to generate robust estimates. Optimization of sampling approaches to account for taxa-specific patterns of scat deposition is, therefore, necessary to ensure sufficient sample collection. While scat collection methods have been widely studied in carnivores, research to maximize scat collection and noninvasive sampling efficiency for social ungulates is lacking. Further, environmental factors or scat morphology may influence detection of scat by observers. We contrasted performance of novel radial search protocols with existing adaptive cluster sampling protocols to quantify differences in observed amounts of wild pig (Sus scrofa) scat. We also evaluated the effects of environmental (percentage of vegetative ground cover and occurrence of rain immediately prior to sampling) and scat characteristics (fecal pellet size and number) on the detectability of scat by observers. We found that 15- and 20-m radial search protocols resulted in greater numbers of scats encountered than the previously used adaptive cluster sampling approach across habitat types, and that fecal pellet size, number of fecal pellets, percent vegetative ground cover, and recent rain events were significant predictors of scat detection. Our results suggest that use of a fixed-width radial search protocol may increase the number of scats detected for wild pigs, or other social ungulates, allowing more robust estimation of population metrics using noninvasive genetic sampling methods. Further, as fecal pellet size affected scat detection, juvenile or smaller-sized animals may be less detectable than adult or large animals, which could introduce bias into abundance estimates. Knowledge of relationships between environmental variables and scat detection may allow researchers to optimize sampling protocols to maximize utility of noninvasive sampling for wild pigs and other social ungulates.
Keiter, David A; Cunningham, Fred L; Rhodes, Olin E; Irwin, Brian J; Beasley, James C
2016-01-01
Collection of scat samples is common in wildlife research, particularly for genetic capture-mark-recapture applications. Due to high degradation rates of genetic material in scat, large numbers of samples must be collected to generate robust estimates. Optimization of sampling approaches to account for taxa-specific patterns of scat deposition is, therefore, necessary to ensure sufficient sample collection. While scat collection methods have been widely studied in carnivores, research to maximize scat collection and noninvasive sampling efficiency for social ungulates is lacking. Further, environmental factors or scat morphology may influence detection of scat by observers. We contrasted performance of novel radial search protocols with existing adaptive cluster sampling protocols to quantify differences in observed amounts of wild pig (Sus scrofa) scat. We also evaluated the effects of environmental (percentage of vegetative ground cover and occurrence of rain immediately prior to sampling) and scat characteristics (fecal pellet size and number) on the detectability of scat by observers. We found that 15- and 20-m radial search protocols resulted in greater numbers of scats encountered than the previously used adaptive cluster sampling approach across habitat types, and that fecal pellet size, number of fecal pellets, percent vegetative ground cover, and recent rain events were significant predictors of scat detection. Our results suggest that use of a fixed-width radial search protocol may increase the number of scats detected for wild pigs, or other social ungulates, allowing more robust estimation of population metrics using noninvasive genetic sampling methods. Further, as fecal pellet size affected scat detection, juvenile or smaller-sized animals may be less detectable than adult or large animals, which could introduce bias into abundance estimates. Knowledge of relationships between environmental variables and scat detection may allow researchers to optimize sampling protocols to maximize utility of noninvasive sampling for wild pigs and other social ungulates.
An Organic Decontamination Method for Sampling Devices used in Life-detection Studies
NASA Technical Reports Server (NTRS)
Eigenbrode, Jennifer; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E.F.
2008-01-01
Organic decontamination of sampling and storage devices are crucial steps for life-detection, habitability, and ecological investigations of extremophiles living in the most inhospitable niches of Earth, Mars and elsewhere. However, one of the main stumbling blocks for Mars-analogue life-detection studies in terrestrial remote field-sites is the capability to clean instruments and sampling devices to organic levels consistent with null values. Here we present a new seven-step, multi-reagent cleaning and decontamination protocol that was adapted and tested on a glacial ice-coring device and on a rover-guided scoop used for sediment sampling both deployed multiple times during two field seasons of the Arctic Mars Analog Svalbard Expedition AMASE). The effectiveness of the protocols for both devices was tested by (1)in situ metabolic measurements via APT, (2)in situ lipopolysacchride (LPS) quantifications via low-level endotoxin assays, and(3) laboratory-based molecular detection via gas chromatography-mass spectrometry. Our results show that the combination and step-wise application of disinfectants with oxidative and solvation properties for sterilization are effective at removing cellular remnants and other organic traces to levels necessary for molecular organic- and life-detection studies. The validation of this seven-step protocol - specifically for ice sampling - allows us to proceed with confidence in kmskia4 analogue investigations of icy environments. However, results from a rover scoop test showed that this protocol is also suitable for null-level decontamination of sample acquisition devices. Thus, this protocol may be applicable to a variety of sampling devices and analytical instrumentation used for future astrobiology missions to Enceladus, and Europa, as well as for sample-return missions.
Non-wadeable rivers have been largely overlooked by bioassessment programs because of sampling difficulties and a lack of appropriate methods and biological indicators. We are in the process of developing a Large River Bioassessment Protocol (LR-BP) for sampling macroinvertebrat...
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--LIST OF STANDARD OPERATING PROCEDURES
This document lists available protocols and SOPs for the U.S.-Mexico Border Program study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assuranc...
21 CFR 660.46 - Samples; protocols; official release.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Samples; protocols; official release. 660.46 Section 660.46 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface...
Ferreira, Angélica B.; Ribeiro, Andreza P.; Ferreira, Maurício L.; Kniess, Cláudia T.; Quaresma, Cristiano C.; Lafortezza, Raffaele; Santos, José O.; Saiki, Mitiko; Saldiva, Paulo H.
2017-01-01
Industrialization in developing countries associated with urban growth results in a number of economic benefits, especially in small or medium-sized cities, but leads to a number of environmental and public health consequences. This problem is further aggravated when adequate infrastructure is lacking to monitor the environmental impacts left by industries and refineries. In this study, a new protocol was designed combining biomonitoring and geostatistics to evaluate the possible effects of shale industry emissions on human health and wellbeing. Futhermore, the traditional and expensive air quality method based on PM2.5 measuring was also used to validate the low-cost geostatistical approach. Chemical analysis was performed using Energy Dispersive X-ray Fluorescence Spectrometer (EDXRF) to measure inorganic elements in tree bark and shale retorted samples in São Mateus do Sul city, Southern Brazil. Fe, S, and Si were considered potential pollutants in the study area. Distribution maps of element concentrations were generated from the dataset and used to estimate the spatial behavior of Fe, S, and Si and the range from their hot spot(s), highlighting the regions sorrounding the shale refinery. This evidence was also demonstrated in the measurements of PM2.5 concentrations, which are in agreement with the information obtained from the biomonitoring and geostatistical model. Factor and descriptive analyses performed on the concentrations of tree bark contaminants suggest that Fe, S, and Si might be used as indicators of industrial emissions. The number of cases of respiratory diseases obtained from local basic health unit were used to assess a possible correlation between shale refinery emissions and cases of repiratory disease. These data are public and may be accessed on the website of the the Brazilian Ministry of Health. Significant associations were found between the health data and refinery activities. The combination of the spatial characterization of air pollution and clinical health data revealed that adverse effects were significant for individuals over 38 years of age. These results also suggest that a protocol designed to monitor urban air quality may be an effective and low-cost strategy in environmentally contaminated cities, especially in low- and middle-income countries. PMID:28979271
Optimization of a Sample Processing Protocol for Recovery of ...
Journal Article Following a release of Bacillus anthracis spores into the environment, there is a potential for lasting environmental contamination in soils. There is a need for detection protocols for B. anthracis in environmental matrices. However, identification of B. anthracis within a soil is a difficult task. Processing soil samples helps to remove debris, chemical components, and biological impurities that can interfere with microbiological detection. This study aimed to optimize a previously used indirect processing protocol, which included a series of washing and centrifugation steps.
Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.
Mullins, Garrett R; Bruns, David E
2017-10-01
Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Přibylová, Petra; Vojta, Šimon; Kohoutek, Jiří; Lammel, Gerhard; Klánová, Jana
2017-10-01
Degradation of semivolatile organic compounds (SVOCs) occurs naturally in ambient air due to reactions with reactive trace gases (e.g., ozone, NOx). During air sampling there is also the possibility for degradation of SVOCs within the air sampler, leading to underestimates of ambient air concentrations. We investigated the possibility of this sampling artifact in commonly used active and passive air samplers for seven classes of SVOCs, including persistent organic pollutants (POPs) typically covered by air monitoring programs, as well as SVOCs of emerging concern. Two active air samplers were used, one equipped with an ozone denuder and one without, to compare relative differences in mass of collected compounds. Two sets of passive samplers were also deployed to determine the influence of degradation during longer deployment times in passive sampling. In active air samplers, comparison of the two sampling configurations suggested degradation of particle-bound polycyclic aromatic hydrocarbons (PAHs), with concentrations up to 2× higher in the denuder-equipped sampler, while halogenated POPs did not have clear evidence of degradation. In contrast, more polar, reactive compounds (e.g., organophosphate esters and current use pesticides) had evidence of losses in the sampler with denuder. This may be caused by the denuder itself, suggesting sampling bias for these compounds can be created when typical air sampling apparatuses are adapted to limit degradation. Passive air samplers recorded up to 4× higher concentrations when deployed for shorter consecutive sampling periods, suggesting that within-sampler degradation may also be relevant in passive air monitoring programs.
Metabolic profiling of body fluids and multivariate data analysis.
Trezzi, Jean-Pierre; Jäger, Christian; Galozzi, Sara; Barkovits, Katalin; Marcus, Katrin; Mollenhauer, Brit; Hiller, Karsten
2017-01-01
Metabolome analyses of body fluids are challenging due pre-analytical variations, such as pre-processing delay and temperature, and constant dynamical changes of biochemical processes within the samples. Therefore, proper sample handling starting from the time of collection up to the analysis is crucial to obtain high quality samples and reproducible results. A metabolomics analysis is divided into 4 main steps: 1) Sample collection, 2) Metabolite extraction, 3) Data acquisition and 4) Data analysis. Here, we describe a protocol for gas chromatography coupled to mass spectrometry (GC-MS) based metabolic analysis for biological matrices, especially body fluids. This protocol can be applied on blood serum/plasma, saliva and cerebrospinal fluid (CSF) samples of humans and other vertebrates. It covers sample collection, sample pre-processing, metabolite extraction, GC-MS measurement and guidelines for the subsequent data analysis. Advantages of this protocol include: •Robust and reproducible metabolomics results, taking into account pre-analytical variations that may occur during the sampling process•Small sample volume required•Rapid and cost-effective processing of biological samples•Logistic regression based determination of biomarker signatures for in-depth data analysis.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-03
... Collection; Comment Request; Protocol for Access to Tissue Specimen Samples From the National Marine Mammal Tissue Bank AGENCY: National Oceanic and Atmospheric Administration (NOAA), Commerce. ACTION: Notice... National Marine Mammal Tissue Bank (NMMTB) was established by the National Marine Fisheries Service (NMFS...
Development of reagents for immunoassay of Phytophthora ramorum in nursery water samples
Douglas G. Luster; Timothy Widmer; Michael McMahon; C. André Lévesque
2017-01-01
Current regulations under the August 6, 2014 USDA APHIS Official Regulatory Protocol (Confirmed Nursery Protocol: Version 8.2) for Nurseries Containing Plants Infected with Phytophthora ramorum mandates the sampling of water in affected nurseries to demonstrate they are free of P. ramorum. Currently, detection of
A MORE COST-EFFECTIVE EMAP BENTHIC MACROFAUNAL SAMPLING PROTOCOL
Benthic macrofaunal sampling protocols in the U.S. Environmental Protection Agency's Environmental Monitoring and Assessment Program (EMAP) are to collect 30 to 50 random benthic macrofauna [defined as animals retained on a 0.5 mm (East and Gulf Coasts, USA) or a 1.0 mm mesh siev...
21 CFR 660.6 - Samples; protocols; official release.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Research, determines that the reliability and consistency of the finished product can be assured with a... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Samples; protocols; official release. 660.6 Section 660.6 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...
21 CFR 660.6 - Samples; protocols; official release.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Research, determines that the reliability and consistency of the finished product can be assured with a... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Samples; protocols; official release. 660.6 Section 660.6 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...
STANDARD MEASUREMENT PROTOCOLS - FLORIDA RADON RESEARCH PROGRAM
The manual, in support of the Florida Radon Research Program, contains standard protocols for key measurements where data quality is vital to the program. t contains two sections. he first section, soil measurements, contains field sampling protocols for soil gas permeability and...
6.6-hour inhalation of ozone concentrations from 60 to 87 parts per billion in healthy humans.
Schelegle, Edward S; Morales, Christopher A; Walby, William F; Marion, Susan; Allen, Roblee P
2009-08-01
Identification of the minimal ozone (O(3)) concentration and/or dose that induces measurable lung function decrements in humans is considered in the risk assessment leading to establishing an appropriate National Ambient Air Quality Standard for O(3) that protects public health. To identify and/or predict the minimal mean O(3) concentration that produces a decrement in FEV(1) and symptoms in healthy individuals completing 6.6-hour exposure protocols. Pulmonary function and subjective symptoms were measured in 31 healthy adults (18-25 yr, male and female, nonsmokers) who completed five 6.6-hour chamber exposures: filtered air and four variable hourly patterns with mean O(3) concentrations of 60, 70, 80, and 87 parts per billion (ppb). Compared with filtered air, statistically significant decrements in FEV(1) and increases in total subjective symptoms scores (P < 0.05) were measured after exposure to mean concentrations of 70, 80, and 87 ppb O(3). The mean percent change in FEV(1) (+/-standard error) at the end of each protocol was 0.80 +/- 0.90, -2.72 +/- 1.48, -5.34 +/- 1.42, -7.02 +/- 1.60, and -11.42 +/- 2.20% for exposure to filtered air and 60, 70, 80, and 87 ppb O(3), respectively. Inhalation of 70 ppb O(3) for 6.6 hours, a concentration below the current 8-hour National Ambient Air Quality Standard of 75 ppb, is sufficient to induce statistically significant decrements in FEV(1) in healthy young adults.
A novel method of genomic DNA extraction for Cactaceae1
Fehlberg, Shannon D.; Allen, Jessica M.; Church, Kathleen
2013-01-01
• Premise of the study: Genetic studies of Cactaceae can at times be impeded by difficult sampling logistics and/or high mucilage content in tissues. Simplifying sampling and DNA isolation through the use of cactus spines has not previously been investigated. • Methods and Results: Several protocols for extracting DNA from spines were tested and modified to maximize yield, amplification, and sequencing. Sampling of and extraction from spines resulted in a simplified protocol overall and complete avoidance of mucilage as compared to typical tissue extractions. Sequences from one nuclear and three plastid regions were obtained across eight genera and 20 species of cacti using DNA extracted from spines. • Conclusions: Genomic DNA useful for amplification and sequencing can be obtained from cactus spines. The protocols described here are valuable for any cactus species, but are particularly useful for investigators interested in sampling living collections, extensive field sampling, and/or conservation genetic studies. PMID:25202521
Group Centric Networking: Large Scale Over the Air Testing of Group Centric Networking
2016-11-01
protocol designed to support groups of devices in a local region [4]. It attempts to use the wireless medium to broadcast minimal control information...1) Group Discovery: The goal of the group discovery algo- rithm is to find group nodes without globally flooding control messages. To facilitate this...Large Scale Over-the-Air Testing of Group Centric Networking Logan Mercer, Greg Kuperman, Andrew Hunter, Brian Proulx MIT Lincoln Laboratory
Havens, Deborah; Jary, Hannah R; Patel, Latifa B; Chiume, Msandeni E; Mortimer, Kevin J
2015-01-01
This is the protocol for a review and there is no abstract. The objectives are as follows: This study aims to assess the effects of intervention strategies that reduce exposure to household air pollution from burning solid fuels on episodes of acute lower respiratory infection (ALRI) in children under the age of 15 years.
Kopek, Benjamin G.; Paez-Segala, Maria G.; Shtengel, Gleb; Sochacki, Kem A.; Sun, Mei G.; Wang, Yalin; Xu, C. Shan; van Engelenburg, Schuyler B.; Taraska, Justin W.; Looger, Loren L.; Hess, Harald F.
2017-01-01
Our groups have recently developed related approaches for sample preparation for super-resolution imaging within endogenous cellular environments using correlative light and electron microscopy (CLEM). Four distinct techniques for preparing and acquiring super-resolution CLEM datasets on aldehyde-fixed specimens are provided, including Tokuyasu cryosectioning, whole-cell mount, cell unroofing and platinum replication, and resin embedding and sectioning. Choice of the best protocol for a given application depends on a number of criteria that are discussed in detail. Tokuyasu cryosectioning is relatively rapid but is limited to small, delicate specimens. Whole-cell mount has the simplest sample preparation but is restricted to surface structures. Cell unroofing and platinum replica creates high-contrast, 3-dimensional images of the cytoplasmic surface of the plasma membrane, but is more challenging than whole-cell mount. Resin embedding permits serial sectioning of large samples, but is limited to osmium-resistant probes, and is technically difficult. Expected results from these protocols include super-resolution localization (~10–50 nm) of fluorescent targets within the context of electron microscopy ultrastructure, which can help address cell biological questions. These protocols can be completed in 2–7 days, are compatible with a number of super-resolution imaging protocols, and are broadly applicable across biology. PMID:28384138
A rapid and efficient DNA extraction protocol from fresh and frozen human blood samples.
Guha, Pokhraj; Das, Avishek; Dutta, Somit; Chaudhuri, Tapas Kumar
2018-01-01
Different methods available for extraction of human genomic DNA suffer from one or more drawbacks including low yield, compromised quality, cost, time consumption, use of toxic organic solvents, and many more. Herein, we aimed to develop a method to extract DNA from 500 μL of fresh or frozen human blood. Five hundred microliters of fresh and frozen human blood samples were used for standardization of the extraction procedure. Absorbance at 260 and 280 nm, respectively, (A 260 /A 280 ) were estimated to check the quality and quantity of the extracted DNA sample. Qualitative assessment of the extracted DNA was checked by Polymerase Chain reaction and double digestion of the DNA sample. Our protocol resulted in average yield of 22±2.97 μg and 20.5±3.97 μg from 500 μL of fresh and frozen blood, respectively, which were comparable to many reference protocols and kits. Besides yielding bulk amount of DNA, our protocol is rapid, economical, and avoids toxic organic solvents such as Phenol. Due to unaffected quality, the DNA is suitable for downstream applications. The protocol may also be useful for pursuing basic molecular researches in laboratories having limited funds. © 2017 Wiley Periodicals, Inc.
Use of a Filter Cartridge for Filtration of Water Samples and Extraction of Environmental DNA.
Miya, Masaki; Minamoto, Toshifumi; Yamanaka, Hiroki; Oka, Shin-Ichiro; Sato, Keiichi; Yamamoto, Satoshi; Sado, Tetsuya; Doi, Hideyuki
2016-11-25
Recent studies demonstrated the use of environmental DNA (eDNA) from fishes to be appropriate as a non-invasive monitoring tool. Most of these studies employed disk fiber filters to collect eDNA from water samples, although a number of microbial studies in aquatic environments have employed filter cartridges, because the cartridge has the advantage of accommodating large water volumes and of overall ease of use. Here we provide a protocol for filtration of water samples using the filter cartridge and extraction of eDNA from the filter without having to cut open the housing. The main portions of this protocol consists of 1) filtration of water samples (water volumes ≤4 L or >4 L); (2) extraction of DNA on the filter using a roller shaker placed in a preheated incubator; and (3) purification of DNA using a commercial kit. With the use of this and previously-used protocols, we perform metabarcoding analysis of eDNA taken from a huge aquarium tank (7,500 m 3 ) with known species composition, and show the number of detected species per library from the two protocols as the representative results. This protocol has been developed for metabarcoding eDNA from fishes, but is also applicable to eDNA from other organisms.
Nagy, Bálint; Bán, Zoltán; Papp, Zoltán
2005-10-01
The quality and the quantity of isolated DNA have an effect on PCR amplifications. The authors studied three DNA isolation protocols (resin binding method using fresh and frozen amniotic fluid samples, and silica adsorption method using fresh samples) on the quantity and on the quality of the isolated DNA. Amniotic fluid samples were obtained from 20 pregnant women. The isolated DNA concentrations were determined by real-time fluorimeter using SYBRGreen I method. Each sample was studied for the presence of 8 STR markers. The authors compared the number of the detected alleles, electrophoretograms and peak areas. There was a significant difference between the concentration of the obtained DNA and in the peak areas between the three isolation protocols. The numbers of detected alleles were different, we observed the most allele drop outs in the resin type DNA isolation protocol from the fresh sample (detected allele numbers 182), followed by resin binding protocol from the frozen samples (detected allele number 243) and by the silica adsorption method (detected allele number 264). The authors demonstrated that the DNA isolation method has an effect on the quantity and quality of the isolated DNA, and on further PCR amplifications.
Validating Analytical Protocols to Determine Selected Pesticides and PCBs Using Routine Samples.
Pindado Jiménez, Oscar; García Alonso, Susana; Pérez Pastor, Rosa María
2017-01-01
This study aims at providing recommendations concerning the validation of analytical protocols by using routine samples. It is intended to provide a case-study on how to validate the analytical methods in different environmental matrices. In order to analyze the selected compounds (pesticides and polychlorinated biphenyls) in two different environmental matrices, the current work has performed and validated two analytical procedures by GC-MS. A description is given of the validation of the two protocols by the analysis of more than 30 samples of water and sediments collected along nine months. The present work also scopes the uncertainty associated with both analytical protocols. In detail, uncertainty of water sample was performed through a conventional approach. However, for the sediments matrices, the estimation of proportional/constant bias is also included due to its inhomogeneity. Results for the sediment matrix are reliable, showing a range 25-35% of analytical variability associated with intermediate conditions. The analytical methodology for the water matrix determines the selected compounds with acceptable recoveries and the combined uncertainty ranges between 20 and 30%. Analyzing routine samples is rarely applied to assess trueness of novel analytical methods and up to now this methodology was not focused on organochlorine compounds in environmental matrices.
Rozenberg, Andrey; Leese, Florian; Weiss, Linda C; Tollrian, Ralph
2016-01-01
Tag-Seq is a high-throughput approach used for discovering SNPs and characterizing gene expression. In comparison to RNA-Seq, Tag-Seq eases data processing and allows detection of rare mRNA species using only one tag per transcript molecule. However, reduced library complexity raises the issue of PCR duplicates, which distort gene expression levels. Here we present a novel Tag-Seq protocol that uses the least biased methods for RNA library preparation combined with a novel approach for joint PCR template and sample labeling. In our protocol, input RNA is fragmented by hydrolysis, and poly(A)-bearing RNAs are selected and directly ligated to mixed DNA-RNA P5 adapters. The P5 adapters contain i5 barcodes composed of sample-specific (moderately) degenerate base regions (mDBRs), which later allow detection of PCR duplicates. The P7 adapter is attached via reverse transcription with individual i7 barcodes added during the amplification step. The resulting libraries can be sequenced on an Illumina sequencer. After sample demultiplexing and PCR duplicate removal with a free software tool we designed, the data are ready for downstream analysis. Our protocol was tested on RNA samples from predator-induced and control Daphnia microcrustaceans.
Crystallization of Macromolecules
Friedmann, David; Messick, Troy; Marmorstein, Ronen
2014-01-01
X-ray crystallography has evolved into a very powerful tool to determine the three-dimensional structure of macromolecules and macromolecular complexes. The major bottleneck in structure determination by X-ray crystallography is the preparation of suitable crystalline samples. This unit outlines steps for the crystallization of a macromolecule, starting with a purified, homogeneous sample. The first protocols describe preparation of the macromolecular sample (i.e., proteins, nucleic acids, and macromolecular complexes). The preparation and assessment of crystallization trials is then described, along with a protocol for confirming whether the crystals obtained are composed of macromolecule as opposed to a crystallization reagent . Next, the optimization of crystallization conditions is presented. Finally, protocols that facilitate the growth of larger crystals through seeding are described. PMID:22045560
Palacio-Bielsa, Ana; Cubero, Jaime; Cambra, Miguel A; Collados, Raquel; Berruete, Isabel M; López, María M
2011-01-01
Xanthomonas arboricola pv. pruni, the causal agent of bacterial spot disease of stone fruit, is considered a quarantine organism by the European Union and the European and Mediterranean Plant Protection Organization (EPPO). The bacterium can undergo an epiphytic phase and/or be latent and can be transmitted by plant material, but currently, only visual inspections are used to certify plants as being X. arboricola pv. pruni free. A novel and highly sensitive real-time TaqMan PCR detection protocol was designed based on a sequence of a gene for a putative protein related to an ABC transporter ATP-binding system in X. arboricola pv. pruni. Pathogen detection can be completed within a few hours with a sensitivity of 10(2) CFU ml(-1), thus surpassing the sensitivity of the existing conventional PCR. Specificity was assessed for X. arboricola pv. pruni strains from different origins as well as for closely related Xanthomonas species, non-Xanthomonas species, saprophytic bacteria, and healthy Prunus samples. The efficiency of the developed protocol was evaluated with field samples of 14 Prunus species and rootstocks. For symptomatic leaf samples, the protocol was very efficient even when washed tissues of the leaves were directly amplified without any previous DNA extraction. For samples of 117 asymptomatic leaves and 285 buds, the protocol was more efficient after a simple DNA extraction, and X. arboricola pv. pruni was detected in 9.4% and 9.1% of the 402 samples analyzed, respectively, demonstrating its frequent epiphytic or endophytic phase. This newly developed real-time PCR protocol can be used as a quantitative assay, offers a reliable and sensitive test for X. arboricola pv. pruni, and is suitable as a screening test for symptomatic as well as asymptomatic plant material.
Consensus for second-order multi-agent systems with position sampled data
NASA Astrophysics Data System (ADS)
Wang, Rusheng; Gao, Lixin; Chen, Wenhai; Dai, Dameng
2016-10-01
In this paper, the consensus problem with position sampled data for second-order multi-agent systems is investigated. The interaction topology among the agents is depicted by a directed graph. The full-order and reduced-order observers with position sampled data are proposed, by which two kinds of sampled data-based consensus protocols are constructed. With the provided sampled protocols, the consensus convergence analysis of a continuous-time multi-agent system is equivalently transformed into that of a discrete-time system. Then, by using matrix theory and a sampled control analysis method, some sufficient and necessary consensus conditions based on the coupling parameters, spectrum of the Laplacian matrix and sampling period are obtained. While the sampling period tends to zero, our established necessary and sufficient conditions are degenerated to the continuous-time protocol case, which are consistent with the existing result for the continuous-time case. Finally, the effectiveness of our established results is illustrated by a simple simulation example. Project supported by the Natural Science Foundation of Zhejiang Province, China (Grant No. LY13F030005) and the National Natural Science Foundation of China (Grant No. 61501331).
Robust DNA Isolation and High-throughput Sequencing Library Construction for Herbarium Specimens.
Saeidi, Saman; McKain, Michael R; Kellogg, Elizabeth A
2018-03-08
Herbaria are an invaluable source of plant material that can be used in a variety of biological studies. The use of herbarium specimens is associated with a number of challenges including sample preservation quality, degraded DNA, and destructive sampling of rare specimens. In order to more effectively use herbarium material in large sequencing projects, a dependable and scalable method of DNA isolation and library preparation is needed. This paper demonstrates a robust, beginning-to-end protocol for DNA isolation and high-throughput library construction from herbarium specimens that does not require modification for individual samples. This protocol is tailored for low quality dried plant material and takes advantage of existing methods by optimizing tissue grinding, modifying library size selection, and introducing an optional reamplification step for low yield libraries. Reamplification of low yield DNA libraries can rescue samples derived from irreplaceable and potentially valuable herbarium specimens, negating the need for additional destructive sampling and without introducing discernible sequencing bias for common phylogenetic applications. The protocol has been tested on hundreds of grass species, but is expected to be adaptable for use in other plant lineages after verification. This protocol can be limited by extremely degraded DNA, where fragments do not exist in the desired size range, and by secondary metabolites present in some plant material that inhibit clean DNA isolation. Overall, this protocol introduces a fast and comprehensive method that allows for DNA isolation and library preparation of 24 samples in less than 13 h, with only 8 h of active hands-on time with minimal modifications.
An optimised protocol for molecular identification of Eimeria from chickens☆
Kumar, Saroj; Garg, Rajat; Moftah, Abdalgader; Clark, Emily L.; Macdonald, Sarah E.; Chaudhry, Abdul S.; Sparagano, Olivier; Banerjee, Partha S.; Kundu, Krishnendu; Tomley, Fiona M.; Blake, Damer P.
2014-01-01
Molecular approaches supporting identification of Eimeria parasites infecting chickens have been available for more than 20 years, although they have largely failed to replace traditional measures such as microscopy and pathology. Limitations of microscopy-led diagnostics, including a requirement for specialist parasitological expertise and low sample throughput, are yet to be outweighed by the difficulties associated with accessing genomic DNA from environmental Eimeria samples. A key step towards the use of Eimeria species-specific PCR as a sensitive and reproducible discriminatory tool for use in the field is the production of a standardised protocol that includes sample collection and DNA template preparation, as well as primer selection from the numerous PCR assays now published. Such a protocol will facilitate development of valuable epidemiological datasets which may be easily compared between studies and laboratories. The outcome of an optimisation process undertaken in laboratories in India and the UK is described here, identifying four steps. First, samples were collected into a 2% (w/v) potassium dichromate solution. Second, oocysts were enriched by flotation in saturated saline. Third, genomic DNA was extracted using a QIAamp DNA Stool mini kit protocol including a mechanical homogenisation step. Finally, nested PCR was carried out using previously published primers targeting the internal transcribed spacer region 1 (ITS-1). Alternative methods tested included sample processing in the presence of faecal material, DNA extraction using a traditional phenol/chloroform protocol, the use of SCAR multiplex PCR (one tube and two tube versions) and speciation using the morphometric tool COCCIMORPH for the first time with field samples. PMID:24138724
Development of an HPV Educational Protocol for Adolescents
Wetzel, Caitlin; Tissot, Abbigail; Kollar, Linda M.; Hillard, Paula A.; Stone, Rachel; Kahn, Jessica A.
2007-01-01
Study Objectives To develop an educational protocol about HPV and Pap tests for adolescents, to evaluate the protocol for understandability and clarity, and to evaluate the protocol for its effectiveness in increasing knowledge about HPV. Design In phase 1, investigators and adolescents developed the protocol. In phase 2, adolescents evaluated the protocol qualitatively, investigators evaluated its effectiveness in increasing HPV knowledge in a sample of adolescents, and the protocol was revised. In phase 3, investigators evaluated the effectiveness of the revised protocol in an additional adolescent sample. Setting Urban, hospital-based teen health center. Participants A total of 252 adolescent girls and boys in the three study phases. Main Outcome Measures Pre- and post-protocol knowledge about HPV, measured using a 10- or 11-item scale. Results Scores on the HPV knowledge scale increased significantly (p<.0001) among adolescents who participated in phases 2 and 3 after they received the protocol. Initial differences in scores based on race, insurance type and condom use were not noted post-protocol. Conclusion The protocol significantly increased knowledge scores about HPV in this population, regardless of sociodemographic characteristics and risk behaviors. Effective, developmentally appropriate educational protocols about HPV and Pap tests are particularly important in clinical settings as cervical cancer screening guidelines evolve, HPV DNA testing is integrated into screening protocols, and HPV vaccines become available. In-depth, one-on-one education about HPV may also prevent adverse psychosocial responses and promote healthy sexual and Pap screening behaviors in adolescents with abnormal HPV or Pap test results. Synopsis The investigators developed an educational protocol about HPV and Pap tests and evaluated its effectiveness in increasing knowledge about HPV among adolescents. PMID:17868894
Optimization of a sample processing protocol for recovery of Bacillus anthracis spores from soil
Silvestri, Erin E.; Feldhake, David; Griffin, Dale; Lisle, John T.; Nichols, Tonya L.; Shah, Sanjiv; Pemberton, A; Schaefer III, Frank W
2016-01-01
Following a release of Bacillus anthracis spores into the environment, there is a potential for lasting environmental contamination in soils. There is a need for detection protocols for B. anthracis in environmental matrices. However, identification of B. anthracis within a soil is a difficult task. Processing soil samples helps to remove debris, chemical components, and biological impurities that can interfere with microbiological detection. This study aimed to optimize a previously used indirect processing protocol, which included a series of washing and centrifugation steps. Optimization of the protocol included: identifying an ideal extraction diluent, variation in the number of wash steps, variation in the initial centrifugation speed, sonication and shaking mechanisms. The optimized protocol was demonstrated at two laboratories in order to evaluate the recovery of spores from loamy and sandy soils. The new protocol demonstrated an improved limit of detection for loamy and sandy soils over the non-optimized protocol with an approximate matrix limit of detection at 14 spores/g of soil. There were no significant differences overall between the two laboratories for either soil type, suggesting that the processing protocol will be robust enough to use at multiple laboratories while achieving comparable recoveries.
NASA Astrophysics Data System (ADS)
McDougald, Wendy A.; Collins, Richard; Green, Mark; Tavares, Adriana A. S.
2017-10-01
Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT) imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1) to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2) to evaluate the absorbed dose associated with varying CT parameters. Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA) software implemented by Mediso. Measured Hounsfield Unit (HU) in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC), uniformity and quantitative bias were also measured. Results: Only less than 2% and 1% of CT acquisition protocols yielded water HU values < -80 and air HU values < -840, respectively. Four out of eleven CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration. Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed towards improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.
NASA Astrophysics Data System (ADS)
Smith, S. R.; Rolph, J.; Briggs, K.; Elya, J. L.; Bourassa, M. A.
2016-02-01
The authors will describe the successes and lessons learned from the Shipboard Automated Meteorological and Oceanographic System (SAMOS) initiative. Over the past decade, SAMOS has acquired, quality controlled, and distributed underway surface meteorological and oceanographic observations from nearly 40 oceanographic research vessels. Research vessels provide underway observations at high-temporal frequency (1-minute sampling interval) that include navigational (position, course, heading, and speed), meteorological (air temperature, humidity, wind, surface pressure, radiation, rainfall), and oceanographic (surface sea temperature and salinity) samples. Vessels recruited to the SAMOS initiative collect a high concentration of data within the U.S. continental shelf, around Hawaii and the islands of the tropical Pacific, and frequently operate well outside routine shipping lanes, capturing observations in extreme ocean environments (Southern, Arctic, South Atlantic, and South Pacific oceans) desired by the air-sea exchange, modeling, and satellite remote sensing communities. The presentation will highlight the data stewardship practices of the SAMOS initiative. Activities include routine automated and visual data quality evaluation, feedback to vessel technicians and operators regarding instrumentation errors, best practices for instrument siting and exposure on research vessels, and professional development activities for research vessel technicians. Best practices for data, metadata, and quality evaluation will be presented. We will discuss ongoing efforts to expand data services to enhance interoperability between marine data centers. Data access and archival protocols will also be presented, including how these data may be referenced and accessed via NCEI.
Use of Capillaries for Macromolecular Crystallization in a Cryogenic Dewar
NASA Technical Reports Server (NTRS)
Ciszak, Ewa; Hammons, Aaron S.; Hong, Young Soo
2002-01-01
The enhanced gaseous nitrogen (EGN) dewar is a cryogenic dry shipper with a sealed cylinder inserted inside along with a temperature monitoring device, and is intended for macromolecular crystallization experiments on the International Space Station. Within the dewar, each crystallization experiment is contained as a solution within a plastic capillary tube. The standard procedure for loading samples in these tubes has involved rapid freezing of the precipitant and biomolecular solution, e.g., protein, directly in liquid nitrogen; this method, however, often resulted in uncontrolled formation of air voids, These air pockets, or bubbles, can lead to irreproducible crystallization results. A novel protocol has been developed to prevent formation of bubbles, and this has been tested in the laboratory as well as aboard the International Space Station during a 42-day long mission of July/August 2001. The gain or loss of mass from solutions within the plastic capillaries revealed that mass transport occurred among separated tubes, and that this mass transport was dependent upon the hygroscopic character of the solution contained in any given tube. The surface area of the plastic capillary tube also related to the observed mass transport. Furthermore, the decreased mass of solutions of-protein correlated to observed formation of protein crystals.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Air sampling. 61.34 Section 61.34... sampling. (a) Stationary sources subject to § 61.32(b) shall locate air sampling sites in accordance with a... concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...
Tran, Duc T; Banerjee, Sambuddha; Alayash, Abdu I; Crumbliss, Alvin L; Fitzgerald, Michael C
2012-02-07
Described here is a mass spectrometry-based protocol to study the thermodynamic stability of proteins and protein-ligand complexes using the chemical denaturant dependence of the slow H/D exchange reaction of the imidazole C(2) proton in histidine side chains. The protocol is developed using several model protein systems including: ribonuclease (Rnase) A, myoglobin, bovine carbonic anhydrase (BCA) II, hemoglobin (Hb), and the hemoglobin-haptoglobin (Hb-Hp) protein complex. Folding free energies consistent with those previously determined by other more conventional techniques were obtained for the two-state folding proteins, Rnase A and myoglobin. The protocol successfully detected a previously observed partially unfolded intermediate stabilized in the BCA II folding/unfolding reaction, and it could be used to generate a K(d) value of 0.24 nM for the Hb-Hp complex. The compatibility of the protocol with conventional mass spectrometry-based proteomic sample preparation and analysis methods was also demonstrated in an experiment in which the protocol was used to detect the binding of zinc to superoxide dismutase in the yeast cell lysate sample. The yeast cell sample analyses also helped define the scope of the technique, which requires the presence of globally protected histidine residues in a protein's three-dimensional structure for successful application. © 2011 American Chemical Society
Carretero, M I; Giuliano, S M; Arraztoa, C C; Santa Cruz, R C; Fumuso, F G; Neild, D M
2017-08-01
Seminal plasma (SP) of South American Camelids could interfere with the interaction of spermatozoa with the extenders; therefore it becomes necessary to improve semen management using enzymatic treatment. Our objective was to compare two cooling protocols for llama semen. Twelve ejaculates were incubated in 0.1% collagenase and then were divided into two aliquots. One was extended in lactose and egg yolk (LEY) (Protocol A: collagenase and SP present). The other aliquot was centrifuged, and the pellet was resuspended in LEY (Protocol B: collagenase and SP absent). Both samples were maintained at 5°C during 24 hr. Routine and DNA evaluations were carried out in raw and cooled semen. Both cooling protocols maintained sperm viability, membrane function and DNA fragmentation, with Protocol A showing a significantly lowered total and progressive motility (p < .05) and Protocol B showing a significant increase in chromatin decondensation (p < .05). Protocol A avoids centrifugation, reducing processing times and making application in the field simpler. However, as neither protocol showed a significant superiority over the other, studies should be carried out in vivo to evaluate the effect on pregnancy rates of the presence of collagenase and SP in semen samples prior to either cooling or freeze-thawing. © 2016 Blackwell Verlag GmbH.
Brito, Maíra M; Lúcio, Cristina F; Angrimani, Daniel S R; Losano, João Diego A; Dalmazzo, Andressa; Nichi, Marcílio; Vannucchi, Camila I
2017-01-02
In addition to the existence of several cryopreservation protocols, no systematic research has been carried out in order to confirm the suitable protocol for canine sperm. This study aims to assess the effect of adding 5% glycerol during cryopreservation at 37°C (one-step) and 5°C (two-steps), in addition of testing two thawing protocols (37°C for 30 seconds, and 70°C for 8 seconds). We used 12 sperm samples divided into four experimental groups: Single-Step - Slow Thawing Group; Two-Step - Slow Thawing Group; Single-Step - Fast Thawing Group; and Two-Step - Fast Thawing Group. Frozen-thawed samples were submitted to automated analysis of sperm motility, evaluation of plasmatic membrane integrity, acrosomal integrity, mitochondrial activity, sperm morphology, sperm susceptibility to oxidative stress, and sperm binding assay to perivitellinic membrane of chicken egg yolk. Considering the comparison between freezing protocols, no statistical differences were verified for any of the response variables. When comparison between thawing protocols was performed, slow thawing protocol presented higher sperm count bound to perivitelline membrane of chicken egg yolk, compared to fast thawing protocol. Regardless of the freezing process, the slow thawing protocol can be recommended for the large scale cryopreservation of canine semen, since it shows a consistent better functional result.
Development of bull trout sampling protocols
R. F. Thurow; J. T. Peterson; J. W. Guzevich
2001-01-01
This report describes results of research conducted in Washington in 2000 through Interagency Agreement #134100H002 between the U.S. Fish and Wildlife Service (USFWS) and the U.S. Forest Service Rocky Mountain Research Station (RMRS). The purpose of this agreement is to develop a bull trout (Salvelinus confluentus) sampling protocol by integrating...
NHEXAS PHASE I ARIZONA STUDY--METALS IN AIR ANALYTICAL RESULTS
The Metals in Air data set contains analytical results for measurements of up to 11 metals in 369 air samples over 175 households. Samples were taken by pumping standardized air volumes through filters at indoor and outdoor sites around each household being sampled. The primary...
Beamer, P.I.; Sugeng, A. J.; Kelly, M.D.; Lothrop, N.; Klimecki, W.; Wilkinson, S.T.; Loh, M.
2014-01-01
Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p<0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites. PMID:24469149
NASA Astrophysics Data System (ADS)
Lee Zhi Yi, Amelia; Dercon, Gerd; Blackburn, Carl; Kheng, Heng Lee
2017-04-01
In the event of a large-scale nuclear accident, the swift implementation of response actions is imperative. For food and agriculture, it is important to restrict contaminated food from being produced or gathered, and to put in place systems to prevent contaminated produce from entering the food chain. Emergency tools and response protocols exist to assist food control and health authorities but they tend to focus on radioactivity concentrations in food products as a means of restricting the distribution and sale of contaminated produce. Few, if any, emergency tools or protocols focus on the food production environment, for example radioactivity concentrations in soils. Here we present the Operational Intervention Levels for Soils (OIL for Soils) concept, an optimization tool developed at the IAEA to facilitate agricultural decision making and to improve nuclear emergency preparedness and response capabilities. Effective intervention relies on the prompt availability of radioactivity concentration data and the ability to implement countermeasures. Sampling in food and agriculture can be demanding because it may involve large areas and many sample types. In addition, there are finite resources available in terms of manpower and laboratory support. Consequently, there is a risk that timely decision making will be hindered and food safety compromised due to time taken to sample and analyse produce. However, the OILs for Soils concept developed based on experience in Japan can help in this situation and greatly assist authorities responsible for agricultural production. OILs for Soils - pre-determined reference levels of air dose rates linked to radionuclide concentrations in soils - can be used to trigger response actions particularly important for agricultural and food protection. Key considerations in the development of the OILs for Soils are: (1) establishing a pragmatic sampling approach to prioritize and optimize available resources and data requirements for decision making in agricultural sites: (2) creating a system that is adaptable to different countries, and; (3) developing a framework to calculate default values of OILs for Soils for application during an emergency. The OILs for Soils reference levels are calculated using a mathematical model. Empirical equations, paired with radionuclide data (e.g. Cs-134, Cs-137 and I-131) from the ICRU 53 report, are utilized to determine soil contamination from aerial monitoring air dose rate data. Modelling allows soil contamination values to be readily approximated and this is used to prioritize soil and food sampling sites. Reference levels are based on a model that considers radionuclide transfer factors for up-take into plants, soil density, and soil sampling depth. Decision actions for determined reference levels are suggested for processed foods, animal products, animal feed and crop products (including plants at the growing stage, mature stage, fallow farmland, and forestry products). With these steps, OILs for Soils provide practical guidance that will equip authorities to respond efficiently and help maintain the safety of the food supply during large-scale nuclear or radiological emergency situations.
Assessment of levels of bacterial contamination of large wild game meat in Europe.
Membré, Jeanne-Marie; Laroche, Michel; Magras, Catherine
2011-08-01
The variations in prevalence and levels of pathogens and fecal contamination indicators in large wild game meat were studied to assess their potential impact on consumers. This analysis was based on hazard analysis, data generation and statistical analysis. A total of 2919 meat samples from three species (red deer, roe deer, wild boar) were collected at French game meat traders' facilities using two sampling protocols. Information was gathered on the types of meat cuts (forequarter or haunch; first sampling protocol) or type of retail-ready meat (stewing meat or roasting meat; second protocol), and also on the meat storage conditions (frozen or chilled), country of origin (eight countries) and shooting season (autumn, winter, spring). The samples were analyzed in both protocols for detection and enumeration of Escherichia coli, coagulase+staphylococci and Clostridium perfringens. In addition, detection and enumeration of thermotolerant coliforms and Listeria monocytogenes were performed for samples collected in the first and second protocols, respectively. The levels of bacterial contamination of the raw meat were determined by performing statistical analysis involving probabilistic techniques and Bayesian inference. C. perfringens was found in the highest numbers for the three indicators of microbial quality, hygiene and good handling, and L. monocytogenes in the lowest. Differences in contamination levels between game species and between meats distributed as chilled or frozen products were not significant. These results might be included in quantitative exposure assessments. Copyright © 2011 Elsevier Ltd. All rights reserved.
Filter for on-line air monitor unaffected by radon progeny and method of using same
Phillips, Terrance D.; Edwards, Howard D.
1999-01-01
An apparatus for testing air having contaminants and radon progeny therein. The apparatus includes a sampling box having an inlet for receiving the air and an outlet for discharging the air. The sampling box includes a filter made of a plate of sintered stainless steel. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough. A method of testing air having contaminants and radon progeny therein. The method includes providing a testing apparatus that has a sampling box with an inlet for receiving the air and an outlet for discharging the air, and has a sintered stainless steel filter disposed within said sampling box; drawing air from a source into the sampling box using a vacuum pump; passing the air through the filter; monitoring the contaminants trapped by the filter; and providing an alarm when a selected level of contaminants is reached. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough.
Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat
2013-01-01
Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.
Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat
2013-01-01
Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164
Pontier, J-M; Lambrechts, K
2014-06-01
We highlighted a relationship between decompression-induced bubble formation and platelet micro-particle (PMP) release after a scuba air-dive. It is known that decompression protocol using oxygen-stop accelerates the washout of nitrogen loaded in tissues. The aim was to study the effect of oxygen deco-stop on bubble formation and cell-derived MP release. Healthy experienced divers performed two scuba-air dives to 30 msw for 30 min, one with an air deco-stop and a second with 100% oxygen deco-stop at 3 msw for 9 min. Bubble grades were monitored with ultrasound and converted to the Kisman integrated severity score (KISS). Blood samples for cell-derived micro-particle analysis (AnnexinV for PMP and CD31 for endothelial MP) were taken 1 h before and after each dive. Mean KISS bubble score was significantly lower after the dive with oxygen-decompression stop, compared to the dive with air-decompression stop (4.3 ± 7.3 vs. 32.7 ± 19.9, p < 0.001). After the dive with an air-breathing decompression stop, we observed an increase of the post-dive mean values of PMP (753 ± 245 vs. 381 ± 191 ng/μl, p = 0.003) but no significant change in the oxygen-stop decompression dive (329 ± 215 vs. 381 +/191 ng/μl, p = 0.2). For the post-dive mean values of endothelial MP, there was no significant difference between both the dives. The Oxygen breathing during decompression has a beneficial effect on bubble formation accelerating the washout of nitrogen loaded in tissues. Secondary oxygen-decompression stop could reduce bubble-induced platelet activation and the pro-coagulant activity of PMP release preventing the thrombotic event in the pathogenesis of decompression sickness.
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN AIR ANALYTICAL RESULTS
The Metals in Air data set contains analytical results for measurements of up to 11 metals in 344 air samples over 86 households. Samples were taken by pumping standardized air volumes through filters at indoor and outdoor sites around each household being sampled. The primary ...
Novel Method for Quantitative Estimation of Biofilms.
Syal, Kirtimaan
2017-10-01
Biofilm protects bacteria from stress and hostile environment. Crystal violet (CV) assay is the most popular method for biofilm determination adopted by different laboratories so far. However, biofilm layer formed at the liquid-air interphase known as pellicle is extremely sensitive to its washing and staining steps. Early phase biofilms are also prone to damage by the latter steps. In bacteria like mycobacteria, biofilm formation occurs largely at the liquid-air interphase which is susceptible to loss. In the proposed protocol, loss of such biofilm layer was prevented. In place of inverting and discarding the media which can lead to the loss of the aerobic biofilm layer in CV assay, media was removed from the formed biofilm with the help of a syringe and biofilm layer was allowed to dry. The staining and washing steps were avoided, and an organic solvent-tetrahydrofuran (THF) was deployed to dissolve the biofilm, and the absorbance was recorded at 595 nm. The protocol was tested for biofilm estimation of E. coli, B. subtilis and M. smegmatis, and compared with the traditional CV assays. Isoniazid drug molecule, a known inhibitor of M. smegmatis biofilm, was tested and its inhibitory effects were quantified by the proposed protocol. For ease in referring, this method has been described as the Syal method for biofilm quantification. This new method was found to be useful for the estimation of early phase biofilm and aerobic biofilm layer formed at the liquid-air interphase. The biofilms formed by all three tested bacteria-B. subtilis, E. coli and M. smegmatis, were precisely quantified.
The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...
An automated atmospheric sampling system operating on 747 airliners
NASA Technical Reports Server (NTRS)
Perkins, P.; Gustafsson, U. R. C.
1975-01-01
An air sampling system that automatically measures the temporal and spatial distribution of selected particulate and gaseous constituents of the atmosphere has been installed on a number of commercial airliners and is collecting data on commercial air routes covering the world. Measurements of constituents related to aircraft engine emissions and other pollutants are made in the upper troposphere and lower stratosphere (6 to 12 km) in support of the Global Air Sampling Program (GASP). Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This system includes specialized instrumentation for measuring carbon monoxide, ozone, water vapor, and particulates, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituents and related flight data are tape recorded in flight for later computer processing on the ground.
HIGH VOLUME INJECTION FOR GCMS ANALYSIS OF PARTICULATE ORGANIC SPECIES IN AMBIENT AIR
Detection of organic species in ambient particulate matter typically requires large air sample volumes, frequently achieved by grouping samples into monthly composites. Decreasing the volume of air sample required would allow shorter collection times and more convenient sample c...
A Protocol for Collecting Human Cardiac Tissue for Research.
Blair, Cheavar A; Haynes, Premi; Campbell, Stuart G; Chung, Charles; Mitov, Mihail I; Dennis, Donna; Bonnell, Mark R; Hoopes, Charles W; Guglin, Maya; Campbell, Kenneth S
2016-01-01
This manuscript describes a protocol at the University of Kentucky that allows a translational research team to collect human myocardium that can be used for biological research. We have gained a great deal of practical experience since we started this protocol in 2008, and we hope that other groups might be able to learn from our endeavors. To date, we have procured ~4000 samples from ~230 patients. The tissue that we collect comes from organ donors and from patients who are receiving a heart transplant or a ventricular assist device because they have heart failure. We begin our manuscript by describing the importance of human samples in cardiac research. Subsequently, we describe the process for obtaining consent from patients, the cost of running the protocol, and some of the issues and practical difficulties that we have encountered. We conclude with some suggestions for other researchers who may be considering starting a similar protocol.
A Protocol for Collecting Human Cardiac Tissue for Research
Blair, Cheavar A.; Haynes, Premi; Campbell, Stuart G.; Chung, Charles; Mitov, Mihail I.; Dennis, Donna; Bonnell, Mark R.; Hoopes, Charles W.; Guglin, Maya; Campbell, Kenneth S.
2016-01-01
This manuscript describes a protocol at the University of Kentucky that allows a translational research team to collect human myocardium that can be used for biological research. We have gained a great deal of practical experience since we started this protocol in 2008, and we hope that other groups might be able to learn from our endeavors. To date, we have procured ~4000 samples from ~230 patients. The tissue that we collect comes from organ donors and from patients who are receiving a heart transplant or a ventricular assist device because they have heart failure. We begin our manuscript by describing the importance of human samples in cardiac research. Subsequently, we describe the process for obtaining consent from patients, the cost of running the protocol, and some of the issues and practical difficulties that we have encountered. We conclude with some suggestions for other researchers who may be considering starting a similar protocol. PMID:28042604
A Mobile Satellite Experiment (MSAT-X) network definition
NASA Technical Reports Server (NTRS)
Wang, Charles C.; Yan, Tsun-Yee
1990-01-01
The network architecture development of the Mobile Satellite Experiment (MSAT-X) project for the past few years is described. The results and findings of the network research activities carried out under the MSAT-X project are summarized. A framework is presented upon which the Mobile Satellite Systems (MSSs) operator can design a commercial network. A sample network configuration and its capability are also included under the projected scenario. The Communication Interconnection aspect of the MSAT-X network is discussed. In the MSAT-X network structure two basic protocols are presented: the channel access protocol, and the link connection protocol. The error-control techniques used in the MSAT-X project and the packet structure are also discussed. A description of two testbeds developed for experimentally simulating the channel access protocol and link control protocol, respectively, is presented. A sample network configuration and some future network activities of the MSAT-X project are also presented.
Mars Sample Quarantine Protocol Workshop
NASA Technical Reports Server (NTRS)
DeVincenzi, Donald L. (Editor); Bagby, John (Editor); Race, Margaret (Editor); Rummel, John (Editor)
1999-01-01
The Mars Sample Quarantine Protocol (QP) Workshop was convened to deal with three specific aspects of the initial handling of a returned Mars sample: 1) biocontainment, to prevent uncontrolled release of sample material into the terrestrial environment; 2) life detection, to examine the sample for evidence of live organisms; and 3) biohazard testing, to determine if the sample poses any threat to terrestrial life forms and the Earth's biosphere. During the first part of the Workshop, several tutorials were presented on topics related to the workshop in order to give all participants a common basis in the technical areas necessary to achieve the objectives of the Workshop.
Adaptive Peer Sampling with Newscast
NASA Astrophysics Data System (ADS)
Tölgyesi, Norbert; Jelasity, Márk
The peer sampling service is a middleware service that provides random samples from a large decentralized network to support gossip-based applications such as multicast, data aggregation and overlay topology management. Lightweight gossip-based implementations of the peer sampling service have been shown to provide good quality random sampling while also being extremely robust to many failure scenarios, including node churn and catastrophic failure. We identify two problems with these approaches. The first problem is related to message drop failures: if a node experiences a higher-than-average message drop rate then the probability of sampling this node in the network will decrease. The second problem is that the application layer at different nodes might request random samples at very different rates which can result in very poor random sampling especially at nodes with high request rates. We propose solutions for both problems. We focus on Newscast, a robust implementation of the peer sampling service. Our solution is based on simple extensions of the protocol and an adaptive self-control mechanism for its parameters, namely—without involving failure detectors—nodes passively monitor local protocol events using them as feedback for a local control loop for self-tuning the protocol parameters. The proposed solution is evaluated by simulation experiments.
Duranty, Edward R; Roosendaal, Timothy J; Pitman, Stan G; Tucker, Joseph C; Owsley, Stanley L; Suter, Jonathan D; Alvine, Kyle James
2018-03-31
High pressure hydrogen gas is known to adversely affect metallic components of compressors, valves, hoses, and actuators. However, relatively little is known about the effects of high pressure hydrogen on the polymer sealing and barrier materials also found within these components. More study is required in order to determine the compatibility of common polymer materials found in the components of the hydrogen fuel delivery infrastructure with high pressure hydrogen. As a result, it is important to consider the changes in physical properties such as friction and wear in situ while the polymer is exposed to high pressure hydrogen. In this protocol, we present a method for testing the friction and wear properties of ethylene propylene diene monomer (EPDM) elastomer samples in a 28 MPa high pressure hydrogen environment using a custom-built in situ pin-on-flat linear reciprocating tribometer. Representative results from this testing are presented which indicate that the coefficient of friction between the EPDM sample coupon and steel counter surface is increased in high pressure hydrogen as compared to the coefficient of friction similarly measured in ambient air.
Carter Carburetor Weekly Air Monitoring & Sampling Report - March 7, 2013 - March 13, 2016
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Monitoring human exposure to urban air pollutants
Barale, R.; Barrai, I.; Sbrana, I.; Migliore, L.; Marrazzini, A.; Scarcelli, V.; Bacci, E.; Di Sibio, A.; Tessa, A.; Cocchi, L.; Lubrano, V.; Vassalle, C.; He, J.
1993-01-01
A multidisciplinary study on a general population exposed to vehicle exhaust was undertaken in Pisa in 1991. Environmental factors such as air pollution and those associated with lifestyle were studied. Meanwhile, biological and medical indicators of health condition were investigated. Chromosomal aberrations, sister chromatid exchanges (SCEs), and micronuclei in lymphocytes were included for the assessment of the genotoxic risk. Because of the large number (3800) of subjects being investigated, standardization of protocols was compulsory. The results on data reproducibility are reported. To assess the reliability of the protocol on a large scale, the population of Porto Tolle, a village located in northeast Italy, was studied and compared to a subset of the Pisa population. Preliminary results showed that probable differences between the two populations and invididuals were present in terms of SCE frequencies. The study was potentially able to detect the effects of several factors such as age, smoking, genetics, and environment. The in vitro treatment of lymphocytes with diepoxybutane confirmed the presence of more responsive individuals and permitted us to investigate the genetic predisposition to genetic damage. The possible influence of environmental factors was studied by correlation analyses with external exposure to air pollutants as well as with several lifestyle factors. PMID:8143653
Variations in incubator temperature and humidity management: a survey of current practice.
Deguines, C; Décima, P; Pelletier, A; Dégrugilliers, L; Ghyselen, L; Tourneux, P
2012-03-01
To describe and assess routine procedures and practices for incubator temperature and humidity management in France in 2009. A questionnaire was sent to all the 186 neonatal care units in France. The questionnaire return rate was 86%. Seventy-five per cent of the units preferred skin servo-control to air temperature control in routine practice. Air temperature control was mainly used for infants with a gestational age of more than 28 weeks and aged over 7 days of life. In general, thermal management decisions did not depend on the infant's age but were based on a protocol applied specifically by each unit. All units humidified the incubator air, but there was a large difference between the lowest and highest reported humidity values (45% and 100% assumed to be a maximal value, respectively). More than 65% of the units used a fixed humidity value, rather than a variable, protocol-derived value. We observed large variations in incubator temperature and humidity management approaches from one neonatal care unit to another. There is a need for more evidence to better inform practice. A task force should be formed to guide clinical practice. © 2011 The Author(s)/Acta Paediatrica © 2011 Foundation Acta Paediatrica.
Air sampling workshop: October 24-25, 1978
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-06-01
A two-day workshop was held in October 1978 on air sampling strategies for the occupational environment. Strategies comprise the elements of implementing an air sampling program including deciding on the extent of sampling, selecting appropriate types of measurement, placing sampling instruments properly, and interpreting sample results correctly. All of these elements are vital in the reliable assessment of occupational exposures yet their coverage in the industrial hygiene literature is meager. Although keyed to a few introductory topics, the agenda was sufficiently informal to accommodate extemporaneous discussion on any subject related to sampling strategies. Questions raised during the workshop mirror themore » status of air sampling strategy as much as the factual information that was presented. It may be concluded from the discussion and questions that air sampling strategy is an elementary state and urgently needs concerted attention from the industrial hygiene profession.« less
An automated atmospheric sampling system operating on 747 airliners
NASA Technical Reports Server (NTRS)
Perkins, P. J.; Gustafsson, U. R. C.
1976-01-01
An air sampling system that automatically measures the temporal and spatial distribution of particulate and gaseous constituents of the atmosphere is collecting data on commercial air routes covering the world. Measurements are made in the upper troposphere and lower stratosphere (6 to 12 km) of constituents related to aircraft engine emissions and other pollutants. Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This unique system includes specialized instrumentation, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituent and related flight data are tape recorded in flight for later computer processing on the ground.
An efficacious oral health care protocol for immunocompromised patients.
Solomon, C S; Shaikh, A B; Arendorf, T M
1995-01-01
A twice-weekly oral and perioral examination was provided to 120 patients receiving antineoplastic therapy. Sixty patients were monitored while following the traditional hospital oral care protocol (chlorhexidine, hydrogen peroxide, sodium bicarbonate, thymol glycol, benzocaine mouthrinse, and nystatin). The mouth care protocol was then changed (experimental protocol = chlorhexidine, benzocaine lozenges, amphotericin B lozenges), and patients were monitored until the sample size matched that of the hospital mouth care regime. There was a statistically significant reduction in oral complications upon introduction and maintenance of the experimental protocol.
PROTOCOL FOR EXAMINATION OF THE INNER CAN CLOSURE WELD REGION FOR 3013 DE CONTAINERS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mickalonis, J.
2014-09-16
The protocol for the examination of the inner can closure weld region (ICCWR) for 3013 DE containers is presented within this report. The protocol includes sectioning of the inner can lid section, documenting the surface condition, measuring corrosion parameters, and storing of samples. This protocol may change as the investigation develops since findings may necessitate additional steps be taken. Details of the previous analyses, which formed the basis for this protocol, are also presented.
On fixed-area plot sampling for downed coarse woody debris
Jeffrey H. Gove; Paul C. Van Deusen
2011-01-01
The use of fixed-area plots for sampling down coarse woody debris is reviewed. A set of clearly defined protocols for two previously described methods is established and a new method, which we call the 'sausage' method, is developed. All methods (protocols) are shown to be unbiased for volume estimation, but not necessarily for estimation of population...
The purpose of this protocol is to provide guidelines for the analysis of hair samples for total mercury by cold vapor atomic fluorescence (CVAFS) spectrometry. This protocol describes the methodology and all other analytical aspects involved in the analysis. Keywords: hair; s...
21 CFR 610.2 - Requests for samples and protocols; official release.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Biologics Evaluation and Research, a manufacturer shall not distribute a lot of a product until the lot is... Evaluation and Research, a manufacturer shall not distribute a lot of a biological product until the lot is... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Requests for samples and protocols; official...
21 CFR 610.2 - Requests for samples and protocols; official release.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Biologics Evaluation and Research, a manufacturer shall not distribute a lot of a product until the lot is... Evaluation and Research, a manufacturer shall not distribute a lot of a biological product until the lot is... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Requests for samples and protocols; official...
Justin D. Waskiewicz; Laura S. Kenefic; Nicole S. Rogers; Joshua J. Puhlick; John C. Brissette; Richard J. Dionne
2015-01-01
The U.S. Forest Service, Northern Research Station has been conducting research on the silviculture of northern conifers on the Penobscot Experimental Forest (PEF) in Maine since 1950. Formal study plans provide guidance and specifications for the experimental treatments, but documentation is also needed to ensure consistency in data collection and sampling protocols....
NASA Technical Reports Server (NTRS)
Fetzer, Eric J.; Lambrigtsen, Bjorn H.; Eldering, Annmarie; Aumann, Hartmut H.; Chahine, Moustafa T.
2006-01-01
We examine differences in total precipitable water vapor (PWV) from the Atmospheric Infrared Sounder (AIRS) and the Advanced Microwave Scanning Radiometer (AMSR-E) experiments sharing the Aqua spacecraft platform. Both systems provide estimates of PWV over water surfaces. We compare AIRS and AMSR-E PWV to constrain AIRS retrieval uncertainties as functions of AIRS retrieved infrared cloud fraction. PWV differences between the two instruments vary only weakly with infrared cloud fraction up to about 70%. Maps of AIRS-AMSR-E PWV differences vary with location and season. Observational biases, when both instruments observe identical scenes, are generally less than 5%. Exceptions are in cold air outbreaks where AIRS is biased moist by 10-20% or 10-60% (depending on retrieval processing) and at high latitudes in winter where AIRS is dry by 5-10%. Sampling biases, from different sampling characteristics of AIRS and AMSR-E, vary in sign and magnitude. AIRS sampling is dry by up to 30% in most high-latitude regions but moist by 5-15% in subtropical stratus cloud belts. Over the northwest Pacific, AIRS samples conditions more moist than AMSR-E by a much as 60%. We hypothesize that both wet and dry sampling biases are due to the effects of clouds on the AIRS retrieval methodology. The sign and magnitude of these biases depend upon the types of cloud present and on the relationship between clouds and PWV. These results for PWV imply that climatologies of height-resolved water vapor from AIRS must take into consideration local meteorological processes affecting AIRS sampling.
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2014 CFR
2014-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2012 CFR
2012-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2013 CFR
2013-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
Vismarra, Alice; Barilli, Elena; Miceli, Maura; Mangia, Carlo; Bacci, Cristina; Brindani, Franco; Kramer, Laura
2017-01-24
Toxoplasmosis is a zoonotic disease caused by the protozoan Toxoplasma gondii. Ingestion of raw milk has been suggested as a risk for transmission to humans. Here the authors evaluated pre-treatment protocols for DNA extraction on T. gondii tachyzoite-spiked sheep milk with the aim of identifying the method that resulted in the most rapid and reliable polymerase chain reaction (PCR) positivity. This protocol was then used to analyse milk samples from sheep of three different farms in Southern Italy, including real time PCR for DNA quantification and PCR-restriction fragment length polymorphism for genotyping. The pre-treatment protocol using ethylenediaminetetraacetic acid and Tris-HCl to remove casein gave the best results in the least amount of time compared to the others on spiked milk samples. One sample of 21 collected from sheep farms was positive on one-step PCR, real time PCR and resulted in a Type I genotype at one locus (SAG3). Milk usually contains a low number of tachyzoites and this could be a limiting factor for molecular identification. Our preliminary data has evaluated a rapid, cost-effective and sensitive protocol to treat milk before DNA extraction. The results of the present study also confirm the possibility of T. gondii transmission through consumption of raw milk and its unpasteurised derivatives.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air...
Carter Carburetor Weekly Air Monitoring & Sampling Report - November 30, 2015 – December 6, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - October 26, 2015 – November 1, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - February 15, 2016 – February 21, 2016
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - October 12, 2015 – October 18, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - November 23, 2015 – November 29, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - October 5, 2015 – October 11, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - February 1, 2016 – February 7, 2016
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - September 28, 2015 – October 4, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - November 16, 2015 – November 22, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - November 9, 2015 – November 15, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - October 19, 2015 – October 25, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Carter Carburetor Weekly Air Monitoring & Sampling Report - November 2, 2015 – November 8, 2015
Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati
Granato, G.E.; Smith, K.P.
1999-01-01
Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.
NASA Astrophysics Data System (ADS)
Cheng, Yuan; Duan, Feng-kui; He, Ke-bin; Du, Zhen-yu; Zheng, Mei; Ma, Yong-liang
2012-12-01
Three temperature protocols with different peak inert mode temperature (Tpeak-inert) were compared based on source and ambient samples (both untreated and extracted using a mixture of hexane, methylene chloride, and acetone) collected in Beijing, China. The ratio of EC580 (elemental carbon measured by the protocol with a Tpeak-inert of 580 °C; similar hereinafter) to EC850 could be as high as 4.8 for biomass smoke samples whereas the ratio was about 1.0 for diesel and gasoline exhaust samples. The EC580 to EC850 ratio averaged 1.95 ± 0.89 and 1.13 ± 0.20 for the untreated and extracted ambient samples, whereas the EC580 to EC650 ratio of ambient samples was 1.22 ± 0.10 and 1.20 ± 0.12 before and after extraction. It was suggested that there are two competing mechanisms for the effects of Tpeak-inert on the EC results such that when Tpeak-inert is increased, one mechanism tends to decrease EC by increasing the amount of charring whereas the other tends to increase EC through promoting more charring to evolve before native EC. Results from this study showed that EC does not always decrease when increasing the peak inert mode temperature. Moreover, reducing the charring amount could improve the protocols agreement on EC measurements, whereas temperature protocol would not influence the EC results if no charring is formed. This study also demonstrated the benefits of allowing for the OC and EC split occurring in the inert mode when a high Tpeak-inert is used (e.g., 850 °C).
Han, Yongming; Chen, Antony; Cao, Junji; Fung, Kochy; Ho, Fai; Yan, Beizhan; Zhan, Changlin; Liu, Suixin; Wei, Chong; An, Zhisheng
2013-01-01
Quantifying elemental carbon (EC) content in geological samples is challenging due to interferences of crustal, salt, and organic material. Thermal/optical analysis, combined with acid pretreatment, represents a feasible approach. However, the consistency of various thermal/optical analysis protocols for this type of samples has never been examined. In this study, urban street dust and soil samples from Baoji, China were pretreated with acids and analyzed with four thermal/optical protocols to investigate how analytical conditions and optical correction affect EC measurement. The EC values measured with reflectance correction (ECR) were found always higher and less sensitive to temperature program than the EC values measured with transmittance correction (ECT). A high-temperature method with extended heating times (STN120) showed the highest ECT/ECR ratio (0.86) while a low-temperature protocol (IMPROVE-550), with heating time adjusted for sample loading, showed the lowest (0.53). STN ECT was higher than IMPROVE ECT, in contrast to results from aerosol samples. A higher peak inert-mode temperature and extended heating times can elevate ECT/ECR ratios for pretreated geological samples by promoting pyrolyzed organic carbon (PyOC) removal over EC under trace levels of oxygen. Considering that PyOC within filter increases ECR while decreases ECT from the actual EC levels, simultaneous ECR and ECT measurements would constrain the range of EC loading and provide information on method performance. Further testing with standard reference materials of common environmental matrices supports the findings. Char and soot fractions of EC can be further separated using the IMPROVE protocol. The char/soot ratio was lower in street dusts (2.2 on average) than in soils (5.2 on average), most likely reflecting motor vehicle emissions. The soot concentrations agreed with EC from CTO-375, a pure thermal method.
An optimised protocol for molecular identification of Eimeria from chickens.
Kumar, Saroj; Garg, Rajat; Moftah, Abdalgader; Clark, Emily L; Macdonald, Sarah E; Chaudhry, Abdul S; Sparagano, Olivier; Banerjee, Partha S; Kundu, Krishnendu; Tomley, Fiona M; Blake, Damer P
2014-01-17
Molecular approaches supporting identification of Eimeria parasites infecting chickens have been available for more than 20 years, although they have largely failed to replace traditional measures such as microscopy and pathology. Limitations of microscopy-led diagnostics, including a requirement for specialist parasitological expertise and low sample throughput, are yet to be outweighed by the difficulties associated with accessing genomic DNA from environmental Eimeria samples. A key step towards the use of Eimeria species-specific PCR as a sensitive and reproducible discriminatory tool for use in the field is the production of a standardised protocol that includes sample collection and DNA template preparation, as well as primer selection from the numerous PCR assays now published. Such a protocol will facilitate development of valuable epidemiological datasets which may be easily compared between studies and laboratories. The outcome of an optimisation process undertaken in laboratories in India and the UK is described here, identifying four steps. First, samples were collected into a 2% (w/v) potassium dichromate solution. Second, oocysts were enriched by flotation in saturated saline. Third, genomic DNA was extracted using a QIAamp DNA Stool mini kit protocol including a mechanical homogenisation step. Finally, nested PCR was carried out using previously published primers targeting the internal transcribed spacer region 1 (ITS-1). Alternative methods tested included sample processing in the presence of faecal material, DNA extraction using a traditional phenol/chloroform protocol, the use of SCAR multiplex PCR (one tube and two tube versions) and speciation using the morphometric tool COCCIMORPH for the first time with field samples. Copyright © 2013 Dirk Vulpius The Authors. Published by Elsevier B.V. All rights reserved.
Smith, D.B.; Woodruff, L.G.; O'Leary, R. M.; Cannon, W.F.; Garrett, R.G.; Kilburn, J.E.; Goldhaber, M.B.
2009-01-01
In 2004, the US Geological Survey (USGS) and the Geological Survey of Canada sampled and chemically analyzed soils along two transects across Canada and the USA in preparation for a planned soil geochemical survey of North America. This effort was a pilot study to test and refine sampling protocols, analytical methods, quality control protocols, and field logistics for the continental survey. A total of 220 sample sites were selected at approximately 40-km intervals along the two transects. The ideal sampling protocol at each site called for a sample from a depth of 0-5 cm and a composite of each of the O, A, and C horizons. The <2-mm fraction of each sample was analyzed for Al, Ca, Fe, K, Mg, Na, S, Ti, Ag, As, Ba, Be, Bi, Cd, Ce, Co, Cr, Cs, Cu, Ga, In, La, Li, Mn, Mo, Nb, Ni, P, Pb, Rb, Sb, Sc, Sn, Sr, Te, Th, Tl, U, V, W, Y, and Zn by inductively coupled plasma-mass spectrometry and inductively coupled plasma-atomic emission spectrometry following a near-total digestion in a mixture of HCl, HNO3, HClO4, and HF. Separate methods were used for Hg, Se, total C, and carbonate-C on this same size fraction. Only Ag, In, and Te had a large percentage of concentrations below the detection limit. Quality control (QC) of the analyses was monitored at three levels: the laboratory performing the analysis, the USGS QC officer, and the principal investigator for the study. This level of review resulted in an average of one QC sample for every 20 field samples, which proved to be minimally adequate for such a large-scale survey. Additional QC samples should be added to monitor within-batch quality to the extent that no more than 10 samples are analyzed between a QC sample. Only Cr (77%), Y (82%), and Sb (80%) fell outside the acceptable limits of accuracy (% recovery between 85 and 115%) because of likely residence in mineral phases resistant to the acid digestion. A separate sample of 0-5-cm material was collected at each site for determination of organic compounds. A subset of 73 of these samples was analyzed for a suite of 19 organochlorine pesticides by gas chromatography. Only three of these samples had detectable pesticide concentrations. A separate sample of A-horizon soil was collected for microbial characterization by phospholipid fatty acid analysis (PLFA), soil enzyme assays, and determination of selected human and agricultural pathogens. Collection, preservation and analysis of samples for both organic compounds and microbial characterization add a great degree of complication to the sampling and preservation protocols and a significant increase to the cost for a continental-scale survey. Both these issues must be considered carefully prior to adopting these parameters as part of the soil geochemical survey of North America.
Onda, Yuichi; Kato, Hiroaki; Hoshi, Masaharu; Takahashi, Yoshio; Nguyen, Minh-Long
2015-01-01
The Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident resulted in extensive radioactive contamination of the environment via deposited radionuclides such as radiocesium and (131)I. Evaluating the extent and level of environmental contamination is critical to protecting citizens in affected areas and to planning decontamination efforts. However, a standardized soil sampling protocol is needed in such emergencies to facilitate the collection of large, tractable samples for measuring gamma-emitting radionuclides. In this study, we developed an emergency soil sampling protocol based on preliminary sampling from the FDNPP accident-affected area. We also present the results of a preliminary experiment aimed to evaluate the influence of various procedures (e.g., mixing, number of samples) on measured radioactivity. Results show that sample mixing strongly affects measured radioactivity in soil samples. Furthermore, for homogenization, shaking the plastic sample container at least 150 times or disaggregating soil by hand-rolling in a disposable plastic bag is required. Finally, we determined that five soil samples within a 3 m × 3-m area are the minimum number required for reducing measurement uncertainty in the emergency soil sampling protocol proposed here. Copyright © 2014 Elsevier Ltd. All rights reserved.
A Constrained and Versioned Data Model for TEAM Data
NASA Astrophysics Data System (ADS)
Andelman, S.; Baru, C.; Chandra, S.; Fegraus, E.; Lin, K.
2009-04-01
The objective of the Tropical Ecology Assessment and Monitoring Network (www.teamnetwork.org) is "To generate real time data for monitoring long-term trends in tropical biodiversity through a global network of TEAM sites (i.e. field stations in tropical forests), providing an early warning system on the status of biodiversity to effectively guide conservation action". To achieve this, the TEAM Network operates by collecting data via standardized protocols at TEAM Sites. The standardized TEAM protocols include the Climate, Vegetation and Terrestrial Vertebrate Protocols. Some sites also implement additional protocols. There are currently 7 TEAM Sites with plans to grow the network to 15 by June 30, 2009 and 50 TEAM Sites by the end of 2010. At each TEAM Site, data is gathered as defined by the protocols and according to a predefined sampling schedule. The TEAM data is organized and stored in a database based on the TEAM spatio-temporal data model. This data model is at the core of the TEAM Information System - it consumes and executes spatio-temporal queries, and analytical functions that are performed on TEAM data, and defines the object data types, relationships and operations that maintain database integrity. The TEAM data model contains object types including types for observation objects (e.g. bird, butterfly and trees), sampling unit, person, role, protocol, site and the relationship of these object types. Each observation data record is a set of attribute values of an observation object and is always associated with a sampling unit, an observation timestamp or time interval, a versioned protocol and data collectors. The operations on the TEAM data model can be classified as read operations, insert operations and update operations. Following are some typical operations: The operation get(site, protocol, [sampling unit block, sampling unit,] start time, end time) returns all data records using the specified protocol and collected at the specified site, block, sampling unit and time range. The operation insertSamplingUnit(sampling unit, site, protocol) saves a new sampling unit into the data model and links it with the site and protocol. The operation updateSampligUnit(sampling_unit_id, attribute, value) changes the attribute (e.g. latitude or longitude) of the sampling unit to the specified value. The operation insertData(observation record, site, protocol, sampling unit, timestamps, data collectors) saves a new observation record into the database and associates it with specified objects. The operation updateData(protocol, data_id, attribute, value) modifies the attribute of an existing observation record to the specified value. All the insert or update operations require: 1) authorization to ensure the user has necessary privileges to perform the operation; 2) timestamp validation to ensure the observation timestamps are in the designated time range specified in the sampling schedule; 3) data validation to check that the data records use correct taxonomy terms and data values. No authorization is performed for get operations, but under some specific condition, a username may be required for the purpose of authentication. Along with the validations above, the TEAM data model also supports human based data validation on observed data through the Data Review subsystem to ensure data quality. The data review is implemented by adding two attributes review_tag and review_comment to each observation data record. The attribute review_tag is used by a reviewer to specify the quality of data, and the attribute review_comment is for reviewers to give more information when a problem is identified. The review_tag attribute can be populated by either the system conducting QA/QC tests or by pre-specified scientific experts. The following is the review operation, which is actually a special case of the operation updateData: The operation updateReview(protocol, data_id, judgment, comment) sets the attribute review_tag and review_comment to the specified values. By systematically tracking every step, The TEAM data model can roll back to any previous state. This is achieved by introducing a historical data container for each editable object type. When the operation updateData is applied to an object to modify its attribute, the object will be tagged with the current timestamp and the name of the user who conducts the operation, the tagged object will then be moved into the historical data container, and finally a new object will be created with the new value for the specified attribute. The diagram illustrates the architecture of the TEAM data management system. A data collector can use the Data Ingestion subsystem to load new data records into the TEAM data model. The system establishes a first level of review (i.e. meets minimum data standards via QA/QC tests). Further review is done via experts and they can verify and provide their comments on data records through the Data Review subsystem. The data editor can then address data records based on the reviewer's comments. Users can use the Data Query and Download application to find data by sites, protocols and time ranges. The Data Query and Download system packages selected data with the data license and important metadata information into a single package and delivers it to the user.
Flow cytometry for enrichment and titration in massively parallel DNA sequencing
Sandberg, Julia; Ståhl, Patrik L.; Ahmadian, Afshin; Bjursell, Magnus K.; Lundeberg, Joakim
2009-01-01
Massively parallel DNA sequencing is revolutionizing genomics research throughout the life sciences. However, the reagent costs and labor requirements in current sequencing protocols are still substantial, although improvements are continuously being made. Here, we demonstrate an effective alternative to existing sample titration protocols for the Roche/454 system using Fluorescence Activated Cell Sorting (FACS) technology to determine the optimal DNA-to-bead ratio prior to large-scale sequencing. Our method, which eliminates the need for the costly pilot sequencing of samples during titration is capable of rapidly providing accurate DNA-to-bead ratios that are not biased by the quantification and sedimentation steps included in current protocols. Moreover, we demonstrate that FACS sorting can be readily used to highly enrich fractions of beads carrying template DNA, with near total elimination of empty beads and no downstream sacrifice of DNA sequencing quality. Automated enrichment by FACS is a simple approach to obtain pure samples for bead-based sequencing systems, and offers an efficient, low-cost alternative to current enrichment protocols. PMID:19304748
Jablonski, Rita A; Winstead, Vicki; Azuero, Andres; Ptacek, Travis; Jones-Townsend, Corteza; Byrd, Elizabeth; Geisinger, Maria L; Morrow, Casey
2017-09-01
Individuals with dysphagia who reside in nursing homes often receive inadequate mouth care and experience poor oral health. From a policy perspective, the combination of absent evidence-based mouth care protocols coupled with insufficient dental coverage create a pool of individuals at great risk for preventable infectious illnesses that contribute to high health care costs. The purpose of the current study was to determine (a) the safety of a mouth care protocol tailored for individuals with dysphagia residing in nursing homes without access to suction equipment, and (b) the feasibility of collecting oral and fecal samples for microbiota analyses. The mouth care protocol resulted in improved oral hygiene without aspiration, and oral and fecal samples were safely collected from participants. Policies supporting ongoing testing of evidence-based mouth care protocols for individuals with dysphagia are important to improve quality, demonstrate efficacy, and save health care costs. [Journal of Gerontological Nursing, 43(9), 9-15.]. Copyright 2017, SLACK Incorporated.
30 CFR 90.205 - Approved sampling devices; operation; air flowrate.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...
METHOD FOR MICRORNA ISOLATION FROM CLINICAL SERUM SAMPLES
Li, Yu; Kowdley, Kris V.
2012-01-01
MicroRNAs are a group of intracellular non-coding RNA molecules that have been implicated in a variety of human diseases. Due to their high stability in blood, microRNAs released into circulation could be potentially utilized as non-invasive biomarkers for diagnosis or prognosis. Current microRNA isolation protocols are specifically designed for solid tissues and are impractical for biomarker development utilizing small-volume serum samples on a large scale. Thus, a protocol for microRNA isolation from serum is needed to accommodate these conditions in biomarker development. To establish such a protocol, we developed a simplified approach to normalize sample input by using single synthetic spike-in microRNA. We evaluated three commonly used commercial microRNA isolation kits for the best performance by comparing RNA quality and yield. The manufacturer’s protocol was further modified to improve the microRNA yield from 200 μL of human serum. MicroRNAs isolated from a large set of clinical serum samples were tested on the miRCURY LNA real-time PCR panel and confirmed to be suitable for high-throughput microRNA profiling. In conclusion, we have established a proven method for microRNA isolation from clinical serum samples suitable for microRNA biomarker development. PMID:22982505
NASA Astrophysics Data System (ADS)
Kawakami, Shun; Sasaki, Toshihiko; Koashi, Masato
2017-07-01
An essential step in quantum key distribution is the estimation of parameters related to the leaked amount of information, which is usually done by sampling of the communication data. When the data size is finite, the final key rate depends on how the estimation process handles statistical fluctuations. Many of the present security analyses are based on the method with simple random sampling, where hypergeometric distribution or its known bounds are used for the estimation. Here we propose a concise method based on Bernoulli sampling, which is related to binomial distribution. Our method is suitable for the Bennett-Brassard 1984 (BB84) protocol with weak coherent pulses [C. H. Bennett and G. Brassard, Proceedings of the IEEE Conference on Computers, Systems and Signal Processing (IEEE, New York, 1984), Vol. 175], reducing the number of estimated parameters to achieve a higher key generation rate compared to the method with simple random sampling. We also apply the method to prove the security of the differential-quadrature-phase-shift (DQPS) protocol in the finite-key regime. The result indicates that the advantage of the DQPS protocol over the phase-encoding BB84 protocol in terms of the key rate, which was previously confirmed in the asymptotic regime, persists in the finite-key regime.
Analysis of EPA and DOE WIPP Air Sampling Data
During the April 2014 EPA visit to WIPP, EPA co-located four ambient air samplers with existing Department of Energy (DOE) ambient air samplers to independently corroborate DOE's reported air sampling results.
Creamer, E; Shore, A C; Deasy, E C; Galvin, S; Dolan, A; Walley, N; McHugh, S; Fitzgerald-Hughes, D; Sullivan, D J; Cunney, R; Coleman, D C; Humphreys, H
2014-03-01
Meticillin-resistant Staphylococcus aureus (MRSA) can be recovered from hospital air and from environmental surfaces. This poses a potential risk of transmission to patients. To investigate associations between MRSA isolates recovered from air and environmental surfaces with those from patients when undertaking extensive patient and environmental sampling. This was a prospective observational study of patients and their environment in eight wards of a 700-bed tertiary care hospital during 2010 and 2011. Sampling of patients, air and surfaces was carried out on all ward bays, with more extended environmental sampling in ward high-dependency bays and at particular times of the day. The genetic relatedness of isolates was determined by DNA microarray profiling and spa typing. MRSA was recovered from 30/706 (4.3%) patients and from 19/132 (14.4%) air samples. On 9/132 (6.8%) occasions both patient and air samples yielded MRSA. In 32 high-dependency bays, MRSA was recovered from 12/161 (7.4%) patients, 8/32 (25%) air samples, and 21/644 (3.3%) environmental surface samples. On 10/132 (7.6%) occasions, MRSA was isolated from air in the absence of MRSA-positive patients. Patient demographic data combined with spa typing and DNA microarray profiling revealed four likely transmission clusters, where patient and environmental isolates were deemed to be very closely related. Air sampling yielded MRSA on frequent occasions, especially in high-dependency bays. Environmental and air sampling combined with patient demographic data, spa typing and DNA microarray profiling indicated the presence of clusters that were not otherwise apparent. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Wong, C M; Vichit-Vadakan, N; Vajanapoom, N; Ostro, B; Thach, T Q; Chau, P Y K; Chan, E K P; Chung, R Y N; Ou, C Q; Yang, L; Peiris, J S M; Thomas, G N; Lam, T H; Wong, T W; Hedley, A J; Kan, H; Chen, B; Zhao, N; London, S J; Song, G; Chen, G; Zhang, Y; Jiang, L; Qian, Z; He, Q; Lin, H M; Kong, L; Zhou, D; Liang, S; Zhu, Z; Liao, D; Liu, W; Bentley, C M; Dan, J; Wang, B; Yang, N; Xu, S; Gong, J; Wei, H; Sun, H; Qin, Z
2010-11-01
In recent years, Asia has experienced rapid economic growth and a deteriorating environment caused by the increasing use of fossil fuels. Although the deleterious effects of air pollution from fossil-fuel combustion have been demonstrated in many Western nations, few comparable studies have been conducted in Asia. Time-series studies of daily mortality in Asian cities can contribute important new information to the existing body of knowledge about air pollution and health. Not only can these studies verify important health effects of air pollution in local regions in Asia, they can also help determine the relevance of existing air pollution studies to mortality and morbidity for policymaking and environmental controls. In addition, the studies can help identify factors that might modify associations between air pollution and health effects in various populations and environmental conditions. Collaborative multicity studies in Asia-especially when designed, conducted, and analyzed using a common protocol-will provide more robust air pollution effect estimates for the region as well as relevant, supportable estimates of local adverse health effects needed by environmental and public-health policymakers. The Public Health and Air Pollution in Asia (PAPA*) project, sponsored by the Health Effects Institute, consisted of four studies designed to assess the effects of air pollution on mortality in four large Asian cities, namely Bangkok, in Thailand, and Hong Kong, Shanghai, and Wuhan, in China. In the PAPA project, a Common Protocol was developed based on methods developed and tested in NMMAPS, APHEA, and time-series studies in the literature to help ensure that the four studies could be compared with each other and with previous studies by following an established protocol. The Common Protocol (found at the end of this volume) is a set of prescriptive instructions developed for the studies and used by the investigators in each city. It is flexible enough to allow for adjustments in methods to optimize the fit of health-effects models to each city's data set. It provides the basis for generating reproducible results in each city and for meta-estimates from combined data. By establishing a common methodology, factors that might influence the differences in results from previous studies can more easily be explored. Administrative support was provided to ensure that the highest quality data were used in the analysis. It is anticipated that the PAPA results will contribute to the international scientific discussion of how to conduct and interpret time-series studies of air pollution and will stimulate the development of high-quality routine systems for recording daily deaths and hospital admissions for time-series analysis. Mortality data were retrieved from routine databases with underlying causes of death coded using the World Health Organization (WHO) International Classification of Diseases, 9th revision or 10th revision (ICD-9, ICD-10). Air quality measurements included nitrogen dioxide (NO2), sulfur dioxide (SO2), particulate matter with aerodynamic diameter < or = 10 microm (PM10), and ozone (O3) and were obtained from several fixed-site air monitoring stations that were located throughout the metropolitan areas of the four cities and that met the standards of procedures for quality assurance and quality control carried out by local government units in each city. Using the Common Protocol, an optimized core model was established for each city to assess the effects of each of the four air pollutants on daily mortality using generalized linear modeling with adjustments for time trend, seasonality, and other time-varying covariates by means of a natural-spline smoothing function. The models were adjusted to suit local situations by correcting for influenza activity, autocorrelation, and special weather conditions. Researchers in Hong Kong, for example, used influenza activity based on frequency of respiratory mortality; researchers in Hong Kong and Shanghai used autoregressive terms for daily outcomes at lag days; and researchers in Wuhan used additional smoothing for periods with extreme weather conditions. For mortality due to all natural (nonaccidental) causes at all ages, the effects of air pollutants per 10-microg/m3 increase in concentration was found to be higher in Bangkok than in the three Chinese cities, with the exception of the effect of NO2 in Wuhan. The magnitude of the effects for cardiovascular and respiratory mortality were generally higher than for all natural mortality at all ages. In addition, the effects associated with PM10 and O3 in all natural, cardiovascular; and respiratory mortality were found to be higher in Bangkok than in the three Chinese cities. The explanation for these three findings might be related to consistently higher daily mean temperatures in Bangkok, variations in average time spent outdoors by the susceptible populations, and the fact that less air conditioning is available and used in Bangkok than in the other cities. However, when pollutant concentrations were incorporated into the excess risk estimates through the use of interquartile range (IQR), the excess risk was more comparable across the four cities. We found that the increases in effects among older age groups were greater in Bangkok than in the other three cities. After excluding data on extremely high concentrations of PM10 in Bangkok, the effect estimate associated with PM10 concentrations decreased in Bangkok (suggesting a convex relationship between risk and PM10, where risk levels off at high concentrations) instead of increasing, as it did in the other cities. This leveling off of effect estimates at high concentrations might be related to differences in vulnerability and exposure of the population to air pollution as well as to the sources of the air pollutant. IMPLICATIONS OF THE STUDY: The PAPA project is the first coordinated Asian multicity air pollution study ever published; this signifies the beginning of an era of cooperation and collaboration in Asia, with the development of a common protocol for coordination, data management, and analysis. The results of the study demonstrated that air pollution in Asia is a significant public health burden, especially given the high concentrations of pollutants and high-density populations in major cities. When compared with the effect estimates reported in the research literature of North America and Western Europe, the study's effect estimates for PM10 were generally similar and the effect estimates for gaseous pollutants were relatively higher. In Bangkok, however, a tropical city where total exposures to outdoor pollution might be higher than in most other cities, the observed effects were greater than those reported in the previous (i.e., Western) studies. In general, the results suggested that, even though social and environmental conditions across Asia might vary, it is still generally appropriate to apply to Asia the effect estimates for other health outcomes from previous studies in the West. The results also strongly support the adoption of the global air quality guidelines recently announced by WHO.
Low-cost cryo-light microscopy stage fabrication for correlated light/electron microscopy.
Carlson, David B; Evans, James E
2011-06-05
The coupling of cryo-light microscopy (cryo-LM) and cryo-electron microscopy (cryo-EM) poses a number of advantages for understanding cellular dynamics and ultrastructure. First, cells can be imaged in a near native environment for both techniques. Second, due to the vitrification process, samples are preserved by rapid physical immobilization rather than slow chemical fixation. Third, imaging the same sample with both cryo-LM and cryo-EM provides correlation of data from a single cell, rather than a comparison of "representative samples". While these benefits are well known from prior studies, the widespread use of correlative cryo-LM and cryo-EM remains limited due to the expense and complexity of buying or building a suitable cryogenic light microscopy stage. Here we demonstrate the assembly, and use of an inexpensive cryogenic stage that can be fabricated in any lab for less than $40 with parts found at local hardware and grocery stores. This cryo-LM stage is designed for use with reflected light microscopes that are fitted with long working distance air objectives. For correlative cryo-LM and cryo-EM studies, we adapt the use of carbon coated standard 3-mm cryo-EM grids as specimen supports. After adsorbing the sample to the grid, previously established protocols for vitrifying the sample and transferring/handling the grid are followed to permit multi-technique imaging. As a result, this setup allows any laboratory with a reflected light microscope to have access to direct correlative imaging of frozen hydrated samples.
IMPROVED TEST METHODS FOR ELECTRONIC AIR CLEANERS
The objective of this project was to develop a fractional filtration efficiency test protocol for residential electrostatic precipitators (ESPs) that avoids the limitations of the ASHRAE 52.2 method. Specifically, the objectives were to a) determine the change in efficiency that ...
Aloisio, Michelangelo; Bortot, Barbara; Gandin, Ilaria; Severini, Giovanni Maria; Athanasakis, Emmanouil
2017-02-01
Chimerism status evaluation of post-allogeneic hematopoietic stem cell transplantation samples is essential to predict post-transplant relapse. The most commonly used technique capable of detecting small increments of chimerism is quantitative real-time PCR. Although this method is already used in several laboratories, previously described protocols often lack sensitivity and the amount of the DNA required for each chimerism analysis is too high. In the present study, we compared a novel semi-nested allele-specific real-time PCR (sNAS-qPCR) protocol with our in-house standard allele-specific real-time PCR (gAS-qPCR) protocol. We selected two genetic markers and analyzed technical parameters (slope, y-intercept, R2, and standard deviation) useful to determine the performances of the two protocols. The sNAS-qPCR protocol showed better sensitivity and precision. Moreover, the sNAS-qPCR protocol requires, as input, only 10 ng of DNA, which is at least 10-fold less than the gAS-qPCR protocols described in the literature. Finally, the proposed sNAS-qPCR protocol could prove very useful for performing chimerism analysis with a small amount of DNA, as in the case of blood cell subsets.
NASA Astrophysics Data System (ADS)
Kim, Youngseob; Sartelet, Karine; Seigneur, Christian; Charron, Aurélie; Besombes, Jean-Luc; Jaffrezo, Jean-Luc; Marchand, Nicolas; Polo, Lucie
2016-09-01
Exhaust emissions of semi-volatile organic compounds (SVOC) from passenger vehicles are usually estimated only for the particle phase via the total particulate matter measurements. However, they also need to be estimated for the gas phase, as they are semi-volatile. To better estimate SVOC emission factors of passenger vehicles, a measurement campaign using a chassis dynamometer was conducted with different instruments: (1) a constant volume sampling (CVS) system in which emissions were diluted with filtered air and sampling was performed on filters and polyurethane foams (PUF) and (2) a Dekati Fine Particle Sampler (FPS) in which emissions were diluted with purified air and sampled with on-line instruments (PTR-ToF-MS, HR-ToF-AMS, MAAP, CPC). Significant differences in the concentrations of organic carbon (OC) measured by the instruments are observed. The differences can be explained by sampling artefacts, differences between (1) the time elapsed during sampling (in the case of filter and PUF sampling) and (2) the time elapsed from emission to measurement (in the case of on-line instruments), which vary from a few seconds to 15 min, and by the different dilution factors. To relate elapsed times and measured concentrations of OC, the condensation of SVOC between the gas and particle phases is simulated with a dynamic aerosol model. The simulation results allow us to understand the relation between elapsed times and concentrations in the gas and particle phases. They indicate that the characteristic times to reach thermodynamic equilibrium between gas and particle phases may be as long as 8 min. Therefore, if the elapsed time is less than this characteristic time to reach equilibrium, gas-phase SVOC are not at equilibrium with the particle phase and a larger fraction of emitted SVOC will be in the gas phase than estimated by equilibrium theory, leading to an underestimation of emitted OC if only the particle phase is considered or if the gas-phase SVOC are estimated by equilibrium theory. Current European emission inventories for passenger cars do not yet estimate gas-phase SVOC emissions, although they may represent 60% of total emitted SVOC (gas + particle phases).
Elliott, Paul; Peakman, Tim C
2008-04-01
UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is completed on whole blood from all participants, since such assays need to be conducted on fresh samples (whereas other assays can be done on stored samples). By the end of the recruitment phase, 15 million sample aliquots will be stored in two geographically separate archives: 9.5 million in a -80 degrees C automated archive and 5.5 million in a manual liquid nitrogen archive at -180 degrees C. Because of the size of the study and the numbers of samples obtained from participants, the protocol stipulates a highly automated approach for the processing and storage of samples. Implementation of the processes, technology, systems and facilities has followed best practices used in manufacturing industry to reduce project risk and to build in quality and robustness. The data produced from sample collection, processing and storage are highly complex and are managed by a commercially available LIMS system fully integrated with the entire process. The sample handling and storage protocol adopted by UK Biobank provides quality assured and validated methods that are feasible within the available funding and reflect the size and aims of the project. Experience from recruiting and processing the first 40,000 participants to the study demonstrates that the adopted methods and technologies are fit-for-purpose and robust.
Palmans, Hugo; Nafaa, Laila; De, Jans Jo; Gillis, Sofie; Hoornaert, Marie-Thérèse; Martens, Chantal; Piessens, Marleen; Thierens, Hubert; Van der Plaetsen, Ann; Vynckier, Stefaan
2002-02-07
In recent years, a change has been proposed from air kerma based reference dosimetry to absorbed dose based reference dosimetry for all radiotherapy beams of ionizing radiation. In this paper, a dosimetry study is presented in which absorbed dose based dosimetry using recently developed formalisms was compared with air kerma based dosimetry using older formalisms. Three ionization chambers of each of three different types were calibrated in terms of absorbed dose to water and air kerma and sent to five hospitals. There, reference dosimetry with all the chambers was performed in a total of eight high-energy clinical photon beams. The selected chamber types were the NE2571, the PTW-30004 and the Wellhöfer-FC65G (previously Wellhöfer-IC70). Having a graphite wall, they exhibit a stable volume and the presence of an aluminium electrode ensures the robustness of these chambers. The data were analysed with the most important recommendations for clinical dosimetry: IAEA TRS-398, AAPM TG-51, IAEA TRS-277, NCS report-2 (presently recommended in Belgium) and AAPM TG-21. The necessary conversion factors were taken from those protocols, or calculated using the data in the different protocols if data for a chamber type are lacking. Polarity corrections were within 0.1% for all chambers in all beams. Recombination corrections were consistent with theoretical predictions, did not vary within a chamber type and only slightly between different chamber types. The maximum chamber-to-chamber variations of the dose obtained with the different formalisms within the same chamber type were between 0.2% and 0.6% for the NE2571, between 0.2% and 0.6% for the PTW-30004 and 0.1% and 0.3% for the Wellhöfer-FC65G for the different beams. The absorbed dose results for the NE2571 and Wellhöfer-FC65G chambers were in good agreement for all beams and all formalisms. The PTW-30004 chambers gave a small but systematically higher result compared to the result for the NE2571 chambers (on the average 0.1% for IAEA TRS-277, 0.3% for NCS report-2 and AAPM TG-21 and 0.4% for IAEA TRS-398 and AAPM TG-51). Within the air kerma based protocols, the results obtained with the TG-21 protocol were 0.4-0.8% higher mainly due to the differences in the data used. Both absorbed dose to water based formalisms resulted in consistent values within 0.3%. The change from old to new formalisms is discussed together with the traceability of calibration factors obtained at the primary absorbed dose and air kerma standards in the reference beams (60Co). For the particular situation in Belgium (calibrations at the Laboratory for Standard Dosimetry of Ghent) the change amounts to 0.1-0.6%. This is similar to the magnitude of the change determined in other countries.
A quarantine protocol for analysis of returned extraterrestrial samples
NASA Technical Reports Server (NTRS)
Bagby, J. R.; Sweet, H. C.; Devincenzi, D. L.
1983-01-01
A protocol is presented for the analysis at an earth-orbiting quarantine facility of return samples of extraterrestrial material that might contain (nonterrestrial) life forms. The protocol consists of a series of tests designed to determine whether the sample, conceptualized as a 1-kg sample of Martian soil, is free from nonterrestrial biologically active agents and so may safely be sent to a terrestrial containment facility, or it exhibits biological activity requiring further (second-order) testing outside the biosphere. The first-order testing procedure seeks to detect the presence of any replicating organisms or toxic substances through a series of experiments including gas sampling, analysis of radioactivity, stereomicroscopic inspection, chemical analysis, microscopic examination, the search for metabolic products under growth conditions, microbiologicl assays, and the challenge of cultured cells with any agents found or with the extraterrestrial material as is. Detailed plans for the second-order testing would be developed in response to the actual data received from primary testing.
A Field-Based Cleaning Protocol for Sampling Devices Used in Life-Detection Studies
NASA Astrophysics Data System (ADS)
Eigenbrode, Jennifer; Benning, Liane G.; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E. F.
2009-06-01
Analytical approaches to extant and extinct life detection involve molecular detection often at trace levels. Thus, removal of biological materials and other organic molecules from the surfaces of devices used for sampling is essential for ascertaining meaningful results. Organic decontamination to levels consistent with null values on life-detection instruments is particularly challenging at remote field locations where Mars analog field investigations are carried out. Here, we present a seven-step, multi-reagent decontamination method that can be applied to sampling devices while in the field. In situ lipopolysaccharide detection via low-level endotoxin assays and molecular detection via gas chromatography-mass spectrometry were used to test the effectiveness of the decontamination protocol for sampling of glacial ice with a coring device and for sampling of sediments with a rover scoop during deployment at Arctic Mars-analog sites in Svalbard, Norway. Our results indicate that the protocols and detection technique sufficiently remove and detect low levels of molecular constituents necessary for life-detection tests.
A field-based cleaning protocol for sampling devices used in life-detection studies.
Eigenbrode, Jennifer; Benning, Liane G; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E F
2009-06-01
Analytical approaches to extant and extinct life detection involve molecular detection often at trace levels. Thus, removal of biological materials and other organic molecules from the surfaces of devices used for sampling is essential for ascertaining meaningful results. Organic decontamination to levels consistent with null values on life-detection instruments is particularly challenging at remote field locations where Mars analog field investigations are carried out. Here, we present a seven-step, multi-reagent decontamination method that can be applied to sampling devices while in the field. In situ lipopolysaccharide detection via low-level endotoxin assays and molecular detection via gas chromatography-mass spectrometry were used to test the effectiveness of the decontamination protocol for sampling of glacial ice with a coring device and for sampling of sediments with a rover scoop during deployment at Arctic Mars-analog sites in Svalbard, Norway. Our results indicate that the protocols and detection technique sufficiently remove and detect low levels of molecular constituents necessary for life-detection tests.
Frazier, Melanie; Miller, A. Whitman; Lee, Henry; Reusser, Deborah A.
2013-01-01
Discharge from the ballast tanks of ships is one of the primary vectors of nonindigenous species in marine environments. To mitigate this environmental and economic threat, international, national, and state entities are establishing regulations to limit the concentration of living organisms that may be discharged from the ballast tanks of ships. The proposed discharge standards have ranged from zero detectable organisms to 3. If standard sampling methods are used, verifying whether ballast discharge complies with these stringent standards will be challenging due to the inherent stochasticity of sampling. Furthermore, at low concentrations, very large volumes of water must be sampled to find enough organisms to accurately estimate concentration. Despite these challenges, adequate sampling protocols comprise a critical aspect of establishing standards because they help define the actual risk level associated with a standard. A standard that appears very stringent may be effectively lax if it is paired with an inadequate sampling protocol. We describe some of the statistical issues associated with sampling at low concentrations to help regulators understand the uncertainties of sampling as well as to inform the development of sampling protocols that ensure discharge standards are adequately implemented.
Luksamijarulkul, Pipat; Sundhiyodhin, Viboonsri; Luksamijarulkul, Soavalug; Kaewboonchoo, Orawan
2004-06-01
The air quality in mass transport buses, especially air-conditioned buses may affect bus drivers who work full time. Bus numbers 16, 63, 67 and 166 of the Seventh Bus Zone of Bangkok Mass Transit Authority were randomly selected to investigate for microbial air quality. Nine air-conditioned buses and 2-4 open-air buses for each number of the bus (36 air-conditioned buses and 12 open-air buses) were included. Five points of in-bus air samples in each studied bus were collected by using the Millipore A ir Tester Totally, 180 and 60 air samples collected from air-conditioned buses and open-air buses were cultured for bacterial and fungal counts. The bus drivers who drove the studied buses were interviewed towards histories of work-related illness while working. The results revealed that the mean +/- SD of bacterial counts in the studied open-air buses ranged from 358.50 +/- 146.66 CFU/m3 to 506 +/- 137.62 CFU/m3; bus number 16 had the highest level. As well as the mean +/- SD of fungal counts which ranged from 93.33 +/- 44.83 CFU/m3 to 302 +/- 294.65 CFU/m3; bus number 166 had the highest level. Whereas, the mean +/- SD of bacterial counts in the studied air-conditioned buses ranged from 115.24 +/- 136.01 CFU/m3 to 244.69 +/- 234.85 CFU/m3; bus numbers 16 and 67 had the highest level. As well as the mean +/- SD of fungal counts which rangedfrom 18.84 +/- 39.42 CFU/m3 to 96.13 +/- 234.76 CFU/m3; bus number 166 had the highest level. When 180 and 60 studied air samples were analyzed in detail, it was found that 33.33% of the air samples from open-air buses and 6.11% of air samples from air-conditioned buses had a high level of bacterial counts (> 500 CFU/m3) while 6.67% of air samples from open-air buses and 2.78% of air samples from air-conditioned buses had a high level of fungal counts (> 500 CFU/m3). Data from the history of work-related illnesses among the studied bus drivers showed that 91.67% of open-air bus drivers and 57.28% of air-conditioned bus drivers had symptoms of work-related illnesses, p = 0.0185.
Rousová, Jana; Chintapalli, Manikyala R; Lindahl, Anastasia; Casey, Jana; Kubátová, Alena
2018-04-06
Carboxylic acids and aldehydes are present in ambient air particulate matter (PM) originating from both primary emission and secondary production in air and may, due to their polarity have, an impact on formation of cloud condensation nuclei. Their simultaneous determination may provide improved understanding of atmospheric processes. We developed a new analytical method allowing for a single step determination of majority of carboxylic acids and aldehydes (+95 compounds). This sample preparation employed O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA·HCl) in methanol to yield oximes (for aldehydes) and methyl esters (for majority of acids); with the limits of detection of 0.02-1 ng per injection, corresponding to approximately 0.4-20 μg/g PM . Subsequent trimethylsilylation with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) was employed only for aromatic acids, which were not completely esterified, and for hydroxyl groups. Our method, in contrast to previous primarily qualitative studies, based on derivatization with an aqueous PFBHA followed by BSTFA derivatization, is less labor-intesive and reduces sample losses caused by an evaporation. The method was tested with a broad range of functionalized compounds (95), including monocarboxylic, dicarboxylic and aromatic acids, ketoacids, hydroxyacids and aldehydes. The developed protocol was applied to wood smoke (WS) and urban air standard reference material 1648b (UA) PM. The observed concentrations of aldehydes were 10-3000 μg/g PM in WS PM and 10-900 μg/g PM in UA PM, while those of acids were 20-1800 μg/g PM in WS PM and 15-1200 μg/g PM in UA PM. The most prominent aldehydes were syringaldehyde and vanillin in WS PM and glyoxal in UA PM. The most abundant acids in both PM samples were short-chain dicarboxylic acids (≤C 10 ). WS PM had a high abundance of hydroxyacids (vanillic and malic acids) as well as ketoacids (glutaric and oxalacetic) while UA PM also featured a high abundance of long-chain monocarboxylic acids (≥C 16 ). Copyright © 2018 Elsevier B.V. All rights reserved.
Applications of Functional Analytic and Martingale Methods to Problems in Queueing Network Theory.
1983-05-14
8217’") Air Force Office of Scientific Research Sf. ADDRESS (Cllty. State and ZIP Code) 7b. ADDRESS (City. State and ZIP Code) Directorate of Mathematical... Scientific Report on Air Force Grant #82-0167 Principal Investigator: Professor Walter A. Rosenkrantz I. Publications (1) Calculation of the LaPlace transform...whether or not a protocol for accessing a comunications channel is stable. In AFOSR 82-0167, Report No. 3 we showed that the SLOTTED ALOHA Multi access
Evaluating the risk of decompression sickness for a yo-yo dive using a rat model.
Ofir, Dror; Yanir, Yoav; Abramovich, Amir; Bar, Ronen; Arieli, Yehuda
2016-01-01
The frequent ascents made during yo-yo diving may contribute to gas bubble clearance but paradoxically may also increase the risk of central nervous system decompression illness (DCI). We evaluated the risk of DCI due to yo-yo dives with very short surface intervals, using a controlled animal model. Dives were conducted on air to a depth of 90 meters (10 atmospheres absolute) for 32 minutes of bottom time, at a descent/ascent rate of 10 meters/ minute. Sprague-Dawley rats weighing ~ 300 grams were divided randomly into three groups. Group A performed a square dive protocol without any surface intervals, Group B conducted a protocol that included two surface intervals during the dive, and Group C performed a protocol with three surface intervals. Ascent/descent rate for surface intervals, each lasting one minute, was also 10 meters/minute. Manifestations of DCI were observed in 13 of 16 animals in Group A (81.3%), six of 12 in Group B (58.3%), and two of 12 in Group C (16.7%). Mortality rates were similar in all groups. Surface intervals during dives breathing air significantly reduced DCI risk in the rat. Further studies are required using a larger animal model to reinforce the results of the present investigation.
An Architectural Concept for Intrusion Tolerance in Air Traffic Networks
NASA Technical Reports Server (NTRS)
Maddalon, Jeffrey M.; Miner, Paul S.
2003-01-01
The goal of an intrusion tolerant network is to continue to provide predictable and reliable communication in the presence of a limited num ber of compromised network components. The behavior of a compromised network component ranges from a node that no longer responds to a nod e that is under the control of a malicious entity that is actively tr ying to cause other nodes to fail. Most current data communication ne tworks do not include support for tolerating unconstrained misbehavio r of components in the network. However, the fault tolerance communit y has developed protocols that provide both predictable and reliable communication in the presence of the worst possible behavior of a limited number of nodes in the system. One may view a malicious entity in a communication network as a node that has failed and is behaving in an arbitrary manner. NASA/Langley Research Center has developed one such fault-tolerant computing platform called SPIDER (Scalable Proces sor-Independent Design for Electromagnetic Resilience). The protocols and interconnection mechanisms of SPIDER may be adapted to large-sca le, distributed communication networks such as would be required for future Air Traffic Management systems. The predictability and reliabi lity guarantees provided by the SPIDER protocols have been formally v erified. This analysis can be readily adapted to similar network stru ctures.
Hayes, Robert
2004-10-01
In most nuclear facilities, fixed air samplers and sometimes portable air samplers are used where some probability of a release exists but is not expected, and so the added expense and effort of using a continuous air monitor is not deemed justified. When a release is suspected, naturally occurring radioactive material buildup on the filter typically prevents any quantitative measurements within the first day or so. Likewise, outdoor air measurements suffer from the same limitations (such as those taken during the Los Alamos fires) and so any rapid quantifiable measurements of fixed air sampler/portable air sampler filters which are technically defendable (even though conservative) are of use. The technique presented here is only intended for use in routine health physics survey applications and does not presently appear to be appropriate for sub pico Curie activity determinations. This study evaluates the utility of using a portable continuous air monitor as an alpha spectrometer to make transuranic activity determinations of samples using both the built in algorithm for air monitoring and a simple region of interest analysis. All samples evaluated were from air sample filters taken using a portable air sampler. Samples were taken over many months to quantify effects from natural variation in radon progeny activity distributions.
Defining Nitrogen Kinetics for Air Break in Prebreathe
NASA Technical Reports Server (NTRS)
Conkin, Johnny
2009-01-01
Actual tissue nitrogen (N2) kinetics are complex; the uptake and elimination is often approximated with a single half-time compartment in statistical descriptions of denitrogenation [prebreathe (PB)] protocols. Air breaks during PB complicate N2 kinetics. A comparison of symmetrical versus asymmetrical N2 kinetics was performed using the time to onset of hypobaric decompression sickness (DCS) as a surrogate for actual venous N2 tension. Published results of 12 tests involving 179 hypobaric exposures in altitude chambers after PB, with and without air breaks, provide the complex protocols from which to model N2 kinetics. DCS survival time for combined control and air breaks were described with an accelerated log logistic model where N2 uptake and elimination before, during, and after the air break was computed with a simple exponential function or a function that changed half-time depending on ambient N2 partial pressure. P1N2-P2 = delta P defined DCS dose for each altitude exposure, where P2 was the test altitude and P1N2 was computed N2 pressure at the beginning of the altitude exposure. The log likelihood (LL) without DCS dose (null model) was -155.6, and improved (best-fit) to -97.2 when dose was defined with a 240 min half-time for both N2 elimination and uptake during the PB. The description of DCS survival time was less precise with asymmetrical N2 kinetics, for example, LL was -98.9 with 240 min half-time elimination and 120 min half-time uptake. The statistical regression described survival time mechanistically linked to symmetrical N2 kinetics during PBs that also included air breaks. The results are data-specific, and additional data may change the conclusion. The regression is useful to compute additional PB time to compensate for an air break in PB within the narrow range of tested conditions.
Shiratake, Takuma; Sato, Atsushi; Minoda, Ayumi; Tsuzuki, Mikio; Sato, Norihiro
2013-01-01
Triacylglycerol is used for the production of commodities including food oils and biodiesel fuel. Microalgae can accumulate triacylglycerol under adverse environmental conditions such as nitrogen-starvation. This study explored the possibility of air-drying of green algal cells as a novel and simple protocol for enhancement of their triacylglycerol content. Chlorella kessleri cells were fixed on the surface of a glass fibre filter and then subjected to air-drying with light illumination. The dry cell weight, on a filter, increased by 2.7-fold in 96 h, the corresponding chlorophyll content ranging from 1.0 to 1.3-fold the initial one. Concomitantly, the triacylglycerol content remarkably increased to 70.3 mole% of fatty acids and 15.9% (w/w), relative to total fatty acids and dry cell weight, respectively, like in cells starved of nitrogen. Reduction of the stress of air-drying by placing the glass filter on a filter paper soaked in H2O lowered the fatty acid content of triacylglycerol to 26.4 mole% as to total fatty acids. Moreover, replacement of the H2O with culture medium further decreased the fatty acid content of triacylglycerol to 12.2 mole%. It thus seemed that severe dehydration is required for full induction of triacylglycerol synthesis, and that nutritional depletion as well as dehydration are crucial environmental factors. Meanwhile, air-drying of Chlamydomonas reinhardtii cells increased the triacylglycerol content to only 37.9 mole% of fatty acids and 4.8% (w/w), relative to total fatty acids and dry cell weight, respectively, and a marked decrease in the chlorophyll content, on a filter, of 33%. Air-drying thus has an impact on triacylglycerol synthesis in C. reinhardtii also, however, the effect is considerably limited, owing probably to instability of the photosynthetic machinery. This air-drying protocol could be useful for the development of a system for industrial production of triacylglycerol with appropriate selection of the algal species.
Quansah, Reginald; Ochieng, Caroline A; Semple, Sean; Juvekar, Sanjar; Emina, Jacques; Armah, Frederick Ato; Luginaah, Isaac
2015-03-04
Indoor air pollution (IAP) interventions are widely promoted as a means of reducing indoor air pollution/health from solid fuel use; and research addressing impact of these interventions has increased substantially in the past two decades. It is timely and important to understand more about effectiveness of these interventions. We describe the protocol of a systematic review to (i) evaluate effectiveness of IAP interventions to improve indoor air quality and/or health in homes using solid fuel for cooking and/or heating in lower- and middle-income countries, (ii) identify the most effective intervention to improve indoor air quality and/or health, and (iii) identify future research needs. This review will be conducted according to the National Institute for Health and Care Excellence (NICE) guidelines and will be reported following the PRISMA statement. Ovid MEDLINE, Ovid Embase, SCOPUS, and PubMed searches were conducted in September 2013 and updated in November 2014 (and include any further search updates in February 2015). Additional references will be located through searching the references cited by identified studies and through the World Health Organization Global database of household air pollution measurements. We will also search our own archives. Data extraction and risk of bias assessment of all included papers will be conducted independently by five reviewers. The study will provide insights into what interventions are most effective in reducing indoor air pollution and/or adverse health outcomes in homes using solid fuel for cooking or heating in lower- or middle-income countries. The findings from this review will be used to inform future IAP interventions and policy on poverty reduction and health improvement in poor communities who rely on biomass and solid fuels for cooking and heating. The review has been registered with PROSPERO (registration number CRD42014009768 ).
Snyder-Mackler, Noah; Majoros, William H.; Yuan, Michael L.; Shaver, Amanda O.; Gordon, Jacob B.; Kopp, Gisela H.; Schlebusch, Stephen A.; Wall, Jeffrey D.; Alberts, Susan C.; Mukherjee, Sayan; Zhou, Xiang; Tung, Jenny
2016-01-01
Research on the genetics of natural populations was revolutionized in the 1990s by methods for genotyping noninvasively collected samples. However, these methods have remained largely unchanged for the past 20 years and lag far behind the genomics era. To close this gap, here we report an optimized laboratory protocol for genome-wide capture of endogenous DNA from noninvasively collected samples, coupled with a novel computational approach to reconstruct pedigree links from the resulting low-coverage data. We validated both methods using fecal samples from 62 wild baboons, including 48 from an independently constructed extended pedigree. We enriched fecal-derived DNA samples up to 40-fold for endogenous baboon DNA and reconstructed near-perfect pedigree relationships even with extremely low-coverage sequencing. We anticipate that these methods will be broadly applicable to the many research systems for which only noninvasive samples are available. The lab protocol and software (“WHODAD”) are freely available at www.tung-lab.org/protocols-and-software.html and www.xzlab.org/software.html, respectively. PMID:27098910
Complete Prevention of Dendrite Formation in Zn Metal Anodes by Means of Pulsed Charging Protocols.
Garcia, Grecia; Ventosa, Edgar; Schuhmann, Wolfgang
2017-06-07
Zn metal as anode in rechargeable batteries, such as Zn/air or Zn/Ni, suffers from poor cyclability. The formation of Zn dendrites upon cycling is the key limiting step. We report a systematic study of the influence of pulsed electroplating protocols on the formation of Zn dendrites and in turn on strategies to completely prevent Zn dendrite formation. Because of the large number of variables in electroplating protocols, a scanning droplet cell technique was adapted as a high-throughput methodology in which a descriptor of the surface roughness can be in situ derived by means of electrochemical impedance spectroscopy. Upon optimizing the electroplating protocol by controlling nucleation, zincate ion depletion, and zincate ion diffusion, scanning electron microscopy and atomic force microscopy confirmed the growth of uniform and homogenous Zn deposits with a complete prevention of dendrite growth. The implementation of pulsed electroplating as the charging protocol for commercially available Ni-Zn batteries leads to substantially prolonged cyclability demonstrating the benefits of pulsed charging in Zn metal-based batteries.
Preventing disease transmission by deceased tissue donors by testing blood for viral nucleic acid.
Strong, D Michael; Nelson, Karen; Pierce, Marge; Stramer, Susan L
2005-01-01
Nucleic acid testing (NAT) has reduced the risk of transmitting infectious disease through blood transfusion. Currently NAT for HIV-1 and HCV are FDA licensed and performed by nearly all blood collection facilities, but HBV NAT is performed under an investigational study protocol. Residual risk estimates indicate that NAT could potentially reduce disease transmission through transplanted tissue. However, tissue donor samples obtained post-mortem have the potential to produce an invalid NAT result due to inhibition of amplification reactions by hemolysis and other factors. The studies reported here summarize the development of protocols to allow NAT of deceased donor samples with reduced rates of invalid results. Using these protocols, inventories from two tissue centers were tested with greater than 99% of samples producing a valid test result.
Geochemical and mineralogical data for soils of the conterminous United States
Smith, David B.; Cannon, William F.; Woodruff, Laurel G.; Solano, Federico; Kilburn, James E.; Fey, David L.
2013-01-01
In 2007, the U.S. Geological Survey initiated a low-density (1 site per 1,600 square kilometers, 4,857 sites) geochemical and mineralogical survey of soils of the conterminous United States as part of the North American Soil Geochemical Landscapes Project. Sampling and analytical protocols were developed at a workshop in 2003, and pilot studies were conducted from 2004 to 2007 to test and refine these recommended protocols. The final sampling protocol for the national-scale survey included, at each site, a sample from a depth of 0 to 5 centimeters, a composite of the soil A horizon, and a deeper sample from the soil C horizon or, if the top of the C horizon was at a depth greater than 1 meter, from a depth of approximately 80–100 centimeters. The <2-millimeter fraction of each sample was analyzed for a suite of 45 major and trace elements by methods that yield the total or near-total elemental content. The major mineralogical components in the samples from the soil A and C horizons were determined by a quantitative X-ray diffraction method using Rietveld refinement. Sampling in the conterminous United States was completed in 2010, with chemical and mineralogical analyses completed in May 2013. The resulting dataset provides an estimate of the abundance and spatial distribution of chemical elements and minerals in soils of the conterminous United States and represents a baseline for soil geochemistry and mineralogy against which future changes may be recognized and quantified. This report (1) describes the sampling, sample preparation, and analytical methods used; (2) gives details of the quality control protocols used to monitor the quality of chemical and mineralogical analyses over approximately six years; and (3) makes available the soil geochemical and mineralogical data in downloadable tables.
Bioaerosol DNA Extraction Technique from Air Filters Collected from Marine and Freshwater Locations
NASA Astrophysics Data System (ADS)
Beckwith, M.; Crandall, S. G.; Barnes, A.; Paytan, A.
2015-12-01
Bioaerosols are composed of microorganisms suspended in air. Among these organisms include bacteria, fungi, virus, and protists. Microbes introduced into the atmosphere can drift, primarily by wind, into natural environments different from their point of origin. Although bioaerosols can impact atmospheric dynamics as well as the ecology and biogeochemistry of terrestrial systems, very little is known about the composition of bioaerosols collected from marine and freshwater environments. The first step to determine composition of airborne microbes is to successfully extract environmental DNA from air filters. We asked 1) can DNA be extracted from quartz (SiO2) air filters? and 2) how can we optimize the DNA yield for downstream metagenomic sequencing? Aerosol filters were collected and archived on a weekly basis from aquatic sites (USA, Bermuda, Israel) over the course of 10 years. We successfully extracted DNA from a subsample of ~ 20 filters. We modified a DNA extraction protocol (Qiagen) by adding a beadbeating step to mechanically shear cell walls in order to optimize our DNA product. We quantified our DNA yield using a spectrophotometer (Nanodrop 1000). Results indicate that DNA can indeed be extracted from quartz filters. The additional beadbeating step helped increase our yield - up to twice as much DNA product was obtained compared to when this step was omitted. Moreover, bioaerosol DNA content does vary across time. For instance, the DNA extracted from filters from Lake Tahoe, USA collected near the end of June decreased from 9.9 ng/μL in 2007 to 3.8 ng/μL in 2008. Further next-generation sequencing analysis of our extracted DNA will be performed to determine the composition of these microbes. We will also model the meteorological and chemical factors that are good predictors for microbial composition for our samples over time and space.
Leaderer, B P; Zagraniski, R T; Berwick, M; Stolwijk, J A
1986-08-01
A methodology for assessing indoor air pollutant exposures is presented, with specific application to unvented combustion by-products. This paper describes the method as applied to a study of acute respiratory illness associated with the use of unvented kerosene space heaters in 333 residences in the New Haven, Connecticut, area from September 1982 to April 1983. The protocol serves as a prototype for a nested design of exposure assessment which could be applied to large-scale field studies of indoor air contaminant levels. Questionnaires, secondary records, and several methods of air monitoring offer a reliable method of estimating environmental exposures for assessing associations with health effects at a reasonable cost. Indoor to outdoor ratios of NO2 concentrations were found to be 0.58 +/- 0.31 for residences without known sources of NO2. Levels of NO2 were found to be comparable for homes with a kerosene heater only and those with a gas cooking stove only. Homes with a kerosene heater and a gas stove had average two-week NO2 levels approximately double those with only one source. Presence of tobacco smokers had a small but significant impact on indoor NO2 levels. Two-week average levels of indoor NO2 were found to be excellent predictors of total personal NO2 exposure for a small sample of adults. Residences with kerosene space heaters had SO2 levels corresponding to the number of hours of heater use and the sulfur content of the fuel. Formaldehyde levels were found to be low and not related to unvented combustion sources. NO2, SO2, and CO2 levels measured in some of the residences were found to exceed those levels specified in current national health standards.
Woolfenden, Elizabeth
2010-04-16
Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents current state-of-the-art and recent developments in relevant areas such as sorbent research, sampler design, enhanced approaches to analytical quality assurance and on-tube derivatisation. Copyright 2009 Elsevier B.V. All rights reserved.
Molecular detection of airborne Coccidioides in Tucson, Arizona
Chow, Nancy A.; Griffin, Dale W.; Barker, Bridget M.; Loparev, Vladimir N.; Litvintseva, Anastasia P.
2016-01-01
Environmental surveillance of the soil-dwelling fungus Coccidioides is essential for the prevention of Valley fever, a disease primarily caused by inhalation of the arthroconidia. Methods for collecting and detectingCoccidioides in soil samples are currently in use by several laboratories; however, a method utilizing current air sampling technologies has not been formally demonstrated for the capture of airborne arthroconidia. In this study, we collected air/dust samples at two sites (Site A and Site B) in the endemic region of Tucson, Arizona, and tested a variety of air samplers and membrane matrices. We then employed a single-tube nested qPCR assay for molecular detection. At both sites, numerous soil samples (n = 10 at Site A and n = 24 at Site B) were collected and Coccidioides was detected in two samples (20%) at Site A and in eight samples (33%) at Site B. Of the 25 air/dust samples collected at both sites using five different air sampling methods, we detected Coccidioides in three samples from site B. All three samples were collected using a high-volume sampler with glass-fiber filters. In this report, we describe these methods and propose the use of these air sampling and molecular detection strategies for environmental surveillance of Coccidioides.
Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance
2011-09-01
Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.
Regan, John Frederick
2014-09-09
Removable cartridges are used on automated flow-through systems for the purpose of extracting and purifying genetic material from complex matrices. Different types of cartridges are paired with specific automated protocols to concentrate, extract, and purifying pathogenic or human genetic material. Their flow-through nature allows large quantities sample to be processed. Matrices may be filtered using size exclusion and/or affinity filters to concentrate the pathogen of interest. Lysed material is ultimately passed through a filter to remove the insoluble material before the soluble genetic material is delivered past a silica-like membrane that binds the genetic material, where it is washed, dried, and eluted. Cartridges are inserted into the housing areas of flow-through automated instruments, which are equipped with sensors to ensure proper placement and usage of the cartridges. Properly inserted cartridges create fluid- and air-tight seals with the flow lines of an automated instrument.
Design of the aerosol sampling manifold for the Southern Great Plains site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leifer, R.; Knuth, R.H.; Guggenheim, S.F.
1995-04-01
To meet the needs of the ARM program, the Environmental Measurements Laboratory (EML) has the responsibility to establish a surface aerosol measurements program at the Southern Great Plains (SGP) site in Lamont, OK. At the present time, EML has scheduled installation of five instruments at SGP: a single wavelength nephelometer, an optical particle counter (OPC), a condensation particle counter (CPC), an optical absorption monitor (OAM), and an ozone monitor. ARM`s operating protocol requires that all the observational data be placed online and sent to the main computer facility in real time. EML currently maintains a computer file containing back trajectorymore » (BT) analyses for the SGP site. These trajectories are used to characterize air mass types as they pass over the site. EML is continuing to calculate and store the resulting trajectory analyses for future use by the ARM science team.« less
NASA Technical Reports Server (NTRS)
James, John T.
2001-01-01
The toxicological assessment of air samples returned at the end of the STS-l04 (7 A) flight to the ISS is reported. ISS air samples were taken in June and July 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Atlantis using GSCs. Solid sorbent air sampler (SSAS) samples were obtained from the ISS in April, June, and July. Analytical methods have not changed from earlier reports, and all quality control measures were met.
Anti-malarial drug quality in Lagos and Accra - a comparison of various quality assessments
2010-01-01
Background Two major cities in West Africa, Accra, the capital of Ghana, and Lagos, the largest city of Nigeria, have significant problems with substandard pharmaceuticals. Both have actively combated the problem in recent years, particularly by screening products on the market using the Global Pharma Health Fund e.V. Minilab® protocol. Random sampling of medicines from the two cities at least twice over the past 30 months allows a tentative assessment of whether improvements in drug quality have occurred. Since intelligence provided by investigators indicates that some counterfeit producers may be adapting products to pass Minilab tests, the results are compared with those from a Raman spectrometer and discrepancies are discussed. Methods Between mid-2007 and early-2010, samples of anti-malarial drugs were bought covertly from pharmacies in Lagos on three different occasions (October 2007, December 2008, February 2010), and from pharmacies in Accra on two different occasions (October 2007, February 2010). All samples were tested using the Minilab® protocol, which includes disintegration and active ingredient assays as well as visual inspection, and most samples were also tested by Raman spectrometry. Results In Lagos, the failure rate in the 2010 sampling fell to 29% of the 2007 finding using the Minilab® protocol, 53% using Raman spectrometry, and 46% using visual inspection. In Accra, the failure rate in the 2010 sampling fell to 54% of the 2007 finding using the Minilab® protocol, 72% using Raman spectrometry, and 90% using visual inspection. Conclusions The evidence presented shows that drug quality is probably improving in both cities, especially Lagos, since major reductions of failure rates over time occur with all means of assessment. Many more samples failed when examined by Raman spectrometry than by Minilab® protocol. The discrepancy is most likely caused by the two techniques measuring different aspects of the medication and hence the discrepancy may be the natural variation in these techniques. But other explanations are possible and are discussed. PMID:20537190
HEALTH-SCREENING PROTOCOLS FOR VINACEOUS AMAZONS (AMAZONA VINACEA) IN A REINTRODUCTION PROJECT.
Saidenberg, André B S; Zuniga, Eveline; Melville, Priscilla A; Salaberry, Sandra; Benites, Nilson R
2015-12-01
Reintroduction is a growing field in the conservation of endangered species. The vinaceous Amazon parrot (Amazona vinacea) is extinct in several areas, and a project to release confiscated individuals to their former range is currently underway. The objective of this study was to evaluate and improve the selection and treatment of individual release candidates by detecting possible pathogen carriers using samples taken before and during release. As part of prerelease health protocols, samples were obtained from 29 parrots on three different occasions while in captivity and once after their release. Samples were screened for paramyxovirus type 1, avian influenza, poxvirus, coronavirus, psittacine herpesvirus 1, Chlamydia psittaci , enteropathogenic Escherichia coli (EPEC), Salmonella spp., and endoparasites. The majority of samples returned negative results, with the exception of two individuals that tested positive for C. psittaci in the first sampling and for Ascaridia spp. in the second pooled sampling. Treatments for C. psittaci and endoparasites were administered prior to release, and negative results were obtained in subsequent exams. The number of positive results for E. coli (non-EPEC) decreased during the rehabilitation period. Adequate quarantine procedures and health examinations greatly minimize disease risks. The protocols employed in this study resulted in acceptable health status in accordance with current environmental legislation in Brazil. Additionally, protocols allowed informed decisions to release candidates, minimized risks, and favored the selection of healthy individuals, thereby contributing to the recovery of this species. It is important to determine appropriate minimum health-screening protocols when advanced diagnostics may not be available or high costs make the tests prohibitive in countries where confiscations occur. We hypothesize that a minimum panel of tests of pooled samples can serve as an alternative approach that minimizes costs and overall workload and supports projects intended to restore and promote flagship species and hamper their illegal trade.
Human immunodeficiency virus bDNA assay for pediatric cases.
Avila, M M; Liberatore, D; Martínez Peralta, L; Biglione, M; Libonatti, O; Coll Cárdenas, P; Hodara, V L
2000-01-01
Techniques to quantify plasma HIV-1 RNA viral load (VL) are commercially available, and they are adequate for monitoring adults infected by HIV and treated with antiretroviral drugs. Little experience on HIV VL has been reported in pediatric cases. In Argentina, the evaluation of several assays for VL in pediatrics are now being considered. To evaluate the pediatric protocol for bDNA assay in HIV-infected children, 25 samples from HIV-infected children (according to CDC criteria for pediatric AIDS) were analyzed by using Quantiplex HIV RNA 2.0 Assay (Chiron Corporation) following the manufacturer's recommendations in a protocol that uses 50 microliters of patient's plasma (sensitivity: 10,000 copies/ml). When HIV-RNA was not detected, samples were run with the 1 ml standard bDNA protocol (sensitivity: 500 HIV-RNA c/ml). Nine samples belonged to infants under 12 months of age (group A) and 16 were over 12 months (group B). All infants under one year of age had high HIV-RNA copies in plasma. VL ranged from 30,800 to 2,560,000 RNA copies/ml (median = 362,000 c/ml) for group A and < 10,000 to 554,600 c/ml (median = < 10,000) for group B. Only 25% of children in group B had detectable HIV-RNA. By using the standard test of quantification, none of the patients had non detectable HIV-RNA, ranging between 950 and 226,200 c/ml for group B (median = 23,300 RNA c/ml). The suggested pediatric protocol could be useful in children under 12 months of age, but 1 ml standard protocol must be used for older children. Samples with undetectable results from children under one year of age should be repeated using the standard protocol.
Bayesian adaptive survey protocols for resource management
Halstead, Brian J.; Wylie, Glenn D.; Coates, Peter S.; Casazza, Michael L.
2011-01-01
Transparency in resource management decisions requires a proper accounting of uncertainty at multiple stages of the decision-making process. As information becomes available, periodic review and updating of resource management protocols reduces uncertainty and improves management decisions. One of the most basic steps to mitigating anthropogenic effects on populations is determining if a population of a species occurs in an area that will be affected by human activity. Species are rarely detected with certainty, however, and falsely declaring a species absent can cause improper conservation decisions or even extirpation of populations. We propose a method to design survey protocols for imperfectly detected species that accounts for multiple sources of uncertainty in the detection process, is capable of quantitatively incorporating expert opinion into the decision-making process, allows periodic updates to the protocol, and permits resource managers to weigh the severity of consequences if the species is falsely declared absent. We developed our method using the giant gartersnake (Thamnophis gigas), a threatened species precinctive to the Central Valley of California, as a case study. Survey date was negatively related to the probability of detecting the giant gartersnake, and water temperature was positively related to the probability of detecting the giant gartersnake at a sampled location. Reporting sampling effort, timing and duration of surveys, and water temperatures would allow resource managers to evaluate the probability that the giant gartersnake occurs at sampled sites where it is not detected. This information would also allow periodic updates and quantitative evaluation of changes to the giant gartersnake survey protocol. Because it naturally allows multiple sources of information and is predicated upon the idea of updating information, Bayesian analysis is well-suited to solving the problem of developing efficient sampling protocols for species of conservation concern.
Gibbs, Jenna L; Yost, Michael G; Negrete, Maria; Fenske, Richard A
2017-03-01
Recent studies have highlighted the increased potency of oxygen analogs of organophosphorus pesticides. These pesticides and oxygen analogs have previously been identified in the atmosphere following spray applications in the states of California and Washington. We used two passive sampling methods to measure levels of the ollowing organophosphorus pesticides: chlorpyrifos, azinphos-methyl, and their oxygen analogs at 14 farmworker and 9 non-farmworker households in an agricultural region of central Washington State in 2011. The passive methods included polyurethane foam passive air samplers deployed outdoors and indoors and polypropylene deposition plates deployed indoors. We collected cumulative monthly samples during the pesticide application seasons and during the winter season as a control. Monthly outdoor air concentrations ranged from 9.2 to 199 ng/m 3 for chlorpyrifos, 0.03 to 20 ng/m 3 for chlorpyrifos-oxon, < LOD (limit of detection) to 7.3 ng/m 3 for azinphos-methyl, and < LOD to 0.8 ng/m 3 for azinphos-methyl-oxon. Samples from proximal households (≤ 250 m) had significantly higher outdoor air concentrations of chlorpyrifos, chlorpyrifos-oxon, and azinphos-methyl than did samples from nonproximal households ( p ≤ 0.02). Overall, indoor air concentrations were lower than outdoors. For example, all outdoor air samples for chlorpyrifos and 97% of samples for azinphos-methyl were > LOD. Indoors, only 78% of air samples for chlorpyrifos and 35% of samples for azinphos-methyl were > LOD. Samples from farmworker households had higher indoor air concentrations of both pesticides than did samples from non-farmworker households. Mean indoor and outdoor air concentration ratios for chlorpyrifos and azinphos-methyl were 0.17 and 0.44, respectively. We identified higher levels in air and on surfaces at both proximal and farmworker households. Our findings further confirm the presence of pesticides and their oxygen analogs in air and highlight their potential for infiltration of indoor living environments. Citation: Gibbs JL, Yost MG, Negrete M, Fenske RA. 2017. Passive sampling for indoor and outdoor exposures to chlorpyrifos, azinphos-methyl, and oxygen analogs in a rural agricultural community. Environ Health Perspect 125:333-341; http://dx.doi.org/10.1289/EHP425.
Tobin, John
1989-01-01
A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.
2013-01-01
Background Pure 1, 3-diacylglycerols (1, 3-DAG) have been considered to be significant surfactants in food, cosmetics and pharmaceutical industries, as well as the effect on obesity prevention. Methods In this study, a vacuum-driven air bubbling operation mode was developed and evaluated for the enzymatic synthesis of 1, 3-DAG of saturated fatty acids, by direct esterification of glycerol with fatty acids in a solvent-free system. The employed vacuum-driven air bubbling operation mode was comparable to vacuum-driven N2 bubbling protocol, in terms of lauric acid conversion and 1, 3-dilaurin content. Results Some operation parameters were optimized, and 95.3% of lauric acid conversion and 80.3% of 1, 3-dilaurin content was obtained after 3-h reaction at 50°C, with 5 wt% of Lipozyme RM IM (based on reactants) amount. Of the lipases studied, both Lipozyme RM IM and Novozym 435 exhibited good performance in terms of lauric acid conversion. Lipozyme TL IM, however, showed low activity. Lipozyme RM IM showed good operational stability in this operation protocol, 80.2% of the original catalytic activity remained after 10 consecutive batch applications. Some other 1, 3-DAG were prepared and high content was obtained after purification: 98.5% for 1, 3-dicaprylin, 99.2% for 1, 3-dicaprin, 99.1% for 1, 3-dilaurin, 99.5 for 1, 3-dipalmitin and 99.4% for 1, 3-disterin. Conclusion The established vacuum-driven air bubbling operation protocol had been demonstrated to be a simple-operating, cost-effective, application practical and efficient methodology for 1, 3-DAG preparation. PMID:23656739
HSRP and HSRP Partner Analytical Methods and Protocols
HSRP has worked with various partners to develop and test analytical methods and protocols for use by laboratories charged with analyzing environmental and/or buildling material samples following contamination incident.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-01-01
This volume is one in a series of manuals prepared for EPA to assist its Remedial Project Managers in the assessment of the air contaminant pathway and developing input data for risk assessment. The manual provides guidance on developing baseline-emission estimates from hazardous waste sites. Baseline-emission estimates (BEEs) are defined as emission rates estimated for a site in its undisturbed state. Specifically, the manual is intended to: Present a protocol for selecting the appropriate level of effort to characterize baseline air emissions; Assist site managers in designing an approach for BEEs; Describe useful technologies for developing site-specific baseline emission estimatesmore » (BEEs); Help site managers select the appropriate technologies for generating site-specific BEEs.« less
Bobaly, Balazs; D'Atri, Valentina; Goyon, Alexandre; Colas, Olivier; Beck, Alain; Fekete, Szabolcs; Guillarme, Davy
2017-08-15
The analytical characterization of therapeutic monoclonal antibodies and related proteins usually incorporates various sample preparation methodologies. Indeed, quantitative and qualitative information can be enhanced by simplifying the sample, thanks to the removal of sources of heterogeneity (e.g. N-glycans) and/or by decreasing the molecular size of the tested protein by enzymatic or chemical fragmentation. These approaches make the sample more suitable for chromatographic and mass spectrometric analysis. Structural elucidation and quality control (QC) analysis of biopharmaceutics are usually performed at intact, subunit and peptide levels. In this paper, general sample preparation approaches used to attain peptide, subunit and glycan level analysis are overviewed. Protocols are described to perform tryptic proteolysis, IdeS and papain digestion, reduction as well as deglycosylation by PNGase F and EndoS2 enzymes. Both historical and modern sample preparation methods were compared and evaluated using rituximab and trastuzumab, two reference therapeutic mAb products approved by Food and Drug Administration (FDA) and European Medicines Agency (EMA). The described protocols may help analysts to develop sample preparation methods in the field of therapeutic protein analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Wong, Amy P; Chin, Stephanie; Xia, Sunny; Garner, Jodi; Bear, Christine E; Rossant, Janet
2015-03-01
Airway epithelial cells are of great interest for research on lung development, regeneration and disease modeling. This protocol describes how to generate cystic fibrosis (CF) transmembrane conductance regulator protein (CFTR)-expressing airway epithelial cells from human pluripotent stem cells (PSCs). The stepwise approach from PSC culture to differentiation into progenitors and then mature epithelia with apical CFTR activity is outlined. Human PSCs that were inefficient at endoderm differentiation using our previous lung differentiation protocol were able to generate substantial lung progenitor cell populations. Augmented CFTR activity can be observed in all cultures as early as at 35 d of differentiation, and full maturation of the cells in air-liquid interface cultures occurs in <5 weeks. This protocol can be used for drug discovery, tissue regeneration or disease modeling.
Air pollution effects on food quality. 2nd annual progress report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pell, E.J.
1979-02-01
Progress is reported in studies to determine the effect of acute, toxic exposures of ozone to alfalfa, potato, and soybean plants. The objective has been to correlate the foliar response with alterations in quality of the edible portion of the plant viz. the leaf, tuber and seed of alfalfa, potato and soybean, respectively. In 1977 we (1) modified our fumigation facilities, (2) developed protocol for studies with alfalfa and potato, and (3) conducted studies on flavonoid status of alfalfa and a series of parameters of potato tubers. In 1978 we (1) conducted more indepth studies with alfalfa, (2) repeated themore » potato study, (3) began to develop protocol for measuring additional parameters of alfalfa and potato quality, and (4) developed protocol for cultivating and exposing soybean plants.« less
Forced-Air Warming Discontinued: Periprosthetic Joint Infection Rates Drop.
Augustine, Scott D
2017-06-23
Several studies have shown that the waste heat from forced-air warming (FAW) escapes near the floor and warms the contaminated air resident near the floor. The waste heat then forms into convection currents that rise up and contaminate the sterile field above the surgical table. It has been shown that a single airborne bacterium can cause a periprosthetic joint infection (PJI) following joint replacement surgery. We retrospectively compared PJI rates during a period of FAW to a period of air-free conductive fabric electric warming (CFW) at three hospitals. Surgical and antibiotic protocols were held constant. The pooled multicenter data showed a decreased PJI rate of 78% following the discontinuation of FAW and a switch to air-free CFW (n=2034; P=0.002). The 78% reduction in joint implant infections observed when FAW was discontinued suggests that there is a link between the waste FAW heat and PJIs.
Forced-Air Warming Discontinued: Periprosthetic Joint Infection Rates Drop
Augustine, Scott D.
2017-01-01
Several studies have shown that the waste heat from forced-air warming (FAW) escapes near the floor and warms the contaminated air resident near the floor. The waste heat then forms into convection currents that rise up and contaminate the sterile field above the surgical table. It has been shown that a single airborne bacterium can cause a periprosthetic joint infection (PJI) following joint replacement surgery. We retrospectively compared PJI rates during a period of FAW to a period of air-free conductive fabric electric warming (CFW) at three hospitals. Surgical and antibiotic protocols were held constant. The pooled multicenter data showed a decreased PJI rate of 78% following the discontinuation of FAW and a switch to air-free CFW (n=2034; P=0.002). The 78% reduction in joint implant infections observed when FAW was discontinued suggests that there is a link between the waste FAW heat and PJIs. PMID:28713524
NASA Technical Reports Server (NTRS)
Amonlirdviman, Keith; Farley, Todd C.; Hansman, R. John, Jr.; Ladik, John F.; Sherer, Dana Z.
1998-01-01
A distributed real-time simulation of the civil air traffic environment developed to support human factors research in advanced air transportation technology is presented. The distributed environment is based on a custom simulation architecture designed for simplicity and flexibility in human experiments. Standard Internet protocols are used to create the distributed environment, linking all advanced cockpit simulator, all Air Traffic Control simulator, and a pseudo-aircraft control and simulation management station. The pseudo-aircraft control station also functions as a scenario design tool for coordinating human factors experiments. This station incorporates a pseudo-pilot interface designed to reduce workload for human operators piloting multiple aircraft simultaneously in real time. The application of this distributed simulation facility to support a study of the effect of shared information (via air-ground datalink) on pilot/controller shared situation awareness and re-route negotiation is also presented.
Masuda, K; Ohta, M; Ohsuka, S; Matsuyama, M; Ashoori, M; Usami, T; Ito, M; Ueda, M; Kaneda, T
1994-03-01
An autoclavable air turbine handpiece, Air Flushing Clean System (AFCS) (Osada Electric Co., Ltd., Tokyo, Japan) was developed for use in dentistry with the objective of reducing cross-contamination. Its potential for bacterial contamination was investigated in vitro using two bacterial strains (Streptococcus mutants ATCC 25175 and Staphylococcus aureus FDA 209 P). In theory, this device should prevent cross-contamination of the internal water and air lines of the handpiece, by maintaining an internal positive pressure even after the turbine is stopped. In the present study, this AFCS device was found to reduce the bacterial contamination within the air turbine handpiece more effectively than the conventional handpiece used according to accepted protocol. The reduction of such contamination by the AFCS is in keeping with the recent objective of the American Dental Association to reduce cross-contamination during dental procedures.
Sequential air sampler system : its use by the Virginia Department of Highways & Transportation.
DOT National Transportation Integrated Search
1975-01-01
The Department of Highways & Transportation needs an economical and efficient air quality sampling system for meeting requirements on air monitoring for proposed projects located In critical areas. Two sequential air sampling systems, the ERAI and th...
Siegert, Wolfgang; Ganzer, Christian; Kluth, Holger; Rodehutscord, Markus
2018-06-01
A regression approach was applied to determine the influence of feed provisioning prior to digesta sampling on precaecal (pc) amino acid (AA) digestibility in broiler chickens. Soybean meal was used as an example test ingredient. Five feed-provisioning protocols were investigated, four with restricted provision and one with ad libitum provision. When provision was restricted, feed was provided for 30 min after a withdrawal period of 12 h. Digesta were sampled 1, 2, 4 and 6 h after feeding commenced. A diet containing 300 g maize starch/kg was prepared. Half or all the maize starch was replaced with soybean meal in two other diets. Average pc digestibility of all determined AA in the soybean meal was 86% for the 4 and 6-h protocols and 66% and 60% for the 2 and 1-h protocols, respectively. Average pc AA digestibility of soybean meal was 76% for ad libitum feed provision. Feed provisioning also influenced the determined variance. Variance in digestibility ranked in magnitude 1 h > ad libitum > 2 h > 6 h > 4 h for all AA. Owing to the considerable influence of feed-provisioning protocols found in this study, comparisons of pc AA digestibility between studies applying different protocols prior to digesta sampling must be treated with caution. Digestibility experiments aimed at providing estimates for practical feed formulation should use feed-provisioning procedures similar to those used in practice.
2010-03-16
Exceeded at ERP Soil and Groundwater Sites 86 A-2a. Identification of IRIS Chemicals of Interest on the ATSDR CERCLA Priority List of Hazardous...the Number (Bold Font) of Air Force ERP Samples in Which They Were Detected 317 A-4d. Air Force ERP Soil Samples: IRIS Chemicals of Interest...Ranked by the Number (Bold Font) of Air Force ERP Soil Samples in Which They Were Detected 333 A-4e. Air Force ERP Groundwater Samples: IRIS Chemicals of
William H. McWilliams; Charles D. Canham; Randall S. Morin; Katherine Johnson; Paul Roth; James A. Westfall
2012-01-01
The Forest Inventory and Analysis Program of the Northern Research Station (NRS-FIA) has implemented new Advance Tree Seedling Regeneration (ATSR) protocols that include measurements of seedlings down to 2 inches in height. The addition of ATSR protocols is part of an evaluation of NRS-FIA Phase 3 indicator variables to increase sampling intensity from 1/96,000 acres...
2016-05-25
tissue is critical to biology. Many factors determine optimal experimental design, including attainable localization precision, ultrastructural...both imaging modalities. Examples include: weak tissue preservation protocols resulting in poor ultrastructure, e.g. mitochondrial cristae membranes...tension effects during sample drying that may result in artifacts44. Samples dried in the presence of polyvinyl alcohol do not have the haziness
USDA-ARS?s Scientific Manuscript database
Two rapid immunomagnetic separation (IMS) protocols were evaluated to recover 1-2 log CFU/g inoculated E. coli O157:H7 from 30 different commercial, finished compost samples. Both protocols detected E. coli O157:H7 in compost samples; PCR techniques required the removal of inhibitors to reduce poss...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyndall, R.L.
1983-07-01
Air was sampled at the point of discharge and at short distances downwind and upwind from industrial and power-plant cooling towers. Both high-volume electrostatic and impinger type samplers were used. Concentrates of the air samples were analyzed for Legionnaires' Disease Bacteria (LDB). In some cases, the samples were also tested for the presence of free-living amoebae. The concentrations of LDB in the air samples were well below the minimal infectious dose for guinea pigs and precluded testing of the samples for infectious LDB. Results of LDB analysis were related to the meteorological conditions at the time of sampling. Generally, themore » concentrations of LDB in the air at the discharge of the cooling towers were 1 x 10/sup -6/ to 1 x 10/sup -7/ of that found in comparable volumes of tower basin water. During periods of high humidity and wind speed, LDB was detected in a few downwind samples and one upwind sample. One site with extensive construction and excavation activity had higher LDB concentrations in air samples relative to other sites. Nonpathogenic Naegleria were present in one of two air samples taken in the mist at the base of a natural-draft cooling tower.« less
Bioindicators in the MIDUS National Study: Protocol, Measures, Sample, and Comparative Context
Love, Gayle Dienberg; Seeman, Teresa E.; Weinstein, Maxine; Ryff, Carol D.
2010-01-01
Objectives MIDUS is a national study of health and aging among individuals aged 25 to 74 at baseline(1995/96). Longitudinal survey assessments (2004/05), were followed by biological assessments on a subsample aged 35–85. To facilitate public use, we describe the protocol, measures, and sample. Methods Respondents traveled to clinics for a two-day data collection protocol that included fasting blood specimens, 12-hour urine specimen, medical history, physical exam, bone densitometry, a laboratory challenge (heart rate variability, blood pressure, respiration, salivary cortisol). Results Response rates for the biological protocol (N = 1,255) were 39.3%, or 43.1% (adjusting for those who could not be located or contacted). Reasons for non-participation were travel, family obligations, and being too busy. Respondents were comparable to the recruitment pool on most demographic characteristics and health assessments. Discussion Strengths of the protocol vis-à-vis other similar studies include opportunities to link biological factors with diverse content from other MIDUS projects. PMID:20876364
Miller, J D; Haisley, P D; Reinhardt, J H
2000-09-01
We studied the extent and nature of fungal colonization of building materials in 58 naturally ventilated apartments that had suffered various kinds of water damage in relation to air sampling done before the physical inspections. The results of air samples from each apartment were compared by rank order of species with pooled data from outdoor air. Approximately 90% of the apartments that had significant amounts of fungi in wall cavities were identified by air sampling. There was no difference in the average fungal colony forming unit values per m3 between the 15 apartments with the most fungal contamination and the 15 with the least. In contrast, the prevalence of samples with fungal species significantly different than the pooled outdoor air between the more contaminated versus the less contaminated apartments was approximately 10-fold. We provide information on methods to document fungal contamination in buildings.
Paredes, R Madelaine; Tadaki, Douglas K; Sooter, Amanda; Gamboni, Fabia; Sheppard, Forest
2018-01-01
Immunophenotyping of whole blood (WB) by flow cytometry (FC) is used clinically to assess a patient's immune status and also in biomedical research. Current protocols recommend storage of immunolabeled samples at 4°C with FC analysis to be completed within seven days. This data acquisition window can be extended to up to one year post-labeling, but this requires cryopreservation of the samples at ultra-low temperatures (≤-80°C or in liquid nitrogen). In this study we optimized a standardized cryopreservation protocol to enable preservation of immunolabeled, human WB samples at -20°C for FC and tested its effectiveness after 0, 5, 15 or 30days. Analysis of stored samples shows that this protocol effectively preserves immunolabeled WB samples and that the duration of storage has no effect on morphology, viability or frequency of WB cell subpopulations, and that the intensity of fluorescent signal from labeled extracellular markers is fully preserved for at least 15days, and up to 30days for some markers. We demonstrate that using this protocol, we are able to differentiate resting versus activated WB cells as demonstrated by detection of significantly increased expression of CD11b by myeloid cells in WB samples pretreated with LPS (100μg/mL for 12h). Finally, we show that this method allows for labeling and detection of the intracellular cytokine (IL-8) up to 30days following cryopreservation from myeloid cells, in previously labeled and cryopreserved WB samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Muiños-Bühl, Anixa; González-Recio, Oscar; Muñoz, María; Óvilo, Cristina; García-Casco, Juan; Fernández, Ana I
2018-06-01
There is a growing interest in understanding the role of the gut microbiome on productive and meat quality-related traits in livestock species in order to develop new useful tools for improving pig production systems and industry. Faecal samples are analysed as a proxy of gut microbiota and here the selection of suitable protocols for faecal sampling and DNA isolation is a critical first step in order to obtain reliable results, even more to compare results obtained from different studies. The aim of the current study was to establish in a cost-effective way, using automated ribosomal intergenic spacer analysis technique, a protocol for porcine faecal sampling and storage at farm and slaughterhouse and to determine the most efficient microbiota DNA isolation kit among those most widely used. Operational Taxonomic Unit profiles were compared from Iberian pig faecal samples collected from rectum or ground, stored with liquid N 2 , room temperature or RNAlater, and processed with QIAamp DNA Stool (Qiagen), PowerFecal DNA Isolation (Mobio) or SpeedTools Tissue DNA extraction (Biotools) commercial kits. The results, focused on prokaryote sampling, based on DNA yield and quality, OTU number and Sørensen similarity Indexes, indicate that the recommended protocol for porcine faecal microbiome sampling at farm should include: the collection from porcine rectum to avoid contamination; the storage in liquid N 2 or even at room temperature, but not in RNAlater; and the isolation of microbiota DNA using PowerFecal DNA Isolation kit. These conditions provide more reliable DNA samples for further microbiome analysis.
Legionnaires' Disease Bacteria in power plant cooling systems: downtime report. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.
1985-04-01
Legionnaires' Disease Bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Groups A, B, and C Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 126 air samples collected. These were predominantly Group A Legionella (L. pneumophila, serogroups 1 to 6). All 12 positive samples had been collected in the vicinity of water boxes, condensers, detention ponds, and cooling towers during downtime operations where aerosolization of Legionella populations would be expected. None of the air samples yielded infectious Legionella when injected into guinea pigs. Detection of Legionella in air samples taken during downtime was significantly more likely than detection during normal operating conditions (p <0.01). 13 refs., 4 figs., 10 tabs.« less
Macdermid, Paul W; Miller, Matthew C; Fink, Philip W; Stannard, Stephen R
2017-11-01
Cross-country mountain bike suspension reportedly enhances comfort and performance through reduced vibration and impact exposure. This study analysed the effectiveness of three different front fork systems at damping accelerations during the crossing of three isolated obstacles (stairs, drop, and root). One participant completed three trials on six separate occasions in a randomised order using rigid, air-sprung, and carbon leaf-sprung forks. Performance was determined by time to cross obstacles, while triaxial accelerometers quantified impact exposure and damping response. Results identified significant main effect of fork type for performance time (p < 0.05). The air-sprung and leaf-sprung forks were significantly slower than the rigid forks for the stairs (p < 0.05), while air-sprung suspension was slower than the rigid for the root protocol (p < 0.05). There were no differences for the drop protocol (p < 0.05). Rigid forks reduced overall exposure (p < 0.05), specifically at the handlebars for the stairs and drop trials. More detailed analysis presented smaller vertical accelerations at the handlebar for air-sprung and leaf-sprung forks on the stairs (p < 0.05), and drop (p < 0.05) but not the root. As such, it appears that the suspension systems tested were ineffective at reducing overall impact exposure at the handlebar during isolated aspects of cross-country terrain features which may be influenced to a larger extent by rider technique.
Robust Sub-nanomolar Library Preparation for High Throughput Next Generation Sequencing.
Wu, Wells W; Phue, Je-Nie; Lee, Chun-Ting; Lin, Changyi; Xu, Lai; Wang, Rong; Zhang, Yaqin; Shen, Rong-Fong
2018-05-04
Current library preparation protocols for Illumina HiSeq and MiSeq DNA sequencers require ≥2 nM initial library for subsequent loading of denatured cDNA onto flow cells. Such amounts are not always attainable from samples having a relatively low DNA or RNA input; or those for which a limited number of PCR amplification cycles is preferred (less PCR bias and/or more even coverage). A well-tested sub-nanomolar library preparation protocol for Illumina sequencers has however not been reported. The aim of this study is to provide a much needed working protocol for sub-nanomolar libraries to achieve outcomes as informative as those obtained with the higher library input (≥ 2 nM) recommended by Illumina's protocols. Extensive studies were conducted to validate a robust sub-nanomolar (initial library of 100 pM) protocol using PhiX DNA (as a control), genomic DNA (Bordetella bronchiseptica and microbial mock community B for 16S rRNA gene sequencing), messenger RNA, microRNA, and other small noncoding RNA samples. The utility of our protocol was further explored for PhiX library concentrations as low as 25 pM, which generated only slightly fewer than 50% of the reads achieved under the standard Illumina protocol starting with > 2 nM. A sub-nanomolar library preparation protocol (100 pM) could generate next generation sequencing (NGS) results as robust as the standard Illumina protocol. Following the sub-nanomolar protocol, libraries with initial concentrations as low as 25 pM could also be sequenced to yield satisfactory and reproducible sequencing results.
Oliver, Stacy R.; Ngo, Jerry; Flores, Rebecca; Midyett, Jason; Meinardi, Simone; Carlson, Matthew K.; Rowland, F. Sherwood; Blake, Donald R.; Galassetti, Pietro R.
2011-01-01
Effective management of diabetes mellitus, affecting tens of millions of patients, requires frequent assessment of plasma glucose. Patient compliance for sufficient testing is often reduced by the unpleasantness of current methodologies, which require blood samples and often cause pain and skin callusing. We propose that the analysis of volatile organic compounds (VOCs) in exhaled breath can be used as a novel, alternative, noninvasive means to monitor glycemia in these patients. Seventeen healthy (9 females and 8 males, 28.0 ± 1.0 yr) and eight type 1 diabetic (T1DM) volunteers (5 females and 3 males, 25.8 ± 1.7 yr) were enrolled in a 240-min triphasic intravenous dextrose infusion protocol (baseline, hyperglycemia, euglycemia-hyperinsulinemia). In T1DM patients, insulin was also administered (using differing protocols on 2 repeated visits to separate the effects of insulinemia on breath composition). Exhaled breath and room air samples were collected at 12 time points, and concentrations of ∼100 VOCs were determined by gas chromatography and matched with direct plasma glucose measurements. Standard least squares regression was used on several subsets of exhaled gases to generate multilinear models to predict plasma glucose for each subject. Plasma glucose estimates based on two groups of four gases each (cluster A: acetone, methyl nitrate, ethanol, and ethyl benzene; cluster B: 2-pentyl nitrate, propane, methanol, and acetone) displayed very strong correlations with glucose concentrations (0.883 and 0.869 for clusters A and B, respectively) across nearly 300 measurements. Our study demonstrates the feasibility to accurately predict glycemia through exhaled breath analysis over a broad range of clinically relevant concentrations in both healthy and T1DM subjects. PMID:21467303
40 CFR 52.2039 - Interstate transport.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Portland shall comply with the following requirements: (1) Perform air modeling to demonstrate that... the effective date of the section 126 finding, submit to the EPA a modeling protocol that is... that includes all units at the Portland Generating Station in the modeling. (ii) Within 15 business...
40 CFR 52.2039 - Interstate transport.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Portland shall comply with the following requirements: (1) Perform air modeling to demonstrate that... the effective date of the section 126 finding, submit to the EPA a modeling protocol that is... that includes all units at the Portland Generating Station in the modeling. (ii) Within 15 business...
40 CFR 52.2039 - Interstate transport.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Portland shall comply with the following requirements: (1) Perform air modeling to demonstrate that... the effective date of the section 126 finding, submit to the EPA a modeling protocol that is... that includes all units at the Portland Generating Station in the modeling. (ii) Within 15 business...