Science.gov

Sample records for air sampling results

  1. East Mountain Area 1995 air sampling results

    SciTech Connect

    Deola, R.A.

    1996-09-01

    Ambient air samples were taken at two locations in the East Mountain Area in conjunction with thermal testing at the Lurance Canyon Burn Site (LCBS). The samples were taken to provide measurements of particulate matter with a diameter less than or equal to 10 micrometers (PM{sub 10}) and volatile organic compounds (VOCs). This report summarizes the results of the sampling performed in 1995. The results from small-scale testing performed to determine the potentially produced air pollutants in the thermal tests are included in this report. Analytical results indicate few samples produced measurable concentrations of pollutants believed to be produced by thermal testing. Recommendations for future air sampling in the East Mountain Area are also noted.

  2. DUS II SOIL GAS SAMPLING AND AIR INJECTION TEST RESULTS

    SciTech Connect

    Noonkester, J.; Jackson, D.; Jones, W.; Hyde, W.; Kohn, J.; Walker, R.

    2012-09-20

    Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected

  3. A new analysis system for whole air sampling: description and results from 2013 SENEX

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Gilman, J.; Dumas, M.; Hughes, D.; Jaksich, A.; Hatch, C. D.; Graus, M.; Warneke, C.; Apel, E. C.; Hornbrook, R. S.; Holloway, J. S.; De Gouw, J. A.

    2014-12-01

    Accurate measurement of volatile organic compounds (VOCs) in the troposphere is critical for the understanding of emissions and physical and chemical processes that can impact both air quality and climate. Airborne VOC measurements have proven especially challenging due to the requirement of both high sensitivity (pptv) and short sample collection times (≤15 s) to maximize spatial resolution and sampling frequency for targeted plume analysis. The use of stainless steel canisters to collect whole air samples (WAS) for post-flight analysis has been pioneered by the groups of D. Blake and E. Atlas [Blake et al., 1992; Atlas et al., 1993]. For the 2013 Southeast Nexus Study (SENEX), the NOAA ESRL CSD laboratory undertook WAS measurements for the first time. This required the construction of three new, highly-automated, and field-portable instruments designed to sample, analyze, and clean the canisters for re-use. Analysis was performed with a new custom-built gas chromatograph-mass spectrometer system. The instrument pre-concentrates analyte cryostatically into two parallel traps by means of a Stirling engine, a novel technique which obviates the need for liquid nitrogen to reach trapping temperatures of -175C. Here we present an evaluation of the retrieval of target VOC species from WAS canisters. We discuss the effects of humidity and sample age on the analyte, particularly upon C8+ alkane and aromatic species and biogenic species. Finally, we present results from several research flights during SENEX that targeted emissions from oil/natural gas production.

  4. A survey of recent results in passive sampling of water and air by semipermeable membrane devices

    USGS Publications Warehouse

    Prest, Harry F.; Huckins, James N.; Petty, Jimmie D.; Herve, Sirpa; Paasivirta, Jaakko; Heinonen, Pertti

    1995-01-01

    A survey is presented of some recent results for passive sampling of water and air for trace organic contaminants using lipid-filled semipermeable membrane devices (SPMDs). Results of water sampling for trace organochlorine compounds using simultaneously exposed SPMDs and the most universally applied biomonitor (bivalves) are discussed. In general, the total amounts of accumulated analytes available for analysis in bivalves and SPMDs were comparable. However, SPMD controls typically had negligible levels of contamination, which was not always the case for transplanted bivalves, even after prolonged depuration prior to exposure. In surveys of the spatial trends of organochlorines at a series of sites, data from bivalves and SPMDs provided the same picture of contaminant distribution and severity. An exception was ionizable contaminants such as the chlorinated phenolic compounds and their transformation products found in pulp mill effluents. In these cases the two monitoring approaches compliment each other, i.e. what is not found in bivalves appears in SPMDs and vice versa. SPMDs have also been applied in environments where biomonitoring is not feasible. SPMDs have shown their utility in studies of trace levels of polyaromatic hydrocarbons by locating and characterizing point sources. An example is given of their application to the calculation of contaminant half-lives from aqueous SPMD residues, a direct measurement of the persistence of contaminants in an environmental compartment. Similarly, results of air sampling with SPMDs in a relatively pristine coastal location are cited which reveal a tremendous enhancement in p,p′-DDE relative to open ocean values.

  5. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-02-17

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self

  6. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    SciTech Connect

    Langton, C. A.; Almond, P. M.

    2013-11-26

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO{sub 4}{sup -} in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O{sub 4}{sup -}, which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The

  7. Microbial Air and Surface Monitoring Results from International Space Station Samples

    NASA Technical Reports Server (NTRS)

    Ott, C. Mark; Bruce, Rebekah J.; Castro, Victoria A.; Novikova, Natalia D.; Pierson, D. L.

    2005-01-01

    Over the course of long-duration spaceflight, spacecraft develop a microbial ecology that directly interacts with the crew of the vehicle. While most microorganisms are harmless or beneficial to the inhabitants of the vehicle, the presence of medically significant organisms appearing in this semi-closed environment could adversely affect crew health and performance. The risk of exposure of the crew to medically significant organisms during a mission is estimated using information gathered during nominal and contingency environmental monitoring. Analysis of the air and surface microbiota in the habitable compartments of the International Space Station (ISS) over the last four years indicate a high presence of Staphylococcus species reflecting the human inhabitants of the vehicle. Generally, air and surface microbial concentrations are below system design specifications, suggesting a lower risk of contact infection or biodegradation. An evaluation of sample frequency indicates a decrease in the identification of new species, suggesting a lower potential for unknown microorganisms to be identified. However, the opportunistic pathogen, Staphylococcus aureus, has been identified in 3 of the last 5 air samples and 5 of the last 9 surface samples. In addition, 47% of the coagulase negative Staphylococcus species that were isolated from the crew, ISS, and its hardware were found to be methicillin resistance. In combination, these observations suggest the potential of methicillin resistant infectious agents over time.

  8. Results of a Self-Absorption Study on the Versapor 3000 47-mm Filters for Radioactive Particulate Air Stack Sampling

    SciTech Connect

    Barnett, J. Matthew; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-11-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor® 3000, 47-mm diameter) used at PNNL for self absorption effects. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Large error is associated with the sample filter analysis comparison and subsequently with the estimation of the absorption factor resulting in an inadequate method to estimate losses from self-absorption in the sample filter. The mass loading on the sample filter as determined after digestion and drying was ~0.08 mg cm-2; however, this value may not represent the total filter mass loading given that there may be undetermined losses associated with the digestion process. While it is difficult to determine how much material is imbedded in the filter, observations from the microscopy analysis indicate that the vast majority of the particles remain on the top of the filter. In comparing the results obtained, the continued use of 0.85 as a conservative correction factor is recommended.

  9. 3D Air Quality and the Clean Air Interstate Rule: Lagrangian Sampling of CMAQ Model Results to Aid Regional Accountability Metrics

    NASA Technical Reports Server (NTRS)

    Fairlie, T. D.; Szykman, Jim; Pierce, Robert B.; Gilliland, A. B.; Engel-Cox, Jill; Weber, Stephanie; Kittaka, Chieko; Al-Saadi, Jassim A.; Scheffe, Rich; Dimmick, Fred; Tikvart, Joe

    2008-01-01

    The Clean Air Interstate Rule (CAIR) is expected to reduce transport of air pollutants (e.g. fine sulfate particles) in nonattainment areas in the Eastern United States. CAIR highlights the need for an integrated air quality observational and modeling system to understand sulfate as it moves in multiple dimensions, both spatially and temporally. Here, we demonstrate how results from an air quality model can be combined with a 3d monitoring network to provide decision makers with a tool to help quantify the impact of CAIR reductions in SO2 emissions on regional transport contributions to sulfate concentrations at surface monitors in the Baltimore, MD area, and help improve decision making for strategic implementation plans (SIPs). We sample results from the Community Multiscale Air Quality (CMAQ) model using ensemble back trajectories computed with the NASA Langley Research Center trajectory model to provide Lagrangian time series and vertical profile information, that can be compared with NASA satellite (MODIS), EPA surface, and lidar measurements. Results are used to assess the regional transport contribution to surface SO4 measurements in the Baltimore MSA, and to characterize the dominant source regions for low, medium, and high SO4 episodes.

  10. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, Katharine H.

    1990-01-01

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry.

  11. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1990-05-22

    An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  12. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1987-12-10

    An inertial impactor to be used in an air sampling device for collection of respirable size particles in ambient air which may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  13. Portable XRF analysis of occupational air filter samples from different workplaces using different samplers: final results, summary and conclusions.

    PubMed

    Harper, Martin; Pacolay, Bruce; Hintz, Patrick; Bartley, David L; Slaven, James E; Andrew, Michael E

    2007-11-01

    This paper concludes a five-year program on research into the use of a portable X-ray fluorescence (XRF) analyzer for analyzing lead in air sampling filters from different industrial environments, including mining, manufacturing and recycling. The results from four of these environments have already been reported. The results from two additional metal processes are presented here. At both of these sites, lead was a minor component of the total airborne metals and interferences from other elements were minimal. Nevertheless, only results from the three sites where lead was the most abundant metal were used in the overall calculation of method accuracy. The XRF analyzer was used to interrogate the filters, which were then subjected to acid digestion and analysis by inductively-coupled plasma optical-emission spectroscopy (ICP-OES). The filter samples were collected using different filter-holders or "samplers" where the size (diameter), depth and homogeneity of aerosol deposit varied from sampler to sampler. The aerosol collection efficiencies of the samplers were expected to differ, especially for larger particles. The distribution of particles once having entered the sampler was also expected to differ between samplers. Samplers were paired to allow the between-sampler variability to be addressed, and, in some cases, internal sampler wall deposits were evaluated and compared to the filter catch. It was found, rather surprisingly, that analysis of the filter deposits (by ICP-OES) of all the samplers gave equivalent results. It was also found that deposits on some of the sampler walls, which in some protocols are considered part of the sample, could be significant in comparison to the filter deposit. If it is concluded that wall-deposits should be analyzed, then XRF analysis of the filter can only give a minimum estimate of the concentration. Techniques for the statistical analysis of field data were also developed as part of this program and have been reported

  14. COMPARISON OF 24H AVERAGE VOC MONITORING RESULTS FOR RESIDENTIAL INDOOR AND OUTDOOR AIR USING CARBOPACK X-FILLED DIFFUSIVE SAMPLERS AND ACTIVE SAMPLING - A PILOT STUDY

    EPA Science Inventory

    Analytical results obtained by thermal desorption GC/MS for 24h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive samp...

  15. Influenza virus survival in aerosols and estimates of viable virus loss resulting from aerosolization and air-sampling.

    PubMed

    Brown, J R; Tang, J W; Pankhurst, L; Klein, N; Gant, V; Lai, K M; McCauley, J; Breuer, J

    2015-11-01

    Using a Collison nebulizer, aerosols of influenza (A/Udorn/307/72 H3N2) were generated within a controlled experimental chamber, from known starting virus concentrations. Air samples collected after variable suspension times were tested quantitatively using both plaque and polymerase chain reaction assays, to compare the proportion of viable virus against the amount of detectable viral RNA. These experiments showed that whereas influenza RNA copies were well preserved, the number of viable viruses decreased by a factor of 10(4)-10(5). This suggests that air-sampling studies for assessing infection control risks that detect only influenza RNA may greatly overestimate the amount of viable virus available to cause infection.

  16. Air sampling in the workplace. Final report

    SciTech Connect

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC`s Regulatory Guide 8.25, Revision 1, ``Air sampling in the Workplace.`` That guide addresses air sampling to meet the requirements in NRC`s regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed.

  17. Comparison of air dispersion modeling results with ambient air sampling data: A case study at Tacoma Landfill, a National Priorities List Site

    SciTech Connect

    Griffin, L.R. ); Rutherford, T.L. )

    1994-08-01

    Air dispersion modeling, ambient air sampling, and emissions testing of landfill sources have been performed to evaluate the effects of remedial activities on ambient air surrounding the Tacoma Landfill. In 1983, the Tacoma Landfill was placed on the National Priorities List (NPL) as part of the Commencement Bay/South Tacoma Channel Superfund site. Remedial activities completed, or near completion, at the 190 acre (768,903 m[sup 2]) Tacoma Landfill include a groundwater extraction system and air stripping units used to remove volatile organic compounds (VOCs) from groundwater, landfill gas extraction and flare system to control gas migration from the landfill, landfill liner and leachate collection system for an active section of the landfill, and a landfill cap that covers the inactive portions of the landfill. Dispersion modeling was performed with measured stack emission data using Industrial Source Complex (ISC) to determine the groundlevel concentrations of VOCs from the air stripper, flares, and active portion of the landfill for comparison with the measured ambient air data collected during 1992. 9 refs., 3 figs., 6 tabs.

  18. Comparison of 24 h averaged VOC monitoring results for residential indoor and outdoor air using Carbopack X-filled diffusive samplers and active sampling--a pilot study.

    PubMed

    McClenny, William A; Jacumin, Henry H; Oliver, Karen D; Daughtrey, E Hunter; Whitaker, Donald A

    2006-02-01

    Analytical results obtained by thermal desorption GC/MS for 24 h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive sampling tubes and one passivated canister. A total of eight multiple-component sampling events took place at fixed positions inside and outside three private homes. Subsequently, a known amount of sample air was transferred from the canister to an adsorbent tube for analysis by thermal desorption GC/MS. Results for the 11 most prevalent compounds--Freon 11, 1,3-butadiene, benzene, toluene, tetrachloroethene, ethylbenzene, m,p-xylene, o-xylene, 4-ethyltoluene, 1,3,5-trimethylbenzene, and p-dichlorobenzene--show that the ratio of average study values (diffusive sampling to active sampling) is 0.92 with 0.70 and 1.14 extreme ratios. Absolute percent difference for duplicate samples using diffusive sampling was <10% for the four most prevalent compounds. Agreement between the two sampling approaches indicates that the prediction of approximately constant diffusive sampling rates based on previous laboratory studies is valid under the field conditions.

  19. Extent of sample loss on the sampling device and the resulting experimental biases when collecting volatile fatty acids (VFAs) in air using sorbent tubes.

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2013-08-20

    Not all volatile organic compounds (VOCs) are suitable for sampling from air onto sorbent tubes (ST) with subsequent analysis by thermal desorption (TD) with gas chromatography (GC). Some compounds (such as C2 hydrocarbons) are too volatile for quantitative retention by sorbents at ambient temperature, while others are too reactive - either for storage stability on the tubes (post-sampling) or for thermal desorption/GC analysis. Volatile fatty acids (VFAs) are one of the compound groups that present a challenge to sorbent tube sampling. In this study, we evaluated sample losses on the inner wall surface of the sorbent tube sampler. The sorptive losses of five VFA (acetic, propionic, n-butyric, i-valeric, and n-valeric acid) were tested using two types of tubes (stainless steel and quartz), each packed with three sorbent beds arranged in order of sorbent strength from the sampling end of the tube (Tenax TA, Carbopack B, and Carbopack X). It showed significantly higher losses of VFAs in both liquid phase and vapor phase when using stainless steel tube samplers. These losses were also seen if vapor-phase fatty acids were passed through empty stainless steel tubing and increased dramatically with increasing molecular weight, e.g., losses of 33.6% (acetic acid) to 97.5% (n-valeric acid). Similar losses of VFAs were also observed from headspace sampling of cheese products. Considering that stainless steel sampling tubes are still used extensively by many researchers, their replacement with quartz tubes is recommended to reduce systematic biases in collecting VFA samples or in their calibration. PMID:23869450

  20. Methods to infer the compliance status with interval-averaged and with instantaneous occupational exposure limits from the results of longer-duration, integrated air sampling.

    PubMed

    Hunsaker, Harry A

    2016-01-01

    The duration of integrated air sampling for a substance may exceed the time frame of a substance's occupational exposure limit. Nonetheless, the compliance status of a limit may be inferred, under some circumstances, by the application of certain methods to the results of longer-duration samples. The purpose of this article is to define the inference methods and to illustrate their utility with actual and hypothetical examples. A review of articles and reports in U.S.-based Industrial Hygiene publications and databases revealed that the methods often were not but arguably should have been applied. Also revealed were inappropriate conclusions about the compliance status with exposure limits. Among the benefits of employing the inference methods is gaining information on exposures that might otherwise be overlooked. This article discusses the potential limitations of using the methods, and highlights some of the challenges of using integrated air sampling for assessing compliance with shorter-term exposure limits. PMID:26366477

  1. Air Sampling System Evaluation Template

    2000-05-09

    The ASSET1.0 software provides a template with which a user can evaluate an Air Sampling System against the latest version of ANSI N13.1 "Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities". The software uses the ANSI N13.1 PIC levels to establish basic design criteria for the existing or proposed sampling system. The software looks at such criteria as PIC level, type of radionuclide emissions, physical state ofmore » the radionuclide, nozzle entrance effects, particulate transmission effects, system and component accuracy and precision evaluations, and basic system operations to provide a detailed look at the subsystems of a monitoring and sampling system/program. A GAP evaluation can then be completed which leads to identification of design and operational flaws in the proposed systems. Corrective measures can then be limited to the GAPs.« less

  2. Air sampling with solid phase microextraction

    NASA Astrophysics Data System (ADS)

    Martos, Perry Anthony

    . With 300 seconds sampling, the formaldehyde detection limit was 2.1 ppbv, better than any other 5 minute sampling device for formaldehyde. The first-order rate constant for product formation was used to quantify formaldehyde concentrations without a calibration curve. This spot sampler was used to sample the headspace of hair gel, particle board, plant material and coffee grounds for formaldehyde, and other carbonyl compounds, with extremely promising results. The SPME sampling devices were also used for time- weighted average sampling (30 minutes to 16 hours). Finally, the four new SPME air sampling methods were field tested with side-by-side comparisons to standard air sampling methods, showing a tremendous use of SPME as an air sampler.

  3. Analytical results from ground-water sampling using a direct-push technique at the Dover National Test Site, Dover Air Force Base, Delaware, June-July 2001

    USGS Publications Warehouse

    Guertal, William R.; Stewart, Marie; Barbaro, Jeffrey R.; McHale, Timthoy J.

    2004-01-01

    A joint study by the Dover National Test Site and the U.S. Geological Survey was conducted from June 27 through July 18, 2001 to determine the spatial distribution of the gasoline oxygenate additive methyl tert-butyl ether and selected water-quality constituents in the surficial aquifer underlying the Dover National Test Site at Dover Air Force Base, Delaware. The study was conducted to support a planned enhanced bio-remediation demonstration and to assist the Dover National Test Site in identifying possible locations for future methyl tert-butyl ether remediation demonstrations. This report presents the analytical results from ground-water samples collected during the direct-push ground-water sampling study. A direct-push drill rig was used to quickly collect 115 ground-water samples over a large area at varying depths. The ground-water samples and associated quality-control samples were analyzed for volatile organic compounds and methyl tert-butyl ether by the Dover National Test Site analytical laboratory. Volatile organic compounds were above the method reporting limits in 59 of the 115 ground-water samples. The concentrations ranged from below detection limits to maximum values of 12.4 micrograms per liter of cis-1,2-dichloroethene, 1.14 micrograms per liter of trichloroethene, 2.65 micrograms per liter of tetrachloroethene, 1,070 micrograms per liter of methyl tert-butyl ether, 4.36 micrograms per liter of benzene, and 1.8 micrograms per liter of toluene. Vinyl chloride, ethylbenzene, p,m-xylene, and o-xylene were not detected in any of the samples collected during this investigation. Methyl tert-butyl ether was detected in 47 of the 115 ground-water samples. The highest methyl tert-butyl ether concentrations were found in the surficial aquifer from -4.6 to 6.4 feet mean sea level, however, methyl tert-butyl ether was detected as deep as -9.5 feet mean sea level. Increased methane concentrations and decreased dissolved oxygen concentrations were found in

  4. Evaluating Radionuclide Air Emission Stack Sampling Systems

    SciTech Connect

    Ballinger, Marcel Y.

    2002-12-16

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R&D) facilities for the U.S. Department of Energy at the Hanford Site, Washington. These facilities are subject to Clean Air Act regulations that require sampling of radionuclide air emissions from some of these facilities. A revision to an American National Standards Institute (ANSI) standard on sampling radioactive air emissions has recently been incorporated into federal and state regulations and a re-evaluation of affected facilities is being performed to determine the impact. The revised standard requires a well-mixed sampling location that must be demonstrated through tests specified in the standard. It also carries a number of maintenance requirements, including inspections and cleaning of the sampling system. Evaluations were performed in 2000 – 2002 on two PNNL facilities to determine the operational and design impacts of the new requirements. The evaluation included inspection and cleaning maintenance activities plus testing to determine if the current sampling locations meet criteria in the revised standard. Results show a wide range of complexity in inspection and cleaning activities depending on accessibility of the system, ease of removal, and potential impact on building operations (need for outages). As expected, these High Efficiency Particulate Air (HEPA)-filtered systems did not show deposition significant enough to cause concerns with blocking of the nozzle or other parts of the system. The tests for sampling system location in the revised standard also varied in complexity depending on accessibility of the sample site and use of a scale model can alleviate many issues. Previous criteria to locate sampling systems at eight duct diameters downstream and two duct diameters upstream of the nearest disturbances is no guarantee of meeting criteria in the revised standard. A computational fluid dynamics model was helpful in understanding flow and

  5. Lagrangian Sampling of 3-D Air Quality Model Results for Regional Transport Contributions to Sulfate Aerosol Concentrations at Baltimore, MD in Summer of 2004

    EPA Science Inventory

    The Lagrangian method provides estimates of the chemical and physical evolution of air arriving in the daytime boundary layer at Baltimore. Study results indicate a dominant role for regional transport contributions of those days when sulfate air pollution is highest in Baltimor...

  6. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34...

  7. Results of soil, ground-water, surface-water, and streambed-sediment sampling at Air Force Plane 85, Columbus, Ohio, 1996

    USGS Publications Warehouse

    Parnell, J.M.

    1997-01-01

    The U.S. Geological Survey (USGS), in cooperation with Aeronautical Systems Center, Environmental Management Directorate, Restoration Division, prepared the Surface- and Ground- Water Monitoring Work Plan for Air Force Plant 85 (AFP 85 or Plant), Columbus, Ohio, under the Air Force Installation Restoration Program to characterize any ground-water, surface-water, and soil contamination that may exist at AFP 85. The USGS began the study in November 1996. The Plant was divided into nine sampling areas, which included some previously investi gated study sites. The investigation activities included the collection and presentation of data taken during drilling and water-quality sampling. Data collection focused on the saturated and unsatur ated zones and surface water. Twenty-three soil borings were completed. Ten monitoring wells (six existing wells and four newly constructed monitoring wells) were selected for water-quality sam pling. Surface-water and streambed-sediment sampling locations were chosen to monitor flow onto and off of the Plant. Seven sites were sampled for both surface-water and streambed-sediment quality. This report presents data on the selected inorganic and organic constituents in soil, ground water, surface water, and streambed sediments at AFP 85. The methods of data collection and anal ysis also are included. Knowledge of the geologic and hydrologic setting could aid Aeronautical Systems Center, Environmental Management Directorate, Restoration Division, and its governing regulatory agencies in future remediation studies.

  8. Air sampling of nickel in a refinery.

    PubMed

    Harmse, Johannes L; Engelbrecht, Jacobus C

    2007-08-01

    Air monitoring was conducted in a nickel base metal refinery to determine compliance with occupational exposure limits. The hypothesis stated that levels of airborne dust may pose a risk to worker health if compared to the relevant exposure limits. Exposure limits for nickel species are set for the inhalable nickel dust fraction. Personal air samples, representative of three selected areas were collected in the workers' breathing zones, using the Institute of Occupational Medicine (IOM) samplers. Real-time personal samples were collected randomly over a two-month period in three nickel production areas. Filter papers were treated gravimetrically and were analysed for soluble and insoluble nickel through inductive coupled plasma-mass spectrometry (ICP-MS). Measured concentrations were expressed as time weighted average exposure concentrations. Results were compared to South African occupational exposure limits (OELs) and to the threshold limit values (TLVs) set by the American Conference of Governmental Industrial Hygienists (ACGIH) to determine compliance. Statistical compliance was also determined using the National Institute for Occupational Safety and Health procedure as prescribed by South Africa's Hazardous Chemical Substances Regulations in 1995. In two of the areas it was found that exposure concentrations complied with the OELs. Some exposures exceeded the OEL values and most exposures exceeded the TLV values in the other area concerned. A comprehensive health risk assessment needs to be conducted to determine the cause of non-compliance. PMID:17613095

  9. Results from Geothermal Logging, Air and Core-Water Chemistry Sampling, Air Injection Testing and Tracer Testing in the Northern Ghost Dance Fault, YUCCA Mountain, Nevada, November 1996 to August 1998

    SciTech Connect

    Lecain, G.D.; Anna, L.O.; Fahy, M.F.

    1998-08-01

    Geothermal logging, air and core-water chemistry sampling, air-injection testing, and tracer testing were done in the northern Ghost Dance Fault at Yucca Mountain, Nevada, from November 1996 to August 1998. The study was done by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy. The fault-testing drill room and test boreholes were located in the crystal-poor, middle nonlithophysal zone of the Topopah Spring Tuff, a tuff deposit of Miocene age. The drill room is located off the Yucca Mountain underground Exploratory Studies Facility at about 230 meters below ground surface. Borehole geothermal logging identified a temperature decrease of 0.1 degree Celsius near the Ghost Dance Fault. The temperature decrease could indicate movement of cooler air or water, or both, down the fault, or it may be due to drilling-induced evaporative or adiabatic cooling. In-situ pneumatic pressure monitoring indicated that barometric pressure changes were transmitted from the ground surface to depth through the Ghost Dance Fault. Values of carbon dioxide and delta carbon-13 from gas samples indicated that air from the underground drill room had penetrated the tuff, supporting the concept of a well-developed fracture system. Uncorrected carbon-14-age estimates from gas samples ranged from 2,400 to 4,500 years. Tritium levels in borehole core water indicated that the fault may have been a conduit for the transport of water from the ground surface to depth during the last 100 years.

  10. Minanre Gas Concentrators For Air Sampling

    SciTech Connect

    Dr. Seung Ho Hong

    2001-03-01

    The goal of this project was to demonstrate the feasibility of a compact, lightweight, gas-sampling device with rapid-cycle-time characteristics. The highlights of our Phase I work include: (1) Demonstration of a compact gas sampler with integrated heater. This device has an order of magnitude greater adsorption capacity and much faster heating/cooling times than commercial sorbent tubes. (2) Completion of computational fluid dynamics modeling of the gas sampler to determine airflow characteristics for various design options. These modeling efforts guided the development and testing of the Mesochannel Gas Sampler prototype. (3) Testing of the Mesochannel Gas Sampler in parallel with tests of two packed-bed samplers. These tests showed the Mesochannel Gas Sampler represents a substantial improvement compared with the packed-bed approach. Our mesochannel heat-exchanger/adsorber architecture allows very efficient use of adsorbent mass, high adsorbent loadings, and very low pressure drop, which makes possible very high air-sampling rates using a simple, low-power fan. This device is well-suited for collecting samples of trace-level contaminants. The integrated heater, which forms the adsorbent-coated mesochannel walls, allows direct heating of the adsorbent and results in very rapid desorption of the adsorbed species. We believe the Mesochannel Gas Sampler represents a promising technology for the improvement of trace-contaminant detection limits. In our Phase II proposal, we outline several improvements to the gas sampler that will further improve its performance.

  11. Direct measurements of HONO and NO2 by tunable infrared differential absorption spectroscopy; Results from two field campaigns sampling aircraft exhaust and ambient urban air

    NASA Astrophysics Data System (ADS)

    Lee, B. H.; Santoni, G.; Herndon, S. C.; Wood, E. C.; Miake-Lye, R. C.; Munger, J. W.; Wofsy, S. C.; Zahniser, M. S.; McManus, J. B.; Nelson, D. D.

    2009-12-01

    Nitrous acid (HONO) is an important source of hydroxyl radicals (OH), the main oxidizing agent in the atmosphere. However, gaseous HONO has historically proven difficult to measure accurately and to date there is no standard technique. We describe a new instrument capable of high-frequency measurements of HONO and nitrogen dioxide (NO2) mixing ratios by tunable infrared differential absorption spectrometry. Mid-infrared light from two continuous-wave mode quantum cascade lasers traverse a 210 m path through a multi-pass astigmatic cell at reduced pressures for the direct detection of HONO (1660 cm-1) and NO2 (1604 cm-1). We achieve an absorbance precision less than 3×10-6 Hz-1 in one second, which translates to detection limits (S/N=3) of 300 and 30 ppt for HONO and NO2, respectively, in one second. Both lasers and the detector are thermoelectrically cooled, facilitating long-term unattended measurements. We also report preliminary results from two field campaigns; the Alternative Aviation Fuels Experiment (AAFEX) and the Study of Houston Air Radical Precursors (SHARP). At AAFEX, HONO emission ratios relative to CO2 and NOy observed in commercial aircraft exhaust are larger than in most other combustion sources and likely to play a significant role in regional HOx chemistry. Preliminary analysis from the SHARP campaign shows good agreement in HONO and NO2 levels between various measurement techniques.

  12. EML Surface Air Sampling Program, 1990--1993 data

    SciTech Connect

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

  13. Radon discrimination for work place air samples

    SciTech Connect

    Bratvold, T.

    1994-09-27

    Gross alpha/beta measurement systems are designed solely to identify an incident particle as either an alpha or a beta and register a count accordingly. The tool of choice for radon identification, via decay daughters, is an instrument capable of identifying the energy of incident alpha particles and storing that information separately from detected alpha emissions of different energy. In simpler terms, the desired instrument is an alpha spectroscopy system. K Basins Radiological Control (KBRC) procured an EG&G ORTEC OCTETE PC alpha spectroscopy system to facilitate radon identification on work place air samples. The alpha spectrometer allows for the identification of any alpha emitting isotope based on characteristic alpha emission energies. With this new capability, KBRC will explicitly know whether or not there exists a true airborne concern. Based on historical air quality data, this new information venue will reduce the use of respirators substantially. Situations where an area remains ``on mask`` due solely to the presence of radon daughters on the grab air filter will finally be eliminated. This document serves to introduce a new method for radon daughter detection at the 183KE Health Physics Analytical Laboratory (HPAL). A new work place air sampling analysis program will be described throughout this paper. There is no new technology being introduced, nor any unproven analytical process. The program defined over the expanse of this document simply explains how K Basins Radiological Control will employ their alpha spectrometer.

  14. Efficiency of dust sampling inlets in calm air.

    PubMed

    Breslin, J A; Stein, R L

    1975-08-01

    Measurement of airborne dust concentrations usually involves drawing a sample of the dust-laden air into the measuring instrument through an inlet. Even if the surrounding air is calm, theoretical calculations predict that large particles may not be sampled accurately due to the combined effects of gravity and inertia on the particles near the sampling inlet. Tests were conducted to determine the conditions of particle size, inlet radius, and flow rare necessary for accurate dust sampling. A coal-dust aerosol was sampled simultaneously through inlets of different diameters at the same volume flow-rate and collected on filters. The dust was removed from the filters and the particles were counted and sized with a Coulter counter. Results showed that published criteria for inlet conditions for correct sampling are overly restrictive and that respirable-size particles are sampled correctly in the normal range or operation of most dust sampling instruments. PMID:1227283

  15. Concepts for Environmental Radioactive Air Sampling and Monitoring

    SciTech Connect

    Barnett, J. Matthew

    2011-11-04

    Environmental radioactive air sampling and monitoring is becoming increasingly important as regulatory agencies promulgate requirements for the measurement and quantification of radioactive contaminants. While researchers add to the growing body of knowledge in this area, events such as earthquakes and tsunamis demonstrate how nuclear systems can be compromised. The result is the need for adequate environmental monitoring to assure the public of their safety and to assist emergency workers in their response. Two forms of radioactive air monitoring include direct effluent measurements and environmental surveillance. This chapter presents basic concepts for direct effluent sampling and environmental surveillance of radioactive air emissions, including information on establishing the basis for sampling and/or monitoring, criteria for sampling media and sample analysis, reporting and compliance, and continual improvement.

  16. Air Sampling Instruments for Evaluation of Atmospheric Contaminants. Fourth Edition.

    ERIC Educational Resources Information Center

    American Conference of Governmental Industrial Hygienists, Cincinnati, OH.

    This text, a revision and extension of the first three editions, consists of papers discussing the basic considerations in sampling air for specific purposes, sampler calibration, systems components, sample collectors, and descriptions of air-sampling instruments. (BT)

  17. Presence of organophosphorus pesticide oxygen analogs in air samples

    PubMed Central

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2012-01-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (< 30 ng/m3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  18. Presence of organophosphorus pesticide oxygen analogs in air samples

    NASA Astrophysics Data System (ADS)

    Armstrong, Jenna L.; Fenske, Richard A.; Yost, Michael G.; Galvin, Kit; Tchong-French, Maria; Yu, Jianbo

    2013-02-01

    A number of recent toxicity studies have highlighted the increased potency of oxygen analogs (oxons) of several organophosphorus (OP) pesticides. These findings were a major concern after environmental oxons were identified in environmental samples from air and surfaces following agricultural spray applications in California and Washington State. This paper reports on the validity of oxygen analog measurements in air samples for the OP pesticide, chlorpyrifos. Controlled environmental and laboratory experiments were used to examine artificial formation of chlorpyrifos-oxon using OSHA Versatile Sampling (OVS) tubes as recommended by NIOSH method 5600. Additionally, we compared expected chlorpyrifos-oxon attributable to artificial transformation to observed chlorpyrifos-oxon in field samples from a 2008 Washington State Department of Health air monitoring study using non-parametric statistical methods. The amount of artificially transformed oxon was then modeled to determine the amount of oxon present in the environment. Toxicity equivalency factors (TEFs) for chlorpyrifos-oxon were used to calculate chlorpyrifos-equivalent air concentrations. The results demonstrate that the NIOSH-recommended sampling matrix (OVS tubes with XAD-2 resin) was found to artificially transform up to 30% of chlorpyrifos to chlorpyrifos-oxon, with higher percentages at lower concentrations (<30 ng m-3) typical of ambient or residential levels. Overall, the 2008 study data had significantly greater oxon than expected by artificial transformation, but the exact amount of environmental oxon in air remains difficult to quantify with the current sampling method. Failure to conduct laboratory analysis for chlorpyrifos-oxon may result in underestimation of total pesticide concentration when using XAD-2 resin matrices for occupational or residential sampling. Alternative methods that can accurately measure both OP pesticides and their oxygen analogs should be used for air sampling, and a toxicity

  19. Innovations in air sampling to detect plant pathogens

    PubMed Central

    West, JS; Kimber, RBE

    2015-01-01

    Many innovations in the development and use of air sampling devices have occurred in plant pathology since the first description of the Hirst spore trap. These include improvements in capture efficiency at relatively high air-volume collection rates, methods to enhance the ease of sample processing with downstream diagnostic methods and even full automation of sampling, diagnosis and wireless reporting of results. Other innovations have been to mount air samplers on mobile platforms such as UAVs and ground vehicles to allow sampling at different altitudes and locations in a short space of time to identify potential sources and population structure. Geographical Information Systems and the application to a network of samplers can allow a greater prediction of airborne inoculum and dispersal dynamics. This field of technology is now developing quickly as novel diagnostic methods allow increasingly rapid and accurate quantifications of airborne species and genetic traits. Sampling and interpretation of results, particularly action-thresholds, is improved by understanding components of air dispersal and dilution processes and can add greater precision in the application of crop protection products as part of integrated pest and disease management decisions. The applications of air samplers are likely to increase, with much greater adoption by growers or industry support workers to aid in crop protection decisions. The same devices are likely to improve information available for detection of allergens causing hay fever and asthma or provide valuable metadata for regional plant disease dynamics. PMID:25745191

  20. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air... detect maximum concentrations of beryllium in the ambient air. (b) All monitoring sites shall be...

  1. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air... detect maximum concentrations of beryllium in the ambient air. (b) All monitoring sites shall be...

  2. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air... detect maximum concentrations of beryllium in the ambient air. (b) All monitoring sites shall be...

  3. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air... detect maximum concentrations of beryllium in the ambient air. (b) All monitoring sites shall be...

  4. Diagnosing AIRS Sampling with CloudSat Cloud Classes

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric; Yue, Qing; Guillaume, Alexandre; Kahn, Brian

    2011-01-01

    AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.

  5. Air sampling and analysis in a rubber vulcanization area.

    PubMed

    Rappaport, S M; Fraser, D A

    1977-05-01

    Results of sampling and analysis of air in a rubber vulcanization area are described. Organic compounds were collected on activated charcoal, desorbed with carbon disulfide and analyzed by gas chromatography. Several previously identified substances were quantitated, including styrene, toluene, ethylbenzene, and several oligomers of 1,3-butadiene. Concentrations ranged from 0.007 to 1.1 ppm.

  6. Air sampling of mold spores by slit impactors: yield comparison.

    PubMed

    Pityn, Peter J; Anderson, James

    2013-01-01

    The performance of simple slit impactors for air sampling of mold contamination was compared under field conditions. Samples were collected side-by-side, outdoors in quadruplicates with Burkhard (ambient sampler) and Allergenco MK3 spore traps and with two identical Allergenco slit cassettes operated at diverse flow rates of 5 and 15 L/min, respectively. The number and types of mold spores in each sample were quantified by microscopy. Results showed all four single-stage slit impactors produced similar spore yields. Moreover, paired slit cassettes produced similar outcomes despite a three-fold difference in their sampling rate. No measurable difference in the amount or mix of mold spores per m(3)of air was detected. The implications for assessment of human exposures and interpretation of indoor/outdoor fungal burden are discussed. These findings demonstrate that slit cassettes capture most small spores, effectively and without bias, when operated at a range of flow rates including the lower flow rates used for personal sampling. Our findings indicate sampling data for mold spores correlate for different single stage impactor collection methodologies and that data quality is not deteriorated by operating conditions deviating from manufacturers' norms allowing such sampling results to be used for scientific, legal, investigative, or property insurance purposes. The same conclusion may not be applied to other particle sampling instruments and mulit-stage impactors used for ambient particulate sampling, which represent an entirely different scenario. This knowledge may help facilitate comparison between scientific studies where methodological differences exist.

  7. Results of an indoor air pollution investigation.

    PubMed

    Beller, M; Middaugh, J P

    1989-01-01

    After the opening of a new elementary school in fall 1986, several members of the school's staff noticed symptoms they attributed to the workplace. An investigation by the Occupational Safety and Health Branch (OSHA) of the Alaska Department of Labor found no major health problems and concluded that fireproofing at the school may have caused a petroleum-like odor. In fall 1987, parents reported illness in their children that they attributed to school attendance. Subsequent epidemiologic investigation found that student and staff absentee rates were not increased and were similar to other schools in the district. Testing conducted by the National Institute for Occupational Safety and Health (NIOSH) confirmed that the petroleum-like odor was due to the fireproofing. Toxicologic information and the results of air sampling confirmed that no adverse health effects would be expected from the product. By working together with NIOSH, OSHA, the school district, and a consulting mechanical engineer, deficiencies in the school's ventilation system were discovered and immediately corrected with interim engineering changes. Only by bringing multiple agencies together and openly sharing findings with concerned parents and staff were the problems at the school resolved. PMID:2596649

  8. Air Quality and Road Emission Results for Fort Stewart, Georgia

    SciTech Connect

    Kirkham, Randy R.; Driver, Crystal J.; Chamness, Mickie A.; Barfuss, Brad C.

    2004-02-02

    The Directorate of Public Works Environmental & Natural Resources Division (Fort Stewart /Hunter Army Airfield) contracted with the Pacific Northwest National Laboratory (PNNL) to monitor particulate matter (PM) concentrations on Fort Stewart, Georgia. The purpose of this investigation was to establish a PM sampling network using monitoring equipment typically used in U.S. Environmental Protection Agency (EPA) ''saturation sampling'', to determine air quality on the installation. In this initial study, the emphasis was on training-generated PM, not receptor PM loading. The majority of PM samples were 24-hr filter-based samples with sampling frequency ranging from every other day, to once every six days synchronized with the EPA 6th day national sampling schedule. Eight measurement sites were established and used to determine spatial variability in PM concentrations and evaluate whether fluctuations in PM appear to result from training activities and forest management practices on the installation. Data collected to date indicate the average installation PM2.5 concentration is lower than that of nearby urban Savannah, Georgia. At three sites near the installation perimeter, analyses to segregate PM concentrations by direction of air flow across the installation boundary indicate that air (below 80 ft) leaving the installation contains less PM2.5 than that entering the installation. This is reinforced by the observation that air near the ground is cleaner on average than the air at the top of the canopy.

  9. Stratospheric air sampling platform/sensor tradeoffs

    NASA Technical Reports Server (NTRS)

    Arno, R. D.; Page, W.

    1976-01-01

    Results of a study are described in which in-situ and remote sensing instrumentation are considered for accommodation on airborne platforms capable of reaching stratospheric altitudes. The instrumentation measures trace species of importance to present concerns regarding stratospheric pollution and possible ozone depletion. The platforms examined were the U-2, modified U-2, balloon, rocket, F-15 flown in a zoom-climb maneuver, YF-12, and remotely piloted vehicle (RPV). The sensors and performance characteristics of the platforms are described and special problems of sensor-platform integration are discussed. A typical latitudinal sampling mission is utilized to describe platform logistics problems and how the platforms might perform such missions.

  10. Statistical Literacy and Sample Survey Results

    ERIC Educational Resources Information Center

    McAlevey, Lynn; Sullivan, Charles

    2010-01-01

    Sample surveys are widely used in the social sciences and business. The news media almost daily quote from them, yet they are widely misused. Using students with prior managerial experience embarking on an MBA course, we show that common sample survey results are misunderstood even by those managers who have previously done a statistics course. In…

  11. Monitoring air sampling in operating theatres: can particle counting replace microbiological sampling?

    PubMed

    Landrin, A; Bissery, A; Kac, G

    2005-09-01

    Microbiological contamination of air in the operating room is generally considered to be a risk factor for surgical site infections in clean surgery. Evaluation of the quality of air in operating theatres can be performed routinely by microbiological sampling and particle counting, but the relationship between these two methods has rarely been evaluated. The aim of this study was to determine whether particle counting could be predictive of microbiological contamination of air in operating rooms. Over a three-month period, air microbiological sampling and particle counting were performed simultaneously in four empty operating rooms belonging to two surgical theatres equipped with conventional ventilation via high-efficiency particulate air filters. Correlation between the two methods was measured with Spearman's correlation coefficient. The ability of particle counting to discriminate between microbiological counting values higher and lower than 5 colony-forming units (CFU)/m3 was evaluated using receiver-operating characteristic (ROC) analysis. Microbiological counting ranged from 0 to 38CFU/m3, while the particle counts ranged from 0 to 46 262/m3. Methods of microbiological and particle counting did not correlate (Spearman correlation coefficient=0.06, P=0.6). Using the ROC curve, no particle count value could be predictive of a microbiological count higher than 5CFU/m3. The results of the current study suggest that there is no reason to replace microbiological sampling with particle counting for routine evaluation of microbiological contamination in conventionally ventilated operating theatres.

  12. Sampling Interplanetary Dust Particles from Antarctic Air

    NASA Astrophysics Data System (ADS)

    Taylor, S.; Lever, J. H.; Alexander, C. M. O'D.; Brownlee, D. E.; Messenger, S.; Littler, L. R.; Stroud, R. M.; Wozniakiewicz, P.; Clement, S.

    2016-08-01

    We are undertaking a NASA and NSF supported project to filter large volumes of clean Antarctic air to collect a broad range of cosmic dust, including CP-IDPs, rare ultra-carbonaceous particles and particles derived from specific meteor streams.

  13. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

    SciTech Connect

    Maxwell, S.; Noyes, G.; Culligan, B.

    2010-02-03

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

  14. A continuous sampling air-ICP for metals emission monitoring

    SciTech Connect

    Baldwin, D.P.; Zamzow, D.S.; Eckels, D.E.; Miller, G.P.

    1999-09-19

    An air-inductively coupled plasma (air-ICP) system has been developed for continuous sampling and monitoring of metals as a continuous emission monitor (CEM). The plasma is contained in a metal enclosure to allow reduced-pressure operation. The enclosure and plasma are operated at a pressure slightly less than atmospheric using a Roots blower, so that sample gas is continuously drawn into the plasma. A Teflon sampling chamber, equipped with a sampling pump, is connected to the stack that is to be monitored to isokinetically sample gas from the exhaust line and introduce the sample into the air-ICP. Optical emission from metals in the sampled gas stream is detected and monitored using an acousto-optic tunable filter (AOTF)--echelle spectrometer system. A description of the continuous sampling air-ICP system is given, along with some preliminary laboratory data for continuous monitoring of metals.

  15. Statistical literacy and sample survey results

    NASA Astrophysics Data System (ADS)

    McAlevey, Lynn; Sullivan, Charles

    2010-10-01

    Sample surveys are widely used in the social sciences and business. The news media almost daily quote from them, yet they are widely misused. Using students with prior managerial experience embarking on an MBA course, we show that common sample survey results are misunderstood even by those managers who have previously done a statistics course. In general, they fare no better than managers who have never studied statistics. There are implications for teaching, especially in business schools, as well as for consulting.

  16. Venturi Air-Jet Vacuum Ejector For Sampling Air

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Burney, L. Garland; Wade, Larry O.

    1990-01-01

    Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

  17. Sample Results from Routine Salt Batch 7 Samples

    SciTech Connect

    Peters, T.

    2015-05-13

    Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 7B have been analyzed for 238Pu, 90Sr, 137Cs, Inductively Coupled Plasma Emission Spectroscopy (ICPES), and Ion Chromatography Anions (IC-A). The results from the current microbatch samples are similar to those from earlier samples from this and previous macrobatches. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal, and there is a distinct positive trend in Cs removal, due to the use of the Next Generation Solvent (NGS). The Savannah River National Laboratory (SRNL) notes that historically, most measured Concentration Factor (CF) values during salt processing have been in the 12-14 range. However, recent processing gives CF values closer to 11. This observation does not indicate that the solvent performance is suffering, as the Decontamination Factor (DF) has still maintained consistently high values. Nevertheless, SRNL will continue to monitor for indications of process upsets. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior.

  18. In-mask aerosol sampling for powered air purifying respirators

    SciTech Connect

    Liu, B.Y.U.; Sega, K.; Rubow, K.L.; Lenhart, S.W.; Myers, W.R.

    1984-04-01

    A system for sampling aerosols in the facepiece of a powered air purifying respirator has been described. The system consists of a sampling inlet mounted on the respiratory facepiece, a filter cassette and a personal sampling pump. The theoretical and practical considerations leading to the design of the sampling inlet have been discussed and experimental data presented showing the efficiency of the inlet as a function of particle size and sampling flow rate. The in-mask sampling system has been designed for powered air purifying respirators.

  19. Sampling and analysis of terpenes in air. An interlaboratory comparison

    NASA Astrophysics Data System (ADS)

    Larsen, Bo; Bomboi-Mingarro, Teresa; Brancaleoni, Enzo; Calogirou, Aggelos; Cecinato, Angelo; Coeur, Cecile; Chatzinestis, Ioannis; Duane, Matthew; Frattoni, Massimiliano; Fugit, Jean-Luc; Hansen, Ute; Jacob, Veronique; Mimikos, Nikolaos; Hoffmann, Thorsten; Owen, Susan; Perez-Pastor, Rosa; Reichmann, Andreas; Seufert, Gunther; Staudt, Michael; Steinbrecher, Rainer

    An interlaboratory comparison on the sampling and analysis of terpenes in air was held within the framework of the BEMA (Biogenic Emissions in the Mediterranean Area) project in May 1995. Samples were drawn and analysed by 10 European laboratories from a dynamic artificial air generator in which five terpenes were present at low ng ℓ -1 levels and ozone varied between 8 and 125 ppbv. Significant improvements over previous inter-comparison exercises in the quality of results were observed. At the ozone mixing ratio of 8 ppbv a good agreement among laboratories was obtained for all test compounds with mean values close to the target concentration. At higher mixing ratios, ozone reduced terpene recoveries and decreased the precision of the measurements due to ozonolysis during sampling. For β-pinene this effect was negligible but for the more reactive compounds significant losses were observed in some laboratories ( cis-β-ocimene = trans-β-ocimene > linalool > d-limonene). The detrimental effect of ozone was significantly lower for the laboratories which removed ozone prior to sampling by scrubbers. Parallel sampling was carried out with a standardised sampler and each individual laboratory's own device. A good agreement between the two sets of results was obtained, clearly showing that the majority of laboratories used efficient sampling systems. Two different standard solutions were analysed by each laboratory. Only in a few cases did interference in the GC separation cause problems for the quantification of the terpenes (nonanal/linalool). However, making up of standards for the calibration of the analytical equipment (GC-MS or GC-FID) was pointed out as a source of error in some laboratories.

  20. Workplace air monitoring and sampling practices at DOE facilities

    SciTech Connect

    Swinth, K.L.; Kenoyer, J.L.; Selby, J.M.; Vallario, E.J.; Burphy, B.L.

    1986-03-01

    Current air monitoring and sampling practices at DOE facilities were surveyed as a part of an air monitoring upgrade task. A comprehensive questionnaire was developed and distributed to DOE contractors through the DOE field offices. Twenty-six facilities returned a completed questionnaire. Questionnaire replies indicate diversity in air sampling and monitoring practices among DOE facilities. The difference among the facilities exist in monitoring and sampling instrumentation, procedures, calibration, analytical methods, detection levels, and action levels. Many of these differences could be attributed to different operational needs.

  1. Sample Results from MCU Solids Outage

    SciTech Connect

    Peters, T.; Washington, A.; Oji, L.; Coleman, C.; Poirier, M.

    2014-09-22

    Savannah River National Laboratory (SRNL) has received several solid and liquid samples from MCU in an effort to understand and recover from the system outage starting on April 6, 2014. SRNL concludes that the presence of solids in the Salt Solution Feed Tank (SSFT) is the likely root cause for the outage, based upon the following discoveries: A solids sample from the extraction contactor #1 proved to be mostly sodium oxalate; A solids sample from the scrub contactor#1 proved to be mostly sodium oxalate; A solids sample from the Salt Solution Feed Tank (SSFT) proved to be mostly sodium oxalate; An archived sample from Tank 49H taken last year was shown to contain a fine precipitate of sodium oxalate; A solids sample from ; A liquid sample from the SSFT was shown to have elevated levels of oxalate anion compared to the expected concentration in the feed. Visual inspection of the SSFT indicated the presence of precipitated or transferred solids, which were likely also in the Salt Solution Receipt Tank (SSRT). The presence of the solids coupled with agitation performed to maintain feed temperature resulted in oxalate solids migration through the MCU system and caused hydraulic issues that resulted in unplanned phase carryover from the extraction into the scrub, and ultimately the strip contactors. Not only did this carryover result in the Strip Effluent (SE) being pushed out of waste acceptance specification, but it resulted in the deposition of solids into several of the contactors. At the same time, extensive deposits of aluminosilicates were found in the drain tube in the extraction contactor #1. However it is not known at this time how the aluminosilicate solids are related to the oxalate solids. The solids were successfully cleaned out of the MCU system. However, future consideration must be given to the exclusion of oxalate solids into the MCU system. There were 53 recommendations for improving operations recently identified. Some additional considerations or

  2. Results of the air emission research study

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Air quality was monitored in beef mono-slope barns. The objectives of the study were 1) to gather baseline data for the levels of gas emissions and particulate matter from beef mono-slope facilities, 2) evaluate the effect of two different manure handling systems on air quality, and 3) provide infor...

  3. Ammonia Results Review for Retained Gas Sampling

    SciTech Connect

    Mahoney, Lenna A.

    2000-09-20

    This report was prepared as part of a task supporting the deployment of the retained gas sampler (RGS) system in Flammable Gas Watch List Tanks. The emphasis of this report is on presenting supplemental information about the ammonia measurements resulting from retained gas sampling of Tanks 241-AW-101, A-101, AN-105, AN-104, AN-103, U-103, S-106, BY-101, BY-109, SX-106, AX-101, S-102, S-111, U-109, and SY-101. This information provides a better understanding of the accuracy of past RGS ammonia measurements, which will assist in determining flammable and toxicological hazards.

  4. A simple novel device for air sampling by electrokinetic capture

    SciTech Connect

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the

  5. A simple novel device for air sampling by electrokinetic capture

    DOE PAGES

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A.

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of

  6. Direct analysis of air filter samples for alpha emitting isotopes

    SciTech Connect

    Mohagheghi, A.H.; Ghanbari, F.; Ebara, S.B.; Enghauser, M.E.; Bakhtiar, S.N.

    1997-04-01

    The traditional method for determination of alpha emitting isotopes on air filters has been to process the samples by radiochemical methods. However, this method is too slow for cases of incidents involving radioactive materials where the determination of personnel received dose is urgent. A method is developed to directly analyze the air filters taken from personal and area air monitors. The site knowledge is used in combination with alpha spectral information to identify isotopes. A mathematical function is developed to estimate the activity for each isotope. The strengths and weaknesses of the method are discussed.

  7. A STRINGENT COMPARISON OF SAMPLING AND ANALYSIS METHODS FOR VOCS IN AMBIENT AIR

    EPA Science Inventory

    A carefully designed study was conducted during the summer of 1998 to simultaneously collect samples of ambient air by canisters and compare the analysis results to direct sorbent preconcentration results taken at the time of sample collection. A total of 32 1-h sample sets we...

  8. Rapid on-site air sampling with a needle extraction device for evaluating the indoor air environment in school facilities.

    PubMed

    Inoue, Mitsuru; Mizuguchi, Ayako; Ueta, Ikuo; Takahashi, Kazuya; Saito, Yoshihiro

    2013-01-01

    A rapid on-site air sampling technique was developed with a miniaturized needle-type sample preparation device for a systematic evaluation of the indoor air environments in school facilities. With the in-needle extraction device packed with a polymer particle of divinylbenzene and activated carbon particles, various types of volatile organic compounds (VOCs) were successfully extracted. For evaluating the indoor air qualities in school facilities, air samples in renovated rooms using organic solvent as a thinner of the paint were analyzed along with measurements of several VOCs in indoor air samples taken in newly built primary schools mainly using low-VOCs materials. After periodical renovation/maintenance, the time-variation profile of typical VOCs found in the school facilities has also been monitored. From the results, it could be observed that the VOCs in most of the rooms in these primary schools were at a quite low level; however, a relatively higher concentration of VOCs was found in some specially designed rooms, such as music rooms. In addition, some non-regulated compounds, including benzyl alcohol and branched alkanes, were detected in these primary schools. The results showed a good applicability of the needle device to indoor air analysis in schools, suggesting a wide range of future employment of the needle device, especially for indoor air analysis in other types of facilities and rooms including hospitals and hotels. PMID:23665624

  9. Sampling of air streams and incorporation of samples in the Microtox{trademark} toxicity testing system

    SciTech Connect

    Kleinheinz, G.T.; St. John, W.P.

    1997-10-01

    A study was conducted to develop a rapid and reliable method for the collection and incorporation of biofiltration air samples containing volatile organic compounds (VOCs) into the Microtox toxicity testing system. To date, no method exists for this type of assay. A constant stream of VOCs was generated by air stripping compounds from a complex mixture of petroleum hydrocarbons (PHCs). Samples were collected on coconut charcoal ORBO tubes and the VOCs extracted with methylene chloride. The compounds extracted were then solvent exchanged into dimethyl sulfoxide (DMSO) under gaseous nitrogen. The resulting DMSO extract was directly incorporated into the Microtox toxicity testing system. In order to determine the efficiency of the solvent exchange, the VOCs in the DMSO extract were then extracted into hexane and subsequently analyzed using gas chromatography (GC) with a flame ionization detector (FID). It was determined that all but the most volatile VOCs could be effectively transferred from the ORBO tubes to DMSO for Microtox testing. Potential trace amounts of residual methylene chloride in the DMSO extracts showed no adverse effects in the Microtox system when compared to control samples.

  10. Bias in air sampling techniques used to measure inhalation exposure.

    PubMed

    Cohen, B S; Harley, N H; Lippmann, M

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and "mini hi-volume" samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. We conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  11. Bias in air sampling techniques used to measure inhalation exposure

    SciTech Connect

    Cohen, B.S.; Harley, N.H.; Lippmann, M.

    1984-03-01

    Factors have been evaluated which contribute to the lack of agreement between inhalation exposure estimates obtained by time-weighted averaging of samples taken with mini hi-volume samplers, and those measured by time integrating, low-volume, lapel mounted, personal monitors. Measurements made with real-time aerosol monitors on workers at a Be-Cu production furnace show that part of the discrepancy results from variability of the aerosol concentration within the breathing zone. Field studies of sampler inlet bias, the influences of the electrostatic fields around polystyrene filter holders, and resuspension of dust from work clothing, were done in three areas of a Be plant. No significant differences were found in Be air concentrations measured simultaneously by open and closed face cassettes, and mini hi-volume samplers mounted on a test stand. No significant influence on Be collection was detected between either positively or negatively charged monitors and charge neutralized control monitors. The effect of contaminated work clothing on dust collection by lapel mounted monitors is most important. Beryllium release from the fabrics affected air concentrations measured by fabric mounted monitors more than it affected concentrations measured by monitors positioned above the fabrics. The latter were placed 16 cm from the vertically mounted fabrics, to simulate the position of the nose or mouth. The authors conclude that dust resuspended from work clothing is the major source of the observed discrepancy between exposures estimated from lapel mounted samplers and time-weighted averages.

  12. Continuous air monitor correlation to fixed air sample data at Los Alamos National Laboratory

    SciTech Connect

    Whicker, J.J.

    1993-05-01

    Continuous air monitoring instruments (CAMS) deployed in laboratories in the TA-55 plutonium facility at Los Alamos National Laboratory (LANL) alarmed less than 33 percent of the time when fixed air sample measurements in the same laboratory showed integrated concentrations exceeding 500 DAC-hrs. The purpose of this study was to explore effects of non-instrument variables on alarm sensitivities for properly working CAMS. Non-instrument variables include air flow patterns, particle size of released material, and the energy of the release. Dilution Factors (DFs) for 21 airborne releases in various rooms and of different magnitudes were calculated and compared. The median DF for releases where the CAM alarmed was 13.1 while the median DF for releases where the CAM did not alarm was 179. Particle sizes ranged considerably with many particles larger than 10 {mu}m. The cause of the release was found to be important in predicting if a CAM would alarm with releases from bagouts resulting in the greatest percentage of CAM alarms. The results of this study suggest that a two-component strategy for CAM placement at LANL be utilized. The first component would require CAMs at exhaust points in the rooms to provide for reliable detection for random release locations. The second component would require placing CAMs at locations where releases have historically been seen. Finally, improvements in CAM instrumentation is needed.

  13. Summary of gamma spectrometry on local air samples from 1985--1995

    SciTech Connect

    Winn, W.G.

    1997-04-02

    This report summarizes the 1985--1995 results of low-level HPGe gamma spectrometry analysis of high-volume air samples collected at the Aiken Airport, which is about 25 miles north of SRS. The author began analyzing these samples with new calibrations using the newly developed GRABGAM code in 1985. The air sample collections were terminated in 1995, as the facilities at the Aiken Airport were no longer available. Air sample measurements prior to 1985 were conducted with a different analysis system (and by others prior to 1984), and the data were not readily available. The report serves to closeout this phase of local NTS air sample studies, while documenting the capabilities and accomplishments. Hopefully, the information will guide other applications for this technology, both locally and elsewhere.

  14. Comparison of stationary and personal air sampling with an air dispersion model for children's ambient exposure to manganese.

    PubMed

    Fulk, Florence; Haynes, Erin N; Hilbert, Timothy J; Brown, David; Petersen, Dan; Reponen, Tiina

    2016-09-01

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to assess exposure for children enrolled in the Communities Actively Researching Exposure Study in Marietta, OH. Ambient air Mn concentration values were modeled using US Environmental Protection Agency's Air Dispersion Model AERMOD based on emissions from the ferromanganese refinery located in Marietta. Modeled Mn concentrations were compared with Mn concentrations from a nearby stationary air monitor. The Index of Agreement for modeled versus monitored data was 0.34 (48 h levels) and 0.79 (monthly levels). Fractional bias was 0.026 for 48 h levels and -0.019 for monthly levels. The ratio of modeled ambient air Mn to measured ambient air Mn at the annual time scale was 0.94. Modeled values were also time matched to personal air samples for 19 children. The modeled values explained a greater degree of variability in personal exposures compared with time-weighted distance from the emission source. Based on these results modeled Mn concentrations provided a suitable approach for assessing airborne Mn exposure in this cohort. PMID:27168393

  15. Comparison of stationary and personal air sampling with an air dispersion model for children's ambient exposure to manganese.

    PubMed

    Fulk, Florence; Haynes, Erin N; Hilbert, Timothy J; Brown, David; Petersen, Dan; Reponen, Tiina

    2016-09-01

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to assess exposure for children enrolled in the Communities Actively Researching Exposure Study in Marietta, OH. Ambient air Mn concentration values were modeled using US Environmental Protection Agency's Air Dispersion Model AERMOD based on emissions from the ferromanganese refinery located in Marietta. Modeled Mn concentrations were compared with Mn concentrations from a nearby stationary air monitor. The Index of Agreement for modeled versus monitored data was 0.34 (48 h levels) and 0.79 (monthly levels). Fractional bias was 0.026 for 48 h levels and -0.019 for monthly levels. The ratio of modeled ambient air Mn to measured ambient air Mn at the annual time scale was 0.94. Modeled values were also time matched to personal air samples for 19 children. The modeled values explained a greater degree of variability in personal exposures compared with time-weighted distance from the emission source. Based on these results modeled Mn concentrations provided a suitable approach for assessing airborne Mn exposure in this cohort.

  16. Cellulomonas aerilata sp. nov., isolated from an air sample.

    PubMed

    Lee, Chang-Muk; Weon, Hang-Yeon; Hong, Seung-Beom; Jeon, Young-Ah; Schumann, Peter; Kroppenstedt, Reiner M; Kwon, Soon-Wo; Stackebrandt, Erko

    2008-12-01

    A Gram-positive, aerobic, motile, coccoid or short rod-shaped bacterium, 5420S-23(T), was isolated from an air sample collected in the Republic of Korea. According to phylogenetic analysis based on 16S rRNA gene sequences, strain 5420S-23(T) revealed 97.5, 97.3, 97.3 and 97.2 % similarity, respectively, to Cellulomonas biazotea DSM 20112(T), Cellulomonas cellasea DSM 20118(T), Cellulomonas fimi DSM 20113(T) and Cellulomonas chitinilytica X.bu-b(T). The peptidoglycan type of strain 5420S-23(T) was A4beta, containing l-ornithine-d-glutamic acid. The cell-wall sugars were galactose, glucose and xylose. The major fatty acids were anteiso-C(15 : 0) (49.7 %) and C(16 : 0) (20.0 %). The major menaquinone was MK-9(H(4)) and major polar lipids were diphosphatidylglycerol and phosphatidylglycerol. The DNA G+C content was 74 mol%. The results of DNA-DNA hybridization with strains of closely related Cellulomonas species, in combination with chemotaxonomic and physiological data, demonstrated that isolate 5420S-23(T) represents a novel Cellulomonas species, for which the name Cellulomonas aerilata sp. nov. is proposed, with strain 5420S-23(T) (=KACC 20692(T) =DSM 18649(T)) as the type strain.

  17. Dispersion modeling of selected PAHs in urban air: A new approach combining dispersion model with GIS and passive air sampling

    NASA Astrophysics Data System (ADS)

    Sáňka, Ondřej; Melymuk, Lisa; Čupr, Pavel; Dvorská, Alice; Klánová, Jana

    2014-10-01

    This study introduces a new combined air concentration measurement and modeling approach that we propose can be useful in medium and long term air quality assessment. A dispersion study was carried out for four high molecular weight polycyclic aromatic hydrocarbons (PAHs) in an urban area with industrial, traffic and domestic heating sources. A geographic information system (GIS) was used both for processing of input data as well as visualization of the modeling results. The outcomes of the dispersion model were compared to the results of passive air sampling (PAS). Despite discrepancies between measured and modeled concentrations, an approach combining the two techniques is promising for future air quality assessment. Differences between measured and modeled concentrations, in particular when measured values exceed the modeled concentrations, are indicative of undocumented, sporadic pollutant sources. Thus, these differences can also be useful for assessing and refining emission inventories.

  18. Ambient Air Sampling During Quantum-dot Spray Deposition

    SciTech Connect

    Jankovic, John Timothy; Hollenbeck, Scott M

    2010-01-01

    Ambient air sampling for nano-size particle emissions was performed during spot spray coating operations with a Sono-Tek Exactacoat Benchtop system (ECB). The ECB consisted of the application equipment contained within an exhaust enclosure. The enclosure contained numerous small access openings, including an exhaust hook-up. Door access comprised most of the width and height of the front. The door itself was of the swing-out type. Two types of nanomaterials, Cadmium selenide (Cd-Se) quantum-dots (QDs) and Gold (Au) QDs, nominally 3.3 and 5 nm in diameter respectively, were applied during the evaluation. Median spray drop size was in the 20 to 60 micrometer size range.1 Surface coating tests were of short duration, on the order of one-half second per spray and ten spray applications between door openings. The enclosure was ventilated by connection to a high efficiency particulate aerosol (HEPA) filtered house exhaust system. The exhaust rate was nominally 80 ft3 per minute producing about 5 air changes per minute. Real time air monitoring with a scanning mobility particle size analyzer (SMPS ) with a size detection limit of 7 nm indicated a significant increase in the ambient air concentration upon early door opening. A handheld condensation particle counter (CPC) with a lower size limit of 10 nm did not record changes in the ambient background. This increase in the ambient was not observed when door opening was delayed for 2 minutes (~10 air changes). The ventilated enclosure controlled emissions except for cases of rapid door opening before the overspray could be removed by the exhaust. A time delay sufficient to provide 10 enclosure air changes (a concentration reduction of more than 99.99 %) before door opening prevented the release of aerosol particles in any size.2 Scanning-transmission electron microscopy (STEM) and atomic force microscopy (AFM) demonstrated the presence of agglomerates in the surfaces of the spray applied deposition. A filtered air sample of

  19. Passive air sampling of gaseous elemental mercury: a critical review

    NASA Astrophysics Data System (ADS)

    McLagan, David S.; Mazur, Maxwell E. E.; Mitchell, Carl P. J.; Wania, Frank

    2016-03-01

    Because gaseous elemental mercury (GEM) is distributed globally through the atmosphere, reliable means of measuring its concentrations in air are important. Passive air samplers (PASs), designed to be cheap, simple to operate, and to work without electricity, could provide an alternative to established active sampling techniques in applications such as (1) long-term monitoring of atmospheric GEM levels in remote regions and in developing countries, (2) atmospheric mercury source identification and characterization through finely resolved spatial mapping, and (3) the recording of personal exposure to GEM. An effective GEM PAS requires a tightly constrained sampling rate, a large and stable uptake capacity, and a sensitive analytical technique. None of the GEM PASs developed to date achieve levels of accuracy and precision sufficient for the reliable determination of background concentrations over extended deployments. This is due to (1) sampling rates that vary due to meteorological factors and manufacturing inconsistencies, and/or (2) an often low, irreproducible and/or unstable uptake capacity of the employed sorbents. While we identify shortcomings of existing GEM PAS, we also reveal potential routes to overcome those difficulties. Activated carbon and nanostructured metal surfaces hold promise as effective sorbents. Sampler designs incorporating diffusive barriers should be able to notably reduce the influence of wind on sampling rates.

  20. Results from the International Halocarbons in Air Comparison Experiment (IHALACE)

    NASA Astrophysics Data System (ADS)

    Hall, B. D.; Engel, A.; Mühle, J.; Elkins, J. W.; Artuso, F.; Atlas, E.; Aydin, M.; Blake, D.; Brunke, E.-G.; Chiavarini, S.; Fraser, P. J.; Happell, J.; Krummel, P. B.; Levin, I.; Loewenstein, M.; Maione, M.; Montzka, S. A.; O'Doherty, S.; Reimann, S.; Rhoderick, G.; Saltzman, E. S.; Scheel, H. E.; Steele, L. P.; Vollmer, M. K.; Weiss, R. F.; Worthy, D.; Yokouchi, Y.

    2014-02-01

    The International Halocarbons in Air Comparison Experiment (IHALACE) was conducted to document relationships between calibration scales among various laboratories that measure atmospheric greenhouse and ozone depleting gases. This study included trace gases such as chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs), and hydrofluorocarbons (HFCs), as well as nitrous oxide, methane, sulfur hexafluoride, very short-lived halocompounds, and carbonyl sulfide. Many of these gases are present in the unpolluted atmosphere at pmol mol-1 (parts per trillion) or nmol mol-1 (parts per billion) levels. Six stainless steel cylinders containing natural and modified natural air samples were circulated among 19 laboratories. Results from this experiment reveal relatively good agreement (within a few percent) among commonly used calibration scales. Scale relationships for some gases, such as CFC-12 and CCl4, were found to be consistent with those derived from estimates of global mean mole fractions, while others, such as halon-1211 and CH3Br, revealed discrepancies. The transfer of calibration scales among laboratories was problematic in many cases, meaning that measurements tied to a particular scale may not, in fact, be compatible. Large scale transfer errors were observed for CH3CCl3 (10-100%) and CCl4 (2-30%), while much smaller scale transfer errors (< 1%) were observed for halon-1211, HCFC-22, and HCFC-142b. These results reveal substantial improvements in calibration over previous comparisons. However, there is room for improvement in communication and coordination of calibration activities with respect to the measurement of halogenated and related trace gases.

  1. Relative Humidity and its Effect on Sampling and Analysis of Agricultural Odorants in Air

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Source and ambient air sampling techniques used in agricultural air quality studies are seldom validated for the variability in the air matrix (temperature, dust levels, and relative humidity). In particular, relative humidity (RH) affects both field sampling and analysis of air samples. The objec...

  2. Air exchange effectiveness in office buildings: Measurement techniques and results

    SciTech Connect

    Fisk, W.J.; Faulkner, D.

    1992-07-01

    We define two air exchange effectiveness parameters which indicate the extent of short circuiting, mixing, or displacement air flow in an entire building, the air diffusion effectiveness which indicates the air flow pattern locally, and the normalized local age of air. After describing two tracer gas procedures for measuring these parameters, we discuss assumptions inherent in the data analysis that are often violated in large office buildings. To obtain valuable data, careful selection of buildings for measurements and assessments to determine if operating conditions are reasonably consistent with the assumptions are necessary. Multiple factors, in addition to the air flow pattern in the occupied space, can affect measurement results, consequently, the interpretation of measurements is not straightforward. We summarize the results of measurements in several office buildings and in a research laboratory. Almost all measurements indicate that the extent of both short circuiting and displacement flow is small. A moderate amount of short circuiting is evident from a few measurements in rooms with heated supply air. Ages of air and their reciprocals (local ventilation rates) often vary substantially between rooms, probably because of room-to-room variation in the rate of air supply. For future research, we suggest assessments of measurement accuracy, development of measurement approaches that may be practically applied for a broader range of buildings, and a greater focus on pollutant removal efficiencies.

  3. Evaluation of Urban Air Quality By Passive Sampling Technique

    NASA Astrophysics Data System (ADS)

    Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.

    Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many

  4. Survey of volatile organic compounds found in indoor and outdoor air samples from Japan.

    PubMed

    Tanaka-Kagawa, Toshiko; Uchiyama, Shigehisa; Matsushima, Erika; Sasaki, Akira; Kobayashi, Hiroshi; Kobayashi, Hiromi; Yagi, Masahiro; Tsuno, Masahiko; Arao, Masa; Ikemoto, Kazumi; Yamasaki, Makoto; Nakashima, Ayako; Shimizu, Yuri; Otsubo, Yasufumi; Ando, Masanori; Jinno, Hideto; Tokunaga, Hiroshi

    2005-01-01

    Indoor air quality is currently a growing concern, mainly due to the incidence of sick building syndrome and building related illness. To better understand indoor air quality in Japan, both indoor and outdoor air samples were collected from 50 residences in Iwate, Yamanashi, Shiga, Hyogo, Kochi and Fukuoka Prefectures. More than 100 volatile organic compounds (VOCs) were analyzed by thermal desorption-gas chromatography/mass spectrometry method. The most abundant class of compounds present in the indoor air samples were identified (i.e. alkanes, alkylbenzenes and terpenes). For 30% of the indoor air samples, the sum of each VOC exceeded the current provisional guideline value for total VOC (TVOC, 400 microg/m3). The major component of these samples included linear and branched-chain alkanes (possibly derived from fossil fuels), 1,4-dichlorobenzene (a moth repellent), alpha-pinene (emission from woody building materials) and limonene (probably derived from aroma products). As an unexpected result, one residence was polluted with an extremely high concentration of 1,1,1,2-tetrafluoroethane (720 microg/m3), suggesting accidental leakage from a household appliance such as a refrigerator. The results presented in this paper are important in establishing the Japanese target compound list for TVOC analysis, as well as defining the current status of indoor air quality in Japan.

  5. Performance of underfloor air distribution: Results of a field study

    SciTech Connect

    Fisk, William; Faulkner, David; Sullivan, Douglas

    2004-09-02

    Underfloor air distribution (UFAD) is a new method of supplying heated or cooled air throughout a building. Reported advantages of UFAD include easy relocation of air supply diffusers, energy savings, and improved indoor air quality (IAQ). We measured several aspects of the performance of an UFAD system installed in a medium-size office building. The measured air change effectiveness was very close to unity, which is comparable to that measured in buildings with typical overhead air distribution. The pollutant removal efficiency for carbon dioxide was 13 percent higher than expected in a space with well-mixed air, suggesting a 13 percent reduction in exposures to occupant generated pollutants. The increase in indoor air temperatures with height above the floor was only 1 to 2 C (2-4 F). This amount of thermal stratification could reduce the sensible energy requirements for cooling of outdoor air by approximately 10 percent. The occupants level of satisfaction with thermal conditions w as well above average and this high satisfaction rating could possibly be due, in all or part, to the use of a UFAD system. The results of this study provide some evidence of moderate energy and IAQ-related benefits of UFAD. Before general conclusions are drawn, the benefits need to be confirmed in other studies.

  6. Identification of ambient air sampling and analysis methods for the 189 Title III air toxics

    SciTech Connect

    Mukund, R.; Kelly, T.J.; Gordon, S.M.; Hays, M.J.

    1994-12-31

    The state of development of ambient air measurement methods for the 189 Hazardous Air Pollution (HAPs) in Title 3 of the Clean Air Act Amendments was surveyed. Measurement methods for the HAPs were identified by reviews of established methods, and by literature searches for pertinent research techniques. Methods were segregated by their degree of development into Applicable, Likely, and Potential methods. This survey identified a total of 183 methods, applicable at varying degrees to ambient air measurements of one or more HAPs. As a basis for classifying the HAPs and evaluating the applicability of measurement methods, a survey of a variety of chemical and physical properties of the HAPs was also conducted. The results of both the methods and properties surveys were tabulated for each of the 189 HAP. The current state of development of ambient measurement methods for the 189 HAPs was then assessed from the results of the survey, and recommendations for method development initiatives were developed.

  7. Microbial counts and particulate matter levels in roadside air samples under skytrain stations, Bangkok, Thailand.

    PubMed

    Luksamijarulkul, Pipat; Kongtip, Pornpimol

    2010-05-01

    In conditions with heavy traffic and crowds of people on roadside areas under skytrain stations in Bangkok, the natural air ventilation may be insufficient and air quality may be poor. A study of 350 air samples collected from the roadside, under skytrain stations in Bangkok, was carried out to assess microbial counts (210 air samples) and particulate matter (PM10) levels (140 samples). The results reveal the mean +/- standard deviation bacterial counts and fungal counts were 406.8 +/- 302.7 cfu/m3 and 128.9 +/- 89.7 cfu/m3, respectively. The PM10 level was 186.1 +/- 188.1 microg/m3. When compared to recommended levels, 4.8% of air samples (10/210 samples) had bacterial counts more than recommended levels (> 1,000 cfu/ m3) and 27.1% (38/140 samples) had PM10 levels more than recommended levels (> 120 microg/m3). These may affect human health, especially of street venders who spend most of their working time in these areas. PMID:20578558

  8. Microbial counts and particulate matter levels in roadside air samples under skytrain stations, Bangkok, Thailand.

    PubMed

    Luksamijarulkul, Pipat; Kongtip, Pornpimol

    2010-05-01

    In conditions with heavy traffic and crowds of people on roadside areas under skytrain stations in Bangkok, the natural air ventilation may be insufficient and air quality may be poor. A study of 350 air samples collected from the roadside, under skytrain stations in Bangkok, was carried out to assess microbial counts (210 air samples) and particulate matter (PM10) levels (140 samples). The results reveal the mean +/- standard deviation bacterial counts and fungal counts were 406.8 +/- 302.7 cfu/m3 and 128.9 +/- 89.7 cfu/m3, respectively. The PM10 level was 186.1 +/- 188.1 microg/m3. When compared to recommended levels, 4.8% of air samples (10/210 samples) had bacterial counts more than recommended levels (> 1,000 cfu/ m3) and 27.1% (38/140 samples) had PM10 levels more than recommended levels (> 120 microg/m3). These may affect human health, especially of street venders who spend most of their working time in these areas.

  9. Joint air pollution sampling program in twin cities on the U.S.-Mexico border.

    PubMed

    Dávila, G H

    1976-01-01

    Ciudad Juárez (Chihuahua) and El Paso (Texas), two cities on the U.S.-Mexico border, form a single environmental system in which the same natural resources, especially air and water, are shared. It also constitutes a single metropolitan area which is characterized by high rates of pipulation growth, economic development, and urban expansion, all these factors mitigating against air quality. Early in 1972 the health authorities in El Paso and Ciudad Juárez initiated a joint air pollution sampling program with assistance from the Pan American Health Organization. The nearby city of Las Cruces (New Mexico) was later included in the program as well. Activities are carried out in accordance with a document entitled "Bases of Cooperation." The guiding criteria of the program are: functional simplicity, operational economy, and complementarity with other sampling programs conducted by the participating services. An Air Pollution Control Subcommittee is responsible for execution coordination of the program. Three studies are currently underway to determine levels of dust pollution in the air. A fourth study is aimed at measuring sulfur dioxide levels through the use of sulfation plates. The results collected reveal concentrations of particulates in the ambient air levels higher than the U.S. Federal primary standards. The program should be expanded to include the study of other pollutants and a joint inventory of emissions. In this way criteria on air quality may be established and joint plans of action and strategies drawn up for the control of air pollution in this important area.

  10. Determination of radiocarbon in stratospheric CO2, obtained through AirCore sampling.

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Chen, Huilin; Been, Henk A.; Kivi, Rigel; Meijer, Harro A. J.

    2016-04-01

    The concentration of Greenhouse Gases (GHG), with carbon dioxide as the most prominent example, has been and still is increasing, predominantly due to emissions from fossil fuel combustion. CO2 is also the most important component of the global carbon cycle. Among other tracers, radiocarbon (Carbon-14) is a unique and an important atmospheric tracer used in the understanding of the global carbon cycle. Radiocarbon is a naturally occurring isotope (radioactive, t 1/2 = 5730 ± 40 years) of carbon produced through the interaction of thermalized neutrons and nitrogen in the upper atmosphere. Generally, for performing atmospheric radiocarbon measurements in the higher atmosphere, large samples (few liters of air) were collected using aircrafts and balloons. However, collecting stratospheric samples on a regular basis for radiocarbon analysis is extremely expensive. Here we describe the determination of radiocarbon concentrations in stratospheric CO2, collected using AirCore sampling. AirCore is an innovative sampling technique for obtaining vertical atmospheric profiles and, in Europe, is done on a regular basis at Sodankylä, Finland for CO2, CH4 and CO. The stratospheric parts of two such AirCore profiles were used in this study as a proof-of-principle. CO2 from the stratospheric air samples were extracted and converted to elemental carbon, which were then measured at the Accelerator Mass Spectrometric (AMS) facility of the Centre for Isotope Research (CIO) at the University of Groningen. The stratospheric part of the AirCore profile was divided into six sections, each contained approximately 10 μg C. A detailed description of the extraction, graphitization, AMS analysis and the derivation of the stratospheric radiocarbon profile will be the main focus. Through our results, we will show that AirCore is a viable sampling method for performing high-precision radiocarbon measurements of stratospheric CO2 with reasonably good spatial resolution on a regular basis

  11. Radiocarbon analysis of stratospheric CO2 retrieved from AirCore sampling

    NASA Astrophysics Data System (ADS)

    Paul, Dipayan; Chen, Huilin; Been, Henk A.; Kivi, Rigel; Meijer, Harro A. J.

    2016-10-01

    calibration and contamination correction purposes. The results show that the Δ14CO2 values from tropopause up to about 19(±1) km for the sample collected on 15 July was 18 ± 6 ‰ (samples 1-4), very similar to the current tropospheric value. On the other hand, Δ14CO2 values from tropopause up to about 18(±1) km for the sample collected on 16 July (samples 1-4) showed a large gradient from -62 to 21 ‰. The next sample in the profile, corresponding to about 18(±1)-22(±2) km (one sample from each profile), shows slight enrichment of 80 ± 20 ‰. The last section from both profiles, containing air from the upper stratosphere, was contaminated with pre-fill air.

  12. Measurement results obtained from air quality monitoring system

    SciTech Connect

    Turzanski, P.K.; Beres, R.

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracow area could be more intelligible.

  13. Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

    NASA Technical Reports Server (NTRS)

    Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.

    1974-01-01

    The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

  14. STATISTICAL ANALYSIS OF TANK 18F FLOOR SAMPLE RESULTS

    SciTech Connect

    Harris, S.

    2010-09-02

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 18F as per the statistical sampling plan developed by Shine [1]. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL [2]. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results [3] to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL{sub 95%}) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 18F. The uncertainty is quantified in this report by an upper 95% confidence limit (UCL{sub 95%}) on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL{sub 95%} was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  15. STATISTICAL ANALYSIS OF TANK 19F FLOOR SAMPLE RESULTS

    SciTech Connect

    Harris, S.

    2010-09-02

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 19F as per the statistical sampling plan developed by Harris and Shine. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL95%) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current scrape sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 19F. The uncertainty is quantified in this report by an UCL95% on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL95% was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  16. Field evaluation of endotoxin air sampling assay methods.

    PubMed

    Thorne, P S; Reynolds, S J; Milton, D K; Bloebaum, P D; Zhang, X; Whitten, P; Burmeister, L F

    1997-11-01

    This study tested the importance of filter media, extraction and assay protocol, and bioaerosol source on the determination of endotoxin under field conditions in swine and poultry confinement buildings. Multiple simultaneous air samples were collected using glass fiber (GF) and polycarbonate (PC) filters, and these were assayed using two methods in two separate laboratories: an endpoint chromogenic Limulus amebocyte lysate (LAL) assay (QCL) performed in water and a kinetic chromogenic LAL assay (KQCL) performed in buffer with resistant-parallel line estimation analysis (KLARE). In addition, two aqueous filter extraction methods were compared in the QCL assay: 120 min extraction at 22 degrees C with vigorous shaking and 30 min extraction at 68 degrees C with gentle rocking. These extraction methods yielded endotoxin activities that were not significantly different and were very highly correlated. Reproducibility of endotoxin determinations from duplicate air sampling filters was very high (Cronbach alpha all > 0.94). When analyzed by the QCL method GF filters yielded significantly higher endotoxin activity than PC filters. QCL and KLARE methods gave similar estimates for endotoxin activity from PC filters; however, GF filters analyzed by the QCL method yielded significantly higher endotoxin activity estimates, suggesting enhancement of the QCL assay or inhibition of the KLARE asay with GF filters. Correlation between QCL-GF and QCL-PC was high (r = 0.98) while that between KLARE-GF and KLARE-PC was moderate (r = 0.68). Analysis of variance demonstrated that assay methodology, filter-type, barn-type, and interactions between assay and filter-type and between assay and barn-type were important factors influencing endotoxin exposure assessment.

  17. Modeling air quality over China: Results from the Panda project

    NASA Astrophysics Data System (ADS)

    Katinka Petersen, Anna; Bouarar, Idir; Brasseur, Guy; Granier, Claire; Xie, Ying; Wang, Lili; Wang, Xuemei

    2015-04-01

    China faces strong air pollution problems related to rapid economic development in the past decade and increasing demand for energy. Air quality monitoring stations often report high levels of particle matter and ozone all over the country. Knowing its long-term health impacts, air pollution became then a pressing problem not only in China but also in other Asian countries. The PANDA project is a result of cooperation between scientists from Europe and China who joined their efforts for a better understanding of the processes controlling air pollution in China, improve methods for monitoring air quality and elaborate indicators in support of European and Chinese policies. A modeling system of air pollution is being setup within the PANDA project and include advanced global (MACC, EMEP) and regional (WRF-Chem, EMEP) meteorological and chemical models to analyze and monitor air quality in China. The poster describes the accomplishments obtained within the first year of the project. Model simulations for January and July 2010 are evaluated with satellite measurements (SCIAMACHY NO2 and MOPITT CO) and in-situ data (O3, CO, NOx, PM10 and PM2.5) observed at several surface stations in China. Using the WRF-Chem model, we investigate the sensitivity of the model performance to emissions (MACCity, HTAPv2), horizontal resolution (60km, 20km) and choice of initial and boundary conditions.

  18. Novel sample preparation technique with needle-type micro-extraction device for volatile organic compounds in indoor air samples.

    PubMed

    Ueta, Ikuo; Mizuguchi, Ayako; Fujimura, Koji; Kawakubo, Susumu; Saito, Yoshihiro

    2012-10-01

    A novel needle-type sample preparation device was developed for the effective preconcentration of volatile organic compounds (VOCs) in indoor air before gas chromatography-mass spectrometry (GC-MS) analysis. To develop a device for extracting a wide range of VOCs typically found in indoor air, several types of particulate sorbents were tested as the extraction medium in the needle-type extraction device. To determine the content of these VOCs, air samples were collected for 30min with the packed sorbent(s) in the extraction needle, and the extracted VOCs were thermally desorbed in a GC injection port by the direct insertion of the needle. A double-bed sorbent consisting of a needle packed with divinylbenzene and activated carbon particles exhibited excellent extraction and desorption performance and adequate extraction capacity for all the investigated VOCs. The results also clearly demonstrated that the proposed sample preparation method is a more rapid, simpler extraction/desorption technique than traditional sample preparation methods. PMID:22975183

  19. Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2008-04-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

  20. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2009-01-23

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

  1. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  2. Passive Samplers for Investigations of Air Quality: Method Description, Implementation, and Comparison to Alternative Sampling Methods

    EPA Science Inventory

    This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...

  3. An Autosampler and Field Sample Carrier for Maximizing Throughput Using an Open-Air, Surface Sampling Ion Source for MS

    EPA Science Inventory

    A recently developed, commercially available, open-air, surface sampling ion source for mass spectrometers provides individual analyses in several seconds. To realize its full throughput potential, an autosampler and field sample carrier were designed and built. The autosampler ...

  4. Plant responses to reduced air pressure: advanced techniques and results

    NASA Astrophysics Data System (ADS)

    Daunicht, H.-J.; Brinkjans, H. J.

    1996-01-01

    Knowledge on air pressure impacts on plant processes and growth is essential for understanding responses to altitude and for comprehending the way of action of aerial gasses in general, and is of potential importance for life support systems in space. Our research on reduced air pressure was extended by help of a new set-up comprising two constantly ventilated chambers (283 L each), allowing pressure gradients of +/- 100 kPa. They provide favourable general growth conditions while maintaining all those factors constant or at desired levels which modify the action of air pressure, e.g. water vapour pressure deficit and air mass flow over the plants. Besides plant growth parameters, transpiration and CO_2 gas exchange are determined continuously. Results are presented on young tomato plants grown hydroponically, which had been treated with various combinations of air pressure (400 - 700 - 1000 hPa), CO_2 concentration and wind intensity for seven days. At the lowest pressure transpiration was enhanced considerably, and the plants became sturdier. On the other hand growth was retarded to a certain extent, attributable to secondary air pressure effects. Therefore, even greater limitations of plant productivity are expected after more extended periods of low pressure treatment.

  5. Participant evaluation results for two indoor air quality studies

    SciTech Connect

    Hawthorne, A.R.; Dudney, C.S.; Cohen, M.A.; Spengler, J.D.

    1987-01-01

    After two surveys for indoor air pollutants (radon and other chemicals) the homeowners were surveyed for their reactions. The results of these participant evaluation surveys, assuming that the participants that responded to the survey were representative, indicate that homeowners will accept a significant level of monitoring activity as part of an indoor air quality field study. Those participants completing surveys overwhelmingly enjoyed being in the studies and would do it again. We believe that the emphasis placed on positive homeowner interactions and efforts made to inform participants throughout our studies were positive factors in this result. There was no substantial differences noted in the responses between the 70-house study, which included a homeowner compensation payment of $100, and the 300-house study, which did not include a compensation payment. These results provide encouragement to conduct future complex, multipollutant indoor air quality studies when they are scientifically sound and cost effective.

  6. Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

    NASA Technical Reports Server (NTRS)

    Condon, E. P.; Vedder, J. F.

    1984-01-01

    Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

  7. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    PubMed

    Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  8. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  9. Modeling and Qualification of a Modified Emission Unit for Radioactive Air Emissions Stack Sampling Compliance.

    PubMed

    Barnett, J Matthew; Yu, Xiao-Ying; Recknagle, Kurtis P; Glissmeyer, John A

    2016-11-01

    A planned laboratory space and exhaust system modification to the Pacific Northwest National Laboratory Material Science and Technology Building indicated that a new evaluation of the mixing at the air sampling system location would be required for compliance to ANSI/HPS N13.1-2011. The modified exhaust system would add a third fan, thereby increasing the overall exhaust rate out the stack, thus voiding the previous mixing study. Prior to modifying the radioactive air emissions exhaust system, a three-dimensional computational fluid dynamics computer model was used to evaluate the mixing at the sampling system location. Modeling of the original three-fan system indicated that not all mixing criteria could be met. A second modeling effort was conducted with the addition of an air blender downstream of the confluence of the three fans, which then showed satisfactory mixing results. The final installation included an air blender, and the exhaust system underwent full-scale tests to verify velocity, cyclonic flow, gas, and particulate uniformity. The modeling results and those of the full-scale tests show agreement between each of the evaluated criteria. The use of a computational fluid dynamics code was an effective aid in the design process and allowed the sampling system to remain in its original location while still meeting the requirements for sampling at a well mixed location. PMID:27682902

  10. Professional judgment and the interpretation of viable mold air sampling data.

    PubMed

    Johnson, David; Thompson, David; Clinkenbeard, Rodney; Redus, Jason

    2008-10-01

    Although mold air sampling is technically straightforward, interpreting the results to decide if there is an indoor source is not. Applying formal statistical tests to mold sampling data is an error-prone practice due to the extreme data variability. With neither established exposure limits nor useful statistical techniques, indoor air quality investigators often must rely on their professional judgment, but the lack of a consensus "decision strategy" incorporating explicit decision criteria requires professionals to establish their own personal set of criteria when interpreting air sampling data. This study examined the level of agreement among indoor air quality practitioners in their evaluation of airborne mold sampling data and explored differences in inter-evaluator assessments. Eighteen investigators independently judged 30 sets of viable mold air sampling results to indicate: "definite indoor mold source," "likely indoor mold source," "not enough information to decide," "likely no indoor mold source," or "definitely no indoor mold source." Kappa coefficient analysis indicated weak inter-observer reliability, and comparison of evaluator mean scores showed clear inter-evaluator differences in their overall scoring patterns. The responses were modeled on indicator "traits" of the data sets using a generalized, linear mixed model approach and showed several traits to be associated with respondents' ratings, but they also demonstrated distinct and divergent inter-evaluator response patterns. Conclusions were that there was only weak overall agreement in evaluation of the mold sampling data, that particular traits of the data were associated with the conclusions reached, and that there were substantial inter-evaluator differences that were likely due to differences in the personal decision criteria employed by the individual evaluators. The overall conclusion was that there is a need for additional work to rigorously explore the constellation of decision criteria

  11. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  12. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    SciTech Connect

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear ES

  13. Air-sampled Filter Analysis for Endotoxins and DNA Content.

    PubMed

    Lang-Yona, Naama; Mazar, Yinon; Pardo, Michal; Rudich, Yinon

    2016-01-01

    Outdoor aerosol research commonly uses particulate matter sampled on filters. This procedure enables various characterizations of the collected particles to be performed in parallel. The purpose of the method presented here is to obtain a highly accurate and reliable analysis of the endotoxin and DNA content of bio-aerosols extracted from filters. The extraction of high molecular weight organic molecules, such as lipopolysaccharides, from sampled filters involves shaking the sample in a pyrogen-free water-based medium. The subsequent analysis is based on an enzymatic reaction that can be detected using a turbidimetric measurement. As a result of the high organic content on the sampled filters, the extraction of DNA from the samples is performed using a commercial DNA extraction kit that was originally designed for soils and modified to improve the DNA yield. The detection and quantification of specific microbial species using quantitative polymerase chain reaction (q-PCR) analysis are described and compared with other available methods. PMID:27023725

  14. Air sampling filtration media: Collection efficiency for respirable size-selective sampling

    PubMed Central

    Soo, Jhy-Charm; Monaghan, Keenan; Lee, Taekhee; Kashon, Mike; Harper, Martin

    2016-01-01

    The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min−1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes. PMID:26834310

  15. The effect of sampling technique on PCR-based bacteriological results of bovine milk samples.

    PubMed

    Hiitiö, Heidi; Simojoki, Heli; Kalmus, Piret; Holopainen, Jani; Pyörälä, Satu; Taponen, Suvi

    2016-08-01

    The aim of the study was to evaluate the effect of sampling technique on the microbiological results of bovine milk samples using multiplex real-time PCR. Comparison was made between a technique where the milk sample was taken directly from the udder cistern of the udder quarter using a needle and vacuum tube and conventional sampling. The effect of different cycle threshold (Ct) cutoff limits on the results was also tested to estimate the amount of amplified DNA in the samples. A total of 113 quarters from 53 cows were tested pairwise using both techniques, and each sample was studied with real-time PCR. Sampling from the udder cistern reduced the number of species per sample compared with conventional sampling. In conventional samples, the number of positive Staphylococcus spp. results was over twice that of samples taken with the needle technique, indicating that most of the Staphylococcus spp. originated from the teat or environmental sources. The Ct values also showed that Staphylococcus spp. were present in most samples only in low numbers. Routine use of multiplex real-time PCR in mastitis diagnostics could benefit from critical evaluation of positive Staphylococcus spp. results with Ct values between 34.0 and 37.0. Our results emphasize the importance of a careful aseptic milk sampling technique and a microbiologically positive result for a milk sample should not be automatically interpreted as an intramammary infection or mastitis.

  16. Permeation of atmospheric gases through polymer O-rings used in flasks for air sampling

    NASA Astrophysics Data System (ADS)

    Sturm, P.; Leuenberger, M.; Sirignano, C.; Neubert, R. E. M.; Meijer, H. A. J.; Langenfelds, R.; Brand, W. A.; Tohjima, Y.

    2004-02-01

    Permeation of various gases through elastomeric O-ring seals can have important effects on the integrity of atmospheric air samples collected in flasks and measured some time later. Depending on the materials and geometry of flasks and valves and on partial pressure differences between sample and surrounding air, the concentrations of different components of air can be significantly altered during storage. The influence of permeation is discussed for O2/N2, Ar/N2, CO2, δ13C in CO2, and water vapor. Results of sample storage tests for various flask and valve types and different storage conditions are presented and are compared with theoretical calculations. Effects of permeation can be reduced by maintaining short storage times and small partial pressure differences and by using a new valve design that buffers exchange of gases with surrounding air or by using less permeable materials (such as Kel-F) as sealing material. General awareness of possible permeation effects helps to achieve more reliable measurements of atmospheric composition with flask sampling techniques.

  17. BIASES IN CASTNET FILTER PACK RESULTS ASSOCIATED WITH SAMPLING PROTOCOL

    EPA Science Inventory

    In the current study, single filter weekly (w) results are compared with weekly results aggregated from day and night (dn) weekly samples. Comparisons of the two sampling protocols for all major constituents (SO42-, NO3-, NH4+, HNO3, and SO2) show median bias (MB) of < 5 nmol m-3...

  18. Report on sampling and analysis of exhaust air at the 221-T and 2706-T buildings

    SciTech Connect

    Stauffer, M.

    1997-09-22

    This report presents analytical results from exhaust air samples collected at stacks 221-T and 2706-T of the T-Plant. The samples were collected with SUMMA canisters over a 24 hour interval and were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data suggest that the buildings had generally low concentrations of volatile organic compounds (< 40 ppbv). However, samples from building 2706-T did have significant amounts of non-target higher-boiling hydrocarbons, probably from a petroleum destination fraction.

  19. Breakthrough of 1,3-dichloropropene and chloropicrin from 600 mg XAD-4 air sampling tubes

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Accurately measuring air concentrations of agricultural fumigants is important for the regulation of air quality. Understanding the conditions under which sorbent tubes can effectively retain such fumigants during sampling is critical in mitigating chemical breakthrough from the tubes and facilitati...

  20. Spirosoma aerophilum sp. nov., isolated from an air sample.

    PubMed

    Kim, Soo-Jin; Ahn, Jae-Hyung; Weon, Hang-Yeon; Hong, Seung-Beom; Seok, Soon-Ja; Kim, Jeong-Seon; Kwon, Soon-Wo

    2016-06-01

    A rod-shaped, yellow, Gram-stain-negative, non-flagellated, aerobic bacterium, designated 5516J-17T, was isolated from an air sample collected from Jeju Island, Republic of Korea. It grew in the temperature range of 10-37 °C (optimum 28-30 °C), pH 6.0-11.0 (optimum, pH 7.0) and 0-1 % NaCl (w/v). Phylogenetic trees generated using 16S rRNA gene sequences revealed that strain 5516J-17T belongs to the genus Spirosoma, showing 96.9 % sequence similarity to the most closely related species, Spirosoma linguale DSM 74T. The cellular fatty acids comprised large amounts (>10 % of total fatty acids) of summed feature 3 (C16:1ω7c and/or C16:1ω6c) and C16:1ω5c, and moderate amounts (5-10 % of total fatty acids) of iso-C17:0 3-OH, iso-C15:0 and C16:0. The DNA G+C content was 55.7 mol % and MK-7 was the predominant isoprenoid quinone. Polar lipids were phosphatidylethanolamine, two unknown aminophospholipids, one unknown aminolipid and one unknown lipid. On the basis of this phenotypic and polyphasic taxonomy study, it is suggested that strain 5516J-17T represents a novel species within the genus Spirosoma, with the proposed name Spirosoma aerophilum. The type strain is 5516J-17T (= KACC 17323T = DSM 28388T = JCM 19950T). PMID:27031168

  1. Terrabacter aeriphilus sp. nov., isolated from an air sample.

    PubMed

    Weon, Hang-Yeon; Son, Jung-A; Yoo, Seung-Hee; Kim, Byung-Yong; Kwon, Soon-Wo; Schumann, Peter; Kroppenstedt, Reiner; Stackebrandt, Erko

    2010-05-01

    A novel actinomycete, designated strain 5414T-18(T), was isolated from an air sample collected from the Taean region, Korea. The strain contained oxidase and grew in the presence of 7 % NaCl. A neighbour-joining tree constructed on the basis of the 16S rRNA gene sequence showed that strain 5414T-18(T) is a member of the genus Terrabacter, sharing 97.8-98.3 % 16S rRNA gene sequence similarities to type strains of species of the genus Terrabacter (98.3 % sequence similarity with Terrabacter lapilli LR-26(T)). It contained peptidoglycan containing ll-diaminopimelic acid of A3gamma type, with three glycine residues as the interpeptide bridge. Whole-cell sugars were glucose, mannose and ribose. Mycolic acids were absent. The predominant menaquinone was MK-8(H(4)). The major fatty acids (>7 % of total fatty acids) were iso-C(15 : 0), iso-C(16 : 0), C(17 : 1)omega8c and iso-C(14 : 0). The major polar lipids were phosphatidylethanolamine, diphosphatidylglycerol, phosphatidylinositol and an unidentified phosphoglycolipid. The DNA G+C content of the type strain was 73 mol%. Strain 5414T-18(T) exhibited DNA-DNA relatedness levels of 44, 43, 39, 34 and 34 % to the type strains of Terrabacter lapilli, Terrabacter aerolatus, Terrabacter terrae, Terrabacter tumescens and Terracoccus luteus, respectively. These findings suggest that strain 5414T-18(T) represents a novel species within the genus Terrabacter. The name Terrabacter aeriphilus sp. nov. is proposed for this novel species, with the type strain 5414T-18(T) (=KACC 20693(T)=DSM 18563(T)).

  2. Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

    NASA Technical Reports Server (NTRS)

    Blake, Donald R.

    2001-01-01

    University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

  3. ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements

    NASA Technical Reports Server (NTRS)

    Honne, A.; Schumann-Olsen, H.; Kaspersen, K.; Limero, T.; Macatangay, A.; Mosebach, H.; Kampf, D.; Mudgett, P. D.; James, J. T.; Tan, G.; Supper, W.

    2009-01-01

    ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.

  4. Chemical reactivities of ambient air samples in three Southern California communities

    PubMed Central

    Eiguren-Fernandez, Arantza; Di Stefano, Emma; Schmitz, Debra A.; Guarieiro, Aline Lefol Nani; Salinas, Erika M.; Nasser, Elina; Froines, John R.; Cho, Arthur K.

    2015-01-01

    The potential adverse health effects of PM2.5 and vapor samples from three communities that neighbor railyards, Commerce (CM), Long Beach (LB), and San Bernardino (SB), were assessed by determination of chemical reactivities attributed to the induction of oxidative stress by air pollutants. The assays used were dithiothreitol (DTT) and dihydrobenzoic acid (DHBA) based procedures for prooxidant content and a glyceraldehyde-3-phosphate dehydrogenase (GAPDH) assay for electrophiles. Prooxidants and electrophiles have been proposed as the reactive chemical species responsible for the induction of oxidative stress by air pollution mixtures. The PM2.5 samples from CM and LB sites showed seasonal differences in reactivities with higher levels in the winter whereas the SB sample differences were reversed. The reactivities in the vapor samples were all very similar, except for the summer SB samples, which contained higher levels of both prooxidants and electrophiles. The results suggest the observed reactivities reflect general geographical differences rather than direct effects of the railyards. Distributional differences in reactivities were also observed with PM2.5 fractions containing most of the prooxidants (74–81%) and the vapor phase most of the electrophiles (82–96%). The high levels of the vapor phase electrophiles and their potential for adverse biological effects point out the importance of the vapor phase in assessing the potential health effects of ambient air. PMID:25947123

  5. Microbial air-sampling equipment, part 1: meeting United States pharmacopeia chapter 797 standards.

    PubMed

    Kastango, Eric S

    2008-01-01

    The most recent changes to Chapter 797 of the United States Pharmcopeia-National Formulary initiated an intense controversy about the frequency of cleanroom air sampling that is required to prevent the contamination of sterile preparations. For compounders who must purchase an air sampler to use in the cleanroom, choices abound. Included in this article are a review of United States Pharmacopeia-National Formulary requirements that pertain to air sampling, a discussion of how recent revision to Chapter 797 affect air sampling and patient safety, and, for easy reference, a table that features specifications for various models of microbial air samplers.

  6. Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis

    SciTech Connect

    MULKEY, C.H.

    1999-07-06

    This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through the DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.

  7. Review of Various Air Sampling Methods for Solvent Vapors.

    ERIC Educational Resources Information Center

    Maykoski, R. T.

    Vapors of trichloroethylene, toluene, methyl ethyl ketone, and butyl cellosolve in air were collected using Scotchpac and Tedlar bags, glass prescription bottles, and charcoal adsorption tubes. Efficiencies of collection are reported. (Author/RH)

  8. [Analysis of polycyclic aromatic hydrocarbons in air samples by gas chromatography-triple quadrupole mass spectrometry].

    PubMed

    Zhao, Bo; Li, Yuqing; Zhang, Sukun; Han, Jinglei; Xu, Zhencheng; Fang, Jiande

    2014-09-01

    A method of gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-MS/MS) has been optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in air samples. In the analysis step, isotope dilution was introduced to the quantification of PAHs. The GC-MS/MS method was applied to the analysis of the real air samples around a big petrochemical power plant in South China. The results were compared with those obtained by gas chromatography coupled to mass spectrometry (GC-MS). The results showed that better selectivity and sensitivity were obtained by GC-MS/MS. It was found that the external standard of deuterated-PAHs and internal standard of hexamethyl benzene were disturbed seriously with GC-MS, and the problems were both solved effectively by GC-MS/MS. Therefore more accurate quantification results of PAHs were obtained with GC-MS/MS. For the analysis of real samples, the RSDs of relative response factors ranged from 2.60% to 15.6% in standard curves; the recoveries of deuterated-PAHs ranged from 55.2% to 82.3%; the recoveries of spiked samples ranged from 98.9% to 111%; the RSDs of parallel specimens ranged from 6.50% to 18.4%; the concentrations of field blank samples ranged from not detected to 44.3 pg/m3; and the concentrations of library blank samples ranged from not detected to 36.5 pg/m3. The study indicated that the application of GC-MS/MS on the analysis of PAHs in air samples was recommended. PMID:25752088

  9. Analysis of a workplace air particulate sample by synchronous luminescence and room-temperature phosphorescence

    SciTech Connect

    Vo-Dinh, T.; Gammage, R.B.; Martinez, P.R.

    1981-02-01

    An analysis of a XAD-2 resin extract of a particulate air sample collected at an industrial environment was conducted by use of two simple spectroscopic methods performed at ambient temperature, the synchronous luminescence and room-temperature phosphorescence techniques. Results of the analysis of 13 polynuclear aromatic compounds including anthracene, benzo(a)pyrene, benzo(e)pyrene, 2,3-benzofluorene, chrysene, 1,2,5,6-dibenzanthracene, dibenzthiophene, fluoranthene, fluorene, phenanthrene, perylene, pyrene, and tetracene were reported.

  10. Indoor/ambient residential air toxics results in rural western Montana.

    PubMed

    Ward, Tony J; Underberg, Heidi; Jones, David; Hamilton, Raymond F; Adams, Earle

    2009-06-01

    Indoor and ambient concentrations of 21 volatile organic compounds (including 14 hazardous air pollutants) were measured in the homes of nearly 80 western Montana (Missoula) high school students as part of the 'Air Toxics Under the Big Sky' program during the 2004/2005 and 2005/2006 school years. Target analytes were measured using low flow air sampling pumps and sorbent tubes, with analysis of the exposed samples by thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS). The results reported here present the findings of the first indoor/ambient air toxics monitoring program conducted in a semi-rural valley location located in the Northern Rocky Mountain/Western Montana region. Of all of the air toxics quantified in this study, toluene was found to be the most abundant compound in both the indoor and ambient environments during each of the two school years. Indoor log-transformed mean concentrations were found to be higher when compared with ambient log-transformed mean concentrations at P < 0.001 for the majority of the compounds, supporting the results of previous studies conducted in urban areas. For the air toxics consistently measured throughout this program, concentrations were approximately six times higher inside the student's homes compared to those simultaneously measured directly outside their homes. For the majority of the compounds, there were no significant correlations between indoor and ambient concentrations.

  11. Field evaluation of sampling and analysis for organic pollutants in indoor air. Project summary

    SciTech Connect

    Chuang, J.C.; Mack, G.A.; Stockrahm, J.W.; Hannan, S.W.; Bridges, C.

    1988-09-01

    The objectives of the study were to determine the feasibility of the use of newly developed indoor air samplers in residential indoor air sampling and to evaluate methodology for characterization of the concentrations of polynuclear aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in residential air.

  12. Statistical Analysis of Tank 5 Floor Sample Results

    SciTech Connect

    Shine, E. P.

    2013-01-31

    Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide1, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements

  13. Statistical Analysis Of Tank 5 Floor Sample Results

    SciTech Connect

    Shine, E. P.

    2012-08-01

    Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements

  14. STATISTICAL ANALYSIS OF TANK 5 FLOOR SAMPLE RESULTS

    SciTech Connect

    Shine, E.

    2012-03-14

    Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, radionuclide, inorganic, and anion concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their

  15. Qualification Tests for the Air Sampling System at the 296-Z-7 Stack

    SciTech Connect

    Glissmeyer, John A; Maughan, A David

    2001-10-15

    This report documents tests performed to verify that the monitoring system for the 296-Z-7 ventilation stack meets the applicable regulatory criteria regarding the placement of the air sampling probe, sample transport, and stack flow measurement accuracy.

  16. Modelled air pollution levels versus EC air quality legislation - results from high resolution simulation.

    PubMed

    Chervenkov, Hristo

    2013-12-01

    An appropriate method for evaluating the air quality of a certain area is to contrast the actual air pollution levels to the critical ones, prescribed in the legislative standards. The application of numerical simulation models for assessing the real air quality status is allowed by the legislation of the European Community (EC). This approach is preferable, especially when the area of interest is relatively big and/or the network of measurement stations is sparse, and the available observational data are scarce, respectively. Such method is very efficient for similar assessment studies due to continuous spatio-temporal coverage of the obtained results. In the study the values of the concentration of the harmful substances sulphur dioxide, (SO2), nitrogen dioxide (NO2), particulate matter - coarse (PM10) and fine (PM2.5) fraction, ozone (O3), carbon monoxide (CO) and ammonia (NH3) in the surface layer obtained from modelling simulations with resolution 10 km on hourly bases are taken to calculate the necessary statistical quantities which are used for comparison with the corresponding critical levels, prescribed in the EC directives. For part of them (PM2.5, CO and NH3) this is done for first time with such resolution. The computational grid covers Bulgaria entirely and some surrounding territories and the calculations are made for every year in the period 1991-2000. The averaged over the whole time slice results can be treated as representative for the air quality situation of the last decade of the former century.

  17. Stationary source sampling report: Volatile organic compounds testing, 300-M area air stripper exhaust stack

    SciTech Connect

    Not Available

    1985-11-25

    An air stripping column was used in the 300-M area to remove volatile organic compounds from contaminated groundwater. Tests were performed October 29, 1985, at the air stripper exhaust stack to measure the emissions of tetrachloroethylene, trichloroethylene, and 1,1,1-trichloroethane for compliance purposes. Three absorbent sampling train (AST) runs (yielding duplicate samples for each run) and three velocity traverses were performed at the air stripper exhaust stack. Ambient air sampling was not performed as scheduled because of inclement weather conditions.

  18. A method for sampling halothane and enflurane present in trace amounts in ambient air.

    PubMed

    Burm, A G; Spierdijk, J

    1979-03-01

    A method for the sampling of small amounts of halothane and enflurane in ambient air is described. Sampling is performed by drawing air through a sampling tube packed with Porapak Q, which absorbs the anesthetic agent. The amount absorbed is determined by gas chromatography after thermal desorption. This method can be used for "spot" or personal sampling or for determining mean whole-room concentrations over relatively long periods (several hours).

  19. Microbial air-sampling equipment, part 2: experiences of compounding pharmacists.

    PubMed

    Mixon, Bill; Cabaleiro, Joe; Latta, Kenneth S

    2008-01-01

    The most recent changes to Chapter 797 of the United States Pharmacopeia-National Formulary initiated an intense controversy about the frequency of cleanroom air sampling that is required to prevent the contamination of sterile preparations. For compounders who must purchase an air sampler to use in the cleanroom, choices abound. This article summarizes discussions from compounding pharmacists and their experiences with air sampling devices.

  20. Toxicological Assessment of ISS Air Quality: Contingency Sampling - February 2013

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie

    2013-01-01

    Two grab sample containers (GSCs) were collected by crew members onboard ISS in response to a vinegar-like odor in the US Lab. On February 5, the first sample was collected approximately 1 hour after the odor was noted by the crew in the forward portion of the Lab. The second sample was collected on February 22 when a similar odor was noted and localized to the end ports of the microgravity science glovebox (MSG). The crewmember removed a glove from the MSG and collected the GSC inside the glovebox volume. Both samples were returned on SpaceX-2 for ground analysis.

  1. Sample Results From The Interim Salt Disposition Program Macrobatch 6 Tank 21H Qualification Samples

    SciTech Connect

    Peters, T. B.; Fink, S. D.

    2012-12-20

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 6 for the Interim Salt Disposition Project (ISDP). This document reports partial results of the analyses of samples of Tank 21H. No issues with the projected Salt Batch 6 strategy are identified.

  2. Sample Results from the Interim Salt Disposition Program Macrobatch 6 Tank 21H Qualification Samples

    SciTech Connect

    Peters, T. B.; Fink, S. D.

    2012-12-11

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 6 for the Interim Salt Disposition Project (ISDP). This document reports partial results of the analyses of samples of Tank 21H. No issues with the projected Salt Batch 6 strategy are identified.

  3. Organic toxicants in air and precipitation samples from the Lake Michigan area

    SciTech Connect

    Harlin, K.S.; Sweet, C.W.; Gatz, D.F.

    1995-12-31

    Measurements of PCBs, organochlorine insecticides, PAHs, and atrazine were made in air and precipitation samples collected at regionally-representative locations near Lake Michigan from 1992-1995. The purpose of these measurements was to provide information needed to estimate the atmospheric deposition of organic toxicants to Lake Michigan. Twenty-four hour samples of airborne particles and vapor were collected at 12-day intervals on quartz fiber filters and XAD-2 resin vapor traps using modified high volume sampleers. Twenty-eight day precipitation samples were collected using wet-only samplers with stainless steel sampling surfaces and heated enclosure containing an XAD-2 resin adsorption column. Samples were Soxhlet extracted for 24 hours with hexane:acetone (1:1), and concentrated by rotary evaporation. Interferences were removed and the samples separated into analyte groups by silica gel chromatography. Four fractions were collected for GC-ECD and GC-Ion Trap MS analyses. Ten pesticides, 101 PCB congeners, 18 PAHs, and atrazine were measured in all samples. Quality assurance was maintained by including field duplicate samples, field blanks, alboratory matrix spikes, laboratory matrix blanks, and laboratory surrogate spikes in the sampling/analytical protocols. Preliminary results from urban and remote sites show geographical variations in the concentrations of some toxicants due to contributions from local sources. For all sites the total PCB levels are higher in the vapor phase than the particulate phase and show strong seasonal variations. Seasonal variations were also observed for several pesticides.

  4. GICHD Mine Dog Testing Project - Soil Sample Results No.3

    SciTech Connect

    PHELAN, JAMES M.; BARNETT, JAMES L.; BENDER, SUSAN FAE ANN; ARCHULETA, LUISA M.

    2003-03-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonal weather conditions. This report documents the analytical chemical methods and results from the third batch of soils received. This batch contained samples from Kharga, Afghanistan collected in October 2002.

  5. GICHD mine dog testing project - soil sample results #4.

    SciTech Connect

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.; Wood, Tyson B.; Donovan, Kelly L.; Bender, Susan Fae Ann

    2003-08-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan and Bosnia containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonal weather conditions. This report documents the analytical chemical methods and results from the fourth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in April 2003 and Sarajevo, Bosnia collected in May 2003.

  6. GICHD mine dog testing project : soil sample results #5.

    SciTech Connect

    Barnett, James L.; Phelan, James M.; Archuleta, Luisa M.; Donovan, Kelly L.; Bender, Susan Fae Ann

    2004-01-01

    A mine dog evaluation project initiated by the Geneva International Center for Humanitarian Demining is evaluating the capability and reliability of mine detection dogs. The performance of field-operational mine detection dogs will be measured in test minefields in Afghanistan containing actual, but unfused landmines. Repeated performance testing over two years through various seasonal weather conditions will provide data simulating near real world conditions. Soil samples will be obtained adjacent to the buried targets repeatedly over the course of the test. Chemical analysis results from these soil samples will be used to evaluate correlations between mine dog detection performance and seasonal weather conditions. This report documents the analytical chemical methods and results from the fifth batch of soils received. This batch contained samples from Kharga, Afghanistan collected in June 2003.

  7. Determination of methyl bromide in air samples by headspace gas chromatography

    SciTech Connect

    Woodrow, J.E.; McChesney, M.M.; Seiber, J.N.

    1988-03-01

    Methyl bromide is extensively used in agriculture (4 x 10/sup 6/ kg for 1985 in California alone as a fumigant to control nematodes, weeds, and fungi in soil and insect pests in harvested grains and nuts. Given its low boiling point (3.8/sup 0/C) and high vapor pressure (approx. 1400 Torr at 20/sup 0/C), methyl bromide will readily diffuse if not rigorously contained. Methods for determining methyl bromide and other halocarbons in air vary widely. A common practice is to trap the material from air on an adsorbent, such as polymeric resins, followed by thermal desorption either directly into the analytical instrumentation or after intermediary cryofocusing. While in some cases analytical detection limits were reasonable (parts per million range), many of the published methods were labor intensive and required special handling techniques that precluded high sample throughput. They describe here a method for the sampling and analysis of airborne methyl bromide that was designed to handle large numbers of samples through automating some critical steps of the analysis. The result was a method that allowed around-the-clock operation with a minimum of operator attention. Furthermore, the method was not specific to methyl bromide and could be used to determine other halocarbons in air.

  8. Polyurethane foam (PUF) disks passive air samplers: wind effect on sampling rates.

    PubMed

    Tuduri, Ludovic; Harner, Tom; Hung, Hayley

    2006-11-01

    Different passive sampler housings were evaluated for their wind dampening ability and how this might translate to variability in sampler uptake rates. Polyurethane foam (PUF) disk samplers were used as the sampling medium and were exposed to a PCB-contaminated atmosphere in a wind tunnel. The effect of outside wind speed on PUF disk sampling rates was evaluated by exposing polyurethane foam (PUF) disks to a PCB-contaminated air stream in a wind tunnel over air velocities in the range 0 to 1.75 m s-1. PUF disk sampling rates increased gradually over the range 0-0.9 m s-1 at approximately 4.5-14.6 m3 d-1 and then increased sharply to approximately 42 m3 d-1 at approximately 1.75 m s-1 (sum of PCBs). The results indicate that for most field deployments the conventional 'flying saucer' housing adequately dampens the wind effect and will yield approximately time-weighted air concentrations.

  9. Low-cost monitoring of Campylobacter in poultry houses by air sampling and quantitative PCR.

    PubMed

    Søndergaard, M S R; Josefsen, M H; Löfström, C; Christensen, L S; Wieczorek, K; Osek, J; Hoorfar, J

    2014-02-01

    The present study describes the evaluation of a method for the quantification of Campylobacter by air sampling in poultry houses. Sampling was carried out in conventional chicken houses in Poland, in addition to a preliminary sampling in Denmark. Each measurement consisted of three air samples, two standard boot swab fecal samples, and one airborne particle count. Sampling was conducted over an 8-week period in three flocks, assessing the presence and levels of Campylobacter in boot swabs and air samples using quantitative real-time PCR. The detection limit for air sampling was approximately 100 Campylobacter cell equivalents (CCE)/m3. Airborne particle counts were used to analyze the size distribution of airborne particles (0.3 to 10 μm) in the chicken houses in relation to the level of airborne Campylobacter. No correlation was found. Using air sampling, Campylobacter was detected in the flocks right away, while boot swab samples were positive after 2 weeks. All samples collected were positive for Campylobacter from week 2 through the rest of the rearing period for both sampling techniques, although levels 1- to 2-log CCE higher were found with air sampling. At week 8, the levels were approximately 10(4) and 10(5) CCE per sample for boot swabs and air, respectively. In conclusion, using air samples combined with quantitative real-time PCR, Campylobacter contamination could be detected earlier than by boot swabs and was found to be a more convenient technique for monitoring and/or to obtain enumeration data useful for quantitative risk assessment of Campylobacter.

  10. Effect of sample stratification on dairy GWAS results

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Background Artificial insemination and genetic selection are major factors contributing to population stratification in dairy cattle. In this study, we analyzed the effect of sample stratification and the effect of stratification correction on results of a dairy genome-wide association study (GWAS)....

  11. Aquifer Sampling Tube Results for Fiscal Year 2003

    SciTech Connect

    Hartman, Mary J.; Peterson, Robert E.

    2003-10-27

    This report presents and discusses results of the fiscal year 2003 sampling event associated with aquifer tubes along the Columbia River in the northern Hanford Site. Aquifer tube data help define the extent of groundwater contamination near the river, determine vertical variations in contamination, monitor the performance of interim remedial actions near the river, and support impact studies.

  12. Passive sampling of glycol ethers and their acetates in indoor air.

    PubMed

    Plaisance, H; Desmettres, P; Leonardis, T; Pennequin-Cardinal, A; Locoge, N; Galloo, J-C

    2008-04-01

    This study examined the performances of a thermal desorbable radial diffusive sampler for the weekly measurement of eight glycol ethers in indoor air and described the results of an application of this method carried out as part of HABIT'AIR Nord - Pas de Calais program for the air monitoring of these compounds in sixty homes located in northern France. The target compounds were the four glycol ethers banned from sale to the public in France since the 1990s (i.e. 2-methoxy ethanol, 2-ethoxy ethanol and their acetates) and four other glycol ethers derivatives of which the use have increased considerably (i.e. 1-methoxy-2-propanol, 2-butoxy ethanol and their acetates).A test program was carried out with the aim of validating the passive sampling method. It allowed the estimation of all the parameters of a method for each compound (calibration, analytical precision, desorption efficiency, sampling rate in standard conditions, detection limit and stability of sample before and after exposure), the examination of the influence of environmental factors on the sampling rate by some exposure chamber experiments and the assessment of the uncertainty of the measurements. The results of this evaluation demonstrated that the method has turned out to be suitable for six out of eight glycol ethers tested. The effect of the environmental factors on the sampling rates was the main source of measurement uncertainty. The measurements done in sixty homes revealed a relative abundance of 1-methoxy-2-propanol that was found in more than two thirds of homes at concentration levels of 4.5 microg m(-3) on average (a maximum value of 28 microg m(-3)). 1-methoxy-2-propanol acetate and 2-butoxy ethanol were also detected, but less frequently (in 19% of homes) and with the concentrations below 12 microg m(-3). The highest levels of these glycol ethers appear to be in relation to the emissions occurring at the time of cleaning tasks.

  13. Sampling size in the verification of manufactured-supplied air kerma strengths

    SciTech Connect

    Ramos, Luis Isaac; Martinez Monge, Rafael

    2005-11-15

    Quality control mandate that the air kerma strengths (S{sub K}) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to an a priori statistical level of uncertainty. The results are based on the assumption that the S{sub K} has a normal distribution. To demonstrate this, the S{sub K} of each of the seeds measured was corrected to ensure that the average S{sub K} of its sample remained the same. In this process 2030 results were collected and analyzed using a normal plot. In our opinion, the number of seeds sampled should be determined beforehand according to an a priori level of statistical uncertainty.

  14. SAMPLE RESULTS FROM THE INTEGRATED SALT DISPOSITION PROGRAM MACROBATCH 5 TANK 21H QUALIFICATION SAMPLES

    SciTech Connect

    Peters, T.; Fink, S.

    2012-03-26

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 5 for the Integrated Salt Disposition Project (ISDP). This document reports partial results of the analyses of samples of Tank 21H. No issues with the projected Salt Batch 5 strategy are identified. Results of the analyses of the Tank 21H samples from this report in conjunction with the findings of the previous report, indicates that the material does not display any unusual characteristics.

  15. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  16. Air sampling to recover variola virus in the environment of a smallpox hospital.

    PubMed

    MEIKLEJOHN, G; KEMPE, C H; DOWNIE, A W; BERGE, T O; ST VINCENT, L; RAO, A R

    1961-01-01

    The view is widely held that variola is highly infectious, and it was therefore thought of interest to obtain precise information on the amount of virus disseminated in the air by smallpox patients at various stages of their illness. To this end, measured samples of air in and around the smallpox wards of the Infectious Diseases Hospital, Madras, were tested for the presence of variola virus. Surprisingly, virus was recovered on one occasion only by the air sampling device used. All other tests were negative although large volumes of air were sampled in close proximity to patients at various stages of the disease. The authors consider that further observations should be made with more sensitive air sampling methods.

  17. Sample Results From Tank 48H Samples HTF-48-14-158, -159, -169, and -170

    SciTech Connect

    Peters, T.; Hang, T.

    2015-04-28

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 48H in support of determining the cause for the unusually high dose rates at the sampling points for this tank. A set of two samples was taken from the quiescent tank, and two additional samples were taken after the contents of the tank were mixed. The results of the analyses of all the samples show that the contents of the tank have changed very little since the analysis of the previous sample in 2012. The solids are almost exclusively composed of tetraphenylborate (TPB) salts, and there is no indication of acceleration in the TPB decomposition. The filtrate composition shows a moderate increase in salt concentration and density, which is attributable to the addition of NaOH for the purposes of corrosion control. An older modeling simulation of the TPB degradation was updated, and the supernate results from a 2012 sample were run in the model. This result was compared to the results from the 2014 recent sample results reported in this document. The model indicates there is no change in the TPB degradation from 2012 to 2014. SRNL measured the buoyancy of the TPB solids in Tank 48H simulant solutions. It was determined that a solution of density 1.279 g/mL (~6.5M sodium) was capable of indefinitely suspending the TPB solids evenly throughout the solution. A solution of density 1.296 g/mL (~7M sodium) caused a significant fraction of the solids to float on the solution surface. As the experiments could not include the effect of additional buoyancy elements such as benzene or hydrogen generation, the buoyancy measurements provide an upper bound estimate of the density in Tank 48H required to float the solids.

  18. Review of the Physical Science Facility Stack Air Sampling Probe Locations

    SciTech Connect

    Glissmeyer, John A.

    2007-09-30

    This letter report reviews compliance of the current design of the Physical Science Facility (PSF) stack air sampling locations with the ANSI/HPS N13.1-1999 standard. The review was based on performance criteria used for locating air sampling probes, the design documents provided and available information on systems previously tested for compliance with the criteria. Recommendations are presented for ways to bring the design into compliance with the requirements for the sampling probe placement.

  19. Radiological air monitoring and sample analysis research and development progress report. Calendar year, 1992

    SciTech Connect

    Not Available

    1992-12-31

    Sponsored by a Department Of Energy (DOE) research and development grant, the State of Idaho INEL Oversight Program (OP) personnel designed an independent air monitoring system that provides detection of the presence of priority airborne contaminants potentially migrating beyond INEL boundaries. Initial locations for off-site ambient air monitoring stations were chosen in consultation with: DOE and NOAA reports; Mesodif modeling; review of the relevant literature; and communication with private contractors and experts in pertinent fields. Idaho State University (ISU) has initiated an Environmental Monitoring Program (EMP). The EMP provides an independent monitoring function as well as a training ground for students. Students learn research techniques dedicated to environmental studies and learn analytical skills and rules of compliance related to monitoring. ISU-EMP assisted OP in specific aspects of identifying optimum permanent monitoring station locations, and in selecting appropriate sample collection equipment for each station. The authorization to establish, prepare and install sampling devices on selected sites was obtained by OP personnel in conjunction with ISU-EMP personnel. All samples described in this program are collected by OP or ISU-EMP personnel and returned to the ISU for analysis. This report represents the summary of results of those samples collected and analyzed for radioactivity during the year of 1992.

  20. Summary of Test Results for Daya Bay Rock Samples

    SciTech Connect

    Onishi, Celia Tiemi; Dobson, Patrick; Nakagawa, Seiji

    2004-10-12

    A series of analytical tests was conducted on a suite of granitic rock samples from the Daya Bay region of southeast China. The objective of these analyses was to determine key rock properties that would affect the suitability of this location for the siting of a neutrino oscillation experiment. This report contains the results of chemical analyses, rock property measurements, and a calculation of the mean atomic weight.

  1. Summary of stationary and personal air sampling measurements made during a plutonium glovebox decommissioning project.

    SciTech Connect

    Munyon, W. J.; Lee, M. B.

    2002-02-01

    Workplace air sampling was performed during the decommissioning of a previously active plutonium glovebox facility located at Argonne National Laboratory. Personal air samplers (PAS) were used to measure breathing zone activity concentrations of workers engaged in size-reducing contaminated gloveboxes. Stationary air samplers (SAS) were used to measure the work area activity concentrations and test their application in providing representative sampling of breathing zone activity concentrations. The relative response of these samplers (PAS:SAS) was tracked during the course of the decommissioning work, with results yielding favorable agreement to within a factor of {+-}5. A cascade impactor was used to determine the particle size distribution of workplace aerosols. The average activity median aerodynamic diameter (AMAD) was estimated to be 3.0 {mu}m, with a corresponding geometric standard deviation of 2.4. A gas-flow proportional counter was utilized to measure the gross alpha activity collected on both the SAS glass fiber and the PAS cellulose fiber filters. A subset of this filter group was subsequently analyzed using an alpha spectrometer post radiochemical processing and isotopic separation. The quantity of alpha activity measured on the SAS filters was generally within {+-}30% of the alpha spectrometry measurements. However, measurements made of the activity present on the PAS cellulose fiber filters were consistently underestimated using a gas-flow proportional counter, suggesting a small correction factor of 15-20% to account for the absorption of alpha particle emissions.

  2. Summary of stationary and personal air sampling measurements made during a plutonium glovebox decommissioning project.

    PubMed

    Munyon, W J; Lee, M B

    2002-02-01

    Workplace air sampling was performed during the decommissioning of a previously active plutonium glovebox facility located at Argonne National Laboratory. Personal air samplers (PAS) were used to measure breathing zone activity concentrations of workers engaged in size-reducing contaminated gloveboxes. Stationary air samplers (SAS) were used to measure the work area activity concentrations and test their application in providing representative sampling of breathing zone activity concentrations. The relative response of these samplers (PAS:SAS) was tracked during the course of the decommissioning work, with results yielding favorable agreement to within a factor of +/-5. A cascade impactor was used to determine the particle size distribution of workplace aerosols. The average activity median aerodynamic diameter (AMAD) was estimated to be 3.0 microm, with a corresponding geometric standard deviation of 2.4. A gas-flow proportional counter was utilized to measure the gross alpha activity collected on both the SAS glass fiber and the PAS cellulose fiber filters. A subset of this filter group was subsequently analyzed using an alpha spectrometer post radiochemical processing and isotopic separation. The quantity of alpha activity measured on the SAS filters was generally within +/-30% of the alpha spectrometry measurements. However, measurements made of the activity present on the PAS cellulose fiber filters were consistently underestimated using a gas-flow proportional counter, suggesting a small correction factor of 15-20% to account for the absorption of alpha particle emissions.

  3. Identification of monochloro-nonabromodiphenyl ethers in the air and soil samples from south China.

    PubMed

    Yu, Zhiqiang; Zheng, Kewen; Ren, Guofa; Wang, Decheng; Ma, Shengtao; Peng, Pingan; Wu, Minghong; Sheng, Guoying; Fu, Jiamo

    2011-04-01

    Several studies have indicated that mixed brominated/chlorinated organic compounds could be formed during the thermal process such as the incineration of municipal solid waste and open burning of unregulated e-waste at recycling areas. In this study, air particles and soils from e-waste recycling areas, as well as outdoor and indoor air particles from urban Guangzhou, were collected and pooled for the identification of mixed chlorinated/brominated diphenyl ethers (PXDEs). Three monochloro-nonabromo diphenyl ethers (Cl-nonaBDEs), including 6'-Cl-BDE-206, 5'-Cl-BDE-207, and/or 4'-Cl-BDE-208, were first structurally identified in these air and soil samples. The identification was done by comparison of retention times in chromatograms of pure reference compounds and environmental samples, as well as by comparison with full-scan mass spectra data in electron capture negative ionization mode. Because of their similar physical-chemical properties, 4'-Cl-BDE-208 and 5'-Cl-BDE-207 absolutely coeluted, even on a nonpolar DB-5 column. Further investigation is still needed to clarify these findings. Nevertheless, the results indicated that Cl-nonaBDEs would occur in various environmental matrices. Because the replacement of Br by Cl will change the physical-chemical properties of PBDE analogues, environmental occurrence, fate, and transport, the potential toxicity of PXDEs should be investigated.

  4. Amchitka Island, Alaska, Biological Monitoring Report 2011 Sampling Results

    SciTech Connect

    2013-09-01

    The Long-Term Surveillance and Maintenance (LTS&M) Plan for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Amchitka Island sites describes how LM plans to conduct its mission to protect human health and the environment at the three nuclear test sites located on Amchitka Island, Alaska. Amchitka Island, near the western end of the Aleutian Islands, is approximately 1,340 miles west-southwest of Anchorage, Alaska. Amchitka is part of the Aleutian Island Unit of the Alaska Maritime National Wildlife Refuge, which is administered by the U.S. Fish and Wildlife Service (USFWS). Since World War II, Amchitka has been used by multiple U.S. government agencies for various military and research activities. From 1943 to 1950, it was used as a forward air base for the U.S. Armed Forces. During the middle 1960s and early 1970s, the U.S. Department of Defense (DOD) and the U.S. Atomic Energy Commission (AEC) used a portion of the island as a site for underground nuclear tests. During the late 1980s and early 1990s, the U.S. Navy constructed and operated a radar station on the island. Three underground nuclear tests were conducted on Amchitka Island. DOD, in conjunction with AEC, conducted the first nuclear test (named Long Shot) in 1965 to provide data that would improve the United States' capability of detecting underground nuclear explosions. The second nuclear test (Milrow) was a weapons-related test conducted by AEC in 1969 as a means to study the feasibility of detonating a much larger device. Cannikin, the third nuclear test on Amchitka, was a weapons-related test detonated on November 6, 1971. With the exception of small concentrations of tritium detected in surface water shortly after the Long Shot test, radioactive fission products from the tests remain in the subsurface at each test location As a continuation of the environmental monitoring that has taken place on Amchitka Island since before 1965, LM in the summer of 2011 collected biological and

  5. Release of Free DNA by Membrane-Impaired Bacterial Aerosols Due to Aerosolization and Air Sampling

    PubMed Central

    Zhen, Huajun; Han, Taewon; Fennell, Donna E.

    2013-01-01

    We report here that stress experienced by bacteria due to aerosolization and air sampling can result in severe membrane impairment, leading to the release of DNA as free molecules. Escherichia coli and Bacillus atrophaeus bacteria were aerosolized and then either collected directly into liquid or collected using other collection media and then transferred into liquid. The amount of DNA released was quantified as the cell membrane damage index (ID), i.e., the number of 16S rRNA gene copies in the supernatant liquid relative to the total number in the bioaerosol sample. During aerosolization by a Collison nebulizer, the ID of E. coli and B. atrophaeus in the nebulizer suspension gradually increased during 60 min of continuous aerosolization. We found that the ID of bacteria during aerosolization was statistically significantly affected by the material of the Collison jar (glass > polycarbonate; P < 0.001) and by the bacterial species (E. coli > B. atrophaeus; P < 0.001). When E. coli was collected for 5 min by filtration, impaction, and impingement, its ID values were within the following ranges: 0.051 to 0.085, 0.16 to 0.37, and 0.068 to 0.23, respectively; when it was collected by electrostatic precipitation, the ID values (0.011 to 0.034) were significantly lower (P < 0.05) than those with other sampling methods. Air samples collected inside an equine facility for 2 h by filtration and impingement exhibited ID values in the range of 0.30 to 0.54. The data indicate that the amount of cell damage during bioaerosol sampling and the resulting release of DNA can be substantial and that this should be taken into account when analyzing bioaerosol samples. PMID:24096426

  6. Adolescent psychopathy and the big five: results from two samples.

    PubMed

    Lynam, Donald R; Caspi, Avshalom; Moffitt, Terrie E; Raine, Adrian; Loeber, Rolf; Stouthamer-Loeber, Magda

    2005-08-01

    The present study examines the relation between psychopathy and the Big Five dimensions of personality in two samples of adolescents. Specifically, the study tests the hypothesis that the aspect of psychopathy representing selfishness, callousness, and interpersonal manipulation (Factor 1) is most strongly associated with low Agreeableness, whereas the aspect of psychopathy representing impulsivity, instability, and social deviance (Factor 2) is associated with low Agreeableness, low Conscientiousness, and high Neuroticism. Data from 13- and 16-year-old boys and their mothers from two samples of the Pittsburgh Youth Study are used to test these hypotheses. Results were consistent across age and rating source in supporting the initial hypotheses, providing support for the construct of juvenile psychopathy and the interpretation of psychopathy as a constellation of traits drawn from a general model of personality functioning.

  7. Glyphosate-rich air samples induce IL-33, TSLP and generate IL-13 dependent airway inflammation.

    PubMed

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A; Adhikari, Atin

    2014-11-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4-/-, and IL-13-/- mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease. PMID:25172162

  8. Glyphosate–rich air samples induce IL–33, TSLP and generate IL–13 dependent airway inflammation

    PubMed Central

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M.; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A.; Adhikari, Atin

    2014-01-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4−/−, and IL-13−/− mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease. PMID:25172162

  9. Glyphosate-rich air samples induce IL-33, TSLP and generate IL-13 dependent airway inflammation.

    PubMed

    Kumar, Sudhir; Khodoun, Marat; Kettleson, Eric M; McKnight, Christopher; Reponen, Tiina; Grinshpun, Sergey A; Adhikari, Atin

    2014-11-01

    Several low weight molecules have often been implicated in the induction of occupational asthma. Glyphosate, a small molecule herbicide, is widely used in the world. There is a controversy regarding a role of glyphosate in developing asthma and rhinitis among farmers, the mechanism of which is unexplored. The aim of this study was to explore the mechanisms of glyphosate induced pulmonary pathology by utilizing murine models and real environmental samples. C57BL/6, TLR4-/-, and IL-13-/- mice inhaled extracts of glyphosate-rich air samples collected on farms during spraying of herbicides or inhaled different doses of glyphosate and ovalbumin. The cellular response, humoral response, and lung function of exposed mice were evaluated. Exposure to glyphosate-rich air samples as well as glyphosate alone to the lungs increased: eosinophil and neutrophil counts, mast cell degranulation, and production of IL-33, TSLP, IL-13, and IL-5. In contrast, in vivo systemic IL-4 production was not increased. Co-administration of ovalbumin with glyphosate did not substantially change the inflammatory immune response. However, IL-13-deficiency resulted in diminished inflammatory response but did not have a significant effect on airway resistance upon methacholine challenge after 7 or 21 days of glyphosate exposure. Glyphosate-rich farm air samples as well as glyphosate alone were found to induce pulmonary IL-13-dependent inflammation and promote Th2 type cytokines, but not IL-4 for glyphosate alone. This study, for the first time, provides evidence for the mechanism of glyphosate-induced occupational lung disease.

  10. SAMPLE RESULTS FROM THE INTEGRATED SALT DISPOSITION PROGRAM MACROBATCH 4 TANK 21H QUALIFICATION SAMPLES

    SciTech Connect

    Peters, T.; Fink, S.

    2011-06-22

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H to qualify them for use in the Integrated Salt Disposition Program (ISDP) Batch 4 processing. All sample results agree with expectations based on prior analyses where available. No issues with the projected Salt Batch 4 strategy are identified. This revision includes additional data points that were not available in the original issue of the document, such as additional plutonium results, the results of the monosodium titanate (MST) sorption test and the extraction, scrub strip (ESS) test. This report covers the revision to the Tank 21H qualification sample results for Macrobatch (Salt Batch) 4 of the Integrated Salt Disposition Program (ISDP). A previous document covers initial characterization which includes results for a number of non-radiological analytes. These results were used to perform aluminum solubility modeling to determine the hydroxide needs for Salt Batch 4 to prevent the precipitation of solids. Sodium hydroxide was then added to Tank 21 and additional samples were pulled for the analyses discussed in this report. This work was specified by Task Technical Request and by Task Technical and Quality Assurance Plan (TTQAP).

  11. A method to optimize sampling locations for measuring indoor air distributions

    NASA Astrophysics Data System (ADS)

    Huang, Yan; Shen, Xiong; Li, Jianmin; Li, Bingye; Duan, Ran; Lin, Chao-Hsin; Liu, Junjie; Chen, Qingyan

    2015-02-01

    Indoor air distributions, such as the distributions of air temperature, air velocity, and contaminant concentrations, are very important to occupants' health and comfort in enclosed spaces. When point data is collected for interpolation to form field distributions, the sampling locations (the locations of the point sensors) have a significant effect on time invested, labor costs and measuring accuracy on field interpolation. This investigation compared two different sampling methods: the grid method and the gradient-based method, for determining sampling locations. The two methods were applied to obtain point air parameter data in an office room and in a section of an economy-class aircraft cabin. The point data obtained was then interpolated to form field distributions by the ordinary Kriging method. Our error analysis shows that the gradient-based sampling method has 32.6% smaller error of interpolation than the grid sampling method. We acquired the function between the interpolation errors and the sampling size (the number of sampling points). According to the function, the sampling size has an optimal value and the maximum sampling size can be determined by the sensor and system errors. This study recommends the gradient-based sampling method for measuring indoor air distributions.

  12. Discrepant results from sampling different lumens of multilumen catheters: the case for sampling all lumens.

    PubMed

    Cuellar-Rodriguez, J; Connor, D; Murray, P; Gea-Banacloche, J

    2014-05-01

    It is unclear whether blood culture samples should be obtained through one or multiple catheter lumens. We measured how frequently drawing blood cultures from all the lumens from a multilumen catheter resulted in discordant results and how often these caused medical interventions. We performed a retrospective review of the microbiology database of the National Institutes of Health (NIH) Clinical Center. Most patients were immunocompromised. All blood cultures obtained from May 1, 2007 to April 30, 2009 were reviewed. We analyzed all positive blood cultures (i.e., positivity of any of the blood cultures drawn through the catheter lumens) when simultaneous samples from different lumens were obtained, and reviewed the medical charts of those in which blood cultures from different lumens had discordant results (i.e., not all lumens revealed the same organism). We also analyzed how often the discordant results lead to a medical intervention, defined as a change of antimicrobials and/or removal of the catheter. There were 405 episodes of positive blood cultures, in which simultaneous samples of different lumens of a multilumen catheter were obtained. Eighty-five episodes (21 %) were considered to be contaminants and excluded. We analyzed 320 episodes of positive blood cultures in 153 patients; 173 episodes (54.1 %) had discordant results. In 77 % of the 173 episodes, the discordant isolate led to a medical intervention. In immunocompromised patients, sampling all the lumens of a multilumen catheter results in more positive blood cultures, and many of these result in medical interventions. When evaluating bloodstream infection in patients with multilumen catheters, sampling all lumens should be strongly considered.

  13. Mixed species radioiodine air sampling readout and dose assessment system

    DOEpatents

    Distenfeld, Carl H.; Klemish, Jr., Joseph R.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector.

  14. Results of toxicological testing of Jefferson Parish pilot plant samples.

    PubMed Central

    Miller, R G; Kopfler, F C; Condie, L W; Pereira, M A; Meier, J R; Ringhand, H P; Robinson, M; Casto, B C

    1986-01-01

    Five toxicological tests were performed using concentrated drinking water samples collected at a pilot-scale drinking water treatment plant that had streams treated with different disinfectants (no disinfectant, ozone, chlorine dioxide, monochloramine, or chlorine) before treatment with granular activated carbon (GAC). The toxicological tests used in this study were the Ames Salmonella assay, a subchronic in vivo toxicity assay in mice, the SENCAR mouse skin initiation-promotion assay, a rat liver foci assay, and the lung adenoma assay in strain A mice. These tests were conducted to determine the general toxicity and the mutagenic/carcinogenic potential associated with the use of disinfection and/or GAC in the treatment of drinking water. The stability of the mutagenic activity of the samples tested was determined by repeated analysis using the Ames Salmonella assay. Results indicated that the samples remained mutagenic for the duration of the tests. All the drinking water concentrates (4000 X) prepared by the XAD resin adsorption procedure failed to provide statistically significant indication of carcinogenic activity in the SENCAR mouse, rat liver foci, and the lung adenoma assays. However, concentrates of the chlorine, chlorine dioxide, and monochloramine treated waters gave consistent mutagenic responses in the Ames Salmonella assay. GAC was effective for 6 months in removing both the mutagenicity of chlorine-treated water and the potential of water to become mutagenic when treated with chlorine. In the in vivo, subchronic 30-day toxicity test in mice, some statistically significant differences in organ weights and body weights of animals exposed to different concentrates of some of the samples were observed. However, a consistent pattern of these differences indicating overt toxicity was not detected. PMID:3816718

  15. Automated syringe sampler. [remote sampling of air and water

    NASA Technical Reports Server (NTRS)

    Purgold, G. C. (Inventor)

    1981-01-01

    A number of sampling services are disposed in a rack which slides into a housing. In response to a signal from an antenna, the circutry elements are activated which provide power individually, collectively, or selectively to a servomechanism thereby moving an actuator arm and the attached jawed bracket supporting an evaculated tube towards a stationary needle. One open end of the needle extends through the side wall of a conduit to the interior and the other open end is maintained within the protective sleeve, supported by a bifurcated bracket. A septum in punctured by the end of the needle within the sleeve and a sample of the fluid medium in the conduit flows through the needle and is transferred to a tube. The signal to the servo is then reversed and the actuator arm moves the tube back to its original position permitting the septum to expand and seal the hole made by the needle. The jawed bracket is attached by pivot to the actuator to facilitate tube replacement.

  16. Sampling and Analyzing Air Pollution: An Apparatus Suitable for Use in Schools.

    ERIC Educational Resources Information Center

    Rockwell, Dean M.; Hansen, Tony

    1994-01-01

    Describes two variations of an air sampler and analyzer that are inexpensive to construct, easy to operate, and designed to be used in an educational program. Variations use vacuum cleaners and aquarium pumps, and white facial tissues serve as filters. Samples of air pollution obtained by this method may be used from early grade school to advanced…

  17. Variables Related to Pre-Service Cannabis Use in a Sample of Air Force Enlistees.

    ERIC Educational Resources Information Center

    Mullins, Cecil J.; And Others

    This report is an attempt to add to the existing information about cannabis use, its correlates, and its effects. The sample population consisted of self-admitted abusers of various drugs, identified shortly after entering the Air Force. The subjects (N=4688) were located through the Drug Control Office at Lackland Air Force Base. Variables…

  18. Salmonella recovery following air chilling for matched neck-skin and whole carcass sampling methodologies

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The prevalence and serogroups of Salmonella recovered following air chilling were determined for both enriched neck skin and matching enriched whole carcass samples. Commercially processed and eviscerated carcasses were air chilled to 4C before removing the neck skin (8.3 g) and stomaching in 83 mL...

  19. Solvent-free sampling with di-n-butylamine for monitoring of isocyanates in air.

    PubMed

    Marand, Asa; Karlsson, Daniel; Dalene, Marianne; Skarping, Gunnar

    2005-04-01

    The solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar amounts of di-n-butylamine (DBA) and acetic acid. Air sampling was performed with an air flow of 0.2 l min(-1). The formed isocyanate-DBA derivatives were determined using liquid chromatography and tandem mass spectrometry. The sampler was investigated in regard to collection principle and extraction of the formed derivatives with good results. The possibility to store the sampler before sampling and to perform long-term sampling was demonstrated. Field extraction of the sampler was not necessary, as there was no difference between immediately extracted samples and stored ones (2 days). In comparative studies, the sampler was evaluated against a reference method, impinger-filter sampling with DBA as reagent. The ratios between the results obtained with the sampler and the reference in a test chamber at a relative humidity (RH) of 45% was in the range of 83-109% for isocyanates formed during thermal decomposition of PUR. At RH 95%, the range was 72-101% with the exception of isocyanic acid. In two field evaluations, the ratios for fast curing 2,4'- and 4,4'-methylene bisphenyl diisocyanate (MDI) was in the range 81-113% and for the 3-ring MDI the range was 54-70%. For the slower curing 1,6-hexamethylene diisocyanate (HDI) and HDI isocyanurate, the ratios were in the range 78-145%. In conclusion, the solvent-free sampler is a convenient alternative in most applications to the more cumbersome impinger-filter sampler.

  20. Evaluation of Observation-Fused Regional Air Quality Model Results for Population Air Pollution Exposure Estimation

    PubMed Central

    Chen, Gang; Li, Jingyi; Ying, Qi; Sherman, Seth; Perkins, Neil; Rajeshwari, Sundaram; Mendola, Pauline

    2014-01-01

    In this study, Community Multiscale Air Quality (CMAQ) model was applied to predict ambient gaseous and particulate concentrations during 2001 to 2010 in 15 hospital referral regions (HRRs) using a 36-km horizontal resolution domain. An inverse distance weighting based method was applied to produce exposure estimates based on observation-fused regional pollutant concentration fields using the differences between observations and predictions at grid cells where air quality monitors were located. Although the raw CMAQ model is capable of producing satisfying results for O3 and PM2.5 based on EPA guidelines, using the observation data fusing technique to correct CMAQ predictions leads to significant improvement of model performance for all gaseous and particulate pollutants. Regional average concentrations were calculated using five different methods: 1) inverse distance weighting of observation data alone, 2) raw CMAQ results, 3) observation-fused CMAQ results, 4) population-averaged raw CMAQ results and 5) population-averaged fused CMAQ results. It shows that while O3 (as well as NOx) monitoring networks in the HRR regions are dense enough to provide consistent regional average exposure estimation based on monitoring data alone, PM2.5 observation sites (as well as monitors for CO, SO2, PM10 and PM2.5 components) are usually sparse and the difference between the average concentrations estimated by the inverse distance interpolated observations, raw CMAQ and fused CMAQ results can be significantly different. Population-weighted average should be used to account spatial variation in pollutant concentration and population density. Using raw CMAQ results or observations alone might lead to significant biases in health outcome analyses. PMID:24747248

  1. TECHNOLOGY EVALUATION REPORT CEREX ENVIRONMENTAL SERVICES UV HOUND POINT SAMPLE AIR MONITOR

    EPA Science Inventory

    The USEPA's National Homeland Security Research Center (NHSRC) Technology Testing and Evaluation Program (TTEP) is carrying out performance tests on homeland security technologies. Under TTEP, Battelle evaluated the performance of the Cerex UV Hound point sample air monitor in de...

  2. NEW APPLICATION OF PASSIVE SAMPLING DEVICES FOR ASSESSMENT OF RESPIRATORY EXPOSURE TO PESTICIDES IN INDOOR AIR

    EPA Science Inventory

    The United States Environmental Protection Agency (EPA) has long maintained an interest in potential applications of passive sampling devices (PSDs) for estimating the concentrations of various pollutants in air. Typically PSDs were designed for the workplace monitoring of vola...

  3. Comparison of stationary and personal air sampling with an air dispersion model for children’s ambient exposure to manganese

    EPA Science Inventory

    Manganese (Mn) is ubiquitous in the environment and essential for normal growth and development, yet excessive exposure can lead to impairments in neurological function. This study modeled ambient Mn concentrations as an alternative to stationary and personal air sampling to asse...

  4. Air Quality Campaign Results from the Langley Mobile Ozone Lidar

    NASA Astrophysics Data System (ADS)

    De Young, R.; Carrion, W.; Pliutau, D.; Gano, R.

    2014-12-01

    A compact differential absorption ozone lidar (DIAL) system has been developed called the Langley Mobile Ozone Lidar (L-MOL) which can provide ozone, aerosol and cloud atmospheric profiles from a mobile trailer for ground-based atmospheric air quality campaigns. This lidar is integrated into the Tropospheric Ozone Lidar Network (TOLNet) currently made up of four other ozone lidars, three of which are mobile, across the country. The laser transmitter consist of a Coherent Evolution 30 TEM00 1-kHz diode pumped Q-switched Nd:YLF inter-cavity doubled laser pumping a Ce:LiCAF tunable UV laser. The transmitter transmits ~60 mW at two wavelengths between 280 and 293-nm for ozone and 2.5-W at 527-nm for aerosol profiling. The lidar operates at 1-kHz with 500-Hz at each 0f two UV wavelength. A fiber coupled 40-cm diameter parabolic telescope collets the backscattered return and records analog and photon counting signals. A separate 30-cm diameter telescope collects very near field returns for ozone profiles close to the surface. The lidar is capable of recording ozone profiles from 100-500-m with the very near field telescope and from 800-m to approximately 6000-m with the far field channel depending on sky background conditions. The system has been configured to enable mobile operation from a trailer which is environmentally controlled, and is towed with a truck with the objective to make the system mobile such that it can be setup at remote sites to support air quality field campaigns such as the July-August 2014 Denver, CO DISCOVER_AQ campaign. Before the lidar was deployed in the DISCOVER-AQ campaign the lidar operated for 15 hours at NASA Langley in Hampton, VA to test the ability of the system to accurately record ozone profiles. The figure below shows the results of that test. Six ozonesondes were launched during this period and show reasonable agreement with the ozone (ppbv) curtain plot. Ozone of stratospheric origin at 4-14 UTC was noted as well as local ozone

  5. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration. PMID:21793731

  6. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    PubMed

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.

  7. Evaluation of Environmental Sample Analysis Methods and Results Reporting in the National Children's Study Vanguard Study.

    PubMed

    Heikkinen, Maire S A; Khalaf, Abdisalam; Beard, Barbara; Viet, Susan M; Dellarco, Michael

    2016-05-01

    During the initial Vanguard phase of the U.S. National Children's Study (NCS), about 2000 tap water, surface wipe, and air samples were collected and analyzed immediately. The shipping conditions, analysis methods, results, and laboratory performance were evaluated to determine the best approaches for use in the NCS Main Study. The main conclusions were (1) to employ established sample analysis methods, when possible, and alternate methodologies only after careful consideration with method validation studies; (2) lot control and prescreening sample collection materials are important quality assurance procedures; (3) packing samples correctly requires careful training and adjustment of shipping conditions to local conditions; (4) trip blanks and spiked samples should be considered for samplers with short expiration times and labile analytes; (5) two study-specific results reports should be required: laboratory electronic data deliverables (EDD) of sample results in a useable electronic format (CSV or SEDD XML/CSV) and a data package with sample results and supporting information in PDF format. These experiences and lessons learned can be applied to any long-term study.

  8. Venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms

    NASA Technical Reports Server (NTRS)

    Hill, Gerald F.; Sachse, Glen W.; Young, Douglas C.; Wade, Larry O.; Burney, Lewis G.

    1992-01-01

    Documentation of the installation and use of venturi air-jet vacuum ejectors for high-volume atmospheric sampling on aircraft platforms is presented. Information on the types of venturis that are useful for meeting the pumping requirements of atmospheric-sampling experiments is also presented. A description of the configuration and installation of the venturi system vacuum line is included with details on the modifications that were made to adapt a venturi to the NASA Electra aircraft at GSFC, Wallops Flight Facility. Flight test results are given for several venturis with emphasis on applications to the Differential Absorption Carbon Monoxide Measurement (DACOM) system at LaRC. This is a source document for atmospheric scientists interested in using the venturi systems installed on the NASA Electra or adapting the technology to other aircraft.

  9. Effect of sample quantity on the results of ferromagnetic resonance studies of lunar samples

    NASA Technical Reports Server (NTRS)

    Goldberg, J. B.; Crowe, H. R.; Housley, R. M.; Cirlin, E. H.

    1979-01-01

    Quantitative ferromagnetic resonance (FMR) measurements at 9.5 and 35 GHz were made on lunar fines in order to determine the amount of single domain FE(0) and to ascertain the effect of sample quantity on the results of these experiments. Samples containing more than 10 micrograms of Fe(0) in an X-band TE(104) cavity, or more than 0.11 micrograms in a Ka-band cavity can cause errors greater than 1% in the quantitative determination of Fe(0), as well as cause anomalous broadening of the FMR line. Theoretical calculations were derived to show this effect which results from a nonlinear response of the FMR experiment with the sample quantity. Using samples of nominal weights, the amount of Fe(0) determined at 34 GHz was 1.1-1.8 times greater than at 9.5 GHz, while the linewidths increased by a factor of 1.2. As the particle size increases, the ratio of Fe(0) determined at 35 GHz to that determined at 9.5 GHz increases, suggesting that the additional iron is due to larger spheroidal particles which change from multidomain to single domain at the larger fields.

  10. Results of toxicological testing of Jefferson Paris pilot plant samples

    SciTech Connect

    Miller, R.G.; Kopfler, F.C.; Condie, L.W.; Pereira, M.A.; Meier, J.R.; Ringhand, H.P.; Robinson, M.; Casto, B.C.

    1986-11-01

    Five toxicological tests were performed using concentrated drinking water samples collected at a pilot-scale drinking water treatment plant that had streams treated with different disinfectants (no disinfectant, ozone, chlorine dioxide, monochloramine, or chlorine) before treatment with granular activated carbon (GAC). The toxicological tests used in this study were the Ames Salmonella assay, a subchronic in vivo toxicity assay in mice, the SENCAR mouse skin initiation-promotion assay, a rat liver foci assay, and the lung adenoma assay in strain A mice. These tests were conducted to determine the general toxicity and the mutagenic/carcinogenic potential association with the use of disinfection and/or GAC in the treatment of drinking water. Results indicated that the samples remained mutagenic for the duration of the tests. All the drinking water concentrates (4000 x) prepared by the XAD resin adsorption procedure failed to provide statistically significant indication of carcinogenic activity in the SENCAR mouse, rat liver foci, and the lung adenoma assays. However, concentrates of the chlorine, chlorine dioxide, and monochloramine treated waters gave consistent mutagenic responses in the Ames Salmonella assay. GAC was effective for 6 months in removing both the mutagenicity of chlorine-treated water and the potential of water to become mutagenic when treated with chlorine. A consistent pattern of these differences indicating overt toxicity was not detected.

  11. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Rubino, M.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2012-07-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change must have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological changes in the CFC production process over the last 80 yr. Propagating the mass-balance calculations into the future demonstrates that as emissions decrease to zero, isotopic fractionation by the stratospheric sinks will lead to continued 13C enrichment in atmospheric CFC-12.

  12. Extreme 13C depletion of CCl2F2 in firn air samples from NEEM, Greenland

    NASA Astrophysics Data System (ADS)

    Zuiderweg, A.; Holzinger, R.; Martinerie, P.; Schneider, R.; Kaiser, J.; Witrant, E.; Etheridge, D.; Petrenko, V.; Blunier, T.; Röckmann, T.

    2013-01-01

    A series of 12 high volume air samples collected from the S2 firn core during the North Greenland Eemian Ice Drilling (NEEM) 2009 campaign have been measured for mixing ratio and stable carbon isotope composition of the chlorofluorocarbon CFC-12 (CCl2F2). While the mixing ratio measurements compare favorably to other firn air studies, the isotope results show extreme 13C depletion at the deepest measurable depth (65 m), to values lower than δ13C = -80‰ vs. VPDB (the international stable carbon isotope scale), compared to present day surface tropospheric measurements near -40‰. Firn air modeling was used to interpret these measurements. Reconstructed atmospheric time series indicate even larger depletions (to -120‰) near 1950 AD, with subsequent rapid enrichment of the atmospheric reservoir of the compound to the present day value. Mass-balance calculations show that this change is likely to have been caused by a large change in the isotopic composition of anthropogenic CFC-12 emissions, probably due to technological advances in the CFC production process over the last 80 yr, though direct evidence is lacking.

  13. Plutonium Mobility Studies: 216-Z-9 Trench Sample Analysis Results

    SciTech Connect

    Cantrell, Kirk J.; Geiszler, Keith N.; Arey, Bruce W.

    2008-09-05

    A variety of analyses were conducted on selected sediment samples collected from two wells (299 W15-46 and 299-W15-48) drilled near the 216-Z-9 Trench to elucidate the form and potential for Pu and Am to be mobilized under present conditions and those that could be expected in future remediation scenarios. Analyses included moisture content, determination of the less than sand size fraction (silt plus clay), carbon analysis, SEM/EDS analysis, microwave-assisted acid digestions for total element analysis, and extraction tests using Hanford groundwater as the leachate. Results of the extraction tests were used as input to conduct equilibrium geochemical modeling of the solutions with Geochemist’s Workbench®. Geochemical modeling results for Pu were evaluated in terms of recent conclusions regarding the solubility and redox reactions of Pu by Neck et al. (2007a, 2007b). It was found that the highest concentrations of Pu and Am were associated with sediments of low silt/clay content and occur above silt/clay rich layers within the sediment profile. It was also found that the Pu and Am were relatively enriched in the silt/clay portion of these samples. The fact that the highest concentrations of Pu and Am occurred in sediments with low silt/clay contents suggests that waste solutions had perched on top of the low permeability silt/clay rich layers and interactions with the high silt/clay layers was minimal. SEM/EDS analysis indicated that the Pu and Am in these sediments does not occur as discrete micron size particles, and therefore must occur as mononuclear or polynuclear/ nanoclusters size particles adsorbed throughout the sediment samples. Leaching of these samples with Hanford groundwater indicates that release of Pu and Am from the sediments is correlated most significantly with the acidity of the water and not the initial concentrations of Pu and Am in the sediments. Only extracts that were acidic after contact with the sediments (pH 4.3 to 5.4) contained

  14. Rheology and TIC/TOC results of ORNL tank samples

    SciTech Connect

    Pareizs, J. M.; Hansen, E. K.

    2013-04-26

    The Savannah River National Laboratory (SRNL)) was requested by Oak Ridge National Laboratory (ORNL) to perform total inorganic carbon (TIC), total organic carbon (TOC), and rheological measurements for several Oak Ridge tank samples. As received slurry samples were diluted and submitted to SRNL-Analytical for TIC and TOC analyses. Settled solids yield stress (also known as settled shear strength) of the as received settled sludge samples were determined using the vane method and these measurements were obtained 24 hours after the samples were allowed to settled undisturbed. Rheological or flow properties (Bingham Plastic viscosity and Bingham Plastic yield stress) were determined from flow curves of the homogenized or well mixed samples. Other targeted total suspended solids (TSS) concentrations samples were also analyzed for flow properties and these samples were obtained by diluting the as-received sample with de-ionized (DI) water.

  15. Estimation of sampling error uncertainties in observed surface air temperature change in China

    NASA Astrophysics Data System (ADS)

    Hua, Wei; Shen, Samuel S. P.; Weithmann, Alexander; Wang, Huijun

    2016-06-01

    This study examines the sampling error uncertainties in the monthly surface air temperature (SAT) change in China over recent decades, focusing on the uncertainties of gridded data, national averages, and linear trends. Results indicate that large sampling error variances appear at the station-sparse area of northern and western China with the maximum value exceeding 2.0 K2 while small sampling error variances are found at the station-dense area of southern and eastern China with most grid values being less than 0.05 K2. In general, the negative temperature existed in each month prior to the 1980s, and a warming in temperature began thereafter, which accelerated in the early and mid-1990s. The increasing trend in the SAT series was observed for each month of the year with the largest temperature increase and highest uncertainty of 0.51 ± 0.29 K (10 year)-1 occurring in February and the weakest trend and smallest uncertainty of 0.13 ± 0.07 K (10 year)-1 in August. The sampling error uncertainties in the national average annual mean SAT series are not sufficiently large to alter the conclusion of the persistent warming in China. In addition, the sampling error uncertainties in the SAT series show a clear variation compared with other uncertainty estimation methods, which is a plausible reason for the inconsistent variations between our estimate and other studies during this period.

  16. [Problems in sampling the polycyclic aromatic hydrocarbons and air-dispersed particles].

    PubMed

    Pozzoli, L; Cottica, D

    1984-01-01

    Polynuclear aromatic hydrocarbons (PAH) are difficult to monitor and quantify. This study has been worked-out to evaluate various sampling methods for monitoring PAH in the work environment: the sampling devices were tested on the field in a carbon electrodes factory. During the field surveys we used the following sampling procedures that actually are the most adopted: Glass fiber filter, Silver membrane (Teflon, cellulosic esters), The over mentioned membrane filters followed by solid substrate (Amberlite XAD-2). For the analytical quantification we followed this procedure: PAH s extraction from membranes and resins by solvent in ultrasonic bath; quantification by GS-MS (single ion monitor, capillary column, on column injection). Results of field testing show that for completely retain PAHs during air sampling in work environment it is necessary to use a membrane filter followed by a back-up tube of Amberlite-XAD-2 resin: the use of this sampling device is particularly recommended during monitoring of work operations with temperature greater than or equal to 150 degrees C involving coke oven procedure, charcoal production, asphalt production, petroleum coking operations.

  17. First results from the oil sands passive air monitoring network for polycyclic aromatic compounds.

    PubMed

    Schuster, Jasmin K; Harner, Tom; Su, Ky; Mihele, Cristian; Eng, Anita

    2015-03-01

    Results are reported from an ongoing passive air monitoring study for polycyclic aromatic compounds (PACs) in the Athabasca oil sands region in Alberta, Canada. Polyurethane foam (PUF) disk passive air samplers were deployed for consecutive 2-month periods from November 2010 to June 2012 at 17 sites. Samples were analyzed for polycyclic aromatic hydrocarbons (PAHs), alkylated PAHs, dibenzothiophene and its alkylated derivatives (DBTs). Relative to parent PAHs, alkylated PAHs and DBTs are enriched in bitumen and therefore considered to be petrogenic markers. Concentrations in air were in the range 0.03-210 ng/m(3), 0.15-230 ng/m(3) and 0.01-61 ng/m(3) for ∑PAHs, ∑alkylated PAHs and ΣDBTs, respectively. An exponential decline of the PAC concentrations in air with distance from mining areas and related petrogenic sources was observed. The most significant exponential declines were for the alkylated PAHs and DBTs and attributed to their association with mining-related emissions and near-source deposition, due to their lower volatility and greater association with depositing particles. Seasonal trends in concentrations in air for PACs were not observed for any of the compound classes. However, a forest fire episode during April to July 2011 resulted in greatly elevated PAH levels at all passive sampling locations. Alkylated PAHs and DBTs were not elevated during the forest fire period, supporting their association with petrogenic sources. Based on the results of this study, an "Athabasca PAC profile" is proposed as a potential source marker for the oil sands region. The profile is characterized by ∑PAHs/∑Alkylated PAHs = ∼0.2 and ∑PAHs/∑DBTs = ∼5.

  18. HESTIA Phase I Test Results: The Air Revitalization System

    NASA Technical Reports Server (NTRS)

    Wright, Sarah E.; Hansen, Scott W.

    2016-01-01

    In any human spaceflight mission, a number of Environmental Control & Life Support System (ECLSS) technologies work together to provide the conditions astronauts need to live healthily, productively, and comfortably in space. In a long-duration mission, many of these ECLSS technologies may use materials supplied by In-Situ Resource Utilization (ISRU), introducing more interactions between systems. The Human Exploration Spacecraft Test-bed for Integration & Advancement (HESTIA) Project aims to create a test-bed to evaluate ECLSS and ISRU technologies and how they interact in a high-fidelity, closed-loop, human-rated analog habitat. Air purity and conditioning are essential components within any ECLSS and for HESTIA's first test they were achieved with the Air Revitalization System (ARS) described below. The ARS provided four essential functions to the test-bed chamber: cooling the air, removing humidity from the air, removing trace contaminants, and scrubbing carbon dioxide (CO2) from the air. In this case, the oxygen supply function was provided by ISRU. In the current configuration, the ARS is a collection of different subsystems. A fan circulates the air, while a condensing heat exchanger (CHX) pulls humidity out of the air. A Trace Contaminant Removal System (TCRS) filters the air of potentially harmful contaminants. Lastly, a Reactive Plastic Lithium Hydroxide (RP-LiOH) unit removes CO2 from the breathing air. During the HESTIA Phase I test in September 2015, the ARS and its individual components each functioned as expected, although further analysis is underway. During the Phase I testing and in prior bench-top tests, the energy balance of heat removed by the CHX was not equal to the cooling it received. This indicated possible instrument error and therefore recalibration of the instruments and follow-up testing is planned in 2016 to address the issue. The ARS was tested in conjunction with two other systems: the Human Metabolic Simulator (HMS) and the

  19. Air sampling of flame retardants based on the use of mixed-bed sorption tubes--a validation study.

    PubMed

    Lazarov, Borislav; Swinnen, Rudi; Spruyt, Maarten; Maes, Frederick; Van Campenhout, Karen; Goelen, Eddy; Covaci, Adrian; Stranger, Marianne

    2015-11-01

    An analytical methodology using automatic thermal desorption and gas chromatography mass spectrometry analysis was optimized and validated for simultaneous determination of a set of components from three different flame retardant chemical classes: polybrominated diphenyl ethers (PBDEs) (PBDE-28, PBDE-47, PBDE-66, PBDE-85, PBDE-99, PBDE-100), organophosphate flame retardants (PFRs) (tributyl phosphate, tripropyl phosphate, tris(2-chloroethyl)phosphate-, tris(1,3-dichloro-2-propyl) phosphate, tris(2-ethylhexyl) phosphate, triphenyl phosphate, tris(2-chloro-1-methylethyl) phosphate and tricresylphosphate), and "novel" brominated flame retardants (NBFRs) (pentabromotoluene, 2,3,4,5,6-pentabromoethylbenzene, (2,3-dibromopropyl) (2,4,6-tribromophenyl) ether, hexabromobenzene, and 2-ethylhexyl 2,3,4,5-tetrabromobenzoate) in air. The methodology is based on low volume active air sampling of gaseous and particulate air fractions on mixed-bed (polydimethylsiloxane (PDMS)/Tenax TA) sorption tubes. The optimized method provides recoveries >88%; a limit of detection in the range of 6-25 pg m(-3) for PBDEs, 6-171 pg m(-3) for PFRs, and 7-41 pg m(-3) for NBFRs; a linearity greater than 0.996; and a repeatability of less than 10% for all studied compounds. The optimized method was compared with a standard method using active air sampling on XAD-2 sorbent material, followed by liquid extraction. On the one hand, the PDMS/Tenax TA method shows comparable results at longer sampling time conditions (e.g., indoor air sampling, personal air sampling). On the other hand, at shorter sampling time conditions (e.g., sampling from emission test chambers), the optimized method detects up to three times higher concentrations and identifies more flame retardant compounds compared to the standard method based on XAD-2 loading.

  20. Climate factors influencing bacterial count in background air samples.

    PubMed

    Harrison, Roy M; Jones, Alan M; Biggins, Peter D E; Pomeroy, Nigel; Cox, Christopher S; Kidd, Stephen P; Hobman, Jon L; Brown, Nigel L; Beswick, Alan

    2005-01-01

    Total (as opposed to culturable) bacterial number counts are reported for four sites in the United Kingdom measured during campaigns over four separate seasons. These are interpreted in relation to simple climatic factors, i.e. temperature, wind speed and wind direction. Temperature has a marked effect at all four sites with data for a rural coastal site conforming best to a simple exponential model. Data for the other rural and urban locations show a baseline similar to that determined at the coastal rural location, but with some very significant positive excursions. The temperature dependence of bacterial number is found to conform to that typical of bacterial growth rates. At the coastal rural location, bacterial numbers normalised for temperature show no dependence on wind speed whilst at the inland sites there is a decrease with increasing wind speed of the form expected for a large area source. Only one site appeared to show a systematic relationship of bacterial concentrations to wind direction that being a site in the suburbs of Birmingham with highest number concentrations observed on a wind sector approaching from the city centre. PCR techniques have been used to identify predominant types of bacteria and results are presented which show that Bacillus was the dominant genus observed at the three inland sites during the winter and summer seasons. Pseudomonas appeared with comparable frequency at certain sites and seasons. There was in general a greater diversity of bacteria at the coastal site than at the inland sites.

  1. Evaluation of physical sampling efficiency for cyclone-based personal bioaerosol samplers in moving air environments.

    PubMed

    Su, Wei-Chung; Tolchinsky, Alexander D; Chen, Bean T; Sigaev, Vladimir I; Cheng, Yung Sung

    2012-09-01

    The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.

  2. A novel Whole Air Sample Profiler (WASP) for the quantification of volatile organic compounds in the boundary layer

    SciTech Connect

    Mak, J. E.; Su, L.; Guenther, Alex B.; Karl, Thomas G.

    2013-10-16

    The emission and fate of reactive VOCs is of inherent interest to those studying chemical biosphere-atmosphere interactions. In-canopy VOC observations are obtainable using tower-based samplers, but the lack of suitable sampling systems for the full boundary 5 layer has limited the data characterizing the vertical structure of such gases above the canopy height and still in the boundary layer. This is the important region where many reactive VOCs are oxidized or otherwise removed. Here we describe an airborne sampling system designed to collect a vertical profile of air into a 3/800 OD tube 150m in length. The inlet ram air pressure is used to flow sampled air through the 10 tube, which results in a varying flow rate based on aircraft speed and altitude. Since aircraft velocity decreases during ascent, it is necessary to account for the variable flow rate into the tube. This is accomplished using a reference gas that is pulsed into the air stream so that the precise altitude of the collected air can be reconstructed post-collection. The pulsed injections are also used to determine any significant effect 15 from diffusion/mixing within the sampling tube, either during collection or subsequent extraction for gas analysis. This system has been successfully deployed, and we show some measured vertical profiles of isoprene and its oxidation products methacrolein and methyl vinyl ketone from a mixed canopy near Columbia, Missouri.

  3. Report on sampling and analysis of ambient air at the central waste complex

    SciTech Connect

    Stauffer, M., Fluor Daniel Hanford

    1997-02-13

    Over 160 ambient indoor air samples were collected from warehouses at the Central Waste Complex used for the storage of low- level radioactive and mixed wastes. These grab (SUMMA) samples were analyzed by gas chromatography-mass spectrometry using a modified EPA TO-14 procedure. The data from this survey suggest that several buildings had elevated concentrations of volatile organic compounds.

  4. Marine Technician's Handbook, Instructions for Taking Air Samples on Board Ship: Carbon Dioxide Project.

    ERIC Educational Resources Information Center

    Keeling, Charles D.

    This booklet is one of a series intended to provide explicit instructions for the collection of oceanographic data and samples at sea. The methods and procedures described have been used by the Scripps Institution of Oceanography and found reliable and up-to-date. Instructions are given for taking air samples on board ship to determine the…

  5. EVALUATION OF THE FILTER PACK FOR LONG-DURATION SAMPLING OF AMBIENT AIR

    EPA Science Inventory

    A 14-week filter pack (FP) sampler evaluation field study was conducted at a site near Bondville, IL to investigate the impact of weekly sampling duration. Simultaneous samples were collected using collocated filter packs (FP) from two independent air quality monitoring networks...

  6. Development of a multicopter-carried whole air sampling apparatus and its applications in environmental studies.

    PubMed

    Chang, Chih-Chung; Wang, Jia-Lin; Chang, Chih-Yuan; Liang, Mao-Chang; Lin, Ming-Ren

    2016-02-01

    To advance the capabilities of probing chemical composition aloft, we designed a lightweight remote-controlled whole air sampling component (WASC) and integrated it into a multicopter drone with agile maneuverability to perform aerial whole air sampling. A field mission hovering over an exhaust shaft of a roadway tunnel to collect air samples was performed to demonstrate the applicability of the multicopter-carried WASC apparatus. Ten aerial air samples surrounding the shaft vent were collected by the multicopter-carried WASC. Additional five samples were collected manually inside the shaft for comparison. These samples were then analyzed in the laboratory for the chemical composition of 109 volatile organic compounds (VOCs), CH4, CO, CO2, or CO2 isotopologues. Most of the VOCs in the upwind samples (the least affected by shaft exhaust) were low in concentrations (5.9 ppbv for total 109 VOCs), posting a strong contrast to those in the shaft exhaust (235.8 ppbv for total 109 VOCs). By comparing the aerial samples with the in-shaft samples for chemical compositions, the influence of the shaft exhaust on the surrounding natural air was estimated. Through the aerial measurements, three major advantages of the multicopter-carried WASC were demonstrated: 1. The highly maneuverable multicopter-carried WASC can be readily deployed for three-dimensional environmental studies at a local scale (0-1.5 km); 2. Aerial sampling with superior sample integrity and preservation conditions can now be performed with ease; and 3. Data with spatial resolution for a large array of gaseous species with high precision can be easily obtained. PMID:26386435

  7. Development of a multicopter-carried whole air sampling apparatus and its applications in environmental studies.

    PubMed

    Chang, Chih-Chung; Wang, Jia-Lin; Chang, Chih-Yuan; Liang, Mao-Chang; Lin, Ming-Ren

    2016-02-01

    To advance the capabilities of probing chemical composition aloft, we designed a lightweight remote-controlled whole air sampling component (WASC) and integrated it into a multicopter drone with agile maneuverability to perform aerial whole air sampling. A field mission hovering over an exhaust shaft of a roadway tunnel to collect air samples was performed to demonstrate the applicability of the multicopter-carried WASC apparatus. Ten aerial air samples surrounding the shaft vent were collected by the multicopter-carried WASC. Additional five samples were collected manually inside the shaft for comparison. These samples were then analyzed in the laboratory for the chemical composition of 109 volatile organic compounds (VOCs), CH4, CO, CO2, or CO2 isotopologues. Most of the VOCs in the upwind samples (the least affected by shaft exhaust) were low in concentrations (5.9 ppbv for total 109 VOCs), posting a strong contrast to those in the shaft exhaust (235.8 ppbv for total 109 VOCs). By comparing the aerial samples with the in-shaft samples for chemical compositions, the influence of the shaft exhaust on the surrounding natural air was estimated. Through the aerial measurements, three major advantages of the multicopter-carried WASC were demonstrated: 1. The highly maneuverable multicopter-carried WASC can be readily deployed for three-dimensional environmental studies at a local scale (0-1.5 km); 2. Aerial sampling with superior sample integrity and preservation conditions can now be performed with ease; and 3. Data with spatial resolution for a large array of gaseous species with high precision can be easily obtained.

  8. Use of Whole-Genome Sequencing to Link Burkholderia pseudomallei from Air Sampling to Mediastinal Melioidosis, Australia

    PubMed Central

    Price, Erin P.; Mayo, Mark; Kaestli, Mirjam; Theobald, Vanessa; Harrington, Ian; Harrington, Glenda; Sarovich, Derek S.

    2015-01-01

    The frequency with which melioidosis results from inhalation rather than percutaneous inoculation or ingestion is unknown. We recovered Burkholderia pseudomallei from air samples at the residence of a patient with presumptive inhalational melioidosis and used whole-genome sequencing to link the environmental bacteria to B. pseudomallei recovered from the patient. PMID:26488732

  9. Gas-particle partitioning of PCDD/Fs in daily air samples

    NASA Astrophysics Data System (ADS)

    Lohmann, Rainer; Lee, Robert G. M.; Green, Nicholas J. L.; Jones, Kevin C.

    Eight short-term (24-48 h) air samples were taken at Lancaster, UK, to study the gas-particle partitioning of PCDD/Fs. Sampling dates in autumn 1997 were selected with a view to minimising temperature fluctuation during the sampling events. ΣCl 4-8DD/Fs ( ΣTEQ) for the first 6 samples were 1.1-3.6 pg m -3 (15-44 fg TEQ m -3), typical of a rural site; two other samples had ΣCl 4-8DD/Fs of 18 and 7.9 pg m -3, with 320 and 100 fg TEQ m -3. The observed gas-particle distributions varied from 0-34% particle-bound for Cl 2/3DD/Fs to >70% for Cl 6-8DD/Fs. Measured particle-bound fractions were compared to theoretical estimates of their distribution based on the Junge-Pankow model using three different reported sets of vapour pressures. The best correlation was obtained using vapour pressures derived from measured GC-retention time indices ( Eitzer and Hites, 1988). Plotting log partition coefficient ( Kp) versus log sub-cooled liquid vapour pressure ( pL) gave excellent correlations with slopes of roughly -1 for all homologue groups. 2, 3, 7, 8-substituted congeners showed slopes of -1 for the first five sampling events. It is proposed that kinetic factors at the low ambient temperatures, coupled with additional emissions during the last sampling events resulted in non-equilibrium partitioning.

  10. Air pollution "holiday effect" resulting from the Chinese New Year

    NASA Astrophysics Data System (ADS)

    Tan, Pei-Hua; Chou, Chia; Liang, Jing-Yi; Chou, Charles C.-K.; Shiu, Chein-Jung

    Our study was an attempt to conduct a comprehensive and systematical examination of the holiday effect, defined as the difference in air pollutant concentrations between holiday and non-holiday periods. This holiday effect can be applied to other countries with similar national or cultural holidays. Hourly and daily surface measurements of six major air pollutants from thirteen air quality monitoring stations of the Taiwan Environmental Protection Administration during the Chinese New Year (CNY) and non-Chinese New Year (NCNY) periods were used. We documented evidence of a "holiday effect", where air pollutant concentrations were significantly different between holidays (CNY) and non-holidays (NCNY), in the Taipei metropolitan area over the past thirteen years (1994-2006). The concentrations of NO x, CO, NMHC, SO 2 and PM 10 were lower in the CNY than in the NCNY period, while the variation in the concentration of O 3 was reversed, which was mainly due to the NO titration effect. Similar differences in these six air pollutants between the CNY and NCNY periods were also found in the diurnal cycle and in the interannual variation. For the diurnal cycle, a common traffic-related double-peak variation was observed in the NCNY period, but not in the CNY period. Impacts of dust storms were also observed, especially on SO 2 and PM 10 in the CNY period. In the 13-year period of 1994-2006, decreasing trends of NO x and CO in the NCNY period implied a possible reduction of local emissions. Increasing trends of SO 2 and PM 10 in the CNY period, on the other hand, indicated a possible enhancement of long-range transport. These two mechanisms weakened the holiday effect.

  11. Comparison of Grab, Air, and Surface Results for Radiation Site Characterization

    NASA Astrophysics Data System (ADS)

    Glassford, Eric Keith

    2011-12-01

    energy photons from 234Th and 234mPa, the short-lived decay products of 238U, and 235U. Two sided t-tests and coefficient of variation were used to compare sampling types. The large grab samples had the lowest calculated coefficient of variation results for activity and atom percentage. The wipe samples had the highest calculated coefficient of variation of mean specific activity (dis/sec/g) for all three energies. The air filter samples had the highest coefficient of variation calculation for mean atom percentage, for both uranium isotopes examined. The data indicated that the large mass sample was the most effective at characterizing the rolling mill radioactive site conditions, since this would indicate which samples had the smallest variations compared to the mean. Additionally, measurement results of natural uranium in the samples indicate that the distribution of radioactive contamination at the sampling location is most likely non-homogeneous and that the size of the sample collected and analyzed must be sufficiently large to insure that the analytical results are truly representative of the activity present.

  12. Sampling, storage, and analysis of C2-C7 non-methane hydrocarbons from the US National Oceanic and Atmospheric Administration Cooperative Air Sampling Network glass flasks.

    PubMed

    Pollmann, Jan; Helmig, Detlev; Hueber, Jacques; Plass-Dülmer, Christian; Tans, Pieter

    2008-04-25

    An analytical technique was developed to analyze light non-methane hydrocarbons (NMHC), including ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane, n-hexane, isoprene, benzene and toluene from whole air samples collected in 2.5l-glass flasks used by the National Oceanic and Atmospheric Administration, Earth System Research Laboratory, Global Monitoring Division (NOAA ESRL GMD, Boulder, CO, USA) Cooperative Air Sampling Network. This method relies on utilizing the remaining air in these flasks (which is at below-ambient pressure at this stage) after the completion of all routine greenhouse gas measurements from these samples. NMHC in sample aliquots extracted from the flasks were preconcentrated with a custom-made, cryogen-free inlet system and analyzed by gas chromatography (GC) with flame ionization detection (FID). C2-C7 NMHC, depending on their ambient air mixing ratios, could be measured with accuracy and repeatability errors of generally < or =10-20%. Larger deviations were found for ethene and propene. Hexane was systematically overestimated due to a chromatographic co-elution problem. Saturated NMHC showed less than 5% changes in their mixing ratios in glass flask samples that were stored for up to 1 year. In the same experiment ethene and propene increased at approximately 30% yr(-1). A series of blank experiments showed negligible contamination from the sampling process and from storage (<10 pptv yr(-1)) of samples in these glass flasks. Results from flask NMHC analyses were compared to in-situ NMHC measurements at the Global Atmospheric Watch station in Hohenpeissenberg, Germany. This 9-months side-by-side comparison showed good agreement between both methods. More than 94% of all data comparisons for C2-C5 alkanes, isoprene, benzene and toluene fell within the combined accuracy and precision objectives of the World Meteorological Organization Global Atmosphere Watch (WMO-GAW) for NMHC measurements.

  13. Development of an Integrated Suspended Sediment Sampling System - Prototype Results

    NASA Astrophysics Data System (ADS)

    Nerantzaki, Sofia; Moirogiorgou, Konstantia; Efstathiou, Dionissis; Giannakis, George; Voutsadaki, Stella; Zervakis, Michalis; Sibetheros, Ioannis A.; Zacharias, Ierotheos; Karatzas, George P.; Nikolaidis, Nikolaos P.

    2015-04-01

    The Mediterranean region is characterized by a unique micro-climate and a complex geologic and geomorphologic environment caused by its position in the Alpine orogenesis belt. Unique features of the region are the temporary rivers that are dry streams or streams with very low flow for most of the time over decadal time scales. One of their key characteristics is that they present flashy hydrographs with response times ranging from minutes to hours. It is crucial to monitor flash-flood events and observe their behavior since they can cause environmental degradation of the river's wider location area. The majority of sediment load is transferred during these flash events. Quantification of these fluxes through the development of new measuring devices is of outmost importance as it is the first step for a comprehensive understanding of the water quality, the soil erosion and erosion sources, and the sediment and nutrient transport routes. This work proposes an integrated suspended sediment sampling system which is implemented in a complex semi-arid Mediterranean watershed (i.e. the Koiliaris River Basin of Crete) with temporary flow tributaries and karstic springs. The system consists of sensors monitoring water stage and turbidity, an automated suspended sediment sampler, and an online camera recording video sequence of the river flow. Water stage and turbidity are continuously monitored and stage is converted to flow with the use of a rating curve; when either of these variables exceeds certain thresholds, the pump of the sediment sampler initiates sampling with a rotation proportional to the stage (flow weighted sampling). The water passes through a filter that captures the sediment, the solids are weighted after each storm and the data are converted to a total sediment flux. At the same time, the online camera derives optical measurements for the determination of the two-dimensional river flow velocity and the spatial sediment distribution by analyzing the Hue

  14. Comparison of mold concentrations quantified by MSQPCR in indoor and outdoor air sampled simultaneously

    SciTech Connect

    Meklin, Teija; Reponen, Tina; McKinstry, Craig A.; Cho, Seung H.; Grinshpun, Sergey A.; Nevalainen, Aino; Vepsalainen, Asko; Haugland, Richard A.; Lemasters, Grace; Vesper, Sephen J.

    2007-08-15

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of 36 mold species in dust and in indoor and in outdoor air samples that were taken simultaneously in 17 homes in Cincinnati with no-known water damage. The total spore concentrations in the indoor (I) and outdoor (O) air samples were statistically significantly different and the concentrations in the three sample types of many of the individual species were significantly different (p < 0.05 based on the Wilcoxon Signed Rank Test). The I/O ratios of the averages or geometric means of the individual species were generally less than 1; but these I/O ratios were quite variable ranging from 0.03 for A. sydowii to 1.2 for Acremonium strictum. There were no significant correlations for the 36 specific mold concentrations between the dust samples and the indoor or outdoor air samples (based on the Spearman’s Rho test). The indoor and outdoor air concentrations of 32 of the species were not correlated. Only Aspergillus penicillioides, C. cladosporioides types 1 and 2 and C. herbarum had sufficient data to estimate a correlation at rho > 0.5 with signicance (p < 0.05) In six of these homes, a previous dust sample had been collected and analyzed 2 years earlier. The ERMI© values for the dust samples taken in the same home two years apart were not significantly different (p=0.22) based on Wilcoxon Signed Rank Test.

  15. Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.; Pekour, Mikhail S.

    2014-12-02

    The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer

  16. Comparison of the multiple-sample means with composite sample results for fecal indicator bacteria by quantitative PCR and culture.

    PubMed

    Converse, Reagan R; Wymer, Larry J; Dufour, Alfred P; Wade, Timothy J

    2012-10-01

    Few studies have addressed the efficacy of composite sampling for measuring indicator bacteria by quantitative PCR (qPCR). We compared results from composited samples with multiple-sample means for culture- and qPCR-based water quality monitoring. Results from composited samples for both methods were similarly correlated to multiple-sample means and predicted criteria exceedances equally.

  17. Air sampling for hepatitis B surface antigen in a dental operatory.

    PubMed

    Petersen, N J; Bond, W W; Favero, M S

    1979-09-01

    Forty samples of air with a mean sample volume of 104 liters were collected during the treatment of patients whose blood was positive for HBsAG: no samples contained HBsAG and occult blood. These findings suggest that, if environmentally mediated transmission of hepatitis B occurs in the dental operatory, it is more likely to occur through contact with contaminated surfaces than through the airborne route.

  18. Retained Gas Sampling Results for the Flammable Gas Program

    SciTech Connect

    J.M. Bates; L.A. Mahoney; M.E. Dahl; Z.I. Antoniak

    1999-11-18

    The key phenomena of the Flammable Gas Safety Issue are generation of the gas mixture, the modes of gas retention, and the mechanisms causing release of the gas. An understanding of the mechanisms of these processes is required for final resolution of the safety issue. Central to understanding is gathering information from such sources as historical records, tank sampling data, tank process data (temperatures, ventilation rates, etc.), and laboratory evaluations conducted on tank waste samples.

  19. Sample results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H qualification samples

    SciTech Connect

    Peters, T. B.; Washington, II, A. L.

    2015-01-13

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub-Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

  20. Sample Results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H Qualification Samples

    SciTech Connect

    Peters, T. B.; Washington, A. L.

    2015-01-01

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub- Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

  1. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings. PMID:27569522

  2. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.

  3. Results For The First Quarter 2012 Tank 50 WAC Slurry Sample: Chemical And Radionuclide Contaminant Results

    SciTech Connect

    Bannochie, C. J.

    2012-07-16

    This report details the chemical and radionuclide contaminant results for the characterization of the 2012 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this memorandum: The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted; The reported detection limit for {sup 94}Nb is above the requested limit but below the estimated limit; {sup 247}Cm and {sup 249}Cf are above the requested limits. However, they are below the limits established; The reported detection limit for Norpar 13 is greater than the limit from the WAC; The reported detection limit for Isopar L is greater than the limit from WAC; Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples; The values reported in this report are the concentrations in the sub-sample as detected by the instrument, however, the results may not accurately represent the concentrations of the analytes in Tank 50; The low insoluble solids content increases the measurement uncertainty for insoluble species.

  4. Preliminary results for LDEF/HEPP thermal control samples

    NASA Technical Reports Server (NTRS)

    Kauder, Lon

    1991-01-01

    Sixty-five one inch by twelve inch strips of Kapton coated with various black paints, clear coatings, and thin film oxides were placed at three locations on the Long Duration Exposure Facility. Two sets were flown in the ram direction on top of the MLI blanket of the Cascade Variable Conductance Heat Pipe Experiment. Two other sets were flown on top of the MLI blanket of the Low Temperature Heat Pipe Experiment perpendicular to the ram direction. The last thirteen samples were taped to the perimeter of the HEPP power tray on the space end of the satellite. The solar absorptance and normal emittance measurements made on the 52 remaining samples are presented, as well as data on the above mentioned samples.

  5. RESULTS FOR THE FOURTH QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M

    2011-02-22

    This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limits for {sup 94}Nb, {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. However, they are below the limits established in Reference 3. (3) There is an estimated concentration of trimethylbenzene (2.25 mg/L). This is not a WAC analyte, but it is the first time this organic compound has been detected in a quarterly WAC sample from Tank 50. (4) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC. (5) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

  6. RESULTS FOR THE SECOND QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M.; Bibler, N.

    2010-08-04

    This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Second Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC).1 Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limits for {sup 94}Nb and {sup 144}Ce are above both the established and requested limits from References 4 and 6. (3) The reported detection limits for {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 6. (4) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (5) A measurable concentration of Norpar 13 is present in the sample. The reported concentration is greater than the requested limit from Table 4 and Attachment 8.2 of the WAC. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50. (7) The detection limit for isopropanol has been lowered from 0.5 mg/L to 0.25 mg/L{sup 7}. This revised limit now satisfies the limit in Table 4 of the WAC.

  7. NASA Air Force Cost Model (NAFCOM): Capabilities and Results

    NASA Technical Reports Server (NTRS)

    McAfee, Julie; Culver, George; Naderi, Mahmoud

    2011-01-01

    NAFCOM is a parametric estimating tool for space hardware. Uses cost estimating relationships (CERs) which correlate historical costs to mission characteristics to predict new project costs. It is based on historical NASA and Air Force space projects. It is intended to be used in the very early phases of a development project. NAFCOM can be used at the subsystem or component levels and estimates development and production costs. NAFCOM is applicable to various types of missions (crewed spacecraft, uncrewed spacecraft, and launch vehicles). There are two versions of the model: a government version that is restricted and a contractor releasable version.

  8. Sample results from the interim salt disposition program macrobatch 9 tank 21H qualification samples

    SciTech Connect

    Peters, T. B.

    2015-11-01

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). This document reports characterization data on the samples of Tank 21H.

  9. RESULTS OF ANALYTICAL SAMPLE CROSSCHECKS FOR NEXT GENERATION SOLVENT EXTRACTION SAMPLES ISOPAR L CONCENTRATION AND PH

    SciTech Connect

    Peters, T.; Fink, S.

    2011-09-29

    As part of the implementation process for the Next Generation Cesium Extraction Solvent (NGCS), SRNL and F/H Lab performed a series of analytical cross-checks to ensure that the components in the NGCS solvent system do not constitute an undue analytical challenge. For measurement of entrained Isopar{reg_sign} L in aqueous solutions, both labs performed similarly with results more reliable at higher concentrations (near 50 mg/L). Low bias occurred in both labs, as seen previously for comparable blind studies for the baseline solvent system. SRNL recommends consideration to use of Teflon{trademark} caps on all sample containers used for this purpose. For pH measurements, the labs showed reasonable agreement but considerable positive bias for dilute boric acid solutions. SRNL recommends consideration of using an alternate analytical method for qualification of boric acid concentrations.

  10. Reliability Sampling Plans: A Review and Some New Results

    ERIC Educational Resources Information Center

    Isaic-Maniu, Alexandru; Voda, Viorel Gh.

    2009-01-01

    In this work we present a large area of aspects related to the problem of sampling inspection in the case of reliability. First we discuss the actual status of this domain, mentioning the newest approaches (from a technical view point) such as HALT and HASS and the statistical perspective. After a brief description of the general procedure in…

  11. Adolescent Psychopathy and the Big Five: Results from Two Samples

    ERIC Educational Resources Information Center

    Lynam, Donald R.; Caspi, Avshalom; Moffitt, Terrie E.; Raine, Adrian; Loeber, Rolf; Stouthamer-Loeber, Magda

    2005-01-01

    The present study examines the relation between psychopathy and the Big Five dimensions of personality in two samples of adolescents. Specifically, the study tests the hypothesis that the aspect of psychopathy representing selfishness, callousness, and interpersonal manipulation (Factor 1) is most strongly associated with low Agreeableness,…

  12. XAFS SPECTROSCOPY RESULTS FOR PM SAMPLES FROM RESIDUAL FUEL OIL

    EPA Science Inventory

    X-ray absorption fine structure (XAFS spectroscopy data were obtained from particulate samples produced by the combustion of residual fuel oil in a 732-kW fire-tube boiler at EPA's National Risk Management Research Laboratory in North Carolina. Residual oil flyash (ROFA) from fo...

  13. Evaluation of sampling and analytical methods for the determination of chlorodifluoromethane in air.

    PubMed

    Seymour, M J; Lucas, M F

    1993-05-01

    In January 1989, the Occupational Safety and Health Administration (OSHA) published revised permissible exposure limits (PELs) for 212 compounds and established PELs for 164 additional compounds. In cases where regulated compounds did not have specific sampling and analytical methods, methods were suggested by OSHA. The National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods (NMAM) Method 1020, which was developed for 1,1,2-trichloro-1,2,2-trifluoroethane, was suggested by OSHA for the determination of chlorodifluoromethane in workplace air. Because this method was developed for a liquid and chlorodifluoromethane is a gas, the ability of NMAM Method 1020 to adequately sample and quantitate chlorodifluoromethane was questioned and tested by researchers at NIOSH. The evaluation of NMAM Method 1020 for chlorodifluoromethane showed that the capacity of the 100/50-mg charcoal sorbent bed was limited, the standard preparation procedure was incorrect for a gas analyte, and the analyte had low solubility in carbon disulfide. NMAM Method 1018 for dichlorodifluoromethane uses two coconut-shell charcoal tubes in series, a 400/200-mg tube followed by a 100/50-mg tube, which are desorbed with methylene chloride. This method was evaluated for chlorodifluoromethane. Test atmospheres, with chlorodifluoromethane concentrations from 0.5-2 times the PEL were generated. Modifications of NMAM Method 1018 included changes in the standard preparation procedure, and the gas chromatograph was equipped with a capillary column. These revisions to NMAM 1018 resulted in a 96.5% recovery and a total precision for the method of 7.1% for chlorodifluoromethane. No significant bias in the method was found. Results indicate that the revised NMAM Method 1018 is suitable for the determination of chlorodifluoromethane in workplace air.

  14. Air-spore in Cartagena, Spain: viable and non-viable sampling methods.

    PubMed

    Elvira-Rendueles, Belen; Moreno, Jose; Garcia-Sanchez, Antonio; Vergara, Nuria; Martinez-Garcia, Maria Jose; Moreno-Grau, Stella

    2013-01-01

    In the presented study the airborne fungal spores of the semiarid city of Cartagena, Spain, are identified and quantified by means of viable or non-viable sampling methods. Airborne fungal samples were collected simultaneously using a filtration method and a pollen and particle sampler based on the Hirst methodology. This information is very useful for elucidating geographical patterns of hay fever and asthma. The qualitative results showed that when the non-viable methodology was employed, Cladosporium, Ustilago, and Alternaria were the most abundant spores identified in the atmosphere of Cartagena, while the viable methodology showed that the most abundant taxa were: Cladosporium, Penicillium, Aspergillus and Alternaria. The quantitative results of airborne fungal spores identified by the Hirst-type air sampler (non-viable method), showed that Deuteromycetes represented 74% of total annual spore counts, Cladosporium being the major component of the fungal spectrum (62.2%), followed by Alternaria (5.3%), and Stemphylium (1.3%). The Basidiomycetes group represented 18.9% of total annual spore counts, Ustilago (7.1%) being the most representative taxon of this group and the second most abundant spore type. Ascomycetes accounted for 6.9%, Nectria (2.3%) being the principal taxon. Oomycetes (0.2%) and Zygomycestes and Myxomycestes (0.06%) were scarce. The prevailing species define our bioaerosol as typical of dry air. The viable methodology was better at identifying small hyaline spores and allowed for the discrimination of the genus of some spore types. However, non-viable methods revealed the richness of fungal types present in the bioaerosol. Thus, the use of both methodologies provides a more comprehensive characterization of the spore profile.

  15. Evaluation of a modified sampling method for molecular analysis of air microflora.

    PubMed

    Lech, T; Ziembinska-Buczynska, A

    2015-04-10

    A serious issue concerning the durability of economically important materials for humans related to cultural heritage is the process of biodeterioration. As a result of this phenomenon, priceless works of art, documents, and old prints have undergone a process of decomposition caused by microorganisms. Therefore, it is important to constantly monitor the presence and diversity of microorganisms in exposition rooms and storage areas of historical objects. In addition, the use of molecular biology tools for conservation studies will enable detailed research as well as reduce the time needed to perform the analyses compared with using conventional methods related to microbiology and conservation. The aim of this study was to adapt the sampling indoor air method for direct DNA extraction from microorganisms, including evaluating the extracted DNA quality and concentration. The obtained DNA was used to study the diversity of mold fungi in indoor air using polymerase chain reaction-denaturing gradient gel electrophoresis in specific archives and museum environments. The research was conducted in 2 storage rooms of the National Archives in Krakow and in 1 exposition room of the Archaeological Museum in Krakow (Poland).

  16. Detection of Mycoplasma hyopneumoniae by Air Sampling with a Nested PCR Assay

    PubMed Central

    Stärk, Katharina D. C.; Nicolet, Jacques; Frey, Joachim

    1998-01-01

    This article describes the first successful detection of airborne Mycoplasma hyopneumoniae under experimental and field conditions with a new nested PCR assay. Air was sampled with polyethersulfone membranes (pore size, 0.2 μm) mounted in filter holders. Filters were processed by dissolution and direct extraction of DNA for PCR analysis. For the PCR, two nested pairs of oligonucleotide primers were designed by using an M. hyopneumoniae-specific DNA sequence of a repeated gene segment. A nested PCR assay was developed and used to analyze samples collected in eight pig houses where respiratory problems had been common. Air was also sampled from a mycoplasma-free herd. The nested PCR was highly specific and 104 times as sensitive as a one-step PCR. Under field conditions, the sampling system was able to detect airborne M. hyopneumoniae on 80% of farms where acute respiratory disease was present. No airborne M. hyopneumoniae was detected on infected farms without acute cases. The chance of successful detection was increased if air was sampled at several locations within a room and at a lower air humidity. PMID:9464391

  17. Risk Gambling and Personality: Results from a Representative Swedish Sample.

    PubMed

    Sundqvist, Kristina; Wennberg, Peter

    2015-12-01

    The association between personality and gambling has been explored previously. However, few studies are based on representative populations. This study aimed at examining the association between risk gambling and personality in a representative Swedish population. A random Swedish sample (N = 19,530) was screened for risk gambling using the Lie/Bet questionnaire. The study sample (N = 257) consisted of those screening positive on Lie/Bet and completing a postal questionnaire about gambling and personality (measured with the NODS-PERC and the HP5i respectively). Risk gambling was positively correlated with Negative Affectivity (a facet of Neuroticism) and Impulsivity (an inversely related facet of Conscientiousness), but all associations were weak. When taking age and gender into account, there were no differences in personality across game preference groups, though preferred game correlated with level of risk gambling. Risk gamblers scored lower than the population norm data with respect to Negative Affectivity, but risk gambling men scored higher on Impulsivity. The association between risk gambling and personality found in previous studies was corroborated in this study using a representative sample. We conclude that risk and problem gamblers should not be treated as a homogeneous group, and prevention and treatment interventions should be adapted according to differences in personality, preferred type of game and the risk potential of the games.

  18. RESULTS FOR THE FIRST QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M.; Bibler, N.

    2010-05-05

    This report details the chemical and radionuclide contaminant results for the characterization of the 2010 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (3) The reported detection limits for {sup 59}Ni and {sup 94}Nb are above the requested limits from Reference 4. However, they are each below the limits established in Reference 6. (4) The reported detection limit for isopropanol is greater than the requested limit from Table 4 of the WAC. (5) The reported detection limits for 247Cm and 249Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 6. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

  19. RESULTS FOR THE FIRST QUARTER 2012 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Bannochie, C.

    2012-06-06

    This report details the chemical and radionuclide contaminant results for the characterization of the 2012 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this memorandum: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section; (2) The reported detection limit for {sup 94}Nb is above the requested limit from Reference 2 but below the estimated limit in Reference 3; (3) {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. however, they are below the limits established in Reference 3; (4) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC; (5) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC; (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples, the values reported in this report are the concentrations in the sub-sample as detected by the instrument; however, the results may not accurately represent the concentrations of the analytes in Tank 50; and (7) The low insoluble solids content increases the measurement uncertainty for insoluble species.

  20. RESULTS FOR THE THIRD QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M.; Bibler, N.

    2010-12-09

    This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (i) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (ii) The reported detection limits for {sup 94}Nb, {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 3. (iii) The reported detection limit for {sup 242m}Am is greater than the requested limit from Attachment 8.4 of the WAC. (iv) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (v) The reported concentration of Isopropanol is greater than the limit from Table 4 of the WAC. (vi) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

  1. Solubility testing of actinides on breathing-zone and area air samples

    SciTech Connect

    Metzger, R.L.; Jessop, B.H.; McDowell, B.L.

    1996-02-01

    A solubility testing method for several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALS{reg_sign}) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of U{sub 3}O{sub 8}. Profiles developed for U{sub 3}O{sub 8} samples show good agreement with in vitro and in vivo tests performed by other investigators on samples from the same uranium mills.

  2. RESULTS FOR THE SECOND QUARTER 2011 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Eibling, R.

    2011-08-25

    The Saltstone Facility is designed and permitted to immobilize and dispose of low-level radioactive and hazardous liquid waste (salt solution) remaining from the processing of radioactive material at the Savannah River Site. Low-level waste (LLW) streams from the Effluent Treatment Project (ETP), H-Canyon, the DDA (Deliquification, Dissolution, and Adjustment) process, and the decontaminated salt solution product from the Actinide Removal Process/Modular Caustic Side Solvent Extraction (CSSX) Unit (ARP/MCU) process are stored in Tank 50 until the LLW can be transferred to the Saltstone Facility for treatment and disposal. The LLW must meet the specified waste acceptance criteria (WAC) before it is processed into saltstone. The specific chemical and radionuclide contaminants and their respective WAC limits are listed in the current Saltstone WAC. Waste Solidification Engineering (WSE) requested that Savannah River National Laboratory (SRNL) perform quarterly analysis on saltstone samples. The concentrations of chemical and radionuclide contaminants are measured to ensure the saltstone produced during each quarter is in compliance with the current WAC. This report documents the concentrations of chemical and radionuclide contaminants for the 2011 Second Quarter samples collected from Tank 50 on April 4, 2011 and discusses those results in further detail than the previously issued results report. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limit for {sup 59}Ni is above the requested limit from Reference 2 but below the established limit in Reference 3. (3) The reported detection limit for {sup 94}Nb is above the requested limit from Reference 2; however, it is below the established limits in Reference 3. (4) The reported concentration of

  3. Evidence for microorganisms in stratosphere air samples collected at a height of 41km

    NASA Astrophysics Data System (ADS)

    Wainwright, Milton; Wickramasinghe, Nalin C.; Narlikar, J. V.; Rajaratnam, P.

    2003-02-01

    Samples of air removed from the stratosphere, at an altitude of 41km, were previously found to contain viable, but non-cultureable bacteria (cocci and rods). Here, we describe experiments aimed at growing these organisms, together with any others, present in the samples. Two bacteria (Bacillus simplex and Staphylococcus pasteuri) and a single fungus, Engyodontium albus (limber)de Hoog were isolated from the samples. Contamination can never be ruled out when space-derived samples are studied on earth, however, we are confident that the organisms isolated here originated from the stratosphere.

  4. Scheduling whole-air samples above the Trade Wind Inversion from SUAS using real-time sensors

    NASA Astrophysics Data System (ADS)

    Freer, J. E.; Greatwood, C.; Thomas, R.; Richardson, T.; Brownlow, R.; Lowry, D.; MacKenzie, A. R.; Nisbet, E. G.

    2015-12-01

    Small Unmanned Air Systems (SUAS) are increasingly being used in science applications for a range of applications. Here we explore their use to schedule the sampling of air masses up to 2.5km above ground using computer controlled bespoked Octocopter platforms. Whole-air sampling is targeted above, within and below the Trade Wind Inversion (TWI). On-board sensors profiled the TWI characteristics in real time on ascent and, hence, guided the altitudes at which samples were taken on descent. The science driver for this research is investigation of the Southern Methane Anomaly and, more broadly, the hemispheric-scale transport of long-lived atmospheric tracers in the remote troposphere. Here we focus on the practical application of SUAS for this purpose. Highlighting the need for mission planning, computer control, onboard sensors and logistics in deploying such technologies for out of line-of-sight applications. We show how such a platform can be deployed successfully, resulting in some 60 sampling flights within a 10 day period. Challenges remain regarding the deployment of such platforms routinely and cost-effectively, particularly regarding training and support. We present some initial results from the methane sampling and its implication for exploring and understanding the Southern Methane Anomaly.

  5. GUIDE TO CALCULATING TRANSPORT EFFICIENCY OF AEROSOLS IN OCCUPATIONAL AIR SAMPLING SYSTEMS

    SciTech Connect

    Hogue, M.; Hadlock, D.; Thompson, M.; Farfan, E.

    2013-11-12

    This report will present hand calculations for transport efficiency based on aspiration efficiency and particle deposition losses. Because the hand calculations become long and tedious, especially for lognormal distributions of aerosols, an R script (R 2011) will be provided for each element examined. Calculations are provided for the most common elements in a remote air sampling system, including a thin-walled probe in ambient air, straight tubing, bends and a sample housing. One popular alternative approach would be to put such calculations in a spreadsheet, a thorough version of which is shared by Paul Baron via the Aerocalc spreadsheet (Baron 2012). To provide greater transparency and to avoid common spreadsheet vulnerabilities to errors (Burns 2012), this report uses R. The particle size is based on the concept of activity median aerodynamic diameter (AMAD). The AMAD is a particle size in an aerosol where fifty percent of the activity in the aerosol is associated with particles of aerodynamic diameter greater than the AMAD. This concept allows for the simplification of transport efficiency calculations where all particles are treated as spheres with the density of water (1g cm-3). In reality, particle densities depend on the actual material involved. Particle geometries can be very complicated. Dynamic shape factors are provided by Hinds (Hinds 1999). Some example factors are: 1.00 for a sphere, 1.08 for a cube, 1.68 for a long cylinder (10 times as long as it is wide), 1.05 to 1.11 for bituminous coal, 1.57 for sand and 1.88 for talc. Revision 1 is made to correct an error in the original version of this report. The particle distributions are based on activity weighting of particles rather than based on the number of particles of each size. Therefore, the mass correction made in the original version is removed from the text and the calculations. Results affected by the change are updated.

  6. Detection of virulent Rhodococcus equi in exhaled air samples from naturally infected foals.

    PubMed

    Muscatello, G; Gilkerson, J R; Browning, G F

    2009-03-01

    Virulent Rhodococcus equi causes pyogranulomatous bronchopneumonia in foals. The route of infection of foals has been considered to be inhalation of aerosolized bacteria from soil that is contaminated with equine feces. Thus, disease caused by R. equi has been regarded as an opportunistic infection of environmental origin and not a contagious disease. In this study, we report the exhalation of virulent R. equi from the respiratory tract of naturally infected foals. A handheld air-monitoring system was used to recover virulent R. equi from the exhaled breath of foals, and the concentration of virulent R. equi organisms in exhaled air was compared to the concentration in environmental air samples taken from the holding pens and lane areas on farms. R. equi strains carrying the vapA gene of the virulence plasmid were detected by using colony blotting and DNA hybridization techniques in cultures of exhaled air from 67% (37/55) of foals tested. The concentration of virulent R. equi organisms in exhaled air from foals was significantly higher than that in environmental air (P<0.001). There were no significant differences in the median concentrations of virulent R. equi bacteria exhaled by clinically healthy or diseased foals. The high concentrations of virulent R. equi bacteria in exhaled air suggested that aerosol transmission between foals is possible and may have a significant impact on the prevalence of R. equi pneumonia on farms. The air sampling technique described is potentially useful as a noninvasive method for the detection and quantification of virulent R. equi in the respiratory tract of foals.

  7. RESULTS FOR THE FOURTH QUARTER 2011 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Bannochie, C.

    2012-01-31

    The Saltstone Facility is designed and permitted to immobilize and dispose of low-level radioactive and hazardous liquid waste (salt solution) remaining from the processing of radioactive material at the Savannah River Site. Low-level waste (LLW) streams from the Effluent Treatment Project (ETP), H-Canyon, and the decontaminated salt solution product from the Actinide Removal Process/Modular Caustic Side Solvent Extraction (CSSX) Unit (ARP/MCU) process are stored in Tank 50 until the LLW can be transferred to the Saltstone Facility for treatment and disposal. The LLW must meet the specified waste acceptance criteria (WAC) before it is processed into saltstone. The specific chemical and radionuclide contaminants and their respective WAC limits are in the current Saltstone WAC. Waste Solidification Engineering (WSE) requested that Savannah River National Laboratory (SRNL) perform quarterly analysis on saltstone samples. The concentrations of chemical and radionuclide contaminants are measured to ensure the saltstone produced during each quarter is in compliance with the current WAC. This report documents the concentrations of chemical and radionuclide contaminants for the 2011 Fourth Quarter samples collected from Tank 50 on October 12, 2011 and discusses those results in further detail than the previously issued results report.

  8. RESULTS FOR THE THIRD QUARTER 2011 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M.

    2011-10-20

    The Saltstone Facility is designed and permitted to immobilize and dispose of low-level radioactive and hazardous liquid waste (salt solution) remaining from the processing of radioactive material at the Savannah River Site. Low-level waste (LLW) streams from the Effluent Treatment Project (ETP), H-Canyon, and the decontaminated salt solution product from the Actinide Removal Process/Modular Caustic Side Solvent Extraction (CSSX) Unit (ARP/MCU) process are stored in Tank 50 until the LLW can be transferred to the Saltstone Facility for treatment and disposal. The LLW must meet the specified waste acceptance criteria (WAC) before it is processed into saltstone. The specific chemical and radionuclide contaminants and their respective WAC limits are in the current Saltstone WAC. Waste Solidification Engineering (WSE) requested that Savannah River National Laboratory (SRNL) perform quarterly analysis on saltstone samples. The concentrations of chemical and radionuclide contaminants are measured to ensure the saltstone produced during each quarter is in compliance with the current WAC. This report documents the concentrations of chemical and radionuclide contaminants for the 2011 Third Quarter samples collected from Tank 50 on July 7, 2011 and discusses those results in further detail than the previously issued results report.

  9. Development and calibration of real-time PCR for quantification of airborne microorganisms in air samples

    NASA Astrophysics Data System (ADS)

    An, Hey Reoun; Mainelis, Gediminas; White, Lori

    This manuscript describes the coupling of bioaerosol collection and the use of real-time PCR (RT-PCR) to quantify the airborne bacteria. The quantity of collected bacteria determined by RT-PCR is compared with conventional quantification techniques, such as culturing, microscopy and airborne microorganism counting by using optical particle counter (OPC). Our data show that an experimental approach used to develop standard curves for use with RT-PCR is critical for accurate sample quantification. Using universal primers we generated 12 different standard curves which were used to quantify model organism Escherichia coli (Migula) Catellani from air samples. Standard curves prepared using a traditional approach, where serially diluted genomic DNA extracted from pure cultured bacteria were used in PCR reaction as a template DNA yielded significant underestimation of sample quantities compared to airborne microorganism concentration as measured by an OPC. The underestimation was especially pronounced when standard curves were built using colony forming units (CFUs). In contrast, the estimate of cell concentration in an air sample by RT-PCR was more accurate (˜60% compared to the airborne microorganism concentration) when the standard curve was built using aerosolized E. coli. The accuracy improved even further (˜100%) when air samples used to build the standard curves were diluted first, then the DNA extracted from each dilution was amplified by the RT-PCR—to mimic the handling of air samples with unknown and possibly low concentration. Therefore, our data show that standard curves used for quantification by RT-PCR needs to be prepared using the same environmental matrix and procedures as handling of the environmental sample in question. Reliance on the standard curves generated with cultured bacterial suspension (a traditional approach) may lead to substantial underestimation of microorganism quantities in environmental samples.

  10. RESULTS FOR THE FIRST QUARTER 2011 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M.

    2011-06-15

    This report details the chemical and radionuclide contaminant results for the characterization of the 2011 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section; (2) The reported detection limit for {sup 59}Ni is above both the requested limits from Reference 2 and the established limits in Reference 3; (3) The reported detection limit for {sup 94}Nb is above the requested limit from Reference 2; however, it is below the established limits in Reference 3. This is a change from previously reported results; (4) The reported concentration of {sup 242m}Am is above the target in Listed in Attachment 8.4 of the Saltstone WAC. This is a change from the previously reported results; (5) {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. However, they are below the limits established in Reference 3; (6) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC; (7) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC; and (8) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the instrument; however, the results may not accurately represent the concentrations of the analytes in Tank

  11. RESULTS FOR THE FOURTH QUARTER TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M.; Bibler, N.

    2010-01-27

    The Saltstone Facility is designed and permitted to immobilize and dispose of low-level radioactive and hazardous liquid waste (salt solution) remaining from the processing of radioactive material at the Savannah River Site. Low-level waste (LLW) streams from the Effluent Treatment Project (ETP), H-Canyon, the DDA (Deliquification, Dissolution, and Adjustment) process, and the decontaminated salt solution product from the Actinide Removal Process/Modular Caustic Side Solvent Extraction (CSSX) Unit (ARP/MCU) process are stored in Tank 50 until the LLW can be transferred to the Saltstone Facility for treatment and disposal. The LLW must meet the specified waste acceptance criteria (WAC) before it is processed into saltstone. The specific chemical and radionuclide contaminants and their respective WAC limits are listed in the current Saltstone WAC. SRS Liquid Waste Operations (LWO) requested that Savannah River National Laboratory (SRNL) perform quarterly analysis on saltstone samples. The concentrations of chemical and radionuclide contaminants are measured to ensure the saltstone produced during each quarter is in compliance with the current WAC. This report documents the concentrations of chemical and radionuclide contaminants for the 2009 Fourth Quarter samples collected from Tank 50 on October 2, 2009 and discusses those results in further detail than the previously issued results report. This report details the chemical and radionuclide contaminant results for the characterization of the 2009 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results

  12. Indoor air sampling for fine particulate matter and black carbon in industrial communities in Pittsburgh.

    PubMed

    Tunno, Brett J; Naumoff Shields, Kyra; Cambal, Leah; Tripathy, Sheila; Holguin, Fernando; Lioy, Paul; Clougherty, Jane E

    2015-12-01

    Impacts of industrial emissions on outdoor air pollution in nearby communities are well-documented. Fewer studies, however, have explored impacts on indoor air quality in these communities. Because persons in northern climates spend a majority of their time indoors, understanding indoor exposures, and the role of outdoor air pollution in shaping such exposures, is a priority issue. Braddock and Clairton, Pennsylvania, industrial communities near Pittsburgh, are home to an active steel mill and coke works, respectively, and the population experiences elevated rates of childhood asthma. Twenty-one homes were selected for 1-week indoor sampling for fine particulate matter (PM2.5) and black carbon (BC) during summer 2011 and winter 2012. Multivariate linear regression models were used to examine contributions from both outdoor concentrations and indoor sources. In the models, an outdoor infiltration component explained 10 to 39% of variability in indoor air pollution for PM2.5, and 33 to 42% for BC. For both PM2.5 models and the summer BC model, smoking was a stronger predictor than outdoor pollution, as greater pollutant concentration increases were identified. For winter BC, the model was explained by outdoor pollution and an open windows modifier. In both seasons, indoor concentrations for both PM2.5 and BC were consistently higher than residence-specific outdoor concentration estimates. Mean indoor PM2.5 was higher, on average, during summer (25.8±22.7 μg/m3) than winter (18.9±13.2 μg/m3). Contrary to the study's hypothesis, outdoor concentrations accounted for only little to moderate variability (10 to 42%) in indoor concentrations; a much greater proportion of PM2.5 was explained by cigarette smoking. Outdoor infiltration was a stronger predictor for BC compared to PM2.5, especially in winter. Our results suggest that, even in industrial communities of high outdoor pollution concentrations, indoor activities--particularly cigarette smoking--may play a larger

  13. Indoor air sampling for fine particulate matter and black carbon in industrial communities in Pittsburgh.

    PubMed

    Tunno, Brett J; Naumoff Shields, Kyra; Cambal, Leah; Tripathy, Sheila; Holguin, Fernando; Lioy, Paul; Clougherty, Jane E

    2015-12-01

    Impacts of industrial emissions on outdoor air pollution in nearby communities are well-documented. Fewer studies, however, have explored impacts on indoor air quality in these communities. Because persons in northern climates spend a majority of their time indoors, understanding indoor exposures, and the role of outdoor air pollution in shaping such exposures, is a priority issue. Braddock and Clairton, Pennsylvania, industrial communities near Pittsburgh, are home to an active steel mill and coke works, respectively, and the population experiences elevated rates of childhood asthma. Twenty-one homes were selected for 1-week indoor sampling for fine particulate matter (PM2.5) and black carbon (BC) during summer 2011 and winter 2012. Multivariate linear regression models were used to examine contributions from both outdoor concentrations and indoor sources. In the models, an outdoor infiltration component explained 10 to 39% of variability in indoor air pollution for PM2.5, and 33 to 42% for BC. For both PM2.5 models and the summer BC model, smoking was a stronger predictor than outdoor pollution, as greater pollutant concentration increases were identified. For winter BC, the model was explained by outdoor pollution and an open windows modifier. In both seasons, indoor concentrations for both PM2.5 and BC were consistently higher than residence-specific outdoor concentration estimates. Mean indoor PM2.5 was higher, on average, during summer (25.8±22.7 μg/m3) than winter (18.9±13.2 μg/m3). Contrary to the study's hypothesis, outdoor concentrations accounted for only little to moderate variability (10 to 42%) in indoor concentrations; a much greater proportion of PM2.5 was explained by cigarette smoking. Outdoor infiltration was a stronger predictor for BC compared to PM2.5, especially in winter. Our results suggest that, even in industrial communities of high outdoor pollution concentrations, indoor activities--particularly cigarette smoking--may play a larger

  14. Air and smear sample calculational tool for Fluor Hanford Radiological control

    SciTech Connect

    BAUMANN, B.L.

    2003-09-24

    A spreadsheet calculation tool was developed to automate the calculations performed for determining the concentration of airborne radioactivity and smear counting as outlined in HNF-13536, Section 5.2.7, Analyzing Air and smear Samples. This document reports on the design and testing of the calculation tool.

  15. COMPARISON OF FAST GC/TOFMS WITH METHOD TO-14 FOR ANALYSIS OF AMBIENT AIR SAMPLES

    EPA Science Inventory

    Field studies using portable gas chromatographs (PGC) to analyze volatile organic compounds in ambient air usually include, as reference standard method, the analysis of concurrent, collocated canister samples by EPA Method TO-14. Each laboratory analysis takes about an hour a...

  16. Development of a wireless air pollution sensor package for aerial-sampling of emissions

    EPA Science Inventory

    A new sensor system for mobile and aerial emission sampling was developed for open area pollutant sources, such as prescribed forest burns. The sensor system, termed “Kolibri”, consists of multiple low-cost air quality sensors measuring CO2, CO, samplers for particulate matter wi...

  17. COMPARISON OF MOLD CONCENTRATIONS IN INDOOR AND OUTDOOR AIR SAMPLED SIMULTANEOUSLY AND THEN QUANTIFIED BY MSQPCR

    EPA Science Inventory

    Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 hours in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m3...

  18. Sampling results of the improved SKC diesel particulate matter cassette.

    PubMed

    Noll, James D; Timko, Robert J; McWilliams, Linda; Hall, Peter; Haney, Robert

    2005-01-01

    Diesel particulate matter (DPM) samples from underground metal/nonmetal mines are collected on quartz fiber filters and measured for carbon content using National Institute for Occupational Safety and Health Method 5040. If size-selective samplers are not used to collect DPM in the presence of carbonaceous ore dust, both the ore dust and DPM will collect on the quartz filters, causing the carbon attributed to DPM to be artificially high. Because the DPM particle size is much smaller than that of mechanically generated mine dust aerosols, it can be separated from the larger mine dust aerosol by a single-stage impactor. The SKC DPM cassette is a single-stage impactor designed to collect only DPM aerosols in the presence of carbonaceous mine ore aerosols, which are commonly found in underground nonmetal mines. However, there is limited data on how efficiently the SKC DPM cassette can collect DPM in the presence of ore dust. In this study we investigated the ability of the SKC DPM cassette to collect DPM while segregating ore dust from the sample. We found that the SKC DPM cassette accurately collected DPM. In the presence of carbon-based ore aerosols having an average concentration of 8 mg/m3, no ore dust was detected on SKC DPM cassette filters. We did discover a problem: the surface areas of the DPM deposits on SKC DPM cassettes, manufactured prior to August 2002 were inconsistent. To correct this problem, SKC modified the cassette. The new cassette produced, with 99% confidence, a range of DPM deposit areas between 8.05 and 8.28 cm2, a difference of less than 3%.

  19. Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air

    SciTech Connect

    Harless, R.L.; Lewis, R.G.; McDaniel, D.D.; Gibson, J.F.; Dupuy, A.E.

    1992-01-01

    General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenz-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cubic meter ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C-12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cubic meter and sub-pg/cubic meter levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured.

  20. RESULTS FOR THE FIRST QUARTER 2009 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M.; Diprete, C.; Bibler, N.

    2009-10-06

    This report details the chemical and radionuclide contaminant results for the characterization of the 2009 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the chemical and radioactive contaminants were all less than their respective WAC Targets or Limits except for Am-242m. (2) The radionuclide Am-242m was not detected; however, its detection limit is above the WAC Target given in Attachment 8.4. The higher detection limit was expected based on current analytical capabilities as stated in the Task Technical and Quality Assurance Plan (TTQAP). (3) The reported detection limit of isopropanol was lower than its WAC Limit for accident analysis but higher than its WAC concentration given in Table 4 for vault flammability. The higher detection limit was expected based on current analytical capabilities and is documented in the Task Technical and Quality Assurance Plan (TTQAP). (4) The reported detection limit for Isopar L is lower than its WAC limit for accident analysis in Appendix 8.1 but higher than its WAC concentration given in Table 3 in reference to vault flammability. The higher detection limit was expected based on current analytical capabilities as stated in the Task Technical and Quality Assurance Plan (TTQAP). (5) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately

  1. The potential of a new air cleaner to reduce airborne microorganisms in pig house air: preliminary results.

    PubMed

    Schulz, Jochen; Bao, Endong; Clauss, Marcus; Hartung, Jörg

    2013-01-01

    There is a need for technical solutions to reduce the concentrations of bioaerosols in the air and in the exhaust air of livestock buildings. A prototype of an air washer combined with a UV-irradiation system was positioned in a commercial pig fattening unit to test its efficiency of reducing culturable airborne microorganisms. No significant reduction in airborne bacteria and fungi was observed when untreated air passed through the device. However, when the air washer or the UV-irradiation system was activated, the concentrations of mesophilic aerobic bacteria, methicillin resistant Staphylococcus aureus and mesophilic aerotolerant cocci were reduced significantly (p < 0.01). Washing the air reduced bacteria by 84 to 96% and the relative reduction due to UV-irradiation ranged between 55 and 90%. The highest relative reduction in airborne bacteria (90 to 99%) was detected when the air washer and the UV-irradiation systems were in simultaneous operation. The concentration of total airborne fungi was reduced significantly (p < 0.05) only when the air was washed and UV-irradiated. Although these preliminary results provided significant and comprehensible findings, long-term studies are required to assess the efficiency of the device in more detail.The combination of air washing and UV-irradiation seem to be a useful technique for abating airborne microorganisms within or emitting from piggery buildings. However, some technical problems remain, such as the deposition of particulate matter on the surface of UV-irradiators and the consumption of fresh water by the air washer. These issues must be resolved before the system may be implemented for general practice. PMID:23540197

  2. Isolation of airborne oxacillin-resistant Staphylococcus aureus from culturable air samples of urban residences.

    PubMed

    Perez, Hernando R; Johnson, Rachel; Gurian, Patrick L; Gibbs, Shawn G; Taylor, Jennifer; Burstyn, Igor

    2011-02-01

    Culturable single-stage impactor samples were collected onto nutrient agar in kitchen and bedroom areas of eight urban and four suburban residences in Philadelphia, Pennsylvania. Staphylococcus aureus colonies were identified by replica plating of the original impactor samples onto Chapman Stone medium followed by isolation of up to eight colonies for coagulase testing. Kirby-Bauer disk diffusion method was utilized to evaluate S. aureus resistance to both oxacillin and cefaclor. The median concentrations of total culturable bacteria observed in bedrooms and trash areas were 300 CFU/m(3) and 253 CFU/m(3), respectively. Median culturable Staphylococcus spp. concentrations in bedrooms and trash areas were 142 CFU/m(3) and 204 CFU/m(3), respectively. A total of 148 individual S. aureus colonies were isolated and tested for antibiotic resistance. Cefaclor resistance was encountered among only 6 of the 148 (4%) colonies. Nearly one-quarter of all S. aureus isolates tested displayed resistance (n = 30) or intermediate resistance (n = 5) to oxacillin. Twenty-six percent (n = 20) of trash area isolates and 21% (n = 15) of bedroom isolates displayed resistance or intermediate resistance to oxacillin. The median difference in percent resistance between trash and bedroom areas was 10% (p = 0.1). Results suggest that there may be a systematic difference in bacterial populations between downtown and suburban residences. Storage of household waste and handling of food may contribute to presence of the organism in the air of residences.

  3. Solvent Hold Tank Sample Results For MCU-15-710-711-712: June 2015 Monthly Sample

    SciTech Connect

    Fondeur, F.; Taylor-Pashow, K.

    2015-10-07

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-710, MCU-15-711, and MCU-15-712), pulled on 06/15/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-710-711-712 indicated a low concentration (~ 55 % of nominal) of the suppressor (TiDG) and concentrations of the extractant (MaxCalix), and of the modifier (Cs-7SB) in the solvent that were slightly lower than nominal. This analysis confirms the addition of TiDG, MaxCalix, and modifier (92 % of nominal) to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier were sufficient when this solvent sample was collected from MCU. A higher cesium concentration (9.3 E6 dpm/mL) was observed in this sample relative to recent samples. In the past, this level of cesium appeared to correlate with upsets in the MCU operation. It is not known at this time the reason for the higher cesium level in this solvent. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). In addition, the sample contains up to 10.4 micrograms of mercury per gram of solvent (or 8.7 µg/mL). A relatively large cesium concentration (9.3 E 6 dpm/mL) was measured in this solvent and it may indicate poor cesium stripping. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

  4. Evaluation of the Fourier transform infrared (FTIR) spectrophotometer for analysis of trichloroethylene (TCE) in the presence of freon-113 in carbon disulfide eluates of charcoal air sampling tubes

    SciTech Connect

    Xiao, H.K.; Levine, S.P.; Kinnes, G.; Almaguer, D. )

    1990-07-01

    Results obtained using Fourier transform infrared spectrophotometry (FTIR) for the analysis of samples of carbon disulfide (CS2) eluates containing trichloroethylene (TCE) and freon from charcoal air sampling tubes were evaluated by comparison with results obtained when using gas chromatography (GC). The FTIR yielded accurate results without regard to the presence of freon.

  5. Solvent Hold Tank Sample Results for MCU-15-556-557-558. March 2015 Monthly Sample

    SciTech Connect

    Fondeur, F.; Taylor-Pashow, K.

    2015-05-04

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-556, MCU-15-557, and MCU-15-558), pulled on 03/16/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-556-557-558 indicated a low concentration (~ 78 % of nominal) of the suppressor (TiDG) and concentrations of the extractant (MaxCalix), and of the modifier (CS-7SB) in the solvent that were slightly lower than nominal. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier are sufficient for continuing operation without adding a trim at this time. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). However, the p-nut vials that delivered the samples contained small (1 mm) droplets of oxidized modifier and amides (as detected by the FTIR analysis). In addition, up to 21 microgram of mercury per gram of solvent (or 17.4 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

  6. Analysis of polychlorinated biphenyls in concurrently sampled Chinese air and surface soil.

    PubMed

    Zhang, Zhi; Liu, Liyan; Li, Yi-Fan; Wang, Degao; Jia, Hongliang; Harner, Tom; Sverko, Ed; Wan, Xinnan; Xu, Diandou; Ren, Nanqi; Ma, Jianmin; Pozo, Karla

    2008-09-01

    Polychlorinated biphenyl (PCB) concentrations were measured in a concurrent air and surface soil sampling program across China. Passive air samples were collected for approximately 3 months from mid-July to mid-October, 2005 using polyurethane foam (PUF) disk type samplers at 97 sites and surface soil samples were collected in a subset of 51 sites in the same year. As expected, the air concentrations (pg m(-3)) were highest at urban sites (mean of 350 +/- 218) followed by rural (230 +/- 180) and background sites (77 +/- 50). The PCB homologue composition was similar across China, with no distinction among site types, and reflected the profile of Chinese transformer oil with a greater proportion of lower molecular weight (LMW) congeners, particularly the tri-PCBs. This differs from the profile in Chinese soil that was shifted toward the higher molecular weight (HMW) congeners and likely attributed to numerous years of deposition and accumulation in this reservoir. The PCB profile in surface soil also reflects an "urban fractionation effect" with preferential deposition of HMW congeners near sources. The profile of PCBs in Chinese air was shown to be different than reported for Europe and for the Great Lakes Area (GLA) in North America. European and GLA air samples show a distinction between urban and rural/V background sites, with urban sites dominated by tetra- and penta-PCBs, whereas rural and background sites are shifted toward LMW congeners. European and GLA samples also exhibit much higher PCB concentrations at urban sites. This may be attributed to the use of PCBs in building materials in European and North American cities. In China, the difference between urban and rural/background sites is less pronounced. Strong soil-air correlations were found for the LMW PCBs at the background and rural sites, and for the HMW PCBs at the urban sites, a strong evidence of the urban fractionation effect. To our knowledge, this is the first national-scale study in China

  7. High-throughput liquid-absorption air-sampling apparatus and methods

    DOEpatents

    Zaromb, Solomon

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is <10 cm of water, usually <5 cm of water. The sampler's collection efficiency is usually >20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  8. RESULTS FOR THE THIRD QUARTER 2009 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

    SciTech Connect

    Reigel, M.; Diprete, C.; Bibler, N.

    2009-11-13

    This report details the chemical and radionuclide contaminant results for the characterization of the 2009 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. Recently, a review of the radionuclide inventory in Saltstone Vaults 1 and 4 identified several additional radionuclides, not currently in the WAC, which require quantification ({sup 40}K, {sup 108m}Ag, {sup 133}Ba, {sup 207}Bi, {sup 227}Ac, {sup 228}Ra, {sup 228}Th, {sup 231}Pa, {sup 247}Cm, {sup 249}Cf, {sup 251}Cf). In addition, several of the radionuclides previously reported with minimum detection limits below the requirements listed in the WAC required analysis with reduced detection limits to support future inventory reporting requirements ({sup 22}Na, {sup 26}Al, {sup 59}Ni, {sup 94}Nb, {sup 106}Ru, {sup 144}Ce, {sup 152}Eu, {sup 155}Eu, {sup 226}Ra). This added scope was formally requested in a revision to the standing Technical Task Request for CY2009 Saltstone support and is further discussed in several supporting documents. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants are less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limits for {sup 59}Ni, {sup 94}Nb, {sup 247}Cm, and {sup 249}Cf are above the limits requested by LWO; however, they are below the achievable limits established by Analytical Development (AD). (3) The reported detection limit of isopropanol is lower than its WAC Limit for accident analysis in Appendix 8.1, but higher than its WAC concentration given in

  9. Semiautomatic nondispersive infrared analyzer apparatus for CO/sub 2/ air sample analyses

    SciTech Connect

    Komhyr, W.D.; Waterman, L.S.; Taylor, W.R.

    1983-02-20

    A semiautomatic nondispersive infrared analyzer apparatus has been developed for analysis of up to 50 CO/sub 2/ air samples per day. The samples are collected in 500-ml glass flasks and are transferred to the analyzer with a novel, free-floating piston pump. Sample and calibration gas transfer operations are controlled by a microprocessor, and data are recorded, analyzed, and output by a Hewlett-Packard 9845A/S desktop computer. The apparatus is described, including operating and test modes, and performance characteristics determined from 2 years of operation are given. 7 references, 5 figures, 5 tables.

  10. Solvent Hold Tank Sample Results For MCU-15-750-751-752-: June Monthly Sample

    SciTech Connect

    Fondeur, F.; Taylor-Pashow, K.

    2015-10-07

    Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-750, MCU-15-751, and MCU-15-752), pulled on 06/22/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-750-751-752 indicated a low concentration (~ 49 % of nominal) of the suppressor (TiDG) and slightly lower than nominal concentrations of the extractant (MaxCalix), and of the modifier (Cs-7SB) in the solvent. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier are sufficient for continuing operation without adding a trim at this time but it is recommended that an addition of TiDG, modifier and Isopar™L should be made in the near future. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). In addition, up to 13.9 micrograms of mercury per gram of solvent (or 11.5 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

  11. Volatile organic components of air samples collected from Vertical Launch Missile capsules. Summary report

    SciTech Connect

    Tappan, D.V.; Knight, D.R.; Heyder, E.; Weathersby, P.K.

    1988-09-27

    Gas chromatographic/mass spectroscopic analyses are presented for the volatile organic components found in air samples collected from the inboard vents from Vertical Launch System (VLS) missile capsules aboard a 688 class submarine. Similar analyses were also conducted for a sample of the ship's high pressure air used to fill the missile tubes. A wide variety of organics was detected in the air from the missile capsules; and while no unique components have yet been identified, a significant contribution has been shown to be made by pressure-ventilation of the VLS capsules into the submarine atmosphere which is already heavily laden with volatile organic compounds. The most apparent conclusion from these preliminary analyses is that the mixtures of organic components in the air within VLS missile capsules vary greatly from capsule to capsule (and probably from time to time). Many such samples need to be investigated to provide sufficient information to judge the seriousness of the possibility of venting toxic components into the submarine atmosphere during the maintenance or firing of VLS missiles.

  12. Solvent Hold Tank Sample Results for MCU-15-661-662-663: April 2015 Monthly Sample

    SciTech Connect

    Fondeur, F.; Taylor-Pashow, K.

    2015-07-08

    The Savannah River National Lab (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-661, MCU-15-662, and MCU-15-663 pulled on April 2, 2015) for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-661-662-663 indicated a low concentration (~ 63% of nominal) of the suppressor (TiDG) and a slightly below the nominal concentration (~ 10% below nominal) of the extractant (MaxCalix). The modifier (CS-7SB) level was also 10% below its nominal value while the Isopar™ L level was slightly above its nominal value. This analysis confirms the addition of Isopar™L to the solvent on March 6, 2015. Despite that the values are below target component levels, the current levels of TiDG, CS-7SB and MaxCalix are sufficient for continuing operation without adding a trim at this time until the next monthly sample. No impurities above the 1000 ppm level were found in this solvent. However, the sample was found to contain approximately 18.4 ug/gsolvent mercury. The gamma level increased to 8 E5 dpm/mLsolvent and it represents an order of magnitude increase relative to previous solvent samples. The increase means less cesium is being stripped from the solvent. Further analysis is needed to determine if the recent spike in the gamma measurement is due to external factors such as algae or other material that may impede stripping. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.

  13. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  14. Diffusive sampling and measurement of microbial volatile organic compounds in indoor air.

    PubMed

    Araki, A; Eitaki, Y; Kawai, T; Kanazawa, A; Takeda, M; Kishi, R

    2009-10-01

    Microbial volatile organic compounds (MVOC), chemicals emitted from various microorganisms, in indoor air have been of concern in recent years. For large field studies, diffusive samplers are widely used to measure indoor environments. Since the sampling rate of a sampler is a fundamental parameter to calculate concentration, the sampling rates of eight MVOC with diffusive samplers were determined experimentally using a newly developed water-bubbling method: air was supplied to the MVOC-solutions and the vapor collected in an exposure bag, where diffusive and active samplers were placed in parallel for comparison. Correlations between the diffusive and active samplings gave good linear regressions. The sampling rates were 30-35 ml/min and the detection limits were 0.044-0.178 microg/m(3), as determined by GC/MS analysis. Application of the sampling rates in indoor air was validated by parallel sampling of the diffusive and active sampling method. 5% Propan-2-ol/CS(2) was the best solvent to desorb the compounds from absorbents. The procedure was applied to a field study in 41 dwellings. The most frequently detected compounds were hexan-2-one and heptan-2-one, with 97.5% detection rates and geometric mean values of 0.470 and 0.302 microg/m(3), respectively. This study shows that diffusive samplers are applicable to measure indoor MVOC levels. Practical Implications At present, there are still limited reports on indoor Microbial Volatile Organic Compounds (MVOC) levels in general dwellings and occupants' health. Compared with active sampling methods, air sampling using a diffusive sampler is particularly advantageous for use in large field studies due to its smallness, light-size, easy-handling, and cost-effectiveness. In this study, sampling rates of selected MVOC of the diffusive sampler were determined using the water-bubbling method: generating gases by water-bubbling and exposing the diffusive and active samplers at the same time. The obtained sampling rates

  15. Whole air canister sampling coupled with preconcentration GC/MS analysis of part-per-trillion levels of trimethylsilanol in semiconductor cleanroom air.

    PubMed

    Herrington, Jason S

    2013-08-20

    The costly damage airborne trimethylsilanol (TMS) exacts on optics in the semiconductor industry has resulted in the demand for accurate and reliable methods for measuring TMS at trace levels (i.e., parts per trillion, volume per volume of air [ppt(v)] [~ng/m(3)]). In this study I developed a whole air canister-based approach for field sampling trimethylsilanol in air, as well as a preconcentration gas chromatography/mass spectrometry laboratory method for analysis. The results demonstrate clean canister blanks (0.06 ppt(v) [0.24 ng/m(3)], which is below the detection limit), excellent linearity (a calibration relative response factor relative standard deviation [RSD] of 9.8%) over a wide dynamic mass range (1-100 ppt(v)), recovery/accuracy of 93%, a low selected ion monitoring method detection limit of 0.12 ppt(v) (0.48 ng/m(3)), replicate precision of 6.8% RSD, and stability (84% recovery) out to four days of storage at room temperature. Samples collected at two silicon wafer fabrication facilities ranged from 10.0 to 9120 ppt(v) TMS and appear to be associated with the use of hexamethyldisilazane priming agent. This method will enable semiconductor cleanroom managers to monitor and control for trace levels of trimethylsilanol.

  16. Preliminary Results from a superconducting photocathode sample cavity

    SciTech Connect

    Peter Kneisel; Jacek Sekutowicz; R. Lefferts; A. Lipski

    2005-05-01

    Pure niobium has been proposed as a photocathode material to extract directly photo-currents from the surface of a RF-gun cavity [1]. However, the quantum efficiency of niobium is {approx}3 {center_dot} 10{sup -4}, whereas electro- or vacuum deposited lead has an {approx} 10 times higher quantum efficiency. We have designed and tested a photo-injector niobium cavity, which can be used to insert photo-cathodes made of different materials in the high electric field region of the cavity. Experiments have been conducted with niobium and lead, which show that neither the Q- values of the cavity nor the obtainable surface fields are significantly lowered. This paper reports about the results from these tests.

  17. Changes to indoor air quality as a result of relocating families from slums to public housing

    NASA Astrophysics Data System (ADS)

    Burgos, Soledad; Ruiz, Pablo; Koifman, Rosalina

    2013-05-01

    One largely unstudied benefit of relocating families from slums to public housing is the potential improvement in indoor air quality (IAQ). We compared families that moved from slums to public housing with those that remained living in slums in Santiago, Chile in terms of fine particulate matter (PM2.5) as main indicator of change. A cross-sectional study of 98 relocated families and 71 still living in slums was carried out, obtaining indoor and outdoor samples by a Personal Environmental Monitor. Home characteristics, including indoor air pollution sources were collected through questionnaires. Multivariate regression models included the intervention (public housing or slum), indoor pollution sources, outdoor PM2.5 and family characteristics as predictors. Indoor PM2.5 concentrations were higher in slums (77.8 μg m-3 [SD = 35.7 μg m-3]) than in public housing (55.7 μg m-3 [SD = 34.6 μg m-3], p < 0.001). Differences between indoor and outdoor PM2.5 were significant only in the slum houses. The multivariate analysis showed that housing intervention significantly decreased indoor PM2.5 (10.4 μg m-3) after adjusting by the other predictors. Outdoor PM2.5 was the main predictor of indoor PM2.5. Other significant factors were water heating fuels and indoor smoking. Having infants 1-23 months was associated with a lowering of indoor PM2.5. Our results suggest that a public housing program that moves families from slums to public housing improves indoor air quality directly and also indirectly through air pollution sources.

  18. Thermal Stabilization of Polycubes by Air Oxidation Results of Testing Unirradiated Polystyrene

    SciTech Connect

    BARNEY, G.S.

    2000-05-01

    Polystyrene samples were tested to determine if the polycubes stored at the Plutonium Finishing Plant could be stabilized safely by a thermal air oxidation process using existing production furnaces. Polycubes are compression-molded mixtures of plutonium oxide and/or uranium oxide in a polystyrene matrix. The irradiated polystyrene that forms the matrix of the polycubes will be high and crosslinked because of radiolysis. The behavior of the crosslinked polystyrene used in most of the tests reported here (polystyrene--8% divinyl benzene) appears to imitate polystyrene crosslinked by radiation. This material is more stable toward pyrolysis, is more reactive with oxygen, and produces more carbonaceous char and less flammable gas during oxidation than non-crosslinked polystyrene. The testing showed that air oxidation of polystyrene begins when it is heated to about 200 C in air. The more highly crosslinked polystyrene is oxidized more complete, and at lower temperatures. Pyrolysis is first observed at about 350 C in air and both oxidation and pyrolysis reactions occur simultaneously until about 420 C is reached, where the remaining carbonaceous chnr begins to oxidize. Oxidation is essentially complete in air at about 550 C. The gases evolved in the early stages of heating are mainly oxidation products (water, carbon dioxide, and benzaldehyde). When pyrolysis begins, a mixture of these oxidation products and hydrocarbon pyrolysis products (styrene, benzene, toluene, and indane) are evolved. The char oxidation step yields only carbon dioxide and water. The overall yields of gas were about 87% by weight oxidation products and 13% pyrolysis products. Concentrations of flammable hydrocarbon pyrolysis gases under normal operating conditions are estimated to be less than 5% of the lower Flammability limit. Benzaldehyde concentrations could be as high as 46% of the lower flammability limit, depending on the heating rate and the number of polycubes being processed. These

  19. Air flow assisted ionization for remote sampling of ambient mass spectrometry and its application.

    PubMed

    He, Jiuming; Tang, Fei; Luo, Zhigang; Chen, Yi; Xu, Jing; Zhang, Ruiping; Wang, Xiaohao; Abliz, Zeper

    2011-04-15

    Ambient ionization methods are an important research area in mass spectrometry (MS) analysis. Under ambient conditions, the gas flow and atmospheric pressure significantly affect the transfer and focusing of ions. The design and implementation of air flow assisted ionization (AFAI) as a novel and effective, remote sampling method for ambient mass spectrometry are described herein. AFAI benefits from a high extracting air flow rate. A systematic investigation of the extracting air flow in the AFAI system has been carried out, and it has been demonstrated not only that it plays a role in the effective capture and remote transport of charged droplets, but also that it promotes desolvation and ion formation, and even prevents ion fragmentation during the ionization process. Moreover, the sensitivity of remote sampling ambient MS analysis was improved significantly by the AFAI method. Highly polar and nonpolar molecules, including dyes, pharmaceutical samples, explosives, drugs of abuse, protein and volatile compounds, have been successfully analyzed using AFAI-MS. The successful application of the technique to residue detection on fingers, large object analysis and remote monitoring in real time indicates its potential for the analysis of a variety of samples, especially large objects. The ability to couple this technique with most commercially available MS instruments with an API interface further enhances its broad applicability.

  20. The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs

    PubMed Central

    Capuano, Rosamaria; Santonico, Marco; Pennazza, Giorgio; Ghezzi, Silvia; Martinelli, Eugenio; Roscioni, Claudio; Lucantoni, Gabriele; Galluccio, Giovanni; Paolesse, Roberto; Di Natale, Corrado; D’Amico, Arnaldo

    2015-01-01

    Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath. PMID:26559776

  1. The lung cancer breath signature: a comparative analysis of exhaled breath and air sampled from inside the lungs

    NASA Astrophysics Data System (ADS)

    Capuano, Rosamaria; Santonico, Marco; Pennazza, Giorgio; Ghezzi, Silvia; Martinelli, Eugenio; Roscioni, Claudio; Lucantoni, Gabriele; Galluccio, Giovanni; Paolesse, Roberto; di Natale, Corrado; D'Amico, Arnaldo

    2015-11-01

    Results collected in more than 20 years of studies suggest a relationship between the volatile organic compounds exhaled in breath and lung cancer. However, the origin of these compounds is still not completely elucidated. In spite of the simplistic vision that cancerous tissues in lungs directly emit the volatile metabolites into the airways, some papers point out that metabolites are collected by the blood and then exchanged at the air-blood interface in the lung. To shed light on this subject we performed an experiment collecting both the breath and the air inside both the lungs with a modified bronchoscopic probe. The samples were measured with a gas chromatography-mass spectrometer (GC-MS) and an electronic nose. We found that the diagnostic capability of the electronic nose does not depend on the presence of cancer in the sampled lung, reaching in both cases an above 90% correct classification rate between cancer and non-cancer samples. On the other hand, multivariate analysis of GC-MS achieved a correct classification rate between the two lungs of only 76%. GC-MS analysis of breath and air sampled from the lungs demonstrates a substantial preservation of the VOCs pattern from inside the lung to the exhaled breath.

  2. Comparison of halocarbon measurements in an atmospheric dry whole air sample

    PubMed Central

    Hall, Bradley D.; Harth, Christina M.; Kim, Jin Seog; Lee, Jeongsoon; Montzka, Stephen A.; Mühle, Jens; Reimann, Stefan; Vollmer, Martin K.; Weiss, Ray F.

    2015-01-01

    The growing awareness of climate change/global warming, and continuing concerns regarding stratospheric ozone depletion, will require continued measurements and standards for many compounds, in particular halocarbons that are linked to these issues. In order to track atmospheric mole fractions and assess the impact of policy on emission rates, it is necessary to demonstrate measurement equivalence at the highest levels of accuracy for assigned values of standards. Precise measurements of these species aid in determining small changes in their atmospheric abundance. A common source of standards/scales and/or well-documented agreement of different scales used to calibrate the measurement instrumentation are key to understanding many sets of data reported by researchers. This report describes the results of a comparison study among National Metrology Institutes and atmospheric research laboratories for the chlorofluorocarbons (CFCs) dichlorodifluoromethane (CFC-12), trichlorofluoromethane (CFC-11), and 1,1,2-trichlorotrifluoroethane (CFC-113); the hydrochlorofluorocarbons (HCFCs) chlorodifluoromethane (HCFC-22) and 1-chloro-1,1-difluoroethane (HCFC-142b); and the hydrofluorocarbon (HFC) 1,1,1,2-tetrafluoroethane (HFC-134a), all in a dried whole air sample. The objective of this study is to compare calibration standards/scales and the measurement capabilities of the participants for these halocarbons at trace atmospheric levels. The results of this study show agreement among four independent calibration scales to better than 2.5% in almost all cases, with many of the reported agreements being better than 1.0%. PMID:26753167

  3. Evaluation of a sampling and analysis method for determination of polyhalogenated dibenzo-p-dioxins and dibenzofurans in ambient air

    SciTech Connect

    Harless, R.L.; Lewis, R.G.; McDaniel, D.D.; Gibson, J.F.; Dupuy, A.E.

    1991-01-01

    General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and (13)C12-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hrs to sample 350-400 cu m ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with (13)C12-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from the study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/cu m and sub-pg/cu m levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured. Background levels of these compounds in the ambient air were also determined. Total PCDDs, PCDFs, TBDFs, and PeBDFs were detected in a low concentration range of 0.3 to 3.0 pg/cu m.

  4. Field calibration of rapidly equilibrating thin-film passive air samplers and their potential application for low-volume air sampling studies.

    PubMed

    Farrar, N J; Harner, T J; Sweetman, A J; Jones, K C

    2005-01-01

    This paper reports on a field calibration and ambient deployment study with rapidly equilibrating thin-film passive air samplers. POlymer-coated Glass (POG) samplers have a coating of ethylene vinyl acetate (EVA) less than 1 microm thick coated on to glass, which can be dissolved off after exposure and prepared for quantification of persistent organic pollutants (POPs) that have partitioned into the film during field exposure. In this study, POGs were exposed for up to 18 d, in a study to assess compound uptake rates and their time to approach equilibrium. Results confirmed theoretical predictions, with time to equilibrium varying between a few hours to ca. 20 d for PCB-18 and PCB-138, respectively. Performance reference compounds and contaminated POGs were used to investigate depuration kinetics, confirming that lighter congeners behave extremely dynamically with substantial losses from the films over periods of a few hours. Repeated deployments of the samplers for different3-d periods yielded detectable levels of a range of PCB congeners, which had partitioned from as little as approximately 2 to 10 m3 air. This highlights the potential utility of POGs for extremely sensitive and dynamic passive air sampling in the future to help improve understanding of sources, environmental fate, and behavior of POPs. Recommendations are made for future improvements/refinements in POG sampling and handling procedures.

  5. Sample Results From The Interim Salt Disposition Program Macrobatch 7 Tank 21H Qualification Samples

    SciTech Connect

    Peters, T. B.; Washington, A. L. II

    2013-08-08

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 7 for the Interim Salt Disposition Program (ISDP). An ARP and several ESS tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP/MCU. No issues with the projected Salt Batch 7 strategy are identified, other than the presence of visible quantities of dark colored solids. A demonstration of the monosodium titanate (0.2 g/L) removal of strontium and actinides provided acceptable 4 hour average decontamination factors for Pu and Sr of 3.22 and 18.4, respectively. The Four ESS tests also showed acceptable behavior with distribution ratios (D(Cs)) values of 15.96, 57.1, 58.6, and 65.6 for the MCU, cold blend, hot blend, and Next Generation Solvent (NGS), respectively. The predicted value for the MCU solvent was 13.2. Currently, there are no models that would allow a prediction of extraction behavior for the other three solvents. SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed. While no outstanding issues were noted, the presence of solids in the samples should be investigated in future work. It is possible that the solids may represent a potential reservoir of material (such as potassium) that could have an impact on MCU performance if they were to dissolve back into the feed solution. This salt batch is intended to be the first batch to be processed through MCU entirely using the new NGS-MCU solvent.

  6. Effect of Sampling Depth on Air-Sea CO2 Flux Estimates in River-Stratified Arctic Coastal Waters

    NASA Astrophysics Data System (ADS)

    Miller, L. A.; Papakyriakou, T. N.

    2015-12-01

    In summer-time Arctic coastal waters that are strongly influenced by river run-off, extreme stratification severely limits wind mixing, making it difficult to effectively sample the surface 'mixed layer', which can be as shallow as 1 m, from a ship. During two expeditions in southwestern Hudson Bay, off the Nelson, Hayes, and Churchill River estuaries, we confirmed that sampling depth has a strong impact on estimates of 'surface' pCO2 and calculated air-sea CO2 fluxes. We determined pCO2 in samples collected from 5 m, using a typical underway system on the ship's seawater supply; from the 'surface' rosette bottle, which was generally between 1 and 3 m; and using a niskin bottle deployed at 1 m and just below the surface from a small boat away from the ship. Our samples confirmed that the error in pCO2 derived from typical ship-board versus small-boat sampling at a single station could be nearly 90 μatm, leading to errors in the calculated air-sea CO2 flux of more than 0.1 mmol/(m2s). Attempting to extrapolate such fluxes over the 6,000,000 km2 area of the Arctic shelves would generate an error approaching a gigamol CO2/s. Averaging the station data over a cruise still resulted in an error of nearly 50% in the total flux estimate. Our results have implications not only for the design and execution of expedition-based sampling, but also for placement of in-situ sensors. Particularly in polar waters, sensors are usually deployed on moorings, well below the surface, to avoid damage and destruction from drifting ice. However, to obtain accurate information on air-sea fluxes in these areas, it is necessary to deploy sensors on ice-capable buoys that can position the sensors in true 'surface' waters.

  7. STS-65 Commander Cabana and PLC Hieb take air sample at IML-2 Rack 7 NIZEMI

    NASA Technical Reports Server (NTRS)

    1994-01-01

    STS-65 Commander Robert D. Cabana (right) and Payload Commander (PLC) Richard J. Hieb take an air sample inside the International Microgravity Laboratory 2 (IML-2) spacelab science module. The two crewmembers are in front of Rack 7 which contains the large isothermal furnace (LIF) and slow rotating centrifuge microscope (NIZEMI). The photo was among the first group released by NASA following the two-week IML-2 mission aboard the Space Shuttle Columbia, Orbiter Vehicle (OV) 102.

  8. Air/ground wind shear information integration: Flight test results

    NASA Technical Reports Server (NTRS)

    Hinton, David A.

    1992-01-01

    An element of the NASA/FAA wind shear program is the integration of ground-based microburst information on the flight deck, to support airborne wind shear alerting and microburst avoidance. NASA conducted a wind shear flight test program in the summer of 1991 during which airborne processing of Terminal Doppler Weather Radar (TDWR) data was used to derive microburst alerts. High level microburst products were extracted from TDWR, transmitted to a NASA Boeing 737 in flight via data link, and processed to estimate the wind shear hazard level (F-factor) that would be experienced by the aircraft in the core of each microburst. The microburst location and F-factor were used to derive a situation display and alerts. The situation display was successfully used to maneuver the aircraft for microburst penetrations, during which in situ 'truth' measurements were made. A total of 19 penetrations were made of TDWR-reported microburst locations, resulting in 18 airborne microburst alerts from the TDWR data and two microburst alerts from the airborne in situ measurements. The primary factors affecting alerting performance were spatial offset of the flight path from the region of strongest shear, differences in TDWR measurement altitude and airplane penetration altitude, and variations in microburst outflow profiles. Predicted and measured F-factors agreed well in penetrations near microburst cores. Although improvements in airborne and ground processing of the TDWR measurement would be required to support an airborne executive-level alerting protocol, the feasibility of airborne utilization of TDWR data link data has been demonstrated.

  9. Technical assessment of TRUSAF for compliance with work place air sampling. Revision 1

    SciTech Connect

    Butler, J.D.

    1995-01-23

    The purpose of this Technical Work Document is to satisfy WHC-CM-1-6, the ``WHC Radiological Control Manual.`` This first revision of the original Supporting Document covers the period from January 1, 1994 to December 31, 1994. WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. this document also provides an evaluation of the compliance of the TRUSAF workplace air sampling program to the criteria, standards, and requirements and documents. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  10. Technical assessment of workplace air sampling requirements at tank farm facilities. Revision 1

    SciTech Connect

    Olsen, P.A.

    1994-09-21

    WHC-CM-1-6 is the primary guidance for radiological control at Westinghouse Hanford Company (WHC). It was written to implement DOE N 5480.6 ``US Department of Energy Radiological Control Manual`` as it applies to programs at Hanford which are now overseen by WHC. As such, it complies with Title 10, Part 835 of the Code of Federal Regulations. In addition to WHC-CM-1-6, there is HSRCM-1, the ``Hanford Site Radiological Control Manual`` and several Department of Energy (DOE) Orders, national consensus standards, and reports that provide criteria, standards, and requirements for workplace air sampling programs. This document provides a summary of these, as they apply to WHC facility workplace air sampling programs. This document also provides an evaluation of the compliance of Tank Farms` workplace air sampling program to the criteria, standards, and requirements and documents compliance with the requirements where appropriate. Where necessary, it also indicates changes needed to bring specific locations into compliance.

  11. Measurement of the Tracer Gradient and Sampling System Bias of the Hot Fuel Examination Facility Stack Air Monitoring System

    SciTech Connect

    Glissmeyer, John A.; Flaherty, Julia E.

    2011-07-20

    This report describes tracer gas uniformity and bias measurements made in the exhaust air discharge of the Hot Fuel Examination Facility at Idaho National Laboratory. The measurements were a follow-up on earlier measurements which indicated a lack of mixing of the two ventilation streams being discharged via a common stack. The lack of mixing is detrimental to the accuracy of air emission measurements. The lack of mixing was confirmed in these new measurements. The air sampling probe was found to be out of alignment and that was corrected. The suspected sampling bias in the air sample stream was disproved.

  12. Comparison of the Multiple-sample means with composite sample results for fecal indicator bacteria by quantitative PCR and culture

    EPA Science Inventory

    ABSTRACT: Few studies have addressed the efficacy of composite sampling for measurement of indicator bacteria by QPCR. In this study, composite results were compared to single sample results for culture- and QPCR-based water quality monitoring. Composite results for both methods ...

  13. An approach to area sampling and analysis for total isocyanates in workplace air.

    PubMed

    Key-Schwartz, R J; Tucker, S P

    1999-01-01

    An approach to sampling and analysis for total isocyanates (monomer plus any associated oligomers of a given isocyanate) in workplace air has been developed and evaluated. Based on a method developed by the Occupational Health Laboratory, Ontario Ministry of Labour, Ontario, Canada, isocyanates present in air are derivatized with a fluorescent reagent, tryptamine, in an impinger and subsequently analyzed via high-performance liquid chromatography (HPLC) with fluorescence detection. Excitation and emission wavelengths are set at 275 and 320 nm, respectively. A modification to the Ontario method was made in the replacement of the recommended impinger solvents (acetonitrile and 2,2,4-trimethylpentane) with dimethyl sulfoxide (DMSO). DMSO has the advantages of being compatible with reversedphase HPLC and not evaporating during sampling, as do the more volatile solvents used in the Ontario method. DMSO also may dissolve aerosol particles more efficiently during sampling than relatively nonpolar solvents. Several formulations containing diisocyanate prepolymers have been tested with this method in the laboratory. This method has been issued as National Institute for Occupational Safety and Health (NIOSH) Method 5522 in the first supplement to the fourth edition of the NIOSH Manual of Analytical Methods. This method is recommended for area sampling only due to possible hazards from contact with DMSO solutions containing isocyanate derivatives. The limits of detection are 0.1 microgram/sample for 2,4-toluene diisocyanate, 0.2 microgram/sample for 2,6-toluene diisocyanate, 0.3 microgram/sample for methylene bisphenyl diisocyanate, and 0.2 microgram/sample for 1,6-hexamethylene diisocyanate.

  14. Sorbent-based sampling methods for volatile and semi-volatile organic compounds in air Part 1: Sorbent-based air monitoring options.

    PubMed

    Woolfenden, Elizabeth

    2010-04-16

    Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar) bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents

  15. Ecotoxicological studies of environmental samples from Buenos Aires area using a standardized amphibian embryo toxicity test (AMPHITOX).

    PubMed

    Herkovits, Jorge; Perez-Coll, Cristina; Herkovits, Francisco D

    2002-01-01

    The toxicity of 34 environmental samples from potentially polluted and reference stations were evaluated by means of the AMPHITOX test from acute to chronic exposure according to the toxicity found in each sample. The samples were obtained from surface and ground water, leaches, industrial effluents and soils. The data, expressed in acute, short-term chronic and chronic Toxicity Units (TUa, TUstc and TUc) resulted in a maximal value of 1000 TUc, found in a leach, while the lower toxicity value was 1.4 TUa corresponding to two surface water samples. In five samples (four providing from reference places) no toxicity was detected. The results point out the possibility of evaluating the toxicity of a wide diversity of samples by means of AMPHITOX as a customized toxicity test. The fact that almost all samples with suspected toxicity in rivers and streams from the Metropolitan area of Buenos Aires city resulted toxic, indicates the need of enhanced stewardship of chemical substances for environmental and human health protection purposes. PMID:11808551

  16. Biomimetic air sampling for detection of low concentrations of molecules and bioagents : LDRD 52744 final report.

    SciTech Connect

    Hughes, Robert Clark

    2003-12-01

    Present methods of air sampling for low concentrations of chemicals like explosives and bioagents involve noisy and power hungry collectors with mechanical parts for moving large volumes of air. However there are biological systems that are capable of detecting very low concentrations of molecules with no mechanical moving parts. An example is the silkworm moth antenna which is a highly branched structure where each of 100 branches contains about 200 sensory 'hairs' which have dimensions of 2 microns wide by 100 microns long. The hairs contain about 3000 pores which is where the gas phase molecules enter the aqueous (lymph) phase for detection. Simulations of diffusion of molecules indicate that this 'forest' of hairs is 'designed' to maximize the extraction of the vapor phase molecules. Since typical molecules lose about 4 decades in diffusion constant upon entering the liquid phase, it is important to allow air diffusion to bring the molecule as close to the 'sensor' as possible. The moth acts on concentrations as low as 1000 molecules per cubic cm. (one part in 1e16). A 3-D collection system of these dimensions could be fabricated by micromachining techniques available at Sandia. This LDRD addresses the issues involved with extracting molecules from air onto micromachined structures and then delivering those molecules to microsensors for detection.

  17. Urban air quality assessment using monitoring data of fractionized aerosol samples, chemometrics and meteorological conditions.

    PubMed

    Yotova, Galina I; Tsitouridou, Roxani; Tsakovski, Stefan L; Simeonov, Vasil D

    2016-01-01

    The present article deals with assessment of urban air by using monitoring data for 10 different aerosol fractions (0.015-16 μm) collected at a typical urban site in City of Thessaloniki, Greece. The data set was subject to multivariate statistical analysis (cluster analysis and principal components analysis) and, additionally, to HYSPLIT back trajectory modeling in order to assess in a better way the impact of the weather conditions on the pollution sources identified. A specific element of the study is the effort to clarify the role of outliers in the data set. The reason for the appearance of outliers is strongly related to the atmospheric condition on the particular sampling days leading to enhanced concentration of pollutants (secondary emissions, sea sprays, road and soil dust, combustion processes) especially for ultra fine and coarse particles. It is also shown that three major sources affect the urban air quality of the location studied-sea sprays, mineral dust and anthropogenic influences (agricultural activity, combustion processes, and industrial sources). The level of impact is related to certain extent to the aerosol fraction size. The assessment of the meteorological conditions leads to defining of four downwind patterns affecting the air quality (Pelagic, Western and Central Europe, Eastern and Northeastern Europe and Africa and Southern Europe). Thus, the present study offers a complete urban air assessment taking into account the weather conditions, pollution sources and aerosol fractioning.

  18. Sampling artifacts in active air sampling of semivolatile organic contaminants: Comparing theoretical and measured artifacts and evaluating implications for monitoring networks.

    PubMed

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Klánová, Jana

    2016-10-01

    The effects of sampling artifacts are often not fully considered in the design of air monitoring with active air samplers. Semivolatile organic contaminants (SVOCs) are particularly vulnerable to a range of sampling artifacts because of their wide range of gas-particle partitioning and degradation rates, and these can lead to erroneous measurements of air concentrations and a lack of comparability between sites with different environmental and sampling conditions. This study used specially adapted filter-sorbent sampling trains in three types of active air samplers to investigate breakthrough of SVOCs, and the possibility of other sampling artifacts. Breakthrough volumes were experimentally determined for a range of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in sampling volumes from 300 to 10,000 m(3), and sampling durations of 1-7 days. In parallel, breakthrough was estimated based on theoretical sorbent-vapor pressure relationships. The comparison of measured and theoretical determinations of breakthrough demonstrated good agreement between experimental and estimated breakthrough volumes, and showed that theoretical breakthrough estimates should be used when developing air monitoring protocols. Significant breakthrough in active air samplers occurred for compounds with vapor pressure >0.5 Pa at volumes <700 m(3). Sample volumes between 700 and 10,000 m(3) may lead to breakthrough for compounds with vapor pressures between 0.005 and 0.5 Pa. Breakthrough is largely driven by sample volume and compound volatility (therefore indirectly by temperature) and is independent of sampler type. The presence of significant breakthrough at "typical" sampling conditions is relevant for air monitoring networks, and may lead to under-reporting of more volatile SVOCs.

  19. Results from CrIS/ATMS Obtained Using an AIRS "Version-6 like" Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis; Iredell, Lena

    2015-01-01

    We tested and evaluated Version-6.22 AIRS and Version-6.22 CrIS products on a single day, December 4, 2013, and compared results to those derived using AIRS Version-6. AIRS and CrIS Version-6.22 O3(p) and q(p) products are both superior to those of AIRS Version-6All AIRS and CrIS products agree reasonably well with each other. CrIS Version-6.22 T(p) and q(p) results are slightly poorer than AIRS over land, especially under very cloudy conditions. Both AIRS and CrIS Version-6.22 run now at JPL. Our short term plans are to analyze many common months at JPL in the near future using Version-6.22 or a further improved algorithm to assess the compatibility of AIRS and CrIS monthly mean products and their interannual differences. Updates to the calibration of both CrIS and ATMS are still being finalized. JPL plans, in collaboration with the Goddard DISC, to reprocess all AIRS data using a still to be finalized Version-7 retrieval algorithm, and to reprocess all recalibrated CrISATMS data using Version-7 as well.

  20. Results from CrIS/ATMS Obtained Using an AIRS "Version-6 Like" Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis; Iredell, Lena

    2015-01-01

    We have tested and evaluated Version-6.22 AIRS and Version-6.22 CrIS products on a single day, December 4, 2013, and compared results to those derived using AIRS Version-6. AIRS and CrIS Version-6.22 O3(p) and q(p) products are both superior to those of AIRS Version-6All AIRS and CrIS products agree reasonably well with each other CrIS Version-6.22 T(p) and q(p) results are slightly poorer than AIRS under very cloudy conditions. Both AIRS and CrIS Version-6.22 run now at JPL. Our short term plans are to analyze many common months at JPL in the near future using Version-6.22 or a further improved algorithm to assess the compatibility of AIRS and CrIS monthly mean products and their interannual differencesUpdates to the calibration of both CrIS and ATMS are still being finalized. JPL plans, in collaboration with the Goddard DISC, to reprocess all AIRS data using a still to be finalized Version-7 retrieval algorithm, and to reprocess all recalibrated CrISATMS data using Version-7 as well.

  1. Mass spectrometry of solid samples in open air using combined laser ionization and ambient metastable ionization

    NASA Astrophysics Data System (ADS)

    He, X. N.; Xie, Z. Q.; Gao, Y.; Hu, W.; Guo, L. B.; Jiang, L.; Lu, Y. F.

    2012-01-01

    Mass spectrometry of solid samples in open air was carried out using combined laser ionization and metastable ionization time-of-flight mass spectrometry (LI-MI-TOFMS) in ambient environment for qualitative and semiquantitative (relative analyte information, not absolute information) analysis. Ambient metastable ionization using a direct analysis in realtime (DART) ion source was combined with laser ionization time-of-flight mass spectrometry (LI-TOFMS) to study the effects of combining metastable and laser ionization. A series of metallic samples from the National Institute of Standards and Technology (NIST 494, 495, 498, 499, and 500) and a pure carbon target were characterized using LI-TOFMS in open air. LI-MI-TOFMS was found to be superior to laser-induced breakdown spectroscopy (LIBS). Laser pulse energies between 10 and 200 mJ at the second harmonic (532 nm) of an Nd:YAG laser were applied in the experiment to obtain a high degree of ionization in plasmas. Higher laser pulse energy improves signal intensities of trace elements (such as Fe, Cr, Mn, Ni, Ca, Al, and Ag). Data were analyzed by numerically calculating relative sensitivity coefficients (RSCs) and limit of detections (LODs) from mass spectrometry (MS) and LIBS spectra. Different parameters, such as boiling point, ionization potential, RSC, LOD, and atomic weight, were shown to analyze the ionization and MS detection processes in open air.

  2. Determination of trichloroanisole and trichlorophenol in wineries' ambient air by passive sampling and thermal desorption-gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Camino-Sánchez, F J; Bermúdez-Peinado, R; Zafra-Gómez, A; Ruíz-García, J; Vílchez-Quero, J L

    2015-02-01

    The present paper describes the calibration of selected passive samplers used in the quantitation of trichlorophenol and trichloroanisole in wineries' ambient air, by calculating the corresponding sampling rates. The method is based on passive sampling with sorbent tubes and involves thermal desorption-gas chromatography-triple quadrupole mass spectrometry analysis. Three commercially available sorbents were tested using sampling cartridges with a radial design instead of axial ones. The best results were found for Tenax TA™. Sampling rates (R-values) for the selected sorbents were determined. Passive sampling was also used for accurately determining the amount of compounds present in the air. Adequate correlation coefficients between the mass of the target analytes and exposure time were obtained. The proposed validated method is a useful tool for the early detection of trichloroanisole and its precursor trichlorophenol in wineries' ambient air while avoiding contamination of wine or winery facilities.

  3. Methods for polynuclear aromatic hydrocarbon determination in air samples using polar-bonded phase HPLC and GC-MS with application to oil refinery samples

    SciTech Connect

    Karlesky, K.L.

    1985-01-01

    Particle samples were collected using high volume air samplers fitted with glass fiber filters or with a cascade impactor containing paper filters. They were then cleaned using either extraction with dimethylsulfoxide and pentane or utilizing a small cartridge containing a diamine polar-bonded phase material, the second method being more effective. Vapor phase PAH were sampled using an apparatus designed in the laboratory. After collection, the resins were desorbed with solvent and the PAH content was determined. The suitability of the resins decrease in the following order: Amberlite XAD-2, Chromosorb 105, Tenax GC, coconut charcoal, and Ambesorb XE-348. High performance liquid chromatography (HPLC) was used to determine the behavior of PAH in the normal and reversed phase on polar-bonded phases containing amine, diamine, and pyrrolidone substrates. Results support the proposed mechanism in the normal phase and indicate that both a partitioning and liquid-solid adsorption mechanism takes place in the reversed phase depending upon the mobile phase. Occasionally, these polar-bonded phases can be deactivated by the formation of amine-carbonyl complexes from polar aldehydes or ketones in the solvent or sample. Deactivation can be reversed by flushing with water to hydrolyze the Schiff's base imine back to the amine. Gas chromatography-mass spectroscopy (GC-MS) was used to analyze air samples from oil refineries in Port Arthur, collected over a period of three years. The analytical procedures are applied to the collected samples to determine if they contain detectable amounts of PAH. The GC-MS analysis was adequate for this study but the use of SIM detection is preferred because of the greater sensitivity for PAH.

  4. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    NASA Astrophysics Data System (ADS)

    Khanh Huynh, Cong; Duc, Trinh Vu

    2009-02-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  5. Soyuz 23 Return Samples: Assessment of Air Quality Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    Six mini-grab sample containers (m-GSCs) were returned aboard Soyuz 23 because of concerns that new air pollutants had been present in the air and these were getting into the water recovery system. The Total Organic Carbon Analyzer had been giving increasing readings of total organic carbon (TOC) in the potable water, and it was postulated that an increased load into the system was responsible. The TOC began to decline in late October, 2010. The toxicological assessment of 6 m-GSCs from the ISS is shown in Table 1. The recoveries of 13C-acetone, fluorobenzene, and chlorobenzene from the GSCs averaged 73, 82, and 59%, respectively. We are working to understand the sub-optimal recovery of chlorobenzene.

  6. Relationship of air sampling rates of semipermeable membrane devices with the properties of organochlorine pesticides.

    PubMed

    Zhu, Xiuhua; Ding, Guanghui; Levy, Walkiria; Jakobi, Gert; Schramm, Karl-Werner

    2011-06-01

    The organochlorine pesticides (OCP) in Eastern-Barvaria at Haidel 1160 m a.s.l. were monitored with a low volume active air sampler and semi-permeable membrane devices (SPMD). The air sampling rates (Rair) of SPMD for OCP were calculated. Quantitative structure-property relationship (QSPR) models of Rair of SPMD were developed for OCP with partial least square (PLS) regression. Quantum chemical descriptors computed by semi-empirical PM6 method were used as predictor variables. The cumulative variance of the dependent variable explained by the PLS components and determined by cross-validation (Q(2)cum), for the optimal models, is 0.637, indicating that the model has good predictive ability and robustness, and could be used to estimate Rair values of OCP. The main factors governing Rair of OCP are intermolecular interactions and the energy required for cave-forming in dissolution of OCP into triolein of SPMD.

  7. Evaluation of passive air sampler calibrations: Selection of sampling rates and implications for the measurement of persistent organic pollutants in air

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Robson, Matthew; Helm, Paul A.; Diamond, Miriam L.

    2011-04-01

    Polyurethane foam (PUF) passive air samplers (PAS) are a common and highly useful method of sampling persistent organic pollutants (POP) concentrations in air. PAS calibration is necessary to obtain reasonable and comparable semi-quantitative measures of air concentrations. Various methods are found in the literature concerning PAS calibration. 35 studies on PAS use and calibration are examined here, in conjunction with a study involving 10 PAS deployed concurrently in outdoor air with a low-volume air sampler in order to measure the sampling rates of PUF-PAS for polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), polycyclic musks (PCMs), and polycyclic aromatic hydrocarbons (PAHs). Based on this analysis it is recommended that (1) PAS should be assumed to represent bulk rather than gas-phase compound concentrations due to the sampling of particle-bound compounds, (2) calibration of PAS sampling rates is more accurately achieved using an active low-volume air sampler rather than depuration compounds since the former measures gas- and particle-phase compounds and does so continuously over the deployment period of the PAS, and (3) homolog-specific sampling rates based on KOA groupings be used in preference to compound/congener-specific or single sampling rates.

  8. The Reproducibility of Indoor Air Pollution (IAP) Measurement: A Test Case for the Measurement of Key Air Pollutants from the Pan Frying of Fish Samples

    PubMed Central

    Kim, Bo-Won; Ahn, Jeong-Hyeon; Bae, Min-Suk; Brown, Richard J. C.

    2014-01-01

    To assess the robustness of various indoor air quality (IAQ) indices, we explored the possible role of reproducibility-induced variability in the measurements of different pollutants under similar sampling and emissions conditions. Polluted indoor conditions were generated by pan frying fish samples in a closed room. A total of 11 experiments were carried out to measure a list of key variables commonly used to represent indoor air pollution (IAP) indicators such as particulate matter (PM: PM1, PM2.5, PM10, and TSP) and a set of individual volatile organic compounds (VOCs) with some odor markers. The cooking activity conducted as part of our experiments was successful to consistently generate significant pollution levels (mean PM10: 7110 μg m−3 and mean total VOC (TVOC): 1400 μg m−3, resp.). Then, relative standard error (RSE) was computed to assess the reproducibility between different IAP paramters measured across the repeated experiments. If the results were evaluated by an arbitrary criterion of 10%, the patterns were divided into two data groups (e.g., <10% for benzene and some aldehydes and >10% for the remainders). Most noticeably, TVOC had the most repeatable results with a reproducibility (RSE) value of 3.2% (n = 11). PMID:25054167

  9. Use of air quality modeling results as exposure estimates in health studies

    NASA Astrophysics Data System (ADS)

    Holmes, H. A.; Ivey, C.; Friberg, M.; Zhai, X.; Balachandran, S.; Hu, Y.; Russell, A. G.; Mulholland, J. A.; Tolbert, P. E.; Sarnat, S. E.

    2013-12-01

    impacts, two techniques are used. The first combines CMAQ results and air quality observations from ambient monitoring networks in a data fusion approach to generate spatially and temporally resolved gaseous and PM species concentrations. The second is a hybrid source-receptor model approach, in which CMAQ source impact estimates are adjusted based on scaling factors obtained using CMAQ results and observations in a CMB-fashion optimization to estimate daily spatially resolved source impacts. Results from St. Louis, Missouri and Atlanta, Georgia will be presented, where source impact estimates were generated for acute health effects studies (e.g., time-series studies of emergency department visits). Spatially resolved air quality metrics developed for a birth cohort study in the state of Georgia will also be shown.

  10. Residues of 2, 4-D in air samples from Saskatchewan: 1966-1975.

    PubMed

    Grover, R; Kerr, L A; Wallace, K; Yoshida, K; Maybank, J

    1976-01-01

    Residues of 2,4-D (2,4-dichlorophenoxyacetic acid) in air samples from several sampling sites in central and southern Saskatchewan during the spraying seasons in the 1966-68 and 1970-75 periods were determined by gas-liquid chromatographic techniques. Initially, individual esters of 2,4-D were characterized by retention times and confirmed further by co-injection and dual column procedures. Since 1973, however, only total 2,4-D acid levels in air samples have been determined after esterification to the methyl ester and confirmed by gc/ms techniques whenever possible. Up to 50% of the daily samples collected during the spraying season at any of the locations and during any given year contained 2,4-D, with butyl esters being found most frequently. The daily 24-hr mean atmospheric concentrations of 2,4-D ranged from 0.01 to 1.22 mug/m3, 0.01 to 13.50 mug/m3, and 0.05 to 0.59 mug/m3 for the iso-propyl, mixed butyl and iso-octyl esters, respectively. Even when the samples were analysed for the total 2,4-D content, i.e. from 1973 onwards, the maximum level of the total acid reached only 23.14 mug/m3. In any given year and at any of the sampling sites, about 30% of the samples contained less than 0.01 mug/m3 of 2,4-D. In another 40% of the samples, the levels of 2,4-D ranged from 0.01 to 0.099 mug/m3. Only about 30% of the samples contained 2,4-D concentrations higher than 0.1 mug/m3, with only 10% or less exceeding 1 mug/m3. None of the samples, obtained with the high volume particulate sampler, showed any detectable levels of 2,4-D, indicating little or no transport of 2,4-D adsorbed on dust particles or as crystals of amine salts. PMID:1002953

  11. Monitoring Iodine-129 in Air and Milk Samples Collected Near the Hanford Site: An Investigation of Historical Iodine Monitoring Data

    SciTech Connect

    Fritz, Brad G.; Patton, Gregory W.

    2006-01-01

    While other research has reported on the concentrations of 129I in the environment surrounding active nuclear fuel reprocessing facilities, there is a shortage of information regarding how the concentrations change once facilities close. At the Hanford Site, the Plutonium-Uranium Extraction (PUREX) chemical separation plant was operational between 1983 and 1990, during which time 129I concentrations in air and milk were measured. After the cessation of operations in 1990, plant emissions decreased 2.5 orders of magnitude over an 8 year period, and monitoring of environmental levels continued. An evaluation of air and milk 129I concentration data spanning the PUREX operation and post closure period was conducted to compare the changes in environmental levels of 129I measured. Measured concentrations over the monitoring period were below levels that could result in a potential human dose greater than 10 uSv. There was a significant and measurable difference in the measured air concentrations of 129I at different distances from the source, indicating a distinct Hanford fingerprint. Correlations between stack emissions of 129I and concentrations in air and milk indicate that atmospheric emissions were responsible for the 129I concentrations measured in environmental samples. The measured concentrations during PUREX operation were similar to observations made around a fuel reprocessing plant in Germany.

  12. STS 134, 135 and 26S Return Samples: Air Quality aboard Shuttle (STS-134) and International Space Station

    NASA Technical Reports Server (NTRS)

    James, John T.

    2011-01-01

    This is a very limited set of samples on which to perform an air quality assessment. However, based on these samples, we have no reason to believe that nominal ISS air is unsafe to breathe. We must continue to be vigilant when dealing with nominal atmospheres in ISS. New, unmanned modules require special attention when the crew first enters. Carbon Monoxide Accumulation aboard ISS: Beginning in late 2008 the nominal concentrations of CO began increasing gradually (Figure 1). The results from samples returned on this flight indicate that the CO concentrations, after dropping in late 2009, have cycled upward and then settled back to concentrations near 2 mg/m3. In any case, these changes are well below the 180-day SMAC for CO, which is17 mg/m3. There is no threat to crew health. Carbon Dioxide: This anthropogenic compound has drawn much attention recently because of the possibility that it could contribute to the effects of intracranial hypertension experienced because of spaceflight-induced fluid shifts. From now on we will maintain a plot (Figure 2) of carbon dioxide concentrations ( SD) by averaging the values found in the 3-5 mini-GSC samples taken each month in diverse locations of the ISS. This will enable us to estimate the average exposure of crewmembers to carbon dioxide during their stay aboard the ISS. In general, concentrations are being maintained below 3.5 mmHg. Figure 1

  13. Final work plan : indoor air and ambient air sampling near the former CCC/USDA grain storage facility in Everest, Kansas.

    SciTech Connect

    LaFreniere, L. M.

    2010-05-24

    The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at the western edge of Everest, Kansas, from the early 1950s to the early 1970s. Sampling by the Kansas Department of Health and Environment (KDHE) in 1997 resulted in the detection of carbon tetrachloride in one domestic well (the Nigh well) northwest of the former facility. On behalf of the CCC/USDA, Argonne National Laboratory subsequently conducted a series of investigations to characterize the contamination (Argonne 2003, 2006a,b,c). Automatic, continuous monitoring of groundwater levels began in 2002 and is ongoing at six locations. The results have consistently indicated groundwater flow toward the north-northwest from the former CCC/USDA property to the Nigh property, then west-southwest from the Nigh property to the intermittent creek. Sitewide periodic groundwater and surface water sampling with analysis for volatile organic compounds (VOCs) began in 2008. Argonne's combined data indicate no significant downgradient extension of contamination since 2000. At present, the sampling is annual, as approved by the KDHE (2009) in response to a plan developed for the CCC/USDA (Argonne 2009). This document presents a plan for collecting indoor air samples in homes located along and adjacent to the defined extent of the carbon tetrachloride contamination. The plan was requested by the KDHE. Ambient air samples to represent the conditions along this pathway will also be taken. The purpose of the proposed work is to satisfy KDHE requirements and to collect additional data for assessing the risk to human health due to the potential upward migration of carbon tetrachloride and its primary degradation product (chloroform) into homes located in close proximity to the former grain storage facility, as well as along and within 100 ft laterally from the currently defined plume emanating from the former Everest facility. Investigation of the indoor air

  14. Evaluation of a portable X-ray fluorescence instrument for the determination of lead in workplace air samples.

    PubMed

    Morley, J C; Clark, C S; Deddens, J A; Ashley, K; Roda, S

    1999-05-01

    Occupational Safety and Health Administration (OSHA) regulations for worker exposure to lead specify worker protection levels based upon airborne concentrations of lead dust. The rapid, on-site determination of lead in air filter samples using a portable x-ray fluorescence (XRF) instrument with an attachment to hold the filter would expedite the exposure assessment process and facilitate compliance with the OSHA standards. A total of 65 lead in air filter samples were collected at bridge blasting lead-abatement projects using closed-faced, 37-mm cassettes with pre-loaded 0.8 micron pore size mixed cellulose ester membrane filters. The lead loading range of the data set was 0.1-1514.6 micrograms (micrograms) of lead/sample. Samples were initially analyzed with a field portable XRF (NITON 700) using an experimental non-destructive XRF method. Samples were subsequently analyzed using National Institute for Occupational Safety and Health (NIOSH) Method 7105 (Graphite Furnace AA) as a reference analytical method. The paired data were not normally distributed; therefore, the non-parametric Wilcoxon signed rank test was used for statistical analysis. There was no statistically significant difference between data from the field portable XRF method and the NIOSH method (p-value = 0.72). Linear regression of the data resulted in a slope of 0.959, a y-intercept of 5.20 micrograms, and an r2 of 0.985. The XRF limit of detection and limit of quantitation were determined to be 6.2 and 17 micrograms of lead/sample, respectively. The XRF method accuracy was +/- 16.4% (7.1%-27%, 90% confidence interval). The data presented in this study indicate that field-portable XRF can be used for the analysis of lead air filter samples over the range of 17 to 1500 micrograms of lead/sample. The practicing industrial hygienist can use field-portable XRF to produce a rapid, on-site determination of lead exposure that can immediately be communicated to workers and help identify appropriate levels

  15. Air Processes Resulting in a Surface Layer Pollution in Industrial Regions

    NASA Astrophysics Data System (ADS)

    Lesin, Yu V.; Leshukov, T. V.

    2016-08-01

    The article describes the air quality research in Western Siberia (Kemerovo region). The problem of air quality preservation in the conditions of mining industry intensive development is caused by the weather conditions which lead either to the concentration of pollutants in the surface layer, or to their migration to other geosphere, or to dissipation as a result of convective mixing or advection of air masses. Zoning of the territory in view of the research results provides insight into areas where the greatest risk to human health and life is formed.

  16. Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns.

    PubMed Central

    Whyatt, Robin M; Barr, Dana B; Camann, David E; Kinney, Patrick L; Barr, John R; Andrews, Howard F; Hoepner, Lori A; Garfinkel, Robin; Hazi, Yair; Reyes, Andria; Ramirez, Judyth; Cosme, Yesenia; Perera, Frederica P

    2003-01-01

    We have measured 29 pesticides in plasma samples collected at birth between 1998 and 2001 from 230 mother and newborn pairs enrolled in the Columbia Center for Children's Environmental Health prospective cohort study. Our prior research has shown widespread pesticide use during pregnancy among this urban minority cohort from New York City. We also measured eight pesticides in 48-hr personal air samples collected from the mothers during pregnancy. The following seven pesticides were detected in 48-83% of plasma samples (range, 1-270 pg/g): the organophosphates chlorpyrifos and diazinon, the carbamates bendiocarb and 2-isopropoxyphenol (metabolite of propoxur), and the fungicides dicloran, phthalimide (metabolite of folpet and captan), and tetrahydrophthalimide (metabolite of captan and captafol). Maternal and cord plasma levels were similar and, except for phthalimide, were highly correlated (p < 0.001). Chlorpyrifos, diazinon, and propoxur were detected in 100% of personal air samples (range, 0.7-6,010 ng/m(3)). Diazinon and propoxur levels were significantly higher in the personal air of women reporting use of an exterminator, can sprays, and/or pest bombs during pregnancy compared with women reporting no pesticide use or use of lower toxicity methods only. A significant correlation was seen between personal air level of chlorpyrifos, diazinon, and propoxur and levels of these insecticides or their metabolites in plasma samples (maternal and/or cord, p < 0.05). The fungicide ortho-phenylphenol was also detected in 100% of air samples but was not measured in plasma. The remaining 22 pesticides were detected in 0-45% of air or plasma samples. Chlorpyrifos, diazinon, propoxur, and bendiocarb levels in air and/or plasma decreased significantly between 1998 and 2001. Findings indicate that pesticide exposures are frequent but decreasing and that the pesticides are readily transferred to the developing fetus during pregnancy. PMID:12727605

  17. Sampling and measurement issues in establishing a climate reference upper air network

    NASA Astrophysics Data System (ADS)

    Gardiner, T.; Madonna, F.; Wang, J.; Whiteman, D. N.; Dykema, J.; Fassò, A.; Thorne, P. W.; Bodeker, G.

    2013-09-01

    The GCOS Reference Upper Air Network (GRUAN) is an international reference observing network, designed to meet climate requirements and to fill a major void in the current global observing system. Upper air observations within the GRUAN network will provide long-term high-quality climate records, will be used to constrain and validate data from space based remote sensors, and will provide accurate data for the study of atmospheric processes. The network covers measurements of a range of key climate variables including temperature. Implementation of the network has started, and as part of this process a number of scientific questions need to be addressed in order to establish a viable climate reference upper air network, in addition to meeting the other objectives for the network measurements. These include quantifying collocation issues for different measurement techniques including the impact on the overall uncertainty of combined measurements; change management requirements when switching between sensors; assessing the benefit of complementary measurements of the same variable using different measurement techniques; and establishing the appropriate sampling strategy to determine long-term trends. This paper reviews the work that is currently underway to address these issues.

  18. SAMPLE RESULTS FROM THE INTEGRATED SALT DISPOSITION PROGRAM MACROBATCH 5 TANK 21H QUALIFICATION MST, ESS AND PODD SAMPLES

    SciTech Connect

    Peters, T.; Fink, S.

    2012-04-24

    Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Integrated Salt Disposition Program (ISDP) Batch 5 processing. This qualification material was a composite created from recent samples from Tank 21H and archived samples from Tank 49H to match the projected blend from these two tanks. Additionally, samples of the composite were used in the Actinide Removal Process (ARP) and extraction-scrub-strip (ESS) tests. ARP and ESS test results met expectations. A sample from Tank 21H was also analyzed for the Performance Objectives Demonstration Document (PODD) requirements. SRNL was able to meet all of the requirements, including the desired detection limits for all the PODD analytes. This report details the results of the Actinide Removal Process (ARP), Extraction-Scrub-Strip (ESS) and Performance Objectives Demonstration Document (PODD) samples of Macrobatch (Salt Batch) 5 of the Integrated Salt Disposition Program (ISDP).

  19. An Improved, Automated Whole-Air Sampler and VOC Analysis System: Results from SONGNEX 2015

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Gilman, J.; Tokarek, T. W.; Peischl, J.; Koss, A.; Yuan, B.; Warneke, C.; Isaacman-VanWertz, G. A.; Sueper, D.; De Gouw, J. A.; Aikin, K. C.

    2015-12-01

    Accurate measurement of volatile organic compounds (VOCs) in the troposphere is critical for the understanding of emissions and physical and chemical processes that can impact both air quality and climate. Airborne VOC measurements have proven challenging due to the requirements of short sample collection times (=10 s) to maximize spatial resolution and sampling frequency and high sensitivity (pptv) to chemically diverse hydrocarbons, halocarbons, oxygen- and nitrogen-containing VOCs. NOAA ESRL CSD has built an improved whole air sampler (iWAS) which collects compressed ambient air samples in electropolished stainless steel canisters, based on the NCAR HAIS Advanced Whole Air Sampler [Atlas and Blake]. Post-flight chemical analysis is performed with a custom-built gas chromatograph-mass spectrometer system that pre-concentrates analyte cryostatically via a Stirling cooler, an electromechanical chiller which precludes the need for liquid nitrogen to reach trapping temperatures. For the 2015 Shale Oil and Natural Gas Nexus Study (SONGNEX), CSD conducted iWAS measurements on 19 flights aboard the NOAA WP-3D aircraft between March 19th and April 27th. Nine oil and natural gas production regions were surveyed during SONGNEX and more than 1500 air samples were collected and analyzed. For the first time, we employed real-time mapping of sample collection combined with live data from fast time-response measurements (e.g. ethane) for more uniform surveying and improved target plume sampling. Automated sample handling allowed for more than 90% of iWAS canisters to be analyzed within 96 hours of collection - for the second half of the campaign improved efficiencies reduced the median sample age at analysis to 36 hours. A new chromatography peak-fitting software package was developed to minimize data reduction time by an order of magnitude without a loss of precision or accuracy. Here we report mixing ratios for aliphatic and aromatic hydrocarbons (C2-C8) along with select

  20. STS 129 Return Samples: Assessment of Air Quality aboard the Shuttle (STS-129) and International Space Station (ULF3)

    NASA Technical Reports Server (NTRS)

    James, John T.

    2010-01-01

    Reports on the air quality aboard the Space Shuttle (STS-129), and the International Space station (ULF3). NASA analyzed the grab sample canisters (GSCs) and the formaldehyde badges aboard both locations for carbon monoxide levels. The three surrogates: (sup 13)C-acetone, fluorobenzene, and chlorobenzene registered 109, 101, and 109% in the space shuttle and 81, 87, and 55% in the International Space Station (ISS). From these results the atmosphere in both the Space Shuttle and the International Space Station (ISS) was found to be breathable.

  1. Ram-air sample collection device for a chemical warfare agent sensor

    DOEpatents

    Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.

    2002-01-01

    In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.

  2. New Brunswick air quality monitoring results for the years 1996 and 1997. Technical report number T-9901

    SciTech Connect

    Not Available

    1999-01-01

    This report summarizes air quality monitoring data from New Brunswick during 1996 and 1997, with an emphasis on air quality assessment in relation to existing air quality standards and objectives. Introductory sections review provincial air quality legislation, national and provincial standards, other air quality criteria, sources and effects of regulated air pollutants, and air quality monitoring networks in the province. Results are presented by area, corporation, or network monitored, and are discussed and compared with data from centres in other parts of the world. Air pollutants monitored include nitrogen oxides, hydrogen sulphide, particulates, ozone, acid precipitation, carbon monoxide, and sulphur dioxide. Appendices include a glossary and detailed monthly monitoring results.

  3. New Brunswick air quality monitoring results for the years 1996 and 1997. Technical report number T-9901

    SciTech Connect

    1999-11-01

    This report summarizes air quality monitoring data from New Brunswick during 1996 and 1997, with an emphasis on air quality assessment in relation to existing air quality standards and objectives. Introductory sections review provincial air quality legislation, national and provincial standards, other air quality criteria, sources and effects of regulated air pollutants, and air quality monitoring networks in the province. Results are presented by area, corporation, or network monitored, and are discussed and compared with data from centres in other parts of the world. Air pollutants monitored include nitrogen oxides, hydrogen sulphide, particulates, ozone, acid precipitation, carbon monoxide, and sulphur dioxide. Appendices include a glossary and detailed monthly monitoring results.

  4. BIBLE A whole-air sampling as a window on Asian biogeochemistry

    NASA Astrophysics Data System (ADS)

    Elliott, Scott; Blake, Donald R.; Blake, Nicola J.; Dubey, Manvendra K.; Rowland, F. Sherwood; Sive, Barkley C.; Smith, Felisa A.

    2003-02-01

    Asian trace gas and aerosol emissions into carbon, nitrogen, and other elemental cycles will figure prominently in near term Earth system evolution. Atmospheric hydrocarbon measurements resolve numerous chemical species and can be used to investigate sourcing for key geocarriers. A recent aircraft study of biomass burning and lightning (BIBLE A) explored the East Asian atmosphere and was unique in centering on the Indonesian archipelago. Samples of volatile organics taken over/between the islands of Japan, Saipan, Java, and Borneo are here examined as a guide to whole-air-based studies of future Asian biogeochemistry. The midlatitude onshore/offshore pulse and tropical convection strongly influence concentration distributions. As species of increasing molecular weight are considered, rural, combustion, and industrial source regimes emerge. Methane-rich inputs such as waste treatment and rice cultivation are evidenced in the geostrophic outflow. The Indonesian atmosphere is rich in biomass burning markers and also those of vehicular activity. Complexity of air chemistry in the archipelago is a direct reflection of diverse topography, land use, and local economies in a rapidly developing nation. Conspicuous in its absence is the fingerprint for liquefied petroleum gas leakage, but it can be expected to appear as demand for clean fossil fuels rises along with per capita incomes. Combustion tracers indicate high nitrogen mobilization rates, linking regional terrestrial geocycles with open marine ecosystems. Sea to air fluxes are superimposed on continental and marine backgrounds for the methyl halides. However, ocean hot spots are not coordinated and suggest an intricate subsurface kinetics. Levels of long-lived anthropogenic halocarbons attest to the success of international environmental treaties while reactive chlorine containing species track industrial air masses. The dozens of hydrocarbons resolvable by gas chromatographic methods will enable monitoring of

  5. Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air.

    PubMed

    Attari, Seyed Ghavameddin; Bahrami, Abdolrahman; Shahna, Farshid Ghorbani; Heidari, Mahmoud

    2014-01-01

    A green, environmental friendly and sensitive method for determination of volatile organohalogen compounds was described in this paper. The method is based on a homemade sol-gel single-walled carbon nanotube/silica composite coated solid-phase microextraction to develop for sampling and analysis of Carbon tetrachloride, Benzotrichloride, Chloromethyl methyl ether and Trichloroethylene in air. Application of this method was investigated under different laboratory conditions. Predetermined concentrations of each analytes were prepared in a home-made standard chamber and the influences of experimental parameters such as temperature, humidity, extraction time, storage time, desorption temperature, desorption time and the sorbent performance were investigated. Under optimal conditions, the use of single-walled carbon nanotube/silica composite fiber showed good performance, high sensitive and fast sampling of volatile organohalogen compounds from air. For linearity test the regression correlation coefficient was more than 98% for analyte of interest and linear dynamic range for the proposed fiber and the applied Gas Chromatography-Flame Ionization Detector technique was from 1 to 100 ngmL(-1). Method detection limits ranged between 0.09 to 0.2 ngmL(-1) and method quantification limits were between 0.25 and 0.7 ngmL(-1). Single-walled carbon nanotube/silica composite fiber was highly reproducible, relative standard deviations were between 4.3 to 11.7 percent. PMID:25279223

  6. 6S Return Samples: Assessment of Air Quality in the International Space Station (ISS) Based on Solid Sorbent Air Sampler (SSAS) and Formaldehyde Monitoring Kit (FMK) Analyses

    NASA Technical Reports Server (NTRS)

    James, John T.

    2004-01-01

    The toxicological assessments of SSAS and FMK analytical results are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the SSAS tubes were 66-76% for 13C-acetone, 85-96% for fluorobenzene, and 73-89% for chlorobenzene. Post-flight flows were far below pre-flight flows and an investigation of the problem revealed that the reduced flow was caused by a leak at the interface of the pump inlet tube and the pump head. This resulted in degradation of pump efficiency. Further investigation showed that the problem occurred before the SSAS was operated on orbit and that use of the post-flight flows yielded consistent and useful results. Recoveries from formaldehyde control badges were 86 to 104%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). The T values will not be reported for these data due to the flow anomaly. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) is not efficiently trapped by the sorbents used in the SSAS. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. These five indices of air quality are summarized.

  7. DNA sequences identical to Pneumocystis carinii f. sp. carinii and Pneumocystis carinii f. sp. hominis in samples of air spora.

    PubMed Central

    Wakefield, A E

    1996-01-01

    Samples of ambient air collected with three different types of spore traps in a rural location were examined for the presence of Pneumocystis carinii by screening for P. carinii-specific DNA sequences by DNA amplification. Eleven spore trap samples were analyzed by nested PCR, using oligonucleotide primers designed for the gene encoding the mitochondrial large subunit rRNA of P. carinii f. sp. carinii and P. carinii f. sp. hominis. The samples were collected over a 3-year period during the months of May to September, with a range of sampling times from 9 to 240 h. One air sample from an animal facility housing P. carinii-infected rats was also examined. P. carinii-specific amplification products were obtained from samples from each of the spore traps. The amplification products from eight air samples were cloned and sequenced. The majority of the recombinants from each of these samples had sequences identical to those of P. carinii f. sp. carinii and P. carinii f. sp. hominis, and a number of clones had single-base differences. These data suggest that sequences identical to those of P. carinii f. sp. carinii and P. carinii f. sp. hominis can be detected in samples of air collected in a rural location and that P. carinii may be a component of the air spora of rural Oxfordshire. PMID:8784583

  8. ANASORB{reg_sign} 747 - A universal sorbent for air sampling?

    SciTech Connect

    Harper, M.

    1997-12-31

    A sorbent to be used for air sampling must meet certain performance criteria including sample background, capacity, stability, and recovery. Anasorb{sup R} 747 is a proprietary 20/40 mesh beaded active carbon prepared from raw materials with a very low ash content in a process which creates a regular pore structure. The background is very low for both inorganic and organic species, and the surface is more inert and less hydrophilic than coconut charcoal, while capacity is similar. The low catalytic activity of the surface means samples of many reactive compounds remain stable for longer periods. The sorbent is compatible with most solvent systems in use (e.g. carbon disulfide, methylene chloride, methanol, dimethyformamide). Anasorb 747 can be coated with chemicals for efficient adsorption of inorganic gases, which can be analyzed at very low levels because of low background interference. A large number of validated sampling methods use Anasorb 747, including methods from OSHA and NIOSH, corporate industrial hygiene laboratories, various branches of the EPA, and international agencies. These methods refer to around fifty different gases and vapors. Although this sorbent is not compatible with some compounds (e.g. low molecular weight aldehydes) it is quite close to being of universal application.

  9. Total Particulate Matter Air Sampling Data (TEOM) from Los Alamos National Laboratory

    DOE Data Explorer

    LANL measures the total particulate mass concentration in the air on a routine basis as well as during incidents that may affect ambient air. The collected data is added to the Air Quality Index (AQI). AQI is an index for reporting daily air quality. It tells you how clean or polluted your air is, and what associated health effects might be a concern for you. The AQI focuses on health effects you may experience within a few hours or days after breathing polluted air. EPA calculates the AQI for five major air pollutants regulated by the Clean Air Act.

  10. Shuttle Entry Air Data System (SEADS) - Optimization of preflight algorithms based on flight results

    NASA Technical Reports Server (NTRS)

    Wolf, H.; Henry, M. W.; Siemers, Paul M., III

    1988-01-01

    The SEADS pressure model algorithm results were tested against other sources of air data, in particular, the Shuttle Best Estimated Trajectory (BET). The algorithm basis was also tested through a comparison of flight-measured pressure distribution vs the wind tunnel database. It is concluded that the successful flight of SEADS and the subsequent analysis of the data shows good agreement between BET and SEADS air data.

  11. Evolution of Fuel-Air and Contaminant Clouds Resulting from a Cruise Missile Explosion Scenario

    SciTech Connect

    Grossman, A S; Kul, A L

    2005-06-22

    A low-mach-number hydrodynamics model has been used to simulate the evolution of a fuel-air mixture and contaminant cloud resulting from the detonation of a cruise missile. The detonation has been assumed to be non-nuclear. The cloud evolution has been carried out to a time of 5.5 seconds. At this time the contaminant has completely permeated the initial fuel-air mixture cloud.

  12. Tank vapor characterization project. Headspace vapor characterization of Hanford waste tank 241-BY-108: Second comparison study results from samples collected on 3/28/96

    SciTech Connect

    Thomas, B.L.; Pool, K.H.; Evans, J.C.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-BY-108 (Tank BY-108) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H{sub 2}O) and ammonia (NH{sub 3}), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA{trademark} canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC.

  13. Tank vapor characterization project - headspace vapor characterization of Hanford Waste Tank 241-C-107: Second comparison study results from samples collected on 3/26/96

    SciTech Connect

    Evans, J.C.; Pool, K.H.; Thomas, B.L.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-C-107 (Tank C-107) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H{sub 2}O) and ammonia (NH{sub 3}), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA{trademark} canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC.

  14. Tank vapor characterization project: Headspace vapor characterization of Hanford Waste Tank 241-S-102: Second comparison study results from samples collected on 04/04/96

    SciTech Connect

    Pool, K.H.; Evans, J.C.; Thomas, B.J.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-S-102 (Tank S-102) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H{sub 2}O) and ammonia (NH{sub 3}), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA{trademark} canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC.

  15. Tank Vapor Characterization Project -- Headspace vapor characterization of Hanford waste Tank 241-C-107: Results from samples collected on 01/17/96

    SciTech Connect

    Thomas, B.L.; Evans, J.C.; Pool, K.H.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

    1996-07-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-C-107 (Tank C-107) at the Hanford Site in Washington State. The results described in this report were obtained to compare vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system with and without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H{sub 2}O) and ammonia (NH{sub 3}), permanent gases, total non-methane hydrocarbons (TO-12), and individual organic analytes collected in SUMMA{trademark} canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC.

  16. Storage of LWR spent fuel in air. Volume 3, Results from exposure of spent fuel to fluorine-contaminated air

    SciTech Connect

    Cunningham, M.E.; Thomas, L.E.

    1995-06-01

    The Behavior of Spent Fuel in Storage (BSFS) Project has conducted research to develop data on spent nuclear fuel (irradiated U0{sub 2}) that could be used to support design, licensing, and operation of dry storage installations. Test Series B conducted by the BSFS Project was designed as a long-term study of the oxidation of spent fuel exposed to air. It was discovered after the exposures were completed in September 1990 that the test specimens had been exposed to an atmosphere of bottled air contaminated with an unknown quantity of fluorine. This exposure resulted in the test specimens reacting with both the oxygen and the fluorine in the oven atmospheres. The apparent source of the fluorine was gamma radiation-induced chemical decomposition of the fluoro-elastomer gaskets used to seal the oven doors. This chemical decomposition apparently released hydrofluoric acid (HF) vapor into the oven atmospheres. Because the Test Series B specimens were exposed to a fluorine-contaminated oven atmosphere and reacted with the fluorine, it is recommended that the Test Series B data not be used to develop time-temperature limits for exposure of spent nuclear fuel to air. This report has been prepared to document Test Series B and present the collected data and observations.

  17. Monitoring, sampling and analysis of fine particulates -- Results and experiences from DOE's Federal Energy Technology Center

    SciTech Connect

    White, C.M.; Anderson, R.; Martello, D.; Rohar, P.; George, E.; Irdi, G.; Veloski, G.; Tamilia, J.; Lynn, R.; Waldner, K.; Hickey, R.; Feeley, T.; Casuccio, G.S.; Schlaegle, S.F.; Doerr, A.

    1999-07-01

    The overall goal of the DOE fine particulate program is to ensure that the best science and technology is available for any regulatory decision-making related to the health and environmental impacts of ambient fine particulate matter and regional haze. Interest primarily lies in the particulate fraction having aerodynamic diameters of 2.5 microns and less (PM2.5). Particulates of this size are the focus of the newly established National Ambient Air Quality Standards. As such, the Federal Energy Technology Center (FETC) is establishing a fine particulate sampling station at the Center's Pittsburgh site located in South Park Township, PA. This sampling station is one of a group of stations scattered throughout Pennsylvania, West Virginia, and Ohio that constitute the Upper Ohio River Valley Project. The station is equipped with a full complement of fine particulate and gaseous monitors including the following: (1) R and P Sequential FRM sampler, (2) Grimm PM2.5 continuous sampler, (3) TSI Dustrak PM2.5 continuous sampler, (4) R and P TEOM equipped with an AccuSampler, (5) Andersen speciation sampler, (6) MetOne speciation sampler, (7) EcoChem continuous PAH monitor, (8) Total peroxide monitor that employs the Greg Kok method, (9) Burkard 7 day pollen and mold spore sampler, (10) Continuous gas monitors for O{sub 3}, SO{sub 2}, NH{sub 3}, CO, H{sub 2}S, NO{sub y}, NO{sub x}, and (11) Meteorological instruments. The presentation will describe the initial results for the summer 1999 season from the above instruments. The chemical analysis of the aqueous extracts of the FRM filters will be discussed, including the anions present as determined by ion chromatography, and the metals present.

  18. Air-Based Remediation Workshop - Section 1 Sampling And Analysis Revelant To Air-Based Remediation Technologies

    EPA Science Inventory

    Pursant to the EPA-AIT Implementing Arrangement 7 for Technical Environmental Collaboration, Activity 11 "Remediation of Contaminated Sites," the USEPA Office of International Affairs Organized a Force Air Remediation Workshop in Taipei to deliver expert training to the Environme...

  19. Daily air quality forecast (gases and aerosols) over Switzerland. Modeling tool description and first results analysis.

    NASA Astrophysics Data System (ADS)

    Couach, O.; Kirchner, F.; Porchet, P.; Balin, I.; Parlange, M.; Balin, D.

    2009-04-01

    Map3D, the acronym for "Mesoscale Air Pollution 3D modelling", was developed at the EFLUM laboratory (EPFL) and received an INNOGRANTS awards in Summer 2007 in order to move from a research phase to a professional product giving daily air quality forecast. It is intended to give an objective base for political decisions addressing the improvement of regional air quality. This tool is a permanent modelling system which provides daily forecast of the local meteorology and the air pollutant (gases and particles) concentrations. Map3D has been successfully developed and calculates each day at the EPFL site a three days air quality forecast over Europe and the Alps with 50 km and 15 km resolution, respectively (see http://map3d.epfl.ch). The Map3D user interface is a web-based application with a PostgreSQL database. It is written in object-oriented PHP5 on a MVC (Model-View-Controller) architecture. Our prediction system is operational since August 2008. A first validation of the calculations for Switzerland is performed for the period of August 2008 - January 2009 comparing the model results for O3, NO2 and particulates with the results of the Nabel measurements stations. The subject of air pollution regimes (NOX/VOC) and specific indicators application with the forecast will be also addressed.

  20. Monitoring organic nitrogen species in the UT/LS - a new system for analysis of CARIBIC whole air samples

    NASA Astrophysics Data System (ADS)

    Sauvage, Carina; Thorenz, Ute; Baker, Angela; Brenninkmeijer, Carl; Williams, Jonathan

    2014-05-01

    -concentrated, then focused cryogenically, and then separated by GC. The eluting nitrogen compounds are combusted to NO in a plasma burner and reacted with ozone to yield excited NO2 which emits light in the near infrared detectable by a photomultiplier. The instrument set up and results of method characterization with acetonitrile,N2O and the first organic nitrate measurements of whole air samples will be shown.

  1. Unmanned platform for long-range remote analysis of volatile compounds in air samples.

    PubMed

    da Costa, Eric T; Neves, Carlos A; Hotta, Guilherme M; Vidal, Denis T R; Barros, Marcelo F; Ayon, Arturo A; Garcia, Carlos D; do Lago, Claudimir Lucio

    2012-09-01

    This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV.

  2. Unmanned platform for long-range remote analysis of volatile compounds in air samples.

    PubMed

    da Costa, Eric T; Neves, Carlos A; Hotta, Guilherme M; Vidal, Denis T R; Barros, Marcelo F; Ayon, Arturo A; Garcia, Carlos D; do Lago, Claudimir Lucio

    2012-09-01

    This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV. PMID:22965708

  3. 24-HOUR DIFFUSIVE SAMPLING OF TOXIC VOCS IN AIR ONTO CARBOPACK X SOLID ADSORBENT FOLLOWED BY THERMAL DESORPTION/GC/MS ANALYSIS - LABORATORY STUDIES

    EPA Science Inventory

    Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity, and ozon...

  4. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  5. Organic analysis of ambient samples collected near Tank 241-C-103: Results from samples collected on May 12, 1994

    SciTech Connect

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Lucke, R.B.; Young, J.S.; McCulloch, M.; Fruchter, J.S.; Goheen, S.C.

    1995-06-01

    This report describes organic analyses results from ambient samples collected both upwind and through the vapor sampling system (VSS) near Hanford waste storage Tank 241-C-103 (referred to as Tank C-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed. Quantitative results were obtained for organic compounds. Five organic tentatively identified compounds (TICS) were observed above the detection limit of (ca.) 10 ppbv, but standards for most of these were not available at the time of analysis, and the reported concentrations are semiquantitative estimates. In addition, we looked for the 40 standard TO-14 analytes. We observed 39. Of these, only one was observed above the 2-ppbv calibrated instrument detection limit. Dichloromethane was above the detection limits using both methods, but the result from the TO-14 method is traceable to a standard gas mixture and is considered more accurate. Organic analytes were found only in the sample collected through the VSS, suggesting that these compounds were residual contamination from a previous sampling job. Detailed descriptions of the results appear in the text.

  6. Test results and analysis of a convective loop solar air collector

    SciTech Connect

    Biehl, F.A.

    1981-01-01

    The test results and analysis methods employed in studying the general design parameters of an air convective loop solar collector are presented. The purpose of the test program is to validate a simulation model that can also be extended to other collector arrangements and to a variety of weather patterns. Details of the collector configurations, typical test results, simulation model, and comparison between test and analysis results are discussed. The good agreement between test and analysis suggests that the analytical model can be employed for sensitivity studies. Results (not presented here) show that the collector efficiency, mass flow rate, and air temperature gain are sensitive to the air passage depth behind the absorber plate. A range of desirable collector lengths, based upon efficiency considerations, is determined employing the analytical model.

  7. Thermodynamic, transport, and flow properties of gaseous products resulting from combustion of methane-air-oxygen

    NASA Technical Reports Server (NTRS)

    Klich, G. F.

    1976-01-01

    Results of calculations to determine thermodynamic, transport, and flow properties of combustion product gases are presented. The product gases are those resulting from combustion of methane-air-oxygen and methane-oxygen mixtures. The oxygen content of products resulting from the combustion of methane-air-oxygen mixtures was similiar to that of air; however, the oxygen contained in products of methane-oxygen combustion ranged from 20 percent by volume to zero for stoichiometric combustion. Calculations were made for products of reactant mixtures with fuel percentages, by mass, of 7.5 to 20. Results are presented for specific mixtures for a range of pressures varying from 0.0001 to 1,000 atm and for temperatures ranging from 200 to 3,800 K.

  8. Use of Respondent Driven Sampling (RDS) Generates a Very Diverse Sample of Men Who Have Sex with Men (MSM) in Buenos Aires, Argentina

    PubMed Central

    Carballo-Diéguez, Alex; Balan, Ivan; Marone, Rubén; Pando, María A.; Dolezal, Curtis; Barreda, Victoria; Leu, Cheng-Shiun; Ávila, María Mercedes

    2011-01-01

    Background Prior research focusing on men who have sex with men (MSM) conducted in Buenos Aires, Argentina, used convenience samples that included mainly gay identified men. To increase MSM sample representativeness, we used Respondent Driven Sampling (RDS) for the first time in Argentina. Using RDS, under certain specified conditions, the observed estimates for the percentage of the population with a specific trait are asymptotically unbiased. We describe, the diversity of the recruited sample, from the point of view of sexual orientation, and contrast the different subgroups in terms of their HIV sexual risk behavior. Methodology 500 MSM were recruited using RDS. Behavioral data were collected through face-to-face interviews and Web-based CASI. Conclusion In contrast with prior studies, RDS generated a very diverse sample of MSM from a sexual identity perspective. Only 24.5% of participants identified as gay; 36.2% identified as bisexual, 21.9% as heterosexual, and 17.4% were grouped as “other.” Gay and non-gay identified MSM differed significantly in their sexual behavior, the former having higher numbers of partners, more frequent sexual contacts and less frequency of condom use. One third of the men (gay, 3%; bisexual, 34%, heterosexual, 51%; other, 49%) reported having had sex with men, women and transvestites in the two months prior to the interview. This population requires further study and, potentially, HIV prevention strategies tailored to such diversity of partnerships. Our results highlight the potential effectiveness of using RDS to reach non-gay identified MSM. They also present lessons learned in the implementation of RDS to recruit MSM concerning both the importance and limitations of formative work, the need to tailor incentives to circumstances of the less affluent potential participants, the need to prevent masking, and the challenge of assessing network size. PMID:22102896

  9. Sampling of power plant stacks for air toxic emissions: Topical report for Phases 1 and 2

    SciTech Connect

    1995-02-21

    Under contract with the US Department of Energy (DE-AC22-92PCO0367), Pittsburgh Energy Technology Center, Radian Corporation has conducted a test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPS). Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical charactization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions.

  10. Pteam: Monitoring of phthalates and PAHs in indoor and outdoor air samples in Riverside, California. Volume 2. Final report

    SciTech Connect

    Sheldon, L.; Clayton, A.; Keever, J.; Perritt, R.; Whitaker, D.

    1992-12-01

    The primary purpose of the study was to obtain indoor and outdoor air concentration data for benzo(a)pyrene, other polynuclear aromatic hydrocarbons (PAHs), and phthalates in California residences to be used in making exposure predictions. To meet these objectives, a field monitoring study was performed in 125 homes in Riverside, California in the fall of 1990. In each home, two 12-hour indoor air samples were collected during daytime and overnight periods. In a subset of 65 homes, outdoor air samples were also collected. PAH and phthalate concentrations were measured in collected air samples using gas chromatography/mass spectrometry techniques. Along with field monitoring, information on potential source usage in the home was collected using questionnaires.

  11. Spectral fingerprinting of polycyclic aromatic hydrocarbons in high-volume ambient air samples by constant energy synchronous luminescence spectroscopy

    USGS Publications Warehouse

    Kerkhoff, M.J.; Lee, T.M.; Allen, E.R.; Lundgren, D.A.; Winefordner, J.D.

    1985-01-01

    A high-volume sampler fitted with a glass-fiber filter and backed by polyurethane foam (PUF) was employed to collect airborne particulate and gas-phase polycylic aromatic hydrocarbons (PAHs) in ambient air. Samples were collected from four sources representing a range of environmental conditions: gasoline engine exhaust, diesel engine exhaust, air near a heavily traveled interstate site, and air from a moderately polluted urban site. Spectral fingerprints of the unseparated particulate and gas-phase samples were obtained by constant energy synchronous luminescence spectroscopy (CESLS). Five major PAHs in the gas-phase extracts were characterized and estimated. The compatibility of a high-volume sampling method using polyurethane foam coupled with CESLS detection is explored for use as a screening technique for PAHs in ambient air. ?? 1985 American Chemical Society.

  12. RAZOR EX Anthrax Air Detection System for detection of Bacillus anthracis spores from aerosol collection samples: collaborative study.

    PubMed

    Hadfield, Ted; Ryan, Valorie; Spaulding, Usha K; Clemens, Kristine M; Ota, Irene M; Brunelle, Sharon L

    2013-01-01

    The RAZOR EX Anthrax Air Detection System was validated in a collaborative study for the detection of Bacillus anthracis in aerosol collection buffer. Phosphate-buffered saline was charged with 1 mg/mL standardized dust to simulate an authentic aerosol collection sample. The dust-charged buffer was spiked with either B. anthracis Ames at 2000 spores/mL or Bacillus cereus at 20 000 spores/mL. Twelve collaborators participated in the study, with four collaborators at each of three sites. Each collaborator tested 12 replicates of B. anthracis in dust-charged buffer and 12 replicates of B. cereus in dust-charged buffer. All samples sets were randomized and blind-coded. All collaborators produced valid data sets (no collaborators displayed systematic errors) and there was only one invalid data point. After unblinding, the analysis revealed a cross-collaborator probability of detection (CPOD) of 1.00 (144 positive results from 144 replicates, 95% confidence interval 0.975-1.00) for the B. anthracis samples and a CPOD of 0.00 (0 positive results from 143 replicates, 95% confidence interval 0.00-0.0262) for the B. cereus samples. These data meet the requirements of AOAC Standard Method Performance Requirement 2010.003, developed by the Stakeholder Panel on Agent Detection Assays. PMID:23767365

  13. On eddy accumulation with limited conditional sampling to measure air-surface exchange

    SciTech Connect

    Wesely, M.L.; Hart, R.L.

    1994-01-01

    An analysis of turbulence data collected at a height of 12.3 m above grasslands was carried out to illustrate some of the limitations and possible improvements in methods to compute vertical fluxes of trace substances by the eddy accumulation technique with conditional sampling. The empirical coefficient used in the technique has a slight dependence on atmospheric stability, which can be minimized by using a threshold vertical velocity equal to approximately 0.75{sigma}{sub w}, below which chemical sampling is suspended. This protocol results in a smaller chemical sample but increases the differences in concentrations by approximately 70%. For effective conditional sampling when mass is being accumulated in a trap or reservoir, the time of sampling during updrafts versus downdrafts should be measured and used to adjust estimates of the mean concentrations.

  14. Increasing concentrations of dichloromethane, CH2Cl2, inferred from CARIBIC air samples collected 1998-2012

    NASA Astrophysics Data System (ADS)

    Leedham Elvidge, E. C.; Oram, D. E.; Laube, J. C.; Baker, A. K.; Montzka, S. A.; Humphrey, S.; O'Sullivan, D. A.; Brenninkmeijer, C. A. M.

    2014-08-01

    Dichloromethane, CH2Cl2, is a short-lived chlorocarbon of predominantly anthropogenic origin. Increasing industrial usage and associated emissions resulted in an increasing atmospheric burden throughout the 1900s. Atmospheric abundance peaked around 1990 and was followed by a decline in the early part of the 21st century. Despite the importance of ongoing monitoring and reporting of atmospheric CH2Cl2 (it is a regulated toxic air pollutant and a contributor to stratospheric ozone depletion) no time series has been discussed in detail since 2006. The CARIBIC project (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container) has analysed the halocarbon content of whole air samples collected at altitudes of between ~10-12 km via a custom-built container installed on commercial passenger aircraft since 1998, providing a long-term record of CH2Cl2 observations. In this paper we present this unique CH2Cl2 time series, discussing key flight routes which have been traversed at various times over the past 15 years. Between 1998 and 2012 increases were seen in all northern hemispheric regions and at different altitudes, ranging from ~7-9 ppt in background air to ~12-15 ppt in regions with stronger emissions (equating to a 38-69% increase). Of particular interest is the rising importance of India as a source of atmospheric CH2Cl2: based on CARIBIC data we provide regional emission estimates for the Indian subcontinent and show that regional emissions have increased from 3-15 Gg yr-1 (1998-2000) to 16-25 Gg yr-1 (2008). Potential causes of the increasing atmospheric burden of CH2Cl2 are discussed. One possible source is the increased use of CH2Cl2 as a feedstock for the production of HFC-32, a chemical used predominantly as a replacement for ozone-depleting substances in a variety of applications including air conditioners and refrigeration.

  15. SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-13-1403/1404/1405/1406/1407/1408: QUARTERLY SAMPLE FROM SEPTEMBER 2013

    SciTech Connect

    Fondeur, F.; Taylor-Pashow, K.

    2013-11-20

    Savannah River National Laboratory (SRNL) analyzed solvent samples from the Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-1403, MCU-13-1404, MCU-13-1405, MCU-13-1406, MCU-13-1407, and MCU-13-1408 received on September 17, 2013 are reported. This sample was taken after the addition of the Next Generation Solvent (NGS) cocktail to produce a NGS-MCU blended solvent. The results show that the solvent contains a slight excess of Isopar L and a deficit concentration of modifier and TiDG when compared to the target composition. Addition of TiDG trim is recommended. SRNL also analyzed the SHT sample for {sup 137}Cs content and determined the measured value is within tolerance and that the value has returned to levels observed in 2011. In contrast to what was observed in the heel prior to adding the NGS cocktail, no organic impurities were detected in these solvent samples.

  16. Oil and gas impacts on air quality in federal lands in the Bakken region: an overview of the Bakken Air Quality Study and first results

    NASA Astrophysics Data System (ADS)

    Prenni, A. J.; Day, D. E.; Evanoski-Cole, A. R.; Sive, B. C.; Hecobian, A.; Zhou, Y.; Gebhart, K. A.; Hand, J. L.; Sullivan, A. P.; Li, Y.; Schurman, M. I.; Desyaterik, Y.; Malm, W. C.; Collett, J. L., Jr.; Schichtel, B. A.

    2016-02-01

    The Bakken formation contains billions of barrels of oil and gas trapped in rock and shale. Horizontal drilling and hydraulic fracturing methods have allowed for extraction of these resources, leading to exponential growth of oil production in the region over the past decade. Along with this development has come an increase in associated emissions to the atmosphere. Concern about potential impacts of these emissions on federal lands in the region prompted the National Park Service to sponsor the Bakken Air Quality Study over two winters in 2013-2014. Here we provide an overview of the study and present some initial results aimed at better understanding the impact of local oil and gas emissions on regional air quality. Data from the study, along with long-term monitoring data, suggest that while power plants are still an important emissions source in the region, emissions from oil and gas activities are impacting ambient concentrations of nitrogen oxides and black carbon and may dominate recent observed trends in pollutant concentrations at some of the study sites. Measurements of volatile organic compounds also definitively show that oil and gas emissions were present in almost every air mass sampled over a period of more than 4 months.

  17. Headspace vapor characterization of Hanford Waste Tank SX-102: Results from samples collected on July 19, 1995. Tank Vapor Characterization Project

    SciTech Connect

    McVeety, B.D.; Evans, J.C.; Clauss, T.W.; Pool, K.H.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-102 (Tank SX-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed under the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5046. Samples were collected by WHC on July 19, 1995, using the vapor sampling system (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  18. Headspace vapor characterization of Hanford Waste Tank AX-103: Results from samples collected on June 21, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Ligotke, M.W.; Pool, K.H.; Clauss, T.W.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-103 (Tank AX-103) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5029. Samples were collected by WHC on June 21, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  19. Headspace vapor characterization of Hanford Waste Tank 241-S-108: Results from samples collected on December 6, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Thomas, B.L.; Evans, J.C.; McVeety, B.D.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-S-108 (Tank S-108) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5086. Samples were collected by WHC on December 6, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  20. Headspace vapor characterization of Hanford Waste Tank 241-BY-102: Results from samples collected on November 21, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Thomas, B.L.; Evans, J.C.; Pool, K.H.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-BY-102 (Tank BY-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5081. Samples were collected by YMC on November 21, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  1. Headspace vapor characterization of Hanford Waste Tank AX-101: Results from samples collected on June 15, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Pool, K.H.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-101 (Tank AX-101) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) under the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5028. Samples were collected by WHC on June 15, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  2. Headspace vapor characterization of Hanford Waste Tank 241-SX-109: Results from samples collected on August 1, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-109 (Tank SX-109) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5048. Samples were collected by WHC on August 1, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  3. Headspace vapor characterization of Hanford Waste Tank 241-S-112: Results from samples collected on July 11, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Clauss, T.W.; Pool, K.H.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage Tank 241-S-112 (Tank S-112) at the Hanford. Pacific Northwest National Laboratory (PNNL) is contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5044. Samples were collected by WHC on July 11, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  4. Headspace vapor characterization of Hanford Waste Tank 241-SX-105: Results from samples collected on July 26, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-105 (Tank SX-105) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5047. Samples were collected by WHC on July 26, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  5. Headspace vapor characterization of Hanford Waste Tank 241-TX-111: Results from samples collected on October 12, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Pool, K.H.; Clauss, T.W.; Evans, J.C.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-TX-111 (Tank TX-111) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5069. Samples were collected by WHC on October 12, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  6. Headspace vapor characterization of Hanford Waste Tank 241-A-103: Results from samples collected on November 9, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Evans, J.C.; Thomas, B.L.; Pool, K.H.; Olsen, K.B.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-A-103 (Tank A-103) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5073. Samples were collected by WHC on November 9, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  7. Headspace vapor characterization of Hanford Waste Tank 241-BX-107: Results from samples collected on November 17, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Evans, J.C.; Thomas, B.L.; Pool, K.H.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-BX-107 (Tank BX-107) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5080. Samples were collected by WHC on November 17, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  8. Headspace vapor characterization of Hanford Waste Tank 241-SX-104: Results from samples collected on July 25, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Thomas, B.L.; Clauss, T.W.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-104 (Tank SX-104) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5049. Samples were collected by WHC on July 25, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  9. Headspace vapor charterization of Hanford Waste Tank 241-S-110: Results from samples collected on December 5, 1995. Tank Vapor Characterization Project

    SciTech Connect

    Thomas, B.L.; Evans, J.C.; McVeety, B.D.

    1996-06-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-S-110 (Tank S-110) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5085. Samples were collected by WHC on December 5, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  10. Headspace vapor characterization of Hanford Waste Tank 241-T-110: Results from samples collected on August 31, 1995. Tank Vapor Characterization Project

    SciTech Connect

    McVeety, B.D.; Thomas, B.L.; Evans, J.C.

    1996-05-01

    This report describes the results of vapor samples taken from the headspace of waste storage tank 241-T-110 (Tank T-110) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5056. Samples were collected by WHC on August 31, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

  11. EPA's National Dioxin Air Monitoring Network (NDAMN): Design, implementation, and final results

    NASA Astrophysics Data System (ADS)

    Lorber, Matthew; Ferrario, Joseph; Byrne, Christian

    2013-10-01

    The U.S. Environmental Protection Agency (U.S. EPA) established the National Dioxin Air Monitoring Network (NDAMN) in June of 1998, and operated it until November of 2004. The objective of NDAMN was to determine background air concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs). NDAMN started with 10 sampling sites, adding more over time until the final count of 34 sites was reached by the beginning of 2003. Samples were taken quarterly, and the final sample count was 685. All samples were measured for 17 PCDD/PCDF congeners, 8 PCDD/PCDF homologue groups, and 7 dl-PCBs (note: 5 additional dl-PCBs were added for samples starting in the summer of 2002; 317 samples had measurements of 12 dl-PCBs). The overall average total toxic equivalent (TEQ) concentration in the United States was 11.2 fg TEQ m-3 with dl-PCBs contributing 0.8 fg TEQ m-3 (7%) to this total. The archetype dioxin and furan background air congener profile was seen in the survey averages and in most individual samples. This archetype profile is characterized by low and similar concentrations for tetra - through hexa PCDD/PCDF congeners, with elevations in four congeners - a hepta dioxin and furan congener, and both octa congeners. Sites were generally categorized as urban (4 sites), rural (23 sites), or remote (7 sites). The average TEQ concentrations over all sites and samples within these categories were: urban = 15.9 fg TEQ m-3, rural = 13.9 fg TEQ m-3, and remote = 1.2 fg TEQ m-3. Rural sites showed elevations during the fall or winter months when compared to the spring or summer months, and the same might be said for urban sites, but the remote sites appear to show little variation over time. The four highest individual moment measurements were 847, 292, 241, and 132 fg TEQ m-3. For the 847 and 292 fg TEQ m-3 samples, the concentrations of all congeners were elevated over their site averages, but for

  12. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... concentration measured in that sample. If the sample surface concentration is not equal to or lower than...

  13. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... concentration measured in that sample. If the sample surface concentration is not equal to or lower than...

  14. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... concentration measured in that sample. If the sample surface concentration is not equal to or lower than...

  15. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... concentration measured in that sample. If the sample surface concentration is not equal to or lower than...

  16. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... concentration measured in that sample. If the sample surface concentration is not equal to or lower than...

  17. Sampling of power plant stacks for air toxic emissions: Final report for Phases 1 and 2

    SciTech Connect

    1995-04-28

    A test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPs) was conducted . Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical characterization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions. Field testing was conducted in two phases. The Phase I field program was performed over the period of August 24 through September 20, 1992, at the Tennessee Valley Authority Widows Creek Unit 8 Power Station, located near Stevenson (Jackson County), Alabama, on the Tennessee River. Sampling activities for Phase II were conducted from September 11 through October 14, 1993. Widows Creek Unit 8 is a 575-megawatt plant that uses bituminous coal averaging 3.7% sulfur and 13% ash. Downstream of the boiler, a venture wet scrubbing system is used for control of both sulfur dioxide and particulate emissions. There is no electrostatic precipitator (ESP) in this system. This system is atypical and represents only about 5% of the US utility industry. However, this site was chosen for this study because of the lack of information available for this particulate emission control system.

  18. Uncertainties in Air Exchange using Continuous-Injection, Long-Term Sampling Tracer-Gas Methods

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.; Lunden, Melissa M.

    2013-12-01

    The PerFluorocarbon Tracer (PFT) method is a low-cost approach commonly used for measuring air exchange in buildings using tracer gases. It is a specific application of the more general Continuous-Injection, Long-Term Sampling (CILTS) method. The technique is widely used but there has been little work on understanding the uncertainties (both precision and bias) associated with its use, particularly given that it is typically deployed by untrained or lightly trained people to minimize experimental costs. In this article we will conduct a first-principles error analysis to estimate the uncertainties and then compare that analysis to CILTS measurements that were over-sampled, through the use of multiple tracers and emitter and sampler distribution patterns, in three houses. We find that the CILTS method can have an overall uncertainty of 10-15percent in ideal circumstances, but that even in highly controlled field experiments done by trained experimenters expected uncertainties are about 20percent. In addition, there are many field conditions (such as open windows) where CILTS is not likely to provide any quantitative data. Even avoiding the worst situations of assumption violations CILTS should be considered as having a something like a ?factor of two? uncertainty for the broad field trials that it is typically used in. We provide guidance on how to deploy CILTS and design the experiment to minimize uncertainties.

  19. Vapor space characterization of waste tank 241-C-101: Results from samples collected on 9/1/94

    SciTech Connect

    Lucke, R.B.; Clauss, T.W.; Ligotke, M.W.

    1995-11-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-101 (referred to as Tank C-101) and the ambient air collected - 30 ft upwind near the tank and through the VSS near the tank. Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4056, and samples were collected by WHC on September 1, 1994, using the vapor sampling system (VSS). The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated ({le} 10{degrees}C) temperature until the time of analysis. The canisters were stored in the 326/23B laboratory at ambient (25{degrees}C) temperature until the time of the analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for NH{sub 3}, NO{sub 2}, and NO analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS).

  20. Results of monitoring for polychlorinated dibenzo-p-dioxins and dibenzofurans in ambient air at McMurdo station, Antarctica

    SciTech Connect

    Lugar, R.M.; Harles, R.L.

    1996-02-01

    This paper presents the results of ambient air monitoring for polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) performed during the 1992-1993 and 1993-1994 austral summers in the vicinity of McMurdo Station, Antarctica. Twenty-eight air samples were collected from four different locations to determine the identity and concentration of PCDD/PCDF compounds. PCDD/PCDF compounds were not detected at either the predominantly upwind location or a more remote site on Black Island. Trace levels of only a few PCDD/PCDF congeners were detected sporadically at a location approximately 500 m downwind of the station. The most frequent, most varied, and highest levels of PCDDs/PCDFs were measured at a `downtown` location, where concentrations of total PCDDs ranged from 0.12 to 1.80 pg/m{sup 3} and total PCDDs ranged from less than 0.02 to 2.77 pg/m{sup 3}. The data indicate that there are combustion sources at McMurdo other than the solid waste incinerator (power plants, vehicles, heating furnaces, etc.) that contribute PCDD/PCDF compounds to the ambient air. The greatest variety and highest concentration of PCDD/PCDF congeners measured in 1992-1993 during incineration of selected solid wastes implicates the interim incinerator as the likely source of the increased presence of these compounds in air. 18 refs., 2 figs., 3 tabs.

  1. Significance of High-Speed Air Temperature Measurements in the Sampling Cell of a Closed-Path Gas Analyzer with a Short Tube

    NASA Astrophysics Data System (ADS)

    Kathilankal, James; Fratini, Gerardo; Burba, George

    2015-04-01

    Eddy covariance gas analyzers measure gas content in a known volume, thus essentially measuring gas density. The fundamental flux equation, however, is based on the dry mole fraction. The relationship between dry mole fraction and density is regulated by the ideal gas law describing the processes of temperature- and pressure-related expansions and contractions, and by the law of partial pressures, describing the process of dilution. As a result, this relationship depends on water vapor content, temperature and pressure of the air sample. If the instrument is able to output precise high-speed dry mole fraction, the flux processing is significantly simplified and WPL density terms accounting for the air density fluctuations are no longer required. This should also lead to the reduction in uncertainties associated with the density terms resulting from the eddy covariance measurements of sensible and latent heat fluxes used in these terms. In this framework, three main measurement approaches may be considered: Open-path approach Outputting correct high-speed dry mole fraction from the open-path instrument is difficult because of complexities with maintaining reliable fast temperature measurements integrated over the entire measuring path, and also because of extraordinary challenges with accurate measurements of fast pressure in the open air flow. Classical long-tube closed-path approach For instruments utilizing traditional long-tube closed-path design, with tube length 1000 or more times the tube diameter, the fast dry mole fraction can be used successfully when instantaneous fluctuations in the air temperature of the sampled air are effectively dampened to negligible levels, instantaneous pressure fluctuations are regulated or negligible, and water vapor is measured simultaneously with gas or the air sample is dried. Short-tube closed-path approach, the enclosed design For instruments with a short-tube enclosed design, most - but not all - of the temperature

  2. Assessment of respiratory effect of air pollution: study design on general population samples.

    PubMed

    Baldacci, S; Carrozzi, L; Viegi, G; Giuntini, C

    1997-01-01

    The aim of this paper is to describe an epidemiological model to investigate the relationship between respiratory diseases and environmental air pollution. In the Po Delta prospective study, subjects were investigated before and after a large thermoelectric power plant began operating, in 1980 to 1982 and in 1988 to 1991, respectively. The Pisa prospective study was performed in 1986 to 1988 and in 1991 to 1993, before and after the construction of a new expressway that encircles the city from the North to the Southeast. In each survey, subjects completed the interviewer-administered standardized CNR questionnaire on respiratory symptoms/diseases and risk factors, and performed lung function tests. In the second survey of each study, skin prick tests, total serum IgE determination, methacholine challenge test and biomarkers (such as sister chromatide exchanges, micronuclei, chromosomal abnormalities, DNA and hemoglobin adducts) were also performed. Concentrations of total suspended particulate and SO2 in both surveys were higher in urban than in rural areas, as well as symptom/disease prevalences and bronchial reactivity. Subgroups of subjects from the two samples were enrolled to perform a specific study on the acute respiratory effects of indoor pollution; the daily presence of symptoms and measurements of peak expiratory flow (PEF), daily activity pattern, and assessment of the indoor air quality (particulates < 2.5 mu and NO2) were evaluated. Higher symptom prevalences and PEF variability level were observed in subjects with the highest levels of NO2 or particulates, especially asthmatics. In conclusion, these studies represent a basis for further analyses to better define the relationship between respiratory health and indoor/outdoor pollutant levels.

  3. Gasbuggy, New Mexico, Hydrologic and Natural Gas Sampling and Analysis Results for 2009

    SciTech Connect

    2009-11-01

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted hydrologic and natural gas sampling for the Gasbuggy, New Mexico, site on June 16, and 17, 2009. Hydrologic sampling consists of collecting water samples from water wells and surface water locations. Natural gas sampling consists of collecting both gas samples and samples of produced water from gas production wells. The water well samples were analyzed for gamma-emitting radionuclides and tritium. Surface water samples were analyzed for tritium. Water samples from gas production wells were analyzed for gamma-emitting radionuclides, gross alpha, gross beta, and tritium. Natural gas samples were analyzed for tritium and carbon-14. Water samples were analyzed by ALS Laboratory Group in Fort Collins, Colorado, and natural gas samples were analyzed by Isotech Laboratories in Champaign, Illinois. Concentrations of tritium and gamma-emitting radionuclides in water samples collected in the vicinity of the Gasbuggy site continue to demonstrate that the sample locations have not been impacted by detonation-related contaminants. Results from the sampling of natural gas from producing wells demonstrate that the gas wells nearest the Gasbuggy site are not currently impacted by detonation-related contaminants. Annual sampling of the gas production wells nearest the Gasbuggy site for gas and produced water will continue for the foreseeable future. The sampling frequency of water wells and surface water sources in the surrounding area will be reduced to once every 5 years. The next hydrologic sampling event at water wells, springs, and ponds will be in 2014.

  4. Turbine Air-Flow Test Rig CFD Results for Test Matrix

    NASA Technical Reports Server (NTRS)

    Wilson, Josh

    2003-01-01

    This paper presents the Turbine Air-Flow Test (TAFT) rig computational fluid dynamics (CFD) results for test matrix. The topics include: 1) TAFT Background; 2) Design Point CFD; 3) TAFT Test Plan and Test Matrix; and 4) CFD of Test Points. This paper is in viewgraph form.

  5. Waste compatibility safety issues and final results for Tank 241-AP-103 grab samples

    SciTech Connect

    Nuzum, J.L.

    1997-10-02

    Three grab samples (3AP-97-2, 3AP-97-3, and 3AP-97-4) were taken from Riser 1 of Tank 241-AP-103 on August 21, 1997, and received by 222-S Laboratory on August 22, 1997. These samples were analyzed in accordance with Compatibility Grab Sampling and Analysis Plan for Fiscal Year 1997 (TSAP) (Field, 1997) and Data Quality Objectives for Tank Farms Waste and Compatibility Program (Mulkey et. al., 1995) (DQO) in support of the Waste Compatibility Program. No notifications were required based on sample results. Appearance and Sample Breakdown Attachment 1 illustrates subsamples generated in the laboratory for analyses and identifies their sources. Furthermore, this reference relates tank farm identification numbers to their corresponding 222-S Laboratory Information Management System sample numbers. Table 1 summarizes appearance information and over-the-top (OTR) dose readings performed on each sample. For each sample, two 20 ml subsamples were created for inorganic and radiochemical analyses.

  6. Comparison of particle sampling results from tape lifts and solvent rinses

    NASA Astrophysics Data System (ADS)

    Egges, Joanne; Devaud, Genevieve; Rockwell, Christina M.; Matheson, Bruce A.

    2012-10-01

    Historical experience and previously published papers have shown that contamination sampling techniques influence the cleanliness results of spaceflight hardware. Programs rely on this data to show that derived or contractual requirements are met at delivery. Particle sampling using tape lifts and rinses was performed on the James Webb Space Telescope (JWST) Primary Mirror Segment Assemblies (PMSAs) hardware. Sampling was performed on identical hardware with both sampling techniques. The hardware was sampled at comparable stages of assembly which provided hardware with similar levels of particulate contamination. Results from the two sampling techniques are compared. In one technique, sampling was performed by rinsing (with a hand-squeeze bottle with low pressure) followed by a tape lift; the other technique used a tape lift only. The relationship of particle size distribution, types of particles, level of particle contamination, and particle removal rate by sampling technique are examined. Comparison of the particle sampling results provides a basis for interpreting results depending on sampling techniques. Improving the contamination engineer's ability to interpret results is particularly useful when hardware configuration or surface finish dictate which sampling technique can be used. When one can choose the sampling technique, the results of this study can provide guidance on which technique is more appropriate depending on the circumstances. Results show that tape lifts remove more particles than low pressure rinses; furthermore that tape lift only is better than the combined operation of a rinse closely followed by a tape lift. Results also indicate that further work should be performed on different surface finishes, rinsing techniques, and particulate contamination levels.

  7. Vapor space characterization of waste tank 241-BY-107: Results from samples collected on 10/26/94

    SciTech Connect

    Clauss, T.W.; Ligotke, M.W.; Pool, K.H.

    1995-10-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-107 (referred to as Tank BY-107). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The organic analytes for TO-14 compounds were extended to include 15 analytes identified by the Toxicological Review Panel for Tank C-103 and reported in Toxicological Evaluation of Analytes from Tank 241-C-103 PAE-10189. While these analytes are only of toxicological concern for Tank C-103, program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T. J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.5. The sample job was designated S4077, and samples were collected by WHC on October 26, 1994, using the vapor sampling system (VSS). Sampling devices, including six sorbent trains (for inorganic analyses), and six SUMMA{trademark} canisters (for organic analyses) were supplied to the WHC sampling staff on October 24. Samples were taken (by WHC) from the tank headspace on October 26 and were returned to PNL from the field on November 8. Inorganic (sorbent trap) samples were delivered to PNL on chain of custody (COC) 008071. The SUMMA{trademark} canisters were delivered on COC 008070. Three SUMMA{trademark} canister samples were stored at the PNL 326/23B laboratory pending further instruction from WHC to send them to the Oregon Graduate Institute (OGI) for analysis.

  8. Vapor space characterization of waste tank 241-C-109: Results from samples collected on 8/10/94

    SciTech Connect

    Pool, K.H.; Clauss, T.W.; Ligotke, M.W.

    1995-06-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-109 (referred to as Tank C-109). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4053, and samples were collected by WHC on August 10, 1994, using the vapor sampling system (VSS). Sampling devices, including six sorbent trains (for inorganic analyses) and five SUMMA{sup {trademark}} canisters (for organic analyses) were supplied to the WHC sampling staff on August 8. Samples were taken (by WHC) from the tank headspace on August 10 and were returned to PNL from the field on August 12. The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated ({<=}10{degrees}C) temperature until the time of analysis. The canister was stored in the 326/23B laboratory at ambient (25{degrees}C) temperature until time of analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for ammonia (NH{sub 3}) or nitrite (NO{sub 2}) analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS).

  9. Analytical method validation for the determination of 2,3,3,3-tetrafluoropropene in air samples using gas chromatography with flame ionization detection.

    PubMed

    Mawn, Michael P; Kurtz, Kristine; Stahl, Deborah; Chalfant, Richard L; Koban, Mary E; Dawson, Barbara J

    2013-01-01

    A new low global warming refrigerant, 2,3,3,3-tetrafluoro propene, or HFO-1234yf, has been successfully evaluated for automotive air conditioning, and is also being evaluated for stationary refrigeration and air conditioning systems. Due to the advantageous environmental properties of HFO-1234yf versus HFC-134a, coupled with its similar physical properties and system performance, HFO-1234yf is also being evaluated to replace HFC-134a in refrigeration applications where neat HFC-134a is currently used. This study reports on the development and validation of a sampling and analytical method for the determination of HFO-1234yf in air. Different collection media were screened for desorption and simulated sampling efficiency with three-section (350/350/350 mg) Anasorb CSC showing the best results. Therefore, air samples were collected using two 3-section Anasorb CSC sorbent tubes in series at 0.02 L/min for up to 8 hr for sample volumes of up to 9.6 L. The sorbent tubes were extracted in methylene chloride, and analyzed by gas chromatography with flame ionization detection. The method was validated from 0.1× to 20× the target level of 0.5 ppm (2.3 mg/m(3)) for a 9.6 L air volume. Desorption efficiencies for HFO-1234yf were 88 to 109% for all replicates over the validation range with a mean overall recovery of 93%. Simulated sampling efficiencies ranged from 87 to 104% with a mean of 94%. No migration or breakthrough to the back tube was observed under the sampling conditions evaluated. HFO-1234yf samples showed acceptable storage stability on Anasorb CSC sorbent up to a period of 30 days when stored under ambient, refrigerated, or frozen temperature conditions.

  10. Waste compatibility safety issues and final results for tank 241-SY-102 grab samples

    SciTech Connect

    Nuzum, J.L.

    1997-08-14

    Three grab samples (2SY-96-1, 2SY-96-2, and 2SY-96-3) were taken from Riser 1A of Tank 241-SY 102 on January 14, 1997, and received by 222-S Laboratory on January 14, 1997. These samples were analyzed in accordance with Compatibility Grab Sampling and Analysis Plan (TSAP) and Data Quality Objectives for Tank Farm Waste Compatibility Program (DQO) in support of the Waste Compatibility Program. No notifications were required based on sample results. Acetone analysis was not performed in accordance with Cancellation of Acetone Analysis for Tank 241-SY-102 Grab Samples.

  11. Results from CrIS-ATMS Obtained Using the AIRS Science Team Retrieval Methodology

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis C.; Iredell, Lena

    2013-01-01

    which significantly improved results of AIRS Version-6. Version-5.70 CrIS/ATMS temperature profile and surface skin temperature retrievals are of very good quality, and are better than AIRS Version-5 retrievals, but are still significantly poorer than those of AIRS Version-6. CrIS/ATMS retrievals should improve when a Neural-Net start-up system is ready for use. We also examined CrIS/ATMS retrievals generated by NOAA using their NUCAPS retrieval algorithm, which is based on earlier versions of the AIRS Science Team retrieval algorithms. We show that the NUCAPS algorithm as currently configured is not well suited for climate monitoring purposes.

  12. Day and night variation in chemical composition and toxicological responses of size segregated urban air PM samples in a high air pollution situation

    NASA Astrophysics Data System (ADS)

    Jalava, P. I.; Wang, Q.; Kuuspalo, K.; Ruusunen, J.; Hao, L.; Fang, D.; Väisänen, O.; Ruuskanen, A.; Sippula, O.; Happo, M. S.; Uski, O.; Kasurinen, S.; Torvela, T.; Koponen, H.; Lehtinen, K. E. J.; Komppula, M.; Gu, C.; Jokiniemi, J.; Hirvonen, M.-R.

    2015-11-01

    Urban air particulate pollution is a known cause for adverse human health effects worldwide. China has encountered air quality problems in recent years due to rapid industrialization. Toxicological effects induced by particulate air pollution vary with particle sizes and season. However, it is not known how distinctively different photochemical activity and different emission sources during the day and the night affect the chemical composition of the PM size ranges and subsequently how it is reflected to the toxicological properties of the PM exposures. The particulate matter (PM) samples were collected in four different size ranges (PM10-2.5; PM2.5-1; PM1-0.2 and PM0.2) with a high volume cascade impactor. The PM samples were extracted with methanol, dried and thereafter used in the chemical and toxicological analyses. RAW264.7 macrophages were exposed to the particulate samples in four different doses for 24 h. Cytotoxicity, inflammatory parameters, cell cycle and genotoxicity were measured after exposure of the cells to particulate samples. Particles were characterized for their chemical composition, including ions, element and PAH compounds, and transmission electron microscopy (TEM) was used to take images of the PM samples. Chemical composition and the induced toxicological responses of the size segregated PM samples showed considerable size dependent differences as well as day to night variation. The PM10-2.5 and the PM0.2 samples had the highest inflammatory potency among the size ranges. Instead, almost all the PM samples were equally cytotoxic and only minor differences were seen in genotoxicity and cell cycle effects. Overall, the PM0.2 samples had the highest toxic potential among the different size ranges in many parameters. PAH compounds in the samples and were generally more abundant during the night than the day, indicating possible photo-oxidation of the PAH compounds due to solar radiation. This was reflected to different toxicity in the PM

  13. Potential contamination of shipboard air samples by diffusive emissions of PCBs and other organic pollutants: implications and solutions.

    PubMed

    Lohmann, Rainer; Jaward, Foday M; Durham, Louise; Barber, Jonathan L; Ockenden, Wendy; Jones, Kevin C; Bruhn, Regina; Lakaschus, Soenke; Dachs, Jordi; Booij, Kees

    2004-07-15

    Air samples were taken onboard the RRS Bransfield on an Atlantic cruise from the United Kingdom to Halley, Antarctica, from October to December 1998, with the aim of establishing PCB oceanic background air concentrations and assessing their latitudinal distribution. Great care was taken to minimize pre- and post-collection contamination of the samples, which was validated through stringent QA/QC procedures. However, there is evidence that onboard contamination of the air samples occurred,following insidious, diffusive emissions on the ship. Other data (for PCBs and other persistent organic pollutants (POPs)) and examples of shipboard contamination are presented. The implications of these findings for past and future studies of global POPs distribution are discussed. Recommendations are made to help critically appraise and minimize the problems of insidious/diffusive shipboard contamination.

  14. The classification of the patients with pulmonary diseases using breath air samples spectral analysis

    NASA Astrophysics Data System (ADS)

    Kistenev, Yury V.; Borisov, Alexey V.; Kuzmin, Dmitry A.; Bulanova, Anna A.

    2016-08-01

    Technique of exhaled breath sampling is discussed. The procedure of wavelength auto-calibration is proposed and tested. Comparison of the experimental data with the model absorption spectra of 5% CO2 is conducted. The classification results of three study groups obtained by using support vector machine and principal component analysis methods are presented.

  15. Aqueous photooxidation of ambient Po Valley Italy air samples: Insights into secondary organic aerosol formation

    NASA Astrophysics Data System (ADS)

    Kirkland, J. R.; Lim, Y. B.; Sullivan, A. P.; Decesari, S.; Facchini, C.; Collett, J. L.; Keutsch, F. N.; Turpin, B. J.

    2012-12-01

    In this work, we conducted aqueous photooxidation experiments with ambient samples in order to develop insights concerning the formation of secondary organic aerosol through gas followed by aqueous chemistry (SOAaq). Water-soluble organics (e.g., glyoxal, methylglyoxal, glycolaldehyde, acetic acid, acetone) are formed through gas phase oxidation of alkene and aromatic emissions of anthropogenic and biogenic origin. Their further oxidation in clouds, fogs and wet aerosols can form lower volatility products (e.g., oligomers, organic acids) that remain in the particle phase after water evaporation, thus producing SOA. The aqueous OH radical oxidation of several individual potentially important precursors has been studied in the laboratory. In this work, we used a mist-chamber apparatus to collect atmospheric mixtures of water-soluble gases from the ambient air at San Pietro Capofiume, Italy during the PEGASOS field campaign. We measured the concentration dynamics after addition of OH radicals, in order to develop new insights regarding formation of SOA through aqueous chemistry. Specifically, batch aqueous reactions were conducted with 33 ml mist-chamber samples (TOC ~ 50-100μM) and OH radicals (~10-12M) in a new low-volume aqueous reaction vessel. OH radicals were formed in-situ, continuously by H2O2 photolysis. Products were analyzed by ion chromatography (IC), electrospray ionization mass spectrometry (ESI-MS +/-), and ESI-MS with IC pre-separation (IC/ESI-MS-). Reproducible formation of pyruvate and oxalate were observed both by IC and ESI-MS. These compounds are known to form from aldehyde oxidation in the aqueous phase. New insights regarding the aqueous chemistry of these "more atmospherically-realistic" experiments will be discussed.

  16. Ice nucleation active particles in continental air samples over Mainz, Germany

    NASA Astrophysics Data System (ADS)

    Pummer, Bernhard G.; Pöschl, Ulrich; Fröhlich-Nowoisky, Janine

    2016-04-01

    Aerosol particles are of central importance for atmospheric chemistry and physics, climate and public health. Some of these particles possess ice nucleation activity (INA), which is highly relevant for cloud formation and precipitation. In 2010, air filter samples were collected with a high-volume filter sampler separating fine and coarse particles (aerodynamic cut-off diameter 3 μm) in Mainz, Germany. In this study, the INA of the atmospheric particles deposited on these filters was determined. Therefore,they were extracted with ultrapure water, which was then measured in a droplet freezing assay, as described in Fröhlich-Nowoisky et al. (2015). The determined concentration of ice nucleators (INs) was between 0.3 and 2per m³ at 266 K, and between5 and 75 per m³ at 260 K. The INs were further characterized by different treatments, like heating (308 K, 371 K), filtration (0.1 μm, 300 kDa), and digestion with papain (10 mg/ml). We further investigated, which atmospheric conditions (e.g. weather) and distinguished events (e.g. dust storms, volcanic eruptions, and pollen peaks) influenced the number and nature of these INs. Fröhlich-Nowoisky, J., Hill, T. C. J., Pummer, B. G., Yordanova, P., Franc, G. D., and Pöschl, U.: Ice nucleation activity in the widespread soil fungus Mortierella alpina, Biogeosci., 12, 1057-1071, doi:10.5194/bg-12-1057-2015, 2015.

  17. Vapor space characterization of waste Tank 241-BY-111: Results from samples collected on November 15, 1994

    SciTech Connect

    Lucke, R.B.; Ligotke, M.W.; McVeety, B.D.

    1995-06-01

    This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-111 (referred to as Tank By-111). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The target analytes for TO- 14 compounds were extended to include 14 analytes identified by the Toxicological Review Panel for Tank C-103 and reported by Mahlum et al. (1994). Program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T.J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.7. The sample job was designated S4083, and samples wee collected by WHC on November 16, 1994, using the vapor sampling system (VSS). The results of the analyses are expected to be used to estimate the potential toxicity of tank-headspace gas as described in Data Quality Objectives for Generic In-Tank Health and Safety Vapor Issue Resolution, WHC-SD-WM-DQO-002, Rev. 0.

  18. [Implementation results of emission standards of air pollutants for thermal power plants: a numerical simulation].

    PubMed

    Wang, Zhan-Shan; Pan, Li-Bo

    2014-03-01

    The emission inventory of air pollutants from the thermal power plants in the year of 2010 was set up. Based on the inventory, the air quality of the prediction scenarios by implementation of both 2003-version emission standard and the new emission standard were simulated using Models-3/CMAQ. The concentrations of NO2, SO2, and PM2.5, and the deposition of nitrogen and sulfur in the year of 2015 and 2020 were predicted to investigate the regional air quality improvement by the new emission standard. The results showed that the new emission standard could effectively improve the air quality in China. Compared with the implementation results of the 2003-version emission standard, by 2015 and 2020, the area with NO2 concentration higher than the emission standard would be reduced by 53.9% and 55.2%, the area with SO2 concentration higher than the emission standard would be reduced by 40.0%, the area with nitrogen deposition higher than 1.0 t x km(-2) would be reduced by 75.4% and 77.9%, and the area with sulfur deposition higher than 1.6 t x km(-2) would be reduced by 37.1% and 34.3%, respectively.

  19. In situ detection of lung cancer volatile fingerprints using bronchoscopic air-sampling.

    PubMed

    Santonico, M; Lucantoni, G; Pennazza, G; Capuano, R; Galluccio, G; Roscioni, C; La Delfa, G; Consoli, D; Martinelli, E; Paolesse, R; Di Natale, C; D'Amico, A

    2012-07-01

    Lung cancer diagnosis via breath analysis has to overcome some issues that can be summarized by two crucial points: (1) further developments for more performant breath sampling technologies; (2) discovering more differentiated volatile fingerprints to be ascribed to specific altered biological mechanisms. The present work merges these two aspects in a pilot study, where a breath volume, sampled via endoscopic probe, is analyzed by an array of non-selective gas sensors. Even if the original non-invasive methods of breath analysis has been laid in favour of the endoscopic means, the innovative technique here proposed allows the analysis of the volatile mixtures directly sampled near the tumor mass. This strategy could open the way for a better understanding of the already obtained discrimination among positive and negative cancer cases. The results obtained so far confirm the established discrimination capacity. This allows to discriminate the different subtypes of lung cancer with 75% of correct classification between adenocarcinoma and squamous cell carcinoma. This result suggests that a 'zoom-in' on the cancer settled inside the human body can increase the resolution power of key-volatiles detection, allowing the discrimination among different cancer fingerprints. We report this novel technique as a robust support for a better comprehension of the promising results obtained so far and present in literature; it is not to be intended as a replacement for non-invasive breath sampling procedure with the endoscope.

  20. Results of Analyses of Tank 37H Criticality Salt Samples (HTK-493 and 494)

    SciTech Connect

    Swingle, R.F.

    2002-07-10

    High Level Waste Division (HLWD) personnel requested Savannah River Technology Center (SRTC) support in analyzing samples of salt cake from Tank 37H as input to a Nuclear Criticality Safety Evaluation (NCSE) in support of dissolution of the salt in the tank. Two salt core samples (HTK-493 and 494) were pulled from Tank 37H and transferred to the SRTC Shielded Cells Facility on April 2, 2002 for analyses of species that may affect criticality as the salt is dissolved. The core samples were composited and prepared for analysis of the as-received sample and of insoluble solids separated from as-received sample. Results of the analyses are presented herein. Results are given for the as-received salt cake, for insoluble solids separated from the core sample both with and without a correction for soluble solids remaining after dissolution, and for wash water produced by dissolving the soluble salts in inhibited water.

  1. Auditing of sampling methods for air toxics at coal-fired power plants

    SciTech Connect

    Agbede, R.O.; Clements, J.L.; Grunebach, M.G.

    1995-11-01

    Advanced Technology Systems, Inc. (ATS) with subcontract assistance from international Technology Corporation (IT) has provided external audit activities for Phase II of the Department of Energy-Pittsburgh Energy Technology Center`s air emission test program. The objective of the audits is to help ensure that the data obtained from the emission tests are precise, accurate, representative, scientifically sound and legally defensible. This paper presents the criteria that were used to perform the external audits of the emission test program. It also describes the approach used by ATS and It in performing their audits. Examples of findings of the audits along with the actions take to correct problems and the subsequent effect of those actions on the test data are presented. The results of audit spikes performed at the Plant 1 test site are also discussed.

  2. Results of 1.0-L sample bottle pressurization tests for the pit burst experiment

    SciTech Connect

    Veirs, K.D.; Prenger, F.C.; Harradine, D.M.; McFarlan, J.T.

    1997-02-01

    Pressurization tests were performed on a 1.0-L sample bottle to verify operational aspects of the pit burst experimental test apparatus. The 1.0-L sample bottle was selected because of its known geometry, certified performance and ready availability. Redundant strain gage instrumentation was installed on the test sample enabling evaluation of the repeatability and consistency of data acquisition. Test results were compared with analytical model predictions to evaluate instrumentation accuracy.

  3. An analytical method for trifluoroacetic Acid in water and air samples using headspace gas chromatographic determination of the methyl ester.

    PubMed

    Zehavi, D; Seiber, J N

    1996-10-01

    An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA. PMID:21619278

  4. Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

    PubMed

    Normand, Anne-Cécile; Ranque, Stéphane; Cassagne, Carole; Gaudart, Jean; Sallah, Kankoé; Charpin, Denis-André; Piarroux, Renaud

    2016-03-01

    Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments.

  5. Estimating sampling biases and measurement uncertainties of AIRS/AMSU-A temperature and water vapor observations using MERRA reanalysis

    NASA Astrophysics Data System (ADS)

    Hearty, Thomas J.; Savtchenko, Andrey; Tian, Baijun; Fetzer, Eric; Yung, Yuk L.; Theobald, Michael; Vollmer, Bruce; Fishbein, Evan; Won, Young-In

    2014-03-01

    We use MERRA (Modern Era Retrospective-Analysis for Research Applications) temperature and water vapor data to estimate the sampling biases of climatologies derived from the AIRS/AMSU-A (Atmospheric Infrared Sounder/Advanced Microwave Sounding Unit-A) suite of instruments. We separate the total sampling bias into temporal and instrumental components. The temporal component is caused by the AIRS/AMSU-A orbit and swath that are not able to sample all of time and space. The instrumental component is caused by scenes that prevent successful retrievals. The temporal sampling biases are generally smaller than the instrumental sampling biases except in regions with large diurnal variations, such as the boundary layer, where the temporal sampling biases of temperature can be ± 2 K and water vapor can be 10% wet. The instrumental sampling biases are the main contributor to the total sampling biases and are mainly caused by clouds. They are up to 2 K cold and > 30% dry over midlatitude storm tracks and tropical deep convective cloudy regions and up to 20% wet over stratus regions. However, other factors such as surface emissivity and temperature can also influence the instrumental sampling bias over deserts where the biases can be up to 1 K cold and 10% wet. Some instrumental sampling biases can vary seasonally and/or diurnally. We also estimate the combined measurement uncertainties of temperature and water vapor from AIRS/AMSU-A and MERRA by comparing similarly sampled climatologies from both data sets. The measurement differences are often larger than the sampling biases and have longitudinal variations.

  6. Estimating Sampling Biases and Measurement Uncertainties of AIRS-AMSU-A Temperature and Water Vapor Observations Using MERRA Reanalysis

    NASA Technical Reports Server (NTRS)

    Hearty, Thomas J.; Savtchenko, Andrey K.; Tian, Baijun; Fetzer, Eric; Yung, Yuk L.; Theobald, Michael; Vollmer, Bruce; Fishbein, Evan; Won, Young-In

    2014-01-01

    We use MERRA (Modern Era Retrospective-Analysis for Research Applications) temperature and water vapor data to estimate the sampling biases of climatologies derived from the AIRS/AMSU-A (Atmospheric Infrared Sounder/Advanced Microwave Sounding Unit-A) suite of instruments. We separate the total sampling bias into temporal and instrumental components. The temporal component is caused by the AIRS/AMSU-A orbit and swath that are not able to sample all of time and space. The instrumental component is caused by scenes that prevent successful retrievals. The temporal sampling biases are generally smaller than the instrumental sampling biases except in regions with large diurnal variations, such as the boundary layer, where the temporal sampling biases of temperature can be +/- 2 K and water vapor can be 10% wet. The instrumental sampling biases are the main contributor to the total sampling biases and are mainly caused by clouds. They are up to 2 K cold and greater than 30% dry over mid-latitude storm tracks and tropical deep convective cloudy regions and up to 20% wet over stratus regions. However, other factors such as surface emissivity and temperature can also influence the instrumental sampling bias over deserts where the biases can be up to 1 K cold and 10% wet. Some instrumental sampling biases can vary seasonally and/or diurnally. We also estimate the combined measurement uncertainties of temperature and water vapor from AIRS/AMSU-A and MERRA by comparing similarly sampled climatologies from both data sets. The measurement differences are often larger than the sampling biases and have longitudinal variations.

  7. Recent Results of the Investigation of a Microfluidic Sampling Chip and Sampling System for Hot Cell Aqueous Processing Streams

    SciTech Connect

    Julia Tripp; Jack Law; Tara Smith

    2013-10-01

    A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and microfluidics sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The microfluidic-based robotic sampling system’s mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of microfluidic sampling chips.

  8. RESULTS OF INITIAL ANALYSES OF THE MACROBATCH 5 TANK 21H QUALIFICATION SAMPLES

    SciTech Connect

    Peters, T.; Fink, S.

    2012-01-31

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Salt (Macro)Batch 5 for the Integrated Salt Disposition Project (ISDP). This document reports the initial results of the analyses of samples of Tank 21H. No issues with the projected Salt Batch 5 strategy are identified. This report describes the laboratory results of Salt (Macro)Batch 5 preliminary samples from Tank 21H. These results will be used by Tank Farm Engineering for their blend calculations. This work was specified by Technical Task Request (TTR) and by Task Technical and Quality Assurance Plan (TTQAP).

  9. Analytical Results from the Area G Nitrate Salt Samples Submitted to C-AAC

    SciTech Connect

    Drake, Lawrence Randall

    2014-09-03

    Table 1 is a summary of the analysis results on sample 4174-1-6/7 and 4174-2-6/7. The results in Table 2 are the major and trace metals analysis values. Samples 4174-1-6 and 4174-2-7 were introduced into a radiological glovebox in CMR for partitioning and analysis. Samples 4174-1-7 and 4174-2-6 were assayed by gamma spectrometry and then sent to TA 48 (C-NR) for further analysis. The validated analytical procedures used by C-AAC are cited at the end of this document. The results have not been approved by formal QA release.

  10. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Decisions based on PCB concentration....61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For grid samples which are chemically analyzed individually, the PCB concentration applies to the area...

  11. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Decisions based on PCB concentration....61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For grid samples which are chemically analyzed individually, the PCB concentration applies to the area...

  12. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Decisions based on PCB concentration....61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For grid samples which are chemically analyzed individually, the PCB concentration applies to the area...

  13. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Decisions based on PCB concentration....61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For grid samples which are chemically analyzed individually, the PCB concentration applies to the area...

  14. B Plant canyon sample TK-21-1 analytical results for the final report

    SciTech Connect

    Steen, F.H.

    1998-04-10

    This document is the analytical laboratory report for the TK-21-1 sample collected from the B Plant Canyon on February 18, 1998. The sample was analyzed in accordance with the Sampling and Analysis Plan for B Plant Solutions (SAP) (Simmons, 1997) in support of the B Plant decommissioning project. Samples were analyzed to provide data both to describe the material which would remain in the tanks after the B Plant transition is complete and to determine Tank Farm compatibility. The analytical results are included in the data summary table (Table 1).

  15. 60-Day waste compatibility safety issues and final results for AY-102 grab samples

    SciTech Connect

    Nuzum, J.L.

    1997-01-31

    Four grab samples (2AY-96-15, 2AY-96-16, 2AY-96-17, and 2AY-96-18) were taken from Riser 15D of Tank 241-AY-102 on October 8, 1996, and received by 222-S Laboratory on October 8, 1996. These samples were analyzed in accordance with Compatibility Grab Sampling and Analysis Plan (TSAP) and Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO) in support of the Waste Compatibility Program. No notifications were required based on sample results.

  16. Interim results from UO/sub 2/ fuel oxidation tests in air

    SciTech Connect

    Campbell, T.K.; Gilbert, E.R.; Thornhill, C.K.; White, G.D.; Piepel, G.F.; Griffin, C.W.j

    1987-08-01

    An experimental program is being conducted at Pacific Northwest Laboratory (PNL) to extend the characterization of spent fuel oxidation in air. To characterize oxidation behavior of irradiated UO/sub 2/, fuel oxidation tests were performed on declad light-water reactor spent fuel and nonirradited UO/sub 2/ pellets in the temperature range of 135 to 250/sup 0/C. These tests were designed to determine the important independent variables that might affect spent fuel oxidation behavior. The data from this program, when combined with the test results from other programs, will be used to develop recommended spent fuel dry-storage temperature limits in air. This report describes interim test results. The initial PNL investigations of nonirradiated and spent fuels identified the important testing variables as temperature, fuel burnup, radiolysis of the air, fuel microstructure, and moisture in the air. Based on these initial results, a more extensive statistically designed test matrix was developed to study the effects of temperature, burnup, and moisture on the oxidation behavior of spent fuel. Oxidation tests were initiated using both boiling-water reactor and pressurized-water reactor fuels from several different reactors with burnups from 8 to 34 GWd/MTU. A 10/sup 5/ R/h gamma field was applied to the test ovens to simulate dry storage cask conditions. Nonirradiated fuel was included as a control. This report describes experimental results from the initial tests on both the spent and nonirradiated fuels and results to date on the tests in a 10/sup 5/ R/h gamma field. 33 refs., 51 figs., 6 tabs.

  17. Saturation sampling for spatial variation in multiple air pollutants across an inversion-prone metropolitan area of complex terrain

    PubMed Central

    2014-01-01

    Background Characterizing intra-urban variation in air quality is important for epidemiological investigation of health outcomes and disparities. To date, however, few studies have been designed to capture spatial variation during select hours of the day, or to examine the roles of meteorology and complex terrain in shaping intra-urban exposure gradients. Methods We designed a spatial saturation monitoring study to target local air pollution sources, and to understand the role of topography and temperature inversions on fine-scale pollution variation by systematically allocating sampling locations across gradients in key local emissions sources (vehicle traffic, industrial facilities) and topography (elevation) in the Pittsburgh area. Street-level integrated samples of fine particulate matter (PM2.5), black carbon (BC), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3) were collected during morning rush and probable inversion hours (6-11 AM), during summer and winter. We hypothesized that pollution concentrations would be: 1) higher under inversion conditions, 2) exacerbated in lower-elevation areas, and 3) vary by season. Results During July - August 2011 and January - March 2012, we observed wide spatial and seasonal variability in pollution concentrations, exceeding the range measured at regulatory monitors. We identified elevated concentrations of multiple pollutants at lower-elevation sites, and a positive association between inversion frequency and NO2 concentration. We examined temporal adjustment methods for deriving seasonal concentration estimates, and found that the appropriate reference temporal trend differs between pollutants. Conclusions Our time-stratified spatial saturation approach found some evidence for modification of inversion-concentration relationships by topography, and provided useful insights for refining and interpreting GIS-based pollution source indicators for Land Use Regression modeling. PMID:24735818

  18. Assessment of the Impact of Spatial Data on the Results of Air Pollution Dispersion Modeling

    NASA Astrophysics Data System (ADS)

    Oleniacz, Robert; Rzeszutek, Mateusz

    2014-12-01

    Advanced dispersion models, taking into account information on the relief and land cover, as well as temporal and spatial variability of meteorological conditions, are beginning to play an increasingly important role in the assessment of the impact on the air quality. There are numerous spatial databases which can be used in this type of a calculation process, however, there is no answer to the question of how the use of appropriate data set of terrain characteristics affects the results of the distribution of air pollutant concentrations at the surface of the ground. This paper presents two different sets of spatial data of the relief and land cover. Then, their impact on the results of modeling the propagation of pollutants in the ambient air was characterized, using the meteorological processor CALMET and the dispersion model CALPUFF. The obtained results of concentrations in the adopted calculation area were compared on the basis of statistical indicators used to assess pollution dispersion models contained in the statistical package BOOT Statistical Model Evaluation Software Package Version 2.0. The obtained results of calculations of the maximum 1-hour concentrations, the maximum 24-hour mean concentrations and annual mean concentrations for the prepared computational grids with a resolution of 1×1 km were analyzed.

  19. Practical considerations for the interpretation of microbial testing results based on small numbers of samples.

    PubMed

    Hoelzer, Karin; Pouillot, Régis

    2013-11-01

    While adequate, statistically designed sampling plans should be used whenever feasible, inference about the presence of pathogens in food occasionally has to be made based on smaller numbers of samples. To help the interpretation of such results, we reviewed the impact of small sample sizes on pathogen detection and prevalence estimation. In particular, we evaluated four situations commonly encountered in practice. The first two examples evaluate the combined impact of sample size and pathogen prevalence (i.e., fraction of contaminated food items in a given lot) on pathogen detection and prevalence estimation. The latter two examples extend the previous example to consider the impact of pathogen concentration and imperfect test sensitivity. The provided examples highlight the difficulties of making inference based on small numbers of samples, and emphasize the importance of using appropriate statistical sampling designs whenever possible.

  20. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... installation; (and/or) Processing this FOIA request will require us to collect and review a substantial number... documents might be responsive to your request. Please give us whatever additional details you may have on the Air Force records you want. Can you tell us when the records were created, and what Air...

  1. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... installation; (and/or) Processing this FOIA request will require us to collect and review a substantial number... documents might be responsive to your request. Please give us whatever additional details you may have on the Air Force records you want. Can you tell us when the records were created, and what Air...

  2. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... installation; (and/or) Processing this FOIA request will require us to collect and review a substantial number... documents might be responsive to your request. Please give us whatever additional details you may have on the Air Force records you want. Can you tell us when the records were created, and what Air...

  3. It's Alive!: Students Observe Air-Water Interface Samples Rich with Organisms

    ERIC Educational Resources Information Center

    Avant, Thomas

    2002-01-01

    This article describes an experiment, designed by Cindy Henk, manager of the Socolofsky Microscopy Center at Louisiana State University (LSU), that involved collecting and viewing microorganisms in the air-water interface. The experiment was participated by Leesville High School microbiology students. The students found that the air-water…

  4. Vapor space characterization of waste Tank 241-BY-103: Results from samples collected on 11/1/94

    SciTech Connect

    McVeety, B.D.; Klinger, G.S.; Clauss, T.W.

    1995-10-01

    This report describes inorganic and organic analyses results from samples obtained from the headspace of the Hanford waste storage Tank 241-BY-103 (referred to as Tank BY-103). The results described here were obtained to support safety and toxicological evaluations. A summary of the results for inorganic and organic analytes is listed in Table 1. Detailed descriptions of the results appear in the text. Quantitative results were obtained for the inorganic compounds ammonia (NH{sub 3}), nitrogen dioxide (NO{sub 2}), nitric oxide (NO), and water (H{sub 2}O). Trends in NH{sub 3} and H{sub 2}O samples indicated a possible minor sampling problem. Sampling for hydrogen cyanide (HCN) and sulfur oxides (SO{sub x}) was not requested. In addition, quantitative results were obtained for target organic analytes, 39 TO-14 compounds, plus an additional 14 analytes. Of these, four were observed above the 5-ppbv reporting cutoff. Fourteen organic tentatively identified compounds (TICs) were observed above the reporting cutoff of (ca.) 10 ppbv, and are reported with concentrations that are semiquantitative estimates based on internal-standard response factors. The 10 organic analytes with the highest estimated concentrations are listed in Table 1 and account for approximately 88% of the total organic components in Tank BY-103. Two permanent gases, carbon dioxide (CO{sub 2}) and nitrous oxide (N{sub 2}O), were also detected in the tank headspace. Carbon monoxide (CO) and carbon dioxide (CO{sub 2}) were detected in the ambient air sample. Tank BY-103 is on the Ferrocyanide Watch List.

  5. Tank 214-AW-105, grab samples, analytical results for the finalreport

    SciTech Connect

    Esch, R.A.

    1997-02-20

    This document is the final report for tank 241-AW-105 grab samples. Twenty grabs samples were collected from risers 10A and 15A on August 20 and 21, 1996, of which eight were designated for the K Basin sludge compatibility and mixing studies. This document presents the analytical results for the remaining twelve samples. Analyses were performed in accordance with the Compatibility Grab Sampling and Analysis Plan (TSAP) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DO). The results for the previous sampling of this tank were reported in WHC-SD-WM-DP-149, Rev. 0, 60-Day Waste Compatibility Safety Issue and Final Results for Tank 241-A W-105, Grab Samples 5A W-95-1, 5A W-95-2 and 5A W-95-3. Three supernate samples exceeded the TOC notification limit (30,000 microg C/g dry weight). Appropriate notifications were made. No immediate notifications were required for any other analyte. The TSAP requested analyses for polychlorinated biphenyls (PCB) for all liquids and centrifuged solid subsamples. The PCB analysis of the liquid samples has been delayed and will be presented in a revision to this document.

  6. Development of a combined air sampling and quantitative real-time PCR method for detection of Legionella spp.

    PubMed

    Sirigul, Chomrach; Wongwit, Waranya; Phanprasit, Wantanee; Paveenkittiporn, Wantana; Blacksell, Stuart D; Ramasoota, Pongrama

    2006-05-01

    The objective of this study was to develop and optimize the combined methods of air sampling and real time polymerase chain reaction (real-time PCR) for quantifying aerosol Legionella spp. Primers and TaqMan hydrolysis probe based on 5S rRNA gene specific for Legionella spp were used to amplify a specific DNA product of 84 bp. The impinger air sampler plus T-100 sampling pump was used to collect aerosol Legionella and as low as 10 fg of Legionella DNA per reaction could detected. Preliminary studies demonstrated that the developed method could detect aerosol Legionella spp 1.5-185 organisms /500 l of air within 5 hours, in contrast to culture method, that required a minimum of 7-10 days. PMID:17120970

  7. Analysis of 129I in Groundwater Samples: Direct and Quantitative Results below the Drinking Water Standard

    SciTech Connect

    Brown, Christopher F.; Geiszler, Keith N.; Lindberg, Michael J.

    2007-03-03

    Due to its long half-life (15.7 million years) and relatively unencumbered migration in subsurface environments, 129I has been recognized as a contaminant of concern at numerous federal, private, and international facilities. In order to understand the long-term risk associated with 129I at these locations, quantitative analysis of groundwater samples must be performed. However, the ability to quantitatively assess the 129I content in groundwater samples requires specialized extraction and sophisticated analytical techniques, which are complicated and not always available to the general scientific community. This paper highlights an analytical method capable of directly quantifying 129I in groundwater samples at concentrations below the MCL without the need for sample pre-concentration. Samples were analyzed on a Perkin Elmer ELAN DRC II ICP-MS after minimal dilution using O2 as the reaction gas. Analysis of continuing calibration verification standards indicated that the DRC mode could be used for quantitative analysis of 129I in samples below the drinking water standard (0.0057 ng/ml or 1 pCi/L). The low analytical detection limit of 129I analysis in the DRC mode coupled with minimal sample dilution (1.02x) resulted in a final sample limit of quantification of 0.0051 ng/ml. Subsequent analysis of three groundwater samples containing 129I resulted in fully quantitative results in the DRC mode, and spike recovery analyses performed on all three samples confirmed that the groundwater matrix did not adversely impact the analysis of 129I in the DRC mode. This analytical approach has been proven to be a cost-effective, high-throughput technique for the direct, quantitative analysis of 129I in groundwater samples at concentrations below the current MCL.

  8. Biochemical and cellular effects of electrophiles present in ambient air samples

    NASA Astrophysics Data System (ADS)

    Iwamoto, Noriko; Nishiyama, Akira; Eiguren-Fernandez, Arantzazu; Hinds, William; Kumagai, Yoshito; Froines, John R.; Cho, Arthur K.; Shinyashiki, Masaru

    2010-04-01

    Ambient vapor-phase samples collected in Riverside, California had shown that both redox and electrophilic activity were present, with the vapor phase containing higher levels of electrophiles than the particle phase. In this study, the biochemical effects of the vapor-phase electrophiles were examined using the purified thiol proteins, glyceraldehyde-3-phosphate dehydrogenase (GAPDH), protein tyrosine phosphatase 1B (PTP1B) and KELCH-1 like ECH-associated protein 1 (Keap1). The results demonstrated that the thiol proteins were inactivated by the vapor-phase samples through covalent modifications. Next, two cellular responses, epidermal growth factor receptor (EGFR)/mitogen-activated protein (MAP) kinase and NF-E2-related factor 2 (Nrf2), to the ambient vapor-phase samples were assessed in A549 and RAW 264.7 cell lines, respectively. The vapor-phase samples, at non-oxidative concentrations, increased phosphorylation of EGFR, which is negatively regulated by PTP1B, and its downstream MAP kinase, extracellular signal-regulated kinase (ERK)1/2. Activation of Nrf2, which requires Keap1 alkylation, and expression of its downstream proteins were also observed. The electrophilic compounds present in ambient vapor-phase were shown to modify cellular proteins through covalent modification and to activate diverse cellular responses that can lead to inflammatory and adaptive responses.

  9. RESULTS OF ANALYSES OF THE MACROBATCH 4 TANK 49H CONFIRMATORY SAMPLE

    SciTech Connect

    Peters, T.; Fink, S.

    2012-01-31

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 49H in support of qualification of Salt (Macro)Batch 4 for the Integrated Salt Disposition Project (ISDP). This document reports the results of the analyses of the confirmatory sample of Tank 49H. All sample results either agree with expectations based on prior analyses or are considered trivial enough not to warrant concern. No issues with the projected Salt Batch 4 strategy are identified. This report describes the laboratory results of Salt (Macro)Batch 4 confirmatory sample. These results will be used by Tank Farm Engineering for their blend calculations. This work was specified by Technical Task Request (TTR) and by Task Technical and Quality Assurance Plan (TTQAP).

  10. Deinococcus aerolatus sp. nov. and Deinococcus aerophilus sp. nov., isolated from air samples.

    PubMed

    Yoo, Seung-Hee; Weon, Hang-Yeon; Kim, Soo-Jin; Kim, Yi-Seul; Kim, Byung-Yong; Kwon, Soon-Wo

    2010-05-01

    Two strains of pink-coloured bacteria, 5516T-9(T) and 5516T-11(T), were isolated from an air sample collected in Korea. The taxonomic status of these novel strains was investigated by means of a polyphasic approach. The novel strains were Gram-positive, aerobic, non-spore-forming and coccus-shaped bacteria. The DNA G+C contents of strains 5516T-9(T) and 5516T-11(T) were 61.0 and 59.3 mol%, respectively. The major isoprenoid quinone for both strains was MK-8. Strain 5516T-9(T) contained summed feature 3 (iso-C(15 : 0) 2-OH and/or C(16 : 1)omega7c), C(16 : 0) and iso-C(17 : 1)omega9c, and strain 5516T-11(T) contained summed feature 3, iso-C(17 : 1)omega9c, C(17 : 1)omega8c and C(15 : 1)omega6c as the major fatty acids (>10 %). The polar lipid patterns of both strains were similar, comprising one phospholipid and one aminophospholipid as the major components. Phylogenetic analyses using 16S rRNA gene sequences showed that both novel strains were affiliated to the genus Deinococcus. Strain 5516T-9(T) exhibited the highest sequence similarity with Deinococcus marmoris DSM 12784(T) (96.8 %) and strain 5516T-11(T) showed the highest sequence similarity with Deinococcus saxicola DSM 15974(T) (94.5 %). The sequence similarity between strains 5516T-9(T) and 5516T-11(T) was 94.7 %. On the basis of the data presented, it is evident that both strains represent separate novel species of the genus Deinococcus for which the names Deinococcus aerolatus sp. nov. (type strain 5516T-9(T)=KACC 12745(T)=JCM 15442(T)) and Deinococcus aerophilus sp. nov. (type strain 5516T-11(T)=KACC 12746(T)=JCM 15443(T)) are proposed.

  11. Massilia jejuensis sp. nov. and Naxibacter suwonensis sp. nov., isolated from air samples.

    PubMed

    Weon, Hang-Yeon; Yoo, Seung-Hee; Kim, Soo-Jin; Kim, Yi-Seul; Anandham, Rangasamy; Kwon, Soon-Wo

    2010-08-01

    Two Gram-negative, motile, rod-shaped bacteria (strains 5317J-18T and 5414S-25T) were isolated from air samples collected in the Jeju Island and Suwon region of Korea, respectively. Phylogenetically, strain 5317J-18T was grouped with the genus Massilia with Massilia brevitalea byr23-80T as the closest relative (98.8% sequence similarity). Strain 5414S-25T was affiliated with the genus Naxibacter with Naxibacter haematophilus CCUG 38318T as the closest relative (98.8% sequence similarity). The mean DNA-DNA relatedness values between strain 5317J-18T and M. brevitalea DSM 18925T and Massilia aurea DSM 18055T were 43 and 36%, respectively. The mean DNA-DNA hybridization values between strain 5414S-25T and N. haematophilus KACC 13771T, M. brevitalea DSM 18925T, Massilia timonae DSM 16850T, Naxibacter varians KACC 13770T, M. aurea DSM 18055T, Massilia lutea DSM 17473T and Massilia albidiflava DSM 17472T ranged from 33 to 42%. Both novel strains had ubiquinone Q-8 as the predominant isoprenoid quinone and summed feature 3 (comprising iso-C15:0 2-OH and/or C16:1 omega7c) and C16:0 as the major fatty acids. Both strains also showed similar polar lipid profiles with phosphatidylethanolamine, phosphatidylglycerol and diphosphatidylglycerol as the major polar lipids. The DNA G+C contents of strains 5317J-18T and 5414S-25T were 66.1 and 67.8%, respectively. On the basis of their phenotypic, chemotaxonomic and genotypic characteristics, the new strains represent novel species in the genera Massilia and Naxibacter. Strain 5317J-18T (=KACC 12634T=DSM 21309T) is proposed as the type strain of Massilia jejuensis sp. nov. and strain 5414S-25T (=KACC 12635T=DSM 21311T) is proposed as the type strain of Naxibacter suwonensis sp. nov.

  12. RESULTS FOR THE MAY 19, 2010 INADVERTENT TRANSFER TO THE SALTSTONE DISPOSAL FACILITY SLURRY: SAMPLE ANALYTICAL RESULTS

    SciTech Connect

    Reigel, M.; Cozzi, A.

    2010-08-17

    This report details the chemical analysis results for the characterization of the May 19, 2010 inadvertent transfer from the Saltstone Production Facility (SPF) to the Saltstone Disposal Facility (SDF). On May 19, 2010, the Saltstone Processing Facility (SPF) inadvertently transferred approximately 1800 gallons of untreated low-level salt solution from the salt feed tank (SFT) to Cell F of Vault 4. The transfer was identified and during safe configuration shutdown, approximately 70 gallons of SFT material was left in the Saltstone hopper. After the shutdown, the material in the hopper was undisturbed, while the SFT has received approximately 1400 gallons of drain water from the Vault 4 bleed system. The drain water path from Vault 4 to the SFT does not include the hopper (Figure 1); therefore it was determined that the material remaining in the hopper was the most representative sample of the salt solution transferred to the vault. To complete item No.5 of Reference 1, Savannah River National Laboratory (SRNL) was asked to analyze the liquid sample retrieved from the hopper for pH, and metals identified by the Resource Conservation and Recovery Act (RCRA). SRNL prepared a report to complete item No.5 and determine the hazardous nature of the transfer. Waste Solidification Engineering then instructed SRNL to provide a more detailed analysis of the slurried sample to assist in the determination of the portion of Tank 50 waste in the hopper sample.

  13. Comparison of lichen, conifer needles, passive air sampling devices, and snowpack as passive sampling media to measure semi-volatile organic compounds in remote atmospheres.

    PubMed

    Schrlau, Jill E; Geiser, Linda; Hageman, Kimberly J; Landers, Dixon H; Simonich, Staci Massey

    2011-12-15

    A wide range of semivolatile organic compounds (SOCs), including pesticides and polycyclic aromatic hydrocarbons (PAHs), were measured in lichen, conifer needles, snowpack and XAD-based passive air sampling devices (PASDs) collected from 19 different U.S. national parks in order to compare the magnitude and mechanism of SOC accumulation in the different passive sampling media. Lichen accumulated the highest SOC concentrations, in part because of its long (and unknown) exposure period, whereas PASDs accumulated the lowest concentrations. However, only the PASD SOC concentrations can be used to calculate an average atmospheric gas-phase SOC concentration because the sampling rates are known and the media is uniform. Only the lichen and snowpack SOC accumulation profiles were statistically significantly correlated (r = 0.552, p-value <0.0001) because they both accumulate SOCs present in the atmospheric particle-phase. This suggests that needles and PASDs represent a different composition of the atmosphere than lichen and snowpack and that the interpretation of atmospheric SOC composition is dependent on the type of passive sampling media used. All four passive sampling media preferentially accumulated SOCs with relatively low air-water partition coefficients, while snowpack accumulated SOCs with higher log K(OA) values compared to the other media. Lichen accumulated more SOCs with log K(OA) > 10 relative to needles and showed a greater accumulation of particle-phase PAHs.

  14. Early detection of foot-and-mouth disease virus from infected cattle using a dry filter air sampling system

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Foot-and-mouth disease (FMD) is a highly contagious livestock disease of high economic impact. Early detection of FMD virus (FMDV) is fundamental for rapid outbreak control. Air sampling collection has been demonstrated as a useful technique for detection of FMDV RNA in infected animals, related to ...

  15. Inter-laboratory comparison study on measuring semi-volatile organic chemicals in standards and air samples.

    PubMed

    Su, Yushan; Hung, Hayley

    2010-11-01

    Measurements of semi-volatile organic chemicals (SVOCs) were compared among 21 laboratories from 7 countries through the analysis of standards, a blind sample, an air extract, and an atmospheric dust sample. Measurement accuracy strongly depended on analytes, laboratories, and types of standards and samples. Intra-laboratory precision was generally good with relative standard deviations (RSDs) of triplicate injections <10% and with median differences of duplicate samples between 2.1 and 22%. Inter-laboratory variability, measured by RSDs of all measurements, was in the range of 2.8-58% in analyzing standards, and 6.9-190% in analyzing blind sample and air extract. Inter-laboratory precision was poorer when samples were subject to cleanup processes, or when SVOCs were quantified at low concentrations. In general, inter-laboratory differences up to a factor of 2 can be expected to analyze atmospheric SVOCs. When comparing air measurements from different laboratories, caution should be exercised if the data variability is less than the inter-laboratory differences.

  16. Results of initial analyses of the salt (macro) batch 9 tank 21H qualification samples

    SciTech Connect

    Peters, T. B.

    2015-10-01

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 9 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 9 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amount of solids, or unusual colors. Further results on the chemistry and other tests will be issued in the future.

  17. Results Of Initial Analyses Of The Salt (Macro) Batch 9 Tank 21H Qualification Samples

    SciTech Connect

    Peters, T.

    2015-10-08

    Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 9 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 9 composite sample indicates that the material does not display any unusual characteristics. Further results on the chemistry and other tests will be issued in the future.

  18. Waste tank vapor project: Vapor space characterization of waste tank 241-BY-104: Results from samples collected on June 24, 1994

    SciTech Connect

    Clauss, T.W.; Ligotke, M.W.; McVeety, B.D.; Pool, K.H.; Lucke, R.B.; Fruchter, J.S.; Goheen, S.C.

    1994-11-01

    This report describes results of the analyses of tank-headspace samples taken from Hanford waste Tank 241-BY-104 (referred to as Tank BY-104) on June 24, 1994. The Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze inorganic and organic samples collected from the tank headspace. The sample job was designated S4019 and was performed by WHC on June 24, 1994 using the vapor sampling system (VSS). The results of the analyses are expected to be used in the determination of safety and toxicological issues related to the tank-headspace gas as described in the WHC report entitled Data Quality Objectives for Generic In-Tank Health and Safety Vapor Issue Resolution, WHC-SD-WM-DQO-002, Rev. 0. Sampling devices, including 16 sorbent trains (for inorganic analyses), and 5 SUMMA{trademark} canisters (for organic analyses), were supplied to the WHC sampling staff on June 20, 1994. Samples were taken (by WHC) on June 24. The samples were returned from the field on June 27. The inorganic samples delivered to PNL on chain-of-custody (COC) 006893 included 16 sorbent trains as described in Tables 2.2, 2.3, and 2.4. Additional inorganic blank spikes were obtained from related sample jobs. SUMMA{trademark} samples delivered to PNL on COC 006896 included one ambient air sample, one ambient-air sample through the sampling system, and three tank-headspace SUMMA{trademark} canister samples. The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL laboratory record book 55408. Custody of the sorbent trains was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated ({le}10{degrees}C) temperature until the time of analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program.

  19. Transboundary Air Pollution over the Central Himalayas: Monitoring network and Preliminary Results

    NASA Astrophysics Data System (ADS)

    Zhang, Qianggong; Kang, Shichang

    2016-04-01

    The Himalayas, stretching over 3000 kms along west-east, separates South Asia continent and the Tibetan Plateau with its extreme high altitudes. The South Asia is being increasingly recognized to be among the hotspots of air pollution, posing multi-effects on regional climate and environment. Recent monitoring and projection have indicated an accelerated decrease of glacier and increasing glacier runoff in the Himalayas, and a remarkable phenomenon has been recognized in the Himalayas that long-range transport atmospheric pollutants (e.g., black carbon and dust) deposited on glacier surface can promote glacier melt, and in turns, may liberate historical contaminant legacy in glaciers into downward ecosystems. To understand the air pollution variation and how they can infiltrate the Himalayas and beyond, we started to operate a coordinated atmospheric pollution monitoring network composing 11 sites with 5 in Nepal and 6 in Tibet since April 2013. Atmospheric total suspended particles ( TSP < 100 μm) are collected for 24h at an interval of 3-6 days at all sites. Black carbon, typical persistent organic pollutants (PAHs) and heavy metals (particulate-bounded mercury) are measured to reveal their spatial and temporal distributions. Results revealed a consistent gradient decrease in almost all analyzed parameters along south-north gradient across the Himalayas, with a clear seasonal variation of higher values in pre-monsoon seasons. Analysis of geochemical signatures of carbonaceous aerosols indicated dominant sources from biomass burning and vehicle exhaust. PAHs concentrations and signatures from soils and aerosols indicated that low-ring PAHs can readily transport across the Himalayas. Integrated analysis of satellite images and air mass trajectories suggested that the transboundary air pollution over the Himalayas is episodic and is likely concentrated in pre-monsoon seasons. Our results emphasis the potential transport and impact of air pollution from South Asia

  20. 40 CFR Appendix I to Subpart T of... - Sample Graphical Summary of NTE Emission Results

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emission Results I Appendix I to Subpart T of Part 86 Protection of Environment ENVIRONMENTAL PROTECTION..., App. I Appendix I to Subpart T of Part 86—Sample Graphical Summary of NTE Emission Results The following figure shows an example of a graphical summary of NTE emission results: ER14JN05.002...

  1. 40 CFR Appendix I to Subpart T of... - Sample Graphical Summary of NTE Emission Results

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emission Results I Appendix I to Subpart T of Part 86 Protection of Environment ENVIRONMENTAL PROTECTION... Appendix I to Subpart T of Part 86—Sample Graphical Summary of NTE Emission Results The following figure shows an example of a graphical summary of NTE emission results: ER14JN05.002...

  2. A spatial multicriteria model for determining air pollution at sample locations.

    PubMed

    Réquia Júnior, Weeberb João; Roig, Henrique Llacer; Koutrakis, Petros

    2015-02-01

    Atmospheric pollution in urban centers has been one of the main causes of human illness related to the respiratory and circulatory system. Efficient monitoring of air quality is a source of information for environmental management and public health. This study investigates the spatial patterns of atmospheric pollution using a spatial multicriteria model that helps target locations for air pollution monitoring sites. The main objective was to identify high-priority areas for measuring human exposures to air pollutants as they relate to emission sources. The method proved to be viable and flexible in its application to various areas.

  3. Formation and growth of indoor air aerosol particles as a result of D-limonene oxidation

    NASA Astrophysics Data System (ADS)

    Vartiainen, E.; Kulmala, M.; Ruuskanen, T. M.; Taipale, R.; Rinne, J.; Vehkamäki, H.

    Oxidation of D-limonene, which is a common monoterpene, can lead to new aerosol particle formation in indoor environments. Thus, products containing D-limonene, such as citrus fruits, air refresheners, household cleaning agents, and waxes, can act as indoor air aerosol particle sources. We released D-limonene into the room air by peeling oranges and measured the concentration of aerosol particles of three different size ranges. In addition, we measured the concentration of D-limonene, the oxidant, and the concentration of ozone, the oxidizing gas. Based on the measurements we calculated the growth rate of the small aerosol particles, which were 3-10 nm in diameter, to be about 6300nmh-1, and the losses of the aerosol particles that were due to the coagulation and condensation processes. From these, we further approximated the concentration of the condensable vapour and its source rate and then calculated the formation rate of the small aerosol particles. For the final result, we calculated the nucleation rate and the maximum number of molecules in a critical cluster. The nucleation rate was in the order of 105cm-3s-1 and the number of molecules in a critical-sized cluster became 1.2. The results were in agreement with the activation theory.

  4. Detection of airborne bacteria in a duck production facility with two different personal air sampling devices for an exposure assessment.

    PubMed

    Martin, Elena; Dziurowitz, Nico; Jäckel, Udo; Schäfer, Jenny

    2015-01-01

    Prevalent airborne microorganisms are not well characterized in industrial animal production buildings with respect to their quantity or quality. To investigate the work-related microbial exposure, personal bioaerosol sampling during the whole working day is recommended. Therefore, bioaerosol sampling in a duck hatchery and a duck house with two personal air sampling devices, a filter-based PGP and a NIOSH particle size separator, was performed. Subsequent, quantitative and qualitative analyses were carried out with" culture independent methods. Total cell concentrations (TCC) determined via fluorescence microscopy showed no difference between the two devices. In average, 8 × 10(6) cells/m(3) were determined in the air of the duck hatchery and 5 × 10(7) cells/m(3) in the air of the duck house. A Generated Restriction Fragment Length Polymorphism (RFLP) pattern revealed deviant bacterial compositions comparing samples collected with both devices. Clone library analyses based on 16S rRNA gene sequence analysis from the hatchery's air showed 65% similarity between the two sampling devices. Detailed 16S rRNA gene sequence analyses showed the occurrence of bacterial species like Acinetobacter baumannii, Enterococcus faecalis, Escherichia sp., and Shigella sp.; and a group of Staphylococcus delphini, S. intermedius, and S. pseudintermedius that provided the evidence of potential exposure to risk group 2 bacteria at the hatchery workplace. Size fractionated sampling with the developed by the Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA) device revealed that pathogenic bacteria would deposit in the inhalable, the thorax, and possibly alveolar dust fraction according to EN481. TCC analysis showed the deposition of bacterial cells in the third stage (< 1μm) at the NIOSH device which implies that bacteria can reach deep into the lungs and contaminate the alveolus after inhalation. Nevertheless, both personal sampling devices

  5. Vapor-phase and particulate-associated pesticides and PCB concentrations in eastern North Dakota air samples

    SciTech Connect

    Hawthorne, S.B.; Miller, D.J.; Louie, P.K.K.

    1996-05-01

    Vapor-phase and suspended particulate (<50 {mu}m) samples were collected on polyurethane foam (PUF) and quartz fiber filters in rural North Dakota to determine the air concentrations of pesticides in an area where agriculture is a primary source of semivolatile pollutants. Samples were collected at two sites from 1992 to 1994 that were at least 0.4 km from the nearest farmed fields and known application of pesticides, and analyzed for 22 different organochlorine, triazine, and acid herbicide pesticides. Fourteen pesticides were found above the detection limits (typically <1 pg/m{sup 3}). Concentrations of polychlorinated biphenyl (PCB) congeners were much lower (<50 pg/m{sup 3} in all cases) than many of the pesticides. These results demonstrate that pesticides are among the most prevalent chlorinated semivolatile pollutants present in rural North Dakota, that significant transport of pesticides occurs both in the vapor-phase and on suspended particulate matter, and that blown soil may be a significant mechanism for introducing pesticides into surface and ground waters. 32 refs., 2 figs., 4 tabs.

  6. Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types.

    PubMed

    McAlary, Todd; Groenevelt, Hester; Disher, Stephen; Arnold, Jason; Seethapathy, Suresh; Sacco, Paolo; Crump, Derrick; Schumacher, Brian; Hayes, Heidi; Johnson, Paul; Górecki, Tadeusz

    2015-05-01

    This article describes laboratory testing of four passive diffusive samplers for assessing indoor air concentrations of volatile organic compounds (VOCs), including SKC Ultra II, Radiello®, Waterloo Membrane Sampler (WMS) and Automated Thermal Desorption (ATD) tubes with two different sorbents (Tenax TA and Carbopack B). The testing included 10 VOCs (including chlorinated ethenes, ethanes, and methanes, aromatic and aliphatic hydrocarbons), spanning a range of properties and including some compounds expected to pose challenges (naphthalene, methyl ethyl ketone). Tests were conducted at different temperatures (17 to 30 °C), relative humidities (30 to 90% RH), face velocities (0.014 to 0.41 m s(-1)), concentrations (1 to 100 parts per billion by volume [ppbv]) and sampling durations (1 to 7 days). The results show that all of the passive samplers provided data that met the success criteria (relative percent difference [RPD] ≤ 45% of active sample concentrations and coefficient of variation [COV] ≤ 30%) in the majority of cases, but some compounds were problematic for some samplers. The passive sampler uptake rates depend to varying degrees on the sampler, sorbent, target compounds and environmental conditions, so field calibration is advantageous for the highest levels of data quality.

  7. Sample Results From The Interim Salt Disposition Program Macrobatch 7 Tank 21H Qualification MST Solids Sample

    SciTech Connect

    Washington, A. L. II; Peters, T. B.

    2013-09-19

    Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Interim Salt Disposition Program (ISDP) Batch 7 processing. The Marcrobatch 7 material was received with visible fine particulate solids, atypical for these samples. The as received material was allowed to settle for a period greater than 24 hours. The supernatant was then decanted and utilized as our clarified feed material. As part of this qualification work, SRNL performed an Actinide Removal Process (ARP) test using the clarified feed material. From this test, the residual monosodium titanate (MST) was analyzed for radionuclide uptake after filtration from H-Tank Farm (HTF) feed salt solution. The results of these analyses are reported and are within historical precedent.

  8. EXPOSURE ANALYSIS FROM PERSONAL AND AMBIENT AIR SAMPLING: RESULTS OF THE 1998 BALTIMORE STUDY

    EPA Science Inventory

    An integrated epidemiological-exposure panel study was conducted during July-August 1998 which focused upon establishing relationships between potential human exposures to particulate matter (PM) and related co-pollutants with detectable health effects. The study design incorpo...

  9. Evaluation of a method to detect Mycobacterium bovis in air samples from infected Eurasian badgers (Meles meles) and their setts.

    PubMed

    Jones, R M; Ashford, R; Cork, J; Palmer, S; Wood, E; Spyvee, P; Parks, S; Bennett, A; Brewer, J; Delahay, R; Chambers, M; Sawyer, J

    2013-05-01

    Environmental air sampling was evaluated as a method to detect the presence of M. bovis in the vicinity of infected badgers and their setts. Airborne particles were collected on gelatine filters using a commercially available air sampling instrument and tested for the presence of M. bovis using bacteriological culture and real-time PCR. The sensitivity of bacteriological culture was broadly similar to that of real-time PCR when testing samples artificially spiked with M. bovis. Sampling was undertaken from directly under the muzzles of badgers which had been experimentally infected with M. bovis (37 samples), within enclosures housing the experimentally infected animals (50 samples), and in the vicinity of setts with resident infected wild badgers (52 samples). The methods employed did not detect M. bovis from either infected badgers or artificial or natural setts known to contain infected animals. However, samples taken at four of the six natural setts were positive for Mycobacterium gordonae.

  10. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - BAGHOUSE FILTRATION PRODUCTS - AIR PURATOR CORPORATION HUYGLAS 1405M FILTER SAMPLE

    EPA Science Inventory

    Baghouse filtration products (BFPs) were evaluated by the Air Pollution Control Technology (APCT) pilot of the Environmental Technology Verification (ETV) Program. The performance factor verified was the mean outlet particle concentration for the filter fabric as a function of th...

  11. Detection of Legionella spp. by a nested-PCR assay in air samples of a wastewater treatment plant and downwind distances in Isfahan

    PubMed Central

    Mirzaee, Seyyed Abbas; Nikaeen, Mahnaz; Hajizadeh, Yaghob; Nabavi, BiBi Fatemeh; Hassanzadeh, Akbar

    2015-01-01

    Background: Wastewater contains a variety of pathogens and bio -aerosols generated during the wastewater treatment process, which could be a potential health risk for exposed individuals. This study was carried out to detect Legionella spp. in the bio -aerosols generated from different processes of a wastewater treatment plant (WWTP) in Isfahan, Iran, and the downwind distances. Materials and Methods: A total of 54 air samples were collected and analyzed for the presence of Legionella spp. by a nested- polymerase chain reaction (PCR) assay. A liquid impingement biosampler was used to capture bio -aerosols. The weather conditions were also recorded. Results: Legionella were detected in 6% of the samples, including air samples above the aeration tank (1/9), belt filter press (1/9), and 250 m downwind (1/9). Conclusion: The result of this study revealed the presence of Legionella spp. in air samples of a WWTP and downwind distance, which consequently represent a potential health risk to the exposed individuals. PMID:25802817

  12. Determination of methyl bromide in air resulting from pre-plant fumigations of plowed fields

    SciTech Connect

    Woodrow, J.E.; Honaganahalli, P.; Seiber, J.N.

    1995-12-31

    A method for measuring residues of methyl bromide in air entails concentrating the fumigant on charcoal from an airstream at a flowrate of 100 ml/min, desorption of the trapped material with benzyl alcohol solvent in a sealed vial at 60-110{degrees}C for 10-15 min, and then sampling of the equilibrated vapor for gas chromatographic assay using electron-capture detection. The desorbed vapor is chromatographed on a 27 in x 0.32 mm (id) porous-layer open tubular column, on which methyl bromide has a retention time of about 6 min at 90{degrees}C and at a carrier gas flowrate of 3-3.5 ml/min. Using this method, standard curves were linear over at least three orders of magnitude and a practical limit of detection for field air was about 20 ng/m{sup 3} ({approximately}5 ppt). This method has been used in studies concerned with methyl bromide volatilization from fumigated fields and with ambient background levels.

  13. Nitrogen isotopes determination in natural gas: analytical method and first results on magmatic, hydrothermal and soil gas samples.

    PubMed

    Grassa, Fausto; Capasso, Giorgio; Oliveri, Ygor; Sollami, Aldo; Carreira, Paula; Rosario Carvalho, M; Marques, Jose M; Nunes, Joao C

    2010-06-01

    A continuous-flow GC/IRMS technique has been developed to analyse delta(15)N values for molecular nitrogen in gas samples. This method provides reliable results with accuracy better than 0.15 per thousand and reproducibility (1sigma) within+/-0.1 per thousand for volumes of N(2) between 1.35 (about 56 nmol) and 48.9 muL (about 2 mumol). The method was tested on magmatic and hydrothermal gases as well as on natural gas samples collected from various sites. Since the analysis of nitrogen isotope composition may be prone to atmospheric contamination mainly in samples with low N(2) concentration, we set the instrument to determine also N(2) and (36)Ar contents in a single run. In fact, based on the simultaneously determined N(2)/(36)Ar ratios and assuming that (36)Ar content in crustal and mantle-derived fluids is negligible with respect to (36)Ar concentration in the atmosphere, for each sample, the degree of atmospheric contamination can be accurately evaluated. Therefore, the measured delta(15)N values can be properly corrected for air contamination.

  14. Uranium speciation in moorland river water samples: a comparison of experimental results and computer model predictions.

    PubMed

    Unsworth, Emily R; Jones, Phil; Cook, Jennifer M; Hill, Steve J

    2005-06-01

    An on-line method has been developed for separating inorganic and organic bound uranium species present in river water samples. The method utilised a small chelating resin (Hyphan) column incorporated into the sample introduction manifold of an ICP-MS instrument. The method was evaluated for samples from rivers on Dartmoor (Devon, UK), an area of granite overlain with peat bogs. The results indicate that organic-uranium species form a major proportion (80%) of the total dissolved uranium present. Further work with synthetic water samples indicated that the level of dissolved organic carbon played a greater role in determining the level of organic-uranium species than did sample pH. Computer models for the water samples were constructed using the WHAM program (incorporating uranium data from the Nuclear Energy Agency Thermochemical Database project) in order to predict the levels of organic-uranium species that would form. By varying the proportion of humic and fulvic acids used in the humic component, predictions within 10% of the experimental results were obtained. The program did exhibit a low bias at higher pH values (7.5) and low organic carbon concentrations (0.5 microg ml(-1)), but under the natural conditions prevalent in the Dartmoor water samples, the model predictions were successful.

  15. Technique for determination of accurate heat capacities of volatile, powdered, or air-sensitive samples using relaxation calorimetry

    NASA Astrophysics Data System (ADS)

    Marriott, Robert A.; Stancescu, Maria; Kennedy, Catherine A.; White, Mary Anne

    2006-09-01

    We introduce a four-step technique for the accurate determination of the heat capacity of volatile or air-sensitive samples using relaxation calorimetry. The samples are encapsulated in a hermetically sealed differential scanning calorimetry pan, in which there is an internal layer of Apiezon N grease to assist thermal relaxation. Using the Quantum Design physical property measurement system to investigate benzoic acid and copper standards, we find that this method can lead to heat capacity determinations accurate to ±2% over the temperature range of 1-300K, even for very small samples (e.g., <10mg and contributing ca. 20% to the total heat capacity).

  16. Modelling relationships between lichen bioindicators, air quality and climate on a national scale: results from the UK OPAL air survey.

    PubMed

    Seed, Lindsay; Wolseley, Pat; Gosling, Laura; Davies, Linda; Power, Sally A

    2013-11-01

    Air pollution has many negative effects on the natural environment, from changes in plant growth patterns to loss of ecosystem function. This study uses citizen science to investigate national-scale patterns in the distribution and abundance of selected lichen species on tree trunks and branches, and to relate these to air pollution and climate. Volunteers collected data for nine lichen indicators on 19,334 deciduous trees. Submitted data provided information on species-level patterns, and were used to derive composite lichen indices. Multiple linear regression and ANCOVA were used to model the relationships between lichen response variables on Quercus spp. and pollution, climate and location. The study demonstrated significant relationships between patterns in indicator lichens and levels of N- and S-containing pollutants on trunks and twigs. The derived lichen indices show great potential as a tool to provide information on local, site-specific levels of air quality. PMID:23992684

  17. 45-Day safety screen results for Tank 241-C-101, auger sample 95-AUG-019

    SciTech Connect

    Sasaki, L.M.

    1995-05-11

    One auger sample from Tank 241-C-101 was received by the 222-S Laboratory and underwent safety screening analyses--differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha analysis--in accordance with the tank characterization plan. Analytical results for the TGA on the crust sample (the uppermost portion of the auger sample) (sample number S95T000823) were less than the safety screening notification limit of 17 weight percent water. Verbal and written notifications were made on May 3, 1995. No exotherms were observed in the DSC analyses and the total alpha results were well below the safety screening notification limit. This report includes the primary safety screening results obtained from the analyses and copies of all DSC and TGA raw data scans as requested per the TCP. Although not included in this report, a photograph of the extruded sample was taken and is available. This report also includes bulk density measurements required by Characterization Plant Engineering. Additional analyses (pH, total organic carbon, and total inorganic carbon) are being performed on the drainable liquid at the request of Characterization Process Control; these analyses will be reported at a later date in a final report for this auger sample. Tank C-101 is not part of any of the four Watch Lists.

  18. 40 CFR Appendix I to Subpart T - Sample Graphical Summary of NTE Emission Results

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emission Results I Appendix I to Subpart T Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... (CONTINUED) Manufacturer-Run In-Use Testing Program for Heavy-Duty Diesel Engines Pt. 86, Subpt. T, App. I Appendix I to Subpart T—Sample Graphical Summary of NTE Emission Results The following figure shows...

  19. Utilizing Internal Standard Responses to Assess Risk on Reporting Bioanalytical Results from Hemolyzed Samples.

    PubMed

    Fung, Eliza N; Aubry, Anne-Françoise; Allentoff, Alban; Ji, Qin C

    2015-09-01

    Bioanalytical analysis of toxicokinetic and pharmacokinetic samples is an integral part of small molecule drugs development and liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been the technique of choice. One important consideration is the matrix effect, in which ionization of the analytes of interest is affected by the presence of co-eluting interfering components present in the sample matrix. Hemolysis, which results in additional endogenous components being released from the lysed red blood cells, may cause additional matrix interferences. The effects of the degree of hemolysis on the accuracy and precision of the method and the reported sample concentrations from hemolyzed study samples have drawn increasing attention in recent years, especially in cases where the sample concentrations are critical for pharmacokinetic calculation. Currently, there is no established procedure to objectively assess the risk of reporting potentially inaccurate bioanalytical results from hemolyzed study samples. In this work, we evaluated the effect of different degrees of hemolysis on the internal standard peak area, accuracy, and precision of the analyses of BMS-906024 and its metabolite, BMS-911557, in human plasma by LC-MS/MS. In addition, we proposed the strategy of using the peak area of the stable isotope-labeled internal standard (SIL-IS) from the LC-MS/MS measurement as the surrogate marker for risk assessment. Samples with peak areas outside of the pre-defined acceptance criteria, e.g., less than 50% or more than 150% of the average IS response in study samples, plasma standards, and QC samples when SIL-IS is used, are flagged out for further investigation. PMID:25975617

  20. Preserving ground water samples with hydrochloric acid does not result in the formation of chloroform

    USGS Publications Warehouse

    Squillace, Paul J.; Pankow, James F.; Barbash, Jack E.; Price, Curtis V.; Zogorski, John S.

    1999-01-01

    Water samples collected for the determination of volatile organic compounds (VOCs) are often preserved with hydrochloric acid (HCl) to inhibit the biotransformation of the analytes of interest until the chemical analyses can he performed. However, it is theoretically possible that residual free chlorine in the HCl can react with dissolved organic carbon (DOC) to form chloroform via the haloform reaction. Analyses of 1501 ground water samples preserved with HCl from the U.S. Geological Survey's National Water-Quality Assessment Program indicate that chloroform was the most commonly detected VOC among 60 VOCs monitored. The DOC concentrations were not significantly larger in samples with detectable chloroform than in those with no delectable chloroform, nor was there any correlation between the concentrations of chloroform and DOC. Furthermore, chloroform was detected more frequently in shallow ground water in urban areas (28.5% of the wells sampled) than in agricultural areas (1.6% of the wells sampled), which indicates that its detection was more related to urban land-use activities than to sample acidification. These data provide strong evidence that acidification with HCl does not lead to the production of significant amounts of chloroform in ground water samples. To verify these results, an acidification study was designed to measure the concentrations of all trihalomethanes (THMs) that can form as a result of HCl preservation in ground water samples and to determine if ascorbic acid (C6H8O6) could inhibit this reaction if it did occur. This study showed that no THMs were formed as a result of HCl acidification, and that ascorbic acid had no discernible effect on the concentrations of THMs measured.

  1. Comparison of passive diffusion bag samplers and submersible pump sampling methods for monitoring volatile organic compounds in ground water at Area 6, Naval Air Station, Whidbey Island, Washington

    USGS Publications Warehouse

    Huffman, Raegan L.

    2002-01-01

    Ground-water samples were collected in April 1999 at Naval Air Station Whidbey Island, Washington, with passive diffusion samplers and a submersible pump to compare concentrations of volatile organic compounds (VOCs) in water samples collected using the two sampling methods. Single diffusion samplers were installed in wells with 10-foot screened intervals, and multiple diffusion samplers were installed in wells with 20- to 40-foot screened intervals. The diffusion samplers were recovered after 20 days and the wells were then sampled using a submersible pump. VOC concentrations in the 10-foot screened wells in water samples collected with diffusion samplers closely matched concentrations in samples collected with the submersible pump. Analysis of VOC concentrations in samples collected from the 20- to 40-foot screened wells with multiple diffusion samplers indicated vertical concentration variation within the screened interval, whereas the analysis of VOC concentrations in samples collected with the submersible pump indicated mixing during pumping. The results obtained using the two sampling methods indicate that the samples collected with the diffusion samplers were comparable with and can be considerably less expensive than samples collected using a submersible pump.

  2. Effect of poppy seed consummation on the positive results of opiates screening in biological samples.

    PubMed

    Jankovicová, Katarína; Ulbrich, Pavol; Fuknová, Mária

    2009-04-01

    Poppy seed is a popular substance of many traditional Slovak cakes. We can eat quite great amount of it, sometimes more than 50 g. Existing problem in interpreting the results of opiate urine analysis in case of drug abuse arises from the natural occurrence of opiate alkaloids in poppy seed. Interpretation of morphine presence in urine sample is in some cases a problem because morphine present in the urine sample may come from different "sources". The presence of additional, respectively, other opiate in urine sample is significant help when interpreting the presence of morphine. We used poppy seed bought in supermarket for our experiment. Presence of morphine and codeine was determined in poppy seed extracts, whereas the concentration of majority opiate-morphine was 0.9 mg/100 g (9 ppm). This poppy seed was used for two series of experiment-poppy seed consummation, where four persons consumed 100g of poppy seed in the first series and 50 g in the second series. Urine samples were taken in regular 1h intervals where first urine sample was given for testing 3 h after consummation. Concentrations of total opiates were determined in each urine sample by screening examination. Morphine concentrations were determined in selected urine samples using GC/MS with internal standard.

  3. Comparison of air-coupled GPR data analysis results determined by multiple analysts

    NASA Astrophysics Data System (ADS)

    Martino, Nicole; Maser, Ken

    2016-04-01

    Current bridge deck condition assessments using ground penetrating radar (GPR) requires a trained analyst to manually interpret substructure layering information from B-scan images in order to proceed with an intended analysis (pavement thickness, concrete cover, effects of rebar corrosion, etc.) For example, a recently developed method to rapidly and accurately analyze air-coupled GPR data based on the effects of rebar corrosion, requires that a user "picks" a layer of rebar reflections in each B-scan image collected along the length of the deck. These "picks" have information like signal amplitude and two way travel time. When a deck is new, or has little rebar corrosion, the resulting layer of rebar reflections is readily evident and there is little room for subjectivity. However, when a deck is severely deteriorated, the rebar layer may be difficult to identify, and different analysts may make different interpretations of the appropriate layer to analyze. One highly corroded bridge deck, was assessed with a number of nondestructive evaluation techniques including 2GHz air-coupled GPR. Two trained analysts separately selected the rebar layer in each B-scan image, choosing as much information as possible, even in areas of significant deterioration. The post processing of the selected data points was then completed and the results from each analyst were contour plotted to observe any discrepancies. The paper describes the differences between ground coupled and air-coupled GPR systems, the data collection and analysis methods used by two different analysts for one case study, and the results of the two different analyses.

  4. Ancillary human health benefits of improved air quality resulting from climate change mitigation

    PubMed Central

    Bell, Michelle L; Davis, Devra L; Cifuentes, Luis A; Krupnick, Alan J; Morgenstern, Richard D; Thurston, George D

    2008-01-01

    Background Greenhouse gas (GHG) mitigation policies can provide ancillary benefits in terms of short-term improvements in air quality and associated health benefits. Several studies have analyzed the ancillary impacts of GHG policies for a variety of locations, pollutants, and policies. In this paper we review the existing evidence on ancillary health benefits relating to air pollution from various GHG strategies and provide a framework for such analysis. Methods We evaluate techniques used in different stages of such research for estimation of: (1) changes in air pollutant concentrations; (2) avoided adverse health endpoints; and (3) economic valuation of health consequences. The limitations and merits of various methods are examined. Finally, we conclude with recommendations for ancillary benefits analysis and related research gaps in the relevant disciplines. Results We found that to date most assessments have focused their analysis more heavily on one aspect of the framework (e.g., economic analysis). While a wide range of methods was applied to various policies and regions, results from multiple studies provide strong evidence that the short-term public health and economic benefits of ancillary benefits related to GHG mitigation strategies are substantial. Further, results of these analyses are likely to be underestimates because there are a number of important unquantified health and economic endpoints. Conclusion Remaining challenges include integrating the understanding of the relative toxicity of particulate matter by components or sources, developing better estimates of public health and environmental impacts on selected sub-populations, and devising new methods for evaluating heretofore unquantified and non-monetized benefits. PMID:18671873

  5. Thermal desorption-gas chromatography-mass spectrometry method to determine phthalate and organophosphate esters from air samples.

    PubMed

    Aragón, M; Borrull, F; Marcé, R M

    2013-08-16

    A method based on thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) has been developed to determine four organophosphate esters, seven phthalate esters, and bis(2-ethylhexyl) adipate in the gas phase from harbour and urban air samples. The method involves the sampling of 1.5L of air in a Tenax TA sorbent tube followed by thermal desorption (using a Tenax TA cryogenic trap) coupled to gas chromatography-mass spectrometry. The repeatability of the method expressed as %RSD (n=3) is less than 15% and the MQLs are between 0.007μgm(-3) (DMP, TBP, BBP, TPP and DnOP) and 6.7μgm(-3) (DEHP). The method was successfully applied in two areas (urban and harbour) testing two and three points in each one, respectively. Some of these compounds were found in both urban and harbour samples. Di-(2-ethylhexyl)phthalate was the most abundant compound found in both areas at concentration levels between 6.7μgm(-3) and 136.4μgm(-3). This study demonstrates that thermal desorption is an efficient method for the determination of these semi-volatile compounds in the gas phase fraction of air samples.

  6. Detection of Campylobacter Bacteria in Air Samples for Continuous Real-Time Monitoring of Campylobacter Colonization in Broiler Flocks▿

    PubMed Central

    Olsen, Katja N.; Lund, Marianne; Skov, Julia; Christensen, Laurids S.; Hoorfar, Jeffrey

    2009-01-01

    Improved monitoring tools are important for the control of Campylobacter bacteria in broiler production. In this study, we compare the sensitivities of detection of Campylobacter by PCR with feces, dust, and air samples during the lifetimes of broilers in two poultry houses and conclude that the sensitivity of detection of Campylobacter in air is comparable to that in other sample materials. Profiling of airborne particles in six poultry houses revealed that the aerodynamic conditions were dependent on the age of the chickens and very comparable among different poultry houses, with low proportions of particles in the 0.5- to 2-μm-diameter range and high proportions in the 2- to 5-μm-diameter range. Campylobacter could also be detected by PCR in air samples collected at the hanging stage during the slaughter process but not at the other stages tested at the slaughterhouse. The exploitation of airborne dust in poultry houses as a sample material for the detection of Campylobacter and other pathogens provides an intriguing possibility, in conjunction with new detection technologies, for allowing continuous or semicontinuous monitoring of colonization status. PMID:19201953

  7. Detection of Campylobacter bacteria in air samples for continuous real-time monitoring of Campylobacter colonization in broiler flocks.

    PubMed

    Olsen, Katja N; Lund, Marianne; Skov, Julia; Christensen, Laurids S; Hoorfar, Jeffrey

    2009-04-01

    Improved monitoring tools are important for the control of Campylobacter bacteria in broiler production. In this study, we compare the sensitivities of detection of Campylobacter by PCR with feces, dust, and air samples during the lifetimes of broilers in two poultry houses and conclude that the sensitivity of detection of Campylobacter in air is comparable to that in other sample materials. Profiling of airborne particles in six poultry houses revealed that the aerodynamic conditions were dependent on the age of the chickens and very comparable among different poultry houses, with low proportions of particles in the 0.5- to 2-microm-diameter range and high proportions in the 2- to 5-microm-diameter range. Campylobacter could also be detected by PCR in air samples collected at the hanging stage during the slaughter process but not at the other stages tested at the slaughterhouse. The exploitation of airborne dust in poultry houses as a sample material for the detection of Campylobacter and other pathogens provides an intriguing possibility, in conjunction with new detection technologies, for allowing continuous or semicontinuous monitoring of colonization status.

  8. ELECTROCHEMICAL CORROSION TEST RESULTS FOR TANK 241-SY-102 SUPERNATE GRAB SAMPLES

    SciTech Connect

    DUNCAN JB

    2007-04-09

    This report describes the electrochemical corrosion scans and conditions for testing of SY-102 supernatant samples taken December 2004. The testing was performed because the tank was under a Justification for Continued Operation allowing the supernatant composition to be outside the chemistry limits of Administrative Control 5.16, 'Corrosion Mitigation program'. A new electrochemical working electrode of A516 Grade 60 carbon steel was used for each scan; all scans were measured against a saturated calomel electrode, with carbon counter electrodes, and all scans were carried out at 50 C. The samples were scanned twice, once as received and once sparged with argon to deoxygenate the sample. For those scans conducted after argon purging, the corrosion rates ranged from 0.012 to 0.019 mpy. A test for stress corrosion cracking was carried out on one sample (2SY-04-07) with negative results.

  9. Challenges associated with the sampling and analysis of organosulfur compounds in air using real-time PTR-ToF-MS and offline GC-FID

    NASA Astrophysics Data System (ADS)

    Perraud, Véronique; Meinardi, Simone; Blake, Donald R.; Finlayson-Pitts, Barbara J.

    2016-03-01

    Organosulfur compounds (OSCs) are naturally emitted via various processes involving phytoplankton and algae in marine regions, from animal metabolism, and from biomass decomposition inland. These compounds are malodorant and reactive. Their oxidation to methanesulfonic and sulfuric acids leads to the formation and growth of atmospheric particles, which are known to influence clouds and climate, atmospheric chemical processes. In addition, particles in air have been linked to negative impacts on visibility and human health. Accurate measurements of the OSC precursors are thus essential to reduce uncertainties in their sources and contributions to particle formation in air. Two different approaches, proton-transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) and canister sampling coupled to gas chromatography with flame ionization detector (GC-FID), are compared for both laboratory standards (dimethyl sulfide, DMS; dimethyl disulfide, DMDS; dimethyl trisulfide, DMTS; and methanethiol, MTO) and for a complex sample. Results show that both techniques produce accurate quantification of DMS. While PTR-ToF-MS provides real-time measurements of all four OSCs individually, significant fragmentation of DMDS and DMTS occurs, which can complicate their identification in complex mixtures. Canister sampling coupled with GC-FID provides excellent sensitivity for DMS, DMDS, and DMTS. However, MTO was observed to react on metal surfaces to produce DMDS and, in the presence of hydrogen sulfide, even DMTS. Avoiding metal in sampling systems seems to be necessary for measuring all but dimethyl sulfide in air.

  10. Aerothermal test results from the first flight of the Pegasus air-launched space booster

    NASA Technical Reports Server (NTRS)

    Noffz, Gregory K.; Curry, Robert E.; Haering, Edward A., Jr.; Kolodziej, Paul

    1991-01-01

    A survey of temperature measurements at speeds through Mach 8.0 on the first flight of the Pegasus air-launched booster system is discussed. In addition, heating rates were derived from the temperature data obtained on the fuselage in the vicinity of the wing shock interaction. Sensors were distributed on the wing surfaces, leading edge, and on the wing-body fairing or fillet. Side-by-side evaluations were obtained for a variety of sensor installations. Details of the trajectory reconstruction through first-stage separation are provided. Given here are indepth descriptions of the sensor installations, temperature measurements, and derived heating rates along with interpretations of the results.

  11. Detection of Bacillus anthracis DNA in complex soil and air samples using next-generation sequencing.

    PubMed

    Be, Nicholas A; Thissen, James B; Gardner, Shea N; McLoughlin, Kevin S; Fofanov, Viacheslav Y; Koshinsky, Heather; Ellingson, Sally R; Brettin, Thomas S; Jackson, Paul J; Jaing, Crystal J

    2013-01-01

    Bacillus anthracis is the potentially lethal etiologic agent of anthrax disease, and is a significant concern in the realm of biodefense. One of the cornerstones of an effective biodefense strategy is the ability to detect infectious agents with a high degree of sensitivity and specificity in the context of a complex sample background. The nature of the B. anthracis genome, however, renders specific detection difficult, due to close homology with B. cereus and B. thuringiensis. We therefore elected to determine the efficacy of next-generation sequencing analysis and microarrays for detection of B. anthracis in an environmental background. We applied next-generation sequencing to titrated genome copy numbers of B. anthracis in the presence of background nucleic acid extracted from aerosol and soil samples. We found next-generation sequencing to be capable of detecting as few as 10 genomic equivalents of B. anthracis DNA per nanogram of background nucleic acid. Detection was accomplished by mapping reads to either a defined subset of reference genomes or to the full GenBank database. Moreover, sequence data obtained from B. anthracis could be reliably distinguished from sequence data mapping to either B. cereus or B. thuringiensis. We also demonstrated the efficacy of a microbial census microarray in detecting B. anthracis in the same samples, representing a cost-effective and high-throughput approach, complementary to next-generation sequencing. Our results, in combination with the capacity of sequencing for providing insights into the genomic characteristics of complex and novel organisms, suggest that these platforms should be considered important components of a biosurveillance strategy.

  12. Water- and Air-Quality Monitoring of the Sweetwater Reservoir Watershed, San Diego County, California-Phase One Results, Continued, 1999-2001

    USGS Publications Warehouse

    Mendez, Gregory O.; Foreman, William T.; Sidhu, Jagdeep S.; Majewski, Michael S.

    2007-01-01

    In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to assess the overall health of the Sweetwater watershed with respect to chemical contamination. The study included regular sampling of air and water at Sweetwater Reservoir for chemical contaminants, including volatile organic compounds, polycyclic aromatic hydrocarbons, pesticides, and major and trace elements. Background water samples were collected at Loveland Reservoir for volatile organic compounds and pesticides. The purpose of this study was to monitor changes in contaminant composition and concentration in the air and water resulting from the construction and operation of State Route 125 near Sweetwater Reservoir. To accomplish this, the study was divided into two phases. Phase One sampling was designed to establish baseline conditions for target compounds in terms of detection frequency and concentration in air and water. Phase Two sampling is planned to continue at the established monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment project may have on the water quality in the reservoir. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as low-use pesticides, trace metals, and wastewater compounds. This report describes the study design, and the sampling and analytical methods, and presents the results for the second and third years of the study (October 1999 to September 2001). Data collected during the first year of sampling (October 1998 to September 1999) were published in 2002.

  13. Comparison of environmental chemical results for split samples analyzed in different laboratories.

    PubMed

    Grant, C L; Jenkins, T F; Mudambi, A R

    1997-01-01

    Data comparisons were made for split or co-located samples analyzed in contract laboratories and quality assurance (QA) laboratories during environmental studies directed by the U.S. Army Corps of Engineers. Archived results were analyzed statistically as concentration ratios (contract laboratory/QA laboratory). Concentration ratios were found to be lognormally distributed, and this was the model used for comparisons. For metals in soils and volatile organic compounds (VOCs) in groundwater, 10.2% of metal ratios in soils and 5.6% of VOC ratios in groundwater exceeded limits of 0.40-2.50. Considering that both methods are multianalyte, we find that only 4.0% of the metal samples and 2.0% of the VOC samples had more than one outlier ratio per sample. More recent data produced very similar results. For VOCs, total petroleum hydrocarbons (TPHs), and explosives in soils, limits of 0.25-4.00 are suggested with the understanding that large improvements are badly needed. Even with these wide limits, approximately 42% of VOCs, 14% of TPHs, and 11% of explosives contract laboratory/QA laboratory ratios were outside these limits. Here, too, the most recent data yielded very comparable results. Sampling and preparation procedures for VOCs in soils requires immediate attention, but all methods can and should be capable of producing improved agreement between laboratories.

  14. Effects of air pollution resulting from wire reclamation incineration on pulmonary function in children

    SciTech Connect

    Hsiue, T.R.; Lee, S.S.; Chen, H.I. )

    1991-09-01

    This study evaluated the effect of long-term air pollution resulting from wire reclamation incineration on pulmonary function in children. General physical examination and the determination of spirometric parameters, including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and forced mid-expiratory flow (FEF25-75%) were conducted in 400 primary school children between ages 9 and 11 years who reside in one control and three polluted areas. A survey using ATS-DLD-78-C questionnaire indicated that there were no significant differences in their demographic characteristics among children in the four areas under study. Those who had nonrespiratory diseases that might affect pulmonary function and those who failed to perform spirometric measurements were excluded from the study; therefore, 382 children were included in data analysis. The results revealed that (1) the mean values of FVC and FEV1 (expressed as percentage of predicted values calculated from Polgar's equations) in the polluted areas were significantly lower than the nonpolluted area (p less than 0.05), and (2) the incidence of pulmonary function abnormality in the polluted areas was greater than that of the nonpolluted area (p less than 0.05). The results indicated that air pollution produced by wire reclamation incineration can impair children's pulmonary function.

  15. [Introduction of noninvasive prenatal testing for fetal trisomies: preliminary results and consequences on invasive samplings].

    PubMed

    Van Wymersch, D; Gilson, G

    2015-01-01

    Noninvasive prenatal testing (NIPT) has marked a revolution in aneuploidy screening because it allows a simple maternal blood test to detect trisomy 21, 18 and 13 in a foetus with a very high level of accuracy. After one year of NIPT utilisation with 683 samples, we analyzed retrospectively the performance of the test for 2014 : 3 positive samples (2 trisomies 21 and 1 trisomy 18) were correctly detected (100% sensitivity) and no foetal aneuploidy was missed for the pregnancies having already resulted in delivery by decembre 2014 (280 true negatif, 100% specificity). However, the additionnally available analysis of the sex chromosomes resulted in 2 erronous results: 1 uncorrect sex determination (1 male resulting in a female phenotype at birth) and 1 result suggesting a Turner syndrome was not confirmed by amniocentesis. The failure rate leading to a resampling was at 1.46% (10/683). The test used was the NIFTY of the BGI laboratory in Hong-Kong. By comparison to the year 2013, the utilisation of NIPT lead to a significant diminution of invasive samples performed by amniocentesis or choriocentesis 144 vs. 239 (- 63%). We confirmed that NIPT is a high-performance tool for the screening of the main foetal aneuploidies and report that during its first year of utilisation, 63% of invasive samples collected could be avoided. The test is expensive, not reimboursed by Luxembourg social security and therefore prohibitive for a number of women and their families. PMID:26946853

  16. A sample-to-result system for blood coagulation tests on a microfluidic disk analyzer.

    PubMed

    Lin, Chia-Hui; Liu, Cheng-Yuan; Shih, Chih-Hsin; Lu, Chien-Hsing

    2014-09-01

    In this report, we describe in detail a microfluidic analyzer, which is able to conduct blood coagulation tests using whole blood samples. Sample preparation steps, such as whole blood aliquoting and metering, plasma separation, decanting, and mixing with reagents were performed in sequence through microfluidic functions integrated on a disk. Both prothrombin time (PT) and activated partial thromboplastin time (aPTT) were carried out on the same platform and the test results can be reported in 5 min. Fifty clinical samples were tested for both PT and aPTT utilizing the microfluidic disk analyzer and the instrument used in hospitals. The test results showed good correlation and agreement between the two instruments.

  17. A sample-to-result system for blood coagulation tests on a microfluidic disk analyzer

    PubMed Central

    Lin, Chia-Hui; Liu, Cheng-Yuan; Shih, Chih-Hsin; Lu, Chien-Hsing

    2014-01-01

    In this report, we describe in detail a microfluidic analyzer, which is able to conduct blood coagulation tests using whole blood samples. Sample preparation steps, such as whole blood aliquoting and metering, plasma separation, decanting, and mixing with reagents were performed in sequence through microfluidic functions integrated on a disk. Both prothrombin time (PT) and activated partial thromboplastin time (aPTT) were carried out on the same platform and the test results can be reported in 5 min. Fifty clinical samples were tested for both PT and aPTT utilizing the microfluidic disk analyzer and the instrument used in hospitals. The test results showed good correlation and agreement between the two instruments. PMID:25332733

  18. MultiQC: summarize analysis results for multiple tools and samples in a single report

    PubMed Central

    Ewels, Philip; Magnusson, Måns; Lundin, Sverker; Käller, Max

    2016-01-01

    Motivation: Fast and accurate quality control is essential for studies involving next-generation sequencing data. Whilst numerous tools exist to quantify QC metrics, there is no common approach to flexibly integrate these across tools and large sample sets. Assessing analysis results across an entire project can be time consuming and error prone; batch effects and outlier samples can easily be missed in the early stages of analysis. Results: We present MultiQC, a tool to create a single report visualising output from multiple tools across many samples, enabling global trends and biases to be quickly identified. MultiQC can plot data from many common bioinformatics tools and is built to allow easy extension and customization. Availability and implementation: MultiQC is available with an GNU GPLv3 license on GitHub, the Python Package Index and Bioconda. Documentation and example reports are available at http://multiqc.info Contact: phil.ewels@scilifelab.se PMID:27312411

  19. Field Results from Application of the Outdoor-Air/Economizer Diagnostician for Commissioning and O&M

    SciTech Connect

    Pratt, Robert G.; Katipamula, Srinivas; Brambley, Michael R.; Blanc, Steven L.

    2000-05-31

    This paper presents results of field testing an automated diagnostician for outdoor-air-supply and economizer systems that can be used for commissioning purposes. The fundamental capabilities of the tool are described and key results of its application on six air handlers in a large hotel building are discussed. Ancillary issues pertinent to the development and application of such tools are also presented.

  20. Antibiotic residue monitoring results for pork, chicken, and beef samples in Vietnam in 2012-2013.

    PubMed

    Yamaguchi, Takahiro; Okihashi, Masahiro; Harada, Kazuo; Konishi, Yoshimasa; Uchida, Kotaro; Do, Mai Hoang Ngoc; Bui, Huong Dang Thien; Nguyen, Thinh Duc; Nguyen, Phuc Do; Chau, Vien Van; Dao, Khanh Thi Van; Nguyen, Hue Thi Ngoc; Kajimura, Keiji; Kumeda, Yuko; Bui, Chien Trong; Vien, Mai Quang; Le, Ninh Hoang; Hirata, Kazumasa; Yamamoto, Yoshimasa

    2015-06-01

    A monitoring plan of residual antibiotics in food of animal origin was conducted in Vietnam from 2012 to 2013. Meat samples were collected from slaughterhouses and retail stores in Ho Chi Minh City and Nha Trang. A total of 28 antibiotics were analyzed using a LC-MS/MS screening method. Sulfonamides, fluoroquinolones, and tilmicosin were detected in some of the samples. Sulfaclozine and fluoroquinolones were mainly detected in chicken samples, and sulfamethazine was mainly detected in pork samples. High levels of sulfonamide residues, ranging between 2500 and 2700 μg/kg sulfaclozine and between 1300 and 3600 μg/kg sulfamethazine, were present in two chicken and three pork samples, respectively. Tilmicosin was detected at ranges of 150-450 μg/kg in 10 chicken samples. Positive percentages were 17.3, 8.8, and 7.4% for chicken, pork, and beef, respectively, for an average of 11.9%. The results suggest an appropriate withdrawal period after drug administration had not been observed in some livestock. PMID:25601049

  1. 2015 Long-Term Hydrologic Monitoring Program Sampling and Analysis Results at Rio Blanco, Colorado

    SciTech Connect

    Findlay, Rick; Kautsky, Mark

    2015-12-01

    The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rio Blanco, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 20–21, 2015. This report documents the analytical results of the Rio Blanco annual monitoring event, the trip report, and the data validation package. The groundwater and surface water monitoring samples were shipped to the GEL Group Inc. laboratories for conventional analysis of tritium and analysis of gamma-emitting radionuclides by high-resolution gamma spectrometry. A subset of water samples collected from wells near the Rio Blanco site was also sent to GEL Group Inc. for enriched tritium analysis. All requested analyses were successfully completed. Samples were collected from a total of four onsite wells, including two that are privately owned. Samples were also collected from two additional private wells at nearby locations and from nine surface water locations. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and they were analyzed for tritium using the conventional method with a detection limit on the order of 400 picocuries per liter (pCi/L). Four locations (one well and three surface locations) were analyzed using the enriched tritium method, which has a detection limit on the order of 3 pCi/L. The enriched locations included the well at the Brennan Windmill and surface locations at CER-1, CER-4, and Fawn Creek 500 feet upstream.

  2. Passive air sampling of organochlorine pesticides in a northeastern state of India, Manipur.

    PubMed

    Devi, Ningombam Linthoingambi; Qi, Shihua; Chakraborty, Paromita; Zhang, Gan; Yadav, Ishwar Chandra

    2011-01-01

    Thirty-six polyurethane foam disk passive air samplers (PUF-PAS) were deployed over a year during January to December, 2009 at three locations, i.e., Imphal (urban site), Thoubal (rural site) and Waithou (alpine site) of Manipur, to assess the seasonal local atmospheric emission of selected organochlorine pesticides (OCPs). The average concentration of HCHs monitored at mountain site during hot season (Mar, Apr, and May) and rainy seasons (Jun, Jul, Aug, and Sep) were 403 and 349 pg/m3, respectively. DDTs had a high concentration with 384 pg/m3 at rural site and 379 pg/m3 at urban site during hot seasons. Endosulfans and chlordane were found high in concentration during hot seasons (260 pg/m3) and low during retreating monsoon seasons (44 pg/m3) at rural site. Most of the OCPs concentrations were high during cultivation period. The OCP concentrations of rainy season were highly correlated (p < 0.01) with OCPs of hot seasons. Further, positive correlation (p < 0.05) was also obtained between cold seasons and retreating monsoon. Principal component analysis showed a significant correlation among the four seasons and distribution pattern of OCPs in air. Back trajectory analysis by using HYPSLIT model showed a long range air transport of OCPs to the present study area. Present OCP levels at Manipur is an outcome of both local emission and also movement of air mass by long range atmospheric transport.

  3. An Inexpensive Autosampler to Maximize Throughput for an Ion Source that Samples Surfaces in Open Air

    EPA Science Inventory

    An autosampler was built to pull cotton swab heads mounted into a 3-foot long, square Al rod in ambient air through the He ionizing beam of a Direct Analysis in Real Time (DART) ion source interfaced to an orthogonal acceleration, time-of-flight mass spectrometer. The cost of th...

  4. 32 CFR 806.27 - Samples of Air Force FOIA processing documents.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... documents. (a) This section includes suggested language in paragraph format that tracks Air Force and DoD... section, language in parentheses is for explanatory purposes only. Do not include any of the parenthetical language of this section in your FOIA correspondence. When optional language must be selected, the...

  5. ASSESSMENT OF VAPOR INTRUSION USING INDOOR AND SUB-SLAB AIR SAMPLING

    EPA Science Inventory

    The objective of this investigation was to develop a method for evaluating vapor intrusion using indoor and sub-slab air measurement and at the same time directly assist EPA’s New England Regional Office in evaluating vapor intrusion in 15 homes and one business near the former R...

  6. Ambient Air Pollution and Depressive Symptoms in Older Adults: Results from the MOBILIZE Boston Study

    PubMed Central

    Wang, Yi; Eliot, Melissa N.; Koutrakis, Petros; Gryparis, Alexandros; Schwartz, Joel D.; Coull, Brent A.; Mittleman, Murray A.; Milberg, William P.; Lipsitz, Lewis A.

    2014-01-01

    Background: Exposure to ambient air pollution, particularly from traffic, has been associated with adverse cognitive outcomes, but the association with depressive symptoms remains unclear. Objectives: We investigated the association between exposure to ambient air and traffic pollution and the presence of depressive symptoms among 732 Boston-area adults ≥ 65 years of age (78.1 ± 5.5 years, mean ± SD). Methods: We assessed depressive symptoms during home interviews using the Revised Center for Epidemiological Studies Depression Scale (CESD-R). We estimated residential distance to the nearest major roadway as a marker of long-term exposure to traffic pollution and assessed short-term exposure to ambient fine particulate matter (PM2.5), sulfates, black carbon (BC), ultrafine particles, and gaseous pollutants, averaged over the 2 weeks preceding each assessment. We used generalized estimating equations to estimate the odds ratio (OR) of a CESD-R score ≥ 16 associated with exposure, adjusting for potential confounders. In sensitivity analyses, we considered CESD-R score as a continuous outcome and mean annual residential BC as an alternate marker of long-term exposure to traffic pollution. Results: We found no evidence of a positive association between depressive symptoms and long-term exposure to traffic pollution or short-term changes in pollutant levels. For example, we found an OR of CESD-R score ≥ 16 of 0.67 (95% CI: 0.46, 0.98) per interquartile range (3.4 μg/m3) increase in PM2.5 over the 2 weeks preceding assessment. Conclusions: We found no evidence suggesting that ambient air pollution is associated with depressive symptoms among older adults living in a metropolitan area in attainment of current U.S. regulatory standards. Citation: Wang Y, Eliot MN, Koutrakis P, Gryparis A, Schwartz JD, Coull BA, Mittleman MA, Milberg WP, Lipsitz LA, Wellenius GA. 2014. Ambient air pollution and depressive symptoms in older adults: results from the MOBILIZE Boston

  7. Water- and Air-Quality Monitoring of Sweetwater Reservoir Watershed, San Diego County, California - Phase One Results Continued, 2001-2003

    USGS Publications Warehouse

    Mendez, Gregory O.; Foreman, William T.; Morita, Andrew; Majewski, Michael S.

    2008-01-01

    In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to monitor water, air, and sediment at the Sweetwater and Loveland Reservoirs in San Diego County, California. The study includes regular sampling of water and air at Sweetwater Reservoir for chemical constituents, including volatile organic compounds (VOC), polynuclear aromatic hydrocarbons (PAH), pesticides, and major and trace elements. The purpose of this study is to monitor changes in contaminant composition and concentration during the construction and operation of State Route 125. To accomplish this, the study was divided into two phases. Phase One sampling (water years 1998-2004) determined baseline conditions for the detection frequency and the concentrations of target compounds in air and water. Phase Two sampling (starting water year 2005) continues at selected monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment may have on water quality in the reservoir. Water samples were collected for VOCs and pesticides at Loveland Reservoir during Phase One and will be collected during Phase Two for comparison purposes. Air samples collected to monitor changes in VOCs, PAHs, and pesticides were analyzed by adapting methods used to analyze water samples. Bed-sediment samples have been and will be collected three times during the study; at the beginning of Phase One, at the start of Phase Two, and near the end of the study. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as trace metals, anthropogenic indicator compounds, and pharmaceuticals. This report describes the study design, and the sampling and analytical methods, and presents data from water and air samples collected during the fourth and fifth years of Phase One of the study (October 2001 to September 2003). Data collected during the first three

  8. Results for the Fourth Quarter 2012 Tank 50 WAC Slurry Sample: Chemical and Radionuclide Contaminants

    SciTech Connect

    Bannochie, Christopher J.

    2014-09-30

    This report details the chemical and radionuclide contaminant results for the characterization of the 2012 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC).1 Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: The concentration of the reported chemical and radioactive contaminants were less than their respective WAC Limits and Targets, unless noted in this section. Norpar 13 and Isopar L have higher detection limits5 compared with the Saltstone WAC1. The data provided in this report is based upon the concentrations in the sub-sample, and due to the limited solubility in aqueous solution, may not represent the concentrations of the analytes in Tank 50. Diisooctyl adipate (or diisooctyl hexanedioate) was measured at 1.30E+00 mg/L in one of two replicate measurements conducted on an at-depth sample.a The organic analysis of the at-depth sample was conducted at the request of SRR.4 This analyte was below the detection limit in the surface sample. The low insoluble solids content increases the measurement uncertainty for insoluble species.

  9. Tank 241-TY-104 headspace gas and vapor characterization results for samples collected in April 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  10. Tank 241-C-104 headspace gas and vapor characterization results for samples collected in March 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-28

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  11. Tank 241-AX-102 headspace gas and vapor characterization results for samples collected in June 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  12. Tank 241-SX-106 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  13. Tank 241-SX-103 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  14. Tank 241-A-101 headspace gas and vapor characterization results for samples collected in June 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  15. Tank 241-T-107 Headspace Gas and Vapor Characterization Results for Samples Collected in January 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-26

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

  16. Tank 241-T-111 headspace gas and vapor characterization results for samples collected in January 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  17. Tank 241-C-101 headspace gas and vapor characterization results for samples collected in September 1994

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  18. Tank 241-S-111 headspace gas and vapor characterization results for samples collected in March 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  19. Tank 241-U-107 headspace gas and vapor characterization results for samples collected in February 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

  20. Tank 241-U-111 headspace gas and vapor characterization results for samples collected in February 1995

    SciTech Connect

    Huckaby, J.L.; Bratzel, D.R.

    1995-09-01

    Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.