Science.gov

Sample records for air stripping tower

  1. Cross-flow versus counterflow air-stripping towers

    SciTech Connect

    Little, J.C.; Marinas, B.J.

    1997-07-01

    Mass-transfer and pressure-drop packing performance correlations are used together with tower design equations and detailed cost models to compare the effectiveness of cross-flow and counterflow air stripping towers over a wide range of contaminant volatility. Cross-flow towers are shown to offer a significant economic advantage over counterflow towers when stripping low volatility organic contaminants primarily due to savings in energy costs. These savings increase as contaminant volatility decreases and as water flow rate increases. A further advantage of the cross-flow configuration is that it extends the feasible operating range for air stripping as cross-flow towers can accommodate higher air-to-water flow ratios than conventional counterflow towers. Finally it is shown that the optimized least-cost design for both counterflow and cross-flow towers varies with Henry`s law constant, water flow rate, and percent removal, but that the optimum is virtually insensitive to other cost and operating variables. This greatly simplifies the tower design procedure.

  2. Stripping of phenols in model cooling towers

    SciTech Connect

    Turner, C.D.; Moe, T.A.; Wentz, C.A.

    1987-01-01

    Cooling towers are used to remove waste heat from unit operations in chemical processing plants. Using cooling towers for wastewater treatment and disposal through internal recycling has become an important alternative because of stricter wastewater discharge standards, the expense of specialized wastewater treatment systems and the limited availability and cost of water in arid regions. Designs for synfuels plants must address the problem of wastewater disposal. Alternative systems under consideration usually include zero discharge designs that incorporate evaporative cooling towers in the system. The mechanisms for contaminant removal in cooling towers are biological oxidation, stripping and chemical precipitation. Chemical precipitation is generally considered undesirable because of losses in heat transfer efficiency. Predicting whether stripping or biological oxidation will be the primary removal mechanism for phenolic compounds from coal conversion wastewaters used as makeup in cooling towers does not appear to be possible based on the results of these tests. The tests do indicate that the biological oxidation of phenol is possible in forced draft cooling towers.

  3. Membrane air-stripping: Effects of pretreatment

    SciTech Connect

    Castro, K. ); Zander, A.K. . Dept. of Civil and Environmental Engineering)

    1995-03-01

    As a result of the Safe Drinking Water Act and its 1986 amendments, the number of regulated volatile organic chemicals (VOCs) has increased substantially. The discovery of drinking water supply sources contaminated by VOCs is also increasing. These factors have led to the development of alternative treatment methods for control of VOCs. Microporous polypropylene hollow-fiber membranes offer significant advantages over packed-tower aeration for removing volatile organic chemicals. A laboratory study assessed the performance of membrane air-stripping in continuous operation, while exposed to various pretreatments. Results indicate that membrane air-stripping is compatible with low-pH or low-chlorine waters but not with waters of high pH or high-chlorine concentration or those that are ozonated.

  4. Ammonia removal from landfill leachate by air stripping and absorption.

    PubMed

    Ferraz, Fernanda M; Povinelli, Jurandyr; Vieira, Eny Maria

    2013-01-01

    An old landfill leachate was pre-treated in a pilot-scale aerated packed tower operated in batch mode for total ammoniacal nitrogen (TAN) removal. The stripped ammonia was recovered with a 0.4 mol L(-1) H2SO4 solution, deionized water and tap water. Ca(OH)2 (95% purity) or commercial hydrated lime was added to the raw leachate to adjust its pH to 11, causing removal of colour (82%) and heavy metals (70-90% for Zn, Fe and Mn). The 0.4 molL(-1) H2SO4 solution was able to neutralize 80% of the stripped ammonia removed from 12 L of leachate. The effectiveness of the neutralization of ammonia with deionized water was 75%. Treating 100 L of leachate, the air stripping tower removed 88% of TAN after 72 h of aeration, and 87% of the stripped ammonia was recovered in two 31 L pilot-scale absorption units filled with 20 L of tap water. PMID:24350487

  5. ENGINEERING BULLETIN: AIR STRIPPING OF AQUEOUS SOLUTIONS

    EPA Science Inventory

    Air striding is a means to transfer contaminants from aqueous solutions to air. ontaminants are not destroyed by air stripping but are physically separated from the aqueous solutions. ontaminant vapors are transferred into the air stream and, if necessary, can be treated by incin...

  6. Air stripping. (Latest citations from the NTIS database). Published Search

    SciTech Connect

    Not Available

    1993-04-01

    The bibliography contains citations concerning the application of air stripping techniques to water treatment, including groundwater decontamination and wastewater purification. The advantages and disadvantages of air stripping over other water treatment processes are discussed. Cleanup of the organic emissions generated by air stripping is also considered. The primary applications of air stripping are in groundwater and soil cleanup. (Contains a minimum of 71 citations and includes a subject term index and title list.)

  7. Dimensions of Air Traffic Control Tower Information Needs: From Information Requests to Display Design

    ERIC Educational Resources Information Center

    Durso, Francis T.; Johnson, Brian R.; Crutchfield, Jerry M.

    2010-01-01

    In an effort to determine the information needs of tower air traffic controllers, instructors from the Federal Aviation Administration's Academy in Oklahoma City were asked to control traffic in a high-fidelity tower cab simulator. Information requests were made apparent by eliminating access to standard tower information sources. Instead,…

  8. INSECTICIDE CONCENTRATIONS IN AIR AFTER APPLICATION OF PEST CONTROL STRIPS

    EPA Science Inventory

    Contamination of air in homes due to spraying of pesticides is of concern to the public. A pest control strip which kills creeping and crawling insects by contact is one method of reducing the amount of insecticide in the air. Several different insecticides are now available in t...

  9. Distillation and Air Stripping Designs for the Lunar Surface

    NASA Technical Reports Server (NTRS)

    Boul, Peter J.; Lange, Kevin E.; Conger, Bruce; Anderson, Molly

    2009-01-01

    Air stripping and distillation are two different gravity-based methods, which may be applied to the purification of wastewater on the lunar base. These gravity-based solutions to water processing are robust physical separation techniques, which may be advantageous to many other techniques for their simplicity in design and operation. The two techniques can be used in conjunction with each other to obtain high purity water. The components and feed compositions for modeling waste water streams are presented in conjunction with the Aspen property system for traditional stage distillation models and air stripping models. While the individual components for each of the waste streams will vary naturally within certain bounds, an analog model for waste water processing is suggested based on typical concentration ranges for these components. Target purity levels for the for recycled water are determined for each individual component based on NASA s required maximum contaminant levels for potable water Distillation processes are modeled separately and in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Optimum parameters such as reflux ratio, feed stage location, and processing rates are determined with respect to the power consumption of the process. Multistage distillation is evaluated for components in wastewater to determine the minimum number of stages necessary for each of 65 components in humidity condensate and urine wastewater mixed streams. Components of the wastewater streams are ranked by Henry s Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support

  10. Air stripping. (Latest citations from the NTIS bibliographic database). Published Search

    SciTech Connect

    1997-03-01

    The bibliography contains citations concerning the application of air stripping techniques to water treatment, including groundwater decontamination and wastewater purification. The advantages and disadvantages of air stripping over other water treatment processes are discussed. Cleanup of the organic emissions generated by air stripping is also considered. The primary applications of air stripping are in groundwater and soil cleanup. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  11. Air stripping. (Latest citations from the NTIS bibliographic database). Published Search

    SciTech Connect

    1995-02-01

    The bibliography contains citations concerning the application of air stripping techniques to water treatment, including groundwater decontamination and wastewater purification. The advantages and disadvantages of air stripping over other water treatment processes are discussed. Cleanup of the organic emissions generated by air stripping is also considered. The primary applications of air stripping are in groundwater and soil cleanup. (Contains a minimum of 89 citations and includes a subject term index and title list.)

  12. Simulations of in situ air stripping demonstration at Savannah River

    SciTech Connect

    Robinson, B.A.; Rosenberg, N.D.; Zyvoloski, G.A.; Viswanathan, H.

    1994-06-01

    This report assesses the performance of the in situ air stripping technology demonstrated at the Savannah River Integrated Demonstration (SRID) site. This technology is a combination of air injection below the water table and vacuum extraction in the vadose zone, using a pair of horizontal wells. Our approach is based on the construction of a site-specific numerical model using the FEHM flow and transport code. We use the model as a tool to investigate improvements to performance, to improve the prediction of the performance of this technology over longer periods of time and at different sites, and to compare performance with other remediation technologies.

  13. Convection towers

    DOEpatents

    Prueitt, Melvin L.

    1994-01-01

    Convection towers which are capable of cleaning the pollution from large quantities of air and of generating electricity utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity. Other embodiments may also provide fresh water, and operate in an updraft mode.

  14. Convection towers

    DOEpatents

    Prueitt, Melvin L.

    1996-01-01

    Convection towers which are capable of cleaning the pollution from large quantities of air, of generating electricity, and of producing fresh water utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity, and condensers produce fresh water.

  15. Convection towers

    DOEpatents

    Prueitt, Melvin L.

    1995-01-01

    Convection towers which are capable of cleaning the pollution from large quantities of air, of generating electricity, and of producing fresh water utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity, and condensers produce fresh water.

  16. Convection towers

    DOEpatents

    Prueitt, M.L.

    1996-01-16

    Convection towers which are capable of cleaning the pollution from large quantities of air, of generating electricity, and of producing fresh water utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity, and condensers produce fresh water. 6 figs.

  17. Using in-situ hot air/steam stripping (HASS) of hydrocarbons in soils

    SciTech Connect

    La Mori, P.N.

    1994-12-31

    The remediation of soils containing volatile (VOC) and semi-volatile (SVC) hydrocarbons is most desirably accomplished in-situ, i.e., without removal of the contaminated soils from the ground. This approach mitigates the environmental problem, i.e., does not transport it to another location, and when properly applied, does not impact on the local environment during remediation NOVATERRA has demonstrated commercially an in-situ, hot air/steam stripping (HASS) technology to remove VOC and SVC from soils both in the vadose and saturated zones. The technology consists of a drill tower which injects and mixes steam and hot air continuously into the soil below ground and a method to immediately capture all vapors escaping to the surface and remove the vaporized VOC/SVC using condensation and carbon beds. The air can be recompressed and recycled. The condensed liquid containing hydrocarbons is purified by distillation. The recovered hydrocarbons can be destroyed or recycled. The technology has successfully removed various chlorinated aliphatics and aromatics, glycol ethers, phthalates, polyaromatic compounds, ketones, petroleum hydrocarbons and many other compound types from sand to clay soils to risk based standards; e.g. 1 increased cancer risk in 1,000,000 using currently acceptable risk assessment standards.

  18. Modeling Air Stripping of Ammonia in an Agitated Vessel

    SciTech Connect

    Kofi, Adu-Wusu; Martino, Christopher J.; Wilmarth, William R.; Bennett, William M.; Peters, Robert s.

    2005-11-29

    A model has been developed to predict the rate of removal of ammonia (NH{sub 3}) from solution in a sparged agitated vessel. The model is first-order with respect to liquid-phase concentration of NH{sub 3}. The rate constant for the first-order equation is a function of parameters related to the vessel/impeller characteristics, the air/liquid properties as well as the process conditions. However, the vessel/impeller characteristics, the air/liquid properties, and the process conditions reduce the rate constant dependence to only three parameters, namely, the air sparge rate, the liquid volume or batch size, and the Henry's law constant of NH{sub 3} for the liquid or solution. Thus, the rate of removal is not mass-transfer limited. High air sparge rates, high temperatures, and low liquid volumes or batch sizes increase the rate of removal of NH{sub 3} from solution. The Henry's law constant effect is somewhat reflected in the temperature since Henry's law constant increases with increasing temperature. Data obtained from actual air stripping operation agree fairly well with the model predictions.

  19. Convection towers

    DOEpatents

    Prueitt, M.L.

    1994-02-08

    Convection towers which are capable of cleaning the pollution from large quantities of air and of generating electricity utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity. Other embodiments may also provide fresh water, and operate in an updraft mode. 5 figures.

  20. Evaluation and quantification of the impact of cooling tower emissions on indoor air quality

    SciTech Connect

    Vanderheyden, M.D.; Schuyler, G.D.

    1994-12-31

    Assessment of the potential impact of outdoor pollutant sources on indoor air quality through the reentrainment of pollutants vis-a-vis air-handling units, doorways, and windows has mainly focused on the evaluation of fume hood, boiler, diesel generator, and vehicular pollutant emissions. In recent years, however, gaseous and waterborne pollutants emitted from cooling towers have become an increasing source of concern. Chemicals such as biocides and corrosion and scale inhibitors are used to reduce and/or eliminate algae blooms, decrease bacterial and fungal growth, and reduce the corrosion of equipment. When added to the water used in cooling towers, these chemicals are emitted in both the gaseous phase and as pollutants dissolved in or suspended in water droplets. A qualitative evaluation of exhaust dispersion and droplet deposition rates associated with cooling towers is necessary when conducting an overall review of the environmental impact on indoor air quality. This paper identifies source emission rates to be used in assessing emissions of chemical additives in cooling towers, presents provisional design criteria for evaluating the impact of the chemical additives, and evaluates alternative methodologies for quantifying impact concentrations. These alternative assessment methodologies include numerical models, physical wind tunnel simulations, and computational fluid dynamics (CFD) simulations. Parameters used in comparing the methodologies include relative accuracy (order of magnitude) and modeling and simulation limitations.

  1. Optimization research on the structure of horizontally-arranged indirect air-cooling tower under strong wind condition

    NASA Astrophysics Data System (ADS)

    Chen, Guoyong; Gu, Hongfang; Wang, Haijun; Qin, Yongbo

    2013-07-01

    Strong wind has a significant impact on the heat radiation of the air-cooling system. In this research, a numerical calculation model of 2×1000MW horizontally arranged air-cooling tower is established to simulate the flow distribution and heat exchanging capability of three different structures-horizontally-arranged indirect air-cooling tower, tower with guide wall outside, and tower with a cross wall inside-under high-speed wind and extreme-speed wind conditions. The result reveals that the structure with the guide wall outside the tower only works under strong wind condition while the structure with cross wall inside shows the anti-wind capability under both high-speed wind and extreme-speed wind conditions.

  2. Information Presentation and Control in a Modern Air Traffic Control Tower Simulator

    NASA Technical Reports Server (NTRS)

    Haines, Richard F.; Doubek, Sharon; Rabin, Boris; Harke, Stanton

    1996-01-01

    The proper presentation and management of information in America's largest and busiest (Level V) air traffic control towers calls for an in-depth understanding of many different human-computer considerations: user interface design for graphical, radar, and text; manual and automated data input hardware; information/display output technology; reconfigurable workstations; workload assessment; and many other related subjects. This paper discusses these subjects in the context of the Surface Development and Test Facility (SDTF) currently under construction at NASA's Ames Research Center, a full scale, multi-manned, air traffic control simulator which will provide the "look and feel" of an actual airport tower cab. Special emphasis will be given to the human-computer interfaces required for the different kinds of information displayed at the various controller and supervisory positions and to the computer-aided design (CAD) and other analytic, computer-based tools used to develop the facility.

  3. Air Stripping Designs and Reactive Water Purification Processes for the Lunar Surface

    NASA Technical Reports Server (NTRS)

    Boul, Peter J.; Lange, Kevin; Conger, Bruce; Anderson, Molly

    2010-01-01

    Air stripping designs are considered to reduce the presence of volatile organic compounds in the purified water. Components of the wastewater streams are ranked by Henry's Law Constant and the suitability of air stripping in the purification of wastewater in terms of component removal is evaluated. Distillation processes are modeled in tandem with air stripping to demonstrate the potential effectiveness and utility of these methods in recycling wastewater on the Moon. Scaling factors for distillation and air stripping columns are presented to account for the difference in the lunar gravitation environment. Commercially available distillation and air stripping units which are considered suitable for Exploration Life Support are presented. The advantages to the various designs are summarized with respect to water purity levels, power consumption, and processing rates. An evaluation of reactive distillation and air stripping is presented with regards to the reduction of volatile organic compounds in the contaminated water and air. Among the methods presented, an architecture is presented for the evaluation of the simultaneous oxidation of organics in air and water. These and other designs are presented in light of potential improvements in power consumptions and air and water purities for architectures which include catalytic activity integrated into the water processor. In particular, catalytic oxidation of organics may be useful as a tool to remove contaminants that more traditional distillation and/or air stripping columns may not remove. A review of the current leading edge at the commercial level and at the research frontier in catalytically active materials is presented. Themes and directions from the engineering developments in catalyst design are presented conceptually in light of developments in the nanoscale chemistry of a variety of catalyst materials.

  4. Development Of Chemical Reduction And Air Stripping Processes To Remove Mercury From Wastewater

    SciTech Connect

    Jackson, Dennis G.; Looney, Brian B.; Craig, Robert R.; Thompson, Martha C.; Kmetz, Thomas F.

    2013-07-10

    This study evaluates the removal of mercury from wastewater using chemical reduction and air stripping using a full-scale treatment system at the Savannah River Site. The existing water treatment system utilizes air stripping as the unit operation to remove organic compounds from groundwater that also contains mercury (C ~ 250 ng/L). The baseline air stripping process was ineffective in removing mercury and the water exceeded a proposed limit of 51 ng/L. To test an enhancement to the existing treatment modality a continuous dose of reducing agent was injected for 6-hours at the inlet of the air stripper. This action resulted in the chemical reduction of mercury to Hg(0), a species that is removable with the existing unit operation. During the injection period a 94% decrease in concentration was observed and the effluent satisfied proposed limits. The process was optimized over a 2-day period by sequentially evaluating dose rates ranging from 0.64X to 297X stoichiometry. A minimum dose of 16X stoichiometry was necessary to initiate the reduction reaction that facilitated the mercury removal. Competing electron acceptors likely inhibited the reaction at the lower 1 doses, which prevented removal by air stripping. These results indicate that chemical reduction coupled with air stripping can effectively treat large-volumes of water to emerging part per trillion regulatory standards for mercury.

  5. Dimensions of air traffic control tower information needs: from information requests to display design.

    PubMed

    Durso, Francis T; Johnson, Brian R; Crutchfield, Jerry M

    2010-09-01

    In an effort to determine the information needs of tower air traffic controllers, instructors from the Federal Aviation Administration's Academy in Oklahoma City were asked to control traffic in a high-fidelity tower cab simulator. Information requests were made apparent by eliminating access to standard tower information sources. Instead, controllers were required to ask for precisely the information they needed during the scenarios. The information requests were classified using an elaboration of Zwaan and Radvansky's (1998) dimensions of situation models. The vast majority of requests were about three of the dimensions originally developed for reading comprehension: the protagonist, intentionality, and space. The information requests were also classified into 28 operational categories (e.g., aircraft identification, destination). From these results, the data were summarized, not just statistically, but by the creation of display-hypotheses. The display-hypotheses were organized according to the situation-model dimensions. Controllers preferred data blocks organized by the situation-model principle over those that violated this organization. The summary display-hypotheses were quite simple and accounted for the vast majority of the information requests controllers made. The display-hypotheses accounted for the information needs of controllers during routine as well as off-nominal events. PMID:20853983

  6. In situ air stripping using horizontal wells. Innovative technology summary report

    SciTech Connect

    1995-04-01

    In-situ air stripping employs horizontal wells to inject or sparge air into the ground water and vacuum extract VOC`S from vadose zone soils. The horizontal wells provide better access to the subsurface contamination, and the air sparging eliminates the need for surface ground water treatment systems and treats the subsurface in-situ. A full-scale demonstration was conducted at the Savannah River Plant in an area polluted with trichloroethylene and tetrachloroethylene. Results are described.

  7. Innovative technology summary report: in situ air stripping using horizontal wells

    SciTech Connect

    1995-04-01

    In situ air stripping (ISAS) technology was developed to remediate soils and ground water contaminated with volatile organic compounds (VOCs) both above and below the water table. ISAS employs horizontal wells to inject (sparge) air into the ground water and vacuum extract VOCs from vadose zone soils. The innovation is creation of a system that combines two somewhat innovative technologies, air sparging and horizontal wells, with a baseline technology, soil vapor extraction, to produce a more efficient in situ remediation system.

  8. Hydrophilic strips for preventing air bubble formation in a microfluidic chamber.

    PubMed

    Choi, Munseok; Na, Yang; Kim, Sung-Jin

    2015-12-01

    In a microfluidic chamber, unwanted formation of air bubbles is a critical problem. Here, we present a hydrophilic strip array that prevents air bubble formation in a microfluidic chamber. The array is located on the top surface of the chamber, which has a large variation in width, and consists of a repeated arrangement of super- and moderately hydrophilic strips. This repeated arrangement allows a flat meniscus (i.e. liquid front) to form when various solutions consisting of a single stream or two parallel streams with different hydrophilicities move through the chamber. The flat meniscus produced by the array completely prevents the formation of bubbles. Without the array in the chamber, the meniscus shape is highly convex, and bubbles frequently form in the chamber. This hydrophilic strip array will facilitate the use of a microfluidic chamber with a large variation in width for various microfluidic applications. PMID:26382942

  9. APPLICATIONS ANALYSIS REPORT: TOXIC TREATMENTS, IN-SITU STEAM/HOT-AIR STRIPPING TECHNOLOGY

    EPA Science Inventory

    This document is an evaluation of the performance of the Toxic Treatments (USA), Inc., (TTUSA) in situ steam/hot-air stripping technology and its applicability as an on-site treatment technique for hazardous waste site soil cleanup of volatile and semivolatile contaminants. Both ...

  10. DEMONSTRATION BULLETIN: IN-SITU STEAM/HOT AIR SOIL STRIPPING TOXIC TREATMENT (USA) INC.

    EPA Science Inventory

    This technology uses steam and hot air to strip volatile organics from contaminated soil. The treatment equipment is mobile and treats the soil in-situ without need for soil excavation or transportation. The organic contaminants volatilized from the soil are condensed and col...

  11. INTEGRATION OF PHOTOCATALYTIC OXIDATION WITH AIR STRIPPING OF CONTAMINATED AQUIFERS

    EPA Science Inventory

    Bench scale laboratory studies and pilot scale studies in a simulated field-test situation were performed to evaluate the integration of gas-solid ultaviolet (UV) photocatalytic oxidation (PCO) downstream if an air stripper unit as a technology for cost-effectively treating water...

  12. Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2008-04-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

  13. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    SciTech Connect

    Robert Hayes

    2009-01-23

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level.

  14. Startup of air-cooled condensers and dry cooling towers at low temperatures of the cooling air

    NASA Astrophysics Data System (ADS)

    Milman, O. O.; Ptakhin, A. V.; Kondratev, A. V.; Shifrin, B. A.; Yankov, G. G.

    2016-05-01

    The problems of startup and performance of air-cooled condensers (ACC) and dry cooling towers (DCT) at low cooling air temperatures are considered. Effects of the startup of the ACC at sub-zero temperatures are described. Different options of the ACC heating up are analyzed, and examples of existing technologies are presented (electric heating, heating up with hot air or steam, and internal and external heating). The use of additional heat exchanging sections, steam tracers, in the DCT design is described. The need for high power in cases of electric heating and heating up with hot air is noted. An experimental stand for research and testing of the ACC startup at low temperatures is described. The design of the three-pass ACC unit is given, and its advantages over classical single-pass design at low temperatures are listed. The formation of ice plugs inside the heat exchanging tubes during the start-up of ACC and DCT at low cooling air temperatures is analyzed. Experimental data on the effect of the steam flow rate, steam nozzle distance from the heat-exchange surface, and their orientation in space on the metal temperature were collected, and test results are analyzed. It is noted that the surface temperature at the end of the heat up is almost independent from its initial temperature. Recommendations for the safe start-up of ACCs and DCTs are given. The heating flow necessary to sufficiently heat up heat-exchange surfaces of ACCs and DCTs for the safe startup is estimated. The technology and the process of the heat up of the ACC with the heating steam external supply are described by the example of the startup of the full-scale section of the ACC at sub-zero temperatures of the cooling air, and the advantages of the proposed start-up technology are confirmed.

  15. Evaporation and air-stripping to assess and reduce ethanolamines toxicity in oily wastewater.

    PubMed

    Libralato, G; Ghirardini, A Volpi; Avezzù, F

    2008-05-30

    Toxicity from industrial oily wastewater remains a problem even after conventional activated sludge treatment process, because of the persistence of some toxicant compounds. This work verified the removal efficiency of organic and inorganic pollutants and the effects of evaporation and air-stripping techniques on oily wastewater toxicity reduction. In a lab-scale plant, a vacuum evaporation procedure at three different temperatures and an air-stripping stage were tested on oily wastewater. Toxicity reduction/removal was observed at each treatment step via Microtox bioassay. A case study monitoring real scale evaporation was also done in a full-size wastewater treatment plant (WWTP). To implement part of a general project of toxicity reduction evaluation, additional investigations took into account the monoethanolamine (MEA), diethanolamine (DEA) and triethanolamine (TEA) role in toxicity definition after the evaporation phase, both as pure substances and mixtures. Only MEA and TEA appeared to contribute towards effluent toxicity. PMID:17980956

  16. Reactive Distillation and Air Stripping Processes for Water Recycling and Trace Contaminant Control

    NASA Technical Reports Server (NTRS)

    Boul, Peter J.; Lange, Kevin E.; Conger, Bruce; Anderson, Molly

    2009-01-01

    Reactive distillation designs are considered to reduce the presence of volatile organic compounds in the purified water. Reactive distillation integrates a reactor with a distillation column. A review of the literature in this field has revealed a variety of functional reactive columns in industry. Wastewater may be purified by a combination of a reactor and a distiller (e.g., the EWRS or VPCAR concepts) or, in principle, through a design which integrates the reactor with the distiller. A review of the literature in reactive distillation has identified some different designs in such combinations of reactor and distiller. An evaluation of reactive distillation and reactive air stripping is presented with regards to the reduction of volatile organic compounds in the contaminated water and air. Among the methods presented, an architecture is presented for the evaluation of the simultaneous oxidation of organics in air and water. These and other designs are presented in light of potential improvements in power consumptions and air and water purities for architectures which include catalytic activity integrated into the water processor. In particular, catalytic oxidation of organics may be useful as a tool to remove contaminants that more traditional distillation and/or air stripping columns may not remove. A review of the current leading edge at the commercial level and at the research frontier in catalytically active materials is presented. Themes and directions from the engineering developments in catalyst design are presented conceptually in light of developments in the nanoscale chemistry of a variety of catalyst materials.

  17. Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait.

    PubMed

    Al-Matawah, Qadreyah; Al-Zenki, Sameer; Al-Azmi, Ahmad; Al-Waalan, Tahani; Al-Salameen, Fadila; Hejji, Ahmad Ben

    2015-07-01

    The main aim of the study was to test for the presence of Legionnaires' disease-causing microorganisms in air-conditioned buildings in Kuwait using molecular technologies. For this purpose, 547 samples were collected from 38 cooling towers for the analysis of Legionella pneumophila. These samples included those from water (n = 178), air (n = 231), and swabs (n = 138). Out of the 547 samples, 226 (41%) samples were presumptive positive for L. pneumophila, with L. pneumophila viable counts in the positive water samples ranging from 1 to 88 CFU/ml. Of the Legionella culture-positive samples, 204 isolates were examined by latex agglutination. These isolates were predominately identified as L. pneumophila serogroup (sg) 2-14. Using the Dresden panel of monoclonal antibodies, 74 representatives isolates were further serogrouped. Results showed that 51% of the isolates belonged to serogroup 7 followed by 1 (18%) and 3 (18%). Serogroups 4 (4%) and 10 (7%) were isolated at a lower frequency, and two isolates could not be assigned to a serogroup. These results indicate the wide prevalence of L. pneumophila serogroup 7 as the predominant serogroup at the selected sampling sites. Furthermore, the 74 L. pneumophila (sg1 = 13; sg3 = 13; sg4 = 3; sg7 = 38; sg10 = 5; sgX = 2) isolates were genotyped using the seven gene protocol sequence-based typing (SBT) scheme developed by the European Working Group for Legionella Infections (EWGLI). The results show that Legionella isolates were discriminated into nine distinct sequence typing (ST) profiles, five of which were new to the SBT database of EWGLI. Additionally, all of the ST1 serogroup 1 isolates were of the OLDA/Oxford subgroup. These baseline data will form the basis for the development of a Legionella environmental surveillance program and used for future epidemiological investigations. PMID:25701245

  18. Application of pig slurry to soils. Effect of air stripping treatment on nitrogen and TOC leaching.

    PubMed

    Bolado-Rodríguez, Silvia; García-Sinovas, David; Alvarez-Benedí, Javier

    2010-12-01

    The effect of physical-chemical slurry treatment on the mobility and transformation of nitrogen and organic matter from pig slurry after soil application is evaluated. Two different pig slurries (one treated by stripping with air at pH=9 and another non-treated) were applied at the top of a soil column, containing approximately 100 kg of soil. Effluents were monitored measuring concentration values of ammonia, nitrites, nitrates and total organic carbon (TOC). The breakthrough curves were modelled using STANMOD and HYDRUS 1D codes. Low concentrations of ammonia were detected in the effluent recovered at the bottom of the soil profile for both types of slurry. Nitrate concentration in effluent was lower and more homogenous over time when applying stripping treated pig slurry. In N modelling, adsorption of ammonia by soil proved an important process, nitrite and nitrate adsorption being less significant, although not negligible. Transformation from ammonia to nitrite controls the kinetics of the nitrification process. Total organic carbon in the column effluent was higher in the experiment using treated pig slurry, which can be attributed to organic matter solubilisation in the stripping treatment process. PMID:20705384

  19. Influence of liquid and gas flow rates on sulfuric acid mist removal from air by packed bed tower

    PubMed Central

    2012-01-01

    The possible emission of sulfuric acid mists from a laboratory scale, counter-current packed bed tower operated with a caustic scrubbing solution was studied. Acid mists were applied through a local exhaust hood. The emissions from the packed bed tower were monitored in three different categories of gas flow rate as well as three liquid flow rates, while other influencing parameters were kept almost constant. Air sampling and sulfuric acid measurement were carried out iso-kinetically using USEPA method 8. The acid mists were measured by the barium-thorin titration method. According to the results when the gas flow rate increased from 10 L/s to 30 L/s, the average removal efficiency increased significantly (p < 0.001) from 76.8 ± 1.8% to 85.7 ± 1.2%. Analysis of covariance method followed by Tukey post-hoc test of 92 tests did not show a significant change in removal efficiency between liquid flow rates of 1.5, 2.5 and 3.5 L/min (p = 0.811). On the other hand, with fixed pressure loss across the tower, by increasing the liquid/gas (L/G) mass ratio, the average removal efficiency decreased significantly (p = 0.001) from 89.9% at L/G of <2 to 83.1% at L/G of 2–3 and further to 80.2% at L/G of >3, respectively. L/G of 2–3 was recommended for designing purposes of a packed tower for sulfuric acid mists and vapors removal from contaminated air stream. PMID:23369487

  20. 76 FR 490 - Marking Meteorological Evaluation Towers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-05

    ...-2251. FOR FURTHER INFORMATION CONTACT: Sheri Edgett-Barron, Obstruction Evaluation Services, Air... Federal Aviation Administration 14 CFR Part 77 Marking Meteorological Evaluation Towers AGENCY: Federal... to include guidance for Meteorological Evaluation Towers (METs). These towers are erected in...

  1. Stomatal Opening in Isolated Epidermal Strips of Vicia faba. I. Response to Light and to CO2-free Air 1

    PubMed Central

    Fischer, R. A.

    1968-01-01

    This paper reports a consistent and large opening response to light + CO2-free air in living stomata of isolated epidermal strips of Vicia faba. The response was compared to that of non-isolated stomata in leaf discs floating on water; stomatal apertures, guard cell solute potentials and starch contents were similar in the 2 situations. To obtain such stomatal behavior, it was necessary to float epidermal strips on dilute KCl solutions. This suggests that solute uptake is necessary for stomatal opening. The demonstration of normal stomatal behavior in isolated epidermal strips provides a very useful system in which to investigate the mechanism of stomatal opening. It was possible to show independent responses in stomatal aperture to light and to CO2-free air. PMID:16656995

  2. A study of air-to-ground sound propagation using an instrumented meteorological tower

    NASA Technical Reports Server (NTRS)

    Kasper, P. K.; Pappa, R. S.; Keefe, L. R.; Sutherland, L. C.

    1975-01-01

    The results of an exploratory NASA study, leading to a better understanding of the effects of meteorological conditions on the propagation of aircraft noise, are reported. The experimental program utilized a known sound source fixed atop an instrumented meteorological tower. The basic experimental scheme consisted of measuring the amplitude of sound radiated toward the ground along a line of microphones fixed to a tower guy wire. Experimental results show the feasibility of this approach in the acquisition of data indicating the variations encountered in the time-averaged and instantaneous amplitudes of propagated sound. The investigation included a consideration of ground reflections, a comparison of measured attenuations with predicted atmospheric absorption losses, and an evaluation of the amplitude fluctuations of recorded sound pressures.

  3. Use of Oriented Spray Nozzles to Set the Vapor-Air Flow in Rotary Motion in the Superspray Space of the Evaporative Chimney-Type Tower

    NASA Astrophysics Data System (ADS)

    Dobrego, K. V.; Davydenko, V. F.; Koznacheev, I. A.

    2016-01-01

    The present paper considers the problem of upgrading the thermal efficiency of chimney-type evaporative cooling towers due to the rotary motion of the vapor-air flow in the superspray space. To set the vapor-air flow in rotary motion, we propose to use the momentum of the sprayed water. It has been shown that the existing parameters of spray nozzles permit setting up to 30% of the water flow momentum in translatory motion, which is enough for changing considerably the aerodynamics of the vapor-air flow in the superspray space and improving the operation of the cooling tower. The optimal angle of axial inclination of the spray cone has been estimated. Recommendations are given and problems have been posed for engineering realization of the proposed technologies in a chimney-type cooling tower.

  4. Ground water and soil remediation: In situ air stripping using horizontal wells

    SciTech Connect

    Kaback, D.S.; Looney, B.B.; Eddy, C.A.; Hazen, T.C.

    1990-01-01

    An innovative environmental restoration technology, in situ air stripping, has been demonstrated at the US Department of Energy (DOE) Savannah River Site (SRS) in South Carolina. This process, using horizontal wells, is designed to concurrently remediate unsaturated-zone soils and ground water containing Volatile Organic Compounds (VOC). In situ technologies have the potential to substantially reduce costs and time required for remediation as well as improve effectiveness of remediation. Horizontal wells were selected to deliver and extract fluids from the subsurface because their geometry can maximize the efficiency of a remediation system and they have great potential for remediating contaminant sources under existing facilities. The first demonstration of this new technology was conducted for a period of twenty weeks. A vacuum was first drawn on the vadose zone well until a steady-state removal of VOCs was obtained. Air was then injected at three different rates and at two different temperatures. An extensive characterization program was conducted at the site and an extensive monitoring network was installed prior to initiation of the test. Significant quantities of VOCs have been removed from the subsurface (equivalent to an eleven-well, 500-gpm, pump-and-treat system at the same site). Concentrations of VOCs in the ground water have been significantly reduced in a number of the monitoring wells.

  5. Ground water and soil remediation: In situ air stripping using horizontal wells

    SciTech Connect

    Kaback, D.S.; Looney, B.B.; Eddy, C.A.; Hazen, T.C.

    1990-12-31

    An innovative environmental restoration technology, in situ air stripping, has been demonstrated at the US Department of Energy (DOE) Savannah River Site (SRS) in South Carolina. This process, using horizontal wells, is designed to concurrently remediate unsaturated-zone soils and ground water containing Volatile Organic Compounds (VOC). In situ technologies have the potential to substantially reduce costs and time required for remediation as well as improve effectiveness of remediation. Horizontal wells were selected to deliver and extract fluids from the subsurface because their geometry can maximize the efficiency of a remediation system and they have great potential for remediating contaminant sources under existing facilities. The first demonstration of this new technology was conducted for a period of twenty weeks. A vacuum was first drawn on the vadose zone well until a steady-state removal of VOCs was obtained. Air was then injected at three different rates and at two different temperatures. An extensive characterization program was conducted at the site and an extensive monitoring network was installed prior to initiation of the test. Significant quantities of VOCs have been removed from the subsurface (equivalent to an eleven-well, 500-gpm, pump-and-treat system at the same site). Concentrations of VOCs in the ground water have been significantly reduced in a number of the monitoring wells.

  6. Aquarius: Tower Rollback

    NASA Video Gallery

    The mobile service tower at NASA's Launch Complex-2 at Vandenberg Air Force Base in California is being moved away from the ULA Delta II rocket with the Aquarius/SAC-D spacecraft atop, in preparati...

  7. Preliminary Design and Evaluation of Portable Electronic Flight Progress Strips

    NASA Technical Reports Server (NTRS)

    Doble, Nathan A.; Hansman, R. John

    2002-01-01

    There has been growing interest in using electronic alternatives to the paper Flight Progress Strip (FPS) for air traffic control. However, most research has been centered on radar-based control environments, and has not considered the unique operational needs of the airport air traffic control tower. Based on an analysis of the human factors issues for control tower Decision Support Tool (DST) interfaces, a requirement has been identified for an interaction mechanism which replicates the advantages of the paper FPS (e.g., head-up operation, portability) but also enables input and output with DSTs. An approach has been developed which uses a Portable Electronic FPS that has attributes of both a paper strip and an electronic strip. The prototype flight strip system uses Personal Digital Assistants (PDAs) to replace individual paper strips in addition to a central management interface which is displayed on a desktop computer. Each PDA is connected to the management interface via a wireless local area network. The Portable Electronic FPSs replicate the core functionality of paper flight strips and have additional features which provide a heads-up interface to a DST. A departure DST is used as a motivating example. The central management interface is used for aircraft scheduling and sequencing and provides an overview of airport departure operations. This paper will present the design of the Portable Electronic FPS system as well as preliminary evaluation results.

  8. Stripping organics from groundwater and wastewater

    SciTech Connect

    Lamarre, B.; Shearouse, D.

    1996-03-01

    At thousands of installations worldwide, air stripping has been used as an efficient method for removing volatile and semi-volatile contaminants from water -- both groundwater and industrial wastewater streams. In addition to numerous field installations, extensive laboratory analysis has confirmed the performance of various types and sizes of air strippers, and has made the practice highly predictable for a wide range of contaminants. The general principles of air stripping are quite simple. Within an air stripper, an air stream is directed across a thin film of contaminated water. Contaminants at the air-water interface volatilize and are discharged to the atmosphere, or to an off-gas treatment system. The two main types of air strippers are packed towers and try-type strippers. In many cases, air stripping can be a fast, efficient and economical approach to treating organics-laden water streams. However, since different wastewater streams can vary significantly, each must be evaluated to characterize its constitutents, determine each constituent`s potential affinity or resistance to being volatilized, and identify any pre-treatment steps that need to be taken to produce the desired results.

  9. Field demonstration of in-situ air stripping using horizontal wells

    SciTech Connect

    Looney, B.B.; Kaback, D.S.

    1991-12-31

    Under sponsorship from the US Department of Energy, technical personnel from the Savannah River Laboratory and other DOE laboratories, universities and private industry have completed a full scale demonstration of environmental remediation using horizontal wells. The 139 day long test was designed to remove volatile chlorinated solvents from the subsurface using two horizontal wells. One well, approximately 90m long and 45m deep drilled below a contaminant plume in the groundwater, was used to inject air and strip the contaminants from the groundwater. A second horizontal well, approximately 50m long and 20m deep in the vadose zone, was used to extract residual contamination in the vadose zone along with the material purged from the groundwater. The test successfully removed approximately 7250 kg of contaminants. A large amount of characterization and monitoring data was collected to aid in interpretation of the test and to provide the information needed for future environmental restorations that employ directionally drilled wells as extraction or delivery systems.

  10. Field demonstration of in-situ air stripping using horizontal wells

    SciTech Connect

    Looney, B.B.; Kaback, D.S.

    1991-01-01

    Under sponsorship from the US Department of Energy, technical personnel from the Savannah River Laboratory and other DOE laboratories, universities and private industry have completed a full scale demonstration of environmental remediation using horizontal wells. The 139 day long test was designed to remove volatile chlorinated solvents from the subsurface using two horizontal wells. One well, approximately 90m long and 45m deep drilled below a contaminant plume in the groundwater, was used to inject air and strip the contaminants from the groundwater. A second horizontal well, approximately 50m long and 20m deep in the vadose zone, was used to extract residual contamination in the vadose zone along with the material purged from the groundwater. The test successfully removed approximately 7250 kg of contaminants. A large amount of characterization and monitoring data was collected to aid in interpretation of the test and to provide the information needed for future environmental restorations that employ directionally drilled wells as extraction or delivery systems.

  11. NaI(Tl) scintillator detectors stripping procedure for air kerma measurements of diagnostic X-ray beams

    NASA Astrophysics Data System (ADS)

    Oliveira, L. S. R.; Conti, C. C.; Amorim, A. S.; Balthar, M. C. V.

    2013-03-01

    Air kerma is an essential quantity for the calibration of national standards used in diagnostic radiology and the measurement of operating parameters used in radiation protection. Its measurement within the appropriate limits of accuracy, uncertainty and reproducibility is important for the characterization and control of the radiation field for the dosimetry of the patients submitted to diagnostic radiology and, also, for the assessment of the system which produces radiological images. Only the incident beam must be considered for the calculation of the air kerma. Therefore, for energy spectrum, counts apart the total energy deposition in the detector must be subtracted. It is necessary to establish a procedure to sort out the different contributions to the original spectrum and remove the counts representing scattered photons in the detector's materials, partial energy deposition due to the interactions in the detector active volume and, also, the escape peaks contributions. The main goal of this work is to present spectrum stripping procedure, using the MCNP Monte Carlo computer code, for NaI(Tl) scintillation detectors to calculate the air kerma due to an X-ray beam usually used in medical radiology. The comparison between the spectrum before stripping procedure against the reference value showed a discrepancy of more than 63%, while the comparison with the same spectrum after the stripping procedure showed a discrepancy of less than 0.2%.

  12. Nitrogen potential recovery and concentration of ammonia from swine manure using electrodialysis coupled with air stripping.

    PubMed

    Ippersiel, D; Mondor, M; Lamarche, F; Tremblay, F; Dubreuil, J; Masse, L

    2012-03-01

    The practice of intensive animal production in certain areas has resulted in excessive manure production for the available regional land base. Consequently, there is a need to develop treatment technologies to recover the valuable nutrients that manure contains so that the resulting product can be transported and used as fertilizer on agricultural land. The project presented here used electrodialysis in a dilution/concentration configuration to transfer the manure ammonia in the diluate solution by electromigration to an adjacent solution separated by an ion-exchange membrane under the driving force of an electrical potential. Then, air stripping from the electrodialysis-obtained concentrate solution without pH modification was used to isolate the ammonia in an acidic solution. An optimal process operating voltage of 17.5 V was first determined on the basis of current efficiency and total energy consumption. During the process, the swine manure pH varied from 8.5 to 8.2, values favourable for NH(4)(+) electromigration. Total ammonia nitrogen reached 21,352 mg/L in the concentrate solution, representing approximately seven times the concentration in the swine manure. Further increases in concentration were limited by water transfer from the diluate solution due to electroosmosis and osmosis. Applying vacuum to the concentrate reservoir was found to be more efficient than direct concentrate solution aeration for NH(3) recuperation in the acid trap, given that the ammonia recuperated under vacuum represented 14.5% of the theoretical value of the NH(3) present in the concentrate solution as compared to 6.2% for aeration. However, an excessively low concentrate solution pH (8.6-8.3) limited NH(3)volatilization toward the acid trap. These results suggest that the concentrate solution pH needs to be raised to promote the volatile NH(3) form of total ammonia nitrogen. PMID:21658837

  13. A scanning electron microscopy comparison of enamel polishing methods after air-rotor stripping.

    PubMed

    Piacentini, C; Sfondrini, G

    1996-01-01

    In the last few years, orthodontic literature has shown particular interest in the interproximal enamel reduction technique described as stripping or slenderizing. Most researchers have shown, by scanning electron microscopy (SEM) studies, the difficulties encountered while attempting to remove coarse abrasions left after stripping with the first instrument. The objective of this SEM study was to compare the different polishing methods proposed in the literature and to assess the efficiency of our own procedure. For this purpose, 48 healthy human teeth (premolars and molars) were used after removal for orthodontic or periodontal reasons. The teeth were divided into eight groups of six teeth each (two molars and four premolars), and mounted on a typodont to simulate a clinical situation. Each group underwent stripping according to one of the following techniques: 16-blade tungsten carbide bur and fine and ultrafine diamond burs; coarse diamond bur and fine and ultrafine diamond burs; coarse diamond disk and Sof-Lex disks (Dental products/3M, St. Paul, Minn.); 16-blade tungsten carbide bur and phosphoric acid on finishing strip; and 8-straight blade tungsten carbide diamond bur and Sof-Lex disks. The SEM investigations demonstrated that it is not possible to eliminate, with normal polishing and cleaning methods, the furrows left on the enamel both by the diamond burs and the diamond disks and the 16-blade tungsten carbide burs. Mechanical and chemical stripping as well did not prove to be effective. By contrast, with the use of a 8-straight blade tungsten carbide bur followed by Sof-Lex disks for polishing the enamel, it is possible to obtain well-polished surfaces that many times appear smoother than the intact or untreated enamel. PMID:8540483

  14. Evaluating the costs of packed-tower aeration and GAC for controlling selected organics

    SciTech Connect

    Adams, J.Q.; Clark, R.M.

    1991-01-01

    The article focuses on a preliminary cost analysis that compares liquid-phase granular activated carbon (GAC) treatment with packed-tower aeration (PTA) treatment, with and without air emissions control. The sensitivity of cost to design and operating variables is also discussed. For most of the contaminants examined, PTA appears to be more cost-effective than liquid-phase GAC, even when vapor-phase GAC is required in the stripping system.

  15. Ultrasonic extraction and field-portable anodic stripping voltammetry for the determination of lead in workplace air samples.

    PubMed

    Ashley, K; Mapp, K J; Millson, M

    1998-10-01

    An on-site, field-portable analytical method for the determination of lead in workplace air samples, based on the use of ultrasonic extraction and anodic stripping voltammetry (ASV), was evaluated. Workplace air samples were obtained using a standard method involving particulate collection onto mixed cellulose ester membrane filters. Samples were collected at work sites where airborne particulates were generated from the abrasive blasting of lead-containing paint on highway bridges. Ultrasonic extraction (UE) of air filter samples in diluted nitric acid, followed by portable ASV, was used for the determination of lead. Also, performance evaluation samples consisting of reference materials of known lead concentration were subjected to the UE-ASV procedure for lead determination. Confirmatory analyses of the air filters and performance evaluation samples subjected to the UE-ASV lead measurement method were conducted by hotplate digestion in concentrated nitric acid and 30% hydrogen peroxide, followed by inductively coupled plasma-atomic emission spectrometric (ICP-AES) determination of lead. Recoveries of lead from performance evaluation materials (when using the UE-ASV method) were found to be quantitative. The performance of the UE-ASV method for lead in air filters was found to be acceptable, as evaluated by comparison with results from hotplate strong acid digestion followed by ICP-AES analysis. Based on the results of this study, the ultrasonic extraction/portable ASV procedure demonstrates potential for the on-site determination of lead in personal breathing zone and area air samples. PMID:9794065

  16. Effect of CO{sub 2} air mixtures on the pH of air-stripped water at Treatment Facility D

    SciTech Connect

    Krauter, P.W.; Harrar, J.E.; Orloff, S.P.

    1998-01-01

    A small-scale model of the air stripping tanks at TFD was constructed and tested to determine the effect of carbon dioxide additions, to the stripper air, on system water pH. The objective was to determine whether this technique could be used to control and minimize CaCO{sub 3} scale formation. It was found that a concentration of 0.7 vol. % CO{sub 2} is required to maintain the water at its original, influent pH value of 7.4, but lower concentrations may be effective in controlling scale. There is also a possibility of reducing CO{sub 2} consumption by recycling the CO{sub 2}-rich air. The use of CO{sub 2} injection at Site 300 water treatment is reviewed.

  17. Collapsible Towers

    NASA Technical Reports Server (NTRS)

    1976-01-01

    NASA needed a means of orbiting a large radio telescope antenna. Astro Research Corporation developed a new structure that was strong, lightweight, folded into a small storage space, and could be erected by rotation. Later they adapted it to commercial use. Today the "Astromast" tower consists of tubular aluminum alloy and stainless steel members that deploy into small three-sided bays, each made rigid by six diagonal cables. All joints are flexible to permit folding and unfolding. Tower packs into container 5% of its height, can be erected without tools and is reusable. Tower has won "Design of the Year" award from Machine Design. Variations include portable emergency bridges and commercial scaffolding.

  18. Vortex-augmented cooling tower - windmill combination

    DOEpatents

    McAllister, J.E. Jr.

    1982-09-02

    A cooling tower for cooling large quantities of effluent water from a production facility by utilizing natural wind forces includes the use of a series of helically directed air inlet passages extending outwardly from the base of the tower to introduce air from any direction in a swirling vortical pattern while the force of the draft created in the tower makes it possible to place conventional power generating windmills in the air passage to provide power as a by-product.

  19. PROCESS DESIGN MANUAL FOR STRIPPING OF ORGANICS

    EPA Science Inventory

    Procedures and correlations for designing and costing stripping towers for the removal of organics from aqueous streams are presented. The emphasis is on practical methods suitable for engineering estimates. The designs cover steam strippers with and without condensers and reflux...

  20. Post-test evaluation of the geology, geochemistry, microbiology, and hydrology of the in situ air stripping demonstration site at the Savannah River Site

    SciTech Connect

    Eddy Dilek, C.A.; Looney, B.B.; Hazen, T.C.; Nichols, R.L.; Fliermans, C.B.; Parker, W.H.; Dougherty, J.M.; Kaback, D.S.; Simmons, J.L.

    1993-07-01

    A full-scale demonstration of the use of horizontal wells for in situ air stripping for environment restoration was completed as part of the Savannah River Integrated Demonstration Program. The demonstration of in situ air stripping was the first in a series of demonstrations of innovative remediation technologies for the cleanup of sites contaminated with volatile organic contaminants. The in situ air stripping system consisted of two directionally drilled wells that delivered gases to and extract contamination from the subsurface. The demonstration was designed to remediate soils and sediments in the unsaturated and saturated zones as well as groundwater contaminated with volatile organic compounds. The demonstration successfully removed significant quantities of solvent from the subsurface. The field site and horizontal wells were subsequently used for an in situ bioremediation demonstration during which methane was added to the injected air. The field conditions documented herein represent the baseline status of the site for evaluating the in situ bioremediation as well as the post-test conditions for the in situ air stripping demonstration. Characterization activities focused on documenting the nature and distribution of contamination in the subsurface. The post-test characterization activities discussed herein include results from the analysis of sediment samples, three-dimensional images of the pretest and post-test data, contaminant inventories estimated from pretest and post-test models, a detailed lithologic cross sections of the site, results of aquifer testing, and measurements of geotechnical parameters of undisturbed core sediments.

  1. Edge-state-dependent tunneling of dipole-exchange spin waves in submicrometer magnetic strips with an air gap

    NASA Astrophysics Data System (ADS)

    Xing, X. J.; Zhang, D.; Li, S. W.

    2012-12-01

    We have investigated the tunneling of dipole-exchange spin waves across an air gap in submicrometer-sized permalloy magnetic strips by means of micromagnetic simulations. The magnetizations beside the gap could form three distinct end-domain states with various strengths of dipolar coupling. Spin-wave tunneling through the gap at individual end-domain states is studied. It is found that the tunneling behavior is strongly dependent on these domain states. Nonmonotonic decay of transmission of spin waves with the increase of the gap width is observed. The underlying mechanism for these behaviors is proposed. The tunneling characteristics of the dipole-exchange spin waves differ essentially from those of the magnetostatic ones reported previously.

  2. Full scale field test of the in situ air stripping process at the Savannah River integrated demonstration test site

    SciTech Connect

    Looney, B.B.; Hazen, T.C.; Kaback, D.S.; Eddy, C.A.

    1991-06-29

    Under sponsorship from the US Department of Energy, technical personnel from the Savannah River Laboratory (SRL) and other DOE laboratories, universities and private industry have completed a full scale demonstration of environmental remediation using horizontal wells. This demonstration was performed as Phase I of an Integrated Demonstration Project designed to evaluate innovative remediation technologies for environmental restoration of sites contaminated with organic contaminants. The demonstration utilized two directionally drilled horizontal wells to deliver gases and extract contaminants from the subsurface. The resulting in situ air stripping process was designed to remediate soils and sediments above and below the water table as well as groundwater contaminated with volatile organic contaminants. The 139 day long test successfully removed volatile chlorinated solvents from the subsurface using the two horizontal wells. One well, approximately 300 ft (90m) long and 165 ft (50m) deep drilled below a contaminant plume in the groundwater, was used to inject air and strip the contaminants from the groundwater. A second horizontal well, approximately 175 ft (53m) long and 75 ft (23m) deep in the vadose zone, was used to extract residual contamination in the vadose zone along with the material purged from the groundwater. Pretest and posttest characterization data and monitoring data during the demonstration were collected to aid in interpretation of the test and to provide the information needed for future environmental restoration that employ directionally drilled wells as extraction or delivery systems. Contaminant concentration data and microbiological monitoring data are summarized in this report; the characterization data and geophysical monitoring data are documented in a series of related project reports.

  3. Characterization of dissolved organic matter in landfill leachate during the combined treatment process of air stripping, Fenton, SBR and coagulation.

    PubMed

    Liu, ZhiPing; Wu, WenHui; Shi, Ping; Guo, JinSong; Cheng, Jin

    2015-07-01

    A combined treatment process of air stripping+Fenton+sequencing batch reactor (SBR)+ coagulation was performed to remove the pollutants in landfill leachate. Molecular weight (MW) distribution and fractions of dissolved organic matter (DOM) were discussed to study the characteristics. The experiment showed that the removal rate of chemical oxygen demand (COD), five day biological oxygen demand (BOD5) and ammonia nitrogen (NH3N) by the combined process were 92.8%, 87.8% and 98.0%, respectively. Humic acid (HA) and fulvic acid (FA) were the main fractions in raw leachate with 81.8% of the total COD concentration, while hydrophilic organic matter (HyI) was the dominant fraction in the final effluent of the combined process with 63.5% of the total COD concentration. After the combined treatment process, the removal rate of DOM and fractions HA, FA, HyI were 91.9%, 97.1%, 95.8% and 71.7%, respectively. Organic matters of MW<2k and MW>100k were removed with 90.5% and 97.9% COD concentration after the treatment. The ultraviolet-visible spectra (UV-vis), Fourier transform infrared spectra (FTIR) and three-dimensional excitation-emission matrices spectra (EEMs) indicated that benzene materials and phenol compounds were preferentially removed in air stripping. High MW matters, aromatic rings, conjugated moieties and some functional groups were mainly removed by Fenton. While smallMW fractions, carboxylic acids, alcohols and protein-like materials were preferentially biodegraded via SBR. Fulvic-like and humic-like materials were mainly destroyed via Fenton oxidation and coagulation. PMID:25899801

  4. Characterization of dissolved organic matter in landfill leachate during the combined treatment process of air stripping, Fenton, SBR and coagulation

    SciTech Connect

    Liu, ZhiPing; Wu, WenHui; Shi, Ping; Guo, JinSong; Cheng, Jin

    2015-07-15

    Highlights: • DOM fractions spectra analysis during the whole treatment process. • Efficient method was achieved to remove organic matters in landfill leachate. • Molecular weight distribution and fractions were discussed. - Abstract: A combined treatment process of air stripping + Fenton + sequencing batch reactor (SBR)+ coagulation was performed to remove the pollutants in landfill leachate. Molecular weight (MW) distribution and fractions of dissolved organic matter (DOM) were discussed to study the characteristics. The experiment showed that the removal rate of chemical oxygen demand (COD), five day biological oxygen demand (BOD{sub 5}) and ammonia nitrogen (NH{sub 3}−N) by the combined process were 92.8%, 87.8% and 98.0%, respectively. Humic acid (HA) and fulvic acid (FA) were the main fractions in raw leachate with 81.8% of the total COD concentration, while hydrophilic organic matter (HyI) was the dominant fraction in the final effluent of the combined process with 63.5% of the total COD concentration. After the combined treatment process, the removal rate of DOM and fractions HA, FA, HyI were 91.9%, 97.1%, 95.8% and 71.7%, respectively. Organic matters of MW < 2 k and MW > 100 k were removed with 90.5% and 97.9% COD concentration after the treatment. The ultraviolet–visible spectra (UV–vis), Fourier transform infrared spectra (FTIR) and three-dimensional excitation-emission matrices spectra (EEMs) indicated that benzene materials and phenol compounds were preferentially removed in air stripping. High MW matters, aromatic rings, conjugated moieties and some functional groups were mainly removed by Fenton. While small MW fractions, carboxylic acids, alcohols and protein-like materials were preferentially biodegraded via SBR. Fulvic-like and humic-like materials were mainly destroyed via Fenton oxidation and coagulation.

  5. Gasifier waste water treatment: Phase I cooling tower assessment

    SciTech Connect

    Mann, M.D.; Willson, W.G.; Hendrikson, J.G.; Winton, S.L.

    1985-02-01

    Details of an advanced study of the treatability of waste waters from the fixed-bed gasification of lignite describe the test equipment and results at a pilot plant in North Dakota using stripped-gas liquor (SGL) as cooling tower makeup. Ammonia, alkalinity, phenol, and other non-hydantoin organics were removed from the cooling water by stripping and/or biological degradation, with the phenol concentration in the exhaust air exceeding the odor threshold. It will be necessary to control foaming of the circulating water, but both glycol and silicon based agents performed well during the test. It will also be necessary to reduce the high level of biofouling on heat transfer surfaces, although stainless steel fouling was not a major problem. The conclusion is that SGL is limited by potentially serious operating problems without additional treatment. 5 references, 4 figures, 7 tables.

  6. Simultaneous stripping recovery of ammonia-nitrogen and precipitation of manganese from electrolytic manganese residue by air under calcium oxide assist.

    PubMed

    Chen, Hongliang; Liu, Renlong; Shu, Jiancheng; Li, Wensheng

    2015-01-01

    Leaching tests of electrolytic manganese residue (EMR) indicated that high contents of soluble manganese and ammonia-nitrogen posed a high environmental risk. This work reports the results of simultaneous stripping recovery of ammonia-nitrogen and precipitation of manganese by air under calcium oxide assist. The ammonia-nitrogen stripping rate increased with the dosage of CaO, the air flow rate and the temperature of EMR slurry. Stripped ammonia-nitrogen was absorbed by a solution of sulfuric acid and formed soluble (NH4)2SO4 and (NH4)3H(SO4)3. The major parameters that effected soluble manganese precipitation were the dosage of added CaO and the slurry temperature. Considering these two aspects, the efficient operation conditions should be conducted with 8 wt.% added CaO, 60°C, 800 mL min(-1) air flow rate and 60-min reaction time. Under these conditions 99.99% of the soluble manganese was precipitated as Mn3O4, which was confirmed by XRD and SEM-EDS analyses. In addition, the stripping rate of ammonia-nitrogen was 99.73%. Leaching tests showed the leached toxic substances concentrations of the treated EMR met the integrated wastewater discharge standard of China (GB8978-1996). PMID:26301855

  7. Rapunzel's Tower

    ERIC Educational Resources Information Center

    Depp, Sheryl

    2007-01-01

    Children's literature often inspires the author's lessons, and reading to her primary students motivates their participation. In this article, the author presents and describes her lesson which is based on the book "Falling for Rapunzel" by Leah Wilcox. Students created a fairy tale tower in this lesson, which took place over three class periods.…

  8. Solar-Powered Air Stripping at the Rocky Flats Site, Colorado - 12361

    SciTech Connect

    Boylan, John A.

    2012-07-01

    . Initially, several alternatives such as commercial air strippers and cascade aerators were evaluated; resulting cost estimates exceeded $100,000. After several simpler alternatives were considered and prototype testing was conducted, the existing effluent metering manhole was converted to house a spray-nozzle based, solar-powered air stripper, at a cost of approximately $20,000. About two-thirds of this cost was for the solar power system, which was initially designed to only provide power for 12 hours per day. Performance data are being collected and adjustments made to optimize the design, determine maintenance requirements, and establish power needs for continuous operation. Analytical data confirm the air stripper is sharply reducing concentrations of residual contaminants. (authors)

  9. Virtual Tower

    SciTech Connect

    Wayne, R.A.

    1997-08-01

    The primary responsibility of an intrusion detection system (IDS) operator is to monitor the system, assess alarms, and summon and coordinate the response team when a threat is acknowledged. The tools currently provided to the operator are somewhat limited: monitors must be switched, keystrokes must be entered to call up intrusion sensor data, and communication with the response force must be maintained. The Virtual tower is an operator interface assembled from low-cost commercial-off-the-shelf hardware and software; it enables large amounts of data to be displayed in a virtual manner that provides instant recognition for the operator and increases assessment accuracy in alarm annunciator and control systems. This is accomplished by correlating and fusing the data into a 360-degree visual representation that employs color, auxiliary attributes, video, and directional audio to prompt the operator. The Virtual Tower would be a valuable low-cost enhancement to existing systems.

  10. Static voltage distribution between turns of secondary winding of air-core spiral strip transformer and its application

    NASA Astrophysics Data System (ADS)

    Zhang, Hong-bo; Liu, Jin-liang; Cheng, Xin-bing; Zhang, Yu

    2011-09-01

    The static voltage distribution between winding turns has great impact on output characteristics and lifetime of the air-core spiral strip pulse transformer (ACSSPT). In this paper, winding inductance was calculated by electromagnetic theory, so that the static voltage distribution between turns of secondary winding of ACSSPT was analyzed conveniently. According to theoretical analysis, a voltage gradient because of the turn-to-turn capacitance was clearly noticeable across the ground turns. Simulation results of Pspice and CST EM Studio codes showed that the voltage distribution between turns of secondary winding had linear increments from the output turn to the ground turn. In experiment, the difference in increased voltage between the ground turns and the output turns of a 20-turns secondary winding is almost 50%, which is believed to be responsible for premature breakdown of the insulation, particularly between the ground turns. The experimental results demonstrated the theoretical analysis and simulation results, which had important value for stable and long lifetime ACSSPT design. A new ACSSPT with improved structure has been used successfully in intense electron beam accelerators steadily.

  11. 2004 Savannah River Cooling Tower Collection (U)

    SciTech Connect

    Garrett, Alfred; Parker, Matthew J.; Villa-Aleman, E.

    2005-05-01

    The Savannah River National Laboratory (SRNL) collected ground truth in and around the Savannah River Site (SRS) F-Area cooling tower during the spring and summer of 2004. The ground truth data consisted of air temperatures and humidity inside and around the cooling tower, wind speed and direction, cooling water temperatures entering; inside adn leaving the cooling tower, cooling tower fan exhaust velocities and thermal images taken from helicopters. The F-Area cooling tower had six cells, some of which were operated with fans off during long periods of the collection. The operating status (fan on or off) for each of the six cells was derived from operations logbooks and added to the collection database. SRNL collected the F-Area cooling tower data to produce a database suitable for validation of a cooling tower model used by one of SRNL's customer agencies. SRNL considers the data to be accurate enough for use in a model validation effort. Also, the thermal images of the cooling tower decks and throats combined with the temperature measurements inside the tower provide valuable information about the appearance of cooling towers as a function of fan operating status and time of day.

  12. Pilot-scale treatment of gasification wastewater and reuse in a cooling tower

    SciTech Connect

    Willson, W.G.; Mayer, G.G.; Hendrikson, J.G.; Winton, S.L.

    1985-04-01

    The University of North Dakota Energy Research Center has operated a 910 kg/hr, oxygen-blown fixed-bed gasifier to produce lignite-derived effluents for characterization, treatment, and reuse studies. Reuse of waste water in a cooling tower was investigated to define environmental and process effects as a function of pretreatment. The gasification wastewater was pretreated in pilot wastewater treatement units which simulate available technology. During the first phase of the program, wastewater was pretreated by solvent extraction and steam stripping to produce phenol and ammonia concentrations comparable to those expected at the Great Plains Gasification Associates plant. This pretreated wastewater was concentrated in a cooling tower to 10 cycles of concentration. No biocides or corrosion inhibitors were added. Severe fouling of heat exchange surfaces and high corrosion rates of carbon steel were encountered. Over 90% of the phenol entering the cooling tower was found to be stripped into the cooling tower exhaust air stream. The high levels of organics remaining in this minimally treated wastewater suggested that further biological treatment and possibly polishing by carbon adsorption would be necessary to prepare a satisfactory feed. In the second phase of the program, the SGL was further treated in an activated sludge process followed by granular activated carbon adsorption. Biotreatment removed 96% of the BOD with a three-day retention time while obtaining satisfactory sludge settling rates in spite of varied influent concentrations. Biorefractory materials were adsorbed on GAC to reach an effuent COD level of 150 mg/l. This upgrading was sufficient to reduce organic emissions from the cooling tower, but corrosion rates were higher than in the previous test, again showing the necessity for corrosion inhibitors. 8 figs., 3 tabs.

  13. An Air-Stripping Packed Bed Combined with a Biofilm-Type Biological Process for Treating BTEX and Total Petroleum Hydrocarbon Contaminated Groudwater

    NASA Astrophysics Data System (ADS)

    Hong, U.; Park, S.; Lim, J.; Lee, W.; Kwon, S.; Kim, Y.

    2009-12-01

    In this study, we examined the removal efficiency of a volatile compound (e.g. toluene) and a less volatile compound [e.g. total petroleum hydrocarbon (TPH)] using an air stripping packed bed combined with a biofilm-type biological process. We hypothesized that this system might be effective and economical to simultaneously remove both volatile and less volatile compounds. The gas-tight reactor has 5.9-inch-diameter and 48.8-inch-height. A spray nozzle was installed at the top cover to distribute the liquid evenly through reactor. The reactor was filled with polypropylene packing media for the increase of volatilization surface area and the growth of TPH degrading facultative aerobic bacteria on the surface of the packing media. In air stripping experiments, 45.6%, 71.7%, 72.0%, and 75.4% of toluene was removed at air injection rates of 0 L/min, 2.5 L/min, 4 L/min, and 6 L/min, respectively. Through the result, we confirmed that toluene removal efficiency increased by injecting higher amounts of air. TPH removal by stripping was minimal. To remove a less volatile TPH by commercial TPH degrading culture (BIO-ZYME B-52), 15-times diluted culture was circulated through the reactor for 2-3 days to build up a biofilm on the surface of packing media with 1 mg-soluble nitrogen source /L-water per 1 ppm of TPH. Experiments evaluating the degree of TPH biodegradation in this system are carrying out.

  14. Modification of pure oxygen absorption equipment for concurrent stripping of carbon dioxide

    USGS Publications Warehouse

    Watten, B.J.; Sibrell, P.L.; Montgomery, G.A.; Tsukuda, S.M.

    2004-01-01

    The high solubility of carbon dioxide precludes significant desorption within commercial oxygen absorption equipment. This operating characteristic of the equipment limits its application in recirculating water culture systems despite its ability to significantly increase allowable fish loading rates (kg/(L min)). Carbon dioxide (DC) is typically removed by air stripping. This process requires a significant energy input for forced air movement, air heating in cold climates and water pumping. We developed a modification for a spray tower that provides for carbon dioxide desorption as well as oxygen absorption. Elimination of the air-stripping step reduces pumping costs while allowing dissolved nitrogen to drop below saturation concentrations. This latter response provides for an improvement in oxygen absorption efficiency within the spray tower. DC desorption is achieved by directing head-space gases from the spray tower (O2, N2, CO2) through a sealed packed tower scrubber receiving a 2 N NaOH solution. Carbon dioxide is selectively removed from the gas stream, by chemical reaction, forming the product Na 2CO3. Scrubber off-gas, lean with regard to carbon dioxide but still rich with oxygen, is redirected through the spray tower for further stripping of DC and absorption of oxygen. Make-up NaOH is metered into the scrubbing solution sump on an as needed basis as directed by a feedback control loop programmed to maintain a scrubbing solution pH of 11.4-11.8. The spent NaOH solution is collected, then regenerated for reuse, in a batch process that requires relatively inexpensive hydrated lime (Ca(OH)2). A by-product of the regeneration step is an alkaline filter cake, which may have use in bio-solids stabilization. Given the enhanced gas transfer rates possible with chemical reaction, the required NaOH solution flow rate through the scrubber represents a fraction of the spray tower water flow rate. Further, isolation of the water being treated from the atmosphere (1

  15. Performance specification for control tower display systems

    NASA Astrophysics Data System (ADS)

    Aleva, Denise L.; Meyer, Frederick M.

    2003-09-01

    Personnel in airport control towers monitor and direct the takeoff of outgoing aircraft, landing of incoming aircraft and all movements of aircraft on the ground. Although the primary source of information for the Local Controller, Assistant Local Controller and the Ground Controller is the real world viewed through the windows of the control tower, electronic displays are also used to provide situation awareness. Due to the criticality of the work to be performed by the controllers and the rather unique environment of the air traffic control tower, display hardware standards, which have been developed for general use, are not directly applicable. The Federal Aviation Administration (FAA) requested assistance of Air Force Research Laboratory Human Effectiveness Directorate in producing a document which can be adopted as a Tower Display Standard usable by display engineers, human factors practitioners and system integrators. Particular emphasis was placed on human factors issues applicable to the control tower environment and controller task demands.

  16. CATALYTIC OXIDATION OF GROUNDWATER STRIPPING EMISSIONS

    EPA Science Inventory

    The paper reviews the applicability of catalytic oxidation to control ground-water air stripping gaseous effluents, with special attention to system designs and case histories. The variety of contaminants and catalyst poisons encountered in stripping operations are also reviewed....

  17. Long-term measurements of aerosols and carbon monoxide at the ZOTTO tall tower to characterize polluted and pristine air in the Siberian Taiga

    NASA Astrophysics Data System (ADS)

    Chi, X.; Winderlich, J.; Mayer, J.-C.; Panov, A. V.; Heimann, M.; Birmili, W.; Heintzenberg, J.; Cheng, Y.; Andreae, M. O.

    2013-07-01

    Siberia is one of few background regions in the Northern Hemisphere where the atmosphere may sometimes approach pristine conditions. We present the time series of aerosol and carbon monoxide (CO) measurements between September~2006 and December 2010 at the Zotino Tall Tower Observatory (ZOTTO) in Central Siberia (61° N; 90° E). We investigate the seasonal, weekly and diurnal variations of aerosol properties (including absorption and scattering coefficients and derived parameters, like equivalent black carbon (BCe), Ångström exponent, single scattering albedo, and backscattering ratio) and the CO mixing ratios. Criteria were established to distinguish polluted and near-pristine air masses and characterize them separately. Depending on the season, 15-47% of the sampling time at ZOTTO was representative of a clean atmosphere. The summer pristine data indicates that primary biogenic and/or secondary organic aerosol formation are quite strong particle sources in the Siberian Taiga. The summer seasons 2007-2008 are dominated by an Aitken mode of 80 nm size, whereas the summer 2009 with prevailing easterly winds produced aerosols in the accumulation mode around 200 nm size. We found these differences mainly related to air temperature, in parallel with production rates of biogenic volatile organic compounds (VOC). In winter, the footprint and aerosol size distribution (with a peak at 160 nm) of the clean background air are characteristic for aged aerosols from anthropogenic sources at great distances from ZOTTO and diluted biofuel burning emissions from heating. The wintertime polluted air originates from the large cities to the south and southwest of the site; these aerosols have a dominant mode around 100 nm, and the Δ BCe/Δ CO ratio of 7-11 ng m-3 ppb-1 suggests dominant contributions from coal and biofuel burning for heating. During summer, anthropogenic emissions are the dominant contributor to the pollution aerosols at ZOTTO, while only 12% of the polluted

  18. Long-term measurements of aerosol and carbon monoxide at the ZOTTO tall tower to characterize polluted and pristine air in the Siberian taiga

    NASA Astrophysics Data System (ADS)

    Chi, X.; Winderlich, J.; Mayer, J.-C.; Panov, A. V.; Heimann, M.; Birmili, W.; Heintzenberg, J.; Cheng, Y.; Andreae, M. O.

    2013-12-01

    Siberia is one of few continental regions in the Northern Hemisphere where the atmosphere may sometimes approach pristine background conditions. We present the time series of aerosol and carbon monoxide (CO) measurements between September 2006 and December 2011 at the Zotino Tall Tower Observatory (ZOTTO) in Central Siberia (61° N; 89° E). We investigate the seasonal, weekly and diurnal variations of aerosol properties (including absorption and scattering coefficients and derived parameters, such as equivalent black carbon (BCe), Ångström exponent, single scattering albedo, and backscattering ratio) and the CO mixing ratios. Criteria were established to distinguish polluted from near-pristine air masses, providing quantitative characteristics for each type. Depending on the season, 23-36% of the sampling time at ZOTTO was found to be representative of a clean atmosphere. The summer pristine data indicate that primary biogenic and secondary organic aerosol formation are quite strong particle sources in the Siberian taiga. The summer seasons 2007-2008 were dominated by an Aitken mode around 80 nm size, whereas the summer 2009 with prevailing easterly winds produced particles in the accumulation mode around 200 nm size. We found these differences to be mainly related to air temperature, through its effect on the production rates of biogenic volatile organic compounds (VOC) precursor gases. In winter, the particle size distribution peaked at 160 nm, and the footprint of clean background air was characteristic for aged particles from anthropogenic sources at great distances from ZOTTO and diluted biofuel burning emissions from domestic heating. The wintertime polluted air originates mainly from large cities south and southwest of the site; these particles have a dominant mode around 100 nm, and the ΔBCe / ΔCO ratio of 7-11 ng m-3 ppb-1 suggests dominant contributions from coal and biofuel burning for heating. During summer, anthropogenic emissions are the dominant

  19. Drop tower with no aerodynamic drag

    NASA Technical Reports Server (NTRS)

    Kendall, J. M., Jr.

    1981-01-01

    Cooling air accelerated to match velocity of falling object eliminates drag. 3 meter drop tower with suction fan and specific geometry causes air to accelerate downward at 1 g. Although cooling of molten material released from top is slow because surrounding air moves with it, drop remains nearly spherical.

  20. Characterization of the geology, geochemistry, hydrology and microbiology of the in-situ air stripping demonstration site at the Savannah River Site

    SciTech Connect

    Eddy, C.A.; Looney, B.B.; Dougherty, J.M.; Hazen, T.C.; Kaback, D.S.

    1991-05-01

    The Savannah River Site is the location of an Integrated Demonstration Project designed to evaluate innovative remediation technologies for environmental restoration at sites contaminated with volatile organic contaminants. This demonstration utilizes directionally drilled horizontal wells to deliver gases and extract contaminants from the subsurface. Phase I of the Integrated Demonstration focused on the application and development of in-situ air stripping technologies to remediate soils and sediments above and below the water table as well as groundwater contaminated with volatile organic contaminants. The objective of this report is to provide baseline information on the geology, geochemistry, hydrology, and microbiology of the demonstration site prior to the test. The distribution of contaminants in soils and sediments in the saturated zone and groundwater is emphasized. These data will be combined with data collected after the demonstration in order to evaluate the effectiveness of in-situ air stripping. New technologies for environmental characterization that were evaluated include depth discrete groundwater sampling (HydroPunch) and three-dimensional modeling of contaminant data.

  1. Removal of organic pollutants from 2,2',5,5'-tetrachlorobenzidine (TCB) industrial wastewater by micro-electrochemical oxidation and air-stripping.

    PubMed

    Shibin, Xia; Shuichun, Xia; Changqing, Zhu

    2007-06-01

    A feasible method for treatment of the wastewater from the two-staged neutralization in 2,2',5,5'-tetrachlorobenzidine (TCB) manufacturing processes, a refractory dye intermediate effluents, based on combined micro-electrochemical oxidation or iron-chipping filtration (ICF) and air-stripping reactor (ASR), was developed. On conditions of HRT 1h, pH 3.0 in ICF and HRT 38 h, gas-liquid ratio 15, pH 6.0-8.65, temperature 26 degrees C in ASR, the overall COD, color, TCB and NH(4)(+)-N removal were 96.8%, 91%, 87.61% and 62%, respectively, during the treatment of TCB wastewater from the two-staged neutralization dissolved by methanol. The averaged 18.3%, 81.7% of the total degraded COD, 35.2%, 64.8% of TCB were carried out in ICF and ASR, respectively. NH(4)(+)-N removal was finished mainly in ASR. The experimental results indicated that the combined micro-electrochemical oxidation and air-stripping process performed good treatment of COD, color, TCB and NH(4)(+)-N removal in TCB wastewater from the two-staged neutralization dissolved by ethanol or acetone, came up the discharge standard in China. But the TCB wastewater from the two-staged neutralization dissolved by methanol should be deeply treated before discharged. PMID:17118553

  2. Status of in-situ air stripping tests and proposed modifications: Horizontal wells AMH-1 and AMH-2 Savannah River Site

    SciTech Connect

    Kaback, D.S.; Looney, B.B.

    1989-08-01

    A project to drill and install two horizontal vapor extraction/air injection wells at the Savannah River Site (SRS), Aiken, South Carolina, was performed in September and October of 1988. The project was performed to test the feasibility of horizontal drilling technologies in shallow unconsolidated sediments. Additional study to evaluate the effectiveness of in-situ air stripping of volatile organics from the ground water and unsaturated soils is planned. This status report contains (1) a short summary of the construction details of the two horizontal wells and (2) proposed modifications to the original program plan (Kaback and Looney 1988; Looney and Kaback, 1988). The modifications include added pressure monitoring and use of an inert tracer gas (helium) to better evaluate system performance. This paper contains sections that provide information requested by the South Carolina Department Health and Environmental Control as part of the underground injection well permitting process. 3 refs., 6 figs.

  3. Cellular Phone Towers

    MedlinePlus

    ... the call. How are people exposed to the energy from cellular phone towers? As people use cell ... where people can be exposed to them. The energy from a cellular phone tower antenna, like that ...

  4. Simultaneous removal of ammonia, P and COD from anaerobically digested piggery wastewater using an integrated process of chemical precipitation and air stripping.

    PubMed

    Quan, Xuejun; Ye, Changying; Xiong, Yanqi; Xiang, Jinxin; Wang, Fuping

    2010-06-15

    The paper presented an efficient integrated physicochemical process, which consists of chemical precipitation and air stripping, for the simultaneous removal of NH(3)-N, total P and COD from anaerobically digested piggery wastewater. In the integrated process, Ca(OH) (2) was used as the precipitant for NH(4)(+), PO(4)(3-) and organic phosphorous compounds, and as the pH adjuster for the air stripping of residual ammonia. The possibility of the suggested process and the related mechanisms were first investigated through a series of equilibrium tests. Laboratory scale tests were carried out to validate the application possibility of the integrated process using a new-patented water sparged aerocyclone reactor (WSA). The WSA could be effectively used for the simultaneous removal of NH(3)-N, total P and COD. 3g/L of Ca(OH) (2) is a proper dosage for the simultaneous removal. The simultaneous removal of NH(3)-N, total P and COD in the WSA reactor could be easily optimized by selecting a proper air inlet velocity and a proper jet velocity of the liquid phase. In all the cases, the removal efficiencies of the NH(3)-N, total P and COD were over 91%, 99.2% and 52% for NH(3)-N, total P and COD, respectively. The formed precipitates in the process could be easily settled down from the suspension system. Therefore, the integrated process provided an efficient alternative for the simultaneous removal of NH(3)-N, total P and COD from the wastewater. PMID:20189301

  5. Surface and Tower Meteorological Instrumentation at NSA Handbook - January 2006

    SciTech Connect

    MT Ritsche

    2006-01-30

    The Surface and Tower Meteorological Instrumentation at Atqasuk (METTWR2H) uses mainly conventional in situ sensors to measure wind speed, wind direction, air temperature, dew point and humidity mounted on a 10-m tower. It also obtains barometric pressure, visibility, and precipitation data from sensors at or near the base of the tower. In addition, a Chilled Mirror Hygrometer is located at 1 m for comparison purposes. Temperature and relative humidity probes are mounted at 2 m and 5 m on the tower. For more information, see the Surface and Tower Meteorological Instrumentation at Atqasuk Handbook.

  6. Radon data acquisition: An automated system for radon analysis of both ground air and tower air and for the simultaneous logging of meteorological data

    SciTech Connect

    Martins, S.

    1990-10-01

    A system to acquire radon data was developed at Lawrence Livermore National Laboratory (LLNL) to provide information about the effect of weather conditions on the release of radon gas from soils into air. One of the system criteria that drive other design considerations was the need for operation at remote sites where the availability of 120-volt AC power was problematic. As a consequence, all components were selected or designed to run on +12 and/or {minus}12 volts DC. PC-based laptop computers were used for all data acquisition because of their availability, their low power consumption, and the abundance of software written for this platform. The system is comprised of four major sub-systems that are linked by laptop computers: radon-monitor controller, HANDAR 540 data-capture platform, radon-detection units, and barometric pressure unit. Using this system, we successfully collected data at an LLNL field site during 1990. Data from meteorological sensors and radon-concentration profiles from both air and soil were acquired simultaneously and logged on MS-DOS computers for data reduction at a future time. This document describes the functions, hardware, firmware, and software of this system.

  7. 4. SOUTHWEST CORNER OF METEOROLOGICAL TOWER; SOUTH FACE OF SLC3W ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. SOUTHWEST CORNER OF METEOROLOGICAL TOWER; SOUTH FACE OF SLC-3W MST IN BACKGROUND - Vandenberg Air Force Base, Space Launch Complex 3, Meteorological Shed & Tower, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. Stripping Voltammetry

    NASA Astrophysics Data System (ADS)

    Lovrić, Milivoj

    Electrochemical stripping means the oxidative or reductive removal of atoms, ions, or compounds from an electrode surface (or from the electrode body, as in the case of liquid mercury electrodes with dissolved metals) [1-5]. In general, these atoms, ions, or compounds have been preliminarily immobilized on the surface of an inert electrode (or within it) as the result of a preconcentration step, while the products of the electrochemical stripping will dissolve in the electrolytic solution. Often the product of the electrochemical stripping is identical to the analyte before the preconcentration. However, there are exemptions to these rules. Electroanalytical stripping methods comprise two steps: first, the accumulation of a dissolved analyte onto, or in, the working electrode, and, second, the subsequent stripping of the accumulated substance by a voltammetric [3, 5], potentiometric [6, 7], or coulometric [8] technique. In stripping voltammetry, the condition is that there are two independent linear relationships: the first one between the activity of accumulated substance and the concentration of analyte in the sample, and the second between the maximum stripping current and the accumulated substance activity. Hence, a cumulative linear relationship between the maximum response and the analyte concentration exists. However, the electrode capacity for the analyte accumulation is limited and the condition of linearity is satisfied only well below the electrode saturation. For this reason, stripping voltammetry is used mainly in trace analysis. The limit of detection depends on the factor of proportionality between the activity of the accumulated substance and the bulk concentration of the analyte. This factor is a constant in the case of a chemical accumulation, but for electrochemical accumulation it depends on the electrode potential. The factor of proportionality between the maximum stripping current and the analyte concentration is rarely known exactly. In fact

  9. Integration of photocatalytic oxidation with air stripping of contaminated aquifers. Report for 1 October 1993--30 June 1997

    SciTech Connect

    Changrani, R.; Raupp, G.B.; Turchi, C.

    1998-12-01

    The global objective of this work was to evaluate the integration of gas-solid ultraviolet (UV) photocatalytic oxidation (PCO) downstream of an air stripper as a technology for cost-effectively treating water pumped from an aquifer contaminated with chlorinated volatile organic compounds (VOCs). Experimental work was performed at the bench-scale in the laboratory during the first phase of the project, and at the pilot-scale in a simulated field-test situation during the second phase.

  10. 43. TOP OF SOUTHEAST TOWER FROM SOUTH TOWER ROOF, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. TOP OF SOUTHEAST TOWER FROM SOUTH TOWER ROOF, LOOKING EAST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  11. 37. NORTH TOWER UPPER ZONE FROM SOUTH TOWER ROOF, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. NORTH TOWER UPPER ZONE FROM SOUTH TOWER ROOF, LOOKING NORTH - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  12. 19. NORTH TOWER, PORTE COCHERE & FLAG TOWER, LOOKING SOUTHWEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. NORTH TOWER, PORTE COCHERE & FLAG TOWER, LOOKING SOUTHWEST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  13. 47. NORTHWEST TOWER FROM SOUTH TOWER ROOF, LOOKING NORTH BY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. NORTHWEST TOWER FROM SOUTH TOWER ROOF, LOOKING NORTH BY NORTHWEST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  14. 36. FLAG TOWER CLOCK ZONE FROM SOUTH TOWER ROOF, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. FLAG TOWER CLOCK ZONE FROM SOUTH TOWER ROOF, LOOKING NORTH - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  15. 40. CAMPANILE & SOUTHEAST TOWER FROM SOUTH TOWER ROOF, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    40. CAMPANILE & SOUTHEAST TOWER FROM SOUTH TOWER ROOF, LOOKING EAST BY NORTHEAST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  16. 18. NORTH TOWER, PORTE COCHERE & FLAG TOWER, LOOKING SOUTHWEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. NORTH TOWER, PORTE COCHERE & FLAG TOWER, LOOKING SOUTHWEST BY WEST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  17. PERFORMANCE ANALYSIS OF MECHANICAL DRAFT COOLING TOWER

    SciTech Connect

    Lee, S; Alfred Garrett, A; James02 Bollinger, J; Larry Koffman, L

    2009-02-10

    Industrial processes use mechanical draft cooling towers (MDCT's) to dissipate waste heat by transferring heat from water to air via evaporative cooling, which causes air humidification. The Savannah River Site (SRS) has cross-flow and counter-current MDCT's consisting of four independent compartments called cells. Each cell has its own fan to help maximize heat transfer between ambient air and circulated water. The primary objective of the work is to simulate the cooling tower performance for the counter-current cooling tower and to conduct a parametric study under different fan speeds and ambient air conditions. The Savannah River National Laboratory (SRNL) developed a computational fluid dynamics (CFD) model and performed the benchmarking analysis against the integral measurement results to accomplish the objective. The model uses three-dimensional steady-state momentum, continuity equations, air-vapor species balance equation, and two-equation turbulence as the basic governing equations. It was assumed that vapor phase is always transported by the continuous air phase with no slip velocity. In this case, water droplet component was considered as discrete phase for the interfacial heat and mass transfer via Lagrangian approach. Thus, the air-vapor mixture model with discrete water droplet phase is used for the analysis. A series of parametric calculations was performed to investigate the impact of wind speeds and ambient conditions on the thermal performance of the cooling tower when fans were operating and when they were turned off. The model was also benchmarked against the literature data and the SRS integral test results for key parameters such as air temperature and humidity at the tower exit and water temperature for given ambient conditions. Detailed results will be published here.

  18. Drop Tower Physics

    ERIC Educational Resources Information Center

    Dittrich, William A.

    2014-01-01

    The drop towers of yesteryear were used to make lead shot for muskets, as described in "The Physics Teacher" in April 2012. However, modern drop towers are essentially elevators designed so that the cable can "break" on demand, creating an environment with microgravity for a short period of time, currently up to nine seconds at…

  19. Confusion at the Tower

    ERIC Educational Resources Information Center

    Li, Loretta F.

    2014-01-01

    This study will explore the omission of the Tower of Babel narrative from middle and secondary school world history, world studies, and world geography textbooks and will consider what might be learned from inclusion of the story in the curriculum. A total of 17 textbooks are analyzed. The Tower of Babel narrative is examined within the context of…

  20. Measurement and characterization of emissions from a gas liquor fed cooling tower

    NASA Astrophysics Data System (ADS)

    Galegher, Sheila J.; Mann, Michael D.

    Phase I cooling tower testing at the University of North Dakota Energy Research Center (UNDERC) was designed to use solvent extracted and steam stripped wastewater from fixed-bed gasification of lignite as makeup. The objective of this test was to simulate the proposed mode of operation at the Great Plains Gasification Associates (GPGA) plant. A crucial part of this study was the characterization of emissions from a stripped gas liquor (SGL) fed cooling tower. Several types of sampling equipment including a multicyclone, cooled impingers, and an XAD resin trap were used for the collection and retention of components in the tower evaporate. Results of this study indicated that a significant portion of the phenol and ammonia, and also some methanol, in the tower makeup stream were stripped into the atmosphere. Concentration levels of 26,900 μg m -3 ammonia, 8000 μg m -3 phenol and 2500 μ m -3 methanol were detected in the lower exhaust.

  1. Wind tower service lift

    DOEpatents

    Oliphant, David; Quilter, Jared; Andersen, Todd; Conroy, Thomas

    2011-09-13

    An apparatus used for maintaining a wind tower structure wherein the wind tower structure may have a plurality of legs and may be configured to support a wind turbine above the ground in a better position to interface with winds. The lift structure may be configured for carrying objects and have a guide system and drive system for mechanically communicating with a primary cable, rail or other first elongate member attached to the wind tower structure. The drive system and guide system may transmit forces that move the lift relative to the cable and thereby relative to the wind tower structure. A control interface may be included for controlling the amount and direction of the power into the guide system and drive system thereby causing the guide system and drive system to move the lift relative to said first elongate member such that said lift moves relative to said wind tower structure.

  2. NORTH FRONT AND WEST SIDE, HIGH ENCLOSED METAL OBSERVATION TOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NORTH FRONT AND WEST SIDE, HIGH ENCLOSED METAL OBSERVATION TOWER LOCATED APPROXIMATELY 1800 FEET SOUTH OF TRACK. Looking southeast - Edwards Air Force Base, South Base Sled Track, Observation Tower, South of west end of Sled Track, Lancaster, Los Angeles County, CA

  3. 8. SOUTH SIDE OF EAST PHOTO TOWER; ELECTRICAL POWER BOX ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. SOUTH SIDE OF EAST PHOTO TOWER; ELECTRICAL POWER BOX ON RIGHT. LEFT TO RIGHT IN BACKGROUND: A STORAGE SHED (BLDG. 776), METEOROLOGICAL TOWER, PYROTECHNIC SHED (BLDG. 757), AND SLC-3W MST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  4. Within compound, from Guard Tower (Building 5762), looking southwest, Technical ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Within compound, from Guard Tower (Building 5762), looking southwest, Technical Equipment Building (Building 5760) to left, Microwave Tower (associated with Building 5769) and Civil Engineering Storage Building (Building 5766) to left - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  5. 7. SOUTHWEST CORNER OF EAST PHOTO TOWER. CLOSED WINDOW ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. SOUTHWEST CORNER OF EAST PHOTO TOWER. CLOSED WINDOW ON WEST SIDE; ELECTRICAL POWER BOX ON EAST SIDE OF PHOTO TOWER. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. Robotic Stripping

    NASA Technical Reports Server (NTRS)

    2000-01-01

    UltraStrip Systems, Inc.'s M-200 removes paint from the hulls of ships faster than traditional grit-blasting methods. And, it does so without producing toxic airborne particles common to traditional methods. The M-2000 magnetically attaches itself to the hull of the ship. Its water jets generate 40,000 pounds of pressure per square inch, blasting away paint down to the ships steel substrate. The only by product is water and dried paint chips and these are captured by a vacuum system so no toxic residue can escape. It was built out of a partnership between the Jet Propulsion Laboratory and the National Robotics Engineering Consortium.

  7. Drop Tower Physics

    NASA Astrophysics Data System (ADS)

    Dittrich, William A. Toby

    2014-10-01

    The drop towers of yesteryear were used to make lead shot for muskets, as described in The Physics Teacher1 in April 2012. However, modern drop towers are essentially elevators designed so that the cable can "break" on demand, creating an environment with microgravity for a short period of time, currently up to nine seconds at the drop tower in Bremen, Germany. Using these drop towers, one can briefly investigate various physical systems operating in this near zero-g environment. The resulting "Drop Tower Physics" is a new and exciting way to challenge students with a physical example that requires solid knowledge of many basic physics principles, and it forces them to practice the scientific method. The question is, "How would a simple toy, like a pendulum, behave when it is suddenly exposed to a zero-g environment?" The student must then postulate a particular behavior, test the hypothesis against physical principles, and if the hypothesis conforms to these chosen physical laws, the student can formulate a final conclusion. At that point having access to a drop tower is very convenient, in that the student can then experimentally test his or her conclusion. The purpose of this discussion is to explain the response of these physical systems ("toys") when the transition is made to a zero-g environment and to provide video demonstrations of this behavior to support in-class discussions of Drop Tower Physics.

  8. Extensible Wind Towers

    NASA Astrophysics Data System (ADS)

    Sinagra, Marco; Tucciarelli, Tullio

    The diffusion of wind energy generators is restricted by their strong landscape impact. The PERIMA project is about the development of an extensible wind tower able to support a wind machine for several hundred kW at its optimal working height, up to more than 50 m. The wind tower has a telescopic structure, made by several tubes located inside each other with their axis in vertical direction. The lifting force is given by a jack-up system confined inside a shaft, drilled below the ground level. In the retracted tower configuration, at rest, tower tubes are hidden in the foundation of the telescopic structure, located below the ground surface, and the wind machine is the only emerging part of the system. The lifting system is based on a couple of oleodynamic cylinders that jack-up a central tube connected to the top of the tower by a spring, with a diameter smaller than the minimum tower diameter and with a length a bit greater than the length of the extended telescopic structure. The central tube works as plunger and lifts all telescopic elements. The constraint between the telescopic elements is ensured by special parts, which are kept in traction by the force of the spring and provide the resisting moment. The most evident benefit of the proposed system is attained with the use of a two-blade propeller, which can be kept horizontal in the retracted tower configuration.

  9. 14 CFR 170.13 - Airport Traffic Control Tower (ATCT) establishment criteria.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Airport Traffic Control Tower (ATCT... AIR TRAFFIC CONTROL SERVICES AND NAVIGATIONAL FACILITIES Airport Traffic Control Towers § 170.13 Airport Traffic Control Tower (ATCT) establishment criteria. (a) The following criteria along with...

  10. 14 CFR 170.13 - Airport Traffic Control Tower (ATCT) establishment criteria.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Airport Traffic Control Tower (ATCT... AIR TRAFFIC CONTROL SERVICES AND NAVIGATIONAL FACILITIES Airport Traffic Control Towers § 170.13 Airport Traffic Control Tower (ATCT) establishment criteria. (a) The following criteria along with...

  11. 14 CFR 170.13 - Airport Traffic Control Tower (ATCT) establishment criteria.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Airport Traffic Control Tower (ATCT... AIR TRAFFIC CONTROL SERVICES AND NAVIGATIONAL FACILITIES Airport Traffic Control Towers § 170.13 Airport Traffic Control Tower (ATCT) establishment criteria. (a) The following criteria along with...

  12. Tower Camera Handbook

    SciTech Connect

    Moudry, D

    2005-01-01

    The tower camera in Barrow provides hourly images of ground surrounding the tower. These images may be used to determine fractional snow cover as winter arrives, for comparison with the albedo that can be calculated from downward-looking radiometers, as well as some indication of present weather. Similarly, during spring time, the camera images show the changes in the ground albedo as the snow melts. The tower images are saved in hourly intervals. In addition, two other cameras, the skydeck camera in Barrow and the piling camera in Atqasuk, show the current conditions at those sites.

  13. Combined air stripper/membrane vapor separation systems. Final report

    SciTech Connect

    Wijmans, J.G.; Baker, R.W.; Kamaruddin, H.D.; Kaschemekat, J.; Olsen, R.P.; Rose, M.E.; Segelke, S.V.

    1992-11-01

    Air stripping is an economical and efficient method of removing dissolved volatile organic compounds (VOCs) from contaminated groundwater. Air strippers, however, produce a vent air stream, which must meet the local air quality limits. If the VOC content exceeds the limits, direct discharge is not possible; therefore, a carbon adsorption VOC capture system is used to treat the vent air. This treatment step adds a cost of at least $50/lb of VOC captured. In this program, a combined air stripper/membrane vapor separation system was constructed and demonstrated in the laboratory. The membrane system captures VOCs from the stripper vent stream at a projected cost of $15/lb VOC for a water VOC content of 5 ppmw, and $75/lb VOC for a water VOC content of 1 ppmw. The VOCs are recovered as a small, concentrated liquid fraction for disposal or solvent recycling. The concept has been demonstrated in experiments with a system capable of handling up to 150,000 gpd of water. The existing demonstration system is available for field tests at a DOE facility or remediation site. Replacement of the current short air stripping tower (effective height 3 m) with a taller tower is recommended to improve VOC removal.

  14. DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER SIX WITH TOWERS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER SIX WITH TOWERS SEVEN,EIGHT, NINE, TEN, AND BREAK OVER TOWER IN DISTANCE, LOOKING NORTH. TOWER SIX IS THE LAST BEFORE A DEEP CHASM, AS IS SEEN BY THE DISTANCE BETWEEN TOWERS SIX AND SEVEN. SEE CA-291-48 (CT) FOR IDENTICAL COLOR TRANSPARENCY. - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA

  15. DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER SIX WITH TOWERS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER SIX WITH TOWERS SEVEN, EIGHT, NINE, TEN, AND BREAK OVER TOWER IN DISTANCE, LOOKING NORTH. TOWER SIX IS THE LAST BEFORE A DEEP CHASM, AS IS SEEN BY THE DISTANCE BETWEEN TOWERS SIX AND SEVEN. SEE CA-291-21 FOR IDENTICAL B&W NEGATIVE. - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA

  16. 1. View of east elevation of power plant, radar tower ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. View of east elevation of power plant, radar tower in background, looking west - Naval Air Station Fallon, Power Plant, 800 Complex, off Carson Road near intersection of Pasture & Berney Roads, Fallon, Churchill County, NV

  17. 8. View of power plant and radar tower, looking southwest ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. View of power plant and radar tower, looking southwest - Naval Air Station Fallon, Power Plant, 800 Complex, off Carson Road near intersection of Pasture & Berney Roads, Fallon, Churchill County, NV

  18. WINGS OF BUILDING EXTENDING FROM TOWER SECTION, VIEW FACING SOUTHSOUTHEAST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    WINGS OF BUILDING EXTENDING FROM TOWER SECTION, VIEW FACING SOUTH-SOUTHEAST. - Naval Air Station Barbers Point, Administrative Office Building, Lexington Avenue north of Midway Street, Ewa, Honolulu County, HI

  19. 13. INTERIOR OF NORTHEAST PHOTO TOWER WITH WINDOW OPEN; ELECTRICAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. INTERIOR OF NORTHEAST PHOTO TOWER WITH WINDOW OPEN; ELECTRICAL POWER BOX BELOW WINDOW - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  20. Detail of parachute tower showing integration with main roof form, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of parachute tower showing integration with main roof form, facing southwest. - Albrook Air Force Station, Parachute & Armament Building, 200 feet north of Andrews Boulevard, Balboa, Former Panama Canal Zone, CZ

  1. Interior view at top of parachute drying tower showing original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view at top of parachute drying tower showing original steel wall-mounted ladder, facing southwest. - Albrook Air Force Station, Parachute & Armament Building, 200 feet north of Andrews Boulevard, Balboa, Former Panama Canal Zone, CZ

  2. Oblique view of south and east sides showing parachute tower, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Oblique view of south and east sides showing parachute tower, facing northwest. - Albrook Air Force Station, Parachute & Armament Building, 200 feet north of Andrews Boulevard, Balboa, Former Panama Canal Zone, CZ

  3. Airport Remote Tower Sensor Systems

    NASA Technical Reports Server (NTRS)

    Maluf, David A.; Gawdiak, Yuri; Leidichj, Christopher; Papasin, Richard; Tran, Peter B.; Bass, Kevin

    2006-01-01

    Networks of video cameras, meteorological sensors, and ancillary electronic equipment are under development in collaboration among NASA Ames Research Center, the Federal Aviation Administration (FAA), and the National Oceanic Atmospheric Administration (NOAA). These networks are to be established at and near airports to provide real-time information on local weather conditions that affect aircraft approaches and landings. The prototype network is an airport-approach-zone camera system (AAZCS), which has been deployed at San Francisco International Airport (SFO) and San Carlos Airport (SQL). The AAZCS includes remotely controlled color video cameras located on top of SFO and SQL air-traffic control towers. The cameras are controlled by the NOAA Center Weather Service Unit located at the Oakland Air Route Traffic Control Center and are accessible via a secure Web site. The AAZCS cameras can be zoomed and can be panned and tilted to cover a field of view 220 wide. The NOAA observer can see the sky condition as it is changing, thereby making possible a real-time evaluation of the conditions along the approach zones of SFO and SQL. The next-generation network, denoted a remote tower sensor system (RTSS), will soon be deployed at the Half Moon Bay Airport and a version of it will eventually be deployed at Los Angeles International Airport. In addition to remote control of video cameras via secure Web links, the RTSS offers realtime weather observations, remote sensing, portability, and a capability for deployment at remote and uninhabited sites. The RTSS can be used at airports that lack control towers, as well as at major airport hubs, to provide synthetic augmentation of vision for both local and remote operations under what would otherwise be conditions of low or even zero visibility.

  4. Drop Tower Workshop

    NASA Technical Reports Server (NTRS)

    Urban, David

    2013-01-01

    Ground based microgravity facilities are an important proving ground for space experiments, ground-based research and space hardware risk mitigation. An overview of existing platforms will be discussed with an emphasis on drop tower capabilities. The potential for extension to partial gravity conditions will be discussed. Input will be solicited from attendees for their potential to use drop towers in the future and the need for enhanced capabilities (e.g. partial gravity)

  5. Tower Mesonetwork Climatology and Interactive Display Tool

    NASA Technical Reports Server (NTRS)

    Case, Jonathan L.; Bauman, William H., III

    2004-01-01

    Forecasters at the 45th Weather Squadron and Spaceflight Meteorology Group use data from the tower network over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to evaluate Launch Commit Criteria, and issue and verify forecasts for ground operations. Systematic biases in these parameters could adversely affect an analysis, forecast, or verification. Also, substantial geographical variations in temperature and wind speed can occur under specific wind directions. To address these concerns, the Applied Meteorology Unit (AMU) developed a climatology of temperatures and winds from the tower network, and identified the geographical variation and significant tower biases. The mesoclimate is largely driven by the complex land-water interfaces across KSC/CCAFS. Towers with close proximity to water typically had much warmer nocturnal temperatures and higher wind speeds throughout the year. The strongest nocturnal wind speeds occurred from October to March whereas the strongest mean daytime wind speeds occurred from February to May. These results of this project can be viewed by forecasters through an interactive graphical user interface developed by the AMU. The web-based interface includes graphical and map displays of mean, standard deviation, bias, and data availability for any combination of towers, variables, months, hours, and wind directions.

  6. Ammonia stripping of biologically treated liquid manure.

    PubMed

    Alitalo, Anni; Kyrö, Aleksis; Aura, Erkki

    2012-01-01

    A prerequisite for efficient ammonia removal in air stripping is that the pH of the liquid to be stripped is sufficiently high. Swine manure pH is usually around 7. At pH 7 (at 20°C), only 0.4% of ammonium is in ammonia form, and it is necessary to raise the pH of swine slurry to achieve efficient ammonia removal. Because manure has a very high buffering capacity, large amounts of chemicals are needed to change the slurry pH. The present study showed that efficient air stripping of manure can be achieved with a small amount of chemicals and without strong bases like NaOH. Slurry was subjected to aerobic biological treatment to raise pH before stripping. This facilitated 8 to 32% ammonia removal without chemical treatment. The slurry was further subjected to repeated cycles of stripping with MgO and Ca(OH)(2) additions after the first and second strippings, respectively, to raise slurry pH in between the stripping cycles. After three consecutive stripping cycles, 59 to 86% of the original ammonium had been removed. It was shown that the reduction in buffer capacity of the slurry was due to ammonia and carbonate removal during the stripping cycles. PMID:22218195

  7. DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER TWO, WITH TOWERS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER TWO, WITH TOWERS THREE,FOUR, FIVE AND SIX IN DISTANCE, LOOKING NORTHEAST. - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA

  8. 46. OCTAGONAL & WEST TOWERS FROM SOUTH TOWER ROOF, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. OCTAGONAL & WEST TOWERS FROM SOUTH TOWER ROOF, LOOKING NORTHWEST, WITH WEST WING ROOF - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  9. 42. SOUTHEAST TOWER & EAST WING ROOF FROM SOUTH TOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. SOUTHEAST TOWER & EAST WING ROOF FROM SOUTH TOWER ROOF, LOOKING EAST BY NORTHEAST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  10. 41. SOUTHEAST TOWER & EAST WING FROM SOUTH TOWER ROOF, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. SOUTHEAST TOWER & EAST WING FROM SOUTH TOWER ROOF, LOOKING EAST BY NORTHEAST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  11. View of the north tower porte cochere and flag tower, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of the north tower porte cochere and flag tower, looking southwest (duplicate of HABS No. DC-141-19) - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  12. 45. OCTAGONAL, WEST & NORTHWEST TOWERS FROM SOUTH TOWER ROOF, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. OCTAGONAL, WEST & NORTHWEST TOWERS FROM SOUTH TOWER ROOF, LOOKING WEST BY NORTHWEST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  13. 3. VIEW NORTHWEST, height finder radar towers, and radar tower ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. VIEW NORTHWEST, height finder radar towers, and radar tower (unknown function) - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI

  14. 8. GENERAL VIEW OF TOWER 32, LEFT, AND TOWER 31, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. GENERAL VIEW OF TOWER 32, LEFT, AND TOWER 31, RIGHT. VIEW LOOKING NORTH SHOWING AERIAL WIRE DESIGN WITH VERTICAL 'TOP HAT' WIRES IN CENTER. - Chollas Heights Naval Radio Transmitting Facility, 6410 Zero Road, San Diego, San Diego County, CA

  15. 69. INTERIOR VIEW OF THE ABSORPTION TOWER BUILDING, ABSORPTION TOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    69. INTERIOR VIEW OF THE ABSORPTION TOWER BUILDING, ABSORPTION TOWER UNDER CONSTRUCTION. (DATE UNKNOWN). - United States Nitrate Plant No. 2, Reservation Road, Muscle Shoals, Muscle Shoals, Colbert County, AL

  16. Solar power towers

    SciTech Connect

    Not Available

    1998-04-01

    The high desert near Barstow, California, has witnessed the development of this country`s first two solar power towers. Solar One operated successfully from 1982 to 1988 and proved that power towers work efficiently to produce utility-scale power from sunlight. Solar Two was connected to the utility grid in 1996 and is operating today. Like its predecessor, Solar Two is rated at 10 megawatts. An upgrade of the Solar One plant, Solar Two demonstrates how solar energy can be stored in the form of heat in molten salt for power generation on demand. The experience gained with these two pilot power towers has established a foundation on which industry can develop its first commercial plants. These systems produce electricity on a large scale. They are unique among solar technologies because they can store energy efficiently and cost effectively. They can operate whenever the customer needs power, even after dark or during cloudy weather.

  17. Legionella in cooling towers.

    PubMed

    Witherell, L E; Novick, L F; Stone, K M; Duncan, R W; Orciari, L A; Kappel, S J; Jillson, D A

    1986-01-01

    Legionellosis (Legionnaires' disease and Pontiac fever) outbreaks have been associated with aerosols ejected from contaminated cooling towers--wet-type heat rejection units (WTHRUs) used to dissipate unwanted heat into the atmosphere. The Vermont Department of Health undertook a program to inventory, inspect, and sample all WTHRUs in Vermont from April 1981 to April 1982. All WTHRUs were sampled for Legionella pneumophila and data were obtained for location, design, construction, and operating characteristics. Of the 184 WTHRUs operating, statistical analyses were performed on those 130 which were sampled for L. pneumophila only once during the study period. Of these, 11 (8.5%) were positive for L. pneumophila. Sources of makeup water and period of operation had significant association with the recovery of L. pneumophila. Five out of 92 towers (5.4%) utilizing surface water sources for cooling were positive for L. pneumophila, in contrast to 6 positive towers of the 38 units (15.8%) which obtained makeup water from ground water sources (p = .054 by chi-square test). Nearly 15% of the 54 units which operated throughout the year were positive, compared to less than 4% of the 76 towers operating seasonally (p = .03 by chi-square test). The mean pH of the cooling water in units where L. pneumophila was recovered (8.3) was significantly higher than the mean pH of 7.9 in units testing negative (p less than .05 by t-test). In addition, the mean log-transformed turbidity of positive towers, 0.03 nephelometric units (ntu), was significantly lower than the mean of log turbidity of negative towers, 0.69 ntu (p less than .02 by t-test). PMID:10281778

  18. THE TOWER HOUSE, LOOKING WEST. The tower house provided a ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    THE TOWER HOUSE, LOOKING WEST. The tower house provided a water tank on the second floor that gravity fed water to the Kineth house and farm buildings. The one-story addition to the west of the tower provided workshop space. The hog shed is seen on the left of the image and the concrete foundation of the upright silo is in the foreground on the right. - Kineth Farm, Tower House, 19162 State Route 20, Coupeville, Island County, WA

  19. Combined-cycle power tower

    SciTech Connect

    Bohn, M S; Williams, T A; Price, H W

    1994-10-01

    This paper evaluates a new power tower concept that offers significant benefits for commercialization of power tower technology. The concept uses a molten nitrate salt centralreceiver plant to supply heat, in the form of combustion air preheat, to a conventional combined-cycle power plant. The evaluation focused on first commercial plants, examined three plant capacities (31, 100, and 300 MWe), and compared these plants with a solar-only 100-MWe plant and with gas-only combined-cycle plants in the same three capacities. Results of the analysis point to several benefits relative to the solar-only plant including low energy cost for first plants, low capital cost for first plants, reduced risk with respect to business uncertainties, and the potential for new markets. In addition, the concept appears to have minimal technology development requirements. Significantly, the results show that it is possible to build a first plant with this concept that can compete with existing gas-only combined-cycle plants.

  20. METHODOLOGIES FOR ESTIMATING AIR EMISSIONS FROM THREE NON-TRADITIONAL SOURCE CATEGORIES: OIL SPILLS, PETROLEUM VESSEL LOADING & UNLOADING, AND COOLING TOWERS

    EPA Science Inventory

    The report discusses part of EPA's program to identify and characterize emissions sources not currently accounted for by either the existing Aerometric Information Retrieval System (AIRS) or State Implementation Plan (sip) area source methodologies and to develop appropriate emis...

  1. Solar thermal power towers

    NASA Astrophysics Data System (ADS)

    Kreith, F.; Meyer, R. T.

    1984-07-01

    The solar thermal central receiver technology, known as solar power towers, is rapidly evolving to a state of near-term energy availability for electrical power generation and industrial process heat applications. The systems consist of field arrays of heliostat reflectors, a central receiver boiler, short term thermal storage devices, and either turbine-generators or heat exchangers. Fluid temperatures up to 550 C are currently achievable, and technology developments are underway to reach 1100 C. Six solar power towers are now under construction or in test operation in five countries around the world.

  2. 5. VIEW EAST, height finder radar towers, radar tower (unknown ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. VIEW EAST, height finder radar towers, radar tower (unknown function), prime search radar tower, operations building, and central heating plant - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI

  3. Evaporation Tower With Prill Nozzles

    NASA Technical Reports Server (NTRS)

    Du Fresne, E. R.

    1984-01-01

    Tower more efficient than conventional evaporation equipment. Liquids such as milk and fruit juice concentrated by passing them through tiny nozzle to form droplets, then allowing droplets to fall through evacuated tower with cooled walls.

  4. Engineering photochemical smog through convection towers

    SciTech Connect

    Elliott, S.; Prueitt, M.L.; Bossert, J.E.; Mroz, E.J.; Krakowski, R.A.; Miller, R.L.; Jacobson, M.Z.; Turco, R.P. |

    1995-02-01

    Reverse convection towers have attracted attention as a medium for cleansing modern cities. Evaporation of an aqueous mist injected at the tower opening could generate electrical power by creating descent, and simultaneously scavenge unsightly and unhealthful particulates. The study offered here assesses the influence to tower water droplets on the photochemical component of Los Angeles type smog. The primary radical chain initiator OH is likely removed into aqueous phases well within the residence time of air in the tower, and then reacts away rapidly. Organics do not dissolve, but nighttime hydrolysis of N{sub 2}O{sub 5} depletes the nitrogen oxides. A lack of HOx would slow hydrocarbon oxidation and so also ozone production. Lowering of NOx would also alter ozone production rates, but the direction is uncertain. SO{sub 2} is available in sufficient quantities in some urban areas to react with stable oxidants, and if seawater were the source of the mist, the high pH would lead to fast sulfur oxidation kinetics. With an accommodation coefficient of 10{sup {minus}3}, however, ozone may not enter the aqueous phase efficiently. Even if ozone is destroyed or its production suppressed, photochemical recovery times are on the order of hours, so that tower processing must be centered on a narrow midday time window. The cost of building the number of structures necessary for this brief turnover could be prohibitive. The increase in humidity accompanying mist evaporation could be controlled with condensers, but might otherwise counteract visibility enhancements by recreating aqueous aerosols. Quantification of the divergent forcings convection towers must exert upon the cityscape would call for coupled three dimensional modeling of transport, microphysics, and photochemistry. 112 refs.

  5. Ivory Basements and Ivory Towers

    ERIC Educational Resources Information Center

    Fitzgerald, Tanya

    2012-01-01

    The metaphors of the ivory tower and ivory basement are used in this chapter to reflect how many women understand and experience the academy. The ivory tower signifies a place that is protected, a place of privilege and authority and a place removed from the outside world (and consequently the rigours of the market place). The ivory tower, by…

  6. Cell Towers and Songbirds

    ERIC Educational Resources Information Center

    Klosterman, Michelle; Mesa, Jennifer; Milton, Katie

    2009-01-01

    This article describes how our common addiction to cell phones was used to launch a discussion about their use, impacts on the environment, and connections to issues of civic concern. By encouraging middle school science students to adopt the perspectives of special-interest groups debating communication tower restrictions designed to protect…

  7. Talking Towers, Making Withs.

    ERIC Educational Resources Information Center

    Lemke, J. L.

    The notion of a linguistic "register" is useful in posing questions about how the ways language is used differ from one kind of human activity to another. This paper analyzes a videotaped segment of male grade 4/5 students (n=3) who are talking as they work to build a tower from plastic drinking straws and pins. Discussion of the analysis…

  8. COOLING TOWER PLUME MODEL

    EPA Science Inventory

    A review of recently reported cooling tower plume models yields none that is universally accepted. The entrainment and drag mechanisms and the effect of moisture on the plume trajectory are phenomena which are treated differently by various investigators. In order to better under...

  9. The Ivory Tower Revisited

    ERIC Educational Resources Information Center

    Chantler, Abigail

    2016-01-01

    The corollary of the concept of the "ivory tower", as reflected in the writings of Plato and Newman amongst others, was, paradoxically, the vital importance of the university for wider society. Nevertheless from the mid-twentieth century, the esteem in which a "liberal" university education was held was diminished by rising…

  10. Augmented Reality Tower Technology Assessment

    NASA Technical Reports Server (NTRS)

    Reisman, Ronald J.; Brown, David M.

    2009-01-01

    Augmented Reality technology may help improve Air Traffic Control Tower efficiency and safety during low-visibility conditions. This paper presents the assessments of five off-duty controllers who shadow-controlled' with an augmented reality prototype in their own facility. Initial studies indicated unanimous agreement that this technology is potentially beneficial, though the prototype used in the study was not adequate for operational use. Some controllers agreed that augmented reality technology improved situational awareness, had potential to benefit clearance, control, and coordination tasks and duties and could be very useful for acquiring aircraft and weather information, particularly aircraft location, heading, and identification. The strongest objections to the prototype used in this study were directed at aircraft registration errors, unacceptable optical transparency, insufficient display performance in sunlight, inadequate representation of the static environment and insufficient symbology.

  11. PBF Cooling Tower detail. Camera facing southwest into north side ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Cooling Tower detail. Camera facing southwest into north side of Tower. Five horizontal layers of splash bars constitute fill decks, which will break up falling water into droplets, promoting evaporative cooling. Louvered faces, through which air enters tower, are on east and west sides. Louvers have been installed. Support framework for one of two venturi-shaped fan stacks (or "vents") is in center top. Orifices in hot basins (not in view) will distribute water over fill. Photographer: Kirsh. Date: May 15, 1969. INEEL negative no. 69-3032 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  12. Credit BG. West elevation of Test Stand "D" tower, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. West elevation of Test Stand "D" tower, with workshop on left, and tunnel entrance at right. Tower is accessed by exterior steel stairway; the vertical vacuum cell (Dv Cell) is obscured behind large square sunscreen. Below the sunscreen can be seen the end of the horizontal vacuum duct leading from the vacuum cell - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  13. Combined air stripper/membrane vapor separation systems. [Volatile organic compounds

    SciTech Connect

    Wijmans, J.G.; Baker, R.W.; Kamaruddin, H.D.; Kaschemekat, J.; Olsen, R.P.; Rose, M.E.; Segelke, S.V.

    1992-11-01

    Air stripping is an economical and efficient method of removing dissolved volatile organic compounds (VOCs) from contaminated groundwater. Air strippers, however, produce a vent air stream, which must meet the local air quality limits. If the VOC content exceeds the limits, direct discharge is not possible; therefore, a carbon adsorption VOC capture system is used to treat the vent air. This treatment step adds a cost of at least $50/lb of VOC captured. In this program, a combined air stripper/membrane vapor separation system was constructed and demonstrated in the laboratory. The membrane system captures VOCs from the stripper vent stream at a projected cost of $15/lb VOC for a water VOC content of 5 ppmw, and $75/lb VOC for a water VOC content of 1 ppmw. The VOCs are recovered as a small, concentrated liquid fraction for disposal or solvent recycling. The concept has been demonstrated in experiments with a system capable of handling up to 150,000 gpd of water. The existing demonstration system is available for field tests at a DOE facility or remediation site. Replacement of the current short air stripping tower (effective height 3 m) with a taller tower is recommended to improve VOC removal.

  14. 1. VIEW OF SOUTHEAST CORNER OF MOBILE SERVICE TOWER (MST). ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW OF SOUTHEAST CORNER OF MOBILE SERVICE TOWER (MST). CABLE TRAY SHED IN FOREGROUND. MICROWAVE ANTENNAS AND AIR-CONDITIONING PORCH ON EAST SIDE OF MST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  15. Varicose vein stripping

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/002952.htm Varicose vein stripping To use the sharing features on this ... enable JavaScript. Vein stripping is surgery to remove varicose veins in the legs. Description Varicose veins are swollen, ...

  16. Legionella in Puerto Rico cooling towers

    SciTech Connect

    Negron-Alviro, A.; Perez-Suarez, I.; Hazen, T.C.

    1988-12-31

    Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, Puerto Rico were assayed for various species and serogroups of Legionella spp. using direct immunofluorescence. Several water quality parameters were also measured with each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila (1-6), L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species, reaching 10{sup 5} cells/ml, within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (AODC), were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems, and without continuous biocide treatment may reach densities that present a health risk.

  17. Lateral flow strip assay

    SciTech Connect

    Miles, Robin R.; Benett, William J.; Coleman, Matthew A.; Pearson, Francesca S.; Nasarabadi, Shanavaz L.

    2011-03-08

    A lateral flow strip assay apparatus comprising a housing; a lateral flow strip in the housing, the lateral flow strip having a receiving portion; a sample collection unit; and a reagent reservoir. Saliva and/or buccal cells are collected from an individual using the sample collection unit. The sample collection unit is immersed in the reagent reservoir. The tip of the lateral flow strip is immersed in the reservoir and the reagent/sample mixture wicks up into the lateral flow strip to perform the assay.

  18. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  19. Peak Wind Forecasts for the Launch-Critical Wind Towers on Kennedy Space Center/Cape Canaveral Air Force Station, Phase IV

    NASA Technical Reports Server (NTRS)

    Crawford, Winifred

    2011-01-01

    This final report describes the development of a peak wind forecast tool to assist forecasters in determining the probability of violating launch commit criteria (LCC) at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS). The peak winds arc an important forecast clement for both the Space Shuttle and Expendable Launch Vehicle (ELV) programs. The LCC define specific peak wind thresholds for each launch operation that cannot be exceeded in order to ensure the safety of the vehicle. The 45th Weather Squadron (45 WS) has found that peak winds are a challenging parameter to forecast, particularly in the cool season months of October through April. Based on the importance of forecasting peak winds, the 45 WS tasked the Applied Meteorology Unit (AMU) to update the statistics in the current peak-wind forecast tool to assist in forecasting LCC violations. The tool includes onshore and offshore flow climatologies of the 5-minute mean and peak winds and probability distributions of the peak winds as a function of the 5-minute mean wind speeds.

  20. Surface and Tower Meteorological Instrumentation at Atqasuk (METTWR2H) Handbook

    SciTech Connect

    Ritsche, MT

    2006-01-01

    The Atqasuk meteorology station (AMET) uses mainly conventional in situ sensors to measure wind speed, wind direction, air temperature, dew point, and humidity mounted on a 10-m tower. It also obtains barometric pressure, visibility and precipitation data from sensors at or near the base of the tower. In addition, a chilled mirror hygrometer (CMH) is located at 1 m for comparison purposes. Temperature and relative humidity (RH) probes are mounted at 2 m and 5 m on the tower.

  1. The Physics of Shot Towers

    NASA Astrophysics Data System (ADS)

    Lipscombe, Trevor C.; Mungan, Carl E.

    2012-04-01

    In the late 18th and throughout the 19th century, lead shot for muskets was prepared by use of a shot tower. Molten lead was poured from the top of a tower and, during its fall, the drops became spherical under the action of surface tension. In this article, we ask and answer the question: How does the size of the lead shot depend on the height of the tower? In the process, we explain the basic technology underlying an important historical invention (the shot tower) and use simple physics (Newtonian mechanics and the thermodynamic laws of cooling) to model its operation.

  2. Towers of hybrid mesons

    SciTech Connect

    Semay, Claude; Buisseret, Fabien; Silvestre-Brac, Bernard

    2009-05-01

    A hybrid meson is a quark-antiquark pair in which, contrary to ordinary mesons, the gluon field is in an excited state. In the framework of constituent models, the interaction potential is assumed to be the energy of an excited string. An approximate, but accurate, analytical solution of the Schroedinger equation with such a potential is presented. When applied to hybrid charmonia and bottomonia, towers of states are predicted in which the masses are a linear function of a harmonic oscillator band number for the quark-antiquark pair. Such a formula could be a reliable guide for the experimental detection of heavy hybrid mesons.

  3. 2. Southern Light Tower and Northern Light Tower, view north, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Southern Light Tower and Northern Light Tower, view north, south sides - Kennebec River Light Station, South side of Doubling Point Road, off State Highway 127, 1.8 miles south of U.S. Route 1, Arrowsic, Sagadahoc County, ME

  4. Performance of the Integrated Tracker Towers of the GLAST Large Area Telescope

    SciTech Connect

    Brigida, M.; Caliandro, A.; Favuzzi, C.; Fusco, P.; Gargano, F.; Giglietto, N.; Giordano, F.; Loparco, F.; Marangelli, B.; Mazziotta, M.N.; Mirizzi, N.; Raino, S.; Spinelli, P.; /Bari U. /INFN, Bari

    2007-02-15

    The GLAST Large Area Telescope (LAT) is a high energy gamma ray observatory, mounted on a satellite that will be own in 2007. The LAT tracker consists of an array of tower modules, equipped with planes of silicon strip detectors (SSDs) interleaved with tungsten converter layers. Photon detection is based on the pair conversion process; silicon strip detectors will reconstruct tracks of electrons and positrons. The instrument is actually being assembled. The first towers have been already tested and integrated at Stanford Linear Accelerator Center (SLAC). An overview of the integration stages of the main components of the tracker and a description of the pre-launch tests will be given. Experimental results on the performance of the tracker towers will be also discussed.

  5. FLORIDA TOWER FOOTPRINT EXPERIMENTS

    SciTech Connect

    WATSON,T.B.; DIETZ, R.N.; WILKE, R.; HENDREY, G.; LEWIN, K.; NAGY, J.; LECLERC, M.

    2007-01-01

    The Florida Footprint experiments were a series of field programs in which perfluorocarbon tracers were released in different configurations centered on a flux tower to generate a data set that can be used to test transport and dispersion models. These models are used to determine the sources of the CO{sub 2} that cause the fluxes measured at eddy covariance towers. Experiments were conducted in a managed slash pine forest, 10 km northeast of Gainesville, Florida, in 2002, 2004, and 2006 and in atmospheric conditions that ranged from well mixed, to very stable, including the transition period between convective conditions at midday to stable conditions after sun set. There were a total of 15 experiments. The characteristics of the PFTs, details of sampling and analysis methods, quality control measures, and analytical statistics including confidence limits are presented. Details of the field programs including tracer release rates, tracer source configurations, and configuration of the samplers are discussed. The result of this experiment is a high quality, well documented tracer and meteorological data set that can be used to improve and validate canopy dispersion models.

  6. Anatomy comic strips.

    PubMed

    Park, Jin Seo; Kim, Dae Hyun; Chung, Min Suk

    2011-01-01

    Comics are powerful visual messages that convey immediate visceral meaning in ways that conventional texts often cannot. This article's authors created comic strips to teach anatomy more interestingly and effectively. Four-frame comic strips were conceptualized from a set of anatomy-related humorous stories gathered from the authors' collective imagination. The comics were drawn on paper and then recreated with digital graphics software. More than 500 comic strips have been drawn and labeled in Korean language, and some of them have been translated into English. All comic strips can be viewed on the Department of Anatomy homepage at the Ajou University School of Medicine, Suwon, Republic of Korea. The comic strips were written and drawn by experienced anatomists, and responses from viewers have generally been favorable. These anatomy comic strips, designed to help students learn the complexities of anatomy in a straightforward and humorous way, are expected to be improved further by the authors and other interested anatomists. PMID:21634024

  7. PBF Cooling Tower (PER720). Camera faces east to show west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Cooling Tower (PER-720). Camera faces east to show west facade. Sloped (louvered) panels in this and opposite facade allow air to enter tower and cool water falling on splash bars within. Date: August 2003. INEEL negative no. HD-35-10-2 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  8. The Drop Tower Bremen -Experiment Operation

    NASA Astrophysics Data System (ADS)

    Könemann, Thorben; von Kampen, Peter; Rath, Hans J.

    The idea behind the drop tower facility of the Center of Applied Space Technology and Micro-gravity (ZARM) in Bremen is to provide an inimitable technical opportunity of a daily access to short-term weightlessness on earth. In this way ZARM`s european unique ground-based microgravity laboratory displays an excellent economic alternative for research in space-related conditions at low costs comparable to orbital platforms. Many national and international ex-perimentalists motivated by these prospects decide to benefit from the high-quality and easy accessible microgravity environment only provided by the Drop Tower Bremen. Corresponding experiments in reduced gravity could open new perspectives of investigation methods and give scientists an impressive potential for a future technology and multidisciplinary applications on different research fields like Fundamental Physics, Astrophysics, Fluid Dynamics, Combus-tion, Material Science, Chemistry and Biology. Generally, realizing microgravity experiments at ZARM`s drop tower facility meet new requirements of the experimental hardware and may lead to some technical constraints in the setups. In any case the ZARM Drop Tower Operation and Service Company (ZARM FAB mbH) maintaining the drop tower facility is prepared to as-sist experimentalists by offering own air-conditioned laboratories, clean rooms, workshops and consulting engineers, as well as scientific personal. Furthermore, ZARM`s on-site apartment can be used for accommodations during the experiment campaigns. In terms of approaching drop tower experimenting, consulting of experimentalists is mandatory to successfully accomplish the pursued drop or catapult capsule experiment. For this purpose there will be a lot of expertise and help given by ZARM FAB mbH in strong cooperation to-gether with the experimentalists. However, in comparison to standard laboratory setups the drop or catapult capsule setup seems to be completely different at first view. While defining a

  9. Cooling towers for combined cycles: Design philosophy, performance testing, and operating problems

    NASA Astrophysics Data System (ADS)

    Bauthier, J.

    The characteristics and parameters affecting the choice of a type of cooling tower and its installation in the circuit of a combined cycle are discussed. The different possibilities of water circuits that are encountered are defined. Two modes of exchange and two types of fill are discussed. The various types of wet towers are described and their advantages and disadvantages considered. Factors affecting the selection of a cooling tower include: cost of energy versus cost of tower; performances; water availability and quality; emissions (water, noise, air, and vapor); site locations; and operating conditions.

  10. Pontiac fever outbreak associated with a cooling tower.

    PubMed Central

    Friedman, S; Spitalny, K; Barbaree, J; Faur, Y; McKinney, R

    1987-01-01

    In late April 1984, an outbreak of Pontiac fever was investigated in an office building in lower Manhattan (New York City). The outbreak was characterized by a high attack rate (78 per cent overall); the predominant symptoms were myalgias, chills, fatigue, fever, and headache. There was a clustering of cases in an office that was air cooled by a dedicated cooling tower separate from the remainder of the building. A high concentration of live L. Pneumophila cells in the cooling tower was quantified. Airborne spread via settle plates placed along the air intake system and within the office was demonstrated. Legionella pneumophila serogroup 1 antigen was found in the urine of two cases, and identical monoclonal antibody reactivity patterns of isolates from all sources was observed. Difficulty was experienced in eliminating the organism from the tower. PMID:3565648

  11. Short Duration Reduced Gravity Drop Tower Design and Development

    NASA Astrophysics Data System (ADS)

    Osborne, B.; Welch, C.

    The industrial and commercial development of space-related activities is intimately linked to the ability to conduct reduced gravity research. Reduced gravity experimentation is important to many diverse fields of research in the understanding of fundamental and applied aspects of physical phenomena. Both terrestrial and extra-terrestrial experimental facilities are currently available to allow researchers access to reduced gravity environments. This paper discusses two drop tower designs, a 2.0 second facility built in Australia and a proposed 2.2 second facility in the United Kingdom. Both drop towers utilise a drag shield for isolating the falling experiment from the drag forces of the air during the test. The design and development of The University of Queensland's (Australia) 2.0 second drop tower, including its specifications and operational procedures is discussed first. Sensitive aspects of the design process are examined. Future plans are then presented for a new short duration (2.2 sec) ground-based reduced gravity drop tower. The new drop tower has been designed for Kingston University (United Kingdom) to support teaching and research in the field of reduced gravity physics. The design has been informed by the previous UQ drop tower design process and utilises a catapult mechanism to increase test time and also incorporates features to allow participants for a variety of backgrounds (from high school students through to university researchers) to learn and experiment in reduced gravity. Operational performance expectations for this new facility are also discussed.

  12. Delta XTE Spacecraft Arrives at CCAS Skid Strip

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Footage shows the U.S Air Force Aircraft "Air Mobility Command" approaching, and landing at the Cape Canaveral Air Station Skid Strip (CCAS). The truck carrying the Delta XTE Spacecraft is also shown as it leaves the Air Mobility Command.

  13. Towers of Gravitational Theories

    NASA Astrophysics Data System (ADS)

    Goldberger, Walter D.; Rothstein, Ira Z.

    In this essay, we introduce a theoretical framework designed to describe black hole dynamics. The difficulties in understanding such dynamics stems from the proliferation of scales involved when one attempts to simultaneously describe all of the relevant dynamical degrees of freedom. These range from the modes that describe the black hole horizon, which are responsible for dissipative effects, to the long wavelength gravitational radiation that drains mechanical energy from macroscopic black hole bound states. We approach the problem from a Wilsonian point of view, by building a tower of theories of gravity each of which is valid at different scales. The methodology leads to multiple new results in diverse topics including phase transitions of Kaluza-Klein black holes and the interactions of spinning black hole in non-relativistic orbits. Moreover, our methods tie together speculative ideas regarding dualities for black hole horizons to real physical measurements in gravitational wave detectors.

  14. Towers of gravitational theories

    NASA Astrophysics Data System (ADS)

    Goldberger, Walter D.; Rothstein, Ira Z.

    2006-11-01

    In this essay we introduce a theoretical framework designed to describe black hole dynamics. The difficulties in understanding such dynamics stems from the proliferation of scales involved when one attempts to simultaneously describe all of the relevant dynamical degrees of freedom. These range from the modes that describe the black hole horizon, which are responsible for dissipative effects, to the long wavelength gravitational radiation that drains mechanical energy from macroscopic black hole bound states. We approach the problem from a Wilsonian point of view, by building a tower of theories of gravity each of which is valid at different scales. The methodology leads to multiple new results in diverse topics including phase transitions of Kaluza-Klein black holes and the interactions of spinning black hole in non-relativistic orbits. Moreover, our methods tie together speculative ideas regarding dualities for black hole horizons to real physical measurements in gravitational wave detectors.

  15. Anatomy Comic Strips

    ERIC Educational Resources Information Center

    Park, Jin Seo; Kim, Dae Hyun; Chung, Min Suk

    2011-01-01

    Comics are powerful visual messages that convey immediate visceral meaning in ways that conventional texts often cannot. This article's authors created comic strips to teach anatomy more interestingly and effectively. Four-frame comic strips were conceptualized from a set of anatomy-related humorous stories gathered from the authors' collective…

  16. Prefix Stripping Revisited.

    ERIC Educational Resources Information Center

    Taft, Marcus

    1981-01-01

    Presents and analyzes three experiments on prefix stripping. Results show that pseudoprefixed words are indiscriminately treated as prefixed words and concludes that prefix stripping does occur in word recognition and that prefixed words are accessed through a representation of their stem. (Author/BK)

  17. Science Comic Strips

    ERIC Educational Resources Information Center

    Kim, Dae Hyun; Jang, Hae Gwon; Shin, Dong Sun; Kim, Sun-Ja; Yoo, Chang Young; Chung, Min Suk

    2012-01-01

    Science comic strips entitled Dr. Scifun were planned to promote science jobs and studies among professionals (scientists, graduate and undergraduate students) and children. To this end, the authors collected intriguing science stories as the basis of scenarios, and drew four-cut comic strips, first on paper and subsequently as computer files.…

  18. 90. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    90. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO SUMP, LOWER RIGHT QUADRANT. DIAGONAL PIPE IN UPPER RIGHT IS AIR LINE TO AGITATORS. LAUNDER PARALLEL TO LEFT EDGE (FILLED WITH DEBRIS) RUNS FROM PRIMARY THICKENER No. 2 TO GOLD TANK No. 2. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  19. 169. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    169. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO SUMP, LOWER RIGHT QUADRANT. DIAGONAL PIPE IN UPPER RIGHT IS AIR LINE TO AGITATORS. LAUNDER PARALLEL TO LEFT EDGE (FILLED WITH DEBRIS) RUNS FROM PRIMARY THICKENER No. 2 TO GOLD TANK No. 2 - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  20. 77. VIEW OF COOLING TOWER NEAR NORTH FACE OR LSB ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    77. VIEW OF COOLING TOWER NEAR NORTH FACE OR LSB (BLDG. 779). MST ELECTRICAL CONNECTION PANEL ON LAUNCH DECK IN CENTER BACKGROUND. MST IN PARKED POSITION VISIBLE IN UPPER RIGHT CORNER OF PHOTO. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. Within compound, from Guard Tower, looking southeast, Power Plant (Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Within compound, from Guard Tower, looking southeast, Power Plant (Building 5761) to left, Satellite Communications Terminal (Building 5771) center, Supply Warehouse (Building 5768) to left - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  2. Indiana State University Graduates to Advanced Plastic Cooling Towers

    ERIC Educational Resources Information Center

    Sullivan, Ed

    2012-01-01

    Perhaps more than many other industries, today's universities and colleges are beset by dramatically rising costs on every front. One of the areas where overhead can be contained or reduced is in the operation of the chilled water systems that support air conditioning throughout college campuses, specifically the cooling towers. Like many…

  3. Exterior, looking west, Equipment Building to left, Tower at center, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Exterior, looking west, Equipment Building to left, Tower at center, Civil Engineering Storage Building (Building 5765) at left - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, Microwave Equipment Building, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  4. Interior view at top of parachute drying tower showing Lbeams ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior view at top of parachute drying tower showing L-beams and holes for hanging parachutes, and wooden roof construction, facing northeast. - Albrook Air Force Station, Parachute & Armament Building, 200 feet north of Andrews Boulevard, Balboa, Former Panama Canal Zone, CZ

  5. 6. SOUTH SIDE OF EAST TELEVISION CAMERA TOWER. A STORAGE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. SOUTH SIDE OF EAST TELEVISION CAMERA TOWER. A STORAGE SHED (BLDG. 776), THE PYROTECHNIC SHED (BLDG. 757), AND SLC-3W MST IN BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. PBF Cooling Tower. Hot deck of Cooling Tower with fan ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Cooling Tower. Hot deck of Cooling Tower with fan motors in place. Fan's propeller blades (not in view) rotate within lower portion of vents. Inlet pipe is a left of view. Contractor's construction buildings in view to right. Photographer: Larry Page. Date: June 30, 1969. INEEL negative no. 69-3781 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  7. Performance prediction of a multi-stage wind tower for indoor cooling

    NASA Astrophysics Data System (ADS)

    Issa, Roy J.; Chang, Byungik

    2012-08-01

    A theoretical model is developed to establish an in-depth understanding of the performance of a three-stage wind tower with a bypass system for indoor cooling in rural dry and hot climates. Model simulations are presented for a wide range of ambient conditions that include inlet wind speed, inlet temperature and relative humidity. Simulation results provide an insight into the desirable water flow rates and air-to-water loadings for comfort zone temperatures and relative humidity levels at the exit of the wind tower. Simulations show wind towers with variable cross-sections provide an increase in the cooling power for the same inlet wind speed, inlet air temperature and relative humidity when compared to wind towers with a constant cross-section. The study shall lead to a better understanding to designing wind towers that are both environmentally friendly and energy efficient.

  8. You're a What?: Tower Technician

    ERIC Educational Resources Information Center

    Vilorio, Dennis

    2012-01-01

    In this article, the author talks about the role and functions of a tower technician. A tower technician climbs up the face of telecommunications towers to remove, install, test, maintain, and repair a variety of equipment--from antennas to light bulbs. Tower technicians also build shelters and radiofrequency shields for electronic equipment, lay…

  9. Ozonation of cooling tower waters

    NASA Technical Reports Server (NTRS)

    Humphrey, M. F.; French, K. R.; Howe, R. D. (Inventor)

    1979-01-01

    Continuous ozone injection into water circulating between a cooling tower and heat exchanger with heavy scale deposits inhibits formation of further deposits, promotes flaking of existing deposits, inhibits chemical corrosion and controls algae and bacteria.

  10. United States Air Force 611th Civil Engineer Squadron, Elmendorf, AFB, Alaska. Final baseline risk assessment for the southeast runway fuel spill site and the control tower drum storage area, south

    SciTech Connect

    1996-03-01

    The addendum (Volume 4) presents an assessment of the current and possible future risks to human health and the environment potentially attributable to two additional IRP sites at Galena Airport: (1) The Southeast Runway Fuel Spill; and (2) The Control Tower Drum Storage Area, South (CTDSA).

  11. The Physics of Shot Towers

    ERIC Educational Resources Information Center

    Lipscombe, Trevor C.; Mungan, Carl E.

    2012-01-01

    In the late 18th and throughout the 19th century, lead shot for muskets was prepared by use of a shot tower. Molten lead was poured from the top of a tower and, during its fall, the drops became spherical under the action of surface tension. In this article, we ask and answer the question: "How does the size of the lead shot depend on the height…

  12. CFD MODELING ANALYSIS OF MECHANICAL DRAFT COOLING TOWER

    SciTech Connect

    Lee, S; Alfred Garrett, A; James02 Bollinger, J; Larry Koffman, L

    2008-03-03

    Industrial processes use mechanical draft cooling towers (MDCT's) to dissipate waste heat by transferring heat from water to air via evaporative cooling, which causes air humidification. The Savannah River Site (SRS) has a MDCT consisting of four independent compartments called cells. Each cell has its own fan to help maximize heat transfer between ambient air and circulated water. The primary objective of the work is to conduct a parametric study for cooling tower performance under different fan speeds and ambient air conditions. The Savannah River National Laboratory (SRNL) developed a computational fluid dynamics (CFD) model to achieve the objective. The model uses three-dimensional steady-state momentum, continuity equations, air-vapor species balance equation, and two-equation turbulence as the basic governing equations. It was assumed that vapor phase is always transported by the continuous air phase with no slip velocity. In this case, water droplet component was considered as discrete phase for the interfacial heat and mass transfer via Lagrangian approach. Thus, the air-vapor mixture model with discrete water droplet phase is used for the analysis. A series of the modeling calculations was performed to investigate the impact of ambient and operating conditions on the thermal performance of the cooling tower when fans were operating and when they were turned off. The model was benchmarked against the literature data and the SRS test results for key parameters such as air temperature and humidity at the tower exit and water temperature for given ambient conditions. Detailed results will be presented here.

  13. Excimer laser photoresist stripping

    NASA Astrophysics Data System (ADS)

    Genut, Menachem; Tehar-Zahav, Ofer; Iskevitch, Eli; Livshits, Boris

    1996-06-01

    A new method for stripping the most challenging photoresists on deep sub-micron technology semiconductor wafers has been developed. The method uses a combination of UV excimer laser ablation and reactive chemistry to strip the photoresist in a single dry process, eliminating the wet acids or solvents often used following ashing of high dose implantation (HDI) and reactive ion etching (RIE). The stripping process combines new removal mechanisms: chemical assisted UV excimer laser ablation/etching, laser induced chemical etching of side walls and residues, and enhanced combustion. During the laser pulses photolysis of the process gas occurs, UV laser radiation breaks the photoresist polymer chain bonds, and the photoresist (including foreign materials imbedded in it) is ablated. The combustion is ignited by the ablative impact of laser radiation and enhanced by the radicals formed during photo-thermal decomposition of the process gases. Following this process, the volatilized products and gases are evacuated. The optimum laser stripping conditions were developed to provide a wide process window for the most challenging stripping conditions, such as after HDI and RIE (metal, polysilicon), without causing damage to the wafer devices. A photoresist stripping system based on the described technology was designed and built. The system has been designated as the L-StripperTM and provides stripping time of 0.15 s/(micrometer cm2).

  14. Tower Temperature and Humidity Sensors (TWR) Handbook

    SciTech Connect

    Cook, DR

    2010-02-01

    Three tall towers are installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility: a 60-meter triangular tower at the Southern Great Plains (SGP) Central Facility (CF), a 21-meter walkup scaffolding tower at the SGP Okmulgee forest site (E21), and a 40-meter triangular tower at the North Slope of Alaska (NSA) Barrow site. The towers are used for meteorological, radiological, and other measurements.

  15. Virtual Environment Design for Low/Zero Visibility Tower Tools

    NASA Technical Reports Server (NTRS)

    Reisman, Ron; Farouk, Ahmed; Edwards, Thomas A. (Technical Monitor)

    1998-01-01

    This paper describes prototype software for three-dimensional display of aircraft movement based on realtime radar and other Air Traffic Control (ATC) information. This prototype can be used to develop operational tools for controllers in ATC Towers who cannot view aircraft in low or zero visibility (LZV) weather conditions. The controller could also use the software to arbitrarily reposition his virtual eyepoint to overcome physical obstructions or increase situation awareness. The LZV Tower tool prototype consists of server and client components. The server interfaces to operational ATC radar and communications systems, sending processed data to a client process written in java. This client process runs under Netscape Communicator to provide an interactive perspective display of aircraft in the airport environment. Prototype VRML airport models were derived from 3-D databases used in FAA-certified high fidelity flight-simulators. The web-based design offers potential efficiency increases and decreased costs in the development and deployment of operational LZV Tower tools.

  16. A Meso-Climatology Study of the High-Resolution Tower Network Over the Florida Spaceport

    NASA Technical Reports Server (NTRS)

    Case, Jonathan L.; Bauman, William H., III

    2004-01-01

    Forecasters at the US Air Force 45th Weather Squadron (45 WS) use wind and temperature data from the tower network over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to evaluate Launch Commit Criteria and to issue and verify temperature and wind advisories, watches, and warnings for ground operations. The Spaceflight Meteorology Group at the Johnson Space Center in Houston, TX also uses these data when issuing forecasts for shuttle landings at the KSC Shuttle Landing Facility. Systematic biases in these parameters at any of the towers could adversely affect an analysis, forecast, or verification for all of these operations. In addition, substantial geographical variations in temperature and wind speed can occur under specific wind directions. Therefore, the Applied Meteorology Unit (AMU), operated by ENSCO Inc., was tasked to develop a monthly and hourly climatology of temperatures and winds from the tower network, and identify the geographical variation, tower biases, and the magnitude of those biases. This paper presents a sub-set of results from a nine-year climatology of the KSC/CCAFS tower network, highlighting the geographical variations based on location, month, times of day, and specific wind direction regime. Section 2 provides a description of the tower mesonetwork and instrumentation characteristics. Section 3 presents the methodology used to construct the tower climatology including QC methods and data processing. The results of the tower climatology are presented in Section 4 and Section 5 summarizes the paper.

  17. Deployable tensegrity towers

    NASA Astrophysics Data System (ADS)

    Pinaud, Jean-Paul

    The design of a complete tensegrity system involves the analysis of static equilibria, the mechanical properties of the configuration, the deployment of the structure, and the regulation and dynamics of the system. This dissertation will explore these steps for two different types of structures. The first structure is the traditional Snelson Tower, where struts are disjointed, and is referred to as a Class 1 tensegrity. The second structure of interest is referred to as a Class 2 structure, where two struts come in contact at a joint. The first part of the thesis involves the dynamics of these tensegrity structures. Two complete nonlinear formulations for the dynamics of tensegrity systems are derived. In addition, a general formulation for the statics for an arbitrary tensegrity structure resulted from one of the dynamic formulations and is presented with symmetric and nonsymmetric tensegrity configurations. The second part of the thesis involves statics. The analysis of static equilibria and the implementation of this analysis into an open loop control law that will deploy the tensegrity structures along an equilibrium manifold are derived. The analysis of small stable tensegrity units allow for a modular design, where a collection of these units can be assembled into a larger structure that obeys the same control laws for deployment concepts. In addition, a loaded structure is analyzed to determine the optimal number of units required to obtain a minimal mass configuration. The third part of the thesis involves laboratory hardware that demonstrates the practical use of the methodology presented. A Class 2 symmetric structure is constructed, deployed, and stowed using the analysis from part two. In addition, the static equilibria of a Class 1 structure is computed to obtain nonsymmetric reconfigurations. The final part of the thesis involves the attenuation of white noise disturbances acting on nodes of both structures. The structures are simulated using linear

  18. Geometrical deuteron stripping revisited

    SciTech Connect

    Neoh, Y. S.; Yap, S. L.

    2014-03-05

    We investigate the reality of the idea of geometrical deuteron stripping originally envisioned by Serber. By taking into account of realistic deuteron wavefunction, nuclear density, and nucleon stopping mean free path, we are able to estimate inclusive deuteron stripping cross section for deuteron energy up to before pion production. Our semiclassical model contains only one global parameter constant for all nuclei which can be approximated by Woods-Saxon or any other spherically symmetric density distribution.

  19. Spatial Representativeness of Flux Tower Sites: A Comparison Between Tower and Aircraft Eddy-Covariance Fluxes

    NASA Astrophysics Data System (ADS)

    Caulton, D.; Shepson, P. B.; Munger, J. W.; Hollinger, D. Y.; Saatchi, S. S.; Moghaddam, M.; Stirm, B. H.

    2013-12-01

    Development and testing of regional and global scale ecosystem models rely on analysis of data from flux towers that have footprint scales (~1 km2) that are much smaller and contain relatively homogeneous land use types. This approach tends to assume that the patchwork approach appropriately represents regions that are, especially on larger scale, much more heterogeneous in terms of land cover, soil moisture, topography and climatology, etc. While aircraft platforms provide snapshot views of NEE, they have access to essentially any environment and can access difficult and heterogeneous environments. We used an instrumented aircraft platform equipped with a 50 Hz wind probe and GPS/INS and a 10 Hz Picarro CO2/H2O analyzer to measure eddy covariance fluxes over larger spatial scales (~20 km2) over and near Howland Forest, ME, Harvard Forest, MA and Duke Forest, NC, as part of the Airborne Observatory of Subcanopy and Subsurface (AirMOSS) mission campaigns. Flux measurements were conducted for varying land cover types in these forests in July, 2012 and June-August, 2013. Measured fluxes will be compared with tower fluxes from each of the three sites to investigate the quality of the aircraft data, and the ability to assess local-regional scale variability and the spatial representativeness of these towers, with respect to the larger scale fluxes. In addition, soil moisture data from a NASA G-III aircraft will be used to investigate spatial representativeness and the soil moisture dependence of the fluxes.

  20. Towers for Offshore Wind Turbines

    NASA Astrophysics Data System (ADS)

    Kurian, V. J.; Narayanan, S. P.; Ganapathy, C.

    2010-06-01

    Increasing energy demand coupled with pollution free production of energy has found a viable solution in wind energy. Land based windmills have been utilized for power generation for more than two thousand years. In modern times wind generated power has become popular in many countries. Offshore wind turbines are being used in a number of countries to tap the energy from wind over the oceans and convert to electric energy. The advantages of offshore wind turbines as compared to land are that offshore winds flow at higher speed than onshore winds and the more available space. In some land based settings, for better efficiency, turbines are separated as much as 10 rotor diameters from each other. In offshore applications where only two wind directions are likely to predominate, the distances between the turbines arranged in a line can be shortened to as little as two or four rotor diameters. Today, more than a dozen offshore European wind facilities with turbine ratings of 450 kw to 3.6 MW exist offshore in very shallow waters of 5 to 12 m. Compared to onshore wind turbines, offshore wind turbines are bigger and the tower height in offshore are in the range of 60 to 80 m. The water depths in oceans where offshore turbines can be located are within 30 m. However as the distance from land increases, the costs of building and maintaining the turbines and transmitting the power back to shore also increase sharply. The objective of this paper is to review the parameters of design for the maximum efficiency of offshore wind turbines and to develop types offshore towers to support the wind turbines. The methodology of design of offshore towers to support the wind turbine would be given and the environmental loads for the design of the towers would be calculated for specific cases. The marine corrosion on the towers and the methods to control the corrosion also would be briefly presented. As the wind speeds tend to increase with distance from the shore, turbines build father

  1. Tower-supported solar-energy collector

    NASA Technical Reports Server (NTRS)

    Selcuk, M. K.

    1977-01-01

    Multiple-collector tower system supports three receiver/concentrators that absorb solar energy reflected from surrounding field of heliostats. System overcomes disadvantages of tower-supported collectors. Booms can be lowered during heavy winds to protect arms and collectors.

  2. Method and system for simulating heat and mass transfer in cooling towers

    DOEpatents

    Bharathan, Desikan; Hassani, A. Vahab

    1997-01-01

    The present invention is a system and method for simulating the performance of a cooling tower. More precisely, the simulator of the present invention predicts values related to the heat and mass transfer from a liquid (e.g., water) to a gas (e.g., air) when provided with input data related to a cooling tower design. In particular, the simulator accepts input data regarding: (a) cooling tower site environmental characteristics; (b) cooling tower operational characteristics; and (c) geometric characteristics of the packing used to increase the surface area within the cooling tower upon which the heat and mass transfer interactions occur. In providing such performance predictions, the simulator performs computations related to the physics of heat and mass transfer within the packing. Thus, instead of relying solely on trial and error wherein various packing geometries are tested during construction of the cooling tower, the packing geometries for a proposed cooling tower can be simulated for use in selecting a desired packing geometry for the cooling tower.

  3. 29 CFR 1926.1435 - Tower cranes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 8 2011-07-01 2011-07-01 false Tower cranes. 1926.1435 Section 1926.1435 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1435 Tower cranes. (a) This section contains supplemental requirements for tower cranes; all sections of...

  4. 29 CFR 1926.1435 - Tower cranes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Tower cranes. 1926.1435 Section 1926.1435 Labor Regulations...) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Cranes and Derricks in Construction § 1926.1435 Tower cranes. (a) This section contains supplemental requirements for tower cranes; all sections of...

  5. Cooling tower hardware corrosion studies

    SciTech Connect

    Blue, S.C.

    1983-01-31

    The data presented in this report are interim results of a continuing investigation into the corrosion resistance of metals in the environment of a large cooling tower. Some of the significant observations are as follows: the corrosion of susceptible metals occurs most rapidly in the warm fog conditions between the deck and mist filters; the application of stainless steel must be made on the basis of alloy chemistry and processing history. Some corrosion resistant alloys may develop cracking problems after improper heat treating or welding; combinations of aluminum bronze, stainless steel, and silicon bronze hardware were not susceptible to galvanic corrosion; the service life of structural steel is extended by coal tar epoxy coatings; aluminum coatings appear to protect structural steel on the tower deck and below the distribution nozzles. The corrosion of cooling tower hardware can be easily controlled through the use of 316 stainless steel and silicon bronze. The use of other materials which exhibit general resistance should be specified only after they have been tested in the form of structural assemblies such as weldments and bolted joints in each of the different tower zones.

  6. Mastering Interproximal Stripping: With Innovations in Slenderization

    PubMed Central

    Shrivastav, Sunita S; Hazarey, Pushpa V

    2012-01-01

    ABSTRACT Crowding and irregularity remain a consistent problem for children. Management of space problems continues to play an important role in a dental practice. It also represents an area of major interaction between the primary provider and the specialists. Proximal stripping is routinely carried out to avoid extraction in borderline cases where space discrepancy is less and in cases where there is a discrepancy between the mesio- distal width of maxillary and mandibular teeth to satisfy Bolton ratio. Proximal stripping is carried out using of metallic abrasive strip, safe sided carborundum disk, or with long thin tapered fissure burs with air rotor. The use of rotary cutting instrument can harm the pulp by exposure of mechanical vibration and heat generation (in some cases). Whereas, the large diameter of the disk obstructs vision of the working area. Also fracturing away a portion is a common problem with disk. Tapered fissure burs cut the tooth structure as the width of bur or overcutting may occur of the tooth structure due to high speed. The use of metallic abrasive strip is the safest procedure amongst the above. The strip can be placed in the anterior region without any difficulty but using it in the posterior region is difficult as, it is difficult to hold it with fingers while stripping the posterior teeth. To avoid this inconvenience here with a simple and economical way of fabricating strip holder from routine lab material is presented. Clinical implications: Proper management of space in the primary and mixed dentitions can prevent unnecessary loss in arch length. Diagnosing and treating space problems requires an understanding of the etiology of crowding and the development of the dentition to render treatment for the mild, moderate and severe crowding cases. Most crowding problems with less than 4.5 mm can be resolved through preservation of the leeway space, regaining space or limited expansion in the late mixed dentition. In cases with 5 to 9 mm

  7. Investigation of Natural Draft Cooling Tower Performance Using Neural Network

    NASA Astrophysics Data System (ADS)

    Mahdi, Qasim S.; Saleh, Saad M.; Khalaf, Basima S.

    In the present work Artificial Neural Network (ANN) technique is used to investigate the performance of Natural Draft Wet Cooling Tower (NDWCT). Many factors are affected the rang, approach, pressure drop, and effectiveness of the cooling tower which are; fill type, water flow rate, air flow rate, inlet water temperature, wet bulb temperature of air, and nozzle hole diameter. Experimental data included the effects of these factors are used to train the network using Back Propagation (BP) algorithm. The network included seven input variables (Twi, hfill, mw, Taiwb, Taidb, vlow, vup) and five output variables (ma, Taowb, Two, Δp, ɛ) while hidden layer is different for each case. Network results compared with experimental results and good agreement was observed between the experimental and theoretical results.

  8. Emissions characteristics of cooling towers using reclaimed wastewater in california. Final report, July 1979-July 1981

    SciTech Connect

    Rogozen, M.B.; Phillips, A.R.; Guttman, M.A.; Shokes, R.F.; Fargo, L.

    1981-08-11

    Present and planned use of reclaimed municipal wastewater, industrial process water, and geothermal condensate as makeup to cooling towers have raised questions about the potential for atmospheric emissions of pathogenic microorganisms, organic compounds, heavy metals, and other wastewater constituents. In this study, the makeup and circulating water of six towers were sampled and analyzed for indicator bacteria and virus, volatile and nonvolatile organic compounds, metals, and other components of potential concern. Further water sampling and exhaust air emissions tests were then conducted on four of the towers; for the microbiological emissions tests, a special isokinetic sampling device was developed and employed.

  9. Influence of the gas composition on the efficiency of ammonia stripping of biogas digestate.

    PubMed

    Bousek, J; Scroccaro, D; Sima, Jan; Weissenbacher, Norbert; Fuchs, W

    2016-03-01

    Impact of strip gas composition on side stream ammonia stripping, a technology aiming at the reduction of high ammonia levels in anaerobic reactors, was investigated. Evaluation of the effect of oxygen contact during air stripping showed a distinct, though lower than perceived, inhibition of anaerobic microflora. To circumvent, the feasibility and possible constraints of biogas and flue gas as alternatives in side stream stripping were studied. Experiments, with ammonia bicarbonate model solution and digestate, were conducted. It was demonstrated that the stripping performance is negatively correlated to the CO2 level in the strip gas with a progressive performance loss towards higher concentrations. In contrast to biogas with its high CO2 content, the efficiency reduction observed for flue gas was significantly less pronounced. The later provides the additional benefit that its high thermal energy can be re-utilized in the stripping unit and it is therefore considered a viable alternative for air. PMID:26735881

  10. Strip and load data

    NASA Technical Reports Server (NTRS)

    Jones, R. H.

    1984-01-01

    The method of taking batch data files and loading these files into the ADABAS data base management system (DBMS) is examined. This strip and load process allows the user to quickly become productive. Techniques for data fields and files definition are also included.

  11. Retractable barrier strip

    DOEpatents

    Marts, Donna J.; Barker, Stacey G.; McQueen, Miles A.

    1996-01-01

    A portable barrier strip having retractable tire-puncture means for puncturing a vehicle tire. The tire-puncture means, such as spikes, have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture means removably disposed in a shaft that is rotatably disposed in each barrier block. The shaft removably and pivotally interconnects the plurality of barrier blocks. Actuation cables cause the shaft to rotate the tire-puncture means to the armed position for puncturing a vehicle tire and to the retracted position for not puncturing the tire. Each tire-puncture means is received in a hollow-bed portion of its respective barrier block when in the retracted position. The barrier strip rests stable in its deployed position and substantially motionless as a tire rolls thereon and over. The strip is rolled up for retrieval, portability, and storage purposes, and extended and unrolled in its deployed position for use.

  12. Retractable barrier strip

    DOEpatents

    Marts, Donna J.; Barker, Stacey G.; Wowczuk, Andrew; Vellenoweth, Thomas E.

    2002-01-01

    A portable barrier strip having retractable tire-puncture spikes for puncturing a vehicle tire. The tire-puncture spikes have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture spikes removably disposed in a shaft that is rotatably disposed in each barrier block. The plurality of barrier blocks hare hingedly interconnected by complementary hinges integrally formed into the side of each barrier block which allow the strip to be rolled for easy storage and retrieval, but which prevent irregular or back bending of the strip. The shafts of adjacent barrier blocks are pivotally interconnected via a double hinged universal joint to accommodate irregularities in a roadway surface and to transmit torsional motion of the shaft from block to block. A single flexshaft cable is connected to the shaft of an end block to allow a user to selectively cause the shafts of a plurality of adjacently connected barrier blocks to rotate the tire-puncture spikes to the armed position for puncturing a vehicle tire, and to the retracted position for not puncturing the tire. The flexshaft is provided with a resiliently biased retracting mechanism, and a release latch for allowing the spikes to be quickly retracted after the intended vehicle tire is punctured.

  13. Retractable barrier strip

    DOEpatents

    Marts, D.J.; Barker, S.G.; McQueen, M.A.

    1996-04-16

    A portable barrier strip is described having retractable tire-puncture means for puncturing a vehicle tire. The tire-puncture means, such as spikes, have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture means removably disposed in a shaft that is rotatably disposed in each barrier block. The shaft removably and pivotally interconnects the plurality of barrier blocks. Actuation cables cause the shaft to rotate the tire-puncture means to the armed position for puncturing a vehicle tire and to the retracted position for not puncturing the tire. Each tire-puncture means is received in a hollow-bed portion of its respective barrier block when in the retracted position. The barrier strip rests in its deployed position and substantially motionless as a tire rolls thereon and over. The strip is rolled up for retrieval, portability, and storage purposes, and extended and unrolled in its deployed position for use. 13 figs.

  14. Surface and Tower Meteorological Instrumentation at Barrow (METTWR4H) Handbook

    SciTech Connect

    Ritsche, MT

    2008-04-01

    The Barrow meteorology station (BMET) uses mainly conventional in situ sensors mounted at four different heights (2m, 10m, 20m and 40m) on a 40 m tower to obtain profiles of wind speed, wind direction, air temperature, dew point and humidity. It also obtains barometric pressure, visibility and precipitation data from sensors at the base of the tower. Additionally, a Chilled Mirror Hygrometer and an Ultrasonic wind speed sensor are located near the 2m level for comparison purposes.

  15. Hydrogen Storage in Wind Turbine Towers

    SciTech Connect

    Kottenstette, R.; Cotrell, J.

    2003-09-01

    Low-cost hydrogen storage is recognized as a cornerstone of a renewables-hydrogen economy. Modern utility-scale wind turbine towers are typically conical steel structures that, in addition to supporting the rotor, could be used to store hydrogen. This study has three objectives: (1) Identify the paramount considerations associated with using a wind turbine tower for hydrogen storage; (2)Propose and analyze a cost-effective design for a hydrogen-storing tower; and (3) Compare the cost of storage in hydrogen towers to the cost of storage in conventional pressure vessels. The paramount considerations associated with a hydrogen tower are corrosion (in the form of hydrogen embrittlement) and structural failure (through bursting or fatigue life degradation). Although hydrogen embrittlement (HE) requires more research, it does not appear to prohibit the use of turbine towers for hydrogen storage. Furthermore, the structural modifications required to store hydrogen in a tower are not cost prohibitive.

  16. Airport Remote Tower Sensor Systems

    NASA Technical Reports Server (NTRS)

    Papasin, Richard; Gawdiak, Yuri; Maluf, David A.; Leidich, Christopher; Tran, Peter B.

    2001-01-01

    Remote Tower Sensor Systems (RTSS) are proof-of-concept prototypes being developed by NASA/Ames Research Center (NASA/ARC) with collaboration with the FAA (Federal Aviation Administration) and NOAA (National Oceanic Atmospheric Administration). RTSS began with the deployment of an Airport Approach Zone Camera System that includes real-time weather observations at San Francisco International Airport. The goal of this research is to develop, deploy, and demonstrate remotely operated cameras and sensors at several major airport hubs and un-towered airports. RTSS can provide real-time weather observations of airport approach zone. RTSS will integrate and test airport sensor packages that will allow remote access to realtime airport conditions and aircraft status.

  17. Ozone Treatment For Cooling Towers

    NASA Technical Reports Server (NTRS)

    Blackwelder, Rick; Baldwin, Leroy V.; Feeney, Ellen S.

    1990-01-01

    Report presents results of study of cooling tower in which water treated with ozone instead of usual chemical agents. Bacteria and scale reduced without pollution and at low cost. Operating and maintenance costs with treatment about 30 percent of those of treatment by other chemicals. Corrosion rates no greater than with other chemicals. Advantage of ozone, even though poisonous, quickly detected by smell in very low concentrations.

  18. Gated strip proportional detector

    DOEpatents

    Morris, Christopher L.; Idzorek, George C.; Atencio, Leroy G.

    1987-01-01

    A gated strip proportional detector includes a gas tight chamber which encloses a solid ground plane, a wire anode plane, a wire gating plane, and a multiconductor cathode plane. The anode plane amplifies the amount of charge deposited in the chamber by a factor of up to 10.sup.6. The gating plane allows only charge within a narrow strip to reach the cathode. The cathode plane collects the charge allowed to pass through the gating plane on a set of conductors perpendicular to the open-gated region. By scanning the open-gated region across the chamber and reading out the charge collected on the cathode conductors after a suitable integration time for each location of the gate, a two-dimensional image of the intensity of the ionizing radiation incident on the detector can be made.

  19. Gated strip proportional detector

    DOEpatents

    Morris, C.L.; Idzorek, G.C.; Atencio, L.G.

    1985-02-19

    A gated strip proportional detector includes a gas tight chamber which encloses a solid ground plane, a wire anode plane, a wire gating plane, and a multiconductor cathode plane. The anode plane amplifies the amount of charge deposited in the chamber by a factor of up to 10/sup 6/. The gating plane allows only charge within a narrow strip to reach the cathode. The cathode plane collects the charge allowed to pass through the gating plane on a set of conductors perpendicular to the open-gated region. By scanning the open-gated region across the chamber and reading out the charge collected on the cathode conductors after a suitable integration time for each location of the gate, a two-dimensional image of the intensity of the ionizing radiation incident on the detector can be made.

  20. Use of Air2Air Technology to Recover Fresh-Water from the Normal Evaporative Cooling Loss at Coal-Based Thermoelectric Power Plants

    SciTech Connect

    Ken Mortensen

    2009-06-30

    This program was undertaken to build and operate the first Air2Air{trademark} Water Conservation Cooling Tower at a power plant, giving a validated basis and capability for water conservation by this method. Air2Air{trademark} water conservation technology recovers a portion of the traditional cooling tower evaporate. The Condensing Module provides an air-to-air heat exchanger above the wet fill media, extracting the heat from the hot saturated moist air leaving in the cooling tower and condensing water. The rate of evaporate water recovery is typically 10%-25% annually, depending on the cooling tower location (climate).

  1. 'Towers in the Tempest' Computer Animation Submission

    NASA Technical Reports Server (NTRS)

    Shirah, Greg

    2008-01-01

    The following describes a computer animation that has been submitted to the ACM/SIGGRAPH 2008 computer graphics conference: 'Towers in the Tempest' clearly communicates recent scientific research into how hurricanes intensify. This intensification can be caused by a phenomenon called a 'hot tower.' For the first time, research meteorologists have run complex atmospheric simulations at a very fine temporal resolution of 3 minutes. Combining this simulation data with satellite observations enables detailed study of 'hot towers.' The science of 'hot towers' is described using: satellite observation data, conceptual illustrations, and a volumetric atmospheric simulation data. The movie starts by showing a 'hot tower' observed by NASA's Tropical Rainfall Measuring Mission (TRMM) spacecraft's three dimensional precipitation radar data of Hurricane Bonnie. Next, the dynamics of a hurricane and the formation of 'hot towers' are briefly explained using conceptual illustrations. Finally, volumetric cloud, wind, and vorticity data from a supercomputer simulation of Hurricane Bonnie are shown using volume techniques such as ray marching.

  2. 1. Light tower/keeper's house and abandoned light tower, view northwest, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Light tower/keeper's house and abandoned light tower, view northwest, south southeast and east northeast sides - Matinicus Rock Light Station, Matinicus Island, on Matinicus Rock, Matinicus, Knox County, ME

  3. 2. Abandoned light tower and keeper's house/light tower, view southeast, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Abandoned light tower and keeper's house/light tower, view southeast, north northwest and west southwest sides - Matinicus Rock Light Station, Matinicus Island, on Matinicus Rock, Matinicus, Knox County, ME

  4. The GLAST Silicon-Strip Tracking System

    SciTech Connect

    Johnson, R

    2004-09-30

    The GLAST instrument concept is a gamma-ray pair conversion telescope that uses silicon microstrip detector technology to track the electron-positron pairs resulting from gamma ray conversions in thin lead foils. A cesium iodide calorimeter following the tracker is used to measure the gamma-ray energy. Silicon strip technology is mature and robust, with an excellent heritage in space science and particle physics. It has many characteristics important for optimal performance of a pair conversion telescope, including high efficiency in thin detector planes, low noise, and excellent resolution and two-track separation. The large size of GLAST and high channel count in the tracker puts demands on the readout technology to operate at very low power, yet with sufficiently low noise occupancy to allow self triggering. A prototype system employing custom-designed ASIC's has been built and tested that meets the design goal of approximately 200 {micro}W per channel power consumption with a noise occupancy of less than one hit per trigger per 10,000 channels. Detailed design of the full-scale tracker is well advanced, with non-flight prototypes built for all components, and a complete 50,000 channel engineering demonstration tower module is currently under construction and will be tested in particle beams in late 1999. The flight-instrument conceptual design is for a 4 x 4 array of tower modules with an aperture of 2.9 m{sup 2} and an effective area of greater than 8000 cm{sup 2}.

  5. Credit BG. Test Stand "D" tower as seen looking northeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. Test Stand "D" tower as seen looking northeast (See caption for CA-163-F-18). To the right of the view is the stainless steel dome top for Dv Cell (see CA-163-F-22 for view into cell), behind which rests a spherical accumulator--an electrically heated steam generator for powering the vacuum system at "C" and Test Stand "D." Part of the ejector system can be seen on the right corner of the tower, other connections include electrical ducts (thin, flat metal members) and fire protection systems. Note the stand in the foreground with lights used to indicate safety status of the stand during tests - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  6. Economic and technical assessment of the desiccant wheel effect on the thermal performance of cross flow cooling towers in variable wet bulb temperature

    NASA Astrophysics Data System (ADS)

    Banooni, Salem; Chitsazan, Ali

    2014-05-01

    Performance improvements of cross flow cooling towers in variable wet bulb temperature were performed. A conventional mathematical model is used to predict desiccant wheel effect on the performance of cooling tower. It is found that by using optimum parameters of desiccant wheel, the inlet air wet bulb temperature into the cooling tower would decrease more than 6 °C and outlet water temperature would decrease more than 4 °C.

  7. Optimal Inflatable Space Towers of High Height

    NASA Astrophysics Data System (ADS)

    Bolonkin, Alexander

    2002-01-01

    Author provides theory and computations for building inflatable space towers up to a hundred km in height. These towers can be used for tourism; scientific observation of space, earth's surface, weather, top atmosphere, as well as for radio, television, and communication transmissions. These towers can also be used to launch space ships and Earth satellites. These projects are not expensive and do not require rockets. They require thin strong films composed from artificial fibers and fabricated by current industry. Towers can be built using present technology. Towers can be used (for tourism, communication, etc.) during the construction process and provide self-financing for further construction. The tower design does not require work at high altitudes; all construction can be done at the earth's surface. The transport system for this tower consists a small engine (used only for friction compensation) located at the earth's surface. The tower is separated into sections and has special protection mechanism in case of a damage. Problems involving security, control, repair, and stability of the proposed towers are addressed in subsequent publications. The author is prepared to discuss these and other problems with serious organizations desiring to research and develop these projects.

  8. Optimal inflatable space towers of high height

    NASA Astrophysics Data System (ADS)

    Bolonkin, A.

    Author suggested, developed theory, and computed some projects of an optimal inflatable space tower of the heights some hundreds km. These towers can be used for tourism, scientist observation of space, Earth surface, Earth weather, Earth top atmosphere, and for radio, TV, communication transmissions. These towers can be used for launching of the space ships and Earth s atellites. The computed projects not expensive, do not request rockets. They need only in thin strong films composed from the artificial fibers and fabricated by a current industry. Towers can be built by a current technology. Towers can be explored (for tourism, communication, etc.) in a time of the construction process and give a profit, self- financing for further constriction. They can permanent increase their height. The tower design does not request a work at the high altitudes. All construction works will be making at the Earth surface. Author suggests the transport system for this tower of a high capability, which does not request a power energy issue. The small engine (only for a friction compensation) is located at the Earth surface. The tower is separated on sections and has a special protection of a case of a damage. It is considered also the problems of security, control, repair, etc. of the suggested towers. The author has also solved additional problems, which appear in these projects and which can look as difficult for the given proposal and current technology. The author is prepared to discuss the problems with serious organizations, which want to research and develop these projects.

  9. Optical design of airport control tower cabs.

    PubMed

    Carman, P D; Budde, H W

    1980-02-15

    A study has been made of optical aspects of airport control towers as part of a planned general optimization of control towers by Transport Canada. Problems found were reflections, glare, visual obstructions, identification of distant objects, and excessive solar heat. The study makes recommendations on cab shape, tower height, glazing, shades, sunglasses, binoculars, and internal lighting. Proper choice of cab shape (e.g., 30 degrees window inclination and 12-28 sides) provided effective control of reflections. Some plastic shades werefound to increase the risk of eye damage. Two tower cabs incorporating the recommendations have been built and were found to be satisfactory. PMID:20216882

  10. Spray Rolling Aluminum Strip

    SciTech Connect

    Lavernia, E.J.; Delplanque, J-P; McHugh, K.M.

    2006-05-10

    Spray forming is a competitive low-cost alternative to ingot metallurgy for manufacturing ferrous and non-ferrous alloy shapes. It produces materials with a reduced number of processing steps, while maintaining materials properties, with the possibility of near-net-shape manufacturing. However, there are several hurdles to large-scale commercial adoption of spray forming: 1) ensuring strip is consistently flat, 2) eliminating porosity, particularly at the deposit/substrate interface, and 3) improving material yield. Through this program, a new strip/sheet casting process, termed spray rolling, has been developed, which is an innovative manufacturing technique to produce aluminum net-shape products. Spray rolling combines the benefits of twin-roll casting and conventional spray forming, showing a promising potential to overcome the above hurdles associated with spray forming. Spray rolling requires less energy and generates less scrap than conventional processes and, consequently, enables the development of materials with lower environmental impacts in both processing and final products. Spray Rolling was developed as a collaborative project between the University of California-Davis, the Colorado School of Mines, the Idaho National Engineering and Environmental Laboratory, and an industry team. The following objectives of this project were achieved: (1) Demonstration of the feasibility of the spray rolling process at the bench-scale level and evaluation of the materials properties of spray rolled aluminum strip alloys; and (2) Demonstration of 2X scalability of the process and documentation of technical hurdles to further scale up and initiate technology transfer to industry for eventual commercialization of the process.

  11. European Sail Tower SPS concept

    NASA Astrophysics Data System (ADS)

    Seboldt, W.; Klimke, M.; Leipold, M.; Hanowski, N.

    2001-03-01

    Based on a DLR-study in 1998/99 on behalf of ESA/ESTEC called "System Concepts, Architectures and Technologies for Space Exploration and Utilization (SE&U)" a new design for an Earth-orbiting Solar Power Satellite (SPS) has been developed. The design is called "European Sail Tower SPS" and consists mainly of deployable sail-like structures derived from the ongoing DLR/ESA solar sail technology development activity. Such a SPS satellite features an extremely light-weight and large tower-like orbital system and could supply Europe with significant amounts of electrical power generated by photovoltaic cells and subsequently transmitted to Earth via microwaves. In order to build up the sail tower, 60 units - each consisting of a pair of square-shaped sails - are moved from LEO to GEO with electric propulsion and successively assembled in GEO robotically on a central strut. Each single sail has dimensions of 150m × 150 m and is automatically deployed, using four diagonal light-weight carbon fiber (CFRP) booms which are initially rolled up on a central hub. The electric thrusters for the transport to GEO could also be used for orbit and attitude control of the assembled tower which has a total length of about 15 km and would be mainly gravity gradient stabilized. Employing thin film solar cell technology, each sail is used as a solar array and produces an electric power in orbit of about 3.7 MW e. A microwave antenna with a diameter of 1 km transmits the power to a 10 km rectenna on the ground. The total mass of this 450 MW SPS is about 2100 tons. First estimates indicate that the costs for one kWh delivered in this way could compete with present day energy costs, if launch costs would decrease by two orders of magnitude. Furthermore, mass production and large numbers of installed SPS systems must be assumed in order to lower significantly the production costs and to reduce the influence of the expensive technology development. The paper presents the technical concept

  12. Drop Tower and Aircraft Capabilities

    NASA Technical Reports Server (NTRS)

    Urban, David L.

    2015-01-01

    This presentation is a brief introduction to existing capabilities in drop towers and low-gravity aircraft that will be presented as part of a Symposium: Microgravity Platforms Other Than the ISS, From Users to Suppliers which will be a half day program to bring together the international community of gravity-dependent scientists, program officials and technologists with the suppliers of low gravity platforms (current and future) to focus on the future requirements and use of platforms other than the International Space Station (ISS).

  13. Use of treated gasification wastewater in a pilot cooling tower. Phase I. Final report for the period ending January 31, 1984

    SciTech Connect

    Willson, W.G.; Hendrikson, J.G.; Mann, M.D.; Galegher, S.J.; Gallagher, J.R.; Mayer, G.G.; Thomas, W.C.; Winton, S.L.; Nelson, D.F.

    1984-05-16

    During the UNDERC cooling tower tests, data were colleced and evaluated in five major areas: characterization of cooling tower streams, process performance, biofouling, corrosion, and inorganic/organic fouling. A summary of the results and conclusions for each area is presented. Recommendations are provided for research and development programs to further define the pretreatment and operating requirements for the use of wastewater as cooling tower makeup. The results of the Phase I-Pilot Cooling Tower test have revealed several potential problems that may arise from the use of a relatively high organic content gas liquor as cooling tower makeup. Most of the problems identified are related to the presence of organics in the wastewater which promote biofouling/fouling, corrosion, and emissions from the cooling tower. The Phase II-Pilot Cooling Tower Test will address this issue by identifying the advantages of further treatment of stripped gas liquor to reduce the organic content to a lower level before use in the cooling tower. This test will parallel the Phase I test using the same system and monitoring procedures. Comparison of the results of Phase I and Phase II tests will provide an indication of how well problem areas can be avoided with additional makeup water pretreatment. 39 references, 34 tables, and 25 figures.

  14. Paresev on Taxi Strip

    NASA Technical Reports Server (NTRS)

    1962-01-01

    Test pilot Milton Thompson sitting in NASA Flight Research Center-built Paresev 1 (Paraglider Research Vehicle) on the taxi strip in front of the NASA Flight Research Center in 1962. In this photo the control stick can be seen coming from overhead and hanging in front of the pilot. The control system was a direct link with the wing membrane made of doped Irish linen. By maintaining simplicity during construction, it was possible to make control and configuration changes overnight and, in many instances, in minutes.

  15. About NICADD extruded scintillating strips

    SciTech Connect

    Dyshkant, A.; Beznosko, D.; Blazey, G.; Chakraborty, D.; Francis, K.; Kubik, D.; Lima, J.G.; Rykalin, V.; Zutshi, v.; Baldina, E.; Bross, A.; Deering, P.; Nebel, T.; Pla-Dalmau, A.; Schellpfeffer, J.; Serritella, C.; Zimmerman, J.; /Fermilab

    2005-04-01

    The results of control measurements of extruded scintillating strip responses to a radioactive source Sr-90 are provided, and details of strip choice, preparation, and method of measurement are included. About four hundred one meter long extruded scintillating strips were measured at four different points. These results were essential for prototyping a tail catcher and muon tracker for a future international electron positron linear collider detector.

  16. Spiral Galaxies Stripped Bare

    NASA Astrophysics Data System (ADS)

    2010-10-01

    Six spectacular spiral galaxies are seen in a clear new light in images from ESO's Very Large Telescope (VLT) at the Paranal Observatory in Chile. The pictures were taken in infrared light, using the impressive power of the HAWK-I camera, and will help astronomers understand how the remarkable spiral patterns in galaxies form and evolve. HAWK-I [1] is one of the newest and most powerful cameras on ESO's Very Large Telescope (VLT). It is sensitive to infrared light, which means that much of the obscuring dust in the galaxies' spiral arms becomes transparent to its detectors. Compared to the earlier, and still much-used, VLT infrared camera ISAAC, HAWK-I has sixteen times as many pixels to cover a much larger area of sky in one shot and, by using newer technology than ISAAC, it has a greater sensitivity to faint infrared radiation [2]. Because HAWK-I can study galaxies stripped bare of the confusing effects of dust and glowing gas it is ideal for studying the vast numbers of stars that make up spiral arms. The six galaxies are part of a study of spiral structure led by Preben Grosbøl at ESO. These data were acquired to help understand the complex and subtle ways in which the stars in these systems form into such perfect spiral patterns. The first image shows NGC 5247, a spiral galaxy dominated by two huge arms, located 60-70 million light-years away. The galaxy lies face-on towards Earth, thus providing an excellent view of its pinwheel structure. It lies in the zodiacal constellation of Virgo (the Maiden). The galaxy in the second image is Messier 100, also known as NGC 4321, which was discovered in the 18th century. It is a fine example of a "grand design" spiral galaxy - a class of galaxies with very prominent and well-defined spiral arms. About 55 million light-years from Earth, Messier 100 is part of the Virgo Cluster of galaxies and lies in the constellation of Coma Berenices (Berenice's Hair, named after the ancient Egyptian queen Berenice II). The third

  17. Effects of Airport Tower Controller Decision Support Tool on Controllers Head-Up Time

    NASA Technical Reports Server (NTRS)

    Hayashi, Miwa; Cruz Lopez, Jose M.

    2013-01-01

    Despite that aircraft positions and movements can be easily monitored on the radar displays at major airports nowadays, it is still important for the air traffic control tower (ATCT) controllers to look outside the window as much as possible to assure safe operations of traffic management. The present paper investigates whether an introduction of the NASA's proposed Spot and Runway Departure Advisor (SARDA), a decision support tool for the ATCT controller, would increase or decrease the controllers' head-up time. SARDA provides the controller departure-release schedule advisories, i.e., when to release each departure aircraft in order to minimize individual aircraft's fuel consumption on taxiways and simultaneously maximize the overall runway throughput. The SARDA advisories were presented on electronic flight strips (EFS). To investigate effects on the head-up time, a human-in-the-loop simulation experiment with two retired ATCT controller participants was conducted in a high-fidelity ATCT cab simulator with 360-degree computer-generated out-the-window view. Each controller participant wore a wearable video camera on a side of their head with the camera facing forward. The video data were later used to calculate their line of sight at each moment and eventually identify their head-up times. Four sessions were run with the SARDA advisories, and four sessions were run without (baseline). Traffic-load levels were varied in each session. The same set of user interface - EFS and the radar displays - were used in both the advisory and baseline sessions to make them directly comparable. The paper reports the findings and discusses their implications.

  18. Strip casting apparatus and method

    DOEpatents

    Williams, R.S.; Baker, D.F.

    1988-09-20

    Strip casting apparatus including a molten-metal-holding container and a nozzle to deposit molten metal onto a moving chill drum to directly cast continuous metallic strip. The nozzle body includes a slot bounded between a back and a front lip. The slot width exceeds about 20 times the gap distance between the nozzle and the chill drum surface. Preferably, the slot width exceeds 0.5 inch. This method of strip casting minimizes pressure drop, insuring better metal-to-chill-drum contact which promotes heat transfer and results in a better quality metallic strip. 6 figs.

  19. Strip casting apparatus and method

    DOEpatents

    Williams, Robert S.; Baker, Donald F.

    1988-01-01

    Strip casting apparatus including a molten-metal-holding container and a nozzle to deposit molten metal onto a moving chill drum to directly cast continuous metallic strip. The nozzle body includes a slot bounded between a back and a front lip. The slot width exceeds about 20 times the gap distance between the nozzle and the chill drum surface. Preferably, the slot width exceeds 0.5 inch. This method of strip casting minimizes pressure drop, insuring better metal-to-chill-drum contact which promotes heat transfer and results in a better quality metallic strip.

  20. Health-hazard evaluation report HETA 86-045-1681, 101 Marietta Tower Building, Atlanta, Georgia

    SciTech Connect

    Salisbury, S.; Roper, P.

    1986-04-01

    A reevaluation of the air quality in the Marietta Tower Building, Atlanta, Georgia was requested by the DHHS Region IV Employee Health and Safety Committee because of worker complaints about sinus problems, eye irritation, and headaches. Air cooling and circulation units were inspected on six floors. Outside air supply to these floors was measured and the buildup of carbon dioxide determined as an indicator of indoor pollution.

  1. Wind turbine tower for storing hydrogen and energy

    DOEpatents

    Fingersh, Lee Jay

    2008-12-30

    A wind turbine tower assembly for storing compressed gas such as hydrogen. The tower assembly includes a wind turbine having a rotor, a generator driven by the rotor, and a nacelle housing the generator. The tower assembly includes a foundation and a tubular tower with one end mounted to the foundation and another end attached to the nacelle. The tower includes an in-tower storage configured for storing a pressurized gas and defined at least in part by inner surfaces of the tower wall. In one embodiment, the tower wall is steel and has a circular cross section. The in-tower storage may be defined by first and second end caps welded to the inner surface of the tower wall or by an end cap near the top of the tower and by a sealing element attached to the tower wall adjacent the foundation, with the sealing element abutting the foundation.

  2. 98. SOUTH FRONT OF MODEL. FREESTANDING TOWER TOP AT RIGHT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    98. SOUTH FRONT OF MODEL. FREESTANDING TOWER TOP AT RIGHT REPRESENTED ALTERNATE PROPOSAL FOR NORTH TOWER TO MATCH FLAG TOWER - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  3. DETAIL OF VALVE TOWER SHOWING SLUICE GATE ON EAST SIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF VALVE TOWER SHOWING SLUICE GATE ON EAST SIDE OF TOWER. VIEW FACING WEST - Schofield Barracks Military Reservation, Ku Tree Reservoir, Valve Tower, Kalakoa Stream, East Range, Wahiawa, Honolulu County, HI

  4. 153. Copy of Louis Rosenberg Etching (original in the Tower ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    153. Copy of Louis Rosenberg Etching (original in the Tower City Development Office, Cleveland, Ohio) TERMINAL TOWER UNDER CONSTRUCTION, PUBLIC SQUARE ELEVATION, VIEW NORTHWEST TO SOUTHEAST - Terminal Tower Building, Cleveland Union Terminal, 50 Public Square, Cleveland, Cuyahoga County, OH

  5. 158. Copy of Louis Rosenberg Etching (original in the Tower ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    158. Copy of Louis Rosenberg Etching (original in the Tower City Development Office) TERMINAL TOWER UNDER CONSTRUCTION, PUBLIC SQUARE FACADE, VIEW WEST TO EAST - Terminal Tower Building, Cleveland Union Terminal, 50 Public Square, Cleveland, Cuyahoga County, OH

  6. APPROACH BRIDGE PORTION OF VALVE TOWER FOOT BRIDGE, AS SEEN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    APPROACH BRIDGE PORTION OF VALVE TOWER FOOT BRIDGE, AS SEEN FROM BELOW, SHOWING VALVE TOWER TO RIGHT. VIEW FACING NORTH - Schofield Barracks Military Reservation, Ku Tree Reservoir, Valve Tower Foot Bridge, Kalakoa Stream, East Range, Wahiawa, Honolulu County, HI

  7. Tower Water-Vapor Mixing Ratio

    SciTech Connect

    Guastad, Krista; Riihimaki, Laura; none,

    2013-04-01

    The purpose of the Tower Water-Vapor Mixing Ratio (TWRMR) value-added product (VAP) is to calculate water-vapor mixing ratio at the 25-meter and 60-meter levels of the meteorological tower at the Southern Great Plains (SGP) Central Facility.

  8. COKE QUENCH TOWER EMISSION TESTING PROGRAM

    EPA Science Inventory

    The report gives results of a field study to further define quench tower organic emissions, the character and magnitude of which are virtually unknown. (Limited testing in 1976 indicated that a large quantity of organic material was emitted from quench towers, but these data were...

  9. 76 FR 36983 - Marking Meteorological Evaluation Towers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ... voluntary marking of METs less than 200 feet AGL (76 FR 1326). The FAA agrees that marking these structures... conspicuity of the towers for low level agricultural operations in the vicinity of these towers. FOR FURTHER... operators, associations representing agricultural operators, and state governments concerning the...

  10. Flux Sampling Errors for Aircraft and Towers

    NASA Technical Reports Server (NTRS)

    Mahrt, Larry

    1998-01-01

    Various errors and influences leading to differences between tower- and aircraft-measured fluxes are surveyed. This survey is motivated by reports in the literature that aircraft fluxes are sometimes smaller than tower-measured fluxes. Both tower and aircraft flux errors are larger with surface heterogeneity due to several independent effects. Surface heterogeneity may cause tower flux errors to increase with decreasing wind speed. Techniques to assess flux sampling error are reviewed. Such error estimates suffer various degrees of inapplicability in real geophysical time series due to nonstationarity of tower time series (or inhomogeneity of aircraft data). A new measure for nonstationarity is developed that eliminates assumptions on the form of the nonstationarity inherent in previous methods. When this nonstationarity measure becomes large, the surface energy imbalance increases sharply. Finally, strategies for obtaining adequate flux sampling using repeated aircraft passes and grid patterns are outlined.

  11. Carbon Nanotube Tower-Based Supercapacitor

    NASA Technical Reports Server (NTRS)

    Meyyappan, Meyya (Inventor)

    2012-01-01

    A supercapacitor system, including (i) first and second, spaced apart planar collectors, (ii) first and second arrays of multi-wall carbon nanotube (MWCNT) towers or single wall carbon nanotube (SWCNT) towers, serving as electrodes, that extend between the first and second collectors where the nanotube towers are grown directly on the collector surfaces without deposition of a catalyst and without deposition of a binder material on the collector surfaces, and (iii) a porous separator module having a transverse area that is substantially the same as the transverse area of at least one electrode, where (iv) at least one nanotube tower is functionalized to permit or encourage the tower to behave as a hydrophilic structure, with increased surface wettability.

  12. VALVE TOWER FROM HIGH GROUND NEAR APPROACH BRIDGE. VIEW FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VALVE TOWER FROM HIGH GROUND NEAR APPROACH BRIDGE. VIEW FACING NORTHEAST - Schofield Barracks Military Reservation, Ku Tree Reservoir, Valve Tower, Kalakoa Stream, East Range, Wahiawa, Honolulu County, HI

  13. The Tower Shielding Facility: Its glorious past

    SciTech Connect

    Muckenthaler, F.J.

    1997-05-07

    The Tower Shielding Facility (TSF) is the only reactor facility in the US that was designed and built for radiation-shielding studies in which both the reactor source and shield samples could be raised into the air to allow measurements to be made without interference from ground scattering or other spurious effects. The TSF proved its usefulness as many different programs were successfully completed. It became active in work for the Defense Atomic Support Agency (DASA) Space Nuclear Auxiliary Power, Defense Nuclear Agency, Liquid Metal Fast Breeder Reactor Program, the Gas-Cooled and High-Temperature Gas-Cooled Reactor programs, and the Japanese-American Shielding Program of Experimental Research, just to mention a few of the more extensive ones. The history of the TSF as presented in this report describes the various experiments that were performed using the different reactors. The experiments are categorized as to the programs which they supported and placed in corresponding chapters. The experiments are described in modest detail, along with their purpose when appropriate. Discussion of the results is minimal, but references are given to more extensive topical reports.

  14. Cooling towers for combined cycles: New developments to meet environmental requirements

    NASA Astrophysics Data System (ADS)

    Vouche, M.; Bouton, F.; Lemmens, P.

    Two new developments in dry cooling systems are presented: the single row condenser (SRC) finned tube and the natural draft air-cooled condenser (NDC). The SRC tube is a flat finned tube based on a technology used for compact heat exchangers. This tube was specifically developed for vacuum air-cooled condensers. The serpentine fins of the SRC tube could be made in aluminum or in galvanized steel. The special technique of the brazing of the aluminum fins is described. A technical and economical comparison is made between the classical dry cooling equipment and the NDC. This comparison concludes with the high economic interest in combining the NDC and the single row design. The mechanical draught wet cooling towers with plume abatement are introduced and compared to classical parallel hybrid and reduced plume towers. The environmental impact of wet cooling towers is discussed with regard to heat and mass transfer, plume, bulkiness, and noise.

  15. The Solar lake/condensation tower system (SL/CT System)

    SciTech Connect

    deLangen, L.H.

    1983-08-01

    The system is basically an ammonia cycle between the hot water of a lake, covered with floating heat collectors and the cold air at great height of the atmosphere, only attainable by a high tower. Below, ammonia is evaporated by the water of the lake; at high level, air-cooled condensers take care of the condensation of the ammonia vapour. The system offers a possibility to be combined with a multi-stage sea-water distillation plant, enabling irrigation of deserts and steppes. In the paper attention is given to the design of the tower. Results of calculations are given about attainable energy production, quantities of building materials needed to build the tower and installations, the surface of the lake, the quantities of produced water and the surface of irrigated land.

  16. Three years of vertically resolved CO2/CH4/CO measurements at the tallest tower in the Amazon - Amazonian Tall Tower Observatory (ATTO, Brazil)

    NASA Astrophysics Data System (ADS)

    Valentin Lavrič, Jošt; Winderlich, Jan; Walter, David; Chi, Xuguang; Andreae, Meinrat O.; Heimann, Martin

    2015-04-01

    The 330 m-tall tower that is currently in its final phase of construction at the Amazonian Tall Tower Observatory (ATTO, Brazil; 2° 08'S, 59° 00'W), is the counterpart of the 304 m-tall tower of the Zotino Tall Tower Observatory tower (ZOTTO), located in central Siberia (Russia; 60° 48'N, 89° 21'E). The ATTO tall tower will extend above the atmospheric surface layer and the nocturnal stable boundary layer, and aims at delivering ground breaking findings that will be the basis for improved climate models. While awaiting the completion of the tall tower, a number of campaign or continuous pilot measurements are taking place on the ATTO site at and around the currently tallest Amazonian tower and mast (80 m a.g.l.). Since March 2012, we run continuous high precision CO2/CH4/CO measurements in an air-conditioned container at the foot of the 80 m tower. The sample air inlets are installed at five levels; 79, 53, 38, 24, and 4 m a.g.l. Two frequently calibrated CRDS analyzers (G1301 and G1302; Picarro Inc., USA) are used for measuring CO2/CH4 and CO/CO2, respectively. Even if due to proximity of our measurements to the canopy (~ 35 m a.g.l.) the data is influenced by local sources and sinks, it still provides a valuable insight into the diurnal and seasonal variations of the measured gas species. Additionally, the data set has proven to be also interesting combined with the parameters that are measured by other groups at the site in parallel either continuously or during intensive observation periods (e.g. VOCs, reactive trace gases, aerosols). A first analysis of the available data is presented. Our work was performed within the frame of the German-Brazilian project ATTO and supported by the federal government agencies BMBF and MCT (Grant number BMBF 01LB1001A). We acknowledge the fundamental support by the Max Planck Society, INPA and UEA. Special thanks go to the Amazonas State SDS/CEUC-RDS Uatumã.

  17. Microtube Strip Heat Exchanger

    SciTech Connect

    Doty, F.D.

    1990-12-27

    Doty Scientific (DSI) believes their Microtube-Strip Heat Exchanger will contribute significantly to (a) the closed Brayton cycles being pursued at MIT, NASA, and elsewhere; (b) reverse Brayton cycle cryocoolers, currently being investigated by NASA for space missions, being applied to MRI superconducting magnets; and (c) high-efficiency cryogenic gas separation schemes for CO{sub 2} removal from exhaust stacks. The goal of this current study is to show the potential for substantial progress in high-effectiveness, low-cost, gas-to-gas heat exchangers for diverse applications at temperatures from below 100 K to above 1000 K. To date, the highest effectiveness measured is about 98%, and relative pressure drops below 0.1% with a specific conductance of about 45 W/kgK are reported. During the pre-award period DSI built and tested a 3-module heat exchanger bank using 103-tube microtube strip (MTS) modules. To add to their analytical capabilities, DSI has acquired computational fluid dynamics (CFD) software. This report describes the pre-award work and the status of the ten tasks of the current project, which are: analyze flow distribution and thermal stresses within individual modules; design a heat exchanger bank of ten modules with 400 microtube per module; obtain production quality tubestrip die and AISI 304 tubestrips; obtain production quality microtubing; construct revised MTS heat exchanger; construct dies and fixtures for prototype heat exchanger; construct 100 MTS modules; assemble 8-10 prototype MTS heat exchangers; test prototype MTS heat exchanger; and verify test through independent means. 7 refs., 9 figs. 1 tab. (CK)

  18. Bismuth-based electrochemical stripping analysis

    DOEpatents

    Wang, Joseph

    2004-01-27

    Method and apparatus for trace metal detection and analysis using bismuth-coated electrodes and electrochemical stripping analysis. Both anodic stripping voltammetry and adsorptive stripping analysis may be employed.

  19. Kinetic Space Towers and Launchers

    NASA Astrophysics Data System (ADS)

    Bolonkin, A.

    The paper discusses a new revolutionary method for access to outer space. A cable stands up vertically and pulls up its payload to space with a maximum force determined by its strength. From the ground the cable is allowed to rise up to the required altitude. After this, one can climb to an altitude by this cable or deliver to altitude a required load. The paper shows this is possible and does not infringe on the law of gravity. The article contains the theory of the method and the computations for four projects for towers that are 4, 75, 225 and 160,000 km in height. The first three projects use conventional artificial fiber widely produced by current industry, while the fourth project uses nanotubes made in scientific laboratories. The paper also shows in a fifth project how this idea can be used to launch a load at high altitude.

  20. Tall Tower Wind Energy Monitoring and Numerical Model Validation in Northern Nevada

    SciTech Connect

    Koracin, D.; Kaplan, M.; Smith, C.; McCurdy, G.; Wolf, A.; McCord, T.; King, K.; Belu, R.; Horvath, K.

    2015-10-01

    The main objectives of this project were to conduct a tall-tower and sodar field campaign in complex terrain, investigate wind properties relevant to wind energy assessment, and evaluate high-resolution models with fixed and adaptive grid structures. Two 60-m towers at Virginia Peak ridges near Washoe Valley, Nevada, were instrumented with cup and vane anemometers as well as sonic anemometers, and an acoustic sounder (hereafter sodar) was installed near one of the towers. The towers were located 2,700 m apart with a vertical distance of 140 m elevation between their bases. Each tower had a downhill exposure of rolling complex terrain, with the nearby valley floor 3,200 m to the west and 800 m below the summit. Cup anemometers were installed at both towers at 20, 40, and 60 m, wind vanes at 20 and 60 m, and sonic anemometers at 20 and 60 m. The sodar measurements were nominally provided every 10 m in vertical distance from 40 to 200 m with the quality of the data generally decreasing with height. Surface air temperature, atmospheric pressure, and radiation measurements were conducted at 1.5 m AGL at both of the towers. Although the plan was to conduct a 1-year period of data collection, we extended the period (October 5, 2012 through February 24, 2014) to cover for possible data loss from instrument or communication problems. We also present a preliminary analysis of the towers and sodar data, including a detailed inventory of available and missing data as well as outliers. The analysis additionally includes calculation of the Weibull parameters, turbulence intensity, and initial computation of wind power density at various heights.

  1. Static and Motion-Based Visual Features Used by Airport Tower Controllers: Some Implications for the Design of Remote or Virtual Towers

    NASA Technical Reports Server (NTRS)

    Ellis, Stephen R.; Liston, Dorion B.

    2011-01-01

    Visual motion and other visual cues are used by tower controllers to provide important support for their control tasks at and near airports. These cues are particularly important for anticipated separation. Some of them, which we call visual features, have been identified from structured interviews and discussions with 24 active air traffic controllers or supervisors. The visual information that these features provide has been analyzed with respect to possible ways it could be presented at a remote tower that does not allow a direct view of the airport. Two types of remote towers are possible. One could be based on a plan-view, map-like computer-generated display of the airport and its immediate surroundings. An alternative would present a composite perspective view of the airport and its surroundings, possibly provided by an array of radially mounted cameras positioned at the airport in lieu of a tower. An initial more detailed analyses of one of the specific landing cues identified by the controllers, landing deceleration, is provided as a basis for evaluating how controllers might detect and use it. Understanding other such cues will help identify the information that may be degraded or lost in a remote or virtual tower not located at the airport. Some initial suggestions how some of the lost visual information may be presented in displays are mentioned. Many of the cues considered involve visual motion, though some important static cues are also discussed.

  2. Blasting response of the Eiffel Tower

    NASA Astrophysics Data System (ADS)

    Horlyck, Lachlan; Hayes, Kieran; Caetano, Ryan; Tahmasebinia, Faham; Ansourian, Peter; Alonso-Marroquin, Fernando

    2016-08-01

    A finite element model of the Eiffel Tower was constructed using Strand7 software. The model replicates the existing tower, with dimensions justified through the use of original design drawings. A static and dynamic analysis was conducted to determine the actions of the tower under permanent, imposed and wind loadings, as well as under blast pressure loads and earthquake loads due to an explosion. It was observed that the tower utilises the full axial capacity of individual members by acting as a `truss of trusses'. As such, permanent and imposed loads are efficiently transferred to the primary columns through compression, while wind loads induce tensile forces in the windward legs and compressive forces in the leeward. Under blast loading, the tower experienced both ground vibrations and blast pressures. Ground vibrations induced a negligibly small earthquake loading into the structure which was ignored in subsequent analyses. The blast pressure was significant, and a dynamic analysis of this revealed that further research is required into the damping qualities of the structure due to soil and mechanical properties. In the worst case scenario, the blast was assumed to completely destroy several members in the adjacent leg. Despite this weakened condition, it was observed that the tower would still be able to sustain static loads, at least for enough time for occupant evacuation. Further, an optimised design revealed the structure was structurally sound under a 46% reduction of the metal tower's mass.

  3. Range gated strip proximity sensor

    DOEpatents

    McEwan, T.E.

    1996-12-03

    A range gated strip proximity sensor uses one set of sensor electronics and a distributed antenna or strip which extends along the perimeter to be sensed. A micro-power RF transmitter is coupled to the first end of the strip and transmits a sequence of RF pulses on the strip to produce a sensor field along the strip. A receiver is coupled to the second end of the strip, and generates a field reference signal in response to the sequence of pulse on the line combined with received electromagnetic energy from reflections in the field. The sensor signals comprise pulses of radio frequency signals having a duration of less than 10 nanoseconds, and a pulse repetition rate on the order of 1 to 10 MegaHertz or less. The duration of the radio frequency pulses is adjusted to control the range of the sensor. An RF detector feeds a filter capacitor in response to received pulses on the strip line to produce a field reference signal representing the average amplitude of the received pulses. When a received pulse is mixed with a received echo, the mixing causes a fluctuation in the amplitude of the field reference signal, providing a range-limited Doppler type signature of a field disturbance. 6 figs.

  4. Range gated strip proximity sensor

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    A range gated strip proximity sensor uses one set of sensor electronics and a distributed antenna or strip which extends along the perimeter to be sensed. A micro-power RF transmitter is coupled to the first end of the strip and transmits a sequence of RF pulses on the strip to produce a sensor field along the strip. A receiver is coupled to the second end of the strip, and generates a field reference signal in response to the sequence of pulse on the line combined with received electromagnetic energy from reflections in the field. The sensor signals comprise pulses of radio frequency signals having a duration of less than 10 nanoseconds, and a pulse repetition rate on the order of 1 to 10 MegaHertz or less. The duration of the radio frequency pulses is adjusted to control the range of the sensor. An RF detector feeds a filter capacitor in response to received pulses on the strip line to produce a field reference signal representing the average amplitude of the received pulses. When a received pulse is mixed with a received echo, the mixing causes a fluctuation in the amplitude of the field reference signal, providing a range-limited Doppler type signature of a field disturbance.

  5. First Results From GLAST-LAT Integrated Towers Cosmic Ray Data Taking And Monte Carlo Comparison

    SciTech Connect

    Brigida, M.; Caliandro, A.; Favuzzi, C.; Fusco, P.; Gargano, F.; Giordano, F.; Giglietto, N.; Loparco, F.; Marangelli, B.; Mazziotta, M.N.; Mirizzi, N.; Raino, S.; Spinelli, P.; /Bari U. /INFN, Bari

    2007-02-15

    GLAST Large Area Telescope (LAT) is a gamma ray telescope instrumented with silicon-strip detector planes and sheets of converter, followed by a calorimeter (CAL) and surrounded by an anticoincidence system (ACD). This instrument is sensitive to gamma rays in the energy range between 20 MeV and 300 GeV. At present, the first towers have been integrated and pre-launch data taking with cosmic ray muons is being performed. The results from the data analysis carried out during LAT integration will be discussed and a comparison with the predictions from the Monte Carlo simulation will be shown.

  6. "Tower, Am I Cleared to Land?": Problematic Communication in Aviation Discourse

    ERIC Educational Resources Information Center

    Howard, John W., III

    2008-01-01

    This study examined problematic communication in pilot-air traffic controller (ATC) interaction. More than 15 hours of pilot-ATC dialogue were collected by monitoring control tower frequencies at 15 U.S. airports. The transcribed data yielded a total of 34 ATCs, 270 pilots, and 1,799 turns of talk. Analyses revealed that (a) communication…

  7. EVALUATING THE COSTS OF PACKED-TOWER AERATION AND GAC FOR CONTROLLING SELECTED ORGANICS

    EPA Science Inventory

    This article focuses on a preliminary cost analysis that compares liquid-phase granular activated carbon (GAC) treatment with packed-tower aeration (PTA) treatment, with and without air emissions control. The sensitivity of cost to design and operating variables is also discussed...

  8. Analysis/design of strip reinforced random composites /strip hybrids/

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.; Sinclair, J. H.

    1978-01-01

    Results are described which were obtained by applying advanced analysis methods and composite mechanics to a strip-reinforced random composite square panel with fixed ends. This was done in order to illustrate the use of these methods for the apriori assessment of the composite panel when subjected to complex loading conditions. The panel was assumed to be of E-Glass/Random Composite. The strips were assumed to be of three advanced unidirectional composites to cover a range of low, intermediate, and high modulus stiffness. The panels were assumed to be subjected to complex loadings to assess their adequacy as load-carrying members in auto body, aircraft engine nacelle, and windmill blade applications. The results show that strip hybrid panels can be several times more structurally efficient than the random composite base materials. Some of the results are presented in graphical form and procedures are described for use of these graphs as guides for preliminary design of strip hybrids.

  9. Analysis/design of strip reinforced random composites (strip hybrids)

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.; Sinclair, J. H.

    1978-01-01

    Advanced analysis methods and composite mechanics were applied to a strip-reinforced random composite square panel with fixed ends to illustrate the use of these methods for the a priori assessment of the composite panel when subjected to complex loading conditions. The panel was assumed to be of E-glass random composite. The strips were assumed to be of three advanced unidirectional composites to cover a range of low, intermediate, and high modulus stiffness. The panels were assumed to be subjected to complex loadings to assess their adequacy as load-carrying members in auto body, aircraft engine nacelle and windmill blade applications. The results show that strip hybrid panels can be several times more structurally efficient than the random composite base materials. Some of the results are presented in graphical form and procedures are described for use of these graphs as guides for preliminary design of strip hybrids.

  10. Improvement to Air2Air Technology to Reduce Fresh-Water Evaporative Cooling Loss at Coal-Based Thermoelectric Power Plants

    SciTech Connect

    Ken Mortensen

    2011-12-31

    This program was undertaken to enhance the manufacturability, constructability, and cost of the Air2Air{TM} Water Conservation and Plume Abatement Cooling Tower, giving a validated cost basis and capability. Air2Air{TM} water conservation technology recovers a portion of the traditional cooling tower evaporate. The Condensing Module provides an air-to-air heat exchanger above the wet fill media, extracting the heat from the hot saturated moist air leaving in the cooling tower and condensing water. The rate of evaporate water recovery is typically 10% - 25% annually, depending on the cooling tower location (climate). This program improved the efficiency and cost of the Air2Air{TM} Water Conservation Cooling Tower capability, and led to the first commercial sale of the product, as described.

  11. A comment on towers for windmills. [structural and economic criteria

    NASA Technical Reports Server (NTRS)

    Budgen, H. P.

    1973-01-01

    Design considerations for windmill tower structures include the effects of normal wind forces on the rotor and on the tower. Circular tabular or masonry towers present a relatively simple aerodynamic solution. Economic factors establish the tubular tower as superior for small and medium sized windmills. Concrete and standard concrete block designs are cheaper than refabricated steel structures that have to be freighted.

  12. 5. View of south tower, facing northnortheast from south bank ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. View of south tower, facing north-northeast from south bank of the Columbia River. Center tower and north tower in background, lower right. - Pasco-Kennewick Transmission Line, Columbia River Crossing Towers, Columbia Drive & Gum Street, Kennewick, Benton County, WA

  13. Rebuild cooling tower after partial collapse

    SciTech Connect

    Michell, F.L.; Demjanenko, W.

    1995-07-01

    When this tower suddenly went down, it forced the associated powerplant out of service. To restore operation required a quick assessment of the damage and fast action to reconstruct the tower. The partial collapse and prompt rebuild of a cooling tower at Columbus Southern Co`s Conesville station Unit 4 is a story of what can go wrong and what can be done to set matters right -- in a hurry. The utility is one of seven operating companies in American Electric Power Co`s system. Unit 4 is jointly owned with Cincinnati Gas and Electric Co and Dayton Power and Light Co. The 780-MW coal-fired unit`s closed-loop cooling-water system is served by two double-flow, seven-cell, mechanical-draft cooling towers (4A and 4B). The design basis calls for operating all 14 cells to maintain full load in the summer months.

  14. Using ozone to treat cooling tower water

    SciTech Connect

    Webster, L.

    1995-07-01

    Ozone is a controversial but promising alternative to chemicals for treating water in cooling towers. A powerful disinfectant, ozone can prevent biofouling of heat exchange surfaces, and may mitigate scale and corrosion. Ozone treatment of cooling towers can cut costs for energy, water, sewage, and regulatory compliance. Ozone treatment is an electrotechnology, but ozone equipment represents only a small electric load. Although ozone has provided excellent results in some cooling tower applications, its effectiveness has not been proven conclusively. Less than 1,000 cooling towers use ozone water treatment in the United States. Acceptance of this technology is increasing, however, as indicated by its use by such large firms as IBM, AT and T, DuPont, and Xerox, and by its adoption by some chemical water treatment suppliers. The energy efficiency implications of ozone treatment are being researched. Southern California Edison found that in some systems, ozone treatment improved chiller efficiency up to 20 percent due to cleaner heat exchange surfaces.

  15. Critical point wetting drop tower experiment

    NASA Technical Reports Server (NTRS)

    Kaukler, W. F.; Tcherneshoff, L. M.; Straits, S. R.

    1984-01-01

    Preliminary results for the Critical Point Wetting CPW Drop Tower Experiment are produced with immiscible systems. Much of the observed phenomena conformed to the anticipated behavior. More drops will be needed to test the CPW theory with these immiscible systems.

  16. Ozone inhibits corrosion in cooling towers

    NASA Technical Reports Server (NTRS)

    French, K. R.; Howe, R. D.; Humphrey, M. F.

    1980-01-01

    Commercially available corona discharge ozone generator, fitted onto industrial cooling tower, significantly reduces formation of scales (calcium carbonate) and corrosion. System also controls growth of algae and other microorganisms. Modification lowers cost and improves life of cooling system.

  17. In-well vapor stripping drilling and characterization work plan

    SciTech Connect

    Koegler, K.J.

    1994-03-13

    This work plan provides the information necessary for drilling, sampling, and hydrologic testing of wells to be completed in support of a demonstration of the in-well vapor stripping system. The in-well vapor stripping system is a remediation technology designed to preferentially extract volatile organic compounds (VOCs) from contaminated groundwater by converting them to a vapor phase. Air-lift pumping is used to lift and aerate groundwater within the well. The volatiles escaping the aerated water are drawn off by a slight vacuum and treated at the surface while the water is allowed to infiltrate the vadose zone back to the watertable.

  18. Aerodynamic tower shake force analysis for VAWT

    SciTech Connect

    Loth, J.L.

    1985-02-01

    Vertical axis wind turbines (VAWT) are subjected to blade lift forces which vary continuously in both magnitude and direction. These blade lift forces are transmitted via the blade support arms to the tower. The resulting tower force vector is a composite of: a downwind and a crosswind average force component, rotating force vectors, and force vectors oscillating in the crosswind direction. The frequency of the rotating and oscillating forces are multiples of the product of Bw, where B is the number of blades used and ..omega.. is the rotor angular velocity. The magnitude of the largest tower shake force vector is of the same order as the average downwind force component, and may represent a serious design constraint in the calculation of the required tower stiffness. A closed-form solution for the tower force vectors has been derived, by introducing a suitable wind interference model. It shows that the magnitude of the largest tower shake force vector, using a threebladed rotor, is four times smaller than a two-bladed rotor. The Betz limit and the optimum tip speed ratio as a function of solidity has been derived by comparison with two semicylindrical actuators in series.

  19. Rock Creek Tower Painting Project : Environmental Assessment.

    SciTech Connect

    United States. Bonneville Power Administration.

    1988-10-01

    Bonneville Power Administration (BPA) built a 500-kV line across Rock Creek, a Class I trout stream about 20 miles east of Missoula, MT. Two 190-foot towers rise on either side of the Rock Creek valley, and the line between is suspended 600 feet over the valley floor. The crossing poses a hazard to passing airplanes and disrupts the natural landscape. The area where the line crosses Rock Creek is prized for its scenic beauty. In response to public demand that BPA protect the visual beauty of this area, BPA painted the towers gray to blend them best in with their natural surroundings. The issue now is to decide between either two gray towers or two orange-and-white towers. The underlying need is to resolve the conflict of pilot safety against scenic intrusion. The proposed action is to paint the gray tower aeronautical orange and white. Alternatives are to paint the orange-and-white tower back to its original gray; or leave the dilemma unresolved (the ''no-action'' alternative). 9 refs., 3 figs.

  20. The Dark Side of the Moebius Strip.

    ERIC Educational Resources Information Center

    Schwarz, Gideon E.

    1990-01-01

    Discussed are various models proposed for the Moebius strip. Included are a discussion of a smooth flat model and two smooth flat algebraic models, some results concerning the shortest Moebius strip, the Moebius strip of least elastic energy, and some observations on real-world Moebius strips. (KR)

  1. Sex and stripping

    PubMed Central

    Pellecchia, Marco; Grève, Pierre; Daffonchio, Daniele; Bandi, Claudio; Alma, Alberto

    2010-01-01

    Wolbachia pipientis is known to infect only arthropods and nematodes (mainly filarial worms). A unique feature shared by the two Phyla is the ability to replace the exoskeleton, a process known as ecdysis. This shared characteristic is thought to reflect a common ancestry. Arthropod moulting is induced by the steroid hormone 20-hydroxyecdysone (20E) and a role for ecdysteroids in nematode ecdysis has also been suggested. Removing Wolbachia from filarial worms impairs the host’s development. From analyses of the genome of Wolbachia harbored by the filarial nematode Brugia malayi and that of its host, the bacterium may provide a source of heme, an essential component of cytochrome P450’s that are necessary for steroid hormone biosynthetic pathways. In arthropods, Wolbachia is a reproductive manipulator, inducing various phenotypic effects that may be due to differences in host physiology, in particular, endocrine-related processes governing development and reproduction. Insect steroids have well-defined roles in the coordination of multiple developmental processes, and in adults they control important aspects of reproduction, including ovarian development, oogenesis, sexual behavior, and in some taxa vitellogenin biosynthesis. According to some authors ecdysteroids may also act as sex hormones. In insects sex differentiation is generally thought to be a strictly genetic process, in which each cell decides its own sexual fate based on its sex chromosome constitution, but, surprisingly, recent data demonstrate that in Drosophila sex determination is not cell-autonomous, as it happens in mammals. Thus the presence of signals coordinating the development of a gender-specific phenotype cannot be excluded. This could explain why Wolbachia interferes with insect reproduction; and also could explain why Wolbachia interferes with insect development. Thus, is “sex (=reproduction) and stripping (=ecdysis)” the key to the intimate relationship between Wolbachia and its

  2. Strip casting with fluxing agent applied to casting roll

    DOEpatents

    Williams, Robert S.; O'Malley, Ronald J.; Sussman, Richard C.

    1997-01-01

    A strip caster (10) for producing a continuous strip (24) includes a tundish (12) for containing a melt (14), a pair of horizontally disposed water cooled casting rolls (22) and devices (29) for electrostatically coating the outer peripheral chill surfaces (44) of the casting rolls with a powder flux material (56). The casting rolls are juxtaposed relative to one another for forming a pouting basin (18) for receiving the melt through a teeming tube (16) thereby establishing a meniscus (20) between the rolls for forming the strip. The melt is protected from the outside air by a non-oxidizing gas passed through a supply line (28) to a sealing chamber (26). A preferred flux is boron oxide having a melting point of about 550.degree. C. The flux coating enhances wetting of the steel melt to the casting roll and dissolves any metal oxide formed on the roll.

  3. Strip casting with fluxing agent applied to casting roll

    DOEpatents

    Williams, R.S.; O`Malley, R.J.; Sussman, R.C.

    1997-07-29

    A strip caster for producing a continuous strip includes a tundish for containing a melt, a pair of horizontally disposed water cooled casting rolls and devices for electrostatically coating the outer peripheral chill surfaces of the casting rolls with a powder flux material. The casting rolls are juxtaposed relative to one another for forming a pouting basin for receiving the melt through a teeming tube thereby establishing a meniscus between the rolls for forming the strip. The melt is protected from the outside air by a non-oxidizing gas passed through a supply line to a sealing chamber. A preferred flux is boron oxide having a melting point of about 550 C. The flux coating enhances wetting of the steel melt to the casting roll and dissolves any metal oxide formed on the roll. 3 figs.

  4. Concentration, serotypic profiles, and infectivity of Legionnaires' Disease bacteria populations in cooling towers

    SciTech Connect

    Tyndall, R.L.

    1982-01-01

    At the Philadelphia American Legion Convention in 1976 nearly two hundred people developed pulmonary infection. Of these, twenty-eight died. The causative bacterial agent was subsequently isolated and identified as a previously undiscovered human pathogen, that is, Legionnaires' Disease Bacterium (LDB). Currently it is estimated that over one hundred thousand cases of Legionella occur annually. Cooling towers have been shown to be the source of LDB in some of the outbreaks. Ecological information indicates that the bacteria are present in many natural waters. Moreover, there is strong evidence that algal products can stimulate the growth of LDB. Because cooling tower environments may be conducive for growth and/or dispersal of LDB, a survey of both industrial and air-conditioning cooling towers for the presence of LDB was undertaken.

  5. Assessing the environmental health relevance of cooling towers--a systematic review of legionellosis outbreaks.

    PubMed

    Walser, Sandra M; Gerstner, Doris G; Brenner, Bernhard; Höller, Christiane; Liebl, Bernhard; Herr, Caroline E W

    2014-03-01

    Bioaerosols from cooling towers are often suspected to cause community-acquired legionellosis outbreaks. Although Legionella infections can mostly be assigned to the emission sources, uncertainty exists about the release and distribution into the air, the occurrence of the respirable virulent form and the level of the infective concentration. Our study aimed to evaluate studies on legionellosis outbreaks attributed to cooling towers published within the last 11 years by means of a systematic review of the literature. 19 legionellosis outbreaks were identified affecting 12 countries. Recurring events were observed in Spain and Great Britain. In total, 1609 confirmed cases of legionellosis and a case-fatality rate of approximately 6% were reported. Duration of outbreaks was 65 days on average. For diagnosis the urinary antigen test was mainly used. Age, smoking, male sex and underlying diseases (diabetes, immunodeficiency) could be confirmed as risk factors. Smoking and underlying diseases were the most frequent risk factors associated with legionellosis in 11 and 10 of the 19 studies, respectively. The meteorological conditions varied strongly. Several studies reported a temporal association of outbreaks with inadequate maintenance of the cooling systems. A match of clinical and environmental isolates by serotyping and/or molecular subtyping could be confirmed in 84% of outbreaks. Legionella-contaminated cooling towers as environmental trigger, in particular in the neighbourhood of susceptible individuals, can cause severe health problems and even death. To prevent and control Legionella contamination of cooling towers, maintenance actions should focus on low-emission cleaning procedures of cooling towers combined with control measurements of water and air samples. Procedures allowing rapid detection and risk assessment in the case of outbreaks are essential for adequate public health measures. Systematic registration of cooling towers will facilitate the

  6. Summary of tower designs for large horizontal axis wind turbines

    NASA Technical Reports Server (NTRS)

    Frederick, G. R.; Savino, J. M.

    1986-01-01

    Towers for large horizontal axis wind turbines, machines with a rotor axis height above 30 meters and rated at more than 500 kW, have varied in configuration, materials of construction, type of construction, height, and stiffness. For example, the U.S. large HAWTs have utilized steel truss type towers and free-standing steel cylindrical towers. In Europe, the trend has been to use only free-standing and guyed cylindrical towers, but both steel and reinforced concrete have been used as materials of construction. These variations in materials of construction and type of construction reflect different engineering approaches to the design of cost effective towers for large HAWTs. Tower designs are the NASA/DOE Mod-5B presently being fabricated. Design goals and requirements that influence tower configuration, height and materials are discussed. In particular, experiences with United States large wind turbine towers are elucidated. Finally, current trends in tower designs for large HAWTs are highlighted.

  7. The Drop Tower Bremen -An Overview

    NASA Astrophysics Data System (ADS)

    von Kampen, Peter; Könemann, Thorben; Rath, Hans J.

    The Center of Applied Space Technology and Microgravity (ZARM) was founded in 1985 as an institute of the University of Bremen, which focuses on research on gravitational and space-related phenomena. In 1988, the construction of ZARM`s drop tower began. Since its inau-guration in September 1990, the eye-catching Drop Tower Bremen with a height of 146m and its characteristic glass roof has become twice a landmark on the campus of the University of Bremen and the emblem of the technology park Bremen. As such an outstanding symbol of space science in Bremen the drop tower provides an european unique facility for experiments under conditions of high-quality weightlessness with residual gravitational accelerations in the microgravity regime. The period of maximum 4.74s of each freely falling experiment at the Drop Tower Bremen is only limited by the height of the drop tower vacuum tube, which was fully manufactured of steal and enclosed by an outer concrete shell. Thus, the pure free fall height of each microgravity drop experiment is approximately 110m. By using the later in-stalled catapult system established in 2004 ZARM`s short-term microgravity laboratory is able to nearly double the time of free fall. This world-wide inimitable capsule catapult system meets scientists` demand of extending the period of weightlessness. During the catapult operation the experiment capsule performs a vertical parabolic flight within the drop tower vacuum tube. In this way the time of microgravity can be extended to slightly over 9s. Either in the drop or in the catapult operation routine the repetition rates of microgravity experiments at ZARM`s drop tower facility are the same, generally up to 3 times per day. In comparison to orbital platforms the ground-based laboratory Drop Tower Bremen represents an economic alternative with a permanent access to weightlessness on earth. Moreover, the exceptional high quality of weightlessness in order of 1e-6 g (in the frequency range below 100

  8. Salt water cooling tower retrofit experience

    SciTech Connect

    Rittenhouse, R.C.

    1994-06-01

    This article describes the experience of engineers at Atlantic Electric Co. with a recent cooling tower fill retrofit at the company's B.L. England Station, Unit 3. Note that this tower is unique. It is the first natural draft salt water tower to be built in the United States. Unit 3's closed-loop saltwater cooling system features a double condenser and two 50% capacity horizontal circulating water pumps. A natural draft cooling tower rejects heat to the atmosphere through evaporation and sensible heat transfer. The tower is 180 ft in diameter at the base and 208 ft high, and features a counterflow design. It was designed to cool 63,500 gpm of circulating salt water through a range of 26 F with an approach of 19.2 degrees at an ambient wet bulb temperature of 76 F and 60% relative humidity. A drift rate of 0.002% of circulating water flow was specified to avoid excessive salt water carryover.

  9. Mycobacteria in Finnish cooling tower waters.

    PubMed

    Torvinen, Eila; Suomalainen, Sini; Paulin, Lars; Kusnetsov, Jaana

    2014-04-01

    Evaporative cooling towers are water systems used in, e.g., industry and telecommunication to remove excess heat by evaporation of water. Temperatures of cooling waters are usually optimal for mesophilic microbial growth and cooling towers may liberate massive amounts of bacterial aerosols. Outbreaks of legionellosis associated with cooling towers have been known since the 1980's, but occurrences of other potentially pathogenic bacteria in cooling waters are mostly unknown. We examined the occurrence of mycobacteria, which are common bacteria in different water systems and may cause pulmonary and other soft tissue infections, in cooling waters containing different numbers of legionellae. Mycobacteria were isolated from all twelve cooling systems and from 92% of the 24 samples studied. Their numbers in the positive samples varied from 10 to 7.3 × 10(4) cfu/L. The isolated species included M. chelonae/abscessus, M. fortuitum, M. mucogenicum, M. peregrinum, M. intracellulare, M. lentiflavum, M. avium/nebraskense/scrofulaceum and many non-pathogenic species. The numbers of mycobacteria correlated negatively with the numbers of legionellae and the concentration of copper. The results show that cooling towers are suitable environments for potentially pathogenic mycobacteria. Further transmission of mycobacteria from the towers to the environment needs examination. PMID:23937212

  10. Intrabeam stripping in H- Linacs

    SciTech Connect

    Lebedev, V.; Solyak, N.; Ostigy, J.-F.; Alexandrov, A.; Shishlo, A.; /Oak Ridge

    2010-09-01

    A beam loss in the superconducting part of the SNS linac has been observed during its commissioning and operation. Although the loss does not prevent the SNS high power operation, it results in an almost uniform irradiation of linac components and increased radiation levels in the tunnel. Multi-particle tracking could neither account for the magnitude of the observed loss nor its dependence on machine parameters. It was recently found that the loss is consistent with the intrabeam particle collisions resulting in stripping of H{sup -} ions. The paper describes experimental observations and corresponding analytical estimates of the intrabeam stripping.

  11. The design of solar tower power plants

    NASA Astrophysics Data System (ADS)

    Gretz, J.

    The conversion of solar energy into electricity in solar thermal tower power plants is examined. Mirrors attached to mobile, sun-following heliostats concentrate solar rays into the opening of a receiver mounted on a tower. In the receiver, the radiant energy is absorbed by a system of pipes filled with a flowing material which is heated and drives a turbogenerator directly or via a heat exchanger. It is shown that the optics involved in this concept preclude the optimization of the pipe material, since the local distribution of rays in the heater of tower power plants varies diurnally and annually. This requires each pipe section to be designed for maximum stress, even though that stress occurs only at brief intervals during the day.

  12. Simple model of a cooling tower plume

    NASA Astrophysics Data System (ADS)

    Jan, Cizek; Jiri, Nozicka

    2016-06-01

    This article discusses the possibilities in the area of modeling of the so called cooling tower plume emergent at operating evaporating cooling systems. As opposed to recent publication, this text focuses on the possibilities of a simplified analytic description of the whole problem where this description shall - in the future - form the base of a calculation algorithms enabling to simulate the efficiency of systems reducing this cooling tower plume. The procedure is based on the application of basic formula for the calculation of the velocity and concentration fields in the area above the cooling tower. These calculation is then used to determine the form and the total volume of the plume. Although this approach does not offer more exact results, it can provide a basic understanding of the impact of individual quantities relating to this problem.

  13. Cooling tower water conditioning study. [using ozone

    NASA Technical Reports Server (NTRS)

    Humphrey, M. F.; French, K. R.

    1979-01-01

    Successful elimination of cooling tower treatment chemicals was demonstrated. Three towers functioned for long periods of time with ozone as the only treatment for the water. The water in the systems was reused as much as 30 times (cycles of concentration) without deleterious effects to the heat exchangers. Actual system blow-down was eliminated and the only makeup water added was that required to replace the evaporation and mist entrainment losses. Minimum water savings alone are approximately 75.1 1/kg/year. Cost estimates indicate that a savings of 55 percent was obtained on the systems using ozone. A major problem experienced in the use of ozone for cooling tower applications was the difficulty of accurate concentration measurements. The ability to control the operational characteristics relies on easily and accurately determined concentration levels. Present methods of detection are subject to inaccuracies because of interfering materials and the rapid destruction of the ozone.

  14. Analyzing the possibility of achieving more efficient cooling of water in the evaporative cooling towers of the Armenian NPP

    NASA Astrophysics Data System (ADS)

    Petrosyan, V. G.; Yeghoyan, E. A.

    2015-10-01

    The specific features of the service cooling water system used at the Armenian NPP and modifications made in the arrangement for supplying water to the water coolers in order to achieve more efficient cooling are presented. The mathematical model applied in carrying out the analyses is described, the use of which makes it possible to investigate the operation of parallel-connected cooling towers having different hydraulic and thermal loads. When the third standby cooling tower is put into operation (with the same flow rate of water supplied to the water coolers), the cooled water temperature is decreased by around 2-3°C in the range of atmospheric air temperatures 0-35°C. However, the introduced water distribution arrangement with a decreased spraying density has limitation on its use at negative outdoor air temperatures due to the hazard intense freezing of the fill in the cooling tower peripheral zone. The availability of standby cooling towers in the shutdown Armenian NPP power unit along with the planned full replacement of the cooling tower process equipment create good possibilities for achieving a deeper water cooling extent and better efficiency of the NPP. The present work was carried out with the aim of achieving maximally efficient use of existing possibilities and for elaborating the optimal cooling tower modernization version. Individual specific heat-andmass transfer processes in the chimney-type evaporative cooling towers are analyzed. An improved arrangement for distributing cooled water over the cooling tower spraying area (during its operation with a decreased flow rate) is proposed with the aim of cooling water to a deeper extent and preserving the possibility of using the cooling towers in winter. The main idea behind improving the existing arrangement is to exclude certain zones of the cooling tower featuring inefficient cooling from operation. The effectiveness of introducing the proposed design is proven by calculations (taking as an

  15. Characteristics of laminates with delamination control strips

    NASA Technical Reports Server (NTRS)

    Sun, C. T.; Goering, J. C.; Alper, J. M.; Gause, L. W.

    1992-01-01

    Tough resin is needed to resist delamination crack propagation. However, modulus often has to be compromised because it is difficult to retain both high modulus and toughness in a matrix material. A potential solution is to use a hybrid system in which tough resin strips are included within a conventional matrix composite. By adjusting the spacing of the tough resin strips, maximum delamination size can be controlled. Experimental results for impact damage and subsequent damage propagation in laminates containing tough resin strips are reported. Plain adhesive strips and fiber-reinforced tough resin composite strips were used in constructing the hybrid laminates. Test results indicated that size of delamination inflicted by impact was confined between the tough resin strips. As a result, significantly increased residual compressive strength was obtained. Impacted laminates containing tough resin strips were also fatigue tested. It was found that these strips reduced the growth of the impact damage area relative to the growth seen in coupons with no tough resin strips. Damage growth from an open hole under tension fatigue was evaluated using both tough resin strips and glass fiber reinforced tough resin strips. Unreinforced tough resin strips retarded delamination growth from the open hole, but did not stop matrix cracks growing in the fiber direction. Fiber reinforced tough resin strips did not contain axial delamination growth from the open hole. However, they did act as crack arresters, stopping the through-the-thickness tension crack originating from the hole.

  16. Characteristics of laminates with delamination control strips

    SciTech Connect

    Sun, C.T.; Goering, J.C.; Alper, J.M.; Gause, L.W.

    1992-09-01

    Tough resin is needed to resist delamination crack propagation. However, modulus often has to be compromised because it is difficult to retain both high modulus and toughness in a matrix material. A potential solution is to use a hybrid system in which tough resin strips are included within a conventional matrix composite. By adjusting the spacing of the tough resin strips, maximum delamination size can be controlled. Experimental results for impact damage and subsequent damage propagation in laminates containing tough resin strips are reported. Plain adhesive strips and fiber-reinforced tough resin composite strips were used in constructing the hybrid laminates. Test results indicated that size of delamination inflicted by impact was confined between the tough resin strips. As a result, significantly increased residual compressive strength was obtained. Impacted laminates containing tough resin strips were also fatigue tested. It was found that these strips reduced the growth of the impact damage area relative to the growth seen in coupons with no tough resin strips. Damage growth from an open hole under tension fatigue was evaluated using both tough resin strips and glass fiber reinforced tough resin strips. Unreinforced tough resin strips retarded delamination growth from the open hole, but did not stop matrix cracks growing in the fiber direction. Fiber reinforced tough resin strips did not contain axial delamination growth from the open hole. However, they did act as crack arresters, stopping the through-the-thickness tension crack originating from the hole.

  17. Drop Tower Facility at Queensland University of Technology

    NASA Astrophysics Data System (ADS)

    Plagens, Owen; Castillo, Martin; Steinberg, Theodore; Ong, Teng-Cheong

    The Queensland University of Technology (QUT) Drop Tower Facility is a {raise.17exscriptstyle˜}2.1 second, 21.3 m fall, dual capsule drop tower system. The dual capsule comprises of an uncoupled exterior hollow drag shield that experiences drag by the ambient atmosphere with the experimental capsule falling within the drag shield. The dual capsule system is lifted to the top of the drop tower via a mechanical crane and the dropping process is initiated by the cutting of a wire coupling the experimental package and suspending the drag shield. The internal experimental capsule reaches the bottom of the drag shield floor just prior to the deceleration stage at the air bag and during this time experience gravity levels of {raise.17exscriptstyle˜}10textsuperscript{-6} g. The deceleration system utilizes an inflatable airbag where experimental packages can be designed to experience a maximum deceleration of {raise.17exscriptstyle˜}10textsuperscript{18} g for {raise.17exscriptstyle˜}0.1 seconds. The drag shield can house experimental packages with a maximum diameter of 0.8 m and height of 0.9 m. The drag shield can also be used in foam mode, where the walls are lined with foam and small experiments can be dropped completely untethered. This mode is generally used for the study of microsatellite manipulation. Payloads can be powered by on-board power systems with power delivered to the experiment until free fall occurs. Experimental data that can be collected includes but is not limited to video, temperature, pressure, voltage/current from the power supply, and triggering mechanisms outputs which are simultaneously collected via data logging systems and high speed video recording systems. Academic and commercial projects are currently under investigation at the QUT Drop Tower Facility and collaboration is openly welcome at this facility. Current research includes the study of heterogeneously burning metals in oxygen which is aimed at fire safety applications and

  18. CFD MODELING AND ANALYSIS FOR A-AREA AND H-AREA COOLING TOWERS

    SciTech Connect

    Lee, S.; Garrett, A.; Bollinger, J.

    2009-09-02

    Mechanical draft cooling towers are designed to cool process water via sensible and latent heat transfer to air. Heat and mass transfer take place simultaneously. Heat is transferred as sensible heat due to the temperature difference between liquid and gas phases, and as the latent heat of the water as it evaporates. Mass of water vapor is transferred due to the difference between the vapor pressure at the air-liquid interface and the partial pressure of water vapor in the bulk of the air. Equations to govern these phenomena are discussed here. The governing equations are solved by taking a computational fluid dynamics (CFD) approach. The purpose of the work is to develop a three-dimensional CFD model to evaluate the flow patterns inside the cooling tower cell driven by cooling fan and wind, considering the cooling fans to be on or off. Two types of the cooling towers are considered here. One is cross-flow type cooling tower located in A-Area, and the other is counterflow type cooling tower located in H-Area. The cooling tower located in A-Area is mechanical draft cooling tower (MDCT) consisting of four compartment cells as shown in Fig. 1. It is 13.7m wide, 36.8m long, and 9.4m high. Each cell has its own cooling fan and shroud without any flow communications between two adjacent cells. There are water distribution decks on both sides of the fan shroud. The deck floor has an array of about 25mm size holes through which water droplet falls into the cell region cooled by the ambient air driven by fan and wind, and it is eventually collected in basin area. As shown in Fig. 1, about 0.15-m thick drift eliminator allows ambient air to be humidified through the evaporative cooling process without entrainment of water droplets into the shroud exit. The H-Area cooling tower is about 7.3 m wide, 29.3 m long, and 9.0 m high. Each cell has its own cooling fan and shroud, but each of two corner cells has two panels to shield wind at the bottom of the cells. There is some

  19. 2. Slacking Tower south side, view to the northnortheast. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Slacking Tower south side, view to the north-northeast. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Slacking Tower, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT

  20. 1. Keeper's house and light tower, view north, south and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Keeper's house and light tower, view north, south and east sides of keeper's house, southwest and southeast sides of tower - Whitehead Light Station, Whitehead Island, East northeast of Tenants Harbor, Spruce Head, Knox County, ME

  1. 2. Light tower, keeper's house and shed, view south southwest, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Light tower, keeper's house and shed, view south southwest, northwest and northeast sides of tower, east and north sides of keeper's house and shed - Whitehead Light Station, Whitehead Island, East northeast of Tenants Harbor, Spruce Head, Knox County, ME

  2. 1. Keeper's house and light tower, view northwest, south and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Keeper's house and light tower, view northwest, south and east sides of keeper's house, southwest and southeast sides of light tower - Curtis Island Light Station, Curtis Island, at entrance to Camden Harbor, Camden, Knox County, ME

  3. Lifting system and apparatus for constructing wind turbine towers

    DOEpatents

    Livingston, Tracy; Schrader, Terry; Goldhardt, James; Lott, James

    2011-02-01

    The disclosed invention is utilized for mounting a wind turbine and blade assembly on the upper end of a wind turbine tower. The invention generally includes a frame or truss that is pivotally secured to the top bay assembly of the tower. A transverse beam is connected to the frame or truss and extends fore of the tower when the frame or truss is in a first position and generally above the tower when in a second position. When in the first position, a wind turbine or blade assembly can be hoisted to the top of the tower. The wind turbine or blade assembly is then moved into position for mounting to the tower as the frame or truss is pivoted to a second position. When the turbine and blade assembly are secured to the tower, the frame or truss is disconnected from the tower and lowered to the ground.

  4. Steam sand dryer in northeast part of sand tower. View ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Steam sand dryer in northeast part of sand tower. View to northeast - Duluth & Iron Range Rail Road Company Shops, Sand Tower, Southwest of downtown Two Harbors, northwest of Agate Bay, Two Harbors, Lake County, MN

  5. 2. Detail of tower foundation with lightning transfer wire, southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Detail of tower foundation with lightning transfer wire, southeast corner - Cold Mountain Fire Lookout Station, Lookout Tower, Krassel District, Frank Church River of No Return Wilderness, Dixie, Idaho County, ID

  6. Interior of the mine observation tower building, showing the steel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior of the mine observation tower building, showing the steel compass ring in the tower. View facing east - U.S. Naval Base, Pearl Harbor, Waipio Peninsula, Waipo Peninsula, Pearl City, Honolulu County, HI

  7. 14. CLOSEUP VIEW OF WINDOW IN SIGNAL TOWER OFFICE FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. CLOSE-UP VIEW OF WINDOW IN SIGNAL TOWER OFFICE FACING WEST. - U.S. Naval Base, Pearl Harbor, Signal Tower, Corner of Seventh Street & Avenue D east of Drydock No. 1, Pearl City, Honolulu County, HI

  8. 4. VIEW, LOOKING SOUTHEAST, SHOWING NORTHWEST ELEVATION OF TOWER ND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW, LOOKING SOUTHEAST, SHOWING NORTHWEST ELEVATION OF TOWER ND SIGNAL BRIDGE No. 6 AND DWARF SIGNAL IN FOREGROUND - South Station Tower No. 1 & Interlocking System, Dewey Square, Boston, Suffolk County, MA

  9. 1. View of north tower, facing northwest from dike on ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. View of north tower, facing northwest from dike on north bank of the Columbia River. - Pasco-Kennewick Transmission Line, Columbia River Crossing Towers, Columbia Drive & Gum Street, Kennewick, Benton County, WA

  10. TOWER, WEST ELEVATION, SHOWING CONNECTION PIPES FOR TURNOUTS 22 (FOREGROUND) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    TOWER, WEST ELEVATION, SHOWING CONNECTION PIPES FOR TURNOUTS 22 (FOREGROUND) AND 24. NOTE “LAZY JACK” TEMPERATURE COMPENSATOR IN FOREGROUND. - Baltimore & Ohio Railroad, Z Tower, State Route 46, Keyser, Mineral County, WV

  11. 29. Photocopy of 1921 photograph. Glass Negative Box IX, Tower ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. Photocopy of 1921 photograph. Glass Negative Box IX, Tower Grove, Missouri Botanical Garden. ITALIAN GARDEN AND NEW PALM HOUSE (DEMOLISHED), LOOKING NORTHEAST - Missouri Botanical Garden, 2345 Tower Grove Avenue, Saint Louis, Independent City, MO

  12. 5. Detail of tower bottom step and stairway structure, facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Detail of tower bottom step and stairway structure, facing southeast - Cold Mountain Fire Lookout Station, Lookout Tower, Krassel District, Frank Church River of No Return Wilderness, Dixie, Idaho County, ID

  13. 1. View of tower with cabin in the right foreground, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. View of tower with cabin in the right foreground, facing southeast - Cold Mountain Fire Lookout Station, Lookout Tower, Krassel District, Frank Church River of No Return Wilderness, Dixie, Idaho County, ID

  14. OVERVIEW OF VALVE TOWER FROM NORTHERN SIDE OF BASIN. VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    OVERVIEW OF VALVE TOWER FROM NORTHERN SIDE OF BASIN. VIEW FACING SOUTHWEST - Schofield Barracks Military Reservation, Ku Tree Reservoir, Valve Tower, Kalakoa Stream, East Range, Wahiawa, Honolulu County, HI

  15. OVERVIEW OF VALVE TOWER FROM EASTERN SIDE OF BASIN SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    OVERVIEW OF VALVE TOWER FROM EASTERN SIDE OF BASIN SHOWING BRIDGE SUPPORTS ON HILLTOP. VIEW FACING WEST - Schofield Barracks Military Reservation, Ku Tree Reservoir, Valve Tower, Kalakoa Stream, East Range, Wahiawa, Honolulu County, HI

  16. View of the campanile and southeast tower looking from the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of the campanile and southeast tower looking from the south tower roof (duplicate of HABS No. DC-141-40) - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  17. 1. VIEW NORTHWEST, operations building, height finder radar tower, and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW NORTHWEST, operations building, height finder radar tower, and radar tower (unknown function) - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI

  18. 50. NORTHERN VIEW OF NONEVAPORATIVE WASTE WATER TREATMENT COOLING TOWERS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. NORTHERN VIEW OF NON-EVAPORATIVE WASTE WATER TREATMENT COOLING TOWERS IN CENTER, AND EVAPORATIVE WASTE WATER COOLING TOWERS ON RIGHT. (Jet Lowe) - U.S. Steel Duquesne Works, Blast Furnace Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  19. Economic effects of transmission towers on field crops in Ontario

    SciTech Connect

    Scott, W.S.

    1981-03-01

    The effects of various transmission tower sizes and locations on field crops typical to eastern and western Ontario were studied. About 70% of the costs of the towers to farmers was a result of the non-productive area created by the presence of the tower, and the remaining 30% comprised time lost in working around towers, crop damage, and, in some cases, material loss. The best location for towers was observed to be on fence-rows, while towers located in the headland had the greatest impact on operations. The magnitude of the factors involved in the costs to farmers of the presence of transmission towers was related to tower size and location, equipment size, and crop grown.

  20. 2. Light tower and keeper's house, view southwest, north northeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Light tower and keeper's house, view southwest, north northeast side of tower, northeast and northwest sides of keeper's house - Wood Island Light Station, East end of Wood Island, at mouth of Soo River, Biddeford Pool, York County, ME

  1. 1. Keeper's house and light tower, view north northeast, southwest ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Keeper's house and light tower, view north northeast, southwest and southeast sides of house, northwest and southwest sides of tower - Wood Island Light Station, East end of Wood Island, at mouth of Soo River, Biddeford Pool, York County, ME

  2. 26. Evening view of concrete mixing plant, concrete placement tower, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. Evening view of concrete mixing plant, concrete placement tower, cableway tower, power line and derrick. Photographer unknown, 1927. Source: MWD. - Waddell Dam, On Agua Fria River, 35 miles northwest of Phoenix, Phoenix, Maricopa County, AZ

  3. APPROACH BRIDGE PORTION OF VALVE TOWER FOOT BRIDGE, AS SEEN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    APPROACH BRIDGE PORTION OF VALVE TOWER FOOT BRIDGE, AS SEEN FROM ENTRY. VIEW FACING NORTHWEST - Schofield Barracks Military Reservation, Ku Tree Reservoir, Valve Tower Foot Bridge, Kalakoa Stream, East Range, Wahiawa, Honolulu County, HI

  4. 27. STATIC TEST TOWER CLOSEUP VIEW OF CONTROL PANEL AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. STATIC TEST TOWER CLOSE-UP VIEW OF CONTROL PANEL AT REAR OF TOWER UNDER SHED ROOF. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  5. Cell block one and southeast guard tower, looking from the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Cell block one and southeast guard tower, looking from the central guard tower, facing southeast (note view also includes cell block ten (left) and cell block nine (right)) - Eastern State Penitentiary, 2125 Fairmount Avenue, Philadelphia, Philadelphia County, PA

  6. 3. View looking E from top of World Trade Tower ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. View looking E from top of World Trade Tower with World Trade Tower parapet in foreground. Jet Lowe, photographer, 1982. - Brooklyn Bridge, Spanning East River between Park Row, Manhattan and Sands Street, Brooklyn, New York County, NY

  7. View of EPA Farm metal weather tower, facing east, showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of EPA Farm metal weather tower, facing east, showing thirty-acre irrigated field - Nevada Test Site, Environmental Protection Agency Farm, Weather Tower, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  8. BUFFERS AND VEGETATIVE FILTER STRIPS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Buffers and filter strips are areas of permanent vegetation located within and between agricultural fields and the water courses to which they drain. These buffers are intended to intercept and slow runoff thereby providing water quality benefits. In addition, in many settings they are intended to...

  9. The Perils of Strip Searches.

    ERIC Educational Resources Information Center

    Trotter, Andrew

    1995-01-01

    Every year, a few administrators mishandle school searches and create spectacles similar to the New Castle, Pennsylvania, incident involving six illegally strip-searched students. Principals using "cops-and-robber" techniques to unearth contraband may not realize the potential for infringing on students' constitutional privacy rights. Strip…

  10. Low-cost Triangular Lattice Towers for Small Wind Turbines

    NASA Astrophysics Data System (ADS)

    Adhikari, Ram Chandra

    This thesis focuses on the study of low-cost steel and bamboo triangular lattice towers for small wind turbines. The core objective is to determine the material properties of bamboo and assess the feasibility of bamboo towers. Using the experimentally determined buckling resistance, elastic modulus, and Poisson's ratio, a 12 m high triangular lattice tower for a 500W wind turbine has been modeled as a tripod to formulate the analytical solutions for the stresses and tower deflections, which enables design of the tower based on buckling strength of tower legs. The tripod formulation combines the imposed loads, the base distance between the legs and tower height, and cross-sectional dimensions of the tower legs. The tripod model was used as a reference for the initial design of the bamboo tower and extended to finite element analysis. A 12 m high steel lattice tower was also designed for the same turbine to serve as a comparison to the bamboo tower. The primary result of this work indicates that bamboo is a valid structural material. The commercial software package ANSYS APDL was used to carry out the tower analysis, evaluate the validity of the tripod model, and extend the analysis for the tower design. For this purpose, a 12 m high steel lattice tower for a 500 W wind turbine was examined. Comparison of finite element analysis and analytical solution has shown that tripod model can be accurately used in the design of lattice towers. The tower designs were based on the loads and safety requirements of international standard for small wind turbine safety, IEC 61400-2. For connecting the bamboo sections in the lattice tower, a steel-bamboo adhesive joint combined with conventional lashing has been proposed. Also, considering the low durability of bamboo, periodic replacement of tower members has been proposed. The result of this study has established that bamboo could be used to construct cost-effective and lightweight lattice towers for wind turbines of 500 Watt

  11. Bimaterial Thermal Strip With Increased Flexing

    NASA Technical Reports Server (NTRS)

    Morrison, Andrew D.

    1994-01-01

    In proposed bimaterial thermal strip, one layer has negative coefficient of thermal expansion, thereby increasing difference between coefficients of thermal expansion of two outer layers and consequently increasing flexing caused by change in temperature. Proposed bimaterial strips used in thermostats.

  12. TECHNOLOGY ASSESSMENT OF SOIL VAPOR EXTRACTION AND AIR SPARGING

    EPA Science Inventory

    Air sparging, also called "in situ air stripping and in situ volatilization" injects air into the saturated zone to strip away volatile organic compounds (VOCs) dissolved in groundwater and adsorbed to soil. hese volatile contaminants transfer in a vapor phase to the unsaturated ...

  13. Noise determination in silicon micro strips

    SciTech Connect

    Dubbs, T.; Kashigin, S.; Kratzer, M.

    1996-06-01

    The authors report the study of amplifier noise on silicon micro strip detectors. They have used a fast, low noise amplifier-comparator VLSI chip with 22ns shaping time developed for the LHC to determine the noise at the pre-amp as a function of strip length and strip geometry, i.e., interstrip capacitance and ohmic strip resistance. In addition, they have tested the noise in irradiated detectors. They have compared the results with simulations using SPICE.

  14. 1. Slacking Tower north side, view to the southsouthwest. The ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Slacking Tower north side, view to the south-southwest. The tower was used for dredging the river downstream of the powerhouse. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Slacking Tower, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT

  15. 3. View from former light tower to Cape Elizabeth Light ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. View from former light tower to Cape Elizabeth Light Tower, view northeast, southwest side of Cape Elizabeth Tower - Cape Elizabeth Light Station, Near Two Lights State Park at end of Two Lights Road, off State Highway 77, Cape Elizabeth, Cumberland County, ME

  16. DETAIL VIEW OF AERIAL TRAM SUPPORT TOWERS THREE AND FOUR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL VIEW OF AERIAL TRAM SUPPORT TOWERS THREE AND FOUR WITH TOWERS FIVE AND SIX IN THE DISTANCE, LOOKING NORTHEAST. THE TWO INTACT CABLES RUNNING ALONG TOP OF THE TOWERS ARE FIXED. WHILE THE MOVING CABLE IS LYING SLACK ON THE GROUND. - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA

  17. 6. Detail of northeast corner of Shell Interlocking Tower, showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Detail of northeast corner of Shell Interlocking Tower, showing ornamental east concrete beltcourse and tower shield with bronze numerals. - New York, New Haven, & Hartford Railroad, Shell Interlocking Tower, New Haven Milepost 16, approximately 100 feel east of New Rochelle Junction, New Rochelle, Westchester County, NY

  18. 8. VIEW OF THE EAST BASE CONNECTION OF ANTENNA TOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW OF THE EAST BASE CONNECTION OF ANTENNA TOWER S-111 FACING NORTHEAST. BUILDING 1 AND ANTENNA TOWER S-110 IN THE BACKGROUND. - U.S. Naval Base, Pearl Harbor, Lualualei Radio Transmitter, Edison & Tower Drives, Pearl City, Honolulu County, HI

  19. 4. VIEW NORTHEAST, radar tower (unknown function), prime search radar ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW NORTHEAST, radar tower (unknown function), prime search radar tower, emergency power building, and height finder radar tower - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI

  20. 2. VIEW SOUTHWEST, prime search radar tower, height finder radar ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW SOUTHWEST, prime search radar tower, height finder radar towards, height finder radar towers, and radar tower (unknown function) - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI

  1. 36 CFR 7.30 - Devils Tower National Monument.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 1 2013-07-01 2013-07-01 false Devils Tower National... INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.30 Devils Tower National Monument. (a... Devils Tower. The registrant is also required to sign in immediately upon completion of a climb in...

  2. 36 CFR 7.30 - Devils Tower National Monument.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Devils Tower National... INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.30 Devils Tower National Monument. (a... Devils Tower. The registrant is also required to sign in immediately upon completion of a climb in...

  3. 36 CFR 7.30 - Devils Tower National Monument.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 1 2012-07-01 2012-07-01 false Devils Tower National... INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.30 Devils Tower National Monument. (a... Devils Tower. The registrant is also required to sign in immediately upon completion of a climb in...

  4. 36 CFR 7.30 - Devils Tower National Monument.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Devils Tower National... INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.30 Devils Tower National Monument. (a... Devils Tower. The registrant is also required to sign in immediately upon completion of a climb in...

  5. 36 CFR 7.30 - Devils Tower National Monument.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 1 2014-07-01 2014-07-01 false Devils Tower National... INTERIOR SPECIAL REGULATIONS, AREAS OF THE NATIONAL PARK SYSTEM § 7.30 Devils Tower National Monument. (a... Devils Tower. The registrant is also required to sign in immediately upon completion of a climb in...

  6. CONCRETE PAD AND SUSPENSION BRIDGE TOWERS FOR CABLES FORMERLY SUPPORTING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CONCRETE PAD AND SUSPENSION BRIDGE TOWERS FOR CABLES FORMERLY SUPPORTING THE SUSPENSION BRIDGE PORTION OF VALVE TOWER FOOT BRIDGE. VIEW FACING NORTHEAST - Schofield Barracks Military Reservation, Ku Tree Reservoir, Valve Tower Foot Bridge, Kalakoa Stream, East Range, Wahiawa, Honolulu County, HI

  7. The Tower and Glass Marbles Problem

    ERIC Educational Resources Information Center

    Denman, Richard T.; Hailey, David; Rothenberg, Michael

    2010-01-01

    The Catseye Marble company tests the strength of its marbles by dropping them from various levels of their office tower, to find the highest floor from which a marble will not break. We find the smallest number of drops required and from which floor each drop should be made. We also find out how these answers change if a restriction is placed on…

  8. Tower Power: Producing Fuels from Solar Energy

    ERIC Educational Resources Information Center

    Antal, M. J., Jr.

    1976-01-01

    This article examines the use of power tower technologies for the production of synthetic fuels. This process overcomes the limitations of other processes by using a solar furnace to drive endothermic fuel producing reactions and the resulting fuels serve as a medium for storing solar energy. (BT)

  9. Balsa Tower Walls Brave "Big Buster"

    ERIC Educational Resources Information Center

    Granlund, George

    2008-01-01

    Like many technology teachers, the author, a technology education teacher at Arthur Hill High School in Saginaw, Michigan, tries to stretch his budget by "milking" each student activity for maximum benefit. In the technology department, they use balsa wood towers to teach the basics of structural engineering. To get the most from their materials,…

  10. Taking the Plunge off the Ivory Tower.

    ERIC Educational Resources Information Center

    Mauzerall, Jorgette

    1997-01-01

    Relates the experiences of a white academic teaching in a black rural state college--a plunge into the world of black experience which shocked the academic. States that everything was different--students' names, their manner of dress, their reaction to the O.J. Simpson verdict. Finds that leaving the ivory tower was not easy, but the job exceeded…

  11. The Legacy of the Texas Tower Sniper

    ERIC Educational Resources Information Center

    Lavergne, Gary

    2007-01-01

    In this article, the author relates the incident that happened at the University of Texas to the tragedy that took place at Virginia Tech. On August 1, 1966, Charles Joseph Whitman ascended the University of Texas Tower, in Austin, and in 96 minutes fired 150 high-powered rounds of ammunition down upon an unsuspecting university family. The…

  12. The Tower of Hanoi and Inductive Logic

    ERIC Educational Resources Information Center

    Merrotsy, Peter

    2015-01-01

    In the "Australian Curriculum," the concept of mathematical induction is first met in the senior secondary subject Specialist Mathematics. This article details an example, the Tower of Hanoi problem, which provides an enactive introduction to the inductive process before moving to more abstract and cognitively demanding representations.…

  13. 26 CFR 1.1286-1 - Tax treatment of certain stripped bonds and stripped coupons.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... stripped bond or stripped coupon is less than the amount computed under subparagraphs (A) and (B) of...)) shall be considered to be zero. For purposes of this computation, the number of complete years to maturity is measured from the date the stripped bond or stripped coupon is purchased. (b) Treatment...

  14. 26 CFR 1.1286-1 - Tax treatment of certain stripped bonds and stripped coupons.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 11 2012-04-01 2012-04-01 false Tax treatment of certain stripped bonds and stripped coupons. 1.1286-1 Section 1.1286-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE... Gains and Losses § 1.1286-1 Tax treatment of certain stripped bonds and stripped coupons. (a) De...

  15. 26 CFR 1.1286-1 - Tax treatment of certain stripped bonds and stripped coupons.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 11 2014-04-01 2014-04-01 false Tax treatment of certain stripped bonds and stripped coupons. 1.1286-1 Section 1.1286-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE... Gains and Losses § 1.1286-1 Tax treatment of certain stripped bonds and stripped coupons. (a) De...

  16. 26 CFR 1.1286-1 - Tax treatment of certain stripped bonds and stripped coupons.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 11 2013-04-01 2013-04-01 false Tax treatment of certain stripped bonds and stripped coupons. 1.1286-1 Section 1.1286-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE... Gains and Losses § 1.1286-1 Tax treatment of certain stripped bonds and stripped coupons. (a) De...

  17. 7 CFR 29.2304 - Strips.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Strips. 29.2304 Section 29.2304 Agriculture... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2304 Strips... strips....

  18. 7 CFR 29.3551 - Strips.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Strips. 29.3551 Section 29.3551 Agriculture... Type 95) § 29.3551 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  19. 7 CFR 29.3551 - Strips.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Strips. 29.3551 Section 29.3551 Agriculture... Type 95) § 29.3551 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  20. 7 CFR 29.2556 - Strips.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Strips. 29.2556 Section 29.2556 Agriculture...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2556 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  1. 7 CFR 29.6041 - Strips.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Strips. 29.6041 Section 29.6041 Agriculture... INSPECTION Standards Definitions § 29.6041 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  2. 7 CFR 29.6041 - Strips.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Strips. 29.6041 Section 29.6041 Agriculture... INSPECTION Standards Definitions § 29.6041 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  3. 7 CFR 29.1063 - Strips.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Strips. 29.1063 Section 29.1063 Agriculture... Type 92) § 29.1063 Strips. The sides of a tobacco leaf from which the stem has been removed from a lot of tobacco composed of strips....

  4. 7 CFR 29.3062 - Strips.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Strips. 29.3062 Section 29.3062 Agriculture... Strips. The sides of a tobacco leaf from which the stem has been removed; or a lot of tobacco composed of strips....

  5. 7 CFR 29.3062 - Strips.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Strips. 29.3062 Section 29.3062 Agriculture... Strips. The sides of a tobacco leaf from which the stem has been removed; or a lot of tobacco composed of strips....

  6. 7 CFR 29.2304 - Strips.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Strips. 29.2304 Section 29.2304 Agriculture... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2304 Strips... strips....

  7. 7 CFR 29.2556 - Strips.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Strips. 29.2556 Section 29.2556 Agriculture...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2556 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  8. 21 CFR 886.1800 - Schirmer strip.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Schirmer strip. 886.1800 Section 886.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1800 Schirmer strip. (a) Identification. A Schirmer strip is...

  9. 7 CFR 29.2304 - Strips.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strips. 29.2304 Section 29.2304 Agriculture... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2304 Strips... strips....

  10. 7 CFR 29.3551 - Strips.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Strips. 29.3551 Section 29.3551 Agriculture... Type 95) § 29.3551 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  11. 7 CFR 29.6041 - Strips.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Strips. 29.6041 Section 29.6041 Agriculture... INSPECTION Standards Definitions § 29.6041 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  12. 7 CFR 29.1063 - Strips.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Strips. 29.1063 Section 29.1063 Agriculture... Type 92) § 29.1063 Strips. The sides of a tobacco leaf from which the stem has been removed from a lot of tobacco composed of strips....

  13. 21 CFR 886.1800 - Schirmer strip.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Schirmer strip. 886.1800 Section 886.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1800 Schirmer strip. (a) Identification. A Schirmer strip is...

  14. 7 CFR 29.2556 - Strips.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strips. 29.2556 Section 29.2556 Agriculture...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2556 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  15. 7 CFR 29.3551 - Strips.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strips. 29.3551 Section 29.3551 Agriculture... Type 95) § 29.3551 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  16. 7 CFR 29.2304 - Strips.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Strips. 29.2304 Section 29.2304 Agriculture... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2304 Strips... strips....

  17. 7 CFR 29.1063 - Strips.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Strips. 29.1063 Section 29.1063 Agriculture... Type 92) § 29.1063 Strips. The sides of a tobacco leaf from which the stem has been removed from a lot of tobacco composed of strips....

  18. 7 CFR 29.3062 - Strips.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strips. 29.3062 Section 29.3062 Agriculture... Strips. The sides of a tobacco leaf from which the stem has been removed; or a lot of tobacco composed of strips....

  19. 7 CFR 29.1063 - Strips.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Strips. 29.1063 Section 29.1063 Agriculture... Type 92) § 29.1063 Strips. The sides of a tobacco leaf from which the stem has been removed from a lot of tobacco composed of strips....

  20. 7 CFR 29.6041 - Strips.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Strips. 29.6041 Section 29.6041 Agriculture... INSPECTION Standards Definitions § 29.6041 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  1. 7 CFR 29.2556 - Strips.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Strips. 29.2556 Section 29.2556 Agriculture...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2556 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  2. 7 CFR 29.3062 - Strips.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Strips. 29.3062 Section 29.3062 Agriculture... Strips. The sides of a tobacco leaf from which the stem has been removed; or a lot of tobacco composed of strips....

  3. 7 CFR 29.3551 - Strips.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Strips. 29.3551 Section 29.3551 Agriculture... Type 95) § 29.3551 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  4. 21 CFR 886.1800 - Schirmer strip.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Schirmer strip. 886.1800 Section 886.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1800 Schirmer strip. (a) Identification. A Schirmer strip is...

  5. 7 CFR 29.2304 - Strips.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Strips. 29.2304 Section 29.2304 Agriculture... INSPECTION Standards Official Standard Grades for Virginia Fire-Cured Tobacco (u.s. Type 21) § 29.2304 Strips... strips....

  6. 7 CFR 29.6041 - Strips.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strips. 29.6041 Section 29.6041 Agriculture... INSPECTION Standards Definitions § 29.6041 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  7. 7 CFR 29.3062 - Strips.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Strips. 29.3062 Section 29.3062 Agriculture... Strips. The sides of a tobacco leaf from which the stem has been removed; or a lot of tobacco composed of strips....

  8. 7 CFR 29.2556 - Strips.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Strips. 29.2556 Section 29.2556 Agriculture...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2556 Strips. The sides of a tobacco leaf from which the stem has been removed or a lot of tobacco composed of strips....

  9. 7 CFR 29.1063 - Strips.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strips. 29.1063 Section 29.1063 Agriculture... Type 92) § 29.1063 Strips. The sides of a tobacco leaf from which the stem has been removed from a lot of tobacco composed of strips....

  10. Pretreatment of anaerobic digestion effluent with ammonia stripping and biogas purification.

    PubMed

    Lei, Xiaohui; Sugiura, Norio; Feng, Chuanping; Maekawa, Takaaki

    2007-07-16

    In this study, ammonia stripping was optimized for pretreating anaerobic digestion effluent from an anaerobic digestion plant, and the possibility of using CO(2) stripping and biogas injection for adjusting the pH of the effluent before and after the ammonia stripping process was also investigated. For ammonia stripping, the results showed that an overdose of calcium hydroxide, i.e., 27.5g/L wastewater, achieved higher ammonia, phosphorus, chemical oxygen demand, suspended solids, and turbidity removal efficiency. An air flow rate of 5L/min for 1L of wastewater was thought as suitable for engineering application. The pH of the anaerobic digestion effluent can be increased from about 7 to about 9 by CO(2) stripping, however which is insufficient for ammonia stripping. For 1L of wastewater treated after ammonia stripping, the pH can be neutralized to about 7 from greater than 11 through biogas injection at 1L/min for less than 30min, and continuous injection does not decrease the pH. It was roughly estimated that 43m(3) of biogas (CH(4):CO(2) approximately 60%:40%) produced daily could be purified to CH(4):CO(2) approximately 74%:26% by neutralizing the pH of the 5m(3) anaerobic digestion effluent pretreated by ammonia stripping. PMID:17178436

  11. Tall tower or mountain top measurements?

    NASA Astrophysics Data System (ADS)

    Bamberger, Ines; Eugster, Werner; Oney, Brian; Brunner, Dominik; Leuenberger, Markus; Schanda, Rüdiger; Henne, Stephan; Buchmann, Nina

    2014-05-01

    Resolving the regional transport and distribution of greenhouse gases in the troposphere is a key topic that challenges both modelers and experimentalists. A dense network of measurement stations would be required, in particular including measurements at high elevation to better represent the entire lower troposphere, and not only small-scale local conditions in the near-surface atmosphere. While this can be achieved by tall towers, also mountain top stations (e.g. Schauinsland, Brocken) and other stations at high elevation (e.g., Mouna Loa, Jungfraujoch) are often appropriate, due to their extended concentration footprint. However, especially over complex, mountainous terrain, the transport of atmospheric gases and their spatio-temporal distribution is difficult to predict due to the development of thermally induced local wind patterns and boundary layer processes. Therefore, the main goal of our study is to test to what extend boundary layer processes at the surface and local wind patterns close to the ground at a mountain top site influence the ambient greenhouse gas patterns compared to measurements taken at a similar altitude but at a tall tower site. To this end we use measurements from the Zugerberg mountain top station, located at a pre-Alpine mountain ridge (987 m a.s.l., 4 m above ground) exposed to the prevailing synoptic winds in Switzerland, and compare these measurements with a neighboring tall tower site (Beromünster radio broadcast tower with its top at 1014 m a.s.l., 217 m above local ground level, and ≡500 m above the Swiss Plateau). The Beromünster tall tower is located at a distance of only 30 km from the mountain top station as the bird flies, and hence a direct comparison minimizes confounding factors that are not related to the tall tower vs. mountain top position of the measurements. Both stations are part of the CarboCount CH greenhouse gas observation network (http://www.carbocount.ch) initiated for long-term monitoring and modeling of

  12. ETR COOLING TOWER. PUMP HOUSE (TRA645) IN SHADOW OF TOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR COOLING TOWER. PUMP HOUSE (TRA-645) IN SHADOW OF TOWER ON LEFT. AT LEFT OF VIEW, HIGH-BAY BUILDING IS ETR. ONE STORY ATTACHMENT IS ETR ELECTRICAL BUILDING. STACK AT RIGHT IS ETR STACK; MTR STACK IS TOWARD LEFT. CAMERA FACING NORTHEAST. INL NEGATIVE NO. 56-3799. Jack L. Anderson, 11/26/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  13. Analysis of Radiant Cooling System Configurations Integrated with Cooling Tower for Different Indian Climatic Zones

    SciTech Connect

    Mathur, Jyotirmay; Bhandari, Mahabir S; Jain, Robin; Srivastava, Prateek

    2016-01-01

    Radiant cooling system has proven to be a low energy consumption system for building cooling needs. This study describes the use of cooling tower in radiant cooling system to improve the overall system efficiency. A comprehensive simulation feasibility study of the application of cooling tower in radiant cooling system was performed for the fifteen cities in different climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of the different climatic zones except warm-humid is suitable for the integration of cooling tower with radiant cooling system. In these climates, cooling tower can provide on average 24 C to 27 C water In order to achieve the energy saving potential, three different configurations of radiant cooling system have been compared in terms of energy consumption. The different configurations of the radiant cooling system integrated with cooling tower are: (1) provide chilled water to the floor, wall and ceiling mounted tubular installation. (2) provide chilled water to the wall and ceiling mounted tabular installation. In this arrangement a separate chiller has also been used to provide chilled water at 16 C to the floor mounted tubular installation. (3) provide chilled water to the wall mounted tabular installation and a separate chiller is used to provide chilled water at 16 C to the floor and ceiling mounted tabular installation. A dedicated outdoor air system is also coupled for dehumidification and ventilation in all three configurations. A conventional all-air system was simulated as a baseline to compare these configurations for assessing the energy saving potential.

  14. Update on the Purdue University 2-second Drop Tower

    NASA Astrophysics Data System (ADS)

    Collicott, Steven

    an update on progress for the micro-gravity community. The most noticeable current activity is testing of the air-bag decelerator. The tower is one that will use a free-falling experiment inside of a drag shield to avoid most aerodynamic drag. The airbag is designed from experiences of others yet the small, triangular room in which the tower terminates imposes challenges. The airbag is approximately 1.5m diameter and 1.5m tall. Initial testing led to a desire to increase vent area, and just this week the bag has returned from the shop that was modifying it. On-board computer, battery packs, lighting, and cameras have been acquired. Thanks to Lockheed Martin, one camera is 500 frames per second with 1.3 million 12-bit gray scale pixels per frame. The Spincraft company donated steel hemisphere-cylinders to serve as the nose of the drag shield. Wind tunnel and CFD modeling of the drag shield has been performed by Purdue undergraduate aerospace students. Currently the drag shield structure and experiment package structure are being design and analyzed. The experiment volume is approximately a cylinder 0.45m diameter and 0.6m tall. Tower operation is intended to commence in fall 2010 with inert package drops at full mass and full height. Developing the operations procedures, especially operational safety, are the goals of this work. First science is then expected in the winter. References 1. Y. Chen, "A Study of Capillary Flow in a Vane-wall Gap in Zero Gravity," Ph.D. thesis, School of Aeronautics and Astronautics, Purdue University. August 2003. 2. Y. Chen and S. H. Collicott, "Investigation of the Symmetric Wetting of a Vane-Wall Gap in Propellant Tanks," AIAA Journal, 42, No. 2, pp. 305-314, February 2004. 3. Y. Chen, and S. H. Collicott, "Experimental Study on the Capillary Flow in a Vane-Wall Gap Geometry," AIAA Journal, 43, No. 11, pp. 2395-2403, November, 2005. 4. Y. Chen and S. H. Collicott, "Study of Wetting in an Asymmetrical Vane-Wall Gap in Propellant Tanks

  15. Update on the Purdue University 2-second Drop Tower

    NASA Astrophysics Data System (ADS)

    Collicott, Steven

    an update on progress for the micro-gravity community. The most noticeable current activity is testing of the air-bag decelerator. The tower is one that will use a free-falling experiment inside of a drag shield to avoid most aerodynamic drag. The airbag is designed from experiences of others yet the small, triangular room in which the tower terminates imposes challenges. The airbag is approximately 1.5m diameter and 1.5m tall. Initial testing led to a desire to increase vent area, and just this week the bag has returned from the shop that was modifying it. On-board computer, battery packs, lighting, and cameras have been acquired. Thanks to Lockheed Martin, one camera is 500 frames per second with 1.3 million 12-bit gray scale pixels per frame. The Spincraft company donated steel hemisphere-cylinders to serve as the nose of the drag shield. Wind tunnel and CFD modeling of the drag shield has been performed by Purdue undergraduate aerospace students. Currently the drag shield structure and experiment package structure are being design and analyzed. The experiment volume is approximately a cylinder 0.45m diameter and 0.6m tall. Tower operation is intended to commence in fall 2010 with inert package drops at full mass and full height. Developing the operations procedures, especially operational safety, are the goals of this work. First science is then expected in the winter. References 1. Y. Chen, "A Study of Capillary Flow in a Vane-wall Gap in Zero Gravity," Ph.D. thesis, School of Aeronautics and Astronautics, Purdue University. August 2003. 2. Y. Chen and S. H. Collicott, "Investigation of the Symmetric Wetting of a Vane-Wall Gap in Propellant Tanks," AIAA Journal, 42, No. 2, pp. 305-314, February 2004. 3. Y. Chen, and S. H. Collicott, "Experimental Study on the Capillary Flow in a Vane-Wall Gap Geometry," AIAA Journal, 43, No. 11, pp. 2395-2403, November, 2005. 4. Y. Chen and S. H. Collicott, "Study of Wetting in an Asymmetrical Vane-Wall Gap in Propellant Tanks

  16. Calder Hall Cooling Tower Demolition: Landmark Milestone for Decommissioning at Sellafield

    SciTech Connect

    Williamson, E.J.

    2008-07-01

    September 2007 saw a very visible change to the Sellafield site following the culmination of a major decommissioning project; the demolition of the four Calder Hall cooling towers. A key part of the UK's nuclear industrial heritage, Calder Hall, the world's first commercial nuclear power station, was opened by Her Majesty Queen Elizabeth II in October 1953 and continued to generate electricity until its closure in 2003. Following the decision to decommission the Calder Hall site, explosive demolition was identified as the safest and most cost effective route for the removal of the towers. The technique, involving the placement of explosive in 60% of the circumference of both shell and legs, is a tried and tested method which had already been used successfully in more than 200 cooling towers in the UK in the last 30 years. The location and composition of the four 88 metre high towers also created additional challenges. Situated only 40 metres away from the UK's only nuclear Fuel Handling Plant, as well as other sensitive structures on the Sellafield site, the project had to address the impact of a number of key areas, including dust, ground vibration and air over pressure, to ensure that the demolition could be carried out safely and without significant impact on other operational areas on the site. At the same time, the towers had to be prepared for demolition in a way that minimised the amounts of radioactive or hazardous waste materials arising. This paper follows the four year journey from the initial decision to demolish the towers right through to the demolition itself as well as the clean up of the site post demolition. It will also consider the massive programme of work necessary not only to carry out the physical work safely but also to gain regulatory confidence and stakeholder support to carry out the project successfully. In summary: The demolition of the four Calder Hall cooling towers was a highly visible symbol of the changes that are occurring on the

  17. Bonded orthotropic strips with cracks

    NASA Technical Reports Server (NTRS)

    Delale, F.; Erdogan, F.

    1978-01-01

    The elastostatic problem for a nonhomogeneous plane which consists of two sets of periodically arranged dissimilar orthotropic strips is considered. First, the problem of cracks fully imbedded into the homogeneous strips is considered. Then, the singular behavior of the stresses for two special crack geometries is studied in some detail. The first is the case of a broken laminate in which the crack tips touch the interfaces. The second is the case of cracks crossing the interfaces. A number of numerical examples are worked out in order to separate the primary material parameters influencing the stress intensity factors and the powers of stress singularity, and to determine the trends regarding the influence of the secondary parameters. Finally, some numerical results are given for the stress intensity factors in certain basic crack geometries and for typical material combinations.

  18. Antenna structure with distributed strip

    SciTech Connect

    Rodenbeck, Christopher T.

    2008-10-21

    An antenna comprises electrical conductors arranged to form a radiating element including a folded line configuration and a distributed strip configuration, where the radiating element is in proximity to a ground conductor. The folded line and the distributed strip can be electrically interconnected and substantially coplanar. The ground conductor can be spaced from, and coplanar to, the radiating element, or can alternatively lie in a plane set at an angle to the radiating element. Embodiments of the antenna include conductor patterns formed on a printed wiring board, having a ground plane, spacedly adjacent to and coplanar with the radiating element. Other embodiments of the antenna comprise a ground plane and radiating element on opposed sides of a printed wiring board. Other embodiments of the antenna comprise conductors that can be arranged as free standing "foils". Other embodiments include antennas that are encapsulated into a package containing the antenna.

  19. Antenna structure with distributed strip

    SciTech Connect

    Rodenbeck, Christopher T.

    2008-03-18

    An antenna comprises electrical conductors arranged to form a radiating element including a folded line configuration and a distributed strip configuration, where the radiating element is in proximity to a ground conductor. The folded line and the distributed strip can be electrically interconnected and substantially coplanar. The ground conductor can be spaced from, and coplanar to, the radiating element, or can alternatively lie in a plane set at an angle to the radiating element. Embodiments of the antenna include conductor patterns formed on a printed wiring board, having a ground plane, spacedly adjacent to and coplanar with the radiating element. Other embodiments of the antenna comprise a ground plane and radiating element on opposed sides of a printed wiring board. Other embodiments of the antenna comprise conductors that can be arranged as free standing "foils". Other embodiments include antennas that are encapsulated into a package containing the antenna.

  20. ASSESSMENT OF DIOXIN INHALATION EXPOSURES AND POTENTIAL HEALTH IMPACTS FOLLOWING THE COLLAPSE OF THE WORLD TRADE CENTER TOWERS

    EPA Science Inventory

    In the days following the September 11, 2001, terrorist attack on New York City's World Trade Center (WTC) towers, EPA, other federal agencies, and New York City and New York State public health and environmental authorities initiated numerous air monitoring activities to better ...

  1. Roll Casting of Aluminum Alloy Clad Strip

    SciTech Connect

    Nakamura, R.; Tsuge, H.; Haga, T.; Watari, H.; Kumai, S.

    2011-01-17

    Casting of aluminum alloy three layers of clad strip was tried using the two sets of twin roll casters, and effects of the casting parameters on the cladding conditions were investigated. One twin roll caster was mounted on the other twin roll caster. Base strip was 8079 aluminum alloy and overlay strips were 6022 aluminum alloy. Effects of roll-load of upper and lower casters and melt temperature of the lower caster were investigated. When the roll-load of the upper and lower caster was large enough, the overlay strip could be solidified and be connected. The overlay strip could be connected when the melt of the overlay strip cast by the lower caster was low enough. Sound three layers of clad strip could be cast by proper conditions.

  2. Experimental optimization of cooling-tower-fan control based on field data. Master's thesis

    SciTech Connect

    Herman, D.L.

    1991-04-01

    Energy costs continue to play an important role in the decision-making process for building design and operation. Since the chiller, cooling tower fans, and associated pumps consume the largest fraction of energy in a heating, ventilating, and air-conditioning (HVAC) system, the control of these components is of major importance in determining building energy use. A significant control parameter for the chilled water system is the minimum entering condenser water set point temperature at which the cooling tower fans are cycled on and off, several studies have attempted to determine the optimum value for this minimum set point temperature, but direct measurements are not available to validate these studies. The purpose of this study was to experimentally determine the optimum minimum entering condenser water set point temperature from field data based on minimum energy consumption and to validate a chilled water system analytical model previously developed in earlier work. The total chiller system electrical consumption (chiller and cooling tower fan energy) was measured for four entering condensor water set point temperatures (70, 75, 80, and 85 deg F). The field results were compared to results obtained using an analytical model previously developed in a thesis entitled Optimized Design of a Commercial Building Chiller/Cooling Tower System, written by Joyce.

  3. Real world energy performance a look at chiller/cooling tower performance

    SciTech Connect

    Schmitt, R.W.

    1996-12-31

    Traditional selection criteria for chillers has focused on the chiller kW/ton at full-load design conditions, with little or no attention paid to part-load or off-design conditions. This is beginning to change because part-load or off-design conditions account for approximately 98% of chiller operating hours. With a multiple chiller central plant, part-load conditions mean running one or more chillers at or near peak capacity, with the other chillers off. This usually occurs in the fall, winter and spring, or during evening and nighttime hours, when outdoor air temperatures are lower. Consequently, entering condenser water temperatures below design are available. This paper will look at the economies of taking advantage of these conditions, and spend time looking at cooling tower selections. Cooling towers are relatively inexpensive when compared to chillers, and it often makes sense to use a higher capacity tower and lower the design entering condenser water temperature to the chiller. Improved chiller efficiencies will offset the additional tower cost and fan power.

  4. Dynamic analysis of the Milad Tower

    NASA Astrophysics Data System (ADS)

    Wilhelm, Edwin; Ford, Mitchell; Coelho, Darren; Lawler, Lachlan; Ansourian, Peter; Alonso-Marroquin, Fernando; Tahmasebinia, Faham

    2016-08-01

    This report involves the modelling of the Milad Tower using the finite element analysis program Strand7. A dynamic analysis was performed on the structure in order to understand the deflections and stresses as a result of earthquake and wind loading. In particular, Linear Static as well as Natural Frequency and Spectral Response solvers were used to determine the behaviour of the structure under loading. The findings of the report highlight that the structure was modelled accurately with the outputs representing realistic values. The report suggests that the design of the beams, columns, slabs and all structural members was sufficient enough to support the tower during maximum loading cases. The governing load case was earthquake loading.

  5. Buffing, burnishing, and stripping of vinyl asbestos floor tile

    SciTech Connect

    Hollett, B.A.; Edwards, A.; Clark, P.J.

    1995-10-01

    Studies were conducted to evaluate airborne asbestos concentrations during the three principal types of preventative maintenance (low-speed spray-buffing, ultra high-speed burnishing, and wet-stripping) used on asbestos-containing floor tiles. These were done under pre-existing and prepared levels of floor care maintenance. Airborne asbestos concentrations were measured before and during each floor care procedure to determine the magnitude of the increase in airborne asbestos levels during each procedure. Airborne total fiber concentrations were also measured for comparison with the Occupational Safety and Health Administration`s (OSHA) Permissible Exposure Limit (PEL) of 0.1 f/cm{sup 3}. Low-speed spray-buffing and wet-stripping were evaluated on pre-existing floor conditions and three levels of prepared floor care conditions (poor, medium, and good). Ultra high-speed burnishing and wet-stripping were evaluated on two levels of prepared floor care conditions (poor and good). Floor care conditions were defined in consultation with the Chemical Specialty Manufacturers Association and other representatives of floor-care chemical manufacturers. Controlled studies were conducted in an unoccupied building at the decommissioned Chanute Air Force Base in Rantoul, Illinois, with the cooperation of the U.S. Air Force. The building offered approximately 8600 ft{sup 2} of open floor space tiled with 9-inch by 9-inch resilient floor tile containing approximately 5% chrysotile asbestos.

  6. Side Stream Filtration for Cooling Towers

    SciTech Connect

    2012-10-20

    This technology evaluation assesses side stream filtration options for cooling towers, with an objective to assess key attributes that optimize energy and water savings along with providing information on specific technology and implementation options. This information can be used to assist Federal sites to determine which options may be most appropriate for their applications. This evaluation provides an overview of the characterization of side stream filtration technology, describes typical applications, and details specific types of filtration technology.

  7. Aspects of cooling tower biocides and protozoa

    SciTech Connect

    Berk, S.G.; Ashburn, R.J.; Ting, R.S.

    1998-12-31

    Previous work has shown that certain cooling tower amoebae and ciliated protozoa are resistant to several cooling tower biocides, even at the manufacturer`s recommended dosages. For the present study, an Acunthumoeba species was isolated from a cooling tower in Australia. Suspensions of the trophozoites (feeding stages) were exposed to isothiazolones. Cysts were tested separately. The minimum lethal concentration (MLC) for trophozoites was between 31-62 ppm of the biocide product, which is slightly less than the MLC for an amoebae species from the United States; and cyst forms were twofold more resistant than those of the US species, with a MLC of 62,500 ppm. A ciliate and an amoeba species were also exposed to bromochlorodimethylhydantoin. The MLC for the ciliate species was 1 ppm of the biocide product, and the MLC was 30--40 ppm for the amoeba trophozoites. Since amoebae can expel vesicles containing live Legionella, experiments were conducted to determine whether exposure of Acunthamoebu polyphugu to biocides influenced release of such potentially infectious particles. Vesicle release was not inhibited by any of the three biocides: quaternary ammonium compounds (QACs), isothiazolones, and a thiocarbamate compound. These results suggest that amoebae from various sources are resistant to recommended levels of biocides, and the amoebae may continue to release potentially infectious vesicles in the presence of biocides.

  8. Water-conserving cooling tower treatment

    SciTech Connect

    Mathie, A.J.

    1996-12-31

    Water conservation in cooling towers and evaporative coolers can finally become a reality. Also, fouled closed hot and chilled water systems can be restored to near original efficiency using the same technology. The barrier limiting the traditional water treatment industry from serious involvement in water conservation is the lack of a really good chemical to control scale. Poor scale inhibitors are the reason for a heavy bleed. Minerals concentrated by evaporation is wasted to the sewer while low solids make-up water fills the tower. Water conservation is important because of the increasing usable water shortage, the cost to add infrastructure to deliver increasing amounts of water to accommodate growth and the limitations imposed on disposal to the sewer. Now, due to innovations in chemical treatment, users of cooling towers and evaporative coolers can conserve water. In this presentation the author assumes the audience has some knowledge of traditional water treatment. Except for a few general references to establish common understanding, the author confines his remarks to discussing an advanced technology developed by DIAS, Inc., and the economics of its use.

  9. Simulating a measurement of the 2nd knee in the cosmic ray spectrum with an atmospheric fluorescence telescope tower array.

    PubMed

    Liu, Jiali; Yang, Qunyu; Bai, Yunxiang; Cao, Zhen

    2014-01-01

    A fluorescence telescope tower array has been designed to measure cosmic rays in the energy range of 10(17)-10(18) eV. A full Monte Carlo simulation, including air shower production, light generation and propagation, detector response, electronics, and trigger system, has been developed for that purpose. Using such a simulation tool, the detector configuration, which includes one main tower array and two side-trigger arrays, 24 telescopes in total, has been optimized. The aperture and the event rate have been estimated. Furthermore, the performance of the X max technique in measuring composition has also been studied. PMID:24737964

  10. Simulating a Measurement of the 2nd Knee in the Cosmic Ray Spectrum with an Atmospheric Fluorescence Telescope Tower Array

    PubMed Central

    Liu, Jiali; Yang, Qunyu; Bai, Yunxiang; Cao, Zhen

    2014-01-01

    A fluorescence telescope tower array has been designed to measure cosmic rays in the energy range of 1017–1018 eV. A full Monte Carlo simulation, including air shower production, light generation and propagation, detector response, electronics, and trigger system, has been developed for that purpose. Using such a simulation tool, the detector configuration, which includes one main tower array and two side-trigger arrays, 24 telescopes in total, has been optimized. The aperture and the event rate have been estimated. Furthermore, the performance of the Xmax⁡ technique in measuring composition has also been studied. PMID:24737964

  11. Ignition, Burning, and Extinction of a Strained Fuel Strip

    NASA Technical Reports Server (NTRS)

    Selerland, T.; Karagozian, A. R.

    1996-01-01

    Flame structure and ignition and extinction processes associated with a strained fuel strip are explored numerically using detailed transport and complex kinetics for a propane-air reaction. Ignition modes are identified that are similar to those predicted by one-step activation energy asymptotics, i.e., modes in which diffusion flames can ignite as independent or dependent interfaces, and modes in which single premixed or partially premixed flames ignite. These ignition modes are found to be dependent on critical combinations of strain rate, fuel strip thickness, and initial reactant temperatures. Extinction in this configuration is seen to occur due to fuel consumption by adjacent flames, although viscosity is seen to have the effect of delaying extinction by reducing the effective strain rate and velocity field experienced by the flames.

  12. Aromatic hydrocarbon emissions in the United States deduced from tall tower measurements

    NASA Astrophysics Data System (ADS)

    Hu, L.; Millet, D. B.; Griffis, T. J.; Tessum, C.; Travis, K.

    2013-12-01

    Aromatic compounds including benzene (C6H6), toluene (C7H8), and xylenes (C8H10) are important anthropogenic precursors of secondary organic aerosol and ground-level ozone. In addition, benzene has been classified as a Group 1 carcinogen by the International Agency for Research on Cancer (IARC). However, their emissions remain poorly constrained. Here we present a full year (2011) of continuous aromatic hydrocarbon measurements by PTR-MS at the University of Minnesota tall tower Tracer Gas Observatory (KCMP tall tower, 244 m a.g.l, 44.689°N, 93.073°W). We interpret the tall tower data with a 0.5° ×0.667° GEOS-Chem nested grid simulation to constrain US sources of benzene, toluene, and xylenes. The tall tower observations reveal a clear high bias in the model, with model: measurement slopes of 1.8, 5.3, and 2.9 for benzene, toluene, and xylenes, respectively. The high bias reflects an overestimate of aromatic hydrocarbon emissions in the model, which are based on the RETRO emission Inventory. In this work, we employ a Bayesian inversion to interpret the KCMP tall tower measurements in terms of quantitative constraints on US aromatic sources and the importance of sectors such as on-road transportation, waste treatment and disposal, solvent use, etc. We discuss our findings relative to other emission estimates (e.g., the EPA NEI) and in terms of their implications for air quality modeling.

  13. Buffer strips in composites at elevated temperature

    NASA Technical Reports Server (NTRS)

    Bigelow, C. A.

    1983-01-01

    The composite material 'buffer strip' concept is presently investigated at elevated temperatures for the case of graphite/polyimide buffer strip panels using a (45/0/45/90)2S layup, where the buffer strip material was 0-deg S-glass/polyimide. Each panel was loaded in tension until it failed, and radiographs and crack opening displacements were recorded during the tests to determine fracture onset, fracture arrest, and the extent of damage in the buffer strip after crack arrest. At 177 + or - 3 C, the buffer strips increased the panel strength by at least 40 percent in comparison with panels without buffer strips. Compared to similar panels tested at room temperature, those tested at elevated temperature had lower residual strengths, but higher failure strains.

  14. Strip of heat-recoverable articles

    SciTech Connect

    McLoughlin, R.H.; Kirkham, S.W.

    1985-01-29

    A strip of hollow heat-recoverable articles formed side-by-side by tear welding two lengths of polymeric material together at intervals so that individual articles may be torn off. A preferred method of making the strip involves cross-linking after the tear welding, heating the strip, and inflating the hollow articles to render them heat-recoverable by introducing pressure via an interconnecting passage formed for that purpose during the tear welding.

  15. Method of stripping metals from organic solvents

    DOEpatents

    Todd, Terry A.; Law, Jack D.; Herbst, R. Scott; Romanovskiy, Valeriy N.; Smirnov, Igor V.; Babain, Vasily A.; Esimantovski, Vyatcheslav M.

    2009-02-24

    A new method to strip metals from organic solvents in a manner that allows for the recycle of the stripping agent. The method utilizes carbonate solutions of organic amines with complexants, in low concentrations, to strip metals from organic solvents. The method allows for the distillation and reuse of organic amines. The concentrated metal/complexant fraction from distillation is more amenable to immobilization than solutions resulting from current practice.

  16. Studies of NICADD Extruded Scintillator Strips

    SciTech Connect

    Dychkant, Alexandre; et al.

    2005-03-01

    About four hundred one meter long, 10 cm wide and 5 mm thick extruded scintillating strips were measured at four different points. The results of measurements strip responses to a radioactive source {sup 90}Sr are provided, and details of strip choice, preparation, and method of measurement are included. This work was essential for prototyping a tail catcher and muon tracker for a future international electron positron linear collider detector.

  17. Quantifiable Lateral Flow Assay Test Strips

    NASA Technical Reports Server (NTRS)

    2003-01-01

    As easy to read as a home pregnancy test, three Quantifiable Lateral Flow Assay (QLFA) strips used to test water for E. coli show different results. The brightly glowing control line on the far right of each strip indicates that all three tests ran successfully. But the glowing test line on the middle left and bottom strips reveal their samples were contaminated with E. coli bacteria at two different concentrations. The color intensity correlates with concentration of contamination.

  18. Credit BG. View looking northeast down from the tower onto ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit BG. View looking northeast down from the tower onto the two horizontal test stations at Test Stand "D." Station Dy is at the far left (Dy vacuum cell out of view), with in-line exhaust gas cooling sections and steam-driven "air ejector" (or evacuator) discharging engine exhausts to the east. The Dd cell is visible at the lower left, and the Dd exhaust train has the same functions as at Dy. The spherical tank is an electrically heated "accumulator" which supplies steam to the ejectors at Dv, Dd, and Dy stations. Other large piping delivered cooling water to the horizontal train cooling sections. The horizontal duct at the "Y" branch in the Dd train connects the Dd ejector to the Dv and Cv vacuum duct system (a blank can be bolted into this duct to isolate the Dd system). The shed roof for the Dpond test station appears at bottom center of this image. The open steel frame to the lower left of the image supports a hoist and crane for installing or removing test engines from the Dd test cell - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  19. Innovative Air Conditioning and Climate Control

    NASA Technical Reports Server (NTRS)

    Graf, John

    2015-01-01

    NASA needed to develop a desiccant wheel based humidity removal system to enable the long term testing of the Orion CO2 scrubber on the International Space Station. In the course of developing that system, we learned three things that are relevant to energy efficient air conditioning of office towers. NASA developed a conceptual design for a humidity removal system for an office tower environment. We are looking for interested partners to prototype and field test this concept.

  20. Reuse of pretreated coal gasification condensate in a pilot scale cooling tower

    SciTech Connect

    Johnson, M.D.; Schweitzer, G.W.

    1987-01-01

    The recycle of wastewaters to cooling water systems is practiced in many industrial sectors. The Great Plains Gasification Plant (GPGP) located near Beulah, North Dakota, for example, was designed to reuse treated gas liquor as the primary source of makeup water. In other industrial plants, the concentration of contaminants in the makeup water is very low or the wastewater comprises only a small fraction of the total makeup to the cooling system. The Great Plains system is unique in that the stripped gas liquor (SGL) used as makeup contains relatively high concentrations of dissolved organics, ammonia and acid gases. In addition, the SGL constitutes over 90% of the total makeup to the system. The use of pretreated gas liquor in open, circulating cooling systems is an untried approach to wastewater recycle. The plant not only eliminates a large discharge problem but gains a valuable makeup source for the cooling towers. Because of the large heat duties for the cooling system in these types of plants and their location of regions of water shortages, this approach can be very beneficial. However, there are several environmental and operational concerns that have yet to be resolved. These include atmospheric emissions, fouling of heat transfer surfaces and cooling tower equipment, and excessive corrosion of system components.

  1. Conceptual Design Gamma-Ray Large Area Space Telescope (GLAST) Tower Structure

    SciTech Connect

    Jennings, Chad

    2002-07-18

    The main objective of this work was to develop a conceptual design and engineering prototype for the Gamma-ray Large Area Space Telescope (GLAST) tower structure. This thesis describes the conceptual design of a GLAST tower and the fabrication and testing of a prototype tower tray. The requirements were that the structure had to support GLAST's delicate silicon strip detector array through ground handling, launch and in orbit operations as well as provide for thermal and electrical pathways. From the desired function and the given launch vehicle for the spacecraft that carries the GLAST detector, an efficient structure was designed which met the requirements. This thesis developed in three stages: design, fabrication, and testing. During the first stage, a general set of specifications was used to develop the initial design, which was then analyzed and shown to meet or exceed the requirements. The second stage called for the fabrication of prototypes to prove manufacturability and gauge cost and time estimates for the total project. The last step called for testing the prototypes to show that they performed as the analysis had shown and prove that the design met the requirements. As a spacecraft engineering exercise, this project required formulating a solution based on engineering judgment, analyzing the solution using advanced engineering techniques, then proving the validity of the design and analysis by the manufacturing and testing of prototypes. The design described here met all the requirements set out by the needs of the experiment and operating concerns. This strawman design is not intended to be the complete or final design for the GLAST instrument structure, but instead examines some of the main challenges involved and demonstrates that there are solutions to them. The purpose of these tests was to prove that there are solutions to the basic mechanical, electrical and thermal problems presented with the GLAST project.

  2. Bonded orthotropic strips with cracks

    NASA Technical Reports Server (NTRS)

    Delale, F.; Erdogan, F.

    1979-01-01

    The elastostatic problem for a nonhomogeneous plane which consists of two sets of periodically arranged dissimilar orthotropic strips is considered. It is assumed that the plane contains a series of collinear cracks perpendicular to the interfaces and is loaded in tension away from and perpendicular to the cracks. The problem of cracks fully imbedded into the homogeneous strips is considered. The singular behavior of the stresses for two special crack geometries is studied. The first is the case of a broken laminate in which the crack tips touch the interfaces. The second is the case of cracks crossing the interfaces. An interesting result found from the analysis of the latter is that for certain orthotropic material combinations the stress state at the point of intersection of a crack and an interface may be bounded whereas in isotropic materials at this point stresses are always singular. A number of numerical examples are worked out to separate the primary material parameters influencing the stress intensity factors and the powers of stress singularity, and to determine the trends regarding the influence of the secondary parameters. Some numerical results are given for the stress intensity factors in certain basic crack geometries and for typical material combinations.

  3. 37. VIEW LOOKING SOUTH AT THE STATIC TEST TOWER. THIS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. VIEW LOOKING SOUTH AT THE STATIC TEST TOWER. THIS VIEW SHOWS TWO MAJOR CHANGES TO THE STATIC TEST TOWER: THE ADDITION OF THE NASA LOGO TO THE FACADE AND THE ADDITION OF THE UPPER STAGES TO THE JUPITER MISSILE IN THE WEST POSITION ON THE TOWER TO REPRESENT THE JUNO II CONFIGURATION. 1961, PHOTOGRAPHER UNKNOWN, FRED ORDWAY COLLECTION, U. S. SPACE AND ROCKET CENTER, HUNTSVILLE, AL. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  4. Technical Evaluation of Side Stream Filtration for Cooling Towers

    SciTech Connect

    2012-10-01

    Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. Cooling towers represent the point in a cooling system where heat is dissipated to the atmosphere through evaporation. Cooling towers are commonly used in industrial applications and in large commercial buildings to release waste heat extracted from a process or building system through evaporation of water.

  5. 93. TOWER STAIRHALL, SOUTH WALL, WEST TABERNACLE FRAME. DETAIL OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    93. TOWER STAIRHALL, SOUTH WALL, WEST TABERNACLE FRAME. DETAIL OF DOG EAR AND TRUSS (BRACKET) - Independence Hall Complex, Independence Hall, 500 Chestnut Street, Philadelphia, Philadelphia County, PA

  6. A numerical simulation of heat transfer in evaporative cooling towers

    NASA Astrophysics Data System (ADS)

    Benton, D. J.

    1983-09-01

    A phenomenological analysis was developed for the processes which occur within an evaporative cooling tower. The analysis includes the basic principles of mass, momentum, and energy conservation and empirical elationships for component characteristics such as transfer and pressure drop coefficients. A computer model which simulates the processes occurring in evaporative cooling towers was developed. The results of this computer model are compared to field data to verify the analysis and the computer modeling. The computer model may be used to analyze the performance of existing towers or to predict the performance of alternative tower designs.

  7. Optimal Inflatable Space Towers with 3 - 100 km Height

    NASA Technical Reports Server (NTRS)

    Bolonkin, Alexander

    2003-01-01

    Theory and computations are provided for building inflatable space towers up to one hundred kilometers in height. These towers can be used for tourism, scientific observation of space, observation of the Earth's surface, weather and upper atmosphere, and for radio, television, and communication transmissions. These towers can also be used to launch space ships and Earth satellites. These projects are not expensive and do not require rockets. They require thin strong films composed from artificial fibers and fabricated by current industry. The towers can be built using present technology. The towers can be used (for tourism, communication, etc.) during the construction process and provide self-financing for further construction. The tower design does not require work at high altitudes; all construction can be done at the Earth's surface. The transport system for a tower consists of a small engine (used only for friction compensation) located at the Earth's surface. The tower is separated into sections and has special protection mechanisms in case of damage. Problems involving security, control, repair, and stability of the proposed towers are addressed in other publications. The author is prepared to discuss these and other problems with serious organizations desiring to research and develop these projects.

  8. Convective Cloud Towers and Precipitation Initiation, Frequency and Intensity

    NASA Astrophysics Data System (ADS)

    Vant-hull, B.; Mahani, S. E.; Autones, F.; Rabin, R.; Mecikalski, J. R.; Khanbilvardi, R.

    2012-12-01

    : Geosynchronous satellite retrieval of precipitation is desirable because it would provide continuous observation throughout most of the globe in regions where radar data is not available. In the current work the distribution of precipitation rates is examined as a function of cloud tower area and cloud top temperature. A thunderstorm tracking algorithm developed at Meteo-France is used to track cumulus towers that are matched up with radar data at 5 minute 1 km resolution. It is found that roughly half of the precipitation occurs in the cloud mass that surrounds the towers, and when a tower is first detected the precipitation is already in progress 50% of the time. The average density of precipitation per area is greater as the towers become smaller and colder, yet the averaged shape of the precipitation intensity distribution is remarkably constant in all convective situations with cloud tops warmer than 220 K. This suggests that on average all convective precipitation events look the same, unaffected by the higher frequency of occurrence per area inside the convective towers. Only once the cloud tops are colder than 220 K does the precipitation intensity distribution become weighted towards higher instantaneous intensities. Radar precipitation shown in shades of green to blue, lightning in orange; black diamonds are coldest points in each tower. Ratio of number of pixels of given precipitation inside versus outside the convective towers, for various average cloud top temperatures. A flat plot indicates the distribution of rainfall inside and outside the towers has the same shape.

  9. 9. DETAIL, NORTH FRONT, CENTRAL (TALLEST) TOWER, FROM THE NORTHWEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. DETAIL, NORTH FRONT, CENTRAL (TALLEST) TOWER, FROM THE NORTHWEST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  10. 44. ARTS AND INDUSTRIES BUILDING FROM SOUTH TOWER ROOF, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. ARTS AND INDUSTRIES BUILDING FROM SOUTH TOWER ROOF, LOOKING SOUTHEAST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  11. 39. CLOSER VIEW OF CAMPANILE FROM SOUTH TOWER ROOF, LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. CLOSER VIEW OF CAMPANILE FROM SOUTH TOWER ROOF, LOOKING NORTHEAST - Smithsonian Institution Building, 1000 Jefferson Drive, between Ninth & Twelfth Streets, Southwest, Washington, District of Columbia, DC

  12. Interior detail of tower space; camera facing southwest. Mare ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior detail of tower space; camera facing southwest. - Mare Island Naval Shipyard, Defense Electronics Equipment Operating Center, I Street, terminus west of Cedar Avenue, Vallejo, Solano County, CA

  13. 8. STATIC TEST TOWER NORTHWEST ELEVATION FROM THE POWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. STATIC TEST TOWER - NORTHWEST ELEVATION FROM THE POWER PLANT TEST STAND. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  14. 2. HI PAR (ACQUISITION RADAR) TOWER AND ENLISTED MEN (EM) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. HI PAR (ACQUISITION RADAR) TOWER AND ENLISTED MEN (EM) BARRACKS WITH RADAR ATTACHED. - Nike Hercules Missile Battery Summit Site, Battery Control Administration & Barracks Building, Anchorage, Anchorage, AK

  15. The Damaging Effects of Earthquake Excitation on Concrete Cooling Towers

    SciTech Connect

    Abedi-Nik, Farhad; Sabouri-Ghomi, Saeid

    2008-07-08

    Reinforced concrete cooling towers of hyperbolic shell configuration find widespread application in utilities engaged in the production of electric power. In design of critical civil infrastructure of this type, it is imperative to consider all the possible loading conditions that the cooling tower may experience, an important loading condition in many countries is that of the earthquake excitation, whose influence on the integrity and stability of cooling towers is profound. Previous researches have shown that the columns supporting a cooling tower are sensitive to earthquake forces, as they are heavily loaded elements that do not possess high ductility, and understanding the behavior of columns under earthquake excitation is vital in structural design because they provide the load path for the self weight of the tower shell. This paper presents the results of a finite element investigation of a representative 'dry' cooling tower, using realistic horizontal and vertical acceleration data obtained from the recent and widely-reported Tabas, Naghan and Bam earthquakes in Iran. The results of both linear and nonlinear analyses are reported in the paper, the locations of plastic hinges within the supporting columns are identified and the ramifications of the plastic hinges on the stability of the cooling tower are assessed. It is concluded that for the (typical) cooling tower configuration analyzed, the columns that are instrumental in providing a load path are influenced greatly by earthquake loading, and for the earthquake data used in this study the representative cooling tower would be rendered unstable and would collapse under the earthquake forces considered.

  16. Dynamic testing of NOVA laser switchyard tower

    SciTech Connect

    Weaver, H.J.; Pastrnak, J.W.; Fields, D.E.

    1984-06-01

    NOVA is the latest in a series of powerful laser systems designed to study the feasibility of initiating a controlled fusion reaction by concentrating several laser beams on a small fuel target. The laser components, turning mirrors and target chamber are all mounted on large steel frame structures. These structures were first analyzed via finite element models to access their seismic integrity as well as their overall vibrational stability. When construction was completed, a modal analysis was performed on the structures to verify and improve the finite element models. This report discusses the linking of the analytical and experimental studies for the NOVA switchyard tower structure.

  17. There's Money in Those Towers! Communication Towers Can Be Money Makers.

    ERIC Educational Resources Information Center

    Perry, Richard E.

    1995-01-01

    To interlink major systems, some communication companies are proposing construction of communication towers on school grounds. Schools and municipal governments possess strategically located, unzoned properties. Districts planning to tap this financial oil well should draw up a lease agreement specifying property use, term, rent, access rights,…

  18. Air Controlman 1 & C: Rate Training Manual.

    ERIC Educational Resources Information Center

    Naval Training Command, Pensacola, FL.

    The manual is designed for use in preparing for advancement within the Navy Air Controlman rating, which designates a professional air traffic controller, unlike the more specialized center or tower controllers. However, minimum qualifications for the rating include completion of the Federal Aviation Administration (FAA) written examination for…

  19. Strategy Strips for Self-Reliant Readers.

    ERIC Educational Resources Information Center

    Sowell, Dorothy J.

    2003-01-01

    Explains how reading strategy strips were developed to focus students' attention on specific reading steps. Notes that students became more personally knowledgeable and independent by using reading strategy strips. Proposes that their small-group participation helped them progress as collaborative thinkers. (PM)

  20. 33 CFR 157.128 - Stripping system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Crude Oil Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.128 Stripping...) must have a stripping system that is designed to remove crude oil from— (1) Each cargo tank at 1.25... under § 157.140(a)(2). (b) Each cargo tank must be designed to allow the level of crude oil in the...

  1. 33 CFR 157.128 - Stripping system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Crude Oil Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.128 Stripping...) must have a stripping system that is designed to remove crude oil from— (1) Each cargo tank at 1.25... under § 157.140(a)(2). (b) Each cargo tank must be designed to allow the level of crude oil in the...

  2. In-situ conditioning of a strip casting roll

    DOEpatents

    Williams, Robert S.; Campbell, Steven L.

    1997-01-01

    A strip caster (10) for producing a continuous strip (24) has a tundish (12) for containing a melt (14) and a pair of horizontally disposed water cooled casting rolls (22). The casting rolls are juxtaposed relative to one another for forming a pouring basin (18) for receiving the melt through a teeming tube (16) thereby establishing a meniscus (20) between the rolls for forming a strip (24). The melt is protected from the outside air by a non-oxidizing gas passed through a supply line (28) to a sealing chamber (26). Devices (29) for conditioning the outer peripheral chill surfaces of the casting rolls includes grit blasting nozzles (30A, 30B, 30C, 30D), a collection trough (32) for gathering the grit, a line (34) for recycling the grit to a bag house (36), a feeder (38) and a pressurized distributor (40) for delivering the grit to the nozzles. The conditioning nozzles remove dirt, metal oxides and surface imperfections providing a clean surface readily wetted by the melt.

  3. In-situ conditioning of a strip casting roll

    DOEpatents

    Williams, R.S.; Campbell, S.L.

    1997-07-29

    A strip caster (10) for producing a continuous strip (24) has a tundish (12) for containing a melt (14) and a pair of horizontally disposed water cooled casting rolls (22). The casting rolls are juxtaposed relative to one another for forming a pouring basin (18) for receiving the melt through a teeming tube (16) thereby establishing a meniscus (20) between the rolls for forming a strip (24). The melt is protected from the outside air by a non-oxidizing gas passed through a supply line (28) to a sealing chamber (26). Devices (29) for conditioning the outer peripheral chill surfaces of the casting rolls includes grit blasting nozzles (30A, 30B, 30C, 30D), a collection trough (32) for gathering the grit, a line (34) for recycling the grit to a bag house (36), a feeder (38) and a pressurized distributor (40) for delivering the grit to the nozzles. The conditioning nozzles remove dirt, metal oxides and surface imperfections providing a clean surface readily wetted by the melt.

  4. Smooth Muscle Strips for Intestinal Tissue Engineering

    PubMed Central

    Walthers, Christopher M.; Lee, Min; Wu, Benjamin M.; Dunn, James C. Y.

    2014-01-01

    Functionally contracting smooth muscle is an essential part of the engineered intestine that has not been replicated in vitro. The purpose of this study is to produce contracting smooth muscle in culture by maintaining the native smooth muscle organization. We employed intact smooth muscle strips and compared them to dissociated smooth muscle cells in culture for 14 days. Cells isolated by enzymatic digestion quickly lost maturity markers for smooth muscle cells and contained few enteric neural and glial cells. Cultured smooth muscle strips exhibited periodic contraction and maintained neural and glial markers. Smooth muscle strips cultured for 14 days also exhibited regular fluctuation of intracellular calcium, whereas cultured smooth muscle cells did not. After implantation in omentum for 14 days on polycaprolactone scaffolds, smooth muscle strip constructs expressed high levels of smooth muscle maturity markers as well as enteric neural and glial cells. Intact smooth muscle strips may be a useful component for engineered intestinal smooth muscle. PMID:25486279

  5. Submarine tower escape decompression sickness risk estimation.

    PubMed

    Loveman, G A M; Seddon, E M; Thacker, J C; Stansfield, M R; Jurd, K M

    2014-01-01

    Actions to enhance survival in a distressed submarine (DISSUB) scenario may be guided in part by knowledge of the likely risk of decompression sickness (DCS) should the crew attempt tower escape. A mathematical model for DCS risk estimation has been calibrated against DCS outcome data from 3,738 exposures of either men or goats to raised pressure. Body mass was used to scale DCS risk. The calibration data included more than 1,000 actual or simulated submarine escape exposures and no exposures with substantial staged decompression. Cases of pulmonary barotrauma were removed from the calibration data. The calibrated model was used to estimate the likelihood of DCS occurrence following submarine escape from the United Kingdom Royal Navy tower escape system. Where internal DISSUB pressure remains at - 0.1 MPa, escape from DISSUB depths < 200 meters is estimated to have DCS risk < 6%. Saturation at raised DISSUB pressure markedly increases risk, with > 60% DCS risk predicted for a 200-meter escape from saturation at 0.21 MPa. Using the calibrated model to predict DCS for direct ascent from saturation gives similar risk estimates to other published models. PMID:25109085

  6. Meteorological Towers Display for Windows NT

    1999-05-20

    The Towers Display Program provides a convenient means of graphically depicting current wind speed and direction from a network of meteorological monitoring stations. The program was designed primarily for emergency response applications and, therefore, plots observed wind directions as a transport direction, i.e., the direction toward which the wind would transport a release of an atmospheric contaminant. Tabular summaries of wind speed and direction as well as temperature, relative humidity, and atmospheric turbulence measured atmore » each monitoring station can be displayed. The current implementation of the product at SRS displays data from eight Weather INformation and Display (WIND) System meteorological towers at SRS, meteorological stations established jointly by SRS/WSRC and the Augusta/Richmond County Emergency Management Agency in Augusta, GA, and National Weather Service stations in Augusta, GA. Wind speed and direction are plotted in a Beaufort scale format at the location of the station on a geographic map of the area. A GUI provides for easy specification of a desired date and time for the data to be displayed.« less

  7. 6. VIEW OF ANTENNA TOWER S111 FACING NORTHWEST. COMMUNICATIONS CONTROL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW OF ANTENNA TOWER S-111 FACING NORTHWEST. COMMUNICATIONS CONTROL LINK BUILDING (BLDG NO. 205) LOCATED JUST INFONT OF THE TOWER. - U.S. Naval Base, Pearl Harbor, Lualualei Radio Transmitter, Edison & Tower Drives, Pearl City, Honolulu County, HI

  8. 1. Oil house, keeper's house, Southern Light Tower and Northern ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Oil house, keeper's house, Southern Light Tower and Northern Light Tower, view northwest, south and east sides - Kennebec River Light Station, South side of Doubling Point Road, off State Highway 127, 1.8 miles south of U.S. Route 1, Arrowsic, Sagadahoc County, ME

  9. 2. Barn, light tower and keeper's house, view southeast, west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Barn, light tower and keeper's house, view southeast, west and north sides of barn, northwest side of light tower, and west northwest and north northeast sides of keeper's house - Curtis Island Light Station, Curtis Island, at entrance to Camden Harbor, Camden, Knox County, ME

  10. 16. Detail, northeast facade, operator's bow window and tower; note ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. Detail, northeast facade, operator's bow window and tower; note condition of slates on tower skirt roof, missing section of gutter at left side of skirt roof, missing window panes; note also knee braces carried on masonry ancons; view to southwest, 90mm lens. - Southern Pacific Depot, 559 El Camino Real, San Carlos, San Mateo County, CA

  11. 2. Light tower and oil house, view west, southeast and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Light tower and oil house, view west, southeast and northeast sides of tower and south side of oil house - Goat Island Light Station, Goat Island, next to entrance to Cape Porpoise Harbor, just south of Trott Island, Cape Porpoise, York County, ME

  12. 2. Keeper's house, light tower and oil house, view north, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Keeper's house, light tower and oil house, view north, south and east sides of keeper's house, south side of tower and oil house - Owl's Head Light Station, Off State Highway 73 just east of Rockland on Owl's Head Bay, Owls Head, Knox County, ME

  13. OVERVIEW OF AERIAL TRAM SUPPORT TOWERS NINE, TEN, AND DEEP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    OVERVIEW OF AERIAL TRAM SUPPORT TOWERS NINE, TEN, AND DEEP RAVINE,LOOKING SOUTH FROM BREAK OVER TOWER LOCATION. A SINGLE ORE BUCKET HANGS FROM THE CABLE AT CENTER. DEATH VALLEY'S FLOOR IS IN THE DISTANCE (TOP). - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA

  14. 8. INTERIOR VIEW OF ASSEMBLY ROOM (REAR FACADE), UNTANKING TOWER, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. INTERIOR VIEW OF ASSEMBLY ROOM (REAR FACADE), UNTANKING TOWER, SHOWING PREVIOUS MODIFICATIONS (INSTALLATION OF METAL ROLL-UP DOOR, LEFT FOREGROUND). 125-TON LIFTING CRANE (TOP FOREGROUND), AND ORIGINAL FLOOR-TO-CEILING MULTI-PANE, METAL-CASED WINDOWS - Bonneville Power Administration Chehalis Substation, Untanking Tower, State Route 603, West of Interstate 5, Napavine, Lewis County, WA

  15. 34. VIEW LOOKING NORTHEAST AT THE STATIC TEST TOWER. MODIFICATIONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. VIEW LOOKING NORTHEAST AT THE STATIC TEST TOWER. MODIFICATIONS TO THE EAST SIDE OF THE TOWER ARE NEARING COMPLETION. NOTE THAT THE HORIZON HAS BEEN MODIFIED TO DISGUISE THE LOCATION. 1959, PHOTOGRAPHER UNKNOWN, MSFC PHOTO LAB. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  16. 15. Como gatehouse (outlet tower) and access bridge, looking west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Como gatehouse (outlet tower) and access bridge, looking west from dam crest (Trash rack visible in reservoir pool behind and right of tower) - Bitter Root Irrigation Project, Como Dam, West of U.S. Highway 93, Darby, Ravalli County, MT

  17. Sequoias, Mavericks, Open Doors...Composing Joan Tower

    ERIC Educational Resources Information Center

    Allsup, Randall Everett

    2011-01-01

    This essay interview with Joan Tower is a meditation on the importance of composing, understood as a process larger than the making of new sound combinations or musical scores, suggesting that the compositional act is self-educative and self-forming. Tower's musical life, one of teaching and learning, one of composing and self-composing, is an…

  18. 1. Keeper's house, small boathouse, and light tower, view east, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Keeper's house, small boathouse, and light tower, view east, west and south sides of keeper's house, west side of boathouse and tower - Great Duck Island Light Station, At southern tip of Great Duck Island southeast of Bass Harbor & northeast of Frenchboro, Frenchboro, Hancock County, ME

  19. 25. Wood quench tower, chemical tank on right, hot gas ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. Wood quench tower, chemical tank on right, hot gas pipes between coke ovens and compressor building XX), coal conveyor to pulverizer building on right, water tank to left of quench tower. Looking north/northwest - Rouge Steel Company, 3001 Miller Road, Dearborn, MI

  20. 18. DETAIL VIEW OF A TYPICAL TOWER FROM OPERATOR'S CABIN, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. DETAIL VIEW OF A TYPICAL TOWER FROM OPERATOR'S CABIN, LOOKING WEST-NORTHWEST (Vignetting caused by extreme camera shift required to hold entire tower in view) - Sacramento River Bridge, Spanning Sacramento River at California State Highway 275, Sacramento, Sacramento County, CA

  1. Cell block three and northeast guard tower (center), looking from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Cell block three and northeast guard tower (center), looking from the central guard tower, facing northeast (note view also includes the baseball field (left), and cell blocks fourteen and eleven (right)) - Eastern State Penitentiary, 2125 Fairmount Avenue, Philadelphia, Philadelphia County, PA

  2. 1. Light tower and fog signal house, view south southeast, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Light tower and fog signal house, view south southeast, east and north sides of tower, northeast and northwest sides of signal house - Libby Island Light Station, At southern tip of Libby Island at entrance to Machias Bay, Machiasport, Washington County, ME

  3. 7. Keeper's house, fog signal house and light tower, view ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Keeper's house, fog signal house and light tower, view north northeast, west and south sides of keeper's house and tower, southwest and southeast sides of fog signal house - West Quoddy Head Light Station, At eastern tip of West Quaddy Head, Lubec, Washington County, ME

  4. 2. Fog signal house and light tower, view west southwest, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Fog signal house and light tower, view west southwest, southeast and northeast sides of signal house, east and north sides of tower - Libby Island Light Station, At southern tip of Libby Island at entrance to Machias Bay, Machiasport, Washington County, ME

  5. 13. View of Truss tower and pivot pier locking east. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. View of Truss tower and pivot pier locking east. When the draw is open, the two arms of the truss act as cantilevers supported by the truss tower. A counterweight in the shorter of the bridge keeps the span in proper balance. - Center Street Swing Bridge, Southwest of Public Square, Cleveland, Cuyahoga County, OH

  6. 47 CFR 5.109 - Antenna and tower requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Antenna and tower requirements. 5.109 Section 5... BROADCAST) Technical Standards and Operating Requirements § 5.109 Antenna and tower requirements. (a) Applicants with fixed stations that use antennas that exceed 6 meters in height above the ground level...

  7. 47 CFR 5.109 - Antenna and tower requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Antenna and tower requirements. 5.109 Section 5... BROADCAST) Technical Standards and Operating Requirements § 5.109 Antenna and tower requirements. (a) Applicants with fixed stations that use antennas that exceed 6 meters in height above the ground level...

  8. 47 CFR 5.109 - Antenna and tower requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Antenna and tower requirements. 5.109 Section 5... BROADCAST) Technical Standards and Operating Requirements § 5.109 Antenna and tower requirements. (a) Applicants with fixed stations that use antennas that exceed 6 meters in height above the ground level...

  9. 4. Keeper's house and light tower, view northeast, southwest side ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Keeper's house and light tower, view northeast, southwest side of house, northwest front and southwest side of tower - Burnt Coat Harbor Light Station, At Hackamock Head on Swan's Island opposite Harbor Island at entrance to Burnt Coat Harbor, Swans Island, Hancock County, ME

  10. 6. Light tower and corner of keeper's house, view northeast, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Light tower and corner of keeper's house, view northeast, northwest front and southwest side of tower, southwest side of house - Burnt Coat Harbor Light Station, At Hackamock Head on Swan's Island opposite Harbor Island at entrance to Burnt Coat Harbor, Swans Island, Hancock County, ME

  11. 3. Bell house, light tower and keeper's house, view west, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Bell house, light tower and keeper's house, view west, southeast side and northeast front of bell house, southeast sides of tower and keeper's house - Burnt Coat Harbor Light Station, At Hackamock Head on Swan's Island opposite Harbor Island at entrance to Burnt Coat Harbor, Swans Island, Hancock County, ME

  12. 5. Light tower and corner of keeper's house, view south, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Light tower and corner of keeper's house, view south, northeast side and northwest front of tower, northeast side of house - Burnt Coat Harbor Light Station, At Hackamock Head on Swan's Island opposite Harbor Island at entrance to Burnt Coat Harbor, Swans Island, Hancock County, ME

  13. Main photoautotrophic components of biofilms in natural draft cooling towers.

    PubMed

    Hauer, Tomáš; Čapek, Petr; Böhmová, Petra

    2016-05-01

    While photoautotrophic organisms are an important component of biofilms that live in certain regions of natural draft cooling towers, little is known about these communities. We therefore examined 18 towers at nine sites to identify the general patterns of community assembly in three distinct tower parts, and we examined how community structures differ depending on geography. We also compared the newly acquired data with previously published data. The bottom sections of draft cooling towers are mainly settled by large filamentous algae, primarily Cladophora glomerata. The central portions of towers host a small amount of planktic algae biomass originating in the cooling water. The upper fourths of towers are colonized by biofilms primarily dominated by cyanobacteria, e.g., members of the genera Gloeocapsa and Scytonema. A total of 41 taxa of phototrophic microorganisms were identified. Species composition of the upper fourth of all towers was significantly affected by cardinal position. There was different species composition at positions facing north compared to positions facing south. West- and east-facing positions were transitory and highly similar to each other in terms of species composition. Biofilms contribute to the degradation of paint coatings inside towers. PMID:26508444

  14. 36. EASTERN VIEW OF BOTTOM CONE OF GAS COOLING TOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. EASTERN VIEW OF BOTTOM CONE OF GAS COOLING TOWER No. 1 AND TWO GAS COOLING TOWER SERVICE WATER PUMPS IN THE GAS WASHER PUMP HOUSE. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  15. 1. Shed, railroad, keeper's house, light tower and boathouse, view ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Shed, railroad, keeper's house, light tower and boathouse, view southwest, northeast side of shed, keeper's house and tower, east and north sides of boathouse - Seguin Island Light Station, Summit of Seguin Island, south of mouth of Kennebec River, Popham Beach, Sagadahoc County, ME

  16. 2. Shed, railroad, light tower and boathouse, view south southwest, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. Shed, railroad, light tower and boathouse, view south southwest, northeast and northwest sides of shed, northeast side of tower, east and north sides of boathouse - Seguin Island Light Station, Summit of Seguin Island, south of mouth of Kennebec River, Popham Beach, Sagadahoc County, ME

  17. 3. Railroad viaduct, keeper's house, light tower and shed, view ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Railroad viaduct, keeper's house, light tower and shed, view west, southeast side of viaduct, southeast and northeast sides of keeper's house, tower and shed - Seguin Island Light Station, Summit of Seguin Island, south of mouth of Kennebec River, Popham Beach, Sagadahoc County, ME

  18. 32. VIEW LOOKING EAST AT THE STATIC TEST TOWER WHILE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. VIEW LOOKING EAST AT THE STATIC TEST TOWER WHILE A JUPITER MISSILE IS BEING POSITIONED ONTO THE TEST TOWER. DATE AND PHOTOGRAPHER UNKNOWN, MSFC PHOTO LAB. - Marshall Space Flight Center, Saturn Propulsion & Structural Test Facility, East Test Area, Huntsville, Madison County, AL

  19. Detail of conning tower atop the submarine. Note the wire ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of conning tower atop the submarine. Note the wire rope wrapped around the base of the tower, which may have been used in an attempt to pull the submarine offshore. - Sub Marine Explorer, Located along the beach of Isla San Telmo, Pearl Islands, Isla San Telmo, Former Panama Canal Zone, CZ

  20. VIEW LOOKING NW FROM CATWALK OF SE TOWER, SHOWING INTERIOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW LOOKING NW FROM CATWALK OF SE TOWER, SHOWING INTERIOR ELEVATION OF TOWER OPPOSITE. NOTE THAT CONCRETE PIERS DO NOT MATCH FOOTINGS PROJECTING SLIGHTLY ABOVE WATER. - Lake Shore & Michigan Southern Railway, Bridge No. 6, Spanning Calumet River, east of Chicago Skyway (I-90), Chicago, Cook County, IL

  1. In Hot Water: A Cooling Tower Case Study

    ERIC Educational Resources Information Center

    Cochran, Justin; Raju, P. K.; Sankar, Chetan

    2005-01-01

    Problem Statement: Vogtle Electric Generating Plant operated by Southern Nuclear Operating Company, a subsidiary of Southern Company, has found itself at a decision point. Vogtle depends on their natural draft cooling towers to remove heat from the power cycle. Depending on the efficiency of the towers, the cycle can realize more or less power…

  2. In Hot Water: A Cooling Tower Case Study. Instructor's Manual

    ERIC Educational Resources Information Center

    Cochran, Justin; Raju, P. K.; Sankar, Chetan

    2005-01-01

    Vogtle Electric Generating Plant operated by Southern Nuclear Operating Company, a subsidiary of Southern Company, has found itself at a decision point. Vogtle depends on their natural draft cooling towers to remove heat from the power cycle. Depending on the efficiency of the towers, the cycle can realize more or less power output. The efficiency…

  3. 18. Upstream face of arches, concrete placing tower is at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Upstream face of arches, concrete placing tower is at far right. Tower at center was used to convey material. Photographer unknown, January 29, 1927. Source: MWD. - Waddell Dam, On Agua Fria River, 35 miles northwest of Phoenix, Phoenix, Maricopa County, AZ

  4. PBF Cooling Tower. View of stairway to fan deck. Vents ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Cooling Tower. View of stairway to fan deck. Vents are made of redwood. Camera facing southwest toward north side of Cooling Tower. Siding is corrugated asbestos concrete. Photographer: Kirsh. Date: June 6, 1969. INEEL negative no. 69-3463 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  5. 1. VIEW NORTHWEST, NORTHEAST SIDE AND SOUTHEAST FRONT OF TOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW NORTHWEST, NORTHEAST SIDE AND SOUTHEAST FRONT OF TOWER AND ORIGINAL LIGHTHOUSE - Mispillion Lighthouse, Beacon Tower, South bank of Mispillion River at it confluence with Delaware River at northeast end of County Road 203, 7 miles east of Milford, Milford, Sussex County, DE

  6. Enumeration of Legionella pneumophila in cooling tower water systems.

    PubMed

    Türetgen, Irfan; Sungur, Esra Ilhan; Cotuk, Aysin

    2005-01-01

    Legionella pneumophila, the causative agent of Legionnaires' disease, is known to colonise and frequently grow in cooling tower waters. Disease is acquired by inhaling aerosol contaminated by legionellae. Determination of the count of Legionella pneumophila in cooling tower waters may, therefore, be useful for risk assessment. In our survey, 103 water samples from 50 cooling towers were examined over a five-year period to indicate the seasonal distribution and the ecology of L. pneumophila, as regards temperature and pH. L. pneumophila serogroup 1 was found in 44% of the isolated strains, which is primarily responsible for the majority of Legionnaires' disease. The large majority of examined towers had levels of L. pneumophila in the high-risk category. These cooling towers have been linked to many outbreaks of Legionnaires' disease. PMID:15727299

  7. Remote monitoring and nondestructive evaluation of wind turbine towers

    NASA Astrophysics Data System (ADS)

    Chiang, Chih-Hung; Yu, Chih-Peng; Hsu, Keng-Tsang; Cheng, Chia-Chi; Ke, Ying-Tzu; Shih, Yi-Ru

    2014-03-01

    Wind turbine towers are in need of condition monitoring so as to lower the cost of unexpected maintenance. Wind loading from turbulence and gusts can cause damage in horizontal axis wind turbines even the supporting towers. Monitoring of wind turbines in service using embedded data sensor arrays usually is not targeted at the turbine-tower interaction from the perspective of structural dynamics. In this study the remote monitoring of the tower supporting a horizontal-axis wind turbine was attempted using a microwave interferometer. The dominant frequency of one tower was found to be decreased by more than 20% in 16 months. Numerical modeling using spectral finite elements is in progress and should provide further information regarding frequency shift due to stiffness variation and added mass. Expected outcome will contribute to remote monitoring procedures and nondestructive evaluation techniques for local wind turbine structures during operation.

  8. Evaluation of IR technology applied to cooling tower performance

    NASA Astrophysics Data System (ADS)

    MacNamara, Neal A.; Zayicek, Paul A.

    1999-03-01

    Infrared thermography (IR) is widely used by electric utilities as an integral part of their predictive maintenance program. IR is utilized for inspection of a variety of plant mechanical and electrical components. Additionally, IR can be used to provide thermal performance information for other key plant systems, including assessment of cooling towers. Cooling tower performance directly affects availability and heat rate in fossil and nuclear power plants. Optimal tower performance contributes to efficient turbine operation and maximum power output. It is estimated that up to half of the cooling towers installed have failed to meet their design performance specifications. As a result, any additional degradation of tower performance resulting from fouling, valve degradation, unbalanced flow, or a poor maintenance practice has a direct effect on generation output. We have collected infrared thermography images of mechanical draft cooling towers, as part of Evaluation of IR Technology Applied to Cooling Tower Performance. IR images have been analyzed to provide information regarding general performance conditions and identification of operational deficiencies related to thermal performance. Similarly, IR can be implemented for monitoring of tower flow balance activities and for post-maintenance surveillance. To date, IR images have been used to identify areas of general flow imbalance, flooding or limited flow in individual cells, missing or broken tower fill material, fan performance and other problems related to maintenance or operational issues. Additionally, an attempt is being made to use quantitative thermal data, provided by the IR image analysis software, in conjunction with condenser input/output site ambient information, to evaluate and compare individual tower cell performance.

  9. A Strip Cell in Pyroelectric Devices.

    PubMed

    Siao, An-Shen; Chao, Ching-Kong; Hsiao, Chun-Ching

    2016-01-01

    The pyroelectric effect affords the opportunity to convert temporal temperature fluctuations into usable electrical energy in order to develop abundantly available waste heat. A strip pyroelectric cell, used to enhance temperature variation rates by lateral temperature gradients and to reduce cell capacitance to further promote the induced voltage, is described as a means of improving pyroelectric energy transformation. A precision dicing saw was successfully applied in fabricating the pyroelectric cell with a strip form. The strip pyroelectric cell with a high-narrow cross section is able to greatly absorb thermal energy via the side walls of the strips, thereby inducing lateral temperature gradients and increasing temperature variation rates in a thicker pyroelectric cell. Both simulation and experimentation show that the strip pyroelectric cell improves the electrical outputs of pyroelectric cells and enhances the efficiency of pyroelectric harvesters. The strip-type pyroelectric cell has a larger temperature variation when compared to the trenched electrode and the original type, by about 1.9 and 2.4 times, respectively. The measured electrical output of the strip type demonstrates a conspicuous increase in stored energy as compared to the trenched electrode and the original type, by of about 15.6 and 19.8 times, respectively. PMID:26999134

  10. A Strip Cell in Pyroelectric Devices

    PubMed Central

    Siao, An-Shen; Chao, Ching-Kong; Hsiao, Chun-Ching

    2016-01-01

    The pyroelectric effect affords the opportunity to convert temporal temperature fluctuations into usable electrical energy in order to develop abundantly available waste heat. A strip pyroelectric cell, used to enhance temperature variation rates by lateral temperature gradients and to reduce cell capacitance to further promote the induced voltage, is described as a means of improving pyroelectric energy transformation. A precision dicing saw was successfully applied in fabricating the pyroelectric cell with a strip form. The strip pyroelectric cell with a high-narrow cross section is able to greatly absorb thermal energy via the side walls of the strips, thereby inducing lateral temperature gradients and increasing temperature variation rates in a thicker pyroelectric cell. Both simulation and experimentation show that the strip pyroelectric cell improves the electrical outputs of pyroelectric cells and enhances the efficiency of pyroelectric harvesters. The strip-type pyroelectric cell has a larger temperature variation when compared to the trenched electrode and the original type, by about 1.9 and 2.4 times, respectively. The measured electrical output of the strip type demonstrates a conspicuous increase in stored energy as compared to the trenched electrode and the original type, by of about 15.6 and 19.8 times, respectively. PMID:26999134

  11. Transfusion and blood donation in comic strips.

    PubMed

    Lefrère, Jean-Jacques; Danic, Bruno

    2013-07-01

    The representation of blood transfusion and donation of blood in the comic strip has never been studied. The comic strip, which is a relatively recent art, emerged in the 19th century before becoming a mass medium during the 20th century. We have sought, by calling on collectors and using the resources of Internet, comic strips devoted, wholly or in part, to the themes of transfusion and blood donation. We present some of them here in chronologic order, indicating the title, country of origin, year of publication, and names of authors. The theme of the superhero using transfusion to transmit his virtues or his powers is repeated throughout the 20th century in North American comic strips. More recently, comic strips have been conceived from the outset with a promotional aim. They perpetuate positive images and are directed toward a young readership, wielding humor to reduce the fear of venipuncture. Few comic strips denounce the abuse of the commercialization of products derived from the human body. The image of transfusion and blood donation given by the comic strips is not to be underestimated because their readership is primarily children, some of whom will become blood donors. Furthermore, if some readers are transfused during their lives, the impact of a memory more or less conscious of these childhood readings may resurface, both in hopes and in fears. PMID:23643789

  12. NREL National Wind Technology Center (NWTC): M2 Tower; Boulder, Colorado (Data)

    DOE Data Explorer

    Jager, D.; Andreas, A.

    1996-09-24

    The National Wind Technology Center (NWTC), located at the foot of the Rocky Mountains near Boulder, Colorado, is a world-class research facility managed by NREL for the U.S. Department of Energy. NWTC researchers work with members of the wind energy industry to advance wind power technologies that lower the cost of wind energy through research and development of state-of-the-art wind turbine designs. NREL's Measurement and Instrument Data Center provides data from NWTC's M2 tower which are derived from instruments mounted on or near an 82 meter (270 foot) meteorological tower located at the western edge of the NWTC site and about 11 km (7 miles) west of Broomfield, and approximately 8 km (5 miles) south of Boulder, Colorado. The data represent the mean value of readings taken every two seconds and averaged over one minute. The wind speed and direction are measured at six heights on the tower and air temperature is measured at three heights. The dew point temperature, relative humidity, barometric pressure, totalized liquid precipitation, and global solar radiation are also available.

  13. Relationship between evapotranspiration and precipitation pulses in a semiarid rangeland estimated by moisture flux towers and MODIS vegetation indices

    USGS Publications Warehouse

    Nagler, P.L.; Glenn, E.P.; Kim, H.; Emmerich, W.; Scott, R.L.; Huxman, T. E.; Huete, A.R.

    2007-01-01

    We used moisture Bowen ratio flux tower data and the enhanced vegetation index (EVI) from the moderate resolution imaging spectrometer (MODIS) on the Terra satellite to measure and scale evapotranspiration (ET) over sparsely vegetated grassland and shrubland sites in a semiarid watershed in southeastern Arizona from 2000 to 2004. The grassland tower site had higher mean annual ET (336 mm yr-1) than the shrubland tower site (266 mm yr-1) (P<0.001). ET measured at the individual tower sites was strongly correlated with EVI (r=0.80-0.94). ET was moderately correlated with precipitation (P), and only weakly correlated with net radiation or air temperature. The strong correlation between ET and EVI, as opposed to the moderate correlation with rainfall, suggests that transpiration (T) is the dominant process controlling ET at these sites. ET could be adequately predicted from EVI and P across seasons and tower sites (r2 = 0.74) by a single multiple regression equation. The regression equation relating ET to EVI and P was used to scale ET over 25 km2 areas of grassland and shrubland around each tower site. Over the study, ratios of T to ET ranged from 0.75 to 1.0. Winter rains stimulated spring ET, and a large rain event in fall, 2000, stimulated ET above T through the following year, indicating that winter rain stored in the soil profile can be an important component of the plants' water budget during the warm season in this ecosystem. We conclude that remotely sensed vegetation indices can be used to scale ground measurements of ET over larger landscape units in semiarid ranglelands, and that the vegetation communities in this landscape effectively harvest the available precipitation over a period of years, even though precipitation patterns are variably seasonally and interannually. ?? 2007 Elsevier Ltd. All rights reserved.

  14. Relationship Between Evapotranspiration and Precipitation Pulses in a Semiarid Rangeland Estimated by Moisture Flux Towers and MODIS Vegetation Indices

    NASA Astrophysics Data System (ADS)

    Nagler, P. L.; Glenn, E. P.; Kim, H.; Emmerich, W. E.; Scott, R. L.; Huxman, T. E.; Huete, A. R.

    2007-05-01

    We used moisture Bowen ratio flux tower data and the Enhanced Vegetation Index (EVI) from the Moderate Resolution Imaging Spectrometer (MODIS) on the Terra satellite to measure and scale evapotranspiration (ET) over sparsely vegetated grassland and shrubland sites in a semiarid watershed near the Upper San Pedro River in southeastern Arizona from 2000 to 2004. The grassland tower site had higher mean annual ET (336 mm yr-1) than the shrubland tower site (266 mm yr-1) (P<0.001). ET measured at the individual tower sites was strongly correlated with EVI (r = 0.80 - 0.94). ET was moderately correlated with precipitation (P), and only weakly correlated with net radiation or air temperature. The strong correlation between ET and EVI, as opposed to the moderate correlation with rainfall, suggests that transpiration (T) is the dominant process controlling ET at these sites. ET could be adequately predicted from EVI and P across seasons and tower sites (r2 = 0.74) by a single multiple regression equation. The regression equation relating ET to EVI and P was used to scale ET over 25 km2 areas of grassland and shrubland around each tower site. Over the study, ratios of T to ET ranged from 0.75 to 1.0. Winter rains stimulated spring ET, and a large rain event in fall, 2000, stimulated ET above T through the following year, indicating that winter rain stored in the soil profile can be an important component of the plants' water budget during the warm season in this ecosystem. We conclude that remotely sensed vegetation indices can be used to scale ground measurements of ET over larger landscape units in semiarid rangelands, and that the vegetation communities in this landscape effectively harvest the available precipitation over a period of years, even though precipitation patterns are variably seasonally and interannually.

  15. Optical sampling of the flux tower footprint

    NASA Astrophysics Data System (ADS)

    Gamon, J. A.

    2015-03-01

    The purpose of this review is to address the reasons and methods for conducting optical remote sensing within the flux tower footprint. Fundamental principles and conclusions gleaned from over two decades of proximal remote sensing at flux tower sites are reviewed. An organizing framework is the light-use efficiency (LUE) model, both because it is widely used, and because it provides a useful theoretical construct for integrating optical remote sensing with flux measurements. Multiple ways of driving this model, ranging from meteorological measurements to remote sensing, have emerged in recent years, making it a convenient conceptual framework for comparative experimental studies. New interpretations of established optical sampling methods, including the Photochemical Reflectance Index (PRI) and Solar-Induced Fluorescence (SIF), are discussed within the context of the LUE model. Multi-scale analysis across temporal and spatial axes is a central theme, because such scaling can provide links between ecophysiological mechanisms detectable at the level of individual organisms and broad patterns emerging at larger scales, enabling evaluation of emergent properties and extrapolation to the flux footprint and beyond. Proper analysis of sampling scale requires an awareness of sampling context that is often essential to the proper interpretation of optical signals. Additionally, the concept of optical types, vegetation exhibiting contrasting optical behavior in time and space, is explored as a way to frame our understanding of the controls on surface-atmosphere fluxes. Complementary NDVI and PRI patterns across ecosystems are offered as an example of this hypothesis, with the LUE model and light-response curve providing an integrating framework. We conclude that experimental approaches allowing systematic exploration of plant optical behavior in the context of the flux tower network provides a unique way to improve our understanding of environmental constraints and

  16. Retractable spiked barrier strip for law enforcement

    SciTech Connect

    Marts, D.J.; Barker, S.G.

    1995-03-01

    The Idaho National Engineering Laboratory has designed an laboratory tested a prototype retractable spiked barrier strip for law enforcement. The proposed system, which is ready for controlled field testing, expands the functionality of existing spiked barrier strips. A retractable barrier strip, one that can place the spikes in either the active (vertical) or passive (horizontal) position, would allow law enforcement personnel to lay the unobtrusive strip across a road far in advance of a fleeing vehicle. No damage occurs to passing vehicles until the spikes are activated, and that can be done from a safe distance and at a strategic location when the offending vehicle is close to the strip. The concept also allows the strips to be place safely across several roadways that are potential paths of a fleeing vehicle. Since they are not activated until needed, they are harmless to nonoffending vehicles. The laboratory tests conducted on the system indicate that it will puncture tires only when the spikes are rotated to the active position and is safe to travel over when the spikes are in the down position. The strip itself will not cause instability to a vehicle driving over it, nor is the strip disturbed or adversely affected by vehicles driving over it. The spikes can be quickly rotated between the active (vertical) and passive (horizontal) position. However, the laboratory tests have only demonstrated that the retractable spiked barrier strip can perform its intended function in a laboratory environment. Field tests are needed to finalize the design and develop the system into a functional law enforcement tool.

  17. Conversion Tower for Dispatchable Solar Power: High-Efficiency Solar-Electric Conversion Power Tower

    SciTech Connect

    2012-01-11

    HEATS Project: Abengoa Solar is developing a high-efficiency solar-electric conversion tower to enable low-cost, fully dispatchable solar energy generation. Abengoa’s conversion tower utilizes new system architecture and a two-phase thermal energy storage media with an efficient supercritical carbon dioxide (CO2) power cycle. The company is using a high-temperature heat-transfer fluid with a phase change in between its hot and cold operating temperature. The fluid serves as a heat storage material and is cheaper and more efficient than conventional heat-storage materials, like molten salt. It also allows the use of a high heat flux solar receiver, advanced high thermal energy density storage, and more efficient power cycles.

  18. High energy H- ion transport and stripping

    SciTech Connect

    Chou, W.; /Fermilab

    2005-05-01

    During the Proton Driver design study based on an 8 GeV superconducting RF H{sup -} linac, a major concern is the feasibility of transport and injection of high energy H{sup -} ions because the energy of H{sup -} beam would be an order of magnitude higher than the existing ones. This paper will focus on two key technical issues: (1) stripping losses during transport (including stripping by blackbody radiation, magnetic field and residual gases); (2) stripping efficiency of carbon foil during injection.

  19. Instabilities and Solitons in Minimal Strips

    NASA Astrophysics Data System (ADS)

    Machon, Thomas; Alexander, Gareth P.; Goldstein, Raymond E.; Pesci, Adriana I.

    2016-07-01

    We show that highly twisted minimal strips can undergo a nonsingular transition, unlike the singular transitions seen in the Möbius strip and the catenoid. If the strip is nonorientable, this transition is topologically frustrated, and the resulting surface contains a helicoidal defect. Through a controlled analytic approximation, the system can be mapped onto a scalar ϕ4 theory on a nonorientable line bundle over the circle, where the defect becomes a topologically protected kink soliton or domain wall, thus establishing their existence in minimal surfaces. Demonstrations with soap films confirm these results and show how the position of the defect can be controlled through boundary deformation.

  20. Instabilities and Solitons in Minimal Strips.

    PubMed

    Machon, Thomas; Alexander, Gareth P; Goldstein, Raymond E; Pesci, Adriana I

    2016-07-01

    We show that highly twisted minimal strips can undergo a nonsingular transition, unlike the singular transitions seen in the Möbius strip and the catenoid. If the strip is nonorientable, this transition is topologically frustrated, and the resulting surface contains a helicoidal defect. Through a controlled analytic approximation, the system can be mapped onto a scalar ϕ^{4} theory on a nonorientable line bundle over the circle, where the defect becomes a topologically protected kink soliton or domain wall, thus establishing their existence in minimal surfaces. Demonstrations with soap films confirm these results and show how the position of the defect can be controlled through boundary deformation. PMID:27419593