Science.gov

Sample records for air supply duct

  1. Apparatus for supplying conditioned air at a substantially constant temperature and humidity

    NASA Technical Reports Server (NTRS)

    Obler, H. D. (Inventor)

    1980-01-01

    The apparatus includes a supply duct coupled to a source of supply air for carrying the supply air therethrough. A return duct is coupled to the supply duct for carrying return conditioned air therethrough. A temperature reducing device is coupled to the supply duct for decreasing the temperature of the supply and return conditioned air. A by-pass duct is coupled to the supply duct for selectively directing portions of the supply and return conditioned air around the temperature reducing device. Another by-pass duct is coupled to the return duct for selectively directing portions of the return conditioned air around the supply duct and the temperature reduction device. Controller devices selectively control the flow and amount of mixing of the supply and return conditioned air.

  2. Advanced Strategy Guideline: Air Distribution Basics and Duct Design

    SciTech Connect

    Burdick, A.

    2011-12-01

    This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amount of conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

  3. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Induction systems ducts and air duct... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air duct systems. (a) Each induction system duct upstream of the...

  4. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Induction systems ducts and air duct systems. 29.1103 Section 29.1103 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Induction System § 29.1103 Induction systems ducts and air...

  5. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... between the air duct source and the airplane unit served by the air. (e) Each auxiliary power unit... other compartment or area of the airplane in which a hazard would be created resulting from the entry...

  6. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... between the air duct source and the airplane unit served by the air. (e) Each auxiliary power unit... other compartment or area of the airplane in which a hazard would be created resulting from the entry...

  7. Study of Relationship Between the Blood Supply of the Extrahepatic Bile Duct and Duct Supply Branches from Gastroduodenal Artery on Imaging and Anatomy

    PubMed Central

    Dai, Jie; Wu, Xiao-Feng; Yang, Chun; Li, Hong-Jun; Chen, Ya-Liang; Liu, Guo-Zhen; Song, Yi-Zhi; Wu, Huan-Huan; Ding, Jin-Li; Li, Ning

    2015-01-01

    Background: Liver transplantation has become the treatment of choice for patients with end-stage acute or chronic hepatic disease. Bile duct complications are common events after liver transplantation. The aim of this study was to evaluate the blood supply of the human bile duct and identify the underlying mechanisms of bile duct complications after liver transplantation. Methods: The duct supply branches from gastroduodenal artery and blood supply of extrahepatic bile duct system were re-evaluated through selective hepatic angiography from 600 patients. In addition, 33 cadavers were injected with latex casting material into the common hepatic artery, then the extrahepatic bile duct and the branches from the common hepatic artery were carefully dissected to visualize the gastroduodenal artery and its branching to the extrahepatic bile duct. Results: The bile duct artery arose from the branch of the gastroduodenal artery in 8.1% (49/600). Of these 49 individuals, the bile duct artery was supplied by the gastroduodenal artery (61.22%, 30/49), the proper hepatic artery (14.29%, 7/49), or both the gastroduodenal artery and the proper hepatic artery (24.49%, 12/49). In our study of 33 cadavers, the percentage that the bile duct artery arose from the gastroduodenal artery was 27.27%. The blood supply to the bile extrahepatic bile ducts was divided into different segments and formed longitudinal and arterial network anastomosed on the walls of the duct. Conclusions: There is a close relationship between the duct supply branches from gastroduodenal artery and the blood supplying patterns of the extrahepatic bile duct system. In liver transplant surgery, the initial part of the gastroduodenal artery is preferred to be preserved in the donor liver. It is of great significance to improve the success rate of operation and reduce complications. PMID:25635427

  8. ANALYSIS OF MEASUREMENT UNCERTAINTIES IN THE NULLING TEST FOR AIR LEAKAGE FROM RESIDENTIAL DUCTS.

    SciTech Connect

    ANDREWS,J.W.

    2001-04-01

    An analysis of measurement uncertainties in a recently proposed method of measuring air leakage in residential duct systems has been carried out. The uncertainties in supply and return leakage rates are expressed in terms of the value of the envelope leakage flow coefficient and the uncertainties in measured pressures and air flow rates. Results of the analysis are compared with data published by two research groups.

  9. Air supply distributor for fireplaces

    SciTech Connect

    Eberhardt, H.A.

    1984-09-18

    An air supply distributor for fireplaces having an opening in the hearth for the supply of relatively cold air is used in combination with means, such as a log holder or grate, for supporting combustible products and comprises a pair of side walls and a top cover. The distributor is adapted to be positioned under the log holder or grate to overlie the hearth opening so that relatively cold air passing through the hearth opening is directed toward the front opening of the fireplace from which it passes to the fire for supporting combustion thereof thereby minimizing the amount of air drawn from the room.

  10. AIR DUCTS STAND NEXT TO (AND OUTSIDE OF) REACTOR CABINET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    AIR DUCTS STAND NEXT TO (AND OUTSIDE OF) REACTOR CABINET AT THE SOUTHWEST AND NORTHEAST CORNERS OF THE REACTOR'S THERMAL SHIELD. THEY WILL BE ENVELOPED IN BIOLOGICAL CONCRETE SHIELD. IN THE SUB-BASEMENT, THE TWO DUCTS WILL JOIN TOGETHER AND EXIT THE BUILDING TO THE FAN HOUSE. CAMERA FACING NORTH. INL NEGATIVE NO. 1625. Unknown Photographer, 3/6/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  11. Low-noise flow valve for air ducts

    NASA Technical Reports Server (NTRS)

    Gallo, E. A.

    1970-01-01

    Valve assembly controls air flow from feeder into main duct, with minimum of turbulence, friction, pressure differential, and noise. Valve consists of damper, deflector, and spring. Streamlining of damper and deflector merges flow smoothly, while spring keeps damper and deflector in contact and eliminates valve chatter and damping vibrations.

  12. Protective supplied breathing air garment

    DOEpatents

    Childers, Edward L.; von Hortenau, Erik F.

    1984-07-10

    A breathing air garment for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap.

  13. Protective supplied breathing air garment

    DOEpatents

    Childers, E.L.; Hortenau, E.F. von.

    1984-07-10

    A breathing air garment is disclosed for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap. 17 figs.

  14. Cooling air recycling for gas turbine transition duct end frame and related method

    DOEpatents

    Cromer, Robert Harold; Bechtel, William Theodore; Sutcu, Maz

    2002-01-01

    A method of cooling a transition duct end frame in a gas turbine includes the steps of a) directing cooling air into the end frame from a region external of the transition duct and the impingement cooling sleeve; and b) redirecting the cooling air from the end frame into the annulus between the transition duct and the impingement cooling sleeve.

  15. The influence of air duct geometry on air jet direction in aircraft cabin ventilated by mixing ventilation.

    NASA Astrophysics Data System (ADS)

    Fišer, J.; Jícha, M.

    2013-04-01

    The paper deals with instigation of influence of air duct geometry on air jet direction in aircraft cabin ventilated by mixing ventilation. CFD approach was used for investigation and model geometry was based on small aircraft cabin mock-up geometry. Model was also equipped by nine seats and five manikins that represent passengers. The air jet direction was observed for selected ambient environment parameters and several types of air duct geometry and influence of main air duct geometry on jets direction is discussed. The model was created in StarCCM+ ver. 6.04.014 software and polyhedral mesh was used.

  16. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the auxiliary power unit must be capable of resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not...

  17. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the auxiliary power unit must be capable of resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not...

  18. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not absorb or trap hazardous quantities of flammable...

  19. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not absorb or trap hazardous quantities of flammable...

  20. 14 CFR 25.1103 - Induction system ducts and air duct systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the auxiliary power unit must be capable of resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not...

  1. 14 CFR 29.1103 - Induction systems ducts and air duct systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... resisting the maximum heat conditions likely to occur. (f) Each auxiliary power unit induction system duct must be constructed of materials that will not absorb or trap hazardous quantities of flammable...

  2. Fluid-bed air-supply system

    DOEpatents

    Zielinski, Edward A.; Comparato, Joseph R.

    1979-01-01

    The air-supply system for a fluidized-bed furnace includes two air conduits for the same combustion zone. The conduits feed separate sets of holes in a distributor plate through which fluidizing air flows to reach the bed. During normal operation, only one conduit and set of holes is used, but the second conduit and set of holes is employed during start-up.

  3. Protective supplied-breathing-air garment

    DOEpatents

    Childers, E.L.; von Hortenau, E.F.

    1982-05-28

    A breathing-air garment for isolating a wearer from hostile environments containing toxins or irritants is disclosed. The garment includes a suit and a separate head-protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air-delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air-delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit sealed with an adhesive sealing flap.

  4. 46 CFR 197.432 - Surface-supplied air diving.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Surface-supplied air diving. 197.432 Section 197.432...-supplied air diving. The diving supervisor shall insure that— (a) Surface-supplied air diving is conducted... space; and (f) The surface-supplied air diver has the equipment required by § 197.346 (b) or (d)....

  5. 29 CFR 1910.425 - Surface-supplied air diving.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 5 2012-07-01 2012-07-01 false Surface-supplied air diving. 1910.425 Section 1910.425... Procedures § 1910.425 Surface-supplied air diving. (a) General. Employers engaged in surface-supplied air...-supplied air diving shall not be conducted at depths deeper than 190 fsw, except that dives with...

  6. 42 CFR 84.130 - Supplied-air respirators; description.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Supplied-air respirators; description. 84.130... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.130 Supplied-air respirators; description. Supplied-air respirators, including all...

  7. 29 CFR 1910.425 - Surface-supplied air diving.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 5 2013-07-01 2013-07-01 false Surface-supplied air diving. 1910.425 Section 1910.425... Procedures § 1910.425 Surface-supplied air diving. (a) General. Employers engaged in surface-supplied air...-supplied air diving shall not be conducted at depths deeper than 190 fsw, except that dives with...

  8. 42 CFR 84.130 - Supplied-air respirators; description.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Supplied-air respirators; description. 84.130... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.130 Supplied-air respirators; description. Supplied-air respirators, including all...

  9. 46 CFR 197.432 - Surface-supplied air diving.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Surface-supplied air diving. 197.432 Section 197.432...-supplied air diving. The diving supervisor shall insure that— (a) Surface-supplied air diving is conducted... space; and (f) The surface-supplied air diver has the equipment required by § 197.346 (b) or (d)....

  10. 42 CFR 84.130 - Supplied-air respirators; description.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Supplied-air respirators; description. 84.130... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.130 Supplied-air respirators; description. Supplied-air respirators, including all...

  11. 42 CFR 84.130 - Supplied-air respirators; description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Supplied-air respirators; description. 84.130... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.130 Supplied-air respirators; description. Supplied-air respirators, including all...

  12. Experimental study on the flame behaviors of premixed methane/air mixture in horizontal rectangular ducts

    NASA Astrophysics Data System (ADS)

    Chen, Dongliang; Sun, Jinhua; Chen, Sining; Liu, Yi; Chu, Guanquan

    2007-01-01

    In order to explore the flame propagation characteristics and tulip flame formation mechanism of premixed methane/air mixture in horizontal rectangular ducts, the techniques of Schlieren and high-speed video camera are used to study the flame behaviors of the premixed gases in a closed duct and opened one respectively, and the propagation characteristics in both cases and the formation mechanism of the tulip flame are analyzed. The results show that, the propagation flame in a closed duct is prior to form a tulip flame structure than that in an opened duct, and the tulip flame structure formation in a closed duct is related to the flame propagation velocity decrease. The sharp decrease of the flame propagation velocity is one of the reasons to the tulip flame formation, and the decrease of the flame propagation velocity is due to the decrease of the burned product flow velocity mainly.

  13. Should You Have the Air Ducts in Your Home Cleaned?

    MedlinePlus

    ... heat exchangers) may improve the efficiency of your system, resulting in a longer operating life, as well as some energy and maintenance ... spraying or otherwise introducing these materials into the operating duct system may cause much of the material to be ...

  14. Particle deposition in ventilation ducts

    SciTech Connect

    Sippola, Mark R.

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 {micro}m were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on

  15. 42 CFR 84.142 - Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators; minimum requirements. 84.142 Section 84.142 Public....142 Air supply source; hand-operated or motor driven air blowers; Type A supplied-air...

  16. 42 CFR 84.142 - Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators; minimum requirements. 84.142 Section 84.142 Public....142 Air supply source; hand-operated or motor driven air blowers; Type A supplied-air...

  17. 42 CFR 84.142 - Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators; minimum requirements. 84.142 Section 84.142 Public....142 Air supply source; hand-operated or motor driven air blowers; Type A supplied-air...

  18. 42 CFR 84.142 - Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators; minimum requirements. 84.142 Section 84.142 Public....142 Air supply source; hand-operated or motor driven air blowers; Type A supplied-air...

  19. Workplace protection factors--supplied air hood.

    PubMed

    Nelson, T J; Wheeler, T H; Mustard, T S

    2001-01-01

    Several organizations list assigned protection factors. For supplied air hoods, the value of the assigned protection factors varies from <10 to 2,000 depending on the organization. Workplace protection factors (WPFs) of a supplied air hood were measured during aircraft sanding and painting operations on several types of aircraft to evaluate whether the American National Standard Z88.2 (1992) assigned protection factor of 1,000 was realistic. The primary contaminant during these activities is strontium chromate. Samples collected inside the hood show that employees during sanding and painting operations were not exposed to strontium. The respirator performed adequately. This study is consistent with other simulated and WPF studies in that the ANSI Z88.2 WPF of 1,000 is supported. PMID:11258874

  20. Air-sea interaction and spatial variability of the surface evaporation duct in a coastal environment

    NASA Astrophysics Data System (ADS)

    Brooks, Ian M.

    Aircraft observations are presented of the horizontal variability in the depth of the surface evaporation duct and the relationship with the mesoscale structure of air-sea interaction processes. The 2-dimensional fields of near-surface wind, stress, wind-stress curl, air and sea-surface temperature are measured directly for flow around a headland. The sea surface temperature field indicates cold upwelling driven by the wind-stress curl. Boundary-layer stability responds rapidly to the spatial changes in surface temperature. These changes result in modification of the evaporation duct, which decreases significantly in depth over the cooler upwelling water.

  1. Development of an ultrasonic airflow measurement device for ducted air.

    PubMed

    Raine, Andrew B; Aslam, Nauman; Underwood, Christopher P; Danaher, Sean

    2015-01-01

    In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a "V" shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers. PMID:25954952

  2. Development of an Ultrasonic Airflow Measurement Device for Ducted Air

    PubMed Central

    Raine, Andrew B.; Aslam, Nauman; Underwood, Christopher P.; Danaher, Sean

    2015-01-01

    In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a “V” shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers. PMID:25954952

  3. FIELD EVALUATION OF IMPROVED METHODS FOR MEASURING THE AIR LEAKAGE OF DUCT SYSTEMS UNDER NORMAL OPERATING CONDITIONS IN 51 HOMES

    SciTech Connect

    Paul W. Francisco; Larry Palmiter; Erin Kruse; Bob Davis

    2003-10-18

    Duct leakage in forced-air distribution systems has been recognized for years as a major source of energy losses in residential buildings. Unfortunately, the distribution of leakage across homes is far from uniform, and measuring duct leakage under normal operating conditions has proven to be difficult. Recently, two new methods for estimating duct leakage at normal operating conditions have been devised. These are called the nulling test and the Delta-Q test. Small exploratory studies have been done to evaluate these tests, but previously no large-scale study on a broad variety of homes has been performed to determine the accuracy of these new methods in the field against an independent benchmark of leakage. This sort of study is important because it is difficult in a laboratory setting to replicate the range of leakage types found in real homes. This report presents the results of a study on 51 homes to evaluate these new methods relative to an independent benchmark and a method that is currently used. An evaluation of the benchmark procedure found that it worked very well for supply-side leakage measurements, but not as well on the return side. The nulling test was found to perform well, as long as wind effects were minimal. Unfortunately, the time and difficulty of setup can be prohibitive, and it is likely that this method will not be practical for general use by contractors except in homes with no return ducts. The Delta-Q test was found to have a bias resulting in overprediction of the leakage, which qualitatively confirms the results of previous laboratory, simulation, and small-scale field studies. On average the bias was only a few percent of the air handler flow, but in about 20% of the homes the bias was large. A primary flaw with the Delta-Q test is the assumption that the pressure between the ducts and the house remain constant during the test, as this assumption does not hold true. Various modifications to the Delta-Q method were evaluated as

  4. 46 CFR 197.432 - Surface-supplied air diving.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Surface-supplied air diving. 197.432 Section 197.432... STANDARDS GENERAL PROVISIONS Commercial Diving Operations Specific Diving Mode Procedures § 197.432 Surface-supplied air diving. The diving supervisor shall insure that— (a) Surface-supplied air diving is...

  5. 46 CFR 197.432 - Surface-supplied air diving.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Surface-supplied air diving. 197.432 Section 197.432... STANDARDS GENERAL PROVISIONS Commercial Diving Operations Specific Diving Mode Procedures § 197.432 Surface-supplied air diving. The diving supervisor shall insure that— (a) Surface-supplied air diving is...

  6. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    SciTech Connect

    Rudd, A.; Prahl, D.

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  7. Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

    SciTech Connect

    Rudd, A.; Prahl, D.

    2014-12-01

    IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

  8. Advanced Strategy Guideline. Air Distribution Basics and Duct Design

    SciTech Connect

    Burdick, Arlan

    2011-12-01

    This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings.

  9. 29 CFR 1910.425 - Surface-supplied air diving.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 5 2011-07-01 2011-07-01 false Surface-supplied air diving. 1910.425 Section 1910.425..., DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Commercial Diving Operations Specific Operations Procedures § 1910.425 Surface-supplied air diving. (a) General. Employers engaged in surface-supplied...

  10. 29 CFR 1910.425 - Surface-supplied air diving.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Surface-supplied air diving. 1910.425 Section 1910.425..., DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Commercial Diving Operations Specific Operations Procedures § 1910.425 Surface-supplied air diving. (a) General. Employers engaged in surface-supplied...

  11. Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

    SciTech Connect

    Shapiro, Carl; Aldrich, Robb; Arena, Lois

    2012-07-01

    This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

  12. Modeling particle loss in ventilation ducts

    SciTech Connect

    Sippola, Mark R.; Nazaroff, William W.

    2003-04-01

    Empirical equations were developed and applied to predict losses of 0.01-100 {micro}m airborne particles making a single pass through 120 different ventilation duct runs typical of those found in mid-sized office buildings. For all duct runs, losses were negligible for submicron particles and nearly complete for particles larger than 50 {micro}m. The 50th percentile cut-point diameters were 15 {micro}m in supply runs and 25 {micro}m in return runs. Losses in supply duct runs were higher than in return duct runs, mostly because internal insulation was present in portions of supply duct runs, but absent from return duct runs. Single-pass equations for particle loss in duct runs were combined with models for predicting ventilation system filtration efficiency and particle deposition to indoor surfaces to evaluate the fates of particles of indoor and outdoor origin in an archetypal mechanically ventilated building. Results suggest that duct losses are a minor influence for determining indoor concentrations for most particle sizes. Losses in ducts were of a comparable magnitude to indoor surface losses for most particle sizes. For outdoor air drawn into an unfiltered ventilation system, most particles smaller than 1 {micro}m are exhausted from the building. Large particles deposit within the building, mostly in supply ducts or on indoor surfaces. When filters are present, most particles are either filtered or exhausted. The fates of particles generated indoors follow similar trends as outdoor particles drawn into the building.

  13. Dual fan, dual-duct system meets air quality, energy-efficiency needs

    SciTech Connect

    Schuler, M.

    1996-03-01

    Canada`s Space Centre in Saint-Hubert Quebec is a 300,000 ft{sup 2} (27,871 m{sup 2}) complex that houses the headquarters of the Canadian Space Agency, the Canadian Astronaut Training Centre, mission ground control installations, research facilities, offices and the required support facilities. A comfortable, pleasant research environment was a primary concern for the Space Centre, given its elite clientele. The objectives were high indoor-air quality, design flexibility, energy efficiency and low capital costs. Dual duct systems which are the heart of the mechanical concept allowed the designers to meet these objectives. The Space Centre`s offices, laboratories and conference center are all served by dual-duct systems. All operate using an air economizer cycle. Gas boilers provide them with hot water for heating and steam for humidification while centrifugal chillers provide chilled water for cooling. This article describes the design.

  14. SENSITIVITY OF THE HOUSE PRESSURE TEST FOR DUCT LEAKAGE TO VARIATIONS IN THE DISTRIBUTION OF AIR LEAKAGE IN THE HOUSE ENVELOPE

    SciTech Connect

    ANDREWS,J.W.

    1998-12-01

    The house pressure test for air leakage in ducts calculates the signed difference between the supply and return leakage from the response of the air pressure in the house to operation of the system fan. The currently accepted version of this calculation was based on particular assumptions about how the house envelope leakage is distributed between the walls, ceiling, and floor. This report generalizes the equation to account for an arbitrary distribution of envelope leakage. It concludes that the currently accepted equation is usually accurate to within {+-}5%, but in a small proportion of cases the results may diverge by 50% or more.

  15. Sensitivity of the house pressure test for duct leakage to variations in the distribution of air leakage in the house envelope

    SciTech Connect

    Andrews, J.W.

    1998-12-01

    The house pressure test for air leakage in ducts calculates the signed difference between the supply and return leakage from the response of the air pressure in the house to operation of the system fan. The currently accepted version of this calculation was based on particular assumptions about how the house envelope leakage is distributed between the walls, ceiling, and floor. This report generalizes the equation to account for an arbitrary distribution of envelope leakage. It concludes that the currently accepted equation is usually accurate to within {+-}5%, but in a small proportion of cases the results may diverge by 50% or more.

  16. Numerical simulation of flow in a circular duct fitted with air-jet vortex generators

    NASA Astrophysics Data System (ADS)

    Küpper, Christoph; Henry, Frank S.

    2002-04-01

    Most of the fundamental studies of the use of air-jet vortex generators (AJVGs) have concentrated on their potential ability to inhibit boundary layer separation on aerofoils. However, AJVGs may be of use in controlling or enhancing certain features of internal duct flows. For example, they may be of use in controlling the boundary layer at the entrance to engine air intakes, or as a means of increasing mixing and heat transfer. The objective of this paper is to analyse the flow field in the proximity of an air-jet vortex generator array in a duct by using two local numerical models, i.e. a simple flat plate model and a more geometrically faithful sector model. The sector model mirrors the circular nature of the duct's cross-section and the centre line conditions on the upper boundary. The flow was assumed fully turbulent and was solved using the finite volume, Navier-Stokes Code CFX 4 (CFDS, AEA Technology, Harwell) on a non-orthogonal, body-fitted, grid using the k- turbulence model and standard wall functions. Streamwise, vertical and cross-stream velocity profiles, circulation and peak vorticity decay, peak vorticity paths in cross-stream and streamwise direction, cross-stream vorticity profiles and cross-stream wall shear stress distributions were predicted. Negligible difference in results was observed between the flat plate and the sector model, since the produced vortices were small relative to the duct diameter and close to the surface. The flow field was most enhanced, i.e. maximum thinning of the boundary layer, with a configuration of 30° pitch and 75° skew angle. No significant difference in results could be observed between co- and counter-rotating vortex arrays. Copyright

  17. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    PubMed

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates. PMID:19044163

  18. High-speed Tests of a Ducted Body with Various Air-outlet Openings

    NASA Technical Reports Server (NTRS)

    Becker, John V.; Baals, Donald D.

    1942-01-01

    Test of a ducted body with Internal flow were made in the 8-foot high-speed wind tunnel for the purpose of studying the effects on external drag and an critical speed of the addition of efficient inlet and outlet openings to a basic streamline shape. Drag tests of a 13.6- inch-diameter streamline body of fineness ratio 6.14 were made at Mach numbers ranging from 0.20 to 0.75. The model was centrally mounted on a 9-percent-thick airfoil and was designed to have an efficient airfoil-body juncture and a high critical speed. An air inlet at the nose and various outlets at the tail were added: drag and internal-flow data were obtained over the given speed range. The critical speed of the ducted bodies was found to be as high as that of the streamline body. The external - drag with air flow through the body did not exceed the drag of the basic streamline shape. No appreciable variation in the efficiency of the diffuser section of the internal duct occurred throughout the Mach number range of the tests.

  19. 29 CFR 1926.1085 - Surface-supplied air diving.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Surface-supplied air diving. 1926.1085 Section 1926.1085..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Diving Specific Operations Procedures § 1926.1085 Surface-supplied air diving. Note: The requirements applicable to construction...

  20. 29 CFR 1926.1085 - Surface-supplied air diving.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 8 2011-07-01 2011-07-01 false Surface-supplied air diving. 1926.1085 Section 1926.1085..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Diving Specific Operations Procedures § 1926.1085 Surface-supplied air diving. Note: The requirements applicable to construction...

  1. 29 CFR 1926.1085 - Surface-supplied air diving.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 8 2012-07-01 2012-07-01 false Surface-supplied air diving. 1926.1085 Section 1926.1085 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... Procedures § 1926.1085 Surface-supplied air diving. Note: The requirements applicable to construction...

  2. 29 CFR 1926.1085 - Surface-supplied air diving.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 8 2013-07-01 2013-07-01 false Surface-supplied air diving. 1926.1085 Section 1926.1085 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION... Procedures § 1926.1085 Surface-supplied air diving. Note: The requirements applicable to construction...

  3. 29 CFR 1926.1085 - Surface-supplied air diving.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Surface-supplied air diving. 1926.1085 Section 1926.1085..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Diving Specific Operations Procedures § 1926.1085 Surface-supplied air diving. Note: The requirements applicable to construction...

  4. Evaluation of mixing downstream of tees in duct systems with respect to single point representative air sampling.

    PubMed

    Kim, Taehong; O'Neal, Dennis L; Ortiz, Carlos

    2006-09-01

    Air duct systems in nuclear facilities must be monitored with continuous sampling in case of an accidental release of airborne radionuclides. The purpose of this work is to identify the air sampling locations where the velocity and contaminant concentrations fall below the 20% coefficient of variation required by the American National Standards Institute/Health Physics Society N13.1-1999. Experiments of velocity and tracer gas concentration were conducted on a generic "T" mixing system which included combinations of three sub ducts, one main duct, and air velocities from 0.5 to 2 m s (100 to 400 fpm). The experimental results suggest that turbulent mixing provides the accepted velocity coefficients of variation after 6 hydraulic diameters downstream of the T-junction. About 95% of the cases achieved coefficients of variation below 10% by 6 hydraulic diameters. However, above a velocity ratio (velocity in the sub duct/velocity in the main duct) of 2, velocity profiles were uniform in a shorter distance downstream of the T-junction as the velocity ratio went up. For the tracer gas concentration, the distance needed for the coefficients of variation to drop 20% decreased with increasing velocity ratio due to the sub duct airflow momentum. The results may apply to other duct systems with similar geometries and, ultimately, be a basis for selecting a proper sampling location under the requirements of single point representative sampling. PMID:16891896

  5. Fuel cell stack with passive air supply

    DOEpatents

    Ren, Xiaoming; Gottesfeld, Shimshon

    2006-01-17

    A fuel cell stack has a plurality of polymer electrolyte fuel cells (PEFCs) where each PEFC includes a rectangular membrane electrode assembly (MEA) having a fuel flow field along a first axis and an air flow field along a second axis perpendicular to the first axis, where the fuel flow field is long relative to the air flow field. A cathode air flow field in each PEFC has air flow channels for air flow parallel to the second axis and that directly open to atmospheric air for air diffusion within the channels into contact with the MEA.

  6. Air intake side secondary air supply system for an internal combustion engine

    SciTech Connect

    Kobayashi, H.; Tomobe, N.

    1987-03-10

    This patent describes an air intake side secondary air supply system for an internal combustion engine having a choke valve and a throttle valve in an intake air passage. The system is adapted to supply an air intake side secondary air into an intake air passage downstream of the throttle valve by a control valve and in response to an operating condition of the engine during a cold operation of the engine. The improvement described here comprises means for detecting a no-load operating state of the engine during the cold operation of the engine in which the choke valve is actuated to close the intake air passage, and means for stopping a supply of the air intake side secondary air upon detection of the non-load operating state so as to enrich an air-fuel mixture supplied to the engine.

  7. Simulation Analysis of Air Flow and Turbulence Statistics in a Rib Grit Roughened Duct

    PubMed Central

    Vogiatzis, I. I.; Denizopoulou, A. C.; Ntinas, G. K.; Fragos, V. P.

    2014-01-01

    The implementation of variable artificial roughness patterns on a surface is an effective technique to enhance the rate of heat transfer to fluid flow in the ducts of solar air heaters. Different geometries of roughness elements investigated have demonstrated the pivotal role that vortices and associated turbulence have on the heat transfer characteristics of solar air heater ducts by increasing the convective heat transfer coefficient. In this paper we investigate the two-dimensional, turbulent, unsteady flow around rectangular ribs of variable aspect ratios by directly solving the transient Navier-Stokes and continuity equations using the finite elements method. Flow characteristics and several aspects of turbulent flow are presented and discussed including velocity components and statistics of turbulence. The results reveal the impact that different rib lengths have on the computed mean quantities and turbulence statistics of the flow. The computed turbulence parameters show a clear tendency to diminish downstream with increasing rib length. Furthermore, the applied numerical method is capable of capturing small-scale flow structures resulting from the direct solution of Navier-Stokes and continuity equations. PMID:25057511

  8. 42 CFR 84.142 - Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Air supply source; hand-operated or motor driven air blowers; Type A supplied-air respirators; minimum requirements. 84.142 Section 84.142 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  9. 111. REFRIGERANT CONDENSER TANKS AND AIR INTAKE SUPPLY FAN IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    111. REFRIGERANT CONDENSER TANKS AND AIR INTAKE SUPPLY FAN IN NORTHEAST CORNER OF MECHANICAL EQUIPMENT ROOM (201), LSB (BLDG. 751). PREFILTERS FOR CONDENSERS ON LEFT OF PHOTOGRAPH. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  10. Room-temperature thermal-resistance measurements of new and existing materials for shipboard air-duct systems

    SciTech Connect

    Zarr, R.R.; Somers, T.A.

    1988-10-01

    Thermal resistance measurements of conventional and composite-material insulation for shipboard air duct systems are described. Conventional shipboard air ducts are constructed of metal walls insulated externally with fibrous-glass board. Composite materials are being considered as replacements for these duct walls. Thermal measurements were conducted using the National Bureau of Standards 1-meter Guarded Hot Plate at a mean temperature of 23.9/sup 0/C (75/sup 0/F). Measurements of the fibrous-glass board specimens were within 3% of certified values of NBS SRM 1450a, fibrous-glass board. Measurements of two aramid-fiber honeycomb specimens were approximately one-half the thermal resistance of the fibrous-glass board specimens.

  11. Duct joining system

    DOEpatents

    Proctor, John P.; deKieffer, Robert C.

    2001-01-01

    A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.

  12. Duct Joining System

    DOEpatents

    Proctor, John P.

    2001-02-27

    A duct joining system for providing an air-tight seal and mechanical connection for ducts and fittings is disclosed. The duct joining system includes a flexible gasket affixed to a male end of a duct or fitting. The flexible gasket is affixed at an angle relative to normal of the male end of the duct. The female end of the other duct includes a raised bead in which the flexible gasket is seated when the ducts are properly joined. The angled flexible gasket seated in the raised bead forms an air-tight seal as well as fastens or locks the male end to the female end. Alternatively, when a flexible duct is used, a band clamp with a raised bead is clamped over the female end of the flexible duct and over the male end of a fitting to provide an air tight seal and fastened connection.

  13. High accuracy acoustic relative humidity measurement in duct flow with air.

    PubMed

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments. PMID:22163610

  14. High Accuracy Acoustic Relative Humidity Measurement in Duct Flow with Air

    PubMed Central

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0–12 m/s with an error of ±0.13 m/s, temperature 0–100 °C with an error of ±0.07 °C and relative humidity 0–100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments. PMID:22163610

  15. STS-56 inflight maintenance (IFM) air duct routing on OV-103's middeck

    NASA Technical Reports Server (NTRS)

    1993-01-01

    STS-56 inflight maintenance (IFM) repair on Discovery's, Orbiter Vehicle (OV) 103's, middeck was required to offset overheating problems with one of the onboard experiments -- Detailed Supplementary Objective (DSO) 322, Human lymphocyte locomotion in microgravity. This 'elephant's trunk' fix was rigged from the airlock's air recirculation duct to DSO 322's forward locker location by Commander Kenneth Cameron. The 'elephant's trunk' was fashioned from trash bags and other plastic items to extend an airline to the troubled area. DSO 322 is collecting data on the locomotion and migration of human lymphocytes through intercellular matrix and is testing the rotating wall vessel and the specimen temperature controller. In the background is the port side wall with the side hatch, middeck accomodations rack (MAR), and shuttle orbiter repackaged galley (SORG) visible.

  16. 42 CFR 84.148 - Type C supplied-air respirator, continuous flow class; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.148 Type C supplied-air respirator, continuous... pressure at any point in the supply system exceeds 863 kN/m.2 (125 pounds per square inch gage),...

  17. 42 CFR 84.148 - Type C supplied-air respirator, continuous flow class; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.148 Type C supplied-air respirator, continuous... pressure at any point in the supply system exceeds 863 kN/m.2 (125 pounds per square inch gage),...

  18. 42 CFR 84.148 - Type C supplied-air respirator, continuous flow class; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.148 Type C supplied-air respirator, continuous... pressure at any point in the supply system exceeds 863 kN/m.2 (125 pounds per square inch gage),...

  19. 42 CFR 84.148 - Type C supplied-air respirator, continuous flow class; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.148 Type C supplied-air respirator, continuous... pressure at any point in the supply system exceeds 863 kN/m.2 (125 pounds per square inch gage),...

  20. Sound transmission loss of double plates with an air cavity between them in a rigid duct.

    PubMed

    Kim, Hyun-Sil; Kim, Sang-Ryul; Lee, Seong-Hyun; Seo, Yun-Ho; Ma, Pyung-Sik

    2016-05-01

    In this paper, the sound transmission loss (STL) of thin double plates with an air cavity between them in a rigid duct is considered using an analytical approach. The vibration motion of the plate and sound pressure field are expanded in terms of an infinite series of the modal functions. Under the plane wave condition, a low frequency solution is derived by including the first few symmetric modes. It is determined that the peak frequencies of the double plates coincide with those of each single plate. When the two plates are identical, the STL becomes zero at the natural frequencies of the single plate. However, when the two plates are not identical, the STL is always greater than zero. The location and amplitude of the dips are investigated using an approximate solution when the cavity depth is very small. It is observed that dividing the single plate into two plates with an air cavity in between degrades the STL in the low frequency range, while the equivalent surface mass density is preserved. However, when the cavity depth is not small, the STL of the single plate can be smaller than that of the double plates. PMID:27250128

  1. 29 CFR 1910.425 - Surface-supplied air diving.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-supplied air diving shall not be conducted at depths deeper than 190 fsw, except that dives with bottom times of 30 minutes or less may be conducted to depths of 220 fsw. (2) A decompression chamber shall be... fsw. (3) A bell shall be used for dives with an inwater decompression time greater than 120...

  2. Power supply with air core transformer and seperated power supplies for high dynamic range

    NASA Technical Reports Server (NTRS)

    Chutjian, Ara (Inventor); Aalami, Dean (Inventor); Darrach, Murray (Inventor); Orient, Otto (Inventor)

    2001-01-01

    A power supply for a quadrupole mass spectrometer which operates using an RF signal. The RF signal is controllable via a feedback loop. The feedback loop is from the output, through a comparator, and compared to a digital signal. An air core transformer is used to minimize the weight. The air core transformer is driven via two out of phase sawtooth signals which drive opposite ends of the transformer.

  3. 42 CFR 84.131 - Supplied-air respirators; required components.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Facepiece, hood, or helmet; (2) Air supply valve, orifice, or demand or pressure-demand regulator; (3) Hand operated or motor driven air blower; (4) Air supply hose; (5) Detachable couplings; (6) Flexible...

  4. 42 CFR 84.131 - Supplied-air respirators; required components.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Facepiece, hood, or helmet; (2) Air supply valve, orifice, or demand or pressure-demand regulator; (3) Hand operated or motor driven air blower; (4) Air supply hose; (5) Detachable couplings; (6) Flexible...

  5. 42 CFR 84.131 - Supplied-air respirators; required components.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Facepiece, hood, or helmet; (2) Air supply valve, orifice, or demand or pressure-demand regulator; (3) Hand operated or motor driven air blower; (4) Air supply hose; (5) Detachable couplings; (6) Flexible...

  6. 42 CFR 84.131 - Supplied-air respirators; required components.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Facepiece, hood, or helmet; (2) Air supply valve, orifice, or demand or pressure-demand regulator; (3) Hand operated or motor driven air blower; (4) Air supply hose; (5) Detachable couplings; (6) Flexible...

  7. 42 CFR 84.131 - Supplied-air respirators; required components.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Facepiece, hood, or helmet; (2) Air supply valve, orifice, or demand or pressure-demand regulator; (3) Hand operated or motor driven air blower; (4) Air supply hose; (5) Detachable couplings; (6) Flexible...

  8. Air supply system for an internal combustion engine

    SciTech Connect

    Eftink, A.J.

    1991-03-12

    This patent describes a reciprocating piston internal combustion engine having a crankshaft and at least two cylinders, each cylinder having a displacement volume V{sub 1}, the improved means for supplying air to each cylinder. It comprises: a rotary, trochoidal chamber air pump defining at least one pair of pumping chambers, the number of pumping chambers being equal to the number of cylinders in the engine; air intake conduits connecting each pumping chamber to one cylinder of the engine; a rotor rotatable in each pair of pumping chambers, the rotor having three faces such that passage of a face of the rotor through a pumping chamber forces air in the pumping chamber into the associated air intake conduit and, consequently, into the engine cylinder; and means interconnecting the rotor and the crankshaft so as to rotate the rotor approximately one revolution for every three revolutions of the crankshaft.

  9. 42 CFR 84.147 - Type B supplied-air respirator; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Type B supplied-air respirator; minimum... SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.147 Type B supplied-air respirator; minimum requirements. No Type...

  10. Stabilization of buoyancy-driven unstable vortex flow in mixed convection of air in a rectangular duct by tapering its top plate

    SciTech Connect

    Tseng, W.S.; Lin, W.L.; Yin, C.P.; Lin, C.L.; Lin, T.F.

    2000-02-01

    At high buoyancy-to-inertia ratio frequently encountered in various heat transfer equipment, the buoyancy-driven secondary vortex flow in a forced laminar flow through a bottom heated rectangular duct is rather unstable. Heat transfer augmentation associated with the buoyancy-driven vortex flow is desirable and welcome in many technological applications in which the efficient energy transport is of major concern. Here, stabilization of the buoyancy-driven unstable mixed convective vortex air flow in a bottom heated rectangular duct by tapering its top plate is investigated experimentally. Specifically, the duct is tapered so that its aspect ratio at the duct inlet is 4 and gradually raised to 12 at the exit of the duct. In the study the secondary flow in the duct is visualized and the steady and transient thermal characteristics of the flow are examined by measuring the spanwise distributions of the time-average temperature. The effects of the Reynolds and Grashof numbers on the vortex flow structure are studied in detail. Moreover, the spanwise-averaged Nusselt numbers for the horizontal rectangular and tapering ducts are also measured and compared. Furthermore, the time records of the air temperature are obtained to further detect the temporal stability of the flow. Over the ranges of the Re and Gr investigated for 5 {le} Re {le} 102 and 1.0 x 10{sup 4} {le} Gr {le} 1.7 x 10{sup 5}, the vortex flow induced in the rectangular duct exhibits temporal transition from a steady laminar to time periodic and then to chaotic state at increasing buoyancy-to-inertia ratio. Substantial change in the spatial structure of the vortex flow is also noted to accompany this temporal transition. The results for the tapering duct indicate that more vortex rolls can be induced due to the increase in the aspect ratio of the duct with the axial distance. But the vortex rolls are weaker and are completely stabilized by the tapering of the top plate.

  11. Evaluation of Air Mixing and Thermal Comfort From High Sidewall Supply Air Jets

    SciTech Connect

    Ridouane, E. H.

    2011-09-01

    Uniform mixing of conditioned air with room air is an essential factor for providing comfort in homes. The higher the supply flow rates the easier to reach good mixing in the space. In high performance homes, however, the flow rates required to meet the small remaining thermal loads are not large enough to maintain uniform mixing in the space. The objective of this study is to resolve this issue and maintain uniform temperatures within future homes. We used computational fluid dynamics modeling to evaluate the performance of high sidewall air supply for residential applications in heating and cooling modes. Parameters of the study are the supply velocity, supply temperature, diffuser dimensions, and room dimensions. Laboratory experiments supported the study of thermal mixing in heating mode; we used the results to develop a correlation to predict high sidewall diffuser performance. For cooling mode, numerical analysis is presented. The results provide information to guide the selection of high sidewall supply diffusers to maintain proper room mixing for heating and cooling of high performance homes. It is proven that these systems can achieve good mixing and provide acceptable comfort levels. Recommendations are given on the operating conditions to guarantee occupant comfort.

  12. Ignition of lean fuel-air mixtures in a premixing-prevaporizing duct at temperatures up to 1000 K

    NASA Technical Reports Server (NTRS)

    Tacina, R. R.

    1980-01-01

    Conditions were determined in a premixing prevaporizing fuel preparation duct at which ignition occurred. An air blast type fuel injector with nineteen fuel injection points was used to provide a uniform spatial fuel air mixture. The range of inlet conditions where ignition occurred were: inlet air temperatures of 600 to 1000 K air pressures of 180 to 660 kPa, equivalence ratios (fuel air ratio divided by stoichiometric fuel air ratio) from 0.12 to 1.05, and velocities from 3.5 to 30 m/s. The duct was insulated and the diameter was 12 cm. Mixing lengths were varied from 16.5 to 47.6 and residence times ranged from 4.6 to 107 ms. The fuel was no. 2 diesel. Results show a strong effect of equivalence ratio, pressure and temperature on the conditions where ignition occurred. The data did not fit the most commonly used model of auto-ignition. A correlation of the conditions where ignition would occur which apply to this test apparatus over the conditions tested is (p/V) phi to the 1.3 power = 0.62 e to the 2804/T power where p is the pressure in kPa, V is the velocity in m/e, phi is the equivalence ratio, and T is the temperature in K. The data scatter was considerable, varying by a maximum value of 5 at a given temperature and equivalence ratio. There was wide spread in the autoignition data contained in the references.

  13. Laboratory evaluation of welder's exposure and efficiency of air duct ventilation for welding work in a confined space.

    PubMed

    Ojima, J; Shibata, N; Iwasaki, T

    2000-01-01

    CO2 arc welding in a confined space was simulated in a laboratory by manipulating a welding robot which worked in a small chamber to experimentally evaluate the welder's exposure to welding fumes, ozone and carbon monoxide (CO). The effects of the welding arc on the air temperature rise and oxygen (O2) concentration in the chamber were also investigated. The measuring points for these items were located in the presumed breathing zone of a welder in a confined space. The time averaged concentrations of welding fumes, ozone and CO during the arcing time were 83.55 mg/m3, 0.203 ppm and 0.006%, respectively, at a welding current of 120A-200A. These results suggest serious exposure of a welder who operates in a confined space. Air temperature in the chamber rose remarkably due to the arc heat and the increase in the welding current. No clear decrease in the O2 concentration in the chamber was recognized during this welding operation. A model of air duct ventilation was constructed in the small chamber to investigate the strategy of effective ventilation for hazardous welding contaminants in a confined space. With this model we examined ventilation efficiency with a flow rate of 1.08-1.80 m3/min (ventilation rate for 0.40-0.67 air exchanges per minute) in the chamber, and proved that the exposure level was not drastically reduced during arcing time by this air duct ventilation, but the residual contaminants were rapidly exhausted after the welding operation. PMID:10680307

  14. Flame behaviors of propane/air premixed flame propagation in a closed rectangular duct with a 90-deg bend

    NASA Astrophysics Data System (ADS)

    He, Xuechao; Sun, Jinhua; Yuen, K. K.; Ding, Yibin; Chen, Sining

    2008-11-01

    Experiments of flame propagation in a small, closed rectangular duct with a 90° bend were performed for a propane-air mixture. The high speed camera and Schlieren techniques were used to record images of flame propagation process in the combustion pipe. Meanwhile, the fine thermocouples and ion current probes were applied to measure the temperature distribution and reaction intensity of combustion. The characteristics of propane-air flame and its microstructure were analyzed in detail by the experimental results. In the test, the special tulip flame formation was observed. Around the bend, the flame tip proceeded more quickly at the lower side with the flame front elongated toward the axial direction. And transition to turbulent flame occurred. It was suggested that fluctuations of velocity, ion current and temperature were mainly due to the comprehensive effects of multi-wave and the intense of turbulent combustion.

  15. Energy and air emission effects of water supply.

    PubMed

    Stokes, Jennifer R; Horvath, Arpad

    2009-04-15

    Life-cycle air emission effects of supplying water are explored using a hybrid life-cycle assessment For the typically sized U.S. utility analyzed, recycled water is preferable to desalination and comparable to importation. Seawater desalination has an energy and air emission footprint that is 1.5-2.4 times larger than that of imported water. However, some desalination modes fare better; brackish groundwater is 53-66% as environmentally intensive as seawater desalination. The annual water needs (326 m3) of a typical Californian that is met with imported water requires 5.8 GJ of energy and creates 360 kg of CO2 equivalent emissions. With seawater desalination, energy use would increase to 14 GJ and 800 kg of CO2 equivalent emissions. Meeting the water demand of California with desalination would consume 52% of the state's electricity. Supply options were reassessed using alternative electricity mixes, including the average mix of the United States and several renewable sources. Desalination using solar thermal energy has lower greenhouse gas emissions than that of imported and recycled water (using California's electricity mix), but using the U.S. mix increases the environmental footprint by 1.5 times. A comparison with a more energy-intensive international scenario shows that CO2 equivalent emissions for desalination in Dubai are 1.6 times larger than in California. The methods, decision support tool (WEST), and results of this study should persuade decision makers to make informed water policy choices by including energy consumption and material use effects in the decision-making process. PMID:19475934

  16. Evaluation of Air Mixing and Thermal Comfort From High Sidewall Supply Air Jets

    SciTech Connect

    Ridouane, El Hassan

    2011-09-01

    Uniform mixing of conditioned air with room air is an essential factor for providing comfort in homes. The objective of the study outlined in this report is to resolve the issue that the flow rates that are required to meet the small remaining thermal loads are not large enough to maintain uniform mixing in the space.and maintain uniform temperatures within future homes. The results provide information to guide the selection of high sidewall supply diffusers to maintain proper room mixing for heating and cooling of high performance homes.

  17. 42 CFR 84.149 - Type C supplied-air respirator, demand and pressure demand class; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.149 Type C supplied-air respirator... air-supply system, and the range of hose length for the respirator. For example, he might specify that... pressure at the point of attachment of the hose to the air-supply system shall not exceed 863 kN/m.2...

  18. 42 CFR 84.149 - Type C supplied-air respirator, demand and pressure demand class; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.149 Type C supplied-air respirator... air-supply system, and the range of hose length for the respirator. For example, he might specify that... pressure at the point of attachment of the hose to the air-supply system shall not exceed 863 kN/m.2...

  19. 42 CFR 84.149 - Type C supplied-air respirator, demand and pressure demand class; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.149 Type C supplied-air respirator... air-supply system, and the range of hose length for the respirator. For example, he might specify that... pressure at the point of attachment of the hose to the air-supply system shall not exceed 863 kN/m.2...

  20. 42 CFR 84.149 - Type C supplied-air respirator, demand and pressure demand class; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.149 Type C supplied-air respirator... air-supply system, and the range of hose length for the respirator. For example, he might specify that... pressure at the point of attachment of the hose to the air-supply system shall not exceed 863 kN/m.2...

  1. Loft duct project report

    SciTech Connect

    Reed, J.R.

    1993-06-01

    On October 16, 1992, during a routine examination of the loft of Building 332, the Building Coordinator observed cracks in the welds of the duct work that services the fume hoods for Rooms 1313, 1321, and 1329. Further examination revealed cracks in the weld of the duct work that services the gloveboxes in Rooms 1321 and 1329. Upon discovery of the cracked welds, facility management immediately took the following two actions: Because one crack in the fume hood exhaust extended 70% around the duct circumference, a 1-ton chain fall was used to secure the duct to the roof support structure to prevent the duct from falling if the duct completely fractured. The Facility Manager suspended plutonium handling operations in the gloveboxes and work in the fume hoods in the affected rooms until the situation could be thoroughly investigated. Building 332 is ventilated by drawing conditioned air from the building hallways into the laboratories, hoods, and gloveboxes. This air is filtered through two sets of high-efficiency particulate air (HEPA) filters before being exhausted from the facility. Figure 1 is a schematic of the typical air flow pattern for the facility. All affected duct work is located in the loft of the facility or pressure zone 4. This ducting is fabricated from 12-, 14- and 16-gauge, 304 stainless-steel sheet stock and joined by the Gas Tungsten Arc Welding (GTAW) process.

  2. Vortex generator induced heat transfer augmentation past a rib in a heated duct air flow

    SciTech Connect

    Myrum, T.A.; Acharya, S.; Inamdar, S.; Mehrotra, A. )

    1992-02-01

    The present investigation represents the initial phase of a comprehensive experimental program designed to study the potential for increasing the heat transfer per unit pressure drop in a ribbed duct by positioning vortex generators at key locations in the flow. In particular, the present investigation consists of a rib positioned at the inlet to a rectangular test section with uniform heating at its bottom wall. Local and average Nusselt number results are obtained for a circular rod positioned either immediately above or just downstream of the rib.

  3. Reduced heat stress in offices in the tropics using solar powered drying of the supply air.

    PubMed

    Gunnarsen, L; Santos, A M B

    2002-12-01

    Many solutions to indoor climate problems known from developed countries may have prohibitive installation and running costs in developing countries. The purpose was to develop a low-cost solution to heat stress in a hot and humid environment based on solar powered drying of supply air. Dry supply air may facilitate personal cooling by increased evaporation of sweat. Heat acclimatized people with efficient sweating may in particular benefit from this cooling. A prototype solar powered supply system for dried-only air was made. Air from the system was mixed with room air, heated to six different combinations of temperature and humidity and led to Personal Units for Ventilation and Cooling (PUVAC) in six cubicles simulating office workplaces. A total of 123 heat acclimatized subjects were exposed 45 min in each of the cubicles. A model for the combined effect of operative temperature of room, moisture content of room air, temperature of supply air and moisture content of supply air was developed based on the experiments. Reduction of moisture content in the supply air by 1.6 g/kg had the same effect as lowering the operative temperature by 1 degree C. The solar-powered system for supplying dry air is a low-cost alternative to traditional air conditioning in hot and humid regions. PMID:12532757

  4. Air/fuel supply system for use in a gas turbine engine

    DOEpatents

    Fox, Timothy A; Schilp, Reinhard; Gambacorta, Domenico

    2014-06-17

    A fuel injector for use in a gas turbine engine combustor assembly. The fuel injector includes a main body and a fuel supply structure. The main body has an inlet end and an outlet end and defines a longitudinal axis extending between the outlet and inlet ends. The main body comprises a plurality of air/fuel passages extending therethrough, each air/fuel passage including an inlet that receives air from a source of air and an outlet. The fuel supply structure communicates with and supplies fuel to the air/fuel passages for providing an air/fuel mixture within each air/fuel passage. The air/fuel mixtures exit the main body through respective air/fuel passage outlets.

  5. Flashback from waste gas incinerator into air supply piping

    SciTech Connect

    Anderson, S.E.; Dowell, A.M. III; Mynaugh, J.B. )

    1992-04-01

    A waste gas incinerator experienced a flashback with a pressure wave in the Suction Vent Gas (SVG) system. Extensive damage resulted to the SVG flame arrestor, SVG fan, SVG valves, and incinerator piping. There were no injuries. The primary cause of the incident is believed to have been a fuel rich SVG stream that was rapidly introduced into the incinerator creating a puff.' This puff' allowed flame from the natural gas ring burner to blow back into the windbox igniting the fuel rich SVG. The combustion of gas in the ducting then created a pressure wave that blew apart the flame arrestor and caused the remainder of the damage.

  6. Ducted fan type gas turbine engine power plants

    SciTech Connect

    Balzer, R.L.

    1992-02-25

    This patent describes a ducted fan type power plant which is cable of generating reverse thrust. It comprises: a gas turbine engine; a fan driven by the engine; an elongated bypass duct which is open at its front and rear ends and surrounds the fan, the bypass duct having a fixed forward section and a rear section which can be translated away from the fixed section as the pitch of the fan blades is reversed to reverse the flow of air through the bypass duct and generate a thrust directed from the front toward the rear of the power plant, thereby allowing air to be induced into the bypass duct through the downstream end thereof and also through the annular gap between the fixed and translated, rear sections of the bypass duct; means for generating a supply of high velocity fluid; means for injecting the high velocity fluid into the bypass duct from a locus to the rear means for delivering the high velocity fluid from the generating means to the injecting means.

  7. Study of Air Ingress Across the Duct During the Accident Conditions

    SciTech Connect

    Hassan, Yassin

    2013-05-06

    The goal of this project is to study the fundamental physical phenomena associated with air ingress in very high temperature reactors (VHTRs). Air ingress may occur due to a rupture of primary piping and a subsequent breach in the primary pressure boundary in helium-cooled and graphite-moderated VHTRs. Significant air ingress is a concern because it introduces potential to expose the fuel, graphite support rods, and core to a risk of severe graphite oxidation. Two of the most probable air ingress scenarios involve rupture of a control rod or fuel access standpipe, and rupture in the main coolant pipe on the lower part of the reactor pressure vessel. Therefore, establishing a fundamental understanding of air ingress phenomena is critical in order to rationally evaluate safety of existing VHTRs and develop new designs that minimize these risks. But despite this importance, progress toward development these predictive capabilities has been slowed by the complex nature of the underlying phenomena. The combination of inter-diffusion among multiple species, molecular diffusion, natural convection, and complex geometries, as well as the multiple chemical reactions involved, impose significant roadblocks to both modeling and experiment design. The project team will employ a coordinated experimental and computational effort that will help gain a deeper understanding of multiphased air ingress phenomena. This project will enhance advanced modeling and simulation methods, enabling calculation of nuclear power plant transients and accident scenarios with a high degree of confidence. The following are the project tasks: Perform particle image velocimetry measurement of multiphase air ingresses; and, Perform computational fluid dynamics analysis of air ingress phenomena.

  8. FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS

    EPA Science Inventory

    The filtration efficiency of ventilation air cleaners is highly particle-size dependent over the 0.01 to 3 μm diameter size range. Current standardized test methods, which determine only overall efficiencies for ambient aerosol or other test aerosols, provide data of limited util...

  9. Advanced Duct Sealing Testing

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.

    2003-08-01

    Duct leakage has been identified as a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums or branches in the duct system. At each of these connections a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have typically shown that these seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory has been testing sealant durability for several years. Typical duct tape (i.e. fabric backed tapes with natural rubber adhesives) was found to fail more rapidly than all other duct sealants. This report summarizes the results of duct sealant durability testing of five UL 181B-FX listed duct tapes (three cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The first test involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars, and sheet metal ''collar-to-plenum joints'' pressurized with 200 F (93 C) air. The second test consisted of baking duct tape specimens in a constant 212 F (100 C) oven following the UL 181B-FX ''Temperature Test'' requirements. Additional tests were also performed on only two tapes using sheet metal collar-to-plenum joints. Since an unsealed flexible duct joint can have a variable leakage depending on the positioning of the flexible duct core, the durability of the flexible duct joints could not be based on the 10% of unsealed leakage criteria. Nevertheless, the leakage of the sealed specimens prior to testing could be considered as a basis for a failure criteria. Visual inspection was also documented throughout the tests. The flexible duct core-to-collar joints were inspected monthly, while the sheet metal collar-to-plenum joints were inspected

  10. 42 CFR 84.155 - Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE supplied-air respirator; minimum requirements. 84.155 Section... Respirators § 84.155 Airflow resistance test; Type C supplied-air respirator, continuous flow class and...

  11. Air supply using an ionic wind generator in a proton exchange membrane fuel cell

    NASA Astrophysics Data System (ADS)

    Kwon, Kilsung; Li, Longnan; Park, Byung Ho; Lee, Seung Jun; Kim, Daejoong

    2015-06-01

    A new air supply is demonstrated for a portable polymer electrolyte membrane fuel cell (PEMFC). The air supply is an ionic wind generator (IWG) with a needle-to-cylinder configuration. The IWG supplies air to the portable PEMFC owing to momentum transfer to the air by charged molecules generated by the corona discharge from a high applied potential. There is no difference in the performance of the PEMFC when compressed air and the IWG are used as the air supply. For the varying interelectrode distance, IWG performance is varied and measured in terms of the flow rate and current. At the interelectrode distance of 9.0 mm, the air flow rate is a suitable for the portable PEMFC with low power consumption. When the IWG is used to supply air to the portable PEMFC, it is found that the flow rate per unit power consumed decreases with the applied voltage, the gross power generation monotonously increases with the applied voltage, and the highest net power (268 mW) is obtained at the applied voltage of 8.5 kV. The parasitic power ratio reaches a minimum value of ∼0.06 with the applied IWG voltage of 5.5 kV.

  12. Lensing duct

    DOEpatents

    Beach, R.J.; Benett, W.J.

    1994-04-26

    A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding is described. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic. 3 figures.

  13. Lensing duct

    DOEpatents

    Beach, Raymond J. , Benett

    1994-01-01

    A lensing duct to condense (intensify) light using a combination of front surface lensing and reflective waveguiding. The duct tapers down from a wide input side to a narrow output side, with the input side being lens-shaped and coated with an antireflective coating for more efficient transmission into the duct. The four side surfaces are uncoated, preventing light from escaping by total internal reflection as it travels along the duct (reflective waveguiding). The duct has various applications for intensifying light, such as in the coupling of diode array pump light to solid state lasing materials, and can be fabricated from inexpensive glass and plastic.

  14. Duct leakage impacts on VAV system performance in California large commercial buildings

    SciTech Connect

    Wray, Craig P.; Matson, Nance E.

    2003-10-01

    The purpose of this study is to evaluate the variability of duct leakage impacts on air distribution system performance for typical large commercial buildings in California. Specifically, a hybrid DOE-2/TRNSYS sequential simulation approach was used to model the energy use of a low-pressure terminal-reheat variable-air-volume (VAV) HVAC system with six duct leakage configurations (tight to leaky) in nine prototypical large office buildings (representing three construction eras in three California climates where these types of buildings are common). Combined fan power for the variable-speed-controlled supply and return fans at design conditions was assumed to be 0.8 W/cfm. Based on our analyses of the 54 simulation cases, the increase in annual fan energy is estimated to be 40 to 50% for a system with a total leakage of 19% at design conditions compared to a tight system with 5% leakage. Annual cooling plant energy also increases by about 7 to 10%, but reheat energy decreases (about 3 to 10%). In combination, the increase in total annual HVAC site energy is 2 to 14%. The total HVAC site energy use includes supply and return fan electricity consumption, chiller and cooling tower electricity consumption, boiler electricity consumption, and boiler natural gas consumption. Using year 2000 average commercial sector energy prices for California ($0.0986/kWh and $7.71/Million Btu), the energy increases result in 9 to 18% ($7,400 to $9,500) increases in HVAC system annual operating costs. Normalized by duct surface area, the increases in annual operating costs are 0.14 to 0.18 $/ft{sup 2}. Using a suggested one-time duct sealing cost of $0.20 per square foot of duct surface area, these results indicate that sealing leaky ducts in VAV systems has a simple payback period of about 1.3 years. Even with total leakage rates as low as 10%, duct sealing is still cost effective. This suggests that duct sealing should be considered at least for VAV systems with 10% or more total duct

  15. 46 CFR 197.432 - Surface-supplied air diving.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... at depths less than 190 fsw, except that dives with bottom times of 30 minutes or less may be conducted to depths of 220 fsw; (b) Each diving operation has a primary breathing gas supply; (c) Each diver... deeper than 130 fsw or outside the no-decompression limits— (1) Each diving operation has a...

  16. Longevity of duct tape in residential air distribution systems: 1-D, 2-D, and 3-D joints

    SciTech Connect

    Abushakra, Bass

    2002-05-30

    The aging tests conducted so far showed that duct tape tends to degrade in its performance as the joint it is applied to requires a geometrical description of a higher number of space dimensions (1-D, 2-D, 3-D). One-dimensional joints are the easiest to seal with duct tape, and thus the least to experience failure. Two-dimensional joints, such as the flexible duct core-to-collar joints tested in this study, are less likely to fail than three-dimensional collar-to-plenum joints, as the shrinkage could have a positive effect in tightening the joint. Three-dimensional joints are the toughest to seal and the most likely to experience failure. The 2-D flexible duct core-to-collar joints passed the six-month period of the aging test in terms of leakage, but with the exception of the foil-butyl tape, showed degradation in terms hardening, brittleness, partial peeling, shrinkage, wrinkling, delamination of the tape layers, flaking, cracking, bubbling, oozing and discoloration. The baking test results showed that the failure in the duct tape joints could be attributed to the type of combination of the duct tape and the material it is applied to, as the duct tape behaves differently with different substrates. Overall, the foil-butyl tape (Tape 4) had the best results, while the film tape (Tape 3) showed the most deterioration. The conventional duct tapes tested (Tape 1 and Tape 2) were between these two extremes, with Tape 2 performing better than Tape 1. Lastly, we found that plastic straps became discolored and brittle during the tests, and a couple of straps broke completely. Therefore, we recommend that clamping the duct-taped flexible core-to-collar joints should be done with metallic adjustable straps.

  17. 42 CFR 84.130 - Supplied-air respirators; description.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of air when the blower is not operating, a strong large-diameter hose having a low resistance to... material, and with shielding material such as plastic, glass, woven wire, sheet metal, or other suitable... immediately dangerous to life or health, which consists of a strong large-diameter hose with low resistance...

  18. Energy supplies and future engines for land, sea, and air.

    PubMed

    Wilson, David Gordon

    2012-06-01

    The years 2012 and beyond seem likely to record major changes in energy use and power generation. The Japanese tsunami has resulted in large countries either scaling back or abolishing the future use of nuclear energy. The discovery of what seems like vast amounts of economically deliverable natural gas has many forecasting a rapid switch from coal- to gas-fired generating plants. On the other hand, environmentalists have strong objections to the production of natural gas and of petroleum by hydraulic fracturing from shale, or by extraction of heavy oil. They believe that global warming from the use of fossil fuels is now established beyond question. There has been rapid progress in the development of alternative energy supplies, particularly from on-shore and off-shore wind. Progress toward a viable future energy mix has been slowed by a U.S. energy policy that seems to many to be driven by politics. The author will review the history of power and energy to put all of the above in context and will look at possible future developments. He will propose what he believes to be an idealized energy policy that could result in an optimum system that would be arrived at democratically. PMID:22788100

  19. Downhole steam generator using low pressure fuel and air supply

    DOEpatents

    Fox, Ronald L.

    1983-01-01

    An apparatus for generation of steam in a borehole for penetration into an earth formation wherein a spiral, tubular heat exchanger is used in the combustion chamber to isolate the combustion process from the water being superheated for conversion into steam. The isolation allows combustion of a relatively low pressure oxidant and fuel mixture for generating high enthalpy steam. The fuel is preheated by feedback of combustion gases from the top of the combustion chamber through a fuel preheater chamber. The hot exhaust gases of combustion at the bottom of the combustion chamber, after flowing over the heat exchanger enter an exhaust passage and pipe. The exhaust pipe is mounted inside the water supply line heating the water flowing into the heat exchanger. After being superheated in the heat exchanger, the water is ejected through an expansion nozzle and converts into steam prior to penetration into the earth formation. Pressure responsive doors are provided at a steam outlet downstream of the nozzle and close when the steam pressure is lost due to flameout.

  20. Downhole steam generator using low pressure fuel and air supply

    SciTech Connect

    Fox, R.L.

    1983-06-28

    An apparatus is claimed for generation of steam in a borehole for penetration into an earth formation wherein a spiral, tubular heat exchanger is used in the combustion chamber to isolate the combustion process from the water being superheated for conversion into steam. The isolation allows combustion of a relatively low pressure oxidant and fuel mixture for generating high enthalpy steam. The fuel is preheated by feedback of combustion gases from the top of the combustion chamber through a fuel preheater chamber. The hot exhaust gases of combustion at the bottom of the combustion chamber, after flowing over the heat exchanger enter an exhaust passage and pipe. The exhaust pipe is mounted inside the water supply line heating the water flowing into the heat exchanger. After being superheated in the heat exchanger, the water is ejected through an expansion nozzle and converts into steam prior to penetration into the earth formation. Pressure responsive doors are provided at a steam outlet downstream of the nozzle and close when the steam pressure is lost due to flameout.

  1. 42 CFR 84.155 - Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... respirator, continuous flow class and Type CE supplied-air respirator; minimum requirements. 84.155 Section... Respirators § 84.155 Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type... shall not exceed 25 mm. (1 inch) of water-column height when the air flow into the...

  2. Autoignition in a premixing-prevaporizing fuel duct using 3 different fuel injection systems at inlet air temperatures to 1250 K

    NASA Technical Reports Server (NTRS)

    Tacina, R. R.

    1983-01-01

    Conditions were determined in a continuous-flow, premixing-prevaporizing duct at which autoignition occurred. Test conditions were representative of an advanced, regenerative-cycle, automotive gas turbine. The test conditions inlet air temperatures from 600 to 1250 K (a vitiated preheater was used), pressures from 170 to 600 kPa, air velocities of 10 to 30 m/sec, equivalence ratios from 0.3 to 1.0, mixing lengths from 10 to 60 cm, and residence times of 2 to 100 ms. The fuel was diesel number 2. The duct was insulated and had an inside diameter of 12 cm. Three different fuel injection systems were used: One was a single simplex pressure atomizer, and the other two were multiple-source injectors. The data obtained with the simplex and one of the multiple-source injectors agreed satisfactorily with the references and correlated with an Arrenhius expression. The data obtained with the other multiple source injector, which used multiple cones to improve the fuel-air distribution, did not correlate well with residence time.

  3. Wearable air supply for pneumatic artificial hearts and ventricular assist devices.

    PubMed

    Sipin, A J; Fabrey, W J; Smith, S H; Doussourd, J D; Olsen, D B

    1992-08-01

    An experimental wearable air supply for pneumatic artificial hearts and ventricular assist devices has been built and tested. The unit eliminates the need for tethering to a large, stationery driver. The miniaturized air supply is designed for ambulatory patients with implanted pulsatile pneumatic total artificial hearts (TAH) or pneumatic left-ventricular assist devices (LVAD), to permit mobility in clinical and home settings. The device has major short-term utility as a supply for pneumatic TAH or VAD bridges in patients awaiting heart transplants. The system design for the wearable driver includes a novel, fast rotary compressor, driven by a brushless direct current (DC) motor to supply air to the ventricle through an electromagnetically actuated directional valve, all controlled by a microcomputer. Stroke volume from 0 to 200 cc; pulse rate from 60 to 160 bpm, and duty cycle from 33% to 50% are selected on a keyboard, and the selected or measured parameters can be shown on a liquid crystal display. For control of delivery from a single ventricular assist device, stroke volume is controlled by variation of compressor speed. In the wearable air supply for a TAH, a single compressor drives both ventricles alternately through a double-acting directional valve. Air volume delivered to the left ventricle is adjusted by variation of compressor speed, and air volume to the right ventricle by variation of ejection time. The effect on blood flow rate of the lower impedance to the right ventricle is compensated by provision of a two-stage compressor, in which a single stage drives the right ventricle, and both stages connected in parallel drive the left ventricle. The overall dimensions of the prototype air supply for driving either a TAH or LVAD are 4.5 by 7.8 by 4.5 inches, including an emergency battery with a duration of 15 to 30 min depending on load. The weight is presently 5.5 lb, but this will be reduced in a production design and for a dedicated LVAD air supply

  4. Dynamic investigation of PEFC stacks in interaction with the air supply system

    NASA Astrophysics Data System (ADS)

    Philipps, F.; Simons, G.; Schiefer, K.

    This paper explores the behaviour of a dynamically operated fuel cell system regarding to an automotive application, examining the air supply and their interaction with the fuel cell stacks. The dynamic limits of stack operation are also discussed. Finally, the paper provides a description of the test facility used in these investigations. The research of dynamically operated fuel cell stacks shows that in order to achieve high energy efficiency, a power-dependent modulation of the pressure and flow rate of the air supply is necessary. A test facility designed for energy management and power train research (up to 42 kW) was used for the experiment. A number of 11.5 kW fuel cell stacks was examined experimentally with respect to performance in interaction with the air supply in stationary and dynamic operation. The stacks were tested individually and in parallel. All of them were operated "dead-end" on the hydrogen side. Experimental results varying the parameters and load curves applied to the air supply system are given in the paper. The results show different dynamic behaviours between the stacks and a substantial difference in efficiency and dynamic response of the fuel cell system operated with different strategies. The results of different operating strategies for fuel cell systems, with respect to the interaction between the fuel cell stack and the air supply and in their dependency on air mass flow and pressure level are presented. The examinations were done with the test facility using real current demand profile of the experimental car HyLite ® from zero to full load and the New European Drive Cycle (NEDC).

  5. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2010-12-14

    A method for forming a duct access region through one side of a previously installed air duct, wherein the air duct has an air flow with an air flow direction by inserting an aerosol injector into a previously installed air duct through the access region. The aerosol injector includes a liquid tube having a liquid tube orifice for ejecting a liquid to be atomized; and a propellant cap. The method is accomplished by aligning the aerosol injector with the direction of air flow in the duct; activating an air flow within the duct; and spraying a sealant through the aerosol injector to seal the duct in the direction of the air flow.

  6. Duct closure

    DOEpatents

    Vowell, Kennison L.

    1987-01-01

    A closure for an inclined duct having an open upper end and defining downwardly extending passageway. The closure includes a cap for sealing engagement with the open upper end of the duct. Associated with the cap are an array of vertically aligned plug members, each of which has a cross-sectional area substantially conforming to the cross-sectional area of the passageway at least adjacent the upper end of the passageway. The plug members are interconnected in a manner to provide for free movement only in the plane in which the duct is inclined. The uppermost plug member is attached to the cap means and the cap means is in turn connected to a hoist means which is located directly over the open end of the duct.

  7. 42 CFR 84.148 - Type C supplied-air respirator, continuous flow class; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Type C supplied-air respirator, continuous flow class; minimum requirements. 84.148 Section 84.148 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES...

  8. Cornice Duct System

    SciTech Connect

    Wayne Place; Chuck Ladd

    2004-10-29

    SYNERGETICS, INC., has designed, developed, and tested an air handling duct system that integrates the air duct with the cornice trim of interior spaces. The device has the advantage that the normal thermal losses from ducts into unconditioned attics and crawl spaces can be totally eliminated by bringing the ducts internal to the conditioned space. The following report details work conducted in the second budget period to develop the Cornice Duct System into a viable product for use in a variety of residential or small commercial building settings. A full-scale prototype has been fabricated and tested in a laboratory test building at the Daylighting Facility at North Carolina State University., Based on the results of that testing, the prototype design as been refined, fabricated, installed, and extensively tested in a residential laboratory house. The testing indicates that the device gives substantially superior performance to a standard air distribution system in terms of energy performance and thermal comfort. Patent Number US 6,511,373 B2 has been granted on the version of the device installed and tested in the laboratory house. (A copy of that patent is attached.) Refinements to the device have been carried through two additional design iterations, with a particular focus on reducing installation time and cost and refining the air control system. These new designs have been fabricated and tested and show substantial promise. Based on these design and testing iterations, a final design is proposed as part of this document. That final design is the basis for a continuation in part currently being filed with the U.5, Patent office.

  9. Effectiveness of duct sealing and duct insulation in multi-family buildings. Final report

    SciTech Connect

    Karins, N.H.; Tuluca, A.; Modera, M.

    1997-07-01

    This research investigated the cost-effectiveness of sealing and insulating the accessible portions of duct systems exposed to unconditioned areas in multifamily housing. Airflow and temperature measurements were performed in 25 apartments served by 10 systems a 9 multi-family properties. The measurements were performed before and after each retrofit, and included apartment airflow (supply and return), duct system temperatures, system fan flow and duct leakage area. The costs for each retrofit were recorded. The data were analyzed and used to develop a prototypical multifamily house. This prototype was used in energy simulations (DOE-2.1E) and air infiltration simulations (COMIS 2.1). The simulations were performed for two climates: New York City and Albany. In each climate, one simulation was performed assuming the basement was tight, and another assuming the basement was leaky. Simulation results and average retrofit costs were used to calculate cost-effectiveness. The results of the analysis indicate that sealing leaks of the accessible ductwork is cost-effective under all conditions simulated (simple payback was between 3 and 4 years). Insulating the accessible ductwork, however, is only cost-effective for buildings with leaky basement, in both climates (simple paybacks were less than 5 years). The simple payback period for insulating the ducts in buildings with tight basements was greater than 10 years, the threshold of cost-effectiveness for this research. 13 refs., 5 figs., 27 tabs.

  10. TWO NEW DUCT LEAKAGE TESTS

    SciTech Connect

    ANDREWS,J.W.

    1998-12-01

    Two variations on the tests for duct leakage currently embodied in ASHRAE Standard 152P (Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems) are presented. Procedures are derived for calculating supply and return duct leakage to/from outside using these new variations. Results of these tests are compared with the original ones in Standard 152P on the basis of data collected in three New York State homes.

  11. Two New Duct Leakage Tests

    SciTech Connect

    Andrews, J.W.

    1998-12-01

    Two variations on the tests for duct leakage currently embodied in ASHRAE Standard 152P (Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems) are presented. Procedures are derived for calculating supply and return duct leakage to/from outside using these new variations. Results of these tests are compared with the original ones in Standard 152P on the basis of data collected in three New York State homes.

  12. Local ventilation for powder handling--combination of local supply and exhaust air.

    PubMed

    Heinonen, K; Kulmala, I; Säämänen, A

    1996-04-01

    The performance of a modified local ventilation unit equipped with local supply and exhaust ventilation was evaluated during the manual handling of flour additive powder. The investigation tested five different configurations to study the effects of the exhaust opening location and local supply air on worker exposure. The measurements were done under controlled conditions in a test room. The breathing zone (BZ) dust concentration was measured by gravimetric sampling and real time monitoring. The different local ventilation configurations were also modeled numerically using computational fluid dynamics. Without local ventilation the average BZ dust concentration was 42 mg/m3. With local exhaust only the exposure was reduced below 1 mg/m3. The addition of local supply air further reduced the exposure to below 0.5 mg/m3. The lowest results were achieved by locating two exhaust openings on either side of the contaminant source combined with local supply air. With this configuration the average BZ exposure was only 0.08 mg/m3, a reduction of 99.8%. Numerical simulations also gave useful information about the airflow fields in stationary conditions. However, the worker's exposure was greatly affected by body movements, and this was not possible to simulate numerically. The results of this investigation can be useful when controlling dust exposure in manual powder handling operations. PMID:8901237

  13. 42 CFR 84.143 - Terminal fittings or chambers; Type B supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Terminal fittings or chambers; Type B supplied-air... HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.143 Terminal fittings or chambers; Type...

  14. 42 CFR 84.156 - Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE... C supplied-air respirator, demand class; minimum requirements. (a) Inhalation resistance shall...

  15. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The...

  16. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The...

  17. 42 CFR 84.156 - Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE... C supplied-air respirator, demand class; minimum requirements. (a) Inhalation resistance shall...

  18. 42 CFR 84.156 - Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE... C supplied-air respirator, demand class; minimum requirements. (a) Inhalation resistance shall...

  19. 42 CFR 84.156 - Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE... C supplied-air respirator, demand class; minimum requirements. (a) Inhalation resistance shall...

  20. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The...

  1. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The...

  2. 42 CFR 84.154 - Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance test; Type B and Type BE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.154 Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements. (a) Airflow resistance shall...

  3. 42 CFR 84.154 - Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance test; Type B and Type BE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.154 Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements. (a) Airflow resistance shall...

  4. 42 CFR 84.153 - Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance test, Type A and Type AE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.153 Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements. (a) Airflow resistance will...

  5. 42 CFR 84.154 - Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance test; Type B and Type BE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.154 Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements. (a) Airflow resistance shall...

  6. 42 CFR 84.153 - Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance test, Type A and Type AE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.153 Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements. (a) Airflow resistance will...

  7. 42 CFR 84.153 - Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance test, Type A and Type AE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.153 Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements. (a) Airflow resistance will...

  8. 42 CFR 84.154 - Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance test; Type B and Type BE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.154 Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements. (a) Airflow resistance shall...

  9. 42 CFR 84.153 - Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance test, Type A and Type AE... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.153 Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements. (a) Airflow resistance will...

  10. Distribution and Room Air Mixing Risks to Retrofitted Homes

    SciTech Connect

    Burdick, A.

    2014-12-01

    ​Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  11. Distribution and Room Air Mixing Risks to Retrofitted Homes

    SciTech Connect

    Burdick, A.

    2014-12-01

    Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  12. Ramjet bypass duct and preburner configuration

    NASA Technical Reports Server (NTRS)

    Orlando, Robert J. (Inventor)

    1994-01-01

    A combined turbofan and ramjet aircraft engine includes a forward bypass duct which allows the engine to operate more efficiently during the turbofan mode of operation. By mounting a ramjet preburner in the forward duct and isolating this duct from the turbofan bypass air, a transition from turbofan operation to ramjet operation can take place at lower flight Mach numbers without incurring pressure losses or blockage in the turbofan bypass air.

  13. Experimental investigation of personal air supply nozzle use in aircraft cabins.

    PubMed

    Fang, Zhaosong; Liu, Hong; Li, Baizhan; Baldwin, Andrew; Wang, Jian; Xia, Kechao

    2015-03-01

    To study air passengers' use of individual air supply nozzles in aircraft cabins, we constructed an experimental chamber which replicated the interior of a modern passenger aircraft. A series of experiments were conducted at different levels of cabin occupancy. Survey data were collected focused on the reasons for opening the nozzle, adjusting the level of air flow, and changing the direction of the air flow. The results showed that human thermal and draft sensations change over time in an aircraft cabin. The thermal sensation response was highest when the volunteers first entered the cabin and decreased over time until it stablized. Fifty-one percent of volunteers opened the nozzle to alleviate a feeling of stuffiness, and more than 50% adjusted the nozzle to improve upper body comfort. Over the period of the experiment the majority of volunteers chose to adjust their the air flow of their personal system. This confirms airline companies' decisions to install the individual aircraft ventilation systems in their aircraft indicates that personal air systems based on nozzle adjustment are essential for cabin comfort. These results will assist in the design of more efficient air distribution systems within passenger aircraft cabins where there is a need to optimize the air flow in order to efficiently improve aircraft passengers' thermal comfort and reduce energy use. PMID:25479988

  14. DUCT RETROFIT STRATEGY TO COMPLEMENT A MODULATING FURNACE.

    SciTech Connect

    ANDREWS,J.W.

    2002-10-02

    Some recent work (Walker 2001, Andrews 2002) has indicated that installing a modulating furnace in a conventional duct system may, in many cases, result in a significant degradation in thermal distribution efficiency. The fundamental mechanism was pointed out nearly two decades ago (Andrews and Krajewski 1985). The problem occurs in duct systems that are less-than-perfectly insulated (e.g., R-4 duct wrap) and are located outside the conditioned space. It stems from the fact that when the airflow rate is reduced, as it will be when the modulating furnace reduces its heat output rate, the supply air will have a longer residence time in the ducts and will therefore lose a greater percentage of its heat by conduction than it did at the higher airflow rate. The impact of duct leakage, on the other hand, is not expected to change very much under furnace modulation. The pressures in the duct system will be reduced when the airflow rate is reduced, thus reducing the leakage per unit time. This is balanced by the fact that the operating time will increase in order to meet the same heating load as with the conventional furnace operating at higher output and airflow rates. The balance would be exact if the exponent in the pressure vs. airflow equation were the same as that in the pressure vs. duct leakage equation. Since the pressure-airflow exponent is usually {approx}0.5 and the pressure-leakage exponent is usually {approx}0.6, the leakage loss as a fraction of the load should be slightly lower for the modulating furnace. The difference, however, is expected to be small, determined as it is by a function with an exponent equal to the difference between the above two exponents, or {approx}0.1. The negative impact of increased thermal conduction losses from the duct system may be partially offset by improved efficiency of the modulating furnace itself. Also, the modulating furnace will cycle on and off less often than a single-capacity model, and this may add a small amount

  15. A tracer method for quantifying contamination of building supply air: reentrainment of laboratory hood exhausts.

    PubMed

    Barnett, J L; Richard, M L; Rose, V E

    1983-08-01

    A method is described for quantifying the reentrainment of exhaust air contaminants into a building's fresh-air supply system. The method relies on the "tracer" gas, sulfur hexafluoride (SF6), which Is detected by infrared (IR) absorption analysis. This method of analysis differs from the conventional gas chromatography, electron capture detection method due to the MIRAN-1 A's portability, direct-reading capabilities, ease of operation and modest cost. Specific instrument settings for the MIRAN-1 A are given such that detection of SF6 will be optimized without interference. Calculations for quantifying reentrainment are presented and discussed for the "worst case" reentrainment observed. PMID:6624644

  16. Experimental investigation on a turbine compressor for air supply system of a fuel cell

    SciTech Connect

    Matsuda, Masayasu; Tsuchiyama, Syozo

    1996-12-31

    This report covers part of a joint study on a PEFC propulsion system for surface ships, summarized in a presentation to this Seminar, entitled {open_quotes}Study on a Polymer Electrolyte Fuel Cell (PEFC) Propulsion System for Surface Ships{close_quotes}, and which envisages application to a 1,500 DWT cargo vessel. The aspect treated here concerns a study on the air supply system for the PEFC, with particular reference to system components.

  17. Risk of sick leave associated with outdoor air supply rate, humidification, and occupant complaints.

    PubMed

    Milton, D K; Glencross, P M; Walters, M D

    2000-12-01

    We analyzed 1994 sick leave for 3,720 hourly employees of a large Massachusetts manufacturer, in 40 buildings with 115 independently ventilated work areas. Corporate records identified building characteristics and IEQ complaints. We rated ventilation as moderate (approximately 25 cfm/person, 12 ls-1) or high (approximately 50 cfm/person, 24 ls-1) outdoor air supply based on knowledge of ventilation systems and CO2 measurements on a subset of work areas, and used Poisson regression to analyze sick leave controlled for age, gender, seniority, hours of non-illness absence, shift, ethnicity, crowding, and type of job (office, technical, or manufacturing worker). We found consistent associations of increased sick leave with lower levels of outdoor air supply and IEQ complaints. Among office workers, the relative risk for short-term sick leave was 1.53 (95% confidence 1.22-1.92) with lower ventilation, and 1.52 (1.18-1.97) in areas with IEQ complaints. The effect of ventilation was independent of IEQ complaints and among those exposed to lower outdoor air supply rates the attributable risk of short-term sick leave was 35%. The cost of sick leave attributable to ventilation at current recommended rates was estimated as $480 per employee per year at Polaroid. These findings suggest that net savings of $400 per employee per year may be obtained with increased ventilation. Thus, currently recommended levels of outdoor air supply may be associated with significant morbidity, and lost productivity on a national scale could be as much as $22.8 billion per year. Additional studies of IEQ impacts on productivity and sick leave, and the mechanisms underlying the apparent association are needed. PMID:11089326

  18. Development of a method for the regeneration of an alkaline electrolyte in an air-aluminum chemical power supply

    NASA Astrophysics Data System (ADS)

    Pushkin, K. V.; Sevruk, S. D.; Suvorova, E. V.; Farmakovskaya, A. A.

    2015-12-01

    The results of studying the development of a regeneration technology for the spent alkaline electrolyte in an air-aluminum chemical power supply are presented. The application of this technology is a component of the wasteless and friendly environmental operation of an energy installation based on an air-aluminum chemical power supply. The operability of the energy installation based on the air-aluminum chemical power supply using regenerated alkaline electrolytes is experimentally confirmed. Technical requirements for the technological equipment for alkaline electrolyte regeneration are developed on the basis of the obtained results.

  19. Biofiltration of air contaminated by styrene: Effect of nitrogen supply, gas flow rate, and inlet concentration

    SciTech Connect

    Jorio, H.; Bibeau, L.; Heitz, M.

    2000-05-01

    The biofiltration process is a promising technology for the treatment of dilute styrene emissions in air. The efficiency of this process is however strongly dependent upon various operational parameters such as the filter bed characteristics, nutrient supplies, input contaminant concentrations, and gas flow rates. The biofiltration of air containing styrene vapors was therefore investigated, employing a novel biomass filter material, in two identical but separate laboratory scale biofiltration units (units 1 and 2), both biofilters being initially inoculated with a microbial consortium. Each biofilter was irrigated with a nutrient solution supplying nitrogen in one of two forms; i.e., mainly as ammonia for unit 1 and exclusively as nitrate for unit 2. The experimental results have revealed that greater styrene elimination rates are achieved in the biofilter supplied with ammonia as the major nitrogen source in comparison to the lesser elimination performance obtained with the nitrate provided biofilter. However, in achieving the high styrene removal rates in the ammonia supplied biofilter, the excess of biomass accumulates on the filtering pellets and causes progressive clogging of the filter media. Furthermore, the effectiveness of nitrate supply as the sole nitrogen nutrient form, on reducing or controlling the biomass accumulation in the filter media in comparison to ammonia, could not be satisfactorily demonstrated because the two biofilters operated with very different styrene elimination capacities. The monitoring of the carbon dioxide concentration profile through both biofilters revealed that the ratio of carbon dioxide produced to the styrene removed was approximately 3/1, which confirms the complete biodegradation of removed styrene, given that some of the organic carbon consumed is also used for the microbial growth. The effects of the most important design parameters, namely styrene input concentrations and gas flow rates, were investigated for each

  20. Potential Impact of the National Plan for Future Electric Power Supply on Air Quality in Korea

    NASA Astrophysics Data System (ADS)

    Shim, C.; Hong, J.

    2014-12-01

    Korean Ministry of Trade, Industry and Energy (MOTIE) announced the national plan for Korea's future electric power supply (2013 - 2027) in 2013. According to the plan, the national demand for electricity will be increased by 60% compared to that of 2010 and primary energy sources for electric generation will still lean on the fossil fuels such as petroleum, LNG, and coal, which would be a potential threat to air quality of Korea. This study focused on two subjects: (1) How the spatial distribution of the primary air pollutant's emissions (i.e., NOx, SOx, CO, PM) will be changed and (2) How the primary emission changes will influence on the national ambient air quality including ozone in 2027. We used GEOS-Chem model simulation with modification of Korean emissions inventory (Clean Air Policy Support System (CAPSS)) to simulate the current and future air quality in Korea. The national total emissions of CO, NOx, SOx, PM in year 2027 will be increased by 3%, 8%, 13%, 2%, respectively compared to 2010 and there are additional concern that the future location of the power plants will be closer to the Seoul Metropolitan Area (SMA), where there are approximately 20 million population vulnerable to the potentially worsened air quality. While there are slight increase of concentration of CO, NOx, SOx, and PM in 2027, the O3 concentration is expected to be similar to the level of 2010. Those results may imply the characteristics of air pollution in East Asia such as potentially severe O3 titration and poorer O3/CO or O3/NOx ratio. Furthermore, we will discuss on the impact of transboundary pollution transport from China in the future, which is one of the large factors to control the air quality of Korea.

  1. Low-cost orbiting grinder for cutting ducts

    NASA Technical Reports Server (NTRS)

    Lang, E. J.

    1970-01-01

    Low-cost, portable machine cuts ducts made from heat-treated alloys. An abrasive wheel, powered by a high-speed air motor mounted on an expandible plug against the inner wall of the duct, gives precise cutting.

  2. Influence of atmospheric pressure supplied on permittivity of air-film of aerostatic bearing

    NASA Astrophysics Data System (ADS)

    Li, Min; Zhang, Yubing; Li, Dong-sheng

    2013-01-01

    Influence of atmospheric pressure supplied on permittivity of the air-film is researched based on the capacitive testing method of the air film thickness of aerostatic bearing. An experiment platform is designed. The experimental results illustrate that permittivity has significant negative correlation with atmospheric pressure which varies from 0.1MPa to 0.48MPa when other environmental conditions remain unchanged. The curves conform to the fourth-order polynomial approximately. All of the values of R2 are beyond 0.944 which means that trend lines fit the data curves well. Relative permittivity of the air film is between 0.996 and 1.324. This interval shows that weak current exists between restrictor and flat of the experiment which are not absolutely insulating and atmosphere of the air film is not pure. This result provides a basis both for establishing accurate mathematical model of air film thickness and capacitance value of the aerostatic bearing and for other exploratory experiments later.

  3. Heat Transfer Enhancement in a Solar Air Heater with Roughened Duct Having Arc-Shaped Elements as Roughness Element on the Absorber Plate

    NASA Astrophysics Data System (ADS)

    Singh, Anil Prakash; Goel, Varun; Vashishtha, Siddhartha; Kumar, Amit

    2016-07-01

    An experimental study has been carried out for the heat transfer and friction characteristics for arc shaped roughness element used in solar air heaters. Duct has an aspect ratio (W/H) of 11, relative roughness pitch (p/e) range of 4-16, relative roughness height (e/D) range of 0.027-0.045, Reynolds number ( Re) range of 2200-22,000 and arc angle (α) was kept constant at 60°. The effects of Re, relative roughness pitch (p/e) and relative roughness height (e/D) on heat transfer and friction factor have been discussed. The results obtained for Nusselt number and friction factor has been compared with smooth solar air heater to see the enhancement in heat transfer and friction factor and it is found out that considerable enhancement takes place in case of heat transfer as well as in friction factor. Correlations were also developed for Nusselt number and friction factor. Thermo-hydraulic performance parameter is also calculated for the same.

  4. Heat Transfer Enhancement in a Solar Air Heater with Roughened Duct Having Arc-Shaped Elements as Roughness Element on the Absorber Plate

    NASA Astrophysics Data System (ADS)

    Singh, Anil Prakash; Goel, Varun; Vashishtha, Siddhartha; Kumar, Amit

    2016-05-01

    An experimental study has been carried out for the heat transfer and friction characteristics for arc shaped roughness element used in solar air heaters. Duct has an aspect ratio (W/H) of 11, relative roughness pitch (p/e) range of 4-16, relative roughness height (e/D) range of 0.027-0.045, Reynolds number (Re) range of 2200-22,000 and arc angle (α) was kept constant at 60°. The effects of Re, relative roughness pitch (p/e) and relative roughness height (e/D) on heat transfer and friction factor have been discussed. The results obtained for Nusselt number and friction factor has been compared with smooth solar air heater to see the enhancement in heat transfer and friction factor and it is found out that considerable enhancement takes place in case of heat transfer as well as in friction factor. Correlations were also developed for Nusselt number and friction factor. Thermo-hydraulic performance parameter is also calculated for the same.

  5. Minimizing Thermal Deformation of Aerostatic Spindle System by Temperature Control of Supply Air

    NASA Astrophysics Data System (ADS)

    Yoshioka, Hayato; Matsumura, Shimpei; Hashizume, Hitoshi; Shinno, Hidenori

    Aerostatic spindle systems have been widely used in many machine tools due to their low heat generation and high-speed capability. To meet industrial demands for higher accuracy and higher productivity, such spindle systems have recently become important as the kernel component in an ultraprecision machine tool. In this study, therefore, thermal deformation control for aerostatic spindle systems has been proposed considering heat balance in an objective spindle bearing system. In the proposed method, the temperature of supply air is controlled by monitoring that of exhaust air to minimize the thermal deformation of the spindle. The performance of the thermal deformation control system developed has been evaluated through a series of actual experiments.

  6. Solid reaction products and aluminate solutions that form during the operation of an air-aluminum chemical power supply

    NASA Astrophysics Data System (ADS)

    Okorokova, N. S.; Sevruk, S. D.; Suvorova, E. V.; Farmakovskaya, A. A.

    2015-12-01

    A solution to the set of problems concerning the solid reaction products and the aluminate solutions that form during the operation of an aluminum-closed power supply system for self-contained objects is proposed. The system is based on a resource-saving technology using an aluminum energy carrier in an air-aluminum chemical power supply and related energy installations. The boundaries of the metastable and labile state regions of aluminate solutions and the real degrees of supersaturation that can be attained when aluminum is dissolved in an electrolyte during the operation of an air-aluminum chemical power supply are determined.

  7. Repair of Corrosion in Air Supply Piping at the NASA Glenn Research Center's 1 by 1 Foot Supersonic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Henry, Michael

    2000-01-01

    During a test at the NASA Glenn Research Center's 1 x 1 Supersonic Wing Tunnel, it was discovered that particles entrained in the air flow were damaging the pressure sensitive paint on a test article. An investigation found the source of the entrained particles to be rust on the internal surfaces of the air supply piping. To remedy the situation, the air supply line components made from carbon steel were either refurbished or replaced with new stainless steel components. The refurbishment process included various combinations of chemical cleaning, bead blasting, painting and plating.

  8. LABORATORY EVALUATION OF THE DELTA Q TEST FOR DUCT LEAKAGE

    SciTech Connect

    ANDREWS,J.W.

    2003-05-01

    Using a residential-size duct system in a controlled laboratory setting, the repeatability and accuracy of the Delta Q test for air leakage in residential duct systems have been measured. More than 100 Delta Q tests were performed. These were compared with results using fan pressurization and also with results of a procedure (Delta Q Plus) that uses leakage hole-size information to select the leakage pressures to be used in the Delta Q algorithm. The average error in supply or return leakage for the fan-pressurization test was 6.4% of system fan flow. For the Delta Q test it was 3.4% of fan flow, while for Delta Q Plus it was 1.9% of fan flow.

  9. Reducing Uncertainty for the DeltaQ Duct Leakage Test

    SciTech Connect

    Walker, Iain S.; Sherman, Max H.; Dickerhoff, Darryl J.

    2004-05-01

    The thermal distribution system couples the HVAC components to the building envelope, and shares many properties of the buildings envelope including moisture, conduction and most especially air leakage performance. Duct leakage has a strong influence on air flow rates through building envelopes (usually resulting in much greater flows than those due to natural infiltration) because unbalanced duct air flows and leaks result in building pressurization and depressurization. As a tool to estimate this effect, the DeltaQ duct leakage test has been developed over the past several years as an improvement to existing duct pressurization tests. It focuses on measuring the air leakage flows to outside at operating conditions that are required for envelope infiltration impacts and energy loss calculations for duct systems. The DeltaQ test builds on the standard envelope tightness blower door measurement techniques by repeating the tests with the system air handler off and on. The DeltaQ test requires several assumptions to be made about duct leakage and its interaction with the duct system and building envelope in order to convert the blower door results into duct leakage at system operating conditions. This study examined improvements to the DeltaQ test that account for some of these assumptions using a duct system and building envelope in a test laboratory. The laboratory measurements used a purpose-built test chamber coupled to a duct system typical of forced air systems in US homes. Special duct leaks with controlled air-flow were designed and installed into an airtight duct system. This test apparatus allowed the systematic variation of the duct and envelope leakage and accurate measurement of the duct leakage flows for comparison to DeltaQ test results. This paper will discuss the laboratory test apparatus design, construction and operation, the various analysis techniques applied to the calculation procedure and present estimates of uncertainty in measured duct

  10. Investigation of the use of fly-ash based autoclaved cellular concrete blocks in coal mines for air duct work. Final report, January 25, 1993--December 31, 1994

    SciTech Connect

    Horvath, M.L.

    1995-06-19

    Coal mines are required to provide ventilation to occupied portions of underground mines. Concrete block is used in this process to construct air duct walls. However, normal concrete block is heavy and not easy to work with and eventually fails dramatically after being loaded due to mine ceiling convergence and/or floor heave. Autoclaved cellular concrete block made from (70{plus_minus}%) coal fly ash is lightweight and less rigid when loaded. It is lighter and easier to use than regular concrete block for underground mine applications. It has also been used in surface construction around the world for over 40 years. Ohio Edison along with eight other electric utility companies, the Electric Power Research Institute (EPRI), and North American Cellular Concrete constructed a mobile demonstration plant to produce autoclaved cellular concrete block from utility fly ash. To apply this research in Ohio, Ohio Edison also worked with the Ohio Coal Development Office and CONSOL Inc. to produce autoclaved cellular concrete block not only from coal ash but also from LIMB ash, SNRB ash, and PFBC ash from various clean coal technology projects sponsored by the Ohio Coal Development Office. The purpose of this project was to demonstrate the potential for beneficial use of fly ash and clean coal technology by-products in the production of lightweight block.

  11. BTS Fact Sheet: Improving the efficiency of your duct system

    SciTech Connect

    BNL

    1999-12-28

    The duct system, used in air heating and air cooling your home, is a collection of tubes that distributes the heated or cooled air to the various rooms. The duct system can have an important effect on health of the occupants through the distribution of indoor air pollution. Changes and repairs to a duct system should always be performed by a qualified professional. This brochure is meant to help you understand the problems that can affect the duct system and how you can save money, improve comfort, and protect against potential health hazards.

  12. Experimental study of wood downdraft gasification for an improved producer gas quality through an innovative two-stage air and premixed air/gas supply approach.

    PubMed

    Jaojaruek, Kitipong; Jarungthammachote, Sompop; Gratuito, Maria Kathrina B; Wongsuwan, Hataitep; Homhual, Suwan

    2011-04-01

    This study conducted experiments on three different downdraft gasification approaches: single stage, conventional two-stage, and an innovative two-stage air and premixed air/gas supply approach. The innovative two-stage approach has two nozzle locations, one for air supply at combustion zone and the other located at the pyrolysis zone for supplying the premixed gas (air and producer gas). The producer gas is partially bypassed to mix with air and supplied to burn at the pyrolysis zone. The result shows that producer gas quality generated by the innovative two-stage approach improved as compared to conventional two-stage. The higher heating value (HHV) increased from 5.4 to 6.5 MJ/Nm(3). Tar content in producer gas reduced to less than 45 mg/Nm(3). With this approach, gas can be fed directly to an internal combustion engine. Furthermore, the gasification thermal efficiency also improved by approximately 14%. The approach gave double benefits on gas qualities and energy savings. PMID:21292477

  13. Gas Engine-Driven Heat Pump Chiller for Air-Conditioning and Hot Water Supply Systems

    NASA Astrophysics Data System (ADS)

    Fujita, Toshihiko; Mita, Nobuhiro; Moriyama, Tadashi; Hoshino, Norimasa; Kimura, Yoshihisa

    In Part 1 of this study, the performance characteristics of a 457kW gas engine-driven heat pump (GHP) chiller have been obtained from a simulation model analysis for both cooling and heating modes and it has been found that the part-load characteristics of the GHP chiller are fairly well. On the back of Part 1, a computer simulation program has been developed for the evaluation of GHP chiller systems to compare with the other types of heat source systems for air-conditioning and hot water supply applications. The simulation program can be used to estimate annual energy consumption, annual CO2 emission, etc. of the systems with the data of monthly and hourly thermal loads on various buildings, outdoor air conditions, and characteristics of various components comprising the systems. By applying this to some cases of medium-scale hotel, office, shop, and hospital buildings, it has been found that the GHP chiller systems have advantages particularly in the cases of hotels and hospitals where a lot of hot water demand exists. It has also been found that the combination of a GHP chiller and a direct-fired absorption water chiller boiler (hot and chilled water generator) appears promising.

  14. INTERIOR DUCT SYSTEM DESIGN, CONSTRUCTION, AND PERFORMANCE

    SciTech Connect

    Janet E.R. Mcllvaine; David Beal; Philip Fairey

    2001-10-10

    By removing air distribution and conditioning equipment from unconditioned spaces, homeowners stand to benefit substantially with respect to both energy savings and indoor air quality. Duct leakage introduces: Greater heating and cooling loads from air at extreme temperatures and humidity levels; Outside air and air from unconditioned spaces that may contain air borne contaminants, combustion gases, pollen, mold spores, and/or particles of building materials; and Higher whole-house infiltration/exfiltration rates. Exemplary studies conducted since 1990 have demonstrated the prevalence of duct leakage throughout the United States and measured energy savings of approximately 20% during both heating and cooling seasons from leakage reduction. These all dealt with duct leakage to and/or from unconditioned spaces. In the building science community, leakage within the conditioned space is generally presumed to eliminate the negative consequences of duct leakage with the exception of possibly creating pressure imbalances in the house which relates to higher infiltration and/or exfiltration. The practical challenges of isolating ducts and air handlers from unconditioned spaces require builders to construct an air-tight environment for the ducts. Florida Solar Energy Center researchers worked with four builders in Texas, North Carolina, and Florida who build a furred-down chase located either in a central hallway or at the edges of rooms as an architectural detail. Some comparison homes with duct systems in attics and crawl spaces were included in the test group of more than 20 homes. Test data reveals that all of the duct/AHU systems built inside the conditioned space had lower duct leakage to unconditioned spaces than their conventional counterparts; however, none of the homes was completely free of duct leakage to unconditioned spaces. Common problems included wiring and plumbing penetrations of the chase, failure to treat the chase as an air tight space, and misguided

  15. Flue gas duct assembly

    SciTech Connect

    Montana, F.J.

    1984-08-28

    A length of longitudinally extending duct assembly for heated corrosive gases includes an outer support duct and a substantially gas-tight liner. The liner is spaced from the outer support duct by a relatively yielding spacer material that accommodates expansion of the liner in directions parallel to the inner surface of the outer support duct and in directions normal to the inner surface of the outer support duct without imposing any substantial resistance to such thermal expansion.

  16. Strategy Guideline: Compact Air Distribution Systems

    SciTech Connect

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  17. 42 CFR 84.156 - Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  18. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  19. 42 CFR 84.154 - Airflow resistance test; Type B and Type BE supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type B and Type BE..., DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.154 Airflow resistance test;...

  20. 42 CFR 84.159 - Man tests for gases and vapors; supplied-air respirators; general performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  1. 42 CFR 84.159 - Man tests for gases and vapors; supplied-air respirators; general performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  2. 42 CFR 84.159 - Man tests for gases and vapors; supplied-air respirators; general performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  3. 42 CFR 84.159 - Man tests for gases and vapors; supplied-air respirators; general performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  4. 42 CFR 84.159 - Man tests for gases and vapors; supplied-air respirators; general performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE...

  5. 42 CFR 84.149 - Type C supplied-air respirator, demand and pressure demand class; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Type C supplied-air respirator, demand and pressure demand class; minimum requirements. 84.149 Section 84.149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES...

  6. Building America Top Innovations 2012: Integration of HVAC System Design with Simplified Duct Distribution

    SciTech Connect

    none,

    2013-01-01

    This Building America Top Innovations profile describes work by Building America research teams who field tested simplified duct designs in hundreds of homes, confirming the performance of short compact duct runs, with supply registers near interior walls.

  7. Particle deposition in ventilation ducts: Connectors, bends anddeveloping flow

    SciTech Connect

    Sippola, Mark R.; Nazaroff, William W.

    2004-03-01

    In ventilation duct flow the turbulent flow profile is commonly disturbed or not fully developed and these conditions are likely to influence particle deposition to duct surfaces. Particle deposition rates at eight S-connectors, in two 90{sup o} duct bends and in two ducts where the turbulent flow profile was not fully developed were measured in a laboratory duct system with both galvanized steel and internally insulated ducts with hydraulic diameters of 15.2 cm. In the steel duct system, experiments with nominal particle diameters of 1, 3, 5, 9 and 16 {micro}m were conducted at each of three nominal air speeds: 2.2, 5.3 and 9.0 m/s. In the insulated duct system, deposition of particles with nominal diameters of 1, 3, 5, 8 and 13 {micro}m was measured at nominal air speeds of 2.2, 5.3 and 8.8 m/s. Fluorescent techniques were used to directly measure the deposition velocities of monodisperse fluorescent particles to duct surfaces. Deposition at S-connectors, in bends and in straight ducts with developing turbulence was often greater than deposition in straight ducts with fully developed turbulence for equal particle sizes, air speeds and duct surface orientations. Deposition rates at all locations were found to increase with an increase in particle size or air speed. High deposition rates at S-connectors resulted from impaction and these rates were nearly independent of the orientation of the S-connector. Deposition rates in the two 90{sup o} bends differed by more than an order of magnitude in some cases, probably because of the difference in turbulence conditions at the bend inlets. In straight steel ducts where the turbulent flow profile was developing, the deposition enhancement relative to fully developed turbulence generally increased with air speed and decreased with downstream distance from the duct inlet. This enhancement was greater at the duct ceiling and wall than at the duct floor. In insulated ducts, deposition enhancement was less pronounced overall

  8. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    ERIC Educational Resources Information Center

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  9. 91. VIEW OF OBSOLETE AIRCONDITIONING DUCTS LOCATED IN NORTHWEST CORNER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    91. VIEW OF OBSOLETE AIR-CONDITIONING DUCTS LOCATED IN NORTHWEST CORNER OF ROOM, ABOVE SLC-3E AUTOPILOT EQUIPMENT. DIGITAL COUNTDOWN AND HOLD CLOCKS ON WALL LEFT OF DUCTS - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  10. 54. DETAIL OF AIRCONDITIONING EXHAUST DUCTS ON NORTH FACE OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    54. DETAIL OF AIR-CONDITIONING EXHAUST DUCTS ON NORTH FACE OF ERECT UMBILICAL MAST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  11. Propagation Of Sound In Curved Ducts

    NASA Technical Reports Server (NTRS)

    Rostafinski, Wojciech

    1992-01-01

    Monograph presents concise, comprehensive summary of knowledge of propagation of acoustic waves in ducts and pipes including bends. Pulls together information from Lord Rayleigh's book Theory Of Sound, published in 1878, and from 33 papers scattered throughout various scientific journals published between 1945 and 1989. Monograph useful to scientists and engineers interested in such diverse topics as musical instruments, air-conditioning ducts, and jet engines. Material not available in current texts.

  12. Effect of car speed on amount of air supplied by ventilation system to the space of car cabin

    NASA Astrophysics Data System (ADS)

    Fišer, Jan; Pokorný, Jan

    2014-03-01

    The amount of air supplied by ventilation system (HVAC system) of a car into a cabin is one of the main parameters for the correct simulation and prediction of a car cabin heat load. This amount is not based only on the current setting of the HVAC system, but also on the actual operating conditions and speed of the car. The authors therefore carried out experiments in the cabin of a passenger car in real traffic, while observing the amount of air on the speed of the car and setting of flap in mixing chamber. In a subsequent analysis the authors defined dependence of the airflow rate supplied by HVAC system on the speed of the car. Obtained empirical formulas were then used as a part of the code which calculates the data for the HVAC boundary conditions in the simulation of the car cabin environment.

  13. Strategy Guideline. Compact Air Distribution Systems

    SciTech Connect

    Burdick, Arlan

    2013-06-01

    This guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  14. Occupational Choice, The Draft, and the Excess Supply of Air Force Volunteers.

    ERIC Educational Resources Information Center

    Cook, Alvin A., Jr.

    A mathematical model was developed of military enlistment behavior based on the principle of occupational choice. A quality adjustment, applicable to all labor markets, was incorporated into the model in estimating the supply of volunteers. It was assumed that the greater the excess supply of volunteers, the greater the average quality of…

  15. Contributing recharge areas to water-supply wells at Wright-Patterson Air Force Base, Ohio

    USGS Publications Warehouse

    Sheets, R.A.

    1994-01-01

    Wright-Patterson Air Force Base, in southwestern Ohio, has operated three well fields--Area B, Skeel Road, and the East Well Fields--to supply potable water for consumption and use for base activities. To protect these well fields from contamination and to comply with the Ohio Wellhead Protection Plan, the Base is developing a wellhead-protection program for the well fields. A three-dimensional, steady-state ground-water-flow model was developed in 1993 to simulate heads in (1) the buried-valley aquifer system that is tapped by the two active well fields, and in (2) an upland bedrock aquifer that may supply water to the wells. An advective particle-tracking algorithm that requires estimated porosities and simulated heads was used to estimate ground-water-flow pathlines and traveltimes to the active well fields. Contributing recharge areas (CRA's)--areas on the water table that contribute water to a well or well field--were generated for 1-, 5-, and 10-year traveltimes. Results from the simulation and subsequent particle tracking indicate that the CRA's for the Skeel Road Well Fields are oval and extend north- ward, toward the Mad River, as pumping at the well field increases. The sizes of the 1-, 5-, and 10-year CRA's of Skeel Road Well Field, under maximum pumping conditions, are approximately 0.5, 1.5 and 3.2 square miles, respectively. The CRA's for the Area B Well Field extend to the north, up the Mad River Valley; as pumping increases at the well field, the CRA's extend up the Mad River Valley under Huffman Dam. The sizes of the 1-, 5-, and 10-year CRA's of Area B Well Field, under maximum pumping conditions, are approximately 0.1, 0.5, and 0.9 square miles, respectively. The CRA's for the East Well Field are affected by nearby streams under average pumping conditions. The sizes of the 1-, 5-, and 10-year CRA's of the East Well Field, under maximum pumping conditions, are approximately 0.2, 1.2, and 2.4 square miles, respectively. However, as pumping increases

  16. 24 CFR 3280.715 - Circulating air systems.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... inches of water or greater. (See § 3280.511). (ii) The refrigerated air cooling supply duct system... greater than 0.3 inches of water when measured at room temperature. In the case of application of external... water manometer or equivalent device calibrated to read in increments not greater than 1/10 inch...

  17. 24 CFR 3280.715 - Circulating air systems.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... inches of water or greater. (See § 3280.511). (ii) The refrigerated air cooling supply duct system... greater than 0.3 inches of water when measured at room temperature. In the case of application of external... water manometer or equivalent device calibrated to read in increments not greater than 1/10 inch...

  18. 24 CFR 3280.715 - Circulating air systems.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... inches of water or greater. (See § 3280.511). (ii) The refrigerated air cooling supply duct system... greater than 0.3 inches of water when measured at room temperature. In the case of application of external... water manometer or equivalent device calibrated to read in increments not greater than 1/10 inch...

  19. 24 CFR 3280.715 - Circulating air systems.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... inches of water or greater. (See § 3280.511). (ii) The refrigerated air cooling supply duct system... greater than 0.3 inches of water when measured at room temperature. In the case of application of external... water manometer or equivalent device calibrated to read in increments not greater than 1/10 inch...

  20. Enhanced performance of an air-cathode microbial fuel cell with oxygen supply from an externally connected algal bioreactor.

    PubMed

    Kakarla, Ramesh; Kim, Jung Rae; Jeon, Byong-Hun; Min, Booki

    2015-11-01

    An algae bioreactor (ABR) was externally connected to air-cathode microbial fuel cells (MFCs) to increase power generation by supplying a high amount of oxygen to cathode electrode. The MFC with oxygen fed from ABR produced maximum cell voltage and cathode potential at a fixed loading of 459 mV and 10 mV, respectively. During polarization analysis, the MFC displayed a maximum power density of 0.63 W/m(2) (at 2.06 A/m(2)) using 39.2% O2 from ABR, which was approximately 30% higher compared with use of atmospheric air (0.44 W/m(2), 20.8% O2,). The cyclic voltammogram analysis exhibited a higher reduction current of -137 mA with 46.5% O2 compared to atmospheric air (-115 mA). Oxygen supply by algae bioreactor to air-cathode MFC could also maintain better MFC performance in long term operation by minimizing cathode potential drop over time. PMID:26188984

  1. A Comparison of Simulation Capabilities for Ducts

    SciTech Connect

    Miller, William A.; Smith, Matt K.; Gu, Lixing; New, Joshua Ryan

    2014-11-01

    Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

  2. Evaluation of DNA damage in exfoliated tear duct epithelial cells from individuals exposed to air pollution assessed by single cell gel electrophoresis assay.

    PubMed

    Rojas, E; Valverde, M; Lopez, M C; Naufal, I; Sanchez, I; Bizarro, P; Lopez, I; Fortoul, T I; Ostrosky-Wegman, P

    2000-06-22

    The search for relevant target cells for human monitoring purposes has increased during the last few years. Cells such as sperm, buccal or nasal and gastric epithelium are being used. In this study, we report the use of exfoliated tear duct epithelial cells as a potential material for human biomonitoring studies, since these cells are a target for environmental pollutants. We employed the alkaline single cell gel electrophoresis (SCGE) assay to evaluate for differences in the basal level of DNA damage between young adults from the south (exposed mainly to high levels of ozone) and from the north (exposed principally to hydrocarbons) regions of Mexico City. We found an increase in DNA migration in tear duct epithelial cells from individuals who live in the southern part of the city compared to those living in the northern part. Moreover, young people who live in the southwest part of the city with the highest values of ozone presented the highest values of DNA damage. These results show the feasibility of using exfoliated tear duct epithelial cells in human biomonitoring studies. PMID:10863153

  3. High cell density cultivation of Pseudomonas putida KT2440 using glucose without the need for oxygen enriched air supply.

    PubMed

    Davis, Reeta; Duane, Gearoid; Kenny, Shane T; Cerrone, Federico; Guzik, Maciej W; Babu, Ramesh P; Casey, Eoin; O'Connor, Kevin E

    2015-04-01

    High Cell Density (HCD) cultivation of bacteria is essential for the majority of industrial processes to achieve high volumetric productivity (g L(-1) h(-1) ) of a bioproduct of interest. This study developed a fed batch bioprocess using glucose as sole carbon and energy source for the HCD of the well described biocatalyst Pseudomonas putida KT2440 without the supply of oxygen enriched air. Growth kinetics data from batch fermentations were used for building a bioprocess model and designing feeding strategies. An exponential followed by linearly increasing feeding strategy of glucose was found to be effective in maintaining biomass productivity while also delaying the onset of dissolved oxygen (supplied via compressed air) limitation. A final cell dry weight (CDW) of 102 g L(-1) was achieved in 33 h with a biomass productivity of 3.1 g L(-1) h(-1) which are the highest ever reported values for P. putida strains using glucose without the supply of pure oxygen or oxygen enriched air. The usefulness of the biomass as a biocatalyst was demonstrated through the production of the biodegradable polymer polyhydroxyalkanoate (PHA). When nonanoic acid (NA) was supplied to the glucose grown cells of P. putida KT2440, it accumulated 32% of CDW as PHA in 11 h (2.85 g L(-1) h(-1) ) resulting in a total of 0.56 kg of PHA in 18 L with a yield of 0.56 g PHA g NA(-1) . PMID:25311981

  4. Numerical simulation of duct flow with fog droplets

    NASA Astrophysics Data System (ADS)

    Suryan, Abhilash; Lee, J. K.; Kim, D. S.; Kim, H. D.

    2010-12-01

    Evaporative cooling is a widely used air cooling technique. In this method, evaporation of a liquid in the surrounding air cools the air in contact with it. In the current investigation, numerical simulations are carried out to visualize the evaporation and dynamics of tiny water droplets of different diameters in a long air duct. The effect of initial droplet size on the temperature and relative humidity distribution of the air stream in the duct is investigated. Three different initial conditions of air are considered to verify the influence of ambient conditions. Droplet spray patterns are also analyzed to identify the suitable locations for the spray nozzles within the duct. The results obtained are displayed in a series of plots to provide a clear understanding of the evaporative cooling process as well as the droplet dynamics within the ducts.

  5. Lightweight Valve Closes Duct Quickly

    NASA Technical Reports Server (NTRS)

    Fournier, Walter L.; Burgy, N. Frank

    1991-01-01

    Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

  6. Experiments measuring particle deposition from fully developed turbulent flow in ventilation ducts

    SciTech Connect

    Sippola, Mark R.; Nazaroff, William W.

    2003-08-01

    Particle deposition in ventilation ducts influences particle exposures of building occupants and may lead to a variety of indoor air quality concerns. Experiments have been performed in a laboratory to study the effects of particle size and air speed on deposition rates of particles from turbulent air flows in galvanized steel and internally insulated ducts with hydraulic diameters of 15.2 cm. The duct systems were constructed of materials typically found in commercial heating, ventilating and air conditioning (HVAC) systems. In the steel duct system, experiments with nominal particle sizes of 1, 3, 5, 9 and 16 {micro}m were conducted at each of three nominal air speeds: 2.2, 5.3 and 9.0 m/s. In the insulated duct system, deposition rates of particles with nominal sizes of 1, 3, 5, 8 and 13 {micro}m were measured at nominal air speeds of 2.2, 5.3 and 8.8 m/s. Fluorescent techniques were used to directly measure the deposition velocities of monodisperse fluorescent particles to duct surfaces (floor, wall and ceiling) at two straight duct sections where the turbulent flow profile was fully developed. In steel ducts, deposition rates were higher to the duct floor than to the wall, which were, in turn, greater than to the ceiling. In insulated ducts, deposition was nearly the same to the duct floor, wall and ceiling for a given particle size and air speed. Deposition to duct walls and ceilings was greatly enhanced in insulated ducts compared to steel ducts. Deposition velocities to each of the three duct surface orientations in both systems were found to increase with increasing particle size or air velocity over the ranges studied. Deposition rates measured in the current experiments were in general agreement with the limited observations of similar systems by previous researchers.

  7. SNM holdup assessment of Los Alamos exhaust ducts. Final report

    SciTech Connect

    Marshall, R.S.

    1994-02-01

    Fissile material holdup in glovebox and fume hood exhaust ducting has been quantified for all Los Alamos duct systems. Gamma-based, nondestructive measurements were used to quantify holdup. The measurements were performed during three measurement campaigns. The first campaign, Phase I, provided foot-by-foot, semiquantitative measurement data on all ducting. These data were used to identify ducting that required more accurate (quantitative) measurement. Of the 280 duct systems receiving Phase I measurements, 262 indicated less than 50 g of fissile holdup and 19 indicated fissile holdup of 50 or more grams. Seven duct systems were measured in a second campaign, called Series 1, Phase II. Holdup estimates on these ducts ranged from 421 g of {sup 235}U in a duct servicing a shut-down uranium-machining facility to 39 g of {sup 239}Pu in a duct servicing an active plutonium-processing facility. Measurements performed in the second campaign proved excessively laborious, so a third campaign was initiated that used more efficient instrumentation at some sacrifice in measurement quality. Holdup estimates for the 12 duct systems measured during this third campaign ranged from 70 g of {sup 235}U in a duct servicing analytical laboratories to 1 g of {sup 235}U and 1 g of {sup 239}Pu in a duct carrying exhaust air to a remote filter building. These quantitative holdup estimates support the conclusion made at the completion of the Phase I measurements that only ducts servicing shut-down uranium operations contain about 400 g of fissile holdup. No ventilation ducts at Los Alamos contain sufficient fissile material holdup to present a criticality safety concern.

  8. Ducted auroral kilometric radiation

    NASA Technical Reports Server (NTRS)

    Calvert, W.

    1982-01-01

    Certain discrete, intense wave signals attributed to auroral kilometric radiation (AKR) were observed with ISEE-l while it was within the plasmaspheric shadow zone for direct propagation. It is believed that wave ducting by thin depletions of the plasma density aligned with the magnetic field accounts for such signals, and that their discrete nature is caused by the satellite intercepting individual ducts. These ducts, which were also observed as coincident decreases of the upper hybrid resonance frequency, appeared to be twenty-percent depletions roughly one hundred kilometers across. The AKR, which is emitted approximately perpendicular to the magnetic field, apparently entered these ducts equatorward of the source after the waves had been refracted parallel to the duct axis. A diffuse background was also observed which is consistent with the leakage from similar ducts at lower L-values. These observations establish the existence of ducted AKR, its signature on the satellite wave spectrograms, and new evidence for depletion ducts within the plasmasphere.

  9. Comparison of various methods to distribute supply air in industrial facilities

    SciTech Connect

    Kirkpatrick, A.T.; Strobel, K.

    1999-07-01

    The evaluation of the ventilation effectiveness and thermal comfort for various industrial ventilation schemes has been carried out by scale model experimentation. Forty experiments involving ten ventilation arrangements, each with three supply airflow rates and two possible industrial process heat loads, were performed. Measurements of airspeed, temperature, and contaminant concentration allowed the thermal comfort and contaminant removal to be quantified using the ISO Comfort Standard ISO-7730 and the ventilation effectiveness indices, respectively. Archimedes number scaling was used to convert the small-scale measurements to full-scale conditions. The largest ventilation effectiveness occurred for a low supply/high return configuration, with values above 1.6, followed by a high supply/high return configuration with values in the range from 1.0 to 1.2. A low supply/low return configuration had values of about 1.0. The ventilation efficiency generally increased when the heat load was increased and/or the flow rate decreased. Increasing the number of diffusers in the occupied zone increased the ventilation effectiveness. The thermal comfort results depended on the diffuser configuration and the activity level of the worker. Most of the configurations produced acceptable thermal comfort results for a seated worker and unacceptable conditions at an increased activity and clothing level.

  10. Duct Leakage Repeatability Testing

    SciTech Connect

    Walker, Iain; Sherman, Max

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  11. Downhole steam generator using low-pressure fuel and air supply

    DOEpatents

    Fox, R.L.

    1981-01-07

    For tertiary oil recovery, an apparatus for downhole steam generation is designed in which water is not injected directly onto the flame in the combustor, the combustion process is isolated from the reservoir pressure, the fuel and oxidant are supplied to the combustor at relatively low pressures, and the hot exhaust gases is prevented from entering the earth formation but is used to preheat the fuel and oxidant and water. The combustion process is isolated from the steam generation process. (DLC)

  12. Contribution of 222Rn in domestic water supplies to 222Rn in indoor air in Colorado homes

    USGS Publications Warehouse

    Lawrence, E.P.; Wanty, R.B.; Nyberg, P.

    1992-01-01

    The contribution of 222Rn from domestic water wells to indoor air was investigated in a study of 28 houses near Conifer, CO. Air concentrations determined by alpha-track detectors (ATDs) and continuous radon monitors were compared with the predictions of a single-cell model. In many of the houses, the water supply was shown to contribute significantly to levels of indoor 222Rn. The data from the ATD study were augmented with a continuous monitoring study of a house near Lyons, CO. The well water in that house has the highest known concentration of 222Rn in water yet reported (93 MBq m-3). The temporal pattern in the indoor 222Rn concentration corresponds to water-use records. In general, it is difficult to quantify the proportion of indoor radon attributable to water use. Several lines of evidence suggest that the single-cell model underestimates this proportion. Continuous- monitoring data, although useful, are impractical due to the cost of the equipment. We propose a protocol for 222Rn measurement based on three simultaneous integrating radon detectors that may help estimate the proportion of indoor 222Rn derived from the water supply.

  13. Interaction of air temperature and nitrogen supply on root growth and nitrogen uptake by corn

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Nutrient uptake rates by plants are governed by both plant processes and soil properties. Simulation models of nitrogen uptake should account for both demand and availability of nitrogen. The goal of this study was to quantify root growth and nitrogen uptake by corn plants (maize) as affected by air...

  14. Investigation of the tone-burst tube for duct lining attenuation measurement

    NASA Technical Reports Server (NTRS)

    Soffel, A. R.; Morrow, P. F.

    1972-01-01

    The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.

  15. HVAC pipe/duct sizing using artificial neural networks

    SciTech Connect

    Yeh, S.J.D.; Wong, K.F.V.

    1995-12-31

    The main objective of this study is to demonstrate that artificial neural networks (ANN`s) serve as useful aids to Heating, Ventilating and Air-Conditioning (HVAC) system design. In the present work, the design process for sizing fluid systems in HVAC is simulated by using ANN`S. Four ANN`s have been constructed in a personal computer, one for air duct sizing and three for pipe sizing. The air duct network was trained to output the friction rate and duct size. The three pipe sizing neural networks product pressure drops and pipe diameters. By using the trained artificial neural networks, data can be obtained instantly with errors less than 3%. Thus, ANN`s have been shown to simplify traditional methods and procedures in HVAC pipe and air duct sizing.

  16. Primary zone air proportioner

    DOEpatents

    Cleary, Edward N. G.

    1982-10-12

    An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

  17. Better Duct Systems for Home Heating and Cooling

    SciTech Connect

    Not Available

    2004-11-01

    Duct systems used in forced-air space-conditioning systems are a vital element in home energy efficiency. How well a system works makes a big difference in the cost and the effectiveness of heating and cooling a home. At the same time, a duct system that is poorly designed or maintained can have a detrimental effect on the health of the people who live in the house, through the unintended distribution of indoor air pollution.

  18. Salivary duct stones

    MedlinePlus

    ... glands. Salivary duct stones are a type of salivary gland disorder. ... 83. Jackson NM, Mitchell JL, Walvekar RR. Inflammatory disorders of the salivary glands. In: Flint PW, Haughey BH, Lund LJ, et ...

  19. Determination of the evaporation duct height from standard meteorological data

    NASA Astrophysics Data System (ADS)

    Ivanov, V. K.; Shalyapin, V. N.; Levadnyi, Yu. V.

    2007-02-01

    Four models used for evaluating the height of the evaporation duct from measured atmospheric pressure, water and air temperatures, and air humidity are considered.The calculated results are compared with the duct heights measured during two oceanographic expeditions in the tropical zone of the Atlantic Ocean and the equatorial zone of the Indian Ocean. The sensitivity of models to the errors in the meteorological parameters is investigated. It is shown that, in the case of unstable stratification, the heights of ducts in the 5 20-m range can be evaluated with an error of about 2.5 m. Recommendations for selection of optimal models are given.

  20. Assessing Aircraft Supply Air to Recommend Compounds for Timely Warning of Contamination

    NASA Astrophysics Data System (ADS)

    Fox, Richard B.

    Taking aircraft out of service for even one day to correct fume-in-cabin events can cost the industry roughly $630 million per year in lost revenue. The quantitative correlation study investigated quantitative relationships between measured concentrations of contaminants in bleed air and probability of odor detectability. Data were collected from 94 aircraft engine and auxiliary power unit (APU) bleed air tests from an archival data set between 1997 and 2011, and no relationships were found. Pearson correlation was followed by regression analysis for individual contaminants. Significant relationships of concentrations of compounds in bleed air to probability of odor detectability were found (p<0.05), as well as between compound concentration and probability of sensory irritancy detectability. Study results may be useful to establish early warning levels. Predictive trend monitoring, a method to identify potential pending failure modes within a mechanical system, may influence scheduled down-time for maintenance as a planned event, rather than repair after a mechanical failure and thereby reduce operational costs associated with odor-in-cabin events. Twenty compounds (independent variables) were found statistically significant as related to probability of odor detectability (dependent variable 1). Seventeen compounds (independent variables) were found statistically significant as related to probability of sensory irritancy detectability (dependent variable 2). Additional research was recommended to further investigate relationships between concentrations of contaminants and probability of odor detectability or probability of sensory irritancy detectability for all turbine oil brands. Further research on implementation of predictive trend monitoring may be warranted to demonstrate how the monitoring process might be applied to in-flight application.

  1. Film condensation in a horizontal rectangular duct

    NASA Technical Reports Server (NTRS)

    Lu, Qing; Suryanarayana, N. V.

    1993-01-01

    Condensation heat transfer in a horizontal rectangular duct was experimentally and analytically investigated. To prevent the dripping of condensate on the film, the experiment was conducted inside a horizontal rectangular duct with vapor condensing only on the bottom cooled plate of the duct. R-113 and FC-72 (Fluorinert Electronic Fluid developed by the 3M Company) were used as the condensing fluids. The experimental program included measurements of film thickness, local and average heat transfer coefficients, wave length, wave speed, and a study of wave initiation. The measured film thickness was used to obtain the local heat transfer coefficient. The wave initiation was studied both with condensation and with an adiabatic air-liquid flow. The test sections used in both experiments were identical.

  2. Environmental Technology Verification: Supplement to Test/QA Plan for Biological and Aerosol Testing of General Ventilation Air Cleaners; Bioaerosol Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Air Cleaners

    EPA Science Inventory

    The Air Pollution Control Technology Verification Center has selected general ventilation air cleaners as a technology area. The Generic Verification Protocol for Biological and Aerosol Testing of General Ventilation Air Cleaners is on the Environmental Technology Verification we...

  3. Hypothetical air ingress scenarios in advanced modular high temperature gas cooled reactors

    SciTech Connect

    Kroeger, P.G.

    1988-01-01

    Considering an extremely hypothetical scenario of complete cross duct failure and unlimited air supply into the reactor vessel of a modular high temperature gas cooled ractor, it is found that the potential air inflow remains limited due to the high friction pressure drop through the active core. All incoming air will be oxidized to CO and some local external burning would be temporarily possible in such a scenario. The accident would have to continue with unlimited air supply for hundreds of hours before the core structural integrity would be jeopardized.

  4. Sampling size in the verification of manufactured-supplied air kerma strengths

    SciTech Connect

    Ramos, Luis Isaac; Martinez Monge, Rafael

    2005-11-15

    Quality control mandate that the air kerma strengths (S{sub K}) of permanent seeds be verified, this is usually done by statistics inferred from 10% of the seeds. The goal of this paper is to proposed a new sampling method in which the number of seeds to be measured will be set beforehand according to an a priori statistical level of uncertainty. The results are based on the assumption that the S{sub K} has a normal distribution. To demonstrate this, the S{sub K} of each of the seeds measured was corrected to ensure that the average S{sub K} of its sample remained the same. In this process 2030 results were collected and analyzed using a normal plot. In our opinion, the number of seeds sampled should be determined beforehand according to an a priori level of statistical uncertainty.

  5. Transition duct with late injection in turbine system

    SciTech Connect

    LeBegue, Jeffrey Scott; Pentecost, Ronnie Ray; Flanagan, James Scott; Kim, Won -Wook; McMahan, Kevin Weston

    2015-09-15

    A system for supplying an injection fluid to a combustor is disclosed. The system includes a transition duct comprising an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The passage defines a combustion chamber. The system further includes a tube providing fluid communication for the injection fluid to flow through the transition duct and into the combustion chamber.

  6. Patent arterial duct

    PubMed Central

    Forsey, Jonathan T; Elmasry, Ola A; Martin, Robin P

    2009-01-01

    Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area) is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes). Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of pulmonary overcirculation

  7. Patent arterial duct.

    PubMed

    Forsey, Jonathan T; Elmasry, Ola A; Martin, Robin P

    2009-01-01

    Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area) is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes). Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of pulmonary overcirculation

  8. Technology Solutions Case Study: Overcoming Comfort Issues Due to Reduced Flow Room Air Mixing

    SciTech Connect

    2015-03-01

    Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. In this project, IBACOS studied when HVAC equipment is downsized and ducts are unaltered to determine conditions that could cause a supply air delivery problem and to evaluate the feasibility of modifying the duct systems using minimally invasive strategies to improve air distribution.

  9. Converting dual-duct constant-volume systems to variable-volume systems without retrofitting the terminal boxes

    SciTech Connect

    Liu, M.; Claridge, D.E.

    1999-07-01

    Dual-duct constant-air-volume systems can be converted to variable-air-volume systems by installing hot air dampers in the main hot air ducts. No terminal box retrofit is needed. The detailed retrofit procedures and control sequences are described in this paper. Results from a case study building are also presented.

  10. The effects of powered air supply to the respiratory protective device on respiration parameters during rest and exercise.

    PubMed

    Arad, M; Heruti, R; Shaham, E; Atsmon, J; Epstein, Y

    1992-12-01

    The common chemical warfare protective masks impose an excessive respiratory load on the wearer due to elevated breathing resistance and increased dead space. For patients with severe respiratory disease, the excessive respiratory effort may be intolerable. Besides, the substantial negative pressure created within the mask during inspiration may result in an inward leakage in individuals having difficulties with proper facial fitting of the mask. The purpose of the current investigation was to evaluate the effects of a blower, actively driving air, through the mask's filter, at a flow (mean +/- SD) of 42 +/- 2 L/min, on respiratory parameters during rest and moderate exercise. Ten healthy subjects of either sex participated in two experimental sessions, wearing the mask with and without the blower. Each session included 6 min of sitting at rest and 6 min of walking on a treadmill (3.2 mph, and 10 percent grade). In nine of the subjects, the active air supply produced a positive inspiratory pressure at rest (5 +/- 4 vs -24 +/- 9 mm H2O peak inspiratory pressure with and without the blower, respectively, p < 0.0001). Inspiratory carbon dioxide concentration (FICO2) at rest was diminished (0.4 +/- 0.4 vs 1.3 +/- 0.7 percent with and without the blower, respectively; p < 0.01) while FIO2 increased from 19.5 +/- 0.7 percent to 20.6 +/- 0.4 percent with the device (p < 0.01). These changes were associated with a significant decrease in respiratory rate (15 +/- 2 vs 18 +/- 3 per minute, p < 0.01). During exercise the blower barely decreased the negative inspiratory pressures, had no effect on other respiratory parameters measured, but significantly shortened the inspiratory/cycle-length time ratio (0.46 +/- 0.03 vs 0.53 +/- 0.03, p < 0.005). The effects of active air supply were not different between male and female subjects. We conclude that the blower is expected to be a useful accessory to respiratory protective devices for patients with pulmonary disease. PMID:1446491

  11. Detonation duct gas generator demonstration program

    NASA Technical Reports Server (NTRS)

    Wortman, Andrew; Brinlee, Gayl A.; Othmer, Peter; Whelan, Michael A.

    1991-01-01

    The feasibility of the generation of detonation waves moving periodically across high speed channel flow is experimentally demonstrated. Such waves are essential to the concept of compressing requirements and increasing the engine pressure compressor with the objective of reducing conventional compressor requirements and increasing the engine thermodynamic efficiency through isochoric energy addition. By generating transient transverse waves, rather than standing waves, shock wave losses are reduced by an order of magnitude. The ultimate objective is to use such detonation ducts downstream of a low pressure gas turbine compressor to produce a high overall pressure ratio thermodynamic cycle. A 4 foot long, 1 inch x 12 inch cross-section, detonation duct was operated in a blow-down mode using compressed air reservoirs. Liquid or vapor propane was injected through injectors or solenoid valves located in the plenum or the duct itself. Detonation waves were generated when the mixture was ignited by a row of spark plugs in the duct wall. Problems with fuel injection and mixing limited the air speeds to about Mach 0.5, frequencies to below 10 Hz, and measured pressure ratios of about 5 to 6. The feasibility of the gas dynamic compression was demonstrated and the critical problem areas were identified.

  12. Research on the water hammer protection of the long distance water supply project with the combined action of the air vessel and over-pressure relief valve

    NASA Astrophysics Data System (ADS)

    Li, D. D.; Jiang, J.; Zhao, Z.; Yi, W. S.; Lan, G.

    2013-12-01

    We take a concrete pumping station as an example in this paper. Through the calculation of water hammer protection with a specific pumping station water supply project, and the analysis of the principle, mathematical models and boundary conditions of air vessel and over-pressure relief valve we show that the air vessel can protect the water conveyance system and reduce the transient pressure damage due to various causes. Over-pressure relief valve can effectively reduce the water hammer because the water column re-bridge suddenly stops the pump and prevents pipeline burst. The paper indicates that the combination set of air vessel and over-pressure relief valve can greatly reduce the quantity of the air valve and can eliminate the water hammer phenomenon in the pipeline system due to the vaporization and water column separation and re-bridge. The conclusion could provide a reference for the water hammer protection of long-distance water supply system.

  13. Turbofan Duct Propagation Model

    NASA Technical Reports Server (NTRS)

    Lan, Justin H.; Posey, Joe W. (Technical Monitor)

    2001-01-01

    The CDUCT code utilizes a parabolic approximation to the convected Helmholtz equation in order to efficiently model acoustic propagation in acoustically treated, complex shaped ducts. The parabolic approximation solves one-way wave propagation with a marching method which neglects backwards reflected waves. The derivation of the parabolic approximation is presented. Several code validation cases are given. An acoustic lining design process for an example aft fan duct is discussed. It is noted that the method can efficiently model realistic three-dimension effects, acoustic lining, and flow within the computational capabilities of a typical computer workstation.

  14. Air

    MedlinePlus

    ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be polluted indoors and it can ... this chart to see what things cause indoor air pollution and what things cause outdoor air pollution! Indoor ...

  15. Gas turbine engine and its associated air intake system

    SciTech Connect

    Ballard, J.R.; Bennett, G.H.; Lee, L.A.

    1984-01-17

    A gas turbine engine and its associated air intake system are disclosed in which the air intake system comprises a generally horizontally extending duct through which an airflow is induced by an ejector pump powered by the engine. A portion of the air passing through the duct is directed through a second duct to the air inlet of the engine. The second duct is connected to the first duct in such a manner that the air directed to the engine air inlet is derived from a vertically upper region of the first duct. The arrangement is intended to reduce the amount of airborne particulate material ingested by the gas turbine engine.

  16. Seasonal variations of surface duct conditions in Ngaoundere, North Cameroon

    NASA Astrophysics Data System (ADS)

    Kaissassou, Samuel; Lenouo, André; Nzeukou, Armand; Tchawoua, Clément; Vondou, D. A.

    2015-12-01

    The seasonal variations of refractivity gradients from 104 to 3000 m above ground level in the troposphere layer are presented based on observations from the radiosonde station located in Ngaoundere (13.5°E, 7.3°N), a middle belt savannah region of Cameroon. Six years (2006-2011) of data from in situ measurements made by Agency for the Safety of Air Navigation in Africa and Madagascar (ASECNA) of the temperature, moisture, and pressure are used to determine the surface duct conditions over Ngaoundere region. Each time that a negative gradient from the Abel-retrieved refractivity profiles is seen, it implies the presence of a duct in this study. The occurrence of ducts strongly depends on the local climate and synoptic weather conditions which have an appreciable influence on the refractivity vertical profile, especially the seasonal north-south movement of the Inter Tropical Convergence Zone (ITCZ) which provides wet and dry seasons to the region. Monthly and seasonal variations of ducts were also determined from the measured data. The highest and the lowest occurrence rate of surface ducts were observed during the wet and the dry seasons, respectively. September appears as the month when most of the ducts occur at the rate of at least one duct per day. The median duct thickness and duct strength are high and strong during the wet season, whereas they are low and weak during the dry season. When the data are separated into stable and unstable atmospheric conditions, we noticed that surface duct characteristics show some seasonal differences. Surface ducts are found to be more frequent in a stable atmosphere than in an unstable atmosphere. Statistical results are discussed alongside with local meteorological conditions and weather systems affecting the town of Ngaoundere. Besides, comments are made on their prospective significance in the region.

  17. What Is Bile Duct Cancer?

    MedlinePlus

    ... of bile duct cancer. The rest of this document refers only to cholangiocarcinomas. Benign bile duct tumors ... tumors, which aren’t discussed further in this document. Other cancers in the liver The most common ...

  18. Dynamic instability of ducts conveying fluid

    NASA Technical Reports Server (NTRS)

    Yu, Y. Y.

    1975-01-01

    A finite element analysis was used to study dynamic instability in ducts conveying high speed fluids. Ducts examined include cantilevered curved, flexibly supported, arbitrarily shaped, and composite duct systems. Partial differential equations were used to study the duct systems.

  19. Sound attenuation of fiberglass lined ventilation ducts

    NASA Astrophysics Data System (ADS)

    Albright, Jacob

    Sound attenuation is a crucial part of designing any HVAC system. Most ventilation systems are designed to be in areas occupied by one or more persons. If these systems do not adequately attenuate the sound of the supply fan, compressor, or any other source of sound, the affected area could be subject to an array of problems ranging from an annoying hum to a deafening howl. The goals of this project are to quantify the sound attenuation properties of fiberglass duct liner and to perform a regression analysis to develop equations to predict insertion loss values for both rectangular and round duct liners. The first goal was accomplished via insertion loss testing. The tests performed conformed to the ASTM E477 standard. Using the insertion loss test data, regression equations were developed to predict insertion loss values for rectangular ducts ranging in size from 12-in x 18-in to 48-in x 48-in in lengths ranging from 3ft to 30ft. Regression equations were also developed to predict insertion loss values for round ducts ranging in diameters from 12-in to 48-in in lengths ranging from 3ft to 30ft.

  20. 42 CFR 84.163 - Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements. 84.163 Section 84.163 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  1. 42 CFR 84.163 - Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements. 84.163 Section 84.163 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  2. 42 CFR 84.163 - Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements. 84.163 Section 84.163 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  3. 42 CFR 84.162 - Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  4. 42 CFR 84.163 - Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements. 84.163 Section 84.163 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  5. 42 CFR 84.162 - Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  6. 42 CFR 84.162 - Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  7. 42 CFR 84.162 - Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  8. 42 CFR 84.163 - Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements. 84.163 Section 84.163 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  9. 42 CFR 84.162 - Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  10. Duct Leakage Repeatability Testing

    SciTech Connect

    Walker, Iain; Sherman, Max

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

  11. EFFECT OF AIRFLOW AND HEAT INPUT RATES ON DUCT EFFICIENCY.

    SciTech Connect

    ANDREWS,J.W.

    2003-05-28

    Reducing the airflow and heat input rates of a furnace that is connected to a duct system in thermal contact with unconditioned spaces can significantly reduce thermal distribution efficiency. This is a straightforward theoretical calculation based on the increased residence time of the air in the duct at the lower flow rate, which results in greater conduction losses. Experimental tests in an instrumented residential-size duct system have confirmed this prediction. Results are compared with the heat-loss algorithm in ASHRAE Standid 152P. The paper concludes with a discussion of possible remedies for this loss of efficiency in existing systems and optional design strategies in new construction.

  12. Heat Transfer in a Superelliptic Transition Duct

    NASA Technical Reports Server (NTRS)

    Poinsatte, Philip; Thurman, Douglas; Hippensteele, Steven

    2008-01-01

    Local heat transfer measurements were experimentally mapped using a transient liquid-crystal heat transfer technique on the surface of a circular-to-rectangular transition duct. The transition duct had a length-to-diameter ratio of 1.5 and an exit-plane aspect ratio of 3. The crosssectional geometry was defined by the equation of a superellipse. The cross-sectional area was the same at the inlet and exit but varied up to 15 percent higher through the transition. The duct was preheated to a uniform temperature (nominally 64 C) before allowing room temperature air to be suddenly drawn through it. As the surface cooled, the resulting isothermal contours on the duct surface were revealed using a surface coating of thermochromic liquid crystals that display distinctive colors at particular temperatures. A video record was made of the surface temperature and time data for all points on the duct surfaces during each test. Using this surface temperature-time data together with the temperature of the air flowing through the model and the initial temperature of the model wall, the heat transfer coefficient was calculated by employing the classic one-dimensional, semi-infinite wall heat transfer conduction model. Test results are reported for inlet diameter-based Reynolds numbers ranging from 0.4x106 to 2.4x106 and two grid-generated freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

  13. Compact Buried Ducts in a Hot-Humid Climate House

    SciTech Connect

    Mallay, D.

    2016-01-01

    A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval.

  14. Efficiency of shock wave attenuation in ducts by various methods

    NASA Astrophysics Data System (ADS)

    Frolov, S. M.

    1993-02-01

    Different methods of shock wave attenuation in ducts are compared in terms of efficiency. The methods investigated include expansion of the duct cross section, the use of perforated side walls, and the use of porous screens and screen cascades. The attentuation of air shock waves is estimated by using a unified approach which provides satisfactory agreement with experimental data. Based on the results of the study, a nomogram is plotted which can be used for practical calculations.

  15. Measure Guideline: Summary of Interior Ducts in New Construction, Including an Efficient, Affordable Method to Install Fur-Down Interior Ducts

    SciTech Connect

    Beal, D.; McIlvaine , J.; Fonorow, K.; Martin, E.

    2011-11-01

    This document illustrates guidelines for the efficient installation of interior duct systems in new housing, including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. This document illustrates guidelines for the efficient installation of interior duct systems in new housing. Interior ducts result from bringing the duct work inside a home's thermal and air barrier. Architects, designers, builders, and new home buyers should thoroughly investigate any opportunity for energy savings that is as easy to implement during construction, such as the opportunity to construct interior duct work. In addition to enhanced energy efficiency, interior ductwork results in other important advantages, such as improved indoor air quality, increased system durability and increased homeowner comfort. While the advantages of well-designed and constructed interior duct systems are recognized, the implementation of this approach has not gained a significant market acceptance. This guideline describes a variety of methods to create interior ducts including the fur-up chase method, the fur-down chase method, and interior ducts positioned in sealed attics or sealed crawl spaces. As communication of the intent of an interior duct system, and collaboration on its construction are paramount to success, this guideline details the critical design, planning, construction, inspection, and verification steps that must be taken. Involved in this process are individuals from the design team; sales/marketing team; and mechanical, insulation, plumbing, electrical, framing, drywall and solar contractors.

  16. Effect of room air recirculation delay on the decay rate of tracer gas concentration

    SciTech Connect

    Kristoffersen, A.R.; Gadgil, A.J.; Lorenzetti, D.M.

    2004-05-01

    Tracer gas measurements are commonly used to estimate the fresh air exchange rate in a room or building. Published tracer decay methods account for fresh air supply, infiltration, and leaks in ductwork. However, the time delay associated with a ventilation system recirculating tracer back to the room also affects the decay rate. We present an analytical study of tracer gas decay in a well-mixed, mechanically-ventilated room with recirculation. The analysis shows that failing to account for delays can lead to under- or over-estimates of the fresh air supply, depending on whether the decay rate calculation includes the duct volume.

  17. 29. DETAIL OF OUTLET DUCTS FOR MST AIRCONDITIONING SYSTEM IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. DETAIL OF OUTLET DUCTS FOR MST AIR-CONDITIONING SYSTEM IN NORTHWEST CORNER OF SLC-3W MST STATION 70.5 (LOWEST PAYLOAD SERVICE STATION). NOTE RING ATTACHMENT FOR PERSONNEL SAFETY HARNESS IN LEFT FOREGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. The flow field of an underexpanded H2 jet coaxially injected into a hot free or ducted supersonic jet of air or nitrogen

    NASA Technical Reports Server (NTRS)

    Jenkins, R. V.

    1977-01-01

    Experimental data obtained in an investigation of the mixing of an underexpanded hydrogen jet in a supersonic flow both with and without combustion are presented. Tests were conducted in a Mach 2 test stream with both air and nitrogen as test media. Total temperature of the test stream was 2170 K, and static exit pressure was about one atmosphere. The static pressure at the exit of the hydrogen injector's Mach 2 nozzle was about two atmospheres. Primary measurements included shadowgraphs and pitot pressure surveys of the flow field. Pitot surveys and wall static pressures were measured for the case where the entire flow was shrouded. The results are compared to similar experimental data and theoretical predictions for the matched pressure case.

  19. Complicated bile duct stones.

    PubMed

    Roy, Ashwin; Martin, Derrick

    2013-01-01

    Common bile duct stones (CBDSs) are solid deposits that can either form within the gallbladder or migrate to the common bile duct (CBD), or form de novo in the biliary tree. In the USA around 15% of the population have gallstones and of these, 3% present with symptoms annually. Because of this, there have been major advancements in the management of gallstones and related conditions. Management is based on the patient's risk profile; young and healthy patients are likely to be recommended for surgery and elderly patients with comorbidities are usually recommended for endoscopic procedures. Imaging of gallstones has advanced in the last 30 years with endoscopic retrograde cholangiopancreatography evolving from a diagnostic to a therapeutic procedure in removing CBDSs. We present a complicated case of a patient with a CBDS and periampullary diverticulum and discuss the techniques used to diagnose and remove the stone from the biliary system. PMID:23946532

  20. Complicated bile duct stones

    PubMed Central

    Roy, Ashwin; Martin, Derrick

    2013-01-01

    Common bile duct stones (CBDSs) are solid deposits that can either form within the gallbladder or migrate to the common bile duct (CBD), or form de novo in the biliary tree. In the USA around 15% of the population have gallstones and of these, 3% present with symptoms annually. Because of this, there have been major advancements in the management of gallstones and related conditions. Management is based on the patient's risk profile; young and healthy patients are likely to be recommended for surgery and elderly patients with comorbidities are usually recommended for endoscopic procedures. Imaging of gallstones has advanced in the last 30 years with endoscopic retrograde cholangiopancreatography evolving from a diagnostic to a therapeutic procedure in removing CBDSs. We present a complicated case of a patient with a CBDS and periampullary diverticulum and discuss the techniques used to diagnose and remove the stone from the biliary system. PMID:23946532

  1. Lacrimal duct cyst abscess.

    PubMed

    Dharmasena, Aruna; Sobajo, Cassandra; Irion, Luciane; Ataullah, Sajid

    2014-12-01

    Cystic dilatation within the lacrimal gland is thought to be related to chronic inflammation and scarring of the lacrimal gland ductules. We review the literature and discuss a case and of lacrimal duct cyst suppuration presenting with visual loss, external ophthalmoplegia, proptosis and ptosis. To our knowledge, only one other report of a lacrimal ductal cyst abscess has been reported in the literature so far. PMID:25208223

  2. Optimizing Electrospray Interfaces Using Slowly Diverging Conical Duct (ConDuct) Electrodes

    PubMed Central

    Krutchinsky, Andrew N.; Padovan, Júlio C.; Cohen, Herbert; Chait, Brian T.

    2015-01-01

    We demonstrate that the efficiency of ion transmission from atmosphere to vacuum through stainless steel electrodes that contain slowly divergent conical duct (ConDuct) channels can be close to 100%. Here, we explore the properties of 2.5 cm long electrodes with angles of divergence of 0°, 1°, 2°, 3°, 5°, 8°, 13°, and 21°, respectively. The ion transmission efficiency was observed to jump from 10–20% for the 0° (straight) channels to 90–95% for channels with an angle of divergence as small as 1°. Furthermore, the 2–3° ConDuct electrodes produced extraordinarily low divergence ion beams that propagated in a laser-like fashion over long distances in vacuum. To take advantage of these newly discovered properties, we constructed a novel atmosphere-to-vacuum ion interface utilizing a 2° ConDuct as an inlet electrode and compared its ion transmission efficiency with that of the interface used in the commercial (Thermo) Velos Orbitrap and Q Exactive mass spectrometers. We observed that the ConDuct interface transmitted up to 17 times more ions than the commercial reference interface and also yielded improved signal-to-noise mass spectra of peptides. We infer from these results that the performance of many current atmosphere-tovacuum interfaces utilizing metal capillaries can be substantially improved by replacing them with 1° or 2° metal ConDuct electrodes, which should preserve the convenience of supplying ion desolvation energy by heating the electrode while greatly increasing the efficiency of ion transmission into the mass spectrometer. PMID:25667060

  3. Duct Leakage Modeling in EnergyPlus and Analysis of Energy Savings from Implementing SAV with InCITeTM

    SciTech Connect

    Wray, Craig; Sherman, Max

    2010-03-01

    This project addressed two significant deficiencies in air-handling systems for large commercial building: duct leakage and duct static pressure reset. Both constitute significant energy reduction opportunities for these buildings. The overall project goal is to bridge the gaps in current duct performance modeling capabilities, and to expand our understanding of air-handling system performance in California large commercial buildings. The purpose of this project is to provide technical support for the implementation of a duct leakage modeling capability in EnergyPlus, to demonstrate the capabilities of the new model, and to carry out analyses of field measurements intended to demonstrate the energy saving potential of the SAV with InCITeTM duct static pressure reset (SPR) technology. A new duct leakage model has been successfully implemented in EnergyPlus, which will enable simulation users to assess the impacts of leakage on whole-building energy use and operation in a coupled manner. This feature also provides a foundation to support code change proposals and compliance analyses related to Title 24 where duct leakage is an issue. Our example simulations continue to show that leaky ducts substantially increase fan power: 10percent upstream and 10percent downstream leakage increases supply fan power 30percent on average compared to a tight duct system (2.5percent upstream and 2.5percent downstream leakage). Much of this increase is related to the upstream leakage rather than to the downstream leakage. This does not mean, however, that downstream leakage is unimportant. Our simulations also demonstrate that ceiling heat transfer is a significant effect that needs to be included when assessing the impacts of duct leakage in large commercial buildings. This is not particularly surprising, given that ?ceiling regain? issues have already been included in residential analyses as long as a decade ago (e.g., ASHRAE Standard 152); mainstream simulation programs that are

  4. Penumatic-power supply

    NASA Technical Reports Server (NTRS)

    Kramer, R. C.

    1981-01-01

    Portable compressed air supply has two or more outputs at pressures from 20 to 100 psi. Applications include operating production equipment, spraying paint and lubricants, and pressurizing refrigeration systems. Supply filters air from standard high-pressure line, reduces it to working pressure, and adds lubricant when required. Regulator supplies low-pressure air to output channels. On channel lines, vernier-control valves select output pressures.

  5. Method and apparatus for determining the proportions of the constituents of the air-fuel mixture supplied to an internal combustion engine

    SciTech Connect

    Peter, C.

    1980-11-04

    A method and apparatus are described for determining the proportions of the air-fuel mixture constituents supplied to an internal combustion engine from a mixture preparing device such as a carburator, a fuel injection device or other suitable mixture preparing device. The method according to the invention serves to simplify the processing of output signals that are supplied to a mixture preparing device having at least two lambda sensors. The invention is especially suitable for use with large engines with several exhaust conduit systems, such as so-called v-engines, in which generally there is an unequal mixture distribution between the two rows of cylinders. By employing at least two lambda sensors in the exhaust gas conduit system for monitoring the exhaust gas composition, one succeeds in determining the mixture composition of the air-fuel mixture applied to all cylinders, and in influencing the air-fuel mixture in a suitable supplementary manner by a feed back of the actual value signals generated by the lambda sensors to the fuel preparation device, so that a desirable overall exhaust gas average value can be achieved. The apparatus employs two integrators and suitable logic circuitry for applying the lambda sensor signals to the integrators in such a manner that one integrator regulates the entire mixture in the desired direction, according to the sensor signals supplied to it, while the other integrator sets the amplitude of the oscillation fluctuations at a value that corresponds to the lambda differential.

  6. Bile duct malignancies.

    PubMed

    Tucek, S; Tomasek, J; Halámkova, J; Kiss, I; Andrasina, T; Hemmelová, B; Adámková-Krákorová, D; Vyzula, R

    2010-01-01

    Bile duct malignancies include intrahepatic cholangiocarcinoma (ICC), extrahepatic cholangiocarcinoma (ECC), gall bladder carcinoma (GC) and carcinoma of Vater's ampulla (ampulloma). Bile duct neoplasms are rare tumours with overall poor prognosis. The overall incidence affects up to 12.5 per 100,000 persons in the Czech Republic. The mortality rate has risen recently to 9.5 per 100,000 persons. The incidence and mortality have been remarkably stable over the past 3 decades. The survival rate of patients with these tumours is poor, usually not exceeding 12 months. The diagnostic process is complex, uneasy and usually late. Most cases are diagnosed when unresectable, and palliative treatment is the main approach of medical care for these tumours. The treatment remains very challenging. New approaches have not brought much improvement in this field. Standards of palliative care are lacking and quality of life assessments are surprisingly not common. From the scarce data it seems, however, that multimodal individually tailored treatment can prolong patients'survival and improve the health-related quality of life. The care in specialized centres offers methods of surgery, interventional radiology, clinical oncology and high quality supportive care. These methods are discussed in the article in greater detail. Improvements in this field can be sought in new diagnostic methods and new procedures in surgery and interventional radiology. Understanding the tumour biology on the molecular level could shift the strategy to a more successful one, resulting in more cured patients. Further improvements in palliative care can be sought by defining new targets and new drug development. The lack of patients with bile duct neoplasms has been the limiting factor for any improvements. A new design of larger randomized international multicentric clinical trials with prompt data sharing could help to overcome this major problem. Defining standards of palliative care is a necessity

  7. Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes

    SciTech Connect

    Beach, R.; Burdick, A.

    2014-03-01

    This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance (Rutkowski, H. Manual D -- Residential Duct Systems, 3rd edition, Version 1.00. Arlington, VA: Air Conditioning Contractors of America, 2009.). IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations (Beach, R., Prahl, D., and Lange, R. CFD Analysis of Flexible Duct Junction Box Design. Golden, CO: National Renewable Energy Laboratory, submitted for publication 2013). These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.

  8. Subsonic Flows through S-Ducts with Flow Control

    NASA Astrophysics Data System (ADS)

    Chen, Yi

    An inlet duct of an aircraft connects the air intake mounted on the fuselage to the engine within the aircraft body. The ideal outflow quality of the duct is steady, uniform and of high total pressure. Recently compact S-shaped inlet ducts are drawing more attention in the design of UAVs with short propulsion system. Compact ducts usually involve strong streamwise adverse pressure gradient and transverse secondary flow, leading to large-scale harmful vortical structures in the outflow. To improve the outflow quality modern flow control techniques have to be applied. Before designing successful flow control methods a solid understanding of the baseline flow field with the duct is crucial. In this work the fundamental mechanism of how the three dimensional flow topology evolves when the relevant parameters such as the duct geometry and boundary layer thickness are varied, is studied carefully. Two distinct secondary-flow patterns are identified. For the first time the sensitivity of the flow topology to the inflow boundary layer thickness in long ducts is clearly addressed. The interaction between the transverse motion induced by the transverse pressure gradient and the streamwise separation is revealed as the crucial reason for the various flow patterns existing in short ducts. A non-symmetric flow pattern is identified for the first time in both experiments and simulations in short ducts in which the intensity of the streamwise separation and the transverse invasion are in the same order of magnitude. A theory of energy accumulation and solution bifurcation is used to give a reasonable explanation for this non-symmetry. After gaining the knowledge of where and how the harmful vortical structures are generated several flow control techniques are tested to achieve a better outflow quality. The analysis of the flow control cases also provides a deeper insight into the behavior of the three-dimensional flow within the ducts. The conventional separation control method

  9. Intrahepatic Transposition of Bile Ducts

    PubMed Central

    Delić, Jasmin; Savković, Admedina; Isaković, Eldar; Marković, Sergije; Bajtarevic, Alma; Denjalić, Amir

    2012-01-01

    Objective. To describe the intrahepatic bile duct transposition (anatomical variation occurring in intrahepatic ducts) and to determine the frequency of this variation. Material and Methods. The researches were performed randomly on 100 livers of adults, both sexes. Main research methods were anatomical macrodissection. As a criterion for determination of variations in some parts of bile tree, we used the classification of Segmentatio hepatis according to Couinaud (1957) according to Terminologia Anatomica, Thieme Stuugart: Federative Committee on Anatomical Terminology, 1988. Results. Intrahepatic transposition of bile ducts was found in two cases (2%), out of total examined cases (100): right-left transposition (right segmental bile duct, originating from the segment VIII, joins the left liver duct-ductus hepaticus sinister) and left-right intrahepatic transposition (left segmental bile duct originating from the segment IV ends in right liver duct-ductus hepaticus dexter). Conclusion. Safety and success in liver transplantation to great extent depends on knowledge of anatomy and some common embryological anomalies in bile tree. Variations in bile tree were found in 24–43% of cases, out of which 1–22% are the variations of intrahepatic bile ducts. Therefore, good knowledge on ductal anatomy enables good planning, safe performance of therapeutic and operative procedures, and decreases the risk of intraoperative and postoperative complications. PMID:22550601

  10. Vortex Shedding Inside a Baffled Air Duct

    NASA Technical Reports Server (NTRS)

    Davis, Philip; Kenny, R. Jeremy

    2010-01-01

    Common in the operation of both segmented and un-segmented large solid rocket motors is the occurrence of vortex shedding within the motor chamber. A portion of the energy within a shed vortex is converted to acoustic energy, potentially driving the longitudinal acoustic modes of the motor in a quasi-discrete fashion. This vortex shedding-acoustic mode excitation event occurs for every Reusable Solid Rocket Motor (RSRM) operation, giving rise to subsequent axial thrust oscillations. In order to better understand this vortex shedding/acoustic mode excitation phenomena, unsteady CFD simulations were run for both a test geometry and the full scale RSRM geometry. This paper covers the results from the subscale geometry runs, which were based on work focusing on the RSRM hydrodynamics. Unsteady CFD simulation parameters, including boundary conditions and post-processing returns, are reviewed. The results were further post-processed to identify active acoustic modes and vortex shedding characteristics. Probable locations for acoustic energy generation, and subsequent acoustic mode excitation, are discussed.

  11. Ascariasis of the pancreatic duct.

    PubMed

    Klimovskij, Michail; Dulskas, Audrius; Kraulyte, Zita; Mikalauskas, Saulius

    2015-01-01

    Ascariasis is a common helminthic disease worldwide, although Lithuania and other European countries are not considered endemic areas. The presence of the Ascaris worm in the biliary tree causes choledocholithiasis-like symptoms. We report a case of pancreatic duct ascariasis causing such symptoms. A 73-year-old Lithuanian woman underwent endoscopic retrograde cholangiopancreatography (ERCP) suspecting choledocholithiasis. Contrast injection into the common bile duct demonstrated a slightly dilated biliary tree without any filling defects, and the tail of an Ascaris worm protruding from the opening of the papilla Vater. The worm was captured by a snare but escaped deep into the duct. After a small wirsungotomy the worm was retrieved from the pancreatic duct. The patient received a 150 mg dose of levamisole orally repeated 7 days later and was discharged after complete resolution of symptoms. This first reported sporadic case of pancreatic duct ascariasis in Lithuania was successfully treated with ERCP and Levamisole. PMID:26374772

  12. Measure Guideline: Buried and/or Encapsulated Ducts

    SciTech Connect

    Shapiro, C.; Zoeller, W.; Mantha, P.

    2013-08-01

    Buried and/or encapsulated ducts (BEDs) are a class of advanced, energy-efficiency strategies intended to address the significant ductwork thermal losses associated with ducts installed in unconditioned attics. BEDs are ducts installed in unconditioned attics that are covered in loose-fill insulation and/or encapsulated in closed cell polyurethane spray foam insulation. This Measure Guideline covers the technical aspects of BEDs as well as the advantages, disadvantages, and risks of BEDs compared to other alternative strategies. This guideline also provides detailed guidance on installation of BEDs strategies in new and existing homes through step-by-step installation procedures. This Building America Measure Guideline synthesizes previously published research on BEDs and provides practical information to builders, contractors, homeowners, policy analysts, building professions, and building scientists. Some of the procedures presented here, however, require specialized equipment or expertise. In addition, some alterations to duct systems may require a specialized license. Persons implementing duct system improvements should not go beyond their expertise or qualifications. This guideline provides valuable information for a building industry that has struggled to address ductwork thermal losses in new and existing homes. As building codes strengthen requirements for duct air sealing and insulation, flexibility is needed to address energy efficiency goals. While ductwork in conditioned spaces has been promoted as the panacea for addressing ductwork thermal losses, BEDs installations approach - and sometimes exceed - the performance of ductwork in conditioned spaces.

  13. The impact of duct-to-duct interaction on the hex duct dilation

    SciTech Connect

    Lee, M.J.; Chang, L.K.; Lahm, C.E.; Porter, D.L.

    1992-07-01

    Dilation of the hex duct is an important factor in the operational lifetime of fuel subassemblies in liquid metal fast reactors. It is caused primarily by the irradiation-enhanced creep and void swelling of the hex duct material. Excessive dilation may jeopardize subassembly removal from the core or cause a subassembly storage problem where the grid size of the storage basket is limited. Dilation of the hex duct in Experimental Breeder Reactor II (EBR-II) limits useful lifetime because of these storage basket limitations. It is, therefore, important to understand the hex duct dilation behavior to guide the design and in-core management of fuel subassemblies in a way that excessive duct deformation can be avoided. To investigate the dilation phenomena, finite-element models of the hex duct have been developed. The inelastic analyses were performed using the structural analysis code, ANSYS. Both Type 316 and D9 austenitic stainless steel ducts are considered. The calculated dilations are in good agreement with profilometry measurements made after irradiation. The analysis indicates that subassembly interaction is an important parameter in addition to neutron fluence and temperature in determining hex duct dilation. 5 refs.

  14. Observations of Strong Surface Radar Ducts over the Persian Gulf.

    NASA Astrophysics Data System (ADS)

    Brooks, Ian M.; Goroch, Andreas K.; Rogers, David P.

    1999-09-01

    Ducting of microwave radiation is a common phenomenon over the oceans. The height and strength of the duct are controlling factors for radar propagation and must be determined accurately to assess propagation ranges. A surface evaporation duct commonly forms due to the large gradient in specific humidity just above the sea surface; a deeper surface-based or elevated duct frequently is associated with the sudden change in temperature and humidity across the boundary layer inversion.In April 1996 the U.K. Meteorological Office C-130 Hercules research aircraft took part in the U.S. Navy Ship Antisubmarine Warfare Readiness/Effectiveness Measuring exercise (SHAREM-115) in the Persian Gulf by providing meteorological support and making measurements for the study of electromagnetic and electro-optical propagation. The boundary layer structure over the Gulf is influenced strongly by the surrounding desert landmass. Warm dry air flows from the desert over the cooler waters of the Gulf. Heat loss to the surface results in the formation of a stable internal boundary layer. The layer evolves continuously along wind, eventually forming a new marine atmospheric boundary layer. The stable stratification suppresses vertical mixing, trapping moisture within the layer and leading to an increase in refractive index and the formation of a strong boundary layer duct. A surface evaporation duct coexists with the boundary layer duct.In this paper the authors present aircraft- and ship-based observations of both the surface evaporation and boundary layer ducts. A series of sawtooth aircraft profiles map the boundary layer structure and provide spatially distributed estimates of the duct depth. The boundary layer duct is found to have considerable spatial variability in both depth and strength, and to evolve along wind over distances significant to naval operations (100 km). The depth of the evaporation duct is derived from a bulk parameterization based on Monin-Obukhov similarity theory

  15. Building America Case Study: Duct in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida (Fact Sheet)

    SciTech Connect

    Not Available

    2014-09-01

    Forced air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as an attic or crawlspace. Any leakage of air to or from the duct system (duct leakage) in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution to this problem is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (sealed attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raised ceiling or fur-up chase) or below the ceiling plane (dropped ceiling or fur-down) for the duct system. This case study examines one Building America builder partner's implementation of an inexpensive, quick and effective method of building a fur-down or dropped ceiling chase.

  16. High-Performance Ducts in Hot-Dry Climates

    SciTech Connect

    Hoeschele, Marc; Chitwood, Rick; German, Alea; Weitzel, Elizabeth

    2015-07-30

    Duct thermal losses and air leakage have long been recognized as prime culprits in the degradation of heating, ventilating, and air-conditioning (HVAC) system efficiency. Both the U.S. Department of Energy’s Zero Energy Ready Home program and California’s proposed 2016 Title 24 Residential Energy Efficiency Standards require that ducts be installed within conditioned space or that other measures be taken to provide similar improvements in delivery effectiveness (DE). Pacific Gas & Electric Company commissioned a study to evaluate ducts in conditioned space and high-performance attics (HPAs) in support of the proposed codes and standards enhancements included in California’s 2016 Title 24 Residential Energy Efficiency Standards. The goal was to work with a select group of builders to design and install high-performance duct (HPD) systems, such as ducts in conditioned space (DCS), in one or more of their homes and to obtain test data to verify the improvement in DE compared to standard practice. Davis Energy Group (DEG) helped select the builders and led a team that provided information about HPD strategies to them. DEG also observed the construction process, completed testing, and collected cost data.

  17. Report on Recent Upgrades to the Curved Duct Test Rig at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Brown, Martha C.; Jones, Michael G.; Howerton, Brian M.

    2011-01-01

    The Curved Duct Test Rig (CDTR) is an experimental facility that is designed to assess the acoustic and aerodynamic performance of aircraft engine nacelle liners in close to full scale. The test section is between 25% and 100% of the scale of aft bypass ducts of aircraft engines ranging in size from business jet to large commercial passenger jet. The CDTR has been relocated and now shares space with the Grazing Flow Impedance Tube in the Liner Technology Facility at NASA Langley Research Center. As a result of the relocation, research air is supplied to the CDTR from a 50,000 cfm centrifugal fan. This new air supply enables testing of acoustic liner samples at up to Mach 0.500. This paper documents experiments and analysis on a baseline liner sample, which the authors had analyzed and reported on prior to the move to the new facility. In the present paper, the experimental results are compared to those obtained previously in order to ensure continuity of the experimental capability. Experiments that take advantage of the facility s expanded capabilities are also reported. Data analysis features that enhance understanding of the physical properties of liner performance are introduced. The liner attenuation is shown to depend on the mode that is incident on the liner test section. The relevant parameter is the mode cut-on ratio, which determines the angle at which the sound wave is incident on the liner surface. The scattering of energy from the incident mode into higher order, less attenuated modes is demonstrated. The configuration of the acoustic treatment, in this case lined on one surface and hard wall on the opposite surface, is shown to affect the mode energy redistribution.

  18. PMR Graphite Engine Duct Development

    NASA Technical Reports Server (NTRS)

    Stotler, C. L.; Yokel, S. A.

    1989-01-01

    The objective was to demonstrate the cost and weight advantages that could be obtained by utilizing the graphite/PMR15 material system to replace titanium in selected turbofan engine applications. The first component to be selected as a basis for evaluation was the outer bypass duct of the General Electric F404 engine. The operating environment of this duct was defined and then an extensive mechanical and physical property test program was conducted using material made by processing techniques which were also established by this program. Based on these properties, design concepts to fabricate a composite version of the duct were established and two complete ducts fabricated. One of these ducts was proof pressure tested and then run successfully on a factory test engine for over 1900 hours. The second duct was static tested to 210 percent design limit load without failure. An improved design was then developed which utilized integral composite end flanges. A complete duct was fabricated and successfully proof pressure tested. The net results of this effort showed that a composite version of the outer duct would be 14 percent lighter and 30 percent less expensive that the titanium duct. The other type of structure chosen for investigation was the F404 fan stator assembly, including the fan stator vanes. It was concluded that it was feasible to utilize composite materials for this type structure but that the requirements imposed by replacing an existing metal design resulted in an inefficient composite design. It was concluded that if composites were to be effectively used in this type structure, the design must be tailored for composite application from the outset.

  19. The importance of observed gradients of air temperature and precipitation for modelling water supply projections of a glacierised watershed in the Nepalese Himalayas

    NASA Astrophysics Data System (ADS)

    Immerzeel, W. W.; Pellicciotti, F.; Bierkens, M. F.

    2012-12-01

    Precipitation and temperature vary strongly over short horizontal distances in mountain environments, yet observations are scarce and mostly limited to small numbers of valley stations. The scarcity of meteorological observations at high altitude is particularly problematic in the Himalayas, which play an essential role in the water supply of millions of people downstream. Water supply projections depend on hydrological models, ideally forced by spatial fields of precipitation and air temperature for the accurate simulation of rain and melt runoff. Hydrological models can easily be fitted with seemingly high accuracy to observed runoff, even when meteorological inputs are of poor quality, with detrimental effects, however, on the representation of processes. In this study we use the results of a field campaign conducted during the 2012 monsoon season in the Langtang glacierised catchment in the greater Himalaya of Nepal to illustrate the importance of observations of gradients of air temperature and precipitation in projections of mass balance, seasonal snow and runoff. During the field campaign temperature loggers, tipping buckets and a high altitude pluviometer and snow depth gauge were installed and the data are used to force and recalibrate a high resolution glacio-hydrological model. The results are compared to a model run forced and calibrated using data from a single meteorological station. We show that optimal calibrated parameters vary in response to the quality of input data used, and that internal processes are reproduced differently. It is concluded that short-term campaigns to monitor horizontal and vertical gradients in air temperature and precipitation have the potential to improve the correct process representation in glacio-hydrological models, contribute to an accurate definition of model parameters and subsequently improve the quality of projections of future water supply.

  20. Supply Rate and Equilibrium Inventory of Air Force Enlisted Personnel: A Simultaneous Model of the Accession and Retention Markets Incorporating Force Level Constraints. Final Report for Period July 1969-June 1976.

    ERIC Educational Resources Information Center

    DeVany, Arthur S.; And Others

    This research was designed to develop and test a model of the Air Force manpower market. The study indicates that previous manpower supply studies failed to account for simultaneous determination of enlistments and retentions and misinterpreted regressions as supply equations. They are, instead, reduced form equations resulting from joint…

  1. Better Duct Systems for Home Heating and Cooling; Building Technologies Program (Brochure)

    SciTech Connect

    2004-11-01

    Duct systems used in forced-air space-conditioning systems are a vital element in home energy efficiency. How well a system works makes a big difference in the cost and the effectiveness of heating and cooling a home.

  2. Introduction to Indoor Air Quality

    MedlinePlus

    ... as conditions caused by outdoor impacts (such as climate change). Many reports and studies indicate that the following ... Air Duct Cleaning Asthma Health, Energy Efficiency and Climate Change Flood Cleanup Home Remodel Indoor airPLUS Mold Radon ...

  3. The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity.

    PubMed

    Wargocki, P; Wyon, D P; Sundell, J; Clausen, G; Fanger, P O

    2000-12-01

    Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h-1. The temperature of 22 degrees C, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (P < 0.002) and the intensity of odour (P < 0.02), and increased the perceived freshness of air (P < 0.05). It also decreased the sensation of dryness of mouth and throat (P < 0.0006), eased difficulty in thinking clearly (P < 0.001) and made subjects feel generally better (P < 0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (P < 0.03). For each two-fold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged. PMID:11089327

  4. Articulated transition duct in turbomachine

    DOEpatents

    Flanagan, James Scott; McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Pentecost, Ronnie Ray

    2014-04-29

    Turbine systems are provided. A turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion and a downstream portion. The upstream portion extends from the inlet between an inlet end and an aft end. The downstream portion extends from the outlet between an outlet end and a head end. The turbine system further includes a joint coupling the aft end of the upstream portion and the head end of the downstream portion together. The joint is configured to allow movement of the upstream portion and the downstream portion relative to each other about or along at least one axis.

  5. Wave reflections from duct terminations.

    PubMed

    Selamet, A; Ji, Z L; Kach, R A

    2001-04-01

    The reflection coefficients and inertial end corrections of several duct terminations, including finite length duct extensions perpendicular to an infinite wall, as well as at a number of angles, curved interface surfaces, and annular cavities, are determined and analyzed in the absence of flow by employing the boundary element method. Predictions for the classical unflanged and flanged circular ducts show good agreement with analytical and computational results available in the literature. The predictions for curved interface surfaces (bellmouth or horn) are also consistent with the available experimental data. In view of its high reflection coefficient, the duct termination with an annular cavity may be suggested for the suppression of noise radiation in a specific frequency band or for an effective wave reflection from the termination. PMID:11325101

  6. Sound propagation in choked ducts

    NASA Technical Reports Server (NTRS)

    Hersh, A. S.; Liu, C. Y.

    1976-01-01

    The linearized equations describing the propagation of sound in variable area ducts containing flow are shown to be singular when the duct mean flow is sonic. The singularity is removed when previously ignored nonlinear terms are retained. The results of a numerical study, for the case of plane waves propagating in a one-dimensional converging-diverging duct, show that the sound field is adequately described by the linearized equations only when the axial mean flow Mach number at the duct throat M sub th 0.6. For M sub th 0.6, the numerical results showed that acoustic energy flux was not conserved. An attempt was made to extend the study to include the nonlinear behavior of the sound field. Meaningful results were not obtained due, primarily, to numerical difficulties.

  7. Reverse Flow Engine Core Having a Ducted Fan with Integrated Secondary Flow Blades

    NASA Technical Reports Server (NTRS)

    Kisska, Michael K. (Inventor); Princen, Norman H. (Inventor); Kuehn, Mark S. (Inventor); Cosentino, Gary B. (Inventor)

    2014-01-01

    Secondary air flow is provided for a ducted fan having a reverse flow turbine engine core driving a fan blisk. The fan blisk incorporates a set of thrust fan blades extending from an outer hub and a set of integral secondary flow blades extending intermediate an inner hub and the outer hub. A nacelle provides an outer flow duct for the thrust fan blades and a secondary flow duct carries flow from the integral secondary flow blades as cooling air for components of the reverse flow turbine engine.

  8. Flow duct for nuclear reactors

    DOEpatents

    Straalsund, Jerry L.

    1978-01-01

    Improved liquid sodium flow ducts for nuclear reactors are described wherein the improvement comprises varying the wall thickness of each of the walls of a polygonal tubular duct structure so that each of the walls is of reduced cross-section along the longitudinal center line and of a greater cross-section along wall junctions with the other walls to form the polygonal tubular configuration.

  9. Guide to Air Cleaners in the Home

    MedlinePlus

    ... Air Duct Cleaning Asthma Health, Energy Efficiency and Climate Change Flood Cleanup Home Remodel Indoor airPLUS Mold Radon ... menu Learn the Issues Air Chemicals and Toxics Climate Change Emergencies Greener Living Health and Safety Land and ...

  10. Turbofan aft duct suppressor study

    NASA Technical Reports Server (NTRS)

    Syed, A. A.; Motsinger, R. E.; Fiske, G. H.; Joshi, M. C.; Kraft, R. E.

    1983-01-01

    Suppressions due to acoustic treatment in the annular exhaust duct of a model fan were theoretically predicted and compared with measured suppressions. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Modal distributions of the fan noise source (fan-stator interaction only) were measured using in-duct modal probes. The flow profiles were also measured in the vicinity of the modal probes. The acoustic impedance of the single degree of freedom treatment was measured in the presence of grazing flow. The measured values of mode distribution of the fan noise source, the flow velocity profile and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions, under the assumption of uniform flow in the duct, compared well with the suppressions measured in the duct for all test conditions. The interaction modes generated by the rotor-stator interaction spanned a cut-off ratio range from nearly 1 to 7.

  11. Aeroacoustic interaction in a corrugated duct

    NASA Astrophysics Data System (ADS)

    Kop'ev, V. F.; Mironov, M. A.; Solntseva, V. S.

    2008-03-01

    The sound generation by an air flow in a corrugated tube is studied experimentally for different values of the corrugation pitch and different tube lengths. The Strouhal numbers of sound generated in different tubes with different flow velocities lie within 0.4-0.6. As the flow velocity increases, the Strouhal number decreases. The effect of sound absorption by an air flow in a corrugated duct is described: in a corrugated tube with a flow, at frequencies below the generation frequency, the absorption of sound produced by an external source is observed. A semiempirical model of aeroacoustic interaction in a corrugated tube is proposed. The model provides a qualitative agreement with the experiment.

  12. To Duct or Not to Duct: Evaluating the Space Conditioning Impacts of Heat Pump Water Heaters in the PNNL Lab Homes

    SciTech Connect

    Widder, Sarah H.; Parker, Graham B.; Peeks, B.; Sullivan, Greg; Shaffer, Scott

    2014-08-22

    Heat pump water heaters (HPWH) are a promising technology for substantially reducing water heating-related energy use in the residential sector. However, concerns have been raised regarding the impact of HPWHs on space conditioning energy when installed in conditioned space, primarily in northern climates. For example, the Northwest Energy Efficiency Alliance (NEEA’s) Northern Climate HPWH Specification, which describes the characteristics a HPWH must have to be incentivized in cold climates in the Pacific Northwest (PNW), requires exhaust ducting for their Tier II-specified products and both supply and exhaust ducting for the Tier III-specified product (NEEA 2013). However, these concerns and installation recommendations are based on modeling and comparative field data are not available to verify modeled performance. This study examines the overall performance and operation of two GE GeoSpring HPWHs in conditioned space in the matched pair of PNNL Lab Homes with no ducting, exhaust ducting, and full ducting (supply and exhaust) and explores the interactions between the HPWH and the home’s heating/cooling system. The data collected in this field evaluation suggest that previous modeling may not completely characterize the complex interactions of HPWHs, HVAC systems, and ducting. This report discusses the impact on space conditioning and water heater energy use of configuring an HPWH with exhaust only ducting or full ducting, as compared to an unducted HPWH. Additional cost analysis is necessary to assess the cost effectiveness of ducting and to make formal recommendations regarding appropriate installation of HPWHs in more varied scenarios.

  13. Evaluation of a high-temperature burner-duct-recuperator system

    NASA Astrophysics Data System (ADS)

    1990-07-01

    The U.S. Department of Energy's (DOE) Office of Industrial Technologies (OIT) sponsors research and development (R and D) to improve the energy efficiency of American industry and to provide for fuel flexibility. OIT has funded a multiyear R and D project by the Babcock and Wilcox Company (B and W) to design, fabricate, field test, and evaluate a high-temperature burner-duct-recuperator (HTBDR) system. This ceramic-based recuperator system recovers waste heat from the corrosive, high-temperature (2170 F) flue gas stream of a steel soaking pit to preheat combustion air to as high as 1700 F. The preheated air is supplied to a high-temperature burner. The B and W R and D program, which is now complete, involved several activities, including selecting and evaluating ceramic materials, designing the system, and developing and evaluating the prototype. In addition, a full-scale unit was tested at a B and W steel soaking pit. The full-scale system consisted of a modular single-stage ceramic recuperator, a conventional two-pass metallic recuperator, a high-temperature burner, fans, insulated ducting, and associated controls and instrumentation. The metallic recuperator preheated combustion air to about 750 F before it passed to the ceramic module. This technical case study describes the DOE/B and W recuperator project and highlights the field tests of the full-scale recuperator system. The document makes results of field tests and data analysis available to other researchers and private industry. It discusses project status, summarizes field tests, and reviews the potential effects the technology will have on energy use and system economics.

  14. Estimating evaporation duct heights from radar sea echo

    NASA Astrophysics Data System (ADS)

    Rogers, L. Ted; Hattan, Claude P.; Stapleton, Janet K.

    2000-07-01

    The evaporation duct is a downward refracting layer that results from the rapid decrease in humidity with respect to altitude occurring in the atmospheric surface layer above bodies of water. The evaporation duct affects radar detection ranges at frequencies of approximately 1 GHz and above. Models based on Monin-Obukhov similarity theory are usually used to calculate evaporation duct refractivity profiles from bulk measurements of air temperature, humidity, wind speed, and the sea surface temperature. Modeling results by Pappert et al. [1992] indicated that the falloff of radar sea echo as a function of range was an increasing function of the evaporation duct height. On the basis of those results, the authors proposed inferring the evaporation duct height by a slope fit to modeled clutter power, a nonlinear least squares inversion procedure. Data for testing the inversion procedure were obtained using the S band Space Range Radar at Wallops Island, Virginia. Evaporation duct heights were inferred from the radar data on the basis of the assumption of a range-independent evaporation duct height and sea clutter radar cross section (σ°). Validation data consist of buoy and boat in situ bulk measurements. The result of comparing the radar-inferred evaporation duct heights and those calculated from bulk measurements indicates that the radar-inferred duct heights are strongly correlated with those from the in situ measurements, but there is some uncertainty as to whether they are biased or unbiased. That uncertainty arises from the assumed dependence of σ° on the grazing angle ψ. That dependence is currently a matter of debate in the open literature, with the lower and upper ends of modeling results being σ° ∝ ψ0; and σ° ∝ ψ4, respectively. We show results for both dependencies and note that the σ° ∝ ψ0; provides the best agreement with our measurements. It should be noted that inferring the evaporation duct height from radar sea echo is a problem

  15. Micro-channels in the mastoid anatomy. Indications of a separate blood supply of the air cell system mucosa by micro-CT scanning.

    PubMed

    Cros, Olivier; Borga, Magnus; Pauwels, Elin; Dirckx, Joris J J; Gaihede, Michael

    2013-07-01

    The mastoid air cell system has traditionally been considered to have a passive role in gas exchange and pressure regulation of the middle ear possibly with some acoustic function. However, more evidence has focused on the mucosa of the mastoid, which may play a more active role in regulation of middle ear pressure. In this study we have applied micro-CT scanning on a series of three human temporal bones. This approach greatly enhances the resolution (40-60 μm), so that we have discovered anatomical details, which has not been reported earlier. Thus, qualitative analysis using volume rendering has demonstrated notable micro-channels connecting the surface of the compact bone directly to the mastoid air cells as well as forming a network of connections between the air cells. Quantitative analysis on 2D slices was employed to determine the average diameter of these micro-channels (158 μm; range = 40-440 μm) as well as their density at a localized area (average = 75 cm(-2); range = 64-97 cm(-2)). These channels are hypothesized to contain a separate vascular supply for the mastoid mucosa. However, future studies of the histological structure of the micro-channels are warranted to confirm the hypothesis. Studies on the mastoid mucosa and its blood supply may improve our knowledge of its physiological properties, which may have important implications for our understanding of the pressure regulation of the middle ear. This article is part of a special issue entitled "MEMRO 2012". PMID:23518400

  16. CASE STUDY OF DUCT RETROFIT OF A 1985 HOME AND GUIDELINES FOR ATTIC AND CRAWL SPACE DUCT SEALING

    SciTech Connect

    Boudreaux, Philip R; Christian, Jeffrey E; Jackson, Roderick K

    2012-01-01

    The U.S. Department of Energy (DOE) is fully committed to research for developing the information and capabilities necessary to provide cost-effective residential retrofits yielding 50% energy savings within the next several years. Heating, ventilation, and air conditioning (HVAC) is the biggest energy end use in the residential sector, and a significant amount of energy can be wasted through leaky ductwork in unconditioned spaces such as attics and crawl spaces. A detailed duct sealing case study is presented for one house along with nine brief descriptions of other duct retrofits completed in the mixed-humid climate. Costs and estimated energy savings are reported for most of the ten houses. Costs for the retrofits ranged from $0.92/ft2 to $1.80/ft2 of living space and estimated yearly energy cost savings due to the duct retrofits range from 1.8% to 18.5%. Lessons learned and duct sealing guidelines based on these ten houses, as well as close work with the HVAC industry in the mixed-humid climate of East Tennessee, northern Georgia, and south-central Kentucky are presented. It is hoped that the lessons learned and guidelines will influence local HVAC contractors, energy auditors, and homeowners when diagnosing or repairing HVAC duct leakage and will be useful for steering DOE s future research in this area.

  17. Laparoscopic common bile duct exploration.

    PubMed

    Vecchio, Rosario; MacFadyen, Bruce V

    2002-04-01

    In recent years, laparoscopic common bile duct exploration has become the procedure of choice in the management of choledocholithiasis in several laparoscopic centers. The increasing interest for this laparoscopic approach is due to the development of instrumentation and technique, allowing the procedure to be performed safely, and it is also the result of the revised role of endoscopic retrograde cholangiopancreatography, which has been questioned because of its cost, risk of complications and effectiveness. Many surgeons, however, are still not familiar with this technique. In this article we discuss the technique and results of laparoscopic common bile duct exploration. Both the laparoscopic transcystic approach and choledochotomy are discussed, together with the results given in the literature. When one considers the costs, morbidity, mortality and the time required before the patient can return to work, it would appear that laparoscopic cholecystectomy with common bile duct exploration is more favorable than open surgery or laparoscopic cholecystectomy with preoperative or postoperative endoscopic sphincterotomy. However, the technique requires advanced laparoscopic skills, including suturing, knot tying, the use of a choledochoscope, guidewire, dilators and balloon stone extractor. Although laparoscopic common bile duct exploration appears to be the most cost-effective method to treat common bile duct stones, it should be emphasized that this procedure is very challenging, and it should be performed by well-trained laparoscopic surgeons with experience in biliary surgery. PMID:11981684

  18. Evaporation duct refractivity profile from satellite meteorological data

    NASA Astrophysics Data System (ADS)

    Levadnyi, Iu.; Ivanov, V.; Shalyapin, V.

    The refractivity profile is initial data for the microwave propagation prediction models Evaporation duct height is usually used to characterize refractivity profile in the surface layer over sea The evaporation duct height is calculated using bulk measurement of air temperature wind speed humidity pressure at some level and sea surface temperature Four prevailing models LKB Liu-Katsaros-Businger RSHMU Russian State Hydro-Meteorological University optimized by us ECMWF European Center for Medium range Weather Forecast and COARE Coupled Ocean-Atmosphere Response Experiment were examined The results of computation using above mentioned models were compared with the direct refractometric measurements All measurements meteorological and refractometric were made by us during two marine expeditions First expedition was in the Atlantic ocean from March to May in latitude 22 circ-32° North and longitude 52 circ-65° West 29 measurements Second one was in the Indian ocean from December to February in latitude 0 circ-15° North and longitude 55 circ-80° East 94 measurements The approximation by least square-root method was carried out to compare the direct measurements of evaporation duct height with the results of computations The minimum square-root error is obtained for LKB model 2 59m for negative air-sea temperature difference 2 42m maximum - for ECMWF model 2 72m All models overestimate low evaporation duct heights and underestimate - high values This effect is least of all define in RSHMU

  19. Technology Solutions Case Study: Duct in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida

    SciTech Connect

    2014-09-01

    Forced-air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as attics or crawlspaces. Any leakage of air to or from the duct system in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raised ceiling or fur-up chase) or below the ceiling plane (dropped ceiling or fur-down) for the duct system. In this project, Building America Partnership for Improved Residential Construction team partnered with Tommy Williams Homes to implement an inexpensive, quick, and effective method of building a fur-down chase.

  20. Evaporation duct communication: Test Plan

    NASA Astrophysics Data System (ADS)

    Anderson, K. D.

    1991-02-01

    The Evaporation Duct Communication (EDCOM) project is an effort to provide an alternative ship-to-ship communications channel using the natural environment. A microwave communication link can be used on an over-the-water, over-the-horizon path through the evaporation duct. This report shows how a microwave communication link, operating at a range separation of more than twice the line-of-sight range, can be constructed. This link can achieve about 80-percent availability at a transmission frequency of 14.5 GHz and can be constructed using off-the-shelf RF equipment. Operation of this link will provide the first set of measurements of channel capacity that can be critically dependent on the existence of an oceanic evaporation duct. Construction of this link presents a unique opportunity to study and evaluate an alternative communications channel that can be used to alleviate naval battlegroup communications load.

  1. Congenital Atresia of Wharton's Duct.

    PubMed

    Hseu, Anne; Anne, Premchand; Anne, Samantha

    2016-02-01

    This is a case report of a three-month-old male who presented to clinic with a cystic lesion under the tongue. On clinical examination, a cystic lesion was observed in the, floor-of-mouth. The patient was referred to Paediatric Otorhinolaryngology service for further management. The differential diagnoses for floor-of-mouth lesions should be reviewed with primary focus on the Wharton's duct atresia and its management. It is crucial to recognize submandibular duct atresia in the primary Paediatric clinic in order to expedite management of lesion before complications arise including infection, enlargement of cyst, and feeding and breathing difficulties. PMID:27042492

  2. General Information about Extrahepatic Bile Duct Cancer

    MedlinePlus

    ... Bile Duct Cancer Treatment (PDQ®)–Patient Version General Information About Bile Duct Cancer Go to Health Professional ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  3. What Are the Key Statistics about Bile Duct Cancer?

    MedlinePlus

    ... for bile duct cancer? What are the key statistics about bile duct cancer? Bile duct cancer is ... it is when it is found. For survival statistics, see the section “ Survival statistics for bile duct ...

  4. Viscous flow computations for elliptical two-duct version of the SSME hot gas manifold

    NASA Technical Reports Server (NTRS)

    Roger, R. P.

    1986-01-01

    The objective of the effort was to numerically simulate viscous subsonic flow in a proposed elliptical two-duct version of the fuel side Hot Gas Manifold (HGM) for the Space Shuttle Main Engine (SSME). The numerical results were to complement both water flow and air flow experiments in the two-duct geometry performed at NASA-MSFC and Rocketdyne. The three-dimensional character of the HGM consists of two essentially different geometries. The first part of the construction is a concentric shell duct structure which channels the gases from a turbine exit into the second part comprised of two cylindrically shaped transfer ducts. The initial concentric shell portion can be further subdivided into a turnaround section and a bowl section. The turnaround duct (TAD) changes the direction of the mean flow by 180 degress from a smaller radius to a larger radius duct which discharges into the bowl. The cylindrical transfer ducts are attached to the bowl on one side thus providing a plane of symmetry midway between the two. Centerline flow distance from the TAD inlet to the transfer duct exit is approximately two feet. Details of the approach used to numerically simulate laminar or turbulent flow in the HGM geometry are presented. Computational results are presented and discussed.

  5. Moulded calculus of common bile duct mimicking a stenosis

    PubMed Central

    Brocki, Marian; Śmigielski, Jacek

    2014-01-01

    Bile duct stenosis, in most cases, appears to be the consequence of pancreatic head, ampulla of Vater and bile duct tumours, cholangitis sclerosans, as well as iatrogenic damages, which may all be diagnosed during endoscopic retrograde cholangiopancreatography (ERCP). In very rare cases the restriction may result from an atypically shaped wedged stone. This situation creates many diagnostic problems, which in the majority of cases can be solved using imaging studies. However, in some patients even a significant extension of diagnostic procedures may not lead to a correct diagnosis. We present a diagnostically difficult case of a deposit imitating restriction. We present a 70-year-old woman with common bile duct restriction undiagnosed despite several ultrasound examinations (USG), computed tomography (CT), double magnetic resonance cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP). Only after the third ERCP examination a fragmented, by formerly introduced prosthesis, deposit, imitating narrowing, was revealed. Identification of bile duct deposits depends on their composition, localisation and the imaging techniques used. Pigment calculi with atypical shape, bile density, air density or surrounding tissue density are very difficult to diagnose. Thus, the sensitivity of common bile duct stone detection in USG, CT, MRCP and endoscopic ultrasound (EUS) is 5–88%; 6–88%; 73–97%; and 84–98%, respectively. Moreover, ERCP may not diagnose the character of the restriction even in 5.2% up to 30% of the patients. Consequently, assessment of diagnosis in a number of patients is difficult. A deposit imitating common bile duct (CBD) restriction is a rare, difficult to diagnose phenomenon, which should be taken into account during differential diagnosis of CBD restrictions. PMID:25061493

  6. Hydrogeologic setting, water levels, and quality of water from supply wells at the US Marine Corps Air Station, Cherry Point, North Carolina

    USGS Publications Warehouse

    Lloyd, O.B., Jr.; Daniel, C. C., III

    1988-01-01

    The Marine Corps Air Station is located in the Coastal Plain province of North Carolina. Four freshwater aquifers of sand and limestone underlie the area to a depth of about 500 feet. Saline water occurs below this depth. The aquifers are separated by three confining units that are thin and discontinuous in the southern part. Water supply is obtained from 195- to 330 feet wells in the Castle Hayne aquifer. Many wells are near landfills that have received hazardous wastes. Groundwater withdrawals have reduced hydraulic heads in the Castle Hayne some 20 feet around active production wells, creating potential for downward movement of contaminated water from the surface and for upward movement of saline water that occurs at depth. Chemical analyses of water from the Castle Hayne aquifer indicate median concentrations of iron and manganese are 0.78 and 0.08 milligrams per liter, respectively, and lead and (or) nickel exceed drinking water standards in three wells. Chloride increased from 10 to more than 40 milligrams per liter in the deepest operating well over a 45-year period. Benzene concentrations range from 0.5 to 1.9 milligrams per liter in the southern part of the Air Station but were below the 5 milligrams per liter maximum contaminant level for drinking water. Fatty acids were found in concentrations as much as 28 micrograms per liter in water from wells in an area centered around the intersection of Roosevelt Boulevard and Slocum Road. Resampling is needed to verify all constituents that indicate contamination.

  7. Wind Turbine With Concentric Ducts

    NASA Technical Reports Server (NTRS)

    Muhonen, A. J.

    1983-01-01

    Wind Turbine device is relatively compact and efficient. Converging inner and outer ducts increase pressure difference across blades of wind turbine. Turbine shaft drives alternator housed inside exit cone. Suitable for installation on such existing structures as water towers, barns, houses, and commercial buildings.

  8. Vitellointestinal Duct Anomalies in Infancy

    PubMed Central

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Background: Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5–9 of intrauterine life. Methods: This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Results: Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Conclusion: Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality. PMID:27433448

  9. A cost benefit approach to reactor sizing and nutrient supply for biotrickling filters for air pollution control

    SciTech Connect

    Deshusses, M.A.; Cox, H.H.J.

    1999-07-01

    In the present paper, a general model was developed that allows the selection of the most cost-effective operation of biotrickling filters for air pollution control. The model was demonstrated for a typical case of industrial pollution: 10,000 m{sup 3} h{sup {minus}1} airstream contaminated with 1.5 g m{sup {minus}3} toluene. The reactor design and operation were optimized with respect to the nutrient (nitrate) loading, which influenced the pollutant elimination capacity and the rate of reactor clogging by biomass. Integration of all pertinent costs and experimental data into the model demonstrated that biotrickling filtration was very competitive compared to conventional treatment technologies. For the case studied, a treatment cost optimum was obtained at a nutrient loading of 8 g N-nitrate per cubic meter bed volume per day. The range of cost effective treatment was 4 to 30 g N-nitrate m{sup {minus}3} d{sup {minus}1}. Overall, the general approach presented herein is widely applicable for the determination of the best reactor design and the optimum reactor operating conditions.

  10. Design and performance of duct acoustic treatment

    NASA Technical Reports Server (NTRS)

    Motsinger, R. E.; Kraft, R. E.

    1991-01-01

    The procedure for designing acoustic treatment panels used to line the walls of aircraft engine ducts and for estimating the resulting suppression of turbofan engine duct noise is discussed. This procedure is intended to be used for estimating noise suppression of existing designs or for designing new acoustic treatment panels and duct configurations to achieve desired suppression levels.

  11. 46 CFR 116.610 - Ventilation ducts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... requirements relative to the passage of smoke and flame as the fire control boundary penetrated; (2) A steel duct penetrating an A-Class fire control boundary must be of at least 11 USSG, and a steel duct... duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary...

  12. 46 CFR 116.610 - Ventilation ducts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... requirements relative to the passage of smoke and flame as the fire control boundary penetrated; (2) A steel duct penetrating an A-Class fire control boundary must be of at least 11 USSG, and a steel duct... duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary...

  13. Improved Duct Systems Task Report with StageGate 2 Analysis

    SciTech Connect

    Moyer, Neil; Stroer, Dennis

    2007-12-31

    This report is about Building America Industrialized Housing Partnership's work with two industry partners, Davalier Homes and Southern Energy Homes, in constructing and evaluating prototype interior duct systems. Issues of energy performance, comfort, DAPIA approval, manufacturability and cost is addressed. A stage gate 2 analysis addresses the current status of project showing that there are still refinements needed to the process of incorporating all of the ducts within the air and thermal boundaries of the envelope.

  14. Development of TiN Coating System for Long Beam Ducts of Accelerators

    NASA Astrophysics Data System (ADS)

    Shibata, Kyo; Hisamatsu, Hiromi; Kanazawa, Ken-Ichi; Suetsugu, Yusuke; Shirai, Mitsuru

    A Titanium Nitride (TiN) coating system for long beam ducts of accelerators was developed to reduce the secondary electron yield (SEY) from the inner surface and to mitigate the electron cloud effect. Coating was carried out by DC magnetron sputtering of pure titanium in argon (2.0 Pa) and nitrogen (0.5 Pa) atmospheres. A copper beam duct with a maximum length of 3.6 m was set vertically, and a titanium rod as a cathode was suspended from the top along the central axis of the duct. A movable solenoid coil with a length of 0.8 m externally supplied a magnetic field of 16 mT to accommodate the long duct. By moving the solenoid coil at specified time intervals, the TiN film was uniformly coated on the inner surface. The thickness of the coating was 200 nm, and the temperature of the ducts during the coating was 130°C. Several coated ducts were installed into the KEKB positron ring during the summer shutdown in 2007. In the subsequent beam operation, the reduction of electrons in the coated duct was confirmed.

  15. Pressure losses across multiple fittings in ventilation ducts.

    PubMed

    Ai, Z T; Mak, C M

    2013-01-01

    The accurate prediction of pressure losses across in-duct fittings is of significance in relation to the accurate sizing and good energy efficiency of air-delivery systems. Current design guides provide design methods and data for the prediction of pressure losses only for a single and isolated fitting. This study presents an investigation of pressure losses across multiple interactive in-duct fittings in a ventilation duct. A laboratory measurement of pressure losses across one fitting and multiple fittings in a ventilation duct is carried out. The pressure loss across multiple interactive fittings is lower than that across multiple similar individual fittings, while the percentage decrease is dependent on the configuration and combination of the fittings. This implies that the pressure loss across multiple closely mounted fittings calculated by summing the pressure losses across individual fittings, as provided in the ASHRAE handbook and the CIBSE guide, is overpredicted. The numerical prediction of the pressure losses across multiple fittings using the large-eddy simulation (LES) model shows good agreement with the measured data, suggesting that this model is a useful tool in ductwork design and can help to save experimental resources and improve experimental accuracy and reliability. PMID:24385871

  16. Pressure Losses across Multiple Fittings in Ventilation Ducts

    PubMed Central

    Ai, Z. T.; Mak, C. M.

    2013-01-01

    The accurate prediction of pressure losses across in-duct fittings is of significance in relation to the accurate sizing and good energy efficiency of air-delivery systems. Current design guides provide design methods and data for the prediction of pressure losses only for a single and isolated fitting. This study presents an investigation of pressure losses across multiple interactive in-duct fittings in a ventilation duct. A laboratory measurement of pressure losses across one fitting and multiple fittings in a ventilation duct is carried out. The pressure loss across multiple interactive fittings is lower than that across multiple similar individual fittings, while the percentage decrease is dependent on the configuration and combination of the fittings. This implies that the pressure loss across multiple closely mounted fittings calculated by summing the pressure losses across individual fittings, as provided in the ASHRAE handbook and the CIBSE guide, is overpredicted. The numerical prediction of the pressure losses across multiple fittings using the large-eddy simulation (LES) model shows good agreement with the measured data, suggesting that this model is a useful tool in ductwork design and can help to save experimental resources and improve experimental accuracy and reliability. PMID:24385871

  17. 21. STATION 70.5 OF MST, WEST SIDE. AIRCONDITIONING DUCT AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. STATION 70.5 OF MST, WEST SIDE. AIR-CONDITIONING DUCT AT TOP; POWER BOX ON RIGHT; WINCH ON LEFT. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. Designing insulation for cryogenic ducts

    NASA Astrophysics Data System (ADS)

    Love, C. C.

    1984-03-01

    It is pointed out that the great temperature difference between the outside of a cryogenic duct and the liquified gas it carries can cause a high heat input unless blocked by a high thermal resistance. High thermal resistance for lines needing maximum insulation is provided by metal vacuum jackets. Low-density foam is satisfactory in cases in which higher heat input can be tolerated. Attention is given to the heat transfer through a duct vacuum jacket, the calculation of heat input and the exterior surface's steady-state temperature for various thicknesses of insulation, the calculation of the heat transfer through gimbal jackets, and design specifications regarding the allowable pressure rise in the jacket's annular space.

  19. Tear-ducts in wine

    NASA Astrophysics Data System (ADS)

    Bush, John W. M.

    1999-11-01

    We examine the radial spoke pattern evident in the meniscus region in glasses of strong alcoholic beverages exhibiting the `tears-in-wine' phenomenon. We demonstrate that the pattern results from ridge-like elevations of the free surface which are supported by evaporatively-driven Marangoni convection in the meniscus region. Vortices associated with the convective motions are aligned in the radial direction by the surface tension gradient responsible for the generation of tears. The radial flow is focussed into the ridges, which thus serve as the principal conduits of fluid for the tears; consequently, we refer to the ridges as `tear-ducts'. The phenomenon is examined experimentally, and a numerical model of evaporatively-driven Marangoni convection is developed which reproduces the salient features of the tear-duct phenomenon.

  20. HAARP-Induced Ionospheric Ducts

    SciTech Connect

    Milikh, Gennady; Vartanyan, Aram

    2011-01-04

    It is well known that strong electron heating by a powerful HF-facility can lead to the formation of electron and ion density perturbations that stretch along the magnetic field line. Those density perturbations can serve as ducts for ELF waves, both of natural and artificial origin. This paper presents observations of the plasma density perturbations caused by the HF-heating of the ionosphere by the HAARP facility. The low orbit satellite DEMETER was used as a diagnostic tool to measure the electron and ion temperature and density along the satellite orbit overflying close to the magnetic zenith of the HF-heater. Those observations will be then checked against the theoretical model of duct formation due to HF-heating of the ionosphere. The model is based on the modified SAMI2 code, and is validated by comparison with well documented experiments.

  1. Small duct primary sclerosing cholangitis without inflammatory bowel disease is genetically different from large duct disease

    PubMed Central

    Næss, Sigrid; Björnsson, Einar; Anmarkrud, Jarl A.; Al Mamari, Said; Juran, Brian D.; Lazaridis, Konstantinos N.; Chapman, Roger; Bergquist, Annika; Melum, Espen; Marsh, Steven G. E.; Schrumpf, Erik; Lie, Benedicte A.; Boberg, Kirsten Muri; Karlsen, Tom H.; Hov, Johannes R.

    2014-01-01

    Background & aims Small duct primary sclerosing cholangitis (PSC) is phenotypically a mild version of large duct PSC, but it is unknown whether these phenotypes share aetiology. We aimed to characterize their relationship by investigating genetic associations in the HLA complex, which represent the strongest genetic risk factors in large duct PSC. Methods Four classical HLA loci (HLA-A, HLA-B, HLA-C, HLA-DRB1) were genotyped in 87 small duct PSC patients, 485 large duct PSC patients and 1117 controls across three geographical regions. Results HLA-DRB1*13:01 (OR=2.0, 95% CI 1.2–3.4, P=0.01) and HLA-B*08 (OR=1.6, 95% CI 1.1–2.4, P=0.02) were significantly associated with small duct PSC compared with healthy controls. Based on the observed frequency of HLA-B*08 in small duct PSC, the strongest risk factor in large duct PSC, an estimated 32% (95% CI 4%–65%) of this population can be hypothesized to represent early stages or mild variants of large duct PSC. This subgroup may be constituted by small duct PSC patients with inflammatory bowel disease (IBD), which greatly resembled large duct PSC in its HLA association. In contrast, small duct PSC without IBD was only associated with HLA-DRB1*13:01(P=0.03) and was otherwise distinctly dissimilar from large duct PSC. Conclusions Small duct PSC with IBD resembles large duct PSC in its HLA association and may represent early stages or mild variants of large duct disease. Different HLA associations in small duct PSC without IBD could indicate that this subgroup is a different entity. HLA-DRB1*13:01 may represent a specific risk factor for inflammatory bile duct disease. PMID:24517468

  2. Laser Microdissection of the Alveolar Duct Enables Single-Cell Genomic Analysis

    PubMed Central

    Bennett, Robert D.; Ysasi, Alexandra B.; Belle, Janeil M.; Wagner, Willi L.; Konerding, Moritz A.; Blainey, Paul C.; Pyne, Saumyadipta; Mentzer, Steven J.

    2014-01-01

    Complex tissues such as the lung are composed of structural hierarchies such as alveoli, alveolar ducts, and lobules. Some structural units, such as the alveolar duct, appear to participate in tissue repair as well as the development of bronchioalveolar carcinoma. Here, we demonstrate an approach to conduct laser microdissection of the lung alveolar duct for single-cell PCR analysis. Our approach involved three steps. (1) The initial preparation used mechanical sectioning of the lung tissue with sufficient thickness to encompass the structure of interest. In the case of the alveolar duct, the precision-cut lung slices were 200 μm thick; the slices were processed using near-physiologic conditions to preserve the state of viable cells. (2) The lung slices were examined by transmission light microscopy to target the alveolar duct. The air-filled lung was sufficiently accessible by light microscopy that counterstains or fluorescent labels were unnecessary to identify the alveolar duct. (3) The enzymatic and microfluidic isolation of single cells allowed for the harvest of as few as several thousand cells for PCR analysis. Microfluidics based arrays were used to measure the expression of selected marker genes in individual cells to characterize different cell populations. Preliminary work suggests the unique value of this approach to understand the intra- and intercellular interactions within the regenerating alveolar duct. PMID:25309876

  3. Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort

    SciTech Connect

    Widder, Sarah H.; Petersen, Joseph M.; Parker, Graham B.; Baechler, Michael C.

    2014-07-21

    Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes’ space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

  4. Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes

    SciTech Connect

    Beach, R.; Burdick, A.

    2014-03-01

    This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance. IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations. These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.

  5. Cholangiocytes and blood supply

    PubMed Central

    Gaudio, Eugenio; Franchitto, Antonio; Pannarale, Luigi; Carpino, Guido; Alpini, Gianfranco; Francis, Heather; Glaser, Shannon; Alvaro, Domenico; Onori, Paolo

    2006-01-01

    The microvascular supply of the biliary tree, the peribiliary plexus (PBP), stems from the hepatic artery branches and flows into the hepatic sinusoids. A detailed three-dimensional study of the PBP has been performed by using the Scanning Electron Microscopy vascular corrosion casts (SEMvcc) technique. Considering that the PBP plays a fundamental role in supporting the secretory and absorptive functions of the biliary epithelium, their organization in either normalcy and pathology is explored. The normal liver shows the PBP arranged around extra- and intrahepatic biliary tree. In the small portal tract PBP was characterized by a single layer of capillaries which progressively continued with the extrahepatic PBP where it showed a more complex vascular network. After common duct ligation (BDL), progressive modifications of bile duct and PBP proliferation are observed. The PBP presents a three-dimensional network arranged around many bile ducts and appears as bundles of vessels, composed by capillaries of homogeneous diameter with a typical round mesh structure. The PBP network is easily distinguishable from the sinusoidal network which appears normal. Considering the enormous extension of the PBP during BDL, the possible role played by the Vascular Endothelial Growth Factor (VEGF) is evaluated. VEGF-A, VEGF-C and their related receptors appeared highly immunopositive in proliferating cholangiocytes of BDL rats. The administration of anti-VEGF-A or anti-VEGF-C antibodies to BDL rats as well as hepatic artery ligation induced a reduced bile duct mass. The administration of rVEGF-A to BDL hepatic artery ligated rats prevented the decrease of cholangiocyte proliferation and VEGF-A expression as compared to BDL control rats. These data suggest the role of arterial blood supply of the biliary tree in conditions of cholangiocyte proliferation, such as it occurs during chronic cholestasis. On the other hand, the role played by VEGF as a tool of cross-talk between

  6. Refraction of acoustic duct waveguide modes by exhaust jets.

    NASA Technical Reports Server (NTRS)

    Mani, R.

    1973-01-01

    The refraction of acoustic duct waveguide modes emitted from the open end of a semiinfinite rectangular duct by a jet-like exhaust flow is studied theoretically. The problem is formulated as a Wiener-Hopf problem and is ultimately solved by an approximate method due to Carrier and Koiter. Continuity of transverse acoustic particle displacement and of acoustic pressure is assumed at the jet/still-air interface. The solution exhibits several features of the acoustics of moving media such as a source convection effect, zones of relative silence, and simple refraction. Plots of far-field directivity patterns are presented for several cases and show refraction effects to be important even at modest exhaust Mach numbers of order 0.3. Only subsonic exhaust Mach numbers are considered.

  7. Duct wall impedance control as an advanced concept for acoustic impression

    NASA Technical Reports Server (NTRS)

    Dean, P. D.; Tester, B. J.

    1975-01-01

    Models and tests on an acoustic duct liner system which has the property of controlled-variable acoustic impedance are described. This is achieved by a novel concept which uses the effect of steady air flow through a multi-layer, locally reacting, resonant-cavity absorber. The scope of this work was limited to a 'proof of concept.' The test of the concept was implemented by means of a small-scale, square-section flow duct facility designed specifically for acoustic measurements, with one side of the duct acoustically lined. The test liners were designed with the aid of previously established duct acoustic theory and a semi-empirical impedance model of the liner system. Over the limited range tested, the liner behaved primarily as predicted, exhibiting significant changes in resistance and reactance, thus providing the necessary concept validation.

  8. Parotid salivary duct stenosis following caudal maxillectomy.

    PubMed

    Mestrinho, Lisa A; Faísca, Pedro B; Niza, Maria M R E

    2014-01-01

    Parotid salivary duct dilation was diagnosed in a 9-year-old male dog. The dog had undergone caudal maxillectomy on the ipsilateral side 2-years prior to presentation. Treatment consisted of parotid salivary duct excision and superficial parotidectomy that lead to the resolution of clinical signs. Transient facial neuropraxia was observed immediately after surgery and resolved spontaneously after 2-weeks. Parotid salivary duct dilation should be considered as a chronic postoperative complication following caudal maxillectomy. PMID:24902412

  9. Results of borehole geophysical logging and hydraulic tests conducted in Area D supply wells, former US Naval Air Warfare Center, Warminster, Pennsylvania

    USGS Publications Warehouse

    Sloto, Ronald A.; Grazul, Kevin E.

    1998-01-01

    Borehole geophysical logging, aquifer tests, and aquifer-isolation (packer) tests were conducted in four supply wells at the former U.S. Naval Air Warfare Center (NAWC) in Warminster, PA to identify the depth and yield of water-bearing zones, occurrence of borehole flow, and effect of pumping on nearby wells. The study was conducted as part of an ongoing evaluation of ground-water contamination at the NAWC. Caliper, natural-gamma, single-point resistance, fluid resistivity, and fluid temperature logs and borehole television surveys were run in the supply wells, which range in depth from 242 to 560 ft (feet). Acoustic borehole televiewer and borehole deviation logs were run in two of the wells. The direction and rate of borehole-fluid movement under non-pumping conditions were measured with a high-resolution heatpulse flowmeter. The logs were used to locate water-bearing fractures, determine probable zones of vertical borehole-fluid movement, and determine the depth to set packers. An aquifer test was conducted in each well to determine open-hole specific capacity and the effect of pumping the open borehole on water levels in nearby wells. Specific capacities ranged from 0.21 to 1.7 (gal/min)/ft (gallons per minute per foot) of drawdown. Aquifer-isolation tests were conducted in each well to determine depth-discrete specific capacities and to determine the effect of pumping an individual fracture or fracture zone on water levels in nearby wells. Specific capacities of individual fractures and fracture zones ranged from 0 to 2.3 (gal/min)/ft. Most fractures identified as water-producing or water-receiving zones by borehole geophysical methods produced water when isolated and pumped. All hydrologically active fractures below 250 ft below land surface were identified as water-receiving zones and produced little water when isolated and pumped. In the two wells greater then 540 ft deep, downward borehole flow to the deep water-receiving fractures is caused by a large

  10. Lightweight Forms for Epoxy/Aramid Ducts

    NASA Technical Reports Server (NTRS)

    Mix, E. W.; Anderson, A. N.; Bedford, Donald L., Sr.

    1986-01-01

    Aluminum mandrels easy to remove. Lightweight aluminum mandrel for shaping epoxy/aramid ducts simplifies and speeds production. In new process, glass-reinforced epoxy/aramid cloth wrapped on aluminum mandrel. Stainless-steel flanges and other hardware fitted on duct and held by simple tooling. Entire assembly placed in oven to cure epoxy. After curing, assembly placed in alkaline bath dissolves aluminum mandrel in about 4 hours. Epoxy/aramid shell ready for use as duct. Aluminum mandrel used to make ducts of various inside diameters up to 6 in. Standard aluminum forms used. Conventional tube-bending equipment produces requisite curves in mandrels.

  11. Traumatic injury of the thoracic duct.

    PubMed

    Guzman, A E; Rossi, L; Witte, C L; Smyth, S

    2002-03-01

    Injuries to the thoracic duct are infrequent but may become life-threatening when chylous leakage persists. This report describes 6 patients with such injuries in whom the leakage resolved spontaneously in one, was corrected using microsurgical lymphatic repair or lymphatic-venous anastomosis in two, successfully treated either by ligation of the thoracic duct or insertion of a peritoneovenous shunt in two, and was eventually controlled after bilateral pleurodesis and thoracic duct ligation by insertion of a peritoneo-venous shunt in one. Conventional lymphography is superior to lymphoscintigraphy and is usually required to document disruption of the thoracic duct. PMID:11939572

  12. Generator stator core vent duct spacer posts

    DOEpatents

    Griffith, John Wesley; Tong, Wei

    2003-06-24

    Generator stator cores are constructed by stacking many layers of magnetic laminations. Ventilation ducts may be inserted between these layers by inserting spacers into the core stack. The ventilation ducts allow for the passage of cooling gas through the core during operation. The spacers or spacer posts are positioned between groups of the magnetic laminations to define the ventilation ducts. The spacer posts are secured with longitudinal axes thereof substantially parallel to the core axis. With this structure, core tightness can be assured while maximizing ventilation duct cross section for gas flow and minimizing magnetic loss in the spacers.

  13. Extent of fungal growth on fiberglass duct liners with and without biocides under challenging environmental conditions.

    PubMed

    Samimi, Behzad S; Ross, Kristen

    2003-03-01

    Eight brands of fiberglass duct liners, including three that contained biocides, were exposed to challenging environmental conditions that would promote fungal growth. Twenty-four rectangular sheet metal ducts in three groups of eight ducts per group were lined with the eight selected liners. Each group of ducts was exposed to one of the three test conditions within an environmental chamber for a period of 15 days. These conditions were a) 75 percent RH, b) 75 percent RH plus water spray, c) 75 percent RH plus dry nutrient, and d) 75 percent RH plus water plus nutrient. Viable spores of Aspergillus niger were aerosolized into each duct as seed. On the 16th day, air and surface samples for fungal spores were collected from inside ducts. The results of air sampling using N6 sampler and visual inspection indicated that two out of three biocide-containing liners, Permacote and Toughgard, inhibited fungal growth but only under condition A. The third biocide-containing liner, Aeroflex Plus, was effective even when it was wet (conditions A and B). All three biocide-containing liners failed to inhibit fungal growth under conditions C and D. Among the five other types of liners that did not contain biocides, ATCO Flex with a smooth Mylar coating was more preferable, exhibiting lower fungal activity during conditions A, B, and C. All liners failed under condition D when nutrient and water were added together. Surface sampling using adhesive tape failed to produce representative results, apparently due to rough/porous surface of duct liners. It was concluded that duct liners with biocide treatment could be less promoting to microbial growth under high humidity as long as their surfaces remain clean and water-free. A liner with an impermeable and smooth surface seems to be less subject to microbial growth under most conditions than biocide-containing liners having porous and/or rough surfaces. PMID:12573965

  14. Supply Management.

    ERIC Educational Resources Information Center

    Marine Corps Inst., Washington, DC.

    Developed as part of the Marine Corps Institute (MCI) correspondence training program, this course on supply management is designed to provide the supply chief with an understanding of the fundamental functions of supply management as it applies to a supply office. Introductory materials include specific information for MCI students, a course…

  15. Wastefree in-duct FGD

    SciTech Connect

    Nelson, S. Jr.

    1995-12-31

    The first generation of easily-retrofitable duct-injection technologies experienced problems with modest performance, particulate non-compliance, and difficult waste disposal. A new sorbent concept, called Fluesorbent, has been developed specifically to address these problems. Based on a new lime sorbent material, the technology results in 80+% SO{sub 2} removal, net particulate reductions, and a valuable agricultural by-product instead of wastes. A 6,500 acfm, 2-MWe Fluesorbent pilot plant was recently constructed at Ohio Edison`s R.E. Burger station. This paper describes the technology and the Burger demonstration project.

  16. Numerical characterization of the hydrodynamics and thermal behavior of air flow in flexible air distribution system

    NASA Astrophysics Data System (ADS)

    Gharehdaghi, Samad; Moujaes, Samir

    2013-10-01

    Flexible duct air distribution systems are used in a large percentage of residential and small commercial buildings in the United States . Very few empirical or predictive data are available though to help provide the HVAC design engineer with reliable information . Moreover, because of the ducts flexibility, the shapes of these ducts offer a different set of operating fluid flow and thermal conditions from traditional smooth metal ducts. Hence, both the flow field and heat transfer through this kind of ducts are much more complex and merit to be analyzed from a numerical predictive approach. The aim of this research paper is to compute some of the hydrodynamic and heat transfer characteristics of the air flow inside these ducts over a range of Re numbers commonly used in the flow conditions of these air distribution systems. The information resulting from this CFD simulation, where a κ-ɛ turbulent model is used to predict the flow conditions, provide pressure drop and average convective heat transfer coefficients that exist in these ducts and was compared to previously found data. Circulation zones in the depressions of these ducts are found to exist which are suspected of influencing the pressured drop and heat transfer coefficients as compared to smooth ducts. The results show that fully developed conditions exist much earlier with regard to the inlet for both hydrodynamic and thermal entrance regions than what would be expected in smooth ducts under the same turbulent conditions.

  17. Optimization of the mechanical performance of a two-duct semicircular duct system--part 1: dynamics and duct dimensions.

    PubMed

    Muller, M; Verhagen, J H G

    2002-06-21

    The classical representation of the semicircular duct system consists of three separate duct circuits. The ducts are, however, in reality, hydrodynamically interconnected. Muller & Verhagen (1988a,b) derived equations for the mechanical behaviour of an interconnected system with three ducts (anterior, posterior and horizontal). An analytical solution of these equations would, however, be too complex to provide surveyable formulae. A system of two interconnected ducts avoids this complexity whilst keeping the essentials of the coupling of ducts intact. The solution of the equation of motion leads to expressions for time constants and maximal endolymph excursions which are functions of morphological parameters, viz. the ratios of radii (gamma) and lengths (lambda) of the common vestibular part (crus commune or utriculus) and the ducts. The system possesses two short time constants which are shown to have similar values. The maximum endolymph displacements in the two ducts after a steplike stimulus are the products of the respective initial velocities and combinations of time constants. The initial velocities depend strongly on the position of the labyrinth with respect to the excitating rotation vector. Measured data of gamma and lambda are compared with the theoretical results. For gamma, excellent agreement was found. lambda is treated elsewhere. PMID:12151258

  18. Measure Guideline: Sealing and Insulating of Ducts in Existing Homes

    SciTech Connect

    Aldrich, R.; Puttagunta, S.

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  19. What's New in Bile Duct Cancer Research and Treatment?

    MedlinePlus

    ... Topic Additional resources for bile duct cancer What’s new in bile duct cancer research and treatment? Bile ... is tumor blood vessels. Bile duct tumors need new blood vessels to grow beyond a certain size. ...

  20. Measure Guideline. Sealing and Insulating Ducts in Existing Homes

    SciTech Connect

    Aldrich, R.; Puttagunta, S.

    2011-12-01

    This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

  1. Do We Know What Causes Bile Duct Cancer?

    MedlinePlus

    ... duct cancer be prevented? Do we know what causes bile duct cancer? We don’t know the exact cause of ... to top » Guide Topics What Is Bile Duct Cancer? Causes, Risk Factors, and Prevention Early Detection, Diagnosis, and ...

  2. Navier-Stokes analysis and experimental data comparison of compressible flow within ducts

    NASA Technical Reports Server (NTRS)

    Harloff, G. J.; Reichert, B. A.; Sirbaugh, J. R.; Wellborn, S. R.

    1992-01-01

    Many aircraft employ ducts with centerline curvature or changing cross-sectional shape to join the engine with inlet and exhaust components. S-ducts convey air to the engine compressor from the intake and often decelerate the flow to achieve an acceptable Mach number at the engine compressor by increasing the cross-sectional area downstream. Circular-to-rectangular transition ducts are used on aircraft with rectangular exhaust nozzles to connect the engine and nozzle. To achieve maximum engine performance, the ducts should minimize flow total pressure loss and total pressure distortion at the duct exit. Changes in the curvature of the duct centerline or the duct cross-sectional shape give rise to streamline curvature which causes cross stream pressure gradients. Secondary flows can be caused by deflection of the transverse vorticity component of the boundary layer. This vortex tilting results in counter-rotating vortices. Additionally, the adverse streamwise pressure gradient caused by increasing cross-sectional area can lead to flow separation. Vortex pairs have been observed in the exit planes of both duct types. These vortices are due to secondary flows induced by pressure gradients resulting from streamline curvature. Regions of low total pressure are produced when the vortices convect boundary layer fluid into the main flow. The purpose of the present study is to predict the measured flow field in a diffusing S-duct and a circular-to-rectangular transition duct with a full Navier-Stokes computer program, PARC3D, and to compare the numerical predictions with new detailed experimental measurements. The work was undertaken to extend previous studies and to provide additional CFD validation data needed to help model flows with strong secondary flow and boundary layer separation. The S-duct computation extends the study of Smith et al, and Harloff et al, which concluded that the computation might be improved by using a finer grid and more advanced turbulence models

  3. Investigation in the 7-By-10 Foot Wind Tunnel of Ducts for Cooling Radiators Within an Airplane Wing, Special Report

    NASA Technical Reports Server (NTRS)

    Harris, Thomas A.; Recant, Isidore G.

    1938-01-01

    An investigation was made in the NACA 7- by 10-foot wind tunnel of a large-chord wing model with a duct to house a simulated radiator suitable for a liquid-cooled engine. The duct was expanded to reduce the radiator losses, and the installation of the duct and radiator was made entirely within the wing to reduce form and interference drag. The tests were made using a two-dimensional flow set-up with a full-span duct and radiator. Section aerodynamic characteristics of the basic airfoil are given and also curves showing the characteristics of the various duct-radiator combinations. An expression for efficiency, the primary criterion of merit of any duct, and the effect of the several design parameters of the duct-radiator arrangement are discussed. The problem of throttling is considered and a discussion of the power required for cooling is included. It was found that radiators could be mounted in the wing and efficiently pass enough air for cooling with duct outlets located at any point from 0.25c to 0.70c from the wing leading edge on the upper surface. The duct-inlet position was found to be critical and, for maximum efficiency, had to be at the stagnation point of the airfoil and to change with flight attitude. The flow could be efficiently throttled only by a simultaneous variation of duct inlet and outlet sizes and of inlet position. It was desirable to round both inlet and outlet lips. With certain arrangements of duct, the power required for cooling at high speed was a very low percentage of the engine power.

  4. Salivary duct carcinoma of parotid gland.

    PubMed

    Kinnera, Vijay Sreedhar Babu; Mandyam, Kumaraswamy Reddy; Chowhan, Amit Kumar; Nandyala, Rukmangadha; Bobbidi, Venkata Phaneendra; Vutukuru, Venkatarami Reddy

    2009-07-01

    A 40-year old male presented with rapidly growing swelling in the right parotid region. Based on the fine needle aspiration cytology report of adenocarcinoma not otherwise specified, superficial parotidectomy was performed, which showed the features of salivary duct carcinoma by histopathological examination. The smears were reviewed to identify the potential pitfalls in the cytological diagnosis of salivary duct carcinoma. PMID:21887008

  5. Salivary duct carcinoma of parotid gland

    PubMed Central

    Kinnera, Vijay Sreedhar Babu; Mandyam, Kumaraswamy Reddy; Chowhan, Amit Kumar; Nandyala, Rukmangadha; Bobbidi, Venkata Phaneendra; Vutukuru, Venkatarami Reddy

    2009-01-01

    A 40-year old male presented with rapidly growing swelling in the right parotid region. Based on the fine needle aspiration cytology report of adenocarcinoma not otherwise specified, superficial parotidectomy was performed, which showed the features of salivary duct carcinoma by histopathological examination. The smears were reviewed to identify the potential pitfalls in the cytological diagnosis of salivary duct carcinoma. PMID:21887008

  6. Double-duct liquid metal magnetohydrodynamic engine

    DOEpatents

    Haaland, Carsten M.

    1995-01-01

    An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has-four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.

  7. Double-duct liquid metal magnetohydrodynamic engine

    DOEpatents

    Haaland, Carsten M.

    1997-01-01

    An internal combustion, liquid metal (LM) magnetohydrodynamic (MHD) engine and an alternating current (AC) magnetohydrodynamic generator, are used in combination to provide useful AC electric energy output. The engine design has four pistons and a double duct configuration, with each duct containing sodium potassium liquid metal confined between free pistons located at either end of the duct. The liquid metal is forced to flow back and forth in the duct by the movement of the pistons, which are alternatively driven by an internal combustion process. In the MHD generator, the two LM-MHD ducts pass in close proximity through a Hartmann duct with output transformer. AC power is produced by operating the engine with the liquid metal in the two generator ducts always flowing in counter directions. The amount of liquid metal maintained in the ducts may be varied. This provides a variable stroke length for the pistons. The engine/generator provides variable AC power at variable frequencies that correspond to the power demands of the vehicular propulsion. Also the engine should maintain nearly constant efficiency throughout the range of power usage. Automobiles and trucks could be powered by the invention, with no transmission or power converter devices being required.

  8. Tear-Duct Obstruction and Surgery

    MedlinePlus

    ... could block a duct, but reconstructive surgery right after the accident or injury may prevent this. Signs of Blocked Tear Ducts ... kids. It may take up to a week after surgery before symptoms improve. Your doctor will give you antibiotic ointment or drops along with ... Injuries Pinkeye (Conjunctivitis) Retinopathy of Prematurity Preparing Your Child ...

  9. Predicting vibrational failure of flexible ducting

    NASA Technical Reports Server (NTRS)

    Henry, R. H.

    1971-01-01

    Technique applies to liquid or gas transfer through flexible ducting and proves valuable in high velocity fluid flow cases. Fluid mechanism responsible for free bellows vibrational excitation also causes flexible hose oscillation. Static pressure stress influences flexible ducting fatigue life and is considered separately.

  10. Rocket-in-a-Duct Performance Analysis

    NASA Technical Reports Server (NTRS)

    Schneider, Steven J.; Reed, Brian D.

    1999-01-01

    An axisymmetric, 110 N class, rocket configured with a free expansion between the rocket nozzle and a surrounding duct was tested in an altitude simulation facility. The propellants were gaseous hydrogen and gaseous oxygen and the hardware consisted of a heat sink type copper rocket firing through copper ducts of various diameters and lengths. A secondary flow of nitrogen was introduced at the blind end of the duct to mix with the primary rocket mass flow in the duct. This flow was in the range of 0 to 10% of the primary massflow and its effect on nozzle performance was measured. The random measurement errors on thrust and massflow were within +/-1%. One dimensional equilibrium calculations were used to establish the possible theoretical performance of these rocket-in-a-duct nozzles. Although the scale of these tests was small, they simulated the relevant flow expansion physics at a modest experimental cost. Test results indicated that lower performance was obtained at higher free expansion area ratios and longer ducts, while, higher performance was obtained with the addition of secondary flow. There was a discernable peak in specific impulse efficiency at 4% secondary flow. The small scale of these tests resulted in low performance efficiencies, but prior numerical modeling of larger rocket-in-a-duct engines predicted performance that was comparable to that of optimized rocket nozzles. This remains to be proven in large-scale, rocket-in-a-duct tests.

  11. Fabrication process of a high temperature polymer matrix engine duct

    NASA Technical Reports Server (NTRS)

    Pratt, R. D.; Wilson, A. J.

    1985-01-01

    The process that was used in the molding of an advanced composite outer by-pass duct planned for the F404 engine is discussed. This duct was developed as a potential replacement for the existing titanium duct in order to reduce both the weight and cost of the duct. The composite duct is now going into the manufacturing technology portion of the program. The duct is fabricated using graphite cloth impregnated with the PMR-15 matrix system.

  12. Fuel nozzle assembly for use as structural support for a duct structure in a combustor of a gas turbine engine

    DOEpatents

    Wiebe, David J; Fox, Timothy A

    2015-03-31

    A fuel nozzle assembly for use in a combustor apparatus of a gas turbine engine. An outer housing of the fuel nozzle assembly includes an inner volume and provides a direct structural connection between a duct structure and a fuel manifold. The duct structure defines a flow passage for combustion gases flowing within the combustor apparatus. The fuel manifold defines a fuel supply channel therein in fluid communication with a source of fuel. A fuel injector of the fuel nozzle assembly is provided in the inner volume of the outer housing and defines a fuel passage therein. The fuel passage is in fluid communication with the fuel supply channel of the fuel manifold for distributing the fuel from the fuel supply channel into the flow passage of the duct structure.

  13. Film condensation in a horizontal rectangular duct

    NASA Technical Reports Server (NTRS)

    Lu, Qing; Suryanarayana, N. V.

    1992-01-01

    Condensation heat transfer in an annular flow regime with and without interfacial waves was experimentally investigated. The study included measurements of heat transfer rate with condensation of vapor flowing inside a horizontal rectangular duct and experiments on the initiation of interfacial waves in condensation, and adiabatic air-liquid flow. An analytical model for the condensation was developed to predict condensate film thickness and heat transfer coefficients. Some conclusions drawn from the study are that the condensate film thickness was very thin (less than 0.6 mm). The average heat transfer coefficient increased with increasing the inlet vapor velocity. The local heat transfer coefficient decreased with the axial distance of the condensing surface, with the largest change at the leading edge of the test section. The interfacial shear stress, which consisted of the momentum shear stress and the adiabatic shear stress, appeared to have a significant effect on the heat transfer coefficients. In the experiment, the condensate flow along the condensing surface experienced a smooth flow, a two-dimensional wavy flow, and a three-dimensional wavy flow. In the condensation experiment, the local wave length decreased with the axial distance of the condensing surface and the average wave length decreased with increasing inlet vapor velocity, while the wave speed increased with increasing vapor velocity. The heat transfer measurements are reliable. And, the ultrasonic technique was effective for measuring the condensate film thickness when the surface was smooth or had waves of small amplitude.

  14. Salivary Duct Cyst: Histo-pathologic Correlation

    PubMed Central

    Vinayachandran, Divya; Sankarapandian, Sathasivasubramanian

    2013-01-01

    Non-neoplastic cysts of the salivary glands are uncommon and represent 2-5% of all salivary gland lesions. They are mainly mucoceles or salivary duct cysts. Unlike a mucocele, which is surrounded by granulation tissue, the salivary duct cyst is lined by epithelium. Salivary duct cysts are more common in the oral minor salivary glands and rarely occur in the major salivary glands, show a marked predilection for the superficial lobe of the parotid, and represent 10% of all salivary gland cysts. Neoplastic differentiation of the lining of the salivary duct cyst has been reported. We report a case of a salivary duct cyst of the left parotid gland, with a review of radiographic and histopathologic features. PMID:23878772

  15. Salivary Duct Cyst: Histo-pathologic Correlation.

    PubMed

    Vinayachandran, Divya; Sankarapandian, Sathasivasubramanian

    2013-01-01

    Non-neoplastic cysts of the salivary glands are uncommon and represent 2-5% of all salivary gland lesions. They are mainly mucoceles or salivary duct cysts. Unlike a mucocele, which is surrounded by granulation tissue, the salivary duct cyst is lined by epithelium. Salivary duct cysts are more common in the oral minor salivary glands and rarely occur in the major salivary glands, show a marked predilection for the superficial lobe of the parotid, and represent 10% of all salivary gland cysts. Neoplastic differentiation of the lining of the salivary duct cyst has been reported. We report a case of a salivary duct cyst of the left parotid gland, with a review of radiographic and histopathologic features. PMID:23878772

  16. Laparoscopic Anatomical Left Hepatectomy for Intrahepatic Bile Duct Papillary Mucinous Cystadenoma With Intraoperative Vascular Repair: A Case Report.

    PubMed

    Li, Hongyu; Peng, Bing

    2016-02-01

    Laparoscopic hepatectomy has been widely performed for patients with benign liver tumors such as hepatic hemangioma, focal nodular hyperplasia, and hepatic adenoma.We here present a case of a 78-year-old female patient who was initially admitted to our department due to fever and jaundice for 2 days. Abdominal enhanced computed tomography scan showed intrahepatic and extrahepatic bile duct dilatation with liver atrophy of left lobe. Unenhanced nodules were seen within the left intrahepatic bile duct. Ultrasonography revealed intrahepatic and extrahepatic bile duct dilatation with viscous fluid, tubular adenoma? Tumor markers including alpha fetoprotein, carcinoembryonic antigen, and CA19-9 were normal. Preoperative total bilirubin was 64.4 mmol/L.Laparoscopic anatomical left hepatectomy and common bile duct exploration were performed. In this procedure, a lot of mucus was seen within the common bile duct and left intrahepatic bile duct. No bile duct stones were found after the exploration. During parenchymal transection, intraoperative hemorrhage from middle hepatic vein was met, and we repaired middle hepatic vein by laparoscopic suture (5-0 Prolene). No air embolism and hypotension were met. This operation took 232 minutes and estimated blood loss was 300 mL. Postoperative ultrasonography indicated a normal outflow of middle hepatic vein and there was no stricture. The patient's postoperative course was uneventful and was discharged on the 6th day after surgery. Postoperative pathological diagnosis was intrahepatic bile duct papillary mucinous cystadenoma. PMID:26871845

  17. Electromagnetic propagation in PEC and absorbing curved S-ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.

    1988-01-01

    A finite-element Galerkin formulation has been developed to study transverse magnetic (TM) wave propagation in 2-D S-curved ducts with both perfectly conducting and absorbing walls. The reflection and transmission at the entrances and the exits of the curved ducts are determined by coupling the finite-element solutions in the curved ducts to the eigenfunctions of an infinite, uniform, perfectly conducting duct. Example solutions are presented for a double mitred and S-ducts of various lengths. The length of the S-duct is found to significantly effect the reflective characteristics of the duct. Also, the effect of curvature on an absorbing duct is illustrated.

  18. MINIMIZING DECOMPOSITION OF VAPORIZED HYDROGEN PEROXIDE IN CLEAN GALVANIZED STEEL DUCTING: IMPLICATIONS FOR BIOLOGICAL DECONTAMINATION

    SciTech Connect

    Verce, M F; Jayaraman, B; Ford, T D; Fisher, S E; Gadgil, A J; Carlsen, T M

    2007-09-07

    This work examined the behavior of vaporous hydrogen peroxide (VHP) in clean, room-scale galvanized steel (GS) and polyvinylchloride-coated steel air ducts, to understand how it might be used to decontaminate larger ventilation systems. VHP injected into the GS duct decreased in concentration along the length of the duct, whereas VHP concentrations in the polyvinylchloride coated duct remained essentially constant, suggesting that VHP decomposed at the GS surface. However, decomposition was reduced at lower temperatures ({approx} 22 C) and higher flow rates ({approx} 80 actual cubic meter per hour). A computational fluid dynamics model incorporating reactive transport was used to estimate surface VHP concentrations where contamination is likely to reside, and also showed how bends encourage VHP decomposition. Use of G. stearothermophilus indicators, in conjunction with model estimates, indicated that a concentration-contact time of {approx} 100 mg/L H{sub 2}O{sub 2}(g){center_dot}min was required to achieve a 6 log reduction of indicator spores in clean GS duct, at 30 C. When VHP is selected for building decontamination, this work suggests the most efficacious strategy may be to decontaminate GS ducting separately from the rest of the building, as opposed to a single decontamination event in which the ventilation system is used to distribute VHP throughout the entire building.

  19. Mixed convection heat and mass transfer in radially rotating rectangular ducts

    SciTech Connect

    Lee, K.T.; Yan, W.M.

    1998-11-27

    Heat transfer in rotating ducts is encountered in many engineering applications, such as cooling of turbomachinery, gas turbines, and other rotating systems. The present work investigates mixed convection heat and mass transfer in the entrance region of radially rotating rectangular ducts with water film evaporation along the porous duct walls. Mechanisms of secondary vortex development in the ducts under various conditions are examined by a vorticity-velocity numerical method. Emphasis is placed on the rotation effects, including both Coriolis and centrifugal buoyancy forces, and the mass diffusion effect on the flow structure and heat transfer characteristics. Results are presented in particular for an air-water vapor system under various conditions. Predicted results show that the effects of liquid film evaporation along the porous duct walls on the mixed convection heat transfer are rather substantial. The magnitude of the evaporative latent heat transfer may be 10 times greater than that of sensible heat transfer. The predictions also demonstrate that the distributions of Nu, Sh{sub z}, and fRe are closely related to the emergence, disappearance, growth, and decay of the rotating-induced secondary vortices. Additionally, a higher Nu{sub z} is found for a rectangular duct with a larger aspect ratio ({gamma} = 2) due to the relatively stronger secondary flows.

  20. Field investigation of duct system performance in California light commercial buildings

    SciTech Connect

    Delp, W.W.; Matson, N.E.; Tschudy, E.

    1997-12-09

    This paper discusses field measurements of duct system performance in fifteen systems located in eight northern California buildings. Light commercial buildings, one- and two-story with package roof-top HVAC units, make up approximately 50% of the non-residential building stock in the U.S. Despite this fact little is known about the performance of these package roof-top units and their associated ductwork. These simple systems use similar duct materials and construction techniques as residential systems (which are known to be quite leaky). This paper discusses a study to characterize the buildings, quantify the duct leakage, and analyze the performance of the ductwork in these types of buildings. The study tested fifteen systems in eight different buildings located in northern California. All of these buildings had the ducts located in the cavity between the drop ceiling and the roof deck. In 50% of these buildings, this cavity was functionally outside the building`s air and thermal barriers. The effective leakage area of the ducts in this study was approximately 2.6 times that in residential buildings. This paper looks at the thermal analysis of the ducts, from the viewpoint of efficiency and thermal comfort. This includes the length of a cycle, and whether the fan is always on or if it cycles with the cooling equipment. 66% of the systems had frequent on cycles of less than 10 minutes, resulting in non-steady-state operation.

  1. An inlet/sampling duct for airborne OH and sulfuric acid measurements

    NASA Astrophysics Data System (ADS)

    Eisele, F. L.; Mauldin, R. L.; Tanner, D. J.; Fox, J. R.; Mouch, T.; Scully, T.

    1997-12-01

    An inlet assembly has been designed, tested, and used for the airborne measurements of OH and sulfuric acid. The inlet sampling duct, which incorporates a shroud connected to two nested, restricted flow ducts, slows air velocity by approximately a factor of 16 while maintaining a uniform and well-defined flow. Qualitative wind tunnel tests showed that an inlet shroud that incorporates a 3:1 inner surface and 4.5:1 outer elliptical front surface can straighten the airflow at angles of attack of up to 18°-20° with no visible signs of turbulence. Tests using a Pitot tube to scan the flow velocity profile of the restricted flow ducts showed that the shroud, coupled to inlet ducts, could slow the flow and provide a relatively flat average velocity profile across the central portion of the ducts at angles of attack up to 17°. Tests performed using a chemical tracer showed that at angles of attack where the Pitot tube measurements began to indicate slight flow instabilities (17°-24°), there was no mixing from the walls into the center of the inlet. The inlet assembly also possesses the ability to produce a fairly uniform concentration of OH in the relatively constant velocity portion of the inner duct for instrument calibration. Actual measurements of rapidly changing OH and H2SO4 provide both additional evidence of proper inlet operation and new insight into H2SO4 production and loss in and around clouds.

  2. Computational Fluid Dynamics Analysis of Flexible Duct Junction Box Design

    SciTech Connect

    Beach, Robert; Prahl, Duncan; Lange, Rich

    2013-12-01

    IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away from the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.

  3. CHARACTERIZATION OF LEAK PATHWAYS IN THE BELOW GRADE DUCTS OF THE BROOKHAVEN GRAPHITE RESEARCH REACTOR USING PERFLUOROCARBON TRACERS.

    SciTech Connect

    HEISER,J.; SULLIVAN,T.; KALB,P.; MILIAN,L.; WILKE,R.; NEWSON,C.; LILIMPAKIS,M.

    2001-04-01

    The focus of this program was the characterization of the soils beneath the main air ducts connecting the exhaust plenums with the Fan House. The air plenums experienced water intrusion during BGRR operations and after shutdown. The water intrusions were attributed to rainwater leaks into degraded parts of the system and to internal cooling water system leaks. As part of the overall characterization efforts, a state-of-the-art gaseous perfluorocarbon tracer technology was utilized to characterize leak pathways from the ducts. This in turn suggests what soil regions under or adjacent to the ductwork should be emphasized in the characterization process. Knowledge of where gaseous tracers leak from the ducts yields a conservative picture of where water transport, out of or into, the ducts might have occurred.

  4. Turbofan engine with a low pressure turbine driven supercharger in a bypass duct operated by a fuel rich combustor and an afterburner

    NASA Technical Reports Server (NTRS)

    Bartos, James W. (Inventor)

    1999-01-01

    A multiple bypass turbofan engine includes a core Brayton Cycle gas generator with a fuel rich burning combustor and is provided with a variable supercharged bypass duct around the gas generator with a supercharging means in the supercharged bypass duct powered by a turbine not mechanically connected to the gas generator. The engine further includes a low pressure turbine driven forward fan upstream and forward of an aft fan and drivingly connected to a low pressure turbine by a low pressure shaft, the low pressure turbine being aft of and in serial flow communication with the core gas generator. A fan bypass duct is disposed radially outward of the core engine assembly and has first and second inlets disposed between the forward and aft fans. An inlet duct having an annular duct wall is disposed radially inward of the bypass duct and connects the second inlet to the bypass duct. A supercharger means for compressing air is drivingly connected to the low pressure turbine and is disposed in the inlet duct. A secondary combustor or augmentor is disposed in an exhaust duct downstream of and in fluid flow communication with the bypass duct and the gas generator.

  5. A preliminary study on the application of remotely sensed SST in locating evaporation duct height

    NASA Astrophysics Data System (ADS)

    Baig, Muhammad Hasan Ali; Wang, Zhenhui; Zhang, Lifu; Yang, Lu

    2012-10-01

    Refractivity happens due to stratification in the lower boundary layer over oceans due to variability of moisture, temperature, wind and sea surface temperature which collectively may lead to generate evaporation duct. The evaporation duct has a significant impact on the spread of electromagnetic waves in the atmosphere over oceans both from the meteorological and military point of view. This ducting sometimes supports normal propagation of radar signals and sometimes may cause distortion and attenuation of signals depending on the height of evaporation duct. This leads to over-estimation and under-estimation of rainfall by weather radar meteorologically and for other targets militarily. The aim of this study was not only to locate evaporation duct height but also to check the efficiency of Weather Research and Forecasting Model (WRF) and Babin's model so that results may be used in applying correction measures for precise identification of targets by radar. In this study by utilizing the high vertical resolution of WRF for the simulation of different meteorological parameters, the Babin's method was used for calculating the evaporation duct height over South China Sea for the two months, April and July. Very clear duct heights were calculated at different areas over sea in different time domains. Study reveals that maximum height existed in the month of April although July was rich with different EDHs in different regions in contrast to April. It was found that in most of the cases EDH was higher or maximum when relative humidity was comparatively lower and air temperature and wind speed were comparatively higher. This study paves a way for futuristic study of evaporation duct monitoring and forecasting by assimilation of remote sensing data especially through that of Geostationary satellites by incorporating verification measures from radar.

  6. Advanced Turbofan Duct Liner Concepts

    NASA Technical Reports Server (NTRS)

    Bielak, Gerald W.; Premo, John W.; Hersh, Alan S.

    1999-01-01

    The Advanced Subsonic Technology Noise Reduction Program goal is to reduce aircraft noise by 10 EPNdB by the year 2000 relative, to 1992 technology. The improvement goal for nacelle attenuation is 25% relative to 1992 technology by 1997 and 50% by 2000. The Advanced Turbofan Duct Liner Concepts Task work by Boeing presented in this document was in support of these goals. The basis for the technical approach was a Boeing study conducted in 1993-94 under NASA/FAA contract NAS1-19349, Task 6, investigating broadband acoustic liner concepts. As a result of this work, it was recommended that linear double layer, linear and perforate triple layer, parallel element, and bulk absorber liners be further investigated to improve nacelle attenuations. NASA LaRC also suggested that "adaptive" liner concepts that would allow "in-situ" acoustic impedance control also be considered. As a result, bias flow and high-temperature liner concepts were also added to the investigation. The major conclusion from the above studies is that improvements in nacelle liner average acoustic impedance characteristics alone will not result in 25% increased nacelle noise reduction relative to 1992 technology. Nacelle design advancements currently being developed by Boeing are expected to add 20-40% more acoustic lining to hardwall regions in current inlets, which is predicted to result in and additional 40-80% attenuation improvement. Similar advancements are expected to allow 10-30% more acoustic lining in current fan ducts with 10-30% more attenuation expected. In addition, Boeing is currently developing a scarf inlet concept which is expected to give an additional 40-80% attenuation improvement for equivalent lining areas.

  7. ASU nitrogen sweep gas in hydrogen separation membrane for production of HRSG duct burner fuel

    DOEpatents

    Panuccio, Gregory J.; Raybold, Troy M.; Jamal, Agil; Drnevich, Raymond Francis

    2013-04-02

    The present invention relates to the use of low pressure N2 from an air separation unit (ASU) for use as a sweep gas in a hydrogen transport membrane (HTM) to increase syngas H2 recovery and make a near-atmospheric pressure (less than or equal to about 25 psia) fuel for supplemental firing in the heat recovery steam generator (HRSG) duct burner.

  8. EVALUATING THE POTENTIAL EFFICACY OF AN ANTIMICROBIAL-CONTAINING SEALANT ON DUCT LINER AND GALVANIZED STEEL

    EPA Science Inventory

    The article gives results of an evaluation of the potential efficacy of an antimicrobial-containing sealant on fibrous-glass duct liner (FGDL) and galvanized steel (GS) as used in heating, ventilating, and air-conditioning (HVAC) systems. HVAC systems become dirty to various degr...

  9. Development of an Experimental Rig for Investigation of Higher Order Modes in Ducts

    NASA Technical Reports Server (NTRS)

    Gerhold, Carl H.; Cabell, Randolph H.; Brown, Martha C.

    2006-01-01

    Continued progress to reduce fan noise emission from high bypass ratio engine ducts in aircraft increasingly relies on accurate description of the sound propagation in the duct. A project has been undertaken at NASA Langley Research Center to investigate the propagation of higher order modes in ducts with flow. This is a two-pronged approach, including development of analytic models (the subject of a separate paper) and installation of a laboratory-quality test rig. The purposes of the rig are to validate the analytical models and to evaluate novel duct acoustic liner concepts, both passive and active. The dimensions of the experimental rig test section scale to between 25% and 50% of the aft bypass ducts of most modern engines. The duct is of rectangular cross section so as to provide flexibility to design and fabricate test duct liner samples. The test section can accommodate flow paths that are straight through or offset from inlet to discharge, the latter design allowing investigation of the effect of curvature on sound propagation and duct liner performance. The maximum air flow rate through the duct is Mach 0.3. Sound in the duct is generated by an array of 16 high-intensity acoustic drivers. The signals to the loudspeaker array are generated by a multi-input/multi-output feedforward control system that has been developed for this project. The sound is sampled by arrays of flush-mounted microphones and a modal decomposition is performed at the frequency of sound generation. The data acquisition system consists of two arrays of flush-mounted microphones, one upstream of the test section and one downstream. The data are used to determine parameters such as the overall insertion loss of the test section treatment as well as the effect of the treatment on a modal basis such as mode scattering. The methodology used for modal decomposition is described, as is a description of the mode generation control system. Data are presented which demonstrate the performance

  10. Duct Remediation Program: Remediation operations and implementation

    SciTech Connect

    Beckman, T.d.; Davis, M.M.; Karas, T.M.

    1992-11-01

    Plutonium holdup material has accumulated in the process ventilation duct systems at Rocky Flats. Non-Destructive Assay (NDA) measurements identified ducts containing this material. The Defense Nuclear Facility Safety Board and the Department of Energy established the criteria for remediation of these ducts. A remediation team was assembled and a program plan created. This program plan included activities such as fissile material accumulation identification, criticality safety assessments, radiation dose determinations, facility safety evaluations, prevention of future accumulation, and removal of holdup material. Several operational considerations had to be evaluated in determining completion of remediation.

  11. Magnetospheric whistler ducts observed by ISIS satellites

    NASA Technical Reports Server (NTRS)

    Ondoh, T.

    1976-01-01

    The latitudinal width of the magnetospheric whistler duct has been estimated by the first and final invariant latitudes of whistler echoes and the conservation of the magnetic flux for the centered dipole field, using 105 whistler echoes in ISIS VLF data received at Kashima, Japan for 1972-1973. The latitudinal distribution of whistler duct occurrence shows a maximum at invariant latitudes of 40-45 degrees near the maximum occurrence latitude of ground whistlers. The radial width of magnetospheric whistler duct in the geomagnetically equatorial plane increases with invariant latitude of the geomagnetic flux tube in which whistlers propagate.

  12. 40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Are duct burners and waste heat recovery units covered by subpart YYYY? 63.6092 Section 63.6092 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES...

  13. 40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Are duct burners and waste heat recovery units covered by subpart YYYY? 63.6092 Section 63.6092 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES...

  14. Natural Flow Air Cooled Photovoltaics

    NASA Astrophysics Data System (ADS)

    Tanagnostopoulos, Y.; Themelis, P.

    2010-01-01

    Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. We performed experiments using a prototype based on three silicon photovoltaic modules placed in series to simulate a typical sloping building roof with photovoltaic installation. In this system the air flows through a channel on the rear side of PV panels. The potential for increasing the heat exchange from the photovoltaic panel to the circulating air by the addition of a thin metal sheet (TMS) in the middle of air channel or metal fins (FIN) along the air duct was examined. The operation of the device was studied with the air duct closed tightly to avoid air circulation (CLOSED) and the air duct open (REF), with the thin metal sheet (TMS) and with metal fins (FIN). In each case the experiments were performed under sunlight and the operating parameters of the experimental device determining the electrical and thermal performance of the system were observed and recorded during a whole day and for several days. We collected the data and form PV panels from the comparative diagrams of the experimental results regarding the temperature of solar cells, the electrical efficiency of the installation, the temperature of the back wall of the air duct and the temperature difference in the entrance and exit of the air duct. The comparative results from the measurements determine the improvement in electrical performance of the photovoltaic cells because of the reduction of their temperature, which is achieved by the naturally circulating air.

  15. Error analysis for duct leakage tests in ASHRAE standard 152P

    SciTech Connect

    Andrews, J.W.

    1997-06-01

    This report presents an analysis of random uncertainties in the two methods of testing for duct leakage in Standard 152P of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). The test method is titled Standard Method of Test for Determining Steady-State and Seasonal Efficiency of Residential Thermal Distribution Systems. Equations have been derived for the uncertainties in duct leakage for given levels of uncertainty in the measured quantities used as inputs to the calculations. Tables of allowed errors in each of these independent variables, consistent with fixed criteria of overall allowed error, have been developed.

  16. Transmission of wave energy in curved ducts

    NASA Technical Reports Server (NTRS)

    Rostafinski, W.

    1973-01-01

    A formation of wave energy flow was developed for motion in curved ducts. A parametric study over a range of frequencies determined the ability of circular bends to transmit energy for the case of perfectly rigid walls.

  17. How Is Bile Duct Cancer Diagnosed?

    MedlinePlus

    ... line through which a different kind of contrast dye (IV contrast) is injected. This helps better outline ... common bile duct. A small amount of contrast dye is injected through the tube to help outline ...

  18. Treatment Options for Extrahepatic Bile Duct Cancer

    MedlinePlus

    ... checked to measure the amounts of bilirubin and alkaline phosphatase released into the blood by the liver. ... which a stent (a thin, flexible tube or metal tube) is placed in the bile duct to ...

  19. Treatment Option Overview (Extrahepatic Bile Duct Cancer)

    MedlinePlus

    ... checked to measure the amounts of bilirubin and alkaline phosphatase released into the blood by the liver. ... which a stent (a thin, flexible tube or metal tube) is placed in the bile duct to ...

  20. Stages of Extrahepatic Bile Duct Cancer

    MedlinePlus

    ... checked to measure the amounts of bilirubin and alkaline phosphatase released into the blood by the liver. ... which a stent (a thin, flexible tube or metal tube) is placed in the bile duct to ...

  1. Bile Duct (Cholangiocarcinoma) Cancer: Radiation Therapy

    MedlinePlus

    ... form of radiation for bile duct cancer. External beam radiation therapy (EBRT) This type of radiation therapy ... determine the correct angles for aiming the radiation beams and the proper dose of radiation. The treatment ...

  2. Intraoperative cholangiography and bile duct injury.

    PubMed

    Sarli, L; Costi, R; Roncoroni, L

    2006-01-01

    We are not in agreement with the opinion that the credit for excellent results after laparoscopic cholecystectomy is to be attributed to the routine performing of intraoperative cholangiography. We performed 2538 laparoscopic cholecystectomies without routine intraoperative cholangiography and we obtained very low rate and severity of common bile duct injuries: there was a total of four common bile duct injuries (0.16%), in no case was the injury a major transaction, and injuries were detected intraoperatively and easily repaired with a T-tube. Cholangiography could prevent bile duct transaction, but that it is not necessary for intraoperative cholangiography to be routinely performed for this purpose. It is sufficient for intraoperative cholangiography to be performed whenever the surgeon is in doubt as to the biliary anatomy or common bile duct clearance, and that when dissection of the cholecystic peduncle proves difficult he does not hesitate to convert to open access. PMID:16333543

  3. Investigation of heat transfer in porous duct

    NASA Astrophysics Data System (ADS)

    Athani, Abdulgaphur; Khan, T. M. Yunus

    2016-05-01

    Investigation of heat transfer in a square porous duct is carried out. The porous medium is sandwiched between inner and outer surface of a square duct. The flow is assumed to follow the Darcy law. The governing momentum and energy equations are non-dimensionalised and then converted to algebraic form of equations using finite element method. Galerkin method is used to transform the partial differential equations into simpler algebraic equations then solved in a iterative manner to arrive at the solution. The results are presented with respect to various geometric and physical parameters such as depth of porous medium, Rayleigh number etc. It is found that the isotherms and the streamlines take symmetrical position along the vertical central line of square duct. The isotherms are penetrated into deeper area at upper half of duct as compared to lower half.

  4. Model for coal dust duct explosions

    SciTech Connect

    Pickles, J.H.

    1982-01-01

    A theoretical discussion is given of the propagation of a dust explosion in a linear duct or pipeline. The particular aim is to investigate the experimental observation that propagating explosions are much harder to initiate in small laboratory scale ducts than in, say, coal mine galleries. A model is proposed in which a turbulent mixing phenomenon first identified by G.I. Taylor gives, for large ducts, very high flame velocities, which in turn lead to large fluid velocities and further increases in flame velocity. In small ducts, the time scale of the turbulent mixing is less than the time needed for the burning of individual coal particles. The particle burning time becomes an additional constraint on the rate of flame propagation and the development of explosions is inhibited.

  5. Rotating Rake Turbofan Duct Mode Measurement System

    NASA Technical Reports Server (NTRS)

    Sutliff, Daniel L.

    2005-01-01

    An experimental measurement system was developed and implemented by the NASA Glenn Research Center in the 1990s to measure turbofan duct acoustic modes. The system is a continuously rotating radial microphone rake that is inserted into the duct. This Rotating Rake provides a complete map of the acoustic duct modes present in a ducted fan and has been used on a variety of test articles: from a low-speed, concept test rig, to a full-scale production turbofan engine. The Rotating Rake has been critical in developing and evaluating a number of noise reduction concepts as well as providing experimental databases for verification of several aero-acoustic codes. More detailed derivation of the unique Rotating Rake equations are presented in the appendix.

  6. [Isolated neurofibroma of the common bile duct].

    PubMed

    Carbia, S; Pagola, J; Flaster, N; Guida, A; Jufe, L; González, B; Caniparoli, A

    1995-01-01

    The neurogenic tumors in the biliary tract are rare and usually are amputation neuroma that occur after cholecystectomy. We describe a case of isolated neurofibroma of the common bile duct in a young man not cholecystectomized. The patient suffered recurrent episodes of abdominal pain, vomiting and weight loss without clinical signs of Von Recklinghausen's disease or jaundice. The hepatogram was normal. The echography indicated a solid formation with obstruction of the proximal common bile duct. In the ERCP the stenosis was found. Surgical excision of the tumor and anastomosis of bilateral hepatic ducts and jejunum were carried out. At microscopic examination intraparietal neurofibroma of the common bile duct was found. As isolated entity, we know of only one reported case. PMID:8731581

  7. Device for Measuring Low Flow Speed in a Duct

    NASA Technical Reports Server (NTRS)

    Quinn, Frank; Magee, Kevin

    2009-01-01

    A multiple-throat venturi system has been invented for measuring laminar flow of air or other gas at low speed (1 to 30 cm/s) in a duct while preserving the laminar nature of the flow and keeping the velocity profile across the duct as nearly flat as possible. While means for measuring flows at higher speeds are well established, heretofore, there have been no reliable means for making consistent, accurate measurements in this speed range. In the original application for which this system was invented, the duct leads into the test section of a low-speed wind tunnel wherein uniform, low-speed, laminar flow is required for scientific experiments. The system could also be used to monitor a slow flow of gas in an industrial process like chemical vapor deposition. In the original application, the multiple- throat venturi system is mounted at the inlet end of the duct having a rectangular cross section of 19 by 14 cm, just upstream of an assembly of inlet screens and flow straighteners that help to suppress undesired flow fluctuations (see Figure 1). The basic venturi measurement principle is well established: One measures the difference in pressure between (1) a point just outside the inlet, where the pressure is highest and the kinetic energy lowest; and (2) the narrowest part (the throat) of the venturi passage, where the kinetic energy is highest and the pressure is lowest. Then by use of Bernoulli s equation for the relationship between pressure and kinetic energy, the volumetric flow speed in the duct can be calculated from the pressure difference and the inlet and throat widths. The design of this system represents a compromise among length, pressure recovery, uniformity of flow, and complexity of assembly. Traditionally, venturis are used to measure faster flows in narrower cross sections, with longer upstream and downstream passages to maintain accuracy. The dimensions of the passages of the present venturi system are sized to provide a readily measurable

  8. Evaporation duct communication: Test plan, part 2

    NASA Astrophysics Data System (ADS)

    Anderson, K. D.; Rogers, L. T.

    1991-11-01

    This document is a continuation and expansion of an earlier study that examines the feasibility of using the evaporation duct to support an alternative high-speed communication system for Navy applications. This Evaporation Duct Communication (EDCOM) experiment is a unique opportunity to evaluate another communication channel that can alleviate Navy ship-to-ship communication problems. Therefore, it is strongly recommended to proceed with this measurement program.

  9. Mucoepidermoid carcinoma in a thyroglossal duct remnant

    PubMed Central

    Warner, E.; Ofo, E.; Connor, S.; Odell, E.; Jeannon, J.P.

    2015-01-01

    Introduction Thyroglossal duct cysts (TDC) are common midline neck swellings resulting from embryological remnants of the thyroglossal duct. They often contain ectopic thyroid tissue and malignant transformation has been reported, most commonly to papillary thyroid carcinoma. Mucoepidermoid carcinoma (MEC) usually occurs in the salivary glands and only rarely in the thyroid. This is the first case of a MEC occurring within a thyroglossal duct remnant. Presentation of a case A 73 year old lady presented with a thyroglossal duct cyst. She declined surgical excision, as she was adamant she wanted to avoid surgery. The neck mass rapidly enlarged at two years following initial diagnosis. Fine needle aspiration cytology was suspicious for carcinoma. She underwent total thyroidectomy and selective central compartment neck dissection with adjuvant radiotherapy. She remains alive and well two years post treatment. Discussion Mucoepidermoid carcinoma is the most common malignant neoplasm of salivary glands, although it has rarely been reported in diverse locations including the thyroid, lung and pancreas. To the best of our knowledge, this is the first reported case of mucoepidermoid carcinoma arising from a thyroglossal duct remnant. Conclusion This case adds weight to the literature favouring surgical excision of thyroglossal duct remnants due to the risk of malignant transformation. PMID:26101054

  10. Field comparison of design and diagnostic pathways for duct efficiency evaluation

    SciTech Connect

    Andrews, J.W.

    1996-08-01

    A new method of test for residential thermal distribution efficiency is currently being developed under the auspices of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). This test method will have three main approaches, or ``pathways``, designated Design, Diagnostic, and Research. The Design Pathway uses builder`s information to predict thermal distribution efficiency in new construction. The Diagnostic Pathway uses air-flow, temperature, and pressure-difference tests--intended to take one to four hours--to evaluate thermal distribution efficiency in a completed house. For forced-air systems, three distinct techniques are being considered, one based on thermal inputs and outputs in the duct system, the second based on pressure and leakage-area measurements, and the third based on pressure differentials induced in the house by partial blockage of the return duct. This paper presents and discusses the results of Design Pathway calculations based on measured duct-system and floor-plan layouts and surface areas (in lieu of building plans) for fifteen residential duct systems in Long Island, New York. These are compared with measured Diagnostic Pathway efficiencies in eight of these homes.

  11. Fundamental investigation of duct/ESP phenomena: Flow visualization

    NASA Astrophysics Data System (ADS)

    Brown, C. T.; Sowa, W. A.; Samuelsen, G. S.

    1990-11-01

    The objective is to characterize the performance and behavior of twin-fluid atomizers used for in-duct sulfur capture. Such atomizers characteristically produce dense sprays featuring very narrow dispersion angles and high droplet velocities. To meet the objective, several tasks were identified (1) demonstrate the usefulness of phase Doppler interferometry to characterize humidification atomizers, (2) screen several commercially available atomizers to guide in the selection of nozzles used of field testing, and (3) develop a data base useful for computational code development and validation. The approach taken is to characterize the liquid phase produced by practical, full scale, twin-fluid humidification atomizers. Eight such twin-fluid atomizers are considered. Several of these atomizers were used in field tests. Only water sprays are considered. Atomizer responses to changes in air pressure (air flow rate) and water pressure (water flow rate) are examined. Measurements of droplet size and corresponding mean axial velocity are obtained.

  12. Positive direct current corona discharges in single wire-duct electrostatic precipitators

    NASA Astrophysics Data System (ADS)

    Yehia, Ashraf; Abdel-Fattah, E.; Mizuno, Akira

    2016-05-01

    This paper is aimed to study the characteristics of the positive dc corona discharges in single wire-duct electrostatic precipitators. Therefore, the corona discharges were formed inside dry air fed single wire-duct reactor under positive dc voltage at the normal atmospheric conditions. The corona current-voltage characteristics curves have been measured in parallel with the ozone concentration generated inside the reactor under different discharge conditions. The corona current-voltage characteristics curves have agreed with a semi empirical equation derived from the previous studies. The experimental results of the ozone concentration generated inside the reactor were formulated in the form of an empirical equation included the different parameters that were studied experimentally. The obtained equations are valid to expect both the current-voltage characteristics curves and the corresponding ozone concentration that generates with the positive dc corona discharges inside single wire-duct electrostatic precipitators under any operating conditions in the same range of the present study.

  13. Analysis and consequences of fire inside the ventilation ducts of a nuclear facility

    SciTech Connect

    Briand, A.R.; Laborde, J.C. ); Savornin, J.H.; Tessier, J.L. )

    1989-01-01

    Accident events involving fire are rather frequent and could have a severe effect on the safety of nuclear facilities. Among the fires that have broken out in nuclear plants, several have resulted from ignition of dust deposited inside the ventilation ducts and on the high-efficiency particulate air (HEPA) filters. The BEATRICE test facility has been designed and built at a French nuclear studies center to enable the analysis and consequences of these types of fires to be evaluated. The associated experimental program is aimed at characterizing the fire (fire spread, aerosols formed), determining and simulating the temperature profiles along the duct (thermal losses evaluation by the pipette code), and evaluating the challenge and behavior of the associated HEPA filters (efficiency, contamination release, etc.). The tests performed in this study contributed to improvements in the basic knowledge about fires inside ventilation ducts and define the associated strategies (ventilation control, filters protection, etc.).

  14. Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

    SciTech Connect

    Coles, Henry C.; Han, Taewon; Price, Phillip N.; Gadgil, Ashok J.; Tschudi, William F.

    2011-07-17

    There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical

  15. Technology Solutions Case Study: Sealed Air-Return Plenum Retrofit

    SciTech Connect

    none,

    2012-08-01

    In this project, Pacific Northwest National Laboratory researchers greatly improved indoor air quality and HVAC performance by replacing an old, leaky air handler with a new air handler with an air-sealed return plenum with filter; they also sealed the ducts, and added a fresh air intake.

  16. Interpretation of borehole geophysical logs, aquifer-isolation tests, and water quality, supply wells 1 and 2, Willow Grove Naval Air Station/Joint Reserve Base, Horsham Township, Montgomery County, Pennsylvania

    USGS Publications Warehouse

    Sloto, Ronald A.; Goode, Daniel J.; Frasch, Steven M.

    2002-01-01

    Ground water pumped from supply wells 1 and 2 on the Willow Grove Naval Air Station/Joint Reserve Base (NAS/JRB) provides water for use at the base, including potable water for drinking. The supply wells have been contaminated by volatile organic compounds (VOC?s), particularly trichloroethylene (TCE) and tetrachloroethylene (PCE), and the water is treated to remove the VOC?s. The Willow Grove NAS/JRB and surrounding area are underlain by sedimentary rocks of the Triassic-age Stockton Formation, which form a complex, heterogeneous aquifer. The ground-water-flow system for the supply wells was characterized by use of borehole geophysical logs and heatpulse-flowmeter measurements. The heatpulse-flowmeter measurements showed upward and downward borehole flow under nonpumping conditions in both wells. The hydraulic and chemical properties of discrete water-bearing fractures in the supply wells were characterized by isolating each water-bearing fracture with straddle packers. Eight fractures in supply well 1 and five fractures in supply well 2 were selected for testing on the basis of the borehole geophysical logs and borehole television surveys. Water samples were collected from each isolated fracture and analyzed for VOC?s and inorganic constituents. Fractures at 50?59, 79?80, 196, 124?152, 182, 241, 256, and 350?354 ft btoc (feet below top of casing) were isolated in supply well 1. Specific capacities ranged from 0.26 to 5.7 (gal/min)/ft (gallons per minute per foot) of drawdown. The highest specific capacity was for the fracture isolated at 179.8?188 ft btoc. Specific capacity and depth of fracture were not related in either supply well. The highest concentrations of PCE were in water samples collected from fractures isolated at 236.8?245 and 249.8?258 ft btoc, which are hydraulically connected. The concentration of PCE generally increased with depth to a maximum of 39 mg/L (micrograms per liter) at a depth of 249.8? 258 ft btoc and then decreased to 21 mg/L at a

  17. Investigation of Aerodynamic and Icing Characteristics of a Flush Alternate Inlet Induction System Air Scoop

    NASA Technical Reports Server (NTRS)

    Lewis, James P.

    1953-01-01

    An investigation has been made in the NACA Lewis icing research tunnel to determine the aerodynamic and icing characteristics of a full-scale induction-system air-scoop assembly incorporating a flush alternate inlet. The flush inlet was located immediately downstream of the offset ram inlet and included a 180 deg reversal and a 90 deg elbow in the ducting between inlet and carburetor top deck. The model also had a preheat-air inlet. The investigation was made over a range of mass-air- flow ratios of 0 to 0.8, angles of attack of 0 and 4 deg airspeeds of 150 to 270 miles per hour, air temperatures of 0 and 25 F various liquid-water contents, and droplet sizes. The ram inlet gave good pressure recovery in both clear air and icing but rapid blockage of the top-deck screen occurred during icing. The flush alternate inlet had poor pressure recovery in both clear air and icing. The greatest decreases in the alternate-inlet pressure recovery were obtained at icing conditions of low air temperature and high liquid-water content. No serious screen icing was observed with the alternate inlet. Pressure and temperature distributions on the carburetor top deck were determined using the preheat-air supply with the preheat- and alternate-inlet doors in various positions. No screen icing occurred when the preheat-air system was operated in combination with alternate-inlet air flow.

  18. Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome

    NASA Technical Reports Server (NTRS)

    Ahearn, D. G.; Crow, S. A.; Simmons, R. B.; Price, D. L.; Noble, J. A.; Mishra, S. K.; Pierson, D. L.

    1996-01-01

    Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

  19. Effect of radiant barriers and attic ventilation on residential attics and attic duct systems: New tools for measuring and modeling

    SciTech Connect

    Petrie, T.W.; Childs, P.W.; Christian, J.E.; Wilkes, K.E.

    1998-07-01

    A simple duct system was installed in an attic test module for a large scale climate simulator at a US national laboratory. The goal of the tests and subsequent modeling was to develop an accurate method of assessing duct system performance in the laboratory, enabling limiting conditions to be imposed at will and results to be applied to residential attics with attic duct systems. Steady-state tests were done at a severe summer and a mild winter condition. In all tests the roof surface was heated above ambient air temperatures by infrared lights. The attic test module first included then did not include the duct system. Attic ventilation from eave vents to a ridge vent was varied from none to values achievable by a high level of power ventilation. A radiant barrier was attached to the underside of the roof deck, both with and without the duct system in place. Tests were also done without the radiant barrier, both with and without the duct system. When installed, the insulated ducts ran along the floor of the attic, just above the attic insulation and along the edge of the attic near the eaves and one gable. These tests in a climate simulator achieved careful control and reproducibility of conditions. This elucidated dependencies that would otherwise be hidden by variations in uncontrolled variables. Based on the comparisons with the results of the tests at the mild winter condition and the severe summer condition, model predictions for attic air and insulation temperatures should be accurate within {+-} 10 F ({+-} 6 C). This is judged adequate for design purposes and could be better when exploring the effect of changes in attic and duct parameters at fixed climatic conditions.

  20. Nursing Supplies

    MedlinePlus

    ... Stages Listen Español Text Size Email Print Share Nursing Supplies Page Content Article Body Throughout most of ... budget. (Nursing equipment also makes wonderful baby gifts.) Nursing Bras A well-made nursing bra that comfortably ...

  1. Size limitations in semicircular duct systems

    PubMed

    Muller

    1999-06-01

    The present article discusses mechanical requirements and limitations which are applicable to the construction of the system of semicircular ducts, especially to its size. The simplified case of a single, uniform duct system has been considered which can be described by a second order equation of motion. The principal functional quantities for this rotation-sensor are: (1) response speed; (2) sensitivity; and (3) regular flow. The response speed of a single, uniform semicircular duct is characterized by the short time constant (T2) which is dependent on the duct radius (r). Its estimated range is from 0.04 ms in the smallest to 140 ms in the largest known labyrinth. The sensitivity is characterized by the maximal endolymph displacement after a step stimulus (xmax). Its estimated range is from 0.0016 &mgr;m to 5.97 mm (6.56 decades!), assuming an input angular velocity of omega=1 rad s-1. The Reynolds number is a measure for an undisturbed laminar flow. Its estimated range varies from 7.38.10(-4)to 45.1 for omega=1 rad s-1. The above data follow from graphs in which, for a single uniform duct, circuit radius (R) is plotted against duct radius (r) for labyrinths of 233 species belonging to different vertebrate-groups. A relation R =38.9. r1.60was determined. The smallest labyrinth was found in a carp larva (Cyprinus), the largest in a whale shark (Rhincodon). Large whales possess labyrinths of average mammalian size. It is revealed that semicircular duct size is bound by requirements concerning regular flow and by a too low response speed for large labyrinths, and by a too low sensitivity for small labyrinths. Other important quantities are mechanical amplification factors which are a consequence of more complex vestibular constructions than a single uniform duct circuit. Allometric relationships are interpreted as compromises between the quantities mentioned. A hypothesis for the relatively large semicircular duct sizes of fishes, especially Elasmobranchii, compared

  2. Power Supply

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Maxwell Laboratories capacitor charging power supply is the first commercial spinoff from the NASA CCDS program - a consortia of industries and government establishments to accelerate development of ground and space based commercial applications of NASA technology. The power supply transforms and conditions large voltages to charge capacitors used in x-ray sources, medical accelerators, etc. It is lighter, more reliable, more compact and efficient. Originally developed for space lasers, its commercial potential was soon recognized.

  3. Remodeling of the Fetal Collecting Duct Epithelium

    PubMed Central

    Hiatt, Michael J.; Ivanova, Larissa; Toran, Nuria; Tarantal, Alice F.; Matsell, Douglas G.

    2010-01-01

    Congenital urinary tract obstruction induces changes to the renal collecting duct epithelium, including alteration and depletion of intercalated cells. To study the effects of obstruction on the ontogeny of intercalated cell development, we examined normal and obstructed human fetal and postnatal kidneys. In the normal human fetal kidney, intercalated cells originated in the medullary collecting duct at 8 weeks gestation and remained most abundant in the inner medulla throughout gestation. In the cortex, intercalated cells were rare at 18 and 26 weeks gestation and observed at low abundance at 36 weeks gestation. Although early intercalated cells exhibit an immature phenotype, Type A intercalated cells predominated in the inner and outer medullae at 26 and 36 weeks gestation with other intercalated cell subtypes observed rarely. Postnatally, the collecting duct epithelium underwent a remodeling whereby intercalated cells become abundant in the cortex yet absent from the inner medulla. In 18-week obstructed kidneys with mild to moderate injury, the intercalated cells became more abundant and differentiated than the equivalent age-matched normal kidney. In contrast, more severely injured ducts of the late obstructed kidney exhibited a significant reduction in intercalated cells. These studies characterize the normal ontogeny of human intercalated cell development and suggest that obstruction induces premature remodeling and differentiation of the fetal collecting duct epithelium. PMID:20035053

  4. Convolution seal for transition duct in turbine system

    SciTech Connect

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2015-05-26

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface feature for interfacing with an adjacent transition duct. The turbine system further includes a convolution seal contacting the interface feature to provide a seal between the interface feature and the adjacent transition duct.

  5. Thermal environmental case study of an existing underfloor air distribution (UFAD) system in a high-rise building in the tropics

    NASA Astrophysics Data System (ADS)

    Ya, Y. H.; Poh, K. S.

    2015-09-01

    The performance of an existing underfloor air distribution (UFAD) system in a renowned high-rise office tower in Malaysia was studied to identify the root cause issues behind the poor indoor air quality. Occupants are the best thermal sensor. The building was detected with the sick building syndrome (SBS) that causes runny noses, flu-like symptoms, irritated skin, and etc. Long period of exposure to indoor air pollutants may increase the occupant's health risk. The parameters such as the space temperature, relative humidity, air movement, air change, fresh air flow rate, chilled water supply and return are evaluated at three stories that consist of five open offices. A full traverse study was carried out at one of the fresh air duct. A simplified duct flow measurement method using pitot-tubes was developed. The results showed that the diffusers were not effective in creating the swirl effect to the space. Internal heat gain from human and office electrical equipment were not drawn out effectively. Besides, relative humidity has exceeded the recommended level. These issues were caused by the poor maintenance of the building. The energy efficiency strategy of the UFAD system comes from the higher supply air temperature. It may leads to insufficient cooling load for the latent heat gained under improper system performance. Special care and considerations in design, construction and maintenance are needed to ensure the indoor air quality to be maintained. Several improvements were recommended to tackle the existing indoor air quality issues. Solar system was studied as one of the innovative method for retrofitting.

  6. Energy effectiveness of duct sealing and insulation in two multifamily buildings

    SciTech Connect

    Walker, I.S.; Modera, M.P.; Tuluca, A.; Graham, I. |

    1996-08-01

    Energy losses from forced air distribution systems have a significant impact on the energy efficiency of buildings. Little work has been done to quantify these losses in apartment buildings. In this paper the authors will discuss field measurements made on four forced air heating systems to evaluate the duct system energy losses to unconditioned basements. The apartments were heated by natural gas furnaces located in the basements. The systems had bare sheet metal ductwork exposed to the basement conditions. The pre-retrofit measurements were made on the systems after sealing large easily visible leaks. The post-retrofit measurements were made after wrapping the ducts in foil backed glass fiber insulation and additional leak sealing. Only the sections of duct exposed to the basement were retrofitted because only these sections were accessible. This study examines the potential energy savings for this type of limited retrofit. The energy losses were separated into leakage and conduction terms. Leakage measurements were made using register flowhood techniques. Conduction losses were estimated by measuring temperatures in the plenums and at the registers. Analysis of the measurements has shown typical reduction in leakage flow due to duct sealing of about 40%. The reduction in leakage translated into a reduction in energy consumption of about 10%.

  7. Plants Clean Air and Water for Indoor Environments

    NASA Technical Reports Server (NTRS)

    2007-01-01

    Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

  8. User's Manual for DuctE3D: A Program for 3D Euler Unsteady Aerodynamic and Aeroelastic Analysis of Ducted Fans

    NASA Technical Reports Server (NTRS)

    Srivastava, R.; Reddy, T. S. R.

    1997-01-01

    The program DuctE3D is used for steady or unsteady aerodynamic and aeroelastic analysis of ducted fans. This guide describes the input data required and the output files generated, in using DuctE3D. The analysis solves three dimensional unsteady, compressible Euler equations to obtain the aerodynamic forces. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either the time domain or the frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis and aeroelastic analysis of an isolated fan row.

  9. "Mustache sign" due to Stensen duct dilation.

    PubMed

    Yoruk, O; Kılıc, K; Kantarcı, M

    2013-12-01

    An 80-year-old woman presented with a 5-year history of painless swellings of the left and right cheeks. The degree of swelling did not change with mastication. On palpation, the cheeks were soft, well defined, and movable. Compression and massage of the swollen areas caused increased salivary discharge from the orifices of the Stensen ducts. Three-dimensional computed tomography showed well-bordered, 15- to 20-mm wide, bilateral, tube-like dilatations of the ducts. The ductal origin of the swellings was explained to the patient, but she refused invasive procedures, thus no sialogram or surgical procedure was performed. We describe the clinical and radiographic features of a case of bilateral, congenital Stensen duct dilatation with bilateral swelling of the cheeks. PMID:24209996

  10. Acoustic energy in ducts - Further observations

    NASA Technical Reports Server (NTRS)

    Eversman, W.

    1979-01-01

    The transmission of acoustic energy in uniform ducts carrying uniform flow is investigated with the purpose of clarifying two points of interest. The two commonly used definitions of acoustic 'energy' flux are shown to be related by a Legendre transformation of the Lagrangian density exactly as in deriving the Hamiltonian density in mechanics. In the acoustic case the total energy density and the Hamiltonian density are not the same which accounts for two different 'energy' fluxes. When the duct has acoustically absorptive walls neither of the two flux expressions gives correct results. A reevaluation of the basis of derivation of the energy density and energy flux provides forms which yield consistent results for soft walled ducts.

  11. Modeling of three-dimensional mixing and reacting ducted flows

    NASA Technical Reports Server (NTRS)

    Zelazny, S. W.; Baker, A. J.; Rushmore, W. L.

    1976-01-01

    A computer code, based upon a finite element solution algorithm, was developed to solve the governing equations for three-dimensional, reacting boundary region, and constant area ducted flow fields. Effective diffusion coefficients are employed to allow analyses of turbulent, transitional or laminar flows. The code was used to investigate mixing and reacting hydrogen jets injected from multiple orifices, transverse and parallel to a supersonic air stream. Computational results provide a three-dimensional description of velocity, temperature, and species-concentration fields downstream of injection. Experimental data for eight cases covering different injection conditions and geometries were modeled using mixing length theory (MLT). These results were used as a baseline for examining the relative merits of other mixing models. Calculations were made using a two-equation turbulence model (k+d) and comparisons were made between experiment and mixing length theory predictions. The k+d model shows only a slight improvement in predictive capability over MLT. Results of an examination of the effect of tensorial transport coefficients on mass and momentum field distribution are also presented. Solutions demonstrating the ability of the code to model ducted flows and parallel strut injection are presented and discussed.

  12. Computing Propagation Of Sound In Engine Ducts

    NASA Technical Reports Server (NTRS)

    Saylor, Silvia

    1995-01-01

    Frequency Domain Propagation Model (FREDOM) computer program accounts for acoustic loads applied to components of engines. Models propagation of noise through fluids in ducts between components and through passages within components. Used not only to analyze hardware problems, but also for design purposes. Updated version of FREQPL program easier to use. Devised specifically for use in analyzing acoustic loads in rocket engines. Underlying physical and mathematical concepts implemented also applicable to acoustic propagation in other enclosed spaces; analyzing process plumbing and ducts in industrial buildings with view toward reducing noise in work areas.

  13. Modern management of common bile duct stones.

    PubMed

    Buxbaum, James

    2013-04-01

    It is imperative for gastroenterologists to understand the different formations of bile duct stones and the various medical treatments available. To minimize the complications of endoscopic retrograde cholangiopancreatography (ERCP), it is critical to appropriately assess the risk of bile duct stones before intervention. Biliary endoscopists should be comfortable with the basic techniques of stone removal, including sphincterotomy, mechanical lithotripsy, and stent placement. It is important to be aware of advanced options, including laser and electrohydraulic stone fragmentation, and papillary dilatation for problematic cases. The timing and need for ERCP in those who require a cholecystectomy is also a consideration. PMID:23540960

  14. Fundamental investigation of duct/ESP phenomena

    SciTech Connect

    Brown, C.A. ); Durham, M.D. ); Sowa, W.A. . Combustion Lab.); Himes, R.M. ); Mahaffey, W.A. )

    1991-10-21

    Radian Corporation was contracted to investigate duct injection and ESP phenomena in a 1.7 MW pilot plant constructed for this test program. This study was an attempt to resolve problems found in previous studies and answer remaining questions for the technology using an approach which concentrates on the fundamental mechanisms of the process. The goal of the study was to obtain a better understanding of the basic physical and chemical phenomena that control: (1) the desulfurization of flue gas by calcium-based reagent, and (2) the coupling of an existing ESP particulate collection device to the duct injection process. Process economics are being studied by others. (VC)

  15. Preconditioning the Helmholtz Equation for Rigid Ducts

    NASA Technical Reports Server (NTRS)

    Baumeister, Kenneth J.; Kreider, Kevin L.

    1998-01-01

    An innovative hyperbolic preconditioning technique is developed for the numerical solution of the Helmholtz equation which governs acoustic propagation in ducts. Two pseudo-time parameters are used to produce an explicit iterative finite difference scheme. This scheme eliminates the large matrix storage requirements normally associated with numerical solutions to the Helmholtz equation. The solution procedure is very fast when compared to other transient and steady methods. Optimization and an error analysis of the preconditioning factors are present. For validation, the method is applied to sound propagation in a 2D semi-infinite hard wall duct.

  16. Congenital Atresia of Wharton’s Duct

    PubMed Central

    Hseu, Anne; Anne, Premchand

    2016-01-01

    This is a case report of a three-month-old male who presented to clinic with a cystic lesion under the tongue. On clinical examination, a cystic lesion was observed in the, floor-of-mouth. The patient was referred to Paediatric Otorhinolaryngology service for further management. The differential diagnoses for floor-of-mouth lesions should be reviewed with primary focus on the Wharton’s duct atresia and its management. It is crucial to recognize submandibular duct atresia in the primary Paediatric clinic in order to expedite management of lesion before complications arise including infection, enlargement of cyst, and feeding and breathing difficulties. PMID:27042492

  17. Liquid-Air Breathing Apparatus

    NASA Technical Reports Server (NTRS)

    Mills, Robert D.

    1990-01-01

    Compact unit supplies air longer than compressed-air unit. Emergency breathing apparatus stores air as cryogenic liquid instead of usual compressed gas. Intended for firefighting or rescue operations becoming necessary during planned potentially hazardous procedures.

  18. Air Cooling for High Temperature Power Electronics (Presentation)

    SciTech Connect

    Waye, S.; Musselman, M.; King, C.

    2014-09-01

    Current emphasis on developing high-temperature power electronics, including wide-bandgap materials such as silicon carbide and gallium nitride, increases the opportunity for a completely air-cooled inverter at higher powers. This removes the liquid cooling system for the inverter, saving weight and volume on the liquid-to-air heat exchanger, coolant lines, pumps, and coolant, replacing them with just a fan and air supply ducting. We investigate the potential for an air-cooled heat exchanger from a component and systems-level approach to meet specific power and power density targets. A proposed baseline air-cooled heat exchanger design that does not meet those targets was optimized using a parametric computational fluid dynamics analysis, examining the effects of heat exchanger geometry and device location, fixing the device heat dissipation and maximum junction temperature. The CFD results were extrapolated to a full inverter, including casing, capacitor, bus bar, gate driver, and control board component weights and volumes. Surrogate ducting was tested to understand the pressure drop and subsequent system parasitic load. Geometries that met targets with acceptable loads on the system were down-selected for experimentation. Nine baseline configuration modules dissipated the target heat dissipation, but fell below specific power and power density targets. Six optimized configuration modules dissipated the target heat load, exceeding the specific power and power density targets. By maintaining the same 175 degrees C maximum junction temperature, an optimized heat exchanger design and higher device heat fluxes allowed a reduction in the number of modules required, increasing specific power and power density while still maintaining the inverter power.

  19. What Should You Ask Your Doctor about Bile Duct Cancer?

    MedlinePlus

    ... treatment for bile duct cancer? What should you ask your doctor about bile duct cancer? It is ... your own. For instance, you might want to ask about clinical trials for which you may qualify. ...

  20. Experimental evaluation of a pilot multinozzle-duct apparatus

    NASA Technical Reports Server (NTRS)

    Puster, R. L.

    1979-01-01

    A pilot multinozzle and duct were tested at ambient enthalpy to evaluate the suitability of such apparatus for testing thermal protection system panels mounted in the sidewalls of the duct downstream of the nozzle array. The flow field in the duct was complex: effects of wakes and shock waves from the nozzle dominated the flow field; the wakes continually mixed with the surrounding fluid; the boundary layer on the sidewalls of the duct was nonuniform; and near the exit of the duct the sidewall pressure variation was as much as 8.5 percent about the mean wall pressure. Starting loads on the duct walls were higher than those of a similar conventional nozzle and duct. It was concluded that the multinozzle-duct apparatus was not suitable for testing TPS panels, although the design and flow-field information should be of interest to designers of high-energy gasdynamic lasers.

  1. Direct numerical simulation of turbulence and heat transfer in a hexagonal shaped duct

    NASA Astrophysics Data System (ADS)

    Marin, Oana; Obabko, Aleks; Schlatter, Philipp

    2014-11-01

    Flows in hexagonal shapes frequently occur in nuclear reactor applications, and are also present in honeycomb-shaped settling chambers for e.g. wind tunnels. Whereas wall-bounded turbulence has been studied comprehensively in two-dimensional channels, and to a lesser degree also in square and rectangular ducts and triangles, only very limited data for hexagonal ducts is available, including resistance correlations and mean profiles. Here, we use resolved spectral-element simulations to compute velocity and temperature in fully-developed (periodic) hexagonal duct flow. The Reynolds number, based on the fixed flow rate and the hydraulic diameter, ranges between 2000 and 20000. The temperature assumes constant wall flux or constant wall temperature. First DNS results are focused on the mean characteristics such a head loss, Nusselt number, and critical Reynolds number for sustained turbulence. Profiles, both for mean and fluctuating quantities, are extracted and discussed in the context of square ducts and pipes. Comparisons to existing experiments, RANS and empirical correlations are supplied as well. The results show a complicated and fine-scale pattern of the in-plane secondary flow, which clearly affects the momentum and temperature distribution throughout the cross section.

  2. In-duct identification of fluid-borne source with high spatial resolution

    NASA Astrophysics Data System (ADS)

    Heo, Yong-Ho; Ih, Jeong-Guon; Bodén, Hans

    2014-11-01

    Source identification of acoustic characteristics of in-duct fluid machinery is required for coping with the fluid-borne noise. By knowing the acoustic pressure and particle velocity field at the source plane in detail, the sound generation mechanism of a fluid machine can be understood. The identified spatial distribution of the strength of major radiators would be useful for the low noise design. Conventional methods for measuring the source in a wide duct have not been very helpful in investigating the source properties in detail because their spatial resolution is improper for the design purpose. In this work, an inverse method to estimate the source parameters with a high spatial resolution is studied. The theoretical formulation including the evanescent modes and near-field measurement data is given for a wide duct. After validating the proposed method to a duct excited by an acoustic driver, an experiment on a duct system driven by an air blower is conducted in the presence of flow. A convergence test for the evanescent modes is performed to find the necessary number of modes to regenerate the measured pressure field precisely. By using the converged modal amplitudes, very-close near-field pressure to the source is regenerated and compared with the measured pressure, and the maximum error was -16.3 dB. The source parameters are restored from the converged modal amplitudes. Then, the distribution of source parameters on the driver and the blower is clearly revealed with a high spatial resolution for kR<1.84 in which range only plane waves can propagate to far field in a duct. Measurement using a flush mounted sensor array is discussed, and the removal of pure radial modes in the modeling is suggested.

  3. Cold air systems: Sleeping giant

    SciTech Connect

    MacCracken, C.D. )

    1994-04-01

    This article describes how cold air systems help owners increase the profits from their buildings by reducing electric costs and improving indoor air quality through lower relative humidity levels. Cold air distribution involves energy savings, cost savings, space savings, greater comfort, cleaner air, thermal storage, tighter ducting, coil redesign, lower relative humidities, retrofitting, and improved indoor air quality (IAQ). It opens a door for architects, engineers, owners, builders, environmentalists, retrofitters, designers, occupants, and manufacturers. Three things have held up cold air's usage: multiple fan-powered boxes that ate up the energy savings of primary fans. Cold air room diffusers that provided inadequate comfort. Condensation from ducts, boxes, and diffusers. Such problems have been largely eliminated through research and development by utilities and manufacturers. New cold air diffusers no longer need fan powered boxes. It has also been found that condensation is not a concern so long as the ducts are located in air conditioned space, such as drop ceilings or central risers, where relative humidity falls quickly during morning startup.

  4. The refractive propagation factor and the rough evaporation duct experiment

    NASA Astrophysics Data System (ADS)

    Doss-Hammel, Stephen M.; Tsintikidis, Dimitris; Davidson, Kenneth L.; Frederickson, Paul A.

    2003-03-01

    The Rough Evaporation Duct Experiment (RED) assessed the effects of the air-sea boundary layer on microwave and infrared (IR) signal propagation near the sea surface. The experiment was designed around the Floating Instrument Platform (FLIP) research platform, which was moored 10 kilometers off the northeast shore of Oahu, Hawaii. A 10-kilometer infrared propagation path was created from FLIP to a shore-based receiver and both scintillation and transmission measurements were made around the clock for a two-week period. An accurate model for the propagation of infrared signals in the marine atmospheric surface layer remains an elusive goal. Within the first tens of meters of elevation above the sea surface there are substantial vertical gradients of mass and temperature, and this has a strong effect on the prediction of extinction of the infrared signal. The effectiveness of the propagation models will be investigated and the results from the infrared signal propagation study during RED will be shown.

  5. Ducted Fan Designs Lead to Potential New Vehicles

    NASA Technical Reports Server (NTRS)

    2010-01-01

    In 1994, aerospace engineers Rob Bulaga and Mike Moshier formed Trek Aerospace Inc., based in Folsom, California, to develop personal air vehicles using a novel ducted fan design. The company relied on Ames Research Center for a great deal of testing, the results of which have provided greater lift, lowered weight, more power, and improved maneuverability. The technology has been applied to three models: the Dragonfly UMR-1, the Springtail EFV, and the OVIWUN, a small-scale version that is for sale through the company's Web site. It is safer than a manned vehicle, and its size makes it relatively difficult for it to damage itself during test flights the way a larger mass, faster craft could.

  6. Minimum airflow reset of single-duct VAV terminal boxes

    NASA Astrophysics Data System (ADS)

    Cho, Young-Hum

    Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and

  7. Numerical Simulation of Noise from Supersonic Jets Passing Through a Rigid Duct

    NASA Technical Reports Server (NTRS)

    Kandula, Max

    2012-01-01

    The generation, propagation and radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet flowing through an enclosed rigid-walled duct with an upstream J-deflector have been numerically simulated with the aid of OVERFLOW Navier-Stokes CFD code. A one-equation turbulence model is considered. While the near-field sound sources are computed by the CFD code, the far-field sound is evaluated by Kirchhoff surface integral formulation. Predictions of the farfield directivity of the OASPL (Overall Sound Pressure Level) agree satisfactorily with the experimental data previously reported by the author. Calculations also suggest that there is significant entrainment of air into the duct, with the mass flow rate of entrained air being about three times the jet exit mass flow rate.

  8. Will Duct Tape and Plastic Really Work? Issues Related to Expedient Shelter-In-Place

    SciTech Connect

    Sorensen, J.H.

    2002-08-30

    Expedient sheltering involves the use of common materials to enhance the safety of a room inside a building against the impacts of a chemical plume. The central premise behind taping and sealing with duct tape and plastic is to reduce airflow into a room. This paper reviews issues associated with the use of expedient sheltering materials and the effectiveness of this strategy. Expedient sheltering provides additional protection to people sheltering in place beyond that provided by the house and by a safe room without expedient measures. The materials chosen for taping and sealing--duct tape and plastic--are appropriate because they effectively reduce infiltration and the materials should withstand a vapor challenge. Taping is essential to reduce air infiltration. Plastic sheeting is not a critical element for reducing air infiltration, but it makes sealing off large windows easier.

  9. Power supply

    DOEpatents

    Yakymyshyn, Christopher Paul; Hamilton, Pamela Jane; Brubaker, Michael Allen

    2007-12-04

    A modular, low weight impedance dropping power supply with battery backup is disclosed that can be connected to a high voltage AC source and provide electrical power at a lower voltage. The design can be scaled over a wide range of input voltages and over a wide range of output voltages and delivered power.

  10. Thyroglossal Duct Carcinoma in a Cat.

    PubMed

    Moorer, Jeremiah D; Breshears, Melanie A; Dugat, Danielle R

    2016-01-01

    A 14 yr old castrated domestic shorthair cat presented for a fluid-filled structure in the ventral cervical region that had been present for 1 yr and had not resolved after repeated aspiration and drainage. Cervical computed tomography showed an approximately 10 cm, fluid-filled, multilobulated mass located on the ventrolateral right side of the cervical region extending into the thoracic inlet. Cytologic examination of the fluid revealed cystic fluid with evidence of chronic hemorrhage. The mass was surgically removed, and histopathologic examination revealed a thyroglossal duct carcinoma. Thyroid and parathyroid gland origin were ruled out by negative immunohistochemical staining for thyroglobulin, parathyroid hormone, calcitonin, and synaptophysin. No adjunctive treatment was performed and no recurrence was noted at 14 mo. Thyroglossal duct carcinoma has not been previously reported in a cat. There are two previous reports of squamous cell carcinoma of the thyroglossal duct in dogs. In humans, with complete removal and no evidence of metastasis, carcinoma of the thyroglossal duct has a good prognosis for recovery. PMID:27259027

  11. Idea Bank: Duct Tape Note Twister

    ERIC Educational Resources Information Center

    McHenry, Molly

    2008-01-01

    In this article, the author relates how she observed a middle school math teacher deliver a miserable class. She realized that she did the same thing to her music students. To engage her students, she developed "Note Twister," a music reading game using duct tape to form musical notes and the basic premise behind the game, "Twister." She finds…

  12. Starting flow in regular polygonal ducts

    NASA Astrophysics Data System (ADS)

    Wang, C. Y.

    2016-06-01

    The starting flows in regular polygonal ducts of S = 3, 4, 5, 6, 8 sides are determined by the method of eigenfunction superposition. The necessary S-fold symmetric eigenfunctions and eigenvalues of the Helmholtz equation are found either exactly or by boundary point match. The results show the starting time is governed by the first eigenvalue.

  13. Thoracoscopic Ligation of the Thoracic Duct

    PubMed Central

    Teixeira, Julio A.

    2000-01-01

    Objective: When nonoperative treatment of chylothorax fails, thoracic duct ligation is usually performed through a thoracotomy. We describe two cases of persistent chylothorax, in a child and an adult, successfully treated with thoracoscopic ligation of the thoracic duct. Methods: A 4-year-old girl developed a right chylothorax following a Fontan procedure. Aggressive nonoperative management failed to eliminate the persistent chyle loss. A 72-year-old insulin-dependent diabetic man was involved in a motor vehicle accident, in which he sustained multiple fractured ribs, a right hemopneumothorax, a right femoral shaft fracture, and a T-11 thoracic vertebral fracture. Subsequently, he developed a right chylothorax, which did not respond to nonoperative management. Both patients were successfully treated with thoracoscopic ligation of the thoracic duct. Results: The child had significant decrease of chyle drainage following surgery. Increased drainage that appeared after the introduction of full feedings five days postoperatively was controlled with the somatostatin analog octreotide. The chest tube was removed two weeks after surgery. After two years' follow-up, she has had no recurrence of chylothorax. The adult had no chyle drainage following surgery. He was maintained on a medium-chain triglyceride diet postoperatively for two weeks. The chest tube was removed four days after surgery. After six months' follow-up, he has had no recurrence of chylothorax. Conclusions: Thoracoscopic ligation of the thoracic duct provides a safe and effective treatment of chylothorax and may avoid thoracotomy and its associated morbidity. PMID:10987402

  14. 46 CFR 116.610 - Ventilation ducts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... prevent corrosion; (4) Fire dampers must be capable of manual operation from outside the space served, be... damper, automatic damper, or vent cover, must be provided in an accessible location outside the space... duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary...

  15. 46 CFR 116.610 - Ventilation ducts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... prevent corrosion; (4) Fire dampers must be capable of manual operation from outside the space served, be... damper, automatic damper, or vent cover, must be provided in an accessible location outside the space... duct penetrating an A-Class fire control boundary and opening into a space formed by that boundary...

  16. The Energy Implications of Air-Side Fouling in Constant Air Volume HVAC Systems

    NASA Astrophysics Data System (ADS)

    Wilson, Eric J. H.

    2011-12-01

    This thesis examines the effect of air-side fouling on the energy consumption of constant air volume (CAV) heating, ventilating, and air conditioning (HVAC) systems in residential and small commercial buildings. There is a particular focus on evaluating the potential energy savings that may result from the remediation of such fouling from coils, filters, and other air system components. A computer model was constructed to simulate the behavior of a building and its duct system under various levels of fouling. The model was verified through laboratory and field testing and then used to run parametric simulations to examine the range of energy impacts for various climates and duct system characteristics. A sensitivity analysis was conducted to determine the impact of parameters like duct insulation, duct leakage, duct location, and duct design on savings potential. Duct system pressures, temperatures, and energy consumption for two houses were monitored for one month. The houses' duct systems, which were both in conditioned space, were given a full cleaning, and were then monitored for another month. The flow rates at the houses improved by 10% and 6%. The improvements were primarily due to installing a new filter, as both houses had only light coil fouling. The results indicate that there was negligible change in heating energy efficiency due to the system cleaning. The parametric simulation results are in agreement with the field experiment: for systems in all eight climates, with flowrates degraded by 20% or less, if ducts are located within the thermal zone, HVAC source energy savings from cleaning are negligible or even slightly negative. However, if ducts are outside the thermal zone, savings are in the 1 to 5% range. For systems with flowrates degraded by 40%, if ducts are within the thermal zone, savings from cleaning occurs only for air conditioning energy, up to 8% in climates like Miami, FL. If ducts are outside the thermal zone, savings occurs with both

  17. Turbofan aft duct suppressor study program listing and user's guide

    NASA Technical Reports Server (NTRS)

    Joshi, M. C.; Kraft, R. E.

    1983-01-01

    A description of the structure of the Annular Flow Duct Program (AFDP) for the calculation of acoustic suppression due to treatment in a finite length annular duct carrying sheared flow is presented. Although most appropriate for engine exhaust ducts, this program can be used to study sound propagation in any duct that maintains annular geometry over a considerable length of the duct. The program is based on the modal analysis of sound propagation in ducts with axial segments of different wall impedances. For specified duct geometry, wall impedance, flow and acoustic conditions in the duct (including mode amplitude distribution of the source) and duct termination reflection characteristics, the program calculates the suppression due to the treatment in the duct. The presence of forward and backward traveling modes in the duct due to the reflection and redistribution of modes at segment interfaces and duct end terminations are taken into account in the calculations. The effects of thin wall boundary layers (with a linear or mean flow velocity profile) on the acoustic propagation are also included in the program. A functional description of the major subroutines is included and a sample run is provided with an explanation of the output.

  18. A bidirectional microphone for the measurement of duct noise

    NASA Astrophysics Data System (ADS)

    La Fontaine, R. F.; Shepherd, I. C.; Cabelli, A.

    1985-08-01

    A bidirectional microphone which resolves acoustic plane waves in ducts into forward and backward propagating components is described. The microphone has a flat frequency response and finds applications in the analysis of duct noise and in the determination of reflection coefficients for various duct configurations. It can also be employed as a unidirectional microphone in active noise attenuators.

  19. Aerosol sampling from stacks and ducts at the Rocky Flats Plant

    SciTech Connect

    McFarlane, A.R.; Anand, N.K.; Ortiz, C.A.

    1995-12-31

    While the Rocky Flats Plant (RFP) in Golden, CO is being decommissioned; there is air flow through the ventilation systems in the buildings. Although the air is HEPA filtered, under the requirements of both the U.S. EPA and the U.S. DOE, several of the stacks and ducts must be continuously monitored for radionuclide aerosol particles, where plutonium is the principal radionuclide of concern. The air sampling effort for compliance with EPA requirements is focussed on the acquisition of representative aerosol samples, which are collected on filters and subsequently analyzed in a laboratory. The goal of the DOE sampling is to acquire representative samples that can be analyzed with near-real-time monitors for alarming purposes, where the alarms are used to warn workers that may be affected by elevated concentrations of radionuclides. The air sampling at RFP is based on single point representative sampling with a shrouded probe. For stacks and ducts that are under the cognizance of EPA, the approach is embodied in a set of Alternate Reference Methodologies that EPA has approved for use at DOE facilities. Shrouded probes were designed based on numerical predictions of performance and the efficacy of the probes was verified by wind tunnel tests. Aerosol transport lines were designed using a code, DEPOSITION that provides optimization of aerosol penetration. Adequacy of a location for single point sampling was based on numerical criteria for mixing of both contaminant mass and fluid momentum as manifested by the uniformity of the velocity profile and the profiles of tracer gas and aerosol particles. Scale models were constructed of key ducts and these were tested in the laboratory to determine the proper locations. For ducts and stacks that fall under DOE, but not EPA requirements, similar methodology was used; however, the single point sampling location is based on alarming considerations.

  20. Basement utility room (room 24; air handling room), near the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Basement utility room (room 24; air handling room), near the west end of the combat operations center, looking southwest towards fan system one, air ducts, and walk-in filter rooms. The exterior equipment well is visible at the left - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  1. Duct injection for SO{sub 2} control, Design Handbook, Volume 1, Process design and engineering guidelines

    SciTech Connect

    1995-09-01

    PETC developed a comprehensive program of coal-related, acid-rain research and development with a major activity area centering on flue gas cleanup and control of SO{sub 2} emissions. Particular emphasis was placed on the retrofit measures for older coal-fired power plants which predate the 1971 New Source Performance Standards. Candidate emission control technologies fall into three categories, depending upon their point of application along the fuel path (i.e., pre, during, or post combustion). The post-combustion, in-duct injection of a calcium-based chemical reagent seemed promising. Preliminary studies showed that reagent injection between the existing air heater and electrostatic precipitator (ESP) could remove between 50-60% of the SO{sub 2} and produce an environmentally safe, dry, solid waste that is easily disposed. Although SO{sub 2} removal efficiencies were less, the estimated capital costs for duct injection technology were low making the economics of duct injection systems seem favorable when compared to conventional wet slurry scrubbers under certain circumstances. With the promulgation of the Clean Air Act Amendments of 1990 came more incentive for the development of low capital cost flue gas desulfurization (FGD) processes. A number of technical problems had to be resolved, however, before duct injection technology could be brought to a state of commercial readiness. The Duct Injection Technology Development Program was launched as a comprehensive, four-year research effort undertaken by PETC to develop this new technology. Completed in 1992, this Duct Injection Design Handbook and the three-dimensional predictive mathematical model constitute two primary end products from this development program. The aim of this design handbook and the accompanying math model is to provide utility personnel with sufficient information to evaluate duct injection technology against competing SO{sub 2} emissions reduction strategies for an existing plant.

  2. Experimental testing and computational modeling of flat oval duct deflection

    SciTech Connect

    Smolinski, P.J.; Palmer, G.S.

    1998-10-01

    The deflection characteristics of spiral seam flat oval HVAC duct are examined in this study, and the effects of duct size, wall thickness, and the size spacing, and type of external reinforcement on the duct deformation are investigated. A duct test setup and a deflection measurement frame were developed for measuring the deformation of flat oval duct, and experimental testing was performed on a variety of duct configurations to measure the duct deflections at various positive and negative internal pressures. Finite element computer models of the ducts were developed to predict the deflections. The correlation between the predictions of the computer model and the data from the experimental testing is highly variable with differences ranging from a few percent to several hundred percent. In general, it was found that there was closer agreement between the finite element results and the experimental measurements for smaller duct and at locations of type 2 external reinforcements. This may be due to the fact that the finite element model assumed the idealized flat oval shape and this shape was better matched by smaller ducts and near the external reinforcement. It was also found that in some cases, unreinforced duct could achieve higher pressures than type 1 reinforced duct before exceeding the deflection limits. Sources of error include the uneven surface of the mastic in the measurement of the duct joint deflection and the variance of the actual duct shape from the idealized shape used in the finite element model. This study did not examine the variability of the experimental results due to differences in duct shape or manufacture.

  3. A theoretical study of limit cycle oscillations of plenum air cushions

    NASA Astrophysics Data System (ADS)

    Hinchey, M. J.; Sullivan, P. A.

    1981-11-01

    Air cushion vehicles (ACV) are prone to the occurrence of dynamic instabilities which frequently appear as stable finite amplitude oscillations. The aim of this work is to ascertain if the non-linearities characteristics of ACV dynamics generate limit cycle oscillations for cushion systems operating at conditions for which a linear theory predicts instability. The types of non-linearity that can occur are discussed, and an analysis is presented for a single cell flexible skirted plenum chamber constrained to move in pure heave only. Two cushion feed cases are considered: a plenum box supply and a duct. The results obtained by a Galerkin/describing function analysis are compared with those generated by a full numerical simulation. For the plenum box supply system, it is shown that the limit cycles can be suppressed by using a piston to introduce high frequency small amplitude volume oscillations into the plenum chamber.

  4. Investigation of the Rocket Induced Flow Field in a Rectangular Duct

    NASA Technical Reports Server (NTRS)

    Landrum, D. Brian; Lambert, James; Thames, Mignon; Hawk, Clark

    1999-01-01

    Rocket-Based Combined Cycle (RBCC) concepts attempt to improve the performance of launch vehicles at all points in the launch trajectory and make highly reusable launch vehicles a reality. The Aerojet Strutjet RBCC concept consists of a variable geometry duct with internal, vertical struts that functions in ducted rocket, ramjet, scramjet, and pure rocket modes. These struts have rocket and turbine exhaust nozzles imbedded within them. The rocket flows create an ejector effect with the ingested air at subsonic flight velocities. In ramjet and scramjet modes, the fuel rich nozzle flows react with the ingested air producing an afterburner effect. Under a NASA Marshall Space Flight Center contract, the UAH Propulsion Research Center (PRC) has designed and built a Strutjet simulation facility. A scale model of a single strut has been built and is undergoing cold-flow testing to investigate the mixing of the rocket and turbine exhausts with the ingested air. A complementary experimental program is also underway to examine the induced flow-field generated by rocket nozzles confined in a rectangular duct. Characterizing the induced flow behavior is critical to understanding and optimizing the performance of future Strutjet-based RBCC propulsion systems. The proposed paper will present results from the rocket induced flow investigation.

  5. Performance Study and CFD Predictions of a Ducted Fan System

    NASA Technical Reports Server (NTRS)

    Abrego, Anita I.; Chang, I-Chung; Bulaga, Robert W.; Rutkowski, Michael (Technical Monitor)

    2002-01-01

    An experimental investigation was completed in the NASA Ames 7 by 10-Foot Wind Tunnel to study the performance characteristics of a ducted fan. The goal of this effort is to study the effect of ducted fan geometry and utilize Computational Fluid Dynamics (CFD) analysis to provide a baseline for correlation. A 38-inch diameter, 10-inch chord duct with a five-bladed fixed-pitch fan was tested. Duct performance data were obtained in hover, vertical climb, and forward flight test conditions. This paper will present a description of the test, duct performance results and correlation with CFD predictions.

  6. Transition duct with divided upstream and downstream portions

    SciTech Connect

    McMahan, Kevin Weston; LeBegue, Jeffrey Scott; Maldonado, Jaime Javier; Dillard, Daniel Jackson; Flanagan, James Scott

    2015-07-14

    Turbine systems are provided. In one embodiment, a turbine system includes a transition duct comprising an inlet, an outlet, and a duct passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The duct passage includes an upstream portion extending from the inlet and a downstream portion extending from the outlet. The turbine system further includes a rib extending from an outer surface of the duct passage, the rib dividing the upstream portion and the downstream portion.

  7. Acoustic radiation from lined, unflanged ducts: Acoustic source distribution program

    NASA Technical Reports Server (NTRS)

    Beckemeyer, R. J.; Sawdy, D. T.

    1971-01-01

    An acoustic radiation analysis was developed to predict the far-field characteristics of fan noise radiated from an acoustically lined unflanged duct. This analysis is comprised of three modular digital computer programs which together provide a capability of accounting for the impedance mismatch at the duct exit plane. Admissible duct configurations include circular or annular, with or without an extended centerbody. This variation in duct configurations provides a capability of modeling inlet and fan duct noise radiation. The computer programs are described in detail.

  8. Power supply

    DOEpatents

    Hart, Edward J.; Leeman, James E.; MacDougall, Hugh R.; Marron, John J.; Smith, Calvin C.

    1976-01-01

    An electric power supply employs a striking means to initiate ferroelectric elements which provide electrical energy output which subsequently initiates an explosive charge which initiates a second ferroelectric current generator to deliver current to the coil of a magnetic field current generator, creating a magnetic field around the coil. Continued detonation effects compression of the magnetic field and subsequent generation and delivery of a large output current to appropriate output loads.

  9. Impacts of Rising Air Temperatures and Emissions Mitigation on Electricity Demand and Supply in the United States. A Multi-Model Comparison

    SciTech Connect

    McFarland, James; Zhou, Yuyu; Clarke, Leon; Sullivan, Patrick; Colman, Jesse; Jaglom, Wendy S.; Colley, Michelle; Patel, Pralit; Eom, Jiyon; Kim, Son H.; Kyle, G. Page; Schultz, Peter; Venkatesh, Boddu; Haydel, Juanita; Mack, Charlotte; Creason, Jared

    2015-06-10

    The electric power sector both affects and is affected by climate change. Numerous studies highlight the potential of the power sector to reduce greenhouse gas emissions. Fewer studies have explored the physical impacts of climate change on the power sector. Our present analysis examines how projected rising temperatures affect the demand for and supply of electricity. We apply a common set of temperature projections to three well-known electric sector models in the United States: the US version of the Global Change Assessment Model (GCAM-USA), the Regional Electricity Deployment System model (ReEDS), and the Integrated Planning Model (IPM®). Incorporating the effects of rising temperatures from a control scenario without emission mitigation into the models raises electricity demand by 1.6 to 6.5 % in 2050 with similar changes in emissions. Moreover, the increase in system costs in the reference scenario to meet this additional demand is comparable to the change in system costs associated with decreasing power sector emissions by approximately 50 % in 2050. This result underscores the importance of adequately incorporating the effects of long-run temperature change in climate policy analysis.

  10. Erratum to: Impacts of rising air temperatures and emissions mitigation on electricity demand and supply in the United States: a multi-model comparison

    SciTech Connect

    McFarland, James; Zhou, Yuyu; Clarke, Leon; Sullivan, Patrick; Colman, Jesse; Jaglom, Wendy S.; Colley, Michelle; Patel, Pralit; Eom, Jiyon; Kim, Son H.; Kyle, G. Page; Schultz, Peter; Venkatesh, Boddu; Haydel, Juanita; Mack, Charlotte; Creason, Jared

    2015-07-07

    The electric power sector both affects and is affected by climate change. Numerous studies highlight the potential of the power sector to reduce greenhouse gas emissions. Yet fewer studies have explored the physical impacts of climate change on the power sector. The present analysis examines how projected rising temperatures affect the demand for and supply of electricity. We apply a common set of temperature projections to three well-known electric sector models in the United States: the US version of the Global Change Assessment Model (GCAM-USA), the Regional Electricity Deployment System model (ReEDS), and the Integrated Planning Model (IPM®). Incorporating the effects of rising temperatures from a control scenario without emission mitigation into the models raises electricity demand by 1.6 to 6.5 % in 2050 with similar changes in emissions. The increase in system costs in the reference scenario to meet this additional demand is comparable to the change in system costs associated with decreasing power sector emissions by approximately 50 % in 2050. This result underscores the importance of adequately incorporating the effects of long-run temperature change in climate policy analysis.

  11. Impacts of rising air temperatures and emissions mitigation on electricity demand and supply in the United States: a multi-model comparison

    SciTech Connect

    McFarland, James; Zhou, Yuyu; Clarke, Leon; Sullivan, Patrick; Colman, Jesse; Jaglom, Wendy S.; Colley, Michelle; Patel, Pralit; Eom, Jiyon; Kim, Son H.; Kyle, G. Page; Schultz, Peter; Venkatesh, Boddu; Haydel, Juanita; Mack, Charlotte; Creason, Jared

    2015-06-10

    The electric power sector both affects and is affected by climate change. Numerous studies highlight the potential of the power sector to reduce greenhouse gas emissions. Yet fewer studies have explored the physical impacts of climate change on the power sector. The present analysis examines how projected rising temperatures affect the demand for and supply of electricity. We apply a common set of temperature projections to three well-known electric sector models in the United States: the US version of the Global Change Assessment Model (GCAM-USA), the Regional Electricity Deployment System model (ReEDS), and the Integrated Planning Model (IPM®). Incorporating the effects of rising temperatures from a control scenario without emission mitigation into the models raises electricity demand by 1.6 to 6.5 % in 2050 with similar changes in emissions. The increase in system costs in the reference scenario to meet this additional demand is comparable to the change in system costs associated with decreasing power sector emissions by approximately 50 % in 2050. This result underscores the importance of adequately incorporating the effects of long-run temperature change in climate policy analysis.

  12. Impacts of Rising Air Temperatures and Emissions Mitigation on Electricity Demand and Supply in the United States. A Multi-Model Comparison

    DOE PAGESBeta

    McFarland, James; Zhou, Yuyu; Clarke, Leon; Sullivan, Patrick; Colman, Jesse; Jaglom, Wendy S.; Colley, Michelle; Patel, Pralit; Eom, Jiyon; Kim, Son H.; et al

    2015-06-10

    The electric power sector both affects and is affected by climate change. Numerous studies highlight the potential of the power sector to reduce greenhouse gas emissions. Fewer studies have explored the physical impacts of climate change on the power sector. Our present analysis examines how projected rising temperatures affect the demand for and supply of electricity. We apply a common set of temperature projections to three well-known electric sector models in the United States: the US version of the Global Change Assessment Model (GCAM-USA), the Regional Electricity Deployment System model (ReEDS), and the Integrated Planning Model (IPM®). Incorporating the effectsmore » of rising temperatures from a control scenario without emission mitigation into the models raises electricity demand by 1.6 to 6.5 % in 2050 with similar changes in emissions. Moreover, the increase in system costs in the reference scenario to meet this additional demand is comparable to the change in system costs associated with decreasing power sector emissions by approximately 50 % in 2050. This result underscores the importance of adequately incorporating the effects of long-run temperature change in climate policy analysis.« less

  13. Investigation Flow Uniformity in a Supersonic Duct with High Enthalpy Flows

    NASA Technical Reports Server (NTRS)

    Balboni, John; Atler, Doug; Gokcen, Tahir; Hartman, G. Joseph (Technical Monitor)

    1995-01-01

    Flow uniformity in a high enthalpy facility is investigated. The scramjet research facility is composed of a rectangular combustor duct connected to a 100 MW electric arc air heater. The Mach 3.3 flow is accelerated through a two-dimensional contoured nozzle. Instream measurements were made with water-cooled Pitot probes and stagnation point heat flux gages at stream enthalpy levels ranging from 4 to 7 Mj/kg. Flow surveys were made on the flow centerline and off centerline in order to measure the three dimensional uniformity of the flow in the rectangular duct. Measurements indicated that although the flow in the aspect ratio 6:1 duct was relatively uniform on the centerline, three dimensional viscous effects were apparent near the corners. Flow through the nozzle and constant area duct was modeled computationally using a two dimensional, Navier-Stokes, reacting gas code. The computations predict that the flow in the test section is in vibrational equilibrium. The computed and measured Pitot pressure and heat flux profiles are in reasonable agreement with the experimental data.

  14. Coupled parametric design of flow control and duct shape

    NASA Technical Reports Server (NTRS)

    Florea, Razvan (Inventor); Bertuccioli, Luca (Inventor)

    2009-01-01

    A method for designing gas turbine engine components using a coupled parametric analysis of part geometry and flow control is disclosed. Included are the steps of parametrically defining the geometry of the duct wall shape, parametrically defining one or more flow control actuators in the duct wall, measuring a plurality of performance parameters or metrics (e.g., flow characteristics) of the duct and comparing the results of the measurement with desired or target parameters, and selecting the optimal duct geometry and flow control for at least a portion of the duct, the selection process including evaluating the plurality of performance metrics in a pareto analysis. The use of this method in the design of inter-turbine transition ducts, serpentine ducts, inlets, diffusers, and similar components provides a design which reduces pressure losses and flow profile distortions.

  15. Curved Duct Noise Prediction Using the Fast Scattering Code

    NASA Technical Reports Server (NTRS)

    Dunn, M. H.; Tinetti, Ana F.; Farassat, F.

    2007-01-01

    Results of a study to validate the Fast Scattering Code (FSC) as a duct noise predictor, including the effects of curvature, finite impedance on the walls, and uniform background flow, are presented in this paper. Infinite duct theory was used to generate the modal content of the sound propagating within the duct. Liner effects were incorporated via a sound absorbing boundary condition on the scattering surfaces. Simulations for a rectangular duct of constant cross-sectional area have been compared to analytical solutions and experimental data. Comparisons with analytical results indicate that the code can properly calculate a given dominant mode for hardwall surfaces. Simulated acoustic behavior in the presence of lined walls (using hardwall duct modes as incident sound) is consistent with expected trends. Duct curvature was found to enhance weaker modes and reduce pressure amplitude. Agreement between simulated and experimental results for a straight duct with hard walls (no flow) was excellent.

  16. Study on numerical simulation of flowfield in afterburner for ducted rocket

    NASA Astrophysics Data System (ADS)

    Ding, Xiaoyu; Jin, Xing; Zhang, Peng

    2015-03-01

    Ducted rocket has been widely concerned on account of its high specific impulse, combustion stability and convenient maintenance which mixes the exhaust from a fuel gas generator with air from air inlet, and burns to produce thrust. It is necessary to establish two-dimensional or three-dimensional numerical models based on computational fluid dynamics to study on the flowfield in afterburner which is the key of ducted rocket because of expensive experiments, which is aimed at providing theoretical foundation for ducted rocket's development. In this paper, the gas-phase turbulent combustion process in afterburner with dual inlet three-dimensional mode was simulated numerically by solving Favre-averaged compressible turbulent N-S equations, the renormalization group (RNG) k-ɛ turbulence model was applied to simulate the turbulent flow, and Eddy-Dissipation Model (EDM) was applied to simulate gas combustion. Through simulation, situation analysis of flowfield in afterburner was done, and the influence of mixing combustion on afterburner was studied by taking air inlet angles and air-fuel ratio into account respectively. The results indicate that the distribution of temperature in afterburner is nonuniform, the backflow and axial swirl produced by gas mixing have an important influence on afterburner combustion. As air inlet angle is increased, the intensity of gas mixing is enhanced which is beneficial for afterburner combustion. That increasing air-fuel ratio is able to strength contact of oxygen with fuel gas, so that more fuel gas is consumed in the same location which is more beneficial for afterburner combustion.

  17. Hydrogen-air ignition torch

    NASA Technical Reports Server (NTRS)

    Repas, G. A.

    1986-01-01

    The design and operation of a hydrogen-air ignition torch presently being used to burn off excess hydrogen that accumulates in the scrubber exhaust ducts of two rocket engine test facilities at the NASA Lewis Research Center in Cleveland, Ohio, is described.

  18. Optimization of the mechanical performance of a two-duct semicircular duct system--part 2: excitation of endolymph movements.

    PubMed

    Muller, M; Verhagen, J H G

    2002-06-21

    The endolymph flow inside the semicircular ducts is analytically investigated by considering a system of two hydrodynamically interconnected ducts. Rotation of this system adds an amount of motion (momentum) to parts of it. This results in an endolymph flow in generally all vestibular parts. The "external impulses" are the impulses which emerge by rotation of exclusively a particular vestibular part. The real impulses can be calculated from a set of equations which contain the external impulses. Analytical expressions are derived for the initial velocities in the ducts and for the maximum endolymph displacements. These formulae contain the external impulses and the ratios of: (1) the radii of crus commune and ducts (gamma), (2) the lengths of crus commune and ducts (lambda). It was proven that an interconnected system composed of two ducts, and also a system composed of two such semicircular duct systems, behaves as a pure rotation transducer (like a single duct does), also when it is rotated excentrically. Duct systems with polygonal and circular geometries were used to evaluate whether an optimal value of lambda would exist (gamma was already considered elsewhere). Optimum values of lambda in a range of about 0.10-0.52 were found. This rather wide range of values agrees with values from measurements. Optimization of an interconnected duct system appeared to be equal to optimization of a system composed of separate ducts. PMID:12151259

  19. Contrasting the efficiency of radiation belt losses caused by ducted and non-ducted whistler mode waves from manmade transmitters

    NASA Astrophysics Data System (ADS)

    Rodger, C. J.; Carson, Bonar; Cummer, Steven A.; Gamble, R. J.; Clilverd, Mark; Sauvaud, Jean-Andre; Parrot, Michel; Green, Janet

    Electromagnetic waves in the VLF range generated at or near the Earth's surface can penetrate the ionosphere and propagate through the plasmasphere. It has long been recognized that whistler-mode waves can be trapped in localized field-aligned enhancements in plasmaspheric ionization density termed "whistler ducts", which guide the waves from one hemisphere to the other. For the non-guided cases, the whistler mode waves are said to be "nonducted". The nature of wave-particle interactions are affected by the wave being ducted or non-ducted through influence on the wave-normal angles. In the field-aligned ducted case, the dominant resonance possible is first-order cyclotron, whereas non-ducted interactions open up a much wider range of energies through equatorial and off-equatorial gyro-resonance. Thus the significance of these VLF waves as drivers of radiation belt losses is strongly influenced by whether these waves are dominantly ducted or non-ducted. At this point there is conflicting information in the literature as to whether the most significant loss processes are driven by ducted or non-ducted waves. In this study we use loss cone observations from instruments onboard the DEMETER and POES low-altitude satellites to focus on losses driven by powerful VLF communications transmitters. We wish to better characterise the losses previously reported and explained through interactions with ducted VLF transmissions. We also plan to examine losses into the atmosphere driven by non-ducted transmissions.

  20. Theoretical analysis of HVAC duct hanger systems

    NASA Technical Reports Server (NTRS)

    Miller, R. D.

    1987-01-01

    Several methods are presented which, together, may be used in the analysis of duct hanger systems over a wide range of frequencies. The finite element method (FEM) and component mode synthesis (CMS) method are used for low- to mid-frequency range computations and have been shown to yield reasonably close results. The statistical energy analysis (SEA) method yields predictions which agree with the CMS results for the 800 to 1000 Hz range provided that a sufficient number of modes participate. The CMS approach has been shown to yield valuable insight into the mid-frequency range of the analysis. It has been demonstrated that it is possible to conduct an analysis of a duct/hanger system in a cost-effective way for a wide frequency range, using several methods which overlap for several frequency bands.

  1. Porokeratotic Eccrine Ostial and Dermal Duct Nevus

    PubMed Central

    Naraghi, Mona Masoumeh; Goodarzi, Azadeh

    2013-01-01

    PEODDN is a rare benign cutaneous disorder that clinically resembles comedo nevus but favors the palms and soles, where pilosebaceous follicles are absent. Widespread involvement along Blaschko's lines can also occur. It is a disorder of keratinization involving the intraepidermal eccrine duct (acrosyringium) and is characterized by eccrine hamartoma and cornoid lamellation in pathology. The patient is a 29-year-old man with an 8-year history of pruritic skin lesions on his right lateral ankle. In the pathologic examination, multiple small epidermal invagination with overlying parakeratotic cornoid lamellation, loss of granular layer, and few dyskeratotic cells at the base of epidermal invagination are revealed. After clinic-pathologic correlation, the diagnosis of porokeratotic eccrine ostial and dermal duct nevus (PEODDN) was made. Late-onset and rare clinical presentation as pruritic lesion are the characteristic features that make this patient an extraordinary presentation of PEODDN. PMID:24307955

  2. Sea echo in tropospheric ducting environments

    NASA Astrophysics Data System (ADS)

    Pappert, R. A.; Paulus, R. A.; Tappert, F. D.

    1992-04-01

    Path loss formulas for sea surface backscatter are developed for horizontally stratified tropospheric ducting environments. First-order Bragg backscatter results coupled with ray and waveguide formalism serve as the basis for the development. Two features of composite model formalism, namely shadowing and tilting of the surface normal in the plane of incidence, are included in the development. Though developed for hh polarization, conventional composite model modifications for vertical polarization and depolarization can be incorporated into the echo models. Comparisons are made with previously generated parabolic equation results and with empirical model results generated by Engineers Refractive Effects Prediction System. These comparisons are for a frequency of 9.6 GHz for the standard atmosphere and for 14- and 28-m evaporation ducts. Results apply to wind speeds of 10, 20, 30, and 40 knots (about 5, 10, 15, and 20 m/s).

  3. Evaporation duct assessment from meteorological buoys

    NASA Astrophysics Data System (ADS)

    Hitney, Herbert V.

    2002-07-01

    The evaporation duct over the sea is usually assessed using bulk meteorological measurements. This paper investigates the utility of meteorological buoys as a source for these bulk measurements and compares evaporation duct assessments using two buoys in southern California waters separated by 128 km. A simple radio propagation experiment at 2.4 GHz between one of the buoys and the coast on an 18.2 km path is described. Observed propagation loss from this experiment is compared to modeled loss based on the meteorological measurements at each buoy. The purpose of this paper is to investigate radio propagation effects using established and accepted methods already described in the literature. Accordingly, no discussion of atmospheric surface layer meteorology affecting radio propagation is given.

  4. Low frequency sound attenuation in a flow duct using a thin slow sound material.

    PubMed

    Aurégan, Yves; Farooqui, Maaz; Groby, Jean-Philippe

    2016-05-01

    A thin subwavelength material that can be flush mounted in a duct and that gives an attenuation band at low frequencies in air flow channels is presented. To decrease the material thickness, the sound is slowed in the material using folded side branch tubes. The impedance of the material is compared to the optimal value given by the Cremer condition, which can differ greatly from the air characteristic impedance. Grazing flow on this material increases the losses at the interface between the flow and the material. PMID:27250200

  5. Ontogeny of the nasopalatine duct in primates.

    PubMed

    Shimp, Kristin L; Bhatnagar, Kunwar P; Bonar, Christopher J; Smith, Timothy D

    2003-09-01

    Ecological explanations have been put forward to account for the precocious or delayed development of patency in ducts leading to the vomeronasal organ (VNO) in certain mammals. Perinatal function may be related, in part, to the patency or fusion of the vomeronasal and nasopalatine (NPD) ducts. However, few studies have focused on NPD development in primates, which generally have a prolonged period of dependence during infancy. In this study we examined 24 prenatal primates and 13 neonatal primates, and a comparative sample of fetal mice and insectivores. In embryonic and early fetal Microcebus murinus, the NPD was completely fused, whereas in fetuses of later stages the duct was partially fused or completely patent. M. myoxinus of all stages demonstrated some degree of NPD fusion. In all other prenatal primates, the NPD was fused to some extent. Four prenatal insectivores (Tenrec ecaudatus) showed some degree of NPD fusion. In Mus musculus at 19 days gestation, the NPD was patent, although the anatomically separate VNO duct was fused. T. ecaudatus and most of the neonatal primates revealed complete NPD patency. An exception was Saguinus geoffroyi, which exhibited fusion of the NPD near the VNO opening. These observations may relate to differences in perinatal VNO function. The differences noted in our study suggest that M. murinus and M. myoxinus may differ in perinatal VNO functionality and perhaps in related behavior. Observations of neonatal primates suggest that NPD patency may be relatively common at birth and could serve other purposes in addition to being an access route for VNO stimuli. PMID:12923897

  6. Acoustic-Liner Admittance in a Duct

    NASA Technical Reports Server (NTRS)

    Watson, W. R.

    1986-01-01

    Method calculates admittance from easily obtainable values. New method for calculating acoustic-liner admittance in rectangular duct with grazing flow based on finite-element discretization of acoustic field and reposing of unknown admittance value as linear eigenvalue problem on admittance value. Problem solved by Gaussian elimination. Unlike existing methods, present method extendable to mean flows with two-dimensional boundary layers as well. In presence of shear, results of method compared well with results of Runge-Kutta integration technique.

  7. Zero leakage separable and semipermanent ducting joints

    NASA Technical Reports Server (NTRS)

    Mischel, H. T.

    1973-01-01

    A study program has been conducted to explore new methods of achieving zero leakage, separable and semipermanent, ducting joints for space flight vehicles. The study consisted of a search of literature of existing zero leakage methods, the generation of concepts of new methods of achieving the desired zero leakage criteria and the development of detailed analysis and design of a selected concept. Other techniques of leak detection were explored with a view toward improving this area.

  8. Laminar heat transfer in annular sector ducts

    SciTech Connect

    Soliman, H.M. )

    1987-02-01

    The continuing interest in compact heat exchangeers has created the need for friction factor and Nusselt number data for different passage shapes. It has long been recognized that circular tube results are generally not applicable to noncircular passages even when the hydraulic diameter is used as the characteristic dimension. Hence, design data should be generated for each passage individually, and a good source of such information is Shah and London. One duct geometry for which complete design information does not appear to be available in the open literature is that of annular sector ducts. Such configuration is encountered in multipassage internally finned tubes and many other compact het exchanger applications. The fluid flow problem for this configuration has been solved by Sparrow et al., and more recently by Niida. However, to the beest of the author's knowledge, the heat transfer results are not available yet. The purpose of this note is to summarize the analysis and results of fluid flow and heat transfer in annular sector ducts.

  9. Autoignitions and detonations in engines and ducts.

    PubMed

    Bradley, Derek

    2012-02-13

    The origins of autoignition at hot spots are analysed and the pressure pulses that arise from them are related to knock in gasoline engines and to developing detonations in ducts. In controlled autoignition engines, autoignition is benign with little knock. There are several modes of autoignition and the existence of an operational peninsula, within which detonations can develop at a hot spot, helps to explain the performance of various engines. Earlier studies by Urtiew and Oppenheim of the development of autoignitions and detonations ahead of a deflagration in ducts are interpreted further, using a simple one-dimensional theory of the generation of shock waves ahead of a turbulent flame. The theory is able to indicate entry into the domain of autoignition in an 'explosion in the explosion'. Importantly, it shows the influence of the turbulent burning velocity, and particularly its maximum attainable value, upon autoignition. This value is governed by localized flame extinctions for both turbulent and laminar flames. The theory cannot show any details of the transition to a detonation, but regimes of eventually stable or unstable detonations can be identified on the operational peninsula. Both regimes exhibit transverse waves, triple points and a cellular structure. In the case of unstable detonations, transverse waves are essential to the continuing propagation. For hazard assessment, more needs to be known about the survival, or otherwise, of detonations that emerge from a duct into the same mixture at atmospheric pressure. PMID:22213665

  10. The transient response above an evaporation duct

    NASA Astrophysics Data System (ADS)

    Abo-Seliem, Adel A. S.

    1998-11-01

    The transient electromagnetic field generated by a vertical electric dipole above an evaporation duct is investigated theoretically. The evaporation duct model used is that previously described by Kahan and Eckart. A vertical electric dipole, above the surface layer, is taken as the source of the electromagnetic field. We determine the electrical field strength exactly at some fixed point above the duct layer, having chosen a certain polarization of the primary source whose moment is allowed to vary arbitrarily with time. A series expansion with respect to the images of the primary source permits us to apply the method first reported by Cagniard and later extended by de Hoop and Frankena to the case where the source is positioned in a medium of lesser permittivity. Hence, we can give a physically intuitive description of the polarization dependence of the time history of the electrical field strength. The distinction of different cases where the distances between the receiving and transmitting ends are greater or lesser than the total reflection distance is studied. The electrical field strength is evaluated for different excitation functions at some fixed but arbitrary positions of the point of observation in the half-space.

  11. Radiative interactions in laminar duct flows

    NASA Technical Reports Server (NTRS)

    Trivedi, P. A.; Tiwari, S. N.

    1990-01-01

    Analyses and numerical procedures are presented for infrared radiative energy transfer in gases when other modes of energy transfer occur simultaneously. Two types of geometries are considered, a parallel plate duct and a circular duct. Fully developed laminar incompressible flows of absorbing-emitting species in black surfaced ducts are considered under the conditions of uniform wall heat flux. The participating species considered are OH, CO, CO2, and H2O. Nongray as well as gray formulations are developed for both geometries. Appropriate limiting solutions of the governing equations are obtained and conduction-radiation interaction parameters are evaluated. Tien and Lowder's wide band model correlation was used in nongray formulation. Numerical procedures are presented to solve the integro-differential equations for both geometries. The range of physical variables considered are 300 to 2000 K for temperature, 0.1 to 100.0 atm for pressure, and 0.1 to 100 cm spacings between plates/radius of the tube. An extensive parametric study based on nongray formulation is presented. Results obtained for different flow conditions indicate that the radiative interactions can be quite significant in fully developed incompressible flows.

  12. Pronephric duct extension in amphibian embryos: migration and other mechanisms.

    PubMed

    Drawbridge, Julie; Meighan, Christopher M; Lumpkins, Rebecca; Kite, Mary E

    2003-01-01

    Initiation of excretory system development in all vertebrates requires (1) delamination of the pronephric and pronephric duct rudiments from intermediate mesoderm at the ventral border of anterior somites, and (2) extension of the pronephric duct to the cloaca. Pronephric duct extension is the central event in nephric system development; the pronephric duct differentiates into the tubule that carries nephric filtrate out of the body and induces terminal differentiation of adult kidneys. Early studies concluded that pronephric ducts formed by means of in situ segregation of pronephric duct tissue from lateral mesoderm ventral to the forming somites; more recent studies highlight caudal migration of the pronephric duct as the major morphogenetic mechanism. The purpose of this review is to provide the historical background on studies of the mechanisms of amphibian pronephric duct extension, to review evidence showing that different amphibians perform pronephric duct morphogenesis in different ways, and to suggest future studies that may help illuminate the molecular basis of the mechanisms that have evolved in amphibians to extend the pronephric duct to the cloaca. PMID:12508219

  13. Accessory Pancreatic Duct Patterns and Their Clinical Implications

    PubMed Central

    Prasanna, Lokadolalu Chandracharya; Rajagopal, KV; Thomas, Huban R

    2015-01-01

    Context and Objective: Accessory pancreatic duct (APD) designed to reduce the pressure of major pancreatic duct by forming a secondary drainage channel. Few studies have mentioned the variant types of accessory ducts and their mode of formation, some of these have a clear clinical significance. Present study is aimed to evaluate the possible variations in the APD and its terminations. Materials and Methods: Forty formalin fixed adult human pancreas with duodenum in situ specimens were studied by injecting 1% aqueous eosin, followed by piece meal dissection of the head of the pancreas from posterior surface. Formation, tributaries, relations, and the termination of the accessory pancreatic duct were noted and photographed. Results: Accessory ducts revealed 50% belonged to long type, 22.5% were of short and ansa pancreatica type each, and embryonic type of duct pattern was seen in 5% specimens. 75% of long type ducts showed positive patency with eosin dye, followed by ansa type (44.4%), and least patency was found in short type (22.2%). With regard to the patency of the accessory pancreatic ducts towards their termination, we found 52.5% of the accessory ducts and 5% of the embryonic type pancreatic ducts were patent and in 42.5% of the specimen the ducts were obliterated. In 85% of specimens the minor duodenal papillae was anterosuperior to the major papilla and superior to the major papillae in 10% of the cases, and in 5% minor papillae was absent. The average distance between the two papillae was 2.35 cm. Conclusion: The knowledge of the complex anatomical relations of the gland with its duct, duodenum and bile ducts are essential for the surgeons and sinologists to plan and perform both the diagnostic as well as therapeutic procedures effectively. PMID:25954609

  14. 32 CFR 855.19 - Supply and service charges.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....19 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE AIRCRAFT CIVIL AIRCRAFT USE OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.19 Supply and..., volume 1, part one, chapter 10, section N, Basic Air Force Supply Procedures, and AFR 177-102,...

  15. 32 CFR 855.19 - Supply and service charges.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....19 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE AIRCRAFT CIVIL AIRCRAFT USE OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.19 Supply and..., volume 1, part one, chapter 10, section N, Basic Air Force Supply Procedures, and AFR 177-102,...

  16. 32 CFR 855.19 - Supply and service charges.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....19 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE AIRCRAFT CIVIL AIRCRAFT USE OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.19 Supply and..., volume 1, part one, chapter 10, section N, Basic Air Force Supply Procedures, and AFR 177-102,...

  17. 32 CFR 855.19 - Supply and service charges.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....19 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE AIRCRAFT CIVIL AIRCRAFT USE OF UNITED STATES AIR FORCE AIRFIELDS Civil Aircraft Landing Permits § 855.19 Supply and..., volume 1, part one, chapter 10, section N, Basic Air Force Supply Procedures, and AFR 177-102,...

  18. Into Thin Air.

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2001-01-01

    Shows how schools are working to avoid the types of equipment, supplies, and maintenance practices that harm indoor air quality. Simple steps to maintaining a cleaner indoor air environment are highlighted as are steps to reducing the problem air quality and the occurrence of asthma. (GR)

  19. Measuring Outdoor Air Intake Rates into Existing Building

    SciTech Connect

    Fisk, William; Sullivan, Douglas; Cohen, Sebastian; Han, Hwataik

    2009-04-16

    Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

  20. Duct wall impedance control as an advanced concept for acoustic suppression enhancement. [engine noise reduction

    NASA Technical Reports Server (NTRS)

    Dean, P. D.

    1978-01-01

    A systems concept procedure is described for the optimization of acoustic duct liner design for both uniform and multisegment types. The concept was implemented by the use of a double reverberant chamber flow duct facility coupled with sophisticated computer control and acoustic analysis systems. The optimization procedure for liner insertion loss was based on the concept of variable liner impedance produced by bias air flow through a multilayer, resonant cavity liner. A multiple microphone technique for in situ wall impedance measurements was used and successfully adapted to produce automated measurements for all liner configurations tested. The complete validation of the systems concept was prevented by the inability to optimize the insertion loss using bias flow induced wall impedance changes. This inability appeared to be a direct function of the presence of a higher order energy carrying modes which were not influenced significantly by the wall impedance changes.

  1. Effect of flow on the acoustic performance of extended reaction lined ducts

    NASA Technical Reports Server (NTRS)

    Hersh, A. S.; Walker, B.

    1983-01-01

    A model is developed for the effects of uniform and boundary-layer mean flow on the attenuation and propagation of harmonically excited sound waves in an extended reaction lined cylindrical duct. A duct geometry consisting of an annular outer region of bulk material surrounding an inner cylinder of air is utilized. A numerical solution is obtained for the coupled wave equations governing the motion of the sound in both the inner and annular regions. It is found that the numerically predicted attenuation and propagations constants are in excellent agreement with measured values using Kevlar as the liner material for plane-wave mode (O,O) excitation over a wide range of mean flows and sound frequency. The boundary-layer effects are determined to be unimportant, at least for plane-wave sound. In addition, numerical studies indicate small differences between the use of either the radial velocity or the radial displacement boundary conditions.

  2. Peripheral temperature variation in the wall of a noncircular duct - An experimental investigation

    NASA Astrophysics Data System (ADS)

    Barrow, H.; Hassan, A. K. A.; Avgerinos, C.

    1984-07-01

    This paper is concerned with the peripheral variation of the temperature in the wall of a straight noncircular duct, with special reference to the prediction of the temperature in the cladding of the fuel rods of a pressurized water reactor, in the event of a loss of coolant. A simple model of the conjugate heat transfers in the wall and the fluid is used to predict the temperature variation around the wall. To test the theory, experiments have been made to determine wall temperatures in a cusped duct using air as the working fluid for a range of fluid flow rates. Overall pressure drop and heat transfer measurements for friction factor and average heat transfer coefficient indicate the inadequacy of the hydraulic radius concept in the case of the very noncircular geometry used in the experiments, and the effect of asymmetry in heat transfer. It is thought that these heat transfer experiments are the first for this particular geometry.

  3. Method and apparatus for duct sealing using a clog-resistant insertable injector

    DOEpatents

    Wang, Duo; Modera, Mark P.

    2007-01-02

    A clog-resistant injector spray nozzle allows relatively unobtrusive insertion through a small access aperture into existing ductwork in occupied buildings for atomized particulate sealing of a ductwork. The spray nozzle comprises an easily cleaned and easily replaced straight liquid tube whose liquid contents are principally propelled by a heated propellant gas, such as heated air. Heat transfer is minimized from the heated propellant gas to the liquid tube until they both exit the injector, thereby greatly reducing the likelihood of nozzle clogging. A method of duct sealing using particles driven by heated propellant gas is described, whereby duct-sealing operations become both faster, and commercially practicable in inhabited commercial and residential buildings.

  4. Experimental validation of a ducted propeller analysis method

    NASA Astrophysics Data System (ADS)

    Hughes, M. J.; Kinnas, S. A.; Kerwin, J. E.

    1992-06-01

    A ducted propeller model was tested in the MIT water tunnel. A hub apparatus was designed which allowed for the duct and propeller forces to be measured separately. The forces on the duct and propeller were measured over a range of advance coefficients. Velocities were measured upstream and downstream from the duct using a Laser Doppler Velocimetry system. Using these velocities the exprimental values for the spanwise distribution of circulation on the propeller blades were then calculated. The experimental results were compared to the results from a propeller lifting surface/duct and hub surface panel analysis code over the same range of advance coefficients showing very good agreement for the duct and propeller forces and the circulation in the region of attached flow.

  5. Optimization of the mechanical performance of a two-duct semicircular duct system--part 3: the positioning of the ducts in the head.

    PubMed

    Muller, M; Verhagen, J H G

    2002-06-21

    In the majority of vertebrates, the horizontal duct of the vestibular system lies approximately in the yawing plane of the head. The positioning of the vertical ducts, however, is not in the pitch- and roll planes but the vertical ducts generally lie under an angle of about 30-45 degrees relative to the medial plane. Using the equations for a hydrodynamically interconnected two-duct system, optimal positions of the vertical and horizontal ducts in different vertebrate groups can be derived. It was stated that the mean response of the vertical ducts should be optimized. This leads to a symmetrical positioning of the vertical ducts with respect to the medial plane. In all observed vertebrate groups, a solution of mu =(pi-alpha)/2 is found (mu is the angle of the vertical ducts relative to the medial plane, alpha is the angle between the vertical duct planes). For alpha=90 degrees, this provides an equal sensitivity for pitch- and roll- movements. For alpha>90 degrees, a larger sensitivity for pitch movements is obtained, at the expense of a lower sensitivity for roll movements. It is argued that the angle alpha between the vertical ducts may vary from 90 to 120 degrees. In most vertebrates, the centre of mass is stabilized by e.g. fins, tri- or quadrupedal stability, a crawling body or upside-down resting positions (e.g. bats). Birds are generally biped, so in walking they are also rather sensitive to roll. These features are related to labyrinth positioning in the head. PMID:12151260

  6. Design and evaluation of a low nitrogen oxides natural gas-fired conical wire-mesh duct burner for a micro-cogeneration unit

    NASA Astrophysics Data System (ADS)

    Ramadan, Omar Barka Ab

    A novel low NOx conical wire-mesh duct burner was designed, built and tested in the present research. This thesis documents the design process and the in-depth evaluation of this novel duct burner for the development of a more efficient micro-cogeneration unit. This duct burner provides the thermal energy necessary to raise the microturbine exhaust gases temperature to increase the heat recovery capability. The duct burner implements both lean-premixed and surface combustion techniques to achieve low NOx and CO emissions. The design of the duct burner was supported by a qualitative flow visualization study for the duct burner premixer to provide insight into the premixer flow field (mixing process). Different premixer geometries were used to control the homogeneity of the fuel-oxidant mixture at the exit of the duct burner premixer. Laser sheet illumination (LSI) technique was used to capture images of the mixing process, for each configuration studied. A quasi-quantitative analysis technique was developed to rank the different premixer geometries in terms of mixing effectiveness. The premixer geometries that provided better mixing were selected and used for the combustion tests. The full-scale gas-fired duct burner was installed in the exhaust duct of a micro-cogeneration unit for the evaluation. Three wire-mesh burners with different pressure drops were used. Each burner has a conical shape made from FeCrAL alloy mat and was designed based on a heat release per unit area of 2500 kW/m2 and a total heat release of 240kW at 100 percent excess air. The local momentum of the gaseous mixture introduced through the wire-mesh was adjusted so that the flame stabilized outside the burner mesh (surface combustion). Cold flow tests (i.e., the duct burner was off, but the microturbine was running) were conducted to measure the effect of different duct burner geometrical parameters on flow split between the combustion zone and the bypass channel, and on pressure drop across

  7. Patent vitellointestinal duct as paraumblical abcess: A rare presentation

    PubMed Central

    Rekhi, Harnam Singh; Mittal, Sushil; Singh, Gurtej; Rekhi, Balwinder Kaur; Dugg, Pankaj

    2015-01-01

    Introduction Umbilical and paraumblical abscess can occur in children with presenting complaint of discharge from umbilical region. However, patent vitello intestinal duct presenting as paraumblical abscess is rare phenomenon. Presentation of case One year old male child presented with complain of discharge from umbilical region since birth. Incision & drainage done twice thinking it to be paraumblical abscess. Discussion Vitellointestinal duct as abscess is rare presentation but it should be considered as a differential diagnosis of discharging umbilicus as management of abscess and patent duct are different. Conclusion Patent vitellointestinal duct can present as paraumbilical abscess, and it should be kept in differential diagnosis specifically in children. PMID:26301682

  8. Duct injection technology prototype development: Evaluation of engineering data

    SciTech Connect

    Not Available

    1990-07-01

    The objective of the Duct Injection Technology Prototype Development Project is to develop a sound design basis for applying duct injection technology as a post-combustion SO{sub 2}emissions control method to existing coal-fired power plants. The necessary engineering design and scale-up criteria will be developed for the commercialization of duct injection technology for the control of SO{sub 2} emissions from coal-fired boilers in the utility industry. The primary focus of the analyses summarized in this Topical Report is the review of the known technical and economic information associated with duct injection technology. (VC)

  9. Duct Remediation Program: Engineered access research and construction

    SciTech Connect

    Beckman, T.D.; Davis, M.M.; Karas, T.M.

    1992-11-01

    The Rocky Flats Plant, Duct Remediation mission concentrated on removing Plutonium Oxide from the process ductwork in the primary Plutonium processing facility. When possible, remediation took place from existing process gloveboxes. Fifteen locations were identified, however, that required accessing duct runs where no process gloveboxes existed. The building`s second floor utility areas had many locations where long, inaccessible duct runs were prevalent. Consequently, an extensive program for design, procurement and construction was initiated to contain and isolate ducts for penetration when existing glovebox sites were not present.

  10. Leaf seal for transition duct in turbine system

    SciTech Connect

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2013-06-11

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a leaf seal contacting the interface member to provide a seal between the interface member and the turbine section.

  11. Convolution seal for transition duct in turbine system

    SciTech Connect

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2015-03-10

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a convolution seal contacting the interface member to provide a seal between the interface member and the turbine section.

  12. Flexible metallic seal for transition duct in turbine system

    SciTech Connect

    Flanagan, James Scott; LeBegue, Jeffrey Scott; McMahan, Kevin Weston; Dillard, Daniel Jackson; Pentecost, Ronnie Ray

    2014-04-22

    A turbine system is disclosed. In one embodiment, the turbine system includes a transition duct. The transition duct includes an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The transition duct further includes an interface member for interfacing with a turbine section. The turbine system further includes a flexible metallic seal contacting the interface member to provide a seal between the interface member and the turbine section.

  13. Buried and Encapsulated Ducts, Jacksonville, Florida (Fact Sheet)

    SciTech Connect

    Not Available

    2013-11-01

    Ductwork installed in unconditioned attics can significantly increase the overall heating and cooling costs of residential buildings. In fact, estimated duct thermal losses for single-family residential buildings with ductwork installed in unconditioned attics range from 10% to 45%. In a study of three single-story houses in Florida, the Building America research team Consortium for Advanced Residential Buildings (CARB) investigated the strategy of using buried and/or encapsulated ducts (BED) to reduce duct thermal losses in existing homes. The BED strategy consists of burying ducts in loose-fill insulation and/or encapsulating them in closed cell polyurethane spray foam (ccSPF) insulation. There are three possible combinations of BED strategies: (1) buried ducts; (2) encapsulated ducts (with ccSPF); and (3) buried and encapsulated ducts. The best solution for each situation depends on the climate, age of the house, and the configuration of the HVAC system and attic. For new construction projects, the team recommends that ducts be both encapsulated and buried as the minimal planning and costs required for this will yield optimal energy savings. The encapsulated/buried duct strategy, which utilizes ccSPF to address condensation concerns, is an approach that was developed specifically for humid climates.

  14. Analysis of nephric duct specification in the avian embryo

    PubMed Central

    Attia, Lital; Yelin, Ronit; Schultheiss, Thomas M.

    2012-01-01

    Vertebrate kidney tissue exhibits variable morphology that in general increases in complexity when moving from anterior to posterior along the body axis. The nephric duct, a simple unbranched epithelial tube, is derived in the avian embryo from a rudiment located in the anterior intermediate mesoderm (IM) adjacent to somites 8 to 10. Using quail-chick chimeric embryos, the current study finds that competence to form nephric duct is fixed when IM precursor cells are still located in the primitive streak, significantly before the onset of duct differentiation. In the primitive streak, expression of the gene HoxB4 is associated with prospective duct IM, whereas expression of the more posterior Hox gene HoxA6 is associated with more posterior, non-duct-forming IM. Misexpression of HoxA6, but not of HoxB4, in prospective duct-forming regions of the IM resulted in repression of duct formation, suggesting a mechanism for the restriction of duct formation to the anterior-most IM. The results are discussed with respect to their implications for anterior-posterior patterning of kidney tissue and of mesoderm in general, and for the loss of duct-forming ability in more posterior regions of the IM that has occurred during vertebrate evolution. PMID:23034630

  15. 24 CFR 3280.715 - Circulating air systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Circulating air systems. 3280.715... Systems § 3280.715 Circulating air systems. Link to an amendment published at 78 FR 73989, Dec. 9, 2013... steel, tin-plated steel, or aluminum, or shall be listed Class 0, Class 1, or Class 2 air ducts. Class...

  16. Postoperative Chemoradiotherapy for Extrahepatic Bile Duct Cancer

    SciTech Connect

    Park, Jin-hong; Choi, Eun Kyung; Ahn, Seung Do; Lee, Sang-wook; Song, Si Yeol; Yoon, Sang Min; Kim, Young Seok; Lee, Yu Sun; Lee, Sung-Gyu; Hwang, Shin; Lee, Young-Joo; Park, Kwang-Min; Kim, Tae Won; Chang, Heung Moon; Lee, Jae-Lyun; Kim, Jong Hoon

    2011-03-01

    Purpose: To evaluate the effect of postoperative concurrent chemoradiotherapy using three-dimensional conformal radiotherapy and to identify the prognostic factors that influence survival in patients with extrahepatic bile duct cancer. Methods and Materials: We retrospectively analyzed the data from 101 patients with extrahepatic bile duct cancer who had undergone postoperative concurrent chemoradiotherapy using three-dimensional conformal radiotherapy. Of the 101 patients, 52 (51%) had undergone complete resection (R0 resection) and 49 (49%) had microscopic or macroscopic residual tumors (R1 or R2 resection). The median radiation dose was 50 Gy. Also, 85 patients (84%) underwent concurrent chemotherapy with 5-fluorouracil. Results: The median follow-up period was 47 months for the surviving patients. The 5-year overall survival rate was 34% for all patients. A comparison between patients with R0 and R1 resection indicated no significant difference in the 5-year overall survival (44% vs. 33%, p = .2779), progression-free survival (35% vs. 22%, p = .3107), or locoregional progression-free survival (75% vs. 63%, p = .2784) rates. An analysis of the first failure site in the 89 patients with R0 or R1 resection indicated isolated locoregional recurrence in 7 patients. Elevated postoperative carbohydrate antigen 19-9 level was an independent prognostic factor for overall survival (p = .001) and progression-free survival (p = .033). A total of 3 patients developed Grade 3 or greater late toxicity. Conclusion: Adjuvant concurrent chemoradiotherapy using three-dimensional conformal radiotherapy appears to improve locoregional control and survival in extrahepatic bile duct cancer patients with R1 resection. The postoperative carbohydrate antigen 19-9 level might be a useful prognostic marker to select patients for more intensified adjuvant therapy.

  17. Radiation of sound from unflanged cylindrical ducts

    NASA Technical Reports Server (NTRS)

    Hartharan, S. L.; Bayliss, A.

    1983-01-01

    Calculations of sound radiated from unflanged cylindrical ducts are presented. The numerical simulation models the problem of an aero-engine inlet. The time dependent linearized Euler equations are solved from a state of rest until a harmonic solution is attained. A fourth order accurate finite difference scheme is used and solutions are obtained from a fully vectorized Cyber-203 computer program. Cases of both plane waves and spin modes are treated. Spin modes model the sound generated by a turbofan engine. Boundary conditions for both plane waves and spin modes are treated. Solutions obtained are compared with experiments conducted at NASA Langley Research Center.

  18. Levitated Duct Fan (LDF) Aircraft Auxiliary Generator

    NASA Technical Reports Server (NTRS)

    Eichenberg, Dennis J.; Emerson, Dawn C.; Gallo, Christopher A.; Thompson, William K.

    2011-01-01

    This generator concept includes a novel stator and rotor architecture made from composite material with blades attached to the outer rotating shell of a ducted fan drum rotor, a non-contact support system between the stator and rotor using magnetic fields to provide levitation, and an integrated electromagnetic generation system. The magnetic suspension between the rotor and the stator suspends and supports the rotor within the stator housing using permanent magnets attached to the outer circumference of the drum rotor and passive levitation coils in the stator shell. The magnets are arranged in a Halbach array configuration.

  19. Anatomy of the nipple and breast ducts.

    PubMed

    Zucca-Matthes, Gustavo; Urban, Cícero; Vallejo, André

    2016-02-01

    Over time, variations of mastectomy came up and started allowing the oncological safety and the possibility of an immediate breast reconstruction. Nipple sparing mastectomy (NSM) procedures have strongly increased in frequency and have become one of the best alternatives to treat breast cancer, also improving overall aesthetic outcomes and the achievement of contralateral breast symmetry. The nipple areola-complex (NAC) must be considered the identity of the breast concerning self-esteem of patients. This paper will remind the main anatomical topics around the nipple and breast ducts. PMID:26855906

  20. [Carcinoma of the extrahepatic bile ducts].

    PubMed

    Cappelletti, F; Marzano, P F; Giacinti, I; Di Bello, M G; Maturo, A; Di Matteo, F M; Micacchi, M; Zaccagnino, P; Morucci, R; Petrassi, P; Ascenzi, P; Di Curzio, B

    1996-01-01

    In the last 5 years 25 patients (11 men, 14 women) with carcinoma of the extrahepatic biliary duct were studied. The most frequent localization of the carcinoma was the hepatic hilum. D.C.P. according to Whipple was possible only in one patient, while in 20 patients a palliative approach with external and internal biliary derivations was the choice. In the remaining 4 patients an explorative laparotomy with biopsy was performed. It is concluded that palliative resection allows for a better quality of life. PMID:9162182