Sample records for air terminal devices

  1. A Transportable VLF/LF Repeater Terminal - A Design Study,

    DTIC Science & Technology

    1986-07-01

    Corporation and marketed commercially as the ROLM 1602B, is expected to be used on the Airborne Command Post (ABNCP) fleet for MMPM processing. The basic...A suitable keyboard/printer for this application is a solid state teletype, the AN/ UGC -120. This device can also function as an AFSATCOM terminal...and as the VLF output device in the event of CPU failure. The AN/ UGC -120 is an Air Force inventory item. 20 INTERSITE COW4UNICATIONS SUBSYSTEM A single

  2. Multi-terminal remote monitoring and warning system using Micro Air Vehicle for dangerous environment

    NASA Astrophysics Data System (ADS)

    Yu, Yanan; Wang, Xiaoxun; He, Chengcheng; Lai, Chenlong; Liu, Yuanchao

    2015-11-01

    For overcoming the problems such as remote operation and dangerous tasks, multi-terminal remote monitoring and warning system based on STC89C52 Micro Control Unit and wireless communication technique was proposed. The system with MCU as its core adopted multiple sets of sensor device to monitor environment parameters of different locations, such as temperature, humidity, smoke other harmful gas concentration. Data information collected was transmitted remotely by wireless transceiver module, and then multi-channel data parameter was processed and displayed through serial communication protocol between the module and PC. The results of system could be checked in the form of web pages within a local network which plays a wireless monitoring and warning role. In a remote operation, four-rotor micro air vehicle which fixed airborne data acquisition device was utilized as a middleware between collecting terminal and PC to increase monitoring scope. Whole test system has characteristics of simple construction, convenience, real time ability and high reliability, which could meet the requirements of actual use.

  3. MAGTF (Marine Air Ground Task Force) Data Transfer Alternatives (1986-1996).

    DTIC Science & Technology

    1986-04-01

    Devices currently on the market offer circuit conditioning and access control as well as the required dial-up connectivity. A program to provide dial... UGC -74A(V)3 Communication Terminal (Teletype Writer (TTY) CV-3591 Advanced Narrowband Digital Voice Terminal (ANDVT) AN/TGC-46 TTY Central (part of AN...interface directly with both AN/ UGC -74 TTY and ADPE-FMF/EUC equipment over serial circuits. 5.5.2.2 Switching Equipment. Switching equipments perform the

  4. Development and evaluation of a Kalman-filter algorithm for terminal area navigation using sensors of moderate accuracy

    NASA Technical Reports Server (NTRS)

    Kanning, G.; Cicolani, L. S.; Schmidt, S. F.

    1983-01-01

    Translational state estimation in terminal area operations, using a set of commonly available position, air data, and acceleration sensors, is described. Kalman filtering is applied to obtain maximum estimation accuracy from the sensors but feasibility in real-time computations requires a variety of approximations and devices aimed at minimizing the required computation time with only negligible loss of accuracy. Accuracy behavior throughout the terminal area, its relation to sensor accuracy, its effect on trajectory tracking errors and control activity in an automatic flight control system, and its adequacy in terms of existing criteria for various terminal area operations are examined. The principal investigative tool is a simulation of the system.

  5. CAD/CAM-designed 3D-printed electroanalytical cell for the evaluation of nanostructured gas-diffusion electrodes

    NASA Astrophysics Data System (ADS)

    Chervin, Christopher N.; Parker, Joseph F.; Nelson, Eric S.; Rolison, Debra R.; Long, Jeffrey W.

    2016-04-01

    The ability to effectively screen and validate gas-diffusion electrodes is critical to the development of next-generation metal-air batteries and regenerative fuel cells. The limiting electrode in a classic two-terminal device such as a battery or fuel cell is difficult to discern without an internal reference electrode, but the flooded electrolyte characteristic of three-electrode electroanalytical cells negates the prime function of an air electrode—a void volume freely accessible to gases. The nanostructured catalysts that drive the energy-conversion reactions (e.g., oxygen reduction and evolution in the air electrode of metal-air batteries) are best evaluated in the electrode structure as-used in the practical device. We have designed, 3D-printed, and characterized an air-breathing, thermodynamically referenced electroanalytical cell that allows us to mimic the Janus arrangement of the gas-diffusion electrode in a metal-air cell: one face freely exposed to gases, the other wetted by electrolyte.

  6. CAD/CAM-designed 3D-printed electroanalytical cell for the evaluation of nanostructured gas-diffusion electrodes.

    PubMed

    Chervin, Christopher N; Parker, Joseph F; Nelson, Eric S; Rolison, Debra R; Long, Jeffrey W

    2016-04-29

    The ability to effectively screen and validate gas-diffusion electrodes is critical to the development of next-generation metal-air batteries and regenerative fuel cells. The limiting electrode in a classic two-terminal device such as a battery or fuel cell is difficult to discern without an internal reference electrode, but the flooded electrolyte characteristic of three-electrode electroanalytical cells negates the prime function of an air electrode-a void volume freely accessible to gases. The nanostructured catalysts that drive the energy-conversion reactions (e.g., oxygen reduction and evolution in the air electrode of metal-air batteries) are best evaluated in the electrode structure as-used in the practical device. We have designed, 3D-printed, and characterized an air-breathing, thermodynamically referenced electroanalytical cell that allows us to mimic the Janus arrangement of the gas-diffusion electrode in a metal-air cell: one face freely exposed to gases, the other wetted by electrolyte.

  7. Command, Control, Communications, Computers and Intelligence Electronic Warfare (C4IEW) Project Book, Fiscal Year 1994. (Non-FOUO Version)

    DTIC Science & Technology

    1994-04-01

    TSW-7A, AIR TRAFFIC CONTROL CENTRAL (ATCC) 32- 8 AN/TTC-41(V), CENTRAL OFFICE, TELEPHONE, AUTOMATIC 32- 9 MISSILE COUNTERMEASURE DEVICE (MCD) .- 0 MK...a Handheld Terminal Unit (HTU), Portable Computer Unit (PCU), Transportable Computer Unit (TCU), and compatible NOI peripheral devices . All but the...CLASSIFICATION: ASARC-III, Jun 80, Standard. I I I AN/TIC-39 IS A MOBILE , AUTOMATIC , MODULAR ELECTRONIC CIRCUIT SWITCH UNDER PROCESSOR CONTROL WITH INTEGRAL

  8. MMIC Phased Array Demonstrations with ACTS

    NASA Technical Reports Server (NTRS)

    Raquet, Charles A. (Compiler); Martzaklis, Konstantinos (Compiler); Zakrajsek, Robert J. (Compiler); Andro, Monty (Compiler); Turtle, John P.

    1996-01-01

    Over a one year period from May 1994 to May 1995, a number of demonstrations were conducted by the NASA Lewis Research Center (LeRC) in which voice, data, and/or video links were established via NASA's advanced communications technology satellite (ACTS) between the ACTS link evaluation terminal (LET) in Cleveland, OH, and aeronautical and mobile or fixed Earth terminals having monolithic microwave integrated circuit (MMIC) phased array antenna systems. This paper describes four of these. In one, a duplex voice link between an aeronautical terminal on the LeRC Learjet and the ACTS was achieved. Two others demonstrated duplex voice (and in one case video as well) links between the ACTS and an Army vehicle. The fourth demonstrated a high data rate downlink from ACTS to a fixed terminal. Array antenna systems used in these demonstrations were developed by LeRC and featured LeRC and Air Force experimental arrays using gallium arsenide MMIC devices at each radiating element for electronic beam steering and distributed power amplification. The single 30 GHz transmit array was developed by NASA/LeRC and Texas Instruments. The three 20 GHz receive arrays were developed in a cooperative effort with the Air Force Rome Laboratory, taking advantage of existing Air Force array development contracts with Boeing and Lockheed Martin. The paper describes the four proof-of-concept arrays and the array control system. The system configured for each of the demonstrations is described, and results are discussed.

  9. 78 FR 17890 - Energy Efficiency Program for Commercial and Industrial Equipment: Public Meeting and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-25

    ... Document for Packaged Terminal Air Conditioners and Packaged Terminal Heat Pumps AGENCY: Office of Energy... must identify the framework document for packaged terminal air conditioners and packaged terminal heat... packaged terminal air conditioners and packaged terminal heat pumps. 78 FR 12252. The document provided for...

  10. 47 CFR 15.115 - TV interface devices, including cable system terminal devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... output terminal(s) of the device terminated by a resistance equal to the rated output impedance. The... ohms) matching the rated output impedance of the TV interface device, shall not exceed the following... during maximum amplitude peaks across a resistance (R in ohms) matching the rated output impedance of the...

  11. 47 CFR 15.115 - TV interface devices, including cable system terminal devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... output terminal(s) of the device terminated by a resistance equal to the rated output impedance. The... ohms) matching the rated output impedance of the TV interface device, shall not exceed the following... during maximum amplitude peaks across a resistance (R in ohms) matching the rated output impedance of the...

  12. Automated Air Information Production System - Phase II.

    DTIC Science & Technology

    1980-10-01

    Alphanumeric CRT terminals, 2 Gandalf Data Inc. Model LDS 250/3 56 Kbps synchronous short haul modems , 2 General Data Comm Industries TDM-1205 time...supplied encrypt/decrypt devices which would interface to the communications multiplexers supplied by Synectics. Synectics also supplied short haul modems ...During the development effort and throughput of the T&E period the high speed ( 56K bps) link would intermittently go out of synchronization. The problem

  13. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of small, large, and very large...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., packaged terminal air conditioners, and packaged terminal heat pumps. 431.96 Section 431.96 Energy... EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the... heating equipment, packaged terminal air conditioners, and packaged terminal heat pumps. (a) Scope. This...

  14. 10 CFR 431.96 - Uniform test method for the measurement of energy efficiency of small, large, and very large...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., packaged terminal air conditioners, and packaged terminal heat pumps. 431.96 Section 431.96 Energy... EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the... heating equipment, packaged terminal air conditioners, and packaged terminal heat pumps. (a) Scope. This...

  15. Graded junction termination extensions for electronic devices

    NASA Technical Reports Server (NTRS)

    Merrett, J. Neil (Inventor); Isaacs-Smith, Tamara (Inventor); Sheridan, David C. (Inventor); Williams, John R. (Inventor)

    2006-01-01

    A graded junction termination extension in a silicon carbide (SiC) semiconductor device and method of its fabrication using ion implementation techniques is provided for high power devices. The properties of silicon carbide (SiC) make this wide band gap semiconductor a promising material for high power devices. This potential is demonstrated in various devices such as p-n diodes, Schottky diodes, bipolar junction transistors, thyristors, etc. These devices require adequate and affordable termination techniques to reduce leakage current and increase breakdown voltage in order to maximize power handling capabilities. The graded junction termination extension disclosed is effective, self-aligned, and simplifies the implementation process.

  16. Graded junction termination extensions for electronic devices

    NASA Technical Reports Server (NTRS)

    Merrett, J. Neil (Inventor); Isaacs-Smith, Tamara (Inventor); Sheridan, David C. (Inventor); Williams, John R. (Inventor)

    2007-01-01

    A graded junction termination extension in a silicon carbide (SiC) semiconductor device and method of its fabrication using ion implementation techniques is provided for high power devices. The properties of silicon carbide (SiC) make this wide band gap semiconductor a promising material for high power devices. This potential is demonstrated in various devices such as p-n diodes, Schottky diodes, bipolar junction transistors, thyristors, etc. These devices require adequate and affordable termination techniques to reduce leakage current and increase breakdown voltage in order to maximize power handling capabilities. The graded junction termination extension disclosed is effective, self-aligned, and simplifies the implementation process.

  17. GaInP2/GaAs tandem cells for space applications

    NASA Technical Reports Server (NTRS)

    Olson, J. M.; Kurtz, S. R.; Kibbler, A. E.; Bertness, K. A.; Friedman, D. J.

    1991-01-01

    The monolithic, tunnel-junction-interconnected tandem combination of a GaInP2 top cell and a GaAs bottom cell has achieved a one-sun, AM1.5 efficiency of 27.3 percent. With proper design of the top cell, air mass zero (AM0) efficiencies greater than 25 percent are possible. A description and the advantages of this device for space applications are presented and discussed. The advantages include high-voltage, low-current, two-terminal operation for simple panel fabrication, and high conversion efficiency with low-temperature coefficient. Also, because the active regions of the device are Al-free, the growth of high efficiency devices is not affected by trace levels of O2 or H2O in the MOCVD growth system.

  18. 42 CFR 136a.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pregnancies. 136a.55 Section 136a.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... and devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices... termination of an ectopic pregnancy. ...

  19. 42 CFR 136a.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... pregnancies. 136a.55 Section 136a.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... and devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices... termination of an ectopic pregnancy. ...

  20. 42 CFR 136a.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... pregnancies. 136a.55 Section 136a.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... and devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices... termination of an ectopic pregnancy. ...

  1. 42 CFR 136a.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... pregnancies. 136a.55 Section 136a.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... and devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices... termination of an ectopic pregnancy. ...

  2. 42 CFR 136a.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... pregnancies. 136a.55 Section 136a.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... and devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices... termination of an ectopic pregnancy. ...

  3. Pseudo-Hall Effect in Graphite on Paper Based Four Terminal Devices for Stress Sensing Applications

    NASA Astrophysics Data System (ADS)

    Qamar, Afzaal; Sarwar, Tuba; Dinh, Toan; Foisal, A. R. M.; Phan, Hoang-Phuong; Viet Dao, Dzung

    2017-04-01

    A cost effective and easy to fabricate stress sensor based on pseudo-Hall effect in Graphite on Paper (GOP) has been presented in this article. The four terminal devices were developed by pencil drawing with hand on to the paper substrate. The stress was applied to the paper containing four terminal devices with the input current applied at two terminals and the offset voltage observed at other two terminals called pseudo-Hall effect. The GOP stress sensor showed significant response to the applied stress which was smooth and linear. These results showed that the pseudo-Hall effect in GOP based four terminal devices can be used for cost effective, flexible and easy to make stress, strain or force sensors.

  4. 48 CFR 52.247-44 - F.o.b. Designated Air Carrier's Terminal, Point of Importation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false F.o.b. Designated Air... CLAUSES Text of Provisions and Clauses 52.247-44 F.o.b. Designated Air Carrier's Terminal, Point of... the delivery term is f.o.b. designated air carrier's terminal, point of importation: F.o.b. Designated...

  5. 48 CFR 47.303-15 - F.o.b. designated air carrier's terminal, point of exportation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false F.o.b. designated air... Contracts 47.303-15 F.o.b. designated air carrier's terminal, point of exportation. (a) Explanation of delivery term. F.o.b. designated air carrier's terminal, point of exportation means free of expense to the...

  6. 48 CFR 52.247-43 - F.o.b. Designated Air Carrier's Terminal, Point of Exportation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false F.o.b. Designated Air... CLAUSES Text of Provisions and Clauses 52.247-43 F.o.b. Designated Air Carrier's Terminal, Point of... the delivery term is f.o.b. designated air carrier's terminal, point of exportation: F.o.b. Designated...

  7. 48 CFR 47.303-16 - F.o.b. designated air carrier's terminal, point of importation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false F.o.b. designated air... Contracts 47.303-16 F.o.b. designated air carrier's terminal, point of importation. (a) Explanation of delivery term. F.o.b. designated air carrier's terminal, point of importation means free of expense to the...

  8. Three-terminal graphene negative differential resistance devices.

    PubMed

    Wu, Yanqing; Farmer, Damon B; Zhu, Wenjuan; Han, Shu-Jen; Dimitrakopoulos, Christos D; Bol, Ageeth A; Avouris, Phaedon; Lin, Yu-Ming

    2012-03-27

    A new mechanism for negative differential resistance (NDR) is discovered in three-terminal graphene devices based on a field-effect transistor configuration. This NDR effect is a universal phenomenon for graphene and is demonstrated in devices fabricated with different types of graphene materials and gate dielectrics. Operation of conventional NDR devices is usually based on quantum tunneling or intervalley carrier transfer, whereas the NDR behavior observed here is unique to the ambipolar behavior of zero-bandgap graphene and is associated with the competition between electron and hole conduction as the drain bias increases. These three terminal graphene NDR devices offer more operation flexibility than conventional two-terminal devices based on tunnel diodes, Gunn diodes, or molecular devices, and open up new opportunities for graphene in microwave to terahertz applications. © 2012 American Chemical Society

  9. Armored umbilical apparatus for towing a marine seismic air gun sub array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burrage, E.C.

    1985-06-25

    An armored umbilical and termination housing is disclosed for towing a sub-array of seismic air guns used in marine seismic surveying comprising a single air hose for supplying all the high pressure air to the individual air guns surrounded by all the electrical control cables needed to operate the air guns in the sub-array. Protective coatings are applied around the electrical control cables and stress members for carrying the load of towing the sub-array are incorporated within the umbilical. A termination housing is provided on the end of the umbilical for terminating the single air hose and all the electricalmore » control lines to common connectors so that individual electrical control lines and air hoses can run from the termination housing to each individual air gun in the sub-array. Air shut off valves are provided so that the high pressure air can be shut off to the individual air guns within the sub-array remotely from the survey vessel.« less

  10. Detection of radio-frequency modulated optical signals by two and three terminal microwave devices

    NASA Technical Reports Server (NTRS)

    Bhasin, K. B.; Simons, R. N.; Wojtczuk, S.

    1987-01-01

    An interdigitated photoconductor (two terminal device) on GaAlAs/GaAs heterostructure was fabricated and tested by an electro-optical sampling technique. Further, the photoresponse of GaAlAs/GaAs HEMT (three terminal device) was obtained by illuminating the device with an optical signal modulated up to 8 GHz. Gain-bandwidth product, response time, and noise properties of photoconductor and HEMT devices were obtained. Monolithic integration of these photodetectors with GaAs microwave devices for optically controlled phased array antenna applications is discussed.

  11. Effect of a patient engagement tool on positive airway pressure adherence: analysis of a German healthcare provider database.

    PubMed

    Woehrle, Holger; Arzt, Michael; Graml, Andrea; Fietze, Ingo; Young, Peter; Teschler, Helmut; Ficker, Joachim H

    2018-01-01

    This study investigated the addition of a real-time feedback patient engagement tool on positive airway pressure (PAP) adherence when added to a proactive telemedicine strategy. Data from a German healthcare provider (ResMed Healthcare Germany) were retrospectively analyzed. Patients who first started PAP therapy between 1 September 2009 and 30 April 2014, and were managed using telemedicine (AirView™; proactive care) or telemedicine + patient engagement tool (AirView™ + myAir™; patient engagement) were eligible. Patient demographics, therapy start date, sleep-disordered breathing indices, device usage hours, and therapy termination rate were obtained and compared between the two groups. The first 500 patients managed by telemedicine-guided care and a patient engagement tool were matched with 500 patients managed by telemedicine-guided care only. The proportion of nights with device usage ≥4 h was 77 ± 25% in the patient engagement group versus 63 ± 32% in the proactive care group (p < 0.001). Therapy termination occurred less often in the patient engagement group (p < 0.001). The apnea-hypopnea index was similar in the two groups, but leak was significantly lower in the patient engagement versus proactive care group (2.7 ± 4.0 vs 4.1 ± 5.3 L/min; p < 0.001). Addition of a patient engagement tool to telemonitoring-guided proactive care was associated with higher device usage and lower leak. This suggests that addition of an engagement tool may help improve PAP therapy adherence and reduce mask leak. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Capillary zone electrophoresis-mass spectrometer interface

    DOEpatents

    D`Silva, A.

    1996-08-06

    A device for providing equal electrical potential between two loci unconnected by solid or liquid electrical conductors is provided. The device comprises a first electrical conducting terminal, a second electrical conducting terminal connected to the first terminal by a rigid dielectric structure, and an electrically conducting gas contacting the first and second terminals. This device is particularly suitable for application in the electrospray ionization interface between a capillary zone electrophoresis apparatus and a mass spectrometer. 1 fig.

  13. Capillary zone electrophoresis-mass spectrometer interface

    DOEpatents

    D'Silva, Arthur

    1996-08-06

    A device for providing equal electrical potential between two loci unconnected by solid or liquid electrical conducts is provided. The device comprises a first electrical conducting terminal, a second electrical conducting terminal connected to the first terminal by a rigid dielectric structure, and an electrically conducting gas contacting the first and second terminals. This device is particularly suitable for application in the electrospray ionization interface between a capillary zone electrophoresis apparatus and a mass spectrometer.

  14. High-Performance Phototransistors Based on PDIF-CN2 Solution-Processed Single Fiber and Multifiber Assembly.

    PubMed

    Rekab, Wassima; Stoeckel, Marc-Antoine; El Gemayel, Mirella; Gobbi, Marco; Orgiu, Emanuele; Samorì, Paolo

    2016-04-20

    Here we describe the fabrication of organic phototransistors based on either single or multifibers integrated in three-terminal devices. These self-assembled fibers have been produced by solvent-induced precipitation of an air stable and solution-processable perylene di-imide derivative, i.e., PDIF-CN2. The optoelectronic properties of these devices were compared to devices incorporating more disordered spin-coated PDIF-CN2 thin-films. The single-fiber devices revealed significantly higher field-effect mobilities, compared to multifiber and thin-films, exceeding 2 cm(2) V(-1) s(-1). Such an efficient charge transport is the result of strong intermolecular coupling between closely packed PDIF-CN2 molecules and of a low density of structural defects. The improved crystallinity allows efficient collection of photogenerated Frenkel excitons, which results in the highest reported responsivity (R) for single-fiber PDI-based phototransistors, and photosensitivity (P) exceeding 2 × 10(3) AW(-1), and 5 × 10(3), respectively. These findings provide unambiguous evidence for the key role played by the high degree of order at the supramolecular level to leverage the material's properties toward the fabrication of light-sensitive organic field-effect transistors combining a good operational stability, high responsivity and photosensitivity. Our results show also that the air-stability performances are superior in devices where highly crystalline supramolecularly engineered architectures serve as the active layer.

  15. Probing material conductivity in two-terminal devices by resistance difference

    NASA Astrophysics Data System (ADS)

    Lu, Yang; Chen, I.-Wei

    2017-08-01

    It is generally impossible in two-terminal devices to separate the resistance of the device material from the parasitic resistance of terminals, interfaces, and serial loads, yet such information is needed to understand device physics. Here, we present an exact resistance-difference analysis, for a library of similarly configured two-terminal devices with self-similar material responses to external perturbations (electric current, temperature, and magnetic field), to obtain the relative conductivity change Δσ/σ in the device material using device-resistance data only. An outstanding example is nanometallic Mo/Si3N4:Pt/Pt resistance memory, in which electrons in Si3N4:Pt—the device material—display entirely different physics from those in the Pt and Mo electrodes. Our method unraveled their individual Δσ/σ, which for Si3N4:Pt exhibits self-similarity over different resistance states and film thicknesses.

  16. 78 FR 14024 - Energy Efficiency Program for Commercial and Industrial Equipment: Public Meeting and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-04

    ...: Public Meeting and Availability of the Framework Document for Packaged Terminal Air Conditioners and... document for packaged terminal air conditioners and heat pumps. This notice corrects the date of the public... announcement of a public meeting and availability of the framework document for packaged terminal air...

  17. Hole-assisted fiber based fiber fuse terminator supporting 22 W input

    NASA Astrophysics Data System (ADS)

    Tsujikawa, Kyozo; Kurokawa, Kenji; Hanzawa, Nobutomo; Nozoe, Saki; Matsui, Takashi; Nakajima, Kazuhide

    2018-05-01

    We investigated the air hole structure in hole-assisted fiber (HAF) with the aim of terminating fiber fuse propagation. We focused on two structural parameters c/MFD and S1/S2, which are related respectively to the position and area of the air holes, and mapped their appropriate values for terminating fiber fuse propagation. Here, MFD is the mode field diameter, c is the diameter of an inscribed circle linking the air holes, S1 is the total area of the air holes, and S2 is the area of a circumscribed circle linking the air holes. On the basis of these results, we successfully realized a compact fiber fuse terminator consisting of a 1.35 mm-long HAF, which can terminate fiber fuse propagation even with a 22 W input. In addition, we observed fiber fuse termination using a high-speed camera. We additionally confirmed that the HAF-based fiber fuse terminator is effective under various input power conditions. The penetration length of the optical discharge in the HAF was only less than 300 μm when the input power was from 2 to 22 W.

  18. Si light-emitting device in integrated photonic CMOS ICs

    NASA Astrophysics Data System (ADS)

    Xu, Kaikai; Snyman, Lukas W.; Aharoni, Herzl

    2017-07-01

    The motivation for integrated Si optoelectronics is the creation of low-cost photonics for mass-market applications. Especially, the growing demand for sensitive biochemical sensors in the environmental control or medicine leads to the development of integrated high resolution sensors. Here CMOS-compatible Si light-emitting device structures are presented for investigating the effect of various depletion layer profiles and defect engineering on the photonic transition in the 1.4-2.8 eV. A novel Si device is proposed to realize both a two-terminal Si-diode light-emitting device and a three-terminal Si gate-controlled diode light-emitting device in the same device structure. In addition to the spectral analysis, differences between two-terminal and three-terminal devices are discussed, showing the light emission efficiency change. The proposed Si optical source may find potential applications in micro-photonic systems and micro-optoelectro-mechanical systems (MOEMS) in CMOS integrated circuitry.

  19. 14 CFR Special Federal Aviation... - Process for Requesting Waiver of Mandatory Separation Age for a Federal Aviation Administration...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Stations, Enroute or Terminal Facilities, and the David J. Hurley Air Traffic Control System Command Center... Stations, Enroute or Terminal Facilities, and the David J. Hurley Air Traffic Control System Command Center..., enroute facilities, terminal facilities, or at the David J. Hurley Air Traffic Control System Command...

  20. 14 CFR Special Federal Aviation... - Process for Requesting Waiver of Mandatory Separation Age for a Federal Aviation Administration...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Stations, Enroute or Terminal Facilities, and the David J. Hurley Air Traffic Control System Command Center... Stations, Enroute or Terminal Facilities, and the David J. Hurley Air Traffic Control System Command Center..., enroute facilities, terminal facilities, or at the David J. Hurley Air Traffic Control System Command...

  1. 14 CFR Special Federal Aviation... - Process for Requesting Waiver of Mandatory Separation Age for a Federal Aviation Administration...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Stations, Enroute or Terminal Facilities, and the David J. Hurley Air Traffic Control System Command Center... Stations, Enroute or Terminal Facilities, and the David J. Hurley Air Traffic Control System Command Center..., enroute facilities, terminal facilities, or at the David J. Hurley Air Traffic Control System Command...

  2. 14 CFR Special Federal Aviation... - Process for Requesting Waiver of Mandatory Separation Age for a Federal Aviation Administration...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Stations, Enroute or Terminal Facilities, and the David J. Hurley Air Traffic Control System Command Center... Stations, Enroute or Terminal Facilities, and the David J. Hurley Air Traffic Control System Command Center..., enroute facilities, terminal facilities, or at the David J. Hurley Air Traffic Control System Command...

  3. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  4. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  5. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  6. 1. TERMINAL ROOM, INTERIOR, SHOP LEVEL, SHOWING FIRE EXTINGUISHING SYSTEM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. TERMINAL ROOM, INTERIOR, SHOP LEVEL, SHOWING FIRE EXTINGUISHING SYSTEM PIPES AND VALVES AT LEFT. Looking southeast from entrance to terminal room. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  7. Obstacles to the Termination of Air Force Activities.

    DTIC Science & Technology

    1986-04-01

    sugsts how. it the Air Force leadership con- eludes that termination is necessary the Air Force can surmount the obstacles.’ The stud v was cMIduct ed...the Air Force leadership concludes that the termination of a major activity is a promising or necessary management option, the report suggests that it...complicated inter- nal political process; it takes time to work out. The top leadership should begin the process of corporate strategy building and priority

  8. Determining the Terminal Velocity of Wood and Bark Chips

    Treesearch

    John A. Sturos

    1972-01-01

    Designing an efficient air flotation segregator to segregate bark chips from wood chips requires that the terminal velocities be determined for various pulpwood species. The technique described here uses forced air in a vertical wind tunnel with the chip initially at rest on a stationary screen; when the terminal air velocity in reached, the chip begins to float. A...

  9. Electric drive systems including smoothing capacitor cooling devices and systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dede, Ercan Mehmet; Zhou, Feng

    An electric drive system includes a smoothing capacitor including at least one terminal, a bus bar electrically coupled to the at least one terminal, a thermoelectric device including a first side and a second side positioned opposite the first side, where the first side is thermally coupled to at least one of the at least one terminal and the bus bar, and a cooling element thermally coupled to the second side of the thermoelectric device, where the cooling element dissipates heat from the thermoelectric device.

  10. 29 CFR 1917.155 - Air receivers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...

  11. 29 CFR 1917.155 - Air receivers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...

  12. 29 CFR 1917.155 - Air receivers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...

  13. 29 CFR 1917.155 - Air receivers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...

  14. 29 CFR 1917.155 - Air receivers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...

  15. Multi-Directional Environmental Sensors

    NASA Technical Reports Server (NTRS)

    Manohara, Harish (Inventor); Del Castillo, Linda Y. (Inventor); Mojarradi, Mohammed M. (Inventor)

    2016-01-01

    Systems and methods in accordance with embodiments of the invention implement multi-directional environmental sensors. In one embodiment, a multi-directional environmental sensor includes: an inner conductive element that is substantially symmetrical about three orthogonal planes; an outer conductive element that is substantially symmetrical about three orthogonal planes; and a device that measures the electrical characteristics of the multi-directional environmental sensor, the device having a first terminal and a second terminal; where the inner conductive element is substantially enclosed within the outer conductive element; where the inner conductive element is electrically coupled to the first terminal of the device; and where the outer conductive element is electrically coupled to the second terminal of the device.

  16. Magnetization switching schemes for nanoscale three-terminal spintronics devices

    NASA Astrophysics Data System (ADS)

    Fukami, Shunsuke; Ohno, Hideo

    2017-08-01

    Utilizing spintronics-based nonvolatile memories in integrated circuits offers a promising approach to realize ultralow-power and high-performance electronics. While two-terminal devices with spin-transfer torque switching have been extensively developed nowadays, there has been a growing interest in devices with a three-terminal structure. Of primary importance for applications is the efficient manipulation of magnetization, corresponding to information writing, in nanoscale devices. Here we review the studies of current-induced domain wall motion and spin-orbit torque-induced switching, which can be applied to the write operation of nanoscale three-terminal spintronics devices. For domain wall motion, the size dependence of device properties down to less than 20 nm will be shown and the underlying mechanism behind the results will be discussed. For spin-orbit torque-induced switching, factors governing the threshold current density and strategies to reduce it will be discussed. A proof-of-concept demonstration of artificial intelligence using an analog spin-orbit torque device will also be reviewed.

  17. 42 CFR 136.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... pregnancies. 136.55 Section 136.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices to... an ectopic pregnancy. ...

  18. 42 CFR 136.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pregnancies. 136.55 Section 136.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices to... an ectopic pregnancy. ...

  19. 42 CFR 136.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... pregnancies. 136.55 Section 136.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices to... an ectopic pregnancy. ...

  20. 42 CFR 136.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... pregnancies. 136.55 Section 136.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices to... an ectopic pregnancy. ...

  1. 42 CFR 136.55 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... pregnancies. 136.55 Section 136.55 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... devices and termination of ectopic pregnancies. Federal funds are available for drugs or devices to... an ectopic pregnancy. ...

  2. 14 CFR 272.12 - Termination.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS ESSENTIAL AIR SERVICE TO THE FREELY ASSOCIATED STATES § 272.12 Termination. These provisions shall terminate on October 1, 1998, unless the program of essential air service to the Federated States of...

  3. Bidirectional buck boost converter

    DOEpatents

    Esser, Albert Andreas Maria

    1998-03-31

    A bidirectional buck boost converter and method of operating the same allows regulation of power flow between first and second voltage sources in which the voltage level at each source is subject to change and power flow is independent of relative voltage levels. In one embodiment, the converter is designed for hard switching while another embodiment implements soft switching of the switching devices. In both embodiments, first and second switching devices are serially coupled between a relatively positive terminal and a relatively negative terminal of a first voltage source with third and fourth switching devices serially coupled between a relatively positive terminal and a relatively negative terminal of a second voltage source. A free-wheeling diode is coupled, respectively, in parallel opposition with respective ones of the switching devices. An inductor is coupled between a junction of the first and second switching devices and a junction of the third and fourth switching devices. Gating pulses supplied by a gating circuit selectively enable operation of the switching devices for transferring power between the voltage sources. In the second embodiment, each switching device is shunted by a capacitor and the switching devices are operated when voltage across the device is substantially zero.

  4. Bidirectional buck boost converter

    DOEpatents

    Esser, A.A.M.

    1998-03-31

    A bidirectional buck boost converter and method of operating the same allows regulation of power flow between first and second voltage sources in which the voltage level at each source is subject to change and power flow is independent of relative voltage levels. In one embodiment, the converter is designed for hard switching while another embodiment implements soft switching of the switching devices. In both embodiments, first and second switching devices are serially coupled between a relatively positive terminal and a relatively negative terminal of a first voltage source with third and fourth switching devices serially coupled between a relatively positive terminal and a relatively negative terminal of a second voltage source. A free-wheeling diode is coupled, respectively, in parallel opposition with respective ones of the switching devices. An inductor is coupled between a junction of the first and second switching devices and a junction of the third and fourth switching devices. Gating pulses supplied by a gating circuit selectively enable operation of the switching devices for transferring power between the voltage sources. In the second embodiment, each switching device is shunted by a capacitor and the switching devices are operated when voltage across the device is substantially zero. 20 figs.

  5. 21 CFR 810.17 - Termination of a cease distribution and notification or mandatory recall order.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... that they have been instructed to cease use of the device and to take other appropriate action; or (2..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE RECALL AUTHORITY Mandatory Medical Device Recall Procedures § 810.17 Termination of a cease distribution and notification or...

  6. GRC-2011-C-03754

    NASA Image and Video Library

    2007-09-26

    Molecular Electronics; Polymeric Films; Two-Terminal and Three-Terminal Devices Intended for the Development and/or Demonstration of Molecular Electronics Devices such as Field Effect Transistors, FETs

  7. 42 CFR 441.207 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... pregnancies. 441.207 Section 441.207 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... APPLICABLE TO SPECIFIC SERVICES Abortions § 441.207 Drugs and devices and termination of ectopic pregnancies... and for medical procedures necessary for the termination of an ectopic pregnancy. ...

  8. 42 CFR 441.207 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... pregnancies. 441.207 Section 441.207 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... APPLICABLE TO SPECIFIC SERVICES Abortions § 441.207 Drugs and devices and termination of ectopic pregnancies... and for medical procedures necessary for the termination of an ectopic pregnancy. ...

  9. 42 CFR 441.207 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... pregnancies. 441.207 Section 441.207 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... APPLICABLE TO SPECIFIC SERVICES Abortions § 441.207 Drugs and devices and termination of ectopic pregnancies... and for medical procedures necessary for the termination of an ectopic pregnancy. ...

  10. 42 CFR 441.207 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pregnancies. 441.207 Section 441.207 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... APPLICABLE TO SPECIFIC SERVICES Abortions § 441.207 Drugs and devices and termination of ectopic pregnancies... and for medical procedures necessary for the termination of an ectopic pregnancy. ...

  11. 42 CFR 441.207 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... pregnancies. 441.207 Section 441.207 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF... APPLICABLE TO SPECIFIC SERVICES Abortions § 441.207 Drugs and devices and termination of ectopic pregnancies... and for medical procedures necessary for the termination of an ectopic pregnancy. ...

  12. 4. NORTH END OF TERMINAL ROOM, SHOP LEVEL SHOWING SPIRAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. NORTH END OF TERMINAL ROOM, SHOP LEVEL SHOWING SPIRAL STAIR TO CABLE RACK. Looking north. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  13. 2. TERMINAL ROOM, SHOP LEVEL INTERIOR, SHOWING MEZZANINE LEVEL CABLE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. TERMINAL ROOM, SHOP LEVEL INTERIOR, SHOWING MEZZANINE LEVEL CABLE RACK AT UPPER RIGHT. Looking north. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  14. Enhanced surface transfer doping of diamond by V{sub 2}O{sub 5} with improved thermal stability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, Kevin G., E-mail: k.crawford.2@research.gla.ac.uk; Moran, David A. J.; Cao, Liang

    2016-01-25

    Surface transfer doping of hydrogen-terminated diamond has been achieved utilising V{sub 2}O{sub 5} as a surface electron accepting material. Contact between the oxide and diamond surface promotes the transfer of electrons from the diamond into the V{sub 2}O{sub 5} as revealed by the synchrotron-based high resolution photoemission spectroscopy. Electrical characterization by Hall measurement performed before and after V{sub 2}O{sub 5} deposition shows an increase in hole carrier concentration in the diamond from 3.0 × 10{sup 12} to 1.8 × 10{sup 13 }cm{sup −2} at room temperature. High temperature Hall measurements performed up to 300 °C in atmosphere reveal greatly enhanced thermal stability of the hole channelmore » produced using V{sub 2}O{sub 5} in comparison with an air-induced surface conduction channel. Transfer doping of hydrogen-terminated diamond using high electron affinity oxides such as V{sub 2}O{sub 5} is a promising approach for achieving thermally stable, high performance diamond based devices in comparison with air-induced surface transfer doping.« less

  15. Terminal Air Flow Planning

    NASA Technical Reports Server (NTRS)

    Denery, Dallas G.; Erzberger, Heinz; Edwards, Thomas A. (Technical Monitor)

    1998-01-01

    The Center TRACON Automation System (CTAS) will be the basis for air traffic planning and control in the terminal area. The system accepts arriving traffic within an extended terminal area and optimizes the flow based on current traffic and airport conditions. The operational use of CTAS will be presented together with results from current operations.

  16. Assessment of body-powered upper limb prostheses by able-bodied subjects, using the Box and Blocks Test and the Nine-Hole Peg Test.

    PubMed

    Haverkate, Liz; Smit, Gerwin; Plettenburg, Dick H

    2016-02-01

    The functional performance of currently available body-powered prostheses is unknown. The goal of this study was to objectively assess and compare the functional performance of three commonly used body-powered upper limb terminal devices. Experimental trial. A total of 21 able-bodied subjects (n = 21, age = 22 ± 2) tested three different terminal devices: TRS voluntary closing Hook Grip 2S, Otto Bock voluntary opening hand and Hosmer Model 5XA hook, using a prosthesis simulator. All subjects used each terminal device nine times in two functional tests: the Nine-Hole Peg Test and the Box and Blocks Test. Significant differences were found between the different terminal devices and their scores on the Nine-Hole Peg Test and the Box and Blocks Test. The Hosmer hook scored best in both tests. The TRS Hook Grip 2S scored second best. The Otto Bock hand showed the lowest scores. This study is a first step in the comparison of functional performances of body-powered prostheses. The data can be used as a reference value, to assess the performance of a terminal device or an amputee. The measured scores enable the comparison of the performance of a prosthesis user and his or her terminal device relative to standard scores. © The International Society for Prosthetics and Orthotics 2014.

  17. 19. DETAIL OF AIR FORCE WEATHER INFORMATION TERMINAL AND CHART ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. DETAIL OF AIR FORCE WEATHER INFORMATION TERMINAL AND CHART RECORDER LOCATED IMMEDIATELY NORTH OF CONSOLE IN PHOTOS A-15 THROUGH A-18. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. Aerospace Ground Equipment for model 4080 sequence programmer. A standard computer terminal is adapted to provide convenient operator to device interface

    NASA Technical Reports Server (NTRS)

    Nissley, L. E.

    1979-01-01

    The Aerospace Ground Equipment (AGE) provides an interface between a human operator and a complete spaceborne sequence timing device with a memory storage program. The AGE provides a means for composing, editing, syntax checking, and storing timing device programs. The AGE is implemented with a standard Hewlett-Packard 2649A terminal system and a minimum of special hardware. The terminal's dual tape interface is used to store timing device programs and to read in special AGE operating system software. To compose a new program for the timing device the keyboard is used to fill in a form displayed on the screen.

  19. Resonant tunneling based graphene quantum dot memristors.

    PubMed

    Pan, Xuan; Skafidas, Efstratios

    2016-12-08

    In this paper, we model two-terminal all graphene quantum dot (GQD) based resistor-type memory devices (memristors). The resistive switching is achieved by resonant electron tunneling. We show that parallel GQDs can be used to create multi-state memory circuits. The number of states can be optimised with additional voltage sources, whilst the noise margin for each state can be controlled by appropriately choosing the branch resistance. A three-terminal GQD device configuration is also studied. The addition of an isolated gate terminal can be used to add further or modify the states of the memory device. The proposed devices provide a promising route towards volatile memory devices utilizing only atomically thin two-dimensional graphene.

  20. Three-terminal resistive switching memory in a transparent vertical-configuration device

    NASA Astrophysics Data System (ADS)

    Ungureanu, Mariana; Llopis, Roger; Casanova, Fèlix; Hueso, Luis E.

    2014-01-01

    The resistive switching phenomenon has attracted much attention recently for memory applications. It describes the reversible change in the resistance of a dielectric between two non-volatile states by the application of electrical pulses. Typical resistive switching memories are two-terminal devices formed by an oxide layer placed between two metal electrodes. Here, we report on the fabrication and operation of a three-terminal resistive switching memory that works as a reconfigurable logic component and offers an increased logic density on chip. The three-terminal memory device we present is transparent and could be further incorporated in transparent computing electronic technologies.

  1. Optical control system for high-voltage terminals

    DOEpatents

    Bicek, John J.

    1978-01-01

    An optical control system for the control of devices in the terminal of an electrostatic accelerator includes a laser that is modulated by a series of preselected codes produced by an encoder. A photodiode receiver is placed in the laser beam at the high-voltage terminal of an electrostatic accelerator. A decoder connected to the photodiode decodes the signals to provide control impulses for a plurality of devices at the high voltage of the terminal.

  2. Air Conditioning. Performance Objectives. Intermediate Course.

    ERIC Educational Resources Information Center

    Long, William

    Several intermediate performance objectives and corresponding criterion measures are listed for each of seven terminal objectives for an intermediate air conditioning course. The titles of the seven terminal objectives are Refrigeration Cycle, Job Requirement Skills, Air Conditioning, Trouble Shooting, Performance Test, Shop Management, and S.I.E.…

  3. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be protected by chip guarding and personal protective equipment complying with the provisions of subpart E of...

  4. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be protected by chip guarding and personal protective equipment complying with the provisions of subpart E of...

  5. FAA (Federal Aviation Administration) Statistical Handbook of Aviation, Calendar Year 1983.

    DTIC Science & Technology

    1984-12-31

    terminal and en route air traffic activity information (i.e., operations, flight plans filed) of the National Airspace System. The data is from the FAA...reflecting the fiscal and calendar year workload of the FAA air traffic facilities--terminal and en route-- are contained in Chapter II. This chapter...V, 4JW -v- A I.., r- >9 c U).)I .4 F- %. II. The National Airspace System This chapter furnishes terminal and en route air traffic activity

  6. 21 CFR 830.220 - Termination of FDA service as an issuing agency.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Termination of FDA service as an issuing agency... SERVICES (CONTINUED) MEDICAL DEVICES UNIQUE DEVICE IDENTIFICATION FDA as an Issuing Agency § 830.220 Termination of FDA service as an issuing agency. (a) FDA may end our services as an issuing agency if we...

  7. Telephone equipment room, showing channel terminal bank with vacuum tubes. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Telephone equipment room, showing channel terminal bank with vacuum tubes. View to east - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  8. Relative air temperature analysis external building on Gowa Campus

    NASA Astrophysics Data System (ADS)

    Mustamin, Tayeb; Rahim, Ramli; Baharuddin; Jamala, Nurul; Kusno, Asniawaty

    2018-03-01

    This study aims to data analyze the relative temperature and humidity of the air outside the building. Data retrieval taken from weather monitoring device (monitoring) Vaisala, RTU (Remote Terminal Unit), Which is part of the AWS (Automatic Weather Stations) Then Processing data processed and analyzed by using Microsoft Excel program in the form of graph / picture fluctuation Which shows the average value, standard deviation, maximum value, and minimum value. Results of data processing then grouped in the form: Daily, and monthly, based on time intervals every 30 minutes. The results showed Outside air temperatures in March, April, May and September 2016 Which entered in the thermal comfort zone according to SNI standard (Indonesian National Standard) only at 06.00-10.00. In late March to early April Thermal comfort zone also occurs at 15.30-18.00. The highest maximum air temperature occurred in September 2016 at 11.01-11.30 And the lowest minimum value in September 2016, time 6:00 to 6:30. The result of the next analysis shows the level of data conformity with thermal comfort zone based on SNI (Indonesian National Standard) every month.

  9. The portable device for continual measurement of radon progenies on filter using the detector Timepix.

    PubMed

    Bulanek, Boris; Hulka, Jiri; Jilek, Karel; Stekl, Ivan

    2015-06-01

    In this article, a portable device was presented for continual measuring of equilibrium equivalent concentration (EEC) of (222)Rn based on the Timepix detector with 300-µm-thick active layer. In order to have a portable device, a filtration head was developed for collecting short-lived radon progenies attached on aerosols. The short-lived progenies are estimated from analysing alphas from decay of (218,214)Po from Millipore filter after termination of filtration. Comparison with beta measurement was done as well. The dependence of EEC on an air flow and filtration time was studied. The low-level detection limit for EEC was estimated from the last 10 min of 3-h decay measurement and was found in the range of 40-70 Bq m(-3). EEC was measured in National Radiation Protection Institute radon chamber, and results were compared with the commercial detector Fritra4. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Reducing leakage current in semiconductor devices

    DOEpatents

    Lu, Bin; Matioli, Elison de Nazareth; Palacios, Tomas Apostol

    2018-03-06

    A semiconductor device includes a first region having a first semiconductor material and a second region having a second semiconductor material. The second region is formed over the first region. The semiconductor device also includes a current blocking structure formed in the first region between first and second terminals of the semiconductor device. The current blocking structure is configured to reduce current flow in the first region between the first and second terminals.

  11. Performance evaluation and comparison of three-terminal energy selective electron devices with different connective ways and filter configurations

    NASA Astrophysics Data System (ADS)

    Peng, Wanli; Zhang, Yanchao; Yang, Zhimin; Chen, Jincan

    2018-02-01

    Three-terminal energy selective electron (ESE) devices consisting of three electronic reservoirs connected by two energy filters and an electronic conductor with negligible resistance may work as ESE refrigerators and amplifiers. They have three possible connective ways for the electronic conductor and six electronic transmission forms. The configuration of energy filters may be described by the different transmission functions such as the rectangular and Lorentz transmission functions. The ESE devices with three connective ways can be, respectively, regarded as three equivalent hybrid systems composed of an ESE heat engine and an ESE refrigerator/heat pump. With the help of the theory of the ESE devices operated between two electronic reservoirs, the coefficients of performance and cooling rates (heat-pumping rates) of hybrid systems are directly derived. The general performance characteristics of hybrid systems are revealed. The optimal regions of these devices are determined. The performances of the devices with three connective ways of the electronic conductor and two configurations of energy filters are compared in detail. The advantages and disadvantages of each of three-terminal ESE devices are expounded. The results obtained here may provide some guidance for the optimal design and operation of three-terminal ESE devices.

  12. Cut Bank Municipal Airport and Army Air Force Base, Terminal ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Cut Bank Municipal Airport and Army Air Force Base, Terminal Building, Approximately 390 yards west of Valier Highway (Montana Route 358), three miles southwest of Cut Bank, Cut Bank, Glacier County, MT

  13. Complementary Paired G4FETs as Voltage-Controlled NDR Device

    NASA Technical Reports Server (NTRS)

    Mojarradi, Mohammad; Chen, Suheng; Blalock, Ben; Britton, Chuck; Prothro, Ben; Vandersand, James; Schrimph, Ron; Cristoloveanu, Sorin; Akavardar, Kerem; Gentil, P.

    2009-01-01

    It is possible to synthesize a voltage-controlled negative-differential-resistance (NDR) device or circuit by use of a pair of complementary G4FETs (four-gate field-effect transistors). [For more information about G4FETs, please see the immediately preceding article]. As shown in Figure 1, the present voltage-controlled NDR device or circuit is an updated version of a prior NDR device or circuit, known as a lambda diode, that contains a pair of complementary junction field-effect transistors (JFETs). (The lambda diode is so named because its current-versus- voltage plot bears some resemblance to an upper-case lambda.) The present version can be derived from the prior version by substituting G4FETs for the JFETs and connecting both JFET gates of each G4FET together. The front gate terminals of the G4FETs constitute additional terminals (that is, terminals not available in the older JFET version) to which one can apply control voltages VN and VP. Circuits in which NDR devices have been used include (1) Schmitt triggers and (2) oscillators containing inductance/ capacitance (LC) resonant circuits. Figure 2 depicts such circuits containing G4FET NDR devices like that of Figure 1. In the Schmitt trigger shown here, the G4FET NDR is loaded with an ordinary inversion-mode, p-channel, metal oxide/semiconductor field-effect transistor (inversion-mode PMOSFET), the VN terminal of the G4FET NDR device is used as an input terminal, and the input terminals of the PMOSFET and the G4FET NDR device are connected. VP can be used as an extra control voltage (that is, a control voltage not available in a typical prior Schmitt trigger) for adjusting the pinch-off voltage of the p-channel G4FET and thereby adjusting the trigger-voltage window. In the oscillator, a G4FET NDR device is loaded with a conventional LC tank circuit. As in other LC NDR oscillators, oscillation occurs because the NDR counteracts the resistance in the tank circuit. The advantage of this G4FET-NDR LC oscillator over a conventional LC NDR oscillator is that one can apply a time-varying signal to one of the extra control input terminals (VN or VP) to modulate the conductance of the NDR device and thereby amplitude-modulate the output signal.

  14. Installation restoration program. Decision document for soil and groundwater at the storage area at the USMC Subleased Area, Site 3. 144th Fighter Wing, California Air National Guard, Fresno Air Terminal, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-01-01

    Decision Document for IRP Site No. 3 - Storage Area at the USMC Sublease Area, California Air National Guard, 144th Fighter Wing, Fresno Air Terminal, Fresno, California. This report documents the data, conclusion, and recommendation to support a No Further Remedial Action Planned decision at Site 3 under the IRP.

  15. Controller evaluation of initial data link terminal air traffic control services : final report

    DOT National Transportation Integrated Search

    1991-01-01

    This document details the results the first Federal Aviation Administration : Technical Center investigation of the initial terminal air traffic control : services developed for transmission using Data Link technology. Initial Data : Link services we...

  16. Critically safe volume vacuum pickup for use in wet or dry cleanup of radioactive enclosures

    DOEpatents

    Zeren, J.D.

    1993-12-28

    A physical compact vacuum pickup device of critically safe volume and geometric shape is provided for use in radioactive enclosures, such as a small glove box, to facilitate manual cleanup of either wet or dry radioactive material. The device is constructed and arranged so as to remain safe when filled to capacity with plutonium-239 oxide. Two fine mesh filter bags are supported on the exterior of a rigid fine mesh stainless steel cup. This assembly is sealed within, and spaced from, the interior walls of a stainless steel canister. An air inlet communicates with the interior of the canister. A modified conventional vacuum head is physically connected to, and associated with, the interior of the mesh cup. The volume of the canister, as defined by the space between the mesh cup and the interior walls of the canister, forms a critically safe volume and geometric shape for dry radioactive particles that are gathered within the canister. A critically safe liquid volume is maintained by operation of a suction terminating float valve, and/or by operation of redundant vacuum check/liquid drain valves and placement of the air inlet. 5 figures.

  17. Critically safe volume vacuum pickup for use in wet or dry cleanup of radioactive enclosures

    DOEpatents

    Zeren, Joseph D.

    1993-12-28

    A physical compact vacuum pickup device of critically safe volume and geometric shape is provided for use in radioactive enclosures, such as a small glove box, to facilitate manual cleanup of either wet or dry radioactive material. The device is constructed and arranged so as to remain safe when filled to capacity with plutonium-239 oxide. Two fine mesh filter bags are supported on the exterior of a rigid fine mesh stainless steel cup. This assembly is sealed within, and spaced from, the interior walls of a stainless steel canister. An air inlet communicates with the interior of the canister. A modified conventional vacuum head is physically connected to, and associated with, the interior of the mesh cup. The volume of the canister, as defined by the space between the mesh cup and the interior walls of the canister, forms a critically safe volume and geometric shape for dry radioactive particles that are gathered within the canister. A critically safe liquid volume is maintained by operation of a suction terminating float valve, and/or by operation of redundant vacuum check/liquid drain valves and placement of the air inlet.

  18. 47 CFR 15.115 - TV interface devices, including cable system terminal devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... times the square root of (R) for the video signal and 155 times the square root of (R) for the audio... and 77.5 times the square root of (R) for the audio signal. (2) At any RF output terminal, the maximum... video cassette recorders continue to be subject to the provisions for general TV interface devices. (c...

  19. 47 CFR 15.115 - TV interface devices, including cable system terminal devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... times the square root of (R) for the video signal and 155 times the square root of (R) for the audio... and 77.5 times the square root of (R) for the audio signal. (2) At any RF output terminal, the maximum... video cassette recorders continue to be subject to the provisions for general TV interface devices. (c...

  20. 47 CFR 15.115 - TV interface devices, including cable system terminal devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... times the square root of (R) for the video signal and 155 times the square root of (R) for the audio... and 77.5 times the square root of (R) for the audio signal. (2) At any RF output terminal, the maximum... video cassette recorders continue to be subject to the provisions for general TV interface devices. (c...

  1. A new approach for two-terminal electronic memory devices - Storing information on silicon nanowires

    NASA Astrophysics Data System (ADS)

    Saranti, Konstantina; Alotaibi, Sultan; Paul, Shashi

    2016-06-01

    The work described in this paper focuses on the utilisation of silicon nanowires as the information storage element in flash-type memory devices. Silicon nanostructures have attracted attention due to interesting electrical and optical properties, and their potential integration into electronic devices. A detailed investigation of the suitability of silicon nanowires as the charge storage medium in two-terminal non-volatile memory devices are presented in this report. The deposition of the silicon nanostructures was carried out at low temperatures (less than 400 °C) using a previously developed a novel method within our research group. Two-terminal non-volatile (2TNV) memory devices and metal-insulator-semiconductor (MIS) structures containing the silicon nanowires were fabricated and an in-depth study of their characteristics was carried out using current-voltage and capacitance techniques.

  2. 40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... initial air pollution control device inspection? (a) The initial air pollution control device inspection... startup. (b) Within 10 operating days following an air pollution control device inspection, all necessary...

  3. 40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... initial air pollution control device inspection? (a) The initial air pollution control device inspection... startup. (b) Within 10 operating days following an air pollution control device inspection, all necessary...

  4. Design of temperature detection device for drum of belt conveyor

    NASA Astrophysics Data System (ADS)

    Zhang, Li; He, Rongjun

    2018-03-01

    For difficult wiring and big measuring error existed in the traditional temperature detection method for drum of belt conveyor, a temperature detection device for drum of belt conveyor based on Radio Frequency(RF) communication is designed. In the device, detection terminal can collect temperature data through tire pressure sensor chip SP370 which integrates temperature detection and RF emission. The receiving terminal which is composed of RF receiver chip and microcontroller receives the temperature data and sends it to Controller Area Network(CAN) bus. The test results show that the device meets requirements of field application with measuring error ±3.73 ° and single button battery can provide continuous current for the detection terminal over 1.5 years.

  5. Human factors in aviation: Terminal control area boundary conflicts

    NASA Technical Reports Server (NTRS)

    Monan, William P.

    1989-01-01

    Air-to-air conflicts in the vicinity of Terminal Control Area (TCA) boundaries were studied to obtain a better understanding of the causal dynamics of these events with particular focus on human factor issues. The study dataset consisted of 381 Instrument Flight Rules/Visual Flight Rules (IFR/VFR) traffic conflicts in airspace layers above TCA ceiling and below TCA floors; 213 reports of incursions in TCA terminal airspace by VFR aircraft, of which 123 resulted in conflicts; and an additional set of reports describing problems with Air Traffic Control (ATC) services in and around TCAs. Results and conclusions are detailed.

  6. Terminating Devices in Spoken French.

    ERIC Educational Resources Information Center

    Andrews, Barry J.

    1989-01-01

    A study examines the way in which one group of discourse connectors, terminators, function in contemporary spoken French. Three types of terminators, elements used at the end of an utterance or section to indicate its completion, are investigated, including utterance terminators, interrogative tags, and terminal tags. (Author/MSE)

  7. Minimum airflow reset of single-duct VAV terminal boxes

    NASA Astrophysics Data System (ADS)

    Cho, Young-Hum

    Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and applied to actual systems for performance validation. The results of the theoretical analysis, numeric simulations, and experiments show that the optimal control algorithms can automatically identify the minimum rate of heating airflow under actual working conditions. Improved control helps to stabilize room air temperatures. The vertical difference in the room air temperature was lower than the comfort value. Measurements of room CO2 levels indicate that when the minimum airflow set point was reduced it did not adversely affect the indoor air quality. According to the measured energy results, optimal control algorithms give a lower rate of reheating energy consumption than conventional controls.

  8. 76 FR 73677 - Investigations: Terminations, Modifications and Rulings: Certain Electronic Devices With Image...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-29

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-724] Investigations: Terminations, Modifications and Rulings: Certain Electronic Devices With Image Processing Systems, Components Thereof, and Associated Software AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby...

  9. On atomic mechanisms governing the oxidation of Bi2Te3.

    PubMed

    Music, Denis; Chang, Keke; Schmidt, Paul; Braun, Felix N; Heller, Martin; Hermsen, Steffen; Pöllmann, Peter J; Schulzendorff, Till; Wagner, Cedric

    2017-11-09

    Oxidation of Bi 2 Te 3 (space group R [Formula: see text] m) has been investigated using experimental and theoretical means. Based on calorimetry, x-ray photoelectron spectroscopy and thermodynamic modelling, Bi 2 Te 3 is at equilibrium with Bi 2 O 3 and TeO 2 , whereby the most stable compound is Bi 2 Te 3 , followed by Bi 2 O 3 . The reactivity of Bi towards oxygen is expected to be higher than that of Te. This notion is supported by density functional theory. The strongest bond is formed between Bi and Te, followed by Bi-O. This gives rise to unanticipated atomic processes. Dissociatively adsorbed oxygen diffuses through Bi and Te basal planes of Bi 2 Te 3 (0 0 0 1) and preferably interacts with Bi. The Te termination considerably retards this process. These findings may clarify conflicting literature data. Any basal plane off-cut or Bi terminations trigger oxidation, but a perfect basal cleavage, where only Te terminations are exposed to air, may be stable for a longer period of time. These results are of relevance for applications in which surfaces are of key importance, such as nanostructured Bi 2 Te 3 thermoelectric devices.

  10. On atomic mechanisms governing the oxidation of Bi2Te3

    NASA Astrophysics Data System (ADS)

    Music, Denis; Chang, Keke; Schmidt, Paul; Braun, Felix N.; Heller, Martin; Hermsen, Steffen; Pöllmann, Peter J.; Schulzendorff, Till; Wagner, Cedric

    2017-12-01

    Oxidation of Bi2Te3 (space group R \\overline{3} m) has been investigated using experimental and theoretical means. Based on calorimetry, x-ray photoelectron spectroscopy and thermodynamic modelling, Bi2Te3 is at equilibrium with Bi2O3 and TeO2, whereby the most stable compound is Bi2Te3, followed by Bi2O3. The reactivity of Bi towards oxygen is expected to be higher than that of Te. This notion is supported by density functional theory. The strongest bond is formed between Bi and Te, followed by Bi-O. This gives rise to unanticipated atomic processes. Dissociatively adsorbed oxygen diffuses through Bi and Te basal planes of Bi2Te3(0 0 0 1) and preferably interacts with Bi. The Te termination considerably retards this process. These findings may clarify conflicting literature data. Any basal plane off-cut or Bi terminations trigger oxidation, but a perfect basal cleavage, where only Te terminations are exposed to air, may be stable for a longer period of time. These results are of relevance for applications in which surfaces are of key importance, such as nanostructured Bi2Te3 thermoelectric devices.

  11. Controller Evaluation of Initial Data Link Terminal Air Traffic Control Services: Mini Study 2, Volume 1

    DOT National Transportation Integrated Search

    1992-04-01

    This document details the results of the second Mini Study of the Federal : Aviation Administration (FAA)Technical Center investigation and development of : initial terminal air traffic control (ATC) services for transmission using Data : Link techno...

  12. Controller evaluation of initial terminal data link ATC services : mini study 3 : final report

    DOT National Transportation Integrated Search

    1992-12-01

    This report documents the third Federal Aviation Administration (FAA) controller : evaluation of an initial group of four terminal air traffic control (ATC) : services and functions which are under development for implementation on a Data : Link air-...

  13. 78 FR 70320 - Certain Mobile Handset Devices and Related Touch Keyboard Software; Commission Determination Not...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-25

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-864] Certain Mobile Handset Devices and Related Touch Keyboard Software; Commission Determination Not To Review an Initial Determination Terminating the Investigation; Termination of the Investigation AGENCY: U.S. International Trade Commission...

  14. Evaluation of Efficiency Improvement in Vital Documentation Using RFID Devices.

    PubMed

    Kimura, Eizen; Nakai, Miho; Ishihara, Ken

    2016-01-01

    We introduced medical devices with RFID tags and the terminal with RFID reader in our hospital. Time study was conducted in two phases. In phase I, nurses round as usual, and in phase II, the nurse round the ward with a terminal installed on a cart. This study concluded that RFID system shortens the time for vital sign documentation. However, deploying the terminals at every bedside did not contribute the more time reduction.

  15. Application of nanomaterials in two-terminal resistive-switching memory devices

    PubMed Central

    Ouyang, Jianyong

    2010-01-01

    Nanometer materials have been attracting strong attention due to their interesting structure and properties. Many important practical applications have been demonstrated for nanometer materials based on their unique properties. This article provides a review on the fabrication, electrical characterization, and memory application of two-terminal resistive-switching devices using nanomaterials as the active components, including metal and semiconductor nanoparticles (NPs), nanotubes, nanowires, and graphenes. There are mainly two types of device architectures for the two-terminal devices with NPs. One has a triple-layer structure with a metal film sandwiched between two organic semiconductor layers, and the other has a single polymer film blended with NPs. These devices can be electrically switched between two states with significant different resistances, i.e. the ‘ON’ and ‘OFF’ states. These render the devices important application as two-terminal non-volatile memory devices. The electrical behavior of these devices can be affected by the materials in the active layer and the electrodes. Though the mechanism for the electrical switches has been in argument, it is generally believed that the resistive switches are related to charge storage on the NPs. Resistive switches were also observed on crossbars formed by nanotubes, nanowires, and graphene ribbons. The resistive switches are due to nanoelectromechanical behavior of the materials. The Coulombic interaction of transient charges on the nanomaterials affects the configurable gap of the crossbars, which results into significant change in current through the crossbars. These nanoelectromechanical devices can be used as fast-response and high-density memory devices as well. PMID:22110862

  16. Practical color vision tests for air traffic control applicants : en route center and terminal facilities.

    DOT National Transportation Integrated Search

    1995-04-01

    Two practical color vision tests were developed and validated for use in screening Air Traffic Control specialist (ATCS) applicants for work at en route center or terminal facilities. The development of the tests involved careful reproduction/simulat...

  17. 14 CFR 1300.22 - Termination of obligations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Termination of obligations. 1300.22 Section 1300.22 Aeronautics and Space AIR TRANSPORTATION SYSTEM STABILIZATION OFFICE OF MANAGEMENT AND BUDGET AVIATION DISASTER RELIEF-AIR CARRIER GUARANTEE LOAN PROGRAM Minimum Requirements and Application Procedures...

  18. 11. "INSTRUMENTATION AND CONTROL SYSTEMS, EQUIPMENT LOCATION, TEST STAND TERMINAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. "INSTRUMENTATION AND CONTROL SYSTEMS, EQUIPMENT LOCATION, TEST STAND TERMINAL ROOM, PLANS AND SECTION." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 106 of 148; file no. 1321/57. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  19. Design and characterization of a three-terminal transcriptional device through polymerase per second.

    PubMed

    Varadarajan, Prasanna Amur; Del Vecchio, Domitilla

    2009-09-01

    In this paper, we provide an in silico input-output characterization of a three-terminal transcriptional device employing polymerase per second (PoPS) as input and output. The device is assembled from well-characterized parts of the bacteriophage lambda switch transcriptional circuit. We draw the analogy between voltage and protein concentration and between current and PoPS to demonstrate that the characteristics of the three-terminal transcriptional device are qualitatively similar to those of a bipolar junction transistor (BJT). In particular, as it occurs in a BJT, the device can be tuned to operate either as a linear amplifier or as a switch. When the device operates as a linear amplifier, gains of twofolds can be obtained, which are considerably smaller than those obtained in a BJT (in which 100-fold amplification gains can be reached). This fact suggests that the parts extracted from natural transcriptional systems may be naturally designed mostly to process and store information as opposed to amplify signals.

  20. Nonvolatile Ionic Two-Terminal Memory Device

    NASA Technical Reports Server (NTRS)

    Williams, Roger M.

    1990-01-01

    Conceptual solid-state memory device nonvolatile and erasable and has only two terminals. Proposed device based on two effects: thermal phase transition and reversible intercalation of ions. Transfer of sodium ions between source of ions and electrical switching element increases or decreases electrical conductance of element, turning switch "on" or "off". Used in digital computers and neural-network computers. In neural networks, many small, densely packed switches function as erasable, nonvolatile synaptic elements.

  1. Coordinated Parallel Runway Approaches

    NASA Technical Reports Server (NTRS)

    Koczo, Steve

    1996-01-01

    The current air traffic environment in airport terminal areas experiences substantial delays when weather conditions deteriorate to Instrument Meteorological Conditions (IMC). Expected future increases in air traffic will put additional pressures on the National Airspace System (NAS) and will further compound the high costs associated with airport delays. To address this problem, NASA has embarked on a program to address Terminal Area Productivity (TAP). The goals of the TAP program are to provide increased efficiencies in air traffic during the approach, landing, and surface operations in low-visibility conditions. The ultimate goal is to achieve efficiencies of terminal area flight operations commensurate with Visual Meteorological Conditions (VMC) at current or improved levels of safety.

  2. Four-terminal electrical testing device. [initiator bridgewire resistance

    NASA Technical Reports Server (NTRS)

    Robinson, Robert L. (Inventor); Graves, Thomas J. (Inventor); Hoffman, William C., III (Inventor)

    1987-01-01

    The invention relates to a four-terminal electrical connector device for testing and measuring unknown resistances of initiators used for starting pyrotechnic events aboard the space shuttle. The testing device minimizes contact resistance degradation effects and so improves the reliability of resistance measurements taken with the device. Separate and independent voltage sensing and current supply circuits each include a pair of socket contacts for mating engagement with the pins of the initiator. The unknown resistance that is measured by the device is the resistance of the bridgewire of the initiator which is required to be between 0.95 and 1.15 ohms.

  3. Concept of Operations for the Next Generation Air Transportation System. Version 3.2

    DTIC Science & Technology

    2011-01-01

    Airside. Security Identification Display Area/Airport ( SIDA ) operations area, terminal perimeter, terminal airspace (security) • Landside. Terminal...Definition RTSS Remote Terminal Security Screening SAA Special Activity Airspace SIDA Security Identification Display Area SM Separation Management

  4. 21 CFR 868.2025 - Ultrasonic air embolism monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ultrasonic air embolism monitor. 868.2025 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2025 Ultrasonic air embolism monitor. (a) Identification. An ultrasonic air embolism monitor is a device used to detect air bubbles in...

  5. 21 CFR 868.2025 - Ultrasonic air embolism monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic air embolism monitor. 868.2025 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2025 Ultrasonic air embolism monitor. (a) Identification. An ultrasonic air embolism monitor is a device used to detect air bubbles in...

  6. 21 CFR 868.2025 - Ultrasonic air embolism monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic air embolism monitor. 868.2025 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2025 Ultrasonic air embolism monitor. (a) Identification. An ultrasonic air embolism monitor is a device used to detect air bubbles in...

  7. 40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...

  8. 40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...

  9. 40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY... annual air pollution control device inspection), you must complete the air pollution control device...

  10. AIRSLUG: A fortran program for the computation of type curves to estimate transmissivity and storativity from prematurely terminated air-pressurized slug tests

    USGS Publications Warehouse

    Greene, E.A.; Shapiro, A.M.

    1998-01-01

    The Fortran code AIRSLUG can be used to generate the type curves needed to analyze the recovery data from prematurely terminated air-pressurized slug tests. These type curves, when used with a graphical software package, enable the engineer or scientist to analyze field tests to estimate transmissivity and storativity. Prematurely terminating the slug test can significantly reduce the overall time needed to conduct the test, especially at low-permeability sites, thus saving time and money.The Fortran code AIRSLUG can be used to generate the type curves needed to analyze the recovery data from prematurely terminated air-pressurized slug tests. These type curves, when used with a graphical software package, enable the engineer or scientist to analyze field tests to estimate transmissivity and storativity. Prematurely terminating the slug test can significantly reduce the overall time needed to conduct the test, especially at low-permeability sites, thus saving time and money.

  11. Golf hand prosthesis performance of transradial amputees.

    PubMed

    Carey, Stephanie L; Wernke, Matthew M; Lura, Derek J; Kahle, Jason T; Dubey, Rajiv V; Highsmith, M Jason

    2015-06-01

    Typical upper limb prostheses may limit sports participation; therefore, specialized terminal devices are often needed. The purpose of this study was to evaluate the ability of transradial amputees to play golf using a specialized terminal device. Club head speed, X-factor, and elbow motion of two individuals with transradial amputations using an Eagle Golf terminal device were compared to a non-amputee during a golf swing. Measurements were collected pre/post training with various stances and grips. Both prosthesis users preferred a right-handed stance initially; however, after training, one preferred a left-handed stance. The amputees had slower club head speeds and a lower X-factor compared to the non-amputee golfer, but increased their individual elbow motion on the prosthetic side after training. Amputees enjoyed using the device, and it may provide kinematic benefits indicated by the increase in elbow flexion on the prosthetic side. The transradial amputees were able to swing a golf club with sufficient repetition, form, and velocity to play golf recreationally. Increased elbow flexion on the prosthetic side suggests a potential benefit from using the Eagle Golf terminal device. Participating in recreational sports can increase amputees' health and quality of life. © The International Society for Prosthetics and Orthotics 2014.

  12. Spin injection into silicon in three-terminal vertical and four-terminal lateral devices with Fe/Mg/MgO/Si tunnel junctions having an ultrathin Mg insertion layer

    NASA Astrophysics Data System (ADS)

    Sato, Shoichi; Nakane, Ryosho; Hada, Takato; Tanaka, Masaaki

    2017-12-01

    We demonstrate that the spin injection/extraction efficiency is enhanced by an ultrathin Mg insertion layer (⩽2 nm) in Fe /Mg /MgO /n+-Si tunnel junctions. In diode-type vertical three-terminal devices fabricated on a Si substrate, we observe the narrower three-terminal Hanle (N-3TH) signals indicating true spin injection into Si and estimate the spin polarization in Si to be 16% when the thickness of the Mg insertion layer is 1 nm, whereas no N-3TH signal is observed without the Mg insertion. This means that the spin injection/extraction efficiency is enhanced by suppressing the formation of a magnetically dead layer at the Fe/MgO interface. We also observe clear spin transport signals, such as nonlocal Hanle signals and spin-valve signals, in a lateral four-terminal device with the same Fe /Mg /MgO /n+-Si tunnel junctions fabricated on a Si-on-insulator substrate. It is found that both the intensity and linewidth of the spin signals are affected by the geometrical effects (device geometry and size). We have derived analytical functions taking into account the device structures, including channel thickness and electrode size, and estimated important parameters: spin lifetime and spin polarization. Our analytical functions explain the experimental results very well. Our study shows the importance of suppressing a magnetically dead layer and provides a unified understanding of spin injection/detection signals in different device geometries.

  13. 6. CABLE RACK, MEZZANINE LEVEL, INTERIOR OF TEST STAND 1A. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. CABLE RACK, MEZZANINE LEVEL, INTERIOR OF TEST STAND 1A. Looking south from north wall of terminal room. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  14. Terminal area air traffic control simulation

    NASA Technical Reports Server (NTRS)

    1977-01-01

    To study the impact of advanced aeronautical technologies on operations to and from terminal airports, a computer model of air traffic movements was developed. The advantages of fast-time simulation are discussed, and the arrival scheduling and flight simulation are described. A New York area study, user's guide, and programmer's guide are included.

  15. 40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device inspection), you must complete the air pollution control...

  16. 40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device inspection), you must complete the air pollution control...

  17. Effect of post annealing on spin accumulation and transport signals in Co{sub 2}FeSi/MgO/n{sup +}-Si on insulator devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tiwari, Ajay, E-mail: ajay1.tiwari@toshiba.co.jp; Inokuchi, Tomoaki; Ishikawa, Mizue

    The post annealing temperature dependence of spin accumulation and transport signals in Co{sub 2}FeSi/MgO/n{sup +}-Si on insulator were investigated. The spin signals were detected using 3- and 4-terminal Hanle, 2-terminal local and 4-terminal nonlocal magnetoresistance measurements. The post annealing temperature (T{sub A}) dependence of the magnitude in 3-terminal narrow Hanle signals is nearly constant up to T{sub A} < 400°C, however a slight decrease above T{sub A} ≥ 400°C is observed. This behavior is consistent with the T{sub A} dependence of the magnitude of 4-terminal nonlocal magnetoresistance (MR) signals. The spin polarization estimated from the 3-terminal narrow Hanle signals andmore » the magnitude of 2-terminal local MR signals show a slight improvement with increasing post annealing temperature with a peak at around 325°C and then start reducing slowly. The slight increase in the spin signal would be due to high spin polarization of Co{sub 2}FeSi as a result of structural ordering. The 2-terminal local MR signals do not vary significantly by annealing between as-deposited and T{sub A} = 400°C, indicating the robustness of our device. This result would be useful for future Si spintronics devices.« less

  18. 33 CFR 159.79 - Terminals.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Terminals. 159.79 Section 159.79 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.79 Terminals. Terminals must be solderless lugs...

  19. Terminal illness and access to Phase 1 experimental agents, surgeries and devices: reviewing the ethical arguments.

    PubMed

    Schüklenk, Udo; Lowry, Christopher

    2009-01-01

    The advent of AIDS brought about a group of patients unwilling to accept crucial aspects of the methodological standards for clinical research investigating Phase 1 drugs, surgeries or devices. Their arguments against placebo controls in trials, which depended--at the time--on the terminal status of patient volunteers led to a renewed discussion of the ethics of denying patients with catastrophic illnesses access to last-chance experimental drugs, surgeries or devices. Existing ethics and health policy literature on the topic of access to experimental drugs. The positions of those arguing for or against free access to experimental drugs for terminally ill patients are irreconcilable. At stake are questions about the kinds of personal sacrifices society can reasonably expect patients in clinical trials to make to ensure statistically predictive results. These would benefit by necessity a much larger number of current and future patients--the conflict is about individual versus public interests. It is also about the question of whether or not the state can legitimately prevent patients with terminal illnesses from unfettered access to experimental drugs, surgeries or devices in order to motivate them to participate in clinical trials. We review the ethical arguments for and against the provision of access to Phase 1 agents for terminally ill patients. Finding a compromise between providing free or no access to Phase 1 drugs for terminally ill patients. We ought to investigate means to increase access to experimental drugs for terminally ill patients without sacrificing necessary clinical trials' sounds scientific methods.

  20. Non-synchronous control of self-oscillating resonant converters

    DOEpatents

    Glaser, John Stanley; Zane, Regan Andrew

    2002-01-01

    A self-oscillating switching power converter has a controllable reactance including an active device connected to a reactive element, wherein the effective reactance of the reactance and the active device is controlled such that the control waveform for the active device is binary digital and is not synchronized with the switching converter output frequency. The active device is turned completely on and off at a frequency that is substantially greater than the maximum frequency imposed on the output terminals of the active device. The effect is to vary the average resistance across the active device output terminals, and thus the effective output reactance, thereby providing converter output control, while maintaining the response speed of the converter.

  1. Thermal-Mechanical Noise Based CMUT Characterization and Sensing

    PubMed Central

    Gurun, Gokce; Hochman, Michael; Hasler, Paul; Degertekin, F. Levent

    2012-01-01

    When capacitive micromachined ultrasonic transducers (CMUTs) are monolithically integrated with custom-designed low-noise electronics, the output noise of the system can be dominated by the CMUT thermal-mechanical noise both in air and in immersion even for devices with low capacitance. Since the thermal-mechanical noise can be related to the electrical admittance of the CMUTs, this provides an effective means of device characterization. This approach yields a novel method to test the functionality and uniformity of CMUT arrays and the integrated electronics where a direct connection to CMUT array element terminals is not available. These measurements can be performed in air at the wafer level, suitable for batch manufacturing and testing. We demonstrate this method on the elements of an 800-μm diameter CMUT-on-CMOS array designed for intravascular imaging in the 10-20 MHz range. Noise measurements in air show the expected resonance behavior and spring softening effects. Noise measurements in immersion for the same array provide useful information on both the acoustic cross talk and radiation properties of the CMUT array elements. The good agreement between a CMUT model based on finite difference and boundary element method and the noise measurements validates the model and indicates that the output noise is indeed dominated by thermal-mechanical noise. The measurement method can be exploited to implement CMUT based passive sensors to measure immersion medium properties, or other parameters affecting the electro-mechanics of the CMUT structure. PMID:22718877

  2. Thermal-mechanical-noise-based CMUT characterization and sensing.

    PubMed

    Gurun, Gokce; Hochman, Michael; Hasler, Paul; Degertekin, F Levent

    2012-06-01

    When capacitive micromachined ultrasonic transducers (CMUTs) are monolithically integrated with custom-designed low-noise electronics, the output noise of the system can be dominated by the CMUT thermal-mechanical noise both in air and in immersion even for devices with low capacitance. Because the thermal-mechanical noise can be related to the electrical admittance of the CMUTs, this provides an effective means of device characterization. This approach yields a novel method to test the functionality and uniformity of CMUT arrays and the integrated electronics when a direct connection to CMUT array element terminals is not available. Because these measurements can be performed in air at the wafer level, the approach is suitable for batch manufacturing and testing. We demonstrate this method on the elements of an 800-μm-diameter CMUT-on-CMOS array designed for intravascular imaging in the 10 to 20 MHz range. Noise measurements in air show the expected resonance behavior and spring softening effects. Noise measurements in immersion for the same array provide useful information on both the acoustic cross talk and radiation properties of the CMUT array elements. The good agreement between a CMUT model based on finite difference and boundary element methods and the noise measurements validates the model and indicates that the output noise is indeed dominated by thermal-mechanical noise. The measurement method can be exploited to implement CMUT-based passive sensors to measure immersion medium properties, or other parameters affecting the electro-mechanics of the CMUT structure.

  3. Occupational exposure to electromagnetic fields in the Polish Armed Forces.

    PubMed

    Sobiech, Jaromir; Kieliszek, Jarosław; Puta, Robert; Bartczak, Dagmara; Stankiewicz, Wanda

    2017-06-19

    Standard devices used by military personnel that may pose electromagnetic hazard include: radars, missile systems, radio navigation systems and radio transceivers. The aim of this study has been to evaluate the exposure of military personnel to electromagnetic fields. Occupational exposure to electromagnetic fields was analyzed in the work environment of personnel of 204 devices divided into 5 groups (surface-to-air missile system radars, aircraft and helicopters, communication devices, surveillance and height finder radars, airport radars and radio navigation systems). Measurements were carried out at indicators, device terminals, radio panels, above vehicle seats, in vehicle hatches, by cabinets containing high power vacuum tubes and other transmitter components, by transmission lines, connectors, etc. Portable radios emit the electric field strength between 20-80 V/m close to a human head. The manpack radio operator's exposure is 60-120 V/m. Inside vehicles with high frequency/very high frequency (HF/VHF) band radios, the electric field strength is between 7-30 V/m and inside the radar cabin it ranges between 9-20 V/m. Most of the personnel on ships are not exposed to the electromagnetic field from their own radar systems but rather by accidental exposure from the radar systems of other ships. Operators of surface-to-air missile systems are exposed to the electric field strength between 7-15 V/m and the personnel of non-directional radio beacons - 100-150 V/m. In 57% of military devices Polish soldiers work in the occupational protection zones. In 35% of cases, soldiers work in intermediate and hazardous zones and in 22% - only in the intermediate zone. In 43% of devices, military personnel are not exposed to electromagnetic field. Int J Occup Med Environ Health 2017;30(4):565-577. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  4. An exploratory study to determine the integrated technological air transportation system ground requirements of liquid-hydrogen-fueled subsonic, long-haul civil air transports

    NASA Technical Reports Server (NTRS)

    1976-01-01

    A baseline air terminal concept was developed which permitted airlines and the airport to operate JP- or LH2-fueled aircraft at common terminal gates. The concept included installation of a hydrogen liquefaction and storage facility on airport property, as well as the fuel distribution system. The capital investment and hydrogen-related operating costs to the airlines were estimated.

  5. Structures and electronic states of halogen-terminated graphene nano-flakes

    NASA Astrophysics Data System (ADS)

    Tachikawa, Hiroto; Iyama, Tetsuji

    2015-12-01

    Halogen-functionalized graphenes are utilized as electronic devices and energy materials. In the present paper, the effects of halogen-termination of graphene edge on the structures and electronic states of graphene flakes have been investigated by means of density functional theory (DFT) method. It was found that the ionization potential (Ip) and electron affinity of graphene (EA) are blue-shifted by the halogen termination, while the excitation energy is red-shifted. The drastic change showed a possibility as electronic devices such as field-effect transistors. The change of electronic states caused by the halogen termination of graphene edge was discussed on the basis of the theoretical results.

  6. 40 CFR 60.5195 - By what date must I conduct the initial air pollution control device inspection and make any...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection and make any necessary repairs? 60.5195 Section 60.5195... air pollution control device inspection and make any necessary repairs? (a) You must conduct an air... approved state plan, Federal plan, or delegation, as applicable. For air pollution control devices...

  7. 40 CFR 60.5195 - By what date must I conduct the initial air pollution control device inspection and make any...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection and make any necessary repairs? 60.5195 Section 60.5195... air pollution control device inspection and make any necessary repairs? (a) You must conduct an air... approved state plan, Federal plan, or delegation, as applicable. For air pollution control devices...

  8. 40 CFR 60.5195 - By what date must I conduct the initial air pollution control device inspection and make any...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection and make any necessary repairs? 60.5195 Section 60.5195... air pollution control device inspection and make any necessary repairs? (a) You must conduct an air... approved state plan, Federal plan, or delegation, as applicable. For air pollution control devices...

  9. Multi-Rate Secure Processor Terminal Architecture Study. Volume 1. Terminal Architecture.

    DTIC Science & Technology

    1981-06-01

    together because of the intimate relationship that must be established between the KG devices and the control of those devices to satisy security...9.6 kilobit for ti’.:., pass filter funtion because it’s time span is larger. The resultdot loading is estimated at 260 microseconds out of 833

  10. Operation mode switchable charge-trap memory based on few-layer MoS2

    NASA Astrophysics Data System (ADS)

    Hou, Xiang; Yan, Xiao; Liu, Chunsen; Ding, Shijin; Zhang, David Wei; Zhou, Peng

    2018-03-01

    Ultrathin layered two-dimensional (2D) semiconductors like MoS2 and WSe2 have received a lot of attention because of their excellent electrical properties and potential applications in electronic devices. We demonstrate a charge-trap memory with two different tunable operation modes based on a few-layer MoS2 channel and an Al2O3/HfO2/Al2O3 charge storage stack. Our device shows excellent memory properties under the traditional three-terminal operation mode. More importantly, unlike conventional charge-trap devices, this device can also realize the memory performance with just two terminals (drain and source) because of the unique atomic crystal electrical characteristics. Under the two-terminal operation mode, the erase/program current ratio can reach up to 104 with a stable retention property. Our study indicates that the conventional charge-trap memory cell can also realize the memory performance without the gate terminal based on novel two dimensional materials, which is meaningful for low power consumption and high integration density applications.

  11. 14 CFR 93.177 - Operations in the Special Air Traffic Rule Area.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Area. 93.177 Section 93.177 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... in the Vicinity of Luke AFB, AZ § 93.177 Operations in the Special Air Traffic Rule Area. (a) Unless... Luke Terminal Area designated in § 93.176 unless— (1) Before operating within the Luke Terminal area...

  12. 9 CFR 3.117 - Terminal facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... must not commingle marine mammal shipments with inanimate cargo. All animal holding areas of a terminal... containing marine mammals when the air temperature within such animal holding area is 23.9 °C (75 °F) or higher. The air temperature around any marine mammal in any animal holding area must not be allowed to...

  13. 9 CFR 3.117 - Terminal facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... must not commingle marine mammal shipments with inanimate cargo. All animal holding areas of a terminal... containing marine mammals when the air temperature within such animal holding area is 23.9 °C (75 °F) or higher. The air temperature around any marine mammal in any animal holding area must not be allowed to...

  14. 9 CFR 3.117 - Terminal facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... must not commingle marine mammal shipments with inanimate cargo. All animal holding areas of a terminal... containing marine mammals when the air temperature within such animal holding area is 23.9 °C (75 °F) or higher. The air temperature around any marine mammal in any animal holding area must not be allowed to...

  15. 9 CFR 3.117 - Terminal facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... must not commingle marine mammal shipments with inanimate cargo. All animal holding areas of a terminal... containing marine mammals when the air temperature within such animal holding area is 23.9 °C (75 °F) or higher. The air temperature around any marine mammal in any animal holding area must not be allowed to...

  16. 9 CFR 3.117 - Terminal facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... must not commingle marine mammal shipments with inanimate cargo. All animal holding areas of a terminal... containing marine mammals when the air temperature within such animal holding area is 23.9 °C (75 °F) or higher. The air temperature around any marine mammal in any animal holding area must not be allowed to...

  17. 40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...

  18. 40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...

  19. 40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... pollution control device inspection? (a) The initial air pollution control device inspection must be... meeting the amended emission limitations. (b) Within 10 operating days following an air pollution control...

  20. Solid state safety jumper cables

    DOEpatents

    Kronberg, James W.

    1993-01-01

    Solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating "positive" terminals, and one has a lower voltage than the reference voltage, indicating "negative" terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

  1. Solid state safety jumper cables

    DOEpatents

    Kronberg, J.W.

    1993-02-23

    Solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating positive'' terminals, and one has a lower voltage than the reference voltage, indicating negative'' terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

  2. CMOS compatible thin-film ALD tungsten nanoelectromechanical devices

    NASA Astrophysics Data System (ADS)

    Davidson, Bradley Darren

    This research focuses on the development of a novel, low-temperature, CMOS compatible, atomic-layer-deposition (ALD) enabled NEMS fabrication process for the development of ALD Tungsten (WALD) NEMS devices. The devices are intended for use in CMOS/NEMS hybrid systems, and NEMS based micro-processors/controllers capable of reliable operation in harsh environments not accessible to standard CMOS technologies. The majority of NEMS switches/devices to date have been based on carbon-nano-tube (CNT) designs. The devices consume little power during actuation, and as expected, have demonstrated actuation voltages much smaller than MEMS switches. Unfortunately, NEMS CNT switches are not typically CMOS integrable due to the high temperatures required for their growth, and their fabrication typically results in extremely low and unpredictable yields. Thin-film NEMS devices offer great advantages over reported CNT devices for several reasons, including: higher fabrication yields, low-temperature (CMOS compatible) deposition techniques like ALD, and increased control over design parameters/device performance metrics, i.e., device geometry. Furthermore, top-down, thin-film, nano-fabrication techniques are better capable of producing complicated device geometries than CNT based processes, enabling the design and development of multi-terminal switches well-suited for low-power hybrid NEMS/CMOS systems as well as electromechanical transistors and logic devices for use in temperature/radiation hard computing architectures. In this work several novel, low-temperature, CMOS compatible fabrication technologies, employing WALD as a structural layer for MEMS or NEMS devices, were developed. The technologies developed are top-down nano-scale fabrication processes based on traditional micro-machining techniques commonly used in the fabrication of MEMS devices. Using these processes a variety of novel WALD NEMS devices have been successfully fabricated and characterized. Using two different WALD fabrication technologies two generations of 2-terminal WALD NEMS switches have been developed. These devices have functional gap heights of 30-50 nm, and actuation voltages typically ranging from 3--5 Volts. Via the extension of a two terminal WALD technology novel 3-terminal WALD NEMS devices were developed. These devices have actuation voltages ranging from 1.5--3 Volts, reliabilities in excess of 2 million cycles, and have been designed to be the fundamental building blocks for WALD NEMS complementary inverters. Through the development of these devices several advancements in the modeling and design of thin-film NEMS devices were achieved. A new model was developed to better characterize pre-actuation currents commonly measured for NEMS switches with nano-scale gate-to-source gap heights. The developed model is an extension of the standard field-emission model and considers the electromechanical response, and electric field effects specific to thin-film NEMS switches. Finally, a multi-physics FEM/FD based model was developed to simulate the dynamic behavior of 2 or 3-terminal electrostatically actuated devices whose electrostatic domains have an aspect ratio on the order of 10-3. The model uses a faux-Lagrangian finite difference method to solve Laplaces equation in a quasi-statatically deforming domain. This model allows for the numerical characterization and design of thin-film NEMS devices not feasible using typical non-specialized BEM/FEM based software. Using this model several novel and feasible designs for fixed-fixed 3-terminal WALD NEMS switches capable for the construction of complementary inverters were discovered.

  3. Normally-off AlGaN/GaN-based MOS-HEMT with self-terminating TMAH wet recess etching

    NASA Astrophysics Data System (ADS)

    Son, Dong-Hyeok; Jo, Young-Woo; Won, Chul-Ho; Lee, Jun-Hyeok; Seo, Jae Hwa; Lee, Sang-Heung; Lim, Jong-Won; Kim, Ji Heon; Kang, In Man; Cristoloveanu, Sorin; Lee, Jung-Hee

    2018-03-01

    Normally-off AlGaN/GaN-based MOS-HEMT has been fabricated by utilizing damage-free self-terminating tetramethyl ammonium hydroxide (TMAH) recess etching. The device exhibited a threshold voltage of +2.0 V with good uniformity, extremely small hysteresis of ∼20 mV, and maximum drain current of 210 mA/mm. The device also exhibited excellent off-state performances, such as breakdown voltage of ∼800 V with off-state leakage current as low as ∼10-12 A and high on/off current ratio (Ion/Ioff) of 1010. These excellent device performances are believed to be due to the high quality recessed surface, provided by the simple self-terminating TMAH etching.

  4. Resonant optical device with a microheater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lentine, Anthony L.; DeRose, Christopher

    2017-04-04

    A resonant photonic device is provided. The device comprises an optical waveguiding element, such as an optical resonator, that includes a diode junction region, two signal terminals configured to apply a bias voltage across the junction region, and a heater laterally separated from the optical waveguiding element. A semiconductor electrical barrier element is juxtaposed to the heater. A metallic strip is electrically and thermally connected at one end to a signal terminal of the optical waveguiding element and thermally connected at another end to the barrier element.

  5. Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis.

    PubMed

    Ahn, Eun Jin; Choi, Geun Joo; Kang, Hyun; Baek, Chong Wha; Jung, Yong Hun; Woo, Young Cheol; Bang, Si Ra

    2016-01-01

    Air-Q® (air-Q) is a supraglottic airway device which can be used as a guidance of intubation in pediatric as well as in adult patients. We evaluated the efficacy and safety of air-Q compared to other airway devices during general anesthesia in pediatric patients by conducting a systematic review and meta-analysis. A total of 10 studies including 789 patients were included in the final analysis. Compared with other supraglottic airway devices, air-Q showed no evidence for a difference in leakage pressure and insertion time. The ease of insertion was significantly lower than other supraglottic airway devices. The success rate of intubation was significantly lower than other airway devices. However, fiberoptic view was better through the air-Q than other supraglottic airway devices. Therefore, air-Q could be a safe substitute for other airway devices and may provide better fiberoptic bronchoscopic view.

  6. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  7. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  8. 40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... Compliance Requirements § 60.2141 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after...

  9. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  10. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  11. 40 CFR 424.10 - Applicability; description of the open electric furnaces with wet air pollution control devices...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... electric furnaces with wet air pollution control devices subcategory. 424.10 Section 424.10 Protection of... MANUFACTURING POINT SOURCE CATEGORY Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory § 424.10 Applicability; description of the open electric furnaces with wet air pollution control devices...

  12. 40 CFR 60.2141 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection? 60.2141 Section 60.2141 Protection of Environment... Compliance Requirements § 60.2141 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after...

  13. Infrastructure-Less Communication Platform for Off-The-Shelf Android Smartphones

    PubMed Central

    2018-01-01

    As smartphones and other small portable devices become more sophisticated and popular, opportunities for communication and information sharing among such device users have increased. In particular, since it is known that infrastructure-less device-to-device (D2D) communication platforms consisting only of such devices are excellent in terms of, for example, bandwidth efficiency, efforts are being made to merge their information sharing capabilities with conventional infrastructure. However, efficient multi-hop communication is difficult with the D2D communication protocol, and many conventional D2D communication platforms require modifications of the protocol and terminal operating systems (OSs). In response to these issues, this paper reports on a proposed tree-structured D2D communication platform for Android devices that combines Wi-Fi Direct and Wi-Fi functions. The proposed platform, which is expected to be used with general Android 4.0 (or higher) OS equipped terminals, makes it possible to construct an ad hoc network instantaneously without sharing prior knowledge among participating devices. We will show the feasibility of our proposed platform through its design and demonstrate the implementation of a prototype using real devices. In addition, we will report on our investigation into communication delays and stability based on the number of hops and on terminal performance through experimental confirmation experiments. PMID:29510536

  14. Infrastructure-Less Communication Platform for Off-The-Shelf Android Smartphones.

    PubMed

    Oide, Takuma; Abe, Toru; Suganuma, Takuo

    2018-03-04

    As smartphones and other small portable devices become more sophisticated and popular, opportunities for communication and information sharing among such device users have increased. In particular, since it is known that infrastructure-less device-to-device (D2D) communication platforms consisting only of such devices are excellent in terms of, for example, bandwidth efficiency, efforts are being made to merge their information sharing capabilities with conventional infrastructure. However, efficient multi-hop communication is difficult with the D2D communication protocol, and many conventional D2D communication platforms require modifications of the protocol and terminal operating systems (OSs). In response to these issues, this paper reports on a proposed tree-structured D2D communication platform for Android devices that combines Wi-Fi Direct and Wi-Fi functions. The proposed platform, which is expected to be used with general Android 4.0 (or higher) OS equipped terminals, makes it possible to construct an ad hoc network instantaneously without sharing prior knowledge among participating devices. We will show the feasibility of our proposed platform through its design and demonstrate the implementation of a prototype using real devices. In addition, we will report on our investigation into communication delays and stability based on the number of hops and on terminal performance through experimental confirmation experiments.

  15. 48 CFR 52.247-52 - Clearance and Documentation Requirements-Shipments to DOD Air or Water Terminal Transshipment...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 2 2013-10-01 2013-10-01 false Clearance and Documentation Requirements-Shipments to DOD Air or Water Terminal Transshipment Points. 52.247-52 Section 52.247-52 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES...

  16. 77 FR 5055 - Certain Liquid Crystal Display Devices and Products Containing the Same; Determination Not To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... presiding administrative law judge (``ALJ'') granting a joint motion to terminate the investigation based on... Motion To Terminate Based on Settlement Agreement; Termination of the Investigation AGENCY: U.S... parties filed a joint motion to terminate the investigation based on a settlement agreement. On July 21...

  17. High-speed optical links for UAV applications

    NASA Astrophysics Data System (ADS)

    Chen, C.; Grier, A.; Malfa, M.; Booen, E.; Harding, H.; Xia, C.; Hunwardsen, M.; Demers, J.; Kudinov, K.; Mak, G.; Smith, B.; Sahasrabudhe, A.; Patawaran, F.; Wang, T.; Wang, A.; Zhao, C.; Leang, D.; Gin, J.; Lewis, M.; Nguyen, D.; Quirk, K.

    2017-02-01

    High speed optical backbone links between a fleet of UAVs is an integral part of the Facebook connectivity architecture. To support the architecture, the optical terminals need to provide high throughput rates (in excess of tens of Gbps) while achieving low weight and power consumption. The initial effort is to develop and demonstrate an optical terminal capable of meeting the data rate requirements and demonstrate its functions for both air-air and air-ground engagements. This paper is a summary of the effort to date.

  18. Concept of Operations for Interval Management Arrivals and Approach

    NASA Technical Reports Server (NTRS)

    Hicok, Daniel S.; Barmore, Bryan E.

    2016-01-01

    This paper presents the concept of operations for interval management operations to be deployed in the US National Airspace System (NAS) by the Federal Aviation Administration (FAA) after 2020. The use of interval management operations is described that begin in en route airspace and continue to a termination point inside the arrival terminal area, in a terminal environment that includes other arrival management tools such as arrival metering, Ground-based Interval Management - Spacing (GIM-S), and Terminal Sequencing and Spacing (TSAS). The roles of Air Traffic Controllers and Flight Crews and the ground automation tools that are used by Air Traffic Controllers to enable the primary operation and variations are described.

  19. 21 CFR 868.6250 - Portable air compressor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...

  20. 21 CFR 880.5045 - Medical recirculating air cleaner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical recirculating air cleaner. 880.5045... Therapeutic Devices § 880.5045 Medical recirculating air cleaner. (a) Identification. A medical recirculating air cleaner is a device used to remove particles from the air for medical purposes. The device may...

  1. 21 CFR 868.6250 - Portable air compressor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...

  2. 21 CFR 868.6250 - Portable air compressor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable air compressor. 868.6250 Section 868.6250...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6250 Portable air compressor. (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e...

  3. 21 CFR 880.5045 - Medical recirculating air cleaner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical recirculating air cleaner. 880.5045... Therapeutic Devices § 880.5045 Medical recirculating air cleaner. (a) Identification. A medical recirculating air cleaner is a device used to remove particles from the air for medical purposes. The device may...

  4. 21 CFR 880.5045 - Medical recirculating air cleaner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical recirculating air cleaner. 880.5045... Therapeutic Devices § 880.5045 Medical recirculating air cleaner. (a) Identification. A medical recirculating air cleaner is a device used to remove particles from the air for medical purposes. The device may...

  5. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 1 Device categories Characteristics adversely affected Fuel-Air System Carburetors and fuel injection systems All. Air-fuel ratio modifiers (e.g., air bleeds) All. Atomization devices (acoustic and mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  6. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 1 Device categories Characteristics adversely affected Fuel-Air System Carburetors and fuel injection systems All. Air-fuel ratio modifiers (e.g., air bleeds) All. Atomization devices (acoustic and mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  7. Prosthetic Jamming Terminal Device: A Case Study of Untethered Soft Robotics

    PubMed Central

    Amend, John; Farrell, Todd; Latour, Debra; Martinez, Carlos; Johansson, Jen; McNicoll, Anthony; Wartenberg, Marek; Naseef, Samuel; Hanson, William; Culley, William

    2016-01-01

    Abstract This article illuminates the major and often overlooked challenge of untethering soft robotic systems through the context of recent work, in which soft robotic gripper technology enabled by jamming of granular media was applied to a prosthetic jamming terminal device (PJTD). The PJTD's technical and market feasibility was evaluated in a pilot study with two upper-limb amputees. A PJTD prototype was tested against a commercial device (Motion Control electric terminal service with a one degree-of-freedom pinching mechanism) using two existing hand function tests: the first quantified the device's speed in picking and placing small blocks and the second evaluated a person's ability to perform activities of daily living (ADLs). The PJTD prototype performed slightly slower than its commercial counterpart in the first test. While both participants successfully completed all the ADLs with both devices in the second test, the commercial device scored marginally higher. Results suggested that PJTD can have potential benefits over existing terminal devices, such as providing the capability to firmly grasp tools due to the ability of PJTD to conform to arbitrary surfaces and reducing compensatory shoulder movements due to its axisymmetric design. Some downsides were that users reported fatigue while operating the PJTD, as most operations require pushing the PJTD against target objects to adequately conform to them. The greatest drawback for the PJTD is also a major roadblock preventing a number of soft robotic research projects from making an impact in real-world applications: pneumatic technology required for operating the PJTD is currently too large and heavy to enable compact untethered operation. PMID:28078196

  8. 40 CFR 60.2716 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection? 60.2716 Section 60.2716 Protection of Environment... Requirements § 60.2716 By what date must I conduct the annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control device...

  9. 40 CFR 60.2706 - By what date must I conduct the initial air pollution control device inspection?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection? 60.2706 Section 60.2706 Protection of Environment... Requirements § 60.2706 By what date must I conduct the initial air pollution control device inspection? (a) The initial air pollution control device inspection must be conducted within 60 days after installation of the...

  10. 40 CFR 62.14441 - When must I inspect my HMIWI equipment and air pollution control devices?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and air pollution control devices? 62.14441 Section 62.14441 Protection of Environment ENVIRONMENTAL... my HMIWI equipment and air pollution control devices? (a) You must inspect your large, medium, small... inspect the air pollution control devices on your large, medium, small or small rural HMIWI by May 13...

  11. 40 CFR 62.14441 - When must I inspect my HMIWI equipment and air pollution control devices?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and air pollution control devices? 62.14441 Section 62.14441 Protection of Environment ENVIRONMENTAL... my HMIWI equipment and air pollution control devices? (a) You must inspect your large, medium, small... inspect the air pollution control devices on your large, medium, small or small rural HMIWI by May 13...

  12. Energy storage cell impedance measuring apparatus, methods and related systems

    DOEpatents

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.

    2017-12-26

    Energy storage cell impedance testing devices, circuits, and related methods are disclosed. An energy storage cell impedance measuring device includes a sum of sinusoids (SOS) current excitation circuit including differential current sources configured to isolate a ground terminal of the differential current sources from a positive terminal and a negative terminal of an energy storage cell. A method includes applying an SOS signal comprising a sum of sinusoidal current signals to the energy storage cell with the SOS current excitation circuit, each of the sinusoidal current signals oscillating at a different one of a plurality of different frequencies. The method also includes measuring an electrical signal at a positive terminal and a negative terminal of the energy storage cell, and computing an impedance of the energy storage cell at each of the plurality of different frequencies using the measured electrical signal.

  13. Measurements of high impedance two-terminal device with SMU NI PXIe-4139

    NASA Astrophysics Data System (ADS)

    Bogdanov, S. V.; Lelekov, E. T.; Kovalev, I. V.; Zelenkov, P. V.; Lelekov, A. T.

    2016-11-01

    To measure high-frequency and low-frequency impedance of betavoltaic power sources (it can be represented as two-terminal device), measurement stand was created. To measure high-frequency part need to inject external test signal through the current transformer with waveform generator and need to use external high-frequency current sensor, because of SMU PXIe-4139 current channel limitations.

  14. One dimensional metallic edges in atomically thin WSe2 induced by air exposure

    NASA Astrophysics Data System (ADS)

    Addou, Rafik; Smyth, Christopher M.; Noh, Ji-Young; Lin, Yu-Chuan; Pan, Yi; Eichfeld, Sarah M.; Fölsch, Stefan; Robinson, Joshua A.; Cho, Kyeongjae; Feenstra, Randall M.; Wallace, Robert M.

    2018-04-01

    Transition metal dichalcogenides are a unique class of layered two-dimensional (2D) crystals with extensive promising applications. Tuning the electronic properties of low-dimensional materials is vital for engineering new functionalities. Surface oxidation is of particular interest because it is a relatively simple method of functionalization. By means of scanning probe microscopy and x-ray photoelectron spectroscopy, we report the observation of metallic edges in atomically thin WSe2 monolayers grown by chemical vapor deposition on epitaxial graphene. Scanning tunneling microscopy shows structural details of WSe2 edges and scanning tunneling spectroscopy reveals the metallic nature of the oxidized edges. Photoemission demonstrates that the formation of metallic sub-stoichiometric tungsten oxide (WO2.7) is responsible for the high conductivity measured along the edges. Ab initio calculations validate the susceptibility of WSe2 nanoribbon edges to oxidation. The zigzag terminated edge exhibits metallic behavior prior the air-exposure and remains metallic after oxidation. Comprehending and exploiting this property opens a new opportunity for application in advanced electronic devices.

  15. 40 CFR 60.5195 - By what date must I conduct the initial air pollution control device inspection and make any...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection and make any necessary repairs? 60.5195 Section 60.5195... air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device inspection according to § 60.5220(c) by the final compliance date under the...

  16. 40 CFR 60.4875 - By what date must I conduct the initial air pollution control device inspection and make any...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air pollution control device inspection and make any necessary repairs? 60.4875 Section 60.4875... Initial Compliance Requirements § 60.4875 By what date must I conduct the initial air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device...

  17. 40 CFR 60.4875 - By what date must I conduct the initial air pollution control device inspection and make any...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection and make any necessary repairs? 60.4875 Section 60.4875... Initial Compliance Requirements § 60.4875 By what date must I conduct the initial air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device...

  18. 40 CFR 60.4875 - By what date must I conduct the initial air pollution control device inspection and make any...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection and make any necessary repairs? 60.4875 Section 60.4875... Initial Compliance Requirements § 60.4875 By what date must I conduct the initial air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device...

  19. 40 CFR 60.5215 - By what date must I conduct annual air pollution control device inspections and make any...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution control device used to comply with the emission limits, according to § 60.5220(c), no later than 12 months following the previous annual air pollution control device...

  20. 40 CFR 60.4875 - By what date must I conduct the initial air pollution control device inspection and make any...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspection and make any necessary repairs? 60.4875 Section 60.4875... Initial Compliance Requirements § 60.4875 By what date must I conduct the initial air pollution control device inspection and make any necessary repairs? (a) You must conduct an air pollution control device...

  1. 40 CFR 60.5215 - By what date must I conduct annual air pollution control device inspections and make any...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution control device used to comply with the emission limits, according to § 60.5220(c), no later than 12 months following the previous annual air pollution control device...

  2. 40 CFR 60.5215 - By what date must I conduct annual air pollution control device inspections and make any...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution control device used to comply with the emission limits, according to § 60.5220(c), no later than 12 months following the previous annual air pollution control device...

  3. User Delay Cost Model and Facilities Maintenance Cost Model for a Terminal Control Area : Volume 2. User's Manual and Program Documentation for the User Delay Cost Model

    DOT National Transportation Integrated Search

    1978-05-01

    The User Delay Cost Model (UDCM) is a Monte Carlo simulation of certain classes of movement of air traffic in the Boston Terminal Control Area (TCA). It incorporates a weather module, an aircraft generation module, a facilities module, and an air con...

  4. Four-terminal connector for measuring resistance of a pyrotechnic initiator

    NASA Technical Reports Server (NTRS)

    Robinson, Robert L. (Inventor); Graves, Thomas J. (Inventor); Hoffman, III, William C. (Inventor)

    1989-01-01

    A four-terminal electrical connector device (40) for testing and measuring unknown resistances of initiators (11) used for starting pyrotechnic events aboard a Space Transportation System. The testing device minimizes contact resistance degradation effects and so improves the reliability of resistance measurement taken with the device. Separate and independent voltage sensing (19) and current supply (20) circuits each includes a pair of socket contacts (13-16) for mating engagement with the pins (17,18) of the initiator. The unknown resistance that is measured by the device is the resistance of the bridgewire (23) of the initiator which is required to be between 0.95 and 1.15 ohms.

  5. Logic circuit prototypes for three-terminal magnetic tunnel junctions with mobile domain walls

    PubMed Central

    Currivan-Incorvia, J. A.; Siddiqui, S.; Dutta, S.; Evarts, E. R.; Zhang, J.; Bono, D.; Ross, C. A.; Baldo, M. A.

    2016-01-01

    Spintronic computing promises superior energy efficiency and nonvolatility compared to conventional field-effect transistor logic. But, it has proven difficult to realize spintronic circuits with a versatile, scalable device design that is adaptable to emerging material physics. Here we present prototypes of a logic device that encode information in the position of a magnetic domain wall in a ferromagnetic wire. We show that a single three-terminal device can perform inverter and buffer operations. We demonstrate one device can drive two subsequent gates and logic propagation in a circuit of three inverters. This prototype demonstration shows that magnetic domain wall logic devices have the necessary characteristics for future computing, including nonlinearity, gain, cascadability, and room temperature operation. PMID:26754412

  6. In-Operando Spatial Imaging of Edge Termination Electric Fields in GaN Vertical p-n Junction Diodes

    DOE PAGES

    Leonard, Francois; Dickerson, J. R.; King, M. P.; ...

    2016-05-03

    Control of electric fields with edge terminations is critical to maximize the performance of high-power electronic devices. We proposed a variety of edge termination designs which makes the optimization of such designs challenging due to many parameters that impact their effectiveness. And while modeling has recently allowed new insight into the detailed workings of edge terminations, the experimental verification of the design effectiveness is usually done through indirect means, such as the impact on breakdown voltages. In this letter, we use scanning photocurrent microscopy to spatially map the electric fields in vertical GaN p-n junction diodes in operando. We alsomore » reveal the complex behavior of seemingly simple edge termination designs, and show how the device breakdown voltage correlates with the electric field behavior. Modeling suggests that an incomplete compensation of the p-type layer in the edge termination creates a bilayer structure that leads to these effects, with variations that significantly impact the breakdown voltage.« less

  7. Concept of Operations for Interval Management Arrivals and Approach

    NASA Technical Reports Server (NTRS)

    Hicok, Daniel S.; Barmore, Bryan E.

    2016-01-01

    This paper presents the concept of operations for interval management operations to be deployed in the US National Airspace System (NAS) by the Federal Aviation Administration (FAA) Interval Management Program. The arrivals and approach operations are explored in detail including the primary operation and variations. The use of interval management operations is described that begin in en route airspace and continue to a termination point inside the arrival terminal area in the highly automated terminal environment that includes other arrival management tools such as arrival metering, Ground-based Interval Management - Spacing (GIM-S), and Terminal Sequencing and Spacing (TSAS). The roles of Air Traffic and Pilots and the ground automation tools that are used by Air Traffic Controllers to enable the operations are explored.

  8. An Elementary Algorithm for Autonomous Air Terminal Merging and Interval Management

    NASA Technical Reports Server (NTRS)

    White, Allan L.

    2017-01-01

    A central element of air traffic management is the safe merging and spacing of aircraft during the terminal area flight phase. This paper derives and examines an algorithm for the merging and interval managing problem for Standard Terminal Arrival Routes. It describes a factor analysis for performance based on the distribution of arrivals, the operating period of the terminal, and the topology of the arrival routes; then presents results from a performance analysis and from a safety analysis for a realistic topology based on typical routes for a runway at Phoenix International Airport. The heart of the safety analysis is a statistical derivation on how to conduct a safety analysis for a local simulation when the safety requirement is given for the entire airspace.

  9. A Conceptual Design of a Departure Planner Decision Aid

    NASA Technical Reports Server (NTRS)

    Anagnostakis, Ioannis; Idris, Husni R.; Clark, John-Paul; Feron, Eric; Hansman, R. John; Odoni, Amedeo R.; Hall, William D.

    2000-01-01

    Terminal area Air Traffic Management handles both arriving and departing traffic. To date, research work on terminal area operations has focused primarily on the arrival flow and typically departures are taken into account only in an approximate manner. However, arrivals and departures are highly coupled processes especially in the terminal airspace, with complex interactions and sharing of the same airport resources between arrivals and departures taking place in practically every important terminal area. Therefore, the addition of automation aids for departures, possibly in co-operation with existing arrival flow automation systems, could have a profound contribution in enhancing the overall efficiency of airport operations. This paper presents the conceptual system architecture for such an automation aid, the Departure Planner (DP). This architecture can be used as a core in the development of decision-aiding systems to assist air traffic controllers in improving the performance of departure operations and optimize runway time allocation among different operations at major congested airports. The design of such systems is expected to increase the overall efficiency of terminal area operations and yield benefits for all stakeholders involved in Air Traffic Management (ATM) operations, users as well as service providers.

  10. Image transfer by cascaded stack of photonic crystal and air layers.

    PubMed

    Shen, C; Michielsen, K; De Raedt, H

    2006-01-23

    We demonstrate image transfer by a cascaded stack consisting of two and three triangular-lattice photonic crystal slabs separated by air. The quality of the image transfered by the stack is sensitive to the air/photonic crystal interface termination and the frequency. Depending on the frequency and the surface termination, the image can be transfered by the stack with very little deterioration of the resolution, that is the resolution of the final image is approximately the same as the resolution of the image formed behind one single photonic crystal slab.

  11. 40 CFR 79.24 - Termination of registration of additives.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... additives. 79.24 Section 79.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGISTRATION OF FUELS AND FUEL ADDITIVES Additive Registration Procedures § 79.24 Termination of registration of additives. Registration may be terminated by the Administrator if the additive...

  12. 40 CFR 79.24 - Termination of registration of additives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... additives. 79.24 Section 79.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGISTRATION OF FUELS AND FUEL ADDITIVES Additive Registration Procedures § 79.24 Termination of registration of additives. Registration may be terminated by the Administrator if the additive...

  13. 40 CFR 79.24 - Termination of registration of additives.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... additives. 79.24 Section 79.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGISTRATION OF FUELS AND FUEL ADDITIVES Additive Registration Procedures § 79.24 Termination of registration of additives. Registration may be terminated by the Administrator if the additive...

  14. 40 CFR 79.24 - Termination of registration of additives.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... additives. 79.24 Section 79.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGISTRATION OF FUELS AND FUEL ADDITIVES Additive Registration Procedures § 79.24 Termination of registration of additives. Registration may be terminated by the Administrator if the additive...

  15. 40 CFR 79.24 - Termination of registration of additives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... additives. 79.24 Section 79.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGISTRATION OF FUELS AND FUEL ADDITIVES Additive Registration Procedures § 79.24 Termination of registration of additives. Registration may be terminated by the Administrator if the additive...

  16. 14 CFR 211.35 - Termination of eligibility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PROCEEDINGS) ECONOMIC REGULATIONS APPLICATIONS FOR PERMITS TO FOREIGN AIR CARRIERS Freely Associated State Air... essential air transportation subsidy compensation), or subparagraph (c) (limited interstate air transportation authority), of paragraph (5) of the Agreement on Civil Aviation Economic Services and Related...

  17. Triangular lattice atomic layer of Sn(1 × 1) at graphene/SiC(0001) interface

    NASA Astrophysics Data System (ADS)

    Hayashi, Shingo; Visikovskiy, Anton; Kajiwara, Takashi; Iimori, Takushi; Shirasawa, Tetsuroh; Nakastuji, Kan; Miyamachi, Toshio; Nakashima, Shuhei; Yaji, Koichiro; Mase, Kazuhiko; Komori, Fumio; Tanaka, Satoru

    2018-01-01

    Sn atomic layers attract considerable interest owing to their spin-related physical properties caused by their strong spin-orbit interactions. We performed Sn intercalation into the graphene/SiC(0001) interface and found a new type of Sn atomic layer. Sn atoms occupy on-top sites of Si-terminated SiC(0001) with in-plane Sn-Sn bondings, resulting in a triangular lattice. Angle-resolved photoemission spectroscopy revealed characteristic dispersions at \\bar{\\text{K}} and \\bar{\\text{M}} points, which agreed well with density functional theory calculations. The Sn triangular lattice atomic layer at the interface showed no oxidation upon exposure to air, which is useful for characterization and device fabrication ex situ.

  18. A dual channel three-terminal np-LDMOS with both majorities for conduction

    NASA Astrophysics Data System (ADS)

    Kong, Moufu; Yi, Bo; Zhang, Bingke

    2018-02-01

    A novel dual channel three-terminal np-LDMOS power device with both electrons and holes for conduction is proposed in this paper. Based on a new approach of inducing a large-signal which is processed by a simple circuit for controlling the gate of p-LDMOS inside the device, the new np-LDMOS only requires one external gate controlling voltage signal that can be performed as an n-LDMOS device. The SOA of the new device is improved in comparison with the n-LDMOS device, since the counteracting of electric flux density produced by the both type of carriers' currents. Furthermore, the specific on-resistance of the np-LDMOS device is reduced by about 19% when comparing with that of the conventional one. The control method and performances of the proposed power device are investigated and authenticated by numerical simulations.

  19. Integrated neuron circuit for implementing neuromorphic system with synaptic device

    NASA Astrophysics Data System (ADS)

    Lee, Jeong-Jun; Park, Jungjin; Kwon, Min-Woo; Hwang, Sungmin; Kim, Hyungjin; Park, Byung-Gook

    2018-02-01

    In this paper, we propose and fabricate Integrate & Fire neuron circuit for implementing neuromorphic system. Overall operation of the circuit is verified by measuring discrete devices and the output characteristics of the circuit. Since the neuron circuit shows asymmetric output characteristic that can drive synaptic device with Spike-Timing-Dependent-Plasticity (STDP) characteristic, the autonomous weight update process is also verified by connecting the synaptic device and the neuron circuit. The timing difference of the pre-neuron and the post-neuron induce autonomous weight change of the synaptic device. Unlike 2-terminal devices, which is frequently used to implement neuromorphic system, proposed scheme of the system enables autonomous weight update and simple configuration by using 4-terminal synapse device and appropriate neuron circuit. Weight update process in the multi-layer neuron-synapse connection ensures implementation of the hardware-based artificial intelligence, based on Spiking-Neural- Network (SNN).

  20. Unplanned gait termination in individuals with multiple sclerosis.

    PubMed

    Roeing, Kathleen L; Moon, Yaejin; Sosnoff, Jacob J

    2017-03-01

    Despite the pervasive nature of gait impairment in multiple sclerosis (MS), there is limited information concerning the control of gait termination in individuals with MS. The purpose of this investigation was to examine unplanned gait termination with and without cognitive distractors in individuals with MS compared to healthy controls. Thirty-one individuals with MS and 14 healthy controls completed a series of unplanned gait termination tasks over a pressure sensitive walkway under distracting and non-distracting conditions. Individuals with MS were further broken down into groups based on assistive device use: (no assistive device (MS noAD ) n=18; and assistive device (MS AD ) n=13). Individuals with MS who walked with an assistive device (MS AD : 67.8±15.1cm/s) walked slower than individuals without an assistive device (MS noAD : 110.4±32.3cm/s, p<0.01) and controls (120.0±30.0cm/s; p<0.01). There was a significant reduction in velocity in the cognitively distracting condition (93.4±32.1cm/s) compared to the normal condition [108.8±36.2cm/s; F(1,43)=3.4, p=0.04]. All participants took longer to stop during the distracting condition (1.7±0.6s) than the non-distracting condition (1.4±0.4s; U=673.0 p<0.01). After controlling for gait velocity, post-hoc analysis revealed the MS AD group took significantly longer to stop compared to the control group (p=0.05). Further research investigating the control of unplanned gait termination in MS is warranted. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A simple, efficient resistance soldering apparatus

    NASA Technical Reports Server (NTRS)

    Vermillion, C. M.

    1972-01-01

    Multiple resistance soldering device for attaching electric leads to multiple terminal block connectors uses power source with one terminal connected to working probe, and other terminal attached to connector carrying common pins for lead insertion. Mating of male and female connectors solders each lead to individual cup pin.

  2. Monolithic Microwave Integrated Circuit (MMIC) Phased Array Demonstrated With ACTS

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Monolithic Microwave Integrated Circuit (MMIC) arrays developed by the NASA Lewis Research Center and the Air Force Rome Laboratory were demonstrated in aeronautical terminals and in mobile or fixed Earth terminals linked with NASA's Advanced Communications Technology Satellite (ACTS). Four K/Ka-band experimental arrays were demonstrated between May 1994 and May 1995. Each array had GaAs MMIC devices at each radiating element for electronic beam steering and distributed power amplification. The 30-GHz transmit array used in uplinks to ACTS was developed by Lewis and Texas Instruments. The three 20-GHz receive arrays used in downlinks from ACTS were developed in cooperation with the Air Force Rome Laboratory, taking advantage of existing Air Force integrated-circuit, active-phased-array development contracts with the Boeing Company and Lockheed Martin Corporation. Four demonstrations, each related to an application of high interest to both commercial and Department of Defense organizations, were conducted. The location, type of link, and the data rate achieved for each of the applications is shown. In one demonstration-- an aeronautical terminal experiment called AERO-X--a duplex voice link between an aeronautical terminal on the Lewis Learjet and ACTS was achieved. Two others demonstrated duplex voice links (and in one case, interactive video links as well) between ACTS and an Army high-mobility, multipurpose wheeled vehicle (HMMWV, or "humvee"). In the fourth demonstration, the array was on a fixed mount and was electronically steered toward ACTS. Lewis served as project manager for all demonstrations and as overall system integrator. Lewis engineers developed the array system including a controller for open-loop tracking of ACTS during flight and HMMWV motion, as well as a laptop data display and recording system used in all demonstrations. The Jet Propulsion Laboratory supported the AERO-X program, providing elements of the ACTS Mobile Terminal. The successful performance of experimental, proof-of-concept MMIC K/Ka-band arrays developed with U.S. industry in field demonstrations with ACTS indicates that high density MMIC integration at 20 and 30 GHz is indeed feasible. The successful development and demonstration of the MMIC array systems was possible only because of significant intergovernmental and Government/industry cooperation and the high level of teamwork within Lewis. The results provide a strong incentive for continuing the focused development of MMIC-array technology for satellite communications applications, with emphasis on packaging and cost issues, and for continuing the planning and conducting of other appropriate demonstrations or experiments of phased-array technology with ACTS. Given the present pressures on reducing funding for research and development in Government and industry, the extent to which this can be continued in a cooperative manner will determine whether MMIC array technology will make the transition from the proof-of-concept level to the operational system level.

  3. Heat tube device

    NASA Technical Reports Server (NTRS)

    Khattar, Mukesh K. (Inventor)

    1990-01-01

    The present invention discloses a heat tube device through which a working fluid can be circulated to transfer heat to air in a conventional air conditioning system. The heat tube device is disposable about a conventional cooling coil of the air conditioning system and includes a plurality of substantially U-shaped tubes connected to a support structure. The support structure includes members for allowing the heat tube device to be readily positioned about the cooling coil. An actuatable adjustment device is connected to the U-shaped tubes for allowing, upon actuation thereof, for the heat tubes to be simultaneously rotated relative to the cooling coil for allowing the heat transfer from the heat tube device to air in the air conditioning system to be selectively varied.

  4. 46 CFR 111.60-17 - Connections and terminations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices...

  5. 46 CFR 111.60-17 - Connections and terminations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices...

  6. Authomatization of Digital Collection Access Using Mobile and Wireless Data Terminals

    NASA Astrophysics Data System (ADS)

    Leontiev, I. V.

    Information technologies become vital due to information processing needs, database access, data analysis and decision support. Currently, a lot of scientific projects are oriented on database integration of heterogeneous systems. The problem of on-line and rapid access to large integrated systems of digital collections is also very important. Usually users move between different locations, either at work or at home. In most cases users need an efficient and remote access to information, stored in integrated data collections. Desktop computers are unable to fulfill the needs, so mobile and wireless devices become helpful. Handhelds and data terminals are nessessary in medical assistance (they store detailed information about each patient, and helpful for nurses), immediate access to data collections is used in a Highway patrol services (databanks of cars, owners, driver licences). Using mobile access, warehouse operations can be validated. Library and museum items cyclecounting will speed up using online barcode-scanning and central database access. That's why mobile devices - cell phones, PDA, handheld computers with wireless access, WindowsCE and PalmOS terminals become popular. Generally, mobile devices have a relatively slow processor, and limited display capabilities, but they are effective for storing and displaying textual data, recognize user hand-writing with stylus, support GUI. Users can perform operations on handheld terminal, and exchange data with the main system (using immediate radio access, or offline access during syncronization process) for update. In our report, we give an approach for mobile access to data collections, which raises an efficiency of data processing in a book library, helps to control available books, books in stock, validate service charges, eliminate staff mistakes, generate requests for book delivery. Our system uses mobile devices Symbol RF (with radio-channel access), and data terminals Symbol Palm Terminal for batch-processing and synchronization with remote library databases. We discuss the use of PalmOS-compatible devices, and WindowsCE terminals. Our software system is based on modular, scalable three-tier architecture. Additional functionality can be easily customized. Scalability is also supplied by Internet / Intranet technologies, and radio-access points. The base module of the system supports generic warehouse operations: cyclecounting with handheld barcode-scanners, efficient items delivery and issue, item movement, reserving, report generating on finished and in-process operations. Movements are optimized using worker's current location, operations are sorted in a priority order and transmitted to mobile and wireless worker's terminals. Mobile terminals improve of tasks processing control, eliminate staff mistakes, display actual information about main processes, provide data for online-reports, and significantly raise the efficiency of data exchange.

  7. Terminal digit bias is not an issue for properly trained healthcare personnel using manual or semi-automated devices - biomed 2010.

    PubMed

    Butler, Kenneth R; Minor, Deborah S; Benghuzzi, Hamed A; Tucci, Michelle

    2010-01-01

    The objective of this study was to evaluate terminal digit preference in blood pressure (BP) measurements taken from a sample of clinics at a large academic health sciences center. We hypothesized that terminal digit preference would occur more frequently in BP measurements taken with manual mercury sphygmomanometry compared to those obtained with semi-automated instruments. A total of 1,393 BP measures were obtained in 16 ambulatory and inpatient sites by personnel using both mercury (n=1,286) and semi-automated (n=107) devices For the semi-automated devices, a trained observer repeated the patients BP following American Heart Association recommendations using a similar device with a known calibration history. At least two recorded systolic and diastolic blood pressures (average of two or more readings for each) were obtained for all manual mercury readings. Data were evaluated using descriptive statistics and Chi square as appropriate (SPSS software, 17.0). Overall, zero and other terminal digit preference was observed more frequently in systolic (?2 = 883.21, df = 9, p < 0.001) and diastolic readings (?2 = 1076.77, df = 9, p < 0.001) from manual instruments, while all end digits obtained by clinic staff using semi-automated devices were more evenly distributed (?2 = 8.23, df = 9, p = 0.511 for systolic and ?2 = 10.48, df = 9, p = 0.313 for diastolic). In addition to zero digit bias in mercury readings, even numbers were reported with significantly higher frequency than odd numbers. There was no detectable digit preference observed when examining semi-automated measurements by clinic staff or device type for either systolic or diastolic BP measures. These findings demonstrate that terminal digit preference was more likely to occur with manual mercury sphygmomanometry. This phenomenon was most likely the result of mercury column graduation in 2 mm Hg increments producing a higher than expected frequency of even digits.

  8. Photovoltaic device and method

    DOEpatents

    Cleereman, Robert J; Lesniak, Michael J; Keenihan, James R; Langmaid, Joe A; Gaston, Ryan; Eurich, Gerald K; Boven, Michelle L

    2015-01-27

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  9. Photovoltaic device and method

    DOEpatents

    Cleereman, Robert; Lesniak, Michael J.; Keenihan, James R.; Langmaid, Joe A.; Gaston, Ryan; Eurich, Gerald K.; Boven, Michelle L.

    2015-11-24

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  10. System for controlling apnea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holzrichter, John F

    2015-05-05

    An implanted stimulation device or air control device are activated by an external radar-like sensor for controlling apnea. The radar-like sensor senses the closure of the air flow cavity, and associated control circuitry signals (1) a stimulator to cause muscles to open the air passage way that is closing or closed or (2) an air control device to open the air passage way that is closing or closed.

  11. Predicting segregation of wood and bark chips by differences in terminal velocities.

    Treesearch

    John A. Sturos

    1973-01-01

    Presents data on length, width, thickness, moisture content, specific gravity, and terminal velocities of wood and bark chips for eight important pulpwood species. Gives differences in terminal velocities of the wood and bark chips used to predict the degree of segregation possible by air flotation.

  12. A transparent electrochromic metal-insulator switching device with three-terminal transistor geometry

    NASA Astrophysics Data System (ADS)

    Katase, Takayoshi; Onozato, Takaki; Hirono, Misako; Mizuno, Taku; Ohta, Hiromichi

    2016-05-01

    Proton and hydroxyl ion play an essential role for tuning functionality of oxides because their electronic state can be controlled by modifying oxygen off-stoichiometry and/or protonation. Tungsten trioxide (WO3), a well-known electrochromic (EC) material for smart window, is a wide bandgap insulator, whereas it becomes a metallic conductor HxWO3 by protonation. Although one can utilize electrochromism together with metal-insulator (MI) switching for one device, such EC-MI switching cannot be utilized in current EC devices because of their two-terminal structure with parallel-plate configuration. Here we demonstrate a transparent EC-MI switchable device with three-terminal TFT-type structure using amorphous (a-) WO3 channel layer, which was fabricated on glass substrate at room temperature. We used water-infiltrated nano-porous glass, CAN (calcium aluminate with nano-pores), as a liquid-leakage-free solid gate insulator. At virgin state, the device was fully transparent in the visible-light region. For positive gate voltage, the active channel became dark blue, and electrical resistivity of the a-WO3 layer drastically decreased with protonation. For negative gate voltage, deprotonation occurred and the active channel returned to transparent insulator. Good cycleability of the present transparent EC-MI switching device would have potential for the development of advanced smart windows.

  13. Reconfigurable electronics using conducting metal-organic frameworks

    DOEpatents

    Allendorf, Mark D.; Talin, Albert Alec; Leonard, Francois; Stavila, Vitalie

    2017-07-18

    A device including a porous metal organic framework (MOF) disposed between two terminals, the device including a first state wherein the MOF is infiltrated by a guest species to form an electrical path between the terminals and a second state wherein the electrical conductivity of the MOF is less than the electrical conductivity in the first state. A method including switching a porous metal organic framework (MOF) between two terminals from a first state wherein a metal site in the MOF is infiltrated by a guest species that is capable of charge transfer to a second state wherein the MOF is less electrically conductive than in the first state.

  14. Linear transmitter design for MSAT terminals

    NASA Technical Reports Server (NTRS)

    Wilkinson, Ross; Macleod, John; Beach, Mark; Bateman, Andrew

    1990-01-01

    One of the factors that will undoubtedly influence the choice of modulation format for mobile satellites, is the availability of cheap, power-efficient, linear amplifiers for mobile terminal equipment operating in the 1.5-1.7 GHz band. Transmitter linearity is not easily achieved at these frequencies, although high power (20W) class A/AB devices are becoming available. However, these components are expensive and require careful design to achieve a modest degree of linearity. In this paper an alternative approach to radio frequency (RF) power amplifier design for mobile satellite (MSAT) terminals using readily-available, power-efficient, and cheap class C devices in a feedback amplifier architecture is presented.

  15. Method of making high breakdown voltage semiconductor device

    DOEpatents

    Arthur, Stephen D.; Temple, Victor A. K.

    1990-01-01

    A semiconductor device having at least one P-N junction and a multiple-zone junction termination extension (JTE) region which uniformly merges with the reverse blocking junction is disclosed. The blocking junction is graded into multiple zones of lower concentration dopant adjacent termination to facilitate merging of the JTE to the blocking junction and placing of the JTE at or near the high field point of the blocking junction. Preferably, the JTE region substantially overlaps the graded blocking junction region. A novel device fabrication method is also provided which eliminates the prior art step of separately diffusing the JTE region.

  16. Moral and Legal Issues Surrounding Terminal Sedation and Physician Assisted Suicide

    DTIC Science & Technology

    2002-09-23

    1 MORAL AND LEGAL ISSUES SURROUNDING TERMINAL SEDATION AND PHYSICIAN ASSISTED SUICIDE by CONSTANCE ReJENNA BRADLEY B.S., United States Air Force...Title and Subtitle Moral and Legal Issues Surrounding Terminal Sedation and Physician-Assisted Suicide Contract Number Grant Number Program...Constance ReJenna (M.A., Philosophy) Moral and Legal Issues Surrounding Terminal Sedation and Physician Assisted Suicide Thesis directed by Instructor

  17. Apparatus for supplying conditioned air at a substantially constant temperature and humidity

    NASA Technical Reports Server (NTRS)

    Obler, H. D. (Inventor)

    1980-01-01

    The apparatus includes a supply duct coupled to a source of supply air for carrying the supply air therethrough. A return duct is coupled to the supply duct for carrying return conditioned air therethrough. A temperature reducing device is coupled to the supply duct for decreasing the temperature of the supply and return conditioned air. A by-pass duct is coupled to the supply duct for selectively directing portions of the supply and return conditioned air around the temperature reducing device. Another by-pass duct is coupled to the return duct for selectively directing portions of the return conditioned air around the supply duct and the temperature reduction device. Controller devices selectively control the flow and amount of mixing of the supply and return conditioned air.

  18. 42 CFR 84.143 - Terminal fittings or chambers; Type B supplied-air respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF... supplied-air respirators; minimum requirements. (a) Blowers or connections to air supplies providing...

  19. Interconnected semiconductor devices

    DOEpatents

    Grimmer, Derrick P.; Paulson, Kenneth R.; Gilbert, James R.

    1990-10-23

    Semiconductor layer and conductive layer formed on a flexible substrate, divided into individual devices and interconnected with one another in series by interconnection layers and penetrating terminals.

  20. 40 CFR 60.5215 - By what date must I conduct annual air pollution control device inspections and make any...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pollution control device inspections and make any necessary repairs? 60.5215 Section 60.5215 Protection of... air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution control device used to comply with the emission limits, according...

  1. Evaluation of a Terminal Area In-Trail Approach Spacing, Project and Study

    NASA Technical Reports Server (NTRS)

    Shelden, Stephen; Johnson, Walter (Editor)

    2001-01-01

    Reported here are the results of work completed as a precursor to Distributed Air Ground (DAG), Concept Element 11 (CE11) research. CE11 is a NASA, Advanced Air Transportation Technologies (AATT) concept initiated to promote research on in-trail merging and spacing during approach in the terminal area environment, such that improvements to the National Air Space (NAS) may be realized. A description of the project concept, results of a preliminary study, and a literature review are presented. In terms of conclusions, study results, and reference material respectively: 1) the concept is supported as being significant to NAS capacity improvement, 2) the preliminary study indicated that having more than one downstream, in-trail aircraft present on a CDTI during approach may be advantageous, and that flying traditional Standard Terminal Arrival Routes (STAR) utilizing advanced decision support tools (DST) may be complicated by wake turbulence considerations, a lack of vertical awareness on the part of the flight crew, and the 'step-down' nature of many terminal area approaches, and 3) the results of a literature review are presented for future reference.

  2. 40 CFR 60.4895 - By what date must I conduct annual air pollution control device inspections and make any...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...

  3. 40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... Compliance Requirements § 60.2151 By what date must I conduct the annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control...

  4. 40 CFR 60.4895 - By what date must I conduct annual air pollution control device inspections and make any...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...

  5. 40 CFR 60.2151 - By what date must I conduct the annual air pollution control device inspection?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air pollution control device inspection? 60.2151 Section 60.2151 Protection of Environment... Compliance Requirements § 60.2151 By what date must I conduct the annual air pollution control device inspection? On an annual basis (no more than 12 months following the previous annual air pollution control...

  6. 40 CFR 60.4895 - By what date must I conduct annual air pollution control device inspections and make any...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution... following the previous annual air pollution control device inspection. (b) Within 10 operating days...

  7. Thermal and bias cycling stabilizes planar silicon devices

    NASA Technical Reports Server (NTRS)

    Harris, R. E.; Meinhard, J. E.

    1967-01-01

    Terminal burn-in or baking step time in the processing of planar silicon devices is extended to reduce their inversion tendencies. The collector-base junction of the device is also cyclically biased during the burn-in.

  8. [Effect of combustion devices on the quality of indoor air].

    PubMed

    Ulbrich, G

    1982-01-01

    Combustion devices and the equipment conducting their effluent gases such as ducts and chimneys are factors which might have an unreasonable or even dangerous impact on the quality of air inside buildings. There is a danger of flue gases entering the indoor environment during the heating process (a) if the air-circulation associated with the operation of a combustion device is disturbed or even interrupted, (b) if the air stream - as far as flue gases are involved - flows under elevated pressure, and (c) if the combustion device and the flue gas conducting equipment are not leak-proof. These three cases and their influence on indoor air quality are extensively discussed. In the German Combustion Device Code from 1980 care is taken to minimize the pollutant concentrations in rooms with combustion devices by setting special requirements for the room in which the device is located, and by prescribing the standardization of the technical characteristics of chimneys and combustion devices.

  9. Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system--a human response study in hot and humid climate.

    PubMed

    Yang, B; Sekhar, S C; Melikov, A K

    2010-08-01

    The benefits of thermal comfort and indoor air quality with personalized ventilation (PV) systems have been demonstrated in recent studies. One of the barriers for wide spread acceptance by architects and HVAC designers has been attributed to challenges and constraints faced in the integration of PV systems with the work station. A newly developed ceiling-mounted PV system addresses these challenges and provides a practical solution while retaining much of the apparent benefits of PV systems. Assessments of thermal environment, air movement, and air quality for ceiling-mounted PV system were performed with tropically acclimatized subjects in a Field Environmental Chamber. Thirty-two subjects performed normal office work and could choose to be exposed to four different PV airflow rates (4, 8, 12, and 16 L/s), thus offering themselves a reasonable degree of individual control. Ambient temperatures of 26 and 23.5 degrees C and PV air temperatures of 26, 23.5, and 21 degrees C were employed. The local and whole body thermal sensations were reduced when PV airflow rates were increased. Inhaled air temperature was perceived cooler and perceived air quality and air freshness improved when PV airflow rate was increased or temperature was reduced. The newly developed ceiling-mounted PV system offers a practical solution to the integration of PV air terminal devices (ATDs) in the vicinity of the workstation. By remotely locating the PV ATDs on the ceiling directly above the occupants and under their control, the conditioned outdoor air is now provided to the occupants through the downward momentum of the air. A secondary air-conditioning and air distribution system offers additional cooling in the room and maintains a higher ambient temperature, thus offering significant benefits in conserving energy. The results of this study provide designers and consultants with needed knowledge for design of PV systems.

  10. Analysis of Ti valence states in resistive switching regions of a rutile TiO2‑ x four-terminal memristive device

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Kengo; Takeuchi, Shotaro; Tohei, Tetsuya; Ikarashi, Nobuyuki; Sakai, Akira

    2018-06-01

    We have performed Ti valence state analysis of our four-terminal rutile TiO2‑ x single-crystal memristors using scanning transmission electron microscopy–electron energy loss spectroscopy (STEM–EELS). Analysis of Ti-L2,3 edge EELS spectra revealed that the electrocolored region formed by the application of voltage includes a valence state reflecting highly reduced TiO2‑ x due to the accumulation of oxygen vacancies. Such a valence state mainly exists within ∼50 nm from the crystal surface and extends along specific crystal directions. These electrically reduced surface layers are considered to directly contribute to the resistive switching (RS) in the four-terminal device. The present results add new insights into the microscopic mechanisms of the RS phenomena and should contribute to further development and improvements of TiO2‑ x based memristive devices.

  11. 46 CFR 56.50-90 - Sounding devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... be provided with a suitable means of determining liquid level. Except for a main cargo tank on a tank... fuel-oil tank may terminate in any space where the risk of ignition of spillage from the pipe might arise. None may terminate in a space for passengers or crew. When practicable, none may terminate in a...

  12. 77 FR 67833 - Certain Radio Frequency Integrated Circuits and Devices Containing Same; Notice of Commission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-14

    ... Determination Terminating the Investigation in its Entirety AGENCY: U.S. International Trade Commission. ACTION.... 9) granting the complainant's unopposed motion to terminate the investigation in its entirety based... Peregrine filed an unopposed motion pursuant to Commission Rule 210.21(a)(1) to terminate the investigation...

  13. Human Factors Assessment: The Passive Final Approach Spacing Tool (pFAST) Operational Evaluation

    NASA Technical Reports Server (NTRS)

    Lee, Katharine K.; Sanford, Beverly D.

    1998-01-01

    Automation to assist air traffic controllers in the current terminal and en route air traff ic environments is being developed at Ames Research Center in conjunction with the Federal Aviation Administration. This automation, known collectively as the Center-TRACON Automation System (CTAS), provides decision- making assistance to air traffic controllers through computer-generated advisories. One of the CTAS tools developed specifically to assist terminal area air traffic controllers is the Passive Final Approach Spacing Tool (pFAST). An operational evaluation of PFAST was conducted at the Dallas/Ft. Worth, Texas, Terminal Radar Approach Control (TRACON) facility. Human factors data collected during the test describe the impact of the automation upon the air traffic controller in terms of perceived workload and acceptance. Results showed that controller self-reported workload was not significantly increased or reduced by the PFAST automation; rather, controllers reported that the levels of workload remained primarily the same. Controller coordination and communication data were analyzed, and significant differences in the nature of controller coordination were found. Controller acceptance ratings indicated that PFAST was acceptable. This report describes the human factors data and results from the 1996 Operational Field Evaluation of Passive FAST.

  14. Remote possibly hazardous content container sampling device

    DOEpatents

    Volz, David L.

    1998-01-01

    The present invention relates to an apparatus capable of sampling enclosed containers, where the contents of the container is unknown. The invention includes a compressed air device capable of supplying air pressure, device for controlling the amount of air pressure applied, a pneumatic valve, a sampling device having a hollow, sampling insertion needle suspended therein and device to communicate fluid flow between the container and a containment vessel, pump or direct reading instrument.

  15. Modeling of terminal-area airplane fuel consumption

    DOT National Transportation Integrated Search

    2009-08-01

    Accurate modeling of airplane fuel consumption is necessary for air transportation policy-makers to properly : adjudicate trades between competing environmental and economic demands. Existing public models used for : computing terminal-area airplane ...

  16. 32 CFR 842.99 - Compromise, termination, and suspension of collection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Compromise, termination, and suspension of collection. 842.99 Section 842.99 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR... States (31 U.S.C. 3701, 3711-3719) § 842.99 Compromise, termination, and suspension of collection. This...

  17. Air removal device. [life support systems

    NASA Technical Reports Server (NTRS)

    Booth, F. W.; Bruce, R. A.

    1981-01-01

    The disclosure concerns a device suitable for removing air from water under both zero and one 'g' gravity conditions. The device is comprised of a pair of spaced membranes on being hydrophobic and the other being hydrophilic. The air-water mixture is introduced into the space therebetween, and the selective action of the membranes yields removal of the air from the water.

  18. 21 CFR 874.1800 - Air or water caloric stimulator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Air or water caloric stimulator. 874.1800 Section 874.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Diagnostic Devices § 874.1800 Air or water caloric stimulator. (a) Identification. An air or wate...

  19. Concept of Operations for the Next Generation Air Transportation System, Version 2.0

    DTIC Science & Technology

    2007-06-13

    SIDA )/airport operations area (AOA), [R-110] terminal perimeter, terminal airspace (security) • Landside. Terminal public and commercial roadways and...Required Surveillance Performance RTSS Remote Terminal Security Screening SAA Special Activity Airspace SIDA Security Identification Display Area SM...impede airside operations? R-110 Research 6.4.2/C. 4.4.1 Airside: Security Identification Display Area ( SIDA )/AOA R&D needed to develop and

  20. Computer and visual display terminals (VDT) vision syndrome (CVDTS).

    PubMed

    Parihar, J K S; Jain, Vaibhav Kumar; Chaturvedi, Piyush; Kaushik, Jaya; Jain, Gunjan; Parihar, Ashwini K S

    2016-07-01

    Computer and visual display terminals have become an essential part of modern lifestyle. The use of these devices has made our life simple in household work as well as in offices. However the prolonged use of these devices is not without any complication. Computer and visual display terminals syndrome is a constellation of symptoms ocular as well as extraocular associated with prolonged use of visual display terminals. This syndrome is gaining importance in this modern era because of the widespread use of technologies in day-to-day life. It is associated with asthenopic symptoms, visual blurring, dry eyes, musculoskeletal symptoms such as neck pain, back pain, shoulder pain, carpal tunnel syndrome, psychosocial factors, venous thromboembolism, shoulder tendonitis, and elbow epicondylitis. Proper identification of symptoms and causative factors are necessary for the accurate diagnosis and management. This article focuses on the various aspects of the computer vision display terminals syndrome described in the previous literature. Further research is needed for the better understanding of the complex pathophysiology and management.

  1. Process yield improvements with process control terminal for varian serial ion implanters

    NASA Astrophysics Data System (ADS)

    Higashi, Harry; Soni, Ameeta; Martinez, Larry; Week, Ken

    Implant processes in a modern wafer production fab are extremely complex. There can be several types of misprocessing, i.e. wrong dose or species, double implants and missed implants. Process Control Terminals (PCT) for Varian 350Ds installed at Intel fabs were found to substantially reduce the number of misprocessing steps. This paper describes those misprocessing steps and their subsequent reduction with use of PCTs. Reliable and simple process control with serial process ion implanters has been in increasing demand. A well designed process control terminal greatly increases device yield by monitoring all pertinent implanter functions and enabling process engineering personnel to set up process recipes for simple and accurate system operation. By programming user-selectable interlocks, implant errors are reduced and those that occur are logged for further analysis and prevention. A process control terminal should also be compatible with office personal computers for greater flexibility in system use and data analysis. The impact from the capability of a process control terminal is increased productivity, ergo higher device yield.

  2. Numerical Simulation on the Induced Voltage Across the Coil Terminal by the Segmented Flow of Ferrofluid and Air-Layer.

    PubMed

    Lee, Won-Ho; Lee, Sangyoup; Lee, Jong-Chul

    2018-09-01

    Nanoparticles and nanofluids have been implemented in energy harvesting devices, and energy harvesting based on magnetic nanofluid flow was recently achieved by using a layer-built magnet and microbubble injection to induce a voltage on the order of 10-1 mV. However, this is not yet suitable for some commercial purpose. The air bubbles must be segmented in the base fluid, and the magnetic flux of the ferrofluids should change over time to increase the amount of electric voltage and current from energy harvesting. In this study, we proposed a novel technique to achieve segmented flow of the ferrofluids and the air layers. This segmented ferrofluid flow linear generator can increase the magnitude of the induced voltage from the energy harvesting system. In our experiments, a ferrofluid-filled capsule produced time-dependent changes in the magnetic flux through a multi-turn coil, and the induced voltage was generated on the order of about 101 mV at a low frequency of 2 Hz. A finite element analysis was used to describe the time-dependent change of the magnetic flux through the coil according to the motion of the segmented flow of the ferrofluid and the air-layer, and the induced voltage was generated to the order of 102 mV at a high frequency of 12.5 Hz.

  3. Multi-junction Thin-film Solar Cells on Flexible Substrates for Space Power

    NASA Technical Reports Server (NTRS)

    Hepp, Aloysius F.; Smith, Mark; Scofield, John H.; Dickman, John E.; Lush, Gregory B.; Morel, Donald L.; Ferekides, Christos; Dhere, Neelkanth G.

    2002-01-01

    The ultimate objective of the thin-film program at NASA GRC is development of a 20 percent AM0 thin-film device technology with high power/weight ratio. Several approaches are outlined to improve overall device efficiency and power/weight ratio. One approach involves the use of very lightweight flexible substrates such as polyimides (i.e., Kapton(Trademark)) or metal foil. Also, a compound semiconductor tandem device structure that can meet this objective is proposed and simulated using Analysis of Microelectronic and Photonic Structures (AMPS). AMPS modeling of current devices in tandem format indicate that AM0 efficiencies near 20 percent can be achieved. And with improvements in materials, efficiencies approaching 25 percent are achievable. Several important technical issues need to be resolved to realize these complex devices: development of a wide bandgap material with good electronic properties, development of transparent contacts, and targeting a 2-terminal device structure (with more complicated processing and tunnel junction) or 4-terminal device. Recent progress in the NASA GRC program is outlined.

  4. Development of a compact wearable pneumatic drive unit for a ventricular assist device.

    PubMed

    Homma, Akihiko; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Akagawa, Eiki; Lee, Hwansung; Nishinaka, Tomohiro; Takewa, Yoshiaki; Mizuno, Toshihide; Tsukiya, Tomonori; Kakuta, Yukihide; Katagiri, Nobumasa; Shimosaki, Isao; Hamada, Shigeru; Mukaibayashi, Hiroshi; Iwaoka, Wataru

    2008-01-01

    The purpose of this study was to develop a compact wearable pneumatic drive unit for a ventricular assist device (VAD). This newly developed drive unit, 20 x 8.5 x 20 cm in size and weighing approximately 1.8 kg, consists of a brushless DC motor, noncircular gears, a crankshaft, a cylinder-piston, and air pressure regulation valves. The driving air pressure is generated by the reciprocating motion of the piston and is controlled by the air pressure regulation valves. The systolic ratio is determined by the noncircular gears, and so is fixed for a given configuration. As a result of an overflow-type mock circulation test, a drive unit with a 44% systolic ratio connected to a Toyobo VAD blood pump with a 70-ml stroke volume achieved a pump output of more than 7 l/min at 100 bpm against a 120 mmHg afterload. Long-term animal tests were also performed using drive units with systolic ratios of 45% and 53% in two Holstein calves weighing 62 kg and 74 kg; the tests were terminated on days 30 and 39, respectively, without any malfunction. The mean aortic pressure, bypass flow, and power consumption for the first calf were maintained at 90 x 13 mmHg, 3.9 x 0.9 l/min, and 12 x 1 W, and those for the second calf were maintained at 88 x 13 mmHg, 5.0 x 0.5 l/min, and 16 x 2 W, respectively. These results indicate that the newly developed drive unit may be used as a wearable pneumatic drive unit for the Toyobo VAD blood pump.

  5. Gating electrical transport through DNA molecules that bridge between silicon nanogaps.

    PubMed

    Takagi, Shogo; Takada, Tadao; Matsuo, Naoto; Yokoyama, Shin; Nakamura, Mitsunobu; Yamana, Kazushige

    2012-03-21

    DNA electronic devices were prepared on silicon-based three-terminal electrodes. Both ends of DNA molecules (400 bp long, mixed sequences) were bridged via chemical bonds between the source-drain nanogap (120 nm) electrodes. S-Shaped I-V curves were obtained and the electric current can be modulated by the gate voltage. The DNA molecules act as semiconducting p-type nanowires in the three-terminal device. This journal is © The Royal Society of Chemistry 2012

  6. 9 CFR 3.65 - Terminal facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., or air conditioning and may be ventilated or air circulated by means of fans, blowers, or an air conditioning system so as to minimize drafts, odors, and moisture condensation. Auxiliary ventilation, such as exhaust fans and vents or fans or blowers or air conditioning shall be used for any animal holding area...

  7. A simple novel device for air sampling by electrokinetic capture

    DOE PAGES

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; ...

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.« less

  8. A simple novel device for air sampling by electrokinetic capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.« less

  9. A simple novel device for air sampling by electrokinetic capture.

    PubMed

    Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A

    2015-12-27

    A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87 %, with the reference filter taken as "gold standard." Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. The performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.

  10. Silicon nanocrystal inks, films, and methods

    DOEpatents

    Wheeler, Lance Michael; Kortshagen, Uwe Richard

    2015-09-01

    Silicon nanocrystal inks and films, and methods of making and using silicon nanocrystal inks and films, are disclosed herein. In certain embodiments the nanocrystal inks and films include halide-terminated (e.g., chloride-terminated) and/or halide and hydrogen-terminated nanocrystals of silicon or alloys thereof. Silicon nanocrystal inks and films can be used, for example, to prepare semiconductor devices.

  11. 21 CFR 26.80 - Entry into force, amendment, and termination.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Entry into force, amendment, and termination. 26... EUROPEAN COMMUNITY âFrameworkâ Provisions § 26.80 Entry into force, amendment, and termination. (a) The...) inspections, and medical devices shall enter into force on the first day of the second month following the...

  12. Low inductance connector assembly

    DOEpatents

    Holbrook, Meghan Ann; Carlson, Douglas S

    2013-07-09

    A busbar connector assembly for coupling first and second terminals on a two-terminal device to first and second contacts on a power module is provided. The first terminal resides proximate the first contact and the second terminal resides proximate the second contact. The assembly comprises a first bridge having a first end configured to be electrically coupled to the first terminal, and a second end configured to be electrically coupled to the second contact, and a second bridge substantially overlapping the first bridge and having a first end electrically coupled to the first contact, and a second end electrically coupled to the second terminal.

  13. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...

  14. 21 CFR 890.5160 - Air-fluidized bed.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Air-fluidized bed. 890.5160 Section 890.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5160 Air-fluidized bed. (a...

  15. 21 CFR 890.5160 - Air-fluidized bed.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Air-fluidized bed. 890.5160 Section 890.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5160 Air-fluidized bed. (a...

  16. 21 CFR 890.5160 - Air-fluidized bed.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Air-fluidized bed. 890.5160 Section 890.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5160 Air-fluidized bed. (a...

  17. 21 CFR 890.5160 - Air-fluidized bed.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Air-fluidized bed. 890.5160 Section 890.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5160 Air-fluidized bed. (a...

  18. 21 CFR 890.5160 - Air-fluidized bed.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Air-fluidized bed. 890.5160 Section 890.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5160 Air-fluidized bed. (a...

  19. 40 CFR 424.20 - Applicability; description of the covered electric furnaces and other smelting operations with...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...

  20. 40 CFR 424.20 - Applicability; description of the covered electric furnaces and other smelting operations with...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...

  1. 40 CFR 424.20 - Applicability; description of the covered electric furnaces and other smelting operations with...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...

  2. 40 CFR 424.20 - Applicability; description of the covered electric furnaces and other smelting operations with...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...

  3. 40 CFR 424.20 - Applicability; description of the covered electric furnaces and other smelting operations with...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...

  4. KCBX Quality Assurance Project Plan - October 2014

    EPA Pesticide Factsheets

    This revised plan's standards for data quality, sampling and testing methods, and task management guide the implementation of Ambient Air Monitoring by URS Corporation at the KCBX Terminals Company North and South Terminals in Chicago, Ill.

  5. KCBX Quality Assurance Project Plan - February 2014

    EPA Pesticide Factsheets

    This plan's standards for data quality, sampling and testing methods, and task management guide the implementation of Ambient Air Monitoring, by URS Corporation, at the KCBX Terminals Company North and South Terminals in Chicago, IL.

  6. 21 CFR 880.6890 - General purpose disinfectants.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... prior to terminal sterilization or high level disinfection. Noncritical medical devices make only topical contact with intact skin. (b) Classification. Class I (general controls). The device is exempt...

  7. The Influence of Water Vapor on the Stability and Processing of Hybrid Perovskite Solar Cells Made from Non-Stoichiometric Precursor Mixtures.

    PubMed

    Petrus, Michiel L; Hu, Yinghong; Moia, Davide; Calado, Philip; Leguy, Aurélien M A; Barnes, Piers R F; Docampo, Pablo

    2016-09-22

    We investigated the influence of moisture on methylammonium lead iodide perovskite (MAPbI 3 ) films and solar cells derived from non-stoichiometric precursor mixtures. We followed both the structural changes under controlled air humidity through in situ X-ray diffraction, and the electronic behavior of devices prepared from these films. A small PbI 2 excess in the films improved the stability of the perovskite compared to stoichiometric samples. We assign this to excess PbI 2 layers at the perovskite grain boundaries or to the termination of the perovskite crystals with Pb and I. In contrast, the MAI-excess films composed of smaller perovskite crystals showed increased electronic disorder and reduced device performance owing to poor charge collection. Upon exposure to moisture followed by dehydration (so-called solvent annealing), these films recrystallized to form larger, highly oriented crystals with fewer electronic defects and a remarkable improvement in photocurrent and photovoltaic efficiency. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. CPAP Devices for Emergency Prehospital Use: A Bench Study.

    PubMed

    Brusasco, Claudia; Corradi, Francesco; De Ferrari, Alessandra; Ball, Lorenzo; Kacmarek, Robert M; Pelosi, Paolo

    2015-12-01

    CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model the performance of 3 orofacial mask devices (Ventumask, EasyVent, and Boussignac CPAP system) and 2 helmets (Ventukit and EVE Coulisse) used to apply CPAP in the prehospital setting. A static test evaluated air-flow output, positive pressure applied, and FIO2 delivered by each device. A dynamic test assessed airway pressure stability during simulated ventilation. Efficiency of devices was compared based on oxygen flow needed to generate a minimum air flow of 60 L/min at each CPAP setting. The EasyVent and EVE Coulisse devices delivered significantly higher mean air-flow outputs compared with the Ventumask and Ventukit under all CPAP conditions tested. The Boussignac CPAP system never reached an air-flow output of 60 L/min. The EasyVent had significantly lower pressure excursion than the Ventumask at all CPAP levels, and the EVE Coulisse had lower pressure excursion than the Ventukit at 5, 15, and 20 cm H2O, whereas at 10 cm H2O, no significant difference was observed between the 2 devices. Estimated oxygen consumption was lower for the EasyVent and EVE Coulisse compared with the Ventumask and Ventukit. Air-flow output, pressure applied, FIO2 delivered, device oxygen consumption, and ability to maintain air flow at 60 L/min differed significantly among the CPAP devices tested. Only the EasyVent and EVE Coulisse achieved the required minimum level of air-flow output needed to ensure an effective therapy under all CPAP conditions. Copyright © 2015 by Daedalus Enterprises.

  9. Forced-air warming design: evaluation of intake filtration, internal microbial buildup, and airborne-contamination emissions.

    PubMed

    Reed, Mike; Kimberger, Oliver; McGovern, Paul D; Albrecht, Mark C

    2013-08-01

    Forced-air warming devices are effective for the prevention of surgical hypothermia. However, these devices intake nonsterile floor-level air, and it is unknown whether they have adequate filtration measures to prevent the internal buildup or emission of microbial contaminants. We rated the intake filtration efficiency of a popular current-generation forced-air warming device (Bair Hugger model 750, Arizant Healthcare) using a monodisperse sodium chloride aerosol in the laboratory. We further sampled 23 forced-air warming devices (same model) in daily hospital use for internal microbial buildup and airborne-contamination emissions via swabbing and particle counting. Laboratory testing found the intake filter to be 63.8% efficient. Swabbing detected microorganisms within 100% of the forced-air warming blowers sampled, with isolates of coagulase-negative staphylococci, mold, and micrococci identified. Particle counting showed 96% of forced-air warming blowers to be emitting significant levels of internally generated airborne contaminants out of the hose end. These findings highlight the need for upgraded intake filtration, preferably high-efficiency particulate air filtration (99.97% efficient), on current-generation forced-air warming devices to reduce contamination buildup and emission risks.

  10. 77 FR 32996 - Certain Handheld Electronic Computing Devices, Related Software, and Components Thereof...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-04

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-769] Certain Handheld Electronic Computing Devices, Related Software, and Components Thereof; Termination of the Investigation Based on... electronic computing devices, related software, and components thereof by reason of infringement of certain...

  11. Study of radioisotope safety devices for electric propulsion system, Volume 1: Summary report

    NASA Technical Reports Server (NTRS)

    Bradshaw, G. B.; Homeyer, W. G.; Postula, F. D.; Steeger, E. J.

    1972-01-01

    A new reference design was prepared for the 5 kW(e) thermionic power supply. The safety equipment in this design is a passive containment system which does not rely on the operation of any mechanisms such as a launch escape rocket or deployment of parachutes. It includes: (1) a blast shield to protect against the explosion of the launch vehicle; (2) a combination of refractory thermal insulation and heat storage material to protect against a sustained launch pad fire; (3) a reentry body with a spherical nose and a large conical flare at the aft end to stabilize the reentry attitude and lower the terminal velocity in air; (4) composite graphite thermal protection to sustain the reentry heat pulse; (5) crushable honeycomb behind the nose to limit the deceleration of the radioisotope source due to impact on land at terminal velocity; (6) a double-walled secondary containment vessel surrounding the isotopic capsules; (7) neutron shielding to reduce external dose rates; (8) an auxiliary cooling system employing redundant heat pipes to remove the radioactive decay heat from the heat source and reject it to the surroundings or to a forced convection loop.

  12. Method for fabricating an interconnected array of semiconductor devices

    DOEpatents

    Grimmer, Derrick P.; Paulson, Kenneth R.; Gilbert, James R.

    1989-10-10

    Semiconductor layer and conductive layer formed on a flexible substrate, divided into individual devices and interconnected with one another in series by interconnection layers and penetrating terminals.

  13. CAMAC: A Unique Application with a Pocket Terminal.

    DTIC Science & Technology

    1982-09-16

    POCKET TERMINAL S. PERFORMING ORG. REPORT NUMSIER I. AUTWOR(o) S. CONTRACT OR GRANT NUMU41’e() A.D. Elmond S. PERFORMING ORGANIZATION NAME AND ADORIESS 10...port of any CAMAC crate. In addition to being a maintenance device, the HHTT is a " smart " device that can control operations in a CAMAC crate. The...system LSI 11/23 microprocessor through an Asynchronous Serial Port (ASP) interface module. This ASP interface consists of: 1) Crystal Clock 2) MIK -Bus

  14. Monolithic tandem solar cell

    DOEpatents

    Wanlass, Mark W.

    1991-01-01

    A single-crystal, monolithic, tandem, photovoltaic solar cell is described which includes (a) an InP substrate having upper and lower surfaces, (b) a first photoactive subcell on the upper surface of the InP substrate, and (c) a second photoactive subcell on the first subcell. The first photoactive subcell is GaInAsP of defined composition. The second subcell is InP. The two subcells are lattice matched. The solar cell can be provided as a two-terminal device or a three-terminal device.

  15. Absolute Negative Resistance Induced by Directional Electron-Electron Scattering in a Two-Dimensional Electron Gas

    NASA Astrophysics Data System (ADS)

    Kaya, Ismet I.; Eberl, Karl

    2007-05-01

    A three-terminal device formed by two electrostatic barriers crossing an asymmetrically patterned two-dimensional electron gas displays an unusual potential depression at the middle contact, yielding absolute negative resistance. The device displays momentum and current transfer ratios that far exceed unity. The observed reversal of the current or potential in the middle terminal can be interpreted as the analog of Bernoulli’s effect in a Fermi liquid. The results are explained by directional scattering of electrons in two dimensions.

  16. Airport Airside System Model

    DOT National Transportation Integrated Search

    1971-06-01

    The model of an airport airside system simulates aircraft operations and controller functions in the terminal area, both in the air and on the ground. The model encompasses all operations between the terminal gate and the point of handoff between the...

  17. 40 CFR 60.471 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  18. 40 CFR 60.471 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  19. 40 CFR 60.471 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  20. 40 CFR 60.471 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  1. 40 CFR 60.471 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  2. Reduction of Weather-Related Terminal Area Delays in the Free-Flight Era

    NASA Technical Reports Server (NTRS)

    Johnson, Sally C.; Chin, David K.; Rovinsky, Robert B.; Kostiuk, Peter F.; Lee, David A.; Hemm, Robert V.; Wingrove, Earl R., III

    1996-01-01

    While much of the emphasis of the free-flight movement has been concentrated on reducing en-route delays, airport capacity is a major bottleneck in the current airspace system, particularly during bad weather. According to the Air Transport Association (ATA) Air Carrier Delay Reports, ground delays (gate-hold, taxi-in, and taxi-out) comprise 75 percent of total delays. It is likely that the projected steady growth in traffic will only exacerbate these losses. Preliminary analyses show that implementation of the terminal area technologies and procedures under development in NASA s Terminal Area Productivity program can potentially save the airlines at least $350M annually in weather-related delays by the year 2005 at Boston Logan and Detroit airports alone. This paper briefly describes the Terminal Area Productivity program, outlines the costhenefit analyses that are being conducted in support of the program, and presents some preliminary analysis results.

  3. 40 CFR 60.5250 - What definitions must I know?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... used for discharging combustion gases to avoid severe damage to the air pollution control device or..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by...). (2) A change in the air pollution control devices used to comply with the emission limits for the...

  4. 40 CFR 60.4930 - What definitions must I know?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... stack means a device used for discharging combustion gases to avoid severe damage to the air pollution..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by... sludge prior to incineration). (2) A change in the air pollution control devices used to comply with the...

  5. 40 CFR 60.4930 - What definitions must I know?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... stack means a device used for discharging combustion gases to avoid severe damage to the air pollution..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by... sludge prior to incineration). (2) A change in the air pollution control devices used to comply with the...

  6. 40 CFR 60.5250 - What definitions must I know?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... used for discharging combustion gases to avoid severe damage to the air pollution control device or..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by...). (2) A change in the air pollution control devices used to comply with the emission limits for the...

  7. 40 CFR 60.5250 - What definitions must I know?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... used for discharging combustion gases to avoid severe damage to the air pollution control device or..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by...). (2) A change in the air pollution control devices used to comply with the emission limits for the...

  8. 40 CFR 60.4930 - What definitions must I know?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... stack means a device used for discharging combustion gases to avoid severe damage to the air pollution..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by... sludge prior to incineration). (2) A change in the air pollution control devices used to comply with the...

  9. 40 CFR 60.5250 - What definitions must I know?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... used for discharging combustion gases to avoid severe damage to the air pollution control device or..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by...). (2) A change in the air pollution control devices used to comply with the emission limits for the...

  10. 40 CFR 60.4930 - What definitions must I know?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... stack means a device used for discharging combustion gases to avoid severe damage to the air pollution..., 2010. Fabric filter means an add-on air pollution control device used to capture particulate matter by... sludge prior to incineration). (2) A change in the air pollution control devices used to comply with the...

  11. 78 FR 19606 - Energy Conservation Program for Consumer Products: Test Procedures for Residential Furnace Fans

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-02

    ... electrically-powered devices used in central HVAC systems for the purposes of circulating air through ductwork...- powered device used in a central HVAC system for the purpose of circulating air through ductwork. DOE... included single-phase, electrically-powered devices that circulate air through ductwork in HVAC systems...

  12. A new device for evacuating air from the cardiac chambers.

    PubMed Central

    Zhong, B T

    1993-01-01

    A new device has been developed to provide complete de-airing of the heart after cardiopulmonary bypass. The apparatus consists of a special aspiration needle threaded to the bottom of a transparent bulb. A 1-way flutter valve is mounted at the top of the bulb, which creates a vacuum when the bulb is squeezed. This device has been used in 4 adults and 2 children, for both congenital and acquired heart disease. Preliminary results have shown that this device's active suctioning of air results in effective removal of air from the cardiac chambers; the transparent bulb enables the surgeon to visually determine that the de-airing procedure is complete. PMID:8219828

  13. Problems in air traffic management. VII., Job training performance of air traffic control specialists - measurement, structure, and prediction.

    DOT National Transportation Integrated Search

    1965-07-01

    A statistical study of training- and job-performance measures of several hundred Air Traffic Control Specialists (ATCS) representing Enroute, Terminal, and Flight Service Station specialties revealed that training-performance measures reflected: : 1....

  14. Newsroom

    Science.gov Websites

    from Air Force Gen. Lori Robinson during a ceremony held at Peterson Air Force Base today. May 24, 2018 Gen. O'Shaughnessy assumes command of NORAD, USNORTHCOM Peterson Air Force Base, Colo. - Air Force Gen terminal Sept. 22, 2017 at Joint Base San Antonio-Kelly Field. The cargo was being staged at the Federal

  15. Hodoscope readout system

    DOEpatents

    Lee, L.Y.

    1973-12-01

    A readout system has been provided for reading out a radiation multidetector device with a reduced number of signal sensors. A radiation hodoscope, such as an array of scintillation counters, multiwire proportional counter array, or a set of multidetectors which do not receive signals simultaneously, is divided into equal numbered groups. A first group of signal terminals is connected to the equal numbered groups of detectors so that a signal from any one of the detectors of a group will be fed to one of the first group of terminals. A second group of signal terminals is connected to the detector groups so that a signal from a particular numbered detector of each of the detector groups is connected to one of the second group of terminals. Both groups of signal terminals are, in turn, coupled to signal sensors so that when a signal is simultaneously observed in one of the first group of terminals and one of the second group of tenniinals the specific detector detecting a radiation event is determined. The sensors are arranged in such a manner that a binary code is developed from their outputs which can be stored in a digital storage means according to the location of the event in the multidetector device. (Official Gazette)

  16. Strand development and splice device : final report, February 3, 2009.

    DOT National Transportation Integrated Search

    2010-02-01

    "A new device for gripping prestressing strands was developed and tested. The device could provide a means of anchoring the terminal end of a strand in order to provide a mechanism for developing bonded strand at the service limit state, to provide t...

  17. Monolithically integrated Si gate-controlled light-emitting device: science and properties

    NASA Astrophysics Data System (ADS)

    Xu, Kaikai

    2018-02-01

    The motivation of this study is to develop a p-n junction based light emitting device, in which the light emission is conventionally realized using reverse current driving, by voltage driving. By introducing an additional terminal of insulated gate for voltage driving, a novel three-terminal Si light emitting device is described where both the light intensity and spatial light pattern of the device are controlled by the gate voltage. The proposed light emitting device employs injection-enhanced Si in avalanche mode where electric field confinement occurs in the corner of a reverse-biased p+n junction. It is found that, depending on the bias conditions, the light intensity is either a linear or a quadratic function of the applied gate voltage or the reverse-bias. Since the light emission is based on the avalanching mode, the Si light emitting device offers the potential for very large scale integration-compatible light emitters for inter- or intra-chip signal transmission and contactless functional testing of wafers.

  18. 21 CFR 868.6250 - Portable air compressor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e.g., to drive ventilators and other respiratory devices. (b) Classification. Class II (performance...

  19. 21 CFR 868.6250 - Portable air compressor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e.g., to drive ventilators and other respiratory devices. (b) Classification. Class II (performance...

  20. Economics and terminal area environmental impact of STOL transportation

    NASA Technical Reports Server (NTRS)

    Stewart, E. C.

    1973-01-01

    The impact of short takeoff and landing aircraft in meeting the needs of short haul transportation systems is analyzed. The objectives of the short haul system are evaluated on the basis of the following criteria: (1) service to the passenger, (2) economic viability, and (3) terminal area environment conditions caused by community noise, ground and air decongestion, and air pollution. Data are presented in the forms of tables, charts, and graphs. An itemization of the conclusions reached after the preliminary investigation is included.

  1. Terminal-area STOL operating systems experiments program

    NASA Technical Reports Server (NTRS)

    Smith, D. W.; Watson, D.; Christensen, J. V.

    1972-01-01

    A system study to determine the application of short takeoff aircraft for a high speed, short haul air transportation service was conducted. The study focused on developing information which will aid in choosing system concepts, design criteria, operating procedures, landing guidance systems, air traffic control systems, and airborne avionics and flight control systems. A terminal area STOL operating system experiments program was developed. The objectives, program approach, program schedule, typical experiments, research facilities to be used, and program status are discussed.

  2. Design and implementation of a telecommunication interface for the TAATM/TCV real-time experiment

    NASA Technical Reports Server (NTRS)

    Nolan, J. D.

    1981-01-01

    The traffic situation display experiment of the terminal configured vehicle (TCV) research program requires a bidirectional data communications tie line between an computer complex. The tie line is used in a real time environment on the CYBER 175 computer by the terminal area air traffic model (TAATM) simulation program. Aircraft position data are processed by TAATM with the resultant output sent to the facility for the generation of air traffic situation displays which are transmitted to a research aircraft.

  3. Conceptual Design of a Tiltrotor Transport Flight Deck

    NASA Technical Reports Server (NTRS)

    Decker, William A.; Dugan, Daniel C.; Simmons, Rickey C.; Tucker, George E.; Aiken, Edwin W. (Technical Monitor)

    1995-01-01

    A tiltrotor transport has considerable potential as a regional transport, increasing the air transportation system capacity by off-loading conventional runways. Such an aircraft will have a flight deck suited to its air transportation task and adapted to unique urban vertiport operating requirements. Such operations are likely to involve steep, slow instrument approaches for vertical and extremely short rolling take-offs and landings. While much of a tiltrotor transport's operations will be in common with commercial fixed-wing operations, terminal area operations will impose alternative flight deck design solutions. Control systems, displays and guidance, and control inceptors must be tailored to both routine and emergency vertical flight operations. This paper will survey recent experience with flight deck design elements suitable to a tiltrotor transport and will propose a conceptual cockpit design for such an aircraft. A series of piloted simulations using the NASA Ames Vertical Motion Simulator have investigated cockpit design elements and operating requirements for tiltrotor transports operating into urban vertiports. These experiments have identified the need for a flight director or equivalent display guidance for steep final approaches. A flight path vector display format has proven successful for guiding tiltrotor transport terminal area operations. Experience with a Head-Up Display points to the need for a bottom-mounted display device to maximize its utility on steep final approach paths. Configuration control (flap setting and nacelle angle) requires appropriate augmentation and tailoring for civil transport operations, flown to an airline transport pilot instrument flight rules (ATP-IFR) standard. The simulation experiments also identified one thrust control lever geometry as inappropriate to the task and found at least acceptable results with the vertical thrust control lever of the XV-15. In addition to the thrust controller, the attitude control of a tiltrotor transport may be effected through an inceptor other than the current center sticks in the XV-15 and V-22. Simulation and flight investigations of side-stick control inceptors for rotorcraft, augmented by a 1985 flight test of a side-stick controller in the XV-15 suggest the potential of such a device in a transport cockpit.

  4. Ka-band MMIC array system for ACTS aeronautical terminal experiment (Aero-X)

    NASA Technical Reports Server (NTRS)

    Raquet, Charles A.; Zakrajsek, Robert J.; Lee, Richard Q.; Andro, Monty; Turtle, John P.

    1995-01-01

    During the summer of 1994, the Advanced Communication Technology Satellite (ACTS) Aeronautical Terminal Experiment (Aero-X) was successfully completed by the NASA Lewis Research Center (LeRC) and the Jet Propulsion Laboratory (JPL). 4.8 and 9.6 Kbps duplex voice links were established between the LeRC Learjet and the ACTS Link Evaluation Terminal (LET) in Cleveland, Ohio, via the ACTS. The antenna system used in this demonstration was developed by LeRC and featured LeRC and US Air Force experimental arrays using GaAs MMIC devices at each radiating element for electronic beam steering and distributed power amplification. The antenna system consisted of three arrays mounted inside the LeRC Learjet, pointing out through the windows. An open loop tracking controller developed by LeRC used information from the aircraft position and attitude sensors to automatically steer the arrays toward ACTS during flight JPL ACTS Mobile Terminal (AMT) system hardware was used as transceivers both on the aircraft and at the LET. The single 32 element MMIC transmit array developed by NASA/LeRC and Texas Instruments has an EIRP of 23.4 dBW at boresight. The two 20 GHz MMIC receive arrays were developed in a cooperative effort with the USAF Rome Laboratory/Electronic System Center, taking advantage of existing USAF array development contracts with Boeing and Martin Marietta. The Boeing array has 23 elements and a G/T of 16/6 db/degK at boresight. The Martin Marietta array has 16 elements and a G/T of 16.1 db/degK at boresight. The three proof-of-concept arrays, the array control system and their integration and operation in the Learjet for Aero-X are described.

  5. Impact of an ultraviolet air sterilizer on cardiac surgery patients, a randomized clinical trial.

    PubMed

    Heredia-Rodríguez, María; Álvarez-Fuente, Elisa; Bustamante-Munguira, Juan; Poves-Alvarez, Rodrigo; Fierro, Inmaculada; Gómez-Sánchez, Esther; Gómez-Pesquera, Estefanía; Lorenzo-López, Mario; Eiros, José María; Álvarez, Francisco Javier; Tamayo, Eduardo

    2018-05-25

    Numerous studies have evaluated the use of ultraviolet-C devices for terminal disinfection in hospitals, however, to date there is little information about the device's final impact on patients. We investigated the effect of an ultraviolet air sterilizer (UVAS) on the clinical outcomes of cardiac surgery patients. This random, prospective and non-interventional study included 1097 adult patients undergoing elective cardiac surgery: 522 stayed in an ICU room with UVAS (Medixair ® ) and 575 patients ICU room without UVAS and were used as a control. The primary outcome measure was to evaluate the effect of a UVAS on the overall prevalence of nosocomial infections in postoperative cardiac patients in ICUs. No significant differences in ventilator-associated pneumonia (4.6% vs. 5.0%, p=0.77) and total infection (14.0% vs. 15.5%, p=0.45) rates were detected in patients with and without the UVAS. The length of stay in the intensive care unit and at the hospital was similar in both groups, UVAS (4.6 (8.2) days and 18.3 (5.5) days) and without UVAS (4.6 (7.3) days and 19.2 (18.6) days). The 30-day in-hospital mortality rate was 5.3%, no significant differences between groups were observed (p=0.053). Novel ultraviolet-C technology has not been shown to significantly reduce nosocomial infections or mortality rates in cardiac surgery patients. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  6. 21 CFR 880.6500 - Medical ultraviolet air purifier.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical ultraviolet air purifier. 880.6500 Section... Miscellaneous Devices § 880.6500 Medical ultraviolet air purifier. (a) Identification. A medical ultraviolet air purifier is a device intended for medical purposes that is used to destroy bacteria in the air by exposure...

  7. 21 CFR 880.6500 - Medical ultraviolet air purifier.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical ultraviolet air purifier. 880.6500 Section... Miscellaneous Devices § 880.6500 Medical ultraviolet air purifier. (a) Identification. A medical ultraviolet air purifier is a device intended for medical purposes that is used to destroy bacteria in the air by exposure...

  8. 21 CFR 880.6500 - Medical ultraviolet air purifier.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical ultraviolet air purifier. 880.6500 Section... Miscellaneous Devices § 880.6500 Medical ultraviolet air purifier. (a) Identification. A medical ultraviolet air purifier is a device intended for medical purposes that is used to destroy bacteria in the air by exposure...

  9. Truck Terminal and Warehouse Survey Results

    DOT National Transportation Integrated Search

    1996-03-01

    The survey of truck terminals and warehouses resulted in locating the highway bottlenecks for truck movements which are more localized in nature than the previous air, marine, and rail surveys performed by the NYMTC Central Staff. However, all of the...

  10. The Human Factors of FMS Usage in the Terminal Area

    DOT National Transportation Integrated Search

    1997-08-01

    The development of advanced automation for arrival aircraft into the terminal : area is being investigated for both the air traffic control (ATC) and airborne : environments. For the automation to be effective and provide the best advisory : informat...

  11. Air Traffic Control: Status of FAA's Standard Terminal Automation Replacement System Project

    DOT National Transportation Integrated Search

    1997-03-01

    Since the early 1980s, FAA's modernization efforts have experienced lengthy : schedule delays and substantial cost overruns. Because of such problems, in : 1994, FAA restructured its acquisition of the Terminal Advanced Automation : System into more ...

  12. Meeting Air Training Command’s Future Airspace Needs.

    DTIC Science & Technology

    1982-08-01

    Fekke Lieutenant Colonel, USAF I!. ..... .... .a T B DTIG 3Air University (ATC) Air War College -j Maxwell Air Force Base, Alabama ,9 83 11 03 04...Commandant, Air War College, Maxwell Air Force Base, Alabama. It has been cleared for public release. -ii BIOGRAPHICAL SKETCH Upon entering the Air...efficiently provide the type of terminal support required by ATC. viii 0%.- KINTRODUCTION This monograph documents a long-range planning effort which exam

  13. Spin Seebeck Effect and Thermal Colossal Magnetoresistance in Graphene Nanoribbon Heterojunction

    PubMed Central

    Ni, Yun; Yao, Kailun; Fu, Huahua; Gao, Guoying; Zhu, Sicong; Wang, Shuling

    2013-01-01

    Spin caloritronics devices are very important for future development of low-power-consumption technology. We propose a new spin caloritronics device based on zigzag graphene nanoribbon (ZGNR), which is a heterojunction consisting of single-hydrogen-terminated ZGNR (ZGNR-H) and double-hydrogen-terminated ZGNR (ZGNR-H2). We predict that spin-up and spin-down currents flowing in opposite directions can be induced by temperature difference instead of external electrical bias. The thermal spin-up current is considerably large and greatly improved compared with previous work in graphene. Moreover, the thermal colossal magnetoresistance is obtained in our research, which could be used to fabricate highly-efficient spin caloritronics MR devices. PMID:23459307

  14. Programmable electroacoustic filter apparatus and method for its manufacture

    DOEpatents

    Nordquist, Christopher; Olsson, Roy H.; Scott, Sean Michael; Wojciechowski, Kenneth; Branch, Darren W.

    2016-03-01

    An acoustically coupled frequency selective radio frequency (RF) device is provided. The device includes a piezoelectric substrate overlain by a plurality of electrodes. The device further includes a pair of RF input terminals at least one of which is electrically connected to at least one of the electrodes, and a pair of output RF terminals, at least one of which is electrically connected to at least one other of the electrodes. At least one of the electrodes is electromechanically reconfigurable between a state in which it is closer to a face of the piezoelectric substrate and at least one state in which it is farther from the face of the piezoelectric substrate.

  15. Design of Secure and Lightweight Authentication Protocol for Wearable Devices Environment.

    PubMed

    Das, Ashok Kumar; Wazid, Mohammad; Kumar, Neeraj; Khan, Muhammad Khurram; Choo, Kim-Kwang Raymond; Park, YoungHo

    2017-09-18

    Wearable devices are used in various applications to collect information including step information, sleeping cycles, workout statistics, and health related information. Due to the nature and richness of the data collected by such devices, it is important to ensure the security of the collected data. This paper presents a new lightweight authentication scheme suitable for wearable device deployment. The scheme allows a user to mutually authenticate his/her wearable device(s) and the mobile terminal (e.g., Android and iOS device) and establish a session key among these devices (worn and carried by the same user) for secure communication between the wearable device and the mobile terminal. The security of the proposed scheme is then demonstrated through the broadly-accepted Real-Or-Random model, as well as using the popular formal security verification tool, known as the Automated Validation of Internet Security Protocols and Applications (AVISPA). Finally, we present a comparative summary of the proposed scheme in terms of the overheads such as computation and communication costs, security and functionality features of the proposed scheme and related schemes, and also the evaluation findings from the NS2 simulation.

  16. Real-time interactive simulation: using touch panels, graphics tablets, and video-terminal keyboards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venhuizen, J.R.

    1983-01-01

    A Simulation Laboratory utilizing only digital computers for interactive computing must rely on CRT based graphics devices for output devices, and keyboards, graphics tablets, and touch panels, etc., for input devices. The devices all work well, with the combination of a CRT with a touch panel mounted on it as the most flexible combination of input/output devices for interactive simulation.

  17. 78 FR 15682 - Notification of Proposed Production Activity TTI, Inc.; Subzone 196A (Electromechanical and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-12

    ... Activity TTI, Inc.; Subzone 196A (Electromechanical and Circuit Protection Devices Production/ Kitting... electromechanical and circuit protection device production/kitting for a variety of commercial, aerospace and... for crimping, insertion/extraction, and terminal removal, and electromechanical devices (duty rates...

  18. 77 FR 13343 - Pilot Program for Early Feasibility Study Investigational Device Exemption Applications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-06

    ...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications; Termination of... acceptance of nominations for the Early Feasibility Study Investigational Device Exemption (IDE) Applications... technologies to participate in a pilot program for early feasibility study IDE applications. FDA is also...

  19. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  20. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  1. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  2. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  3. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  4. 78 FR 23593 - Certain Mobile Electronic Devices Incorporating Haptics; Termination of Investigation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-19

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-834] Certain Mobile Electronic Devices... this investigation may be viewed on the Commission's electronic docket (EDIS) at http://edis.usitc.gov... mobile electronic devices incorporating haptics that infringe certain claims of six Immersion patents. 77...

  5. Filter line wiring designs in aircraft

    NASA Astrophysics Data System (ADS)

    Rowe, Richard M.

    1990-10-01

    The paper presents a harness design using a filter-line wire technology and appropriate termination methods to help meet high-energy radiated electromagnetic field (HERF) requirements for protection against the adverse effects of EMI on electrical and avionic systems. Filter-line interconnect harnessing systems discussed consist of high-performance wires and cables; when properly wired they suppress conducted and radiated EMI above 100 MHz. Filter-line termination devices include backshell adapters, braid splicers, and shield terminators providing 360-degree low-impedance terminations and enhancing maintainability of the system.

  6. [Hygienic relevance of devices for indoor air treatment].

    PubMed

    Wegner, J

    1982-01-01

    Shortcomings regarding design, construction, operation (including emissions), maintenance/repair and control of buildings with rooms for the accommodation of persons may be the reason to install air conditioning devices. According to manufacturers' data, such devices may be applied for various purposes, e.g. the creation of a defined air temperature or humidity, an increase of the supply of outdoor air, the cleaning and deodorization of indoor air or the alteration of the so-called electric climate of a room. The hygienic health evaluation of the different types of air conditioning devices should establish whether --there are aspects of health necessitating alterations of the microclimate of a room; --such alterations could be brought about in a more economic way by purely constructional or individual measures; --the function of individual apparatuses could be accomplished in a better way by replacing them by a larger device serving several rooms; --the operation of such devices may produce adverse health effects such as nuisance by noise, formation of undesirable gases (ozone), danger owing to non-adherence to electric safety rules; --there will be no damage to rooms and furniture, e.g. by water droplets. A look at a number of commercially available devices shows that they are generally dispensable. There are, however, special rare cases where the use of such devices may result in an improvement of the quality of indoor environments.

  7. Transplantation of macroencapsulated human islets within the bioartificial pancreas βAir to patients with type 1 diabetes mellitus.

    PubMed

    Carlsson, Per-Ola; Espes, Daniel; Sedigh, Amir; Rotem, Avi; Zimerman, Baruch; Grinberg, Helena; Goldman, Tali; Barkai, Uriel; Avni, Yuval; Westermark, Gunilla T; Carlbom, Lina; Ahlström, Håkan; Eriksson, Olof; Olerud, Johan; Korsgren, Olle

    2017-12-29

    Macroencapsulation devices provide the dual possibility of immunoprotecting transplanted cells while also being retrievable, the latter bearing importance for safety in future trials with stem cell-derived cells. However, macroencapsulation entails a problem with oxygen supply to the encapsulated cells. The βAir device solves this with an incorporated refillable oxygen tank. This phase 1 study evaluated the safety and efficacy of implanting the βAir device containing allogeneic human pancreatic islets into patients with type 1 diabetes. Four patients were transplanted with 1-2 βAir devices, each containing 155 000-180 000 islet equivalents (ie, 1800-4600 islet equivalents per kg body weight), and monitored for 3-6 months, followed by the recovery of devices. Implantation of the βAir device was safe and successfully prevented immunization and rejection of the transplanted tissue. However, although beta cells survived in the device, only minute levels of circulating C-peptide were observed with no impact on metabolic control. Fibrotic tissue with immune cells was formed in capsule surroundings. Recovered devices displayed a blunted glucose-stimulated insulin response, and amyloid formation in the endocrine tissue. We conclude that the βAir device is safe and can support survival of allogeneic islets for several months, although the function of the transplanted cells was limited (Clinicaltrials.gov: NCT02064309). © 2018 The Authors. American Journal of Transplantation published by Wiley Periodicals, Inc. on behalf of The American Society of Transplantation and the American Society of Transplant Surgeons.

  8. A Concept for Robust, High Density Terminal Air Traffic Operations

    NASA Technical Reports Server (NTRS)

    Isaacson, Douglas R.; Robinson, John E.; Swenson, Harry N.; Denery, Dallas G.

    2010-01-01

    This paper describes a concept for future high-density, terminal air traffic operations that has been developed by interpreting the Joint Planning and Development Office s vision for the Next Generation (NextGen) Air Transportation System and coupling it with emergent NASA and other technologies and procedures during the NextGen timeframe. The concept described in this paper includes five core capabilities: 1) Extended Terminal Area Routing, 2) Precision Scheduling Along Routes, 3) Merging and Spacing, 4) Tactical Separation, and 5) Off-Nominal Recovery. Gradual changes are introduced to the National Airspace System (NAS) by phased enhancements to the core capabilities in the form of increased levels of automation and decision support as well as targeted task delegation. NASA will be evaluating these conceptual technological enhancements in a series of human-in-the-loop simulations and will accelerate development of the most promising capabilities in cooperation with the FAA through the Efficient Flows Into Congested Airspace Research Transition Team.

  9. Nanogap Electrodes towards Solid State Single-Molecule Transistors.

    PubMed

    Cui, Ajuan; Dong, Huanli; Hu, Wenping

    2015-12-01

    With the establishment of complementary metal-oxide-semiconductor (CMOS)-based integrated circuit technology, it has become more difficult to follow Moore's law to further downscale the size of electronic components. Devices based on various nanostructures were constructed to continue the trend in the minimization of electronics, and molecular devices are among the most promising candidates. Compared with other candidates, molecular devices show unique superiorities, and intensive studies on molecular devices have been carried out both experimentally and theoretically at the present time. Compared to two-terminal molecular devices, three-terminal devices, namely single-molecule transistors, show unique advantages both in fundamental research and application and are considered to be an essential part of integrated circuits based on molecular devices. However, it is very difficult to construct them using the traditional microfabrication techniques directly, thus new fabrication strategies are developed. This review aims to provide an exclusive way of manufacturing solid state gated nanogap electrodes, the foundation of constructing transistors of single or a few molecules. Such single-molecule transistors have the potential to be used to build integrated circuits. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Second Line of Defense, Port of Buenos Aires and Exolgan Container Terminal Operational Testing and Evaluation Plan, Buenos Aires, Argentina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, Bryan W.

    2012-08-23

    The Office of the Second Line of Defense (SLD) Megaports project team for Argentina will conduct operational testing and evaluation (OT&E) at Exolgan Container Terminal at the Port of Dock Sud from July 16-20, 2012; and at the Port of Buenos Aires from September 3-7, 2012. SLD is installing radiation detection equipment to screen export, import, and transshipment containers at these locations. The purpose of OT&E is to validate and baseline an operable system that meets the SLD mission and to ensure the system continues to perform as expected in an operational environment with Argentina Customs effectively adjudicating alarms.

  11. Electrolyte-gated transistors based on conducting polymer nanowire junction arrays.

    PubMed

    Alam, Maksudul M; Wang, Jun; Guo, Yaoyao; Lee, Stephanie P; Tseng, Hsian-Rong

    2005-07-07

    In this study, we describe the electrolyte gating and doping effects of transistors based on conducting polymer nanowire electrode junction arrays in buffered aqueous media. Conducting polymer nanowires including polyaniline, polypyrrole, and poly(ethylenedioxythiophene) were investigated. In the presence of a positive gate bias, the device exhibits a large on/off current ratio of 978 for polyaniline nanowire-based transistors; these values vary according to the acidity of the gate medium. We attribute these efficient electrolyte gating and doping effects to the electrochemically fabricated nanostructures of conducting polymer nanowires. This study demonstrates that two-terminal devices can be easily converted into three-terminal transistors by simply immersing the device into an electrolyte solution along with a gate electrode. Here, the field-induced modulation can be applied for signal amplification to enhance the device performance.

  12. Photographic copy of reproduced photograph dated 1942. Exterior view, west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of reproduced photograph dated 1942. Exterior view, west elevation. Building camouflaged during World War II. - Grand Central Air Terminal, 1310 Air Way, Glendale, Los Angeles County, CA

  13. 10 CFR 431.95 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.95 Materials... Packaged Terminal Air-Conditioners and Heat Pumps,” published September 2004 (AHRI 310/380-2004), IBR... Single Package Vertical Air-Conditioners and Heat Pumps,” dated 2003, (AHRI 390-2003), IBR approved for...

  14. 10 CFR 431.95 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.95 Materials... Packaged Terminal Air-Conditioners and Heat Pumps,” published September 2004 (AHRI 310/380-2004), IBR... Single Package Vertical Air-Conditioners and Heat Pumps,” dated 2003, (AHRI 390-2003), IBR approved for...

  15. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...

  16. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...

  17. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...

  18. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...

  19. 40 CFR 60.4895 - By what date must I conduct annual air pollution control device inspections and make any...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pollution control device inspections and make any necessary repairs? 60.4895 Section 60.4895 Protection of... Compliance Requirements § 60.4895 By what date must I conduct annual air pollution control device inspections and make any necessary repairs? (a) You must conduct an annual inspection of each air pollution...

  20. Development of a Low-Cost, Stand-Alone Microterminal for Support of Testing and Instruction. Final Report for Period January 1977-February 1978.

    ERIC Educational Resources Information Center

    Steffen, Dale A.; And Others

    A study was undertaken to develop a microterminal for use in a computer-based instructional system. Objectives were to use new microprocessor technology to produce one terminal that is more effective and efficient than either the management terminal or the plasma type interactive terminal presently in use by the Air Force Advanced Instructional…

  1. ARCHITECTURAL DRAWING, MILITARY AIR COMMAND COMMUNICATION CENTER PRECAST CONCRETE WALL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ARCHITECTURAL DRAWING, MILITARY AIR COMMAND COMMUNICATION CENTER PRECAST CONCRETE WALL DETAILS. DATED 03/15/1971 - Wake Island Airfield, Terminal Building, West Side of Wake Avenue, Wake Island, Wake Island, UM

  2. Recent technical advances in general purpose mobile Satcom aviation terminals

    NASA Technical Reports Server (NTRS)

    Sydor, John T.

    1990-01-01

    A second general aviation amplitude companded single sideband (ACSSB) aeronautical terminal was developed for use with the Ontario Air Ambulance Service (OAAS). This terminal is designed to have automatic call set up and take down and to interface with the Public Service Telephone Network (PSTN) through a ground earth station hub controller. The terminal has integrated RF and microprocessor hardware which allows such functions as beam steering and automatic frequency control to be software controlled. The terminal uses a conformal patch array system to provide almost full azimuthal coverage. Antenna beam steering is executed without relying on aircraft supplied orientation information.

  3. Photonic crystal fiber in-line Mach-Zehnder interferometer for explosive detection.

    PubMed

    Tao, Chuanyi; Wei, Heming; Feng, Wenlin

    2016-02-08

    We report a photonic crystal fiber (PCF) in-line Mach-Zehnder interferometer used as a gas sensor device which exhibits high sensitivity to the explosive trinitrotoluene (TNT). The interferometric sensor head is formed by embedding a segment of large-mode-area/grapefruit PCF between standard single-mode fibers via butt coupling, which produces two small air gaps in between terminated fiber ends with ceramic ferrule connectors as coupling regions, which also serve as inlet/outlet for the gas. The spectral response of the interferometer is investigated in terms of its wavelength spectrum. The selectivity to TNT vapor is achieved by immobilizing a molecular recognition ployallylamine layer on the inner surface of the holey region of the PCF. The TNT-induced variations of the interference fringes are measured and the sensing capability of the proposed sensor is demonstrated experimentally.

  4. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  5. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  6. 40 CFR 610.21 - Device functional category and vehicle system effects.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... device's category will be based on: (1) Engineering principles governing operation of the device; (2... mechanical) All. Vapor Injectors All. Choke controls 1, 2, and 4. Air filters 1, 2, and 4. Fuel-air...

  7. High-sensitivity two-terminal magnetoresistance devices using InGaAs/AlGaAs two-dimensional channel on GaAs substrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Di-Cheng; Pan, You-Wei; Lin, Shih-Wei

    2016-04-25

    We demonstrate experimentally the two-terminal magnetic sensors exhibiting an extraordinary magneto-resistance effect by using an InGaAs quantum well channel with a metal-shunting structure. A high magneto-resistance of 17.3% and a sensitivity of 488.1 Ω/T have been obtained at 1 T and room temperature with our geometrical design. The two-contact configuration and the high-mobility electron transistor-compatible epitaxy structure make the devices promising for high-sensitivity magnetic sensing integration and applications.

  8. Spin-polarized transport in multiterminal silicene nanodevices

    NASA Astrophysics Data System (ADS)

    Xu, Ning

    2018-01-01

    The spin-polarized transport properties of multiterminal silicene nanodevices are studied using the tight binding model and Landauer-Buttier approach. We propose a four-terminal †-shaped junction device and two types of three-terminal T-shaped junction devices, which are made of the crossing of a zigzag and an armchair silicene nanoribbon. If the electrons are injected into the metallic lead, the near-perfect spin polarization with 100% around the Fermi energy can be achieved easily at the other semiconducting leads. Thus the multiterminal silicene nanodevices can act as controllable spin filters.

  9. Charge Carrier Transport Mechanism Based on Stable Low Voltage Organic Bistable Memory Device.

    PubMed

    Ramana, V V; Moodley, M K; Kumar, A B V Kiran; Kannan, V

    2015-05-01

    A solution processed two terminal organic bistable memory device was fabricated utilizing films of polymethyl methacrylate PMMA/ZnO/PMMA on top of ITO coated glass. Electrical characterization of the device structure showed that the two terminal device exhibited favorable switching characteristics with an ON/OFF ratio greater than 1 x 10(4) when the voltage was swept between - 2 V and +3 V. The device maintained its state after removal of the bias voltage. The device did not show degradation after a 1-h retention test at 120 degrees C. The memory functionality was consistent even after fifty cycles of operation. The charge transport switching mechanism is discussed on the basis of carrier transport mechanism and our analysis of the data shows that the charge carrier trans- port mechanism of the device during the writing process can be explained by thermionic emission (TE) and space-charge-limited-current (SCLC) mechanism models while erasing process could be explained by the FN tunneling mechanism. This demonstration provides a class of memory devices with the potential for low-cost, low-power consumption applications, such as a digital memory cell.

  10. 10 CFR 431.95 - Materials incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.95 Materials...) published in 2004, “Standard for Packaged Terminal Air-Conditioners and Heat Pumps,” IBR approved for § 431... for Commercial Air Conditioners and Heat Pumps,” Docket No. EE-RM/TP-99-460, 1000 Independence Avenue...

  11. 10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... seasonal energy efficiency ratio (SEER in British thermal units per Watt-hour (Btu/Wh)), the heating...) Package terminal air conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour... package vertical air conditioner: The energy efficiency ratio (EER in British thermal units per Watt-hour...

  12. 10 CFR 429.43 - Commercial heating, ventilating, air conditioning (HVAC) equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... seasonal energy efficiency ratio (SEER in British thermal units per Watt-hour (Btu/Wh)), the heating...) Package terminal air conditioners: The energy efficiency ratio (EER in British thermal units per Watt-hour... package vertical air conditioner: The energy efficiency ratio (EER in British thermal units per Watt-hour...

  13. Problems in air traffic management. V., Identification and potential aptitude test measures for selection of tower air traffic controller trainees.

    DOT National Transportation Integrated Search

    1965-07-01

    A study of over 200 Terminal Air Traffic Control Specialists indicated that their training performance could be well predicted by a composite of four aptitude tests measuring: numerical ability, non-verbal abstract reasoning, ability to solve simplif...

  14. Problems in air traffic management. VI., Interaction of training-entry age with intellectual and personality characteristics of air traffic control specialists.

    DOT National Transportation Integrated Search

    1965-07-01

    Over 900 Enroute and Terminal Air Traffic Controller Specialist (ATCS) trainees were administered a large number of aptitude and personality tests. Examination of the relationships between the performance scores and age at entry into training reveale...

  15. 14 CFR 136.41 - Interim operating authority.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND NATIONAL PARKS AIR TOUR MANAGEMENT National Parks Air Tour Management § 136.41 Interim operating... terminate 180 days after the date on which an air tour management plan is established for the park and tribal lands; (6) Shall promote protection of national park resources, visitor experiences, and tribal...

  16. 14 CFR 93.51 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area § 93.51... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Applicability. 93.51 Section 93.51..., Terminal Area. [Doc. No. FAA-2002-13235, 68 FR 9795, Feb. 28, 2003] ...

  17. 14 CFR 93.51 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area § 93.51... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Applicability. 93.51 Section 93.51..., Terminal Area. [Doc. No. FAA-2002-13235, 68 FR 9795, Feb. 28, 2003] ...

  18. 14 CFR 93.51 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area § 93.51... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Applicability. 93.51 Section 93.51..., Terminal Area. [Doc. No. FAA-2002-13235, 68 FR 9795, Feb. 28, 2003] ...

  19. 14 CFR 93.51 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area § 93.51... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Applicability. 93.51 Section 93.51..., Terminal Area. [Doc. No. FAA-2002-13235, 68 FR 9795, Feb. 28, 2003] ...

  20. 14 CFR 93.51 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area § 93.51... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Applicability. 93.51 Section 93.51..., Terminal Area. [Doc. No. FAA-2002-13235, 68 FR 9795, Feb. 28, 2003] ...

  1. 16 CFR 1211.10 - Requirements for all entrapment protection devices.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... adjacent terminal. (c) Splash test. (1) An external entrapment protection device intended to be installed... such a manner most likely to cause water to splash the enclosure of electric components. However, the...

  2. 16 CFR 1211.10 - Requirements for all entrapment protection devices.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... adjacent terminal. (c) Splash test. (1) An external entrapment protection device intended to be installed... such a manner most likely to cause water to splash the enclosure of electric components. However, the...

  3. 16 CFR 1211.10 - Requirements for all entrapment protection devices.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... adjacent terminal. (c) Splash test. (1) An external entrapment protection device intended to be installed... such a manner most likely to cause water to splash the enclosure of electric components. However, the...

  4. 16 CFR § 1211.10 - Requirements for all entrapment protection devices.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... adjacent terminal. (c) Splash test. (1) An external entrapment protection device intended to be installed... such a manner most likely to cause water to splash the enclosure of electric components. However, the...

  5. Microbiological evaluation of a newly designed dental air-turbine handpiece for anti-cross contaminations.

    PubMed

    Ohsuka, S; Ohta, M; Masuda, K; Kaneda, T; Ueda, M

    1994-01-01

    The effectiveness of a newly developed anti-cross contamination device for a dental air-turbine handpiece was tested. The handpiece with or without the anti-cross contamination device was contaminated with two bacterial strains, Staphylococcus aureus and Streptococcus mutans, as well as two bacteriophage strains, T2 and MS2. After contamination with these microorganisms, the handpieces were disinfected with glutaraldehyde or replaced with newly autoclaved ones. Residual microorganisms inside the handpiece or an air/water supply hose line were collected and counted after overnight cultivation. The anti-cross contamination device effectively reduced the contamination level of an air-turbine handpiece to that of the negative control. No microbial contamination in the air/water supply hose line was detected with this device.

  6. Flow visualization of a non-contact transport device by Coanda effect

    NASA Astrophysics Data System (ADS)

    Iki, Norihiko; Abe, Hiroyuki; Okada, Takashi

    2014-08-01

    AIST proposes new technology of non-contact transport device utilizing Coanda effect. A proposed non-contact transport device has a cylindrical body and circular slit for air. The air flow around non-contact device is turbulent and its flow pattern depends on the injection condition. Therefore we tried visualization of the air flow around non -contact device as the first step of PIV measurement. Several tracer particles were tried such as TiO2 particles, water droplets, potatoes starch, rice starch, corn starch. Hot-wire anemometer is employed to velocity measurement. TiO2 particles deposit inside of a slit and clogging of a slit occurs frequently. Potato starch particles do not clog a slit but they are too heavy to trace slow flow area. Water droplets by ultrasonic atomization also deposit inside of slit but they are useful to visualize flow pattern around a non-contact transport device by being supplied from circumference. Coanda effect of proposed non-contact transport device was confirmed and injected air flow pattern switches by a work. Air flow around non-contact trance port device is turbulent and its velocity range is wide. Therefore flow measurement by tracer part icle has traceability issue. Suitable tracer and exposure condition depends on target area.

  7. Fluid sampling device

    NASA Technical Reports Server (NTRS)

    Studenick, D. K. (Inventor)

    1977-01-01

    An inlet leak is described for sampling gases, more specifically, for selectively sampling multiple fluids. This fluid sampling device includes a support frame. A plurality of fluid inlet devices extend through the support frame and each of the fluid inlet devices include a longitudinal aperture. An opening device that is responsive to a control signal selectively opens the aperture to allow fluid passage. A closing device that is responsive to another control signal selectively closes the aperture for terminating further fluid flow.

  8. Impact of atmospheric particulate matter pollutants to IAQ of airport terminal buildings: A first field study at Tianjin Airport, China

    NASA Astrophysics Data System (ADS)

    Ren, Jianlin; Cao, Xiaodong; Liu, Junjie

    2018-04-01

    Passengers usually spend hours in the airport terminal buildings waiting for their departure. During the long waiting period, ambient fine particles (PM2.5) and ultrafine particles (UFP) generated by airliners may penetrate into terminal buildings through open doors and the HVAC system. However, limited data are available on passenger exposure to particulate pollutants in terminal buildings. We conducted on-site measurements on PM2.5 and UFP concentration and the particle size distribution in the terminal building of Tianjin Airport, China during three different seasons. The results showed that the PM2.5 concentrations in the terminal building were considerably larger than the values guided by Chinese standard and WHO on all of the tested seasons, and the conditions were significantly affected by the outdoor air (Spearman test, p < 0.01). The indoor/outdoor PM2.5 ratios (I/O) ranged from 0.67 to 0.84 in the arrival hall and 0.79 to 0.96 in the departure hall. The particle number concentration in the terminal building presented a bi-modal size distribution, with one mode being at 30 nm and another mode at 100 nm. These results were totally different from the size distribution measured in a normal urban environment. The total UFP exposure during the whole waiting period (including in the terminal building and airliner cabin) of a passenger is approximately equivalent to 11 h of exposure to normal urban environments. This study is expected to contribute to the improvement of indoor air quality and health of passengers in airport terminal buildings.

  9. Reducing the beam impedance of the kicker at the 3-GeV rapid cycling synchrotron of the Japan Proton Accelerator Research Complex

    NASA Astrophysics Data System (ADS)

    Shobuda, Yoshihiro; Chin, Yong Ho; Hayashi, Naoki; Irie, Yoshiro; Takayanagi, Tomohiro; Togashi, Tomohito; Toyama, Takeshi; Yamamoto, Kazami; Yamamoto, Masanobu

    2018-06-01

    The present four-terminal kicker at the rapid cycling synchrotron (RCS) at the Japan Proton Accelerator Research Complex has the power-saving benefit that it allows beam extraction by doubling the excitation currents with two shorted ends. In this configuration, two terminals of the kicker are connected to the pulse-forming line while the other two are terminated in a short circuit. On the other hand, beam instabilities are excited in the RCS by the kicker beam impedances, which result from the short-circuit termination of the kicker. In this paper, we describe a scheme to reduce the beam impedance of the kicker using diodes (nonlinear devices), while retaining the benefit of the doubled kicker excitation currents. We employ a simulation technique to determine the beam impedance of the kicker, even when such nonlinear devices and long cables are included. The characteristic of beam impedance measured using the accelerated beams is well explained by that obtained from the simulation.

  10. Dual-channel current valve in a three terminal zigzag graphene nanoribbon junction

    NASA Astrophysics Data System (ADS)

    Zhang, L.

    2017-02-01

    We theoretically propose a dual-channel current valve based on a three terminal zigzag graphene nanoribbon (ZGNR) junction driven by three asymmetric time-dependent pumping potentials. By means of the Keldysh Green’s function method, we show that two asymmetric charge currents can be pumped in the different left-right terminals of the device at a zero bias, which mainly stems from the single photon-assisted pumping approximation and the valley valve effect in a ZGNR p-n junction. The ON and OFF states of pumped charge currents are crucially dependent on the even-odd chain widths of the three electrodes, the pumping frequency, the lattice potential and the Fermi level. Two-tunneling spin valves are also considered to spatially separate and detect 100% polarized spin currents owing to the combined spin pump effect and the valley selective transport in a three terminal ZGNR ferromagnetic junction. Our investigations might be helpful to control the spatial and spin degrees of freedom of electrons in graphene pumping devices.

  11. 40 CFR 65.146 - Nonflare control devices used for equipment leaks only.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.146 Nonflare control devices used for equipment leaks only...

  12. 76 FR 34845 - Medical Devices; Ear, Nose, and Throat Devices; Classification of the Wireless Air-Conduction...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-15

    ... control by other users with a similar medical device. Exposure to non-ionizing radiation Wireless... Administration (FDA) is classifying the wireless air-conduction hearing aid into class II (special controls). The Agency is classifying the device into class II (special controls) in order to provide a reasonable...

  13. Smart Cards and remote entrusting

    NASA Astrophysics Data System (ADS)

    Aussel, Jean-Daniel; D'Annoville, Jerome; Castillo, Laurent; Durand, Stephane; Fabre, Thierry; Lu, Karen; Ali, Asad

    Smart cards are widely used to provide security in end-to-end communication involving servers and a variety of terminals, including mobile handsets or payment terminals. Sometime, end-to-end server to smart card security is not applicable, and smart cards must communicate directly with an application executing on a terminal, like a personal computer, without communicating with a server. In this case, the smart card must somehow trust the terminal application before performing some secure operation it was designed for. This paper presents a novel method to remotely trust a terminal application from the smart card. For terminals such as personal computers, this method is based on an advanced secure device connected through the USB and consisting of a smart card bundled with flash memory. This device, or USB dongle, can be used in the context of remote untrusting to secure portable applications conveyed in the dongle flash memory. White-box cryptography is used to set the secure channel and a mechanism based on thumbprint is described to provide external authentication when session keys need to be renewed. Although not as secure as end-to-end server to smart card security, remote entrusting with smart cards is easy to deploy for mass-market applications and can provide a reasonable level of security.

  14. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  15. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  16. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  17. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  18. 40 CFR 424.40 - Applicability; description of the covered calcium carbide furnaces with wet air pollution control...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... covered calcium carbide furnaces with wet air pollution control devices subcategory. 424.40 Section 424.40... FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Calcium Carbide Furnaces With Wet Air Pollution... with wet air pollution control devices subcategory. The provisions of this subpart are applicable to...

  19. Beale Air Force Base, Perimeter Acquisition Vehicle Entry PhasedArray Warning ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, Satellite Communications Terminal, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  20. Stress in air traffic controllers : effects of ARTS-III

    DOT National Transportation Integrated Search

    1976-11-01

    Physiological, biochemical, and psychological assessments of stress in air traffic controllers were made at Los Angeles (LAX) and Oakland (OAK) Terminal Radar Approach Control (TRACON) facilities before and after installation of Automated Radar Termi...

  1. Data-linked pilot reply time on controller workload and communication in a simulated terminal option

    DOT National Transportation Integrated Search

    2001-05-01

    This report describes an analysis of air traffic control communication and workload in a simulated terminal radar approach : control environment. The objective of this study was to investigate how pilot-to-controller data-link acknowledgment time : m...

  2. Enhanced Terminal Information Services (ETIS) Utilizing the Discrete Address Beacon System (DABS) Data Link - Concept Description

    DOT National Transportation Integrated Search

    1979-07-01

    This report describes a concept for providing enhanced terminal information services (ETIS) to aircraft utilizing the ground-air-ground data link capability of the Discrete Address Beacon System (DABS). ETIS is envisioned as an eventual replacement f...

  3. Satellite Communications for Aeronautics Applications: Technology Development and Demonstration

    NASA Technical Reports Server (NTRS)

    Kerczewski, Robert J.; Hoder, Douglas J.; Zakrajsek, Robert J.

    2001-01-01

    The National Aeronautics and Space Administration (NASA) is performing research and development to improve the safety and increase the capacity of the National Airspace System (NAS). Improved communications, especially to and from the aircraft flight deck, has been identified as an essential enabling technology for future improvements to the air traffic management system and aviation safety. NASA's Glenn Research Center is engaged in research and development of satellite communications technologies for aeronautical applications. A mobile aero terminal has been developed for use with Ku band commercial communications satellites. This experimental terminal will be used in mobile ground and air-based tests and demonstrations during 2000-2004. This paper will describe the basic operational parameters of the Ku Band aero terminal, the communications architecture it is intended to demonstrate, and the key technology issues being addressed in the tests and demonstrations. The design of the Ku Band aero terminal and associated ground testbed, planned tests and demonstrations, and results to date will be presented.

  4. Extensive air showers, lightning, and thunderstorm ground enhancements

    NASA Astrophysics Data System (ADS)

    Chilingarian, A.; Hovsepyan, G.; Kozliner, L.

    2016-09-01

    For lightning research, we monitor particle fluxes from thunderclouds, the so-called thunderstorm ground enhancements (TGEs) initiated by runaway electrons, and extensive air showers (EASs) originating from high-energy protons or fully stripped nuclei that enter the Earth's atmosphere. We also monitor the near-surface electric field and atmospheric discharges using a network of electric field mills. The Aragats "electron accelerator" produced several TGEs and lightning events in the spring of 2015. Using 1-s time series, we investigated the relationship between lightning and particle fluxes. Lightning flashes often terminated the particle flux; in particular, during some TGEs, lightning events would terminate the particle flux thrice after successive recovery. It was postulated that a lightning terminates a particle flux mostly in the beginning of a TGE or in its decay phase; however, we observed two events (19 October 2013 and 20 April 2015) when the huge particle flux was terminated just at the peak of its development. We discuss the possibility of a huge EAS facilitating lightning leader to find its path to the ground.

  5. Traffic Control Device Evaluation Program : FY 2017

    DOT National Transportation Integrated Search

    2018-03-01

    This report presents findings on the activities conducted in the Traffic Control Device Evaluation Program during the 2017 fiscal year. The research on sponsored changeable message signs (continued from the previous year) was terminated by the Federa...

  6. 14 CFR 25.1701 - Definition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... on electrical devices, including those on relays, interrupters, switches, contactors, terminal blocks and circuit breakers, and other circuit protection devices. (4) Connectors, including feed-through... connections. (7) Electrical splices. (8) Materials used to provide additional protection for wires, including...

  7. 14 CFR 25.1701 - Definition.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... on electrical devices, including those on relays, interrupters, switches, contactors, terminal blocks and circuit breakers, and other circuit protection devices. (4) Connectors, including feed-through... connections. (7) Electrical splices. (8) Materials used to provide additional protection for wires, including...

  8. 47 CFR 15.240 - Operation in the band 433.5-434.5 MHz.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... commercial and industrial areas such as ports, rail terminals and warehouses. Two-way operation is permitted to interrogate and to load data into devices. Devices operated pursuant to the provisions of this...

  9. Development of simulation techniques suitable for the analysis of air traffic control situations and instrumentation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A terminal area simulation is described which permits analysis and synthesis of current and advanced air traffic management system configurations including ground and airborne instrumentation and new and modified aircraft characteristics. Ground elements in the simulation include navigation aids, surveillance radars, communication links, air-route structuring, ATC procedures, airport geometries and runway handling constraints. Airborne elements include traffic samples with individual aircraft performance and operating characteristics and aircraft navigation equipment. The simulation also contains algorithms for conflict detection, conflict resolution, sequencing and pilot-controller data links. The simulation model is used to determine the sensitivities of terminal area traffic flow, safety and congestion to aircraft performance characteristics, avionics systems, and other ATC elements.

  10. Analysis of dynamical response of air blast loaded safety device

    NASA Astrophysics Data System (ADS)

    Tropkin, S. N.; Tlyasheva, R. R.; Bayazitov, M. I.; Kuzeev, I. R.

    2018-03-01

    Equipment of many oil and gas processing plants in the Russian Federation is considerably worn-out. This causes the decrease of reliability and durability of equipment and rises the accident rate. An air explosion is the one of the most dangerous cases for plants in oil and gas industry, usually caused by uncontrolled emission and inflammation of oil products. Air explosion can lead to significant danger for life and health of plant staff, so it necessitates safety device usage. A new type of a safety device is designed. Numerical simulation is necessary to analyse design parameters and performance of the safety device, subjected to air blast loading. Coupled fluid-structure interaction analysis is performed to determine strength of the protective device and its performance. The coupled Euler-Lagrange method, allowable in Abaqus by SIMULIA, is selected as the most appropriate analysis tool to study blast wave interaction with the safety device. Absorption factors of blast wave are evaluated for the safety device. This factors allow one to assess efficiency of the safety device, and its main structural component – dampener. Usage of CEL allowed one to model fast and accurately the dampener behaviour, and to develop the parametric model to determine safety device sizes.

  11. 40 CFR 60.271 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (c) Control device means the air pollution control equipment used to remove particulate matter... air pollution control device. (e) Charge means the addition of iron and steel scrap or other materials... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  12. 40 CFR 60.271 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (c) Control device means the air pollution control equipment used to remove particulate matter... air pollution control device. (e) Charge means the addition of iron and steel scrap or other materials... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  13. 40 CFR 60.271 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (c) Control device means the air pollution control equipment used to remove particulate matter... air pollution control device. (e) Charge means the addition of iron and steel scrap or other materials... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  14. 40 CFR 60.271 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (c) Control device means the air pollution control equipment used to remove particulate matter... air pollution control device. (e) Charge means the addition of iron and steel scrap or other materials... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  15. 40 CFR 60.271 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (c) Control device means the air pollution control equipment used to remove particulate matter... air pollution control device. (e) Charge means the addition of iron and steel scrap or other materials... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  16. California; Northern Sierra Air Quality Management District; Approval of Air Plan Revisions; Wood Burning Devices

    EPA Pesticide Factsheets

    EPA is taking final action to approve a revision to the Northern Sierra Air Quality Management District (NSAQMD) portion of the California SIP concerning emissions of particulate matter (PM) from wood burning devices.

  17. Vapor-fed microfluidic hydrogen generator.

    PubMed

    Modestino, M A; Dumortier, M; Hosseini Hashemi, S M; Haussener, S; Moser, C; Psaltis, D

    2015-05-21

    Water-splitting devices that operate with humid air feeds are an attractive alternative for hydrogen production as the required water input can be obtained directly from ambient air. This article presents a novel proof-of-concept microfluidic platform that makes use of polymeric ion conductor (Nafion®) thin films to absorb water from air and performs the electrochemical water-splitting process. Modelling and experimental tools are used to demonstrate that these microstructured devices can achieve the delicate balance between water, gas, and ionic transport processes required for vapor-fed devices to operate continuously and at steady state, at current densities above 3 mA cm(-2). The results presented here show that factors such as the thickness of the Nafion films covering the electrodes, convection of air streams, and water content of the ionomer can significantly affect the device performance. The insights presented in this work provide important guidelines for the material requirements and device designs that can be used to create practical electrochemical hydrogen generators that work directly under ambient air.

  18. Effectiveness of ultraviolet devices and hydrogen peroxide systems for terminal room decontamination: Focus on clinical trials.

    PubMed

    Weber, David J; Rutala, William A; Anderson, Deverick J; Chen, Luke F; Sickbert-Bennett, Emily E; Boyce, John M

    2016-05-02

    Over the last decade, substantial scientific evidence has accumulated that indicates contamination of environmental surfaces in hospital rooms plays an important role in the transmission of key health care-associated pathogens (eg, methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, Clostridium difficile, Acinetobacter spp). For example, a patient admitted to a room previously occupied by a patient colonized or infected with one of these pathogens has a higher risk for acquiring one of these pathogens than a patient admitted to a room whose previous occupant was not colonized or infected. This risk is not surprising because multiple studies have demonstrated that surfaces in hospital rooms are poorly cleaned during terminal cleaning. To reduce surface contamination after terminal cleaning, no touch methods of room disinfection have been developed. This article will review the no touch methods, ultraviolet light devices, and hydrogen peroxide systems, with a focus on clinical trials which have used patient colonization or infection as an outcome. Multiple studies have demonstrated that ultraviolet light devices and hydrogen peroxide systems have been shown to inactivate microbes experimentally plated on carrier materials and placed in hospital rooms and to decontaminate surfaces in hospital rooms naturally contaminated with multidrug-resistant pathogens. A growing number of clinical studies have demonstrated that ultraviolet devices and hydrogen peroxide systems when used for terminal disinfection can reduce colonization or health care-associated infections in patients admitted to these hospital rooms. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Inertial impaction air sampling device

    DOEpatents

    Dewhurst, K.H.

    1990-05-22

    An inertial impactor is designed which is to be used in an air sampling device for collection of respirable size particles in ambient air. The device may include a graphite furnace as the impaction substrate in a small-size, portable, direct analysis structure that gives immediate results and is totally self-contained allowing for remote and/or personal sampling. The graphite furnace collects suspended particles transported through the housing by means of the air flow system, and these particles may be analyzed for elements, quantitatively and qualitatively, by atomic absorption spectrophotometry. 3 figs.

  20. Analyzing Single-Event Gate Ruptures In Power MOSFET's

    NASA Technical Reports Server (NTRS)

    Zoutendyk, John A.

    1993-01-01

    Susceptibilities of power metal-oxide/semiconductor field-effect transistors (MOSFET's) to single-event gate ruptures analyzed by exposing devices to beams of energetic bromine ions while applying appropriate bias voltages to source, gate, and drain terminals and measuring current flowing into or out of each terminal.

  1. 76 FR 67379 - Importation of Dracaena Plants From Costa Rica

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-01

    ... rooting zone for plants produced by air layering) to the farthest terminal growing point. Paragraph (y)(2... the soil line (or top of the rooting zone for plants produced by air layering) to the farthest...

  2. Generation of Combat Power by Insurgents: An Historical Analysis

    DTIC Science & Technology

    2013-06-13

    the concept of operations. Transportation incorporates military, commercial, and multinational assets. Transportation includes motor , rail, air...and water modes. Transportation nodes include motor , rail, air, and water terminal operations. Transportation also includes movement control and

  3. Compliance-Free, Digital SET and Analog RESET Synaptic Characteristics of Sub-Tantalum Oxide Based Neuromorphic Device.

    PubMed

    Abbas, Yawar; Jeon, Yu-Rim; Sokolov, Andrey Sergeevich; Kim, Sohyeon; Ku, Boncheol; Choi, Changhwan

    2018-01-19

    A two terminal semiconducting device like a memristor is indispensable to emulate the function of synapse in the working memory. The analog switching characteristics of memristor play a vital role in the emulation of biological synapses. The application of consecutive voltage sweeps or pulses (action potentials) changes the conductivity of the memristor which is considered as the fundamental cause of the synaptic plasticity. In this study, a neuromorphic device using an in-situ growth of sub-tantalum oxide switching layer is fabricated, which exhibits the digital SET and analog RESET switching with an electroforming process without any compliance current (compliance free). The process of electroforming and SET is observed at the positive sweeps of +2.4 V and +0.86 V, respectively, while multilevel RESET is observed with the consecutive negative sweeps in the range of 0 V to -1.2 V. The movement of oxygen vacancies and gradual change in the anatomy of the filament is attributed to digital SET and analog RESET switching characteristics. For the Ti/Ta 2 O 3-x /Pt neuromorphic device, the Ti top and Pt bottom electrodes are considered as counterparts of the pre-synaptic input terminal and a post-synaptic output terminal, respectively.

  4. The Economics of Air Cargo

    NASA Technical Reports Server (NTRS)

    Kersey, J. W.

    1972-01-01

    The economic factors involved in air cargo operations and air cargo marketing development are discussed. Specific steps which are followed by various airports to reduce operating costs are described. The economics of cargo handling within an airline are analyzed with respect to: (1) paperwork costs, (2) terminal costs, (3) line haul costs, and (4) claims costs.

  5. Final Environmental Assessment for the Proposed Antenna Construction at the Existing ADF Remote Terminal Facility, Buckley, Air Force Base, Colorado

    DTIC Science & Technology

    2004-09-01

    November. Buckley Air Force Base (BAFB). 2003a. Electronic mail correspondence from Janet Wade, Base Population. July . Buckley Air Force Base...please contact Amy Pallante , our Section 106 Compliance Coordinator, at (303) 866-4678. Sincerely, ~~=i~::t State Historic Preservation Officer

  6. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  7. Air elimination capability in rapid infusion systems.

    PubMed

    Zoremba, N; Gruenewald, C; Zoremba, M; Rossaint, R; Schaelte, G

    2011-11-01

    Pressure infusion devices are used in clinical practice to apply large volumes of fluid over a short period of time. Although air infusion is a major complication, they have limited capability to detect and remove air during pressure infusion. In this investigation, we tested the air elimination capabilities of the Fluido(®) (The Surgical Company), Level 1(®) (Level 1 Technologies Inc.) and Ranger(®) (Augustine Medical GmbH) pressure infusion devices. Measurements were undertaken with a crystalloid solution during an infusion flow of 100, 200, 400 and 800 ml.min(-1). Four different volumes of air (25, 50, 100 and 200 ml) were injected as boluses in one experimental setting, or infused continuously over the time needed to perfuse 2 l saline in the other setting. The perfusion fluid was collected in an airtight infusion bag and the amount of air obtained in the bag was measured. The delivered air volume was negligible and would not cause any significant air embolism in all experiments. In our experimental setting, we found, during high flow, an increased amount of uneliminated air in all used devices compared with lower perfusion flows. All tested devices had a good air elimination capability. The use of ultrasonic air detection coupled with an automatic shutoff is a significant safety improvement and can reliably prevent accidental air embolism at rapid flows. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  8. Questions Students Ask: About Terminal Velocity.

    ERIC Educational Resources Information Center

    Meyer, Earl R.; Nelson, Jim

    1984-01-01

    If a ball were given an initial velocity in excess of its terminal velocity, would the upward force of air resistance (a function of velocity) be greater than the downward force of gravity and thus push the ball back upwards? An answer to this question is provided. (JN)

  9. 40 CFR 63.11080 - What is the purpose of this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Distribution Bulk Terminals, Bulk Plants, and Pipeline Facilities What This Subpart Covers § 63.11080 What is... practices for hazardous air pollutants (HAP) emitted from area source gasoline distribution bulk terminals, bulk plants, and pipeline facilities. This subpart also establishes requirements to demonstrate...

  10. COBEL model as part of a terminal-area ceiling and visibility (C and V) nowcast system : a progress report

    DOT National Transportation Integrated Search

    1996-07-18

    The Federal Aviation Administration (FAA) Integrated Terminal Weather System (ITWS) is supporting the development of products aimed at providing automated guidance to the air traffic managers for the anticipation of changes in ceiling and visibility ...

  11. Detail of array panels, Face B, with active and terminated ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail of array panels, Face B, with active and terminated dipole elements - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, Techinical Equipment Building, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  12. 75 FR 65551 - Notice of Passenger Facility Charge (PFC) Approvals and Disapprovals

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-25

    ... at a $3.00 PFC Level: New terminal development schematic preliminary engineering study and design... for Collection and Use: Air carrier apron. Pavement condition inventory. New terminal building... construction. De-icing treatment plant. Domestic water service. CTX design and installation. Landside planning...

  13. 14 CFR 129.11 - Amendment, suspension and termination of operations specifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Amendment, suspension and termination of operations specifications. 129.11 Section 129.11 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... AND OPERATIONS OPERATIONS: FOREIGN AIR CARRIERS AND FOREIGN OPERATORS OF U.S.-REGISTERED AIRCRAFT...

  14. 14 CFR 129.11 - Amendment, suspension and termination of operations specifications.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Amendment, suspension and termination of operations specifications. 129.11 Section 129.11 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... AND OPERATIONS OPERATIONS: FOREIGN AIR CARRIERS AND FOREIGN OPERATORS OF U.S.-REGISTERED AIRCRAFT...

  15. 14 CFR 129.11 - Amendment, suspension and termination of operations specifications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Amendment, suspension and termination of operations specifications. 129.11 Section 129.11 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... AND OPERATIONS OPERATIONS: FOREIGN AIR CARRIERS AND FOREIGN OPERATORS OF U.S.-REGISTERED AIRCRAFT...

  16. Attitudes and motivational factors in terminal area air traffic control work.

    DOT National Transportation Integrated Search

    1971-07-01

    A sample of 614 journeymen terminal ATCSs at 17 high-density IFR airports, and 514 ATC trainees were administered a questionnaire which asked them to list what they liked best and what they liked least about ATC work in general; in addition, ATCSs ma...

  17. A 2D Material based Gate Tunable Memristive Device for Emulating Modulatory Input-dependent Hetero-synaptic Plasticity.

    NASA Astrophysics Data System (ADS)

    Yan, Xiaodong; Tian, He; Xie, Yujun; Kostelec, Andrew; Zhao, Huan; Cha, Judy J.; Tice, Jesse; Wang, Han

    Modulatory input-dependent plasticity is a well-known type of hetero-synaptic response where the release of neuromodulators can alter the efficacy of neurotransmission in a nearby chemical synapse. Solid-state devices that can mimic such phenomenon are desirable for enhancing the functionality and reconfigurability of neuromorphic electronics. In this work, we demonstrated a tunable artificial synaptic device concept based on the properties of graphene and tin oxide that can mimic the modulatory input-dependent plasticity. By using graphene as the contact electrode, a third electrode terminal can be used to modulate the conductive filament formation in the vertical tin oxide based resistive memory device. The resulting synaptic characteristics of this device, in terms of the profile of synaptic weight change and the spike-timing-dependent-plasticity, is tunable with the bias at the modulating terminal. Furthermore, the synaptic response can be reconfigured between excitatory and inhibitory modes by this modulating bias. The operation mechanism of the device is studied with combined experimental and theoretical analysis. The device is attractive for application in neuromorphic electronics. This work is supported by ARO and NG-ION2 at USC.

  18. 42 CFR 50.308 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... pregnancies. 50.308 Section 50.308 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... pregnancies. Federal financial participation is available with respect to the cost of drugs or devices to... an ectopic pregnancy. ...

  19. 42 CFR 50.308 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pregnancies. 50.308 Section 50.308 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... pregnancies. Federal financial participation is available with respect to the cost of drugs or devices to... an ectopic pregnancy. ...

  20. 42 CFR 50.308 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... pregnancies. 50.308 Section 50.308 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... pregnancies. Federal financial participation is available with respect to the cost of drugs or devices to... an ectopic pregnancy. ...

  1. 42 CFR 50.308 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... pregnancies. 50.308 Section 50.308 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... pregnancies. Federal financial participation is available with respect to the cost of drugs or devices to... an ectopic pregnancy. ...

  2. 42 CFR 50.308 - Drugs and devices and termination of ectopic pregnancies.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... pregnancies. 50.308 Section 50.308 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN... pregnancies. Federal financial participation is available with respect to the cost of drugs or devices to... an ectopic pregnancy. ...

  3. Mobile selected ion flow tube mass spectrometry (SIFT-MS) devices and their use for pollution exposure monitoring in breath and ambient air-pilot study.

    PubMed

    Storer, Malina; Salmond, Jennifer; Dirks, Kim N; Kingham, Simon; Epton, Michael

    2014-09-01

    Studies of health effects of air pollution exposure are limited by inability to accurately determine dose and exposure of air pollution in field trials. We explored the feasibility of using a mobile selected ion flow tube mass spectrometry (SIFT-MS) device, housed in a van, to determine ambient air and breath levels of benzene, xylene and toluene following exercise in areas of high motor vehicle traffic. The breath toluene, xylene and benzene concentration of healthy subjects were measured before and after exercising close to a busy road. The concentration of the volatile organic compounds (VOCs), in ambient air were also analysed in real time. Exercise close to traffic pollution is associated with a two-fold increase in breath VOCs (benzene, xylene and toluene) with levels returning to baseline within 20 min. This effect is not seen when exercising away from traffic pollution sources. Situating the testing device 50 m from the road reduced any confounding due to VOCs in the inspired air prior to the breath testing manoeuvre itself. Real-time field testing for air pollution exposure is possible using a mobile SIFT-MS device. This device is suitable for exploring exposure and dose relationships in a number of large scale field test scenarios.

  4. 29 CFR 1917.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... terminal and used with a vessel's cargo gear to load or unload by means of married falls. Inspection, as... examination of all visible parts of the device. Intermodal container means a reusable cargo container of a... terminal immediately adjacent to a vessel berth and used in the direct transfer of cargo between the...

  5. 29 CFR 1917.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... terminal and used with a vessel's cargo gear to load or unload by means of married falls. Inspection, as... examination of all visible parts of the device. Intermodal container means a reusable cargo container of a... terminal immediately adjacent to a vessel berth and used in the direct transfer of cargo between the...

  6. 29 CFR 1917.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... terminal and used with a vessel's cargo gear to load or unload by means of married falls. Inspection, as... examination of all visible parts of the device. Intermodal container means a reusable cargo container of a... terminal immediately adjacent to a vessel berth and used in the direct transfer of cargo between the...

  7. 29 CFR 1917.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... terminal and used with a vessel's cargo gear to load or unload by means of married falls. Inspection, as... examination of all visible parts of the device. Intermodal container means a reusable cargo container of a... terminal immediately adjacent to a vessel berth and used in the direct transfer of cargo between the...

  8. 29 CFR 1917.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... terminal and used with a vessel's cargo gear to load or unload by means of married falls. Inspection, as... examination of all visible parts of the device. Intermodal container means a reusable cargo container of a... terminal immediately adjacent to a vessel berth and used in the direct transfer of cargo between the...

  9. Tuned intake air system for a rotary engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corbett, W.D.

    This patent describes a rotary internal combustion engine for an outboard board motor. It comprises a plenum chamber attached to the rear of the engine; and the plenum chamber including an inner wall attached to the exhaust manifold; an inlet conduit connecting the cooling air exit passage and the inlet air opening; an outlet conduit connecting the outlet air opening and the combustion air inlet; and the outlet conduit terminating in a combustion air outlet in the inner wall of the plenum chamber.

  10. 40 CFR 60.271a - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the top of an AOD vessel. Control device means the air pollution control equipment used to remove... vessel to the air pollution control device. Charge means the addition of iron and steel scrap or other... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  11. 40 CFR 60.271a - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the top of an AOD vessel. Control device means the air pollution control equipment used to remove... vessel to the air pollution control device. Charge means the addition of iron and steel scrap or other... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  12. 40 CFR 60.271a - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the top of an AOD vessel. Control device means the air pollution control equipment used to remove... vessel to the air pollution control device. Charge means the addition of iron and steel scrap or other... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  13. 40 CFR 60.271a - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the top of an AOD vessel. Control device means the air pollution control equipment used to remove... vessel to the air pollution control device. Charge means the addition of iron and steel scrap or other... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  14. 40 CFR 60.271a - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the top of an AOD vessel. Control device means the air pollution control equipment used to remove... vessel to the air pollution control device. Charge means the addition of iron and steel scrap or other... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...

  15. Wave energy absorption by a floating air bag

    NASA Astrophysics Data System (ADS)

    Kurniawan, A.; Chaplin, J. R.; Greaves, D. M.; Hann, M.

    2017-02-01

    A floating air bag, ballasted in water, expands and contracts as it heaves under wave action. Connecting the bag to a secondary volume via a turbine transforms the bag into a device capable of generating useful energy from the waves. Small-scale measurements of the device reveal some interesting properties, which are successfully predicted numerically. Owing to its compressibility, the device can have a heave resonance period longer than that of a rigid device of the same shape and size, without any phase control. Furthermore, varying the amount of air in the bag is found to change its shape and hence its dynamic response, while varying the turbine damping or the air volume ratio changes the dynamic response without changing the shape.

  16. Advanced Command Destruct System (ACDS) Enhanced Flight Termination System (EFTS)

    NASA Technical Reports Server (NTRS)

    Tow, David K.

    2011-01-01

    This presentation provides information on the development, integration, and operational usage of the Enhanced Flight Termination System (EFTS) at NASA Dryden Flight Research Center and Air Force Flight Test Center. The presentation will describe the efforts completed to certify the system and acquire approval for operational usage, the efforts to integrate the system into the NASA Dryden existing flight termination infrastructure, and the operational support of aircraft with EFTS at Edwards AFB.

  17. Electron Transport in Multi-Terminal Graphene Nanodevice with Inclined Cross Structures

    NASA Astrophysics Data System (ADS)

    Ye, En-Jia; Shi, Yi-Jian; Zhao, Xuean

    2014-12-01

    The DC and AC transport properties are investigated in multi-terminal graphene nanoribbon (GNR) devices. The devices are composed of three or four graphene ribbons connected with different angles. It is found that DC and AC conductances depend on the structural configurations and ribbon properties. In the vicinity of Dirac point, the intersection of graphene ribbons forms band mixing and results in resonant or anti-resonant states. The edge and width, as well as, the angles of the graphene ribbons influence the DC and AC transport properties drastically. These properties can be used to build future graphene-based nanoelectronics.

  18. Laser decontamination of the radioactive lightning rods

    NASA Astrophysics Data System (ADS)

    Potiens, A. J.; Dellamano, J. C.; Vicente, R.; Raele, M. P.; Wetter, N. U.; Landulfo, E.

    2014-02-01

    Between 1970 and 1980 Brazil experienced a significant market for radioactive lightning rods (RLR). The device consists of an air terminal with one or more sources of americium-241 attached to it. The sources were used to ionize the air around them and to increase the attraction of atmospheric discharges. Because of their ineffectiveness, the nuclear regulatory authority in Brazil suspended the license for manufacturing, commerce and installation of RLR in 1989, and determined that the replaced RLR were to be collected to a centralized radioactive waste management facility for treatment. The first step for RLR treatment is to remove the radioactive sources. Though they can be easily removed, some contaminations are found all over the remaining metal scrap that must decontaminated for release, otherwise it must be treated as radioactive waste. Decontamination using various chemicals has proven to be inefficient and generates large amounts of secondary wastes. This work shows the preliminary results of the decontamination of 241Am-contaminated metal scrap generated in the treatment of radioactive lightning rods applying laser ablation. A Nd:YAG nanoseconds laser was used with 300 mJ energy leaving only a small amount of secondary waste to be treated.

  19. Self-assembling Gold Nanoparticle Monolayers in a Three-phase System - Overcoming Ligand Size Limitations

    NASA Astrophysics Data System (ADS)

    Yang, Guang; Nanda, Jagjit; Wang, Boya; Chen, Gang; Hallinan, Daniel T., Jr.

    An effective self-assembly technique was developed to prepare centimeter-scale monolayer gold nanoparticle (Au NP) films of long-range order with hydrophobic ligands. Aqueous Au NPs were entrapped in the organic/aqueous interface where the Au NP surface was in situ modified with different types of amine ligands, including amine-terminated polystyrene. The Au NPs then spontaneously relocated to the air/water interface to form an NP monolayer. The spontaneous formation of an Au NP film at the organic/water interface was due to the minimization of the system Helmholtz free energy. Self-assembled Au NP films has a hexagonal close packed structure. The interparticle spacing was dictated by the amine ligand length. Thus-assembled Au NP monolayers exhibit tunable surface plasma resonance and excellent spacial homogeneity of surface-enhanced Raman-scattering. The ``air/water/oil'' self-assembly method developed in this study not only benefits the fundamental understanding of NP ligand conformations, but is also promising to scale up the manufacture of plasmonic nanoparticle devices with precisely designed optical properties. This study was financially supported by start-up funding supplied by the Florida State University and the FAMU-FSU College of Engineering.

  20. An analysis of voice communication in a simulated approach control environment : final report.

    DOT National Transportation Integrated Search

    1998-05-01

    This report consists of an analysis of simulated terminal radar approach control (TRACON) air traffic control communications. Twenty-four full performance level air traffic controllers (FPLATC) from 2 TRACON facilities participated in the simulation ...

  1. EPA Requires Beemsterboer and KCBX to Take Action

    EPA Pesticide Factsheets

    In response to complaints of fugitive pet coke dust, EPA issued Clean Air Act Section 114 information request letters to KCBX Terminals and Beemsterboer Slag petroleum coke facilities, and ordered onsite air quality monitoring and petcoke sample analysis.

  2. What is EPA Doing about Pet Coke in Chicago?

    EPA Pesticide Factsheets

    In response to complaints of windblown dust believed to originate from petroleum coke (petcoke) storage pile sites, operated by KCBX Terminals and Beemsterboer Slag; EPA ordered sample analysis and air quality monitoring under the Clean Air Act.

  3. Laboratory Development of a Passive Sampling Device for Hydrazines in Ambient Air

    DTIC Science & Technology

    1990-05-30

    of dilution air . Conditioned house- compressed air is used as the diluent. The conditioning procedure consists of passing the house air through a...Device N4 for Hydrazines in Ambient Air P. A. TAFFE,* K. P. CROSSMAN,* S. L. ROSE-PEHRSSON, AND J. R. WYATT 0 Chemistry Dynamics and Diagnostic Branch...Ambient Air 6. AUTHOR(S) Taffe,* P. A., Crossman,* K. P., Wyatt, J. R., and Rose-Pehrsson, S. L. 7. PERFORMING ORGANIZATION NAME(S) AND ADORESS(ES) 8

  4. 50 CFR 14.110 - Terminal facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Terminal facilities. 14.110 Section 14.110 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING..., ectoparasites, and pests of mammals or birds; (3) Sufficient fresh air to allow the animals to breathe normally...

  5. Do seat belts and air bags reduce mortality and injury severity after car accidents?

    PubMed

    Cummins, Justin S; Koval, Kenneth J; Cantu, Robert V; Spratt, Kevin F

    2011-03-01

    We studied National Trauma Data Bank data to determine the effectiveness of car safety devices in reducing mortality and injury severity in 184,992 patients between 1988 and 2004. Safety device variables were seat belt used plus air bag deployed; only seat belt used; only air bag deployed; and, as explicitly coded, no device used. Overall mortality was 4.17%. Compared with the no-device group, the seat-belt-plus-air-bag group had a 67% reduction in mortality (adjusted odds ratio [AOR], 0.33; 99% confidence interval [CI], 0.28-0.39), the seatbelt- only group had a 51% mortality reduction (AOR, 0.49; 99% CI, 0.45-0.52), and the air-bag-only group had a 32% mortality reduction (AOR, 0.68, 99% CI, 0.57-0.80). Injury Severity Scores showed a similar pattern.

  6. Emission inventory estimation of an intercity bus terminal.

    PubMed

    Qiu, Zhaowen; Li, Xiaoxia; Hao, Yanzhao; Deng, Shunxi; Gao, H Oliver

    2016-06-01

    Intercity bus terminals are hotspots of air pollution due to concentrated activities of diesel buses. In order to evaluate the bus terminals' impact on air quality, it is necessary to estimate the associated mobile emission inventories. Since the vehicles' operating condition at the bus terminal varies significantly, conventional calculation of the emissions based on average emission factors suffers the loss of accuracy. In this study, we examined a typical intercity bus terminal-the Southern City Bus Station of Xi'an, China-using a multi-scale emission model-(US EPA's MOVES model)-to quantity the vehicle emission inventory. A representative operating cycle for buses within the station is constructed. The emission inventory was then estimated using detailed inputs including vehicle ages, operating speeds, operating schedules, and operating mode distribution, as well as meteorological data (temperature and humidity). Five functional areas (bus yard, platforms, disembarking area, bus travel routes within the station, and bus entrance/exit routes) at the terminal were identified, and the bus operation cycle was established using the micro-trip cycle construction method. Results of our case study showed that switching to compressed natural gas (CNG) from diesel fuel could reduce PM2.5 and CO emissions by 85.64 and 6.21 %, respectively, in the microenvironment of the bus terminal. When CNG is used, tail pipe exhaust PM2.5 emission is significantly reduced, even less than brake wear PM2.5. The estimated bus operating cycles can also offer researchers and policy makers important information for emission evaluation in the planning and design of any typical intercity bus terminals of a similar scale.

  7. Short-term exposure to PM 10, PM 2.5, ultrafine particles and CO 2 for passengers at an intercity bus terminal

    NASA Astrophysics Data System (ADS)

    Cheng, Yu-Hsiang; Chang, Hsiao-Peng; Hsieh, Cheng-Ju

    2011-04-01

    The Taipei Bus Station is the main transportation hub for over 50 bus routes to eastern, central, and southern Taiwan. Daily traffic volume at this station is about 2500 vehicles, serving over 45,000 passengers daily. The station is a massive 24-story building housing a bus terminal, a business hotel, a shopping mall, several cinemas, offices, private residential suites, and over 900 parking spaces. However, air quality inside this bus terminal is a concern as over 2500 buses are scheduled to run daily. This study investigates the PM 10, PM 2.5, UFP and CO 2 levels inside and outside the bus terminal. All measurements were taken between February and April 2010. Measurement results show that coarse PM inside the bus terminal was resuspended by the movement of large numbers of passengers. The fine and ultrafine PM in the station concourse were from outside vehicles. Moreover, fine and ultrafine PM at waiting areas were exhausted directly from buses in the building. The CO 2 levels at waiting areas were likely elevated by bus exhaust and passengers exhaling. The PM 10, PM 2.5 and CO 2 levels at the bus terminal were lower than Taiwan's EPA suggested standards for indoor air quality. However, UFP levels at the bus terminal were significantly higher than those in the urban background by about 10 times. Therefore, the effects of UFPs on the health of passengers and workers must be addressed at this bus terminal since the levels of UFPs are higher than >1.0 × 10 5 particles cm -3.

  8. Graphene-Nanodiamond Heterostructures and their application to High Current Devices

    PubMed Central

    Zhao, Fang; Vrajitoarea, Andrei; Jiang, Qi; Han, Xiaoyu; Chaudhary, Aysha; Welch, Joseph O.; Jackman, Richard B.

    2015-01-01

    Graphene on hydrogen terminated monolayer nanodiamond heterostructures provides a new way to improve carrier transport characteristics of the graphene, offering up to 60% improvement when compared with similar graphene on SiO2/Si substrates. These heterostructures offers excellent current-carrying abilities whilst offering the prospect of a fast, low cost and easy methodology for device applications. The use of ND monolayers is also a compatible technology for the support of large area graphene films. The nature of the C-H bonds between graphene and H-terminated NDs strongly influences the electronic character of the heterostructure, creating effective charge redistribution within the system. Field effect transistors (FETs) have been fabricated based on this novel herterostructure to demonstrate device characteristics and the potential of this approach. PMID:26350107

  9. Multi-terminal memtransistors from polycrystalline monolayer molybdenum disulfide

    NASA Astrophysics Data System (ADS)

    Sangwan, Vinod K.; Lee, Hong-Sub; Bergeron, Hadallia; Balla, Itamar; Beck, Megan E.; Chen, Kan-Sheng; Hersam, Mark C.

    2018-02-01

    Memristors are two-terminal passive circuit elements that have been developed for use in non-volatile resistive random-access memory and may also be useful in neuromorphic computing. Memristors have higher endurance and faster read/write times than flash memory and can provide multi-bit data storage. However, although two-terminal memristors have demonstrated capacity for basic neural functions, synapses in the human brain outnumber neurons by more than a thousandfold, which implies that multi-terminal memristors are needed to perform complex functions such as heterosynaptic plasticity. Previous attempts to move beyond two-terminal memristors, such as the three-terminal Widrow-Hoff memristor and field-effect transistors with nanoionic gates or floating gates, did not achieve memristive switching in the transistor. Here we report the experimental realization of a multi-terminal hybrid memristor and transistor (that is, a memtransistor) using polycrystalline monolayer molybdenum disulfide (MoS2) in a scalable fabrication process. The two-dimensional MoS2 memtransistors show gate tunability in individual resistance states by four orders of magnitude, as well as large switching ratios, high cycling endurance and long-term retention of states. In addition to conventional neural learning behaviour of long-term potentiation/depression, six-terminal MoS2 memtransistors have gate-tunable heterosynaptic functionality, which is not achievable using two-terminal memristors. For example, the conductance between a pair of floating electrodes (pre- and post-synaptic neurons) is varied by a factor of about ten by applying voltage pulses to modulatory terminals. In situ scanning probe microscopy, cryogenic charge transport measurements and device modelling reveal that the bias-induced motion of MoS2 defects drives resistive switching by dynamically varying Schottky barrier heights. Overall, the seamless integration of a memristor and transistor into one multi-terminal device could enable complex neuromorphic learning and the study of the physics of defect kinetics in two-dimensional materials.

  10. 40 CFR 63.9020 - What performance tests and other procedures must I use?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Hydrochloric Acid Production...) If you use a caustic scrubber control device or a water scrubber control device, the design...

  11. 40 CFR 62.14595 - What are the operator training and qualification requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... charging, and shutdown procedures. (iv) Combustion controls and monitoring. (v) Operation of air pollution... the incinerator and air pollution control devices. (vii) Actions to correct malfunctions or conditions... requirements. (xiii) Methods to continuously monitor CISWI unit and air pollution control device operating...

  12. 40 CFR 62.14595 - What are the operator training and qualification requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... charging, and shutdown procedures. (iv) Combustion controls and monitoring. (v) Operation of air pollution... the incinerator and air pollution control devices. (vii) Actions to correct malfunctions or conditions... requirements. (xiii) Methods to continuously monitor CISWI unit and air pollution control device operating...

  13. The influence of air bags and restraining devices on extremity injuries in motor vehicle collisions.

    PubMed

    McGovern, M K; Murphy, R X; Okunski, W J; Wasser, T E

    2000-05-01

    The influence of air bags and other restraining devices on injury after motor vehicle collisions is not well defined. This study examined the relationship between the use of restraining devices and the incidence of extremity injuries in motor vehicle collisions. A retrospective analysis was performed on motor vehicle collision data submitted to the Pennsylvania Trauma Outcome Study database from 1990 through 1995. Criteria for submission included trauma patients who were admitted to the intensive care unit, who died during hospitalization, who were hospitalized for more than 72 hours, or who were transferred in or out of the receiving hospital. A total of 21,875 patients met these criteria. These patients were analyzed for the presence or absence of upper and lower extremity injuries and were compared based on their use of restraining devices. Restraining devices were categorized into four groups: air bag alone, air bag and seat belt, seat belt or carseat without air bag, and no restraining device. Statistical analysis was performed using the chi-squared test of association. For contingency tables with small expected frequencies, Fisher's exact test was used. Study participants included 11,688 men and 10,185 women with a mean age of 38 +/- 20 years. There were 16,033 drivers and 5,842 passengers. Air bags were deployed in 472 instances. In 297 of these cases, additional restraint was provided with a seat belt. In 6,632 cases, air bags were not deployed; however, patients were restrained with either a seat belt or a carseat. In 14,771 cases, patients were not restrained. When comparing restraining devices as a group vs. no restraint, there was a significant decrease in the incidence of upper (p = 0.018) and lower (p < 0.001) extremity injuries. Air bags, however, were associated with an increased incidence of both upper (p = 0.033) and lower (p = 0.002) extremity injuries when compared with no restraint or when compared among patients who were restrained. As a group, restraining devices decrease the incidence of upper and lower extremity trauma sustained by patients injured in motor vehicle collisions. Air bags, however, are associated with an increased incidence of upper and lower extremity injuries when compared with seat belts alone or when no restraining devices are used.

  14. 49 CFR 232.205 - Class I brake test-initial terminal inspection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... test shall be conducted as follows: (A) Charge the air brake system to the pressure at which the train... equivalent pressure maintaining locomotive brake valve, a railroad may use the Air Flow Method Test as an...) Charge the air brake system to the pressure at which the train will be operated, and the pressure at the...

  15. 49 CFR 232.205 - Class I brake test-initial terminal inspection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... test shall be conducted as follows: (A) Charge the air brake system to the pressure at which the train... equivalent pressure maintaining locomotive brake valve, a railroad may use the Air Flow Method Test as an...) Charge the air brake system to the pressure at which the train will be operated, and the pressure at the...

  16. 49 CFR 232.205 - Class I brake test-initial terminal inspection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... test shall be conducted as follows: (A) Charge the air brake system to the pressure at which the train... equivalent pressure maintaining locomotive brake valve, a railroad may use the Air Flow Method Test as an...) Charge the air brake system to the pressure at which the train will be operated, and the pressure at the...

  17. 49 CFR 232.205 - Class I brake test-initial terminal inspection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... test shall be conducted as follows: (A) Charge the air brake system to the pressure at which the train... equivalent pressure maintaining locomotive brake valve, a railroad may use the Air Flow Method Test as an...) Charge the air brake system to the pressure at which the train will be operated, and the pressure at the...

  18. Dynamic airspace configuration algorithms for next generation air transportation system

    NASA Astrophysics Data System (ADS)

    Wei, Jian

    The National Airspace System (NAS) is under great pressure to safely and efficiently handle the record-high air traffic volume nowadays, and will face even greater challenge to keep pace with the steady increase of future air travel demand, since the air travel demand is projected to increase to two to three times the current level by 2025. The inefficiency of traffic flow management initiatives causes severe airspace congestion and frequent flight delays, which cost billions of economic losses every year. To address the increasingly severe airspace congestion and delays, the Next Generation Air Transportation System (NextGen) is proposed to transform the current static and rigid radar based system to a dynamic and flexible satellite based system. New operational concepts such as Dynamic Airspace Configuration (DAC) have been under development to allow more flexibility required to mitigate the demand-capacity imbalances in order to increase the throughput of the entire NAS. In this dissertation, we address the DAC problem in the en route and terminal airspace under the framework of NextGen. We develop a series of algorithms to facilitate the implementation of innovative concepts relevant with DAC in both the en route and terminal airspace. We also develop a performance evaluation framework for comprehensive benefit analyses on different aspects of future sector design algorithms. First, we complete a graph based sectorization algorithm for DAC in the en route airspace, which models the underlying air route network with a weighted graph, converts the sectorization problem into the graph partition problem, partitions the weighted graph with an iterative spectral bipartition method, and constructs the sectors from the partitioned graph. The algorithm uses a graph model to accurately capture the complex traffic patterns of the real flights, and generates sectors with high efficiency while evenly distributing the workload among the generated sectors. We further improve the robustness and efficiency of the graph based DAC algorithm by incorporating the Multilevel Graph Partitioning (MGP) method into the graph model, and develop a MGP based sectorization algorithm for DAC in the en route airspace. In a comprehensive benefit analysis, the performance of the proposed algorithms are tested in numerical simulations with Enhanced Traffic Management System (ETMS) data. Simulation results demonstrate that the algorithmically generated sectorizations outperform the current sectorizations in different sectors for different time periods. Secondly, based on our experience with DAC in the en route airspace, we further study the sectorization problem for DAC in the terminal airspace. The differences between the en route and terminal airspace are identified, and their influence on the terminal sectorization is analyzed. After adjusting the graph model to better capture the unique characteristics of the terminal airspace and the requirements of terminal sectorization, we develop a graph based geometric sectorization algorithm for DAC in the terminal airspace. Moreover, the graph based model is combined with the region based sector design method to better handle the complicated geometric and operational constraints in the terminal sectorization problem. In the benefit analysis, we identify the contributing factors to terminal controller workload, define evaluation metrics, and develop a bebefit analysis framework for terminal sectorization evaluation. With the evaluation framework developed, we demonstrate the improvements on the current sectorizations with real traffic data collected from several major international airports in the U.S., and conduct a detailed analysis on the potential benefits of dynamic reconfiguration in the terminal airspace. Finally, in addition to the research on the macroscopic behavior of a large number of aircraft, we also study the dynamical behavior of individual aircraft from the perspective of traffic flow management. We formulate the mode-confusion problem as hybrid estimation problem, and develop a state estimation algorithm for the linear hybrid system with continuous-state-dependent transitions based on sparse observations. We also develop an estimated time of arrival prediction algorithm based on the state-dependent transition hybrid estimation algorithm, whose performance is demonstrated with simulations on the landing procedure following the Continuous Descend Approach (CDA) profile.

  19. High-velocity, multistage, nozzled, ion driven wind generator and method of operation of the same adaptable to mesoscale realization

    NASA Technical Reports Server (NTRS)

    Rickard, Matthew J. A. (Inventor); Dunn-Rankin, Derek (Inventor)

    2011-01-01

    Gas flows of modest velocities are generated when an organized ion flux in an electric field initiates an ion-driven wind of neutral molecules. When a needle in ambient air is electrically charged to a potential sufficient to produce a corona discharge near its tip, such a gas flow can be utilized downstream of a ring-shaped or other permeable earthed electrode. In view of the potential practical applications of such devices, as they represent blowers with no moving parts, a methodology for increasing their flow velocities includes exploitation of the divergence of electric field lines, avoidance of regions of high curvature on the second electrode, control of atmospheric humidity, and the use of linear arrays of stages, terminating in a converging nozzle. The design becomes particularly advantageous when implemented in mesoscale domains.

  20. Variable oxygen/nitrogen enriched intake air system for internal combustion engine applications

    DOEpatents

    Poola, Ramesh B.; Sekar, Ramanujam R.; Cole, Roger L.

    1997-01-01

    An air supply control system for selectively supplying ambient air, oxygen enriched air and nitrogen enriched air to an intake of an internal combustion engine includes an air mixing chamber that is in fluid communication with the air intake. At least a portion of the ambient air flowing to the mixing chamber is selectively diverted through a secondary path that includes a selectively permeable air separating membrane device due a differential pressure established across the air separating membrane. The permeable membrane device separates a portion of the nitrogen in the ambient air so that oxygen enriched air (permeate) and nitrogen enriched air (retentate) are produced. The oxygen enriched air and the nitrogen enriched air can be selectively supplied to the mixing chamber or expelled to atmosphere. Alternatively, a portion of the nitrogen enriched air can be supplied through another control valve to a monatomic-nitrogen plasma generator device so that atomic nitrogen produced from the nitrogen enriched air can be then injected into the exhaust of the engine. The oxygen enriched air or the nitrogen enriched air becomes mixed with the ambient air in the mixing chamber and then the mixed air is supplied to the intake of the engine. As a result, the air being supplied to the intake of the engine can be regulated with respect to the concentration of oxygen and/or nitrogen.

  1. Operational test results of the passive final approach spacing tool

    DOT National Transportation Integrated Search

    1997-06-01

    A prototype decision support tool for terminal area air traffic controllers, : referred to as the Final Approach Spacing Tool (FAST), was recently evaluated in : operation with live air traffic at the Dallas/Fort Worth, Texas Airport, : Controllers u...

  2. Concept for a Satellite-Based Advanced Air Traffic Management System : Volume 10. Subsystem Performance Requirements.

    DOT National Transportation Integrated Search

    1974-02-01

    The volume presents the results of the subsystem performance requirements study for an Advanced Air Traffic Management System (AATMS). The study determined surveillance and navigation subsystem requirements for terminal and enroute area operations. I...

  3. Fabrication of biofunctional nanomaterials via Escherichia coli OmpF protein air/water interface insertion/integration with copolymeric amphiphiles.

    PubMed

    Ho, Dean; Chang, Stacy; Montemagno, Carlo D

    2006-06-01

    Fabrication of next-generation biologically active materials will involve the integration of proteins with synthetic membrane materials toward a wide spectrum of applications in nanoscale medicine, including high-throughput drug testing, energy conversion for powering medical devices, and bio-cloaking films for mimicry of cellular membrane surfaces toward the enhancement of implant biocompatibility. We have used ABA triblock copolymer membranes (PMOXA-PDMS-PMOXA) of varied thicknesses as platform materials for Langmuir film-based functionalization with the OmpF pore protein from Escherichia coli by fabricating monolayers of copolymer amphiphile-protein complexes on the air/water interface. Here we demonstrate that the ability for protein insertion at the air/water interface during device fabrication is dependent upon the initial surface coverage with the copolymer as well as copolymer thickness. Methacrylate-terminated block copolymer structures that were 4 nm (4METH) and 8 nm (8METH) in length were used as the protein reconstitution matrix, whereas a 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) lipid (~4 nm thickness) was used as a comparison to demonstrate the effects of copolymer length on protein integration capabilities. Wilhemy surface pressure measurements (mN/m) revealed a greater protein insertion in the 4METH and POPC structures compared with the 8METH structure, indicating that shorter copolymer chains possess enhanced biomimicry of natural lipid-based membranes. In addition, comparisons between the isothermal characteristics of the 4METH, 8METH, and POPC membranes reveal that phase transitions of the 4METH resemble a blend of the 8METH and POPC materials, indicating that the 4METH chain may possess hybrid properties of both copolymers and lipids. Furthermore, we have shown that following the deposition of the amphiphilic materials on the air/water interface, the OmpF can be deposited directly on top of the amphiphiles (surface addition), thus effectively further enhancing protein insertion because of the buoying effects of the membranes. These characteristics of Langmuir-Blodgett-based fabrication of copolymer-biomolecule hybrids represent a synthesis strategy for next-generation biomedical materials.

  4. Mechanical model for simulating the conditioning of air in the respiratory tract.

    PubMed

    Bergonse Neto, Nelson; Von Bahten, Luiz Carlos; Moura, Luís Mauro; Coelho, Marlos de Souza; Stori Junior, Wilson de Souza; Bergonse, Gilberto da Fontoura Rey

    2007-01-01

    To create a mechanical model that could be regulated to simulate the conditioning of inspired and expired air with the same normal values of temperature, pressure, and relative humidity as those of the respiratory system of a healthy young man on mechanical ventilation. Using several types of materials, a mechanical device was built and regulated using normal values of vital capacity, tidal volume, maximal inspiratory pressure, positive end-expiratory pressure, and gas temperature in the system. The device was submitted to mechanical ventilation for a period of 29.8 min. The changes in the temperature of the air circulating in the system were recorded every two seconds. The statistical analysis of the data collected revealed that the device was approximately as efficient in the conditioning of air as is the respiratory system of a human being. By the study endpoint, we had developed a mechanical device capable of simulating the conditioning of air in the respiratory tract. The device mimics the conditions of temperature, pressure, and relative humidity seen in the respiratory system of healthy individuals.

  5. 40 CFR 63.341 - Definitions and nomenclature.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... given in this section. Add-on air pollution control device means equipment installed in the ventilation... chromium emissions from the tank(s). Air pollution control technique means any method, such as an add-on air pollution control device or a chemical fume suppressant, that is used to reduce chromium emissions...

  6. 40 CFR 63.3981 - What definitions apply to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., activators, accelerators). Add-on control means an air pollution control device, such as a thermal oxidizer or carbon adsorber, that reduces pollution in an air stream by destruction or removal before... directing those emissions into an add-on air pollution control device. Capture efficiency or capture system...

  7. 21 CFR 880.5550 - Alternating pressure air flotation mattress.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... body pressure. The device is used to prevent and treat decubitus ulcers (bed sores). (b) Classification... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Alternating pressure air flotation mattress. 880... Personal Use Therapeutic Devices § 880.5550 Alternating pressure air flotation mattress. (a) Identification...

  8. 21 CFR 880.5550 - Alternating pressure air flotation mattress.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... body pressure. The device is used to prevent and treat decubitus ulcers (bed sores). (b) Classification... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Alternating pressure air flotation mattress. 880... Personal Use Therapeutic Devices § 880.5550 Alternating pressure air flotation mattress. (a) Identification...

  9. 21 CFR 880.5550 - Alternating pressure air flotation mattress.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... body pressure. The device is used to prevent and treat decubitus ulcers (bed sores). (b) Classification... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Alternating pressure air flotation mattress. 880... Personal Use Therapeutic Devices § 880.5550 Alternating pressure air flotation mattress. (a) Identification...

  10. 21 CFR 880.5550 - Alternating pressure air flotation mattress.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... body pressure. The device is used to prevent and treat decubitus ulcers (bed sores). (b) Classification... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Alternating pressure air flotation mattress. 880... Personal Use Therapeutic Devices § 880.5550 Alternating pressure air flotation mattress. (a) Identification...

  11. 21 CFR 880.5550 - Alternating pressure air flotation mattress.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... body pressure. The device is used to prevent and treat decubitus ulcers (bed sores). (b) Classification... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Alternating pressure air flotation mattress. 880... Personal Use Therapeutic Devices § 880.5550 Alternating pressure air flotation mattress. (a) Identification...

  12. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... (f). (2) At a minimum, yard air pressure shall be 60 psi at the end of the consist or block of cars... device. (3) If the air pressure of the yard test device is less than 80 psi, then a brake pipe leakage or...

  13. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... (f). (2) At a minimum, yard air pressure shall be 60 psi at the end of the consist or block of cars... device. (3) If the air pressure of the yard test device is less than 80 psi, then a brake pipe leakage or...

  14. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... (f). (2) At a minimum, yard air pressure shall be 60 psi at the end of the consist or block of cars... device. (3) If the air pressure of the yard test device is less than 80 psi, then a brake pipe leakage or...

  15. 49 CFR 232.217 - Train brake tests conducted using yard air.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... reduction of brake pipe air pressure at the same, or slower, rate as an engineer's brake valve. (b) The yard... (f). (2) At a minimum, yard air pressure shall be 60 psi at the end of the consist or block of cars... device. (3) If the air pressure of the yard test device is less than 80 psi, then a brake pipe leakage or...

  16. Testing an innovative device against airborne Aspergillus contamination.

    PubMed

    Desoubeaux, Guillaume; Bernard, Marie-Charlotte; Gros, Valérie; Sarradin, Pierre; Perrodeau, Elodie; Vecellio, Laurent; Piscopo, Antoine; Chandenier, Jacques; Bernard, Louis

    2014-08-01

    Aspergillus fumigatus is a major airborne nosocomial pathogen that is responsible for severe mycosis in immunocompromised patients. We studied the efficacy of an innovative mobile air-treatment device in eliminating A. fumigatus from the air following experimental massive contamination in a high-security room. Viable mycological particles were isolated from sequential air samples in order to evaluate the device's effectiveness in removing the fungus. The concentration of airborne conidia was reduced by 95% in 18 min. Contamination was reduced below the detection threshold in 29 min, even when the machine was at the lowest airflow setting. In contrast, during spontaneous settling with no air treatment, conidia remained airborne for more than 1 h. This indoor air contamination model provided consistent and reproducible results. Because the air purifier proved to be effective at eliminating a major contaminant, it may prove useful in preventing air-transmitted disease agents. In an experimental space mimicking a hospital room, the AirLyse air purifier, which uses a combination of germicidal ultraviolet C irradiation and titanium photocatalysis, effectively eliminated Aspergillus conidia. Such a mobile device may be useful in routine practice for lowering microbiological air contamination in the rooms of patients at risk. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. 47 CFR 15.101 - Equipment authorization of unintentional radiators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... TV interface device Declaration of Conformity or Certification. Cable system terminal device Declaration of Conformity. Stand-alone cable input selector switch Verification. Class B personal computers... used with Class B personal computers Declaration of Conformity or Certification. 1 Class B personal...

  18. 47 CFR 15.101 - Equipment authorization of unintentional radiators.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... TV interface device Declaration of Conformity or Certification. Cable system terminal device Declaration of Conformity. Stand-alone cable input selector switch Verification. Class B personal computers... used with Class B personal computers Declaration of Conformity or Certification. 1 Class B personal...

  19. 47 CFR 15.101 - Equipment authorization of unintentional radiators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... TV interface device Declaration of Conformity or Certification. Cable system terminal device Declaration of Conformity. Stand-alone cable input selector switch Verification. Class B personal computers... used with Class B personal computers Declaration of Conformity or Certification. 1 Class B personal...

  20. 47 CFR 15.101 - Equipment authorization of unintentional radiators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... TV interface device Declaration of Conformity or Certification. Cable system terminal device Declaration of Conformity. Stand-alone cable input selector switch Verification. Class B personal computers... used with Class B personal computers Declaration of Conformity or Certification. 1 Class B personal...

Top