Science.gov

Sample records for airborne particle concentration

  1. Temporal variations of airborne particles concentration in the Brussels environment.

    PubMed

    Vanderstraeten, P; Lénelle, Y; Meurrens, A; Carati, D; Brenig, L; Offer, Z Y

    2007-09-01

    We report and analyze data on the PM10 fraction of airborne particles measured at five recording stations in the Brussels region from October 2002 till September 2003. These stations are representative of the various activity sectors of the Brussels urban area. The objective was the determination of the origin of the PM10 particles (particles up to 10 mum) that are recorded in that region in order to follow the EU directives concerning tolerance level of airborne particles concentration. In order to evaluate the impacts of local and external factors that inject solid particles in the atmosphere of Brussels we compared concentration data from working and not working (holidays) periods. Moreover, we also compared concentrations from periods of agricultural activity and rest in the Brabant provinces surrounding the Brussels region for various crop types. The results lead to the conclusion that the impact or urban traffic is rather limited while that of the agricultural activities is important. Moreover, there appears a clear-cut distinction between different types of crops. PMID:17180416

  2. Airborne particle concentrations at schools measured at different spatial scales

    NASA Astrophysics Data System (ADS)

    Buonanno, G.; Fuoco, F. C.; Morawska, L.; Stabile, L.

    2013-03-01

    Potential adverse effects on children health may result from school exposure to airborne particles. To address this issue, measurements in terms of particle number concentration, particle size distribution and black carbon (BC) concentrations were performed in three school buildings in Cassino (Italy) and its suburbs, outside and inside of the classrooms during normal occupancy and use. Additional time resolved information was gathered on ventilation condition, classroom activity, and traffic count data around the schools were obtained using a video camera. Across the three investigated school buildings, the outdoor and indoor particle number concentration monitored down to 4 nm and up to 3 μm ranged from 2.8 × 104 part cm-3 to 4.7 × 104 part cm-3 and from 2.0 × 104 part cm-3 to 3.5 × 104 part cm-3, respectively. The total particle concentrations were usually higher outdoors than indoors, because no indoor sources were detected. I/O measured was less than 1 (varying in a relatively narrow range from 0.63 to 0.74), however one school exhibited indoor concentrations higher than outdoor during the morning rush hours. Particle size distribution at the outdoor site showed high particle concentrations in different size ranges, varying during the day; in relation to the starting and finishing of school time two modes were found. BC concentrations were 5 times higher at the urban school compared with the suburban and suburban-to-urban differences were larger than the relative differences of ultrafine particle concentrations.

  3. Measurement of airborne particle concentrations near the Sunset Crater volcano, Arizona.

    PubMed

    Benke, Roland R; Hooper, Donald M; Durham, James S; Bannon, Donald R; Compton, Keith L; Necsoiu, Marius; McGinnis, Ronald N

    2009-02-01

    Direct measurements of airborne particle mass concentrations or mass loads are often used to estimate health effects from the inhalation of resuspended contaminated soil. Airborne particle mass concentrations were measured using a personal sampler under a variety of surface-disturbing activities within different depositional environments at both volcanic and nonvolcanic sites near the Sunset Crater volcano in northern Arizona. Focused field investigations were performed at this analog site to improve the understanding of natural and human-induced processes at Yucca Mountain, Nevada. The level of surface-disturbing activity was found to be the most influential factor affecting the measured airborne particle concentrations, which increased over three orders of magnitude relative to ambient conditions. As the surface-disturbing activity level increased, the particle size distribution and the majority of airborne particle mass shifted from particles with aerodynamic diameters less than 10 mum (0.00039 in) to particles with aerodynamic diameters greater than 10 mum (0.00039 in). Under ambient conditions, above average wind speeds tended to increase airborne particle concentrations. In contrast, stronger winds tended to decrease airborne particle concentrations in the breathing zone during light and heavy surface-disturbing conditions. A slight increase in the average airborne particle concentration during ambient conditions was found above older nonvolcanic deposits, which tended to be finer grained than the Sunset Crater tephra deposits. An increased airborne particle concentration was realized when walking on an extremely fine-grained deposit, but the sensitivity of airborne particle concentrations to the resuspendible fraction of near-surface grain mass was not conclusive in the field setting when human activities disturbed the bulk of near-surface material. Although the limited sample size precluded detailed statistical analysis, the differences in airborne particle

  4. Concentration and characterization of airborne particles in Tehran's subway system.

    PubMed

    Kamani, Hosein; Hoseini, Mohammad; Seyedsalehi, Mahdi; Mahdavi, Yousef; Jaafari, Jalil; Safari, Gholam Hosein

    2014-06-01

    Particulate matter is an important air pollutant, especially in closed environments like underground subway stations. In this study, a total of 13 elements were determined from PM10 and PM2.5 samples collected at two subway stations (Imam Khomeini and Sadeghiye) in Tehran's subway system. Sampling was conducted in April to August 2011 to measure PM concentrations in platform and adjacent outdoor air of the stations. In the Imam Khomeini station, the average concentrations of PM10 and PM2.5 were 94.4 ± 26.3 and 52.3 ± 16.5 μg m(-3) in the platform and 81.8 ± 22.2 and 35 ± 17.6 μg m(-3) in the outdoor air, respectively. In the Sadeghiye station, mean concentrations of PM10 and PM2.5 were 87.6 ± 23 and 41.3 ± 20.4 μg m(-3) in the platform and 73.9 ± 17.3 and 30 ± 15 μg m(-3), in the outdoor air, respectively. The relative contribution of elemental components in each particle fraction were accounted for 43% (PM10) and 47.7% (PM2.5) in platform of Imam Khomeini station and 15.9% (PM10) and 18.5% (PM2.5) in the outdoor air of this station. Also, at the Sadeghiye station, each fraction accounted for 31.6% (PM10) and 39.8% (PM2.5) in platform and was 11.7% (PM10) and 14.3% (PM2.5) in the outdoor. At the Imam Khomeini station, Fe was the predominant element to represent 32.4 and 36 % of the total mass of PM10 and PM2.5 in the platform and 11.5 and 13.3% in the outdoor, respectively. At the Sadeghiye station, this element represented 22.7 and 29.8% of total mass of PM10 and PM2.5 in the platform and 8.7 and 10.5% in the outdoor air, respectively. Other major crustal elements were 5.8% (PM10) and 5.3% (PM2.5) in the Imam Khomeini station platform and 2.3 and 2.4% in the outdoor air, respectively. The proportion of other minor elements was significantly lower, actually less than 7% in total samples, and V was the minor concentration in total mass of PM10 and PM2.5 in both platform stations. PMID:24573466

  5. Concentrations and Sources of Airborne Particles in a Neonatal Intensive Care Unit.

    PubMed

    Licina, Dusan; Bhangar, Seema; Brooks, Brandon; Baker, Robyn; Firek, Brian; Tang, Xiaochen; Morowitz, Michael J; Banfield, Jillian F; Nazaroff, William W

    2016-01-01

    Premature infants in neonatal intensive care units (NICUs) have underdeveloped immune systems, making them susceptible to adverse health consequences from air pollutant exposure. Little is known about the sources of indoor airborne particles that contribute to the exposure of premature infants in the NICU environment. In this study, we monitored the spatial and temporal variations of airborne particulate matter concentrations along with other indoor environmental parameters and human occupancy. The experiments were conducted over one year in a private-style NICU. The NICU was served by a central heating, ventilation and air-conditioning (HVAC) system equipped with an economizer and a high-efficiency particle filtration system. The following parameters were measured continuously during weekdays with 1-min resolution: particles larger than 0.3 μm resolved into 6 size groups, CO2 level, dry-bulb temperature and relative humidity, and presence or absence of occupants. Altogether, over sixteen periods of a few weeks each, measurements were conducted in rooms occupied with premature infants. In parallel, a second monitoring station was operated in a nearby hallway or at the local nurses' station. The monitoring data suggest a strong link between indoor particle concentrations and human occupancy. Detected particle peaks from occupancy were clearly discernible among larger particles and imperceptible for submicron (0.3-1 μm) particles. The mean indoor particle mass concentrations averaged across the size range 0.3-10 μm during occupied periods was 1.9 μg/m3, approximately 2.5 times the concentration during unoccupied periods (0.8 μg/m3). Contributions of within-room emissions to total PM10 mass in the baby rooms averaged 37-81%. Near-room indoor emissions and outdoor sources contributed 18-59% and 1-5%, respectively. Airborne particle levels in the size range 1-10 μm showed strong dependence on human activities, indicating the importance of indoor

  6. Concentrations and Sources of Airborne Particles in a Neonatal Intensive Care Unit

    PubMed Central

    Licina, Dusan; Bhangar, Seema; Brooks, Brandon; Baker, Robyn; Firek, Brian; Tang, Xiaochen; Morowitz, Michael J.; Banfield, Jillian F.; Nazaroff, William W.

    2016-01-01

    Premature infants in neonatal intensive care units (NICUs) have underdeveloped immune systems, making them susceptible to adverse health consequences from air pollutant exposure. Little is known about the sources of indoor airborne particles that contribute to the exposure of premature infants in the NICU environment. In this study, we monitored the spatial and temporal variations of airborne particulate matter concentrations along with other indoor environmental parameters and human occupancy. The experiments were conducted over one year in a private-style NICU. The NICU was served by a central heating, ventilation and air-conditioning (HVAC) system equipped with an economizer and a high-efficiency particle filtration system. The following parameters were measured continuously during weekdays with 1-min resolution: particles larger than 0.3 μm resolved into 6 size groups, CO2 level, dry-bulb temperature and relative humidity, and presence or absence of occupants. Altogether, over sixteen periods of a few weeks each, measurements were conducted in rooms occupied with premature infants. In parallel, a second monitoring station was operated in a nearby hallway or at the local nurses’ station. The monitoring data suggest a strong link between indoor particle concentrations and human occupancy. Detected particle peaks from occupancy were clearly discernible among larger particles and imperceptible for submicron (0.3–1 μm) particles. The mean indoor particle mass concentrations averaged across the size range 0.3–10 μm during occupied periods was 1.9 μg/m3, approximately 2.5 times the concentration during unoccupied periods (0.8 μg/m3). Contributions of within-room emissions to total PM10 mass in the baby rooms averaged 37–81%. Near-room indoor emissions and outdoor sources contributed 18–59% and 1–5%, respectively. Airborne particle levels in the size range 1–10 μm showed strong dependence on human activities, indicating the importance of indoor

  7. Airborne particle concentration and meteorologic conditions associated with pneumonia incidence in feedlot cattle.

    PubMed

    MacVean, D W; Franzen, D K; Keefe, T J; Bennett, B W

    1986-12-01

    To elucidate the role of air quality on the occurrence of pneumonia in feedlot cattle, the following environmental values were measured at a feedlot: suspended particulates in 5 particle-size fractions, relative humidity, air temperature, and barometric pressure. Pneumonia incidence data were classified by the number of days the cattle had been at the feedlot (days on feed). The concentration of airborne particles, range of temperature, days on feed, and season of the year were associated with incidence of pneumonia in cattle. Pneumonia incidence rates were greatest both within 15 days of arrival at the feedlot and during the fall sampling periods. The incidence of pneumonia in the 16 to 30 days-on-feed group was closely associated with the concentration of particles 2.0 to 3.3 microns in diameter and the range of daily temperature when exposure occurred 15 days before the onset of disease in the fall and 10 days before in the spring. PMID:3800131

  8. Airborne particle concentration and meteorologic conditions associated with pneumonia incidence in feedlot cattle

    SciTech Connect

    MacVean, D.W.; Franzen, D.K.; Keefe, T.J.; Bennett, B.W.

    1986-12-01

    To elucidate the role of air quality on the occurrence of pneumonia in feedlot cattle, the following environmental values were measured at a feedlot: suspended particulates in 5 particle-size fractions, relative humidity, air temperature, and barometric pressure. Pneumonia incidence data were classified by the number of days the cattle had been at the feedlot (days on feed). The concentration of airborne particles, range of temperature, days on feed, and season of the year were associated with incidence of pneumonia in cattle. Pneumonia incidence rates were greatest both within 15 days of arrival at the feedlot and during the fall sampling periods. The incidence of pneumonia in the 16 to 30 days-on-feed group was closely associated with the concentration of particles 2.0 to 3.3 microns in diameter and the range of daily temperature when exposure occurred 15 days before the onset of disease in the fall and 10 days before in the spring.

  9. Relating urban airborne particle concentrations to shipping using carbon based elemental emission ratios

    NASA Astrophysics Data System (ADS)

    Johnson, Graham R.; Juwono, Alamsyah M.; Friend, Adrian J.; Cheung, Hing-Cho; Stelcer, Eduard; Cohen, David; Ayoko, Godwin A.; Morawska, Lidia

    2014-10-01

    This study demonstrates a novel method for testing the hypothesis that variations in primary and secondary particle number concentration (PNC) in urban air are related to residual fuel oil combustion at a coastal port lying 30 km upwind, by examining the correlation between PNC and airborne particle composition signatures chosen for their sensitivity to the elemental contaminants present in residual fuel oil. Residual fuel oil combustion indicators were chosen by comparing the sensitivity of a range of concentration ratios to airborne emissions originating from the port. The most responsive were combinations of vanadium and sulphur concentration ([S], [V]) expressed as ratios with respect to black carbon concentration ([BC]). These correlated significantly with ship activity at the port and with the fraction of time during which the wind blew from the port. The average [V] when the wind was predominantly from the port was 0.52 ng m-3 (87%) higher than the average for all wind directions and 0.83 ng m-3 (280%) higher than that for the lowest vanadium yielding wind direction considered to approximate the natural background. Shipping was found to be the main source of V impacting urban air quality in Brisbane. However, contrary to the stated hypothesis, increases in PNC related measures did not correlate with ship emission indicators or ship traffic. Hence at this site ship emissions were not found to be a major contributor to PNC compared to other fossil fuel combustion sources such as road traffic, airport and refinery emissions.

  10. Concentration, Size Distribution, and Infectivity of Airborne Particles Carrying Swine Viruses

    PubMed Central

    Alonso, Carmen; Raynor, Peter C.; Davies, Peter R.; Torremorell, Montserrat

    2015-01-01

    When pathogens become airborne, they travel associated with particles of different size and composition. Particle size determines the distance across which pathogens can be transported, as well as the site of deposition and the survivability of the pathogen. Despite the importance of this information, the size distribution of particles bearing viruses emitted by infectious animals remains unknown. In this study we characterized the concentration and size distribution of inhalable particles that transport influenza A virus (IAV), porcine reproductive and respiratory syndrome virus (PRRSV), and porcine epidemic diarrhea virus (PEDV) generated by acutely infected pigs and assessed virus viability for each particle size range. Aerosols from experimentally infected pigs were sampled for 24 days using an Andersen cascade impactor able to separate particles by size (ranging from 0.4 to 10 micrometer (μm) in diameter). Air samples collected for the first 9, 20 and the last 3 days of the study were analyzed for IAV, PRRSV and PEDV, respectively, using quantitative reverse transcription polymerase chain reaction (RT-PCR) and quantified as geometric mean copies/m3 within each size range. IAV was detected in all particle size ranges in quantities ranging from 5.5x102 (in particles ranging from 1.1 to 2.1μm) to 4.3x105 RNA copies/m3 in the largest particles (9.0–10.0μm). PRRSV was detected in all size ranges except particles between 0.7 and 2.1μm in quantities ranging from 6x102 (0.4–0.7μm) to 5.1x104 RNA copies/m3 (9.0–10.0μm). PEDV, an enteric virus, was detected in all particle sizes and in higher quantities than IAV and PRRSV (p < 0.0001) ranging from 1.3x106 (0.4–0.7μm) to 3.5x108 RNA copies/m3 (9.0–10.0μm). Infectious status was demonstrated for the 3 viruses, and in the case of IAV and PRRSV, viruses were isolated from particles larger than 2.1μm. In summary, our results indicated that airborne PEDV, IAV and PRRSV can be found in a wide range of

  11. Mutagenicity of airborne particles.

    PubMed

    Chrisp, C E; Fisher, G L

    1980-09-01

    The physical and chemical properties of airborne particles are important for the interpretation of their potential biologic significance as genotoxic hazards. For polydisperse particle size distributions, the smallest, most respirable particles are generally the most mutagenic. Particulate collection for testing purposes should be designed to reduce artifact formation and allow condensation of mutagenic compounds. Other critical factors such as UV irradiation, wind direction, chemical reactivity, humidity, sample storage, and temperature of combustion are important. Application of chemical extraction methods and subsequent class fractionation techniques influence the observed mutagenic activity. Particles from urban air, coal fly ash, automobile and diesel exhaust, agricultural burning and welding fumes contain primarily direct-acting mutagens. Cigarette smoke condensate, smoke from charred meat and protein pyrolysates, kerosene soot and cigarette smoke condensates contain primarily mutagens which require metabolic activation. Fractionation coupled with mutagenicity testing indicates that the most potent mutagens are found in the acidic fractions of urban air, coal fly ash, and automobile diesel exhaust, whereas mutagens in rice straw smoke and cigarette smoke condensate are found primarily in the basic fractions. The interaction of the many chemical compounds in complex mixtures from airborne particles is likely to be important in determining mutagenic or comutagenic potentials. Because the mode of exposure is generally frequent and prolonged, the presence of tumor-promoting agents in complex mixtures may be a major factor in evaluation of the carcinogenic potential of airborne particles. PMID:7005667

  12. Airborne agent concentration analysis

    DOEpatents

    Gelbard, Fred

    2004-02-03

    A method and system for inferring airborne contaminant concentrations in rooms without contaminant sensors, based on data collected by contaminant sensors in other rooms of a building, using known airflow interconnectivity data. The method solves a least squares problem that minimizes the difference between measured and predicted contaminant sensor concentrations with respect to an unknown contaminant release time. Solutions are constrained to providing non-negative initial contaminant concentrations in all rooms. The method can be used to identify a near-optimal distribution of sensors within the building, when then number of available sensors is less than the total number of rooms. This is achieved by having a system-sensor matrix that is non-singular, and by selecting that distribution which yields the lowest condition number of all the distributions considered. The method can predict one or more contaminant initial release points from the collected data.

  13. Concentration and particle size of airborne toxic algae (brevetoxin) derived from ocean red tide events.

    PubMed

    Cheng, Yung Sung; McDonald, Jacob D; Kracko, Dean; Irvin, C Mitch; Zhou, Yue; Pierce, Richard H; Henry, Michael S; Bourdelaisa, Andrea; Naar, Jerome; Baden, Daniel G

    2005-05-15

    Red tides in the Gulf of Mexico are formed by blooms of the dinoflagellate Karenia brevis, which produces brevetoxins (PbTx). Brevetoxins can be transferred from water to air in the wind-powered whitecapped waves during red tide episodes. Inhalation exposure to marine aerosol containing PbTx causes respiratory problems. A liquid chromatograph/ tandem mass spectrometric method was developed for the detection and quantitation of several PbTxs in ambient samples collected during red tide events. This method was complemented by a previously developed antibody assay that analyzes the entire class of PbTx compounds. The method showed good linearity, accuracy, and reproducibility, allowing quantitation of PbTx compounds in the 10 pg/m3 range. Air concentrations of PbTxs and brevenal for individual samples ranged from 0.01 to 80 ng/m3. The particle size showed a single mode with a mass median diameter between 6 and 10 microm, which was consistent for all of the PbTx species that were measured. Our results imply that individual PbTxs were from the same marine aerosol or from marine aerosol that was produced from the same process. The particle size indicated the likelihood of high deposition efficiency in the respiratory tract with the majority of aerosol deposited in the upper airways and small but not insignificant deposition in the lower airways. PMID:15954221

  14. Airborne concentrations of peanut protein.

    PubMed

    Johnson, Rodney M; Barnes, Charles S

    2013-01-01

    Food allergy to peanut is a significant health problem, and there are reported allergic reactions to peanuts despite not eating or having physical contact with peanuts. It is presumed that an allergic reaction may have occurred from inhalation of airborne peanut allergens. The purpose of this study was to detect the possible concentrations of airborne peanut proteins for various preparations and during specific activities. Separate Ara h 1 and Ara h 2 monoclonal enzyme-linked immunosorbent assays and a polyclonal sandwich enzyme immunoassay for peanuts were used to detect the amount of airborne peanut protein collected using a Spincon Omni 3000 air collector (Sceptor Industries, Inc., Kansas City, MO) under different peanut preparation methods and situations. Air samples were measured for multiple peanut preparations and scenarios. Detectable amounts of airborne peanut protein were measured using a whole peanut immunoassay when removing the shells of roasted peanut. No airborne peanut allergen (Ara h 1 or Ara h 2) or whole peanut protein above the LLD was measured in any of the other peanut preparation collections. Ara h 1, Ara h 2, and polyclonal peanut proteins were detected from water used to boil peanuts. Small amounts of airborne peanut protein were detected in the scenario of removing shells from roasted peanuts; however, Ara h 1 and Ara h 2 proteins were unable to be consistently detected. Although airborne peanut proteins were detected, the concentration of airborne peanut protein that is necessary to elicit a clinical allergic reaction is unknown. PMID:23406937

  15. Summertime ozone and airborne particle concentrations measured on the Juneau Icefield (58°N)

    NASA Astrophysics Data System (ADS)

    Fry, J.; Katz, J. D.; Redell, K.; Dittrich, T.

    2010-12-01

    The Juneau Icefield Research Program has facilitated long-term research on the remote subarctic and mountain environment since 1946. In summer 2010, a pilot air quality study was conducted at Camp 18 on the Juneau Icefield (58°36'N 134°30'W). Ozone mixing ratio and aerosol particle size distribution were measured on a remote glacier plateau, with coincident monitoring of wind speed and direction from August 4-11, 2010. Correlations between these air pollution indicators and airmass source direction are explored to address the broader question of long-range transport of pollution.

  16. The use of an experimental room for monitoring of airborne concentrations of microorganisms, glass fibers, and total particles

    SciTech Connect

    Buttner, M.P.; Stetzenbach, L.D.

    1996-12-31

    An experimental room was used as a microcosm for studies of airborne particles and microorganisms in indoor environments. The interior of the room measures 4 by 4 by 2.2 m high and has a hardwood floor and the walls and ceiling are sheetrocked and coated with interior latex paint. Exterior walls are 11.4-cm thick plywood panels consisting of two outer sections of plywood insulated with fiber glass batts. The ceiling is of similar construction with 17.1-cm thick panels. Attached to the room entrance is an anteroom equipped with a HEPA-filtered air shower to reduce mixing of air resulting from entering and exiting during experiments. The room is equipped with a computer-controlled heating, ventilation, and cooling system. Temperature, relative humidity, air flow, and room pressure can be continuously monitored by probes located in the room and air handling system components. Several research projects have been conducted using this room including monitoring the potential for airborne glass fibers released from rigid fibrous ductboard, comparisons of commercially available samplers for monitoring of airborne fungal spores, and a study on the efficacy of vacuum bags to minimize dispersal of particles, including fungal spores from fungal-contaminated carpet. During studies designed to monitor airborne fiberglass, air samples were taken in the room serviced by new rigid fibrous glass ductwork, and the results were compared to those obtained in the room with bare metal ductwork installed. Monitoring of airborne fungal spores using the Andersen six-stage sampler, the high flow Spiral Biotech sampler, the Biotest RCS Plus sampler, and the Burkard spore trap sampler was performed following the release of Penicillium spores into the room through the supply register. Dispersal of carpet-associated particles and fungal spores was measured after vacuuming using conventional cellulose vacuum bags in comparison to recently developed bags.

  17. Experimental study of the response functions of direct-reading instruments measuring surface-area concentration of airborne nanostructured particles

    NASA Astrophysics Data System (ADS)

    Bau, Sébastien; Witschger, Olivier; Gensdarmes, François; Thomas, Dominique

    2009-05-01

    An increasing number of experimental and theoretical studies focus on airborne nanoparticles (NP) in relation with many aspects of risk assessment to move forward our understanding of the hazards, the actual exposures in the workplace, and the limits of engineering controls and personal protective equipment with regard to NP. As a consequence, generating airborne NP with controlled properties constitutes an important challenge. In parallel, toxicological studies have been carried out, and most of them support the concept that surface-area could be a relevant metric for characterizing exposure to airborne NP [1]. To provide NP surface-area concentration measurements, some direct-reading instruments have been designed, based on attachment rate of unipolar ions to NP by diffusion. However, very few information is available concerning the performances of these instruments and the parameters that could affect their responses. In this context, our work aims at characterizing the actual available instruments providing airborne NP surface-area concentration. The instruments (a- LQ1-DC, Matter Engineering; b-AeroTrak™ 9000, TSI; c- NSAM, TSI model 3550;) are thought to be relevant for further workplace exposure characterization and monitoring. To achieve our work, an experimental facility (named CAIMAN) was specially designed, built and characterized.

  18. Measurement of airborne concentrations of tire and road wear particles in urban and rural areas of France, Japan, and the United States

    NASA Astrophysics Data System (ADS)

    Panko, Julie M.; Chu, Jennifer; Kreider, Marisa L.; Unice, Ken M.

    2013-06-01

    In addition to industrial facilities, fuel combustion, forest fires and dust erosion, exhaust and non-exhaust vehicle emissions are an important source of ambient air respirable particulate matter (PM10). Non-exhaust vehicle emissions are formed from wear particles of vehicle components such as brakes, clutches, chassis and tires. Although the non-exhaust particles are relatively minor contributors to the overall ambient air particulate load, reliable exposure estimates are few. In this study, a global sampling program was conducted to quantify tire and road wear particles (TRWP) in the ambient air in order to understand potential human exposures and the overall contribution of these particles to the PM10. The sampling was conducted in Europe, the United States and Japan and the sampling locations were selected to represent a variety of settings including both rural and urban core; and within each residential, commercial and recreational receptors. The air samples were analyzed using validated chemical markers for rubber polymer based on a pyrolysis technique. Results indicated that TRWP concentrations in the PM10 fraction were low with averages ranging from 0.05 to 0.70 μg m-3, representing an average PM10 contribution of 0.84%. The TRWP concentration in air was associated with traffic load and population density, but the trend was not statistically significant. Further, significant differences across days were not observed. This study provides a robust dataset to understand potential human exposures to airborne TRWP.

  19. Airborne concentrations of PM(2.5) and diesel exhaust particles on Harlem sidewalks: a community-based pilot study.

    PubMed Central

    Kinney, P L; Aggarwal, M; Northridge, M E; Janssen, N A; Shepard, P

    2000-01-01

    Residents of the dense urban core neighborhoods of New York City (NYC) have expressed increasing concern about the potential human health impacts of diesel vehicle emissions. We measured concentrations of particulate matter [less than/equal to] 2.5 micro in aerodynamic diameter (PM(2.5)) and diesel exhaust particles (DEP) on sidewalks in Harlem, NYC, and tested whether spatial variations in concentrations were related to local diesel traffic density. Eight-hour (1000-1800 hr) air samples for PM(2.5 )and elemental carbon (EC) were collected for 5 days in July 1996 on sidewalks adjacent to four geographically distinct Harlem intersections. Samples were taken using portable monitors worn by study staff. Simultaneous traffic counts for diesel trucks, buses, cars, and pedestrians were carried out at each intersection on [Greater/equal to] 2 of the 5 sampling days. Eight-hour diesel vehicle counts ranged from 61 to 2,467 across the four sites. Mean concentrations of PM(2.5) exhibited only modest site-to-site variation (37-47 microg/m(3)), reflecting the importance of broader regional sources of PM(2.5). In contrast, EC concentrations varied 4-fold across sites (from 1.5 to 6 microg/m(3)), and were associated with bus and truck counts on adjacent streets and, at one site, with the presence of a bus depot. A high correlation (r = 0.95) was observed between EC concentrations measured analytically and a blackness measurement based on PM(2.5) filter reflectance, suggesting the utility of the latter as a surrogate measure of DEP in future community-based studies. These results show that local diesel sources in Harlem create spatial variations in sidewalk concentrations of DEP. The study also demonstrates the feasibility of a new paradigm for community-based research involving full and active partnership between academic scientists and community-based organizations. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 PMID:10706526

  20. Airborne soil organic particles generated by precipitation

    NASA Astrophysics Data System (ADS)

    Wang, Bingbing; Harder, Tristan H.; Kelly, Stephen T.; Piens, Dominique S.; China, Swarup; Kovarik, Libor; Keiluweit, Marco; Arey, Bruce W.; Gilles, Mary K.; Laskin, Alexander

    2016-06-01

    Airborne organic particles play a critical role in Earth's climate, public health, air quality, and hydrological and carbon cycles. However, sources and formation mechanisms for semi-solid and solid organic particles are poorly understood and typically neglected in atmospheric models. Laboratory evidence suggests that fine particles can be formed from impaction of mineral surfaces by droplets. Here, we use chemical imaging of particles collected following rain events in the Southern Great Plains, Oklahoma, USA and after experimental irrigation to show that raindrop impaction of soils generates solid organic particles. We find that after rain events, sub-micrometre solid particles, with a chemical composition consistent with soil organic matter, contributed up to 60% of atmospheric particles. Our irrigation experiments indicate that intensive water impaction is sufficient to cause ejection of airborne soil organic particles from the soil surface. Chemical imaging and micro-spectroscopy analysis of particle physico-chemical properties suggest that these particles may have important impacts on cloud formation and efficiently absorb solar radiation. We suggest that raindrop-induced formation of solid organic particles from soils may be a widespread phenomenon in ecosystems such as agricultural systems and grasslands where soils are exposed to strong, episodic precipitation events.

  1. The impact of fireworks on airborne particles

    NASA Astrophysics Data System (ADS)

    Vecchi, Roberta; Bernardoni, Vera; Cricchio, Diana; D'Alessandro, Alessandra; Fermo, Paola; Lucarelli, Franco; Nava, Silvia; Piazzalunga, Andrea; Valli, Gianluigi

    Fireworks are one of the most unusual sources of pollution in atmosphere; although transient, these pollution episodes are responsible for high concentrations of particles (especially metals and organic compounds) and gases. In this paper, results of a study on chemical-physical properties of airborne particles (elements, ions, organic and elemental carbon and particles size distributions) collected during a fireworks episode in Milan (Italy) are reported. Elements typically emitted during pyrotechnic displays increased in 1 h as follows: Sr (120 times), Mg (22 times), Ba (12 times), K (11 times), and Cu (6 times). In our case study, Sr was recognised as the best fireworks tracer because its concentration was very high during the event and lower than, or comparable with, minimum detection limits during other time intervals, suggesting that it was mainly due to pyrotechnic displays. In addition, particles number concentrations increased significantly during the episode (up to 6.7 times in 1 h for the 0.5< d<1 μm size bin). Contributions (e.g. Cu, elemental carbon and nitrogen oxides) to air pollution due to the large traffic volume registered during the same night were also singled out. The original application of Positive Matrix Factorisation and Multiple Linear Regression allowed, as far as we know, here for the first time, the quantification of the fireworks contribution to atmospheric particulate matter (PM) and the resolution of their chemical profile. The contribution of fireworks to the local environment in terms of PM 10 mass, elements and chemical components was assessed with 4-h time resolution. PM 10 mass apportioned by fireworks was up to 33.6 μg m -3 (about 50% of the total PM 10 mass). Major contributors were elemental and organic carbon (2.8 and 8.1 μg m -3, respectively) as well as metals like Mg, K, Sr, Ba, and Cu (0.4, 0.7, 0.07, 0.1, and 0.1 μg m -3, respectively).

  2. Airborne particle PM 2.5/PM 10 mass distribution and particle-bound PAH concentrations near a medical waste incinerator

    NASA Astrophysics Data System (ADS)

    Mao, I.-Fang; Chen, Chien-Nan; Lin, Yi-Chang; Chen, Mei-Lien

    This study attempts to determine the influence of air quality in a residential area near a medical waste incineration plant. Ambient air concentrations of polycyclic aromatic hydrocarbons (PAHs), PM 10 and PM 2.5 (PM—particulate matter) were determined by collecting air samples in areas both upwind and downwind of the plant. The differences in air pollutant levels between the study area and a reference area 11 km away from the plant were evaluated. Dichotomous samplers were used for sampling PM 2.5 and PM 10 from ambient air. Two hundred and twenty samples were obtained from the study area, and 100 samples were taken from a reference area. Samples were weighed by an electronic microbalance and concentrations of PM 2.5 and PM 10 were determined. A HPLC equipped with a fluorescence detector was employed to analyze the concentrations of 15 PAHs compounds adsorbed into PM 2.5 and PM 10. The experimental results indicated that the average concentrations of PM 2.5 and PM 10 were 30.34±17.95 and 36.81±20.45 μg m -3, respectively, in the study area, while the average ratio of PM 2.5/PM 10 was 0.82±0.01. The concentrations of PM 2.5 and PM 10 of the study area located downwind of the incinerator were significantly higher than the study area upwind of the incinerator ( P<0.05). The concentration of PAHs in PM 2.5 in the study area was 2.2 times higher than in the reference area ( P<0.05). Furthermore, the benzo( a)pyrene concentrations in PM 2.5 and PM 10 were 0.11±0.05 ng m -3 and 0.12±0.06 ng m -3 in the study area, respectively. The benzo( a)pyrene concentrations of PM 2.5 and PM 10 in the study area were 7 and 5.3 times higher than in the reference area ( P<0.05), respectively. The study indicated that the air quality of PM 2.5, PM 10 and PAHs had significant contamination by air pollutants emitted from a medical waste incineration factory, representing a public health problem for nearby residences, despite the factory being equipped with a modern air pollution

  3. Focusing particle concentrator with application to ultrafine particles

    DOEpatents

    Hering, Susanne; Lewis, Gregory; Spielman, Steven R.

    2013-06-11

    Technology is presented for the high efficiency concentration of fine and ultrafine airborne particles into a small fraction of the sampled airflow by condensational enlargement, aerodynamic focusing and flow separation. A nozzle concentrator structure including an acceleration nozzle with a flow extraction structure may be coupled to a containment vessel. The containment vessel may include a water condensation growth tube to facilitate the concentration of ultrafine particles. The containment vessel may further include a separate carrier flow introduced at the center of the sampled flow, upstream of the acceleration nozzle of the nozzle concentrator to facilitate the separation of particle and vapor constituents.

  4. Airborne nanoparticle concentrations in the manufacturing of polytetrafluoroethylene (PTFE) apparel.

    PubMed

    Vosburgh, Donna J H; Boysen, Dane A; Oleson, Jacob J; Peters, Thomas M

    2011-03-01

    One form of waterproof, breathable apparel is manufactured from polytetrafluoroethylene (PTFE) membrane laminated fabric using a specific process to seal seams that have been sewn with traditional techniques. The sealing process involves applying waterproof tape to the seam by feeding the seam through two rollers while applying hot air (600 °C). This study addressed the potential for exposure to particulate matter from this sealing process by characterizing airborne particles in a facility that produces more than 1000 lightweight PTFE rain jackets per day. Aerosol concentrations throughout the facility were mapped, breathing zone concentrations were measured, and hoods used to ventilate the seam sealing operation were evaluated. The geometric mean (GM) particle number concentrations were substantially greater in the sewing and sealing areas (67,000 and 188,000 particles cm⁻³)) compared with that measured in the office area (12,100 particles cm⁻³). Respirable mass concentrations were negligible throughout the facility (GM = 0.002 mg m⁻³) in the sewing and sealing areas). The particles exiting the final discharge of the facility's ventilation system were dominated by nanoparticles (number median diameter = 25 nm; geometric standard deviation of 1.39). The breathing zone particle number concentrations of the workers who sealed the sewn seams were highly variable and significantly greater when sealing seams than when conducting other tasks (p < 0.0001). The sealing workers' breathing zone concentrations ranged from 147,000 particles cm⁻³ to 798,000 particles cm⁻³, and their seam responsibility significantly influenced their breathing zone concentrations (p = 0.03). The finding that particle number concentrations were approximately equal outside the hood and inside the local exhaust duct indicated poor effectiveness of the canopy hoods used to ventilate sealing operations. PMID:21347955

  5. Airborne Nanoparticle Concentrations in the Manufacturing of Polytetrafluoroethylene (PTFE) Apparel

    PubMed Central

    Vosburgh, Donna J.H.; Boysen, Dane A.; Oleson, Jacob J.; Peters, Thomas M.

    2016-01-01

    One form of waterproof, breathable apparel is manufactured from polytetrafluoroethylene (PTFE) membrane laminated fabric, using a specific process to seal seams that have been sewn with traditional techniques. The sealing process involves applying waterproof tape to the seam by feeding the seam through two rollers while applying hot air (600°C). This study addressed the potential for exposure to particulate matter from this sealing process, by characterizing airborne particles in a facility that produces over 1,000 lightweight PTFE rain jackets per day. Aerosol concentrations throughout the facility were mapped, breathing zone concentrations were measured, and hoods used to ventilate the seam sealing operation were evaluated. The geometric mean (GM) particle number concentrations were substantially greater in the sewing and sealing areas (67,000 and 188,000 particles cm−3) compared to that measured in the office area (12,100 particles cm−3). Respirable mass concentrations were negligible throughout the facility (GM=0.002 mg m−3 in the sewing and sealing areas). The particles exiting the final discharge of the facility's ventilation system were dominated by nanoparticles (number median diameter = 25 nm; geometric standard deviation of 1.39). The breathing zone particle number concentrations of the workers who sealed the sewn seams were highly variable and significantly greater when sealing seams than when conducting other tasks (p<0.0001). The sealing workers’ breathing zone concentrations ranged from 147,000 particles cm−3 to 798,000 particles cm−3, and their seam responsibility significantly influenced their breathing zone concentrations (p=0.03). The finding that particle number concentrations were approximately equal outside the hood and inside the local exhaust duct indicated poor effectiveness of the canopy hoods used to ventilate sealing operations. PMID:21347955

  6. Effects of particle size and velocity on burial depth of airborne particles in glass fiber filters

    SciTech Connect

    Higby, D.P.

    1984-11-01

    Air sampling for particulate radioactive material involves collecting airborne particles on a filter and then determining the amount of radioactivity collected per unit volume of air drawn through the filter. The amount of radioactivity collected is frequently determined by directly measuring the radiation emitted from the particles collected on the filter. Counting losses caused by the particle becoming buried in the filter matrix may cause concentrations of airborne particulate radioactive materials to be underestimated by as much as 50%. Furthermore, the dose calculation for inhaled radionuclides will also be affected. The present study was designed to evaluate the extent to which particle size and sampling velocity influence burial depth in glass-fiber filters. Aerosols of high-fired /sup 239/PuO/sub 2/ were collected at various sampling velocities on glass-fiber filters. The fraction of alpha counts lost due to burial was determined as the ratio of activity detected by direct alpha count to the quantity determined by photon spectrometry. The results show that burial of airborne particles collected on glass-fiber filters appears to be a weak function of sampling velocity and particle size. Counting losses ranged from 0 to 25%. A correction that assumes losses of 10 to 15% would ensure that the concentration of airborne alpha-emitting radionuclides would not be underestimated when glass-fiber filters are used. 32 references, 21 figures, 11 tables.

  7. [Investigation of Carbonaceous Airborne Particles by Scanning Proton Microprobe].

    PubMed

    Bao, Liang-man; Liu, Jiang-feng; Lei, Qian-tao; Li, Xiao-lin; Zhang, Gui-lin; Li, Yan

    2016-01-15

    Carbonaceous particles are an important component of the atmospheric aerosol particles and important for global climate change, air quality and human health. The PM₁₀ single particles from two environmental monitor locations and seven pollution emission sources were analyzed using scanning proton microprobe (SPM) techniques. The concentration of carbon in individual particles was quantitatively determined by proton non-Rutherford elastic backscattering spectrometry (EBS). The results of this investigation showed that carbonaceous particles were dominant in the pollution sources of coal and oil combustions, diesel busexhaust and automobile exhaust, while inorganic particles were dominant in the sources of steel industry, cement dust and soil dust. Carbonaceous matter was enriched in particles from the city center, while mineral matter was the main component of airborne particles in the industrial area. Elemental mapping of single aerosol particles yielded important information on the chemical reactions of aerosol particles. The micro-PIXE (particle induced X-ray emission) maps of S, Ca and Fe of individual carbonaceous particles showed that sulfuration reaction occurred between SO₂and mineral particles, which increased the sulfur content of particles. PMID:27078933

  8. New Methods for Personal Exposure Monitoring for Airborne Particles.

    PubMed

    Koehler, Kirsten A; Peters, Thomas M

    2015-12-01

    Airborne particles have been associated with a range of adverse cardiopulmonary outcomes, which has driven its monitoring at stationary central sites throughout the world. Individual exposures, however, can differ substantially from concentrations measured at central sites due to spatial variability across a region and sources unique to the individual, such as cooking or cleaning in homes, traffic emissions during commutes, and widely varying sources encountered at work. Personal monitoring with small, battery-powered instruments enables the measurement of an individual's exposure as they go about their daily activities. Personal monitoring can substantially reduce exposure misclassification and improve the power to detect relationships between particulate pollution and adverse health outcomes. By partitioning exposures to known locations and sources, it may be possible to account for variable toxicity of different sources. This review outlines recent advances in the field of personal exposure assessment for particulate pollution. Advances in battery technology have improved the feasibility of 24-h monitoring, providing the ability to more completely attribute exposures to microenvironment (e.g., work, home, commute). New metrics to evaluate the relationship between particulate matter and health are also being considered, including particle number concentration, particle composition measures, and particle oxidative load. Such metrics provide opportunities to develop more precise associations between airborne particles and health and may provide opportunities for more effective regulations. PMID:26385477

  9. New Methods for Personal Exposure Monitoring for Airborne Particles

    PubMed Central

    Koehler, Kirsten A.; Peters, Thomas

    2016-01-01

    Airborne particles have been associated with a range of adverse cardiopulmonary outcomes, which has driven its monitoring at stationary, central sites throughout the world. Individual exposures, however, can differ substantially from concentrations measured at central sites due to spatial variability across a region and sources unique to the individual, such as cooking or cleaning in homes, traffic emissions during commutes, and widely varying sources encountered at work. Personal monitoring with small, battery-powered instruments enables the measurement of an individual’s exposure as they go about their daily activities. Personal monitoring can substantially reduce exposure misclassification and improve the power to detect relationships between particulate pollution and adverse health outcomes. By partitioning exposures to known locations and sources, it may be possible to account for variable toxicity of different sources. This review outlines recent advances in the field of personal exposure assessment for particulate pollution. Advances in battery technology have improved the feasibility of 24-hour monitoring, providing the ability to more completely attribute exposures to microenvironment (e.g., work, home, commute). New metrics to evaluate the relationship between particulate matter and health are also being considered, including particle number concentration, particle composition measures, and particle oxidative load. Such metrics provide opportunities to develop more precise associations between airborne particles and health and may provide opportunities for more effective regulations. PMID:26385477

  10. Evaluation of Airborne Particle Emissions from Commercial Products Containing Carbon Nanotubes

    PubMed Central

    Huang, Guannan; Park, Jae Hong; Cena, Lorenzo G.; Shelton, Betsy L.; Peters, Thomas M.

    2012-01-01

    The emission of the airborne particles from epoxy resin test sticks with different CNT loadings and two commercial products were characterized while sanding with three grit sizes and three disc sander speeds. The total number concentrations, respirable mass concentrations, and particle size number/mass distributions of the emitted particles were measured using a condensation particle counter, an optical particle counter, and a scanning mobility particle sizer. The emitted particles were sampled on a polycarbonate filter and analyzed using electron microscopy. The highest number concentrations (arithmetic mean = 4670 particles/cm3) were produced with coarse sandpaper, 2% (by weight) CNT test sticks and medium disc sander speed, whereas the lowest number concentrations (arithmetic mean = 92 particles/cm3) were produced with medium sandpaper, 2% CNT test sticks and slow disc sander speed. Respirable mass concentrations were highest (arithmetic mean = 1.01 mg/m3) for fine sandpaper, 2% CNT test sticks and medium disc sander speed and lowest (arithmetic mean = 0.20 mg/m3) for medium sandpaper, 0% CNT test sticks and medium disc sander speed. For CNT-epoxy samples, airborne particles were primarily micrometer-sized epoxy cores with CNT protrusions. No free CNTs were observed in airborne samples, except for tests conducted with 4% CNT epoxy. The number concentration, mass concentration, and size distribution of airborne particles generated when products containing CNTs are sanded depends on the conditions of sanding and the characteristics of the material being sanded. PMID:23204914

  11. Effect of airborne particle on SO 2-calcite reaction

    NASA Astrophysics Data System (ADS)

    Böke, Hasan; Göktürk, E. Hale; Caner-Saltık, Emine N.; Demirci, Şahinde

    1999-02-01

    In modern urban atmosphere, sulphur dioxide (SO 2) attacks calcite (CaCO 3) in calcareous stone-producing gypsum (CaSO 4·2H 2O) which forms crust at rain sheltered surfaces and accelerates erosion at areas exposed to rain. The airborne particles collected on stone surfaces have always been considered to enhance the gypsum crust formation and thus it is believed that they should be removed from the surface to decrease the effects of SO 2. In this study, our aim was to investigate this event by carrying out a series of experiments in laboratory using pure calcium carbonate powder to represent calcareous stone. Sodium montmorillonite, activated carbon, ferric oxide, vanadium pentoxide and cupric chloride were mixed in the pure calcium carbonate powder as substitutes of the airborne particles in the polluted atmosphere. The samples have been exposed at nearly 10 ppmv SO 2 concentrations at 90% relative humidity conditions in a reaction chamber for several days. The mineralogical composition of the exposed samples were determined by X-ray diffraction (XRD) analysis and infrared spectrometer (IR). Sulphation reaction products, calcium sulphite hemihydrate, gypsum and unreacted calcite, were determined quantitatively using IR. Exposed samples have also been investigated morphologically using a scanning electron microscope (SEM). Experimental results reveal that calcium sulphite hemihydrate is the main reaction product of the SO 2-calcite reaction. It turns out that airborne particles play an important catalytic role in the oxidation of calcium sulphite hemihydrate into gypsum, although their presence does not very significantly affect the extent of sulphation reaction. This behaviour of airborne particles is explained by the presence of liquid film on the calcium carbonate surface where a series of reactions in the gas-liquid-solid interfaces takes place.

  12. Particle size of airborne mouse crude and defined allergens.

    PubMed

    Sakaguchi, M; Inouye, S; Miyazawa, H; Kamimura, H; Kimura, M; Yamazaki, S

    1989-05-01

    Laboratory animal allergy is a serious occupational diseases of many workers and scientists engaged in animal experimentation. Control measures depend upon characterization of allergens including airborne particles. This study measured the particle size of crude mouse urine and pelt aeroallergens generated in mouse housing rooms and compared them with mouse serum albumin, a defined major allergen. Allergens were detected by specific immunological methods. Most crude and defined allergens (74.5-86.4%) concentrated on a filter with a retention size greater than 7 microns. In distrubed air, allergen concentration increased 1.4 (albumin) to 5 (crude) fold and the proportion of small particles increased from 1.4% in calm air to 4.5% in distrubed air. This information on the generation and size distribution of aeroallergens will be important in the development of effective counter measures. PMID:2724924

  13. Airborne Particle Size Distribution Measurements at USDOE Fernald

    SciTech Connect

    Harley, N.H.; Chittaporn, P.; Heikkinen, M.; Medora, R.; Merrill, R.

    2003-03-27

    There are no long term measurements of the particle size distribution and concentration of airborne radionuclides at any USDOE facility except Fernald. Yet the determinant of lung dose is the particle size, determining the airway and lower lung deposition. Beginning in 2000, continuous (6 to 8 weeks) measurements of the aerosol particle size distribution have been made with a miniature sampler developed under EMSP. Radon gas decays to a chain of four short lived solid radionuclides that attach immediately to the resident atmospheric aerosol. These in turn decay to long lived polonium 210. Alpha emitting polonium is a tracer for any atmospheric aerosol. Six samplers at Fernald and four at QC sites in New Jersey show a difference in both polonium concentration and size distribution with the winter measurements being higher/larger than summer by almost a factor of two at all locations. EMSP USDOE Contract DE FG07 97ER62522.

  14. Inversely tracking indoor airborne particles to locate their release sources

    NASA Astrophysics Data System (ADS)

    Zhang, Tengfei (Tim); Li, Hongzhu; Wang, Shugang

    2012-08-01

    Airborne particles can have numerous adverse effects on human health. Knowing the release locations of airborne particulate sources is helpful in minimizing pollutant exposure. This paper describes a proposal to locate indoor particulate sources by two inverse models: the quasi-reversibility (QR) model and the zone prescription of contaminant sources with the Lagrangian-reversibility (LR) model. The QR model reverses the time marching direction of the Eulerian governing equation and replaces the second-order diffusion term with a fourth-order stabilization term. The zone prescription LR model traces individual particulate motion in a Lagrangian reference frame after reversing the flow field. The particle trajectories are solved backward to the initial release once the conservative forces acting on particles are reversed. The tracked particles are proposed to be placed at the zone boundary of the largest concentration contour within the domain at a given time, which is provided as the initially known information. By connecting all particles at t = 0, a zone is formed that can prescribe the actual contaminant source. This study finds that both models can accurately locate particulate sources released instantaneously at a spot. The QR model performs slightly better than the LR model but is much more computationally demanding.

  15. Spacecraft Maximum Allowable Concentrations for Airborne Contaminants

    NASA Technical Reports Server (NTRS)

    James, John T.

    2008-01-01

    The enclosed table lists official spacecraft maximum allowable concentrations (SMACs), which are guideline values set by the NASA/JSC Toxicology Group in cooperation with the National Research Council Committee on Toxicology (NRCCOT). These values should not be used for situations other than human space flight without careful consideration of the criteria used to set each value. The SMACs take into account a number of unique factors such as the effect of space-flight stress on human physiology, the uniform good health of the astronauts, and the absence of pregnant or very young individuals. Documentation of the values is given in a 5 volume series of books entitled "Spacecraft Maximum Allowable Concentrations for Selected Airborne Contaminants" published by the National Academy Press, Washington, D.C. These books can be viewed electronically at http://books.nap.edu/openbook.php?record_id=9786&page=3. Short-term (1 and 24 hour) SMACs are set to manage accidental releases aboard a spacecraft and permit risk of minor, reversible effects such as mild mucosal irritation. In contrast, the long-term SMACs are set to fully protect healthy crewmembers from adverse effects resulting from continuous exposure to specific air pollutants for up to 1000 days. Crewmembers with allergies or unusual sensitivity to trace pollutants may not be afforded complete protection, even when long-term SMACs are not exceeded. Crewmember exposures involve a mixture of contaminants, each at a specific concentration (C(sub n)). These contaminants could interact to elicit symptoms of toxicity even though individual contaminants do not exceed their respective SMACs. The air quality is considered acceptable when the toxicity index (T(sub grp)) for each toxicological group of compounds is less than 1, where T(sub grp), is calculated as follows: T(sub grp) = C(sub 1)/SMAC(sub 1) + C(sub 2/SMAC(sub 2) + ...+C(sub n)/SMAC(sub n).

  16. Anthropogenic Osmium in Airborne Particles from Woods Hole, Massachusetts, USA

    NASA Astrophysics Data System (ADS)

    Peucker-Ehrenbrink, B.; Sen, I. S.; Geboy, N.

    2012-12-01

    The global geochemical cycle of osmium has been significantly disturbed by the introduction of automobile exhaust catalysts to convert noxious gas emissions into more benign forms. Anthropogenic osmium has been reported in rainwater, snow, and in the urban airborne particles from around the world to reveal global-scale osmium pollution [1, 2]. In this study, we report on the platinum group element (PGE) concentrations and osmium isotope ratios of airborne particles (PM10) collected in Woods Hole, a small coastal town in Massachusetts to better understand inputs of anthropogenic osmium to rural environments. We further investigate the use of osmium isotopes to track sources of airborne particles and support source apportionment studies on a continental scale. The samples used in this study were collected at Woods Hole Oceanographic Institution over one year (2008-2009). From this collection twelve samples for which the backward air mass trajectories have been determined were selected for osmium isotope analyses. Our results show that the osmium and platinum concentrations are an order of magnitude lower when compared to downtown Boston [2]. The average Os, Pt and Ir concentrations are 0.006±0.012, 0.019±0.023, and 0.685±0.634 pg m-3, respectively. The 187Os/188Os of the aerosols range from 0.275 to 0.788. As continental crust is radiogenic (187Os/188Os >1) and PGE ore bodies generally have unradiogenic 187Os/188Os (~0.2), the unradiogenic 187Os/188Os signature of the aerosols indicates anthropogenic contributions. With 95% of the total osmium mobilization on land being attributed to human activities [3], it is clear that human imprint on airborne particles is not restricted to urban centers with high traffic flows, but also affects rural environments. Aerosol particles that have backward air mass trajectories from the Southwest, the densely populated and industrialized Eastern seaboard, are characterized by unradiogenic osmium, while air masses from the North

  17. A new method for determining the sources of airborne particles.

    PubMed

    Oteros, J; García-Mozo, H; Alcázar, P; Belmonte, J; Bermejo, D; Boi, M; Cariñanos, P; Díaz de la Guardia, C; Fernández-González, D; González-Minero, F; Gutiérrez-Bustillo, A M; Moreno-Grau, S; Pérez-Badía, R; Rodríguez-Rajo, F J; Ruíz-Valenzuela, L; Suárez-Pérez, J; Trigo, M M; Domínguez-Vilches, E; Galán, C

    2015-05-15

    Air quality is a major issue for humans owing to the fact that the content of particles in the atmosphere has multiple implications for life quality, ecosystem dynamics and environment. Scientists are therefore particularly interested in discovering the origin of airborne particles. A new method has been developed to model the relationship between the emission surface and the total amount of airborne particles at a given distance, employing olive pollen and olive groves as examples. A third-degree polynomial relationship between the air particles at a particular point and the distance from the source was observed, signifying that the nearest area to a point is not that which is most correlated with its air features. This work allows the origin of airborne particles to be discovered and could be implemented in different disciplines related to atmospheric aerosol, thus providing a new approach with which to discover the dynamics of airborne particles. PMID:25837296

  18. Enumerating Spore-Forming Bacteria Airborne with Particles

    NASA Technical Reports Server (NTRS)

    Lin, Ying; Barengoltz, Jack

    2006-01-01

    A laboratory method has been conceived to enable the enumeration of (1) Cultivable bacteria and bacterial spores that are, variously, airborne by themselves or carried by, parts of, or otherwise associated with, other airborne particles; and (2) Spore-forming bacteria among all of the aforementioned cultivable microbes.

  19. AIRBORNE ASBESTOS CONCENTRATIONS DURING BUFFING OF RESILIENT FLOOR TILE

    EPA Science Inventory

    Although asbestos-containing resilient floor tiles are considered nonfriable, the frictional forces exerted on the tile during routine maintenance operations can generate asbestos-containing structures. tudy was conducted to determine the level of airborne asbestos concentrations...

  20. Airborne particle exposure and extrinsic skin aging.

    PubMed

    Vierkötter, Andrea; Schikowski, Tamara; Ranft, Ulrich; Sugiri, Dorothea; Matsui, Mary; Krämer, Ursula; Krutmann, Jean

    2010-12-01

    For decades, extrinsic skin aging has been known to result from chronic exposure to solar radiation and, more recently, to tobacco smoke. In this study, we have assessed the influence of air pollution on skin aging in 400 Caucasian women aged 70-80 years. Skin aging was clinically assessed by means of SCINEXA (score of intrinsic and extrinsic skin aging), a validated skin aging score. Traffic-related exposure at the place of residence was determined by traffic particle emissions and by estimation of soot in fine dust. Exposure to background particle concentration was determined by measurements of ambient particles at fixed monitoring sites. The impact of air pollution on skin aging was analyzed by linear and logistic regression and adjusted for potential confounding variables. Air pollution exposure was significantly correlated to extrinsic skin aging signs, in particular to pigment spots and less pronounced to wrinkles. An increase in soot (per 0.5 × 10(-5) per m) and particles from traffic (per 475  kg per year and square km) was associated with 20% more pigment spots on forehead and cheeks. Background particle pollution, which was measured in low residential areas of the cities without busy traffic and therefore is not directly attributable to traffic but rather to other sources of particles, was also positively correlated to pigment spots on face. These results indicate that particle pollution might influence skin aging as well. PMID:20664556

  1. Size distribution of airborne particles controls outcome of epidemiological studies.

    PubMed

    Harrison, Roy M; Giorio, Chiara; Beddows, David C S; Dall'Osto, Manuel

    2010-12-15

    Epidemiological studies typically using wide size range mass metrics (e.g. PM(10)) have demonstrated associations between airborne particulate matter and several adverse health outcomes. This approach ignores the fact that mass concentration may not correlate with regional lung dose, unlike the case of trace gases. When using measured particle size distributions as the basis for calculating regional lung dose, PM(10) mass concentration is found to be a good predictor of the mass dose in all regions of the lung, but is far less predictive of the surface area and particle number dose. On the other hand, measurements of particle number do not well predict mass dose, indicating that the chosen particle metric is likely to determine the health outcomes detectable by an epidemiological study. Consequently, epidemiological studies using mass metrics (PM(2.5) and PM(10)) may fail to recognise important health consequences of particulate matter exposure, leading to an underestimate of the public health consequences of particle exposure. PMID:21109288

  2. Iridium enrichment in airborne particles from kilauea volcano: january 1983.

    PubMed

    Zoller, W H; Parrington, J R; Kotra, J M

    1983-12-01

    Airborne particulate matter from the January 1983 eruption of Kilauea volcano was inadvertently collected on air filters at Mauna Loa Observatory at a sampling station used to observe particles in global circulation. Analyses of affected samples revealed unusually large concentrations of selenium, arsenic, indium, gold, and sulfur, as expected for volcanic emissions. Strikingly large concentrations of iridium were also observed, the ratio of iridium to aluminum being 17,000 times its value in Hawaiian basalt. Since iridium enrichments have not previously been observed in volcanic emissions, the results for Kilauea suggest that it is part of an unusual volcanic system which may be fed by magma from the mantle. The iridium enrichment appears to be linked with the high fluorine content of the volcanic gases, which suggests that the iridium is released as a volatile IrF(6). PMID:17747384

  3. Airborne measurements of cloud forming nuclei and aerosol particles at Kennedy Space Center, Florida

    NASA Technical Reports Server (NTRS)

    Radke, L. F.; Langer, G.; Hindman, E. E., II

    1978-01-01

    Results of airborne measurements of the sizes and concentrations of aerosol particles, ice nuclei, and cloud condensation nuclei that were taken at Kennedy Space Center, Florida, are presented along with a detailed description of the instrumentation and measuring capabilities of the University of Washington airborne measuring facility (Douglas B-23). Airborne measurements made at Ft. Collins, Colorado, and Little Rock, Arkansas, during the ferry of the B-23 are presented. The particle concentrations differed significantly between the clean air over Ft. Collins and the hazy air over Little Rock and Kennedy Space Center. The concentrations of cloud condensation nuclei over Kennedy Space Center were typical of polluted eastern seaboard air. Three different instruments were used to measure ice nuclei: one used filters to collect the particles, and the others used optical and acoustical methods to detect ice crystals grown in portable cloud chambers. A comparison of the ice nucleus counts, which are in good agreement, is presented.

  4. Dry deposition of large, airborne particles onto a surrogate surface

    NASA Astrophysics Data System (ADS)

    Kim, Eugene; Kalman, David; Larson, Timothy

    Simultaneous measurements of particle dry deposition flux and airborne number concentration in the open atmosphere were made using three different types of artificially generated particles in the size range 10-100 μm - perlite, diatomaceous earth and glass beads. A combination of gravimetric analysis, automated microscopy and sonic anemometry provided size-resolved estimates of both the inertial and gravitational components of the quasi-laminar layer particle deposition velocity, ( Vd) b, as a function of size. Eddy inertial deposition efficiency ( ηdI) was determined as a function of dimensionless eddy Stokes number (Stk e). In the range 3particles and gases to environmental surfaces. DOE Report PNL-SA-6721, Pacific Northwest Laboratories, Richland, WA), used in several regulatory models, significantly under-predicted (up to seven times) ( Vd) b for large particles ( da>10 μm).

  5. HUMAN INTERINDIVIDUAL VARIABILITY IN SUSCEPTIBILITY TO AIRBORNE PARTICLES

    EPA Science Inventory

    Part of the explanation for the persistent epidemiological findings of associations between mortality and morbidity with relatively modest ambient exposures to airborne particles may be that some people are much more susceptible to particle-induced responses than others. This stu...

  6. Transport of airborne particles within a room.

    PubMed

    Richmond-Bryant, J; Eisner, A D; Brixey, L A; Wiener, R W

    2006-02-01

    The objective of this study is to test a technique used to analyze contaminant transport in the wake of a bluff body under controlled experimental conditions for application to aerosol transport in a complex furnished room. Specifically, the hypothesis tested by our work is that the dispersion of contaminants in a room is related to the turbulence kinetic energy and length scale. This turbulence is, in turn, determined by the size and shape of furnishings within the room and by the ventilation characteristics. This approach was tested for indoor dispersion through computational fluid dynamics simulations and laboratory experiments. In each, 3 mum aerosols were released in a furnished room with varied contaminant release locations (at the inlet vent or under a desk). The realizable k approximately epsilon model was employed in the simulations, followed by a Lagrangian particle trajectory simulation used as input for an in-house FORTRAN code to compute aerosol concentration. For the experiments, concentrations were measured simultaneously at seven locations by laser photometry, and air velocity was measured using laser Doppler velocimetry. The results suggest that turbulent diffusion is a significant factor in contaminant residence time in a furnished room. This procedure was then expanded to develop a simplified correlation between contaminant residence time and the number of enclosing surfaces around a point containing the contaminant. Practical Implications The work presented here provides a methodology for relating local aerosol residence time to properties of room ventilation and furniture arrangement. This technique may be used to assess probable locations of high concentration by knowing only the particle release location, furniture configuration, inlet and outlet locations, and air speeds, which are all observable features. Applications of this method include development of 'rules of thumb' for first responders entering a room where an agent has been released

  7. Modelling airborne concentration and deposition rate of maize pollen

    NASA Astrophysics Data System (ADS)

    Jarosz, Nathalie; Loubet, Benjamin; Huber, Laurent

    2004-10-01

    The introduction of genetically modified (GM) crops has reinforced the need to quantify gene flow from crop to crop. This requires predictive tools which take into account meteorological conditions, canopy structure as well as pollen aerodynamic characteristics. A Lagrangian Stochastic (LS) model, called SMOP-2D (Stochastic Mechanistic model for Pollen dispersion and deposition in 2 Dimensions), is presented. It simulates wind dispersion of pollen by calculating individual pollen trajectories from their emission to their deposition. SMOP-2D was validated using two field experiments where airborne concentration and deposition rate of pollen were measured within and downwind from different sized maize (Zea mays) plots together with micrometeorological measurements. SMOP-2D correctly simulated the shapes of the concentration profiles but generally underestimated the deposition rates in the first 10 m downwind from the source. Potential explanations of this discrepancy are discussed. Incorrect parameterisation of turbulence in the transition from the crop to the surroundings is probably the most likely reason. This demonstrates that LS models for particle transfer need to be coupled with air-flow models under complex terrain conditions.

  8. Continuous flow dielectrophoretic particle concentrator

    DOEpatents

    Cummings, Eric B.

    2007-04-17

    A continuous-flow filter/concentrator for separating and/or concentrating particles in a fluid is disclosed. The filter is a three-port device an inlet port, an filter port and a concentrate port. The filter separates particles into two streams by the ratio of their dielectrophoretic mobility to their electrokinetic, advective, or diffusive mobility if the dominant transport mechanism is electrokinesis, advection, or diffusion, respectively.Also disclosed is a device for separating and/or concentrating particles by dielectrophoretic trapping of the particles.

  9. Current concepts on airborne particles and health

    SciTech Connect

    Mauderly, J.L.

    1994-11-01

    Epidemiological evidence of associations between environmental particulate concentrations and both acute and chronic health effects has grown with numerous recent studies conducted in the US and other countries. An association between short-term changes in particulate levels and acute mortality now seems certain. The association is consistent among studies and coherent among indicators of mortality and morbidity. Effects observed at surprisingly low pollution levels have raised concern for current exposures even in modestly polluted cities. Toxicology did not predict the acute mortality effect, and causal mechanisms are difficult to rationalize. Present data suggest that the fine fraction of particulate pollution is more toxic than larger particles, but the contribution of specific particulate species is poorly understood.

  10. Concentration and size distribution of total airborne microbes in hazy and foggy weather.

    PubMed

    Dong, Lijie; Qi, Jianhua; Shao, Congcong; Zhong, Xi; Gao, Dongmei; Cao, Wanwan; Gao, Jiawei; Bai, Ran; Long, Gaoyuan; Chu, Congcong

    2016-01-15

    Atmospheric bioaerosol particles were collected using a bioaerosol sampler from Oct. 2013 to Aug. 2014 in the coastal region of Qingdao. The total microbes were measured using an epifluorescence microscope after staining with DAPI (4',6-diamidino-2-phenylindole). The concentration of total airborne microbes showed seasonal variation, with the highest value in winter and the lowest in summer. The mean concentration of total microbes was 6.55 × 10(5)Cells/m(3) on non-hazy days. The total microbe concentration increased to 7.09 × 10(5) and 9.00 × 10(5)Cells/m(3) on hazy and foggy days, respectively. The particle sizes of the total microbes presented a bimodal distribution on sunny days, with one peak at 1.1-2.1 μm and another at 4.7-7.0 μm. The size distribution of total microbes showed an increase in the fine fraction on hazy days and an increase in the coarse fraction on foggy days. However, the size distribution became unimodal during a heating period. Spearman correlation analysis showed that temperature and O3 had a significant negative correlation with the airborne microbe concentration, while PM2.5, SO2, NO2, CO and the air quality index (AQI) had significant positive correlations with the airborne microbe concentration during hazy days. The increased number of airborne microbes will affect the air quality on hazy days. PMID:26473703

  11. Transport of airborne particles in straight and curved microchannels

    NASA Astrophysics Data System (ADS)

    Schaap, Allison; Chu, Winnie C.; Stoeber, Boris

    2012-08-01

    The measurement of airborne particles is important for environmental and exposure monitoring. Microfluidic technologies present potential advantages for aerosol monitoring but have been applied very little to the handling of airborne particles. In this paper, we examine the flow focusing and cross-streamline diffusion of aerosols in straight microchannels, and the size-based lateral displacement of aerosols caused by centrifugal forces in a curved channel. We present calculations, simulations, and experimental results verifying the models: measurements of the focusing and diffusion of 0.2 μm and 0.75 μm particles in straight channels and of the size-dependent lateral displacement of particles between 0.2 μm and 2 μm in curved channels are demonstrated and shown to match well with the simulations. We observe lateral dispersion of the particles: particles closer to the top and bottom wall of the channel experience less lateral displacement than particles near the center due to the flow velocity distribution across the channel cross section. These results confirm that the microchannel techniques presented are a viable method for the size-based manipulation of airborne particles.

  12. Ambient airborne-solids concentrations including volcanic ash at Hanford, Washington sampling sites subsequent to the Mount St. Helens eruption

    SciTech Connect

    Sehmel, G.A.

    1981-06-01

    A major eruption of Mount St. Helens, state of Washington, USA, occurred on May 18, 1980. The resulting volcanic ash plume was transported to the east. The Hanford area, northwest of Richland, Washington, was within the southern edge of the fallout plume. Airborne solid concentrations and airborne particle size distributions were measured at two sites in the Hanford area, a southern and northern site. During the initial sampling day (May 19), the average concentration for respirable particles, < 5.5-..mu..m diameter, was 1430-..mu..g/m/sup 3/ at the southern site; the total collection was 2610-..mu..g/m/sup 3/. The respirable content of the total airborne solids was 55%. At both sites average airborne solid concentrations decreased to 10- to 20-..mu..g/m/sup 3/ in December.

  13. Airborne soil organic particles generated by precipitation

    DOE PAGESBeta

    Wang, Bingbing; Harder, Tristan H.; Kelly, Stephen T.; Piens, Dominique S.; China, Swarup; Kovarik, Libor; Keiluweit, Marco; Arey, Bruce W.; Gilles, Mary K.; Laskin, Alexander

    2016-05-02

    Airborne organic particles play a critical role in Earth’s climate1, public health2, air quality3, and hydrological and carbon cycles4. However, sources and formation mechanisms for semi-solid and solid organic particles5 are poorly understood and typically neglected in atmospheric models6. Laboratory evidence suggests that fine particles can be formed from impaction of mineral surfaces by droplets7. Here, we use chemical imaging of particles collected following rain events in the Southern Great Plains, Oklahoma, USA and after experimental irrigation to show that raindrop impaction of soils generates solid organic particles. We find that after rain events, sub-micrometre solid particles, with a chemicalmore » composition consistent with soil organic matter, contributed up to 60% of atmospheric particles. Our irrigation experiments indicate that intensive water impaction is sufficient to cause ejection of airborne soil organic particles from the soil surface. Chemical imaging and micro-spectroscopy analysis of particle physico-chemical properties suggest that these particles may have important impacts on cloud formation and efficiently absorb solar radiation. Lastly, we suggest that raindrop-induced formation of solid organic particles from soils may be a widespread phenomenon in ecosystems such as agricultural systems and grasslands where soils are exposed to strong, episodic precipitation events8.« less

  14. A Micro Aerosol Sensor for the Measurement of Airborne Ultrafine Particles

    PubMed Central

    Zhang, Chao; Zhu, Rong; Yang, Wenming

    2016-01-01

    Particle number concentration and particle size are the two key parameters used to characterize exposure to airborne nanoparticles or ultrafine particles that have attracted the most attention. This paper proposes a simple micro aerosol sensor for detecting the number concentration and particle size of ultrafine particles with diameters from 50 to 253 nm based on electrical diffusion charging. The sensor is composed of a micro channel and a couple of planar electrodes printed on two circuit boards assembled in parallel, which thus integrate charging, precipitating and measurement elements into one chip, the overall size of which is 98 × 38 × 25 mm3. The experiment results demonstrate that the sensor is useful for measuring monodisperse aerosol particles with number concentrations from 300 to 2.5 × 104 /cm3 and particle sizes from 50 to 253 nm. The aerosol sensor has a simple structure and small size, which is favorable for use in handheld devices. PMID:26999156

  15. A Micro Aerosol Sensor for the Measurement of Airborne Ultrafine Particles.

    PubMed

    Zhang, Chao; Zhu, Rong; Yang, Wenming

    2016-01-01

    Particle number concentration and particle size are the two key parameters used to characterize exposure to airborne nanoparticles or ultrafine particles that have attracted the most attention. This paper proposes a simple micro aerosol sensor for detecting the number concentration and particle size of ultrafine particles with diameters from 50 to 253 nm based on electrical diffusion charging. The sensor is composed of a micro channel and a couple of planar electrodes printed on two circuit boards assembled in parallel, which thus integrate charging, precipitating and measurement elements into one chip, the overall size of which is 98 × 38 × 25 mm³. The experiment results demonstrate that the sensor is useful for measuring monodisperse aerosol particles with number concentrations from 300 to 2.5 × 10⁴ /cm³ and particle sizes from 50 to 253 nm. The aerosol sensor has a simple structure and small size, which is favorable for use in handheld devices. PMID:26999156

  16. Acoustic Resonator Optimisation for Airborne Particle Manipulation

    NASA Astrophysics Data System (ADS)

    Devendran, Citsabehsan; Billson, Duncan R.; Hutchins, David A.; Alan, Tuncay; Neild, Adrian

    Advances in micro-electromechanical systems (MEMS) technology and biomedical research necessitate micro-machined manipulators to capture, handle and position delicate micron-sized particles. To this end, a parallel plate acoustic resonator system has been investigated for the purposes of manipulation and entrapment of micron sized particles in air. Numerical and finite element modelling was performed to optimise the design of the layered acoustic resonator. To obtain an optimised resonator design, careful considerations of the effect of thickness and material properties are required. Furthermore, the effect of acoustic attenuation which is dependent on frequency is also considered within this study, leading to an optimum operational frequency range. Finally, experimental results demonstrated good particle levitation and capture of various particle properties and sizes ranging to as small as 14.8 μm.

  17. Methods to assess airborne concentrations of cotton dust.

    PubMed

    Corn, M

    1987-01-01

    Assessment of concentrations of airborne cotton dust in the factory is necessary to determine adherence to applicable Permissible Exposure Limits (PELs) on a day-to-day basis, as well as for investigatory studies of an epidemiological nature. The latter are required on an ongoing basis to determine the adequacy of PELs to prevent disease in the exposed population. A strategy of sampling includes considerations of the numbers of samples to be obtained for statistical validity and the locations of samples. Current practice is to obtain more "personal samples" of exposure wherever possible, but with regard to cotton dust, instrumentation is not available for such sampling. In the U.S., the vertical elutriator is the instrument of choice for determining the concentrations of cotton dust in air. Results are expressed as milligrams of airborne particulate (cotton dust) per cubic meter. PMID:3434562

  18. Ambrosia airborne pollen concentration modelling and evaluation over Europe

    NASA Astrophysics Data System (ADS)

    Hamaoui-Laguel, Lynda; Vautard, Robert; Viovy, Nicolas; Khvorostyanov, Dmitry; Colette, Augustin

    2014-05-01

    Native from North America, Ambrosia artemisiifolia L. (Common Ragweed) is an invasive annual weed introduced in Europe in the mid-nineteenth century. It has a very high spreading potential throughout Europe and releases very allergenic pollen leading to health problems for sensitive persons. Because of its health effects, it is necessary to develop modelling tools to be able to forecast ambrosia air pollen concentration and to inform allergy populations of allergenic threshold exceedance. This study is realised within the framework of the ATOPICA project (https://www.atopica.eu/) which is designed to provide first steps in tools and estimations of the fate of allergies in Europe due to changes in climate, land use and air quality. To calculate and predict airborne concentrations of ambrosia pollen, a chain of models has been built. Models have been developed or adapted for simulating the phenology (PMP phonological modelling platform), inter-annual production (ORCHIDEE vegetation model), release and airborne processes (CHIMERE chemical transport model) of ragweed pollen. Airborne pollens follow processes similar to air quality pollutants in CHIMERE with some adaptations. The detailed methodology, formulations and input data will be presented. A set of simulations has been performed to simulate airborne concentrations of pollens over long time periods on a large European domain. Hindcast simulations (2000 - 2012) driven by ERA-Interim re-analyses are designed to best simulate past periods airborne pollens. The modelled pollen concentrations are calibrated with observations and validated against additional observations. Then, 20-year long historical simulations (1986 - 2005) are carried out using calibrated ambrosia density distribution and climate model-driven weather in order to serve as a control simulation for future scenarios. By comparison with multi-annual observed daily pollen counts we have shown that the model captures well the gross features of the pollen

  19. Real-time airborne particle analyzer

    DOEpatents

    Reilly, Peter T.A.

    2012-10-16

    An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.

  20. Photophoretic trapping of airborne particles using ultraviolet illumination.

    PubMed

    Redding, Brandon; Hill, Steven C; Alexson, Dimitri; Wang, Chuji; Pan, Yong-Le

    2015-02-01

    We demonstrate photophoretic trapping of micron-sized absorbing particles in air using pulsed and continuous-wave (CW) ultraviolet laser illumination at wavelengths of 351 nm and 244 nm. We compared the particle trapping dynamics in two trapping geometries consisting of a hollow optical cone formed by light propagating either with or against gravity. This comparison allowed us to isolate the influence of the photophoretic force from the radiative pressure and the convective forces. We found that the absorbing spherical particles tested experienced a positive photophoretic force, whereas the spatially irregular, non-spherical particles tested experienced a negative photophoretic force. By using two trapping geometries, both spherical and non-spherical absorbing particles could be trapped and held securely in place. The position of the trapped particles exhibited a standard deviation of less than 1 µm over 20 seconds. Moreover, by operating in the UV and deep-UV where the majority of airborne materials are absorptive, the system was able to trap a wide range of particle types. Such a general purpose optical trap could enable on-line characterization of airborne particles when coupled with interrogation techniques such as Raman spectroscopy. PMID:25836215

  1. Airborne endotoxin associated with particles of different sizes and affected by water content in handled straw.

    PubMed

    Madsen, A M; Nielsen, S H

    2010-07-01

    High exposures to endotoxin are observed in environments where organic materials are handled and lower exposures are found in e.g. indoor air. Inhaled endotoxin contributes significantly to the induction of airway inflammation and dysfunction. The size of an inhaled particle influences the deposition in the airways and the following health symptoms. The objective is to characterise the distribution of endotoxin on airborne particles of different sizes in straw storage halls with high exposure and in other environments with lower exposure levels to endotoxin. Furthermore we have studied the influence of water content of handled straw on the size distribution of endotoxin containing particles. Total, inhalable, thoracic and respirable endotoxin and particles have each been quantified in aerosols from boiler rooms and straw storage halls at 24 power plants, including 21 biofuel plants. Inhalable, thoracic and respirable endotoxin have been quantified in aerosols from offices and outdoor air. The endotoxin concentration was higher in airborne thoracic dust than in airborne 'total dust'. The median respirable fraction in the straw storage halls, boiler rooms at biofuel plants, boiler rooms at conventional plants, offices and outdoors was respectively 42%, 9%, 19%, 24% and 34%. Thoracic endotoxin per number of thoracic particles was higher than respirable endotoxin per number of respirable particles at the biofuel plants. In straw storage halls the fraction of endotoxin of respirable size was highest on the days with lowest water content in the received straw. Furthermore the exposures to all endotoxin fractions were highest on days with the lowest water content in the received straw. In conclusion the highest exposures and concentrations of endotoxin occur or tend to occur from thoracic dust. A high variation in endotoxin concentrations and in fractions of respirable or thoracic size is found in the different working areas. This is important in the risk assessment and

  2. Contribution of particle counting in assessment of exposure to airborne microorganisms

    NASA Astrophysics Data System (ADS)

    Parat, Sylvie; Perdrix, Alain; Mann, Sylvie; Baconnier, Pierre

    The aim of the study was to determine the relationship between airborne bacterial concentrations and particle counts measured simultaneously at different sites. Andersen single stage viable particle samplers were used for microbial measurements while a Laser particle counter gave the cumulated counts of particles larger than 0.5 μm diameter. The first phase of the study was performed in two experimental rooms where the basic level of microbial contamination was low. Peaks of concentrations were generated by human activity and both bacterial and particle counts were monitored over 1 h. In the second phase, measurements were run for several days in three different buildings normally occupied. Natural variations of bacterial and particle counts were monitored: microbial measurements were performed each hour while particle counts were started with a 10 min frequency. Statistics revealed strong positive correlations between bacterial and particle counts in four sites out of five. Analyses of covariance used to compare the regression lines obtained in each area showed that except for two natural sites, the regression lines were significantly different, indicating that no absolute relationship can be established between the two parameters. Therefore, particle counting should, of course, not take the place of microorganism measurements, but combining particle counting with bioaerosols measurements may allow detection of rapid variations instantaneously and indicate further microbial measurements. This strategy should improve the assessment of people"s real exposure to airborne microorganisms.

  3. Modeling Airborne Beryllium Concentrations From Open Air Dynamic Testing

    NASA Astrophysics Data System (ADS)

    Becker, N. M.

    2003-12-01

    A heightened awareness of airborne beryllium contamination from industrial activities was reestablished during the late 1980's and early 1990's when it became recognized that Chronic Beryllium Disease (CBD) had not been eradicated, and that the Occupational Health and Safety Administration standards for occupational air exposure to beryllium may not be sufficiently protective. This was in response to the observed CBD increase in multiple industrial settings where beryllium was manufactured and/or machined, thus producing beryllium particulates which are then available for redistribution by airborne transport. Sampling and modeling design activities were expanded at Los Alamos National Laboratory in New Mexico to evaluate potential airborne beryllium exposure to workers who might be exposed during dynamic testing activities associated with nuclear weapons Stockpile Stewardship. Herein is presented the results of multiple types of collected air measurements that were designed to characterize the production and dispersion of beryllium used in components whose performance is evaluated during high explosive detonation at open air firing sites. Data from fallout, high volume air, medium volume air, adhesive film, particle size impactor, and fine-particulate counting techniques will be presented, integrated, and applied in dispersion modeling to assess potential onsite and offsite personal exposures resulting from dynamic testing activities involving beryllium.

  4. Airborne monitoring to distinguish engineered nanomaterials from incidental particles for environmental health and safety.

    PubMed

    Peters, Thomas M; Elzey, Sherrie; Johnson, Ronald; Park, Heaweon; Grassian, Vicki H; Maher, Tabitha; O'Shaughnessy, Patrick

    2009-02-01

    Two methods were used to distinguish airborne engineered nanomaterials from other airborne particles in a facility that produces nano-structured lithium titanate metal oxide powder. The first method involved off-line analysis of filter samples collected with conventional respirable samplers at each of seven locations (six near production processes and one outdoors). Throughout most of the facility and outdoors, respirable mass concentrations were low (<0.050 mg/m(3)) and were attributed to particles other than the nanomaterial (<10% by mass titanium determined with inductively coupled plasma atomic emission spectrometry). In contrast, in a single area with extensive material handling, mass concentrations were greatest (0.118 mg m(-3)) and contained up to 39% +/- 11% lithium titanium, indicating the presence of airborne nanomaterial. Analysis of the filter samples collected in this area by transmission electron microscope and scanning electron microscope revealed that the airborne nanomaterial was associated only with spherical aggregates (clusters of fused 10-80 nm nanoparticles) that were larger than 200 nm. This analysis also showed that nanoparticles in this area were the smallest particles of a larger distribution of submicrometer chain agglomerates likely from welding in an adjacent area of the facility. The second method used two, hand-held, direct-reading, battery-operated instruments to obtain a time series of very fine particle number (<300 nm), respirable mass, and total mass concentration, which were then related to activities within the area of extensive material handling. This activity-based monitoring showed that very fine particle number concentrations (<300 nm) had no apparent correlation to worker activities, but that sharp peaks in the respirable and total mass concentration coincided with loading a hopper and replacing nanomaterial collection bags. These findings were consistent with those from the filter-based method in that they demonstrate

  5. Airborne monitoring to distinguish engineered nanomaterials from incidental particles for environmental health and safety

    PubMed Central

    Peters, TM; Elzey, S; Johnson, R; Park, H; Grassian, VH; Maher, T; O'Shaughnessy, P

    2016-01-01

    Two methods were used to distinguish airborne engineered nanomaterials from other airborne particles in a facility that produces nano-structured lithium titanate metal oxide powder. The first method involved off-line analysis of filter samples collected with conventional respirable samplers at each of seven locations (six near production processes and one outdoors). Throughout most of the facility and outdoors, respirable mass concentrations were low (<0.050 mg m−3) and were attributed to particles other than the nanomaterial (<10% by mass titanium determined with inductively coupled plasma atomic emission spectrometry). In contrast, in a single area with extensive material handling, mass concentrations were greatest (0.118 mg m−3) and contained up to 39% +/− 11% lithium titanium, indicating the presence of airborne nanomaterial. Analysis of the filter samples collected in this area by transmission electron microscope and scanning electron microscope revealed that the airborne nanomaterial was associated only with spherical aggregates (clusters of fused 10–80 nm nanoparticles) that were larger than 200 nm. This analysis also showed that nanoparticles in this area were the smallest particles of a larger distribution of submicrometer chain agglomerates likely from welding in an adjacent area of the facility. The second method used two, hand-held, direct-reading, battery-operated instruments to obtain a time series of very fine particle number (<300 nm), respirable mass, and total mass concentration, which were then related to activities within the area of extensive material handling. This activity-based monitoring showed that very fine particle number concentrations (<300 nm) had no apparent correlation to worker activities, but that sharp peaks in the respirable and total mass concentration coincided with loading a hopper and replacing nanomaterial collection bags. These findings were consistent with those from the filter-based method in that they

  6. Discrimination of airborne material particles from light scattering (TAOS) patterns

    NASA Astrophysics Data System (ADS)

    Crosta, Giovanni F.; Pan, Yong-Le; Videen, Gorden; Aptowicz, Kevin B.; Chang, Richard K.

    2013-05-01

    Two-dimensional angle-resolved optical scattering (TAOS) is an experimental method which collects the intensity pattern of monochromatic light scattered by a single, micron-sized airborne particle. In general, the interpretation of these patterns and the retrieval of the particle refractive index, shape or size alone, are difficult problems. The solution proposed herewith relies on a learning machine (LM): rather than identifying airborne particles from their scattering patterns, TAOS patterns themselves are classified. The LM consists of two interacting modules: a feature extraction module and a linear classifier. Feature extraction relies on spectrum enhancement, which includes the discrete cosine Fourier transform and non-linear operations. Linear classification relies on multivariate statistical analysis. Interaction enables supervised training of the LM. The application described in this article aims at discriminating the TAOS patterns of single bacterial spores (Bacillus subtilis) from patterns of atmospheric aerosol and diesel soot particles. The latter are known to interfere with the detection of bacterial spores. Classification has been applied to a data set with more than 3000 TAOS patterns from various materials. Some classification experiments are described, where the size of training sets has been varied as well as many other parameters which control the classifier. By assuming all training and recognition patterns to come from the respective reference materials only, the most satisfactory classification result corresponds to ≍ 20% false negatives from Bacillus subtilis particles and <= 11% false positives from environmental and diesel particles.

  7. Direct Characterization of Airborne Particles Associated with Arsenic-rich Mine Tailings: Particle Size Mineralogy and Texture

    SciTech Connect

    M Corriveau; H Jamieson; M Parsons; J Campbell; A Lanzirotti

    2011-12-31

    Windblown and vehicle-raised dust from unvegetated mine tailings can be a human health risk. Airborne particles from As-rich abandoned Au mine tailings from Nova Scotia, Canada have been characterized in terms of particle size, As concentration, As oxidation state, mineral species and texture. Samples were collected in seven aerodynamically fractionated size ranges (0.5-16 {micro}m) using a cascade impactor deployed at three tailings fields. All three sites are used for recreational activities and off-road vehicles were racing on the tailings at two mines during sample collection. Total concentrations of As in the <8 {micro}m fraction varied from 65 to 1040 ng/m{sup 3} of air as measured by proton-induced X-ray emission (PIXE) analysis. The same samples were analysed by synchrotron-based microfocused X-ray absorption near-edge spectroscopy ({micro}XANES) and X-ray diffraction ({micro}XRD) and found to contain multiple As-bearing mineral species, including Fe-As weathering products. The As species present in the dust were similar to those observed in the near-surface tailings. The action of vehicles on the tailings surface may disaggregate material cemented with Fe arsenate and contribute additional fine-grained As-rich particles to airborne dust. Results from this study can be used to help assess the potential human health risks associated with exposure to airborne particles from mine tailings.

  8. Identifying airborne metal particles sources near an optoelectronic and semiconductor industrial park

    NASA Astrophysics Data System (ADS)

    Chen, Ho-Wen; Chen, Wei-Yea; Chang, Cheng-Nan; Chuang, Yen-Hsun; Lin, Yu-Hao

    2016-06-01

    The recently developed Central Taiwan Science Park (CTSP) in central Taiwan is home to an optoelectronic and semiconductor industrial cluster. Therefore, exploring the elemental compositions and size distributions of airborne particles emitted from the CTSP would help to prevent pollution. This study analyzed size-fractionated metal-rich particle samples collected in upwind and downwind areas of CTSP during Jan. and Oct. 2013 by using micro-orifice uniform deposited impactor (MOUDI). Correlation analysis, hierarchical cluster analysis and particle mass-size distribution analysis are performed to identify the source of metal-rich particle near the CTSP. Analyses of elemental compositions and particle size distributions emitted from the CTSP revealed that the CTSP emits some metals (V, As, In Ga, Cd and Cu) in the ultrafine particles (< 1 μm). The statistical analysis combines with the particle mass-size distribution analysis could provide useful source identification information. In airborne particles with the size of 0.32 μm, Ga could be a useful pollution index for optoelectronic and semiconductor emission in the CTSP. Meanwhile, the ratios of As/Ga concentration at the particle size of 0.32 μm demonstrates that humans near the CTSP would be potentially exposed to GaAs ultrafine particles. That is, metals such as Ga and As and other metals that are not regulated in Taiwan are potentially harmful to human health.

  9. Flow analysis of airborne particles in a hospital operating room

    NASA Astrophysics Data System (ADS)

    Faeghi, Shiva; Lennerts, Kunibert

    2016-06-01

    Preventing airborne infections during a surgery has been always an important issue to deliver effective and high quality medical care to the patient. One of the important sources of infection is particles that are distributed through airborne routes. Factors influencing infection rates caused by airborne particles, among others, are efficient ventilation and the arrangement of surgical facilities inside the operating room. The paper studies the ventilation airflow pattern in an operating room in a hospital located in Tehran, Iran, and seeks to find the efficient configurations with respect to the ventilation system and layout of facilities. This study uses computational fluid dynamics (CFD) and investigates the effects of different inflow velocities for inlets, two pressurization scenarios (equal and excess pressure) and two arrangements of surgical facilities in room while the door is completely open. The results show that system does not perform adequately when the door is open in the operating room under the current conditions, and excess pressure adjustments should be employed to achieve efficient results. The findings of this research can be discussed in the context of design and controlling of the ventilation facilities of operating rooms.

  10. Airborne crystalline silica concentrations at coal-fired power plants associated with coal fly ash.

    PubMed

    Hicks, Jeffrey; Yager, Janice

    2006-08-01

    This study presents measurements of airborne concentrations of respirable crystalline silica in the breathing zone of workers who were anticipated to encounter coal fly ash. Six plants were studied; two were fired with lignite coal, and the remaining four plants used bituminous and subbituminous coals. A total of 108 personal breathing zone respirable dust air samples were collected. Bulk samples were also collected from each plant site and subjected to crystalline silica analysis. Airborne dust particle size analysis was measured where fly ash was routinely encountered. The results from bituminous and subbituminous fired plants revealed that the highest airborne fly ash concentrations are encountered during maintenance activities: 0.008 mg/m3 to 96 mg/m3 (mean of 1.8 mg/m3). This group exceeded the threshold limit values (TLV) in 60% of the air samples. During normal production activities, airborne concentrations of crystalline silica ranged from nondetectable to 0.18 mg/m3 (mean value of 0.048 mg/m3). Air samples collected during these activities exceeded the current and proposed TLVs in approximately 54% and 65% of samples, respectively. Limited amounts of crystalline silica were detected in samples collected from lignite-fired plants, and approximately 20% of these air samples exceeded the current TLV. Particle size analysis in areas where breathing zone air samples were collected revealed mass median diameters typically between 3 microm and 8 microm. Bulk and air samples were analyzed for all of the common crystalline silica polymorphs, and only alpha quartz was detected. As compared with air samples, bulk samples from the same work areas consistently yielded lower relative amounts of quartz. Controls to limit coal fly ash exposures are indicated during some normal plant operations and during episodes of short term, but high concentrations of dust that may be encountered during maintenance activities, especially in areas where ash accumulations are present

  11. Physical and chemical characterization of airborne particles from welding operations in automotive plants.

    PubMed

    Dasch, Jean; D'Arcy, James

    2008-07-01

    Airborne particles were characterized from six welding operations in three automotive plants, including resistance spot welding, metal inert gas (MIG) welding and tungsten inert gas (TIG) welding of aluminum and resistance spot welding, MIG welding and weld-through sealer of galvanized steel. Particle levels were measured throughout the process area to select a sampling location, followed by intensive particle sampling over one working shift. Temporal trends were measured, and particles were collected on filters to characterize their size and chemistry. In all cases, the particles fell into a bimodal size distribution with very large particles >20 mum in diameter, possibly emitted as spatter or metal expulsions, and very small particles about 1 mum in diameter, possibly formed from condensation of vaporized metal. The mass median aerodynamic diameter was about 1 mum, with only about 7% of the particle mass present as ultrafine particles <100 nm. About half the mass of aluminum welding particles could be accounted for by chemical analysis, with the remainder possibly present as oxygen. Predominant species were organic carbon, elemental carbon, iron, and aluminum. More than 80% of the particle mass could be accounted for from steel welding, primarily present as iron, organic carbon, zinc, and copper. Particle concentrations and elemental concentrations were compared with allowable concentrations as recommended by the Occupational Safety and Health Administration and the American Conference of Governmental Industrial Hygienists. In all cases, workplace levels were at least 11 times lower than recommended levels. PMID:18464098

  12. Airborne crystalline silica concentrations at coal-fired power plants associated with coal fly ash

    SciTech Connect

    Hicks, J.; Yager, J.

    2006-08-15

    This study presents measurements of airborne concentrations of respirable crystalline silica in the breathing zone of workers who were anticipated to encounter coal fly ash. Six plants were studied; two were fired with lignite coal, and the remaining four plants used bituminous and subbituminous coals. A total of 108 personal breathing zone respirable dust air samples were collected. Bulk samples were also collected from each plant site and subjected to crystalline silica analysis. Airborne dust particle size analysis was measured where fly ash was routinely encountered. The results from bituminous and subbituminous fired plants revealed that the highest airborne fly ash concentrations are encountered during maintenance activities: 0.008 mg/m{sup 3} to 96 mg/m{sup 3} (mean of 1.8 mg/m{sup 3}). This group exceeded the threshold limit values (TLV) in 60% of the air samples. During normal production activities, airborne concentrations of crystalline silica ranged from nondetectable to 0.18 mg/m{sup 3} (mean value of 0.048 mg/m{sup 3}). Air samples collected during these activities exceeded the current and proposed TLVs in approximately 54% and 65% of samples, respectively. Limited amounts of crystalline silica were detected in samples collected from lignite-fired plants, and approximately 20% of these air samples exceeded the current TLV. Particle size analysis in areas where breathing zone air samples were collected revealed mass median diameters typically between 3 {mu}m and 8 {mu}m. Bulk and air samples were analyzed for all of the common crystalline silica polymorphs, and only alpha quartz was detected.

  13. Predicting emissions of SVOCs from polymeric materials and their interaction with airborne particles.

    PubMed

    Xu, Ying; Little, John C

    2006-01-15

    A model that predicts the emission rate of volatile organic compounds (VOCs) from building materials is extended and used to predict the emission rate of semivolatile organic compounds (SVOCs) from polymeric materials. Reasonable agreement between model predictions and gas-phase di-2-ethylhexyl phthalate (DEHP) concentrations is achieved using data collected in a previous experimental study that measured emissions of DEHP from vinyl flooring in two very different chambers. While emissions of highly volatile VOCs are subject to "internal" control (the material-phase diffusion coefficient), emissions of the very low volatility SVOCs are subject to "external" control (partitioning into the gas phase, the convective mass-transfer coefficient, and adsorption onto interior surfaces). The effect of SVOCs partitioning onto airborne particles is also examined. The DEHP emission rate is increased when the gas-phase concentration is high, and especially when partitioning to the airborne particles is strong. Airborne particles may play an important role in inhalation exposure as well as in transporting SVOCs well beyond the source. Although more rigorous validation is needed, the model should help elucidate the mechanisms governing emissions of phthalate plasticizers, brominated flame retardants, biocides, and other SVOCs from a wide range of building materials and consumer products. PMID:16468389

  14. Characterisation of nano- and micron-sized airborne and collected subway particles, a multi-analytical approach.

    PubMed

    Midander, Klara; Elihn, Karine; Wallén, Anna; Belova, Lyuba; Karlsson, Anna-Karin Borg; Wallinder, Inger Odnevall

    2012-06-15

    Continuous daily measurements of airborne particles were conducted during specific periods at an underground platform within the subway system of the city center of Stockholm, Sweden. Main emphasis was placed on number concentration, particle size distribution, soot content (analyzed as elemental and black carbon) and surface area concentration. Conventional measurements of mass concentrations were conducted in parallel as well as analysis of particle morphology, bulk- and surface composition. In addition, the presence of volatile and semi volatile organic compounds within freshly collected particle fractions of PM(10) and PM(2.5) were investigated and grouped according to functional groups. Similar periodic measurements were conducted at street level for comparison. The investigation clearly demonstrates a large dominance in number concentration of airborne nano-sized particles compared to coarse particles in the subway. Out of a mean particle number concentration of 12000 particles/cm(3) (7500 to 20000 particles/cm(3)), only 190 particles/cm(3) were larger than 250 nm. Soot particles from diesel exhaust, and metal-containing particles, primarily iron, were observed in the subway aerosol. Unique measurements on freshly collected subway particle size fractions of PM(10) and PM(2.5) identified several volatile and semi-volatile organic compounds, the presence of carcinogenic aromatic compounds and traces of flame retardants. This interdisciplinary and multi-analytical investigation aims to provide an improved understanding of reported adverse health effects induced by subway aerosols. PMID:22551935

  15. Spacecraft Maximum Allowable Concentrations for Selected Airborne Contaminants. Volume 3

    NASA Technical Reports Server (NTRS)

    1996-01-01

    This report, prepared by the Committee on Toxicology of the National Research Council's Board on Environmental Studies and Toxicology, is in response to a request from NASA for guidelines to develop spacecraft maximum allowable concentrations (SMACs) for space-station contaminants. SMACs are used to provide guidance on allowable chemical exposures during normal operations and emergency situations. Short-term SMACs refer to concentrations of airborne substances (such as gas, vapor, or aerosol) that will not compromise the performance of specific tasks during emergency conditions lasting up to 24 hours. Long-term SMACs are intended to avoid adverse health effects (either immediate or delayed) and to avoid degradation in crew performance with continuous exposure in a closed space-station environment for as long as 180 days.

  16. Evaluation of cell sorting aerosols and containment by an optical airborne particle counter.

    PubMed

    Xie, Mike; Waring, Michael T

    2015-08-01

    Understanding aerosols produced by cell sorting is critical to biosafety risk assessment and validation of containment efficiency. In this study an Optical Airborne Particle Counter was used to analyze aerosols produced by the BD FACSAria and to assess the effectiveness of its aerosol containment. The suitability of using this device to validate containment was directly compared to the Glo-Germ method put forth by the International Society for Advancement of Cytometry (ISAC) as a standard for testing. It was found that high concentrations of aerosols ranging from 0.3 µm to 10 µm can be detected in failure mode, with most less than 5 µm. In most cases, while numerous aerosols smaller than 5 µm were detected by the Optical Airborne Particle Counter, no Glo-Germ particles were detected, indicating that small aerosols are under-evaluated by the Glo-Germ method. The results demonstrate that the Optical Airborne Particle Counter offers a rapid, economic, and quantitative analysis of cell sorter aerosols and represents an improved method over Glo-Germ for the task of routine validation and monitoring of aerosol containment for cell sorting. PMID:26012776

  17. Airborne particles in Swansea, UK: their collection and characterization.

    PubMed

    Price, Heather; Arthur, Robert; Sexton, Keith; Gregory, Clive; Hoogendoorn, Bastiaan; Matthews, Ian; Jones, Tim; BéruBé, Kelly

    2010-01-01

    Urban air particulate matter (PM) has previously been associated with a variety of adverse health effects. It is now believed that the smallest particles, ultrafine or nanoparticles, are linked to the greatest health effects. The physicochemistry of these particles is likely to provide information regarding their toxicity. Therefore, the aim of this study was to further the understanding of the heterogeneous and changing particle concentrations in urban air, in conjunction with gaining an understanding of the physicochemistry of the particles. A Dekati electrical low-pressure impactor was used to collect the particles and real-time data in a busy traffic corridor in Swansea, Wales, over a period of 10 nonconsecutive weeks. Particle concentrations in the street canyon were analyzed and particle physicochemistries investigated using a variety of techniques. Particle number concentrations were found to vary both diurnally and from day to day in the traffic corridor. Of all particles, the nano to fine size fraction was consistently identified in the highest concentrations (maximum: 140,000 particles cm(-3)). Particle physicochemistry was found to vary as a function of size, with larger particles exhibiting a greater variety of morphologies (and consequently particle types) and associated metals. PMID:20155578

  18. Characterization and Control of Airborne Particles Emitted During Production of Epoxy / Carbon Nanotube Nanocomposites

    PubMed Central

    Cena, Lorenzo G.; Peters, Thomas M.

    2016-01-01

    This work characterized airborne particles that were generated from the weighing of bulk, multi-wall carbon nanotubes (CNTs) and the manual sanding of epoxy test samples reinforced with CNTs. It also evaluated the effectiveness of three local exhaust ventilation (LEV) conditions (no LEV, custom fume hood, and biosafety cabinet) for control of particles generated during sanding of CNT-epoxy nanocomposites. Particle number and respirable mass concentrations were measured using an optical particle counter (OPC) and a condensation particle counter (CPC), and particle morphology was assessed by transmission electron microscopy. The ratios of the geometric mean (GM) concentrations measured during the process to that measured in the background (P/B ratios) were used as indices of the impact of the process and the LEVs on observed concentrations. Processing CNT-epoxy nanocomposites materials released respirable size airborne particles (P/B ratio: weighing = 1.79; sanding = 5.90) but generally no nanoparticles (P/B ratiô1). The particles generated during sanding were predominately micron-sized with protruding CNTs and very different from bulk CNTs that tended to remain in large (>1 μm) tangled clusters. Respirable mass concentrations in the operator’s breathing zone were lower when sanding was performed in the biological safety cabinet (GM = 0.20 μg/m3) compared to those with no LEV (GM = 2.68 μg/m3) or those when sanding was performed inside the fume hood (GM = 21.4 μg/m3; p-value < 0.0001). The poor performance of the custom fume hood used in this study may have been exacerbated by its lack of a front sash and rear baffles and its low face velocity (0.39 m/sec). PMID:21253981

  19. Characterization and control of airborne particles emitted during production of epoxy/carbon nanotube nanocomposites.

    PubMed

    Cena, Lorenzo G; Peters, Thomas M

    2011-02-01

    This work characterized airborne particles generated from the weighing of bulk, multiwall carbon nanotubes (CNTs) and the manual sanding of epoxy test samples reinforced with CNTs. It also evaluated the effectiveness of three local exhaust ventilation (LEV) conditions (no LEV, custom fume hood, and biosafety cabinet) for control of particles generated during sanding of CNT-epoxy nanocomposites. Particle number and respirable mass concentrations were measured using an optical particle counter (OPC) and a condensation particle counter (CPC), and particle morphology was assessed by transmission electron microscopy. The ratios of the geometric mean (GM) concentrations measured during the process to that measured in the background (P/B ratios) were used as indices of the impact of the process and the LEVs on observed concentrations. Processing CNT-epoxy nanocomposites materials released respirable size airborne particles (P/B ratio: weighing = 1.79; sanding = 5.90) but generally no nanoparticles (P/B ratio ∼1). The particles generated during sanding were predominantly micron sized with protruding CNTs and very different from bulk CNTs that tended to remain in large (>1 μm) tangled clusters. Respirable mass concentrations in the operator's breathing zone were lower when sanding was performed in the biological safety cabinet (GM = 0.20 μg/m(3) compared with those with no LEV (GM = 2.68 μg/m(3) or those when sanding was performed inside the fume hood (GM = 21.4 μg/m(3); p-value < 0.0001). The poor performance of the custom fume hood used in this study may have been exacerbated by its lack of a front sash and rear baffles and its low face velocity (0.39 m/sec). PMID:21253981

  20. Total airborne mold particle sampling: evaluation of sample collection, preparation and counting procedures, and collection devices.

    PubMed

    Godish, Diana; Godish, Thad

    2008-02-01

    This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were

  1. System for particle concentration and detection

    DOEpatents

    Morales, Alfredo M.; Whaley, Josh A.; Zimmerman, Mark D.; Renzi, Ronald F.; Tran, Huu M.; Maurer, Scott M.; Munslow, William D.

    2013-03-19

    A new microfluidic system comprising an automated prototype insulator-based dielectrophoresis (iDEP) triggering microfluidic device for pathogen monitoring that can eventually be run outside the laboratory in a real world environment has been used to demonstrate the feasibility of automated trapping and detection of particles. The system broadly comprised an aerosol collector for collecting air-borne particles, an iDEP chip within which to temporarily trap the collected particles and a laser and fluorescence detector with which to induce a fluorescence signal and detect a change in that signal as particles are trapped within the iDEP chip.

  2. Platinum and rhodium concentrations in airborne particulate matter in Germany from 1988 to 1998.

    PubMed

    Zereini, F; Wiseman, C; Alt, F; Messerschmidt, J; Müller, J; Urban, H

    2001-05-15

    Increases in platinum group element (PGE) concentrations in ambient air and dust since the introduction of automotive catalytic converters in 1988 is a cause of concern. Until now, data derived from engine-test bench experiments have provided the basis for the assessment of human health risks associated with PGE exposure. Such experiments have provided valuable information regarding emission data that has been used to estimate ambient exposure concentrations. However, these data are not necessarily representative of typical environmental PGE exposure levels and conditions. Data on measured environmental concentrations is needed to provide a more adequate basis for the assessment of exposure and related risks. Twenty air and airborne-dust samples were provided by the Umweltbundesamt (Federal Environmental Agency, Germany) in the years 1988, 1989, 1992, 1997, and 1998. The samples were collected in Frankfurt/Main and the adjacent city of Offenbach. For this, 11 to 80 m3 of air were filtered over a 24-72 h period using a vacuum. Glass-fiber filters were used to collect samples. Sample platinum and rhodium concentrations were determined using adsorptive voltammetry. Although the number of samples collected in different years is limited, the results indicate a trend toward continuous increases in ambient concentrations of these metals between 1988 and 1998. Specifically, there were 46- and 27-fold increases in Pt and Rh concentrations, respectively. Despite these observed increases, the Pt concentrations measured (i.e., 147 pg/m3 on average, with a maximum of 246 pg/m3 in 1998) fell far below 15,000 pg/m3, which has been suggested as a guidance value (i.e., exposure at this level would be expected to be without appreciable health risk). The results of a particle-size distribution analysis of one sample (8-step impactor) that was collected 150 m away from a street show that approximately 75% of Pt and 95% of Rh occurs in association with large particulate matter of > 2

  3. Characterization of exposures to airborne nanoscale particles during friction stir welding of aluminum.

    PubMed

    Pfefferkorn, Frank E; Bello, Dhimiter; Haddad, Gilbert; Park, Ji-Young; Powell, Maria; McCarthy, Jon; Bunker, Kristin Lee; Fehrenbacher, Axel; Jeon, Yongho; Virji, M Abbas; Gruetzmacher, George; Hoover, Mark D

    2010-07-01

    Friction stir welding (FSW) is considered one of the most significant developments in joining technology over the last half century. Its industrial applications are growing steadily and so are the number of workers using this technology. To date, there are no reports on airborne exposures during FSW. The objective of this study was to investigate possible emissions of nanoscale (<100 nm) and fine (<1 microm) aerosols during FSW of two aluminum alloys in a laboratory setting and characterize their physicochemical composition. Several instruments measured size distributions (5 nm to 20 microm) with 1-s resolution, lung deposited surface areas, and PM(2.5) concentrations at the source and at the breathing zone (BZ). A wide range aerosol sampling system positioned at the BZ collected integrated samples in 12 stages (2 nm to 20 microm) that were analyzed for several metals using inductively coupled plasma mass spectrometry. Airborne aerosol was directly collected onto several transmission electron microscope grids and the morphology and chemical composition of collected particles were characterized extensively. FSW generates high concentrations of ultrafine and submicrometer particles. The size distribution was bimodal, with maxima at approximately 30 and approximately 550 nm. The mean total particle number concentration at the 30 nm peak was relatively stable at approximately 4.0 x 10(5) particles cm(-3), whereas the arithmetic mean counts at the 550 nm peak varied between 1500 and 7200 particles cm(-3), depending on the test conditions. The BZ concentrations were lower than the source concentrations by 10-100 times at their respective peak maxima and showed higher variability. The daylong average metal-specific concentrations were 2.0 (Zn), 1.4 (Al), and 0.24 (Fe) microg m(-3); the estimated average peak concentrations were an order of magnitude higher. Potential for significant exposures to fine and ultrafine aerosols, particularly of Al, Fe, and Zn, during FSW may

  4. Characterization of Exposures to Airborne Nanoscale Particles During Friction Stir Welding of Aluminum

    PubMed Central

    Pfefferkorn, Frank E.; Bello, Dhimiter; Haddad, Gilbert; Park, Ji-Young; Powell, Maria; Mccarthy, Jon; Bunker, Kristin Lee; Fehrenbacher, Axel; Jeon, Yongho; Virji, M. Abbas; Gruetzmacher, George; Hoover, Mark D.

    2010-01-01

    Friction stir welding (FSW) is considered one of the most significant developments in joining technology over the last half century. Its industrial applications are growing steadily and so are the number of workers using this technology. To date, there are no reports on airborne exposures during FSW. The objective of this study was to investigate possible emissions of nanoscale (<100 nm) and fine (<1 μm) aerosols during FSW of two aluminum alloys in a laboratory setting and characterize their physicochemical composition. Several instruments measured size distributions (5 nm to 20 μm) with 1-s resolution, lung deposited surface areas, and PM2.5 concentrations at the source and at the breathing zone (BZ). A wide range aerosol sampling system positioned at the BZ collected integrated samples in 12 stages (2 nm to 20 μm) that were analyzed for several metals using inductively coupled plasma mass spectrometry. Airborne aerosol was directly collected onto several transmission electron microscope grids and the morphology and chemical composition of collected particles were characterized extensively. FSW generates high concentrations of ultrafine and submicrometer particles. The size distribution was bimodal, with maxima at ∼30 and ∼550 nm. The mean total particle number concentration at the 30 nm peak was relatively stable at ∼4.0 × 105 particles cm−3, whereas the arithmetic mean counts at the 550 nm peak varied between 1500 and 7200 particles cm−3, depending on the test conditions. The BZ concentrations were lower than the source concentrations by 10–100 times at their respective peak maxima and showed higher variability. The daylong average metal-specific concentrations were 2.0 (Zn), 1.4 (Al), and 0.24 (Fe) μg m−3; the estimated average peak concentrations were an order of magnitude higher. Potential for significant exposures to fine and ultrafine aerosols, particularly of Al, Fe, and Zn, during FSW may exist, especially in larger scale industrial

  5. Spacecraft Maximum Allowable Concentrations for Selected Airborne Contaminants. Volume 3

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The National Aeronautics and Space Administration (NASA) is aware of the potential toxicological hazards to humans that might be associated with prolonged spacecraft missions. Despite major engineering advances in controlling the atmosphere within spacecraft, some contamination of the air appears inevitable. NASA has measured numerous airborne contaminants during space missions. As the missions increase in duration and complexity, ensuring the health and well-being of astronauts traveling and working in this unique environment becomes increasingly difficult. As part of its efforts to promote safe conditions aboard spacecraft, NASA requested the National Research Council (NRC) to develop guidelines for establishing Spacecraft Maximum Allowable Concentrations (SMAC's) for contaminants, and to review SMAC's for various spacecraft contaminants to determine whether NASA's recommended exposure limits are consistent with the guidelines recommended by the subcommittee. In response to this request, the NRC first developed criteria and methods for preparing SMAC's for spacecraft contaminants, published in its 1992 report Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants. Since then, the Subcommittee on Spacecraft Maximum Allowable Concentrations has been reviewing NASA's documentation of chemical-specific SMAC's as described in the Introduction to this volume. This report is the third volume in the series Spacecraft Maximum Allowable Concentrations for Space Station Contaminants. The first volume was published in 1994 and the second in 1996.

  6. A literature review of concentrations and size distributions of ambient airborne Pb-containing particulate matter

    NASA Astrophysics Data System (ADS)

    Cho, Seung-Hyun; Richmond-Bryant, Jennifer; Thornburg, Jonathan; Portzer, Jeff; Vanderpool, Robert; Cavender, Kevin; Rice, Joann

    2011-09-01

    The final 2008 lead (Pb) national ambient air quality standards (NAAQS) revision maintains Pb in total suspended particulate matter as the indicator. However, the final rule permits the use of low-volume PM 10 (particulate matter sampled with a 50% cut-point of 10 μm) Federal Reference Method (FRM) monitors in lieu of total suspended particulate (TSP) monitors for some non-source-oriented monitoring. PM 10 FRM monitors are known to provide more reliable concentration measurements than TSP samplers because they are omni-directional samplers and so are not biased by wind conditions. However, by design they exclude the upper tail of the particle size distribution. Hence, each monitor produces uncertainties about measured concentrations of Pb-bearing PM. Uncertainties in reported Pb data are also related to spatiotemporal variation of the concentration and size distribution of Pb-bearing PM. Therefore, a comprehensive literature review was performed to summarize the current knowledge regarding the concentration and size distribution of Pb particles in the atmosphere. The objectives of this review were to compile data that could shed light on these uncertainties, to provide insights useful during future Pb NAAQS reviews, and to identify areas where more research is needed. Results of this review indicated that Pb size distribution data are relatively limited and often outdated. Thirty-nine articles were found to have sufficiently detailed information regarding airborne Pb concentrations, study location, sample collection methods, and analytical techniques; only 16 of those papers reported Pb concentration data for multiple size fractions. For the most part, U.S. and European studies from the last forty years illustrate that the largest mode of the size distribution of airborne particle-bound Pb has shifted to larger sizes while airborne Pb concentrations have decreased in urban areas. This shift occurred as tetraethyl Pb additives in gasoline were phased out and

  7. A Lagrangian particle model to predict the airborne spread of foot-and-mouth disease virus

    NASA Astrophysics Data System (ADS)

    Mayer, D.; Reiczigel, J.; Rubel, F.

    Airborne spread of bioaerosols in the boundary layer over a complex terrain is simulated using a Lagrangian particle model, and applied to modelling the airborne spread of foot-and-mouth disease (FMD) virus. Two case studies are made with study domains located in a hilly region in the northwest of the Styrian capital Graz, the second largest town in Austria. Mountainous terrain as well as inhomogeneous and time varying meteorological conditions prevent from application of so far used Gaussian dispersion models, while the proposed model can handle these realistically. In the model, trajectories of several thousands of particles are computed and the distribution of virus concentration near the ground is calculated. This allows to assess risk of infection areas with respect to animal species of interest, such as cattle, swine or sheep. Meteorological input data like wind field and other variables necessary to compute turbulence were taken from the new pre-operational version of the non-hydrostatic numerical weather prediction model LMK ( Lokal-Modell-Kürzestfrist) running at the German weather service DWD ( Deutscher Wetterdienst). The LMK model provides meteorological parameters with a spatial resolution of about 2.8 km. To account for the spatial resolution of 400 m used by the Lagrangian particle model, the initial wind field is interpolated upon the finer grid by a mass consistent interpolation method. Case studies depict a significant influence of local wind systems on the spread of virus. Higher virus concentrations at the upwind side of the hills and marginal concentrations in the lee are well observable, as well as canalization effects by valleys. The study demonstrates that the Lagrangian particle model is an appropriate tool for risk assessment of airborne spread of virus by taking into account the realistic orographic and meteorological conditions.

  8. Spacecraft Maximum Allowable Concentrations for Selected Airborne Contaminants. Volume 2

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The National Aeronautics and Space Administration (NASA) is aware of the potential toxicological hazards to humans that might be associated with prolonged spacecraft missions. Despite major engineering advances in controlling the atmosphere within spacecraft, some contamination of the air appears inevitable. NASA has measured numerous airborne contaminants during space missions. As the missions increase in duration and complexity, ensuring the health and well-being of astronauts traveling and working in this unique environment becomes increasingly difficult. As part of its efforts to promote safe conditions aboard spacecraft, NASA requested the National Research Council (NRC) to develop guidelines for establishing spacecraft maximum allowable concentrations (SMACs) for contaminants, and to review SMACs for various space-craft contaminants to determine whether NASA's recommended exposure limits are consistent with the guidelines recommended by the subcommittee. In response to NASA's request, the NRC organized the Subcommittee on Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants within the Committee On Toxicology (COT). In the first phase of its work, the subcommittee developed the criteria and methods for preparing SMACs for spacecraft contaminants. The subcommittee's report, entitled Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants, was published in 1992. The executive summary of that report is reprinted as Appendix A of this volume. In the second phase of the study, the Subcommittee on Spacecraft Maximum Allowable Concentrations reviewed reports prepared by NASA scientists and contractors recommending SMACs for approximately 35 spacecraft contaminants. The subcommittee sought to determine whether the SMAC reports were consistent with the 1992 guidelines. Appendix B of this volume contains the SMAC reports for 12 chemical contaminants that have been reviewed for

  9. Workplace aerosol mass concentration measurement using optical particle counters.

    PubMed

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  10. CHARACTERIZING THE SOURCES OF HUMAN EXPOSURE TO MUTAGENIC AND CARCINOGENIC CHEMICALS IN AIRBORNE FINE PARTICLES

    EPA Science Inventory

    Personal and ambient exposures to airborne fine particles, polycyclic aromatic hydrocarbons (PAH), and genotoxic activity has been studied in populations in the US, Japan, China, and the Czech Republic. Personal exposure monitors used to collect fine particles were extracted f...

  11. Analysis of airborne pollen concentrations in Zagreb, Croatia, 2002.

    PubMed

    Peternel, Renata; Culig, Josip; Mitić, Bozena; Vukusić, Ivan; Sostar, Zvonimir

    2003-01-01

    Employing the volumetric method by use of a Hirst sampler, a total of 71,286 pollen grains, as many as 94.20% of them allergenic, were recorded in the air samples from the city of Zagreb during the 2002 pollen season. Among identified pollen of 35 plant species/genera/families, 23 were allergenic: Taxus/Juniperus, Alnus sp., Fraxinus sp., Betula sp., Corylus sp., Poaceae, Urticaceae, Artemisia sp., Ambrosia sp., Carpinus sp., Castanea sp., Chenopodiaceae, Salix sp., Populus sp., Ulmus sp., Juglans sp., Quercus sp., Platanus sp., Fagus sp., Plantago sp., Pinus sp., Picea sp. and Abies sp. The pollen of these plants also cause the majority of pollinosis in Europe. Study results and the pollen calendar designed for the 2002 pollen season for the City of Zagreb provide useful data for allergologists to reach an accurate diagnosis. The calendar also provides timely information on airborne pollen types and air concentrations for individuals with pollen hypersensitivity, thus allowing them to adjust their daily activities so as to minimize their contact with allergens and improve their quality of life both at home and at work. PMID:12852741

  12. Airborne fibre and asbestos concentrations in system built schools

    NASA Astrophysics Data System (ADS)

    Burdett, Garry; Cottrell, Steve; Taylor, Catherine

    2009-02-01

    This paper summarises the airborne fibre concentration data measured in system built schools that contained asbestos insulation board (AIB) enclosed in the support columns by a protective steel casing. The particular focus of this work was the CLASP (Consortium of Local Authorities Special Programme) system buildings. A variety of air monitoring tests were carried out to assess the potential for fibres to be released into the classroom. A peak release testing protocol was adopted that involved static sampling, while simulating direct impact disturbances to selected columns. This was carried out before remediation, after sealing gaps and holes in and around the casing visible in the room (i.e. below ceiling level) and additionally round the tops of the columns, which extended into the suspended ceiling void. Simulated and actual measurements of worker exposures were also undertaken, while sealing columns, carrying out cleaning and maintenance work in the ceiling voids. Routine analysis of these air samples was carried out by phase contrast microscopy (PCM) with a limited amount of analytical transmission electron microscopy (TEM) analysis to confirm whether the fibres visible by PCM were asbestos or non-asbestos. The PCM fibre concentrations data from the peak release tests showed that while direct releases of fibres to the room air can occur from gaps and holes in and around the column casings, sealing is an effective way of minimising releases to below the limit of quantification (0.01 f/ml) of the PCM method for some 95% of the tests carried out. Sealing with silicone filler and taping any gaps and seams visible on the column casing in the room, also gave concentrations below the limit of quantification (LOQ) of the PCM method for 95% of the tests carried out. The data available did not show any significant difference between the PCM fibre concentrations in the room air for columns that had or had not been sealed in the ceiling void, as well as in the room

  13. Selection of respiratory protection devices for use in very high concentrations of airborne plutonium.

    PubMed

    Bianconi, C J

    2000-08-01

    This paper focuses on the proper selection of respiratory protection devices for use in very high concentrations of airborne plutonium. Special attention is given to the determination of levels at which airborne plutonium presents a hazard that is immediately dangerous to life or health. PMID:10910403

  14. Size and composition of airborne particles from pavement wear, tires, and traction sanding.

    PubMed

    Kupiainen, Kaarle J; Tervahattu, Heikki; Räisänen, Mika; Mäkelä, Timo; Aurela, Minna; Hillamo, Risto

    2005-02-01

    Mineral matter is an important component of airborne particles in urban areas. In northern cities of the world, mineral matter dominates PM10 during spring because of enhanced road abrasion caused by the use of antiskid methods, including studded tires and traction sanding. In this study, factors that affect formation of abrasion components of springtime road dust were assessed. Effects of traction sanding and tires on concentrations, mass size distribution, and composition of the particles were studied in a test facility. Lowest particle concentrations were observed in tests without traction sanding. The concentrations increased when traction sand was introduced and continued to increase as a function of the amount of aggregate dispersed. Emissions were additionally affected by type of tire, properties of traction sand aggregate, and driving speed. Aggregates with high fragmentation resistance and coarse grain size distribution had the lowest emissions. Over 90% of PM10 was mineral particles. Mineralogy of the dust and source apportionment showed that they originated from both traction sand and pavement aggregates. The remaining portion was mostly carbonaceous and originated from tires and road bitumen. Mass size distributions were dominated by coarse particles. Contribution of fine and submicron size ranges were approximately 15 and 10% in PM10, respectively. PMID:15757329

  15. A comparison study on airborne particles during haze days and non-haze days in Beijing.

    PubMed

    Sun, Zhenquan; Mu, Yujing; Liu, Yanju; Shao, Longyi

    2013-07-01

    Airborne particles in Beijing during haze days and non-haze days were collected by an eleven-stage cascade impactor (MOUDI 110, MSP, USA), and the mass concentrations and water soluble inorganic ions of the size segregated airborne particles were quantitatively analyzed. PM10 concentrations during haze days ranged from 250.5 to 519.4 μgm(-3) which were about 3-8 times greater than those (ranged from 67.6 to 94.0 μgm(-3)) during non-haze days, and PM1.8 concentrations during haze periods were in the range of 117.6-378.6 μgm(-3) which were 3-14 times higher than those (27.0 to 36.8 μgm(-3)) during non-haze days. In comparison with non-haze days, all water soluble inorganic ions investigated in the airborne particles greatly enhanced during haze days. NH₄(+), NO₃(-) and SO₄(2-) were found to be the dominant water soluble inorganic ions, accounting for 91-95% of the total inorganic ions in PM1.8 during haze days, and 73-81% during non-haze days. The size distributions of SO₄(2-), NO₃(-), Cl(-), K(+) and Na(+) exhibited bimodal types, while single mode was found for NH₄(+), Ca(2+) and Mg(2+). Only with exception of Ca(2+) and Mg(2+), all ions were concentrated in fine particles around 0.56-1.0 μm of "droplet mode" during haze days, while 0.32-0.56 μm of "condensation mode" during non-haze days. The extremely high mole ratio (>2) of [NH4(+)]/[SO₄(2-)] during haze days implied that the main form of ammonium in PM1.8 might be (NH4)₂SO₄ and NH₄NO₃. The mass ratio of NO₃(-)/SO₄(2-) was >1 in PM1.8 during haze days and ~1 during non-haze days, indicating that NOx from the vehicle exhaust in Beijing is playing more and more important role on fine particle formation. PMID:23583755

  16. Occupational exposure to airborne particles and other pollutants in an aviation base.

    PubMed

    Buonanno, Giorgio; Bernabei, Manuele; Avino, Pasquale; Stabile, Luca

    2012-11-01

    The occupational exposure to airborne particles and other pollutants in a high performance jet engine airport was investigated. Three spatial scales were considered: i) a downwind receptor site, ii) close to the airstrip, iii) personal monitoring. Particle number, surface area, mass concentrations and distributions were measured as well as inorganic and organic fractions, ionic fractions and Polycyclic Aromatic Hydrocarbons. Particle number distribution measured at a receptor site presents a mode of 80 nm and an average total concentration of 6.5 × 10(3) part. cm(-3); the chemical analysis shows that all the elements may be attributed to long-range transport from the sea. Particle number concentrations in the proximity of the airstrip show short term peaks during the working day mainly related to takeoff, landing and pre-flight operations of jet engines. Personal exposure of workers highlights a median number concentration of 2.5 × 10(4) part. cm(-3) and 1.7 × 10(4) part. cm(-3) for crew chief and hangar operator. PMID:22771354

  17. Concentrations of particulate airborne polycyclic aromatic hydrocarbons and metals collected in Lahore, Pakistan

    NASA Astrophysics Data System (ADS)

    Smith, D. J. T.; Harrison, Roy M.; Luhana, L.; Pio, Casimiro A.; Castro, L. M.; Tariq, Mohammad Nawaz; Hayat, S.; Quraishi, T.

    Hi-vol air sampling equipment was run at three sites (representative of "city", "industrial" and "rural" sampling locations) in Lahore, Pakistan, for over a year. The extraction and quantitative analyses of all Lahore air samples was completed for a suite of metals, various anions, ammonium, elemental and organic carbon, as well as particle-associated polycyclic aromatic hydrocarbons (PAHs). A comparison of Lahore yearly mean pollutant concentrations with those obtained in Birmingham, U.K., shows that airborne metal levels in the Pakistani city are greater by at least one order of magnitude. The concentrations in Lahore obtained from this study are broadly in line with similar studies in Karachi as well as Calcutta and Bombay. Concentrations of particle-associated PAH are also around one order of magnitude higher than in U.K. samples, and, given the difference in ambient temperature, vapour-to-particle ratios of PAH are expected to be far higher in the hotter climate of Lahore. Minerals identified by X-ray diffraction (XRD) in the Lahore air samples were broadly in line with those determined at locations in other parts of the world.

  18. Health effects of airborne exposures from concentrated animal feeding operations.

    PubMed

    Heederik, Dick; Sigsgaard, Torben; Thorne, Peter S; Kline, Joel N; Avery, Rachel; Bønløkke, Jakob H; Chrischilles, Elizabeth A; Dosman, James A; Duchaine, Caroline; Kirkhorn, Steven R; Kulhankova, Katarina; Merchant, James A

    2007-02-01

    Toxic gases, vapors, and particles are emitted from concentrated animal feeding operations (CAFOs) into the general environment. These include ammonia, hydrogen sulfide, carbon dioxide, malodorous vapors, and particles contaminated with a wide range of microorganisms. Little is known about the health risks of exposure to these agents for people living in the surrounding areas. Malodor is one of the predominant concerns, and there is evidence that psychophysiologic changes may occur as a result of exposure to malodorous compounds. There is a paucity of data regarding community adverse health effects related to low-level gas and particulate emissions. Most information comes from studies among workers in CAFO installations. Research over the last decades has shown that microbial exposures, especially endotoxin exposure, are related to deleterious respiratory health effects, of which cross-shift lung function decline and accelerated decline over time are the most pronounced effects. Studies in naïve subjects and workers have shown respiratory inflammatory responses related to the microbial load. This working group, which was part of the Conference on Environmental Health Impacts of Concentrated Animal Feeding Operations: Anticipating Hazards-Searching for Solutions, concluded that there is a great need to evaluate health effects from exposures to the toxic gases, vapors, and particles emitted into the general environment by CAFOs. Research should focus not only on nuisance and odors but also on potential health effects from microbial exposures, concentrating on susceptible subgroups, especially asthmatic children and the elderly, since these exposures have been shown to be related to respiratory health effects among workers in CAFOs. PMID:17384782

  19. Health Effects of Airborne Exposures from Concentrated Animal Feeding Operations

    PubMed Central

    Heederik, Dick; Sigsgaard, Torben; Thorne, Peter S.; Kline, Joel N.; Avery, Rachel; Bønløkke, Jakob H.; Chrischilles, Elizabeth A.; Dosman, James A.; Duchaine, Caroline; Kirkhorn, Steven R.; Kulhankova, Katarina; Merchant, James A.

    2007-01-01

    Toxic gases, vapors, and particles are emitted from concentrated animal feeding operations (CAFOs) into the general environment. These include ammonia, hydrogen sulfide, carbon dioxide, malodorous vapors, and particles contaminated with a wide range of microorganisms. Little is known about the health risks of exposure to these agents for people living in the surrounding areas. Malodor is one of the predominant concerns, and there is evidence that psychophysiologic changes may occur as a result of exposure to malodorous compounds. There is a paucity of data regarding community adverse health effects related to low-level gas and particulate emissions. Most information comes from studies among workers in CAFO installations. Research over the last decades has shown that microbial exposures, especially endotoxin exposure, are related to deleterious respiratory health effects, of which cross-shift lung function decline and accelerated decline over time are the most pronounced effects. Studies in naïve subjects and workers have shown respiratory inflammatory responses related to the microbial load. This working group, which was part of the Conference on Environmental Health Impacts of Concentrated Animal Feeding Operations: Anticipating Hazards—Searching for Solutions, concluded that there is a great need to evaluate health effects from exposures to the toxic gases, vapors, and particles emitted into the general environment by CAFOs. Research should focus not only on nuisance and odors but also on potential health effects from microbial exposures, concentrating on susceptible subgroups, especially asthmatic children and the elderly, since these exposures have been shown to be related to respiratory health effects among workers in CAFOs. PMID:17384782

  20. Characterization of airborne particles generated from metal active gas welding process.

    PubMed

    Guerreiro, C; Gomes, J F; Carvalho, P; Santos, T J G; Miranda, R M; Albuquerque, P

    2014-05-01

    This study is focused on the characterization of particles emitted in the metal active gas welding of carbon steel using mixture of Ar + CO2, and intends to analyze which are the main process parameters that influence the emission itself. It was found that the amount of emitted particles (measured by particle number and alveolar deposited surface area) are clearly dependent on the distance to the welding front and also on the main welding parameters, namely the current intensity and heat input in the welding process. The emission of airborne fine particles seems to increase with the current intensity as fume-formation rate does. When comparing the tested gas mixtures, higher emissions are observed for more oxidant mixtures, that is, mixtures with higher CO2 content, which result in higher arc stability. These mixtures originate higher concentrations of fine particles (as measured by number of particles by cm(3) of air) and higher values of alveolar deposited surface area of particles, thus resulting in a more severe worker's exposure. PMID:24730680

  1. AIRBORNE PARTICLE SIZES AND SOURCES FOUND IN INDOOR AIR

    EPA Science Inventory

    The paper summarizes results of a literature search into the sources, sizes, and concentrations of particles in indoor air, including the various types: plant, animal, mineral, combustion, home/personal care, and radioactive aerosols. This information, presented in a summary figu...

  2. Latex allergens in tire dust and airborne particles.

    PubMed Central

    Miguel, A G; Cass, G R; Weiss, J; Glovsky, M M

    1996-01-01

    The prevalence and severity of latex allergy has increased dramatically in the last 15 years due to exposure to natural rubber products. Although historically this health risk has been elevated in hospital personnel and patients, a recent survey has indicated a significant potential risk for the general population. To obtain a wide-spread source for latex exposure, we have considered tire debris. We have searched for the presence of latex allergens in passenger car and truck tire tread, in debris deposited from the atmosphere near a freeway, and in airborne particulate matter samples representative of the entire year 1993 at two sites in the Los Angeles basin (California). After extraction of the samples with phosphate buffered saline, a modified-ELISA inhibition assay was used to measure relative allergen potency and Western blot analyses were used to identify latex allergens. The inhibition studies with the human IgE latex assay revealed inhibition by the tire tread source samples and ambient freeway dust, as well as by control latex sap and latex glove extracts. Levels of extractable latex allergen per unit of protein extracted were about two orders of magnitude lower for tire tread as compared to latex gloves. Western blot analyses using binding of human IgE from latex-sensitive patients showed a band at 34-36 kDa in all tire and ambient samples. Long Beach and Los Angeles, California, air samples showed four additional bands between 50 and 135 kDa. Alternative Western blot analyses using rabbit IgG raised against latex proteins showed a broad band at 30-50 kDa in all samples, with additional bands in the urban air samples similar to the IgE results. A latex cross-reactive material was identified in mountain cedar. In conclusion, the latex allergens or latex cross-reactive material present in sedimented and airborne particulate material, derived from tire debris, and generated by heavy urban vehicle traffic could be important factors in producing latex allergy

  3. Measured and modelled concentrations and vertical profiles of airborne particulate matter within the boundary layer of a street canyon.

    PubMed

    Colls, J J; Micallef, A

    1999-09-01

    Concentrations and vertical profiles of various fractions of airborne particulate matter (suspended particulate matter (SPM), PM10 and PM2.5) have been measured over the first three metres from ground in a street canyon. Measurements were carried out using automated near real-time apparatus called the Kinetic Sequential Sampling (KSS) system. KSS system is essentially an electronically-controlled lift carrying a real-time particle monitor for sampling air sequentially, at different heights within the breathing zone, which includes all heights within the surface layer of a street canyon at which people may breathe. Data is automatically logged at the different receptor levels, for the determination of the average vertical concentration profile of airborne particulate matter. For measuring the airborne particle concentration, a Grimm Dust Monitor 1.104/5 was used. The recorded data also allows for time series analysis of airborne particulate matter concentration at different heights. Time series data and hourly-average vertical concentration profiles in the boundary layer of the confines of a street are thought to be mainly determined by traffic emissions and traffic associated processes. Hence the measured data were compared with results of a street canyon emission-dispersion model in time and space. This Street Level Air Quality (SLAQ) model employs the plume-box technique and includes modules for simulating vehicle-generated effects such as thermally- and mechanically-generated turbulence and resuspension of road dust. Environmental processes, such as turbulence resulting from surface sensible heat and the formation of sulphate aerosol from sulphur dioxide exhaust emissions, are taken into account. The paper presents an outline description of the measuring technique and model used, and a comparison of the measured and modelled data. PMID:10535122

  4. Temporal Variability of the Bioaerosol Background at a Subway Station: Concentration Level, Size Distribution, and Diversity of Airborne Bacteria

    PubMed Central

    Dybwad, Marius; Skogan, Gunnar

    2014-01-01

    Naturally occurring bioaerosol environments may present a challenge to biological detection-identification-monitoring (BIODIM) systems aiming at rapid and reliable warning of bioterrorism incidents. One way to improve the operational performance of BIODIM systems is to increase our understanding of relevant bioaerosol backgrounds. Subway stations are enclosed public environments which may be regarded as potential bioterrorism targets. This study provides novel information concerning the temporal variability of the concentration level, size distribution, and diversity of airborne bacteria in a Norwegian subway station. Three different air samplers were used during a 72-h sampling campaign in February 2011. The results suggested that the airborne bacterial environment was stable between days and seasons, while the intraday variability was found to be substantial, although often following a consistent diurnal pattern. The bacterial levels ranged from not detected to 103 CFU m−3 and generally showed increased levels during the daytime compared to the nighttime levels, as well as during rush hours compared to non-rush hours. The airborne bacterial levels showed rapid temporal variation (up to 270-fold) on some occasions, both consistent and inconsistent with the diurnal profile. Airborne bacterium-containing particles were distributed between different sizes for particles of >1.1 μm, although ∼50% were between 1.1 and 3.3 μm. Anthropogenic activities (mainly passengers) were demonstrated as major sources of airborne bacteria and predominantly contributed 1.1- to 3.3-μm bacterium-containing particles. Our findings contribute to the development of realistic testing and evaluation schemes for BIODIM equipment by providing information that may be used to simulate operational bioaerosol backgrounds during controlled aerosol chamber-based challenge tests with biological threat agents. PMID:24162566

  5. A Quantitative Dynamic Simulation of Bremia lactucae Airborne Conidia Concentration above a Lettuce Canopy.

    PubMed

    Fall, Mamadou Lamine; Van der Heyden, Hervé; Carisse, Odile

    2016-01-01

    Lettuce downy mildew, caused by the oomycete Bremia lactucae Regel, is a major threat to lettuce production worldwide. Lettuce downy mildew is a polycyclic disease driven by airborne spores. A weather-based dynamic simulation model for B. lactucae airborne spores was developed to simulate the aerobiological characteristics of the pathogen. The model was built using the STELLA platform by following the system dynamics methodology. The model was developed using published equations describing disease subprocesses (e.g., sporulation) and assembled knowledge of the interactions among pathogen, host, and weather. The model was evaluated with four years of independent data by comparing model simulations with observations of hourly and daily airborne spore concentrations. The results show an accurate simulation of the trend and shape of B. lactucae temporal dynamics of airborne spore concentration. The model simulated hourly and daily peaks in airborne spore concentrations. More than 95% of the simulation runs, the daily-simulated airborne conidia concentration was 0 when airborne conidia were not observed. Also, the relationship between the simulated and the observed airborne spores was linear. In more than 94% of the simulation runs, the proportion of the linear variation in the hourly-observed values explained by the variation in the hourly-simulated values was greater than 0.7 in all years except one. Most of the errors came from the deviation from the 1:1 line, and the proportion of errors due to the model bias was low. This model is the only dynamic model developed to mimic the dynamics of airborne inoculum and represents an initial step towards improved lettuce downy mildew understanding, forecasting and management. PMID:26953691

  6. A Quantitative Dynamic Simulation of Bremia lactucae Airborne Conidia Concentration above a Lettuce Canopy

    PubMed Central

    Fall, Mamadou Lamine; Van der Heyden, Hervé; Carisse, Odile

    2016-01-01

    Lettuce downy mildew, caused by the oomycete Bremia lactucae Regel, is a major threat to lettuce production worldwide. Lettuce downy mildew is a polycyclic disease driven by airborne spores. A weather-based dynamic simulation model for B. lactucae airborne spores was developed to simulate the aerobiological characteristics of the pathogen. The model was built using the STELLA platform by following the system dynamics methodology. The model was developed using published equations describing disease subprocesses (e.g., sporulation) and assembled knowledge of the interactions among pathogen, host, and weather. The model was evaluated with four years of independent data by comparing model simulations with observations of hourly and daily airborne spore concentrations. The results show an accurate simulation of the trend and shape of B. lactucae temporal dynamics of airborne spore concentration. The model simulated hourly and daily peaks in airborne spore concentrations. More than 95% of the simulation runs, the daily-simulated airborne conidia concentration was 0 when airborne conidia were not observed. Also, the relationship between the simulated and the observed airborne spores was linear. In more than 94% of the simulation runs, the proportion of the linear variation in the hourly-observed values explained by the variation in the hourly-simulated values was greater than 0.7 in all years except one. Most of the errors came from the deviation from the 1:1 line, and the proportion of errors due to the model bias was low. This model is the only dynamic model developed to mimic the dynamics of airborne inoculum and represents an initial step towards improved lettuce downy mildew understanding, forecasting and management. PMID:26953691

  7. Machine vision based particle size and size distribution determination of airborne dust particles of wood and bark pellets

    SciTech Connect

    Igathinathane, C; Pordesimo, L.O.

    2009-08-01

    Dust management strategies in industrial environment, especially of airborne dust, require quantification and measurement of size and size distribution of the particles. Advanced specialized instruments that measure airborne particle size and size distribution apply indirect methods that involve light scattering, acoustic spectroscopy, and laser diffraction. In this research, we propose a simple and direct method of airborne dust particle dimensional measurement and size distribution analysis using machine vision. The method involves development of a user-coded ImageJ plugin that measures particle length and width and analyzes size distribution of particles based on particle length from high-resolution scan images. Test materials were airborne dust from soft pine wood sawdust pellets and ground pine tree bark pellets. Subsamples prepared by dividing the actual dust using 230 mesh (63 m) sieve were analyzed as well. A flatbed document scanner acquired the digital images of the dust particles. Proper sampling, layout of dust particles in singulated arrangement, good contrast smooth background, high resolution images, and accurate algorithm are essential for reliable analysis. A halo effect around grey-scale images ensured correct threshold limits. The measurement algorithm used Feret s diameter for particle length and pixel-march technique for particle width. Particle size distribution was analyzed in a sieveless manner after grouping particles according to their distinct lengths, and several significant dimensions and parameters of particle size distribution were evaluated. Results of the measurement and analysis were presented in textual and graphical formats. The developed plugin was evaluated to have a dimension measurement accuracy in excess of 98.9% and a computer speed of analysis of <8 s/image. Arithmetic mean length of actual wood and bark pellets airborne dust particles were 0.1138 0.0123 and 0.1181 0.0149 mm, respectively. The airborne dust particles of

  8. Self-refreshing characteristics of an airborne particle sensor using a bridged paddle oscillator

    NASA Astrophysics Data System (ADS)

    Choi, Eunsuk; Lee, Seung-Beck; Park, Bonghyun; Sul, Onejae

    2016-05-01

    We report on the self-refreshing characteristics of a micromachined airborne particle sensor. The sensor consists of a bridge-type beam having an oscillating paddle-type particle collector at its center. When a positive potential is applied to the paddle, the sensor is able to attract and collect negatively charged airborne particles while oscillating close to its resonant frequency and thereby measure their density from the change in the oscillating phase at ˜10 pg resolution. When the applied potential is removed, the collected particles are detached from the sensor due to momentum transfer from the oscillating paddle, thus demonstrating a self-refreshing capability.

  9. Measurement of Raman spectra of single airborne absorbing particles trapped by a single laser beam.

    PubMed

    Ling, Lin; Li, Yong-qing

    2013-02-15

    We demonstrate a method for optical trapping and Raman spectroscopy of micron-sized, airborne absorbing particles using a single focused laser beam. A single Gaussian beam at 532 nm is used to trap and precisely manipulate absorbing airborne particles. The fluctuation of the position of the trapped particles is substantially reduced by controlling the power of the laser beam with a position-sensitive detector and a locking circuit. Raman spectra of the position-stabilized particles or clusters are then measured with an objective and CCD spectrograph. PMID:23455087

  10. Absolute tracer dye concentration using airborne laser-induced water Raman backscatter

    NASA Technical Reports Server (NTRS)

    Hoge, F. E.; Swift, R. N.

    1981-01-01

    The use of simultaneous airborne-laser-induced dye fluorescence and water Raman backscatter to measure the absolute concentration of an ocean-dispersed tracer dye is discussed. Theoretical considerations of the calculation of dye concentration by the numerical comparison of airborne laser-induced fluorescence spectra with laboratory spectra for known dye concentrations using the 3400/cm OH-stretch water Raman scatter as a calibration signal are presented which show that minimum errors are obtained and no data concerning water mass transmission properties are required when the laser wavelength is chosen to yield a Raman signal near the dye emission band. Results of field experiments conducted with an airborne conical scan lidar over a site in New York Bight into which rhodamine dye had been injected in a study of oil spill dispersion are then indicated which resulted in a contour map of dye concentrations, with a minimum detectable dye concentration of approximately 2 ppb by weight.

  11. Contribution of airborne dust particles to HONO sources

    NASA Astrophysics Data System (ADS)

    Saliba, N. A.; Moussa, S. G.; El Tayyar, G.

    2014-02-01

    HONO is a major precursor for OH radicals in early mornings. Its formation has been mainly attributed to the heterogeneous hydrolysis of NO2 on surfaces such as soot, glass, mineral oxides and aerosol surfaces. In particular, dust events which are loaded with mineral oxide aerosols have been associated with higher HONO concentrations in the gas phase. In order to understand the mechanism of reactions related to this process, samples during dusty and non-dusty days were collected between October 2009 and April 2011. Based on HYSPLIT backward trajectories, data were divided between wind trajectories originating from Arabian or African deserts. In this study an increase of HONO levels was observed during dusty days. The increase in the acidic gas concentrations was accompanied by an increase in the PM nitrate and sulfate ion concentrations. During high relative humidity (African dusty days), it is proposed that the mechanism of NO2 hydrolysis predominates whereas during Arabian dusty days, where the air is relatively dry, a synergistic mechanism of adsorption and reaction between NO2 and SO2 on dust particles to produce HONO and sulfate in the particle phase is suggested. This study implies that the NOx reactivity on mineral oxide surfaces leads to a higher mixing level of OH. An increase in the sulfate forming capacity could account for the underestimation of sulfates in aerosols when the reactive uptake of SO2 alone is considered.

  12. Characterization of Hairdresser Exposure to Airborne Particles during Hair Bleaching.

    PubMed

    Nilsson, Patrik T; Marini, Sara; Wierzbicka, Aneta; Kåredal, Monica; Blomgren, Eva; Nielsen, Jörn; Buonanno, Giorgio; Gudmundsson, Anders

    2016-01-01

    Respiratory symptoms among hairdressers are often ascribed to the use of bleaching powders that contain persulfate salts. Such salts can act as allergens and airway irritants but the mechanisms behind the negative health effects are not fully known. In order to understand why some hairdressers experience respiratory symptoms during, and after, sessions of hair bleaching, it is of importance to characterize how exposure occurs. In this work we used time and particle size resolved instrumentation with the aim to measure the concentration of particles that hairdressers are exposed to during sessions of hair bleaching. We also used filter samples to collect particles for quantitative determination of persulfate (S2O8(2-)) content and for analysis by light microscopy. Two different types of bleaching powders were used, one marked as dust-free and one without this marking (denoted regular). The time resolved instrumentation revealed that particles <10 µm were emitted, specifically when the regular powder was prepared and mixed with hydrogen peroxide. In contrast to other research our work also revealed that supercoarse particles (>10 µm) were emitted during application of the bleaching, when both the regular and the dust-free powders were used. The measured level of persulfate, sampled in the breathing zone of the hairdressers, was on average 26 µg m(-3) when the regular powder was used and 11 µg m(-3) when the dust-free powder was used. This indicates that use of dust-free powder does not eliminate exposure to persulfates, it only lowers the concentration. We show that the site of sampling, or position of the hairdresser with regards to the hair being bleached, is of high importance in the determination of persulfate levels and exposure. This work focuses on the physical and chemical characterization of the particles released to the air and the results are important for accurate exposure assessments. Accurate assessments may in turn lead to a better understanding of

  13. Source apportionment of airborne particles in commercial aircraft cabin environment: Contributions from outside and inside of cabin

    NASA Astrophysics Data System (ADS)

    Li, Zheng; Guan, Jun; Yang, Xudong; Lin, Chao-Hsin

    2014-06-01

    Airborne particles are an important type of air pollutants in aircraft cabin. Finding sources of particles is conducive to taking appropriate measures to remove them. In this study, measurements of concentration and size distribution of particles larger than 0.3 μm (PM>0.3) were made on nine short haul flights from September 2012 to March 2013. Particle counts in supply air and breathing zone air were both obtained. Results indicate that the number concentrations of particles ranged from 3.6 × 102 counts L-1 to 1.2 × 105 counts L-1 in supply air and breathing zone air, and they first decreased and then increased in general during the flight duration. Peaks of particle concentration were found at climbing, descending, and cruising phases in several flights. Percentages of particle concentration in breathing zone contributed by the bleed air (originated from outside) and cabin interior sources were calculated. The bleed air ratios, outside airflow rates and total airflow rates were calculated by using carbon dioxide as a ventilation tracer in five of the nine flights. The calculated results indicate that PM>0.3 in breathing zone mainly came from unfiltered bleed air, especially for particle sizes from 0.3 to 2.0 μm. And for particles larger than 2.0 μm, contributions from the bleed air and cabin interior were both important. The results would be useful for developing better cabin air quality control strategies.

  14. Assessment of oxidative DNA damage formation by organic complex mixtures from airborne particles PM(10).

    PubMed

    Gábelová, Alena; Valovicová, Zuzana; Lábaj, Juraj; Bacová, Gabriela; Binková, Blanka; Farmer, Peter B

    2007-07-01

    The free radical generating activity of airborne particulate matter (PM(10)) has been proposed as a primary mechanism in biological activity of ambient air pollution. In an effort to determine the impact of the complex mixtures of extractable organic matter (EOM) from airborne particles on oxidative damage to DNA, the level of 8-oxo-2'-deoxyguanosine (8-oxodG), the most prevalent and stable oxidative lesion, was measured in the human metabolically competent cell line Hep G2. Cultured cells were exposed to equivalent EOM concentrations (5-150microg/ml) and oxidative DNA damage was analyzed using a modified single cell gel electrophoresis (SCGE), which involves the incubation of whole cell DNA with repair specific DNA endonuclease, which cleaves oxidized DNA at the sites of 8-oxodG. EOMs were extracted from PM(10) collected daily (24h intervals) in three European cities: Prague (Czech Republic, two monitoring sites, Libus and Smíchov), Kosice (Slovak Republic) and Sofia (Bulgaria) during 3-month sampling periods in the winter and summer seasons. No substantial time- and dose-dependent increase of oxidative DNA lesions was detected in EOM-treated cells with the exception of the EOM collected at the monitoring site Kosice, summer sampling. In this case, 2h cell exposure to EOM resulted in a slight but significant increase of oxidative DNA damage at three from total of six concentrations. The mean 8-oxodG values at these concentrations ranged from 15.3 to 26.1 per 10(6) nucleotides with a value 3.5 per 10(6) nucleotides in untreated cells. B[a]P, the positive control, induced a variable but insignificant increase of oxidative DNA damage in Hep G2 cell (approximately 1.6-fold increase over control value). Based on these data we believe that EOM samples extracted from airborne particle PM(10) play probably only a marginal role in oxidative stress generation and oxidative lesion formation to DNA. However, adsorbed organic compounds can undergo various interactions

  15. EXPOSURE TO CONCENTRATED AMBIENT PARTICLES (CAPS): REVIEW

    EPA Science Inventory

    Epidemiologic studies support a participation of fine particulate matter (PM) with a diameter of 0.1 to 2.5 microm in the effects of air pollution particles on human health. The ambient fine particle concentrator is a recently developed technology that can enrich the mass of ambi...

  16. Evidence for more than one division of bacteria within airborne particles.

    PubMed Central

    Dimmick, R L; Wolochow, H; Chatigny, M A

    1979-01-01

    When the protocol that we had used to demonstrate a single division of bacterial cells in airborne particles was changed to one that increased the glycerol content of the atomizer fluid from 1 to 5% (vol/vol), thus producing larger particles, more than two (and nearly three) divisions of bacteria occurred within 6 h of aerosol time. PMID:395898

  17. Immunological Assays as an Opportunity of Assessment of Health Risks of Airborne Particle Mixture Including Nanoparticles

    NASA Astrophysics Data System (ADS)

    Brzicová, Táňa; Lochman, Ivo; Danihelka, Pavel; Lochmanová, Alexandra; Lach, Karel; Mička, Vladimír

    2013-04-01

    The aim of this pilot study was to evaluate perspectives of the assessment of nonspecific biological effects of airborne particulate matter including nanoparticles using appropriate immunological assays. We have selected various in vitro immunological assays to establish an array allowing us to monitor activation of the cell-mediated and humoral response of both the innate and adaptive immunity. To assess comprehensive interactions and effects, the assays were performed in whole blood cultures from healthy volunteers and we used an original airborne particle mixture from high pollution period in Ostrava region representing areas with one of the most polluted air in Europe. Even if certain effects were observed, the results of the immunological assays did not prove significant effects of airborne particles on immune cells' functions of healthy persons. However, obtained data do not exclude health risks of long-term exposure to airborne particles, especially in case of individuals with genetic predisposition to certain diseases or already existing disease. This study emphasizes the in vitro assessment of complex effects of airborne particles in conditions similar to actual ones in an organism exposed to particle mixture present in the polluted air.

  18. A new look at inhalable metalliferous airborne particles on rail subway platforms.

    PubMed

    Moreno, Teresa; Martins, Vânia; Querol, Xavier; Jones, Tim; BéruBé, Kelly; Minguillón, Maria Cruz; Amato, Fulvio; Capdevila, Marta; de Miguel, Eladio; Centelles, Sonia; Gibbons, Wes

    2015-02-01

    Most particles breathed on rail subway platforms are highly ferruginous (FePM) and extremely small (nanometric to a few microns in size). High magnification observations of particle texture and chemistry on airborne PM₁₀ samples collected from the Barcelona Metro, combined with published experimental work on particle generation by frictional sliding, allow us to propose a general model to explain the origin of most subway FePM. Particle generation occurs by mechanical wear at the brake-wheel and wheel-rail interfaces, where magnetic metallic flakes and splinters are released and undergo progressive atmospheric oxidation from metallic iron to magnetite and maghemite. Flakes of magnetite typically comprise mottled mosaics of octahedral nanocrystals (10-20 nm) that become pseudomorphed by maghemite. Continued oxidation results in extensive alteration of the magnetic nanostructure to more rounded aggregates of non-magnetic hematite nanocrystals, with magnetic precursors (including iron metal) still preserved in some particle cores. Particles derived from steel wheel and rails contain a characteristic trace element chemistry, typically with Mn/Fe=0.01. Flakes released from brakes are chemically very distinctive, depending on the pad composition, being always carbonaceous, commonly barium-rich, and texturally inhomogeneous, with trace elements present in nanominerals incorporated within the crystalline structure. In the studied subway lines of Barcelona at least there appears to be only a minimal aerosol contribution from high temperature processes such as sparking. To date there is no strong evidence that these chemically and texturally complex inhalable metallic materials are any more or less toxic than street-level urban particles, and as with outdoor air, the priority in subway air quality should be to reduce high mass concentrations of aerosol present in some stations. PMID:25461038

  19. Laboratory Study of Airborne Fallout Particles and Their Time Distribution.

    ERIC Educational Resources Information Center

    Smith, H. A., Jr.; And Others

    1979-01-01

    Samples of filtered airborne particulate, collected daily for the first month after the September 18, 1977 Chinese nuclear detonation, showed fourteen fission products. Fluctuations in the daily fallout activity levels suggested a global fallout orbit time of approximately twenty days. (Author/BB)

  20. Ambient airborne solids concentrations including volcanic ash at Hanford, Washington sampling sites subsequent to the Mount St. Helens eruption

    NASA Technical Reports Server (NTRS)

    Sehmel, G. A.

    1982-01-01

    Airborne solids concentrations were measured on a near daily basis at two Hanford, Washington sites after the eruption of Mount St. Helens on May 18, 1980. These sites are about 211 km east of Mount St. Helens. Collected airborne solids included resuspended volcanic ash plus normal ambient solids. Average airborne solids concentrations were greater at the Hanford meteorological station sampling site which is 24 km northwest of the Horn Rapids dam sampling site. These increased concentrations reflect the sampling site proximity to greater ash fallout depths. Both sites are in low ash fallout areas although the Hanford meteorological station site is closer to the greater ash fallout areas. Airborne solids concentrations were decreased by rain, but airborne solids concentrations rapidly increased as surfaces dried. Airborne concentrations tended to become nearly the same at both sampling sites only for July 12 and 13.

  1. g Dependent particle concentration due to sedimentation

    NASA Astrophysics Data System (ADS)

    Haranas, Ioannis; Gkigkitzis, Ioannis; Zouganelis, George D.

    2012-11-01

    Sedimentation of particles in a fluid has long been used to characterize particle size distribution. Stokes' law is used to determine an unknown distribution of spherical particle sizes by measuring the time required for the particles to settle a known distance in a fluid of known viscosity and density. In this paper, we study the effects of gravity on sedimentation by examining the resulting particle concentration distributed in an equilibrium profile of concentration C m, n above the bottom of a container. This is for an experiment on the surface of the Earth and therefore the acceleration of gravity had been corrected for the oblateness of the Earth and its rotation. Next, at the orbital altitude of the spacecraft in orbit around Earth the acceleration due to the central field is corrected for the oblateness of the Earth. Our results show that for experiments taking place in circular or elliptical orbits of various inclinations around the Earth the concentration ratio C m, n / C m, ave , the inclination seems to be the most ineffective in affecting the concentration among all the orbital elements. For orbital experiment that use particles of diameter d p =0.001 μm the concentration ratios for circular and slightly elliptical orbits in the range e=0-0.1 exhibit a 0.009 % difference. The concentration ratio increases with the increase of eccentricity, which increases more for particles of larger diameters. Finally, for particles of the same diameter concentration ratios between Earth and Mars surface experiments are related in the following way C_{(m,n)_{mathit{Earth}}} = 0.99962 C_{(m,n)_{mathit{Mars}}}.

  2. Correlation between airborne Olea europaea pollen concentrations and levels of the major allergen Ole e 1 in Córdoba, Spain, 2012-2014

    NASA Astrophysics Data System (ADS)

    Plaza, M. P.; Alcázar, P.; Galán, C.

    2016-04-01

    Olea europaea L. pollen is the second-largest cause of pollinosis in the southern Iberian Peninsula. Airborne-pollen monitoring networks provide essential data on pollen dynamics over a given study area. Recent research, however, has shown that airborne pollen levels alone do not always provide a clear indicator of actual exposure to aeroallergens. This study sought to evaluate correlations between airborne concentrations of olive pollen and Ole e 1 allergen levels in Córdoba (southern Spain), in order to determine whether atmospheric pollen concentrations alone are sufficient to chart changes in hay fever symptoms. The influence of major weather-related variables on local airborne pollen and allergen levels was also examined. Monitoring was carried out from 2012 to 2014. Pollen sampling was performed using a Hirst-type sampler, following the protocol recommended by the Spanish Aerobiology Network. A multi-vial cyclone sampler was used to collect aeroallergens, and allergenic particles were quantified by ELISA assay. Significant positive correlations were found between daily airborne allergen levels and atmospheric pollen concentrations, although there were occasions when allergen was detected before and after the pollen season and in the absence of airborne pollen. The correlation between the two was irregular, and pollen potency displayed year-on-year variations and did not necessarily match pollen-season-intensity.

  3. Dielectrophoretic concentration of particles under electrokinetic flow

    DOEpatents

    Miles, Robin R.; Bettencourt, Kerry A.; Fuller, Christopher K.

    2004-09-07

    The use of dielectrophoresis to collect particles under the conditions of electrokinetically-driven flow. Dielectrophortic concentration of particles under electrokinetic flow is accomplished by interdigitated electrodes patterned on an inner surface of a microfluid channel, a DC voltage is applied across the ends to the channel, and an AC voltage is applied across the electrodes, and particles swept down the channel electrokinetically are trapped within the field established by the electrodes. The particles can be released when the voltage to the electrodes is released.

  4. Airborne particles of the california central valley alter the lungs of healthy adult rats.

    PubMed Central

    Smith, Kevin R; Kim, Seongheon; Recendez, Julian J; Teague, Stephen V; Ménache, Margaret G; Grubbs, David E; Sioutas, Constantinos; Pinkerton, Kent E

    2003-01-01

    Epidemiologic studies have shown that airborne particulate matter (PM) with a mass median aerodynamic diameter < 10 microm (PM10) is associated with an increase in respiratory-related disease. However, there is a growing consensus that particles < 2.5 microm (PM2.5), including many in the ultrafine (< 0.1 microm) size range, may elicit greater adverse effects. PM is a complex mixture of organic and inorganic compounds; however, those components or properties responsible for biologic effects on the respiratory system have yet to be determined. During the fall and winter of 2000-2001, healthy adult Sprague-Dawley rats were exposed in six separate experiments to filtered air or combined fine (PM2.5) and ultrafine portions of ambient PM in Fresno, California, enhanced approximately 20-fold above outdoor levels. The intent of these studies was to determine if concentrated fine/ultrafine fractions of PM are cytotoxic and/or proinflammatory in the lungs of healthy adult rats. Exposures were for 4 hr/day for 3 consecutive days. The mean mass concentration of particles ranged from 190 to 847 microg/m3. PM was enriched primarily with ammonium nitrate, organic and elemental carbon, and metals. Viability of cells recovered by bronchoalveolar lavage (BAL) from rats exposed to concentrated PM was significantly decreased during 4 of 6 weeks, compared with rats exposed to filtered air (p< 0.05). Total numbers of BAL cells were increased during 1 week, and neutrophil numbers were increased during 2 weeks. These observations strongly suggest exposure to enhanced concentrations of ambient fine/ultrafine particles in Fresno is associated with mild, but significant, cellular effects in the lungs of healthy adult rats. PMID:12782490

  5. Performance of N95 respirators: filtration efficiency for airborne microbial and inert particles.

    PubMed

    Qian, Y; Willeke, K; Grinshpun, S A; Donnelly, J; Coffey, C C

    1998-02-01

    In 1995 the National Institute for Occupational Safety and Health issued new regulations for nonpowered particulate respirators (42 CFR Part 84). A new filter certification system also was created. Among the new particulate respirators that have entered the market, the N95 respirator is the most commonly used in industrial and health care environments. The filtration efficiencies of unloaded N95 particulate respirators have been compared with those of dust/mist (DM) and dust/fume/mist (DFM) respirators certified under the former regulations (30 CFR Part 11). Through laboratory tests with NaCl certification aerosols and measurements with particle-size spectrometers, N95 respirators were found to have higher filtration efficiencies than DM and DFM respirators and noncertified surgical masks. N95 respirators made by different companies were found to have different filtration efficiencies for the most penetrating particle size (0.1 to 0.3 micron), but all were at least 95% efficient at that size for NaCl particles. Above the most penetrating particle size the filtration efficiency increases with size; it reaches approximately 99.5% or higher at about 0.75 micron. Tests with bacteria of size and shape similar to Mycobacterium tuberculosis also showed filtration efficiencies of 99.5% or higher. Experimental data were used to calculate the aerosol mass concentrations inside the respirator when worn in representative work environments. The penetrated mass fractions, in the absence of face leakage, ranged from 0.02% for large particle distributions to 1.8% for submicrometer-size welding fumes. Thus, N95 respirators provide excellent protection against airborne particles when there is a good face seal. PMID:9487666

  6. On the interaction between glyceraldehyde-3-phosphate dehydrogenase and airborne particles: Evidence for electrophilic species

    NASA Astrophysics Data System (ADS)

    Shinyashiki, Masaru; Rodriguez, Chester E.; Di Stefano, Emma W.; Sioutas, Constantinos; Delfino, Ralph J.; Kumagai, Yoshito; Froines, John R.; Cho, Arthur K.

    Many of the adverse health effects of airborne particulate matter (PM) have been attributed to the chemical properties of some of the large number of chemical species present in PM. Some PM component chemicals are capable of generating reactive oxygen species and eliciting a state of oxidative stress. In addition, however, PM can contain chemical species that elicit their effects through covalent bond formation with nucleophilic functions in the cell. In this manuscript, we report the presence of constituents with electrophilic properties in ambient and diesel exhaust particles, demonstrated by their ability to inhibit the thiol enzyme, glyceraldehyde-3-phosphate dehydrogenase (GAPDH). GAPDH is irreversibly inactivated by electrophiles under anaerobic conditions by covalent bond formation. This inactivation can be blocked by the prior addition of a high concentration of dithiothreitol (DTT) as an alternate nucleophile. Addition of DTT after the reaction between the electrophile and GAPDH, however, does not reverse the inactivation. This property has been utilized to develop a procedure that provides a quantitative measure of electrophiles present in samples of ambient particles collected in the Los Angeles Basin and in diesel exhaust particles. The toxicity of electrophiles is the result of irreversible changes in biological molecules; recovery is dependent on resynthesis. If the resynthesis is slow, the irreversible effects can be cumulative and manifest themselves after chronic exposure to low levels of electrophiles.

  7. Plasmonic spectra of individual subwavelength particles under the infrared microscope: cells and airborne dust

    NASA Astrophysics Data System (ADS)

    Coe, James V.; Lioi, David B.; Shaffer, Lindsey; Malone, Marvin A.; Luthra, Antriksh; Ravi, Aruna

    2014-03-01

    A plasmonic metal film with a subwavelength hole array (a mesh) is used to capture an individual subwavelength particle, like a single yeast cell or airborne dust particle, and an imaging infrared (IR) microscope, records a scatterfree, IR absorption spectrum of the particle. Individual spectra of wavelength scale particles usually suffer from large scattering effects. This paper starts by demonstrating the plasmonic nature of the mesh in the infrared, proceeds to how this special form of light (surface plasmon polariton mediated transmission resonance) leads to scatter-free IR absorption spectra of individual, subwavelength particles, and ends with work on yeast cells and dust particles from our laboratory air and a household filter.

  8. Airborne endotoxin concentrations at a large open-lot dairy in southern idaho.

    PubMed

    Dungan, Robert S; Leytem, April B

    2009-01-01

    Endotoxins are derived from gram-negative bacteria and are a potential respiratory health risk for animals and humans. To determine the potential for endotoxin transport from a large open-lot dairy, total airborne endotoxin concentrations were determined at an upwind location (background) and five downwind locations on three separate days. The downwind locations were situated at of the edge of the lot, 200 and 1390 m downwind from the lot, and downwind from a manure composting area and wastewater holding pond. When the wind was predominantly from the west, the average endotoxin concentration at the upwind location was 24 endotoxin units (EU) m(-3), whereas at the edge of the lot on the downwind side it was 259 EU m(-3). At 200 and 1390 m downwind from the edge of the lot, the average endotoxin concentrations were 168 and 49 EU m(-3), respectively. Average airborne endotoxin concentrations downwind from the composting site (36 EU m(-3)) and wastewater holding pond (89 EU m(-3)) and 1390 m from the edge of the lot were not significantly different from the upwind location. There were no significant correlations between ambient weather data collected and endotoxin concentrations over the experimental period. The downwind data show that the airborne endotoxin concentrations decreased exponentially with distance from the lot edge. Decreasing an individual's proximity to the dairy should lower their risk of airborne endotoxin exposure and associated health effects. PMID:19643758

  9. Airborne particle monitoring with urban closed-circuit television camera networks and a chromatic technique

    NASA Astrophysics Data System (ADS)

    Kolupula, Y. R.; Aceves-Fernandez, M. A.; Jones, G. R.; Deakin, A. G.; Spencer, J. W.

    2010-11-01

    An economic approach for the preliminary assessment of 2-10 µm sized (PM10) airborne particle levels in urban areas is described. It uses existing urban closed-circuit television (CCTV) surveillance camera networks in combination with particle accumulating units and chromatic quantification of polychromatic light scattered by the captured particles. Methods for accommodating extraneous light effects are discussed and test results obtained from real urban sites are presented to illustrate the potential of the approach.

  10. Environmental assessment of three egg production systems - Part III: Airborne bacteria concentrations and emissions.

    PubMed

    Zhao, Y; Zhao, D; Ma, H; Liu, K; Atilgan, A; Xin, H

    2016-07-01

    Airborne microorganism level is an important indoor air quality indicator, yet it has not been well documented for laying-hen houses in the United States. As a part of the Coalition for Sustainable Egg Supply (CSES) environmental monitoring project, this study comparatively monitored the concentrations and emissions of airborne total and Gram-negative (Gram(-)) bacteria in three types of commercial laying-hen houses, i.e., conventional cage (CC), aviary (AV), and enriched colony (EC) houses, over a period of eight months covering the mid and late stages of the flock cycle. It also delineated the relationship between airborne total bacteria and particulate matter smaller than 10 μm in aerodynamic diameter (PM10). The results showed airborne total bacteria concentrations (log CFU/m(3)) of 4.7 ± 0.3 in CC, 6.0 ± 0.8 in AV, and 4.8 ± 0.3 in EC, all being higher than the level recommended for human environment (3.0 log CFU/m(3)). The much higher concentrations in AV arose from the presence of floor litter and hen activities on it, as evidenced by the higher concentrations in the afternoon (with litter access) than in the morning (without litter access). The overall means and standard deviation of airborne total bacteria emission rates, in log CFU/[h-hen] (or log CFU/[h-AU], AU = animal unit or 500 kg live weight) were 4.8 ± 0.4 (or 7.3 ± 0.4) for CC, 6.1 ± 0.7 (or 8.6 ± 0.7) for AV, and 4.8 ± 0.5 (or 7.3 ± 0.5) for EC. Both concentration and emission rate of airborne total bacteria were positively related to PM10 Gram(-) bacteria were present at low concentrations in all houses; and only 2 samples (6%) in CC, 7 (22%) samples in AV, and 2 (6%) samples in EC out of 32 air samples collected in each house were found positive with Gram(-) bacteria. The concentration of airborne Gram(-) bacteria was estimated to be <2% of the total bacteria. Total bacteria counts in manure on belt (in all houses) and floor litter (only in AV) were similar; however, the manure had

  11. Airborne particle generation for optical tweezers by thermo-mechanical membrane actuators

    NASA Astrophysics Data System (ADS)

    Polster, T.; Leopold, S.; Hoffmann, M.

    2011-06-01

    This article presents a new approach for airborne particle generation for optical tweezers. The used element is a 500 nm thin aluminum nitride membrane with an integrated heating element. Thus the membrane works as thermo-mechanical actor. The membrane device is characterized concerning their mechanical and thermal behavior. Successful airborne particle generation is demonstrated with 10 μm silicon dioxide spheres. They are lifted up some 10th of μm from the membrane surface. The development and test of this device serves as starting point for experiments with optical tweezers in air.

  12. Concentrations, sources and geochemistry of airborne particulate matter at a major European airport.

    PubMed

    Amato, Fulvio; Moreno, Teresa; Pandolfi, Marco; Querol, Xavier; Alastuey, Andrés; Delgado, Ana; Pedrero, Manuel; Cots, Nuria

    2010-04-01

    Monitoring of aerosol particle concentrations (PM(10), PM(2.5), PM(1)) and chemical analysis (PM(10)) was undertaken at a major European airport (El Prat, Barcelona) for a whole month during autumn 2007. Concentrations of airborne PM at the airport were close to those at road traffic hotspots in the nearby Barcelona city, with means measuring 48 microg PM(10)/m(3), 21 microg PM(2.5)/m(3) and 17 microg PM(1)/m(3). Meteorological controls on PM at El Prat are identified as cleansing daytime sea breezes with abundant coarse salt particles, alternating with nocturnal land-sourced winds which channel air polluted by industry and traffic (PM(1)/PM(10) ratios > 0.5) SE down the Llobregat Valley. Chemical analyses of the PM(10) samples show that crustal PM is dominant (38% of PM(10)), followed by total carbon (OC + EC, 25%), secondary inorganic aerosols (SIA, 20%), and sea salt (6%). Local construction work for a new airport terminal was an important contributor to PM(10) crustal levels. Source apportionment modelling PCA-MLRA identifies five factors: industrial/traffic, crustal, sea salt, SIA, and K(+) likely derived from agricultural biomass burning. Whereas most of the atmospheric contamination concerning ambient air PM(10) levels at El Prat is not attributable directly to aircraft movement, levels of carbon are unusually high (especially organic carbon), as are metals possibly sourced from tyre detritus/smoke in runway dust (Ba, Zn, Mo) and from brake dust in ambient PM(10) (Cu, Sb), especially when the airport is at its most busy. We identify microflakes of aluminous alloys in ambient PM(10) filters derived from corroded fuselage and wings as an unequivocal and highly distinctive tracer for aircraft movement. PMID:20383366

  13. Particle Size Concentration Distribution and Influences on Exhaled Breath Particles in Mechanically Ventilated Patients

    PubMed Central

    Chen, Yi-Fang; Huang, Sheng-Hsiu; Wang, Yu-Ling; Chen, Chun-Wan

    2014-01-01

    Humans produce exhaled breath particles (EBPs) during various breath activities, such as normal breathing, coughing, talking, and sneezing. Airborne transmission risk exists when EBPs have attached pathogens. Until recently, few investigations had evaluated the size and concentration distributions of EBPs from mechanically ventilated patients with different ventilation mode settings. This study thus broke new ground by not only evaluating the size concentration distributions of EBPs in mechanically ventilated patients, but also investigating the relationship between EBP level and positive expiratory end airway pressure (PEEP), tidal volume, and pneumonia. This investigation recruited mechanically ventilated patients, with and without pneumonia, aged 20 years old and above, from the respiratory intensive care unit of a medical center. Concentration distributions of EBPs from mechanically ventilated patients were analyzed with an optical particle analyzer. This study finds that EBP concentrations from mechanically ventilated patients during normal breathing were in the range 0.47–2,554.04 particles/breath (0.001–4.644 particles/mL). EBP concentrations did not differ significantly between the volume control and pressure control modes of the ventilation settings in the mechanically ventilated patients. The patient EBPs were sized below 5 µm, and 80% of them ranged from 0.3 to 1.0 µm. The EBPs concentrations in patients with high PEEP (> 5 cmH2O) clearly exceeded those in patients with low PEEP (≤ 5 cmH2O). Additionally, a significant negative association existed between pneumonia duration and EBPs concentration. However, tidal volume was not related to EBPs concentration. PMID:24475230

  14. Surface and Airborne Arsenic Concentrations in a Recreational Site near Las Vegas, Nevada, USA

    PubMed Central

    Goossens, Dirk

    2015-01-01

    Elevated concentrations of arsenic, up to 7058 μg g-1 in topsoil and bedrock, and more than 0.03 μg m-3 in air on a 2-week basis, were measured in the Nellis Dunes Recreation Area (NDRA), a very popular off-road area near Las Vegas, Nevada, USA. The elevated arsenic concentrations in the topsoil and bedrock are correlated to outcrops of yellow sandstone belonging to the Muddy Creek Formation (≈ 10 to 4 Ma) and to faults crossing the area. Mineralized fluids moved to the surface through the faults and deposited the arsenic. A technique was developed to calculate airborne arsenic concentrations from the arsenic content in the topsoil. The technique was tested by comparing calculated with measured concentrations at 34 locations in the NDRA, for 3 periods of 2 weeks each. We then applied it to calculate airborne arsenic concentrations for more than 500 locations all over the NDRA. The highest airborne arsenic concentrations occur over sand dunes and other zones with a surficial layer of aeolian sand. Ironically these areas show the lowest levels of arsenic in the topsoil. However, they are highly susceptible to wind erosion and emit very large amounts of sand and dust during episodes of strong winds, thereby also emitting much arsenic. Elsewhere in the NDRA, in areas not or only very slightly affected by wind erosion, airborne arsenic levels equal the background level for airborne arsenic in the USA, approximately 0.0004 μg m-3. The results of this study are important because the NDRA is visited by more than 300,000 people annually. PMID:25897667

  15. Year-long assessment of airborne endotoxin at a concentrated dairy operation

    Technology Transfer Automated Retrieval System (TEKTRAN)

    With the increasing prevalence of concentrated animal feeding operations (CAFOs), concern over bioaerosols drifting in downwind plumes is gaining attention as they may cause health effects in humans and livestock. In this study, we monitored total airborne endotoxins at upwind and downwind locations...

  16. AIRBORNE ASBESTOS CONCENTRATIONS DURING BUFFING, BURNISHING, AND STRIPPING OF RESILIENT FLOOR TILE

    EPA Science Inventory

    This study was conducted to evaluate airborne asbestos concentrations during low-speed spray-buffing, ultra high-speed burnishing, and wet-stripping of asbestos-containing resilient floor tile under preexisting and prepared levels of floor care maintenance. ow-speed spray-buffing...

  17. A Computer Code to Estimate Environmental Concentration and Dose Due to Airborne Release of Radioactive Material.

    1991-03-15

    Version 00 ORION-II was developed to estimate environmental concentration and dose due to airborne release of radioactive material from multiple sources of the nuclear fuel cycle facilities. ORION-II is an updated version of ORION and is applicable to the sensitivity study of dose assessment at nuclear fuel cycle facilities.

  18. AIRBORNE ASBESTOS CONCENTRATIONS DURING BUFFING, BURNISHING, AND STRIPPING OF RESILIENT FLOOR TILE

    EPA Science Inventory

    The study was conducted to evaluate airborne asbestos concentrations during low-speed spray-buffing, ultra high-speed burnishing, and wet-stripping of asbestos-containing resilient floor tile under pre-existing and prepared levels of floor care maintenance. Low-speed spray-buffin...

  19. Concentrations of airborne endotoxin and microorganisms at a 10,000 cow open-freestall dairy

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Confined animal production systems produce elevated bioaerosol concentrations, which are a potential respiratory health risk to individuals on site and downwind. In this study, airborne endotoxin and microorganisms were collected during the spring, summer, and fall at a large open-freestall dairy i...

  20. Airborne endotoxin concentrations at a large open-lot dairy in southern Idaho

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Endotoxins are derived from Gram-negative bacteria and are a potential respiratory health risk for animals and humans. To determine the potential for endotoxin transport from a large open lot dairy, airborne endotoxin concentrations were determined at an upwind location (background) and five downwi...

  1. Qualitative and quantitative methodologies for determination of airborne microorganisms at concentrated animal-feeding operations

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The generation of bioaerosols from concentrated animal feeding operations (CAFOs) is a concern from a human and animal health perspective. To better understand the airborne microorganisms found in these environments, a number of collection and analytical techniques have been utilized and will be di...

  2. Spacecraft maximum allowable concentrations for selected airborne contaminants, volume 1

    NASA Technical Reports Server (NTRS)

    1994-01-01

    As part of its efforts to promote safe conditions aboard spacecraft, NASA requested the National Research Council (NRC) to develop guidelines for establishing spacecraft maximum allowable concentrations (SMAC's) for contaminants, and to review SMAC's for various spacecraft contaminants to determine whether NASA's recommended exposure limits are consistent with the guidelines recommended by the subcommittee. In response to NASA's request, the NRC organized the Subcommittee on Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants within the Committee on Toxicology (COT). In the first phase of its work, the subcommittee developed the criteria and methods for preparing SMAC's for spacecraft contaminants. The subcommittee's report, entitled Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants, was published in 1992. The executive summary of that report is reprinted as Appendix A of this volume. In the second phase of the study, the Subcommittee on Spacecraft Maximum Allowable Concentrations reviewed reports prepared by NASA scientists and contractors recommending SMAC's for 35 spacecraft contaminants. The subcommittee sought to determine whether the SMAC reports were consistent with the 1992 guidelines. Appendix B of this volume contains the first 11 SMAC reports that have been reviewed for their application of the guidelines developed in the first phase of this activity and approved by the subcommittee.

  3. Assessment of Airborne Particles. Fundamentals, Applications, and Implications to Inhalation Toxicity.

    ERIC Educational Resources Information Center

    Mercer, Thomas T., Ed.; And Others

    Concern over chemical and radioactive particulate matter in industry and over rapidly increasing air pollution has stimulated research both on the properties of airborne particles and methods for assessing them and on their biological effects following inhalation. The Third Rochester International Conference on Environmental Toxicity was,…

  4. A method to quantify infectious airborne pathogens at concentrations below the threshold of quantification by culture

    PubMed Central

    Cutler, Timothy D.; Wang, Chong; Hoff, Steven J.; Zimmerman, Jeffrey J.

    2013-01-01

    In aerobiology, dose-response studies are used to estimate the risk of infection to a susceptible host presented by exposure to a specific dose of an airborne pathogen. In the research setting, host- and pathogen-specific factors that affect the dose-response continuum can be accounted for by experimental design, but the requirement to precisely determine the dose of infectious pathogen to which the host was exposed is often challenging. By definition, quantification of viable airborne pathogens is based on the culture of micro-organisms, but some airborne pathogens are transmissible at concentrations below the threshold of quantification by culture. In this paper we present an approach to the calculation of exposure dose at microbiologically unquantifiable levels using an application of the “continuous-stirred tank reactor (CSTR) model” and the validation of this approach using rhodamine B dye as a surrogate for aerosolized microbial pathogens in a dynamic aerosol toroid (DAT). PMID:24082399

  5. Airborne observations of new particle formation events in the boundary layer using a Zeppelin

    NASA Astrophysics Data System (ADS)

    Lampilahti, Janne; Manninen, Hanna E.; Nieminen, Tuomo; Mirme, Sander; Pullinen, Iida; Yli-Juuti, Taina; Schobesberger, Siegfried; Kangasluoma, Juha; Kontkanen, Jenni; Lehtipalo, Katrianne; Ehn, Mikael; Mentel, Thomas F.; Petäjä, Tuukka; Kulmala, Markku

    2014-05-01

    Atmospheric new particle formation (NPF) is a frequent and ubiquitous process in the atmosphere and a major source of newly formed aerosol particles [1]. However, it is still unclear how the aerosol particle distribution evolves in space and time during an NPF. We investigated where in the planetary boundary layer does NPF begin and how does the aerosol number size distribution develop in space and time during it. We measured in Hyytiälä, southern Finland using ground based and airborne measurements. The measurements were part of the PEGASOS project. NPF was studied on six scientific flights during spring 2013 using a Zeppelin NT class airship. Ground based measurements were simultaneously conducted at SMEAR II station located in Hyytiälä. The flight profiles over Hyytiälä were flown between sunrise and noon during the growth of the boundary layer. The profiles over Hyytiälä covered vertically a distance of 100-1000 meters reaching the mixed layer, stable (nocturnal) boundary layer and the residual layer. Horizontally the profiles covered approximately a circular area of four kilometers in diameter. The measurements include particle number size distribution by Neutral cluster and Air Ion Spectrometer (NAIS), Differential Mobility Particle Sizer (DMPS) and Particle Size Magnifier (PSM) [2], meteorological parameters and position (latitude, longitude and altitude) of the Zeppelin. Beginning of NPF was determined from an increase in 1.7-3 nm ion concentration. Height of the mixed layer was estimated from relative humidity measured on-board the Zeppelin. Particle growth rate during NPF was calculated. Spatial inhomogeneities in particle number size distribution during NPF were located and the birthplace of the particles was estimated using the growth rate and trajectories. We observed a regional NPF event that began simultaneously and evolved uniformly inside the mixed layer. In the horizontal direction we observed a long and narrow high concentration plume of

  6. Spacecraft Maximum Allowable Concentrations for Selected Airborne Contaminants. Volume 5

    NASA Technical Reports Server (NTRS)

    2008-01-01

    To protect space crews from air contaminants, NASA requested that the National Research Council (NRC) provide guidance for developing spacecraft maximum allowable concentrations (SMACs) and review NASA's development of exposure guidelines for specific chemicals. The NRC convened the Committee on Spacecraft Exposure Guidelines to address this task. The committee published Guidelines for Developing Spacecraft Maximum Allowable Concentrations for Space Station Contaminants (NRC 1992). The reason for the review of chemicals in Volume 5 is that many of them have not been examined for more than 10 years, and new research necessitates examining the documents to ensure that they reflect current knowledge. New knowledge can be in the form of toxicologic data or in the application of new approaches for analysis of available data. In addition, because NASA anticipates longer space missions beyond low Earth orbit, SMACs for 1,000-d exposures have also been developed.

  7. Spacecraft maximum allowable concentrations for selected airborne contaminants. Volume 2

    SciTech Connect

    1996-04-01

    The Subcommittee on Spacecraft Maximum Allowable Concentrations (SMAC) reviewed reports prepared by NASA scientists nd contractors recommending SMACs for approximately 35 spacecraft contaminants. The subcommittee sought to determine whether the SMAC reports were consistent with the 1992 guidelines. Appendix B of this volume contains the SMAC reports for 12 chemical contaminants that have been reviewed for their application of the guidelines developed in the first phase of this activity and approved by the subcommittee. This report is the second volume in the series.

  8. Acoustic concentration of particles in fluid flow

    DOEpatents

    Ward, Michael D.; Kaduchak, Gregory

    2010-11-23

    An apparatus for acoustic concentration of particles in a fluid flow includes a substantially acoustically transparent membrane and a vibration generator that define a fluid flow path therebetween. The fluid flow path is in fluid communication with a fluid source and a fluid outlet and the vibration generator is disposed adjacent the fluid flow path and is capable of producing an acoustic field in the fluid flow path. The acoustic field produces at least one pressure minima in the fluid flow path at a predetermined location within the fluid flow path and forces predetermined particles in the fluid flow path to the at least one pressure minima.

  9. An analytical electron microscope study of airborne industrial particles in Sosnowiec, Poland

    NASA Astrophysics Data System (ADS)

    Rietmeijer, Frans J. M.; Janeczek, Janusz

    The types and the relative amounts of airborne particles in the city of Sosnowiec (Poland) during 21-22 June, 1994 were identified by analytical electron microscope analyses. They are mostly aspherical angular Al-bearing silica particles (0.1-5.15 μm) and clusters thereof. Carbonaceous particles form sheets of soluble volatile-rich materials (0.3-33.9 μm) and rare soot. Numerous nanometer-sized Al-bearing silica grains and salt minerals are associated with the larger particles. They resulted from inefficient combustion of low-grade coals by the local industries whereby the silica particles are coal impurities that survived combustion. The total particle emission was constant during a 24 h period but silica shards dominated the nighttime emission while carbonaceous particles abounded during the daytime. This study showed that tropospheric particles in regions dominated by inefficient coal combustion are fundamentally different from typical coal fly ash spheres.

  10. Characterization of the airborne concentrations of lead in U. S. industry

    SciTech Connect

    Froines, J.R.; Baron, S.; Wegman, D.H.; O'Rourke, S. )

    1990-01-01

    Occupational exposure to lead represents a continuing problem of significant magnitude in the United States. To characterize the problem for surveillance purposes, an analysis of the airborne concentrations of lead identified in OSHA compliance inspections was conducted for the years 1979 to 1985. The five specific objectives of the study were: (1) to examine the distribution of air lead concentration in industrial environments; (2) to determine the secular trends in air lead concentrations for high lead industries; (3) to assess which job titles had excessive airborne lead concentrations; (4) to evaluate whether there was a relationship between lead overexposure and company size, unionization, or type of inspection; and (5) to investigate the prevalence of respirator violations for lead. Fifty-two industries were identified which had more than 1/3 of their inspection medians greater than the permissible exposure limit. These included primary and secondary lead smelting, battery manufacture, pigment manufacture, brass/bronze foundries, as well as 46 other industries. There has been little if any improvement in the prevalence and severity of airborne lead concentrations for the high lead industries, battery manufacture, secondary smelting, pigment manufacture, and brass/bronze foundries. Specific high exposure job titles are identified for certain high lead industries. The job title of painting stands out as an especially problematical job title across a number of industries. The prevalence of respirator violations is approximately 20% of all lead inspections.

  11. Concentration and Emission of Airborne Contaminants in a Laboratory Animal Facility Housing Rabbits

    PubMed Central

    Ooms, Tara G; Artwohl, James E; Conroy, Lorraine M; Schoonover, Todd M; Fortman, Jeffrey D

    2008-01-01

    Characterization of animal housing conditions can determine the frequency of bedding and cage changes, which are not standardized from facility to facility. Rabbits produce noticeable odors, and their excreta can scald and stain cages. Our facility wanted to document measurable airborne contaminants in a laboratory rabbit room in which excreta pans were changed weekly and cages changed biweekly. Contaminants included particulate, endotoxin, ammonia, carbon dioxide, and a rabbit salivary protein as a marker for rabbit allergen. Concentrations were measured daily over a 2-wk period in a laboratory animal facility to determine whether they increased over time and on days considered to be the dirtiest. Except for ammonia, concentrations of all airborne contaminants did not differ between clean and dirty days. Concentrations were lower than occupational health exposure guidelines for all contaminants studied, including ammonia. After measurement of concentration, a model was applied to calculate mean emission factors in this rabbit room. Examples of emission factor utilization to determine airborne contaminant concentration in rabbit rooms under various environmental conditions and housing densities are provided. PMID:18351721

  12. Aerosol-fluorescence spectrum analyzer: real-time measurement of emission spectra of airborne biological particles

    NASA Astrophysics Data System (ADS)

    Hill, Steven C.; Pinnick, Ronald G.; Nachman, Paul; Chen, Gang; Chang, Richard K.; Mayo, Michael W.; Fernandez, Gilbert L.

    1995-10-01

    We have assembled an aerosol-fluorescence spectrum analyzer (AFS), which can measure the fluorescence spectra and elastic scattering of airborne particles as they flow through a laser beam. The aerosols traverse a scattering cell where they are illuminated with intense (50 kW/cm 2) light inside the cavity of an argon-ion laser operating at 488 nm. This AFS can obtain fluorescence spectra of individual dye-doped polystyrene microspheres as small as 0.5 mu m in diameter. The spectra obtained from microspheres doped with pink and green-yellow dyes are clearly different. We have also detected the fluorescence spectra of airborne particles (although not single particles) made from various

  13. Airborne measurements of NOx, tracer species, and small particles during the European Lightning Nitrogen Oxides Experiment

    NASA Astrophysics Data System (ADS)

    Huntrieser, H.; Feigl, C.; Schlager, H.; Schröder, F.; Gerbig, C.; van Velthoven, P.; Flatøy, F.; Théry, C.; Petzold, A.; Höller, H.; Schumann, U.

    2002-06-01

    Airborne in situ measurements of NO, NO2, NOy, CO, CO2, O3, J(NO2), and CN were performed in European thunderstorms during the field experiment EULINOX in July 1998. The measurements in the upper troposphere show enhanced NOx (= NO + NO2) concentrations within thunderstorms and their outflow at horizontal scales from 300 m to several 100 km. The maximum NO mixing ratio measured inside a thundercloud close to lightning (the aircraft was also hit by a small lightning strike) was 25 ppbv. A regional NOx enhancement of 0.5 ppbv over central Europe could be traced back to a thunderstorm event starting ~24 hours earlier over Spain. The fractions of NOx in thunderclouds which are produced by lightning and convectively transported from the polluted boundary layer are determined by using CO2 and CO as tracers for boundary layer air. The analyses show that on average about 70% of the NOx increase measured in the anvil region was found to result from production by lightning and about 30% from NOx in the boundary layer. Thunderstorms are also strong sources of small particles. The peak CN concentrations measured within thunderstorm outflows (>30,000 particles STP cm-3) were distinctly higher than in the polluted boundary layer. The amount of NOx produced per thunderstorm and NO produced per lightning flash was estimated. The results imply that the annual mean NOx budget in the upper troposphere over Europe is dominated by aircraft emissions (0.1 TgN yr-1) in comparison to lightning production (~0.03 TgN yr-1). On the global scale, NOx produced by lightning (mean 3 TgN yr-1) prevails over aircraft-produced NOx (0.6 TgN yr-1).

  14. Characterizing the impact of urban emissions on regional aerosol particles: airborne measurements during the MEGAPOLI experiment

    NASA Astrophysics Data System (ADS)

    Freney, E. J.; Sellegri, K.; Canonaco, F.; Colomb, A.; Borbon, A.; Michoud, V.; Doussin, J.-F.; Crumeyrolle, S.; Amarouche, N.; Pichon, J.-M.; Bourianne, T.; Gomes, L.; Prevot, A. S. H.; Beekmann, M.; Schwarzenböeck, A.

    2014-02-01

    The MEGAPOLI (Megacities: Emissions, urban, regional and Global Atmospheric POLlution and climate effects, and Integrated tools for assessment and mitigation) experiment took place in July 2009. The aim of this campaign was to study the aging and reactions of aerosol and gas-phase emissions in the city of Paris. Three ground-based measurement sites and several mobile platforms including instrument equipped vehicles and the ATR-42 aircraft were involved. We present here the variations in particle- and gas-phase species over the city of Paris, using a combination of high-time resolution measurements aboard the ATR-42 aircraft. Particle chemical composition was measured using a compact time-of-flight aerosol mass spectrometer (C-ToF-AMS), giving detailed information on the non-refractory submicron aerosol species. The mass concentration of black carbon (BC), measured by a particle absorption soot photometer (PSAP), was used as a marker to identify the urban pollution plume boundaries. Aerosol mass concentrations and composition were affected by air-mass history, with air masses that spent longest time over land having highest fractions of organic aerosol and higher total mass concentrations. The Paris plume is mainly composed of organic aerosol (OA), BC, and nitrate aerosol, as well as high concentrations of anthropogenic gas-phase species such as toluene, benzene, and NOx. Using BC and CO as tracers for air-mass dilution, we observe the ratio of ΔOA / ΔBC and ΔOA / ΔCO increase with increasing photochemical age (-log(NOx / NOy)). Plotting the equivalent ratios of different organic aerosol species (LV-OOA, SV-OOA, and HOA) illustrate that the increase in OA is a result of secondary organic aerosol (SOA) formation. Within Paris the changes in the ΔOA / ΔCO are similar to those observed during other studies in London, Mexico City, and in New England, USA. Using the measured SOA volatile organic compounds (VOCs) species together with organic aerosol formation

  15. Characterizing the impact of urban emissions on regional aerosol particles; airborne measurements during the MEGAPOLI experiment

    NASA Astrophysics Data System (ADS)

    Freney, E. J.; Sellegri, K.; Canonaco, F.; Colomb, A.; Borbon, A.; Michoud, V.; Doussin, J.-F.; Crumeyrolle, S.; Amarouch, N.; Pichon, J.-M.; Prévôt, A. S. H.; Beekmann, M.; Schwarzenböeck, A.

    2013-09-01

    The MEGAPOLI experiment took place in July 2009. The aim of this campaign was to study the aging and reactions of aerosol and gas-phase emissions in the city of Paris. Three ground-based measurement sites and several mobile platforms including instrument equipped vehicles and the ATR-42 aircraft were involved. We present here the variations in particle- and gas-phase species over the city of Paris using a combination of high-time resolution measurements aboard the ATR-42 aircraft. Particle chemical composition was measured using a compact time-of-flight aerosol mass spectrometer (C-ToF-AMS) giving detailed information of the non-refractory submicron aerosol species. The mass concentration of BC, measured by a particle absorption soot photometer (PSAP), was used as a marker to identify the urban pollution plume boundaries. Aerosol mass concentrations and composition were affected by air-mass history, with air masses that spent longest time over land having highest fractions of organic aerosol and higher total mass concentrations. The Paris plume is mainly composed of organic aerosol (OA), black carbon and nitrate aerosol, as well as high concentrations of anthropogenic gas-phase species such as toluene, benzene, and NOx. Using BC and CO as tracers for air-mass dilution, we observe the ratio of ΔOA / ΔBC and ΔOA / ΔCO increase with increasing photochemical age (-log(NOx / NOy). Plotting the equivalent ratios for the Positive Matrix Factorization (PMF) resolved species (LV-OOA, SV-OOA, and HOA) illustrate that the increase in OA is a result of secondary organic aerosol (SOA). Within Paris the changes in the ΔOA / ΔCO are similar to those observed during other studies in Mexico city, Mexico and in New England, USA. Using the measured VOCs species together with recent organic aerosol formation yields we predicted ~ 50% of the measured organics. These airborne measurements during the MEGAPOLI experiment show that urban emissions contribute to the formation of OA

  16. Airborne measurements of cloud-forming nuclei and aerosol particles in stabilized ground clouds produced by solid rocket booster firings

    NASA Technical Reports Server (NTRS)

    Hindman, E. E., II; Ala, G. G.; Parungo, F. P.; Willis, P. T.; Bendura, R. J.; Woods, D.

    1978-01-01

    Airborne measurements of cloud volumes, ice nuclei and cloud condensation nuclei, liquid particles, and aerosol particles were obtained from stabilized ground clouds (SGCs) produced by Titan 3 launches at Kennedy Space Center, 20 August and 5 September 1977. The SGCs were bright, white, cumulus clouds early in their life and contained up to 3.5 g/m3 of liquid in micron to millimeter size droplets. The measured cloud volumes were 40 to 60 cu km five hours after launch. The SGCs contained high concentrations of cloud condensation nuclei active at 0.2%, 0.5%, and 1.0% supersaturation for periods of three to five hours. The SGCs also contained high concentrations of submicron particles. Three modes existed in the particle population: a 0.05 to 0.1 micron mode composed of aluminum-containing particles, a 0.2 to 0.8 micron mode, and a 2.0 to 10 micron mode composed of particles that contained primarily aluminum.

  17. Comparison of Three Real-Time Measurement Methods for Airborne Ultrafine Particles in the Silicon Alloy Industry.

    PubMed

    Kero, Ida Teresia; Jørgensen, Rikke Bramming

    2016-01-01

    The aim of this study was to compare the applicability and the correlation between three commercially available instruments capable of detection, quantification, and characterization of ultrafine airborne particulate matter in the industrial setting of a tapping area in a silicon alloy production plant. The number concentration of ultrafine particles was evaluated using an Electric Low Pressure Impactor (ELPI(TM)), a Fast Mobility Particle Sizer (FMPS(TM)), and a Condensation Particle Counter (CPC). The results are discussed in terms of particle size distribution and temporal variations linked to process operations. The instruments show excellent temporal covariation and the correlation between the FMPS and ELPI is good. The advantage of the FMPS is the excellent time- and size resolution of the results. The main advantage of the ELPI is the possibility to collect size-fractionated samples of the dust for subsequent analysis by, for example, electron microscopy. The CPC does not provide information about the particle size distribution and its correlation to the other two instruments is somewhat poor. Nonetheless, the CPC gives basic, real-time information about the ultrafine particle concentration and can therefore be used for source identification. PMID:27598180

  18. Receptor modeling of globally circulating airborne particles collected at Mauna Loa Observatory, Hawaii

    SciTech Connect

    Hermann, D.M.

    1988-01-01

    Weekly airborne particle samples were collected at Mauna Loa Observatory (MLO), Hawaii from February 1979 through May 1985. Receptor models were used to identify sources of airborne particles at MLO, determine compositions of particles from these sources, and assess the relative impacts of them. Major sources of ambient particles at MLO include Asian continental material, oceanic biological production of Se and SO{sub 4} species, marine particles, Asian anthropogenic material, local volcanic emissions, and basalt. Source composition profiles were developed for each component. The Asian continental component represents particles transported from Eastern Asia to the North Pacific, and the component consists of crustal material contaminated by anthropogenic emissions. To account for variations in the relative strengths of anthropogenic and crustal sources, a separate Asian anthropogenic component was also developed. During the dust season, Asian continental material accounts for 80% of total suspended particulate material (TSP) at MLO, oceanic productions of Se and SO{sub 4} 11%, marine particles 2.8%, basalt 1.9%, volcanic emissions 1.7%, and Asian anthropogenic material in excess of Asian continental material 3.2%. During the clean season, the oceanic biological production of Se and SO{sub 4} contributes 62% of TSP at MLO. Continental material contributes 22%, marine particles 6.4%, basalt 2.7%, volcanic emissions 2.4%, and anthropogenic materials in excess of continental material 4.3%.

  19. THEORETICAL MODEL OF SOILING OF SURFACES BY AIRBORNE PARTICLES

    EPA Science Inventory

    A model is developed which can be used to predict the change in reflectance from a surface as a function of time. Reflectance change is a measure of soiling caused by the deposition of particles on a surface. The major inputs to the model are the parameters to a bimodal distribut...

  20. Sensitivity of airborne fluorosensor measurements to linear vertical gradients in chlorophyll concentration

    NASA Technical Reports Server (NTRS)

    Venable, D. D.; Punjabi, A. R.; Poole, L. R.

    1984-01-01

    A semianalytic Monte Carlo radiative transfer simulation model for airborne laser fluorosensors has been extended to investigate the effects of inhomogeneities in the vertical distribution of phytoplankton concentrations in clear seawater. Simulation results for linearly varying step concentrations of chlorophyll are presented. The results indicate that statistically significant differences can be seen under certain conditions in the water Raman-normalized fluorescence signals between nonhomogeneous and homogeneous cases. A statistical test has been used to establish ranges of surface concentrations and/or verticl gradients in which calibration by surface samples would by inappropriate, and the results are discussed.

  1. Device and method for accurately measuring concentrations of airborne transuranic isotopes

    DOEpatents

    McIsaac, Charles V.; Killian, E. Wayne; Grafwallner, Ervin G.; Kynaston, Ronnie L.; Johnson, Larry O.; Randolph, Peter D.

    1996-01-01

    An alpha continuous air monitor (CAM) with two silicon alpha detectors and three sample collection filters is described. This alpha CAM design provides continuous sampling and also measures the cumulative transuranic (TRU), i.e., plutonium and americium, activity on the filter, and thus provides a more accurate measurement of airborne TRU concentrations than can be accomplished using a single fixed sample collection filter and a single silicon alpha detector.

  2. Determining Airborne Concentrations of Spatial Repellent Chemicals in Mosquito Behavior Assay Systems

    PubMed Central

    Martin, Nicholas J.; Smith, Philip A.; Achee, Nicole L.; DeLong, Gerald T.

    2013-01-01

    Background Mosquito behavior assays have been used to evaluate the efficacy of vector control interventions to include spatial repellents (SR). Current analytical methods are not optimized to determine short duration concentrations of SR active ingredients (AI) in air spaces during entomological evaluations. The aim of this study was to expand on our previous research to further validate a novel air sampling method to detect and quantitate airborne concentrations of a SR under laboratory and field conditions. Methodology/Principal Findings A thermal desorption (TD) gas chromatography-mass spectrometry (GC-MS) method was used to determine the amount of dichlorodiphenyltrichloroethane (DDT) in samples of air. During laboratory experiments, 1 L volumes of air were collected over 10 min intervals from a three-chamber mosquito behavior assay system. Significantly higher levels of airborne DDT were measured in the chamber containing textiles treated with DDT compared to chambers free of AI. In the field, 57 samples of air were collected from experimental huts with and without DDT for onsite analysis. Airborne DDT was detected in samples collected from treated huts. The mean DDT air concentrations in these two huts over a period of four days with variable ambient temperature were 0.74 µg/m3 (n = 17; SD = 0.45) and 1.42 µg/m3 (n = 30; SD = 0.96). Conclusions/Significance The results from laboratory experiments confirmed that significantly different DDT exposure conditions existed in the three-chamber system establishing a chemical gradient to evaluate mosquito deterrency. The TD GC-MS method addresses a need to measure short-term (<1 h) SR concentrations in small volume (<100 L) samples of air and should be considered for standard evaluation of airborne AI levels in mosquito behavior assay systems. Future studies include the use of TD GC-MS to measure other semi-volatile vector control compounds. PMID:24015195

  3. Device and method for accurately measuring concentrations of airborne transuranic isotopes

    DOEpatents

    McIsaac, C.V.; Killian, E.W.; Grafwallner, E.G.; Kynaston, R.L.; Johnson, L.O.; Randolph, P.D.

    1996-09-03

    An alpha continuous air monitor (CAM) with two silicon alpha detectors and three sample collection filters is described. This alpha CAM design provides continuous sampling and also measures the cumulative transuranic (TRU), i.e., plutonium and americium, activity on the filter, and thus provides a more accurate measurement of airborne TRU concentrations than can be accomplished using a single fixed sample collection filter and a single silicon alpha detector. 7 figs.

  4. Genotoxicity of organic extracts of airborne particles in somatic cells of Drosophila melanogaster.

    PubMed

    Delgado-Rodríguez, A; Ortíz-Marttelo, R; Villalobos-Pietrini, R; Gómez-Arroyo, S; Graf, U

    1999-07-01

    Complex mixtures extracted from air filters exposed for 24 h in two sessions (27 July and 02 August 1991) and at two locations (Merced, downtown, and Pedregal de San Angel, south-west) in Mexico City were analysed. The organic extracts were from airborne particles equal or smaller than 10 microns (PM10), and from total suspended particles (TSP). These organic extracts were assayed in the somatic mutation and recombination test (SMART) in wings of Drosophila melanogaster using two different crosses as well as in the Salmonella/microsome assay using strain TA98 with and without S9 fraction. The presence of polycyclic aromatic hydrocarbons (PAH) in the extracts was determined by gas chromatography. The genotoxic activities observed in the two test systems were comparable with the indirect mutagens producing greater response than the direct mutagens. The quantities of particulate matter as well as the genotoxic activities were higher on 02 August than on 27 July 1991 for both locations. The amounts of airborne particles and the resulting genotoxic activities were higher at Merced than at Pedregal. In both biological systems, PM10 were more genotoxic than TSP. These results demonstrate the sensitivity of the Drosophila wing SMART-which is an in vivo eukaryotic genotoxicity assay-as a biological monitor of environmental pollution related to airborne particles. PMID:10377966

  5. Airborne Particulate Matter in Two Multi-Family Green Buildings: Concentrations and Effect of Ventilation and Occupant Behavior

    PubMed Central

    Patton, Allison P.; Calderon, Leonardo; Xiong, Youyou; Wang, Zuocheng; Senick, Jennifer; Sorensen Allacci, MaryAnn; Plotnik, Deborah; Wener, Richard; Andrews, Clinton J.; Krogmann, Uta; Mainelis, Gediminas

    2016-01-01

    There are limited data on air quality parameters, including airborne particulate matter (PM) in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1) measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E) and mechanical (Building L) ventilation; (2) compare indoor and outdoor PM mass concentrations and their ratios (I/O) in these buildings, taking into account the effects of occupant behavior; and (3) evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m3) than in Building L (37 µg/m3); I/O was higher in Building E (1.3–2.0) than in Building L (0.5–0.8) for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation) are important factors affecting residents’ exposure to PM in residential green buildings. PMID:26805862

  6. Airborne Particulate Matter in Two Multi-Family Green Buildings: Concentrations and Effect of Ventilation and Occupant Behavior.

    PubMed

    Patton, Allison P; Calderon, Leonardo; Xiong, Youyou; Wang, Zuocheng; Senick, Jennifer; Sorensen Allacci, MaryAnn; Plotnik, Deborah; Wener, Richard; Andrews, Clinton J; Krogmann, Uta; Mainelis, Gediminas

    2016-01-01

    There are limited data on air quality parameters, including airborne particulate matter (PM) in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1) measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E) and mechanical (Building L) ventilation; (2) compare indoor and outdoor PM mass concentrations and their ratios (I/O) in these buildings, taking into account the effects of occupant behavior; and (3) evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m³) than in Building L (37 µg/m³); I/O was higher in Building E (1.3-2.0) than in Building L (0.5-0.8) for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation) are important factors affecting residents' exposure to PM in residential green buildings. PMID:26805862

  7. [The airborne 1,3-butadiene concentrations in rubber and plastic processing plants].

    PubMed

    Yoshida, Toshiaki; Tainaka, Hidetsugu; Matsunaga, Ichiro; Goto, Sumio

    2002-03-01

    Environment pollution by 1,3-butadiene had considerably increased in Japan. The main cause of the pollution is the automotive exhaust gas, and leaks from factories, smoking, and burning of rubber and plastic products are considered to be minor sources. The object of this study was to determine the contamination levels of airborne 1,3-butadiene in factories processing rubber and plastics containing 1,3-butadiene. The concentrations of airborne 1,3-butadiene were measured in 21 plants (10 rubber processing plants and 11 plastics processing plants) in Osaka. 1,3-Butadiene in air was collected for 10 minutes with a charcoal tube and a portable small pump adjusted to a 250 ml/min flow rate. In each plant, indoor air samples at five points and an outdoor air sample at one point outside the plant were collected. The samples were subjected to gas chromatography/mass spectrometry after thermal desorption from the charcoal. The concentrations of airborne 1,3-butadiene in the rubber processing plants and the plastics processing plants were 0.14-2.20 micrograms/m3 (geometric mean: 0.48 microgram/m3) and 0.23-4.51 micrograms/m3 (geometric mean: 0.80 microgram/m3), respectively. In all plants examined, indoor 1,3-butadiene concentrations were higher than the outdoor concentrations around the plants. Therefore, 1,3-butadiene was considered to arise from the processing of rubber or plastics, but the indoor 1,3-butadiene concentrations were much lower than the PEL-TWA (1 ppm = 2.21 mg/m3) of OSHA and the TLV-TWA (2 ppm) of ACGIH. The concentrations in the plants with closed room conditions without ventilation were higher than the concentrations in the other plants. It was suggested that ventilation affected the 1,3-butadiene concentration in the plants. PMID:11993233

  8. Non-Seasonal Variation of Airborne Aspergillus Spore Concentration in a Hospital Building.

    PubMed

    Oberle, Michael; Reichmuth, Markus; Laffer, Reto; Ottiger, Cornelia; Fankhauser, Hans; Bregenzer, Thomas

    2015-11-01

    Nosocomial fungal infections are gaining increased attention from infectiologists. An adequate investigation into the levels of airborne Aspergillus and other fungal spores in hospital settings, under normal conditions, is largely unknown. We monitored airborne spore contamination in a Swiss hospital building in order to establish a seasonally-dependent base-line level. Air was sampled using an impaction technique, twice weekly, at six different locations over one year. Specimens were seeded in duplicate on Sabouraud agar plates. Grown colonies were identified to genus levels. The airborne Aspergillus spore concentration was constantly low throughout the whole year, at a median level of 2 spores/m³ (inter-quartile range = IQR 1-4), and displayed no seasonal dependency. The median concentration of other fungal spores was higher and showed a distinct seasonal variability with the ambient temperature change during the different seasons: 82 spores/m³ (IQR 26-126) in summer and 9 spores/m³ (IQR 6-15) in winter. The spore concentration varied considerably between the six sampling sites in the building (10 to 26 spores/m³). This variability may explain the variability of study results in the literature. PMID:26516890

  9. Non-Seasonal Variation of Airborne Aspergillus Spore Concentration in a Hospital Building

    PubMed Central

    Oberle, Michael; Reichmuth, Markus; Laffer, Reto; Ottiger, Cornelia; Fankhauser, Hans; Bregenzer, Thomas

    2015-01-01

    Nosocomial fungal infections are gaining increased attention from infectiologists. An adequate investigation into the levels of airborne Aspergillus and other fungal spores in hospital settings, under normal conditions, is largely unknown. We monitored airborne spore contamination in a Swiss hospital building in order to establish a seasonally-dependent base-line level. Air was sampled using an impaction technique, twice weekly, at six different locations over one year. Specimens were seeded in duplicate on Sabouraud agar plates. Grown colonies were identified to genus levels. The airborne Aspergillus spore concentration was constantly low throughout the whole year, at a median level of 2 spores/m3 (inter-quartile range = IQR 1–4), and displayed no seasonal dependency. The median concentration of other fungal spores was higher and showed a distinct seasonal variability with the ambient temperature change during the different seasons: 82 spores/m3 (IQR 26–126) in summer and 9 spores/m3 (IQR 6–15) in winter. The spore concentration varied considerably between the six sampling sites in the building (10 to 26 spores/m3). This variability may explain the variability of study results in the literature. PMID:26516890

  10. Simultaneous light scattering and intrinsic fluorescence measurement for the classification of airborne particles.

    PubMed

    Kaye, P H; Barton, J E; Hirst, E; Clark, J M

    2000-07-20

    We describe a prototype laboratory light-scattering instrument that integrates two approaches to airborne particle characterization: spatial light-scattering analysis and intrinsic fluorescence measurement, with the aim of providing an effective means of classifying biological particles within an ambient aerosol. The system uses a single continuous-wave 266-nm ultraviolet laser to generate both the spatial elastic scatter data (from which an assessment of particle size and shape is made) and the particle intrinsic fluorescence data from particles in the approximate size range of 1-10-mum diameter carried in a sample airflow through the laser beam. Preliminary results suggest that this multiparameter measurement approach can provide an effective means of classifying different particle types and can reduce occurrences of false-positive detection of biological aerosols. PMID:18349949

  11. Identification and characterization of individual airborne volcanic ash particles by Raman microspectroscopy.

    PubMed

    Ivleva, Natalia P; Huckele, Susanne; Weinzierl, Bernadett; Niessner, Reinhard; Haisch, Christoph; Baumann, Thomas

    2013-11-01

    We present for the first time the Raman microspectroscopic identification and characterization of individual airborne volcanic ash (VA) particles. The particles were collected in April/May 2010 during research aircraft flights, which were performed by Deutsches Zentrum für Luft- und Raumfahrt in the airspace near the Eyjafjallajökull volcano eruption and over Europe (between Iceland and Southern Germany). In addition, aerosol particles were sampled by an Electrical Low Pressure Impactor in Munich, Germany. As references for the Raman analysis, we used the spectra of VA collected at the ground near the place of eruption, of mineral basaltic rock, and of different minerals from a database. We found significant differences in the spectra of VA and other aerosol particles (e.g., soot, nitrates, sulfates, and clay minerals), which allowed us to identify VA among other atmospheric particulate matter. Furthermore, while the airborne VA shows a characteristic Raman pattern (with broad band from ca. 200 to ca. 700 cm(-1) typical for SiO₂ glasses and additional bands of ferric minerals), the differences between the spectra of aged and fresh particles were observed, suggesting differences in their chemical composition and/or structure. We also analyzed similarities between Eyjafjallajökull VA particles collected at different sampling sites and compared the particles with a large variety of glassy and crystalline minerals. This was done by applying cluster analysis, in order to get information on the composition and structure of volcanic ash. PMID:24121468

  12. Predicting Airborne Particle Levels Aboard Washington State School Buses

    PubMed Central

    Adar, Sara D.; Davey, Mark; Sullivan, James R.; Compher, Michael; Szpiro, Adam; Liu, L.-J. Sally

    2008-01-01

    School buses contribute substantially to childhood air pollution exposures yet they are rarely quantified in epidemiology studies. This paper characterizes fine particulate matter (PM2.5) aboard school buses as part of a larger study examining the respiratory health impacts of emission-reducing retrofits. To assess onboard concentrations, continuous PM2.5 data were collected during 85 trips aboard 43 school buses during normal driving routines, and aboard hybrid lead vehicles traveling in front of the monitored buses during 46 trips. Ordinary and partial least square regression models for PM2.5 onboard buses were created with and without control for roadway concentrations, which were also modeled. Predictors examined included ambient PM2.5 levels, ambient weather, and bus and route characteristics. Concentrations aboard school buses (21 μg/m3) were four and two-times higher than ambient and roadway levels, respectively. Differences in PM2.5 levels between the buses and lead vehicles indicated an average of 7 μg/m3 originating from the bus's own emission sources. While roadway concentrations were dominated by ambient PM2.5, bus concentrations were influenced by bus age, diesel oxidative catalysts, and roadway concentrations. Cross validation confirmed the roadway models but the bus models were less robust. These results confirm that children are exposed to air pollution from the bus and other roadway traffic while riding school buses. In-cabin air pollution is higher than roadway concentrations and is likely influenced by bus characteristics. PMID:18985175

  13. Deriving the concentration of airborne ash with a CAS-DPOL instrument: assessing uncertainties introduced by the instrument design

    NASA Astrophysics Data System (ADS)

    Spanu, Antonio; Weinzierl, Bernadett; Freudenthaler, Volker; Sauer, Daniel; Gasteiger, Josef

    2016-04-01

    Explosive volcanic eruptions inject large amounts of gas and particles into the atmosphere resulting in strong impacts on anthropic systems and climate. Fine ash particles in suspension, even if at low concentrations, are a serious aviation safety hazard. A key point to predict the dispersion and deposition of volcanic ash is the knowledge of emitted mass and its particle size distribution. Usually the deposit is used to characterize the source but a large uncertainty is present for fine and very fine ash particles which are usually not well preserved. Conversely, satellite observations provide only column-integrated information and are strongly sensitive to cloud conditions above the ash plumes. Consequently, in situ measurements are fundamental to extend our knowledge on ash clouds, their properties, and interactions over the vertical extent of the atmosphere. Different in-situ instruments are available covering different particle size ranges using a variety of measurement techniques. Depending on the measurement technique, artefacts due to instrument setup and ambient conditions can strongly modify the measured number concentration and size distribution of the airborne particles. It is fundamental to correct for those effects to quantify the uncertainty associated with the measurement. Here we evaluate the potential of our optical light-scattering spectrometer CAS-DPOL to detect airborne mineral dust and volcanic ash (in the size range between 0.7μm and 50μm) and to provide a reliable estimation of the mass concentration, investigating the associate uncertainty. The CAS-DPOL instrument sizes particles by detecting the light scattered off the particle into a defined angle. The associated uncertainty depends on the optical instrument design and on unknown particles characteristics such as shape and material. Indirect measurements of mass concentrations are statistically reconstructed using the air flow velocity. Therefore, the detected concentration is strongly

  14. Measurements of condensation nuclei in the Airborne Arctic Stratospheric Expedition: Observations of particle production in the polar vortex

    SciTech Connect

    Wilson, J.C.; Stolzenburg, M.R. ); Clark, W.E. ); Loewenstein, M.; Ferry, G.V.; Chan, K.R. )

    1990-03-01

    The ER-2 Condensation Nucleus Counter (ER-2 CNC) was operated in the Airborne Arctic Stratospheric Expedition (AASE) in January and February 1989. The ER-2 CNC measures the mixing ratio of particles, CN, with diameters from approximately 0.02 {mu}m to approximately 1 {mu}m. The spatial distribution of CN in the Arctic polar vortex was found to resemble that measured in the Antarctic in the Spring of 1987. The vertical profile of CN in the vortex was lowered by subsidence. At altitudes above the minimum in the CN mixing ratio profile, CN mixing ratios correlated negatively with that of N{sub 2}O, demonstrating new particle production. CN serve as nuclei in the formation of Polar Stratospheric Clouds (PSC's) and the concentration of CN can affect PSC properties.

  15. Measurements of condensation nuclei in the Airborne Arctic Stratospheric Expedition - Observations of particle production in the polar vortex

    NASA Technical Reports Server (NTRS)

    Wilson, J. C.; Stolzenburg, M. R.; Clark, W. E.; Loewenstein, M.; Ferry, G. V.; Chan, K. R.

    1990-01-01

    The ER-2 Condensation Nucleus Counter (ER-2 CNC) was operated in the Airborne Arctic Stratospheric Expedition (AASE) in January and February 1989. The ER-2 CNC measures the mixing ratio of particles, CN, with diameters from approximately 0.02 to approximately 1 micron. The spatial distribution of CN in the Arctic polar vortex was found to resemble that measured in the Antarctic in the Spring of 1987. The vertical profile of CN in the vortex was lowered by subsidence. At altitudes above the minimum in the CN mixing ratio profile, CN mixing ratios correlated negatively with that of N2O, demonstrating new particle production. CN serve as nuclei in the formation of Polar Stratospheric Clouds (PSCs) and the concentration of CN can affect PSC properties.

  16. Possible evidence of new particle formation and its impact on cloud microphysics from airborne measurements over Bay of Bengal

    NASA Astrophysics Data System (ADS)

    Deshpande, C. G.; Bhalwankar, Rohini; Padmakumari, B.; Maheskumar, R. S.; Axisa, Duncan; Kulkarni, J. R.

    2014-04-01

    Airborne measurements conducted under a special mission over Bay of Bengal (BoB) during the CAIPEEX (Cloud Aerosol Interaction and Precipitation Enhancement EXperiment) in 2011 were analyzed in the present study. Research flights were carried out on 19 and 20 October, 2011 (referred as RF1 and RF2), in the region over BoB, which was influenced by a depression to evaluate the aerosol-cloud interactions over marine environment. The increased concentration of aitken/accumulation mode particles was observed at 500 m above sea surface level over the ocean after the passage of the depression. The source of these particles and their subsequent growth during RF1 at about 200 km from coastline has been attributed to (i) increased production of aerosols due to oxidation of dimethyl sulfide (DMS) because of upwelling of the deep ocean water during the depression and (ii) anthropogenic aerosols transported from inland. Moreover, measurements of accumulation and coarse mode particles with diameter ranging from 0.1 to 3 μm and cloud droplets in the range 3 to 47 μm show systematic growth associated with cloud microphysical/rain formation process. On the other hand, no such evidence of increasing particle concentration and growth has been observed at about 60 km from coastline towards southeast during RF2. Evidently, the rain event observed during the night hours of 19 October caused the washout and scavenging of aerosols which contributed towards the decreased aerosol concentration observed near the coast.

  17. Setting Spacecraft Maximum Allowable Concentrations for 1 hour or 24 hour contingency exposures to airborne chemicals

    NASA Technical Reports Server (NTRS)

    Garcia, Hector D.; Limero, Thomas F.; James, John T.

    1992-01-01

    Since the early years of the manned space program, NASA has developed and used exposure limits called Spacecraft Maximum Allowable Concentrations (SMACs) to help protect astronauts from airborne toxicants. Most of these SMACS are based on an exposure duration of 7 days, since this is the duration of a 'typical' mission. A set of 'contingency SMACs' is also being developed for scenarios involving brief (1-hour or 24- hour) exposures to relatively high levels of airborne toxicants from event-related 'contingency' releases of contaminants. The emergency nature of contingency exposures dictates the use of different criteria for setting exposure limits. The NASA JSC Toxicology Group recently began a program to document the rationales used to set new SMACs and plans to review the older, 7-day SMACs. In cooperation with the National Research Council's Committee on Toxicology, a standard procedure has been developed for researching, setting, and documenting SMAC values.

  18. Investigation of fluorine content in PM2.5 airborne particles of Istanbul, Turkey.

    PubMed

    Ozbek, Nil; Baltaci, Hakki; Baysal, Asli

    2016-07-01

    Fluorine determination in airborne samples is important due to its spread into the air from both natural and artificial sources. It can travel by wind over large distances before depositing on the Earth's surface. Its concentration in various matrices are limited and controlled by the regulations for causing health risks associated with environmental exposures. In this work, fluorine was determined in PM2.5 airborne samples by high-resolution continuum source electrothermal atomic absorption spectrometry. For these purpose, the PM2.5 airborne particulates were collected on quartz filters using high-volume samplers (500 L/min) in Istanbul (Turkey) for 96 h during January to June in 2 years. Then, instrumental and experimental parameters were optimized for the analyte in airborne samples. The validity of the method for the analyte was tested using standard reference material, and certified values were found in the limits of 95 % confidence level. The fluorine concentrations and meteorological conditions were compared statistically. PMID:27023803

  19. Application of traditional cyclone with spray scrubber to remove airborne silica particles emitted from stone-crushing factories.

    PubMed

    Bahrami, Abdulrahman; Ghorbani, Farshid; Mahjub, Hossien; Golbabei, Farideh; Aliabadi, Mohsan

    2009-08-01

    The traditional cyclone with spray scrubber was developed for the removal of airborne silica particles from local exhaust ventilation (LEV). The objective of this research is to evaluate the efficiency of this process for removing silica particles in LEV. After designing and installing a traditional cyclone and spray scrubber, air samples were obtained at the inlet and outlet of the apparatus. The mass of each collected sample was determined gravimetrically using EPA method. The efficiency of the cyclone with spray scrubber for the removal of dust particles from the LEV system was determined to be in the range of 92-99%. There was a high correlation between the inlet concentration of dust particles and the efficiency of the apparatus. The total pressure across the system was 772.17-1120.90 Pa. It was concluded that a traditional cyclone with a spray scrubber can effectively remove a very high percentage of the incoming silica particles from an LEV. The total pressure drop across the current process is less than the pressure drop across other treatment equipment, which means that our process can effectively remove silica particles while using less electricity than other processes. PMID:19672019

  20. Vertical distribution of aerosol number concentration in the troposphere over Siberia derived from airborne in-situ measurements

    NASA Astrophysics Data System (ADS)

    Arshinov, Mikhail Yu.; Belan, Boris D.; Paris, Jean-Daniel; Machida, Toshinobu; Kozlov, Alexandr; Malyskin, Sergei; Simonenkov, Denis; Davydov, Denis; Fofonov, Alexandr

    2016-04-01

    Knowledge of the vertical distribution of aerosols particles is very important when estimating aerosol radiative effects. To date there are a lot of research programs aimed to study aerosol vertical distribution, but only a few ones exist in such insufficiently explored region as Siberia. Monthly research flights and several extensive airborne campaigns carried out in recent years in Siberian troposphere allowed the vertical distribution of aerosol number concentration to be summarized. In-situ aerosol measurements were performed in a wide range of particle sizes by means of improved version of the Novosibirsk-type diffusional particle sizer and GRIMM aerosol spectrometer Model 1.109. The data on aerosol vertical distribution enabled input parameters for the empirical equation of Jaenicke (1993) to be derived for Siberian troposphere up to 7 km. Vertical distributions of aerosol number concentration in different size ranges averaged for the main seasons of the year will be presented. This work was supported by Interdisciplinary integration projects of the Siberian Branch of the Russian Academy of Science No. 35, No. 70 and No. 131; the Branch of Geology, Geophysics and Mining Sciences of RAS (Program No. 5); and Russian Foundation for Basic Research (grant No. 14-05-00526). Jaenicke R. Tropospheric aerosols, in Aerosol-Cloud-Climate Interactions, edited by P.V. Hobs. -Academic Press, San Diego, CA, 1993.- P. 1-31.

  1. Optimization of the concentration optics of the Martian airborne dust sensor for MetNet space mission

    NASA Astrophysics Data System (ADS)

    Cortés, F.; González, A.; de Castro, A. J.; López, F.

    2012-06-01

    Martian atmosphere contains a significant and rapidly changing load of suspended dust that never drops to zero. The main component of Martian aerosol is micron-sized dust thought to be a product of soil weathering. Although airborne dust plays a key role in Martian climate, the basic physical properties of these aerosols are still poorly known. The scope of Mars MetNet Mission is to deploy several tens of mini atmospheric stations on the Martian surface. MEIGA-MetNet payload is the Spanish contribution in MetNet. Infrared Laboratory of University Carlos III (LIR-UC3M) is in charge of the design and development of a micro-sensor for the characterization of airborne dust. This design must accomplish with a strict budget of mass and power, 45 g and 1 W respectively. The sensor design criteria have been obtained from a physical model specifically developed for optimizing IR local scattering. The model calculates the spectral power density scattered and detected between 1 and 5 μm by a certain particle distribution and sensor configuration. From model calculations a modification based on the insertion of a compound ellipsoidal concentrator (CEC) has appeared as necessary. Its implementation has multiplied up to 100 the scattered optical power detected, significantly enhancing the detection limits of the sensor.

  2. Airborne concentrations of benzene associated with the historical use of some formulations of liquid wrench.

    PubMed

    Williams, Pamela R D; Knutsen, Jeffrey S; Atkinson, Chris; Madl, Amy K; Paustenbach, Dennis J

    2007-08-01

    The current study characterizes potential inhalation exposures to benzene associated with the historical use of some formulations of Liquid Wrench under specific test conditions. This product is a multiuse penetrant and lubricant commonly used in a variety of consumer and industrial settings. The study entailed the remanufacturing of several product formulations to have similar physical and chemical properties to most nonaerosol Liquid Wrench formulations between 1960 and 1978. The airborne concentrations of benzene and other constituents during the simulated application of these products were measured under a range of conditions. Nearly 200 breathing zone and area bystander air samples were collected during 11 different product use scenarios. Depending on the tests performed, average airborne concentrations of benzene ranged from approximately 0.2-9.9 mg/m(3) (0.08-3.8 ppm) for the 15-min personal samples; 0.1-8 mg/m(3) (0.04-3 ppm) for the 1-hr personal samples; and 0.1-5.1 mg/m(3) (0.04-2 ppm) for the 1-hr area samples. The 1-hr personal samples encompassed two 15-min product applications and two 15-min periods of standing within 5 to 10 feet of the work area. The measured airborne concentrations of benzene varied significantly based on the benzene content of the formulation tested (1%, 3%, 14%, or 30% v/v benzene) and the indoor air exchange rate but did not vary much with the base formulation of the product or the two quantities of Liquid Wrench used. The airborne concentrations of five other volatile chemicals (ethylbenzene, toluene, total xylenes, cyclohexane, and hexane) were also measured, and the results were consistent with the volatility and concentrations of these chemicals in the product tested. A linear regression analysis of air concentration compared with the chemical mole fraction in the solution and air exchange rate provided a relatively good fit to the data. The results of this study should be useful for evaluating potential inhalation

  3. Crop harvest in Central Europe causes episodes of high airborne Alternaria spore concentrations in Copenhagen

    NASA Astrophysics Data System (ADS)

    Skjøth, C. A.; Sommer, J.; Frederiksen, L.; Gosewinkel Karlson, U.

    2012-06-01

    This study tests the hypothesis that Danish agricultural areas are the main source to airborne Alternaria spores in Copenhagen, Denmark. We suggest that the source to the overall load is mainly local, but with intermittent Long Distance Transport (LDT) from more remote agricultural areas. This hypothesis is supported by investigating a 10 yr bi-hourly record of Alternaria spores in the air from Copenhagen. This record shows 232 clinically relevant episodes with a distinct daily profile. The data analysis also revealed potential LDT episodes almost every year. A source map and analysis of atmospheric transport suggest that LDT always originates from the main agricultural areas in Central Europe. A dedicated emission study in cereal crops under harvest during 2010 also supports our hypothesis. The emission study showed that although the fields had been treated against fungal infections, harvesting still produced large amounts of airborne fungal spores. It is likely that such harvesting periods can cause clinically relevant levels of fungal spores in the atmosphere. Our findings suggest that crop harvest in Central Europe causes episodes of high airborne Alternaria spore concentrations in Copenhagen as well as other urban areas in this region. It is likely that such episodes could be simulated using atmospheric transport models.

  4. Comparison of deposited surface area of airborne ultrafine particles generated from two welding processes.

    PubMed

    Gomes, J F; Albuquerque, P C; Miranda, Rosa M; Santos, Telmo G; Vieira, M T

    2012-09-01

    This article describes work performed on the assessment of the levels of airborne ultrafine particles emitted in two welding processes metal-active gas (MAG) of carbon steel and friction-stir welding (FSW) of aluminium in terms of deposited area in alveolar tract of the lung using a nanoparticle surface area monitor analyser. The obtained results showed the dependence from process parameters on emitted ultrafine particles and clearly demonstrated the presence of ultrafine particles, when compared with background levels. The obtained results showed that the process that results on the lower levels of alveolar-deposited surface area is FSW, unlike MAG. Nevertheless, all the tested processes resulted in important doses of ultrafine particles that are to be deposited in the human lung of exposed workers. PMID:22954401

  5. A Novel Size-Selective Airborne Particle Sampling Instrument (Wras) for Health Risk Evaluation

    NASA Astrophysics Data System (ADS)

    Gnewuch, H.; Muir, R.; Gorbunov, B.; Priest, N. D.; Jackson, P. R.

    Health risks associated with inhalation of airborne particles are known to be influenced by particle sizes. A reliable, size resolving sampler, classifying particles in size ranges from 2 nm—30 μm and suitable for use in the field would be beneficial in investigating health risks associated with inhalation of airborne particles. A review of current aerosol samplers highlighted a number of limitations. These could be overcome by combining an inertial deposition impactor with a diffusion collector in a single device. The instrument was designed for analysing mass size distributions. Calibration was carried out using a number of recognised techniques. The instrument was tested in the field by collecting size resolved samples of lead containing aerosols present at workplaces in factories producing crystal glass. The mass deposited on each substrate proved sufficient to be detected and measured using atomic absorption spectroscopy. Mass size distributions of lead were produced and the proportion of lead present in the aerosol nanofraction calculated and varied from 10% to 70% by weight.

  6. Analysing the health effects of simultaneous exposure to physical and chemical properties of airborne particles

    PubMed Central

    Pirani, Monica; Best, Nicky; Blangiardo, Marta; Liverani, Silvia; Atkinson, Richard W.; Fuller, Gary W.

    2015-01-01

    Background Airborne particles are a complex mix of organic and inorganic compounds, with a range of physical and chemical properties. Estimation of how simultaneous exposure to air particles affects the risk of adverse health response represents a challenge for scientific research and air quality management. In this paper, we present a Bayesian approach that can tackle this problem within the framework of time series analysis. Methods We used Dirichlet process mixture models to cluster time points with similar multipollutant and response profiles, while adjusting for seasonal cycles, trends and temporal components. Inference was carried out via Markov Chain Monte Carlo methods. We illustrated our approach using daily data of a range of particle metrics and respiratory mortality for London (UK) 2002–2005. To better quantify the average health impact of these particles, we measured the same set of metrics in 2012, and we computed and compared the posterior predictive distributions of mortality under the exposure scenario in 2012 vs 2005. Results The model resulted in a partition of the days into three clusters. We found a relative risk of 1.02 (95% credible intervals (CI): 1.00, 1.04) for respiratory mortality associated with days characterised by high posterior estimates of non-primary particles, especially nitrate and sulphate. We found a consistent reduction in the airborne particles in 2012 vs 2005 and the analysis of the posterior predictive distributions of respiratory mortality suggested an average annual decrease of − 3.5% (95% CI: − 0.12%, − 5.74%). Conclusions We proposed an effective approach that enabled the better understanding of hidden structures in multipollutant health effects within time series analysis. It allowed the identification of exposure metrics associated with respiratory mortality and provided a tool to assess the changes in health effects from various policies to control the ambient particle matter mixtures. PMID:25795926

  7. COLLECTION OF AIRBORNE PARTICLES BY A HIGH-GRADIENT PERMANENT MAGNETIC METHOD

    SciTech Connect

    Cheng, Mengdawn; Allman, Steve L; Ludtka, Gerard Michael; Avens, Larry R

    2014-01-01

    We report on the use of magnetic force in collection of airborne particles by a high- gradient permanent magnetic separation (HGPMS) device. Three aerosol particles of different magnetic susceptibility (NaCl, CuO, and Fe2O3) were generated in the electrical mobility size range of 10 to 200 nm and were used to study HGPMS collection. One HGPMS matrix element, made of stainless steel wool, was used in the device configuration. Three flow rates were selected to simulate the environmental wind speeds of interest to the study. Magnetic force was found to exhibit an insignificant effect on the separation of NaCl particles, even in the HGPMS configuration. Diffusion was a major mechanism in the removal of the diamagnetic particles; however, diffusion is insignificant under the influence of a high-gradient magnetic field for paramagnetic or ferromagnetic particles. The HGPMS showed high-performance collection (> 99%) of paramagnetic CuO and ferromagnetic Fe2O3 particles for particle sizes greater than or equal to 60 nm. As the wind speed increases, the influence of the magnetic force weakens, and the capability to remove particles from the gas stream diminishes. The results suggest that the HGPMS principle could be explored for development of an advanced miniaturized passive aerosol collector.

  8. Inactivation of Airborne Bacteria and Viruses Using Extremely Low Concentrations of Chlorine Dioxide Gas.

    PubMed

    Ogata, Norio; Sakasegawa, Miyusse; Miura, Takanori; Shibata, Takashi; Takigawa, Yasuhiro; Taura, Kouichi; Taguchi, Kazuhiko; Matsubara, Kazuki; Nakahara, Kouichi; Kato, Daisuke; Sogawa, Koushirou; Oka, Hiroshi

    2016-01-01

    Infectious airborne microbes, including many pathological microbes that cause respiratory infections, are commonly found in medical facilities and constitute a serious threat to human health. Thus, an effective method for reducing the number of microbes floating in the air will aid in the minimization of the incidence of respiratory infectious diseases. Here, we demonstrate that chlorine dioxide (ClO2) gas at extremely low concentrations, which has no detrimental effects on human health, elicits a strong effect to inactivate bacteria and viruses and significantly reduces the number of viable airborne microbes in a hospital operating room. In one set of experiments, a suspension of Staphylococcus aureus, bacteriophage MS2, and bacteriophage ΦX174 were released into an exposure chamber. When ClO2 gas at 0.01 or 0.02 parts per million (ppm, volume/volume) was present in the chamber, the numbers of surviving microbes in the air were markedly reduced after 120 min. The reductions were markedly greater than the natural reductions of the microbes in the chamber. In another experiment, the numbers of viable airborne bacteria in the operating room of a hospital collected over a 24-hour period in the presence or absence of 0.03 ppm ClO2 gas were found to be 10.9 ± 6.7 and 66.8 ± 31.2 colony-forming units/m3 (n = 9, p < 0.001), respectively. Taken together, we conclude that ClO2 gas at extremely low concentrations (≤0.03 ppm) can reduce the number of viable microbes floating in the air in a room. These results strongly support the potential use of ClO2 gas at a non-toxic level to reduce infections caused by the inhalation of pathogenic microbes in nursing homes and medical facilities. PMID:26926704

  9. Performance of photocatalytic lamps on reduction of culturable airborne microorganism concentration.

    PubMed

    Chuaybamroong, Paradee; Thunyasirinon, Chuleewan; Supothina, Sitthisuntorn; Sribenjalux, Pipat; Wu, Chang-Yu

    2011-04-01

    Reduction of viable airborne Staphylococcus epidermidis and Aspergillus niger spore concentrations using two types of photocatalytic fluorescent lamps under controlled environmental conditions (25 vs. 35°C and 55 vs. 75% relative humidity) were investigated. Visible white-light and UVA black light were in-house spray-coated with TiO(2) and then compared with a commercially coated visible white-light for microbial concentration reduction. The white-light photocatalytic lamps reduced the concentration of culturable S. epidermidis up to 92% independent of temperature or humidity change, while the black light photocatalytic lamps completely inactivated the culturable bacteria at 25°C, 55% relative humidity. Humidity seemed to alleviate UVA damage since better bacteria survival was found. For A. niger spores, rising humidity or temperature could lower their concentration or drop their culturabilities so that a difference between the natural decay and photocatalytic disinfection could not be distinguished. Reductions of total bacteria and total fungi concentrations using these lamps were also examined under uncontrolled environmental conditions in an office and a waste-storage room. It was found that photocatalytic lamps could reduce total culturable bacteria concentration from 9 to 97% and total culturable fungi concentration from 3 to 95% within irradiation time of 30-480 min, respectively. Insignificant difference in concentration reduction among these photocatalytic lamps was pronounced. PMID:21339001

  10. A microfluidics-based on-chip impinger for airborne particle collection.

    PubMed

    Mirzaee, I; Song, M; Charmchi, M; Sun, H

    2016-06-21

    Capturing airborne particles from air into a liquid is a critical process for the development of many sensors and analytical systems. A miniaturized airborne particle sampling device (microimpinger) has been developed in this research. The microimpinger relies on a controlled bubble generation process produced by driving air through microchannel arrays. The particles confined in the microscale bubbles are captured in the sampling liquid while the bubbles form, are released and travel in a millimetre-scale sealed liquid reservoir. The microchannel arrays in the impinger are fabricated using a soft-lithography method with polydimethylsiloxane (PDMS) as the structural material. To prevent air leakage at the connections, a PDMS-only sealing technique is successfully developed. The hydrophobicity of the microchannel surface is found to be critical for generating continuous and stable bubbles in the bubbling process. A Teflon layer is coated on the walls of a microchannel array by vapor deposition which effectively increases the hydrophobicity of the PDMS. The collection efficiency of the microimpinger is measured by counting different sizes of fluorescent polystyrene latex particles on polycarbonate membrane filters. Collection efficiencies above 90% are achieved. Furthermore, the particle capturing mechanisms during the injection, formation and rise of a single microbubble are investigated by a computational fluid dynamics (CFD) model. The Navier-Stokes equations are solved along with the use of the volume-of-fluid (VOF) method to capture the bubble deformations and the particles are tracked using a Lagrangian equation of motion. The model is also employed to study the effect of bubble size on the collection efficiency of the microimpinger. PMID:27185303

  11. Diurnal variation in airborne pollen concentrations of the selected taxa in Zagreb, Croatia.

    PubMed

    Toth, Ivan; Peternel, Renata; Srnec, Lidija; Vojniković, Bozo

    2011-09-01

    The number of individuals allergic to plant pollen has recently been on a constant increase. The knowledge of diurnal distribution and abundance of allergenic pollen types, their patterns and response to source position and weather is useful to correlate hay fever symptoms with the presence of allergenic pollen in the atmosphere. The aim of this study was to determine diurnal distribution of total airborne pollen, pollen of particular allergenic taxa, possible variation in diurnal pollen distribution at measuring sites placed at different heights, and effect of some meteorological parameters on airborne pollen concentrations. A 7-day Hirst-type volumetric pollen trap was used for pollen sampling. Qualitative and quantitative pollen analysis was performed under a light microscope (magnification x400). Total pollen of all plant taxa (Ambrosia sp., Betula sp., Cupressaceae, Urticaceae, Poaceae, Quercus sp., Fraxinus sp., Alnus sp., Corylus sp., Populus sp., Pinus sp., Picea sp.) observed showed a regular diurnal distribution at both sampling sites in both study years, with a rise in the pollen concentration recorded after 4.00 a.m. and 6.00 a.m., respectively. The peak pollen concentration occurred between 12.00 a.m. and 4.00 p.m., and the lowest diurnal pollen concentrations were recorded overnight. About 50% of the 24-h pollen concentration were released to the atmosphere between 10.00 a.m. and 4.00 p.m. The timing and size of diurnal peaks were closely related to high temperature, low humidity and south-west maximum wind direction. PMID:22220402

  12. Characterisation of airborne particles collected within and proximal to an opencast coalmine: South Wales, U.K.

    PubMed

    Jones, Tim; Blackmore, Pete; Leach, Matt; Bérubé, Kelly; Sexton, Keith; Richards, Roy

    2002-05-01

    Airborne particulate matter has been collected from within, and proximal to, an opencast coal mine in south Wales. This work forms the first part of a three year project to collect and characterise, then determine the possible toxicology of airborne particles in the south Wales region. High-resolution Field Emission SEM has shown that the coal mine dusts consist largely of an assemblage of mineral grains and vehicle exhaust particles. SEM-EDX has shown that the mineralogical make-up of the PM10 is complex, heterogeneous, and constantly changing. These findings are supported by analytical TEM-EPXMA. However, patterns can be determined relating the mineralogical composition of the airborne particles to collection locations and mining activities within the opencast. At our study opencast, Park Slip West, quartz, which has known health effects, never exceeded 30% of the total collection mass, and average levels were much less. Vehicle exhaust emissions was the largest source in terms of particle numbers. The mass of airborne particulate matter within the pit averaged approximately twice that of outside the pit: importantly however, this higher mass was due to relatively large, and non-respirable, mineral grains. This study demonstrates that the physicochemical and mineralogical characterisation of airborne particles from mining and quarrying is essential to quantify the respirable fraction, and to identify potentially hazardous components within the PM10. PMID:12004982

  13. Adaptation of an Ambient Ion Monitor for Detection of Amines in Airborne Particles

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Agricultural facilities are the source of particles and gases that can exhibit an influence on air quality. Particle mass concentration influences from agricultural sources can include both primary emissions and secondary particle formation through emission of gaseous precursors. An ambient ion moni...

  14. High concentrations of biological aerosol particles and ice nuclei during and after rain

    NASA Astrophysics Data System (ADS)

    Huffman, J. Alex; Pöhlker, Christopher; Prenni, Anthony; DeMott, Paul; Mason, Ryan; Robinson, Niall; Fröhlich-Nowoisky, Janine; Tobo, Yutaka; Després, Viviane; Garcia, Elvin; Gochis, David; Sinha, Bärbel; Day, Douglas; Andreae, Meinrat; Jimenez, Jose; Gallagher, Martin; Kreidenweis, Sonia; Bertram, Allan; Pöschl, Ulrich

    2013-04-01

    Bioaerosols are relevant for public health and may play an important role in the climate system, but their atmospheric abundance, properties and sources are not well understood. Here we show that the concentration of airborne biological particles in a forest ecosystem increases dramatically during rain and that bioparticles are closely correlated with atmospheric ice nuclei (IN). The greatest increase of bioparticles and IN occurred in the size range of 2-6 µm, which is characteristic for bacterial aggregates and fungal spores. By DNA analysis we found high diversities of airborne bacteria and fungi, including human and plant pathogens (mildew, smut and rust fungi, molds, Enterobacteraceae, Pseudomonadaceae). In addition to known bacterial and fungal IN (Pseudomonas sp., Fusarium sporotrichioides), we discovered two species of IN-active fungi that were not previously known as biological ice nucleators (Isaria farinosa and Acremonium implicatum). Our findings suggest that atmospheric bioaerosols, IN and rainfall are more tightly coupled than previously assumed.

  15. High concentrations of biological aerosol particles and ice nuclei during and after rain

    NASA Astrophysics Data System (ADS)

    Huffman, J. A.; Pöhlker, C.; Prenni, A. J.; DeMott, P. J.; Mason, R. H.; Robinson, N. H.; Fröhlich-Nowoisky, J.; Tobo, Y.; Després, V. R.; Garcia, E.; Gochis, D. J.; Harris, E.; Müller-Germann, I.; Ruzene, C.; Schmer, B.; Sinha, B.; Day, D. A.; Andreae, M. O.; Jimenez, J. L.; Gallagher, M.; Kreidenweis, S. M.; Bertram, A. K.; Pöschl, U.

    2013-01-01

    Bioaerosols are relevant for public health and may play an important role in the climate system, but their atmospheric abundance, properties and sources are not well understood. Here we show that the concentration of airborne biological particles in a forest ecosystem increases dramatically during rain and that bioparticles are closely correlated with atmospheric ice nuclei (IN). The greatest increase of bioparticles and IN occurred in the size range of 2-6 μm, which is characteristic for bacterial aggregates and fungal spores. By DNA analysis we found high diversities of airborne bacteria and fungi, including human and plant pathogens (mildew, smut and rust fungi, molds, Enterobacteraceae, Pseudomonadaceae). In addition to known bacterial and fungal IN (Pseudomonas sp., Fusarium sporotrichioides), we discovered two species of IN-active fungi that were not previously known as biological ice nucleators (Isaria farinosa and Acremonium implicatum). Our findings suggest that atmospheric bioaerosols, IN and rainfall are more tightly coupled than previously assumed.

  16. Uranium oxide and other airborne particles deposited on cypress leaves close to a nuclear facility.

    PubMed

    Gieré, Reto; Kaltenmeier, Ramona; Pourcelot, Laurent

    2012-04-01

    Enhanced activity of actinides and some decay products has been reported for the leaves of cypress trees (Chamaecyparis nootkatensis) at the edge of the Malvési uranium-processing facility, southwestern France. The enhanced activity is due to the release of actinides via the smokestacks and from artificial ponds inside the facility. This study was conducted to characterize airborne particulate matter deposited on the leaf surfaces and to investigate whether or not radioactive particles may be identified. Air-dried leaf samples were examined by scanning electron microscopy, in combination with energy-dispersive X-ray spectrometry. The samples were scanned systematically in both secondary and backscattered electron modes. Particles ranging in size from <200 nm to ~40 μm were found on most portions of the adaxial leaf surface, but they are especially abundant at the boundary between facial and lateral leaves. The majority of the analyzed particles could be attributed to five principal classes: carbonates, silicates, sulfates, oxides/hydroxides, and halides. In addition, other types of particles were found, including Fe alloys; scheelite-group phases; phosphates; sulfides; and fly ash spheres. Similar particles were also observed on the surface of a wheat sample used for comparison. Of special interest are U-rich particles, which were observed on the cypress leaves only and which were identified as U oxides, except for one particle, which was a U-oxide-fluoride. These U-rich particles were released into the atmosphere by the nuclear facility prior to their deposition on the leaf surfaces. As most of the U-rich particles are <2.5 μm across, they are respirable. Once inhaled, particles containing alpha-emitting isotopes represent a potentially long-term source of ionizing radiation inside the lungs and thus, pose a threat to the health of people living nearby. PMID:22422019

  17. Effect of indoor-generated airborne particles on radon progeny dynamics.

    PubMed

    Trassierra, C Vargas; Stabile, L; Cardellini, F; Morawska, L; Buonanno, G

    2016-08-15

    In order to investigate the interaction between radon progeny and particles, an experimental campaign was carried out in a radon chamber at the Italian National Institute of Ionizing Radiation Metrology, quantifying the amount of attached and unattached radon daughters present in air, as well as the equilibrium factor in the presence of particles generated through indoor sources. A fixed radon concentration was maintained, while particles were generated using incense sticks, mosquito coils and gas combustion. Aerosols were characterized in terms of particle concentrations and size distributions. Simultaneously, radon concentration and attached/unattached potential alpha energy concentration in the air were continuously monitored by two different devices, based on alpha spectroscopy techniques. The presence of particles was found to affect the attached fraction of radon decay products, in such a way that the particles acted as a sink for radionuclides. In terms of sources which emit large particles (e.g. incense, mosquito coils), which greatly increase particle surface area concentrations, the Equilibrium Factor was found to double with respect to the background level before particle generation sessions. On the contrary, the radon decay product dynamics were not influenced by gas combustion processes, mainly due to the small surface area of the particles emitted. PMID:27131455

  18. Discriminating bacterial spores from inert airborne particles by classification of optical scattering patterns

    NASA Astrophysics Data System (ADS)

    Crosta, Giovanni F.; Pan, Yongle; Videen, Gorden

    2014-05-01

    Scattering patterns are made available by the TAOS (Two-dimensional Angle-resolved Optical Scattering) method, which consists of detecting micrometer-sized single airborne aerosol particles and collecting the intensity of the light they scatter from a pulsed, monochromatic laser beam. TAOS patterns have been classified by a learning machine, the training stage of which depends on many control parameters. Patterns due to single bacterial spores (Bq class) have to be discriminated from those produced by outdoor aerosol particles (Kq set) and diesel soot aggregates (sq set), where both Kq and sq are assumed not to contain patterns of bacterial origin. This work describes two directions along which classification continues to develop: the enlargement of the control parameter set and the simultaneous processing of two areas (sectors) selected from the TAOS pattern. The latter algorithm is meant to make the classifier sensitive to simmetry exhibited by some patterns. The available classification scheme is summarized, as well as the rule by which discrimination is rated off-line. Discrimination based on one pattern sector alone scores fewer than 15% false negatives (misclassified Bq patterns) and false positives from Kq and sq. Discrimination based on the symmetry of two pattern sectors fails to recognize 30% of the Bq (bacterial) patterns, whereas < 5% Kq (environmental) patterns are assigned to the Bq class; false positives from sq (diesel) patterns drop to zero. The issue of false positives is briefly discussed in relation to the fraction of airborne bacteria found in aerosols.

  19. Design and Laboratory Evaluation of a Sequential Spot Sampler for Time-Resolved Measurement of Airborne Particle Composition

    PubMed Central

    Eiguren Fernandez, Arantzazu; Lewis, Gregory S.; Hering, Susanne V.

    2014-01-01

    A new sampling approach has been developed to enable affordable, time-resolved monitoring of particulate chemical compositions, and more generally to provide concentrated samples of airborne particles. Using a newly developed, moderated water-based condensational growth technology, individual particle samples are deposited in a 1-mm diameter dry “spot”. The moderated condensation technology enables this collection with minimal temperature rise, providing robust collection for volatile constituents. Measured collection efficiencies are above 95% for particles in the size range from 0.010 μm to 2.5 μm. A set of 20 or more time-resolved samples, plus blanks, may be collected onto a multiwell collection plate. For chemical analysis the plate is returned to the laboratory, and placed directly into a modified autosampler, without extraction or preparation. The autosampler handles the addition of eluent, extraction, and sample injection without user manipulation. This paper presents the design and laboratory evaluation of a 1.5 L/min sampling rate version of this system. PMID:25045199

  20. Laboratory testing of airborne brake wear particle emissions using a dynamometer system under urban city driving cycles

    NASA Astrophysics Data System (ADS)

    Hagino, Hiroyuki; Oyama, Motoaki; Sasaki, Sousuke

    2016-04-01

    To measure driving-distance-based mass emission factors for airborne brake wear particulate matter (PM; i.e., brake wear particles) related to the non-asbestos organic friction of brake assembly materials (pads and lining), and to characterize the components of brake wear particles, a brake wear dynamometer with a constant-volume sampling system was developed. Only a limited number of studies have investigated brake emissions under urban city driving cycles that correspond to the tailpipe emission test (i.e., JC08 or JE05 mode of Japanese tailpipe emission test cycles). The tests were performed using two passenger cars and one middle-class truck. The observed airborne brake wear particle emissions ranged from 0.04 to 1.4 mg/km/vehicle for PM10 (particles up to 10 μm (in size), and from 0.04 to 1.2 mg/km/vehicle for PM2.5. The proportion of brake wear debris emitted as airborne brake wear particles was 2-21% of the mass of wear. Oxygenated carbonaceous components were included in the airborne PM but not in the original friction material, which indicates that changes in carbon composition occurred during the abrasion process. Furthermore, this study identified the key tracers of brake wear particles (e.g., Fe, Cu, Ba, and Sb) at emission levels comparable to traffic-related atmospheric environments.

  1. Radon in indoor concentrations and indoor concentrations of metal dust particles in museums and other public buildings.

    PubMed

    Carneiro, G L; Braz, D; de Jesus, E F; Santos, S M; Cardoso, K; Hecht, A A; Dias da Cunha, Moore K

    2013-06-01

    The aim of this study was to evaluate the public and occupational exposure to radon and metal-bearing particles in museums and public buildings located in the city of Rio de Janeiro, Brazil. For this study, four buildings were selected: two historic buildings, which currently house an art gallery and an art museum; and two modern buildings, a chapel and a club. Integrated radon concentration measurements were performed using passive radon detectors with solid state nuclear track detector-type Lexan used as nuclear track detector. Air samplers with a cyclone were used to collect the airborne particle samples that were analyzed by the particle-induced X-ray emission technique. The average unattached-radon concentrations in indoor air in the buildings were above 40 Bq/m(3), with the exception of Building D as measured in 2009. The average radon concentrations in indoor air in the four buildings in 2009 were below the recommended reference level by World Health Organization (100 Bq/m(3)); however, in 2011, the average concentrations of radon in Buildings A and C were above this level, though lower than 300 Bq/m(3). The average concentrations of unattached radon were lower than 148 Bq/m(3) (4pCi/L), the USEPA level recommended to take action to reduce the concentrations of radon in indoor air. The unattached-radon average concentrations were also lower than the value recommended by the European Union for new houses. As the unattached-radon concentrations were below the international level recommended to take action to reduce the radon concentration in air, it was concluded that during the period of sampling, there was low risk to human health due to the inhalation of unattached radon in these four buildings. PMID:23124728

  2. A benchmark for numerical scheme validation of airborne particle exposure in street canyons.

    PubMed

    Marini, S; Buonanno, G; Stabile, L; Avino, P

    2015-02-01

    Measurements of particle concentrations and distributions in terms of number, surface area, and mass were performed simultaneously at eight sampling points within a symmetric street canyon of an Italian city. The aim was to obtain a useful benchmark for validation of wind tunnel experiments and numerical schemes: to this purpose, the influence of wind directions and speeds was considered. Particle number concentrations (PNCs) were higher on the leeward side than the windward side of the street canyon due to the wind vortex effect. Different vertical PNC profiles were observed between the two canyon sides depending on the wind direction and speed at roof level. A decrease in particle concentrations was observed with increasing rooftop wind speed, except for the coarse fraction indicating a possible particle resuspension due to the traffic and wind motion. This study confirms that particle concentration fields in urban street canyons are strongly influenced by traffic emissions and meteorological parameters, especially wind direction and speed. PMID:25167823

  3. In situ real-time measurement of physical characteristics of airborne bacterial particles

    NASA Astrophysics Data System (ADS)

    Jung, Jae Hee; Lee, Jung Eun

    2013-12-01

    Bioaerosols, including aerosolized bacteria, viruses, and fungi, are associated with public health and environmental problems. One promising control method to reduce the harmful effects of bioaerosols is thermal inactivation via a continuous-flow high-temperature short-time (HTST) system. However, variations in bioaerosol physical characteristics - for example, the particle size and shape - during the continuous-flow inactivation process can change the transport properties in the air, which can affect particle deposition in the human respiratory system or the filtration efficiency of ventilation systems. Real-time particle monitoring techniques are a desirable alternative to the time-consuming process of microscopic analysis that is conventionally used in sampling and particle characterization. Here, we report in situ real-time optical scattering measurements of the physical characteristics of airborne bacteria particles following an HTST process in a continuous-flow system. Our results demonstrate that the aerodynamic diameter of bacterial aerosols decreases when exposed to a high-temperature environment, and that the shape of the bacterial cells is significantly altered. These variations in physical characteristics using optical scattering measurements were found to be in agreement with the results of scanning electron microscopy analysis.

  4. The control by ventilation of airborne bacterial transfer between hospital patients, and its assessment by means of a particle tracer

    PubMed Central

    Foord, N.; Lidwell, O. M.

    1972-01-01

    A simple and convenient particle tracer for studies of the effectiveness of isolation units and other places in limiting the airborne transfer of bacteria is described. Particles of potassium iodide 7-8 μm. diameter are generated by spraying from solution and collected on membrane filters. The particles can be identified by development with 0·1% acid palladium chloride solution, when dark brown spots approximately 100 μm. in diameter are produced. ImagesPlate 1 PMID:4503869

  5. Sedimentation of multisized particles in concentrated suspensions

    SciTech Connect

    Selim, M.S.; Kothari, A.C.; Turian, R.M.

    1983-11-01

    A model is developed for predicting the sedimentation velocity in suspensions of multisized nonflocculating solids, in which the retarding effect of the smaller particles on the setting velocities of the larger ones is taken into account. Tests of the model, and comparisons with other models, demonstrate that it provides improved prediction of data on suspensions comprising both discrete particle size mixtures and continuous size distributions, and that it is applicable to continuous countercurrent solid-liquid operations.

  6. Size distribution and number concentration of particles at the stack of a municipal waste incinerator.

    PubMed

    Buonanno, G; Ficco, G; Stabile, L

    2009-02-01

    A large number of particles and gaseous products are generated by waste combustion processes. Of particular importance are the ultrafine particles (less than 0.1 microm in aerodynamic diameter) that are emitted in large quantities from all the combustion sources. Recent findings of toxicological and epidemiological studies indicate that fine and ultrafine particles could represent health and environmental risks. Quantifying particulate emissions from combustion sources is important: (i) to examine the source status in compliance with regulations; (ii) to create inventories of such emissions at local, regional and national levels, for developing appropriate management and control strategies in relation to air quality; (iii) to predict ambient air quality in the areas involved at the source and (iv) to perform source apportionment and exposure assessment for the human populations and/or ecological systems involved. In order to control and mitigate the particles in the view of health and environmental risk reduction, a good understanding of the relative and absolute contribution from the emission sources to the airborne concentrations is necessary. For these purposes, the concentration and size distribution of particles in terms of mass and number in a waste gas of a municipal waste incineration plant were measured in the stack gas. The mass concentrations obtained are well below the imposed daily threshold value for both incineration lines and the mass size distribution is on average very stable. The total number concentrations are between 1 x 10(5) and 2 x 10(5)particles/cm(3) and are on average relatively stable from one test to another. The measured values and the comparison with other point sources show a very low total number concentration of particles at the stack gas, revealing the importance of the flue gas treatment also for ultrafine particles. Also in respect to linear sources (high and light duty vehicles), the comparison shows a negligible emission in

  7. Relationship of airborne trimellitic anhydride concentrations to trimellitic anhydride--induced symptoms and immune responses

    SciTech Connect

    Bernstein, D.I.; Roach, D.E.; McGrath, K.G.; Larsen, R.S.; Zeiss, C.R.; Patterson, R.

    1983-12-01

    Eighteen workers exposed to trimellitic anhydride (TMA) powder were evaluated in 1979. Twelve of these workers were available for longitudinal study until 1982. Annual clinical evaluations and serum radioimmunoassays for total antibody binding and specific IgE binding to /sup 125/I-TM-HSA were performed. In 1979, five workers had antibody against TM-HSA. Of these, three workers were diagnosed with the late respiratory systemic syndrome (LRSS) and one worker with TMA-induced allergic rhinitis. The LRSS workers had significantly elevated total antibody binding of /sup 125/I-TM-HSA and the worker with rhinitis had significantly elevated specific IgE binding of /sup 125/I-TM-HSA per milliliter of serum. Although TMA handling was intermittent throughout the year, average airborne dust concentrations from 1974 to 1978 at job stations of the two heaviest TMA-exposed occupations, operator and assistant operator, were 2.1 and 0.82 mg/m3, respectively. After local exhaust ventilation had been improved, average airborne dust concentrations of TMA at the two latter job stations fell to levels of 0.03 and 0.01 mg/m3, respectively, in 1982. The decrease in TMA exposure coincided with a gradual fall in total antibody binding of /sup 125/I-TM-HSA per milliliter in 1982 and symptomatic improvement in the three individuals with the LRSS. The continuous low-level exposure of the worker with TMA rhinitis was sufficient to elicit a rise in specific IgE against TM-HSA from 1.1 ng of 125I-TM-HSA bound per milliliter in 1979 to 2.12 in 1982.

  8. Total element concentration and chemical fractionation in airborne particulate matter from Santiago, Chile

    NASA Astrophysics Data System (ADS)

    Richter, Pablo; Griño, Paulina; Ahumada, Inés; Giordano, Ady

    Total element determination and chemical fractionation were carried out in airborne particulate matter (PM 10) from the Cerrillos monitoring station in Santiago, Chile, sampled in July (winter), 1997-2003. Element concentration in the period under study (1997-2003) was statistically analyzed through cluster analysis in order to identify groups of elements having similar behavior along time. Elements such as Cd, Cu, Pb, Ni, As and Mg show a clear decrease in concentration with time. On the contrary, chromium increases its concentration almost linearly during the period. In order to estimate whether the presence of a certain element in PM 10 matrix is mainly due to anthropogenic or natural processes, the enrichment factor of each element was determined. According to their behavior in the sequential extraction procedure, the elements were grouped by multivariate analysis in three clusters: (a) those mobile elements (Pb, Cd, Zn, Mn, Cu and As) which are weakly bound to the matrix (fractions 1 and 2) (b) those elements (V, Ti, and Cr) mainly bound to carbonates and oxides (fraction 3) and (c) the most immobile elements (Ni, Mo, Ca, Mg, Ba and Al), mainly bound to silicates and organic matter (fraction 4). A source of great concern is the fact that elements of such high toxicity as Pb, Cd and As are highly concentrated in both mobile fractions, indicating that these elements have a direct impact on the environment and on the health of the exposed population.

  9. Chemical and isotopic properties and origin of coarse airborne particles collected by passive samplers in industrial, urban, and rural environments

    NASA Astrophysics Data System (ADS)

    Guéguen, Florence; Stille, Peter; Dietze, Volke; Gieré, Reto

    2012-12-01

    Passive air samplers have been installed in industrial, urban, rural and remote forested environments in order to collect coarse airborne particles for subsequent chemical characterization. To identify principal polluting sources, isotopic tracers, such as Sr, Nd and Pb isotopic ratios, have been used. The mass deposition rates (MDRs) of trace metals, determined for each of the studied environments, clearly indicate that industrial and traffic sites are especially affected by air pollution. Elements such as V, Pb, Fe, Cr, Co, Mo, Cd, Ni, As, Sb and Zn are notably enriched in samples from industrial zones, whereas V, Mn, Ba, Sr, Al, U, Th, rare earth elements (REE), Zr, Y, Cs, Rb, Sb, Sn and Cu are principal components of the airborne particles collected close to areas influenced by heavy traffic. The chemical/isotopic baseline composition derived from the airborne particles is the result of mixing of particles from different industrial sources, traffic and fertilizers. The monthly analysis of trace-metal MDRs of the collected airborne particle samples from different stations around the industrial zone allows for the detection of distinct atmospheric dust-deposition events during the year, characterized by high MDRs. "Natural" dusts from regional soil re-suspension, including from more distant regions like the Sahara desert, might overprint the regional atmospheric baseline composition, as suggested by trace metal trajectories in ternary diagrams and by Sr, Nd and Pb isotope data.

  10. Atmospheric Solids Analysis Probe Mass Spectrometry: A New Approach for Airborne Particle Analysis

    SciTech Connect

    Bruns, Emily A.; Perraud, Veronique M.; Greaves, John; Finlayson-Pitts, Barbara J.

    2010-07-15

    Secondary organic aerosols (SOA) formed in the atmosphere from the condensation of semivolatile oxidation products are a significant component of airborne particles which have deleterious effects on health, visibility, and climate. In this study, atmospheric solids analysis probe mass spectrometry (ASAP-MS) is applied for the first time to the identification of organics in particles from laboratory systems as well as from ambient air. SOA were generated in the laboratory from the ozonolysis of r-pinene and isoprene, as well as from NO3 oxidation of r-pinene, and ambient air was sampled at forested and suburban sites. Particles were collected by impaction on ZnSe disks, analyzed by Fourier transform-infrared spectroscopy (FT-IR) and then transferred to an ASAP-MS probe for further analysis. ASAP-MS data for the laboratory-generated samples show peaks from wellknown products of these reactions, and higher molecular weight oligomers are present in both laboratory and ambient samples. Oligomeric products are shown to be present in the NO3 reaction products for the first time. A major advantage of this technique is that minimal sample preparation is required, and complementary information from nondestructive techniques such as FT-IR can be obtained on the same samples. In addition, a dedicated instrument is not required for particle analysis. This work establishes that ASAP-MS will be useful for identification of organic components of SOA in a variety of field and laboratory studies.

  11. Atmospheric solids analysis probe mass spectrometry: a new approach for airborne particle analysis.

    PubMed

    Bruns, Emily A; Perraud, Véronique; Greaves, John; Finlayson-Pitts, Barbara J

    2010-07-15

    Secondary organic aerosols (SOA) formed in the atmosphere from the condensation of semivolatile oxidation products are a significant component of airborne particles which have deleterious effects on health, visibility, and climate. In this study, atmospheric solids analysis probe mass spectrometry (ASAP-MS) is applied for the first time to the identification of organics in particles from laboratory systems as well as from ambient air. SOA were generated in the laboratory from the ozonolysis of alpha-pinene and isoprene, as well as from NO(3) oxidation of alpha-pinene, and ambient air was sampled at forested and suburban sites. Particles were collected by impaction on ZnSe disks, analyzed by Fourier transform-infrared spectroscopy (FT-IR) and then transferred to an ASAP-MS probe for further analysis. ASAP-MS data for the laboratory-generated samples show peaks from well-known products of these reactions, and higher molecular weight oligomers are present in both laboratory and ambient samples. Oligomeric products are shown to be present in the NO(3) reaction products for the first time. A major advantage of this technique is that minimal sample preparation is required, and complementary information from nondestructive techniques such as FT-IR can be obtained on the same samples. In addition, a dedicated instrument is not required for particle analysis. This work establishes that ASAP-MS will be useful for identification of organic components of SOA in a variety of field and laboratory studies. PMID:20568716

  12. Influence of urban climate upon distribution of airborne Deuteromycete spore concentrations in Mexico City

    NASA Astrophysics Data System (ADS)

    Calderón, C.; Lacey, J.; McCartney, A.; Rosas, I.

    The effect of an urban climate upon the spatial and temporal distribution of Deuteromycete spores was studied during 1991 using Burkard volumetric spore traps in two areas of Mexico City with different degrees of urbanization. Deuteromycete conidia formed the largest component of the total airborne fungal spore load in the atmosphere of Mexico City, contributing 52% of the spores trapped in an urban-residential area (southern area) and 65% of those in an urban-commercial area (central area). Among the most common spore types, Cladosporium and Alternaria showed a marked seasonal periodicity with significant differences in concentration (P<0.05) between the dry and wet seasons. Maximum conidial concentrations were found during the end of the wet season and the beginning of the cool, dry season (October-December). Daily mean concentrations of the predominant airborne spore types did not differ significantly between the southern and central areas. Daily mean spore concentrations were significantly correlated (P<0.05) in southern and central areas with maximum temperature (south, r = -0.35 central, r = -0.40) and relative humidity (south, r = 0.43; central, r = 0.29) from the previous day. Moreover, multiple regression analysis of spore concentrations with several meteorological factors showed significant interactions between fungal spores, relative humidity and maximum temperature in both areas. The diurnal periodicity of Cladosporium conidia characteristically showed two or three peaks in concentration during the day at 0200-0400, 1400 and 2000-2200 hours, while that of Alternaria showed only one peak (1200 to 2000 hours) in both areas. Maximum concentrations of these spores generally occurred 2-4 h earlier in the southern than in the central area. The lag in reaching maximum concentrations in the central area probably resulted from differences in the local conditions between the study areas, and from spores transported aerially into the city from distant sources. The

  13. Induction of sister chromatid exchanges and bacterial revertants by organic extracts of airborne particles. [Humans

    SciTech Connect

    Lockard, J.M.; Viau, C.J.; Lee-Stephens, C.; Caldwell, J.C.; Wojciechowski, J.P.; Enoch, H.G.; Sabharwal, P.S.

    1981-01-01

    The genotoxicities of organic extracts of airborne particles have been studied extensively in the Salmonella/mammalian microsome (Ames) test, but in few other bioassays. In these studies, we tested benzene-acetone extracts of particulate pollutants collected in Lexington, Kentucky, for capacity to induce increases in sister chromatid exchanges (SCE) in human lumphocytes and V79 cells, as well as in the Ames assay. Extracts induced linear dose-related increases in SCE in human lumphocytes and in bacterial revertants.However, variable responses were observed in SCE assays in V79 cells with and without activation by rat liver S9 or feeder layers of irradiated Syrian hamster fetal cells. We conclude that the SCE assay in human lumphocytes may be a useful indicator of the potential risks to humans of airborne particulate pollutants, as it utilizes human cells recently taken from the host, is rapid and economical, and requires small quantities of test materials. However, thorough studies of the quantitative relationships between SCE induction and mutagenicity in human cells are needed.

  14. Particle number size distribution in the eastern Mediterranean: Formation and growth rates of ultrafine airborne atmospheric particles

    NASA Astrophysics Data System (ADS)

    Kopanakis, I.; Chatoutsidou, S. E.; Torseth, K.; Glytsos, T.; Lazaridis, M.

    2013-10-01

    Particle number concentration was measured between June 2009 and June 2010 at Akrotiri research station in a rural/suburban region of western Crete (Greece). Overall, the available data covered 157 days during the aforementioned period of measurements. The objectives were to study the number size distribution characteristics of ambient aerosols and furthermore to identify new particle formation events and to evaluate particle formation rates and growth rates of the newborn particles. Aerosol particles with mobility diameters between 10 and 1100 nm were measured using a Scanning Mobility Particle Sizer (SMPS) system. Measurements were performed at ambient relative humidities. The median total particle number concentration was 525 #/cm3 whereas the number concentration ranged between 130 #/cm3 and 9597 #/cm3. The average percentage of particles with diameters between 10 nm and 100 nm (N10-100) to total particles was 53% during summer and spring, but reached 80% during winter. Maximum average contribution of nano-particles (10 nm < Dp < 50 nm) to total particles was recorded also in winter and was attributed partly to the effect of local heating. Furthermore, back trajectories (HYSPLIT model) showed that different air mass origins are linked to different levels of particle number concentrations, with higher values associated with air masses passing from polluted areas before reaching the Akrotiri station. Modal analysis of the measured size distribution data revealed a strong nucleation mode during winter (15-25 nm), which can be correlated with emissions from local sources (domestic heating). The nucleation mode was observed also during the spring campaigns and was partly linked to new particle formation events. On the contrary, an accumulation mode (80-120 nm) prevailed in the measurements during summer campaigns, when the station area was influenced by polluted air masses arriving mainly from Eastern Europe. In total, 13 new particle formation events were recorded

  15. Analysis of particle-borne odorants emitted from concentrated animal feeding operations.

    PubMed

    Yang, Xufei; Lorjaroenphon, Yaowapa; Cadwallader, Keith R; Wang, Xinlei; Zhang, Yuanhui; Lee, Jongmin

    2014-08-15

    Airborne particles are known to serve as a carrier of odors emanating from concentrated animal feeding operations (CAFOs). However, limited quantitative data about particle-borne odorants preclude an accurate assessment of the role of particles in odor transport. This study collected total suspended particulates (TSP) and PM10 (particles with aerodynamic diameter smaller than 10 μm) at the air exhaust of eight types of CAFOs (swine: farrowing, gestation, weaning, and finishing; poultry: manure-belt layer hen, tom turkey, chicken broiler, and cage-free layer hen; in total 20 animal buildings) in multiple seasons, and examined the variability in particle odorant composition with animal operation type, season, and particle size. Fifty-seven non-sulfur-containing odorants were identified and quantitated, including carbonyls, alcohols, acids, phenols, and nitrogen-containing compounds. They in total accounted for 2.19±1.52% TSP and 4.97±3.25% PM10 mass. Acetic acid and ethanol were most abundant but less odor-contributing than phenylacetic acid, indole, dodecanoic acid, and (E,E)-2,4-decadienal, as determined by odor activity value. Particle odorant composition varied significantly with animal operation type, season, and particle size. The TSP and PM10 samples from swine gestation buildings, for example, showed distinctly different odorant compositions than those from tom turkey buildings. The summer TSP and PM10 samples contained in general lower concentrations of short-chain fatty acids but higher concentrations of long-chain fatty acids, aldehydes, and short-chain alcohols than the winter samples. Compared to TSP, PM10 samples from different types of CAFOs shared a more similar odorant composition, contained higher odorant concentrations per mass of particles, and accounted for on average 53.2% of the odor strength of their corresponding TSP samples. PMID:24863138

  16. Factors influencing the airborne capture of respirable charged particles by surfactants in water sprays.

    PubMed

    Tessum, Mei W; Raynor, Peter C; Keating-Klika, Lorraine

    2014-01-01

    This research measured the effects of particle diameter, surfactant-containing spray solution, and particle charge on the capture of respirable particles by surfactant-containing water spray droplets. Polystyrene latex particles with diameters of 0.6, 1.0, or 2.1 μm were generated in a wind tunnel. Particles were given either a neutralized, unneutralized, net positive, or net negative charge, and then were captured as they passed through sprays containing anionic, cationic, or nonionic surfactant. The remaining particles were sampled, charge-separated, and counted with the sprays on and off at varying voltage levels to assess collection efficiency. Overall efficiencies were measured for particles with all charge levels, as well as efficiencies for particles with specific charge levels. The overall collection efficiency significantly increased with increasing particle diameter. Collection efficiencies of 21.5% ± 9.0%, 58.8% ± 12.5%, and 86.6% ± 43.5% (Mean ± SD) were observed for particles 0.6, 1.0, and 2.1 μm in diameter, respectively. The combination of surfactant classification and concentration also significantly affected both overall spray collection efficiency and collection efficiency for particles with specific charge levels. Ionic surfactant-containing sprays had the best performance for charged particles with the opposite sign of charge but the worst performance for charged particles with the same sign of charge, while nonionic surfactant-containing spray efficiently removed particles carrying relatively few charges. Particle charge level impacted the spray collection efficiency. Highly charged particles were removed more efficiently than weakly charged particles. PMID:24479508

  17. Electrophoretic mobility of particles in concentrated solutions of electrolytes

    SciTech Connect

    Deinega, Yu.F.; Polyakova, V.M.; Aleksandrova, L.N.

    1986-11-01

    The electrophoretic mobility of particles of phenol-formaldehyde and aniline-formaldehyde resins in zinc sulfate solutions has been investigated. It is shown that as the electrolyte concentration rises, the electrophoretic mobility falls, reaches a minimum, and then increases. A possible mechanism for the formation of an electric double layer on the surface of particles in concentrated solutions of electrolytes is proposed.

  18. EVALUATION OF THREE CLEANING METHODS FOR REMOVING ASBESTOS FROM CARPET: DETERMINATION OF AIRBORNE ASBESTOS CONCENTRATIONS ASSOCIATED WITH EACH METHOD

    EPA Science Inventory

    This study was conducted to compare the effectiveness of three cleaning methods to remove asbestos from contaminated carpet and to determine the airborne asbestos concentrations associated with the use of each method. he carpet on which the methods were tested was naturally conta...

  19. EVALUATION OF THREE CLEANING METHODS FOR REMOVING ASBESTOS FROM CARPET. DETERMINATION OF AIRBORNE ASBESTOS CONCENTRATIONS ASSOCIATED WITH EACH METHOD

    EPA Science Inventory

    This study was conducted to compare the effectiveness of three cleaning methods to remove asbestos from contaminated carpet and to determine the airborne asbestos concentrations associated with the use of each method. The carpet on which the methods were tested was naturally cont...

  20. Ambient Airborne Solids Concentrations Including Volcanic Ash at Hanford, Washington Sampling Sites Subsequent to the Mount St. Helens Eruption

    SciTech Connect

    Sehmel, G.A.

    1982-12-20

    A major eruption of Mount St. Helens occurred on May 18, 1980. Subsequently, airborne solid concentrations were measured as a function of time at two sites within the southern edge of the fallout plume about 211 km east of Mount St. Helens. This ash was a source for investigating area-wide resuspension. Rain had a variable effect on decreasing airborne concentrations from resuspension. From 0.5 to 1.5 cm of rain were required to significantly reduce airborne solid concentrations through July. For a more aged resuspension source in September, a rain of 2.0 cm had a negligible effect. A monthly average threshold-wind speed for resuspension was defined as 3.6 m/s. For monthly-average wind speeds less than the threshold wind speed, monthly-average airborne concentrations tended to decrease with time. A decrease was recorded between September and October. For this 4-month time period, the half-life was on the order of 50 days, corresponding to a weathering rate of 5.1 year/sup -1/.

  1. The future of airborne sulfur-containing particles in the absence of fossil fuel sulfur dioxide emissions

    PubMed Central

    Perraud, Véronique; Horne, Jeremy R.; Martinez, Andrew S.; Kalinowski, Jaroslaw; Meinardi, Simone; Dawson, Matthew L.; Wingen, Lisa M.; Dabdub, Donald; Blake, Donald R.; Gerber, R. Benny; Finlayson-Pitts, Barbara J.

    2015-01-01

    Sulfuric acid (H2SO4), formed from oxidation of sulfur dioxide (SO2) emitted during fossil fuel combustion, is a major precursor of new airborne particles, which have well-documented detrimental effects on health, air quality, and climate. Another precursor is methanesulfonic acid (MSA), produced simultaneously with SO2 during the atmospheric oxidation of organosulfur compounds (OSCs), such as dimethyl sulfide. In the present work, a multidisciplinary approach is used to examine how contributions of H2SO4 and MSA to particle formation will change in a large coastal urban area as anthropogenic fossil fuel emissions of SO2 decline. The 3-dimensional University of California Irvine–California Institute of Technology airshed model is used to compare atmospheric concentrations of gas phase MSA, H2SO4, and SO2 under current emissions of fossil fuel-associated SO2 and a best-case futuristic scenario with zero fossil fuel sulfur emissions. Model additions include results from (i) quantum chemical calculations that clarify the previously uncertain gas phase mechanism of formation of MSA and (ii) a combination of published and experimental estimates of OSC emissions, such as those from marine, agricultural, and urban processes, which include pet waste and human breath. Results show that in the zero anthropogenic SO2 emissions case, particle formation potential from H2SO4 will drop by about two orders of magnitude compared with the current situation. However, particles will continue to be generated from the oxidation of natural and anthropogenic sources of OSCs, with contributions from MSA and H2SO4 of a similar order of magnitude. This could be particularly important in agricultural areas where there are significant sources of OSCs. PMID:26483454

  2. The future of airborne sulfur-containing particles in the absence of fossil fuel sulfur dioxide emissions.

    PubMed

    Perraud, Véronique; Horne, Jeremy R; Martinez, Andrew S; Kalinowski, Jaroslaw; Meinardi, Simone; Dawson, Matthew L; Wingen, Lisa M; Dabdub, Donald; Blake, Donald R; Gerber, R Benny; Finlayson-Pitts, Barbara J

    2015-11-01

    Sulfuric acid (H2SO4), formed from oxidation of sulfur dioxide (SO2) emitted during fossil fuel combustion, is a major precursor of new airborne particles, which have well-documented detrimental effects on health, air quality, and climate. Another precursor is methanesulfonic acid (MSA), produced simultaneously with SO2 during the atmospheric oxidation of organosulfur compounds (OSCs), such as dimethyl sulfide. In the present work, a multidisciplinary approach is used to examine how contributions of H2SO4 and MSA to particle formation will change in a large coastal urban area as anthropogenic fossil fuel emissions of SO2 decline. The 3-dimensional University of California Irvine-California Institute of Technology airshed model is used to compare atmospheric concentrations of gas phase MSA, H2SO4, and SO2 under current emissions of fossil fuel-associated SO2 and a best-case futuristic scenario with zero fossil fuel sulfur emissions. Model additions include results from (i) quantum chemical calculations that clarify the previously uncertain gas phase mechanism of formation of MSA and (ii) a combination of published and experimental estimates of OSC emissions, such as those from marine, agricultural, and urban processes, which include pet waste and human breath. Results show that in the zero anthropogenic SO2 emissions case, particle formation potential from H2SO4 will drop by about two orders of magnitude compared with the current situation. However, particles will continue to be generated from the oxidation of natural and anthropogenic sources of OSCs, with contributions from MSA and H2SO4 of a similar order of magnitude. This could be particularly important in agricultural areas where there are significant sources of OSCs. PMID:26483454

  3. Characterisation of airborne particles and associated organic components produced from incense burning.

    PubMed

    Chuang, Hsiao-Chi; Jones, Tim; Chen, Yang; Bell, Jennifer; Wenger, John; BéruBé, Kelly

    2011-12-01

    Airborne particles generated from the burning of incense have been characterized in order to gain an insight into the possible implications for human respiratory health. Physical characterization performed using field-emission scanning electron microscopy showed incense particulate smoke mainly consisted of soot particles with fine and ultrafine fractions in various aggregated forms. A range of organic compounds present in incense smoke have been identified using derivatisation reactions coupled with gas chromatography-mass spectrometry analysis. A total of 19 polar organic compounds were positively identified in the samples, including the biomass burning markers levoglucosan, mannosan and galactosan, as well as a number of aromatic acids and phenols. Formaldehyde was among 12 carbonyl compounds detected and predominantly associated with the gas phase, whereas six different quinones were also identified in the incense particulate smoke. The nano-structured incense soot particles intermixed with organics (e.g. formaldehyde and quinones) could increase the oxidative capacity. When considering the worldwide prevalence of incense burning and resulting high respiratory exposures, the oxygenated organics identified in this study have significant human health implications, especially for susceptible populations. PMID:21769554

  4. Alternate particle removal technologies for the Airborne Activity Confinement System at the Savannah River Site

    SciTech Connect

    Brockmann, J.E.; Adkins, C.L.J.; Gelbard, F. )

    1991-09-01

    This report presents a review of the filtration technologies available for the removal of particulate material from a gas stream. It was undertaken to identify alternate filtration technologies that may be employed in the Airborne Activity Confinement System (AACS) at the Savannah River Plant. This report is organized into six sections: (1) a discussion of the aerosol source term and its definition, (2) a short discussion of particle and gaseous contaminant removal mechanisms, (3) a brief overview of particle removal technologies, (4) a discussion of the existing AACS and its potential shortcomings, (5) an enumeration of issues to be addressed in upgrading the AACS, and, (6) a detailed discussion of the identified technologies. The purpose of this report is to identity available options to the existing particle removal system. This system is in continuous operation during routine operation of the reactor. As will be seen, there are a number of options and the selection of any technology or combination of technologies will depend on the design aerosol source term (yet to be appropriately defined) as well as the flow requirements and configuration. This report does not select a specific technology. It focuses on particulate removal and qualitatively on the removal of radio-iodine and mist elimination. Candidate technologies have been selected from industrial and nuclear gas cleaning applications.

  5. Wind barriers suppress fugitive dust and soil-derived airborne particles in arid regions

    SciTech Connect

    Grantz, D.A.; Vaughn, D.L.; Farber, R.J.; Kim, B.; Ashbaugh, L.; Van Curen, T.; Campbell, R.

    1998-07-01

    Areas of abandoned agricultural land in the Antelope Valley, western Mojave (high) desert of California have proven in the previous studies to be recalcitrant to conventional tillage and revegetation strategies designed to suppress wind erosion of soil and transport of sediment and fugitive dust. These areas represented a continuing source of drifting sand and of coarse and respirable suspended particulate matter. The traditional techniques failed because furrows collapsed and the water holding capacity of the overburden was too low to support seed germination and transplant survival. In this study a variety of wind barriers were evaluated for suppression of sediment transport. Airborne particles were measured with an array of coarse particle samplers at heights of 0.2, 1.0, and 2.0 m above the soil surface. Discrete artificial wind barriers, consisting of widely spaced roughness elements were effective in suppressing fugitive emissions. Wind fences established along the leeward edge of an area of blowing sand, perpendicular to the prevailing wind, significantly decreased fugitive emissions. Control was greatest and precision of the measurements was highest under high wind conditions. These techniques provide rapid and effective suppression of fugitive emissions of soil-derived particles under conditions that resist conventional tillage and revegetation techniques. A simple, indirect procedure for determining local wind velocity erosion thresholds requiring only sampling of wind run and suspended particulate mass compared favorably with direct measurement of saltation as a function of wind velocity.

  6. Biodiversity and concentrations of airborne fungi in large US office buildings from the BASE study

    NASA Astrophysics Data System (ADS)

    Tsai, Feng C.; Macher, Janet M.; Hung, Yun-Yi

    The Building Assessment Survey and Evaluation (BASE) study measured baseline concentrations of airborne fungi in 100 representative US office buildings in 1994-1998. Multiple samples for different sampling durations, sites, and times of the day were aggregated into building-wide indoor and outdoor average concentrations. Fungal concentrations were compared between locations (indoor vs. outdoor), sampling and analytical methods (culture vs. microscopy), and season (summer vs. winter). The arithmetic means (standard deviations) of the indoor/outdoor concentrations of culturable fungi and fungal spores were 100/680 (230/840) CFUm-3 and 270/6540 (1190/6780) sporem-3, respectively. Although fewer groups were observed indoors than outdoors, at lower average concentrations (except in two buildings), site-specific and building-wide indoor measurements had higher coefficients of variation. More groups were seen in summer, and aggregated concentrations tended to be higher than in winter except for culturable Aureobasidium spp. and Botrytis spp. outdoors and non-sporulating fungi in both locations. Rankings of the predominant fungi identified by both methods were similar, but overall indoor and outdoor spore concentrations were approximately 3 and 10 times higher, respectively, than concentrations of culturable fungi. In the 44 buildings with both measurements, the indoor and outdoor total culturable fungi to fungal spore ratios (total C/S ratios) were 1.27 and 0.25, with opposite seasonal patterns. The indoor C/S ratio was higher in summer than in winter (1.47 vs. 0.86; N=29 and 15, respectively), but the outdoor ratio was lower in summer (0.19 vs. 0.36, respectively). Comparison of the number of different fungal groups and individual occurrence in buildings and samples indicated that the outdoor environment and summer season were more diverse, but the proportional contributions of the groups were very similar suggesting that the indoor and outdoor environments were related

  7. Measuring methane concentrations from anthropogenic and natural sources using airborne imaging spectroscopy

    NASA Astrophysics Data System (ADS)

    Thorpe, A. K.; Frankenberg, C.; Roberts, D. A.

    2013-12-01

    Two quantitative retrieval techniques were developed for measuring methane (CH4) enhancements for concentrated plumes using high spatial and moderate spectral resolution data from the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). An Iterative Maximum a Posteriori Differential Optical Absorption Spectroscopy (IMAP-DOAS) algorithm performed well for a homogenous ocean scene containing natural CH4 emissions from the Coal Oil Point (COP) seeps near Santa Barbara, California. A hybrid approach using Singular Value Decomposition (SVD) was particularly effective for terrestrial surfaces given it could better account for highly variable surface reflectance of complex urban environments. These techniques permitted mapping of a distinct plume at COP consistent with known seep locations and local wind direction, with maximum near surface enhancements of 2.85 ppm CH4 above background. At the Inglewood Oil Field, a CH4 plume was observed immediately downwind of two hydrocarbon storage tanks with a maximum concentration of 8.45 ppm above background. Results from a field campaign using the next generation sensor (AVIRISng) and controlled CH4 releases will also be discussed. AVIRIS-like sensors offer the potential to better constrain both CH4 and CO2 emissions on local and regional scales, including sources of increasing concern like industrial point source emissions and fugitive CH4 from the oil and gas industry. Fig. 1. CH4 plumes and measured enhancements for the COP seeps (top) and hydrocarbon storage tanks (bottom).

  8. Composition and Morphology of Major Particle Types from Airborne Measurements during ICE-T and PRADACS Field Studies

    NASA Astrophysics Data System (ADS)

    Venero, I. M.; Mayol-Bracero, O. L.; Anderson, J. R.

    2012-12-01

    As part of the Puerto Rican African Dust and Cloud Study (PRADACS) and the Ice in Clouds Experiment - Tropical (ICE-T), we sampled giant airborne particles to study their elemental composition, morphology, and size distributions. Samples were collected in July 2011 during field measurements performed by NCAR's C-130 aircraft based on St Croix, U.S Virgin Island. The results presented here correspond to the measurements done during research flight #8 (RF8). Aerosol particles with Dp > 1 um were sampled with the Giant Nuclei Impactor and particles with Dp < 1 um were collected with the Wyoming Inlet. Collected particles were later analyzed using an automated scanning electron microscope (SEM) and manual observation by field emission SEM. We identified the chemical composition and morphology of major particle types in filter samples collected at different altitudes (e.g., 300 ft, 1000 ft, and 4500ft). Results from the flight upwind of Puerto Rico show that particles in the giant nuclei size range are dominated by sea salt. Samples collected at altitudes 300 ft and 1000 ft showed the highest number of sea salt particles and the samples collected at higher altitudes (> 4000 ft) showed the highest concentrations of clay material. HYSPLIT back trajectories for all samples showed that the low altitude samples initiated in the free troposphere in the Atlantic Ocean, which may account for the high sea salt content and that the source of the high altitude samples was closer to the Saharan - Sahel desert region and, therefore, these samples possibly had the influence of African dust. Size distribution results for quartz and unreacted sea-salt aerosols collected on the Giant Nuclei Impactor showed that sample RF08 - 12:05 UTM (300 ft) had the largest size value (mean = 2.936 μm) than all the other samples. Additional information was also obtained from the Wyoming Inlet present at the C - 130 aircraft which showed that size distribution results for all particles were smaller in

  9. Evaluation of the area factor used in the RESRAD code for the estimation of airborne contaminant concentrations of finite area sources

    SciTech Connect

    Chang, Y.S.; Yu, C.; Wang, S.K.

    1998-07-01

    The area factor is used in the RESRAD code to estimate the airborne contaminant concentrations for a finite area of contaminated soils. The area factor model used in RESRAD version 5.70 and earlier (referred to as the old area factor) was a simple, but conservative, mixing model that tended to overestimate the airborne concentrations of radionuclide contaminants. An improved and more realistic model for the area factor (referred to here as the new area factor) is described in this report. The new area factor model is designed to reflect site-specific soil characteristics and meteorological conditions. The site-specific parameters considered include the size of the source area, average particle diameter, and average wind speed. Other site-specific parameters (particle density, atmospheric stability, raindrop diameter, and annual precipitation rate) were assumed to be constant. The model uses the Gaussian plume model combined with contaminant removal processes, such as dry and wet deposition of particulates. Area factors estimated with the new model are compared with old area factors that were based on the simple mixing model. In addition, sensitivity analyses are conducted for parameters assumed to be constant. The new area factor model has been incorporated into RESRAD version 5.75 and later.

  10. Control of aerosol contaminants in indoor air: combining the particle concentration reduction with microbial inactivation.

    PubMed

    Grinshpun, Sergey A; Adhikari, Atin; Honda, Takeshi; Kim, Ki Youn; Toivola, Mika; Rao, K S Ramchander; Reponen, Tiina

    2007-01-15

    An indoor air purification technique, which combines unipolar ion emission and photocatalytic oxidation (promoted by a specially designed RCI cell), was investigated in two test chambers, 2.75 m3 and 24.3 m3, using nonbiological and biological challenge aerosols. The reduction in particle concentration was measured size selectively in real-time, and the Air Cleaning Factor and the Clean Air Delivery Rate (CADR) were determined. While testing with virions and bacteria, bioaerosol samples were collected and analyzed, and the microorganism survival rate was determined as a function of exposure time. We observed that the aerosol concentration decreased approximately 10 to approximately 100 times more rapidly when the purifier operated as compared to the natural decay. The data suggest that the tested portable unit operating in approximately 25 m3 non-ventilated room is capable to provide CADR-values more than twice as great than the conventional closed-loop HVAC system with a rating 8 filter. The particle removal occurred due to unipolar ion emission, while the inactivation of viable airborne microorganisms was associated with photocatalytic oxidation. Approximately 90% of initially viable MS2 viruses were inactivated resulting from 10 to 60 min exposure to the photocatalytic oxidation. Approximately 75% of viable B. subtilis spores were inactivated in 10 min, and about 90% or greater after 30 min. The biological and chemical mechanisms that led to the inactivation of stress-resistant airborne viruses and bacterial spores were reviewed. PMID:17310729

  11. Indicators of airborne fungal concentrations in urban homes: understanding the conditions that affect indoor fungal exposures.

    PubMed

    Crawford, Judith A; Rosenbaum, Paula F; Anagnost, Susan E; Hunt, Andrew; Abraham, Jerrold L

    2015-06-01

    Indoor fungal exposure can compromise respiratory health. Low-income urban areas are of concern because of high asthma and allergy rates and housing disrepair. Understanding the conditions that affect indoor fungal exposures is important for assessing health risks and for developing mitigation strategies. We examined the types and concentrations of airborne fungi inside and outside of homes in low-income areas of Syracuse, NY as well as the effect of snow cover on fungal levels. At 103 homes, air samples for viable fungi were collected, occupants were interviewed and homes were inspected for visible mold, musty odors, water problems and other factors. Multivariable logistic regression was used to relate high fungal levels to home conditions. Predominant indoor fungi included Cladosporium, Penicillium, Aspergillus, Alternaria and hyaline unknowns. Basidiomycetes and an uncommon genus Acrodontium were also found frequently due to analysis methods developed for this project. With snow cover, outdoor total fungal levels were depressed and indoor concentrations were three times higher than outdoor on average with a maximum of 29 times higher. Visible mold was related to elevated levels of Penicillium (OR 4.11 95% CI 1.37-14.0) and bacteria (OR 3.79 95% CI 1.41-11.2). Musty, moldy odors were associated with elevated concentrations of total fungi (OR 3.48 95% CI 1.13-11.6) and basidiomycetes. Cockroaches, an indicator of moisture, were associated with elevated levels of Penicillium (OR 3.66 95% CI 1.16-13.1) and Aspergillus (OR 4.36 95% CI 1.60-13.4). Increasing relative humidity was associated with higher concentrations of Penicillium, yeasts and basidiomycetes. Visible mold, musty odors, indoor humidity and cockroaches are modifiable factors that were important determinants of indoor fungal exposures. Indoor air investigators should interpret indoor:outdoor fungal ratios cautiously when snow cover is present. PMID:25725196

  12. Determination of chemical composition of individual airborne particles by SEM/EDX and micro-Raman spectrometry: A review

    NASA Astrophysics Data System (ADS)

    Stefaniak, E. A.; Buczynska, A.; Novakovic, V.; Kuduk, R.; Van Grieken, R.

    2009-04-01

    The strategies for sampling and analysis by SEM/EDX and micro-Raman spectrometry for individual airborne particles analysis as applied at the University of Antwerp (Belgium) by the MITAC group have been reviewed. Microbeam techniques provide detailed information concerning the origin, formation, transport, reactivity, transformation reactions and environmental impact of particulate matter. Moreover, some particles of certain chemical properties have been recognized as a threat for human health and cultural heritage objects. However, the small sizes of particles result in specific problems with respect to single particle analysis. Development of equipment and software for improvement of analysis and quantification are reported.

  13. Airborne Lidar Measurements of Atmospheric Column CO2 Concentration to Cloud Tops

    NASA Astrophysics Data System (ADS)

    Mao, J.; Ramanathan, A. K.; Abshire, J. B.; Kawa, S. R.; Riris, H.; Allan, G. R.; Hasselbrack, W. E.

    2015-12-01

    Globally distributed atmospheric CO2 measurements with high precision, low bias and full seasonal sampling are crucial to advance carbon cycle sciences. However, two thirds of the Earth's surface is typically covered by clouds, and passive remote sensing approaches from space, e.g., OCO-2 and GOSAT, are limited to cloud-free scenes. They are unable to provide useful retrievals in cloudy areas where the photon path-length can't be well characterized. Thus, passive approaches have limited global coverage and poor sampling in cloudy regions, even though some cloudy regions have active carbon surface fluxes. NASA Goddard is developing a pulsed integrated-path, differential absorption (IPDA) lidar approach to measure atmospheric column CO2 concentrations from space as a candidate for NASA's ASCENDS mission. Measurements of time-resolved laser backscatter profiles from the atmosphere also allow this technique to estimate column CO2 and range to cloud tops in addition to those to the ground with precise knowledge of the photon path-length. This allows retrievals of column CO2 concentrations to cloud tops, providing much higher spatial coverage and some information about vertical structure of CO2. This is expected to benefit atmospheric transport process studies, carbon data assimilation in models, and global and regional carbon flux estimation. We show some preliminary results of the all-sky retrieval capability using airborne lidar measurements from the 2011, 2013 and 2014 ASCENDS airborne campaigns on the NASA DC-8. These show retrievals of atmospheric CO2 over low-level marine stratus clouds, cumulus clouds at the top of planetary boundary layer, some mid-level clouds and visually thin high-level cirrus clouds. The CO2 retrievals from the lidar are validated against in-situ measurements and compared to Goddard PCTM model simulations. Lidar cloud slicing to derive CO2 abundance in the planetary boundary layer and free troposphere also has been demonstrated. The

  14. Vertical particle concentration profiles around urban office buildings

    NASA Astrophysics Data System (ADS)

    Quang, T. N.; He, C.; Morawska, L.; Knibbs, L. D.; Falk, M.

    2012-06-01

    Despite its role in determining both indoor and outdoor human exposure to anthropogenic particles, there is limited information describing vertical profiles of particle concentrations in urban environments, especially for ultrafine particles. Furthermore, the results of the few studies performed have been inconsistent. As such, this study aimed to assess the influence of vehicle emissions and nucleation formation on particle characteristics (particle number size distribution - PNSD and PM2.5 concentration) at different heights around three urban office buildings located next to busy roads in Brisbane, Australia, and place these results in the broader context of the existing literature. Two sets of instruments were used to simultaneously measure PNSD, particle number (PN) and PM2.5 concentrations, respectively, for up to three weeks at each building. The results showed that both PNSD and PM2.5 concentration around building envelopes were influenced by vehicle emissions and new particle formation, and that they exhibited variability across the three different office buildings. During nucleation events, PN concentration in size range of <30 nm and total PN concentration increased (7-65% and 5-46%, respectively), while PM2.5 concentration decreased (36-52%) with height. This study has shown an under acknowledged role for nucleation in producing particles that can affect large numbers of people, due to the high density and occupancy of urban office buildings and the fact that the vast majority of people's time is spent indoors. These findings highlight important new information related to the previously overlooked role of particle formation in the urban atmosphere and its potential effects on selection of air intake locations and appropriate filter types when designing or upgrading mechanical ventilation systems in urban office buildings. The results also serve to better define particle behaviour and variability around building envelopes, which has implications for

  15. Airborne Pollen Concentrations and Emergency Room Visits for Myocardial Infarction: A Multicity Case-Crossover Study in Ontario, Canada.

    PubMed

    Weichenthal, Scott; Lavigne, Eric; Villeneuve, Paul J; Reeves, François

    2016-04-01

    Few studies have examined the acute cardiovascular effects of airborne allergens. We conducted a case-crossover study to evaluate the relationship between airborne allergen concentrations and emergency room visits for myocardial infarction (MI) in Ontario, Canada. In total, 17,960 cases of MI were identified between the months of April and October during the years 2004-2011. Daily mean aeroallergen concentrations (pollen and mold spores) were assigned to case and control periods using central-site monitors in each city along with daily measurements of meteorological data and air pollution (nitrogen dioxide and ozone). Odds ratios and their 95% confidence intervals were estimated using conditional logistic regression models adjusting for time-varying covariates. Risk of MI was 5.5% higher (95% confidence interval (CI): 3.4, 7.6) on days in the highest tertile of total pollen concentrations compared with days in the lowest tertile, and a significant concentration-response trend was observed (P < 0.001). Higher MI risk was limited to same-day pollen concentrations, with the largest risks being observed during May (odds ratio = 1.16, 95% CI: 1.00, 1.35) and June (odds ratio = 1.10, 95% CI: 1.00, 1.22), when tree and grass pollen are most common. Mold spore concentrations were not associated with MI. Our findings suggest that airborne pollen might represent a previously unidentified environmental risk factor for myocardial infarction. PMID:26934896

  16. Airborne hyperspectral imaging for sensing phosphorus concentration in the Lake Okeechobee drainage basin

    NASA Astrophysics Data System (ADS)

    Bogrekci, Ismail; Lee, Won Suk; Jordan, Jonathan D.

    2005-05-01

    Eutrophication disturbs the ecological balance in the Lake Okeechobee due to high concentration of phosphorus emanated from the regions in the lake's drainage basin. Ability of measuring phosphorus (P) concentrations of water in the Lake Okeechobee itself is very important. Furthermore, monitoring P in its drainage basins is crucial in order to find the cause of P loading and contributing regions. Also, inexpensive real-time sensing capability for a large area in a short time would help scientist, government agents, and civilians to understand the causes, spot the high-risk areas, and develop management practices for restoring the natural equilibrium. In order to measure P concentrations in the Lake Okeechobee drainage basin, airborne hyperspectral images were taken from five representative target sites by deploying a modified queen air twin engine aircraft. Each flight line covered a swath of approximately 365 m wide. Spatial resolution was about 1 m. Spectral range covered was between 412.65 and 991.82 nm with an approximate of 5 nm spectral resolution. Ground truthing was conducted to collect soil and vegetation samples, GPS coordinates of each location, and reflectance measurement of each sample. On the ground, spectral reflectance was measured using a handheld spectrometer in 400-2500 nm. The samples were sent to a laboratory for chemical analysis. Also diffuse reflectance of the samples was measured in a laboratory setting using a spectrophotometer with an integrating sphere. Images were geocorrected and rectified to reduce geometric effect. Calibration of images was conducted to obtain actual reflectance of the target area. Score, SAM (Spectral Angle Mapping), SFF (Spectral Feature Fitting) were computed for spectral matching with image derived spectral library.

  17. Apparatus and methods for monitoring the concentrations of hazardous airborne substances, especially lead

    DOEpatents

    Zaromb, Solomon

    2004-07-13

    Air is sampled at a rate in excess of 100 L/min, preferably at 200-300 L/min, so as to collect therefrom a substantial fraction, i.e., at least 20%, preferably 60-100%, of airborne particulates. A substance of interest (analyte), such as lead, is rapidly solubilized from the the collected particulates into a sample of liquid extractant, and the concentration of the analyte in the extractant sample is determined. The high-rate air sampling and particulate collection may be effected with a high-throughput filter cartridge or with a recently developed portable high-throughput liquid-absorption air sampler. Rapid solubilization of lead is achieved by a liquid extractant comprising 0.1-1 M of acetic acid or acetate, preferably at a pH of 5 or less and preferably with inclusion of 1-10% of hydrogen peroxide. Rapid determination of the lead content in the liquid extractant may be effected with a colorimetric or an electroanalytical analyzer.

  18. Comparison of Size and Geography of Airborne Tungsten Particles in Fallon, Nevada, and Sweet Home, Oregon, with Implications for Public Health

    PubMed Central

    Sheppard, Paul R.; Bierman, Brian J.; Rhodes, Kent; Ridenour, Gary; Witten, Mark L.

    2012-01-01

    To improve understanding of possible connections between airborne tungsten and public health, size and geography of airborne tungsten particles collected in Fallon, Nevada, and Sweet Home, Oregon, were compared. Both towns have industrial tungsten facilities, but only Fallon has experienced a cluster of childhood leukemia. Fallon and Sweet Home are similar to one another by their particles of airborne tungsten being generally small in size. Meteorologically, much, if not most, of residential Fallon is downwind of its hard metal facility for at least some fraction of time at the annual scale, whereas little of residential Sweet Home is downwind of its tungsten facility. Geographically, most Fallon residents potentially spend time daily within an environment containing elevated levels of airborne tungsten. In contrast, few Sweet Home residents potentially spend time daily within an airborne environment with elevated levels of airborne tungsten. Although it cannot be concluded from environmental data alone that elevated airborne tungsten causes childhood leukemia, the lack of excessive cancer in Sweet Home cannot logically be used to dismiss the possibility of airborne tungsten as a factor in the cluster of childhood leukemia in Fallon. Detailed modeling of all variables affecting airborne loadings of heavy metals would be needed to legitimately compare human exposures to airborne tungsten in Fallon and Sweet Home. PMID:22523506

  19. Measurements of Br/Pb Ratios in Airborne Particles from Car Exhaust

    NASA Astrophysics Data System (ADS)

    Öblad, M.; Selin, E.

    1985-10-01

    Concentrations of particulate bromine and lead have been measured during one summer and one winter period. The measurements were made simultaneously in five sites in a city on the Swedish west coast. A rural site about 60 km from the city was used to measure the background aerosol. Aerosol sampling was made with six dichotomous virtual impactors, which fractionate the aerosol into two modes, one fine particle mode (aerodynamic diameter, a.d. < 3.5 μm) and one coarse particle mode (3.5 μm < a.d. < 18 μm). The aerosol was collected onto thin teflon filters. Element concentrations were obtained by Energy Dispersive X-Ray Fluorescence Analysis. The element concentrations were related to air mass trajectories. The Br/Pb ratio proved to be the same on a given date for the city sites and the background site. A dependence on the air mass history was found, suggesting that it is the quality of the air basin in the region that influences the Br/Pb ratio even for fresh car exhaust. The Br/Pb ratio was the same for fine and coarse particles, indicating that the ratio is determined before coagulation with larger particles occur. The ratios between coarse and fine particles containing lead and bromine respectively were also studied. The results suggest that lead and bromine are actually attached to the same particles.

  20. Modeling the impact of sea-spray on particle concentrations in a coastal city

    SciTech Connect

    Pryor, S C; Barthelmie, R J; Schoof, J T; Binkowski, F S; Monache, L D; Stull, R B

    2006-04-19

    An atmospheric chemistry-transport model is used to assess the impacts of sea-spray chemistry on the particle composition in and downwind of a coastal city--Vancouver, British Columbia. Reactions in/on sea-spray affect the entire particle ensemble and particularly the size distribution of particle nitrate. Urban air quality, and particularly airborne particles, is a major concern in terms of human health impacts. Sea-spray is known to be a major component of the particle ensemble at coastal sites yet relatively few air quality models include the interaction of gases with sea-spray and the fate of the particles produced. Sea-spray is not an inert addition to the particle ensemble because heterogeneous chemistry in/on sea-spray droplets changes the droplets composition and the particle size distribution, which impacts deposition and the ion balance in different particle size fractions. It is shown that the ISOPART model is capable of simulating gas and particle concentrations in the coastal metropolis of Vancouver and the surrounding valley. It is also demonstrated that to accurately simulate ambient concentrations of particles and reactive/soluble gases in a coastal valley it is absolutely critical to include heterogeneous chemistry in/on sea-spray. Partitioning of total particle-NO{sub 3}{sup -} between sea-spray and NH{sub 4}NO{sub 3} is highly sensitive to the amount of sea-spray present, and hence the initial vertical profile, sea-spray source functions [48] and the wind speed. When a fixed wind speed is used to initialize the sea-spray vertical profiles, as expected, the sea-spray concentration decays with distance inland, but the particle-NO{sub 3}{sup -} concentration decays more slowly because it is also a function of the uptake rate for HNO{sub 3}. The simulation results imply model analyses of air quality in coastal cities conducted without inclusion of sea-spray interactions may yield highly misleading results in terms of emission sensitivities of the PM

  1. Culturability and concentration of indoor and outdoor airborne fungi in six single-family homes

    PubMed Central

    Lee, Taekhee; Grinshpun, Sergey A.; Martuzevicius, Dainius; Adhikari, Atin; Crawford, Carlos M.; Reponen, Tiina

    2008-01-01

    In this study, the culturability of indoor and outdoor airborne fungi was determined through long-term sampling (24-h) using a Button Personal Inhalable Aerosol Sampler. The air samples were collected during three seasons in six Cincinnati area homes that were free from moisture damage or visible mold. Cultivation and total microscopic enumeration methods were employed for the sample analysis. The geometric means of indoor and outdoor culturable fungal concentrations were 88 and 102 colony-forming units (CFU) m-3, respectively, with a geometric mean of the I/O ratio equal to 0.66. Overall, 26 genera of culturable fungi were recovered from the indoor and outdoor samples. For total fungal spores, the indoor and outdoor geometric means were 211 and 605 spores m-3, respectively, with a geometric mean of I/O ratio equal to 0.32. The identification revealed 37 fungal genera from indoor and outdoor samples based on the total spore analysis. Indoor and outdoor concentrations of culturable and total fungal spores showed significant correlations (r = 0.655, p<0.0001 and r = 0.633, p<0.0001, respectively). The indoor and outdoor median viabilities of fungi were 55% and 25%, respectively, which indicates that indoor environment provides more favorable survival conditions for the aerosolized fungi. Among the seasons, the highest indoor and outdoor culturability of fungi was observed in the fall. Cladosporium had a highest median value of culturability (38% and 33% for indoor and outdoor, respectively) followed by Aspergillus/Penicillium (9% and 2%) among predominant genera of fungi. Increased culturability of fungi inside the homes may have important implications because of the potential increase in the release of allergens from viable spores and pathogenicity of viable fungi on immunocompromised individuals. PMID:18458748

  2. Culturability and concentration of indoor and outdoor airborne fungi in six single-family homes

    NASA Astrophysics Data System (ADS)

    Lee, Taekhee; Grinshpun, Sergey A.; Martuzevicius, Dainius; Adhikari, Atin; Crawford, Carlos M.; Reponen, Tiina

    In this study, the culturability of indoor and outdoor airborne fungi was determined through long-term sampling (24-h) using a Button Personal Inhalable Aerosol Sampler. The air samples were collected during three seasons in six Cincinnati area homes that were free from moisture damage or visible mold. Cultivation and total microscopic enumeration methods were employed for the sample analysis. The geometric means of indoor and outdoor culturable fungal concentrations were 88 and 102 colony-forming units (CFU) m -3, respectively, with a geometric mean of the I/ O ratio equal to 0.66. Overall, 26 genera of culturable fungi were recovered from the indoor and outdoor samples. For total fungal spores, the indoor and outdoor geometric means were 211 and 605 spores m -3, respectively, with a geometric mean of I/ O ratio equal to 0.32. The identification revealed 37 fungal genera from indoor and outdoor samples based on the total spore analysis. Indoor and outdoor concentrations of culturable and total fungal spores showed significant correlations ( r=0.655, p<0.0001 and r=0.633, p<0.0001, respectively). The indoor and outdoor median viabilities of fungi were 55% and 25%, respectively, which indicates that indoor environment provides more favorable survival conditions for the aerosolized fungi. Among the seasons, the highest indoor and outdoor culturability of fungi was observed in the fall. Cladosporium had a highest median value of culturability (38% and 33% for indoor and outdoor, respectively) followed by Aspergillus/Penicillium (9% and 2%) among predominant genera of fungi. Increased culturability of fungi inside the homes may have important implications because of the potential increase in the release of allergens from viable spores and pathogenicity of viable fungi on immunocompromised individuals.

  3. DIFFERENTIAL LUNG GENE EXPRESSION IN IMMUNOLOGICALLY-CHALLENGED RATS EXPOSED TO CONCENTRATED AIRBORNE PARTICULATES

    EPA Science Inventory

    Children residing in urbanized areas suffer disproportionately higher asthma-related morbidity and mortality. One explanation is that inner city children are exposured to higher levels of environmental asthma triggers such as airborne particulate matter. To elucidate gene-environ...

  4. MEMS-based silicon cantilevers with integrated electrothermal heaters for airborne ultrafine particle sensing

    NASA Astrophysics Data System (ADS)

    Wasisto, Hutomo Suryo; Merzsch, Stephan; Waag, Andreas; Peiner, Erwin

    2013-05-01

    The development of low-cost and low-power MEMS-based cantilever sensors for possible application in hand-held airborne ultrafine particle monitors is described in this work. The proposed resonant sensors are realized by silicon bulk micromachining technology with electrothermal excitation, piezoresistive frequency readout, and electrostatic particle collection elements integrated and constructed in the same sensor fabrication process step of boron diffusion. Built-in heating resistor and full Wheatstone bridge are set close to the cantilever clamp end for effective excitation and sensing, respectively, of beam deflection. Meanwhile, the particle collection electrode is located at the cantilever free end. A 300 μm-thick, phosphorus-doped silicon bulk wafer is used instead of silicon-on-insulator (SOI) as the starting material for the sensors to reduce the fabrication costs. To etch and release the cantilevers from the substrate, inductively coupled plasma (ICP) cryogenic dry etching is utilized. By controlling the etching parameters (e.g., temperature, oxygen content, and duration), cantilever structures with thicknesses down to 10 - 20 μm are yielded. In the sensor characterization, the heating resistor is heated and generating thermal waves which induce thermal expansion and further cause mechanical bending strain in the out-of-plane direction. A resonant frequency of 114.08 +/- 0.04 kHz and a quality factor of 1302 +/- 267 are measured in air for a fabricated rectangular cantilever (500x100x13.5 μm3). Owing to its low power consumption of a few milliwatts, this electrothermal cantilever is suitable for replacing the current external piezoelectric stack actuator in the next generation of the miniaturized cantilever-based nanoparticle detector (CANTOR).

  5. Saharan Dust Particle Size And Concentration Distribution In Central Ghana

    NASA Astrophysics Data System (ADS)

    Sunnu, A. K.

    2010-12-01

    A.K. Sunnu*, G. M. Afeti* and F. Resch+ *Department of Mechanical Engineering, Kwame Nkrumah University of Science and Technology (KNUST) Kumasi, Ghana. E-mail: albertsunnu@yahoo.com +Laboratoire Lepi, ISITV-Université du Sud Toulon-Var, 83162 La Valette cedex, France E-mail: resch@univ-tln.fr Keywords: Atmospheric aerosol; Saharan dust; Particle size distributions; Particle concentrations. Abstract The Saharan dust that is transported and deposited over many countries in the West African atmospheric environment (5°N), every year, during the months of November to March, known locally as the Harmattan season, have been studied over a 13-year period, between 1996 and 2009, using a location at Kumasi in central Ghana (6° 40'N, 1° 34'W) as the reference geographical point. The suspended Saharan dust particles were sampled by an optical particle counter, and the particle size distributions and concentrations were analysed. The counter gives the total dust loads as number of particles per unit volume of air. The optical particle counter used did not discriminate the smoke fractions (due to spontaneous bush fires during the dry season) from the Saharan dust. Within the particle size range measured (0.5 μm-25 μm.), the average inter-annual mean particle diameter, number and mass concentrations during the northern winter months of January and February were determined. The average daily number concentrations ranged from 15 particles/cm3 to 63 particles/cm3 with an average of 31 particles/cm3. The average daily mass concentrations ranged from 122 μg/m3 to 1344 μg/m3 with an average of 532 μg/m3. The measured particle concentrations outside the winter period were consistently less than 10 cm-3. The overall dust mean particle diameter, analyzed from the peak representative Harmattan periods over the 13-year period, ranged from 0.89 μm to 2.43 μm with an average of 1.5 μm ± 0.5. The particle size distributions exhibited the typical distribution pattern for

  6. What We are Learning about Airborne Particles from MISR Multi-angle Imaging

    NASA Astrophysics Data System (ADS)

    Kahn, Ralph

    The NASA Earth Observing System’s Multi-angle Imaging SpectroRadiometer (MISR) instrument has been collecting global observations in 36 angular-spectral channels about once per week for over 14 years. Regarding airborne particles, MISR is contributing in three broad areas: (1) aerosol optical depth (AOD), especially over land surface, including bright desert, (2) wildfire smoke, desert dust, and volcanic ash injection and near-source plume height, and (3) aerosol type, the aggregate of qualitative constraints on particle size, shape, and single-scattering albedo (SSA). Early advances in the retrieval of these quantities focused on AOD, for which surface-based sun photometers provided a global network of ground truth, and plume height, for which ground-based and airborne lidar offered near-coincident validation data. MSIR monthly, global AOD products contributed directly to the advances in modeling aerosol impacts on climate made between the Inter-governmental Panel on Climate Change (IPCC) third and fourth assessment reports. MISR stereo-derived plume heights are now being used to constrain source inventories for the AeroCom aerosol-climate modeling effort. The remaining challenge for the MISR aerosol effort is to refine and validate our global aerosol type product. Unlike AOD and plume height, aerosol type as retrieved by MISR is a qualitative classification derived from multi-dimensional constraints, so evaluation must be done on a categorical basis. Coincident aerosol type validation data are far less common than for AOD, and, except for rare Golden Days during aircraft field campaigns, amount to remote sensing retrievals from suborbital instruments having uncertainties comparable to those from the MISR product itself. And satellite remote sensing retrievals of aerosol type are much more sensitive to scene conditions such as surface variability and AOD than either AOD or plume height. MISR aerosol type retrieval capability and information content have been

  7. Number concentrations of fine and ultrafine particles containing metals

    NASA Astrophysics Data System (ADS)

    Tolocka, Michael P.; Lake, Derek A.; Johnston, Murray V.; Wexler, Anthony S.

    Typical classification schemes for large data sets of single-particle mass spectra involve statistical or neural network analysis. In this work, a new approach is evaluated in which particle spectra are pre-selected on the basis of an above threshold signal intensity at a specified m/ z (mass to charge ratio). This provides a simple way to identify candidate particles that may contain the specific chemical component associated with that m/ z. Once selected, the candidate particle spectra are then classified by the fast adaptive resonance algorithm, ART 2-a, to confirm the presence of the targeted component in the particle and to study the intra-particle associations with other chemical components. This approach is used to characterize metals in a 75,000 particle data set obtained in Baltimore, Maryland. Particles containing a specific metal are identified and then used to determine the size distribution, number concentration, time/wind dependencies and intra-particle correlations with other metals. Four representative elements are considered in this study: vanadium, iron, arsenic and lead. Number concentrations of ambient particles containing these elements can exceed 10,000 particles cm -3 at the measurement site. Vanadium, a primary marker for fuel oil combustion, is observed from all wind directions during this time period. Iron and lead are observed from the east-northeast. Most particles from this direction that contain iron also contain lead and most particles that contain lead also contain iron, suggesting a common emission source for the two. Arsenic and lead are observed from the south-southeast. Particles from this direction contain either arsenic or lead but rarely both, suggesting different sources for each element.

  8. Airborne in-situ spectral characterization and concentration estimates of fluorescent organics as a function of depth

    NASA Technical Reports Server (NTRS)

    Tittle, R. A.

    1988-01-01

    The primary purpose of many in-situ airborne light scattering experiments in natural waters is to spectrally characterize the subsurface fluorescent organics and estimate their relative concentrations. This is often done by shining a laser beam into the water and monitoring its subsurface return signal. To do this with the proper interpretation, depth must be taken into account. If one disregards depth dependence when taking such estimates, both their spectral characteristics and their concentrations estimates can be rather ambiguous. A simple airborne lidar configuration is used to detect the subsurface return signal from a particular depth and wavelength. Underwater scatterometer were employed to show that in-situ subsurface organics are very sensitive to depth, but they also require the use of slow moving boats to cover large sample areas. Also, their very entry into the water disturbs the sample it is measuring. The method described is superior and simplest to any employed thus far.

  9. Personal exposure to airborne ultrafine particles in the urban area of Milan

    NASA Astrophysics Data System (ADS)

    Cattaneo, A.; Garramone, G.; Taronna, M.; Peruzzo, C.; Cavallo, D. M.

    2009-02-01

    The relevance of health effects related to ultrafine particles (UFPs; aerodynamic diameter < 100 nm) can be better evaluated using high-resolution strategies for measuring particle number concentrations. In this study, two different portable Condensation Particle Counters (CPCs) were used to measure personal exposure to UFPs in the central area of Milan for one week period during spring, with three sampling sessions per day. Experimental data were continuously collected along an established urban pathway, moving afoot or by different private and public means of transport. Correlation analysis between data measured by two CPCs was performed and general results showed a good agreement, especially at concentrations lower than 2×105 particles /cm3. UFPs measures were divided on the basis of crossed environments or micro-environments, days of the week and day time (hours). The highest measured mean concentrations and data variability were observed during walking time and moving on motorized vehicles (bus and car), indicating that the highest exposure to UFPs can be reached near motorized traffic. The lowest exposures were observed in green areas and in office microenvironments. An appreciable difference between working and non-working days was observed. Concentration patterns and variation by days of the week and time periods appears related to time trends in traffic intensity.

  10. Measurement of airborne gunshot particles in a ballistics laboratory by sector field inductively coupled plasma mass spectrometry.

    PubMed

    Diaz, Ernesto; Sarkis, Jorge E Souza; Viebig, Sônia; Saldiva, Paulo

    2012-01-10

    The present study aimed determines lead (Pb), antimony (Sb) and barium (Ba) as the major elements present in GSR in the environmental air of the Ballistics Laboratory of the São Paulo Criminalistics Institute (I.C.-S.P.), São Paulo, SP, Brazil. Micro environmental monitors (mini samplers) were located at selected places. The PM(2.5) fraction of this airborne was collected in, previously weighted filters, and analyzed by sector field inductively coupled plasma mass spectrometer (SF-HR-ICP-MS). The higher values of the airborne lead, antimony and barium, were found at the firing range (lead (Pb): 58.9 μg/m(3); barium (Ba): 6.9 μg/m(3); antimony (Sb): 7.3 μg/m(3)). The mean value of the airborne in this room during 6 monitored days was Pb: 23.1 μg/m(3); Ba: 2.2 μg/m(3); Sb: 1.5 μg/m(3). In the water tank room, the air did not show levels above the limits of concern. In general the airborne lead changed from day to day, but the barium and antimony remained constant. Despite of that, the obtained values suggest that the workers may be exposed to airborne lead concentration that can result in an unhealthy environment and could increase the risk of chronic intoxication. PMID:21831549

  11. Source contributions to atmospheric fine carbon particle concentrations

    NASA Astrophysics Data System (ADS)

    Andrew Gray, H.; Cass, Glen R.

    A Lagrangian particle-in-cell air quality model has been developed that facilitates the study of source contributions to atmospheric fine elemental carbon and fine primary total carbon particle concentrations. Model performance was tested using spatially and temporally resolved emissions and air quality data gathered for this purpose in the Los Angeles area for the year 1982. It was shown that black elemental carbon (EC) particle concentrations in that city were dominated by emissions from diesel engines including both on-highway and off-highway applications. Fine primary total carbon particle concentrations (TC=EC+organic carbon) resulted from the accumulation of small increments from a great variety of emission source types including both gasoline and diesel powered highway vehicles, stationary source fuel oil and gas combustion, industrial processes, paved road dust, fireplaces, cigarettes and food cooking (e.g. charbroilers). Strategies for black elemental carbon particle concentration control will of necessity need to focus on diesel engines, while controls directed at total carbon particle concentrations will have to be diversified over a great many source types.

  12. A study of airborne chrysotile concentrations associated with handling, unpacking, and repacking boxes of automobile clutch discs.

    PubMed

    Jiang, George C T; Madl, Amy K; Ingmundson, Kelsey J; Murbach, Dana M; Fehling, Kurt A; Paustenbach, Dennis J; Finley, Brent L

    2008-06-01

    Although automotive friction products (brakes and manual clutches) historically contained chrysotile asbestos, industrial hygiene surveys and epidemiologic studies of auto mechanics have consistently shown that these workers are not at an increased risk of developing asbestos-related diseases. Airborne asbestos levels during brake repair and brake parts handling have been well-characterized, but the potential exposure to airborne asbestos fibers during the handling of clutch parts has not been examined. In this study, breathing zone samples on the lapel of a volunteer worker (n=100) and area samples at bystander (n=50), remote area (n=25), and ambient (n=9) locations collected during the stacking, unpacking, and repacking of boxes of asbestos-containing clutches, and the subsequent cleanup and clothes handling, were analyzed by phase contrast microscopy (PCM) and transmission electron microscopy (TEM). In addition, fiber morphology and size distribution was evaluated using X-ray diffraction, polarized light microscopy, and ISO analytical methods. It was observed that the (1) airborne asbestos concentrations increased with the number of boxes unpacked and repacked, (2) repetitive stacking of unopened boxes of clutches resulted in higher asbestos concentrations than unpacking and repacking the boxes of clutches, (3) cleanup and clothes handling tasks yielded very low asbestos concentrations. Fiber size and morphology analyses showed that amphibole fibers were not detected in the clutches and that the vast majority (>95%) of the airborne chrysotile fibers were less than 20 microm in length. Applying the ratio of asbestos fibers:total fibers (including non-asbestos) as determined by TEM to the PCM results, it was found that 30-min average airborne chrysotile concentrations (PCM adjusted) were 0.026+/-0.004 f/cc or 0.100+/-0.017 f/cc for a worker unpacking and repacking 1 or 2 boxes of clutches, respectively. The 30-min PCM adjusted average airborne asbestos

  13. Application of Medical Magnetic Resonance Imaging for Particle Concentration Measurement

    NASA Astrophysics Data System (ADS)

    Borup, Daniel; Elkins, Christopher; Eaton, John

    2014-11-01

    Particle transport and deposition in internal flows is important in a range of applications such as dust aggregation in turbine engines and aerosolized medicine deposition in human airways. Unlike optical techniques, Magnetic Resonance Imaging (MRI) is well suited for complex applications in which optical access is not possible. Here we present efforts to measure 3D particle concentration distribution using MRI. Glass particles dispersed in water flow reduce MRI signal from a spin-echo or gradient-echo scanning sequence by decreasing spin density and dephasing the spins present in the fluid. A preliminary experiment was conducted with a particle streak injected at the centerline of a turbulent round pipe flow with a U bend. Measurements confirmed that signal strength was related to particle concentration and showed the effects of gravitational settling and turbulent dispersion. Next, measurements of samples in a mixing chamber were taken. Particle volume fraction was varied and sensitivity to particle/fluid velocity was investigated. These results give a relationship between MRI signal, particle volume fraction, MRI sequence echo time, and spin relaxation parameters that can be used to measure local particle volume fraction in other turbulent flows of interest.

  14. Beryllium solubility in occupational airborne particles: Sequential extraction procedure and workplace application.

    PubMed

    Rousset, Davy; Durand, Thibaut

    2016-01-01

    Modification of an existing sequential extraction procedure for inorganic beryllium species in the particulate matter of emissions and in working areas is described. The speciation protocol was adapted to carry out beryllium extraction in closed-face cassette sampler to take wall deposits into account. This four-step sequential extraction procedure aims to separate beryllium salts, metal, and oxides from airborne particles for individual quantification. Characterization of the beryllium species according to their solubility in air samples may provide information relative to toxicity, which is potentially related to the different beryllium chemical forms. Beryllium salts (BeF(2), BeSO(4)), metallic beryllium (Bemet), and beryllium oxide (BeO) were first individually tested, and then tested in mixtures. Cassettes were spiked with these species and recovery rates were calculated. Quantitative analyses with matched matrix were performed using inductively coupled plasma mass spectrometry (ICP-MS). Method Detection Limits (MDLs) were calculated for the four matrices used in the different extraction steps. In all cases, the MDL was below 4.2 ng/sample. This method is appropriate for assessing occupational exposure to beryllium as the lowest recommended threshold limit values are 0.01 µg.m(-3) in France([) (1) (]) and 0.05 µg.m(-3) in the USA.([ 2 ]) The protocol was then tested on samples from French factories where occupational beryllium exposure was suspected. Beryllium solubility was variable between factories and among the same workplace between different tasks. PMID:26327570

  15. [Ultrafine particle number concentration and size distribution of vehicle exhaust ultrafine particles].

    PubMed

    Lu, Ye-qiang; Chen, Qiu-fang; Sun, Zai; Cai, Zhi-liang; Yang, Wen-jun

    2014-09-01

    Ultrafine particle (UFP) number concentrations obtained from three different vehicles were measured using fast mobility particle sizer (FMPS) and automobile exhaust gas analyzer. UFP number concentration and size distribution were studied at different idle driving speeds. The results showed that at a low idle speed of 800 rmin-1 , the emission particle number concentration was the lowest and showed a increasing trend with the increase of idle speed. The majority of exhaust particles were in Nuclear mode and Aitken mode. The peak sizes were dominated by 10 nm and 50 nm. Particle number concentration showed a significantly sharp increase during the vehicle acceleration process, and was then kept stable when the speed was stable. In the range of 0. 4 m axial distance from the end of the exhaust pipe, the particle number concentration decayed rapidly after dilution, but it was not obvious in the range of 0. 4-1 m. The number concentration was larger than the background concentration. Concentration of exhaust emissions such as CO, HC and NO showed a reducing trend with the increase of idle speed,which was in contrast to the emission trend of particle number concentration. PMID:25518646

  16. Continuum modeling of hydrodynamic particle-particle interactions in microfluidic high-concentration suspensions.

    PubMed

    Ley, Mikkel W H; Bruus, Henrik

    2016-03-23

    A continuum model is established for numerical studies of hydrodynamic particle-particle interactions in microfluidic high-concentration suspensions. A suspension of microparticles placed in a microfluidic channel and influenced by an external force, is described by a continuous particle-concentration field coupled to the continuity and Navier-Stokes equation for the solution. The hydrodynamic interactions are accounted for through the concentration dependence of the suspension viscosity, of the single-particle mobility, and of the momentum transfer from the particles to the suspension. The model is applied on a magnetophoretic and an acoustophoretic system, respectively, and based on the results, we illustrate three main points: (1) for relative particle-to-fluid volume fractions greater than 0.01, the hydrodynamic interaction effects become important through a decreased particle mobility and an increased suspension viscosity. (2) At these high particle concentrations, particle-induced flow rolls occur, which can lead to significant deviations of the advective particle transport relative to that of dilute suspensions. (3) Which interaction mechanism that dominates, depends on the specific flow geometry and the specific external force acting on the particles. PMID:26948344

  17. Airborne polybrominated diphenyl ethers (PBDEs), polybrominated dibenzo-p-dioxins/furans (PBDD/Fs), and dechlorane plus (DP) in concentrated vehicle parking areas.

    PubMed

    Li, Huiru; Liu, Hehuan; Mo, Ligui; Sheng, Guoying; Fu, Jiamo; Peng, Ping'an

    2016-06-01

    This study investigated polybrominated diphenyl ethers (PBDEs), polybrominated dibenzo-p-dioxins/furans (PBDD/Fs), and dechlorane plus (DP) in air around three concentrated vehicle parking areas (underground, indoor, and outdoor) in a metropolitan of South China. The parking areas showed higher concentrations of PBDEs, PBDD/Fs, and DP than their adjacent urban area or distinct congener/isomer profiles, which indicate their local emission sources. The highest PBDE and DP concentrations were found in the outdoor parking lot, which might be related to the heating effect of direct sunlight exposure. Multi-linear regression analysis results suggest that deca-BDEs without noticeable transformation contributed most to airborne PBDEs in all studied areas, followed by penta-BDEs. The statistically lower anti-DP fractions in the urban area than that of commercial product signified its degradation/transformation during transportation. Neither PBDEs nor vehicle exhaust contributed much to airborne PBDD/Fs in the parking areas. There were 68.1-100 % of PBDEs, PBDD/Fs, and DP associated with particles. Logarithms of gas-particle distribution coefficients (K ps) of PBDEs were significantly linear-correlated with those of their sub-cooled vapor pressures (p Ls) and octanol-air partition coefficients (K OAs) in all studied areas. The daily inhalation doses of PBDEs, DP, and PBDD/Fs were individually estimated as 89.7-10,741, 2.05-39.4, and 0.12-4.17 pg kg(-1) day(-1) for employees in the parking areas via Monte Carlo simulation. PMID:26884244

  18. Preferrential Concentration of Particles in Protoplanetary Nebula Turbulence

    NASA Technical Reports Server (NTRS)

    Hartlep, Thomas; Cuzzi, Jeffrey N.

    2015-01-01

    Preferential concentration in turbulence is a process that causes inertial particles to cluster in regions of high strain (in-between high vorticity regions), with specifics depending on their stopping time or Stokes number. This process is thought to be of importance in various problems including cloud droplet formation and aerosol transport in the atmosphere, sprays, and also in the formation of asteroids and comets in protoplanetary nebulae. In protoplanetary nebulae, the initial accretion of primitive bodies from freely-floating particles remains a problematic subject. Traditional growth-by-sticking models encounter a formidable "meter-size barrier" [1] in turbulent nebulae. One scenario that can lead directly from independent nebula particulates to large objects, avoiding the problematic m-km size range, involves formation of dense clumps of aerodynamically selected, typically mm-size particles in protoplanetary turbulence. There is evidence that at least the ordinary chondrite parent bodies were initially composed entirely of a homogeneous mix of such particles generally known as "chondrules" [2]. Thus, while it is arcane, turbulent preferential concentration acting directly on chondrule size particles are worthy of deeper study. Here, we present the statistical determination of particle multiplier distributions from numerical simulations of particle-laden isotopic turbulence, and a cascade model for modeling turbulent concentration at lengthscales and Reynolds numbers not accessible by numerical simulations. We find that the multiplier distributions are scale dependent at the very largest scales but have scale-invariant properties under a particular variable normalization at smaller scales.

  19. Preferential concentration of heavy particles in compressible isotropic turbulence

    NASA Astrophysics Data System (ADS)

    Zhang, Qingqing; Liu, Han; Ma, Zongqiang; Xiao, Zuoli

    2016-05-01

    Numerical simulations of particle-laden compressible isotropic turbulence with Taylor Reynolds number Reλ ˜ 100 are conducted by using a high-order turbulence solver, which is based on high-order compact finite difference method in the whole flow domain and localized artificial diffusivities for discontinuities. For simplicity, only one-way coupling (i.e., the influence of fluid on particles) between the carrier flow and particles is considered. The focus is on the study of the preferential concentration of heavy particles in dissipative scale of turbulence and the underlying mechanisms. Firstly, the effect of Stokes number (St) on the particle distribution in flow of Mach 1.01 (referred to as high-Mach-number case in this study) is investigated as a necessary supplementation for the previous studies in incompressible and weakly compressible flows. It turns out that heavy particles with Stokes number close to unity exhibit the strongest preferential concentration, which is in agreement with the observation in incompressible flow. All types of heavy particles have a tendency to accumulate in high-density regions of the background flow. While all kinds of particles dominantly collect in low-vorticity regions, intermediate and large particles (St = 1 and St = 5) are also found to collect in high-vorticity regions behind the randomly formed shocklets. Secondly, the impact of turbulent Mach number (Mt) (or the compressibility) of the carrier flow on the spatial distribution of the particles with St = 1 is discussed using the simulated compressible flows with Mt being 0.22, 0.68, and 1.01, respectively. In low-Mach-number flow, particles tend to concentrate in regions of low vorticity due to the centrifuge effect of vortices and particle concentration decreases monotonically with the increasing vorticity magnitude. As Mach number increases, the degree of particle clustering is slightly weakened in low-vorticity regions but is enhanced in high-vorticity regions, which

  20. Spatial-temporal variations of particle number concentrations between a busy street and the urban background

    NASA Astrophysics Data System (ADS)

    Dos Santos-Juusela, Vanessa; Petäjä, Tuukka; Kousa, Anu; Hämeri, Kaarle

    2013-11-01

    To estimate spatial-temporal variations of ultrafine particles (UFP) in Helsinki, we measured particle total number concentrations (PNC) continuously in a busy street and an urban background site for six months, using condensation particle counters (CPC). We also evaluated the effects of temperature, wind speed and wind direction on PNC, as well as the correlation between PNC and PM2.5, PM10 and black carbon (BC) at the street. We found that on weekdays, hourly median PNC were highly correlated with BC (r = 0.88), moderately correlated with PM2.5 (r = 0.59) and weakly correlated with PM10 (r = 0.22). Number concentrations at the street were inversely proportional to temperature and wind speed, and highly dependent on wind direction. The highest PNC occurred during northeastern winds while the lowest occurred during southwestern winds. As these wind directions are nearly perpendicular to the street axis, the formation of wind vortices may have influenced the dispersion of UFP in the site. Although the temporal correlation for PNC was moderately high between the sites (r = 0.71), the median concentration at the street was 3 times higher than the urban background levels. The results indicate that people living or passing by the busy street are exposed to UFP concentrations well above the urban background levels. Thus, the study suggests that urban microenvironments should be considered in epidemiological studies. In addition the results emphasize that regulations based solely on PM2.5 and PM10 concentrations may be insufficient for preventing the adverse health effects of airborne particles.

  1. Crop harvest in Denmark and Central Europe contributes to the local load of airborne Alternaria spore concentrations in Copenhagen

    NASA Astrophysics Data System (ADS)

    Skjøth, C. A.; Sommer, J.; Frederiksen, L.; Gosewinkel Karlson, U.

    2012-11-01

    This study examines the hypothesis that Danish agricultural areas are the main source of airborne Alternaria spores in Copenhagen, Denmark. We suggest that the contribution to the overall load is mainly local or regional, but with intermittent long distance transport (LDT) from more remote agricultural areas. This hypothesis is supported by investigating a 10 yr bi-hourly record of Alternaria spores in the air from Copenhagen. This record shows 232 clinically relevant episodes (daily average spore concentration above 100 m-3) with a distinct daily profile. The data analysis also revealed potential LDT episodes almost every year. A source map and analysis of atmospheric transport suggest that LDT always originates from the main agricultural areas in Central Europe. A dedicated emission study in cereal crops under harvest during 2010 also supports our hypothesis. The emission study showed that although the fields had been treated against fungal infections, harvesting still produced large amounts of airborne fungal spores. It is likely that such harvesting periods can cause clinically relevant levels of fungal spores in the atmosphere. Our findings suggest that crop harvest in Central Europe causes episodes of high airborne Alternaria spore concentrations in Copenhagen as well as other urban areas in this region. It is likely that such episodes could be simulated using atmospheric transport models.

  2. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers.

    PubMed

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-04-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. PMID:26773821

  3. Particle size distribution of airborne Aspergillus fumigatus spores emitted from compost using membrane filtration

    NASA Astrophysics Data System (ADS)

    Deacon, L. J.; Pankhurst, L. J.; Drew, G. H.; Hayes, E. T.; Jackson, S.; Longhurst, P. J.; Longhurst, J. W. S.; Liu, J.; Pollard, S. J. T.; Tyrrel, S. F.

    Information on the particle size distribution of bioaerosols emitted from open air composting operations is valuable in evaluating potential health impacts and is a requirement for improved dispersion simulation modelling. The membrane filter method was used to study the particle size distribution of Aspergillus fumigatus spores in air 50 m downwind of a green waste compost screening operation at a commercial facility. The highest concentrations (approximately 8 × 10 4 CFU m -3) of culturable spores were found on filters with pore diameters in the range 1-2 μm which suggests that the majority of spores are emitted as single cells. The findings were compared to published data collected using an Andersen sampler. Results were significantly correlated ( p < 0.01) indicating that the two methods are directly comparable across all particles sizes for Aspergillus spores.

  4. EVALUATION OF AIRBORNE ASBESTOS CONCENTRATIONS BEFORE AND DURING AND O&M ACTIVITY: A CASE STUDY

    EPA Science Inventory

    The current lack of information regarding the impact of O&M activities on the potential for asbestos exposure to building staff and occupants prompted this study. This report presents a statistical evaluation of airborne asbestos data collected before and during an O&M activity i...

  5. ESTIMATING DOWNWIND CONCENTRATIONS OF VIABLE AIRBORNE MICROORGANISMS IN DYNAMIC ATMOSPHERIC CONDITIONS (JOURNAL VERSION)

    EPA Science Inventory

    A Gaussian plume model has been modified to include an airborne microbial survival term that is a best-fit function of laboratory experimental data of weather variables. The model has been included in an algorithm using microbial source strength and local hourly mean weather data...

  6. Opposed-flow virtual cyclone for particle concentration

    SciTech Connect

    Rader, Daniel J.; Torczynski, John R.

    2000-12-05

    An opposed-flow virtual cyclone for aerosol collation which can accurately collect, classify, and concentrate (enrich) particles in a specific size range. The opposed-flow virtual cyclone is a variation on the virtual cyclone and has its inherent advantages (no-impact particle separation in a simple geometry), while providing a more robust design for concentrating particles in a flow-through type system. The opposed-flow virtual cyclone consists of two geometrically similar virtual cyclones arranged such that their inlet jets are inwardly directed and symmetrically opposed relative to a plane of symmetry located between the two inlet slits. A top plate bounds both jets on the "top" side of the inlets, while the other or lower wall curves "down" and away from each inlet jet. Each inlet jet will follow the adjacent lower wall as it turns away, and that particles will be transferred away from the wall and towards the symmetry plane by centrifugal action. After turning, the two jets merge smoothly along the symmetry line and flow parallel to it through the throat. Particles are transferred from the main flows, across a dividing streamline, and into a central recirculating region, where particle concentrations become greatly increased relative to the main stream.

  7. Quantum states of two particles on concentric spheres

    NASA Astrophysics Data System (ADS)

    Ezra, Gregory S.; Berry, R. Stephen

    1983-10-01

    The model of two particles on a sphere is extended to two particles on concentric spheres (POCS). The quantum states are found for two electrons, one on a sphere of radius 10 a.u. (simulating the shell n=3 in He) and the other, on spheres of 10, 15, 25, 50, and 100 a.u. The eigenvalues and densities ρ(θ12) exhibit a transition from collective, moleculelike behavior to independent-particle-like behavior with Russell-Saunders coupling. The parallel problem of two particles with electron masses interacting via a repulsive Gaussian potential is also treated and a similar transition from collective to independent-particle behavior found. The principal difference between the two cases is only the region of radius of the larger sphere where the transition occurs.

  8. Variability of aerosol particle number concentrations observed over the western Pacific in the spring of 2009

    NASA Astrophysics Data System (ADS)

    Takegawa, N.; Moteki, N.; Oshima, N.; Koike, M.; Kita, K.; Shimizu, A.; Sugimoto, N.; Kondo, Y.

    2014-12-01

    Airborne measurements of aerosols were conducted over the western Pacific in the spring of 2009 during the Aerosol Radiative Forcing in East Asia (A-FORCE) aircraft campaign. The A-FORCE flights intensively covered an important vertical-latitudinal range in the outflow region of East Asia (0-9 km altitude; 27°N-38°N). This paper presents the variability of aerosol particle number concentrations obtained by condensation particle counters and a Single-Particle Soot Photometer (SP2), with the focus on those in the free troposphere. The number concentration data include total condensation nuclei with particle diameters (dp) larger than 10 nm (total CN10), PM0.17-CN10 (dp ~10-130 nm), and SP2 black carbon (NBC; dp ~75-850 nm). Large increases in total CN10 that were not associated with NBC were observed in the free troposphere, suggesting influences from new particle formation (NPF). Statistical characteristics of total CN10, PM0.17-CN10, and NBC in the lower troposphere (LT; 0-3 km), middle troposphere (MT; 3-6 km), and upper troposphere (UT; 6-9 km) are investigated. The correlation between total CN10 and NBC, along with the ratio of PM0.17 to total CN10 and carbon monoxide mixing ratio (CO), is used to interpret the observed variability. The median concentrations of total CN10 and PM0.17-CN10 in the UT were higher than those in the MT by a factor of ~1.4 and ~1.6, respectively. We attribute the enhancements of CN10 in the UT to NPF. Possible mechanisms affecting NPF in the free troposphere are discussed.

  9. Airborne concentrations of metals and total dust during solid catalyst loading and unloading operations at a petroleum refinery.

    PubMed

    Lewis, Ryan C; Gaffney, Shannon H; Le, Matthew H; Unice, Ken M; Paustenbach, Dennis J

    2012-09-01

    Workers handle catalysts extensively at petroleum refineries throughout the world each year; however, little information is available regarding the airborne concentrations and plausible exposures during this type of work. In this paper, we evaluated the airborne concentrations of 15 metals and total dust generated during solid catalyst loading and unloading operations at one of the largest petroleum refineries in the world using historical industrial hygiene samples collected between 1989 and 2006. The total dust and metals, which included aluminum, cadmium, chromium, cobalt, copper, iron, lead, manganese, molybdenum, nickel, platinum, silicon, silver, vanadium, and zinc, were evaluated in relation to the handling of four different types of solid catalysts associated with three major types of catalytic processes. Consideration was given to the known components of the solid catalysts and any metals that were likely deposited onto them during use. A total of 180 analytical results were included in this analysis, representing 13 personal and 54 area samples. Of the long-term personal samples, airborne concentrations of metals ranged from <0.001 to 2.9mg/m(3), and, in all but one case, resulted in concentrations below the current U.S. Occupational Safety and Health Administration's Permissible Exposure Limits and the American Conference of Governmental Industrial Hygienists' Threshold Limit Values. The arithmetic mean total dust concentration resulting from long-term personal samples was 0.31mg/m(3). The data presented here are the most complete set of its kind in the open literature, and are useful for understanding the potential exposures during solid catalyst handling activities at this petroleum refinery and perhaps other modern refineries during the timeframe examined. PMID:22177528

  10. A coupled model of the airborne and surface concentration of radionuclides considering the resuspension-deposition process

    NASA Astrophysics Data System (ADS)

    Ichige, Hiroyuki; Hatano, Yuko; Onda, Yuichi

    2014-05-01

    We propose a new model of estimating the long-term behavior of both the airborne and the surface concentrations of radionuclides in the vicinity of 30 km of Fukushima plant. Our model consists of the following simultaneous equations: δC- = viδC-+ ΛupS - ΛdownC - ΛdecC (1) δt δxi δS- = - Λ S + Λ C - Λ S, (2) δt up down env where C is the airborne concentration of a specific nuclide, S the surface concentration, the suffix i is 1 or 2 (2 dimensional), v the effective wind velocity which migrates the radionuclides in the air, Λup the rate constant of resuspension process, Λdown of deposition process, Λdec the decay constant, and Λenv is the rate constant of the surface concentration decrease due to environmental factors such as runoff, washoff, infiltrations, and the vegetation effects. These equations are based on our former study (Hatano and Hatano, 1997; Hatano et al., 1998) which successfully reproduce the long-term decrease of airborne concentration of the Chernobyl data such as Cs-137, Cs-134, Ce-144, and Ru-106 over nearly a decade. The first equation of the present study is essentially the same as our previous studies, besides that we added a new term for deposition. The second equation is newly added in the present study which describes the behavior of the surface concentration. In Fukushima case, we found that the radiation risk is much higher than the airborne concentration. That is why we add the second equation. Since the new model requires parameter values of Λs we need to estimate these values from actual data. In order to do so, we apply the method of inverse problem and thereby estimate the values. We also do the spectral analysis of the dose rate (mainly from Cs-137, -134) and study if it is possible to estimate the resuspended amount from the ground surface.

  11. Airborne DOAS measurements in Arctic: vertical distributions of aerosol extinction coefficient and NO2 concentration

    NASA Astrophysics Data System (ADS)

    Merlaud, A.; van Roozendael, M.; Theys, N.; Fayt, C.; Hermans, C.; Quennehen, B.; Schwarzenboeck, A.; Ancellet, G.; Pommier, M.; Pelon, J.; Burkhart, J.; Stohl, A.; de Mazière, M.

    2011-09-01

    We report on airborne Differential Optical Absorption Spectroscopy (DOAS) measurements of aerosol extinction and NO2 tropospheric profiles performed off the North coast of Norway in April 2008. The DOAS instrument was installed on the Safire ATR-42 aircraft during the POLARCAT-France spring campaign and recorded scattered light spectra in near-limb geometry using a scanning telescope. We use O4 slant column measurements to derive the aerosol extinction at 360 nm. Regularization is based on the maximum a posteriori solution, for which we compare a linear and a logarithmic approach. The latter inherently constrains the solution to positive values and yields aerosol extinction profiles more consistent with independently measured size distributions. We present results from two soundings performed on 8 April 2008 above 71° N, 22° E and on 9 April 2008 above 70° N, 17.8° E. The first profile shows aerosol extinction and NO2 in the marine boundary layer with respective values of 0.04 ± 0.005 km-1 and 1.9 ± 0.3 × 109 molec cm-3. A second extinction layer of 0.01 ± 0.003 km-1 is found at 4 km altitude where the NO2 concentration is 0.32 ± 0.2 × 109 molec cm-3. During the second sounding, clouds prevent retrieval of profile parts under 3 km altitude but a layer with enhanced extinction (0.025 ± 0.005 km-1) and NO2 (1.95 ± 0.2 × 109 molec cm-3) is clearly detected at 4 km altitude. From CO and ozone in-situ measurements complemented by back-trajectories, we interpret the measurements in the free troposphere as, for the first sounding, a mix between stratospheric and polluted air from Northern Europe and for the second sounding, polluted air from Central Europe containing NO2. Considering the boundary layer measurements of the first flight, modeled source regions indicate closer sources, especially the Kola Peninsula smelters, which can explain the NO2 enhancement not correlated with a CO increase at the same altitude.

  12. LOAC (Light Optical Particle Counter): a new small aerosol counter with particle characterization capabilities for surface and airborne measurements

    NASA Astrophysics Data System (ADS)

    Renard, Jean-Baptiste; Berthet, Gwenael; Jégou, Fabrice; Jeannot, Matthieu; Jourdain, Line; Dulac, François; Mallet, Marc; Dupont, Jean-Charles; Thaury, Claire; Tonnelier, Thierry; Verdier, Nicolas; Charpentier, Patrick

    2013-04-01

    The determination of the size distribution of tropospheric and stratospheric aerosols with conventional optical counters is difficult when different natures of particles are present (droplets, soot, mineral dust, secondary organic or mineral particles...). Also, a light and cheap aerosol counter that can be used at ground, onboard drones or launched under all kinds of atmospheric balloons can be very useful during specific events as volcanic plumes, desert dust transport or local pollution episodes. These goals can be achieved thanks to a new generation of aerosol counter, called LOAC (Light Optical Aerosol Counter). The instrument was developed in the frame of a cooperation between French scientific laboratories (CNRS), the Environnement-SA and MeteoModem companies and the French Space Agency (CNES). LOAC is a small optical particle counter/sizer of ~250 grams, having a low electrical power consumption. The measurements are conducted at two scattering angles. The first one, at 12°, is used to determine the aerosol particle concentrations in 19 size classes within a diameter range of 0.3-100 micrometerers. At such an angle close to forward scattering, the signal is much more intense and the measurements are the least sensitive to the particle nature. The second angle is at 60°, where the scattered light is strongly dependent on the particle refractive index and thus on the nature of the aerosols. The ratio of the measurements at the two angles is used to discriminate between the different types of particles dominating the nature of the aerosol particles in the different size classes. The sensor particularly discriminates wet or liquid particles, soil dust and soot. Since 2011, we have operated LOAC in various environments (Arctic, Mediterranean, urban and peri-urban…) under different kinds of balloons including zero pressure stratospheric, tethered, drifting tropospheric, and meteorological sounding balloons. For the last case, the total weight of the gondola

  13. High concentrations of biological aerosol particles and ice nuclei during and after rain

    NASA Astrophysics Data System (ADS)

    Huffman, J. A.; Prenni, A. J.; DeMott, P. J.; Pöhlker, C.; Mason, R. H.; Robinson, N. H.; Fröhlich-Nowoisky, J.; Tobo, Y.; Després, V. R.; Garcia, E.; Gochis, D. J.; Harris, E.; Müller-Germann, I.; Ruzene, C.; Schmer, B.; Sinha, B.; Day, D. A.; Andreae, M. O.; Jimenez, J. L.; Gallagher, M.; Kreidenweis, S. M.; Bertram, A. K.; Pöschl, U.

    2013-07-01

    Bioaerosols are relevant for public health and may play an important role in the climate system, but their atmospheric abundance, properties, and sources are not well understood. Here we show that the concentration of airborne biological particles in a North American forest ecosystem increases significantly during rain and that bioparticles are closely correlated with atmospheric ice nuclei (IN). The greatest increase of bioparticles and IN occurred in the size range of 2-6 μm, which is characteristic for bacterial aggregates and fungal spores. By DNA analysis we found high diversities of airborne bacteria and fungi, including groups containing human and plant pathogens (mildew, smut and rust fungi, molds, Enterobacteriaceae, Pseudomonadaceae). In addition to detecting known bacterial and fungal IN (Pseudomonas sp., Fusarium sporotrichioides), we discovered two species of IN-active fungi that were not previously known as biological ice nucleators (Isaria farinosa and Acremonium implicatum). Our findings suggest that atmospheric bioaerosols, IN, and rainfall are more tightly coupled than previously assumed.

  14. Airborne particulate matter in spacecraft

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Acceptability limits and sampling and monitoring strategies for airborne particles in spacecraft were considered. Based on instances of eye and respiratory tract irritation reported by Shuttle flight crews, the following acceptability limits for airborne particles were recommended: for flights of 1 week or less duration (1 mg/cu m for particles less than 10 microns in aerodynamic diameter (AD) plus 1 mg/cu m for particles 10 to 100 microns in AD); and for flights greater than 1 week and up to 6 months in duration (0.2 mg/cu m for particles less than 10 microns in AD plus 0.2 mg/cu m for particles 10 to 100 microns in AD. These numerical limits were recommended to aid in spacecraft atmosphere design which should aim at particulate levels that are a low as reasonably achievable. Sampling of spacecraft atmospheres for particles should include size-fractionated samples of 0 to 10, 10 to 100, and greater than 100 micron particles for mass concentration measurement and elementary chemical analysis by nondestructive analysis techniques. Morphological and chemical analyses of single particles should also be made to aid in identifying airborne particulate sources. Air cleaning systems based on inertial collection principles and fine particle collection devices based on electrostatic precipitation and filtration should be considered for incorporation into spacecraft air circulation systems. It was also recommended that research be carried out in space in the areas of health effects and particle characterization.

  15. Comparative study of airborne viable particles assessment methods in microbiological environmental monitoring.

    PubMed

    Temprano, G; Garrido, D; Daquino, M

    2004-01-01

    A comparative study was done among available assessment methods to measure airborne viable particles in controlled rooms. Active methods were compared (sieve/nozzle impactor, slit-to-agar, centrifugal, filtration, and impinger). The comparative study was carried out by means of a two-way (factors: day and method) analysis of variance, after to logarithmical transformation of experimental results in order to fulfill the normality test of the variables. Statistically significant differences were found among the results of the five methods (P < 0.0001). In a post hoc study, by means of Tukey's test, no differences were found among centrifugal, filtration, and impinger methods. Differences were found among all the other methods (P < 0.05). It is concluded that centrifugal, filtration, and impinger methods (in which numerical results were higher than in the others) may be the most suitable methods for microbiological monitoring of a clean room. The mean results among the three selected active methods were compared with results on the settle plate (SP) (the passive method). A relationship was established between results of the passive method (CFU/h/plate 90 mmø) and the results of active methods (CFU/m3 air). By means of a lineal regression study, it was obtained a relation factor of 22.7; (95% CI: 19.7, 25.7). This factor is only valid for values between 3 and 16 in CFU/h/plate 90 mmø, and it is put on record that the experimental study took place in a room that fulfills Class D clean room specifications (WHO standards) in microbiological terms. PMID:15368991

  16. Rapid identification of airborne biological particles by flow cytometry, gas chromatography, and genetic probes. Final report, January 1995-January 1997

    SciTech Connect

    Wick, C.H.; Carlon, H.R.; Edmonds, R.L.; Robert, L.; Blew, J.

    1997-09-01

    Detection of airborne biological particulates is a primary mission of the U.S. Army Edgewood Research, Development and Engineering Center biological defense program. If biological particles could be characterized according to their unique physical and biochemical profiles, detection and perhaps even identification of the particles might be possible. This study focused upon microbial particles, more specifically upon fungal spores, yeast cells, and bacterial cells. Physical characteristics of the particles, it was proposed, could be detected by flow cytometry, while their biochemical profiles could be determined by gas chromatography, and their genetic identity could be obtained by either a suitable genetic probe or by matching its genetic fingerprint. Genetic techniques were not attempted in the work reported here, but the approach was investigated further. Trial results were encouraging.

  17. Measurement of Soluble and Total Hexavalent Chromium in the Ambient Airborne Particles in New Jersey

    PubMed Central

    Huang, Lihui; Yu, Chang Ho; Hopke, Philip K.; Lioy, Paul J.; Buckley, Brian T.; Shin, Jin Young; Fan, Zhihua (Tina)

    2015-01-01

    Hexavalent chromium (Cr(VI)) in ambient airborne particulate matter (PM) is a known pulmonary carcinogen and may have both soluble and insoluble forms. The sum of the two forms is defined as total Cr(VI). Currently, there were no methods suitable for large-scale monitoring of total Cr(VI) in ambient PM. This study developed a method to measure total Cr(VI) in ambient PM. This method includes PM collection using a Teflon filter, microwave extraction with 3% Na2CO3-2% NaOH at 95°C for 60 minutes, and Cr(VI) analysis by 1,5-diphenylcarbazide colorimetry at 540 nm. The recoveries of total Cr(VI) were 119.5 ± 10.4% and 106.3 ± 16.7% for the Cr(VI)-certified reference materials, SQC 012 and SRM 2700, respectively. Total Cr(VI) in the reference urban PM (NIST 1648a) was 26.0 ± 3.1 mg/kg (%CV = 11.9%) determined by this method. The method detection limit was 0.33 ng/m3. This method and the one previously developed to measure ambient Cr(VI), which is soluble in pH ~9.0 aqueous solution, were applied to measure Cr(VI) in ambient PM10 collected from three urban areas and one suburban area in New Jersey. The total Cr(VI) concentrations were 1.05–1.41 ng/m3 in the winter and 0.99–1.56 ng/m3 in the summer. The soluble Cr(VI) concentrations were 0.03–0.19 ng/m3 in the winter and 0.12–0.37 ng/m3 in the summer. The summer mean ratios of soluble to total Cr(VI) were 14.3–43.7%, significantly higher than 4.2–14.4% in the winter. The winter concentrations of soluble and total Cr(VI) in the suburban area were significantly lower than in the three urban areas. The results suggested that formation of Cr(VI) via atmospheric chemistry may contribute to the higher soluble Cr(VI) concentrations in the summer. PMID:26120324

  18. Airborne exposures to PAH and PM2.5 particles for road paving workers applying conventional asphalt and crumb rubber modified asphalt.

    PubMed

    Watts, R R; Wallingford, K M; Williams, R W; House, D E; Lewtas, J

    1998-01-01

    Personal exposure monitoring was conducted for road paving workers in three states. A research objective was to characterize and compare occupational exposures to fine respirable particles (< 2.5 microns) and particle-bound polycyclic aromatic hydrocarbons (PAHs) for road paving workers applying conventional (petroleum derived) asphalt and asphalt containing crumb rubber from shredded tires. Workers not exposed to asphalt fume were also included for comparison (to support the biomarker component of this study). The rubber content of the crumb rubber modified (CRM) asphalt at the three study sites was 12, 15, and 20%. A comparison of some specific job categories from two sites indicates greater potential carcinogenic PAH exposures during CRM asphalt work, however, the site with the greatest overall exposures did not indicate any differences for specific jobs. A statistical analysis of means for fine particle, pyrene and total carcinogenic PAH personal exposure shows, with two exceptions, there were no differences in exposures for these three measurement variables. One site shows significantly elevated pyrene exposure for CRM asphalt workers and another site similarly shows greater carcinogenic PAH exposure for CRM asphalt workers. Conventional and CRM asphalt worker airborne exposures to the PAH carcinogen marker, BaP, were very low with concentrations comparable to ambient air in many cities. However, this study demonstrates that asphalt road paving workers are exposed to elevated airborne concentrations of a group of unknown compounds that likely consist of the carcinogenic PAHs benz(a)anthracene, chrysene and methylated derivatives of both. The research described in this article has been reviewed in accordance with U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. PMID:9577752

  19. The white-light humidified optical particle spectrometer (WHOPS) - a novel airborne system to characterize aerosol hygroscopicity

    NASA Astrophysics Data System (ADS)

    Rosati, B.; Wehrle, G.; Gysel, M.; Zieger, P.; Baltensperger, U.; Weingartner, E.

    2015-02-01

    Aerosol particles experience hygroscopic growth at enhanced relative humidity (RH), which leads to changes in their optical properties. We developed the white-light humidified optical particle spectrometer (WHOPS), a new instrument to investigate the particles' hygroscopic growth. Here we present a detailed technical description and characterization of the WHOPS in laboratory and field experiments. The WHOPS consists of a differential mobility analyzer, a humidifier/bypass and a white-light aerosol spectrometer (WELAS) connected in series to provide fast measurements of particle hygroscopicity at subsaturated RH and optical properties on airborne platforms. The WELAS employs a white-light source to minimize ambiguities in the optical particle sizing. In contrast to other hygroscopicity instruments, the WHOPS retrieves information of relatively large particles (i.e., diameter D > 280 nm), therefore investigating the more optically relevant size ranges. The effective index of refraction of the dry particles is retrieved from the optical diameter measured for size-selected aerosol samples with a well-defined dry mobility diameter. The data analysis approach for the optical sizing and retrieval of the index of refraction was extensively tested in laboratory experiments with polystyrene latex size standards and ammonium sulfate particles of different diameters. The hygroscopic growth factor (GF) distribution and aerosol mixing state is inferred from the optical size distribution measured for the size-selected and humidified aerosol sample. Laboratory experiments with pure ammonium sulfate particles revealed good agreement with Köhler theory (mean bias of ~3% and maximal deviation of 8% for GFs at RH = 95%). During first airborne measurements in the Netherlands, GFs (mean value of the GF distribution) at RH = 95% between 1.79 and 2.43 with a median of 2.02 were observed for particles with a dry diameter of 500 nm. This corresponds to hygroscopicity parameters (κ

  20. Effects of ceiling-mounted HEPA-UV air filters on airborne bacteria concentrations in an indoor therapy pool building.

    PubMed

    Kujundzic, Elmira; Zander, David A; Hernandez, Mark; Angenent, Largus T; Henderson, David E; Miller, Shelly L

    2005-02-01

    The purpose of this study was to assess the effectiveness of a new generation of high-volume, ceiling-mounted high-efficiency particulate air (HEPA)-ultraviolet (UV) air filters (HUVAFs) for their ability to remove or inactivate bacterial aerosol. In an environmentally controlled full-scale laboratory chamber (87 m3), and an indoor therapy pool building, the mitigation ability of air filters was assessed by comparing concentrations of total bacteria, culturable bacteria, and airborne endotoxin with and without the air filters operating under otherwise similar conditions. Controlled chamber tests with pure cultures of aerosolized Mycobacterium parafortuitum cells showed that the HUVAF unit tested provided an equivalent air-exchange rate of 11 hr(-1). Using this equivalent air-exchange rate as a design basis, three HUVAFs were installed in an indoor therapy pool building for bioaerosol mitigation, and their effectiveness was studied over a 2-year period. The HUVAFs reduced concentrations of culturable bacteria by 69 and 80% during monitoring periods executed in respective years. The HUVAFs reduced concentrations of total bacteria by 12 and 76% during the same monitoring period, respectively. Airborne endotoxin concentrations were not affected by the HUVAF operation. PMID:15796111

  1. Airborne and groundbased measurements of ash particles on Iceland and over Germany during the Grímsvötn eruption May 2011

    NASA Astrophysics Data System (ADS)

    Vogel, A.; Weber, K.; Eliasson, J.; Palsson, A.; Moser, H. M.; Palsson, T.; von Löwis, S.; Fischer, C.

    2012-04-01

    The eruption of the Grimsvötn volcano in May 2010 posed with its ash plume a thread to the aviation in northern Europe. Because of ash plume forecasts of the VAAC London the airport of Keflavik in Iceland as well as airports in England, Scotland and Scandinavia were closed for some time, which caused the cancellation or change of about 500 flights in Europe. Even in Germany the airports of Bremen, Hamburg and Berlin were closed for several hours on 25 May 2011. During this eruption period in May 2011, a team of the Duesseldorf University of Applied Sciences, the University of Iceland, the University of Reykjavik and the IMO has performed airborne in-situ measurements over Iceland and Germany as well as ground based measurements in the south of Iceland. The ground based measurements were performed continuously during the whole eruption period at two significant positions (Skogar and Hvollsvöllur) with optical particle counters (OPCs). The measurement method was based on measuring the airborne concentrations of the classic aerosol components (PM10, PM2.5 and PM1) and TSP (total suspended particles) every 6 seconds. Additional measurement flights on Iceland were started already one day after the beginning of the eruption (twelve in-situ measurement flights) and marked the spatial and temporal spread of volcanic ash in the atmosphere. For the flights light slow flying piston engine powered airplanes where used. The flights over Iceland focused on the western part of Iceland in the region of Reykjavik and Keflavik and over the international airport in Keflavik and were mostly coordinated by ISAVIA. The measurement flights helped to keep Keflavik International Airport open for many additional hours despite of adverse predictions by the London VAAC model, because it was possible to observe the particle concentration on-line during the flights. In Germany a measurement flight was performed on 25 May 2012 over the northern part of Germany where the volcanic ash cloud was

  2. PARTICLE ASSOCIATION EFFECTS ON MICROBIAL INDICATOR CONCENTRATIONS FOR CSO DISINFECTION

    EPA Science Inventory

    The effect of blending on indicator microorganism concentrations in combined sewer overflow (CSO) was investigated due to concerns that standard techniques fail to measure particle-associated organisms found in sewage. It was shown that blending CSO samples diluted in a mixture ...

  3. Acoustic Measurement of Suspended Fine Particle Concentrations by Attenuation

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Knowledge of sediment concentration is important in the study of streams and rivers. The work presented explores the appropriate frequency and transducer spacing for acoustic measurement of suspended particles in the range of 0.1 – 64 microns. High frequency (20 MHz) acoustic signal attenuation wa...

  4. Measurements of polycyclic aromatic hydrocarbons in airborne particles from the metropolitan area of São Paulo City, Brazil

    NASA Astrophysics Data System (ADS)

    Vasconcellos, Pérola C.; Zacarias, Davi; Pires, Maria A. F.; Pool, Cristina S.; Carvalho, Lilian R. F.

    Polycyclic aromatic hydrocarbons (PAHs) from phenanthrene to benzo[g,h,i]perylene in airborne particles were measured in the winter of 2000 at three different sites within the metropolitan area of São Paulo City (MASP), Brazil. It is one of the largest metropolitan areas in the world and has an unconventional mixture of vehicle types, in which a variety of gasoline blends, including oxygenated ones, are used. In this study, occurrence of PAH, meteorological conditions and inter and intrasite comparisons are presented. Overall, the results revealed low PAH levels due to rainfall episodes during the sampling period. Samples collected in the urban site presented the highest PAH concentrations (av. 3.10 ng m -3) when compared to those collected in the urban site with dense vegetation (av. 2.73 ng m -3) and in the forest area (av. 1.92 ng m -3). PAH measurements in tunnels with different types of vehicles were performed in order to suggest possible tracers of the vehicular emissions in São Paulo. Pyrene followed by chrysene and fluoranthene were emitted mainly from gasohol vehicular motor exhausts, whereas chrysene, pyrene and benzo[a]anthracene were emitted mainly from gasohol and diesel vehicular motor exhausts. Some characteristic ratios from the tunnel measurements were used to identify vehicular sources in the atmosphere of the MASP. Although it is known that losses can occur both by evaporation and sublimation during sampling, measurements of higher molecular weight PAH compounds were taken into consideration due to their high recovery efficiency.

  5. Resolving Organized Aerosol Structures (Rolls and Layers) with Airborne Fast Mobility Particle Sizer (FMPS) During MILAGRO/INTEX Campaign

    NASA Astrophysics Data System (ADS)

    Kapustin, V.; Clarke, A.; Zhou, J.; Howell, S.; Shinozuka, Y.; Brekhovskikh, V.; McNaughton, C.

    2007-12-01

    The Hawaii Group for Environmental Aerosol Research [http://www.soest.hawaii.edu/HIGEAR] deployed a wide range of aerosol instrumentation aboard the C-130 and the NASA DC-8 as part of MILAGRO/INTEX. These were designed to provide rapid information on aerosol composition, state of mixing (internal or external), spectral optical properties (scattering and absorption), the humidity dependence of light scattering-f(RH), and the role of condensed species in changing the absorption properties of black carbon (BC) and inferred properties of organic carbon (OC). These measurements included size distributions from about 7 nm up to about 10,000 nm and their volatility at 150, 300 and 400 C; size selected response to heating (volatility) to resolve the state of mixing of the aerosol; continuous measurements of the light scattering and absorption at 3 wavelengths; measurements of the f(RH). We also flew the first airborne deployment of the new Fast Mobility Particle Sizer (FMPS, TSI Inc.) that provided information on rapid (1Hz) size variations in the Aitken mode. This revealed small scale structure of the aerosol and allowed us to examine size distributions varying over space and time associated with mixing processes previously unresolved etc. Rapid measurements during profiles also revealed variations in size over shallow layers. Other dynamic processes included rapid size distribution measurements within orographically induced aerosol layers and size distribution evolution of the nanoparticles formed by nucleation (C-130 flights 5, 6 and 9). Evidence for fluctuations induced by underlying changes in topography was also detected. These measurements also frequently revealed the aerosol variability in the presence of boundary layer rolls aligned along the wind in the Marine Boundary Layer (Gulf region) both with and without visible cloud streets (DC-8 flight 4 and C-130 flight 7). This organized convection over 1-2 km scales influences the mixing processes (entrainment, RH

  6. Modeling the effect of outdoor particle concentrations on indoor concentrations in a heated environment

    SciTech Connect

    Pandian, M.D. )

    1988-01-01

    Exposure to suspended particulate mater in the home or workplace can produce adverse human health effects. Sources of suspended particulate matter include cigarette smoke, consumer spray products, and dust from cement manufacture, metal processing, and coal-fired power generation. The particle concentrations in these indoor environments can be determined from experimental studies or modeling techniques. Many experimental studies have been conducted to determine the mass concentration of total suspended particulate matter, usually expressed in {mu}g/m{sup 3}, and the elemental composition of particulate matter in these environments. However, there is not much reported data on particle size distributions in indoor environments. One of the early indoor modeling efforts was undertaken by Shair and Heitner, who conducted a theoretical analysis for relating indoor pollutant concentrations to those outdoors. The author describes the theoretical analysis and compared it to results obtained from experiments on conditioned cigarette smoke particle concentrations in a room at 20{degrees}C and 60 {percent}.

  7. Nanoscale characterization of PM2.5 airborne pollutants reveals high adhesiveness and aggregation capability of soot particles

    PubMed Central

    Shi, Yuanyuan; Ji, Yanfeng; Sun, Hui; Hui, Fei; Hu, Jianchen; Wu, Yaxi; Fang, Jianlong; Lin, Hao; Wang, Jianxiang; Duan, Huiling; Lanza, Mario

    2015-01-01

    In 2012 air pollutants were responsible of seven million human death worldwide, and among them particulate matter with an aerodynamic diameter of 2.5 micrometers or less (PM2.5) are the most hazardous because they are small enough to invade even the smallest airways and penetrate to the lungs. During the last decade the size, shape, composition, sources and effect of these particles on human health have been studied. However, the noxiousness of these particles not only relies on their chemical toxicity, but particle morphology and mechanical properties affect their thermodynamic behavior, which has notable impact on their biological activity. Therefore, correlating the physical, mechanical and chemical properties of PM2.5 airborne pollutants should be the first step to characterize their interaction with other bodies but, unfortunately, such analysis has never been reported before. In this work, we present the first nanomechanical characterization of the most abundant and universal groups of PM2.5 airborne pollutants and, by means of atomic force microscope (AFM) combined with other characterization tools, we observe that fluffy soot aggregates are the most sticky and unstable. Our experiments demonstrate that such particles show strong adhesiveness and aggregation, leading to a more diverse composition and compiling all possible toxic chemicals. PMID:26177695

  8. Nanoscale characterization of PM2.5 airborne pollutants reveals high adhesiveness and aggregation capability of soot particles.

    PubMed

    Shi, Yuanyuan; Ji, Yanfeng; Sun, Hui; Hui, Fei; Hu, Jianchen; Wu, Yaxi; Fang, Jianlong; Lin, Hao; Wang, Jianxiang; Duan, Huiling; Lanza, Mario

    2015-01-01

    In 2012 air pollutants were responsible of seven million human death worldwide, and among them particulate matter with an aerodynamic diameter of 2.5 micrometers or less (PM2.5) are the most hazardous because they are small enough to invade even the smallest airways and penetrate to the lungs. During the last decade the size, shape, composition, sources and effect of these particles on human health have been studied. However, the noxiousness of these particles not only relies on their chemical toxicity, but particle morphology and mechanical properties affect their thermodynamic behavior, which has notable impact on their biological activity. Therefore, correlating the physical, mechanical and chemical properties of PM2.5 airborne pollutants should be the first step to characterize their interaction with other bodies but, unfortunately, such analysis has never been reported before. In this work, we present the first nanomechanical characterization of the most abundant and universal groups of PM2.5 airborne pollutants and, by means of atomic force microscope (AFM) combined with other characterization tools, we observe that fluffy soot aggregates are the most sticky and unstable. Our experiments demonstrate that such particles show strong adhesiveness and aggregation, leading to a more diverse composition and compiling all possible toxic chemicals. PMID:26177695

  9. Nanoscale characterization of PM2.5 airborne pollutants reveals high adhesiveness and aggregation capability of soot particles

    NASA Astrophysics Data System (ADS)

    Shi, Yuanyuan; Ji, Yanfeng; Sun, Hui; Hui, Fei; Hu, Jianchen; Wu, Yaxi; Fang, Jianlong; Lin, Hao; Wang, Jianxiang; Duan, Huiling; Lanza, Mario

    2015-07-01

    In 2012 air pollutants were responsible of seven million human death worldwide, and among them particulate matter with an aerodynamic diameter of 2.5 micrometers or less (PM2.5) are the most hazardous because they are small enough to invade even the smallest airways and penetrate to the lungs. During the last decade the size, shape, composition, sources and effect of these particles on human health have been studied. However, the noxiousness of these particles not only relies on their chemical toxicity, but particle morphology and mechanical properties affect their thermodynamic behavior, which has notable impact on their biological activity. Therefore, correlating the physical, mechanical and chemical properties of PM2.5 airborne pollutants should be the first step to characterize their interaction with other bodies but, unfortunately, such analysis has never been reported before. In this work, we present the first nanomechanical characterization of the most abundant and universal groups of PM2.5 airborne pollutants and, by means of atomic force microscope (AFM) combined with other characterization tools, we observe that fluffy soot aggregates are the most sticky and unstable. Our experiments demonstrate that such particles show strong adhesiveness and aggregation, leading to a more diverse composition and compiling all possible toxic chemicals.

  10. System for concentrating and analyzing particles suspended in a fluid

    DOEpatents

    Fiechtner, Gregory J.; Cummings, Eric B.; Singh, Anup K.

    2011-04-26

    Disclosed is a device for separating and concentrating particles suspended in a fluid stream by using dielectrophoresis (DEP) to trap and/or deflect those particles as they migrate through a fluid channel. The method uses fluid channels designed to constrain a liquid flowing through it to uniform electrokinetic flow velocities. This behavior is achieved by connecting deep and shallow sections of channels, with the channel depth varying abruptly along an interface. By careful design of abrupt changes in specific permeability at the interface, an abrupt and spatially uniform change in electrokinetic force can be selected. Because these abrupt interfaces also cause a sharp gradient in applied electric fields, a DEP force also can be established along the interface. Depending on the complex conductivity of the suspended particles and the immersion liquid, the DEP force can controllably complement or oppose the local electrokinetic force transporting the fluid through the channel allowing for manipulation of particles suspended in the transporting liquid.

  11. Determination of Solid Particle Concentration at coal Transshipment site

    NASA Astrophysics Data System (ADS)

    Siliņš, K.; Žandeckis, A.; Valtere, S.

    2009-01-01

    Coal handling and grinding processes are associated with significant particulate matter emissions into the atmosphere. This problem is particularly urgent when a coal-processing company is located in or nearby a densely populated city. To quantitatively evaluate concentrations generated into the atmosphere according to the standardized methodology, it is necessary to make extensive measurements using an automatic real-time, infrared dust and aerosol monitor. Before the experiments, the impact of particulate matter on human health and the environment was explored, six solid particle concentration detection methods and best available techniques for particulate matter emission prevention was described. During this study field measurements were carried out at on the territory of a coal transshipment company. Using the solid particle concentration detection system Dust Detective kit, concentration monitoring of total particulate matter (TSP), PM10 and PM2.5 was carried out. The equipment was located 6 m above ground and 120 m away from the emission source - coal crushing and handling site. TSP monitoring was carried out during four diurnal, PM10 - during 17 diunral and PM2.5 - during 12 days. After comparison of results with concentration values set in normative documents of Latvia and EU, it was found out that average 17 diurnal day concentration values of PM10 exceeded normative values for nine times. PM2.5 daily average concentrations of 12 days exceeded for four times exceeded the value of 25 μg/m3, which is mentioned in Directive 2008/50/EC of EU. After analysis of wind behaviour impact on the concentration values it is now understood that if wind comes from the dust emission source to the measurement system, the increase in wind speed increases particle concentration as all particles in the air and those raised from coal piles are driven towards the equipment. If wind comes from the opposite direction, the decrease of wind velocity results in an increase of

  12. Mutagenicity and polycyclic aromatic hydrocarbons associated with extractable organic matter from airborne particles ⩽10 μm in southwest Mexico City

    NASA Astrophysics Data System (ADS)

    Villalobos-Pietrini, Rafael; Amador-Muñoz, Omar; Waliszewski, Stefan; Hernández-Mena, Leonel; Munive-Colín, Zenaida; Gómez-Arroyo, Sandra; Bravo-Cabrera, José Luis; Frías-Villegas, Alejandro

    A year-long sampling and analysis of 24 h airborne particles equal to or less than 10 μm (PM 10) was conducted in Southwest (SW) Mexico City in 1998. The amount of airborne PM 10 and its extractable organic matter (EOM) were highly correlated. The year 1998 was particularly dry with many fires, and higher values of PM 10 and EOM were obtained in the fire period (February-May) compared to the without fire period (January, June-December). The indirect-acting mutagenicity ( Salmonella typhimurium strain TA98 with mammalian metabolic activation, S9) did not correlate with the monthly concentrations of PM 10 and EOM, while the direct-acting mutagenicity (strains TA98 and YG1021, without mammalian metabolic activation) did correlate. The highest monthly mutagenic potency of TA98+S9 and of TA98-S9 were registered in May which correspond to the fire period, while for YG1021 the highest was in December, a without fire month. The highest TA98+S9/TA98-S9 ratios appeared from April to September (with the exception of June), indicating that emission of the direct mutagens occurred in the rest of the year (the coldest months), and December showed the highest mutagenicity of YG1021. The correlation of this mutagenicity with the number of ground-based inversions indicated a greater emissions of nitroarenes in the coldest months emitted mainly by vehicular traffic as shown by the correlation between YG1021 with CO and with NO 2. We did not find a correlation in the EOM of the complex mixtures between TA98+S9 and the total concentration of polycyclic aromatic hydrocarbons (PAH) nor between TA98+S9 and specific PAH. The analysis by gas chromatography/mass spectrometry indicated the presence of retene, a PAH found in the fire period and considered a softwood burning marker. The concentrations of fluoranthene and benz[ a]anthracene correlated with that of retene and with the burned area; they were the only PAH that presented significant differences between the periods with fire and

  13. Chemical speciation of size-segregated floor dusts and airborne magnetic particles collected at underground subway stations in Seoul, Korea.

    PubMed

    Jung, Hae-Jin; Kim, BoWha; Malek, Md Abdul; Koo, Yong Sung; Jung, Jong Hoon; Son, Youn-Suk; Kim, Jo-Chun; Kim, HyeKyoung; Ro, Chul-Un

    2012-04-30

    Previous studies have reported the major chemical species of underground subway particles to be Fe-containing species that are generated from wear and friction processes at rail-wheel-brake and catenaries-pantographs interfaces. To examine chemical composition of Fe-containing particles in more details, floor dusts were collected at five sampling locations of an underground subway station. Size-segregated floor dusts were separated into magnetic and non-magnetic fractions using a permanent magnet. Using X-ray diffraction (XRD) and scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDX), iron metal, which is relatively harmless, was found to be the dominating chemical species in the floor dusts of the <25 μm size fractions with minor fractions of Mg, Al, Si, Ca, S, and C. From SEM analysis, the floor dusts of the <25 μm size fractions collected on railroad ties appeared to be smaller than 10 μm, indicating that their characteristics should somewhat reflect the characteristics of airborne particles in the tunnel and the platform. As most floor dusts are magnetic, PM levels at underground subway stations can be controlled by removing magnetic indoor particles using magnets. In addition, airborne subway particles, most of which were smaller than 10 μm, were collected using permanent magnets at two underground subway stations, namely Jegi and Yangjae stations, in Seoul, Korea. XRD and SEM/EDX analyses showed that most of the magnetic aerosol particles collected at Jegi station was iron metal, whereas those at Yangjae station contained a small amount of Fe mixed with Na, Mg, Al, Si, S, Ca, and C. The difference in composition of the Fe-containing particles between the two subway stations was attributed to the different ballast tracks used. PMID:22381374

  14. Commuting-Adjusted Short-Term Health Impact Assessment of Airborne Fine Particles with Uncertainty Quantification via Monte Carlo Simulation

    PubMed Central

    Grisotto, Laura; Catelan, Dolores; Consonni, Dario; Bertazzi, Pier Alberto; Biggeri, Annibale

    2014-01-01

    Background: Exposure to air pollution is associated with a short-term increase in mortality, and this field has begun to focus on health impact assessment. Objectives: Our aim was to estimate the impact of PM10 on mortality within 2 days from the exposure in the Italian region of Lombardy for the year 2007, at the municipality level, examining exposure entailed by daily intermunicipality commuting and accounting for uncertainty propagation. Methods: We combined data from different sources to derive probabilistic distributions for all input quantities used to calculate attributable deaths (mortality rates, PM10 concentrations, estimated PM10 effects, and commuting flows) and applied a Monte Carlo procedure to propagate uncertainty and sample the distribution of attributable deaths for each municipality. Results: We estimated that annual average PM10 concentrations above the World Health Organization-recommended threshold of 20 μg/m3 were responsible for 865 short-term deaths (80% credibility interval: 475, 1,401), 26% of which were attributable to PM10 above the European Union limit of 40 μg/m3. Reducing annual average PM10 concentrations > 20 μg/m3 by 20% would have reduced the number of attributable deaths by 36%. The largest estimated impacts were along the basin of the Po River and in the largest cities. Commuting contributed to the spatial distribution of the estimated impact. Conclusions: Our estimates, which incorporated uncertainty quantification, indicate that the short-term impact of PM10 on mortality in Lombardy in 2007 was notable, and that reduction in air pollution would have had a substantial beneficial effect on population health. Using commuting data helped to identify critical areas for prioritizing intervention. Citation: Baccini M, Grisotto L, Catelan D, Consonni D, Bertazzi PA, Biggeri A. 2015. Commuting-adjusted short-term health impact assessment of airborne fine particles with uncertainty quantification via Monte Carlo simulation. Environ

  15. Coulombic wall slip of concentrated soft-particle suspensions

    NASA Astrophysics Data System (ADS)

    Adams, Michael; Liu, Wei; Zhang, Zhibing; Fryer, Peter

    2013-06-01

    The coefficients of friction of concentrated soft-particle suspensions (tomato paste and a microgel suspension) were measured as a function of the slip velocity for a number of substrates. The data are interpreted using a micro-elastohydrodynamic model that is consistent with significant bulk frictional dissipation and an increase in the number of particle-wall contacts with increasing normal stress. The origin of the Coulombic slip, which has not been observed previously for pastes, is ascribed to the sensitivity of the lubricating film thickness.

  16. Genesis Concentrator Target Particle Contamination Mapping and Material Identification

    NASA Technical Reports Server (NTRS)

    Calaway, Michael J.; Rodriquez, M. C.; Allton, J. H.

    2007-01-01

    The majority of surface particles were found to be < 5 microns in diameter with increasing numbers close to the optical resolution limit of 0.3 microns. Acceleration grid EDS results show that the majority of materials appear to be from the SRC shell and SLA materials which include carbon-carbon fibers and Si-rich microspheres in a possible silicone binder. Other major debris material from the SRC included white paint, kapton, collector array fragments, and Al. Image analysis also revealed that SRC materials were also found mixed with the Utah mud and salt deposits. The EDS analysis of the acceleration grid showed that particles < 1 m where generally carbon based particles. Chemical cleaning techniques with Xylene and HF in an ultrasonic bath are currently being investigated for removal of small particles by the Genesis science team as well as ultra-pure water megasonic cleaning by the JSC team [4]. Removal of organic contamination from target materials is also being investigated by the science team with the use of UV-ozone cleaning devices at JSC and Open University [5]. In preparation for solar wind oxygen analyses at UCLA and Open University [1, 2], surface particle contamination on three Genesis concentrator targets was closely examined to evaluate cleaning strategies. Two silicon carbide (Genesis sample # 60001 and 60003) and one chemical vapor deposited (CVD) 13C concentrator target (60002) were imaged and mosaic mapped with optical microscopes. The resulting full target mosaic images and particle feature maps were subsequently compared with non-flight, but flight-like, concentrator targets and sample return capsule (SRC) materials. Contamination found on the flown concentrator acceleration grid was further examined using a scanning electron microscope (SEM). Energy dispersive X-ray spectroscopy (EDS) for particle identification was subsequently compared with the optical images from the flown targets. Figure 1 show that all three targets imaged in this report

  17. Indoor-outdoor relationships of airborne particles and nitrogen dioxide inside Parisian buses

    NASA Astrophysics Data System (ADS)

    Molle, Romain; Mazoué, Sophie; Géhin, Évelyne; Ionescu, Anda

    2013-04-01

    This study evaluated passengers' exposure to traffic air pollution inside the articulated buses of the line 91 in Paris during 10 working days in May, 2010. Twenty articulated buses were studied on 32 routes in order to determine the influence of the sampling position on the pollutant concentrations. This parameter is still poorly known for the rigid buses and is even less known for the articulated ones. However this parameter must be studied for articulated buses because the greater length may cause a pollutant concentration gradient in the cabin. Portable devices were used to measure pollutants in the presence of passengers from 8 a.m. to 9 a.m. and from 4 p.m. to 5 p.m., time periods corresponding to the peak traffic and travellers. PM2.5 mass concentration, particle number concentration between 0.3 and 20 μm and nitrogen dioxide concentration were simultaneously measured on three positions inside the buses (front, middle and rear) in order to study the spatial distribution of these compounds. These measurements inside the buses were compared to the outdoor concentrations at the same moment of the day provided by the Parisian air quality monitoring network; they were also compared to the results of a previous monitoring campaign performed in 2008. The results obtained during the 2010 campaign revealed that in-cabin NO2 mean concentrations were 1.5-3.5 times higher than the outside concentration levels; a maximum concentration of 234 ± 40 μg m-3 was found in the rear position (location of the engine and exhaust gas). Mean in-cabin PM2.5 mass concentrations varied from one week to another one, but they were globally the same at the three positions inside the instrumented buses. In order to determine the impact of outdoor levels, correlations have been calculated between the results measured inside the buses and those measured by the outdoor air monitoring stations. The highest Pearson correlation coefficient was 0.29 for NO2 data whereas the highest Pearson

  18. Automated classification of single airborne particles from two-dimension, angle-resolved optical scattering (TAOS) patterns

    NASA Astrophysics Data System (ADS)

    Crosta, Giovanni F.; Pan, Yong-Le; Chang, Richard K.

    2011-06-01

    Two-dimension, angle-resolved optical scattering (TAOS) is an experimental technique by which patterns of LASER light intensity scattered by single (micrometer or sub-micrometer sized) airborne particles are collected. In the past 10 years TAOS instrumentation has evolved from laboratory prototypes to field-deployable equipment; patterns are collected by the thousands during indoor or outdoor sampling in short times. Although comparison between experimental and computed scattering patterns has been carried out extensively, there is no satisfactory way to relate a given pattern to the particle it comes from. This paper reports about the ongoing development and implementation of a method which is aimed at classifying patterns, rather than identifying original particles. A machine learning algorithm includes the extraction of morphological features and their multivariate statistical analysis. A classifier is trained and validated in a supervised mode, by relying on patterns from known materials. Then the tuned classifier is applied to the recognition of patterns of unknown origin.

  19. LOREP 1993 summary report: Airborne measurements of meteorological variables, atmospheric particles and sulfur hexafluoride. Technical memo

    SciTech Connect

    Wilkison, S.W.; Wellman, D.L.

    1996-03-01

    Meteorological variables and sulfur hexafluoride (SF6) were measured using the NOAA King Air research aircraft during February and March, 1993, over the Sierra Nevada Range of northern California as part of the Lake Oroville Runoff Enhancement Prototype Program (LOREP 1993). Race track pattern flights were made from approximately Sierraville, CA, to Gasner, CA. Airborne sampling was used to locate a plume containing sulfur hexafluoride as a tracer and propane as a seeding agent. The aircraft also carried an optical imaging probe. This report introduces the program in general, discusses the objectives of LOREP 1993, the instrumentation used and the data obtained by the NOAA airborne operation.

  20. Characterization of Fine Airborne Particulate Collected in Tokyo and Major Atmospheric Emission Sources by Using Single Particle Measurement of SEM-EDX

    NASA Astrophysics Data System (ADS)

    Sato, K.; Iijima, A.; Furuta, N.

    2008-12-01

    In our long-term monitoring of size-classified Airborne Particulate Matter (APM) in Tokyo since 1995, it had been demonstrated that toxic elements such as As, Se, Cd, Sb and Pb were extremely enriched in fine APM (PM2.5). However, in that study, total sampled APM on a filter was digested with acids, and thus only averaged elemental composition in fine APM could be obtained. One of the effective methods to determine the origin of APM is single particle measurement by using SEM-EDX. By using characteristic shapes observed by SEM and marker elements contained in APM measured by EDX, detailed information for source identification can be obtained. In this study, fine APM (PM2.5) was collected at various locations such as roadside, diesel vehicle exhaust, a heavy oil combustion plant and a waste incineration plant as well as ambient atmosphere in Tokyo, and characteristics of fine particles that will be utilized for identification of emission sources are elucidated. Fine particles can be classified into 3 main characteristic shape groups; edge-shaped, cotton-like and spherical. Shape of particles collected in a heavy oil combustion plant and a waste incineration plant was mostly spherical, and these particles may be associated with thermal process. Diesel exhaust particles were predominantly cotton-like which may consist of coagulated nano-sized particles. Most of brake abrasion dusts were edge-shaped, which may be associated with mechanical abrasion of brake pads. In the elemental analysis of fine particles, high concentrations of Sb, Cu, Ti and Ba were detected in brake abrasion dusts. Since these elements are major constituents of brake pads, these can be used for marker elements of brake abrasion dusts. High concentration of C was detected in diesel exhaust particles and oil combustion particles, and thus C can be used for marker elements of their origin. Furthermore, high concentrations of C, Ca and K were detected in fly ash from a waste incineration plant, which

  1. PHIPS-HALO: the airborne Particle Habit Imaging and Polar Scattering probe - Part 1: Design and operation

    NASA Astrophysics Data System (ADS)

    Abdelmonem, Ahmed; Järvinen, Emma; Duft, Denis; Hirst, Edwin; Vogt, Steffen; Leisner, Thomas; Schnaiter, Martin

    2016-07-01

    The number and shape of ice crystals present in mixed-phase and ice clouds influence the radiation properties, precipitation occurrence and lifetime of these clouds. Since clouds play a major role in the climate system, influencing the energy budget by scattering sunlight and absorbing heat radiation from the earth, it is necessary to investigate the optical and microphysical properties of cloud particles particularly in situ. The relationship between the microphysics and the single scattering properties of cloud particles is usually obtained by modelling the optical scattering properties from in situ measurements of ice crystal size distributions. The measured size distribution and the assumed particle shape might be erroneous in case of non-spherical ice particles. There is a demand to obtain both information correspondently and simultaneously for individual cloud particles in their natural environment. For evaluating the average scattering phase function as a function of ice particle habit and crystal complexity, in situ measurements are required. To this end we have developed a novel airborne optical sensor (PHIPS-HALO) to measure the optical properties and the corresponding microphysical parameters of individual cloud particles simultaneously. PHIPS-HALO has been tested in the AIDA cloud simulation chamber and deployed in mountain stations as well as research aircraft (HALO and Polar 6). It is a successive version of the laboratory prototype instrument PHIPS-AIDA. In this paper we present the detailed design of PHIPS-HALO, including the detection mechanism, optical design, mechanical construction and aerodynamic characterization.

  2. Computation of Concentric Shell Particle Scattering Effects in Jovian Clouds

    NASA Astrophysics Data System (ADS)

    Fry, Patrick M.; Sromovsky, Lawrence A.

    2014-11-01

    From analysis of NIMS and ISO spectra of Jupiter Sromovsky and Fry (2010, Icarus 210, 211-229; 2010, Icarus 210, 230-257) concluded that both NH3 and NH4SH were present near the visible cloud tops, probably in the form of composite particles. Composite particles were also suggested from analysis of VIMS spectra of Saturn's Great Storm of 2010-2011 by Sromovsky et al. (2013, Icarus 226, 402-418), in this case concentric shells of H2O, NH4SH, and NH3. These results and suggestions that coatings of various materials might be capable of hiding NH3 spectral features on Jupiter, such as by Atreya et al. (2005, Planet. Space Sci. 53, 498-507), have raised interest in and a need for modeling of scattering properties of complex composite particles. Since many of the particle sizes inferred for composite particles are below or close to the range near 1 μm where particle shape has less impact on near IR spectral features (Clapp and Miller, 1993, Icarus 105, 529-536), concentric shell codes have considerable relevance to modeling of composite particles. Here we report on two codes: one fast code (Toon and Ackerman, 1981, Applied Optics 20, No. 20, 3657-3660) that is capable of handling a core and shell of different materials, and a slower code (Pena and Pal, 2009, Computer Physics Comm., 180, 2348-2354) that can handle an arbitrary number of layers. Typical times to calculate a phase function for a wide size distribution (gamma distribution with normalized variance of 0.1) for the faster core/shell code are about 0.75 seconds per wavelength. The newer slower, but more versatile, code runs about 10X slower, and will typically double or triple the execution time of our multiple scattering code when it is incorporated. Optimizing integration over particle size distributions to achieve suitable accuracy can minimize computational costs; we have therefore determined a rule for the number of intervals in the size distribution. Sample calculations will be presented to show effects

  3. Outdoor ultrafine particle concentrations in front of fast food restaurants.

    PubMed

    Vert, Cristina; Meliefste, Kees; Hoek, Gerard

    2016-01-01

    Ultrafine particles (UFPs) have been associated with negative effects on human health. Emissions from motor vehicles are the principal source of UFPs in urban air. A study in Vancouver suggested that UFP concentrations were related to density of fast food restaurants near the monitoring sites. A previous monitoring campaign could not separate the contribution of restaurants from road traffic. The main goal of this study has been the quantification of fast food restaurants' contribution to outdoor UFP concentrations. A portable particle number counter (DiscMini) has been used to carry out mobile monitoring in a largely pedestrianized area in the city center of Utrecht. A fixed route passing 17 fast food restaurants was followed on 8 days. UFP concentrations in front of the restaurants were 1.61 times higher than in a nearby square without any local sources used as control area and 1.22 times higher compared with all measurements conducted in between the restaurants. Adjustment for other sources such as passing mopeds, smokers or candles did not explain the increase. In conclusion, fast food restaurants result in significant increases in outdoor UFP concentrations in front of the restaurant. PMID:26531805

  4. Electrophoretic mobility of silica particles in a mixture of toluene and ethanol at different particle concentrations.

    PubMed

    Medrano, M; Pérez, A T; Lobry, L; Peters, F

    2009-10-20

    In this paper we present measurements of the electrophoretic mobility of colloidal particles by using heterodyne detection of light scattering. The measurements have been made up to concentrations of 5.4% silica nanoparticles, with a diameter on the order of 80 nm, in a mixture of 70% toluene and 30% ethanol. To make possible the measurements at these concentrations, the liquid mixture is chosen so as to match the index of refraction of the particles, thus resulting in a transparent suspension. PMID:19754057

  5. Assessment of EOS Aqua AMSR-E Arctic Sea Ice Concentrations using Landsat-7 and Airborne Microwave Imagery

    NASA Technical Reports Server (NTRS)

    Cavalieri, Donald J.; Markus, Thorsten; Hall, Dorothy K.; Gasiewski, Albin J.; Klein, Marian; Ivanoff, Alvaro

    2006-01-01

    An assessment of Advanced Microwave Scanning Radiometer Earth Observing System (AMSR-E) sea ice concentrations under winter conditions using ice concentrations derived from Landsat-7 Enhanced Thematic Mapper Plus (ETM+) imagery obtained during the March 2003 Arctic sea ice validation field campaign is presented. The National Oceanic and Atmospheric Administration Environmental Technology Laboratory's Airborne Polarimetric Scanning Radiometer Measurements, which were made from the National Aeronautics and Space Administration P 3B aircraft during the campaign, were used primarily as a diagnostic tool to understand the comparative results and to suggest improvements to the AMSR-E ice concentration algorithm. Based on the AMSR-E/ETM+ comparisons, a good overall agreement with little bias (approx. 1%) for areas of first year and young sea ice was found. Areas of new ice production result in a negative bias of about 5% in the AMSR-E ice concentration retrievals, with a root mean square error of 8%. Some areas of deep snow also resulted in an underestimate of the ice concentration (approx. 10%). For all ice types combined and for the full range of ice concentrations, the bias ranged from 0% to 3%, and the rms errors ranged from 1% to 7%, depending on the region. The new-ice and deep-snow biases are expected to be reduced through an adjustment of the new-ice and ice-type C algorithm tie points.

  6. Effect of particle hardness on the penetration behavior of fabrics intercalated with dry particles and concentrated particle-fluid suspensions.

    PubMed

    Kalman, Dennis P; Merrill, Richard L; Wagner, Norman J; Wetzel, Eric D

    2009-11-01

    The penetration behavior of Kevlar fabric intercalated with dry particles and shear thickening fluids (STF), highly concentrated fluid-particle suspensions, is presented. In particular, the role of particle hardness is explored by comparing fabric treatments containing SiO(2) particles, which are significantly harder than Kevlar, to treatments containing softer poly(methyl methacrylate) (PMMA) particles. The fabric testing includes yarn pull-out, quasi-static spike puncture, and ballistic penetration resistance, performed on single fabric layers. It was found that both dry particle and STF treatments resulted in improvements in fabric properties relative to neat or poly(ethylene glycol) (PEG) treated fabrics. On comparison of treatments with different particle hardness, the SiO(2) materials performed better in all tests than comparable PMMA materials, although the SiO(2) treatments caused yarn failure in pull-out testing, reducing the total pull-out energy. In addition, resistance to yarn pull-out was found to be substantially higher for STF-treated fabrics than for dry particle treated fabrics. However, both dry particle addition and STF treatments exhibited comparable enhancements in puncture and ballistic resistance. These observations suggest that viscous stress transfer, friction, and physical entrainment of hard particles into filaments contribute to the demonstrated improvements in the properties of protective fabrics treated with shear thickening fluids. PMID:20356133

  7. Characterization of ultrafine particle number concentration and new particle formation in urban environment of Taipei, Taiwan

    NASA Astrophysics Data System (ADS)

    Cheung, H. C.; Chou, C. C.-K.; Huang, W.-R.; Tsai, C.-Y.

    2013-04-01

    An intensive aerosol characterization experiment was performed at the Taipei Aerosol and Radiation Observatory (TARO, 25.02° N, 121.53° E) in the urban area of Taipei, Taiwan during July 2012. Number concentration and size distribution of aerosol particles were measured continuously, which were accompanied by concurrent measurements of mass concentration of submicron particles, PM (d ≤ 1 μm), and photolysis rate of ozone, J(O1D). The averaged number concentrations of total (Ntotal), accumulation mode (Nacu), Aitken mode (Ntotal), and nucleation mode (Nnuc) particles were 7.6 × 103 cm-3, 1.2 × 103 cm-3, 4.4 × 103 cm-3, and 1.9 × 103 cm-3, respectively. Accordingly, the ultrafine particles (UFPs, d ≤ 100 nm) accounted for 83% of the total number concentration of particles measured in this study (10 ≤ d ≤ 429 nm), indicating the importance of UFPs to the air quality and radiation budget in Taipei and its surrounding areas. An averaged Nnuc/NOx ratio of ~60 cm-3 ppbv-1 was derived from nighttime measurements, which was suggested to be the characteristic of vehicle emissions that contributed to the "urban background" of nucleation mode particles throughout a day. On the contrary, it was found that the number concentration of nucleation mode particles was independent of NOx and could be elevated up to 10 times the "urban background" levels during daytime, suggesting a substantial amount of nucleation mode particles produced from photochemical processes. Consistency in the time series of the nucleation mode particle concentration and the proxy of H2SO4 production, UVB·SO2, for new particle formation (NPF) events showed that photo-oxidation of SO2 was responsible for the formation of new particles in our study area. Moreover, analysis upon the diameter growth rate, GR, and formation rate of nucleation mode particles, J10-25, found that the values of GR (8.5 ± 6.8 nm h-1) in Taipei were comparable to other urban areas, whereas the values of J10-25 (2.2 ± 1

  8. Measurement of Particle Concentrations above a Forest and Surrounding Farmland

    NASA Astrophysics Data System (ADS)

    Valyou, D.; Butler, J.; Zito, E.; Hull, W.; Hoffman, J.; Mazocca, P.; Dhaniyala, S.; Hopke, P. K.; Barthelmie, R.; Scott, S.; Pryor, S. C.

    2008-12-01

    Very little information is currently available regarding the spatial scales on which nucleation occurs in the near surface layer. As part of the May 2008 Nucleation In ForesTs (NIFTY) campaign, an unmanned aerial vehicle (UAV) system was flown across the study area of the Morgan-Monroe State Forest (MMSF). The Clarkson Vector-P UAV carried a TSI Model 3007 Condensation Particle Counter (CPC) and a Grimm Model 1.109 Universal Aerosol Spectrometer (UAS). The CPC provides the count of ultrafine particles while the UAS gives counts of large particles (0.25 to 20 "Ým). These measurements were designed to supplement the extensive measurements being made on the 46 m instrumented tower. Because of the FAA restrictions of line-of-sight observation of the UAV by ground observers, we were limited in the spatial extent and were limited to studying altitudes below 1200 feet. However, these restrictions still permitted us to make a series of measurements of the spatial and vertical extent of particle concentrations to support the ground level composition measurements to better understand nucleation and growth in this rural area of southwestern Indiana.

  9. Influence of atmospheric ozone, PM 10 and meteorological factors on the concentration of airborne pollen and fungal spores

    NASA Astrophysics Data System (ADS)

    Sousa, S. I. V.; Martins, F. G.; Pereira, M. C.; Alvim-Ferraz, M. C. M.; Ribeiro, H.; Oliveira, M.; Abreu, I.

    The increase of allergenic symptoms has been associated with air contaminants such as ozone, particulate matter, pollen and fungal spores. Considering the potential relevance of crossed effects of non-biological pollutants and airborne pollens and fungal spores on allergy worsening, the aim of this work was to evaluate the influence of non-biological pollutants and meteorological parameters on the concentrations of pollen and fungal spores using linear correlations and multiple linear regressions. For that, the seasonal variation of ozone, particulate matter with an equivalent aerodynamic diameter smaller than 10 μm, pollen and fungal spores were assessed and statistical correlations were analysed between those parameters. The data were collected through 2003-2005 in Porto, Portugal. The linear correlations showed that ozone and particulate matter had no significant influence on the concentration of pollen and fungal spores. On the contrary, when using multiple linear regressions those parameters showed to have some influence on the biological pollutants, although results were different depending on the year analysed. Among the meteorological parameters analysed, temperature was the one that most influenced the pollen and fungal spores airborne concentrations, both when using linear and multiple linear correlations. Relative humidity also showed to have some influence on the fungal spore dispersion when multiple linear regressions were used. Nevertheless, the conclusions for each pollen and fungal spore were different depending on the analysed period, which means that the correlations identified as statistically significant may not be, even so, consistent enough. Furthermore, the comparison of the results here presented with those obtained by other authors for only one period should be made carefully.

  10. Statistics of particle concentration in free-surface turbulence

    SciTech Connect

    Bandi, Mahesh M; Larkin, J; Goldburg, W

    2009-01-01

    Particles on the surface of an incompressible fluid maintained in a turbulent steady-state cluster into spatio-temporally complex flow structures. We experimentally study the statistics of particle concentration n(r, t) over various coarse-grained scales r' in the inertial range. Another control parameter is the Taylor Microscale Reynolds number Re{sub {lambda}}. The focus is on the steady state probability density function {Pi}(n{sub r}). Attention is also given to the variance {sigma}{sup 2}(r, t) of this PDF, since it yields information about the topology of the coagulated structures. Where possible, the results are compared and contrasted with those obtained in a recent analytical and numerical study of two-dimensional synthetic turbulence by Ducasse and Pumir. There, but not here, the dimensionless compressibility C is an important control parameter.

  11. Environmentally relevant concentrations of microplastic particles influence larval fish ecology.

    PubMed

    Lönnstedt, Oona M; Eklöv, Peter

    2016-06-01

    The widespread occurrence and accumulation of plastic waste in the environment have become a growing global concern over the past decade. Although some marine organisms have been shown to ingest plastic, few studies have investigated the ecological effects of plastic waste on animals. Here we show that exposure to environmentally relevant concentrations of microplastic polystyrene particles (90 micrometers) inhibits hatching, decreases growth rates, and alters feeding preferences and innate behaviors of European perch (Perca fluviatilis) larvae. Furthermore, individuals exposed to microplastics do not respond to olfactory threat cues, which greatly increases predator-induced mortality rates. Our results demonstrate that microplastic particles operate both chemically and physically on larval fish performance and development. PMID:27257256

  12. Airborne black carbon concentrations over an urban region in western India-temporal variability, effects of meteorology, and source regions.

    PubMed

    Bapna, Mukund; Sunder Raman, Ramya; Ramachandran, S; Rajesh, T A

    2013-03-01

    This study characterizes over 5 years of high time resolution (5 min), airborne black carbon (BC) concentrations (July 2003 to December 2008) measured over Ahmedabad, an urban region in western India. The data were used to obtain different time averages of BC concentrations, and these averages were then used to assess the diurnal, seasonal, and annual variability of BC over the study region. Assessment of diurnal variations revealed a strong association between BC concentrations and vehicular traffic. Peaks in BC concentration were co-incident with the morning (0730 to 0830, LST) and late evening (1930 to 2030, LST) rush hour traffic. Additionally, diurnal variability in BC concentrations during major festivals (Diwali and Dushera during the months of October/November) revealed an increase in BC concentrations due to fireworks displays. Maximum half hourly BC concentrations during the festival days were as high as 79.8 μg m(-3). However, the high concentrations rapidly decayed suggesting that local meteorology during the festive season was favorable for aerosol dispersion. A multiple linear regression (MLR) model with BC as the dependent variable and meteorological parameters as independent variables was fitted. The variability in temperature, humidity, wind speed, and wind direction accounted for about 49% of the variability in measured BC concentrations. Conditional probability function (CPF) analysis was used to identify the geographical location of local source regions contributing to the effective BC measured (at 880 nm) at the receptor site. The east north-east (ENE) direction to the receptor was identified as a major source region. National highway (NH8) and two coal-fired thermal power stations (at Gandhinagar and Sabarmati) were located in the identified direction, suggesting that local traffic and power plant emissions were likely contributors to the measured BC. PMID:22777610

  13. Fine particle concentrations in buses and taxis in Florence, Italy

    NASA Astrophysics Data System (ADS)

    Fondelli, M. Cristina; Chellini, Elisabetta; Yli-Tuomi, Tarja; Cenni, Isabella; Gasparrini, Antonio; Nava, Silvia; Garcia-Orellana, Isabel; Lupi, Andrea; Grechi, Daniele; Mallone, Sandra; Jantunen, Matti

    On October 2004, a sampling survey was carried out in Florence to estimate urban fine particle exposure concentrations inside commuting vehicles during workdays characterized by heavy traffic. Portable samplers were positioned inside four regularly scheduled diesel-powered buses and four taxis during eight weekdays. Each sampler consisted of a 2.5 μm size pre-separator cyclone, a direct-reading data logging photometer (pDR-1200), and a 4 L min -1 filter sampler for the determination of PM 2.5 mass concentration. Based on reflectance analysis measurements, a PM 2.5 Black Smoke Index was determined for each filter, and the elemental composition of the PM 2.5 was analyzed by Particle Induced X-ray Emission (PIXE). PM 2.5 mass concentrations inside the vehicles correlated well with the urban ambient air PM 2.5 concentrations measured at the fixed-site monitoring stations. The PM 2.5 excess above the urban ambient level was on average 32 μg m -3 (range: 22-52 μg m -3) and 20 μg m -3 (range: 11-29 μg m -3) in buses and taxis, respectively. The PM 2.5-bound sulfur concentration was also higher in the buses than in the taxis. Based on daily Time-Microenvironment-Activity-Diary (TMAD) data, the Florentines spend on average 9.7% of their day in traffic, and the corresponding average exposure is approximately 12% of their daily PM 2.5 personal exposure. The obtained data could be used to plan interventions to minimize the PM 2.5 citizen exposures in commuting.

  14. Concentrations and size distributions of airborne influenza A viruses measured indoors at a health centre, a day-care centre and on aeroplanes.

    PubMed

    Yang, Wan; Elankumaran, Subbiah; Marr, Linsey C

    2011-08-01

    The relative importance of the aerosol transmission route for influenza remains contentious. To determine the potential for influenza to spread via the aerosol route, we measured the size distribution of airborne influenza A viruses. We collected size-segregated aerosol samples during the 2009-2010 flu season in a health centre, a day-care facility and onboard aeroplanes. Filter extracts were analysed using quantitative reverse transcriptase polymerase chain reaction. Half of the 16 samples were positive, and their total virus concentrations ranged from 5800 to 37,000 genome copies m(-3). On average, 64 per cent of the viral genome copies were associated with fine particles smaller than 2.5 µm, which can remain suspended for hours. Modelling of virus concentrations indoors suggested a source strength of 1.6±1.2×10(5) genome copies m(-3) air h(-1) and a deposition flux onto surfaces of 13±7 genome copies m(-2) h(-1) by Brownian motion. Over 1 hour, the inhalation dose was estimated to be 30±18 median tissue culture infectious dose (TCID50), adequate to induce infection. These results provide quantitative support for the idea that the aerosol route could be an important mode of influenza transmission. PMID:21300628

  15. Characterization of the interactions within fine particle mixtures in highly concentrated suspensions for advanced particle processing.

    PubMed

    Otsuki, Akira; Bryant, Gary

    2015-12-01

    This paper aims to summarize recent investigations into the dispersion of fine particles, and the characterization of their interactions, in concentrated suspensions. This summary will provide a better understanding of the current status of this research, and will provide useful feedback for advanced particle processing. Such processes include the fabrication of functional nanostructures and the sustainable beneficiation of complex ores. For example, there has been increasing demand for complex ore utilization due to the noticeable decrease in the accessibility of high grade and easily extractable ores. In order to maintain the sustainable use of mineral resources, the effective beneficiation of complex ores is urgently required. It can be successfully achieved only with selective particle/mineral dispersion/liberation and the assistance of mineralogical and particle characterization. PMID:26298173

  16. Mining in subarctic Canada: airborne PM2.5 metal concentrations in two remote First Nations communities.

    PubMed

    Liberda, Eric N; Tsuji, Leonard J S; Peltier, Richard E

    2015-11-01

    Airborne particulate matter arising from upwind mining activities is a concern for First Nations communities in the western James Bay region of Ontario, Canada. Aerosol chemical components were collected in 2011 from two communities in northern Ontario. The chemical and mass concentration data of particulate matter collected during this study shows a significant difference in PM2.5 in Attawapiskat compared to Fort Albany. Elemental profiles indicate enhanced levels of some tracers thought to arise from mining activities, such as, K, Ni, and crustal materials. Both communities are remote and isolated from urban and industrial pollution sources, however, Attawapiskat First Nation has significantly enhanced levels of particulate matter, and it is likely that some of this arises from upwind mining activities. PMID:26255141

  17. Optical detection of glucose concentration in samples with scattering particles.

    PubMed

    Lin, Li-Han; Lo, Yu-Lung; Liao, Chia-Chi; Lin, Jian-Xiang

    2015-12-10

    An optical-based method is proposed for measuring the glucose concentration of samples containing scattering particles. In the proposed approach, a Stokes-Mueller reflection-based polarimetry technique is used to solve the Mueller matrices of a turbid glucose sample with circular birefringence and depolarization properties given six incident lights with different polarization states. Using an error function defined as the difference between the simulated output Stokes vectors and the experimental ones, a genetic algorithm is used to inversely derive the optical rotation and depolarization parameters of the experimental sample corresponding to the glucose concentration and scattering depolarization effect, respectively. The validity of the proposed method is demonstrated using glucose samples containing 0.02 ml and 0.04 ml lipofundin, respectively. PMID:26836866

  18. MicroMED: a dust particle counter for the characterization of airborne dust close to the surface of Mars

    NASA Astrophysics Data System (ADS)

    Cozzolino, Fabio; Esposito, Francesca; Molfese, Cesare; Cortecchia, Fausto; Saggin, Bortolino; D'amato, Francesco

    2015-04-01

    Monitoring of airborne dust is very important in planetary climatology. Indeed, dust absorbs and scatter solar and thermal radiation, severely affecting atmospheric thermal structure, balance and dynamics (in terms of circulations). Wind-driven blowing of sand and dust is also responsible for shaping planetary surfaces through the formation of sand dunes and ripples, the erosion of rocks, and the creation and transport of soil particles. Dust is permanently present in the atmosphere of Mars and its amount varies with seasons. During regional or global dust storms, more than 80% of the incoming sunlight is absorbed by dust causing an intense atmospheric heating. Airborne dust is therefore a crucial climate component on Mars which impacts atmospheric circulations at all scales. Main dust parameters influencing the atmosphere heating are size distribution, abundance, albedo, single scattering phase function, imaginary part of the index of refraction. Moreover, major improvements of Mars climate models require, in addition to the standard meteorological parameters, quantitative information about dust lifting, transport and removal mechanisms. In this context, two major quantities need to be measured for the dust source to be understood: surface flux and granulometry. While many observations have constrained the size distribution of the dust haze seen from the orbit, it is still not known what the primary airborne dust (e.g. the recently lifted dust) is made of, size-wise. MicroMED has been designed to fill this gap. It will measure the abundance and size distribution of dust, not in the atmospheric column, but close to the surface, where dust is lifted, so to be able to monitor dust injection into the atmosphere. This has never been performed in Mars and other planets exploration. MicroMED is an Optical Particle Counter, analyzing light scattered from single dust particles to measure their size and abundance. A proper fluid-dynamic system, including a pump and a

  19. Particle-bound polycyclic aromatic hydrocarbon concentrations in transportation microenvironments

    NASA Astrophysics Data System (ADS)

    Houston, Douglas; Wu, Jun; Yang, Dongwoo; Jaimes, Guillermo

    2013-06-01

    This study is one of the first case studies to characterize the exposure of urban residents to traffic-related air pollution across locations and transportation microenvironments during everyday activities. Twenty-four adult residents of Boyle Heights, a neighborhood near downtown Los Angeles, carried a portable air pollution monitor and a Global Positioning Systems (GPS) tracking device for a total of 96 days. We found significant spatial and temporal variation in the particle-bound polycyclic aromatic hydrocarbon (pPAH) concentrations in transportation microenvironments. Average pPAH concentrations were higher while walking outdoors (190 ng m-3) compared to traveling in private passenger vehicles (138-155 ng m-3) or traveling in public transportation (61-124 ng m-3). Although travel comprised 5% of participant days, it was associated with 27% of overall daily pPAH exposure. Regression models explained 40-55% of the variation in daily average pPAH concentrations, and 40-44% of the variation in 1-min interval concentrations. Important factors included time spent traveling, travel speed, meteorological and nearby land use factors, time of day, and proximity to roadways. Although future research is needed to develop stronger predictive models, our study demonstrates portable tracking devices can provide a more complete, diurnal characterization of air pollution exposures for urban populations.

  20. Acoustofluidic particle manipulation inside a sessile droplet: four distinct regimes of particle concentration.

    PubMed

    Destgeer, Ghulam; Cho, Hyunjun; Ha, Byung Hang; Jung, Jin Ho; Park, Jinsoo; Sung, Hyung Jin

    2016-02-21

    In this study, we have investigated the motion of polystyrene microparticles inside a sessile droplet of water actuated by surface acoustic waves (SAWs), which produce an acoustic streaming flow (ASF) and impart an acoustic radiation force (ARF) on the particles. We have categorized four distinct regimes (R1-R4) of particle aggregation that depend on the particle diameter, the SAW frequency, the acoustic wave field (travelling or standing), the acoustic waves' attenuation length, and the droplet volume. The particles are concentrated at the centre of the droplet in the form of a bead (R1), around the periphery of the droplet in the form of a ring (R2), at the side of the droplet in the form of an isolated island (R3), and close to the centre of the droplet in the form of a smaller ring (R4). The ASF-based drag force, the travelling or standing SAW-based ARF, and the centrifugal force are utilized in various combinations to produce these distinct regimes. For simplicity, we fixed the fluid volume at 5 μL, varied the SAW actuation frequency (10, 20, 80, and 133 MHz), and tested several particle diameters in the range 1-30 μm to explicitly demonstrate the regimes R1-R4. We have further demonstrated the separation of particles (1 and 10 μm, 3 and 5 μm) using mixed regime configurations (R1 and R2, R2 and R4, respectively). PMID:26755271

  1. Historical ambient airborne asbestos concentrations in the United States - an analysis of published and unpublished literature (1960s-2000s).

    PubMed

    Abelmann, Anders; Glynn, Meghan E; Pierce, Jennifer S; Scott, Paul K; Serrano, Samantha; Paustenbach, Dennis J

    2015-01-01

    Outdoor concentrations of airborne asbestos have been measured throughout the US over time. However, a thorough review and analysis of these data has not been conducted. The purpose of this study is to characterize asbestos concentrations in ambient air by environment type (urban, rural) and by decade, using measurements collected in the absence of known asbestos emission sources. A total of 17 published and unpublished studies and datasets were identified that reported the results of 2058 samples collected from the 1960s through the 2000s across the US. Most studies did not report asbestos fiber type, and data based on different analytical methods (e.g. Phase Contrast Microscopy, Transmission Electron Microscopy, etc.) were combined in the dataset; however, only fibers ≥5 μm in length were considered. For a small subset of the measurements (n = 186, 9.0%), a conversion factor was used to convert mass-based data (e.g. ng/m(3)) to count-based values (i.e. f/cc ≥5 μm). The estimated overall mean and median ambient asbestos concentrations for the 1960s through 2000s were 0.00093 f/cc and 0.00022 f/cc, respectively. Concentrations generally increased from the 1960s through the early 1980s, after which they declined considerably. While asbestos use decreased throughout the 1970s, these results indicate that ambient concentrations peaked during the early 1980s, which suggests the possible contribution of abatement or demolition activities. Lastly, ambient asbestos concentrations were higher in urban than rural settings, which is consistent with the greater use of asbestos-containing materials in more densely populated areas. PMID:26671195

  2. Spatial variability of fine particle concentrations in three European areas

    NASA Astrophysics Data System (ADS)

    Hoek, Gerard; Meliefste, Kees; Cyrys, Josef; Lewné, Marie; Bellander, Tom; Brauer, Mike; Fischer, Paul; Gehring, Ulrike; Heinrich, Joachim; van Vliet, Patricia; Brunekreef, Bert

    Epidemiological studies of long-term air pollution effects have been hampered by difficulties in characterizing the spatial variation in air pollution. We conducted a study to assess the risk of long-term exposure to traffic-related air pollution for the development of inhalant allergy and asthma in children in Stockholm county, Munich and the Netherlands. Exposure to traffic-related air pollution was assessed through a 1-year monitoring program and regression modeling using exposure indicators. This paper documents the performance of the exposure monitoring strategy and the spatial variation of ambient particle concentrations. We measured the ambient concentration of PM2.5 and the reflectance of PM2.5 filters ('soot') at 40-42 sites representative of different exposure conditions of the three study populations. Each site was measured during four 14-day average sampling periods spread over one year (spring 1999 to summer 2000). In each study area, a continuous measurement site was operated to remove potential bias due to temporal variation. The selected approach was an efficient method to characterize spatial differences in annual average concentration between a large number of sites in each study area. Adjustment with data from the continuous measurement site improved the precision of the calculated annual averages, especially for PM2.5. Annual average PM2.5 concentrations ranged from 11 to 20 μg/m 3 in Munich, from 8 to 16 μg/m 3 in Stockholm and from 14 to 26 μg/m 3 in the Netherlands. Larger spatial contrasts were found for the absorption coefficient of PM2.5. PM2.5 concentrations were on average 17-18% higher at traffic sites than at urban background sites, but PM2.5 absorption coefficients at traffic sites were between 31% and 55% increased above background. This suggests that spatial variation of traffic-related air pollution may be underestimated if PM2.5 only is measured.

  3. Pb, Sr and Nd isotopic composition and trace element characteristics of coarse airborne particles collected with passive samplers

    NASA Astrophysics Data System (ADS)

    Hoàng-Hòa, Thi Bich; Stille, Peter; Dietze, Volker; Guéguen, Florence; Perrone, Thierry; Gieré, Reto

    2015-09-01

    Passive samplers for collection of coarse airborne particulate matter have been installed in and around the coal-mining town of Cam Pha, Quang Ninh Province (Vietnam). Analysis of Pb, Sr, and Nd isotope ratios and of major and trace element distribution patterns in atmospheric particulates collected at three stations allowed for the identification of four important dust components: (1) coal dust from an open-pit mine and fly ash particles from a coal-fired power station, (2) diesel soot, (3) traffic dust from metal, tire and pavement abrasion, and (4) limestone-derived dust. Outside of the coal-mining area, traffic-derived dust defines the atmospheric baseline composition of the studied environment.

  4. Airborne DOAS measurements in Arctic: vertical distributions of aerosol extinction coefficient and NO2 concentration

    NASA Astrophysics Data System (ADS)

    Merlaud, A.; van Roozendael, M.; Theys, N.; Fayt, C.; Hermans, C.; Quennehen, B.; Schwarzenboeck, A.; Ancellet, G.; Pommier, M.; Pelon, J.; Burkhart, J.; Stohl, A.; de Mazière, M.

    2011-05-01

    We report airborne differential optical absorption spectroscopy (DOAS) measurements of aerosol extinction and NO2 tropospheric profiles performed off the North coast of Norway in April 2008. The DOAS instrument was installed on the Safire ATR-42 aircraft during the POLARCAT-France spring campaign and recorded scattered light spectra in near-limb geometry using a scanning telescope. We use O4 slant column measurements to derive the aerosol extinction at 360 nm. Regularization is based on the maximum a posteriori solution, for which we compare a linear and a logarithmic approach. The latter inherently constrains the solution to positive values and yields aerosol extinction profiles more consistent with independently measured size distributions. Two soundings are presented, performed on 8 April 2008 above 71° N, 22° E and on 9 April 2008 above 70° N, 17.8° E. The first profile shows aerosol extinction and NO2 in the marine boundary layer with respective values of 0.04±0.005 km-1 and 1.9±0.3 × 109 molec cm-3. A second extinction layer of 0.01±0.003 km-1 is found at 4 km altitude. During the second sounding, clouds prevented us to retrieve profile parts under 3 km altitude but a layer with enhanced extinction (0.025±0.005 km-1) and NO2 (1.95±0.2 × 109 molec cm-3) is clearly detected at 4 km altitude. From CO and ozone in-situ measurements complemented by back-trajectories, we interpret the measurements in the free troposphere as, for the first sounding, a mix between stratospheric and polluted air from Northern Europe and for the second sounding, polluted air from Central Europe containing NO2. Considering the boundary layer measurements of the first flight, modeled source regions indicate closer sources, especially the Kola Peninsula smelters, which can explain the NO2 enhancement not correlated with a CO increase at the same altitude.

  5. Airborne Particles: What We Have Learned About Their Role in Climate from Remote Sensing, and Prospects for Future Advances

    NASA Technical Reports Server (NTRS)

    Kahn, Ralph A.

    2013-01-01

    Desert dust, wildfire smoke, volcanic ash, biogenic and urban pollution particles, all affect the regional-scale climate of Earth in places and at times; some have global-scale impacts on the column radiation balance, cloud properties, atmospheric stability structure, and circulation patterns. Remote sensing has played a central role in identifying the sources and transports of airborne particles, mapping their three-dimensional distribution and variability, quantifying their amount, and constraining aerosol air mass type. The measurements obtained from remote sensing have strengths and limitations, and their value for characterizing Earths environment is enhanced immensely when they are combined with direct, in situ observations, and used to constrain aerosol transport and climate models. A similar approach has been taken to study the role particles play in determining the climate of Mars, though based on far fewer observations. This presentation will focus what we have learned from remote sensing about the impacts aerosol have on Earths climate; a few points about how aerosols affect the climate of Mars will also be introduced, in the context of how we might assess aerosol-climate impacts more generally on other worlds.

  6. Vinyl flooring in the home is associated with children's airborne butylbenzyl phthalate and urinary metabolite concentrations.

    PubMed

    Just, Allan C; Miller, Rachel L; Perzanowski, Matthew S; Rundle, Andrew G; Chen, Qixuan; Jung, Kyung Hwa; Hoepner, Lori; Camann, David E; Calafat, Antonia M; Perera, Frederica P; Whyatt, Robin M

    2015-01-01

    Prior studies have shown that vinyl flooring as well as the vinyl-softening plasticizers butylbenzyl phthalate (BBzP) and di(2-ethylhexyl) phthalate (DEHP) are associated with asthma and airway inflammation. Although DEHP exposure is primarily dietary, whether home vinyl flooring contributes to indoor air and urinary metabolite concentrations for these two phthalates is unclear. Exposures to BBzP and DEHP were examined in a prospective birth cohort of New York City children (n=239) using: (i) visual observation of potential phthalate containing flooring, (ii) a 2-week home indoor air sample, and (iii) concurrent urinary metabolites in a subset (n=193). The category "vinyl or linoleum" flooring was observed in 135 (56%) of monitored rooms; these rooms had statistically significantly higher indoor air geometric mean concentrations of BBzP (23.9 ng/m(3)) than rooms with wood or carpet flooring (10.6 ng/m(3)). Children from homes with "vinyl or linoleum" flooring also had significantly higher urinary BBzP metabolite concentrations than other children. Indoor air BBzP and urinary metabolite concentrations were correlated positively (Spearman's rho 0.40). By contrast, indoor air DEHP was not associated with flooring type nor with its urinary metabolite concentrations. Vinyl flooring in the home may be an important source of children's exposure to BBzP via indoor air. PMID:25690585

  7. Spatial variations in airborne microorganism and endotoxin concentrations at green waste composting facilities.

    PubMed

    Pankhurst, L J; Deacon, L J; Liu, J; Drew, G H; Hayes, E T; Jackson, S; Longhurst, P J; Longhurst, J W S; Pollard, S J T; Tyrrel, S F

    2011-09-01

    The emission and dispersal of bioaerosols from open-air commercial composting facilities continues to be contentious. A meta-dataset enumerating cultivable microorganism emission and downwind concentrations is not yet available. A dataset derived from repeated and replicated field studies over a period of two years at two commercial composting facilities is presented. The data characterises patterns in Aspergillus fumigatus, actinomycetes, Gram-negative bacteria and endotoxin emission and downwind concentrations. For all bioaerosols, compost agitation activities had a significant impact on concentrations; levels were variable up to 600 m downwind from site. Bioaerosols declined rapidly from source and exhibited a secondary peak 100-150 m from site boundary. All bioaerosols were found downwind from site in elevated concentrations. Compared to those found 100 m upwind, levels were significantly higher at 180 m downwind for A. fumigatus; at 300-400 m for actinomycetes and Gram negative bacteria, and at 100 m for endotoxins. Periodically, elevated concentrations could be found for all bioaerosols at distances further downwind. The evidence provided by this data set provides operators and regulators of facilities with reliable data to inform the location, risk assessment and bioaerosol sampling strategies of commercial composting facilities. PMID:21737345

  8. Optical trapping and rotation of airborne absorbing particles with a single focused laser beam

    NASA Astrophysics Data System (ADS)

    Lin, Jinda; Li, Yong-qing

    2014-03-01

    We measure the periodic circular motion of single absorbing aerosol particles that are optically trapped with a single focused Gaussian beam and rotate around the laser propagation direction. The scattered light from the trapped particle is observed to be directional and change periodically at 0.4-20 kHz. The instantaneous positions of the moving particle within a rotation period are measured by a high-speed imaging technique using a charge coupled device camera and a repetitively pulsed light-emitting diode illumination. The centripetal acceleration of the trapped particle as high as ˜20 times the gravitational acceleration is observed and is attributed to the photophoretic forces.

  9. Optical trapping and rotation of airborne absorbing particles with a single focused laser beam

    SciTech Connect

    Lin, Jinda; Li, Yong-qing

    2014-03-10

    We measure the periodic circular motion of single absorbing aerosol particles that are optically trapped with a single focused Gaussian beam and rotate around the laser propagation direction. The scattered light from the trapped particle is observed to be directional and change periodically at 0.4–20 kHz. The instantaneous positions of the moving particle within a rotation period are measured by a high-speed imaging technique using a charge coupled device camera and a repetitively pulsed light-emitting diode illumination. The centripetal acceleration of the trapped particle as high as ∼20 times the gravitational acceleration is observed and is attributed to the photophoretic forces.

  10. Chemical characterisation of single airborne particles in Athens (Greece) by ATOFMS

    NASA Astrophysics Data System (ADS)

    Dall'Osto, Manuel; Harrison, Roy M.

    A TSI Model 3800 aerosol time-of-flight mass spectrometer (ATOFMS) was deployed for single-particle analysis to Athens (Greece) during August 2003. It has revealed particle types not previously reported in urban air, as well as adding appreciably to the knowledge of aerosol in the Athens atmosphere. Sampling was carried out on a minor road in the city centre and the mass spectra of 166,603 particles were recorded, with 128,290 presenting both positive and negative spectra. The ART-2a neural network algorithm was applied and five main classes of particle were characterised: sea salt, dust, carbon, inorganic and K-rich, with sub-classes within each. Dust (with five sub-classes) was the main class, accounting for up to 49.5% of the particles characterised. Oxygenated organic particles feature heavily in the dataset and some are internally mixed with nitrate and sulphate. Most of the carbon-containing particles appeared to be a secondary product of atmospheric chemistry and one specific class (C-SEC_2) peaked every night at 22:00, when temperature and RH values favoured condensation. The secondary particles showed clear internal mixing of organic and inorganic constituents in contrast to their common theoretical treatment as external mixtures. The apparent semi-volatility of one class was striking. Compared with measurements in northern Europe, the abundance of relatively coarse dust particles and of secondary organic particles is notable. The particle classes derived from analysis of the ATOFMS data were compared with published data on the composition of aerosol in Athens. The latter is largely restricted to major water-soluble ions, and the two measurement techniques proved to be highly complementary.

  11. ELECTRON MICROSCOPE MEASUREMENT OF AIRBORNE ASBESTOS CONCENTRATIONS - A PROVISIONAL METHODOLOGY MANUAL

    EPA Science Inventory

    This manual describes a provisional optimum electron microscope (EM) procedure for measuring the concentration of asbestos in air samples. The main features of the method include depositing an air sample on a polycarbonate membrane filter, examining an EM grid specimen in a trans...

  12. ELECTRON MICROSCOPE MEASUREMENT OF AIRBORNE ASBESTOS CONCENTRATIONS. A PROVISIONAL METHODOLOGY MANUAL

    EPA Science Inventory

    This manual describes a provisional optimum electron microscope (EM) procedure for measuring the concentration of asbestos in air samples. The main features of the method include depositing an air sample on a polycarbonate membrane filter, examining an EM grid specimen in a trans...

  13. Impact of spatiotemporal fluctuations in airborne chemical concentration on toxic hazard assessment.

    PubMed

    Bogen, K T; Gouveia, F J

    2008-03-21

    Models widely used to assess atmospheric chemical-dispersion hazards for emergency response rely on acute exposure guideline level (AEGL) or similar concentration guidelines to map geographic areas potentially affected by corresponding levels of toxic severity. By ignoring substantial, random variability in concentration over time and space, such standard methods routinely underestimate the size of potentially affected areas. Underestimation due to temporal fluctuation - applicable to chemicals like hydrogen cyanide (HCN) for which peak concentrations best predict acute toxicity - becomes magnified by spatial fluctuation, defined as heterogeneity in average concentration at each location relative to standard-method predictions. The combined impact of spatiotemporal fluctuation on size of assessed threat areas was studied using a statistical-simulation assessment method calibrated to Joint Urban 2003 Oklahoma City field-tracer data. For a hypothetical 60-min urban release scenario involving HCN gas, the stochastic method predicted that lethal/severe effects could occur in an area 18 or 25 times larger than was predicted by standard methods targeted to a 60-min AEGL, assuming wind speeds > or =2.0 or < or =1.5m/s, respectively. The underestimation doubled when the standard method was targeted to a 10-min AEGL. Further research and field data are needed for improved stochastic methods to assess spatiotemporal fluctuation effects. PMID:17706864

  14. Performance of a scanning mobility particle sizer in measuring diverse types of airborne nanoparticles: Multi-walled carbon nanotubes, welding fumes, and titanium dioxide spray.

    PubMed

    Chen, Bean T; Schwegler-Berry, Diane; Cumpston, Amy; Cumpston, Jared; Friend, Sherri; Stone, Samuel; Keane, Michael

    2016-07-01

    Direct-reading instruments have been widely used for characterizing airborne nanoparticles in inhalation toxicology and industrial hygiene studies for exposure/risk assessments. Instruments using electrical mobility sizing followed by optical counting, e.g., scanning or sequential mobility particle spectrometers (SMPS), have been considered as the "gold standard" for characterizing nanoparticles. An SMPS has the advantage of rapid response and has been widely used, but there is little information on its performance in assessing the full spectrum of nanoparticles encountered in the workplace. In this study, an SMPS was evaluated for its effectiveness in producing "monodisperse" aerosol and its adequacy in characterizing overall particle size distribution using three test aerosols, each mimicking a unique class of real-life nanoparticles: singlets of nearly spherical titanium dioxide (TiO2), agglomerates of fiber-like multi-walled carbon nanotube (MWCNT), and aggregates that constitutes welding fume (WF). These aerosols were analyzed by SMPS, cascade impactor, and by counting and sizing of discrete particles by scanning and transmission electron microscopy. The effectiveness of the SMPS to produce classified particles (fixed voltage mode) was assessed by examination of the resulting geometric standard deviation (GSD) from the impactor measurement. Results indicated that SMPS performed reasonably well for TiO2 (GSD = 1.3), but not for MWCNT and WF as evidenced by the large GSD values of 1.8 and 1.5, respectively. For overall characterization, results from SMPS (scanning voltage mode) exhibited particle-dependent discrepancies in the size distribution and total number concentration compared to those from microscopic analysis. Further investigation showed that use of a single-stage impactor at the SMPS inlet could distort the size distribution and underestimate the concentration as shown by the SMPS, whereas the presence of vapor molecules or atom clusters in some test

  15. Performance of a Scanning Mobility Particle Sizer in Measuring Diverse Types of Airborne Nanoparticles: Multi-Walled Carbon Nanotubes, Welding Fumes, and Titanium Dioxide Spray

    PubMed Central

    Chen, Bean T.; Schwegler-Berry, Diane; Cumpston, Amy; Cumpston, Jared; Friend, Sherri; Stone, Samuel; Keane, Michael

    2016-01-01

    Direct-reading instruments have been widely used for characterizing airborne nanoparticles in inhalation toxicology and industrial hygiene studies for exposure/risk assessments. Instruments using electrical mobility sizing followed by optical counting, e.g., scanning or sequential mobility particle spectrometers (SMPS), have been considered as the “gold standard” for characterizing nanoparticles. An SMPS has the advantage of rapid response and has been widely used, but there is little information on its performance in assessing the full spectrum of nanoparticles encountered in the workplace. In this study, an SMPS was evaluated for its effectiveness in producing “monodisperse” aerosol and its adequacy in characterizing overall particle size distribution using three test aerosols, each mimicking a unique class of real-life nanoparticles: singlets of nearly spherical titanium dioxide (TiO2), agglomerates of fiber-like multi-walled carbon nanotube (MWCNT), and aggregates that constitutes welding fume (WF). These aerosols were analyzed by SMPS, cascade impactor, and by counting and sizing of discrete particles by scanning and transmission electron microscopy. The effectiveness of the SMPS to produce classified particles (fixed voltage mode) was assessed by examination of the resulting geometric standard deviation (GSD) from the impactor measurement. Results indicated that SMPS performed reasonably well for TiO2 (GSD = 1.3), but not for MWCNT and WF as evidenced by the large GSD values of 1.8 and 1.5, respectively. For overall characterization, results from SMPS (scanning voltage mode) exhibited particle-dependent discrepancies in the size distribution and total number concentration compared to those from microscopic analysis. Further investigation showed that use of a single-stage impactor at the SMPS inlet could distort the size distribution and underestimate the concentration as shown by the SMPS, whereas the presence of vapor molecules or atom clusters in

  16. Characterisation of indoor airborne particles by using real-time aerosol mass spectrometry.

    PubMed

    Dall'Osto, Manuel; Harrison, Roy M; Charpantidou, E; Loupa, G; Rapsomanikis, S

    2007-10-01

    An Aerosol Time-of-Flight Mass Spectrometer (ATOFMS; TSI 3800) was deployed to Athens (Greece) during August 2003. The instrument provides information on a polydisperse aerosol, acquiring precise aerodynamic diameter (+/-1%) within the range 0.3 to 3 mum and individual particle positive and negative mass spectral data in real time. Sampling was carried out indoors and outdoors at an office in a building on a minor road in the city centre and various outdoor and indoor sources were identified. Specific outdoor particles such as dust and carbon particles were detected in indoor air. The generation of particles from indoor sources was studied and several different types of particle were found to be present in environmental tobacco smoke (ETS): three were potassium-rich (with differing proportions of carbon) emitted directly in the exhaled mainstream smoke. Two other types arose mainly when the cigarette was left smouldering on an ash-tray. Another particle type exhibited a strong signal at m/z 84, most likely due to a nicotine fragment. The temporal trend of this specific particle type showed likely condensation of semi-volatile constituents on existing potassium-rich particles. A release of insect repellent in the room was also successfully monitored. PMID:17628640

  17. Trends and threshold exceedances analysis of airborne pollen concentrations in Metropolitan Santiago Chile

    PubMed Central

    Toro A., Richard; Córdova J., Alicia; Canales, Mauricio; Morales S., Raul G. E.; Mardones P., Pedro; Leiva G., Manuel A.

    2015-01-01

    Pollen is one of the primary causes of allergic rhinoconjunctivitis in urban centers. In the present study, the concentrations of 39 different pollens in the Santiago de Chile metropolitan area over the period 2009–2013 are characterized. The pollen was monitored daily using Burkard volumetric equipment. The contribution of each type of pollen and the corresponding time trends are evaluated. The concentrations of the pollens are compared with the established threshold levels for the protection of human health. The results show that the total amount of pollen grains originating from trees, grasses, weeds and indeterminate sources throughout the period of the study was 258,496 grains m-3, with an annual average of 51,699 ± 3,906 grains m-3 year-1. The primary source of pollen is Platanus orientalis, which produces 61.8% of the analyzed pollen. Grass pollen is the third primary component of the analyzed pollen, with a contribution of 5.82%. Among the weeds, the presence of Urticacea (3.74%) is remarkable. The pollination pattern of the trees is monophasic, and the grasses have a biphasic pattern. The trends indicate that the total pollen and tree pollen do not present a time trend that is statistically significant throughout the period of the study, whereas the grass pollen and weed pollen concentrations in the environment present a statistically significant decreasing trend. The cause of this decrease is unclear. The pollen load has doubled over the past decade. When the observed concentrations of the pollens were compared with the corresponding threshold levels, the results indicated that over the period of the study, the pollen concentrations were at moderate, high and very high levels for an average of 293 days per year. Systematic counts of the pollen grains are an essential method for diagnosing and treating patients with pollinosis and for developing forestation and urban planning strategies. PMID:25946339

  18. Trends and threshold exceedances analysis of airborne pollen concentrations in Metropolitan Santiago Chile.

    PubMed

    Toro A, Richard; Córdova J, Alicia; Canales, Mauricio; Morales S, Raul G E; Mardones P, Pedro; Leiva G, Manuel A

    2015-01-01

    Pollen is one of the primary causes of allergic rhinoconjunctivitis in urban centers. In the present study, the concentrations of 39 different pollens in the Santiago de Chile metropolitan area over the period 2009-2013 are characterized. The pollen was monitored daily using Burkard volumetric equipment. The contribution of each type of pollen and the corresponding time trends are evaluated. The concentrations of the pollens are compared with the established threshold levels for the protection of human health. The results show that the total amount of pollen grains originating from trees, grasses, weeds and indeterminate sources throughout the period of the study was 258,496 grains m-3, with an annual average of 51,699 ± 3,906 grains m-3 year-1. The primary source of pollen is Platanus orientalis, which produces 61.8% of the analyzed pollen. Grass pollen is the third primary component of the analyzed pollen, with a contribution of 5.82%. Among the weeds, the presence of Urticacea (3.74%) is remarkable. The pollination pattern of the trees is monophasic, and the grasses have a biphasic pattern. The trends indicate that the total pollen and tree pollen do not present a time trend that is statistically significant throughout the period of the study, whereas the grass pollen and weed pollen concentrations in the environment present a statistically significant decreasing trend. The cause of this decrease is unclear. The pollen load has doubled over the past decade. When the observed concentrations of the pollens were compared with the corresponding threshold levels, the results indicated that over the period of the study, the pollen concentrations were at moderate, high and very high levels for an average of 293 days per year. Systematic counts of the pollen grains are an essential method for diagnosing and treating patients with pollinosis and for developing forestation and urban planning strategies. PMID:25946339

  19. 3D Trace gas concentration distributions from groundbased and airborne tomographic DOAS measurements

    NASA Astrophysics Data System (ADS)

    Pundt, I.; Hak, C.; Hartl, A.; Heue, K.-P.; Knab, V.; Kunz, C.; Laepple, T.; Lee, W.-D.; Mettendorf, K. U.; Sun, H.

    2003-04-01

    An overview on the AFO-2000 project "Tom-DOAS" is given. The project aims the assessment of concentration maps from DOAS measurements performed from ground or aircraft with more than ten light beams. 1) A first ground-based experiment was set up in April/May 2001 during the motorway campaign BABII (organised by Fiedler et al.): Two DOAS telescopes were directed onto eight retro reflector arrays mounted on two cranes, providing 16 light beams in total. From the data Luff and Lee profiles and the emission plumes of NO2 and ozone could be derived. 2) A new telescope type, the Multibeam telescope, was developed for the simultaneous measurement of multiple paths at ground. 3) An aircraft instrument was developed and about 20 flight hours of Tom-DOAS measurements were performed onboard a Partenavia aircraft in the Milano area (Italy) in the frame of the EU "FORMAT" project (July/August 2002) - in co-operation with the Institut für Umweltphysik of the University of Bremen 4) A new inversion software, "TOMOLAB", was developed, which converts the DOAS column data to concentration maps. It is used for the optimisation of tomographic setups using model data, e.g. for flight track choices, as well as for the inversion of real data sets from the measurements.

  20. Airborne fine particulate pollution in Jinan, China: Concentrations, chemical compositions and influence on visibility impairment

    NASA Astrophysics Data System (ADS)

    Yang, Lingxiao; Zhou, Xuehua; Wang, Zhe; Zhou, Yang; Cheng, Shuhui; Xu, Pengju; Gao, Xiaomei; Nie, Wei; Wang, Xinfeng; Wang, Wenxing

    2012-08-01

    Daily PM2.5 samples were collected simultaneously at an urban site (SD) and a rural site (MP) in Jinan, China from March 2006 to February 2007. The samples were analyzed for major inorganic and organic water-soluble ions, 24 elements and carbonaceous species to determine the spatial and temporal variations of PM2.5 mass concentrations and chemical compositions and evaluate their contributions to visibility impairment. The annual average concentrations of PM2.5 were 148.71 μg m-3 and 97.59 μg m-3 at SD and MP, respectively. The predominant component of PM2.5 was (NH4)2SO4 at SD and organic mass at MP, which accounted for 28.71% and 37.25% of the total mass, respectively. The higher SOR (sulfur oxidation ratio) and ratios of OC/EC at SD indicated that the formation of secondary inorganic ions and secondary organic aerosols (SOA) could be accelerated in the urban area. Large size (NH4)2SO4 and large size organic mass were the most important contributors to visibility impairment at SD and MP, accounting for 43.80% and 41.02% of the light extinction coefficient, respectively.

  1. A survey of airborne HDI, HDI-based polyisocyanate and solvent concentrations in the manufacture and application of polyurethane coatings.

    PubMed

    Myer, H E; O'Block, S T; Dharmarajan, V

    1993-11-01

    This study summarizes the results of industrial hygiene surveys performed between 1979 and 1987 in paint manufacturing and application operations using polyurethane coatings containing hexamethylene diisocyanate (HDI) and HDI-based polyisocyanates (trade name Desmodur N). A total of 466 Desmodur N and 457 HDI samples were collected from 47 operations most of which were in application. The application surveys covered manufacture and refinishing of transportation vehicles, painting of large military and civilian equipment, industrial finishing operations, and maintenance and construction operations. The primary objective of the surveys was to assess the potential exposure to HDI and HDI-based polyisocyanate. In more than 60% of the surveys, concentrations of airborne organic solvents also were monitored. Isocyanates were sampled using toluene/nitroreagent in midget impingers, and solvents were collected using charcoal tubes. They were analyzed using high pressure liquid chromatography and gas chromatography, respectively. The data from these workplace situations show there is some potential for isocyanate overexposure of unprotected workers and that it is greater in spray than in nonspray operations. PMID:8256690

  2. Conditional-sampling spectrograph detection system for fluorescence measurements of individual airborne biological particles.

    PubMed

    Nachman, P; Chen, G; Pinnick, R G; Hill, S C; Chang, R K; Mayo, M W; Fernandez, G L

    1996-03-01

    We report the design and operation of a prototype conditional-sampling spectrograph detection system that can record the fluorescence spectra of individual, micrometer-sized aerosols as they traverse an intense 488-nm intracavity laser beam. The instrument's image-intensified CCD detector is gated by elastic scattering or by undispersed fluorescence from particles that enter the spectrograph's field of view. It records spectra only from particles with preselected scattering-fluorescence levels (a fiber-optic-photomultiplier subsystem provides the gating signal). This conditional-sampling procedure reduces data-handling rates and increases the signal-to-noise ratio by restricting the system's exposures to brief periods when aerosols traverse the beam. We demonstrate these advantages by reliably capturing spectra from individual fluorescent microspheres dispersed in an airstream. The conditional-sampling procedure also permits some discrimination among different types of particles, so that spectra may be recorded from the few interesting particles present in a cloud of background aerosol. We demonstrate such discrimination by measuring spectra from selected fluorescent microspheres in a mixture of two types of microspheres, and from bacterial spores in a mixture of spores and nonfluorescent kaolin particles. PMID:21085216

  3. Airborne observed and receptor-oriented modelled urban increments of anthropogenic CO2, CO and NOX concentrations in the megacity of London in summer 2012

    NASA Astrophysics Data System (ADS)

    Font Font, Anna Maria; Morguí, Josep Anton; Lee, James; McQuaid, Jim B.; Barratt, Benjamin

    2014-05-01

    A better characterization of the emissions and the dynamics of anthropogenic CO2 in large-urban centres are needed to implement more effective mitigation measures to combat climate change. This study aims to establish a representative emissions ratio of anthropogenic CO2 (CO2ff) in the megacity of London using CO and NOX as tracers. Observations of CO2, CO and NOX mixing ratios obtained onboard the NERC-ARSF aircraft undertaken on 12 July 2012 over the city of London were used. Airborne observations were taken at ~380 m along four transects crossing London, two in the morning (10:30 to 12:30 GMT) and two in the afternoon (15:30-16:30 GMT). The ratio of the amounts of CO and CO2 in excess of natural abundances (denoted as ΔCO and ΔCO2, respectively) from the airborne observations was used to determine the fraction of CO2 derived from burning fossil fuels (CO2ff). Total observations of CO and CO2 were compared to NOX observations and background concentrations were determined as the intercept when NOX mixing ratios equalled zero derived from standardised major axis linear regression. Excess concentrations were calculated by subtracting total amounts minus the background. ΔCO showed good correlation with ΔCO2 in the morning transects (R=0.95) but not in the afternoon (R=-0.50). The mean (±1σ) CO/CO2ff was derived from linear regression using the morning measurements and valued 5.0±0.4 ppb ppm-1. Lagrangian Particle Dispersion (LPD) simulations in backward mode were undertaken to model urban increments of anthropogenic CO2 and CO and to calculate the emissions ratio from the emissions inventory EDGAR v4.2. The LPD model FLEXPART was run with the meteorological data from the European Centre for Medium-Range Weather Forecasts (spatial resolution of 0.2 x 0.2 degrees; 91 vertical levels) and multiplied with the EDGAR emissions inventory (spatial resolution 0.1 x 0.1 degrees) to obtain an increment at each receptor point along the transects. Annual and temporal

  4. Guarded capacitance probes for measuring particle concentration and flow

    DOEpatents

    Louge, M.Y.

    1995-10-17

    Guarded capacitance probe structures are constructed with guard electrodes surrounding one or more sensor electrodes and ground electrodes or grounded surfaces surrounding the guard electrodes. In a one sensor embodiment, the probe utilizes an apertured sensor electrode and the guard electrode both surrounds the sensor electrode and fills the aperture. This embodiment is particularly useful for measuring particle concentration in a fluid suspension contained within a vessel or pipe. The portion of the guard electrode within the aperture of the sensor electrode prevents electric field lines from emanating from the sensor electrode into the fluid suspension and toward infinity. A two sensor embodiment of the probe is useful for measuring flow velocities of fluid suspensions through cross correlation of the outputs generated by each sensor. The relative dimensions of the guard and sensor electrodes are selected to provide the most accurate measurements by confining the electric lines emanating from the sensor electrode or electrodes and terminating on the surrounding grounded surfaces to a small measurement volume of the fluid suspension near the vessel or pipe wall. 14 figs.

  5. Guarded capacitance probes for measuring particle concentration and flow

    DOEpatents

    Louge, M.Y.

    1996-08-13

    Guarded capacitance probe structures are constructed with guard electrodes surrounding one or more sensor electrodes and ground electrodes or grounded surfaces surrounding the guard electrodes. In a one sensor embodiment, the probe utilizes an apertured sensor electrode and the guard electrode both surrounds the sensor electrode and fills the aperture. This embodiment is particularly useful for measuring particle concentration in a fluid suspension contained within a vessel or pipe. The portion of the guard electrode within the aperture of the sensor electrode prevents electric field lines from emanating from the sensor electrode into the fluid suspension and toward infinity. A two sensor embodiment of the probe is useful for measuring flow velocities of fluid suspensions through cross correlation of the outputs generated by each sensor. The relative dimensions of the guard and sensor electrodes are selected to provide the most accurate measurements by confining the electric lines emanating from the sensor electrode or electrodes and terminating on the surrounding grounded surfaces to a small measurement volume of the fluid suspension near the vessel or pipe wall. 14 figs.

  6. Guarded capacitance probes for measuring particle concentration and flow

    DOEpatents

    Louge, Michel Y.

    1995-01-01

    Guarded capacitance probe structures are constructed with guard electrodes surrounding one or more sensor electrodes and ground electrodes or grounded surfaces surrounding the guard electrodes. In a one sensor embodiment, the probe utilizes an apertured sensor electrode and the guard electrode both surrounds the sensor electrode and fills the aperture. This embodiment is particularly useful for measuring particle concentration in a fluid suspension contained within a vessel or pipe. The portion of the guard electrode within the aperture of the sensor electrode prevents electric field lines from emanating from the sensor electrode into the fluid suspension and toward infinity. A two sensor embodiment of the probe is useful for measuring flow velocities of fluid suspensions through cross correlation of the outputs generated by each sensor. The relative dimensions of the guard and sensor electrodes are selected to provide the most accurate measurements by confining the electric lines emanating from the sensor electrode or electrodes and terminating on the surrounding grounded surfaces to a small measurement volume of the fluid suspension near the vessel or pipe wall.

  7. Guarded capacitance probes for measuring particle concentration and flow

    DOEpatents

    Louge, Michel Y.

    1996-01-01

    Guarded capacitance probe structures are constructed with guard electrodes surrounding one or more sensor electrodes and ground electrodes or grounded surfaces surrounding the guard electrodes. In a one sensor embodiment, the probe utilizes an apertured sensor electrode and the guard electrode both surrounds the sensor electrode and fills the aperture. This embodiment is particularly useful for measuring particle concentration in a fluid suspension contained within a vessel or pipe. The portion of the guard electrode within the aperture of the sensor electrode prevents electric field lines from emanating from the sensor electrode into the fluid suspension and toward infinity. A two sensor embodiment of the probe is useful for measuring flow velocities of fluid suspensions through cross correlation of the outputs generated by each sensor. The relative dimensions of the guard and sensor electrodes are selected to provide the most accurate measurements by confining the electric lines emanating from the sensor electrode or electrodes and terminating on the surrounding grounded surfaces to a small measurement volume of the fluid suspension near the vessel or pipe wall.

  8. Automated classification of single airborne particles from two-dimensional angle-resolved optical scattering (TAOS) patterns by non-linear filtering

    NASA Astrophysics Data System (ADS)

    Crosta, Giovanni Franco; Pan, Yong-Le; Aptowicz, Kevin B.; Casati, Caterina; Pinnick, Ronald G.; Chang, Richard K.; Videen, Gorden W.

    2013-12-01

    Measurement of two-dimensional angle-resolved optical scattering (TAOS) patterns is an attractive technique for detecting and characterizing micron-sized airborne particles. In general, the interpretation of these patterns and the retrieval of the particle refractive index, shape or size alone, are difficult problems. By reformulating the problem in statistical learning terms, a solution is proposed herewith: rather than identifying airborne particles from their scattering patterns, TAOS patterns themselves are classified through a learning machine, where feature extraction interacts with multivariate statistical analysis. Feature extraction relies on spectrum enhancement, which includes the discrete cosine FOURIER transform and non-linear operations. Multivariate statistical analysis includes computation of the principal components and supervised training, based on the maximization of a suitable figure of merit. All algorithms have been combined together to analyze TAOS patterns, organize feature vectors, design classification experiments, carry out supervised training, assign unknown patterns to classes, and fuse information from different training and recognition experiments. The algorithms have been tested on a data set with more than 3000 TAOS patterns. The parameters that control the algorithms at different stages have been allowed to vary within suitable bounds and are optimized to some extent. Classification has been targeted at discriminating aerosolized Bacillus subtilis particles, a simulant of anthrax, from atmospheric aerosol particles and interfering particles, like diesel soot. By assuming that all training and recognition patterns come from the respective reference materials only, the most satisfactory classification result corresponds to 20% false negatives from B. subtilis particles and <11% false positives from all other aerosol particles. The most effective operations have consisted of thresholding TAOS patterns in order to reject defective ones

  9. Characterization of airborne individual particles collected in an urban area, a satellite city and a clean air area in Beijing, 2001

    NASA Astrophysics Data System (ADS)

    Shi, Zongbo; Shao, Longyi; Jones, T. P.; Whittaker, A. G.; Lu, Senlin; Bérubé, K. A.; He, Taoe; Richards, R. J.

    Collection campaigns for PM 10 and PM 2.5 have been conducted in a northwestern Beijing urban area in monthly periods over 2001, with 7 days collection per month. The samples were also collected simultaneously in a satellite city, Nankou, and a clean air area near the Ming Tombs Reservoir (MTR) over the domestic heating (March) and non-heating (July/August) periods in 2001 (both for one week). To assist the analysis, three types of 'source' particulate matter (PM) samples were taken. These consisted of coal combustion ash collected on top of a coke oven; dust storm particles collected during dust storm periods; and roadside PM 10 collected on a major road in Beijing. Monitoring results reveal that, in the urban area, particle mass levels were higher in winter than in other seasons. The 1-week/month average PM 10 mass levels were over 250 μg m -3 in winter. The particle mass levels in the satellite city were slightly lower than those at the urban site, and the lowest mass levels occurred at the MTR site. The morphology and chemical composition of individual airborne particles were determined by scanning electron microscopy, and image analysis was employed to study the number-size distributions. The number-size distributions of mineral particles showed that those in the Asia-Dust storm (ADS) collections are mostly coarser than 1 μm, while mineral particles of the non-ADS collections are predominately finer than 1 μm. The particles in the respirable (<2.5 μm) fraction accounted for 99% of the total particles in airborne PM samples. Soot aggregates were generally the most abundant components in airborne PM samples at all three sites. The fly ash (spherical) particles at the MTR site were significantly enriched over the heating period, indicating a domestic coal-burning source.

  10. Seasonal and intradiurnal variation of airborne pollen concentrations in Bodrum, SW Turkey.

    PubMed

    Tosunoglu, Aycan; Bicakci, Adem

    2015-04-01

    An aeropalynological study was performed in Bodrum, the famous tourism center in southwestern Turkey with a Hirst-type volumetric 7-day pollen and spore trap for 2 years (2007-2008). In Bodrum, 25,099 pollen grains as a mean value belonging to 41 taxa were recorded annually during the study period, and pollen grains from woody plant taxa had the largest atmospheric contribution of 86.99% and 24 taxa. However, 17 herbaceous plant taxa constituted 12.82% of the annual total pollen count, and 0.19% were unidentified. An average annual pollen index of 22.66% was recorded in March, despite differences from year to year. The highest pollen variability of 34 taxa was recorded in April and May. Predominant pollen types belonged to Cupressaceae/Taxaceae (42.73%), Quercus (15.95%), Pinus (9.78%), Olea europaea (9.04%), Poaceae (5.50%), Betula (1.82%), Pistacia (1.74%), Morus (1.72%), Urticaceae (1.46%), and Plantago (1.28%) and generated 91.03 of the annual total. In total, 32.59% of the mean annual total pollen index was recorded in the morning, and less pollen was recorded in the evening (18.71%). Maximum pollen concentration was recorded between 11:00 and 12:00 a.m. PMID:25750068

  11. Exposure to Airborne Particles and Volatile Organic Compounds from Polyurethane Molding, Spray Painting, Lacquering, and Gluing in a Workshop

    PubMed Central

    Mølgaard, Bjarke; Viitanen, Anna-Kaisa; Kangas, Anneli; Huhtiniemi, Marika; Larsen, Søren Thor; Vanhala, Esa; Hussein, Tareq; Boor, Brandon E.; Hämeri, Kaarle; Koivisto, Antti Joonas

    2015-01-01

    Due to the health risk related to occupational air pollution exposure, we assessed concentrations and identified sources of particles and volatile organic compounds (VOCs) in a handcraft workshop producing fishing lures. The work processes in the site included polyurethane molding, spray painting, lacquering, and gluing. We measured total VOC (TVOC) concentrations and particle size distributions at three locations representing the various phases of the manufacturing and assembly process. The mean working-hour TVOC concentrations in three locations studied were 41, 37, and 24 ppm according to photo-ionization detector measurements. The mean working-hour particle number concentration varied between locations from 3000 to 36,000 cm−3. Analysis of temporal and spatial variations of TVOC concentrations revealed that there were at least four substantial VOC sources: spray gluing, mold-release agent spraying, continuous evaporation from various lacquer and paint containers, and either spray painting or lacquering (probably both). The mold-release agent spray was indirectly also a major source of ultrafine particles. The workers’ exposure can be reduced by improving the local exhaust ventilation at the known sources and by increasing the ventilation rate in the area with the continuous source. PMID:25849539

  12. Temperature dependence of the particle/gas partition coefficient: An application to predict indoor gas-phase concentrations of semi-volatile organic compounds.

    PubMed

    Wei, Wenjuan; Mandin, Corinne; Blanchard, Olivier; Mercier, Fabien; Pelletier, Maud; Le Bot, Barbara; Glorennec, Philippe; Ramalho, Olivier

    2016-09-01

    The indoor gas-phase concentrations of semi-volatile organic compounds (SVOCs) can be predicted from their respective concentrations in airborne particles by applying the particle/gas partitioning equilibrium. The temperature used for partitioning is often set to 25°C. However, indoor temperatures frequently differ from this reference value. This assumption may result in errors in the predicted equilibrium gas-phase SVOC concentrations. To improve the prediction model, the temperature dependence of the particle/gas partition coefficient must be addressed. In this paper, a theoretical relationship between the particle/gas partition coefficient and temperature was developed based on the SVOC absorptive mechanism. The SVOC particle/gas partition coefficients predicted by employing the derived theoretical relationship agree well with the experimental data retrieved from the literature (R>0.93). The influence of temperature on the equilibrium gas-phase SVOC concentration was quantified by a dimensionless analysis of the derived relationship between the SVOC particle/gas partition coefficient and temperature. The predicted equilibrium gas-phase SVOC concentration decreased by between 31% and 53% when the temperature was lowered by 6°C, while it increased by up to 750% when the indoor temperature increased from 15°C to 30°C. PMID:27152992

  13. Effect of atmospheric electricity on dry deposition of airborne particles from atmosphere

    NASA Astrophysics Data System (ADS)

    Tammet, H.; Kimmel, V.; Israelsson, S.

    The electric mechanism of dry deposition is well known in the case of unattached radon daughter clusters that are unipolar charged and of high mobility. The problematic role of the electric forces in deposition of aerosol particles is theoretically examined by comparing the fluxes of particles carried by different deposition mechanisms in a model situation. The electric mechanism of deposition appears essential for particles of diameter 10-200 nm in conditions of low wind speed. The electric flux of fine particles can be dominant on the tips of leaves and needles even in a moderate atmospheric electric field of a few hundred V m -1 measured over the plane ground surface. The electric deposition is enhanced under thunderclouds and high voltage power lines. Strong wind suppresses the relative role of the electric deposition when compared with aerodynamic deposition. When compared with diffusion deposition the electric deposition appears less uniform: the precipitation particulate matter on the tips of leaves and especially on needles of top branches of conifer trees is much more intensive than on the ground surface and electrically shielded surfaces of plants. The knowledge of deposition geometry could improve our understanding of air pollution damage to plants.

  14. Size fractionation in mercury-bearing airborne particles (HgPM 10) at Almadén, Spain: Implications for inhalation hazards around old mines

    NASA Astrophysics Data System (ADS)

    Moreno, Teresa; Higueras, Pablo; Jones, Tim; McDonald, Iain; Gibbons, Wes

    Almadén has a >2000y mining history and an unprecedented legacy of mercury contamination. Resuspended airborne particles were extracted from mine waste (Las Cuevas), retort site soil (Almadenejos), and urban car park dust (Almadén), separated into fine (PM 10) and coarse (PM >10 μm ) fractions, analysed for mercury using ICP-MS, and individual HgPM characterised using SEM. Cold extractable mercury concentrations in PM 10 range from 100 to 150 μg g -1 (car parks), to nearly 6000 μg g -1 (mine waste), reaching a world record of 95,000 μg g -1 above the abandoned retort at Almadenejos where ultrafine HgPM have pervaded the brickwork and soil and entered the food chain: edible wild asparagus stem material from here contains 35-65 μg g -1 Hg, and pig hair from animals living, inhaling and ingesting HgPM 10 at the site yielded 8-10 μg g -1. The PM 10 fraction (dusts easily wind transported and deeply inhaled) contains much more mercury than the coarser fraction. The contribution of HgPM 10 to ecosystem contamination and potential human health effects around old mercury mines has been underestimated.

  15. Airborne minerals and related aerosol particles: Effects on climate and the environment

    PubMed Central

    Buseck, Peter R.; Pósfai, Mihály

    1999-01-01

    Aerosol particles are ubiquitous in the troposphere and exert an important influence on global climate and the environment. They affect climate through scattering, transmission, and absorption of radiation as well as by acting as nuclei for cloud formation. A significant fraction of the aerosol particle burden consists of minerals, and most of the remainder— whether natural or anthropogenic—consists of materials that can be studied by the same methods as are used for fine-grained minerals. Our emphasis is on the study and character of the individual particles. Sulfate particles are the main cooling agents among aerosols; we found that in the remote oceanic atmosphere a significant fraction is aggregated with soot, a material that can diminish the cooling effect of sulfate. Our results suggest oxidization of SO2 may have occurred on soot surfaces, implying that even in the remote marine troposphere soot provided nuclei for heterogeneous sulfate formation. Sea salt is the dominant aerosol species (by mass) above the oceans. In addition to being important light scatterers and contributors to cloud condensation nuclei, sea-salt particles also provide large surface areas for heterogeneous atmospheric reactions. Minerals comprise the dominant mass fraction of the atmospheric aerosol burden. As all geologists know, they are a highly heterogeneous mixture. However, among atmospheric scientists they are commonly treated as a fairly uniform group, and one whose interaction with radiation is widely assumed to be unpredictable. Given their abundances, large total surface areas, and reactivities, their role in influencing climate will require increased attention as climate models are refined. PMID:10097046

  16. Heterogeneous reaction of N2O5 with airborne TiO2 particles and the implication for stratospheric particle injection

    NASA Astrophysics Data System (ADS)

    Tang, Mingjin; Abraham, Luke; Braesicke, Peter; Cox, Tony; McGregor, James; Pope, Francis; Pyle, John; Rkiouak, Laylla; Telford, Paul; Watson, Matt; Kalberer, Markus

    2014-05-01

    Injection of aerosol particles (or their precursors) into the stratosphere to scatter solar radiation back into space, has been suggested as a solar-radiation management (SRM) scheme for the mitigation for global warming. TiO2 has recently been highlighted as a possible candidate aerosol because of its high light scattering ability with a refractive index of 2.5 (Pope et al. 2012). The impact of particles injection on stratospheric ozone requires systematical assessment via laboratory and modelling studies. In this work, the heterogeneous reaction of airborne sub-micrometre TiO2 particles with N2O5 has been investigated at room temperature and different relative humidities (RH), using an atmospheric pressure aerosol flow tube. The uptake coefficient of N2O5 onto TiO2, γ(N2O5), was determined to be ~1.0×10-3 at low RH, and increase to ~3×10-3 at 60% RH. The dependence of γ(N2O5) on RH can be explained by the water adsorption isotherm of TiO2 particles. In addition, the uptake of N2O5 onto TiO2 aerosol particles has been included in the UKCA chemistry-climate model to assess the effect of N2O5 uptake onto TiO2 particles on the stratospheric composition. We construct a case study based on the eruption of Mt. Pinatubo, comparing the effects of TiO2 to those from the volcanic sulfate and to the situation with only background amount of aerosol. The changes in reactive nitrogen species and ozone due to the heterogeneous reaction of TiO2 with N2O5 are assessed relative to sulfate aerosol impacts. Pope, F. D., Braesicke, P., Grainger, R. G., Kalberer, M., Watson, I. M., Davidson, P. J., and Cox, R. A.: Stratospheric aerosol particles and solar-radiation management, Nature Clim. Change, 2, 713-719, 2012

  17. Airborne tunable diode laser sensor for high-precision concentration and flux measurements of carbon monoxide and methane

    NASA Technical Reports Server (NTRS)

    Sachse, G. W.; Collins, J. E., Jr.; Hill, G. F.; Wade, L. O.; Burney, L. G.; Ritter, J. A.

    1991-01-01

    An airborne tunable diode laser instrument is described that is capable of operating in two measurement modes. One mode provides high precision (0.1 percent CH4; 1 percent CO) measurements of CH4 and CO with a 5 second response time, and a second mode achieves the very fast response time that is necessary to make airborne eddy correlation flux measurements. Examples of data from atmospheric expeditions of the Global Tropospheric Experiment are presented.

  18. Relationships among particle number, surface area, and respirable mass concentrations in automotive engine manufacturing.

    PubMed

    Heitbrink, William A; Evans, Douglas E; Ku, Bon Ki; Maynard, Andrew D; Slavin, Thomas J; Peters, Thomas M

    2009-01-01

    This study investigated the relationships between particle number, surface area, and respirable mass concentration measured simultaneously in a foundry and an automotive engine machining and assembly center. Aerosol concentrations were measured throughout each plant with a condensation particle counter for number concentration, a diffusion charger for active surface area concentration, and an optical particle counter for respirable mass concentration. At selected locations, particle size distributions were characterized with the optical particle counter and an electrical low pressure impactor. Statistical analyses showed that active surface area concentration was correlated with ultrafine particle number concentration and weakly correlated with respirable mass concentration. Correlation between number and active surface area concentration was stronger during winter (R2 = 0.6 for both plants) than in the summer (R2 = 0.38 and 0.36 for the foundry and engine plant respectively). The stronger correlation in winter was attributed to use of direct-fire gas fired heaters that produced substantial numbers of ultrafine particles with a modal diameter between 0.007 and 0.023 mu m. These correlations support findings obtained through theoretical analysis. Such analysis predicts that active surface area increasingly underestimates geometric surface area with increasing particle size, particularly for particles larger than 100 nm. Thus, a stronger correlation between particle number concentration and active surface area concentration is expected in the presence of high concentrations of ultrafine particles. In general, active surface area concentration may be a concentration metric that is distinct from particle number concentration and respirable mass concentration. For future health effects or toxicological studies involving nano-materials or ultrafine aerosols, this finding needs to be considered, as exposure metrics may influence data interpretation. PMID:18982535

  19. Evaluation of ultraviolet germicidal irradiation in reducing the airborne cultural bacteria concentrations in an elementary school in the Midwestern United States.

    PubMed

    Su, Chunxiao; Lau, Josephine; Gibbs, Shawn G

    2015-05-01

    This article describes a casestudythe authors conducted in an elementary school in the Midwest. The objective was to evaluate the performance of ultraviolet germicidal irradiation (UGVI) to reduce the bioaerosol concentration in a classroom. Two fourth grade classrooms with the same dimensions were studied. One classroom was designated as the UVGI group and the other as the control group. Two-stage Tisch culturable impactors were utilized for collecting airborne bacteria with monthly samples collected from October 2012 to January 2013. Nonparametric methods were applied and p-values smaller than .05 were deemed significant. The concentrations of airborne cultural bacteria with a smaller size (1-8 pm) and the total bacterial concentrations from the UVGI classroom were significantly lower than those of the control room in three of four sampling months. These results could provide the preliminary results necessary to determine the effectiveness of upper-room UVGI in reducing the concentration of airborne cultural bacteria in classrooms and other buildings. PMID:25985534

  20. TOF-SIMS measurements for toxic air pollutants adsorbed on the surface of airborne particles

    NASA Astrophysics Data System (ADS)

    Tomiyasu, Bunbunoshin; Hoshi, Takahiro; Owari, Masanori; Nihei, Yoshimasa

    2003-01-01

    Three kinds of particulate matter were collected: diesel and gasoline exhaust particles emitted directly from exhaust nozzle, and suspended particulate matter (SPM) near the traffic route. Soxhlet extraction was performed on each sample. By gas-chromatograph-mass spectrometer (GC-MS) analysis of these extracts, di-ethyl phthalate and di- n-butyl phthalate were detected from the extract of SPM and diesel exhaust particles (DEPs). Because these phthalates were sometimes suspected as contamination, time-of-flight secondary ion mass spectrometry (TOF-SIMS) measurements were also performed on the samples collected at the same environment. By comparing obtained spectra, it is clear that these environmental endocrine disrupters (EEDs) were adsorbed on DEP surface. Thus, we concluded that the combination of conventional method and TOF-SIMS measurement is one of the most powerful techniques for analyzing the toxic air pollutants adsorbed on SPM surface.

  1. Airborne measurements of new particle formation in the free troposphere above the Mediterranean Sea during the HYMEX campaign

    NASA Astrophysics Data System (ADS)

    Rose, C.; Sellegri, K.; Freney, E.; Dupuy, R.; Colomb, A.; Pichon, J.-M.; Ribeiro, M.; Bourianne, T.; Burnet, F.; Schwarzenboeck, A.

    2015-09-01

    While atmospheric new particle formation (NPF) has been observed in various environments and was found to contribute significantly to the total aerosol particle concentration, the production of new particles over open seas is poorly documented in the literature. Nucleation events were detected and analysed over the Mediterranean Sea using two condensation particle counters and a scanning mobility particle sizer on board the ATR-42 research aircraft during flights conducted between 11 September and 4 November 2012 in the framework of the HYMEX (HYdrological cycle in Mediterranean EXperiment) project. The main purpose of the present work was to characterize the spatial extent of the NPF process, both horizontally and vertically. Our findings show that nucleation is occurring over large areas above the Mediterranean Sea in all air mass types. Maximum concentrations of particles in the size range 5-10 nm (N5-10) do not systematically coincide with lower fetches (time spent by the air mass over the sea before sampling), and significant N5-10 values are found for fetches between 0 and 60 h depending on the air mass type. These observations suggest that nucleation events could be more influenced by local precursors originating from emission processes occurring above the sea, rather than linked to synoptic history. Vertical soundings were performed, giving the opportunity to examine profiles of the N5-10 concentration and to analyse the vertical extent of NPF. Our observations demonstrate that the process could be favoured above 1000 m, i.e. frequently in the free troposphere, and more especially between 2000 and 3000 m, where the NPF frequency is close to 50 %. This vertical distribution of NPF might be favoured by the gradients of several atmospheric parameters, together with the mixing of two air parcels, which could also explain the occurrence of the process at preferential altitudes. In addition, increased condensation sinks collocated with high concentrations of

  2. TRENDS OF POLYCYCLIC AROMATIC HYDROCARBON LEVELS AND MUTAGENICITY IN SANTIAGO'S INHALABLE AIRBORNE PARTICLES IN THE PERIOD 1992-1996.

    EPA Science Inventory

    Abstract

    Trends of polycyclic aromatic hydrocarbons (PAHs) for 1992-1996 (cold season) and their mutagenic activity were investigated in organic extracts from the Santiago. Chile. inhalable particles (PM10). The highest PAH concentrations were observed in 1992 and decline...

  3. Mutagenicity of fine airborne particles: diurnal variation in community air determined by a Salmonella micro preincubation (microsuspension) procedure

    SciTech Connect

    Kado, N.Y.; Guirguis, G.N.; Flessel, C.P.; Chan, R.C.; Chang, K.I.; Wesolowski, J.J.

    1986-01-01

    A simple modification of the Salmonella liquid incubation assay previously developed for detecting mutagens in urine was used to determine mutagenic activity of airborne particulate matter. The modification consists of adding ten times more bacteria and five to ten times less metabolic enzymes compared to the plate incorporation method. The mixture volume is approximately 0.2 ml, and the mixture is incubated for 90 min before pouring it according to the standard protocol. The modified procedure was approximately ten times more sensitive than the standard plate incorporation test for detecting mutagens in air particulate extracts and approximately ten to 31 times more sensitive for the chemical mutagens 2-nitrofluorene, 4-nitroquinoline-N-oxide, 2-aminofluorene, and benzo(a)pyrene in bacterial strain TA98. Mutagenic activity was associated exclusively with fine particles (aerodynamic diameters of less than 2.5 ..mu..m). Diurnal patterns of mutagenic activity were investigated by measuring filter extracts from 2-hr samples collected in three San Francisco Bay Area cities during the summer or fall of 1982. Four criteria pollutants - lead, nitrogen dioxide, ozone, and sulfur dioxide - were simultaneously sampled at one location.

  4. Use of micro-XANES to speciate chromium in airborne fine particles in the Sacramento Valley

    SciTech Connect

    Michelle L. Werner; Peter S. Nico; Matthew A. Marcus; Cort Anastasio

    2007-07-15

    While particulate matter (PM) in the atmosphere can lead to a wide array of negative health effects, the cause of toxicity is largely unknown. One aspect of PM that likely affects health is the chemical composition, in particular the transition metals within the particles. Chromium is one transition metal of interest due to its two major oxidation states, with Cr(III) being much less toxic compared to Cr(VI). Using microfocused X-ray absorption near edge structure (micro-XANES), we analyzed the Cr speciation in fine particles (diameters {le} 2.5 {mu}m) collected at three sites in the Sacramento Valley of northern California: Sacramento, a large urban area, Davis, a small city, and Placerville, a rural area. These are several major stationary sources of Cr within 24 km of the site including chrome-plating plants, power plants and incinerators. The microfocused X-ray beam enables us to look at very small areas on the filter with a resolution of typically 5-7 micrometers. With XANES we are able to not only distinguish between Cr(VI) and Cr(III), but also to identify different types of Cr(III) and more reduced Cr species. At all of our sampling sites the main Cr species were Cr(III), with Cr(OH){sub 3} or a Cr-Fe, chromite-like, phase being the dominant species. Cr(VI)-containing particles were found only in the most urban site. All three sites contained some reduced Cr species, either Cr(0) or Cr{sub 3}C{sub 2}, although these were minor components. This work demonstrates that micro-XANES can be used as a minimally invasive analytical tool to investigate the composition of ambient PM. 32 refs., 6 figs.

  5. 290 and 340 nm UV LED arrays for fluorescence detection from single airborne particles

    NASA Astrophysics Data System (ADS)

    Davitt, Kristina; Song, Yoon-Kyu; Patterson, William R., III; Nurmikko, Arto V.; Gherasimova, Maria; Han, Jung; Pan, Yong-Le; Chang, Richard K.

    2005-11-01

    We demonstrate a compact system, incorporating a 32-element linear array of ultraviolet (290 nm and 340 nm) light-emitting diodes (LEDs) and a multi-anode photomultiplier tube, to the in-flight fluorescence detection of aerosolized particles, here containing the biological molecules tryptophan and NADH. This system illustrates substantial advances in the growth and fabrication of new semiconductor UV light emitting devices and an evolution in packaging details for LEDs tailored to the bio-aerosol warning problem. Optical engineering strategies are employed which take advantage of the size and versatility of light-emitting diodes to develop a truly compact fluorescence detector.

  6. 290 and 340 nm UV LED arrays for fluorescence detection from single airborne particles.

    PubMed

    Davitt, Kristina; Song, Yoon-Kyu; Patterson Iii, William; Nurmikko, Arto; Gherasimova, Maria; Han, Jung; Pan, Yong-Le; Chang, Richard

    2005-11-14

    We demonstrate a compact system, incorporating a 32-element linear array of ultraviolet (290 nm and 340 nm) light-emitting diodes (LEDs) and a multi-anode photomultiplier tube, to the in-flight fluorescence detection of aerosolized particles, here containing the biological molecules tryptophan and NADH. This system illustrates substantial advances in the growth and fabrication of new semiconductor UV light emitting devices and an evolution in packaging details for LEDs tailored to the bio-aerosol warning problem. Optical engineering strategies are employed which take advantage of the size and versatility of light-emitting diodes to develop a truly compact fluorescence detector. PMID:19503158

  7. Characterization of concentration, particle size distribution, and contributing factors to ambient hexavalent chromium in an area with multiple emission sources

    NASA Astrophysics Data System (ADS)

    Yu, Chang Ho; Huang, Lihui; Shin, Jin Young; Artigas, Francisco; Fan, Zhi-hua (Tina)

    2014-09-01

    Airborne hexavalent chromium (Cr(VI)) is a known pulmonary carcinogen and can be emitted from both natural and anthropogenic sources, including diesel emissions. However, there is limited knowledge about ambient Cr(VI) concentration levels and its particle size distribution. This pilot study characterized ambient Cr(VI) concentrations in the New Jersey Meadowlands (NJ ML) district, which is close to the heavily trafficked New Jersey Turnpike (NJTPK) as well as Chromium Ore Processing Residue (COPR) waste sites. Monitoring was simultaneously conducted at two sites, William site (∼50 m from NJTPK) and MERI site (∼700 m from NJTPK). The distance between the two sites is approximately 6.2 km. Ambient Cr(VI) concentrations and PM2.5 mass concentrations were concurrently measured at both sites during summer and winter. The summer concentrations (mean ± S.D. [median]), 0.13 ± 0.06 [0.12] ng/m3 at the MERI site and 0.08 ± 0.05 [0.07] ng/m3 at the William site, were all significantly higher than the winter concentrations, 0.02 ± 0.01 [0.02] ng/m3 and 0.03 ± 0.01 [0.03] ng/m3 at the MERI and William sites, respectively. The site difference (i.e., MERI > William) was observed for summer Cr(VI) concentrations; however, no differences for winter and pooled datasets. These results suggest higher Cr(VI) concentrations may be attributed from stronger atmospheric reactions such as photo-oxidation of Cr(III) to Cr(VI) in the summer. The Cr(VI) distribution as a function of particle size, ranging from 0.18 to 18 μm, was determined at the William site. It was found that Cr(VI) was enriched in the particles less than 2.5 μm in diameter (PM2.5). This finding suggested potential health concerns, because PM2.5 are easily inhaled and deposited in the alveoli. A multiple linear regression analysis confirmed ambient Cr(VI) concentrations were significantly affected by meteorological factors (i.e., temperature and humidity) and reactive gases/particles (i.e., O3, Fe and Mn).

  8. Characterization of concentration, particle size distribution, and contributing factors to ambient hexavalent chromium in an area with multiple emission sources

    PubMed Central

    Yu, Chang Ho; Huang, Lihui; Shin, Jin Young; Artigas, Francisco; Fan, Zhi-hua (Tina)

    2015-01-01

    Airborne hexavalent chromium (Cr(VI)) is a known pulmonary carcinogen and can be emitted from both natural and anthropogenic sources, including diesel emissions. However, there is limited knowledge about ambient Cr(VI) concentration levels and its particle size distribution. This pilot study characterized ambient Cr(VI) concentrations in the New Jersey Meadowlands (NJ ML) district, which is close to the heavily trafficked New Jersey Turnpike (NJTPK) as well as Chromium Ore Processing Residue (COPR) waste sites. Monitoring was simultaneously conducted at two sites, William site (~50 m from NJTPK) and MERI site (~700 m from NJTPK). The distance between the two sites is approximately 6.2 km. Ambient Cr(VI) concentrations and PM2.5 mass concentrations were concurrently measured at both sites during summer and winter. The summer concentrations (mean ± S.D. [median]), 0.13 ± 0.06 [0.12] ng/m3 at the MERI site and 0.08 ± 0.05 [0.07] ng/m3 at the William site, were all significantly higher than the winter concentrations, 0.02 ± 0.01 [0.02] ng/m3 and 0.03 ± 0.01 [0.03] ng/m3 at the MERI and William sites, respectively. The site difference (i.e., MERI > William) was observed for summer Cr(VI) concentrations; however, no differences for winter and pooled datasets. These results suggest higher Cr(VI) concentrations may be attributed from stronger atmospheric reactions such as photo-oxidation of Cr(III) to Cr(VI) in the summer. The Cr(VI) distribution as a function of particle size, ranging from 0.18 to 18 μm, was determined at the William site. It was found that Cr(VI) was enriched in the particles less than 2.5 μm in diameter (PM2.5). This finding suggested potential health concerns, because PM2.5 are easily inhaled and deposited in the alveoli. A multiple linear regression analysis confirmed ambient Cr(VI) concentrations were significantly affected by meteorological factors (i.e., temperature and humidity) and reactive gases/particles (i.e., O3, Fe and Mn). PMID

  9. Characteristics of mass concentrations depending on synoptic features during airborne dustfall episodes observed at Cheongwon in Korea in 2005

    NASA Astrophysics Data System (ADS)

    Kim, Hak-Sung; Chung, Yong-Seung

    2010-05-01

    Sandstorms in the desert and loess regions of north China and Mongolia, as well as the associated dustfall episodes on the Korean Peninsula, were monitored in 2005. The ground mass concentrations of PM10 and PM2.5 were analyzed during dustfall episodes at Cheongwon, in central south Korea, based on synoptic features at surface, 850 hPa and 500 hPa levels. A total of seven dustfall episodes lasting eleven days were observed and the mass concentration ratios of PM2.5 and PM10 during dustfall episodes were classified into a severe dustfall episode (SDE) and a moderate dustfall episode (MDE) depending upon two synoptic features. The main synoptic feature was for SDEs, which occurred frequently under a surface anticyclone and cyclone located in the west and east of the Korean Peninsula with large amplitude trough at 500 hPa over the northern Korean Peninsula. The sandstorms at the source headed directly to Korea via a strong N-NW wind without passing through any large cities or industrial areas of east China. The PM10 mass concentration sharply increased during the SDEs; however, the fine aerosol fraction of PM2.5 levels was relatively low with 13.6% of the mass concentration. In a synoptic feature for MDEs, a slow moving cyclone headed to Korea via the industrial areas of northeastern China under a small amplitude trough at a 500 hPa level. A weak anticyclone was also located over China. MDEs showed low mass concentrations of coarse PM10 particles and large fraction of fine PM2.5 particles at 46.3%.

  10. Airborne particulate matter and human health: toxicological assessment and importance of size and composition of particles for oxidative damage and carcinogenic mechanisms.

    PubMed

    Valavanidis, Athanasios; Fiotakis, Konstantinos; Vlachogianni, Thomais

    2008-01-01

    Air pollution has been considered a hazard to human health. In the past decades, many studies highlighted the role of ambient airborne particulate matter (PM) as an important environmental pollutant for many different cardiopulmonary diseases and lung cancer. Numerous epidemiological studies in the past 30 years found a strong exposure-response relationship between PM for short-term effects (premature mortality, hospital admissions) and long-term or cumulative health effects (morbidity, lung cancer, cardiovascular and cardiopulmonary diseases, etc). Current research on airborne particle-induced health effects investigates the critical characteristics of particulate matter that determine their biological effects. Several independent groups of investigators have shown that the size of the airborne particles and their surface area determine the potential to elicit inflammatory injury, oxidative damage, and other biological effects. These effects are stronger for fine and ultrafine particles because they can penetrate deeper into the airways of the respiratory tract and can reach the alveoli in which 50% are retained in the lung parenchyma. Composition of the PM varies greatly and depends on many factors. The major components of PM are transition metals, ions (sulfate, nitrate), organic compound, quinoid stable radicals of carbonaceous material, minerals, reactive gases, and materials of biologic origin. Results from toxicological research have shown that PM have several mechanisms of adverse cellular effects, such as cytotoxicity through oxidative stress mechanisms, oxygen-free radical-generating activity, DNA oxidative damage, mutagenicity, and stimulation of proinflammatory factors. In this review, the results of the most recent epidemiological and toxicological studies are summarized. In general, the evaluation of most of these studies shows that the smaller the size of PM the higher the toxicity through mechanisms of oxidative stress and inflammation. Some studies

  11. HUMAN CLINICAL STUDIES OF CONCENTRATED AMBIENT ULTRAFINE AND FINE PARTICLES

    EPA Science Inventory

    Confirmation of our hypothesis that exposure to ambient ultrafine and fine particles promotes coagulation and alters cardiac function will have important implications for air pollution regulatory efforts, and will provide new approaches for the prevention of cardiovascular hea...

  12. Study on size distributions of airborne particles by aircraft observation in spring over eastern coastal areas of China

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Liu, Hongjie; Yue, Xin; Li, Hong; Chen, Jianhua; Tang, Dagang

    2005-06-01

    The authors studied the size distributions of particles at an altitude of 2000 m by aircraft observation over eastern costal areas of China from Zhuhai, Guangdong to Dalian, Liaoning (0.47 30 μm, 57 channels, including number concentration distribution, surface area concentration distribution and mass concentration distribution). In these cities, the average daily concentrations of PM10 are very high. They are among the most heavily polluted cities in China. The main pollution sources are anthropogenic activities such as wood, coal and oil burning. The observed size distributions show a broad spectrum and unique multi-peak characteristics, indicating no significant impacts of individual sources from urban areas. These results are far different from the distribution type at ground level. It may reflect the comprehensive effect of the regional pollution characteristics. Monitoring results over big cities could to some extent reflect their pollution characteristics.

  13. Study of chemical composition and morphology of airborne particles in Chandigarh, India using EDXRF and SEM techniques.

    PubMed

    Sharma, S G; Srinivas, M S N

    2009-03-01

    The elemental composition and morphology of aerosols, collected from March 95 to February 96 and March 96 to August 96 respectively in the city of Chandigarh, India is determined using Energy Dispersive X-ray fluorescence and scanning electron microscopic techniques. The elemental concentration levels are found to be higher by a factor of 2-7 in the spring season as compared to the rainy season. The concentration of spherical and non-spherical (i.e. elongated) aerosols is more in the spring season and is reduced drastically in the rainy season due to the prominent wash out effect of rains. More accurate particle classification and source identification is obtained when based on combination of chemical composition and particle morphology. Possible sources identified from this analysis are soil dust, Industrial activity, Agricultural and Garbage burning, Maritime aerosols and Automobile exhaust. PMID:18418721

  14. Acute health impacts of airborne particles estimated from satellite remote sensing.

    PubMed

    Wang, Zhaoxi; Liu, Yang; Hu, Mu; Pan, Xiaochuan; Shi, Jing; Chen, Feng; He, Kebin; Koutrakis, Petros; Christiani, David C

    2013-01-01

    Satellite-based remote sensing provides a unique opportunity to monitor air quality from space at global, continental, national and regional scales. Most current research focused on developing empirical models using ground measurements of the ambient particulate. However, the application of satellite-based exposure assessment in environmental health is still limited, especially for acute effects, because the development of satellite PM(2.5) model depends on the availability of ground measurements. We tested the hypothesis that MODIS AOD (aerosol optical depth) exposure estimates, obtained from NASA satellites, are directly associated with daily health outcomes. Three independent healthcare databases were used: unscheduled outpatient visits, hospital admissions, and mortality collected in Beijing metropolitan area, China during 2006. We use generalized linear models to compare the short-term effects of air pollution assessed by ground monitoring (PM(10)) with adjustment of absolute humidity (AH) and AH-calibrated AOD. Across all databases we found that both AH-calibrated AOD and PM(10) (adjusted by AH) were consistently associated with elevated daily events on the current day and/or lag days for cardiovascular diseases, ischemic heart diseases, and COPD. The relative risks estimated by AH-calibrated AOD and PM(10) (adjusted by AH) were similar. Additionally, compared to ground PM(10), we found that AH-calibrated AOD had narrower confidence intervals for all models and was more robust in estimating the current day and lag day effects. Our preliminary findings suggested that, with proper adjustment of meteorological factors, satellite AOD can be used directly to estimate the acute health impacts of ambient particles without prior calibrating to the sparse ground monitoring networks. PMID:23220016

  15. Acute health impacts of airborne particles estimated from satellite remote sensing✩

    PubMed Central

    Wang, Zhaoxi; Liu, Yang; Hu, Mu; Pan, Xiaochuan; Shi, Jing; Chen, Feng; He, Kebin; Koutrakis, Petros; Christiani, David C.

    2013-01-01

    Satellite-based remote sensing provides a unique opportunity to monitor air quality from space at global, continental, national and regional scales. Most current research focused on developing empirical models using ground measurements of the ambient particulate. However, the application of satellite-based exposure assessment in environmental health is still limited, especially for acute effects, because the development of satellite PM2.5 model depends on the availability of ground measurements. We tested the hypothesis that MODIS AOD (aerosol optical depth) exposure estimates, obtained from NASA satellites, are directly associated with daily health outcomes. Three independent healthcare databases were used: unscheduled outpatient visits, hospital admissions, and mortality collected in Beijing metropolitan area, China during 2006. We use generalized linear models to compare the short-term effects of air pollution assessed by ground monitoring (PM10) with adjustment of absolute humidity (AH) and AH-calibrated AOD. Across all databases we found that both AH-calibrated AOD and PM10 (adjusted by AH) were consistently associated with elevated daily events on the current day and/or lag days for cardiovascular diseases, ischemic heart diseases, and COPD. The relative risks estimated by AH-calibrated AOD and PM10 (adjusted by AH) were similar. Additionally, compared to ground PM10, we found that AH-calibrated AOD had narrower confidence intervals for all models and was more robust in estimating the current day and lag day effects. Our preliminary findings suggested that, with proper adjustment of meteorological factors, satellite AOD can be used directly to estimate the acute health impacts of ambient particles without prior calibrating to the sparse ground monitoring networks. PMID:23220016

  16. Factors affecting the concentration of outdoor particles indoors (COPI): Identification of data needs and existing data

    SciTech Connect

    Thatcher, Tracy L.; McKone, Thomas E.; Fisk, William J.; Sohn, Michael D.; Delp, Woody W.; Riley, William J.; Sextro, Richard G.

    2001-12-01

    The process of characterizing human exposure to particulate matter requires information on both particle concentrations in microenvironments and the time-specific activity budgets of individuals among these microenvironments. Because the average amount of time spent indoors by individuals in the US is estimated to be greater than 75%, accurate characterization of particle concentrations indoors is critical to exposure assessments for the US population. In addition, it is estimated that indoor particle concentrations depend strongly on outdoor concentrations. The spatial and temporal variations of indoor particle concentrations as well as the factors that affect these variations are important to health scientists. For them, knowledge of the factors that control the relationship of indoor particle concentrations to outdoor levels is particularly important. In this report, we identify and evaluate sources of data for those factors that affect the transport to and concentration of outdoor particles in the indoor environment. Concentrations of particles indoors depend upon the fraction of outdoor particles that penetrate through the building shell or are transported via the air handling (HVAC) system, the generation of particles by indoor sources, and the loss mechanisms that occur indoors, such as deposition. To address these issues, we (i) identify and assemble relevant information including the behavior of particles during air leakage, HVAC operations, and particle filtration; (ii) review and evaluate the assembled information to distinguish data that are directly relevant to specific estimates of particle transport from those that are only indirectly useful and (iii) provide a synthesis of the currently available information on building air-leakage parameters and their effect on indoor particle matter concentrations.

  17. A method based on light scattering to estimate the concentration of virus particles without the need for virus particle standards☆

    PubMed Central

    Makra, István; Terejánszky, Péter; Gyurcsányi, Róbert E.

    2015-01-01

    Most often the determination of the concentration of virus particles is rendered difficult by the availability of proper standards. We have adapted a static light scattering based method for the quantification of virus particles (shown for poliovirus) without the need of virus particle standards. Instead, as standards, well-characterized polymeric nanoparticle solutions are used. The method is applicable for virus particles acting as Rayleigh scatterers, i.e., virus particles with equivalent diameters up to ca. 1/10th of the wavelength of the scattered monochromatic light (∼70 nm diameter). Further limitations may arise if the refractive index of the virus is unavailable or cannot be calculated based on its composition, such as in case of enveloped viruses. The method is especially relevant for preparation of virus particle concentration standards and to vaccine formulations based on attenuated or inactivated virus particles where the classical plaque forming assays cannot be applied. The method consists of: • Measuring the intensity of the light scattered by viruses suspended in an aqueous solution. • Measuring the intensity of the light scattered by polymeric nanoparticles of known concentration and comparable size with the investigated virus particle. • The concentration of virus nanoparticles can be calculated based on the two measured scattered light intensities by knowing the refractive index of the dispersing solution, of the polymer and virus nanoparticles as well as their relative sphere equivalent diameters. PMID:26150976

  18. A method based on light scattering to estimate the concentration of virus particles without the need for virus particle standards.

    PubMed

    Makra, István; Terejánszky, Péter; Gyurcsányi, Róbert E

    2015-01-01

    Most often the determination of the concentration of virus particles is rendered difficult by the availability of proper standards. We have adapted a static light scattering based method for the quantification of virus particles (shown for poliovirus) without the need of virus particle standards. Instead, as standards, well-characterized polymeric nanoparticle solutions are used. The method is applicable for virus particles acting as Rayleigh scatterers, i.e., virus particles with equivalent diameters up to ca. 1/10th of the wavelength of the scattered monochromatic light (∼70 nm diameter). Further limitations may arise if the refractive index of the virus is unavailable or cannot be calculated based on its composition, such as in case of enveloped viruses. The method is especially relevant for preparation of virus particle concentration standards and to vaccine formulations based on attenuated or inactivated virus particles where the classical plaque forming assays cannot be applied. The method consists of: •Measuring the intensity of the light scattered by viruses suspended in an aqueous solution.•Measuring the intensity of the light scattered by polymeric nanoparticles of known concentration and comparable size with the investigated virus particle.•The concentration of virus nanoparticles can be calculated based on the two measured scattered light intensities by knowing the refractive index of the dispersing solution, of the polymer and virus nanoparticles as well as their relative sphere equivalent diameters. PMID:26150976

  19. [Variation of atmospheric particle number concentrations in Qingdao and its impact on visibility].

    PubMed

    Ke, Xin-Shu; Sheng, Li-Fang; Kong, Jun; Hao, Ze-Tong; Qu, Wen-Jun

    2014-01-01

    Atmospheric particle number concentrations were measured from September 2010 to August 2011 with potable light house laser particle counter to study the variation of atmospheric particle concentrations and its impact on visibility in Qingdao. Backward trajectory was calculated by Hysplit model. Statistical analysis was done to discuss the influence of meteorological factors on the atmospheric particle number concentrations and visibility. It was shown that the atmospheric particle number concentrations were the highest in winter and spring, followed by autumn, and the lowest in summer. Air mass from Xinjiang and Gansu regions resulted in higher particle concentrations, while the atmospheric particles from the northeast and the ocean had lower concentrations. The variation of atmospheric particle number concentrations presented a good negative correlation with the variation of wind speed, relative humidity and mixed-layer height. When the air mass came from west or northwest, the surface wind direction was south or southeast and the mixed-layer height was low, the number concentration of fine particles was likely to be higher, which tended to cause low visibility phenomenon. PMID:24720179

  20. Method of particle trajectory recognition in particle flows of high particle concentration using a candidate trajectory tree process with variable search areas

    DOEpatents

    Shaffer, Franklin D.

    2013-03-12

    The application relates to particle trajectory recognition from a Centroid Population comprised of Centroids having an (x, y, t) or (x, y, f) coordinate. The method is applicable to visualization and measurement of particle flow fields of high particle. In one embodiment, the centroids are generated from particle images recorded on camera frames. The application encompasses digital computer systems and distribution mediums implementing the method disclosed and is particularly applicable to recognizing trajectories of particles in particle flows of high particle concentration. The method accomplishes trajectory recognition by forming Candidate Trajectory Trees and repeated searches at varying Search Velocities, such that initial search areas are set to a minimum size in order to recognize only the slowest, least accelerating particles which produce higher local concentrations. When a trajectory is recognized, the centroids in that trajectory are removed from consideration in future searches.

  1. Retrieval of Atmospheric CO2 Concentration above Clouds and Cloud Top Pressure from Airborne Lidar Measurements during ASCENDS Science Campaigns

    NASA Astrophysics Data System (ADS)

    Mao, J.; Ramanathan, A. K.; Rodriguez, M.; Allan, G. R.; Hasselbrack, W. E.; Abshire, J. B.; Riris, H.; Kawa, S. R.

    2014-12-01

    NASA Goddard is developing an integrated-path, differential absorption (IPDA) lidar approach to measure atmospheric CO2 concentrations from space as a candidate for NASA's ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons) mission. The approach uses pulsed lasers to measure both CO2 and O2 absorption simultaneously in the vertical path to the surface at a number of wavelengths across a CO2 line at 1572.335 nm and an O2 line doublet near 764.7 nm. Measurements of time-resolved laser backscatter profiles from the atmosphere allow the technique to estimate column CO2 and O2 number density and range to cloud tops in addition to those to the ground. This allows retrievals of CO2 column above clouds and cloud top pressure, and all-sky measurement capability from space. This additional information can be used to evaluate atmospheric transport processes and other remote sensing carbon data in the free atmosphere, improve carbon data assimilation in models and help global and regional carbon flux estimates. We show some preliminary results of this capability using airborne lidar measurements from the summers of 2011 and 2014 ASCENDS science campaigns. These show simultaneous retrievals of CO2 and O2 column densities for laser returns from low-level marine stratus clouds in the west coast of California. This demonstrates the supplemental capability of the future space carbon mission to measure CO2 above clouds, which is valuable particularly for the areas with persistent cloud covers, e.g, tropical ITCZ, west coasts of continents with marine layered clouds and southern ocean with highest occurrence of low-level clouds, where underneath carbon cycles are active but passive remote sensing techniques using the reflected short wave sunlight are unable to measure accurately due to cloud scattering effect. We exercise cloud top pressure retrieval from O2 absorption measurements during the flights over the low-level marine stratus cloud decks, which is one of

  2. Airborne in-situ investigations of the Eyjafjallajökull volcanic ash plume on Iceland and over north-western Germany with light aircrafts and optical particle counters

    NASA Astrophysics Data System (ADS)

    Weber, K.; Eliasson, J.; Vogel, A.; Fischer, C.; Pohl, T.; van Haren, G.; Meier, M.; Grobéty, B.; Dahmann, D.

    2012-03-01

    During the time period of the eruption of the Icelandic volcano Eyjafjallajökull in April/May 2010 the Duesseldorf University of Applied Sciences has performed 14 research flights in situations with and without the volcanic ash plume over Germany. In parallel to the research flights in Germany three measurement flights have been performed by the University of Iceland in May 2010 over the western part of Iceland. During two of these flights the outskirts of the eruption plume were entered directly, delivering most direct measurements within the eruption plume during this eruptive event. For all the measurement flights reported here, light durable piston-motor driven aircrafts were used, which were equipped with optical particle counters for in-situ measurements. Real-time monitoring of the particle concentrations was possible during the flights. As different types of optical particle counters have been used in Iceland and Germany, the optical particle counters have been re-calibrated after the flights to the same standard using gravimetric reference methods and original Eyjafjallajökull volcanic ash samples. In-situ measurement results with high spatial resolution, directly from the eruption plume in Iceland as well as from the dispersed and several days old plume over Germany, are therefore presented here for the first time. They are normalized to the same ash concentration calibration standard. Moreover, airborne particles could be sampled directly out of the eruption plume in Iceland as well as during the flights over Germany. During the research flights over Iceland from 9 May 2011 to 11 May 2011 the ash emitted from the vent of the volcano turned out to be concentrated in a narrow well-defined plume of about 10 km width at a distance of 45-60 km away from the vent. Outside this plume the airborne ash concentrations could be proved to be below 50 μg m -3 over western Iceland. However, by entering the outskirts of the plume directly the research aircraft could

  3. Concentrations of trace elements and compounds in the airborne suspended particulate matter in Cleveland, Ohio, from August 1971 to August 1972 and their dependence on wind direction: Complete data listing and concentration roses

    NASA Technical Reports Server (NTRS)

    King, R. B.; Neustadter, H. E.

    1976-01-01

    Concentrations of 75 chemical constituents in the airborne particulate matter were measured in Cleveland, Ohio during 1971 and 1972. Daily values, maxima, geometric means and their standard deviations covering a 1-year period (45 to 50 sampling days) at each of 16 sites are presented on microfiche for 60 elements, and for a lesser number of days for 10 polycyclic aromatic hydrocarbon compounds (PAH), the aliphatic hydrocarbon compounds (AH) as a group and carbon. In addition, concentration roses showing directional properties are presented for 39 elements, 10 PAH and the AH as a group. The elements (except carbon) are shown both in terms of concentration and percentage of the suspended particulate matter.

  4. Control of airborne fungal spores in a university hospital

    SciTech Connect

    Streifel, A.J.; Vesley, D. ); Rhame, F.S. ); Murray, B. )

    1989-01-01

    A new university hospital was designed to maximize the air quality protection of severely compromised patients undergoing transplantation or treatment for malignant disorders. The entire hospital was designed as a sealed building with two filter systems having >95% efficiencies for 1.0 {mu}m particles. Controlled airflow and isolation of the most severely compromised patients were also design features. Air quality monitoring of particles and airborne fungi demonstrate effective control in the patient environment. The results show the areas with the greatest control of personnel and air changes have the lowest airborne concentrations of fungi and the smallest particles. Larger indoor airborne particle ranking indicate highest levels depending on local human activity, air changes rates, or filtration efficiency.

  5. COOKING-RELATED PARTICLE CONCENTRATIONS MEASURED IN AN OCCUPIED TOWNHOME IN RESTON, VA

    EPA Science Inventory

    In non-smoking households, cooking is one of the most significant sources of indoor particles. To date, there are limited data available regarding indoor particle concentrations generated by different types of cooking. To increase the knowledge base associated with particles ...

  6. PARTICLE ASSOCIATION EFFECTS ON MICROBIAL INDICATOR CONCENTRATIONS AND CSO DISINFECTION

    EPA Science Inventory

    Combined sewer overflow (CSO) and wastewater disinfection effectiveness are evaluated by measuring microbial indicator concentrations before and after disinfection. The standard techniques for quantifying indicators are membrane filtration and multiple-tube fermentation/most pro...

  7. CONTROLLED EXPOSURES OF HEALTHY AND ASTHMATIC VOLUNTEERS TO CONCENTRATED AMBIENT PARTICLES IN METROPOLITAN LOS ANGELES

    EPA Science Inventory

    Investigators expect to use a Harvard ambient particle concentrator to assess the effects of exposure to concentrated ambient particles (CAPs) on healthy and asthmatic people.  12 healthy individuals and 12 individuals with mild asthma will be exposed to either filtere...

  8. CONCENTRATED AMBIENT AIR PARTICLES INDUCE PULMONARY INFLAMMATION IN HEALTHY HUMAN VOLUNTEERS

    EPA Science Inventory


    We tested the hypothesis that exposure of healthy volunteers to concentrated ambient particles (CAPS) is associated with an influx of inflammatory cells into the lower respiratory tract. Thirty-eight volunteers were exposed to either filtered air or particles concentrated fro...

  9. Apparatus and method for collection and concentration of respirable particles into a small fluid volume

    DOEpatents

    Simon, Jonathan N.; Brown, Steve B.

    2002-01-01

    An apparatus and method for the collection of respirable particles and concentration of such particles into a small fluid volume. The apparatus captures and concentrates small (1-10 .mu.m) respirable particles into a sub-millileter volume of fluid. The method involves a two step operation, collection and concentration: wherein collection of particles is by a wetted surface having small vertical slits that act as capillary channels; and concentration is carried out by transfer of the collected particles to a small volume (sub-milliliter) container by centrifugal force whereby the particles are forced through the vertical slits and contact a non-wetted wall surface, and are deflected to the bottom where they are contained for analysis, such as a portable flow cytometer or a portable PCR DNA analysis system.

  10. Characterization of ultrafine particle number concentration and new particle formation in an urban environment of Taipei, Taiwan

    NASA Astrophysics Data System (ADS)

    Cheung, H. C.; Chou, C. C.-K.; Huang, W.-R.; Tsai, C.-Y.

    2013-09-01

    An intensive aerosol characterization experiment was performed at the Taipei Aerosol and Radiation Observatory (TARO, 25.02° N, 121.53° E) in the urban area of Taipei, Taiwan, during July 2012. Number concentration and size distribution of aerosol particles were measured continuously, which were accompanied by concurrent measurements of mass concentration of submicron particles, PM1 (d ≤ 1 μm), and photolysis rate of ozone, J(O1D). The averaged number concentrations of total (Ntotal), accumulation mode (Nacu), Aitken mode (NAitken), and nucleation mode (Nnuc) particles were 13.9 × 103 cm-3, 1.2 × 103 cm-3, 6.1 × 103 cm-3, and 6.6 × 103 cm-3, respectively. Accordingly, the ultrafine particles (UFPs, d ≤ 100 nm) accounted for 91% of the total number concentration of particles measured in this study (10 ≤ d ≤ 429 nm), indicating the importance of UFPs to the air quality and radiation budget in Taipei and its surrounding areas. An averaged Nnuc / NOx ratio of 192.4 cm-3 ppbv-1 was derived from nighttime measurements, which was suggested to be the characteristic of vehicle emissions that contributed to the "urban background" of nucleation mode particles throughout a day. On the contrary, it was found that the number concentration of nucleation mode particles was independent of NOx and could be elevated up to 10 times of the "urban background" levels during daytime, suggesting a substantial amount of nucleation mode particles produced from photochemical processes. Averages (± 1σ) of the diameter growth rate (GR) and formation rate of nucleation mode particles, J10, were 11.9 ± 10.6 nm h-1 and 6.9 ± 3.0 cm-3 s-1, respectively. Consistency in the time series of the nucleation mode particle concentration and the proxy of H2SO4 production, UVB · SO2/CS, for new particle formation (NPF) events suggested that photooxidation of SO2 was likely one of the major mechanisms for the formation of new particles in our study area. Moreover, it was revealed that the

  11. Concentrations of ultrafine particles at a highway toll collection booth and exposure implications for toll collectors.

    PubMed

    Cheng, Yu-Hsiang; Huang, Cheng-Hsiung; Huang, Hsiao-Lin; Tsai, Chuen-Jinn

    2010-12-15

    Research regarding the magnitude of ultrafine particle levels at highway toll stations is limited. This study measured ambient concentrations of ultrafine particles at a highway toll station from October 30 to November 1 and November 5 to November 6, 2008. A scanning mobility particle sizer was used to measure ultrafine particle concentrations at a ticket/cash tollbooth. Levels of hourly average ultrafine particles at the tollbooth were about 3-6 times higher than those in urban backgrounds, indicating that a considerable amount of ultrafine particles are exhausted from passing vehicles. A bi-modal size distribution pattern with a dominant mode at about <6 nm and a minor mode at about 40 nm was observed at the tollbooth. The high amounts of nanoparticles in this study can be attributed to gas-to-particle reactions in fresh fumes emitted directly from vehicles. The influences of traffic volume, wind speed, and relative humidity on ultrafine particle concentrations were also determined. High ambient concentrations of ultrafine particles existed under low wind speed, low relative humidity, and high traffic volume. Although different factors account for high ambient concentrations of ultrafine particles at the tollbooth, measurements indicate that toll collectors who work close to traffic emission sources have a high exposure risk. PMID:21071066

  12. Airborne and ground-based measurements of the trace gases and particles emitted from prescribed fires in the United States

    SciTech Connect

    Burling, Ian; Yokelson, Robert J.; Akagi, Sheryl; Urbanski, Shawn; Wold, Cyle E.; Griffith, David WT; Johnson, Timothy J.; Reardon, James; Weise, David

    2011-12-07

    We measured the emission factors for 19 trace gas species and particulate matter (PM2.5) from 14 prescribed fires in chaparral and oak savanna in the southwestern US, as well as pine forest understory in the southeastern US and Sierra Nevada mountains of California. These are likely the most extensive emission factor field measurements for temperate biomass burning to date and the only published emission factors for temperate oak savanna fuels. This study helps close the gap in emissions data available for temperate zone fires relative to tropical biomass burning. We present the first field measurements of the biomass burning emissions of glycolaldehyde, a possible precursor for aqueous phase secondary organic aerosol formation. We also measured the emissions of phenol, another aqueous phase secondary organic aerosol precursor. Our data confirm previous suggestions that urban deposition can impact the NOx emission factors and thus subsequent plume chemistry. For two fires, we measured the emissions in the convective smoke plume from our airborne platform at the same time the unlofted residual smoldering combustion emissions were measured with our ground-based platform after the flame front passed through. The smoke from residual smoldering combustion was characterized by emission factors for hydrocarbon and oxygenated organic species that were up to ten times higher than in the lofted plume, including significant 1,3-butadiene and isoprene concentrations which were not observed in the lofted plume. This should be considered in modeling the air quality impacts of smoke that disperses at ground level, and we show that the normally-ignored unlofted emissions can also significantly impact estimates of total emissions. Preliminary evidence of large emissions of monoterpenes was seen in the residual smoldering spectra, but we have not yet quantified these emissions. These data should lead to an improved capacity to model the impacts of biomass burning in similar

  13. Vehicle and driving characteristics that influence in-cabin particle number concentrations.

    PubMed

    Hudda, Neelakshi; Kostenidou, Evangelia; Sioutas, Constantinos; Delfino, Ralph J; Fruin, Scott A

    2011-10-15

    In-transit microenvironments experience elevated levels of vehicle-related pollutants such as ultrafine particles. However, in-vehicle particle number concentrations are frequently lower than on-road concentrations due to particle losses inside vehicles. Particle concentration reduction occurs due to a complicated interplay between a vehicle's air-exchange rate (AER), which determines particle influx rate, and particle losses due to surfaces and the in-cabin air filter. Accurate determination of inside-to-outside particle concentration ratios is best made under realistic aerodynamic and AER conditions because these ratios and AER are determined by vehicle speed and ventilation preference, in addition to vehicle characteristics such as age. In this study, 6 vehicles were tested at 76 combinations of driving speeds, ventilation conditions (i.e., outside air or recirculation), and fan settings. Under recirculation conditions, particle number attenuation (number reduction for 10-1000 nm particles) averaged 0.83 ± 0.13 and was strongly negatively correlated with increasing AER, which in turn depended on speed and the age of the vehicle. Under outside air conditions, attenuation averaged 0.33 ± 0.10 and primarily decreased at higher fan settings that increased AER. In general, in-cabin particle number reductions did not vary strongly with particle size, and cabin filters exhibited low removal efficiencies. PMID:21928803

  14. Effects of concentrated ambient particles on normal and hypersecretory airways in rats.

    PubMed

    Harkema, Jack R; Keeler, Gerald; Wagner, James; Morishita, Masako; Timm, Edward; Hotchkiss, Jon; Marsik, Frank; Dvonch, Timothy; Kaminski, Norbert; Barr, Edward

    2004-08-01

    in southwestern Detroit during the summer months when particulate air pollution is usually high (July and September 2000). We monitored the outdoor air pollution in this community daily, and exposed normal and compromised rats to concentrated PM2.5 from this local urban atmosphere. Rats in the inhalation studies were exposed for 1 day or for 4 or 5 consecutive days (10 hours/day) to either filtered air (controls) or concentrated ambient particles (CAPs) delivered by a Harvard ambient fine particle concentrator. Rats were killed 24 hours after the end of the exposure. Biochemical, morphometric, and molecular techniques were used to identify airway epithelial and inflammatory responses to CAPs. Lung lobes were also either intratracheally lavaged with saline to determine cellular composition and protein in bronchoalveolar lavage fluid (BALF) or removed for analysis by inductively coupled plasma-mass spectrometry (ICPMS) to detect retention of ambient PM2.5--derived trace elements. The Harvard concentrator effectively concentrated the fine ambient particles from this urban atmosphere (10-30 times) without significantly changing the major physicochemical features of the atmospheric particles. Daily CAPs mass concentrations during the 10-hour exposure period (0800-1800) in July ranged from 16 to 895 microg/m3 and in September ranged from 81 to 755 microg/m3. In general, chemical characteristics of ambient particles were conserved through the concentrator into the exposure chamber. Single or repeated exposures to CAPs did not cause adverse effects in the nasal or pulmonary airways of healthy F344 or BN rats. In addition, CAPs-related toxicity was not observed in F344 rats pretreated with bacterial endotoxin. Variable airway responses to CAPs exposure were observed in BN rats with preexisting allergic airway disease induced by OVA sensitization and challenge. Only OVA-challenged BN rats exposed to CAPs for 5 consecutive days in September 2000 had significant increases in

  15. Analysis of palladium concentrations in airborne particulate matter with reductive co-precipitation, He collision gas, and ID-ICP-Q-MS.

    PubMed

    Alsenz, H; Zereini, F; Wiseman, C L S; Püttmann, W

    2009-11-01

    The concentration of platinum group elements (PGE) in the environment has increased significantly in the last 20 years mainly due to their use as catalysts in automotive catalytic converters. The quantitation of these metals in different environmental compartments is, however, challenging due to their very low concentrations and the presence of interfering matrix constituents when inductively coupled plasma-mass spectrometry (ICP-MS) is used for analysis. Previously, the research focus was on the analysis of platinum (Pt) and rhodium (Rh). However, due to the increasing use of palladium (Pd) in automotive catalytic converters, quantitation of this element in airborne particulate matter (PM) is also needed. Compared to Pt and Rh, measurements of Pd using ICP-MS are plagued by greater molecular interferences arising from elements such as copper (Cu), zinc (Zn) strontium (Sr), yttrium (Y), and zirconium (Zr). The aim of this study was to evaluate the applicability of reductive co-precipitation procedures using both mercury (Hg) and tellurium (Te) for the pre-concentration of Pd from airborne PM. Furthermore, helium (He) was tested as a collision gas for isotope dilution-inductively coupled plasma-quadrupole-mass spectrometry (ID-ICP-Q-MS) to measure Pd in the Hg and Te precipitates. Airborne PM samples (PM10) were collected from Neuglobsow (Brandenburg, north-eastern Germany) and Deuselbach (Rhineland-Palatinate, south-western Germany), considered to represent background levels, and from the city Frankfurt am Main (Hesse, Germany), a high-traffic area. Samples were first digested with aqua regia in a high-pressure asher (HPA) at 320 degrees C and 130 bar prior to the application of reductive co-precipitation procedures. The method was validated with road dust reference material BCR-723 and the CANMET-CCRMP reference material TDB-1 and WPR-1. In airborne PM collected at the background areas Neuglobsow and Deuselbach, Pd was detected with median concentrations values of

  16. Apparatus to collect, classify, concentrate, and characterize gas-borne particles

    DOEpatents

    Rader, Daniel J.; Torczynski, John R.; Wally, Karl; Brockmann, John E.

    2003-12-16

    An aerosol lab-on-a-chip (ALOC) integrates one or more of a variety of particle collection, classification, concentration (enrichment), an characterization processes onto a single substrate or layered stack of such substrates. By mounting a UV laser diode laser light source on the substrate, or substrates tack, so that it is located down-stream of the sample inlet port and at right angle the sample particle stream, the UV light source can illuminate individual particles in the stream to induce a fluorescence response in those particles having a fluorescent signature such as biological particles, some of said particles. An illuminated particle having a fluorescent signal above a threshold signal would trigger a sorter module that would separate that particle from the particle stream.

  17. Variation of particle number concentration and size distributions at the urban environment in Vilnius (Lithuania)

    NASA Astrophysics Data System (ADS)

    Ulevicius, Vidmantas; Byčenkienë, Steigvilë; Plauškaitë, Kristina; Dudoitis, Vadimas

    2013-05-01

    This study presents results of research on urban aerosol particles with a focus on the particle size distribution and the aerosol particle number concentration (PNC). The real time measurements of the aerosol PNC in the size range of 9-840 nm were performed at the urban background site using a Condensed Particle Counter and Scanning Mobility Particle Sizer (SMPS). Strong diurnal patterns in aerosol PNC were evident as a direct effect of three sources of the aerosol particles (nucleation, traffic, and residential heating appliances). The traffic exhaust emissions were a major contributor of the pollution observed at the roadside site that was dominated by the nucleation mode particles, while particles formed due to the residential heating appliances and secondary formation processes contributed to the accumulation mode particles and could impact the variation of PNC and its size distribution during the same day.

  18. Contribution from indoor sources to particle number and mass concentrations in residential houses

    NASA Astrophysics Data System (ADS)

    He, Congrong; Morawska, Lidia; Hitchins, Jane; Gilbert, Dale

    As part of a large study investigating indoor air in residential houses in Brisbane, Australia, the purpose of this work was to quantify emission characteristics of indoor particle sources in 15 houses. Submicrometer particle number and approximation of PM 2.5 concentrations were measured simultaneously for more than 48 h in the kitchen of all the houses by using a condensation particle counter (CPC) and a photometer (DustTrak), respectively. In addition, characterizations of particles resulting from cooking conducted in an identical way in all the houses were measured by using a scanning mobility particle sizer (SMPS), an aerodynamic particle sizer (APS) and a DustTrak. All the events of elevated particle concentrations were linked to indoor activities using house occupants diary entries, and catalogued into 21 different types of indoor activities. This enabled quantification of the effect of indoor sources on indoor particle concentrations as well as quantification of emission rates from the sources. For example, the study found that frying, grilling, stove use, toasting, cooking pizza, cooking, candle vaporizing eucalyptus oil and fan heater use, could elevate the indoor submicrometer particle number concentration levels by more than five times, while PM 2.5 concentrations could be up to 3, 30 and 90 times higher than the background levels during smoking, frying and grilling, respectively.

  19. Influence of compressive strength and applied force in concrete on particles exposure concentrations during cutting processes.

    PubMed

    Soo, Jhy-Charm; Tsai, Perng-Jy; Chen, Ching-Hwa; Chen, Mei-Ru; Hsu, Hsin-I; Wu, Trong-Neng

    2011-08-01

    The objective of this research was to identify the influence of applied force (AF) and the compressive strength (CS) of concrete on particle exposure concentrations during concrete cutting processes. Five cutting conditions were selected with AF varied between 9.8 and 49 N and CS varied between 2500 and 6000 psi. For each selected cutting condition, the measured total dust concentrations (C(tot)) were used to further determine the corresponding three health-related exposure concentrations of the inhalable (C(inh)), thoracic (C(thor)), and respirable fraction (C(res)). Results show that particle size distribution was consistently in a bimodal form under all selected cutting conditions. An increase in CS resulted in an increase in coarse particle generations leading to an increase in the four measured particle exposure levels. An increase in AF resulted in an increase in exposure concentrations with a higher fraction of fine particles (i.e., C(tho) and C(res)) However, for particle exposure concentrations with a higher fraction of coarse particles (i.e., C(tot) and C(inh)), an increase in AF resulted in an initial increase, followed by a decrease in concentration. Finally, the above inferences were further confirmed through the use of fixed-effect models to determine the influence of both CS and AF on the four exposure concentrations. These results provide a reference for industries to initiate appropriate control strategies to reduce the exposure levels encountered by workers. PMID:21621248

  20. [Comparing Cell Toxicity of Schizosaccharomyces pombe Exposure to Airborne PM2.5 from Beijing and Inert Particle SiO2].

    PubMed

    Liu, Meng-jiao; Huang, Yi; Wen, Hang; Qiu, Guo-yu

    2015-11-01

    To figure out the main factor of PM2.5 toxicity to cell, this study compared the cell toxicity of Schizosaccharomyces pombe (S. pombe), a model organism, exposed to inert ultrafine SiO2 particles, a model particle, and airborne PM2.5 collected from campus of Peking University Beijing China. Using ultraviolet spectrophotometry to measure cell proliferation ratio, and environmental scanning microscope to observe the particle adhesion on the cell surface, and detecting cellular ROS generation with DHE fluorescent dye chromogenic method, and using single cell gel electrophoresis to test cell DNA damage, the experiment results indicated that the ultrafine SiO2 particles (< 60 nm) could inhibit the cell proliferation of S. pombe, mainly through adsorbing onto the cell surface to change the permeability of the cell wall; but it could not induce cells to generate ROS to cause the oxidative damage. PM2.5, the average particle size of which was larger than that of SiO2 particles, could cause oxidative damages to cells mainly by inducing cells to generate ROS, and damage DNA simultaneously. It might illustrate that there was no direct relationship between the toxicity of PM2.5 and its physical properties such as the particle size. PMID:26910977

  1. Potential airborne release from soil-working operations in a contaminated area

    SciTech Connect

    Sutter, S.L.

    1980-08-01

    Experiments were performed to provide an indication of how much material could be made airborne during soil-working operations in a contaminated area. Approximately 50 kg of contaminated soil were collected, dried, and mixed, and particle size distribution and /sup 137/Cs content were characterized. In four experiments performed in a 2 ft x 2 ft wind tunnel at the Radioactive Aerosol Release Test Facility, soil was pumped into an airstream moving at 3.2, 10.4, 15.2, and 20 mph. These experiments were designed to maximize airborne releases by fluidizing the soil as it was pumped into the wind tunnel. Thus the airborne releases should represent upper limit values for soil-working operations. Airborne concentration and particle size samples were collected and all of the material deposited downstream was collected to calculate a mass balance. The fraction airborne was calculated using these measurements.

  2. A single-particle characterization of a mobile Versatile Aerosol Concentration Enrichment System for exposure studies

    PubMed Central

    Freney, Evelyn J; Heal, Mathew R; Donovan, Robert J; Mills, Nicholas L; Donaldson, Kenneth; Newby, David E; Fokkens, Paul HB; Cassee, Flemming R

    2006-01-01

    Background An Aerosol Time-of-Flight Mass Spectrometer (ATOFMS) was used to investigate the size and chemical composition of fine concentrated ambient particles (CAPs) in the size range 0.2–2.6 μm produced by a Versatile Aerosol Concentration Enrichment System (VACES) contained within the Mobile Ambient Particle Concentrator Exposure Laboratory (MAPCEL). The data were collected during a study of human exposure to CAPs, in Edinburgh (UK), in February-March 2004. The air flow prior to, and post, concentration in the VACES was sampled in turn into the ATOFMS, which provides simultaneous size and positive and negative mass spectral data on individual fine particles. Results The particle size distribution was unaltered by the concentrator over the size range 0.2–2.6 μm, with an average enrichment factor during this study of ~5 (after dilution of the final air stream). The mass spectra from single particles were objectively grouped into 20 clusters using the multivariate K-means algorithm and then further grouped manually, according to similarity in composition and time sequence, into 8 main clusters. The particle ensemble was dominated by pure and reacted sea salt and other coarse inorganic dusts (as a consequence of the prevailing maritime-source climatology during the study), with relatively minor contributions from carbonaceous and secondary material. Very minor variations in particle composition were noted pre- and post-particle concentration, but overall there was no evidence of any significant change in particle composition. Conclusion These results confirm, via single particle analysis, the preservation of the size distribution and chemical composition of fine ambient PM in the size range 0.2–2.6 μm after passage through the VACES concentration instrumentation. PMID:16723024

  3. Characterisation of particle emissions from the driving car fleet and the contribution to ambient and indoor particle concentrations

    NASA Astrophysics Data System (ADS)

    Palmgren, Finn; Wåhlin, Peter; Kildesø, Jan; Afshari, Alireza; Fogh, Christian L.

    The population is mainly exposed to high air pollution concentrations in the urban environment, where motor vehicle emissions constitute the main source of fine and ultrafine particles. These particles can penetrate deep into the respiratory system, and studies indicate that the smaller the particle, the larger the health impacts. The chemical composition, surface reactivity and physical properties are also important. However, the knowledge about chemical and physical properties of particles and the temporal and spatial variability of the smallest particles is still very limited. The present study summarises the first results of a larger project with the aims to improve the knowledge. The concentration and the emissions of ultrafine particles from petrol and diesel vehicles, respectively, have been quantified using Scanning Mobility Particle Sizer of ultrafine particles in the size range 6-700 nm and routine monitoring data from urban streets and urban background in Denmark. The quantification was carried out using receptor modelling. The number size distributions of petrol and diesel emissions showed a maximum at 20-30 nm and non-traffic at ≈100 nm. The contribution of ultrafine particles from diesel vehicles is dominating in streets. The same technique has been applied on PM 10, and ≈50% contribution from non-traffic. The technique has also been introduced in relation to elemental and organic carbon, and the first data showed strong correlation between traffic pollution and elemental carbon. The outdoor air quality has a significant effect on indoor pollution levels, and we spend most of the time indoors. Knowledge about the influence of ambient air pollution on the concentrations in the indoor environment is therefore crucial for assessment of human health effects of traffic pollution. The results of our studies will be included in air quality models for calculation of human exposure. Preliminary results from our first campaign showed, that the deposition

  4. Particle number concentration, size distribution and chemical composition during haze and photochemical smog episodes in Shanghai.

    PubMed

    Wang, Xuemei; Chen, Jianmin; Cheng, Tiantao; Zhang, Renyi; Wang, Xinming

    2014-09-01

    The aerosol number concentration and size distribution as well as size-resolved particle chemical composition were measured during haze and photochemical smog episodes in Shanghai in 2009. The number of haze days accounted for 43%, of which 30% was severe (visibility<2km) and moderate (2km≤visibility<3km) haze, mainly distributed in winter and spring. The mean particle number concentration was about 17,000/cm(3) in haze, more than 2 times that in clean days. The greatest increase of particle number concentration was in 0.5-1μm and 1-10μm size fractions during haze events, about 17.78 times and 8.78 times those of clean days. The largest increase of particle number concentration was within 50-100nm and 100-200nm fractions during photochemical smog episodes, about 5.89 times and 4.29 times those of clean days. The particle volume concentration and surface concentration in haze, photochemical smog and clean days were 102, 49, 15μm(3)/cm(3) and 949, 649, 206μm(2)/cm(3), respectively. As haze events got more severe, the number concentration of particles smaller than 50nm decreased, but the particles of 50-200nm and 0.5-1μm increased. The diurnal variation of particle number concentration showed a bimodal pattern in haze days. All soluble ions were increased during haze events, of which NH4(+), SO4(2-) and NO3(-) increased greatly, followed by Na(+), K(+), Ca(2+) and Cl(-). These ions were very different in size-resolved particles during haze and photochemical smog episodes. PMID:25193840

  5. Characterization of Size-Fractionated Airborne Particles Inside an Electronic Waste Recycling Facility and Acute Toxicity Testing in Mice.

    PubMed

    Kim, Yong Ho; Wyrzykowska-Ceradini, Barbara; Touati, Abderrahmane; Krantz, Q Todd; Dye, Janice A; Linak, William P; Gullett, Brian; Gilmour, M Ian

    2015-10-01

    Disposal of electronic waste (e-waste) in landfills, incinerators, or at rudimentary recycling sites can lead to the release of toxic chemicals into the environment and increased health risks. Developing e-waste recycling technologies at commercial facilities can reduce the release of toxic chemicals and efficiently recover valuable materials. While these e-waste operations represent a vast improvement over previous approaches, little is known about environmental releases, workplace exposures, and potential health impacts. In this study, airborne particulate matter (PM) was measured at various locations within a modern U.S.-based e-waste recycling facility that utilized mechanical processing. In addition, composite size fractionated PM (coarse, fine and ultrafine) samples were collected, extracted, chemically analyzed, and given by oropharyngeal aspiration to mice or cultured with lung slices for lung toxicity tests. Indoor total PM concentrations measured during the study ranged from 220 to 1200 μg/m(3). In general, the coarse PM (2.5-10 μm) was 3-4 times more abundant than fine/ultrafine PM (<2.5 μm). The coarse PM contained higher levels of Ni, Pb, and Zn (up to 6.8 times) compared to the fine (0.1-2.5 μm) and ultrafine (<0.1 μm) PM. Compared to coarse PM measurements from a regional near-roadway study, Pb and Ni were enriched 170 and 20 times, respectively, in the indoor PM, with other significant enrichments (>10 times) observed for Zn and Sb, modest enrichments (>5 times) for Cu and Sr, and minor enrichments (>2 times) for Cr, Cd, Mn, Ca, Fe, and Ba. Negligible enrichment (<2 times) or depletion (<1 time) were observed for Al, Mg, Ti, Si, and V. The coarse PM fraction elicited significant pro-inflammatory responses in the mouse lung at 24 h postexposure compared to the fine and ultrafine PM, and similar toxicity outcomes were observed in the lung slice model. We conclude that exposure to coarse PM from the facility caused substantial inflammation in the

  6. Development of a new methodology for the retrieval of in-situ stratospheric trace gases concentration from airborne limb-absorption measurements

    NASA Astrophysics Data System (ADS)

    Petritoli, Andrea; Giovanelli, Giorgio; Ravegnani, Fabrizio; Bortoli, Daniele; Kostadinov, Ivan K.; Castelli, Elisa; Bonafe, U.; Oulanovsky, A.; Yushkov, Vladimir

    2002-01-01

    The UV-Vis DOAS spectrometer GASCOD/A4p (Gas Analyzer Spectrometer Correlating Optical Differences, Airborne version) was installed on board the stratospheric Geophysica aircraft during the APE-THESEO and APE-GAIA campaign in February-March and September-October 1999 respectively. The instrument is provided by five input windows, three of which measure scattered solar radiation from the zenith and from two horizontal windows, 90 degree(s) away from the zenith to perform limb-absorption measurements. Spectra from 290 to 700 nm were processed through DOAS technique to obtain trace gases column amounts. Data from horizontal windows, which are performed for the first time from an airborne spectrometer, are used to retrieve an average concentration of the gases along a characteristic length of the line of sight. An atmospheric Air Mass Factor model (AMEFCO) is used to calculate the probability density function and the characteristic length used to reduce the slant column amounts to in-situ concentration values. The validation of the method is performed through a comparison of the values obtained, with a in-situ chemiluminescent ozone analyzer (FOZAN) which performed synchronous measurements on board Geophysica aircraft. Data from the APE-GAIA campaign was presented and discussed.

  7. Hydrogen Reduction Kinetics of Magnetite Concentrate Particles Relevant to a Novel Flash Ironmaking Process

    NASA Astrophysics Data System (ADS)

    Wang, Haitao; Sohn, H. Y.

    2013-02-01

    A novel ironmaking technology is under development at the University of Utah. The purpose of this research was to determine comprehensive kinetics of the flash reduction reaction of magnetite concentrate particles by hydrogen. Experiments were carried out in the temperature range of 1423 K to 1673 K (1150 °C to 1400 °C) with the other experimental variables being hydrogen partial pressure and particle size. The nucleation and growth kinetics expression was found to describe the reduction rate of fine concentrate particles and the reduction kinetics had a 1/2-order dependence on hydrogen partial pressure and an activation energy of 463 kJ/mol. Unexpectedly, large concentrate particles reacted faster at 1423 K and 1473 K (1150 °C and 1200 °C), but the effect of particle size was negligible when the reduction temperature was above 1573 K (1300 °C). A complete reaction rate expression incorporating all these factors was formulated.

  8. On-Road measurement of particulate matter emissions from vehicles: particle concentration, size distribution and morphology

    NASA Astrophysics Data System (ADS)

    Salvadori, N.; China, S.; Cook, J.; Kuhns, H. D.; Moosmuller, H.; Mazzoleni, C.

    2010-12-01

    During summer 2010, we conducted a field experiment in Southern Michigan to measure on-road vehicle emissions. During the campaign, particulate matter (PM) concentrations were monitored with a Light Detection and Ranging (Lidar) and transmissometer system. The Lidar and transmissometer system measures PM mass concentration of vehicle exhaust using backscatter and extinction of an ultraviolet laser beam directed across the road. Collocated with the Lidar system we deployed an extractive system inclusive of a LiCor 840 to monitor CO2 concentrations, a laser aerosol spectrometer to measure particle size distributions for PM with diameter larger than 0.1 µm, and a portable condensation particle counter to estimate the total particle number concentration for particles with diameters between~30nm and 1 µm. In addition, road-side vehicle exhaust particles were collected on nuclepore filters for scanning electron microscopy analysis during selected periods of time. In this study we analyze fuel-based mass and number PM emission factors from passing vehicles. The emission factors are estimated normalizing the PM data by the CO2 concentration. The morphology of the particulates is also investigated with electron microscopy analysis. Type of vehicles and traffic counts were recorded by one of the researchers during the sampling period to evaluate the influence on particle morphology due to traffic volume and fuel type. Image processing and fractal geometry are used to estimate various morphological parameters and fractal dimension. Diurnal variation of particle morphology descriptors and fractal dimension of soot particles are investigated and compared with CO2 emissions, particle size distribution and particle number concentration for selected subsets of the data. Variations of PM emission factors and PM morphology are also investigated for different traffic conditions and days of the week. The analysis of the PM data is of particular importance in monitoring vehicle

  9. Shear-induced particle diffusion and its effects on the flow of concentrated suspensions

    SciTech Connect

    Acrivos, A.

    1996-12-31

    The mechanism underlying shear-induced particle diffusion in concentrated suspensions is clarified. Examples are then presented where this diffusion process plays a crucial role in determining the manner by which such suspensions flow under laminar conditions.

  10. Modeling particle number concentrations along Interstate 10 in El Paso, Texas

    PubMed Central

    Olvera, Hector A.; Jimenez, Omar; Provencio-Vasquez, Elias

    2014-01-01

    Annual average daily particle number concentrations around a highway were estimated with an atmospheric dispersion model and a land use regression model. The dispersion model was used to estimate particle concentrations along Interstate 10 at 98 locations within El Paso, Texas. This model employed annual averaged wind speed and annual average daily traffic counts as inputs. A land use regression model with vehicle kilometers traveled as the predictor variable was used to estimate local background concentrations away from the highway to adjust the near-highway concentration estimates. Estimated particle number concentrations ranged between 9.8 × 103 particles/cc and 1.3 × 105 particles/cc, and averaged 2.5 × 104 particles/cc (SE 421.0). Estimates were compared against values measured at seven sites located along I10 throughout the region. The average fractional error was 6% and ranged between -1% and -13% across sites. The largest bias of -13% was observed at a semi-rural site where traffic was lowest. The average bias amongst urban sites was 5%. The accuracy of the estimates depended primarily on the emission factor and the adjustment to local background conditions. An emission factor of 1.63 × 1014 particles/veh-km was based on a value proposed in the literature and adjusted with local measurements. The integration of the two modeling techniques ensured that the particle number concentrations estimates captured the impact of traffic along both the highway and arterial roadways. The performance and economical aspects of the two modeling techniques used in this study shows that producing particle concentration surfaces along major roadways would be feasible in urban regions where traffic and meteorological data are readily available. PMID:25313294

  11. Modeling particle number concentrations along Interstate 10 in El Paso, Texas.

    PubMed

    Olvera, Hector A; Jimenez, Omar; Provencio-Vasquez, Elias

    2014-12-01

    Annual average daily particle number concentrations around a highway were estimated with an atmospheric dispersion model and a land use regression model. The dispersion model was used to estimate particle concentrations along Interstate 10 at 98 locations within El Paso, Texas. This model employed annual averaged wind speed and annual average daily traffic counts as inputs. A land use regression model with vehicle kilometers traveled as the predictor variable was used to estimate local background concentrations away from the highway to adjust the near-highway concentration estimates. Estimated particle number concentrations ranged between 9.8 × 10(3) particles/cc and 1.3 × 10(5) particles/cc, and averaged 2.5 × 10(4) particles/cc (SE 421.0). Estimates were compared against values measured at seven sites located along I10 throughout the region. The average fractional error was 6% and ranged between -1% and -13% across sites. The largest bias of -13% was observed at a semi-rural site where traffic was lowest. The average bias amongst urban sites was 5%. The accuracy of the estimates depended primarily on the emission factor and the adjustment to local background conditions. An emission factor of 1.63 × 10(14) particles/veh-km was based on a value proposed in the literature and adjusted with local measurements. The integration of the two modeling techniques ensured that the particle number concentrations estimates captured the impact of traffic along both the highway and arterial roadways. The performance and economical aspects of the two modeling techniques used in this study shows that producing particle concentration surfaces along major roadways would be feasible in urban regions where traffic and meteorological data are readily available. PMID:25313294

  12. Modeling particle number concentrations along Interstate 10 in El Paso, Texas

    NASA Astrophysics Data System (ADS)

    Olvera, Hector A.; Jimenez, Omar; Provencio-Vasquez, Elias

    2014-12-01

    Annual average daily particle number concentrations around a highway were estimated with an atmospheric dispersion model and a land use regression model. The dispersion model was used to estimate particle concentrations along Interstate 10 at 98 locations within El Paso, Texas. This model employed annual averaged wind speed and annual average daily traffic counts as inputs. A land use regression model with vehicle kilometers traveled as the predictor variable was used to estimate local background concentrations away from the highway to adjust the near-highway concentration estimates. Estimated particle number concentrations ranged between 9.8 × 103 particles/cc and 1.3 × 105 particles/cc, and averaged 2.5 × 104 particles/cc (SE 421.0). Estimates were compared against values measured at seven sites located along I10 throughout the region. The average fractional error was 6% and ranged between -1% and -13% across sites. The largest bias of -13% was observed at a semi-rural site where traffic was lowest. The average bias amongst urban sites was 5%. The accuracy of the estimates depended primarily on the emission factor and the adjustment to local background conditions. An emission factor of 1.63 × 1014 particles/veh-km was based on a value proposed in the literature and adjusted with local measurements. The integration of the two modeling techniques ensured that the particle number concentrations estimates captured the impact of traffic along both the highway and arterial roadways. The performance and economical aspects of the two modeling techniques used in this study shows that producing particle concentration surfaces along major roadways would be feasible in urban regions where traffic and meteorological data are readily available.

  13. POTENTIAL CONTRIBUTION OF SULFATE PRODUCTION IN CUMULUS CLOUD DROPLETS TO GROUND LEVEL PARTICLE SULFUR CONCENTRATIONS

    EPA Science Inventory

    Relationships have been examined between the presence or absence of cumulus clouds and 3rd quarter fine particle sulfur concentrations in St. Louis. An association between the presence of cumulus clouds with SO2 conversions in droplets and incrementally higher fine particle sulfu...

  14. Organic compounds present in airborne particles stimulate superoxide production and DNA fragmentation: role of NOX and xanthine oxidase in animal tissues.

    PubMed

    Busso, Iván Tavera; Silva, Guillermo Benjamín; Carreras, Hebe Alejandra

    2016-08-01

    Suspended particulate matter trigger the production of reactive oxygen species. However, most of the studies dealing with oxidative damage of airborne particles focus on the effects of individual compounds and not real mixtures. In order to study the enzymatic superoxide production resulting from the exposition to a complex mixture, we derived organic extracts from airborne particles collected daily in an urban area and exposed kidney, liver, and heart mammal tissues. After that, we measured DNA damage employing the comet assay. We observed that in every tissue, NADPH oxidase and xanthine oxidase were involved in O2 (-) production when they were exposed to the organic extracts, as the lucigenin's chemiluminescence decays when enzymes were inhibited. The same trend was observed with the percentage of cells with comets, since DNA damage was higher when they were exposed to same experimental conditions. Our data allow us to hypothesize that these enzymes play an important role in the oxidative stress produced by PAHs and that there is a mechanism involving them in the O2 (-)generation. PMID:27180836

  15. Emission of submicron aerosol particles in cement kilns: Total concentration and size distribution.

    PubMed

    Rotatori, Mauro; Mosca, Silvia; Guerriero, Ettore; Febo, Antonio; Giusto, Marco; Montagnoli, Mauro; Bianchini, Massimo; Ferrero, Renato

    2015-01-01

    Cement plants are responsible for particle and gaseous emissions into the atmosphere. With respect to particle emission, the greater part of is in the range from 0.05 to 5.0 µm in diameter. In the last years attention was paid to submicron particles, but there is a lack of available data on the emission from stationary sources. In this paper, concentration and size distribution of particles emitted from four cement kilns, in relationship to operational conditions (especially the use of alternative fuel to coal) of the clinker process are reported. Experimental campaigns were carried out by measuring particles concentration and size distribution at the stack of four cement plants through condensation particle counter (CPC) and scanning mobility particle sizer spectrometer (SMPS). Average total particle number concentrations were between 2000 and 4000 particles/cm³, about 8-10 times lower that those found in the corresponding surrounding areas. As for size distribution, for all the investigated plants it is stable with a unimodal distribution (120-150 nm), independent from the fuel used. PMID:25946956

  16. Determination of heavy metals concentrations in airborne particulates matter (APM) from Manjung district, Perak using energy dispersive X-ray fluorescence (EDXRF) spectrometer

    NASA Astrophysics Data System (ADS)

    Arshad, Nursyairah; Hamzah, Zaini; Wood, Ab. Khalik; Saat, Ahmad; Alias, Masitah

    2015-04-01

    Airborne particulates trace metals are considered as public health concern as it can enter human lungs through respiratory system. Generally, any substance that has been introduced to the atmosphere that can cause severe effects to living things and the environment is considered air pollution. Manjung, Perak is one of the development districts that is active with industrial activities. There are many industrial activities surrounding Manjung District area such as coal fired power plant, quarries and iron smelting which may contribute to the air pollution into the environment. This study was done to measure the concentrations of Hg, U, Th, K, Cu, Fe, Cr, Zn, As, Se, Pb and Cd in the Airborne Particulate Matter (APM) collected at nine locations in Manjung District area within 15 km radius towards three directions (North, North-East and South-East) in 5 km intervals. The samples were collected using mini volume air sampler with cellulose filter through total suspended particulate (TSP). The sampler was set up for eight hours with the flow rate of 5 L/min. The filter was weighed before and after sample collection using microbalance, to get the amount of APM and kept in desiccator before analyzing. The measurement was done using calibrated Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer. The air particulate concentrations were found below the Malaysia Air Quality Guidelines for TSP (260 µg/m3). All of the metals concentrations were also lower than the guidelines set by World Health Organization (WHO), Ontario Ministry of the Environment and Argonne National Laboratory, USA NCRP (1975). From the concentrations, the enrichment factor were calculated.

  17. Influence of dust-particle concentration on gas-discharge plasma

    SciTech Connect

    Sukhinin, G. I.; Fedoseev, A. V.

    2010-01-15

    A self-consistent kinetic model of a low-pressure dc glow discharge with dust particles based on Boltzmann equation for the electron energy distribution function is presented. The ions and electrons production in ionizing processes as well as their recombination on the dust-particle surface and on the discharge tube wall were taken into account. The influence of dust-particle concentration N{sub d} on gas discharge and dust particles parameters was investigated. It is shown that the increase of N{sub d} leads to the increase of an averaged electric field and ion density, and to the decrease of a dust-particle charge and electron density in the dusty cloud. The results were obtained in a wide region of different discharge and dusty plasma parameters: dust particles density 10{sup 2}-10{sup 8} cm{sup -3}, discharge current density 10{sup -1}-10{sup 1} mA/cm{sup 2}, and dust particles radius 1, 2, and 5 mum. The scaling laws for dust-particle surface potential and electric filed dependencies on dust-particle density, particle radius and discharge currents were revealed. It is shown that the absorption of electrons and ions on the dust particles surface does not lead to the electron energy distribution function depletion due to a self-consistent adjustment of dust particles and discharge parameters.

  18. Effects of concentrated ambient particles on heart rate and blood pressure in pulmonary hypertensive rats.

    PubMed Central

    Cheng, Tsun-Jen; Hwang, Jing-Shiang; Wang, Peng-Yau; Tsai, Chia-Fang; Chen, Chun-Yen; Lin, Sheng-Hsiang; Chan, Chang-Chuan

    2003-01-01

    Epidemiologic studies have shown that increased concentrations of ambient particles are associated with cardiovascular morbidity and mortality. However, the exact mechanisms remain unclear. Recent studies have revealed that particulate air pollution exposure is associated with indicators of autonomic function including heart rate, blood pressure, and heart rate variability. However, this association has not been clearly demonstrated in animal studies. To overcome the problems of wide variations in diseased animals and circadian cycles, we adopted a novel approach using a mixed-effects model to investigate whether ambient particle exposure was associated with changes in heart rate and blood pressure in pulmonary hypertensive rats. Male Sprague-Dawley rats were implanted with radiotelemetry devices and exposed to concentrated ambient particles generated by an air particle concentrator. The rats were held in nose-only exposure chambers for 6 hr per day for 3 consecutive days and then rested for 4 days in each week during the experimental period of 5 weeks. These animals were exposed to concentrated particles during weeks 2, 3, and 4 and exposed to filtered air during weeks 1 and 5. The particle concentrations for tested animals ranged between 108 and 338 micro g/m(3). Statistical analysis using mixed-effects models revealed that entry and exit of exposure chamber and particle exposure were associated with changes in heart rate and mean blood pressure. Immediately after particle exposure, the hourly averaged heart rate decreased and reached the lowest at the first and second hour of exposure for a decrease of 14.9 (p < 0.01) and 11.7 (p = 0.01) beats per minute, respectively. The hourly mean blood pressure also decreased after the particle exposure, with a maximal decrease of 3.3 (p < 0.01) and 4.1 (p < 0.01) mm Hg at the first and second hour of exposure. Our results indicate that ambient particles might influence blood pressure and heart rate. PMID:12573896

  19. Mapping methane concentrations from a controlled release experiment using the next generation Airborne Visible/Infrared Imaging Spectrometer (AVIRISng)

    NASA Astrophysics Data System (ADS)

    Thorpe, A. K.; Frankenberg, C.; Roberts, D. A.; Aubrey, A. D.; Green, R. O.; Hulley, G. C.; Hook, S. J.

    2014-12-01

    Airborne imaging spectrometers like the next generation Airborne Visible/Infrared Imaging Spectrometer (AVIRISng) are well suited for monitoring local methane sources by covering large regions with the high spatial resolution necessary to resolve emissions. As part of a field campaign with controlled methane releases at the Rocky Mountain Oilfield Testing Center (RMOTC), a number of methane plumes were clearly visible at multiple flux rates and flight altitudes. Images of plumes appeared consistent with wind directions measured at ground stations and were present for fluxes as low as 14.2 cubic meters of methane per hour, equivalent to 0.09 kt/year. Direct comparison of results from AVIRISng and plume dispersion models is ongoing and will be used to assess the potential of constraining emission fluxes using AVIRISng. Methane plumes observed at RMOTC with the Hyperspectral Thermal Emission Spectrometer (HyTES) will also be presented. This controlled release experiment was used to determine the methane sensitivity of AVIRISng and inform sensor design for future imaging spectrometers that could constrain natural and anthropogenic methane emissions on local and regional scales. Imaging spectrometers permit direct attribution of emissions to individual point sources which is particularly useful given the large uncertainties associated with anthropogenic emissions, including industrial point source emissions and fugitive methane from the oil and gas industry. Figure caption: a. AVIRISng true color image indicating tube trailer (TT), meteorological tower (MT), and release point (RP). b. Prominent methane plume and measured enhancements for 70.8 cubic meters per hour methane flux is consistent with wind speed and direction (see arrow) measured by meteorological tower. A linear transect is shown in red and corresponds to enhancements shown in c. d. True color image showing release point (RP). e. Smaller methane plume for 14.2 cubic meters per hour flux. f. Methane

  20. The Effect of Particle Concentration on the Heating Rate of Ferrofluids for Magnetic Hyperthermia

    NASA Astrophysics Data System (ADS)

    Malaescu, I.; Marin, C. N.; Bunoiu, M.; Fannin, P. C.; Stefu, N.; Iordaconiu, L.

    2015-12-01

    The complex magnetic susceptibility χ(f) = χ'(f) - i χ″(f), of a ferrofluid sample with magnetite particles dispersed in kerosene and stabilized with oleic acid, over the range 0.1 GHz to 6 GHz, was determined. The initial sample has been successively diluted with kerosene (with a dilution rate of 2/3), thus obtaining further three samples. Using the complex magnetic susceptibility measurements of each sample, the frequency field and particle concentration dependencies of the heating rate of the ferrofluid samples, were analyzed. The results show the possibility of using the heating rate of ferrofluid samples with different particle concentrations, in hyperthermia applications.

  1. Wood dust particle and mass concentrations and filtration efficiency in sanding of wood materials.

    PubMed

    Welling, Irma; Lehtimäki, Matti; Rautio, Sari; Lähde, Tero; Enbom, Seppo; Hynynen, Pasi; Hämeri, Kaarle

    2009-02-01

    The importance of fine particles has become apparent as the knowledge of their effects on health has increased. Fine particle concentrations have been published for outside air, plasma arc cutting, welding, and grinding, but little data exists for the woodworking industry. Sanding was evaluated as the producer of the woodworking industry's finest particles, and was selected as the target study. The number of dust particles in different particle size classes and the mass concentrations were measured in the following environments: workplace air during sanding in plywood production and in the inlet and return air; in the dust emission chamber; and in filter testing. The numbers of fine particles were low, less than 10(4) particles/cm(3) (10(7) particles/L). They were much lower than typical number concentrations near 10(6) particles/cm(3) measured in plasma arc cutting, grinding, and welding. Ultrafine particles in the size class less than 100 nm were found during sanding of MDF (medium density fiberboard) sheets. When the cleaned air is returned to the working areas, the dust content in extraction systems must be monitored continuously. One way to monitor the dust content in the return air is to use an after-filter and measure pressure drop across the filter to indicate leaks in the air-cleaning system. The best after-filtration materials provided a clear increase in pressure drop across the filter in the loading of the filter. The best after-filtration materials proved to be quite effective also for fine particles. The best mass removal efficiencies for fine particles around 0.3 mum were over 80% for some filter materials loaded with sanding wood dust. PMID:19065389

  2. Exposure to particle number, surface area and PM concentrations in pizzerias

    NASA Astrophysics Data System (ADS)

    Buonanno, G.; Morawska, L.; Stabile, L.; Viola, A.

    2010-10-01

    The aim of this work was to quantify exposure to particles emitted by wood-fired ovens in pizzerias. Overall, 15 microenvironments were chosen and analyzed in a 14-month experimental campaign. Particle number concentration and distribution were measured simultaneously using a Condensation Particle Counter (CPC), a Scanning Mobility Particle Sizer (SMPS), an Aerodynamic Particle Sizer (APS). The surface area and mass distributions and concentrations, as well as the estimation of lung deposition surface area and PM 1 were evaluated using the SMPS-APS system with dosimetric models, by taking into account the presence of aggregates on the basis of the Idealized Aggregate (IA) theory. The fraction of inhaled particles deposited in the respiratory system and different fractions of particulate matter were also measured by means of a Nanoparticle Surface Area Monitor (NSAM) and a photometer (DustTrak DRX), respectively. In this way, supplementary data were obtained during the monitoring of trends inside the pizzerias. We found that surface area and PM 1 particle concentrations in pizzerias can be very high, especially when compared to other critical microenvironments, such as the transport hubs. During pizza cooking under normal ventilation conditions, concentrations were found up to 74, 70 and 23 times higher than background levels for number, surface area and PM 1, respectively. A key parameter is the oven shape factor, defined as the ratio between the size of the face opening in respect to the diameter of the semicircular oven door, and particular attention must also be paid to hood efficiency.

  3. Airborne concentrations, skin contamination, and urinary metabolite excretion of polycyclic aromatic hydrocarbons among paving workers exposed to coal tar derived road tars

    SciTech Connect

    Jongeneelen, F.J.; Scheepers, P.T.; Groenendijk, A.; Van Aerts, L.A.; Anzion, R.B.; Bos, R.P.; Veenstra, S.J.

    1988-12-01

    The exposure of surface dressing workers to polycyclic aromatic hydrocarbons (PAH) was studied. Four different paving sites, at which coal tar-containing binders were applied, were selected as work sites with high exposure levels of PAH. Breathing zone airborne particulates, contamination of the skin with PAH, and 1-hydroxypyrene in urine of the workers involved in chip sealing were determined. Substantial concentrations of cyclohexane-soluble airborne particulate matter were found (GM = 0.2 mg/m3, n = 28). Skin contamination was determined using two different methods: with exposure pads and by hand washing. Pads were mounted on several parts of the body: wrist, elbow, neck, shoulder, and ankle. The pads located on the wrist appeared to be the most contaminated (pyrene: GM = 22 ng/1.77 cm2, n = 40). The end-of-shift hand washing showed that the hands of the workers were contaminated with PAH (pyrene: GM = 70 micrograms, n = 35). Preshift hand washing showed far lower, but detectable, quantities of PAH on workers' hands (pyrene: GM = 5 micrograms, n = 35). Enhanced levels of urinary 1-hydroxypyrene among the workers were found. The highest levels were found in the end-of-shift urine samples. Correlations between the pyrene exposure variables were studied. Significant positive correlations were found between pyrene on the wrist pad versus end-of-shift urinary 1-hydroxypyrene; between pyrene on the hands versus end-of-shift urinary 1-hydroxypyrene; and between the two different skin contamination variables.

  4. Transport and Retention of Engineered Nanoporous Particles in Porous Media: Effects of Concentration and Flow Dynamics

    SciTech Connect

    Shang, Jianying; Liu, Chongxuan; Wang, Zheming

    2013-01-20

    Engineered nanoporous particles are an important class of nano-structured materials that can be functionalized in their internal surfaces for various applications including groundwater contaminant sequestration. This paper reported a study of transport and retention of engineered nanoporous silicate particles (ENSPs) that are designed for treatment and remediation of contaminants such as uranium in groundwater and sediments. The transport and retention of ENSPs were investigated under variable particle concentrations and dynamic flow conditions in a synthetic groundwater that mimics field groundwater chemical composition. The dynamic flow condition was achieved using a flow-interruption (stop-flow) approach with variable stop-flow durations to explore particle retention and release kinetics. The results showed that the ENSPs transport was strongly affected by the particle concentrations and dynamic flow conditions. A lower injected ENSPs concentration and longer stop-flow duration led to a more particle retention. The experimental data were used to evaluate the applicability of various kinetic models that were developed for colloidal particle retention and release in describing ENSPs transport. Model fits suggested that the transport and retention of ENSPs were subjected to a complex coupling of reversible attachment/detachment and straining/liberation processes. Both experimental and modeling results indicated that dynamic groundwater flow condition is an important parameter to be considered in exploring and modeling engineered particle transport in subsurface porous media.

  5. A method for computing the damage level due to the exposure to an airborne chemical with a time-varying concentration.

    PubMed

    Acquesta, Alejandro D; Sánchez, Erica Yanina; Porta, Andres; Jacovkis, Pablo M

    2011-09-01

    The calculation of damage level due to the exposure to a toxic cloud is usually not included in most popular software, or it is included using techniques that do not take into account the variation in concentration over a period of time. In this work, a method is introduced for calculating the temporal evolution of the potential damage level and to obtain a more precise and descriptive estimation of this level. The proposed goal is: to estimate the maximum and minimum damage level experienced by a population due to the exposure to an airborne chemical with a time-varying concentration; to be able to assess the damage level experienced in a progressive way, as the exposure to the airborne chemical occurs. The method relies on transformations of time-concentration pairs on a continuum of damage level curves based on the available guideline levels, obtaining maximum and minimum approximations of the expected damage level for any exposure duration. Consequently, applying this method to transport model output data and demographic information, damage evolution in relation to time and space can be predicted, as well as its effect on the local population, which enables the determination of threat zones. The comparison between the proposed method and the current (Spanish and ALOHA) ones showed that the former can offer a more precise estimation and a more descriptive approach of the potential damage level. This method can be used by atmospheric dispersion models to compute damage level and graphically display the regions exposed to each guideline level on area maps. PMID:21395635

  6. Emission of airborne fibers from mechanically impacted asbestos-cement sheets and concentration of fibrous aerosol in the home environment in Upper Silesia, Poland.

    PubMed

    Pastuszka, Jozef S

    2009-03-15

    The emission rate ((S)) of fibers released from asbestos-cement plates due to mechanical impact was determined experimentally. The emission rate has been defined as a number of fibers (F) emitted from a unit area (m(2)) due to the unit impact energy (J). For fiber longer than 5 microm the obtained surface emission factor for asbestos-cement slabs slightly increased with deteriorating surface, changing from 2.7 x 10(3) F/(m(2)J) for samples with a very good surface to 6.9 x 10(3) F/(m(2)J) for the sample with worn surface (in the SI system the emission rate unit should be (m(-2)J(-1))). The emission rate for short fibers (L < or = 5 microm) was little higher compared with emission of long fibers for all studied asbestos materials. The averaged emission rate for all studied samples was about 5000 and 6000 of long and short fibers, respectively, emitted per square meter (because of the impact energy equal to 1J). The dominating population of emitted fibers ranged from 2 to around 8 microm in length. The second part of this work constitutes the report on the concentration of airborne respirable fibers, and their length distribution in two different groups of homes in Upper Silesia, Poland. Mean concentration level of the respirable fibers, longer than 5 microm, was found to be 850 F/m(3) (according to the SI system the fiber concentration unit is (m(-3))) in the buildings covered with asbestos-cement sheets and 280 F/m(3) in the homes without asbestos-containing facades, located away from other asbestos sources. Although the laboratory and field measurements have been made by using the MIE Laser Fiber Monitor FM-7400 only, the obtained results indicate that the outdoor asbestos-cement building facades are significant sources of airborne fibers inside the dwellings in Upper Silesian towns. PMID:18692307

  7. Particle concentrations and number size distributions in the planetary boundary layer derived from airship based measurements

    NASA Astrophysics Data System (ADS)

    Tillmann, Ralf; Zhao, Defeng; Ehn, Mikael; Hofzumahaus, Andreas; Holland, Frank; Rohrer, Franz; Kiendler-Scharr, Astrid; Wahner, Andreas

    2014-05-01

    Atmospheric particles play a key role for regional and global climate due to their direct and indirect radiative forcing effects. The concentration and size of the particles are important variables to these effects. Within the continental planetary boundary layer (PBL) the particle number size distribution is influenced by meteorological parameters, local sinks and sources resulting in variable spatial distributions. However, measurements of particle number size distributions over a broad vertical range of the PBL are rare. The airship ZEPPELIN NT is an ideal platform to measure atmospheric aerosols on a regional scale within an altitude range up to 1000 m. For campaigns in the Netherlands, Northern Italy and South Finland in 2012 and 2013 the airship was deployed with a wide range of instruments, including measurements of different trace gases, short lived radicals, solar radiation, aerosols and meteorological parameters. Flights were carried out at different times of the day to investigate the influence of the diurnal evolution of the PBL on atmospheric trace gases and aerosols. During night and early morning hours the concentration and size distribution of atmospheric particles were found to be strongly influenced by the layered structure of the PBL, i.e. the nocturnal boundary layer and the residual layer. Within the residual layer particle concentrations stay relatively constant as this layer is decoupled from ground sources. The particles persist in the accumulation mode as expected for an aged aerosol. In the nocturnal boundary layer particle concentrations and size are more dynamic with higher concentrations than in the residual layer. A few hours after sunrise, the layered structure of the PBL intermixes. During daytime the PBL is well mixed and a negative concentration gradient with increasing height is observed. Several height profiles at different times of the day and at different locations in Europe were measured. The aerosol measurements will be

  8. Measurement of particle number and related pollutant concentrations in an urban area in South Brazil

    NASA Astrophysics Data System (ADS)

    Agudelo-Castañeda, D. M.; Teixeira, E. C.; Rolim, S. B. A.; Pereira, F. N.; Wiegand, F.

    2013-05-01

    The purpose of the present study was to analyze atmospheric particle number concentration at Sapucaia do Sul, in the Metropolitan Area of Porto Alegre, and associate it with the pollutants NO, NO2, and O3. Measurements were performed in two periods: August to October, in 2010 and 2011. We used the following equipment: the continuous particulate monitor (CPM), the chemiluminescent nitrogen oxide analyzer (AC32M), and the UV photometric ozone analyzer (O342M). Daily and hourly particle number concentrations in fractions PR1.0 (0.3-1.0 μm), PR2.5 (1.0-2.5 μm), and PR10 (2.5-10 μm), and concentrations of pollutants NO, NO2, NOx, and O3 were measured. These data were correlated with meteorological parameters such as wind speed, temperature, relative humidity, and solar radiation. The daily variation of OX (NO2 + O3) and its relation with NO2 were also established. The results obtained for daily particle number concentration (particles L-1) showed that the area of study had higher particle number of PR2.5 and PR1.0 size ranges, with values of 19.5 and 28.51 particles L-1, respectively. Differences in particle number concentrations in PR1 and PR2.5 size ranges were found between weekdays and weekends. The daily variation per hour of concentrations of particle number, NO, and NOx showed peaks during increased traffic flow in the morning and in the evening. NO2 showed peaks at different times, with the first peak (morning) 2 h after the peak of NO, and a second peak in the evening (19:00). This is due to the oxidation of NO and to the photolysis of NO3 formed overnight. Correlation analysis suggests that there may be a relationship between the fine and ultrafine particles and NO, probably indicating that they have similar sources, such as vehicular emissions. In addition, a possible relationship of solar radiation with fine particle number concentrations, as well as with O3 was also observed. The results, too, show an inverse relationship between particle number

  9. Variations in retention efficiency of bivalves to different concentrations and organic content of suspended particles

    NASA Astrophysics Data System (ADS)

    Zhang, Jihong; Fang, Jianguang; Liang, Xingming

    2010-01-01

    Retention efficiencies (RE) of scallop ( Chlamys farreri), oyster ( Crassostrea gigas) and mussel ( Mytilus edulis) in a flow-through system were measured to understand the short-term response to various particle and organic matter concentrations. By comparing the RE of C. farreri with that of C. gigas and M. edulis, we gained further knowledge on the feeding physiological characteristics of C. farreri and ascertained the possible cause of high summer mortalities of this species. The experimental feeding conditions included natural differences in the abundance and composition of suspended seston, as well as conditions in which seston abundance and composition were manipulated by adding natural silt or cultured microalgae. The results show that in natural sea water, the minimum particle size for maximal retention in M. edulis, C. gigas and C. farreri was approximately 4, 6, and 8 μm, respectively; the RE of 2-μm (equivalent spherical diameter) particles was 17%, 19%, and 8%, respectively; and the relative standardized RE was 58%, 49%, and 18%, respectively. In C. gigas and M. edulis, the minimal particle size for maximal retention did not change with food quality (organic content). C. farreri was more sensitive to fluctuations in particle concentration and organic content. With particle concentration increase, the minimal particle size for maximal retention in scallop shifted to large particles and the RE for 2-μm particle decreased from 8% in natural seawater to 1.6%-6% in silt-enriched groups. With organic content increase, the minimal particle size for maximal retention shifted from 8 to 5 μm in natural seawater.Variation in RE of C. farreri with food conditions and the relationship between lower RE and smaller particle size may hamper C. farreri from food taking due to the decrease in the size distribution of phytoplankton in Sungo Bay.

  10. Online Particle Size And Concentration Measurement In A Pressurized Coal Combustion Process

    SciTech Connect

    Schiel, A.; Umhauer, H.; Kasper, G.; Christmann, W.

    2002-09-19

    The energy industry has to face the demand for highly efficient coal combustion power plants in order to minimize the CO{sub 2} emissions. Efforts are made in new combustion processes, where coal powder is burned at a temperature of 1400 C and a pressure of 16 bars. The hot flue gas is used for a combined gas and steam turbine process. For that reason the flue gas has to be cleaned at the operating temperature and pressure. Limiting values for a secure operation of the turbine, with acceptable abrasion of the blades by impacting particles, are a mass concentration of c{sub M} {le}3 m g/m{sub N}{sup 3} at particle sizes smaller than 3 {micro}m . A granular bed filter is used to remove the gross of fine ash particles. But until now the separation of the submicron aerosol particles at high temperatures does not meet the mentioned specifications, and is still one of the most important open tasks. Regardless what kind of separation process will be implemented to remove fine ash particles, for investigations and control it is necessary to determine the particle concentration and size after the separation. The fact that the particle concentration after the purification is quite small and the size of the particles is less than 10 {micro}m means that gravimetric measurements are not suitable to record spontaneous changes due to the combustion process because of extended sampling times. Additionally a gravimetric measurement technique at operating conditions (T = 1400 C, p = 16 bars) is questionable, because particles can be lost by thermophoretic transport to the walls, also condensation of alkali species on the particle surfaces cannot be avoided (representativity). The single-particle-light-scattering size analysis is especially suited for measurements at low particle concentrations (< 10{sup 5} particles/m{sup 3}). With the counting technique used here, single particles are detected in situ while passing an optically defined measuring volume, which is placed in an iso

  11. Airborne particulate matter and spacecraft internal environments

    NASA Technical Reports Server (NTRS)

    Liu, Benjamin Y. H.; Rubow, Kenneth L.; Mcmurry, Peter H.; Kotz, Thomas J.; Russo, Dane

    1991-01-01

    Instrumentation, consisting of a Shuttle Particle Sampler (SPS) and a Shuttle Particle Monitor (SPM), has been developed to characterize the airborne particulate matter in the Space Shuttle cabin during orbital flight. The SPS size selectively collects particles in four size fractions (0-2.5, 2.5-10, 10-100, and greater than 100 microns) which are analyzed postflight for mass concentration and size distribution, elemental composition, and morphology. The SPM provides a continuous record of particle concentration through photometric light scattering. Measurements were performed onboard Columbia, OV-102, during the flight of STS-32 in January 1990. No significant changes were observed in the particle mass concentration, size distribution, or chemical composition in samples collected during flight-day 2 and flight-day 7. The total mass concentration was 56 microg/cu cm with approximately half of the particles larger than 100 microns. Elemental analysis showed that roughly 70 percent of the particles larger than 2.5 microns were carbonaceous with small amounts of other elements present. The SPM showed no temporal or spatial variation in particle mass concentration during the mission.

  12. Assessment and determinants of airborne bacterial and fungal concentrations in different indoor environments: Homes, child day-care centres, primary schools and elderly care centres

    NASA Astrophysics Data System (ADS)

    Madureira, Joana; Paciência, Inês; Rufo, João Cavaleiro; Pereira, Cristiana; Teixeira, João Paulo; de Oliveira Fernandes, Eduardo

    2015-05-01

    Until now the influence of risk factors resulting from exposure to biological agents in indoor air has been far less studied than outdoor pollution; therefore the uncertainty of health risks, and how to effectively prevent these, remains. This study aimed (i) to quantify airborne cultivable bacterial and fungal concentrations in four different types of indoor environment as well as to identify the recovered fungi; (ii) to assess the impact of outdoor bacterial and fungal concentrations on indoor air; (iii) to investigate the influence of carbon dioxide (CO2), temperature and relative humidity on bacterial and fungal concentrations; and (iv) to estimate bacterial and fungal dose rate for children (3-5 years old and 8-10 years old) in comparison with the elderly. Air samples were collected in 68 homes, 9 child day-care centres, 20 primary schools and 22 elderly care centres, in a total of 264 rooms with a microbiological air sampler and using tryptic soy agar and malt extract agar culture media for bacteria and fungi growth, respectively. For each building, one outdoor representative location were identified and simultaneously studied. The results showed that child day-care centres were the indoor microenvironment with the highest median bacterial and fungal concentrations (3870 CFU/m3 and 415 CFU/m3, respectively), whereas the lowest median concentrations were observed in elderly care centres (222 CFU/m3 and 180 CFU/m3, respectively). Indoor bacterial concentrations were significantly higher than outdoor concentrations (p < 0.05); whereas the indoor/outdoor ratios for the obtained fungal concentrations were approximately around the unit. Indoor CO2 levels were associated with the bacterial concentration, probably due to occupancy and insufficient ventilation. Penicillium and Cladosporium were the most frequently occurring fungi. Children's had two times higher dose rate to biological pollutants when compared to adult individuals. Thus, due to children

  13. A Miniature System for Separating Aerosol Particles and Measuring Mass Concentrations

    PubMed Central

    Liang, Dao; Shih, Wen-Pin; Chen, Chuin-Shan; Dai, Chi-An

    2010-01-01

    We designed and fabricated a new sensing system which consists of two virtual impactors and two quartz-crystal microbalance (QCM) sensors for measuring particle mass concentration and size distribution. The virtual impactors utilized different inertial forces of particles in air flow to classify different particle sizes. They were designed to classify particle diameter, d, into three different ranges: d < 2.28 μm, 2.28 μm ≤ d ≤ 3.20 μm, d > 3.20 μm. The QCM sensors were coated with a hydrogel, which was found to be a reliable adhesive for capturing aerosol particles. The QCM sensor coated with hydrogel was used to measure the mass loading of particles by utilizing its characteristic of resonant frequency shift. An integrated system has been demonstrated. PMID:22319317

  14. Airborne Coarse Mode Aerosol Measurements with the CAS-DPOL Instrument: Effects of Particle Shape and Refractive Index and Implications for Radiative Transfer Estimate

    NASA Astrophysics Data System (ADS)

    Sauer, D. N.; Weinzierl, B.; Gasteiger, J.; Spanu, A.; Freudenthaler, V.; Gross, S.

    2015-12-01

    Each year huge amounts of mineral dust are mobilized in deserts and arid regions of the world and transported over large distances forming thick elevated aerosol layers with a substantial fraction of coarse mode particles. Optical properties of mineral dust, including the absorptive refractive index of some components, cause a significant effect on the atmospheric radiative energy balance from optical to infrared wavelengths. The aerosol characteristics, in particular its coarse mode size distribution, are modified during long-range transport by aging and deposition processes. This also affects the aerosol optical properties and therefore the effect on the atmospheric radiative energy budget. In-situ measurements of aerosol microphysical properties are essential to characterize those effects in order to be implemented in global climate models in parametrized form. However, in-situ measurements of airborne coarse mode aerosols such as mineral dust and volcanic ash are challenging and the measurements are usually affected by substantial uncertainties. In this work we use airborne measurements of mineral dust from our optical light-scattering spectrometer CAS-DPOL during SALTRACE 2013 to discuss the analysis of such data. We cover the effects of varying refractive index and particle shapes and develop recommendations for the configuration of the CAS-DPOL for aerosol studies. We also present an inversion method to derive coarse mode size distributions from light-scattering probes for mixtures of non-spherical, absorbing aerosols. The size distributions retrieved from the in-situ measurements are then validated using an independent analysis with a combination of sun-photometer and lidar data. We apply these methods to investigate the Saharan mineral dust particle size distributions measured on both sides of the Atlantic Ocean and discuss the influence of aerosol aging on the atmospheric radiative energy budget. With this example we also assess how the uncertainties

  15. Optical tweezing electrophoresis of single biotinylated colloidal particles for avidin concentration measurement

    NASA Astrophysics Data System (ADS)

    Brans, Toon; Strubbe, Filip; Schreuer, Caspar; Neyts, Kristiaan; Beunis, Filip

    2015-06-01

    We present a novel approach for label-free concentration measurement of a specific protein in a solution. The technique combines optical tweezers and microelectrophoresis to establish the electrophoretic mobility of a single microparticle suspended in the solution. From this mobility measurement, the amount of adsorbed protein on the particle is derived. Using this method, we determine the concentration of avidin in a buffer solution. After calibration of the setup, which accounts for electro-osmotic flow in the measurement device, the mobilities of both bare and biotinylated microspheres are measured as a function of the avidin concentration in the mixture. Two types of surface adsorption are identified: the biotinylated particles show specific adsorption, resulting from the binding of avidin molecules with biotin, at low avidin concentrations (below 0.04 μg/ml) while at concentrations of several μg/ml non-specific on both types of particles is observed. These two adsorption mechanisms are incorporated in a theoretical model describing the relation between the measured mobility and the avidin concentration in the mixture. This model describes the electrophoretic mobility of these particles accurately over four orders of magnitude of the avidin concentration.

  16. Distribution of the concentration of heavy metals associated with the sediment particles accumulated on road surfaces.

    PubMed

    Zafra, C A; Temprano, J; Tejero, I

    2011-07-01

    The heavy metal pollution caused by road run-off water constitutes a problem in urban areas. The metallic load associated with road sediment must be determined in order to study its impact in drainage systems and receiving waters, and to perfect the design of prevention systems. This paper presents data regarding the sediment collected on road surfaces in the city of Torrelavega (northern Spain) during a period of 65 days (132 samples). Two sample types were collected: vacuum-dried samples and those swept up following vacuuming. The sediment loading (g m(-2)), particle size distribution (63-2800 microm) and heavy metal concentrations were determined. The data showed that the concentration of heavy metals tends to increase with the reduction in the particle diameter (exponential tendency). The concentrations ofPb, Zn, Cu, Cr, Ni, Cd, Fe, Mn and Co in the size fraction <63 microm were 350, 630, 124, 57, 56, 38, 3231, 374 and 51 mg kg(-1), respectively (average traffic density: 3800 vehicles day(-1)). By increasing the residence time of the sediment, the concentration increases, whereas the ratio of the concentration between the different size fractions decreases. The concentration across the road diminishes when the distance between the roadway and the sampling siteincreases; when the distance increases, the ratio between size fractions for heavy metal concentrations increases. Finally, the main sources of heavy metals are the particles detached by braking (brake pads) and tyre wear (rubber), and are associated with particle sizes <125 microm. PMID:21882553

  17. Optical determination of incipient soot particle concentrations in ethene laminar diffusion flames.

    SciTech Connect

    Gupta, S. B.; Santoro, R. J.

    1999-07-06

    Recent studies in premixed flames have shown the existence of ''transparent particles.'' These particles, 2 nm in size and in high number densities are considered to be a phase transitional between the gas phase PAH species and particulate soot. In the present study, various optical diagnostics were evaluated for measuring the concentration of these particles in situ, Through such evaluations, a technique using extinction at two wavelengths was found to be ideal. While employing such a technique, the volume fractions of these particles in an ethene laminar diffusion flame were measured. Low in the flame, these particles were found to be concentrated in the fuel rich core, while at higher locations, they could be found with appreciable volume fractions even in the soot laden regions. Having given due consideration for the errors due to uncertainties in the optical constants, we report the existence of these particles in an ethene flame with volume fractions comparable to those of soot. Also, similar measurements performed in a low sooting ethene/methanol flame show the concentration of these particles to be of the same order of magnitude as in a pure ethene flame.

  18. Spatio-temporal covariation of urban particle number concentration and ambient noise

    NASA Astrophysics Data System (ADS)

    Weber, Stephan

    Mobile measurements of ambient noise and particle number concentrations were carried out within an urban residential area in Essen, Germany, during summer 2008. A busy major road with a traffic intensity of about 44,000 vehicles per day was situated within the study area. The spatio-temporal distribution of noise and particles was closely coupled to road traffic on the major road. Total particle number concentrations in proximity to the main road were on average between 25,000 cm -3 and 35,000 cm -3 while sound levels reached 70-78 dB(A). These estimates were more than double-fold (factor 2.4) in comparison to the urban residential background. At a 50 m distance off the road particle number concentrations were decaying to about 50% of the initial value. The measurements were characterised by close spatial correlation between total particle number concentration and ambient noise with correlation coefficients of up to r = 0.74. However, during one measurement day coupling between both quantities was weak due to higher turbulent mixing within the canopy layer and a change in ambient wind directions. Enhanced dilution of particle emission from road traffic by turbulent mixing and 'decoupling' from the influence of road traffic are believed to be responsible.

  19. Investigation of particle inertial migration in high particle concentration suspension flow by multi-electrodes sensing and Eulerian-Lagrangian simulation in a square microchannel.

    PubMed

    Zhao, Tong; Yao, Jiafeng; Liu, Kai; Takei, Masahiro

    2016-03-01

    The inertial migration of neutrally buoyant spherical particles in high particle concentration (αpi  > 3%) suspension flow in a square microchannel was investigated by means of the multi-electrodes sensing method which broke through the limitation of conventional optical measurement techniques in the high particle concentration suspensions due to interference from the large particle numbers. Based on the measured particle concentrations near the wall and at the corner of the square microchannel, particle cross-sectional migration ratios are calculated to quantitatively estimate the migration degree. As a result, particle migration to four stable equilibrium positions near the centre of each face of the square microchannel is found only in the cases of low initial particle concentration up to 5.0 v/v%, while the migration phenomenon becomes partial as the initial particle concentration achieves 10.0 v/v% and disappears in the cases of the initial particle concentration αpi  ≥ 15%. In order to clarify the influential mechanism of particle-particle interaction on particle migration, an Eulerian-Lagrangian numerical model was proposed by employing the Lennard-Jones potential as the inter-particle potential, while the inertial lift coefficient is calculated by a pre-processed semi-analytical simulation. Moreover, based on the experimental and simulation results, a dimensionless number named migration index was proposed to evaluate the influence of the initial particle concentration on the particle migration phenomenon. The migration index less than 0.1 is found to denote obvious particle inertial migration, while a larger migration index denotes the absence of it. This index is helpful for estimation of the maximum initial particle concentration for the design of inertial microfluidic devices. PMID:27158288

  20. In situ formation and spatial variability of particle number concentration in a European megacity

    NASA Astrophysics Data System (ADS)

    Pikridas, M.; Sciare, J.; Freutel, F.; Crumeyrolle, S.; von der Weiden-Reinmüller, S.-L.; Borbon, A.; Schwarzenboeck, A.; Merkel, M.; Crippa, M.; Kostenidou, E.; Psichoudaki, M.; Hildebrandt, L.; Engelhart, G. J.; Petäjä, T.; Prévôt, A. S. H.; Drewnick, F.; Baltensperger, U.; Wiedensohler, A.; Kulmala, M.; Beekmann, M.; Pandis, S. N.

    2015-09-01

    Ambient particle number size distributions were measured in Paris, France, during summer (1-31 July 2009) and winter (15 January to 15 February 2010) at three fixed ground sites and using two mobile laboratories and one airplane. The campaigns were part of the Megacities: Emissions, urban, regional and Global Atmospheric POLlution and climate effects, and Integrated tools for assessment and mitigation (MEGAPOLI) project. New particle formation (NPF) was observed only during summer on approximately 50 % of the campaign days, assisted by the low condensation sink (about 10.7 ± 5.9 × 10-3 s-1). NPF events inside the Paris plume were also observed at 600 m altitude onboard an aircraft simultaneously with regional events identified on the ground. Increased particle number concentrations were measured aloft also outside of the Paris plume at the same altitude, and were attributed to NPF. The Paris plume was identified, based on increased particle number and black carbon concentration, up to 200 km away from the Paris center during summer. The number concentration of particles with diameters exceeding 2.5 nm measured on the surface at the Paris center was on average 6.9 ± 8.7 × 104 and 12.1 ± 8.6 × 104 cm-3 during summer and winter, respectively, and was found to decrease exponentially with distance from Paris. However, further than 30 km from the city center, the particle number concentration at the surface was similar during both campaigns. During summer, one suburban site in the NE was not significantly affected by Paris emissions due to higher background number concentrations, while the particle number concentration at the second suburban site in the SW increased by a factor of 3 when it was downwind of Paris.

  1. Characterization of Airborne Nanoparticle Loss in Sampling Tubing.

    PubMed

    Tsai, Candace Su-Jung

    2015-01-01

    Airborne nanoparticle release has been studied extensively lately using a variety of instruments and nanoparticle loss data for the instrument sampling tubes were required. This study used real-time measurements to characterize particle losses. Particle concentrations were measured by Fast Mobility Particle Sizer (FMPS). Electrically conductive and Tygon sampling tubes 7.7 mm I.D. and 2.0, 4.9, 7.0, and 8.4 m long, were used to analyze particle losses. Two different sources of nearly steady-state particles-atmospheric nanoparticles (maximum concentration of 4,000-6,000 particle/cm(3)) and nebulizer-generated salt aerosols (maximum concentration of 14,000-16,000 particle/cm(3))-were utilized. For all test conditions, a reduction in particle number concentration was observed and found to be proportional to tube length for particle diameter (dp) less than 40 nm. A maximum loss up to 30% was found for the longest tube length (8.4 m) at particle size of approximately 8 nm. For particles from 40 to 400 nm, the losses were less than 3%. Measured particle losses were greater than predicted by theory for the smallest particles. The two types of tubing showed similar particle losses for both test aerosols. Particle losses were low for dp greater than 40 nm, and for all particle sizes when the tube length was less than 2 m. PMID:25746064

  2. Determination of concentration of charged particles in various regions of thunderstorms

    NASA Astrophysics Data System (ADS)

    Detwiler, A. G.; Mo, Q.

    2015-12-01

    During the Severe Thunderstorm Precipitation and Electrification Study in 2000, data on hydrometeor sizes and charges were obtained in thunderstorms using an optical array probe modified by the New Mexico Institute of Mining and Technology and mounted on the South Dakota School of Mines and Technology armored T-28 research aircraft. Analysis yielded quantitative observations of hydrometeor size and charge data in selected regions of storms with relatively low concentrations of charged particles. In most regions hydrometeor concentrations were so high that there were multiple charged particles in the probe sample volume at the same time and quantitative charge analysis was not possible. While it is impossible to reliably determine individual particle charges in these high concentration regions, we can use Poisson statistics to estimate the total number concentration of charged particles based on the fraction of records with just one particle in them. We compare these number concentrations for different thunderstorm regions, including updrafts, flanking cells, core precipitation regions, and trailing stratiform regions, at approximately the -10 C level, in several thunderstorms. We will discuss the implications of these results for understanding charge-separation processes in thunderstorms.

  3. Ultrafine particles near a roadway intersection: origin and apportionment of fast changes in concentration.

    PubMed

    Klems, Joseph P; Pennington, M Ross; Zordan, Christopher A; Johnston, Murray V

    2010-10-15

    A wavelet-based algorithm was implemented to separate the high frequency portion of ambient nanoparticle measurements taken during the summer and winter of 2009 in Wilmington, Delaware. These measurements included both number concentration and size distributions recorded once every second by a condensation particle counter (CPC) and a fast mobility particle sizer (FMPS). The high frequency portion of the signal, consisting of a series of abrupt spikes in number concentration that varied in length from a few seconds to tens of seconds, accounted for 6-35% of the daily ambient number concentration with hourly contributions sometimes greater than 50%. When the data were weighted by particle volume, this portion of the signal contributed an average of 20% to the daily PM(0.1) concentration. Particle concentration spikes were preferentially observed from locations surrounding the measurement site where motor vehicles accelerate after a red traffic light turns green. As the distance or transit time from emission to sampling increased, the size distribution shifted to larger particle diameters. PMID:20843065

  4. Vertical wind retrieved by airborne lidar and analysis of island induced gravity waves in combination with numerical models and in situ particle measurements

    NASA Astrophysics Data System (ADS)

    Chouza, Fernando; Reitebuch, Oliver; Jähn, Michael; Rahm, Stephan; Weinzierl, Bernadett

    2016-04-01

    This study presents the analysis of island induced gravity waves observed by an airborne Doppler wind lidar (DWL) during SALTRACE. First, the instrumental corrections required for the retrieval of high spatial resolution vertical wind measurements from an airborne DWL are presented and the measurement accuracy estimated by means of two different methods. The estimated systematic error is below -0.05 m s-1 for the selected case of study, while the random error lies between 0.1 and 0.16 m s-1 depending on the estimation method. Then, the presented method is applied to two measurement flights during which the presence of island induced gravity waves was detected. The first case corresponds to a research flight conducted on 17 June 2013 in the Cabo Verde islands region, while the second case corresponds to a measurement flight on 26 June 2013 in the Barbados region. The presence of trapped lee waves predicted by the calculated Scorer parameter profiles was confirmed by the lidar and in situ observations. The DWL measurements are used in combination with in situ wind and particle number density measurements, large-eddy simulations (LES), and wavelet analysis to determine the main characteristics of the observed island induced trapped waves.

  5. Inverse dependency of particle residence times in ponds to the concentration of phosphate, the limiting nutrient.

    PubMed

    Roberts, Kimberly A; Santschi, Peter H

    2004-01-01

    234Th, a commonly used short-lived particle-reactive tracer in marine systems, was measured in three different holding pond series at the Rocky Flats Environmental Technology Site (RFETS), Colorado, along with its parent nuclide 238U, to determine steady-state residence times of particle-reactive actinides such as Pu, and of particles. Series B ponds, which received industrial effluent that includes ortho-phosphate (PO4) and actinides, differed from series A and C ponds, which did not. This difference was also evident in the calculated particle residence times, which were <1 day for the ponds B4 and B5, where PO4 concentrations