A Prototype Flight-Deck Airflow Hazard Visualization System
NASA Technical Reports Server (NTRS)
Aragon, Cecilia R.
2004-01-01
Airflow hazards such as turbulence, vortices, or low-level wind shear can pose a threat to landing aircraft and are especially dangerous to helicopters. Because pilots usually cannot see airflow, they may be unaware of the extent of the hazard. We have developed a prototype airflow hazard visual display for use in helicopter cockpits to alleviate this problem. We report on the results of a preliminary usability study of our airflow hazard visualization system in helicopter-shipboard operations.
Airflow Hazard Visualization for Helicopter Pilots: Flight Simulation Study Results
NASA Technical Reports Server (NTRS)
Aragon, Cecilia R.; Long, Kurtis R.
2005-01-01
Airflow hazards such as vortices or low level wind shear have been identified as a primary contributing factor in many helicopter accidents. US Navy ships generate airwakes over their decks, creating potentially hazardous conditions for shipboard rotorcraft launch and recovery. Recent sensor developments may enable the delivery of airwake data to the cockpit, where visualizing the hazard data may improve safety and possibly extend ship/helicopter operational envelopes. A prototype flight-deck airflow hazard visualization system was implemented on a high-fidelity rotorcraft flight dynamics simulator. Experienced helicopter pilots, including pilots from all five branches of the military, participated in a usability study of the system. Data was collected both objectively from the simulator and subjectively from post-test questionnaires. Results of the data analysis are presented, demonstrating a reduction in crash rate and other trends that illustrate the potential of airflow hazard visualization to improve flight safety.
Data Visualization of Invisible Airflow Hazards During Helicopter Takeoff and Landing Operations
NASA Technical Reports Server (NTRS)
Aragon, Cecilia R.
2004-01-01
Many aircraft accidents each year are caused by encounters with unseen airflow hazards near the ground such as vortices, downdrafts, wind shear, microbursts, or other turbulence. While such hazards frequently pose problems to fixed-wing airplanes, they are especially dangerous to helicopters, which often have to operate in confined spaces and under operationally stressful conditions. We are developing flight-deck visualizations of airflow hazards during helicopter takeoff and landing operations, and are evaluating their effectiveness with usability studies. Our hope is.that this work will lead to the production of an airflow hazard detection system for pilots that will save lives.
Usability Evaluation of a Flight-Deck Airflow Hazard Visualization System
NASA Technical Reports Server (NTRS)
Aragon, Cecilia R.
2004-01-01
Many aircraft accidents each year are caused by encounters with unseen airflow hazards near the ground, such as vortices, downdrafts, low level wind shear, microbursts, or turbulence from surrounding vegetation or structures near the landing site. These hazards can be dangerous even to airliners; there have been hundreds of fatalities in the United States in the last two decades attributable to airliner encounters with microbursts and low level wind shear alone. However, helicopters are especially vulnerable to airflow hazards because they often have to operate in confined spaces and under operationally stressful conditions (such as emergency search and rescue, military or shipboard operations). Providing helicopter pilots with an augmented-reality display visualizing local airflow hazards may be of significant benefit. However, the form such a visualization might take, and whether it does indeed provide a benefit, had not been studied before our experiment. We recruited experienced military and civilian helicopter pilots for a preliminary usability study to evaluate a prototype augmented-reality visualization system. The study had two goals: first, to assess the efficacy of presenting airflow data in flight; and second, to obtain expert feedback on sample presentations of hazard indicators to refine our design choices. The study addressed the optimal way to provide critical safety information to the pilot, what level of detail to provide, whether to display specific aerodynamic causes or potential effects only, and how to safely and effectively shift the locus of attention during a high-workload task. Three-dimensional visual cues, with varying shape, color, transparency, texture, depth cueing, and use of motion, depicting regions of hazardous airflow, were developed and presented to the pilots. The study results indicated that such a visualization system could be of significant value in improving safety during critical takeoff and landing operations, and also gave clear indications of the best design choices in producing the hazard visual cues.
Improving Aviation Safety with information Visualization: A Flight Simulation Study
NASA Technical Reports Server (NTRS)
Aragon, Cecilia R.; Hearst, Marti
2005-01-01
Many aircraft accidents each year are caused by encounters with invisible airflow hazards. Recent advances in aviation sensor technology offer the potential for aircraft-based sensors that can gather large amounts of airflow velocity data in real-time. With this influx of data comes the need to study how best to present it to the pilot - a cognitively overloaded user focused on a primary task other than that of information visualization. In this paper, we present the results of a usability study of an airflow hazard visualization system that significantly reduced the crash rate among experienced helicopter pilots flying a high fidelity, aerodynamically realistic fixed-base rotorcraft flight simulator into hazardous conditions. We focus on one particular aviation application, but the results may be relevant to user interfaces in other operationally stressful environments.
Visualization of airflow growing soap bubbles
NASA Astrophysics Data System (ADS)
Al Rahbi, Hamood; Bock, Matthew; Ryu, Sangjin
2016-11-01
Visualizing airflow inside growing soap bubbles can answer questions regarding the fluid dynamics of soap bubble blowing, which is a model system for flows with a gas-liquid-gas interface. Also, understanding the soap bubble blowing process is practical because it can contribute to controlling industrial processes similar to soap bubble blowing. In this study, we visualized airflow which grows soap bubbles using the smoke wire technique to understand how airflow blows soap bubbles. The soap bubble blower setup was built to mimic the human blowing process of soap bubbles, which consists of a blower, a nozzle and a bubble ring. The smoke wire was placed between the nozzle and the bubble ring, and smoke-visualized airflow was captured using a high speed camera. Our visualization shows how air jet flows into the growing soap bubble on the ring and how the airflow interacts with the soap film of growing bubble.
Using Visualization in Cockpit Decision Support Systems
NASA Technical Reports Server (NTRS)
Aragon, Cecilia R.
2005-01-01
In order to safely operate their aircraft, pilots must make rapid decisions based on integrating and processing large amounts of heterogeneous information. Visual displays are often the most efficient method of presenting safety-critical data to pilots in real time. However, care must be taken to ensure the pilot is provided with the appropriate amount of information to make effective decisions and not become cognitively overloaded. The results of two usability studies of a prototype airflow hazard visualization cockpit decision support system are summarized. The studies demonstrate that such a system significantly improves the performance of helicopter pilots landing under turbulent conditions. Based on these results, design principles and implications for cockpit decision support systems using visualization are presented.
Real-time visualization and analysis of airflow field by use of digital holography
NASA Astrophysics Data System (ADS)
Di, Jianglei; Wu, Bingjing; Chen, Xin; Liu, Junjiang; Wang, Jun; Zhao, Jianlin
2013-04-01
The measurement and analysis of airflow field is very important in fluid dynamics. For airflow, smoke particles can be added to visually observe the turbulence phenomena by particle tracking technology, but the effect of smoke particles to follow the high speed airflow will reduce the measurement accuracy. In recent years, with the advantage of non-contact, nondestructive, fast and full-field measurement, digital holography has been widely applied in many fields, such as deformation and vibration analysis, particle characterization, refractive index measurement, and so on. In this paper, we present a method to measure the airflow field by use of digital holography. A small wind tunnel model made of acrylic glass is built to control the velocity and direction of airflow. Different shapes of samples such as aircraft wing and cylinder are placed in the wind tunnel model to produce different forms of flow field. With a Mach-Zehnder interferometer setup, a series of digital holograms carrying the information of airflow filed distributions in different states are recorded by CCD camera and corresponding holographic images are numerically reconstructed from the holograms by computer. Then we can conveniently obtain the velocity or pressure information of the airflow deduced from the quantitative phase information of holographic images and visually display the airflow filed and its evolution in the form of a movie. The theory and experiment results show that digital holography is a robust and feasible approach for real-time visualization and analysis of airflow field.
Fabrication of highly oriented nanoporous fibers via airflow bubble-spinning
NASA Astrophysics Data System (ADS)
Liu, Fujuan; Li, Shaokai; Fang, Yue; Zheng, Fangfang; Li, Junhua; He, Jihuan
2017-11-01
Highly oriented Poly(lactic acid) (PLA) nanofibers with nanoporous structures has been successfully fabricated via airflow bubble-spinning without electrostatic hazard. In this work, the volatile solvent was necessary for preparing the nanoporous fiber, which was attributed to the competition between phase separation and solvent evaporation. The interconnected porous structures were affected by the processing variables of solution concentration, airflow temperature, collecting distance and relative humidity (RH). Besides, the rheological properties of solutions were studied and the highly oriented PLA nanofibers with nanoporous structure were also completely characterized using scanning electron microscope (SEM). This study provided a novel technique that successfully gets rid of the potential safety hazards caused by unexpected static to prepare highly oriented nanoporous fibers, which would demonstrate an impressive prospect for the fields of adsorption and filtration.
On the Uses of Full-Scale Schlieren Flow Visualization
NASA Astrophysics Data System (ADS)
Settles, G. S.; Miller, J. D.; Dodson-Dreibelbis, L. J.
2000-11-01
A lens-and-grid-type schlieren system using a very large grid as a light source was described at earlier APS/DFD meetings. With a field-of-view of 2.3x2.9 m (7.5x9.5 feet), it is the largest indoor schlieren system in the world. Still and video examples of several full-scale airflows and heat-transfer problems visualized thus far will be shown. These include: heating and ventilation airflows, flows due to appliances and equipment, the thermal plumes of people, the aerodynamics of an explosive trace detection portal, gas leak detection, shock wave motion associated with aviation security problems, and heat transfer from live crops. Planned future projects include visualizing fume-hood and grocery display freezer airflows and studying the dispersion of insect repellent plumes at full scale.
NASA Astrophysics Data System (ADS)
Tutak, Magdalena; Brodny, Jarosław
2018-01-01
Hazard of endogenous fires is one of the basic and common presented occupational safety hazards in coal mine in Poland and in the world. This hazard means possibility of coal self-ignition as the result of its self-heating process in mining heading or its surrounding. In underground coal-mining during ventilating of operating longwalls takes place migration of parts of airflow to goaf with caving. In a case when in these goaf a coal susceptible to self-ignition occurs, then the airflow through these goaf may influence on formation of favorable conditions for coal oxidation and subsequently to its self-heating and self-ignition. Endogenous fire formed in such conditions can pose a serious hazards for the crew and for continuity of operation of mining plant. From the practical point of view a very significant meaning has determination of the zone in the goaf with caving, in which necessary conditions for occurence of endogenous fire are fulfilled. In the real conditions determination of such a zone is practically impossible. The main aim of the analysis was to determine the impact of type of the roof rocks forming the goaf on the location and range of endogenous fires particular hazard zone by in these goaf. For determined mining-geological conditions, the critical value of velocity of airflow and oxygen concentration in goaf, conditioning initiation of coal oxidation process were determined.
Lee, Heow Peuh; Gordon, Bruce R.
2012-01-01
During the past decades, numerous computational fluid dynamics (CFD) studies, constructed from CT or MRI images, have simulated human nasal models. As compared to rhinomanometry and acoustic rhinometry, which provide quantitative information only of nasal airflow, resistance, and cross sectional areas, CFD enables additional measurements of airflow passing through the nasal cavity that help visualize the physiologic impact of alterations in intranasal structures. Therefore, it becomes possible to quantitatively measure, and visually appreciate, the airflow pattern (laminar or turbulent), velocity, pressure, wall shear stress, particle deposition, and temperature changes at different flow rates, in different parts of the nasal cavity. The effects of both existing anatomical factors, as well as post-operative changes, can be assessed. With recent improvements in CFD technology and computing power, there is a promising future for CFD to become a useful tool in planning, predicting, and evaluating outcomes of nasal surgery. This review discusses the possibilities and potential impacts, as well as technical limitations, of using CFD simulation to better understand nasal airflow physiology. PMID:23205221
Effects of Forced Air Warming on Airflow around the Operating Table.
Shirozu, Kazuhiro; Kai, Tetsuya; Setoguchi, Hidekazu; Ayagaki, Nobuyasu; Hoka, Sumio
2018-01-01
Forced air warming systems are used to maintain body temperature during surgery. Benefits of forced air warming have been established, but the possibility that it may disturb the operating room environment and contribute to surgical site contamination is debated. The direction and speed of forced air warming airflow and the influence of laminar airflow in the operating room have not been reported. In one institutional operating room, we examined changes in airflow speed and direction from a lower-body forced air warming device with sterile drapes mimicking abdominal surgery or total knee arthroplasty, and effects of laminar airflow, using a three-dimensional ultrasonic anemometer. Airflow from forced air warming and effects of laminar airflow were visualized using special smoke and laser light. Forced air warming caused upward airflow (39 cm/s) in the patient head area and a unidirectional convection flow (9 to 14 cm/s) along the ceiling from head to foot. No convection flows were observed around the sides of the operating table. Downward laminar airflow of approximately 40 cm/s counteracted the upward airflow caused by forced air warming and formed downward airflow at 36 to 45 cm/s. Downward airflows (34 to 56 cm/s) flowing diagonally away from the operating table were detected at operating table height in both sides. Airflow caused by forced air warming is well counteracted by downward laminar airflow from the ceiling. Thus it would be less likely to cause surgical field contamination in the presence of sufficient laminar airflow.
Airflow resistance and CO2 rebreathing properties of anti-asphyxia pillows designed for epilepsy.
Catcheside, Peter G; Mohtar, Aaron A; Reynolds, Karen J
2014-06-01
Seizure related unconscious face-down positioning could contribute to sudden unexpected death in epilepsy via asphyxia. Low airflow resistance lattice foam pillows have been advocated for this group. However, data to support this approach remain lacking, and low airflow resistance per se may not negate asphyxia risk from expired gas rebreathing. This study was designed to compare the airflow resistance and CO2 rebreathing properties of lattice vs conventional pillows. Airflow resistance and inspired CO2 levels during replicate 10 min periods of simulated adult ventilation and CO2 rebreathing were compared between cotton, latex and two lattice pillows designed for use in epilepsy (one commercially available, one prototype). Kaplan-Meier and Cox regression analyses were used to examine the hazard of exceeding 10% inspired CO2 within 10-min of rebreathing. Inspiratory resistance was significantly lower in the commercially available and prototype lattice compared to cotton and latex pillows (mean±SD; 3.2±0.8, 2.6±0.4, 26.1±3.5, 4.6±0.4 cm H2O l(-1)s respectively at 0.2l s(-1)). During simulated rebreathing, inspired CO2 exceeded 10% within 2 min with cotton and latex pillows, compared to an upper asymptote around 8-9% at 10 min with lattice pillows. The hazard of exceeding 10% inspired CO2 was therefore markedly reduced with lattice compared to cotton and latex pillows (hazard ratio vs cotton pillow; commercial 0.04 [0.01-0.18], prototype 0.08 [0.02-0.26], latex 0.79 [0.33-1.87]). Conventional pillows can rapidly accumulate potentially life-threatening CO2 levels during simulated rebreathing. Lattice pillows appear to reduce asphyxia risk but accumulated CO2 may still reach levels threatening to health and survival. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Asbestos penetration test system for clothing materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradley, O.D.; Stampfer, J.F.; Sandoval, A.N.
1997-04-01
For hazardous work such as asbestos abatement, there is a need to assess protective clothing fabrics and seam constructions to assure an adequate barrier against hazardous material. The penetration of aerosols through fabrics usually is measured by challenging fabric samples with an aerosol stream at a constant specified airflow. To produce the specified airflow, pressure differentials across the samples often are higher than exist in a work environment. This higher airflow results in higher aerosol velocities through the fabric and, possibly, measured penetration values not representative of those actually experienced in the field. The objective of the reported work wasmore » to develop a test method that does not require these higher airflows. The authors have designed and fabricated a new system that tests fabric samples under a low, constant, specified pressure differential across the samples. This differential is adjustable from tenths of a mm Water Gauge (hundredths of an in WG) to over 25-mm WG (1-in WG). The system operates at a pressure slightly lower than its surroundings. Although designed primarily for asbestos, the system is equally applicable to the testing of other aerosols by changing the aerosol generator and detector. Through simple modification of the sample holders, the test apparatus would be capable of evaluating seam and closure constructions.« less
... should be in a room with good airflow Work Safely If you find a spill, treat it like ... Updated April 10, 2017. Accessed February 21, 2018. Occupational Safety and Health Administration website. Healthcare. www.osha.gov/ ...
Computational and experimental study of airflow around a fan powered UVGI lamp
NASA Astrophysics Data System (ADS)
Kaligotla, Srikar; Tavakoli, Behtash; Glauser, Mark; Ahmadi, Goodarz
2011-11-01
The quality of indoor air environment is very important for improving the health of occupants and reducing personal exposure to hazardous pollutants. An effective way of controlling air quality is by eliminating the airborne bacteria and viruses or by reducing their emissions. Ultraviolet Germicidal Irradiation (UVGI) lamps can effectively reduce these bio-contaminants in an indoor environment, but the efficiency of these systems depends on airflow in and around the device. UVGI lamps would not be as effective in stagnant environments as they would be when the moving air brings the bio-contaminant in their irradiation region. Introducing a fan into the UVGI system would augment the efficiency of the system's kill rate. Airflows in ventilated spaces are quite complex due to the vast range of length and velocity scales. The purpose of this research is to study these complex airflows using CFD techniques and validate computational model with airflow measurements around the device using Particle Image Velocimetry measurements. The experimental results including mean velocities, length scales and RMS values of fluctuating velocities are used in the CFD validation. Comparison of these data at different locations around the device with the CFD model predictions are performed and good agreement was observed.
Spacecraft Minimum Allowable Concentrations: Determination, Application, and Contingency Situations
NASA Technical Reports Server (NTRS)
Marshburn, Thomas H.; Dawson, David L. (Technical Monitor)
1999-01-01
This document is an outline of a presentation about the determination of minimum allowable concentrations in spacecraft. The presentation reviews the type of toxins and mechanisms to determine the acceptable concentrations of these toxic substances. The considerations for the unique situation that spaceflight entails including zero gravity, and the intense scrutiny are reviewed. The current measurement hardware is reviewed. The spacecraft atmospheres on the Shuttle, airflow, the Space Station and the EMU in respect to airflow, pressure, constituents are also summarized. Contingency situations and potential hazards are also discussed.
The simulation of air recirculation and fire/explosion phenomena within a semiconductor factory.
I, Yet-Pole; Chiu, Yi-Long; Wu, Shi-Jen
2009-04-30
The semiconductor industry is the collection of capital-intensive firms that employ a variety of hazardous chemicals and engage in the design and fabrication of semiconductor devices. Owing to its processing characteristics, the fully confined structure of the fabrication area (fab) and the vertical airflow ventilation design restrict the applications of traditional consequence analysis techniques that are commonly used in other industries. The adverse situation also limits the advancement of a fire/explosion prevention design for the industry. In this research, a realistic model of a semiconductor factory with a fab, sub-fabrication area, supply air plenum, and return air plenum structures was constructed and the computational fluid dynamics algorithm was employed to simulate the possible fire/explosion range and its severity. The semiconductor factory has fan module units with high efficiency particulate air filters that can keep the airflow uniform within the cleanroom. This condition was modeled by 25 fans, three layers of porous ceiling, and one layer of porous floor. The obtained results predicted very well the real airflow pattern in the semiconductor factory. Different released gases, leak locations, and leak rates were applied to investigate their influence on the hazard range and severity. Common mitigation measures such as a water spray system and a pressure relief panel were also provided to study their potential effectiveness to relieve thermal radiation and overpressure hazards within a fab. The semiconductor industry can use this simulation procedure as a reference on how to implement a consequence analysis for a flammable gas release accident within an air recirculation cleanroom.
NASA Astrophysics Data System (ADS)
Leger, L.; Sellam, M.; Barbosa, E.; Depussay, E.
2013-06-01
The use of plasma actuators for flow control has received considerable attention in recent years. This kind of device seems to be an appropriate means of raising abilities in flow control thanks to total electric control, no moving parts and a fast response time. The experimental work presented here shows, firstly, the non-intrusive character of the visualization of the density field of an airflow around a cylinder obtained using a plasma luminescence technique. Experiments are made in a continuous supersonic wind tunnel. The static pressure in the flow is 8 Pa, the mean free path is about 0.3 mm and the airflow velocity is 510 m s-1. Pressure measurements obtained by means of glass Pitot tube without the visualization discharge are proposed. Measured and simulated pressure profiles are in good agreement in the region near the cylinder. There is good correlation between numerical simulations of the supersonic flow field, analytical model predictions and experimental flow visualizations obtained by a plasma luminescence technique. Consequently, we show that the plasma luminescence technique is non-intrusive. Secondly, the effect of a dc discharge on a supersonic rarefied air flow around a cylinder is studied. An electrode is flush mounted on the cylinder. Stagnation pressure profiles are examined for different electrode positions on the cylinder. A shock wave modification depending on the electrode location is observed. The discharge placed at the upstream stagnation point induces an upstream shift of the bow shock, whereas a modification of the shock wave shape is observed when it is placed at 45° or 90°.
1/48-scale model of an F-18 aircraft in Flow Visualization Facility (FVF)
NASA Technical Reports Server (NTRS)
1985-01-01
This image shows a plastic 1/48-scale model of an F-18 aircraft inside the 'Water Tunnel' more formally known as the NASA Dryden Flow Visualization Facility. Water is pumped through the tunnel in the direction of normal airflow over the aircraft; then, colored dyes are pumped through tubes with needle valves. The dyes flow back along the airframe and over the airfoils highlighting their aerodynamic characteristics. The aircraft can also be moved through its pitch axis to observe airflow disruptions while simulating actual flight at high angles of attack. The Water Tunnel at NASA's Dryden Flight Research Center, Edwards, CA, became operational in 1983 when Dryden was a Flight Research Facility under the management of the Ames Research Center in Mountain View, CA. As a medium for visualizing fluid flow, water has played a significant role. Its use dates back to Leonardo da Vinci (1452-1519), the Renaissance Italian engineer, architect, painter, and sculptor. In more recent times, water tunnels have assisted the study of complex flows and flow-field interactions on aircraft shapes that generate strong vortex flows. Flow visualization in water tunnels assists in determining the strength of vortices, their location, and possible methods of controlling them. The design of the Dryden Water Tunnel imitated that of the Northrop Corporation's tunnel in Hawthorne, CA. Called the Flow Visualization Facility, the Dryden tunnel was built to assist researchers in understanding the aerodynamics of aircraft configured in such a way that they create strong vortex flows, particularly at high angles of attack. The tunnel provides results that compare well with data from aircraft in actual flight in another fluid-air. Other uses of the tunnel have included study of how such flight hardware as antennas, probes, pylons, parachutes, and experimental fixtures affect airflow. The facility has also been helpful in finding the best locations for emitting smoke from flight vehicles for flow visualization.
1/48-scale model of an F-18 aircraft in Flow Visualization Facility (FVF)
NASA Technical Reports Server (NTRS)
1980-01-01
This short movie clip shows a plastic 1/48-scale model of an F-18 aircraft inside the 'Water Tunnel' more formally known as the NASA Dryden Flow Visualization Facility. Water is pumped through the tunnel in the direction of normal airflow over the aircraft; then, colored dyes are pumped through tubes with needle valves. The dyes flow back along the airframe and over the airfoils highlighting their aerodynamic characteristics. The aircraft can also be moved through its pitch axis to observe airflow disruptions while simulating actual flight at high angles of attack. The Water Tunnel at NASA's Dryden Flight Research Center, Edwards, CA, became operational in 1983 when Dryden was a Flight Research Facility under the management of the Ames Research Center in Mountain View, CA. As a medium for visualizing fluid flow, water has played a significant role. Its use dates back to Leonardo da Vinci (1452-1519), the Renaissance Italian engineer, architect, painter, and sculptor. In more recent times, water tunnels have assisted the study of complex flows and flow-field interactions on aircraft shapes that generate strong vortex flows. Flow visualization in water tunnels assists in determining the strength of vortices, their location, and possible methods of controlling them. The design of the Dryden Water Tunnel imitated that of the Northrop Corporation's tunnel in Hawthorne, CA. Called the Flow Visualization Facility, the Dryden tunnel was built to assist researchers in understanding the aerodynamics of aircraft configured in such a way that they create strong vortex flows, particularly at high angles of attack. The tunnel provides results that compare well with data from aircraft in actual flight in another fluid-air. Other uses of the tunnel have included study of how such flight hardware as antennas, probes, pylons, parachutes, and experimental fixtures affect airflow. The facility has also been helpful in finding the best locations for emitting smoke from flight vehicles for flow visualization.
Below, Harald; Ryll, Sylvia; Empen, Klaus; Dornquast, Tina; Felix, Stefan; Rosenau, Heike; Kramer, Sebastian; Kramer, Axel
2010-09-21
In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air.Under the given conditions, disinfection of all surfaces including all furniture and equipment after the last operation and subsequent draping of furniture and all equipment that could not be removed from the room with sterile surgical drapes improved the indoor room air quality from cleanroom class C to cleanroom class B. This also allows procedures with elevated requirements to be performed in room class 1b.
Visual Aid to Demonstrate Change of State and Gas Pressure with Temperature
ERIC Educational Resources Information Center
Ghaffari, Shahrokh
2011-01-01
Demonstrations are used in chemistry lectures to improve conceptual understanding by direct observation. The visual aid described here is designed to demonstrate the change in state of matter with the change of temperature and the change of pressure with temperature. Temperature is presented by the rate of airflow and pressure is presented by…
Off-surface infrared flow visualization
NASA Technical Reports Server (NTRS)
Manuel, Gregory S. (Inventor); Obara, Clifford J. (Inventor); Daryabeigi, Kamran (Inventor); Alderfer, David W. (Inventor)
1993-01-01
A method for visualizing off-surface flows is provided. The method consists of releasing a gas with infrared absorbing and emitting characteristics into a fluid flow and imaging the flow with an infrared imaging system. This method allows for visualization of off-surface fluid flow in-flight. The novelty of this method is found in providing an apparatus for flow visualization which is contained within the aircraft so as not to disrupt the airflow around the aircraft, is effective at various speeds and altitudes, and is longer-lasting than previous methods of flow visualization.
Below, Harald; Ryll, Sylvia; Empen, Klaus; Dornquast, Tina; Felix, Stefan; Rosenau, Heike; Kramer, Sebastian; Kramer, Axel
2010-01-01
In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air. Under the given conditions, disinfection of all surfaces including all furniture and equipment after the last operation and subsequent draping of furniture and all equipment that could not be removed from the room with sterile surgical drapes improved the indoor room air quality from cleanroom class C to cleanroom class B. This also allows procedures with elevated requirements to be performed in room class 1b. PMID:20941336
Fogarty, Dillon T; Elmore, R Dwayne; Fuhlendorf, Samuel D; Loss, Scott R
2017-08-01
Habitat selection by animals is influenced by and mitigates the effects of predation and environmental extremes. For birds, nest site selection is crucial to offspring production because nests are exposed to extreme weather and predation pressure. Predators that forage using olfaction often dominate nest predator communities; therefore, factors that influence olfactory detection (e.g., airflow and weather variables, including turbulence and moisture) should influence nest site selection and survival. However, few studies have assessed the importance of olfactory cover for habitat selection and survival. We assessed whether ground-nesting birds select nest sites based on visual and/or olfactory cover. Additionally, we assessed the importance of visual cover and airflow and weather variables associated with olfactory cover in influencing nest survival. In managed grasslands in Oklahoma, USA, we monitored nests of Northern Bobwhite ( Colinus virginianus ), Eastern Meadowlark ( Sturnella magna ), and Grasshopper Sparrow ( Ammodramus savannarum ) during 2015 and 2016. To assess nest site selection, we compared cover variables between nests and random points. To assess factors influencing nest survival, we used visual cover and olfactory-related measurements (i.e., airflow and weather variables) to model daily nest survival. For nest site selection, nest sites had greater overhead visual cover than random points, but no other significant differences were found. Weather variables hypothesized to influence olfactory detection, specifically precipitation and relative humidity, were the best predictors of and were positively related to daily nest survival. Selection for overhead cover likely contributed to mitigation of thermal extremes and possibly reduced detectability of nests. For daily nest survival, we hypothesize that major nest predators focused on prey other than the monitored species' nests during high moisture conditions, thus increasing nest survival on these days. Our study highlights how mechanistic approaches to studying cover informs which dimensions are perceived and selected by animals and which dimensions confer fitness-related benefits.
Influence of Applying Additional Forcing Fans for the Air Distribution in Ventilation Network
NASA Astrophysics Data System (ADS)
Szlązak, Nikodem; Obracaj, Dariusz; Korzec, Marek
2016-09-01
Mining progress in underground mines cause the ongoing movement of working areas. Consequently, it becomes necessary to adapt the ventilation network of a mine to direct airflow into newly-opened districts. For economic reasons, opening new fields is often achieved via underground workings. Length of primary intake and return routes increases and also increases the total resistance of a complex ventilation network. The development of a subsurface structure can make it necessary to change the air distribution in a ventilation network. Increasing airflow into newly-opened districts is necessary. In mines where extraction does not entail gas-related hazards, there is possibility of implementing a push-pull ventilation system in order to supplement airflows to newly developed mining fields. This is achieved by installing subsurface fan stations with forcing fans at the bottom of downcast shaft. In push-pull systems with multiple main fans, it is vital to select forcing fans with characteristic curves matching those of the existing exhaust fans to prevent undesirable mutual interaction. In complex ventilation networks it is necessary to calculate distribution of airflow (especially in networks with a large number of installed fans). In the article the influence of applying additional forcing fans for the air distribution in ventilation network for underground mine were considered. There are also analysed the extent of overpressure caused by the additional forcing fan in branches of the ventilation network (the operating range of additional forcing fan). Possibilities of increasing airflow rate in working areas were conducted.
Airflow and optic flow mediate antennal positioning in flying honeybees
Roy Khurana, Taruni; Sane, Sanjay P
2016-01-01
To maintain their speeds during navigation, insects rely on feedback from their visual and mechanosensory modalities. Although optic flow plays an essential role in speed determination, it is less reliable under conditions of low light or sparse landmarks. Under such conditions, insects rely on feedback from antennal mechanosensors but it is not clear how these inputs combine to elicit flight-related antennal behaviours. We here show that antennal movements of the honeybee, Apis mellifera, are governed by combined visual and antennal mechanosensory inputs. Frontal airflow, as experienced during forward flight, causes antennae to actively move forward as a sigmoidal function of absolute airspeed values. However, corresponding front-to-back optic flow causes antennae to move backward, as a linear function of relative optic flow, opposite the airspeed response. When combined, these inputs maintain antennal position in a state of dynamic equilibrium. DOI: http://dx.doi.org/10.7554/eLife.14449.001 PMID:27097104
Detection of flow limitation in obstructive sleep apnea with an artificial neural network.
Norman, Robert G; Rapoport, David M; Ayappa, Indu
2007-09-01
During sleep, the development of a plateau on the inspiratory airflow/time contour provides a non-invasive indicator of airway collapsibility. Humans recognize this abnormal contour easily, and this study replicates this with an artificial neural network (ANN) using a normalized shape. Five 10 min segments were selected from each of 18 sleep records (respiratory airflow measured with a nasal cannula) with varying degrees of sleep disordered breathing. Each breath was visually scored for shape, and breaths split randomly into a training and test set. Equally spaced, peak amplitude normalized flow values (representing breath shape) formed the only input to a back propagation ANN. Following training, breath-by-breath agreement of the ANN with the manual classification was tabulated for the training and test sets separately. Agreement of the ANN was 89% in the training set and 70.6% in the test set. When the categories of 'probably normal' and 'normal', and 'probably flow limited' and 'flow limited' were combined, the agreement increased to 92.7% and 89.4% respectively, similar to the intra- and inter-rater agreements obtained by a visual classification of these breaths. On a naive dataset, the agreement of the ANN to visual classification was 57.7% overall and 82.4% when the categories were collapsed. A neural network based only on the shape of inspiratory airflow succeeded in classifying breaths as to the presence/absence of flow limitation. This approach could be used to provide a standardized, reproducible and automated means of detecting elevated upper airway resistance.
Human convective boundary layer and its interaction with room ventilation flow.
Licina, D; Melikov, A; Sekhar, C; Tham, K W
2015-02-01
This study investigates the interaction between the human convective boundary layer (CBL) and uniform airflow with different velocity and from different directions. Human body is resembled by a thermal manikin with complex body shape and surface temperature distribution as the skin temperature of an average person. Particle image velocimetry (PIV) and pseudocolor visualization (PCV) are applied to identify the flow around the manikin's body. The findings show that the direction and magnitude of the surrounding airflows considerably influence the airflow distribution around the human body. Downward flow with velocity of 0.175 m/s does not influence the convective flow in the breathing zone, while flow at 0.30 m/s collides with the CBL at the nose level reducing the peak velocity from 0.185 to 0.10 m/s. Transverse horizontal flow disturbs the CBL at the breathing zone even at 0.175 m/s. A sitting manikin exposed to airflow from below with velocity of 0.30 and 0.425 m/s assisting the CBL reduces the peak velocity in the breathing zone and changes the flow pattern around the body, compared to the assisting flow of 0.175 m/s or quiescent conditions. In this case, the airflow interaction is strongly affected by the presence of the chair. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Determination of Particular Endogenous Fires Hazard Zones in Goaf with Caving of Longwall
NASA Astrophysics Data System (ADS)
Tutak, Magdalena; Brodny, Jaroslaw
2017-12-01
Hazard of endogenous fires is one of the basic and common presented occupational safety hazards in coal mine in Poland and in the world. This hazard means possibility of coal self-ignition as the result of its self-heating process in mining heading or its surrounding. In underground coal-mining during ventilating of operating longwalls takes place migration of parts of airflow to goaf with caving. In a case when in these goaf a coal susceptible to selfignition occurs, then the airflow through these goaf may influence on formation of favourable conditions for coal oxidation and subsequently to its self-heating and self-ignition. Endogenous fire formed in such conditions can pose a serious hazard for the crew and for continuity of operation of mining plant. From the practical point of view, a very significant meaning has determination of the zone in the goaf with caving, in which necessary conditions for occurrence of endogenous fire are fulfilled. In the real conditions determination of such a zone is practically impossible. Therefore, authors of paper developed a methodology of determination of this zone basing on the results of modelling tests. This methodology includes a development of model of tested area, determination of boundary conditions and carrying out the simulation calculations. Based on the obtained results particular hazardous zone of endogenous fire is determined. A base for development of model of investigated region and selection of boundary conditions are the results of real tests. In the paper fundamental assumption of developed methodology, particularly in a range of assumed hazard criterion and sealing coefficient of goaf with caving were discussed. Also a mathematical model of gas flow through the porous media was characterized. Example of determination of a zone particularly endangered by endogenous fire for real system of mining heading in one of the hard coal mine was presented. Longwall ventilated in the „Y” system was subjected to the tests. For determined mining-geological conditions, the critical value of velocity of airflow and oxygen concentration in goaf, conditioning initiation of coal oxidation process were determined. For calculations ANSYS Fluent software based on finite volume method, which enable very precisely to determine the physical and chemical air and parameters at any point of tested mining heading and goaf with caving was used. Such precisely determination of these parameters on the base of the test in real conditions is practically impossible. Obtained results allowed to take early proper actions in order to limit the occurrence of endogenous fire. One can conclude, that presented methodology creates great possibilities of practical application of modelling tests for improvement of the occupational safety state in mine.
Visualization of the air flow behind the automotive benchmark vent
NASA Astrophysics Data System (ADS)
Pech, Ondrej; Jedelsky, Jan; Caletka, Petr; Jicha, Miroslav
2015-05-01
Passenger comfort in cars depends on appropriate function of the cabin HVAC system. A great attention is therefore paid to the effective function of automotive vents and proper formation of the flow behind the ventilation outlet. The article deals with the visualization of air flow from the automotive benchmark vent. The visualization was made for two different shapes of the inlet channel connected to the benchmark vent. The smoke visualization with the laser knife was used. The influence of the shape of the inlet channel to the airflow direction, its enlargement and position of air flow axis were investigated.
NASA Astrophysics Data System (ADS)
Garcia, G. J. M.; Mitchell, G.; Bailie, N.; Thornhill, D.; Watterson, J.; Kimbell, J. S.
2007-10-01
The relationship between airflow patterns in the nasal cavity and nasal function is poorly understood. This paper reports an experimental study of the interplay between symptoms and airflow patterns in a patient affected with atrophic rhinitis. This pathology is characterized by mucosal dryness, fetor, progressive atrophy of anatomical structures, a spacious nasal cavity, and a paradoxical sensation of nasal congestion. A physical replica of the patient's nasal geometry was made and particle image velocimetry (PIV) was used to visualize and measure the flow field. The nasal replica was based on computed tomography (CT) scans of the patient and was built in three steps: three-dimensional reconstruction of the CT scans; rapid prototyping of a cast; and sacrificial use of the cast to form a model of the nasal passage in clear silicone. Flow patterns were measured by running a water-glycerol mixture through the replica and evaluating the displacement of particles dispersed in the liquid using PIV. The water-glycerol flow rate used corresponded to an air flow rate representative of a human breathing at rest. The trajectory of the flow observed in the left passage of the nose (more affected by atrophic rhinitis) differed markedly from what is considered normal, and was consistent with patterns of epithelial damage observed in cases of the condition. The data are also useful for validation of computational fluid dynamics predictions.
1985-12-19
This image shows a plastic 1/48-scale model of an F-18 aircraft inside the "Water Tunnel" more formally known as the NASA Dryden Flow Visualization Facility. Water is pumped through the tunnel in the direction of normal airflow over the aircraft; then, colored dyes are pumped through tubes with needle valves. The dyes flow back along the airframe and over the airfoils highlighting their aerodynamic characteristics. The aircraft can also be moved through its pitch axis to observe airflow disruptions while simulating actual flight at high angles of attack. The Water Tunnel at NASA's Dryden Flight Research Center, Edwards, CA, became operational in 1983 when Dryden was a Flight Research Facility under the management of the Ames Research Center in Mountain View, CA. As a medium for visualizing fluid flow, water has played a significant role. Its use dates back to Leonardo da Vinci (1452-1519), the Renaissance Italian engineer, architect, painter, and sculptor. In more recent times, water tunnels have assisted the study of complex flows and flow-field interactions on aircraft shapes that generate strong vortex flows. Flow visualization in water tunnels assists in determining the strength of vortices, their location, and possible methods of controlling them. The design of the Dryden Water Tunnel imitated that of the Northrop Corporation's tunnel in Hawthorne, CA. Called the Flow Visualization Facility, the Dryden tunnel was built to assist researchers in understanding the aerodynamics of aircraft configured in such a way that they create strong vortex flows, particularly at high angles of attack. The tunnel provides results that compare well with data from aircraft in actual flight in another fluid-air. Other uses of the tunnel have included study of how such flight hardware as antennas, probes, pylons, parachutes, and experimental fixtures affect airflow. The facility has also been helpful in finding the best locations for emitting smoke from flight vehicles for flow vi
ACHILLES, N.; PASCH, N.; LINTERMANN, A.; SCHRÖDER, W.; MÖSGES, R.
2013-01-01
SUMMARY This systematic review aims first to summarize the previous areas of application of computational fluid dynamics (CFD) and then to demonstrate that CFD is also a suitable instrument for generating three-dimensional images that depict drug effects on nasal mucosa. Special emphasis is placed on the three-dimensional visualization of the antiobstructive effect of nasal steroids and antihistamines in the treatment of allergic rhinitis. In the beginning, CFD technology was only used to demonstrate physiological and pathophysiological airflow conditions in the nose and to aid in preoperative planning and postoperative monitoring of surgical outcome in the field of rhinosurgery. The first studies using CFD examined nasal respiratory physiology, important functions of the nose, such as conditioning and warming of inspired air, and the influence of pathophysiological changes on nasal breathing. Also, postoperative outcome of surgical procedures could be "predicted" using the nasal airflow model. Later studies focused on the three-dimensional visualization of the effect of nasal sprays in healthy subjects and postoperative patients. A completely new approach, however, was the use of CFD in the area of allergic rhinitis and the treatment of its cardinal symptom of nasal obstruction. In two clinical trials, a suitable patient with a positive history of allergic rhinitis was enrolled during a symptom-free period after the pollen season. The patient developed typical allergic rhinitis symptoms after provocation with birch pollen. The 3-D visualization showed that the antiallergic treatment successfully counteracted the effects of nasal allergen provocation on nasal airflow. These observations were attributed to the antiobstructive effect of a nasal steroid (mometasone furoate) and a systemic antihistamine (levocetirizine), respectively. CFD therefore constitutes a non-invasive, precise, reliable and objective examination procedure for generating three-dimensional images that depict the effects of drugs used in the treatment of allergic rhinitis. PMID:23620638
Respiratory Source Control Using Surgical Masks With Nanofiber Media
Skaria, Shaji D.; Smaldone, Gerald C.
2014-01-01
Background: Potentially infected individuals (‘source’) are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others (‘receiver’). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Methods: Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of ‘infectious’ aerosols from the ‘source’ to a ‘receiver’). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an ‘N95 respirator’). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Results: Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, ‘infected’ source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Conclusions: Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. PMID:24737728
Respiratory source control using surgical masks with nanofiber media.
Skaria, Shaji D; Smaldone, Gerald C
2014-07-01
Potentially infected individuals ('source') are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others ('receiver'). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of 'infectious' aerosols from the 'source' to a 'receiver'). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an 'N95 respirator'). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, 'infected' source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Occupational Health and the Visual Arts: An Introduction.
Hinkamp, David; McCann, Michael; Babin, Angela R
2017-09-01
Occupational hazards in the visual arts often involve hazardous materials, though hazardous equipment and hazardous work conditions can also be found. Occupational health professionals are familiar with most of these hazards and are particularly qualified to contribute clinical and preventive expertise to these issues. Articles illustrating visual arts health issues were sought and reviewed. Literature sources included medical databases, unindexed art-health publications, and popular press articles. Few medical articles examine health issues in the visuals arts directly, but exposures to pigments, solvents, and other hazards found in the visual arts are well described. The hierarchy of controls is an appropriate model for controlling hazards and promoting safer visual art workplaces. The health and safety of those working in the visual arts can benefit from the occupational health approach. Sources of further information are available.
NASA Astrophysics Data System (ADS)
Cover, Keith S.; van Asperen, Niek; de Jong, Joost; Verdaasdonk, Rudolf M.
2013-03-01
Infection following neurosurgery is all too common. One possible source of infection is the transportation of dust and other contaminates into the open wound by airflow within the operating theatre. While many modern operating theatres have a filtered, uniform and gentle flow of air cascading down over the operating table from a large area fan in the ceiling, many obstacles might introduce turbulence into the laminar flow including lights, equipment and personal. Schlieren imaging - which is sensitive to small disturbances in the laminar flow such as breathing and turbulence caused by air warmed by a hand at body temperature - was used to image the air flow due to activities in an operating theatre. Color intensity projections (CIPs) were employed to reduce the workload of analyzing the large amount of video data. CIPs - which has been applied to images in angiography, 4D CT, nuclear medicine and astronomy - summarizes the changes over many gray scale images in a single color image in a way which most interpreters find intuitive. CIPs uses the hue, saturation and brightness of the color image to encode the summary. Imaging in an operating theatre showed substantial disruptions to the airflow due to equipment such as the lighting. When these disruptions are combined with such minor factors as heat from the hand, reversal of the preferred airflow patterns can occur. These reversals of preferred airflow patterns have the potential to transport contaminates into the open wound. Further study is required to understand both the frequency of the reversed airflow patterns and the impact they may have on infection rates.
Achilles, N; Pasch, N; Lintermann, A; Schröder, W; Mösges, R
2013-02-01
This systematic review aims first to summarize the previous areas of application of computational fluid dynamics (CFD) and then to demonstrate that CFD is also a suitable instrument for generating three-dimensional images that depict drug effects on nasal mucosa. Special emphasis is placed on the three-dimensional visualization of the antiobstructive effect of nasal steroids and antihistamines in the treatment of allergic rhinitis. In the beginning, CFD technology was only used to demonstrate physiological and pathophysiological airflow conditions in the nose and to aid in preoperative planning and postoperative monitoring of surgical outcome in the field of rhinosurgery. The first studies using CFD examined nasal respiratory physiology, important functions of the nose, such as conditioning and warming of inspired air, and the influence of pathophysiological changes on nasal breathing. Also, postoperative outcome of surgical procedures could be "predicted" using the nasal airflow model. Later studies focused on the three-dimensional visualization of the effect of nasal sprays in healthy subjects and postoperative patients. A completely new approach, however, was the use of CFD in the area of allergic rhinitis and the treatment of its cardinal symptom of nasal obstruction. In two clinical trials, a suitable patient with a positive history of allergic rhinitis was enrolled during a symptom-free period after the pollen season. The patient developed typical allergic rhinitis symptoms after provocation with birch pollen. The 3-D visualization showed that the antiallergic treatment successfully counteracted the effects of nasal allergen provocation on nasal airflow. These observations were attributed to the antiobstructive effect of a nasal steroid (mometasone furoate) and a systemic antihistamine (levocetirizine), respectively. CFD therefore constitutes a non-invasive, precise, reliable and objective examination procedure for generating three-dimensional images that depict the effects of drugs used in the treatment of allergic rhinitis.
Flow structure of natural dehumidification over a horizontal finned-tube
NASA Astrophysics Data System (ADS)
Hirbodi, Kamran; Yaghoubi, Mahmood
2016-08-01
In the present study, structure of water drops formation, growth, coalescence and departure over a horizontal finned-tube during natural dehumidification is investigated experimentally. Starting time of repelling the drops as well as heat transfer rate and the rate of dripping condensates in quasi-steady-state conditions are presented. Furthermore, cold airflow pattern around the horizontal finned-tube is visualized by using smoke generation scheme during natural dehumidification process. The finned-tube has a length of 300 mm, and inner and outer fin diameters, fin thickness and fin spacing are 25.4, 56, 0.4 and 2 mm, respectively. The tests are conducted in an insulated control room with dimensions of 5.8 m × 3 m × 4 m. Ambient air temperature, relative humidity and fin base temperature are selected from 25 to 35 °C, from 40 to 70 % and from 4 to 8 °C, respectively. Observations show that natural condensation from humid air over the test case is completely dropwise. Droplets only form on the edge of the fin and lateral fin surfaces remain almost dry. Dehumidification process over the tested finned-tube is divided into four stages; nucleation, formation, growth and departure of drops. It is also observed that the condensate inundation leaves the tube bottom in the form of droplets. Smoke visualization depicts that humid airflows downward around the cold finned-tube surface without noticeable turbulence and separation in the initial stages of dehumidification process. But the airflow has some disturbances in the intermediate stage and especially during drop departure on the edge of the fins.
2010-11-01
Human (AHAAH) which takes into account the whole signal transmission from the free sound field to the cochlear structures. Auditory Hazard Units...airflow around the aircraft canopy and the front structure of the aircraft (boundary layer flow noise), and the other is from internally generated noise...from the pressurisation and cockpit conditioning systems. The boundary layer flow noise is dependent upon the dynamic pressures on the aircraft and
Grützenmacher, S; Robinson, D M; Sevecke, J; Mlynski, G; Beule, A G
2011-03-01
Knowledge of airflow in animal noses is sparse. Such knowledge could be important for selection of animal models used in environmental studies. From the phylogenetic and ontogenetic point of view, a comparison between the animal and human nose is interesting. Nose models of 5 even-toed ungulate species (he-goat, sheep, cow, roebuck, wild boar) and two humans (new born infant and adult) were examined. Anatomical and physiological features of the nasal cavities of all species were compared. All models were rinsed with water and the flow was visualized for observation. Geometric and rhinoresistometric measurements were then performed. Even-toed ungulates have two turbinates directly in the main part of the nasal airflow (respiratory turbinates) and a different number of turbinates in a so-called dead space of the nasal airflow above the nasopharyngeal duct (ethmoidal turbinates). The latter correspond with the upper and middle turbinate in analogy to the human nose. Respiratory turbinates of even-toed ungulates insert immediately behind the external nasal ostium. Thus, the whole nasal cavity acts as a functional area with the exception of a small area acting as dead space only detectable in ruminants, possibly indicating a small evolutionary progress from suinae to bovidae. The shape of the animal nasal cavity is stretched and flat. The airflow runs nearly completely turbulent through the nose. The nasal cavity in the adult human is relatively short and high. The area between the external nasal ostium and the head of the inferior turbinate is called inflow area. It distributes the airflow over the whole nasal cross section and generates a turbulent flow. So the airflow is prepared to contact the mucosa in the functional area (turbinate area). The morphology of the inflow area is approximately formed by the shape of the external nose. The nasal cavity of a newborn child is also stretched and flat and more similar to the nasal shape of the investigated animals. The inflow area in the newborn nose is not yet developed and corresponds with the growing external newborn nose. One can hypothesize that the inflow area in human noses is a morphological adaptation in the changed length-height-ratio of the nasal cavity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carson, G.A.
1985-07-01
Environmental and breathing-zone samples were analyzed for toluene, lead, and total dust at the Saint Louis Police Auto Body Shop, Saint Louis, Missouri in January and February, 1985. The evaluation was requested by the Health Commissioner of the City of Saint Louis to investigate working conditions in the body shop. A prior health department investigation had indicated that there might be health hazards in the shop area. The author concludes that a potential health hazard exists due to overexposure to total dust while performing certain repairs at the facility. Recommendations include installing a supply air ventilation system for the exhaustmore » fans, orienting vehicles in the shop so that technicians are always working upstream of the airflow, and providing respiratory protection when it is not possible to control dust emissions.« less
Kurnia, Jundika C; Sasmito, Agus P; Wong, Wai Yap; Mujumdar, Arun S
2014-05-15
Diesel engine is widely used in underground mining machines due to its efficiency, ease of maintenance, reliability and durability. However, it possesses significant danger to the miners and mining operations as it releases hazardous gases (CO, NO, CO2) and fine particles which can be easily inhaled by the miners. Moreover, the diesel engine consumes significant amount of oxygen which can lead to insufficient oxygen supply for miners. It is therefore critical to maintain sufficient oxygen supply while keeping hazardous gas concentrations from diesel emission below the maximum allowable level. The objective of this study is to propose and to examine various innovative ventilation strategies to control oxygen and hazardous gas concentrations in underground mine to ensure safety, productivity and cost related to energy consumption. Airflow distribution, oxygen and hazardous gas dispersion as well as ambient temperature within the mining area are evaluated by utilizing the well-established computational fluid dynamics (CFD) approach. The results suggest that our newly proposed ventilation design performs better as compared to the conventional design to handle hazardous gases from diesel emission. Copyright © 2014 Elsevier B.V. All rights reserved.
Hozumi, Satoshi; Inagaki, Terumi
2010-01-01
Polybia spinifex Richards (Hymenoptera: Vespidae) constructs mud nests characterized by a long slit-like entrance. The ventilation and thermal characteristics of the P. spinifex nest were investigated to determine whether the nest microclimate is automatically maintained due to the size of the entrance. In order to examine this hypothesis, a numerical simulation was employed to predict the effects of the entrance length. The calculations were performed with 3D-virtual models that simulated the P. spinifex nest conditions, and the reliability of the simulations was experimentally examined by using gypsum-model nests and a P. spinifex nest. The ventilation effect was determined by blowing air through the nest at 1-3 m/s (airflow conditions); the airspeed was found to be higher in models with a longer entrance. The ventilation rate was also higher in models with longer entrances, suggesting that the P. spinifex nest is automatically ventilated by natural winds. Next, the thermal effect was calculated under condition of direct sunlight. Under a calm condition (airflow, 0 m/s), thermal convection and a small temperature drop were observed in the case of models with a long entrance, whereas the ventilation and thermoregulation effects seemed small. Under airflow conditions, the temperature at the mid combs steeply dropped due to the convective airflow through the entrance at 1-2 m/s, and at 3 m/s, most of the heat was eliminated due to high thermal conductivity of the mud envelope, rather than convection.
Liao, Pin-Chao; Sun, Xinlu; Liu, Mei; Shih, Yu-Nien
2018-01-11
Navigated safety inspection based on task-specific checklists can increase the hazard detection rate, theoretically with interference from scene complexity. Visual clutter, a proxy of scene complexity, can theoretically impair visual search performance, but its impact on the effect of safety inspection performance remains to be explored for the optimization of navigated inspection. This research aims to explore whether the relationship between working memory and hazard detection rate is moderated by visual clutter. Based on a perceptive model of hazard detection, we: (a) developed a mathematical influence model for construction hazard detection; (b) designed an experiment to observe the performance of hazard detection rate with adjusted working memory under different levels of visual clutter, while using an eye-tracking device to observe participants' visual search processes; (c) utilized logistic regression to analyze the developed model under various visual clutter. The effect of a strengthened working memory on the detection rate through increased search efficiency is more apparent in high visual clutter. This study confirms the role of visual clutter in construction-navigated inspections, thus serving as a foundation for the optimization of inspection planning.
Effects of surface dielectric barrier discharge on aerodynamic characteristic of train
NASA Astrophysics Data System (ADS)
Dong, Lei; Gao, Guoqiang; Peng, Kaisheng; Wei, Wenfu; Li, Chunmao; Wu, Guangning
2017-07-01
High-speed railway today has become an indispensable means of transportation due to its remarkable advantages, including comfortability, convenience and less pollution. The increase in velocity makes the air drag become the main source of energy consumption, leading to receiving more and more concerns. The surface dielectric barrier discharge has shown some unique characteristics in terms of active airflow control. In this paper, the influences of surface dielectric barrier discharge on the aerodynamic characteristics of a scaled train model have been studied. Aspects of the discharge power consumption, the temperature distribution, the velocity of induced flow and the airflow field around the train model were considered. The applied AC voltage was set in the range of 20 kV to 28 kV, with a fixed frequency of 9 kHz. Results indicated that the discharge power consumption, the maximum temperature and the induced flow velocity increased with increasing applied voltage. Mechanisms of applied voltage influencing these key parameters were discussed from the point of the equivalent circuit. The airflow field around the train model with different applied voltages was observed by the smoke visualization experiment. Finally, the effects of surface dielectric barrier discharge on the train drag reduction with different applied voltages were analyzed.
Reviewing and visualizing the interactions of natural hazards
NASA Astrophysics Data System (ADS)
Gill, Joel C.; Malamud, Bruce D.
2014-12-01
This paper presents a broad overview, characterization, and visualization of the interaction relationships between 21 natural hazards, drawn from six hazard groups (geophysical, hydrological, shallow Earth, atmospheric, biophysical, and space hazards). A synthesis is presented of the identified interaction relationships between these hazards, using an accessible visual format particularly suited to end users. Interactions considered are primarily those where a primary hazard triggers or increases the probability of secondary hazards occurring. In this paper we do the following: (i) identify, through a wide-ranging review of grey- and peer-review literature, 90 interactions; (ii) subdivide the interactions into three levels, based on how well we can characterize secondary hazards, given information about the primary hazard; (iii) determine the spatial overlap and temporal likelihood of the triggering relationships occurring; and (iv) examine the relationship between primary and secondary hazard intensities for each identified hazard interaction and group these into five possible categories. In this study we have synthesized, using accessible visualization techniques, large amounts of information drawn from many scientific disciplines. We outline the importance of constraining hazard interactions and reinforce the importance of a holistic (or multihazard) approach to natural hazard assessment. This approach allows those undertaking research into single hazards to place their work within the context of other hazards. It also communicates important aspects of hazard interactions, facilitating an effective analysis by those working on reducing and managing disaster risk within both the policy and practitioner communities.
Change in airflow among patients with asthma discussing relationship problems with their partners.
Schmaling, Karen B; Afari, Niloofar; Hops, Hyman; Barnhart, Scott; Buchwald, Dedra
2009-09-01
This study examined the covariation of negative emotions with airflow among 48 persons with asthma and their partners as they discussed relationship problems. Measures included self-reported questionnaires, airflow and behavior coded from videotaped discussions. Significantly increased self-reported hostility and statistically but not clinically significant declines in airflow were found post- versus pre-discussion. Self-reported responses to asthma symptoms of more anger and less loneliness predicted lower post-discussion airflow after accounting for pre-discussion airflow. The use of effort-independent measures of airflow and autonomic nervous system monitoring may inform future research regarding the physiological mechanisms through which mood and behavior affect airflow.
Oelsner, Elizabeth C.; Hoffman, Eric A.; Folsom, Aaron R.; Carr, J. Jeffrey; Enright, Paul L.; Kawut, Steven M.; Kronmal, Richard; Lederer, David; Lima, Joao A. C.; Lovasi, Gina S.; Shea, Steven; Barr, R. Graham
2015-01-01
Background Whereas low lung function is known to predict mortality in the general population, the prognostic significance of emphysema on computed tomography (CT) in persons without chronic obstructive pulmonary disease (COPD) remains uncertain. Objective To determine whether greater emphysema-like lung on CT is associated with all-cause mortality among persons without airflow obstruction or COPD in the general population. Design Prospective cohort study. Setting Population-based, multiethnic sample from 6 US communities. Participants 2965 participants ages 45-84 years without airflow obstruction on spirometry. Measurements Emphysema-like lung was defined on cardiac CT as the number of lung voxels less than -950 Hounsfield Units, and was adjusted for the number of total imaged lung voxels. Results Among 2965 participants, 50.9% of whom never smoked, there were 186 deaths over a median of 6.2 years. Greater emphysema-like lung was independently associated with increased mortality (adjusted hazard ratio [HR]1.14 per one-half of the interquartile range, 95% CI 1.04-1.24, P=0.004), adjusting for potential confounders including cardiovascular risk factors and the forced expiratory volume in one second. Generalized additive models supported a linear association between emphysema-like lung and mortality without evidence for a threshold. The association was of greatest magnitude among smokers, although multiplicative interaction terms did not support effect modification by smoking status. Limitations Cardiac CT scans did not include lung apices. The number of deaths was limited among subgroup analyses. Conclusions Emphysema-like lung on CT was associated with all-cause mortality among persons without airflow obstruction or COPD in a general population sample, particularly among smokers. Recognition of the independent prognostic significance of emphysema on CT among patients without COPD on spirometry is warranted. Primary Funding Source NIH/NHLBI. PMID:25506855
Zeig-Owens, Rachel; Singh, Ankura; Aldrich, Thomas K; Hall, Charles B; Schwartz, Theresa; Webber, Mayris P; Cohen, Hillel W; Kelly, Kerry J; Nolan, Anna; Prezant, David J; Weiden, Michael D
2018-02-01
Rescue/recovery work at the World Trade Center disaster site (WTC) caused a proximate decline in lung function in Fire Department of the City of New York firefighters. A subset of this cohort experienced an accelerated rate of lung function decline over 15 years of post-September 11, 2001 (9/11) follow-up. To determine if early postexposure blood leukocyte concentrations are biomarkers for subsequent FEV 1 decline and incident airflow limitation. Individual rates of forced expiratory volume in 1 second (FEV 1 ) change were calculated for 9,434 firefighters using 88,709 spirometric measurements taken between September 11, 2001, and September 10, 2016. We categorized FEV 1 change rates into three trajectories: accelerated FEV 1 decline (FEV 1 loss >64 ml/yr), expected FEV 1 decline (FEV 1 loss between 0 and 64 ml/yr), and improved FEV 1 (positive rate of change >0 ml/yr). Occurrence of FEV 1 /FVC less than 0.70 after 9/11 defined incident airflow limitation. Using regression models, we assessed associations of post-9/11 blood eosinophil and neutrophil concentrations with subsequent FEV 1 decline and airflow limitation, adjusted for age, race, smoking, height, WTC exposure level, weight change, and baseline lung function. Accelerated FEV 1 decline occurred in 12.7% of participants (1,199 of 9,434), whereas post-9/11 FEV 1 improvement occurred in 8.3% (780 of 9,434). Higher blood eosinophil and neutrophil concentrations were each associated with accelerated FEV 1 decline after adjustment for covariates (odds ratio [OR], 1.10 per 100 eosinophils/μl; 95% confidence interval [CI], 1.05-1.15; and OR, 1.10 per 1,000 neutrophils/μl; 95% CI, 1.05-1.15, respectively). Multivariable-adjusted linear regression models showed that a higher blood neutrophil concentration was associated with a faster rate of FEV 1 decline (1.14 ml/yr decline per 1,000 neutrophils/μl; 95% CI, 0.69-1.60 ml/yr; P < 0.001). Higher blood eosinophil concentrations were associated with a faster rate of FEV 1 decline in ever-smokers (1.46 ml/yr decline per 100 eosinophils/μl; 95% CI, 0.65-2.26 ml/yr; P < 0.001) but not in never-smokers (P for interaction = 0.004). Higher eosinophil concentrations were also associated with incident airflow limitation (adjusted hazard ratio, 1.10 per 100 eosinophils/μl; 95% CI, 1.04-1.15). Compared with the expected FEV 1 decline group, individuals experiencing accelerated FEV 1 decline were more likely to have incident airflow limitation (adjusted OR, 4.12; 95% CI, 3.30-5.14). Higher post-9/11 blood neutrophil and eosinophil concentrations were associated with subsequent accelerated FEV 1 decline in WTC-exposed firefighters. Both higher blood eosinophil concentrations and accelerated FEV 1 decline were associated with incident airflow limitation in WTC-exposed firefighters.
Tang, Julian W.; Liebner, Thomas J.; Craven, Brent A.; Settles, Gary S.
2009-01-01
Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask). PMID:19815575
Tang, Julian W; Liebner, Thomas J; Craven, Brent A; Settles, Gary S
2009-12-06
Various infectious agents are known to be transmitted naturally via respiratory aerosols produced by infected patients. Such aerosols may be produced during normal activities by breathing, talking, coughing and sneezing. The schlieren optical method, previously applied mostly in engineering and physics, can be effectively used here to visualize airflows around human subjects in such indoor situations, non-intrusively and without the need for either tracer gas or airborne particles. It accomplishes this by rendering visible the optical phase gradients owing to real-time changes in air temperature. In this study, schlieren video records are obtained of human volunteers coughing with and without wearing standard surgical and N95 masks. The object is to characterize the exhaled airflows and evaluate the effect of these commonly used masks on the fluid-dynamic mechanisms that spread infection by coughing. Further, a high-speed schlieren video of a single cough is analysed by a computerized method of tracking individual turbulent eddies, demonstrating the non-intrusive velocimetry of the expelled airflow. Results show that human coughing projects a rapid turbulent jet into the surrounding air, but that wearing a surgical or N95 mask thwarts this natural mechanism of transmitting airborne infection, either by blocking the formation of the jet (N95 mask), or by redirecting it in a less harmful direction (surgical mask).
'I didn't see that coming': simulated visual fields and driving hazard perception test performance.
Glen, Fiona C; Smith, Nicholas D; Jones, Lee; Crabb, David P
2016-09-01
Evidence is limited regarding specific types of visual field loss associated with unsafe driving. We use novel gaze-contingent software to examine the effect of simulated visual field loss on computer-based driving hazard detection with the specific aim of testing the impact of scotomata located to the right and left of fixation. The 'hazard perception test' is a component of the UK driving licence examination, which measures speed of detecting 15 different hazards in a series of real-life driving films. We have developed a novel eye-tracking and computer set up capable of generating a realistic gaze-contingent scotoma simulation (GazeSS) overlaid on film content. Thirty drivers with healthy vision completed three versions of the hazard perception test in a repeated measures experiment. In two versions, GazeSS simulated a scotoma in the binocular field of view to the left or right of fixation. A third version was unmodified to establish baseline performance. Participants' mean baseline hazard perception test score was 51 ± 7 (out of 75). This reduced to 46 ± 9 and 46 ± 11 when completing the task with a binocular visual field defect located to the left and right of fixation, respectively. While the main effect of simulated visual field loss on performance was statistically significant (p = 0.007), there were no average differences in the experimental conditions where a scotoma was located in the binocular visual field to the right or left of fixation. Simulated visual field loss impairs driving hazard detection on a computer-based test. There was no statistically significant difference in average performance when the simulated scotoma was located to the right or left of fixation of the binocular visual field, but certain types of hazard caused more difficulties than others. © 2016 Optometry Australia.
Flow visualization study of grooved surface/surfactant/air sheet interaction
NASA Technical Reports Server (NTRS)
Reed, Jason C.; Weinstein, Leonard M.
1989-01-01
The effects of groove geometry, surfactants, and airflow rate have been ascertained by a flow-visualization study of grooved-surface models which addresses the possible conditions for skin friction-reduction in marine vehicles. It is found that the grooved surface geometry holds the injected bubble stream near the wall and, in some cases, results in a 'tube' of air which remains attached to the wall. It is noted that groove dimension and the use of surfactants can substantially affect the stability of this air tube; deeper grooves, surfactants with high contact angles, and angled air injection, are all found to increase the stability of the attached air tube, while convected disturbances and high shear increase interfacial instability.
Lung Function Abnormalities in Smokers with Ischemic Heart Disease.
Franssen, Frits M E; Soriano, Joan B; Roche, Nicolas; Bloomfield, Paul H; Brusselle, Guy; Fabbri, Leonardo M; García-Rio, Francisco; Kearney, Mark T; Kwon, Namhee; Lundbäck, Bo; Rabe, Klaus F; Raillard, Alice; Muellerova, Hana; Cockcroft, John R
2016-09-01
The aim of the ALICE (Airflow Limitation in Cardiac Diseases in Europe) study was to investigate the prevalence of airflow limitation in patients with ischemic heart disease and the effects on quality of life, healthcare use, and future health risk. To examine prebronchodilator and post-bronchodilator spirometry in outpatients aged greater than or equal to 40 years with clinically documented ischemic heart disease who were current or former smokers. This multicenter, cross-sectional study was conducted in 15 cardiovascular outpatient clinics in nine European countries. Airflow limitation was defined as post-bronchodilator FEV1/FVC less than 0.70. Among the 3,103 patients with ischemic heart disease who were recruited, lung function was defined for 2,730 patients. Airflow limitation was observed in 30.5% of patients with ischemic heart disease: 11.3% had mild airflow limitation, 15.8% moderate airflow limitation, 3.3% severe airflow limitation, and 0.1% very severe airflow limitation. Most patients with airflow limitation (70.6%) had no previous spirometry testing or diagnosed pulmonary disease. Airflow limitation was associated with greater respiratory symptomatology, impaired health status, and more frequent emergency room visits (P < 0.05). Airflow limitation compatible with chronic obstructive pulmonary disease affects almost one-third of patients with ischemic heart disease. Although airflow limitation is associated with additional morbidity and societal burden, it is largely undiagnosed and untreated. Clinical trial registered with www.clinicaltrials.gov (NCT 01485159).
NASA Astrophysics Data System (ADS)
Fan, Zhihui; Yan, Huijie; Liu, Yidi; Guo, Hongfei; Wang, Yuying; Ren, Chunsheng
2018-05-01
Atmospheric-pressure dielectric barrier discharge (DBD) with airflow participation has been widely used in recent years. In this paper, effects of airflow on DBD characteristics are experimentally investigated by single/double pin-to-plate DBD arrangements with an AC exciting source. The discharge electrical characteristics and the movements of discharge channels in airflow are investigated with a single pin electrode arrangement. The current intensities increase in positive cycles and decrease in negative cycles with the increase in airflow velocity. The transition from a filamentary discharge to a diffuse discharge is observed under certain airflow conditions, and the discharge channels move with the airflow with a movement velocity less than the corresponding airflow velocity. In the cases of double pin electrode arrangements, the repulsion between double pin discharge channels is apparent at a 10 mm distance but is not obvious at a 20 mm distance. When the airflow is introduced into the discharge gap, not as in the case of single pin electrode arrangement, the movements of discharge channels in airflow are affected by adjacent discharge channels. The corresponding reasons are analyzed in the paper.
Advanced Video Data-Acquisition System For Flight Research
NASA Technical Reports Server (NTRS)
Miller, Geoffrey; Richwine, David M.; Hass, Neal E.
1996-01-01
Advanced video data-acquisition system (AVDAS) developed to satisfy variety of requirements for in-flight video documentation. Requirements range from providing images for visualization of airflows around fighter airplanes at high angles of attack to obtaining safety-of-flight documentation. F/A-18 AVDAS takes advantage of very capable systems like NITE Hawk forward-looking infrared (FLIR) pod and recent video developments like miniature charge-couple-device (CCD) color video cameras and other flight-qualified video hardware.
Construction schedule simulation of a diversion tunnel based on the optimized ventilation time.
Wang, Xiaoling; Liu, Xuepeng; Sun, Yuefeng; An, Juan; Zhang, Jing; Chen, Hongchao
2009-06-15
Former studies, the methods for estimating the ventilation time are all empirical in construction schedule simulation. However, in many real cases of construction schedule, the many factors have impact on the ventilation time. Therefore, in this paper the 3D unsteady quasi-single phase models are proposed to optimize the ventilation time with different tunneling lengths. The effect of buoyancy is considered in the momentum equation of the CO transport model, while the effects of inter-phase drag, lift force, and virtual mass force are taken into account in the momentum source of the dust transport model. The prediction by the present model for airflow in a diversion tunnel is confirmed by the experimental values reported by Nakayama [Nakayama, In-situ measurement and simulation by CFD of methane gas distribution at a heading faces, Shigen-to-Sozai 114 (11) (1998) 769-775]. The construction ventilation of the diversion tunnel of XinTangfang power station in China is used as a case. The distributions of airflow, CO and dust in the diversion tunnel are analyzed. A theory method for GIS-based dynamic visual simulation for the construction processes of underground structure groups is presented that combines cyclic operation network simulation, system simulation, network plan optimization, and GIS-based construction processes' 3D visualization. Based on the ventilation time the construction schedule of the diversion tunnel is simulated by the above theory method.
NASA Astrophysics Data System (ADS)
Halboth, Florian; Roces, Flavio
2017-10-01
Air exchange between the large nests of Atta vollenweideri leaf-cutting ants and the environment strongly relies on a passive, wind-induced ventilation mechanism. Air moves through nest tunnels and airflow direction depends on the location of the tunnel openings on the nest mound. We hypothesized that ants might use the direction of airflow along nest tunnels as orientation cue in the context of climate control, as digging workers might prefer to broaden or to close tunnels with inflowing or outflowing air in order to regulate nest ventilation. To investigate anemotactic orientation in Atta vollenweideri, we first tested the ants' ability to perceive air movements by confronting single workers with airflow stimuli in the range 0 to 20 cm/s. Workers responded to airflow velocities ≥ 2 cm/s, and the number of ants reacting to the stimulus increased with increasing airflow speed. Second, we asked whether digging workers use airflow direction as an orientation cue. Workers were exposed to either inflow or outflow of air while digging in the nest and could subsequently choose between two digging sites providing either inflow or outflow of air, respectively. Workers significantly chose the side with the same airflow direction they experienced before. When no airflow was present during initial digging, workers showed no preference for airflow directions. Workers developed preferences for airflow direction only after previous exposure to a given airflow direction. We suggest that experience-modified anemotaxis might help leaf-cutting ants spatially organize their digging activity inside the nest during tasks related to climate control.
Halboth, Florian; Roces, Flavio
2017-09-19
Air exchange between the large nests of Atta vollenweideri leaf-cutting ants and the environment strongly relies on a passive, wind-induced ventilation mechanism. Air moves through nest tunnels and airflow direction depends on the location of the tunnel openings on the nest mound. We hypothesized that ants might use the direction of airflow along nest tunnels as orientation cue in the context of climate control, as digging workers might prefer to broaden or to close tunnels with inflowing or outflowing air in order to regulate nest ventilation. To investigate anemotactic orientation in Atta vollenweideri, we first tested the ants' ability to perceive air movements by confronting single workers with airflow stimuli in the range 0 to 20 cm/s. Workers responded to airflow velocities ≥ 2 cm/s, and the number of ants reacting to the stimulus increased with increasing airflow speed. Second, we asked whether digging workers use airflow direction as an orientation cue. Workers were exposed to either inflow or outflow of air while digging in the nest and could subsequently choose between two digging sites providing either inflow or outflow of air, respectively. Workers significantly chose the side with the same airflow direction they experienced before. When no airflow was present during initial digging, workers showed no preference for airflow directions. Workers developed preferences for airflow direction only after previous exposure to a given airflow direction. We suggest that experience-modified anemotaxis might help leaf-cutting ants spatially organize their digging activity inside the nest during tasks related to climate control.
NASA Astrophysics Data System (ADS)
Mikeš, J.; Pekárek, S.; Soukup, I.
2016-11-01
This study examines the effect of airflow orientation with respect to the strip active electrode on concentration of ozone and nitrogen dioxide produced in a planar generator based on the surface dielectric barrier discharge. The orientation of the airflow was tested in parallel and perpendicular with respect to the strips. It was found that in the investigated range of average discharge power, the ozone concentration increases approximately by 25% when airflow was oriented in parallel with respect to the strips in comparison with perpendicular orientation of the airflow. Similarly the increase of nitrogen dioxide concentration was observed for parallel orientation of the airflow with respect to the strips in comparison with the perpendicular orientation of the airflow. Within the range of wavelengths from 250 to 1100 nm, the changes of intensities of spectral lines associated with airflow orientation have been observed. A 3D numerical model describing ion trajectories and airflow patterns have also been developed.
Power requirement of rotating rods in airflow
NASA Technical Reports Server (NTRS)
Barna, P. S.; Crossman, G. R.
1974-01-01
Experiments were performed to determine the power required for rotating a rotor disc fitted with a number of radially arranged rods placed into a ducted airflow. An array of stationary rods, also radially arranged, were placed upstream close to the rotor with a small gap between the rods to cause wake interference. The results show that power increased with increasing airflow and the rate of increase varied considerably. At lower values of airflow the rate of increase was larger than at higher airflow and definite power peaks occurred at certain airflow rates, where the power attained a maximum within the test airflow range. During the test a maximum blade passage frequency of 2037 Hz was attained.
Airflow obstruction, atherosclerosis and cardiovascular risk factors in the AGES Reykjavik study.
Gudmundsson, Gunnar; Margretardottir, Olof Birna; Sigurdsson, Martin Ingi; Harris, Tamara B; Launer, Lenore J; Sigurdsson, Sigurdur; Olafsson, Orn; Aspelund, Thor; Gudnason, Vilmundur
2016-09-01
Airflow limitation, i.e. reduced forced expiratory volume in 1-s (FEV1), is associated with increased prevalence of atherosclerosis, however, causal mechanisms remain elusive. The objective of the study was to determine if the association between airflow obstruction and markers of atherosclerosis is mediated by systemic inflammation. 1154 subjects from the longitudinal AGES Reykjavik study were included. Population characteristics, systemic inflammation markers from blood (white blood cell counts (WBC) and level of C-reactive protein (CRP)) were compared between patients with and without airflow limitation defined by reduced FEV1 on spirometry. Atherosclerosis burden was quantified by measurements of coronary artery calcium, aortic arch and distal aortic calcification in addition to carotid intimal media thickness (CIMT). Subjects were split into four groups according to smoking status and whether airflow limitation was present. There was a higher overall burden of atherosclerosis in ever-smokers compared to never-smokers, and in individuals with airflow obstruction compared to individuals without airflow obstruction. After adjusting for population characteristics, Framingham cardiovascular risk factors and markers of systemic inflammation (WBC and CRP), there was a significantly increased aortic arch and distal aorta calcification and higher CIMT measurement in individuals with airflow obstruction compared to individuals without airflow obstruction. After adjusting for population characteristics, Framingham cardiovascular risk factors and markers of systemic inflammation (WBC and CRP), there was a significantly increased aortic arch and distal aorta calcification and higher CIMT measurement in individuals with airflow obstruction compared to individuals without airflow obstruction. Systemic inflammation (WBC and CRP) does not appear to mediate the association between airflow limitation and atherosclerosis. Only airflow limitation and not systemic inflammation (WBC and CRP) appears to be an independent predictor of atherosclerosis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Investigation of non-uniform airflow signal oscillation during high frequency chest compression
Sohn, Kiwon; Warwick, Warren J; Lee, Yong W; Lee, Jongwon; Holte, James E
2005-01-01
Background High frequency chest compression (HFCC) is a useful and popular therapy for clearing bronchial airways of excessive or thicker mucus. Our observation of respiratory airflow of a subject during use of HFCC showed the airflow oscillation by HFCC was strongly influenced by the nonlinearity of the respiratory system. We used a computational model-based approach to analyse the respiratory airflow during use of HFCC. Methods The computational model, which is based on previous physiological studies and represented by an electrical circuit analogue, was used for simulation of in vivo protocol that shows the nonlinearity of the respiratory system. Besides, airflow was measured during use of HFCC. We compared the simulation results to either the measured data or the previous research, to understand and explain the observations. Results and discussion We could observe two important phenomena during respiration pertaining to the airflow signal oscillation generated by HFCC. The amplitudes of HFCC airflow signals varied depending on spontaneous airflow signals. We used the simulation results to investigate how the nonlinearity of airway resistance, lung capacitance, and inertance of air characterized the respiratory airflow. The simulation results indicated that lung capacitance or the inertance of air is also not a factor in the non-uniformity of HFCC airflow signals. Although not perfect, our circuit analogue model allows us to effectively simulate the nonlinear characteristics of the respiratory system. Conclusion We found that the amplitudes of HFCC airflow signals behave as a function of spontaneous airflow signals. This is due to the nonlinearity of the respiratory system, particularly variations in airway resistance. PMID:15904523
Ogawa, M
2000-01-01
A unidirectional airflow workstation for processing a sterile pharmaceutical product is required to be "Grade A," according to EU-GMP and WHO-GMP. These regulations have employed the wording of "laminar airflow" for unidirectional airflow, with an unclear definition given. This seems to have allowed many reports to describe discussion of airflow velocity only. The guidance values as to the velocity are expressed in various words of 90 ft/min, 0.45 m/sec, 0.3 m/sec, +/- 20%, or "homogeneous air speed." It has been also little clarified how variation in airflow velocity gives influences on contamination control of a workstation working with varying key characteristics, such as ceiling height, internal heat load, internal particle generation, etc. The present author has revealed following points from a case study using Computational Fluid Dynamics: the airflow characteristic in Grade A area shows no significant changes with varying the velocity of supplied airflow, and the particles generated from the operator will be exhausted outside Grade A area without contamination.
Mechanical responses of rat vibrissae to airflow
Yu, Yan S. W.; Graff, Matthew M.; Hartmann, Mitra J. Z.
2016-01-01
ABSTRACT The survival of many animals depends in part on their ability to sense the flow of the surrounding fluid medium. To date, however, little is known about how terrestrial mammals sense airflow direction or speed. The present work analyzes the mechanical response of isolated rat macrovibrissae (whiskers) to airflow to assess their viability as flow sensors. Results show that the whisker bends primarily in the direction of airflow and vibrates around a new average position at frequencies related to its resonant modes. The bending direction is not affected by airflow speed or by geometric properties of the whisker. In contrast, the bending magnitude increases strongly with airflow speed and with the ratio of the whisker's arc length to base diameter. To a much smaller degree, the bending magnitude also varies with the orientation of the whisker's intrinsic curvature relative to the direction of airflow. These results are used to predict the mechanical responses of vibrissae to airflow across the entire array, and to show that the rat could actively adjust the airflow data that the vibrissae acquire by changing the orientation of its whiskers. We suggest that, like the whiskers of pinnipeds, the macrovibrissae of terrestrial mammals are multimodal sensors – able to sense both airflow and touch – and that they may play a particularly important role in anemotaxis. PMID:27030774
Roopa Manjunatha, G; Mahapatra, D Roy; Prakash, Surya; Rajanna, K
2015-01-01
The aim of this study is to validate the applicability of the PolyVinyliDene Fluoride (PVDF) nasal sensor to assess the nasal airflow, in healthy subjects and patients with nasal obstruction and to correlate the results with the score of Visual Analogue Scale (VAS). PVDF nasal sensor and VAS measurements were carried out in 50 subjects (25-healthy subjects and 25 patients). The VAS score of nasal obstruction and peak-to-peak amplitude (Vp-p) of nasal cycle measured by PVDF nasal sensors were analyzed for right nostril (RN) and left nostril (LN) in both the groups. Spearman's rho correlation was calculated. The relationship between PVDF nasal sensor measurements and severity of nasal obstruction (VAS score) were assessed by ANOVA. In healthy group, the measurement of nasal airflow by PVDF nasal sensor for RN and LN were found to be 51.14±5.87% and 48.85±5.87%, respectively. In patient group, PVDF nasal sensor indicated lesser nasal airflow in the blocked nostrils (RN: 23.33±10.54% and LN: 32.24±11.54%). Moderate correlation was observed in healthy group (r=-0.710, p<0.001 for RN and r=-0.651, p<0.001 for LN), and moderate to strong correlation in patient group (r=-0.751, p<0.01 for RN and r=-0.885, p<0.0001 for LN). PVDF nasal sensor method is a newly developed technique for measuring the nasal airflow. Moderate to strong correlation was observed between PVDF nasal sensor data and VAS scores for nasal obstruction. In our present study, PVDF nasal sensor technique successfully differentiated between healthy subjects and patients with nasal obstruction. Additionally, it can also assess severity of nasal obstruction in comparison with VAS. Thus, we propose that the PVDF nasal sensor technique could be used as a new diagnostic method to evaluate nasal obstruction in routine clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.
Restorative procedures in disturbed function of the upper airways - nasal breathing
Mlynski, Gunter
2005-01-01
These days, functional rhinosurgery is almost always taken to mean the improvement of nasal airflow. However, air should not only pass through the nose without obstruction. It needs to be warmed, moistened and filtered. This requires sufficient air/mucous membrane contact by spreading airflow over the entire turbinate region, as well as regulation of nasal airway resistance and the degree of turbulence within the nasal cycle. These factors are not considered enough in the concept of functional rhinosurgery. There cannot be a rigid concept for functional/aesthetic rhinosurgery, the surgical procedure must be adapted to the individual anatomy and pathology. In spite of this, it must be clear (based on evidence) which surgical steps can solve a functional problem of the nose in the long term. This paper cannot explain evidence-based treatment strategies to restore nasal respiratory function because in all branches of rhinosurgery, there are no prospective studies available with a sufficiently high sample size and long-term results objectivized by functional diagnosis. Studies available on septal surgery show better results for SP after Cottle than for SMR after Killian. However, the success rate of a 70 to 80% improvement in nasal breathing is not satisfactory. The incidence of postoperative, dry nasal mucosa is also too high. The task of rhinology is to stress the functional side of rhinosurgery more. This includes preoperative analysis of the causes of disturbed respiratory function using the functional diagnosis methods available, the use of evidence-based surgical techniques and postoperative, objectivized quality control. More research needs to be done on the physiology and pathophysiology of nasal airflow as well as on the effect of rhinosurgery on airflow. Numerical flow simulation can contribute greatly to this because the effects of shape changes on the flow can be visualized. Methods need to be developed which can be used for routine, diagnostic recording of warming, moistening and filtering of the respiratory air. PMID:22073055
Voluntary upregulation of reflex cough is possible in healthy older adults and Parkinson's disease.
Brandimore, Alexandra E; Hegland, Karen W; Okun, Michael S; Davenport, Paul W; Troche, Michelle S
2017-07-01
Cough is an airway-protective mechanism that serves to detect and forcefully eject aspirate material. Existing research has identified the ability of healthy young adults to suppress or modify cough motor output based on external cueing. However, no study has evaluated the ability of people with Parkinson's disease (PD) and healthy older adults (HOAs) to upregulate cough motor output. The goal of this study was to evaluate the ability of people with PD and healthy age-matched controls (HOAs) to upregulate reflex and voluntary cough function volitionally with verbal instruction and visual biofeedback of airflow targets. Sixteen participants with PD and twenty-eight HOAs (56-83 yr old) were recruited for this study. Experimental procedures used spirometry to evaluate 1 ) baseline reflex cough (evoked with capsaicin) and voluntary sequential cough and 2 ) reflex and voluntary cough with upregulation biofeedback. Cough airflow was recorded and repeated-measures ANOVA was used to analyze differences in cough airflow parameters. Cough peak expiratory airflow rate and cough expired volume were significantly greater in the cueing condition for both induced reflex ( P < 0.001) and voluntary cough ( P < 0.001) compared with baseline measures. This is the first study to demonstrate the ability of people with PD and HOAs to upregulate induced reflex and voluntary cough motor output volitionally. These results support the development of studies targeting improved cough effectiveness in patients with airway-protective deficits. NEW & NOTEWORTHY Aspiration pneumonia is a leading cause of death in Parkinson's disease (PD) and results from concurrent dysphagia and dystussia (cough dysfunction). This is the first study to demonstrate that people with PD and healthy age-matched controls can volitionally upregulate induced reflex and voluntary cough effectiveness when presented with novel cueing strategies. Thus targeting upregulation of cough effectiveness via biofeedback may be a viable way to enhance airway protection in people with PD. Copyright © 2017 the American Physiological Society.
Leclerc, Lara; Merhie, Amira El; Navarro, Laurent; Prévôt, Nathalie; Durand, Marc; Pourchez, Jérémie
2015-10-15
We investigated the impact of vibrating acoustic airflow, the high frequency (f≥100 Hz) and the low frequency (f≤45 Hz) sound waves, on the enhancement of intrasinus drug deposition. (81m)Kr-gas ventilation study was performed in a plastinated human cast with and without the addition of vibrating acoustic airflow. Similarly, intrasinus drug deposition in a nasal replica using gentamicin as a marker was studied with and without the superposition of different modes of acoustic airflow. Ventilation experiments demonstrate that no sinus ventilation was observed without acoustic airflow although sinus ventilation occurred whatever the modes of acoustic airflow applied. Intrasinus drug deposition experiments showed that the high frequency acoustic airflow led to 4-fold increase in gentamicin deposition into the left maxillary sinus and to 2-fold deposition increase into the right maxillary sinus. Besides, the low frequency acoustic airflow demonstrated a significant increase of 4-fold and 2-fold in the right and left maxillary sinuses, respectively. We demonstrated the benefit of different modes of vibrating acoustic airflow for maxillary sinus ventilation and intrasinus drug deposition. The degree of gentamicin deposition varies as a function of frequency of the vibrating acoustic airflow and the geometry of the ostia. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Sanders, B. W.
1980-01-01
The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with large, porous bleed areas to provide a stability bypass system that would allow a large, stable airflow range. Exhaust-nozzle, secondary-airflow pumping was used as the exit control for the stability bypass airflow. Propulsion system response and stability bypass performance were obtained for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area, as well as compressor stall. Nozzle secondary pumping as a stability bypass exit control can provide the inlet with a large stability margin with no adverse effects on propulsion system performance.
The Measurement of Airflow Using Singing Helmet That Allows Free Movement of the Jaw.
Jiang, Jack J; Hanna, Rewais B; Willey, Malachi V; Rieves, Adam
2016-11-01
Airflow measurement is a useful method of evaluating laryngeal physiology. We introduce a noninvasive device that measures airflow without restricting jaw movement or requiring phonation into a mouthpiece, thus facilitating measurement during singing and connected speech. Validation and human subject trials were conducted. Airflow measurements were obtained from 16 male and 16 female subjects during singing, speech, and constant vowel production tasks. A similar helmet was designed by Stevens and Mead in 1968. The new device validity was evaluated by comparing the measured volume of air to a known volume of administered air using a calibration syringe. Subjects were asked to voice sustained vowels at low, medium, and high vocal intensity, read two sentences at a conversational volume, and perform different singing exercises while airflow was recorded. The device accurately and reliably measured airflow with mean airflow values falling within previously published ranges. There was an experimentally determined response time of 0.173 ± 0.014 seconds. Subjects were able to comfortably perform speech and singing exercises. Male subjects had higher airflow for all sustained vowels (P < 0.05). Airflow was higher for abduction rather than adduction sentences (P < 0.05). No other portable device has been shown to measure airflow during singing and speech while allowing for free movement of the jaw. This device provides a more natural environment to measure airflow that could be used to help evaluate laryngeal function and aid in singing training. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Empiric determination of corrected visual acuity standards for train crews.
Schwartz, Steven H; Swanson, William H
2005-08-01
Probably the most common visual standard for employment in the transportation industry is best-corrected, high-contrast visual acuity. Because such standards were often established absent empiric linkage to job performance, it is possible that a job applicant or employee who has visual acuity less than the standard may be able to satisfactorily perform the required job activities. For the transportation system that we examined, the train crew is required to inspect visually the length of the train before and during the time it leaves the station. The purpose of the inspection is to determine if an individual is in a hazardous position with respect to the train. In this article, we determine the extent to which high-contrast visual acuity can predict performance on a simulated task. Performance at discriminating hazardous from safe conditions, as depicted in projected photographic slides, was determined as a function of visual acuity. For different levels of visual acuity, which was varied through the use of optical defocus, a subject was required to label scenes as hazardous or safe. Task performance was highly correlated with visual acuity as measured under conditions normally used for vision screenings (high-illumination and high-contrast): as the acuity decreases, performance at discriminating hazardous from safe scenes worsens. This empirically based methodology can be used to establish a corrected high-contrast visual acuity standard for safety-sensitive work in transportation that is linked to the performance of a job-critical task.
Denehy, Linda; Hornsby, Whitney E; Herndon, James E; Thomas, Samantha; Ready, Neal E; Granger, Catherine L; Valera, Lauren; Kenjale, Aarti A; Eves, Neil D; Jones, Lee W
2013-12-01
To investigate the prognostic utility of the body mass index, severity of airflow obstruction, measures of exertional dyspnea, and exercise capacity (BODE) index in patients with inoperable non-small-cell lung cancer (NSCLC). One hundred consecutive patients with inoperable NSCLC and performance status 0 to 3 completed pulmonary function testing, the modified Medical Research Council dyspnea scale, a 6-minute walk test, and body mass index-the multidimensional 10-point BODE index. Cox proportional models were used to estimate the risk of all-cause mortality according to the BODE index with or without adjustment for traditional prognostic factors. Median follow-up was 31.5 months; 61 deaths (61%) were reported during this period. There was a significant univariate association between the BODE index score and mortality (adjusted p(trend) = 0.027). Compared with patients with a BODE index of 0, the adjusted hazard ratio for risk of death was 1.37 (95% confidence interval [CI], 0.74-2.55) for a BODE index of 1, 1.22 (95% CI, 0.45-3.25) for a BODE index of 2, and 2.44 (95% CI, 1.19-4.99) for a BODE index more than 2. The BODE index provided incremental prognostic information beyond that provided traditional markers of prognosis (adjusted p(trend) = 0.051). Every one-point increase in the BODE index, the risk of death increased by 25% (hazard ratio = 1.25; 95% CI, 1.27-4.64). The BODE index is a strong independent predictor of survival in inoperable NSCLC beyond traditional risk factors. Use of this multidimensional tool may improve risk stratification and prognostication in NSCLC.
Chen, Xuanmao; Xia, Zhengui; Storm, Daniel R.
2012-01-01
Cilia of olfactory sensory neurons (OSN) are the primary sensory organelles for olfaction. The detection of odorants by the main olfactory epithelium (MOE) depends on coupling of odorant receptors to the type 3 adenylyl cyclase (AC3) in olfactory cilia. We monitored the effect of airflow on electro-olfactogram (EOG) responses and found that the MOE of mice can sense mechanical forces generated by airflow. The airflow-sensitive EOG response in the MOE was attenuated when cAMP was increased by odorants or by forskolin suggesting a common mechanism for airflow and odorant detection. In addition, the sensitivity to airflow was significantly impaired in the MOE from AC3−/− mice. We conclude that AC3 in the MOE is required for detecting the mechanical force of airflow, which in turn may regulate odorant perception during sniffing. PMID:23136416
Estimating Engine Airflow in Gas-Turbine Powered Aircraft with Clean and Distorted Inlet Flows
NASA Technical Reports Server (NTRS)
Williams, J. G.; Steenken, W. G.; Yuhas, A. J.
1996-01-01
The P404-GF-400 Powered F/A-18A High Alpha Research Vehicle (HARV) was used to examine the impact of inlet-generated total-pressure distortion on estimating levels of engine airflow. Five airflow estimation methods were studied. The Reference Method was a fan corrected airflow to fan corrected speed calibration from an uninstalled engine test. In-flight airflow estimation methods utilized the average, or individual, inlet duct static- to total-pressure ratios, and the average fan-discharge static-pressure to average inlet total-pressure ratio. Correlations were established at low distortion conditions for each method relative to the Reference Method. A range of distorted inlet flow conditions were obtained from -10 deg. to +60 deg. angle of attack and -7 deg. to +11 deg. angle of sideslip. The individual inlet duct pressure ratio correlation resulted in a 2.3 percent airflow spread for all distorted flow levels with a bias error of -0.7 percent. The fan discharge pressure ratio correlation gave results with a 0.6 percent airflow spread with essentially no systematic error. Inlet-generated total-pressure distortion and turbulence had no significant impact on the P404-GE400 engine airflow pumping. Therefore, a speed-flow relationship may provide the best airflow estimate for a specific engine under all flight conditions.
Review on airflow in unsaturated zones induced by natural forcings
NASA Astrophysics Data System (ADS)
Kuang, Xingxing; Jiao, Jiu Jimmy; Li, Hailong
2013-10-01
Subsurface airflow in unsaturated zones induced by natural forcings is of importance in many environmental and engineering fields, such as environmental remediation, water infiltration and groundwater recharge, coastal soil aeration, mine and tunnel ventilation, and gas exchange between soil and atmosphere. This review synthesizes the published literature on subsurface airflow driven by natural forcings such as atmospheric pressure fluctuations, topographic effect, water table fluctuations, and water infiltration. The present state of knowledge concerning the mechanisms, analytical and numerical models, and environmental and engineering applications related to the naturally occurring airflow is discussed. Airflow induced by atmospheric pressure fluctuations is studied the most because of the applications to environmental remediation and transport of trace gases from soil to atmosphere, which are very important in understanding biogeochemical cycling and global change. Airflow induced by infiltration is also an extensively investigated topic because of its implications in rainfall infiltration and groundwater recharge. Airflow induced by water table fluctuations is important in coastal areas because it plays an important role in coastal environmental remediation and ecological systems. Airflow induced by topographic effect is studied the least. However, it has important applications in unsaturated zone gas transport and natural ventilation of mines and tunnels. Finally, the similarities and differences in the characteristics of the air pressure and airflow are compared and future research efforts are recommended.
Cao, Guangyu; Storås, Madeleine C A; Aganovic, Amar; Stenstad, Liv-Inger; Skogås, Jan Gunnar
2018-05-04
Airflow distribution in the operating room plays an important role in ensuring a clean operating microenvironment and preventing surgical site infections (SSIs) caused by airborne contaminations. The objective of this study was to characterize the airflow distribution in proximity to a patient in an orthopedic operating room. Experimental measurements were conducted in a real operating room at St. Olav's Hospital, Norway, with a laminar airflow system. Omnidirectional anemometers were used to investigate the air distribution in the operating zone, and 4 different cases were examined with a real person and a thermal manikin. This study showed that the downward airflow from the laminar airflow system varies in each case with different surgical arrangement, such as the position of the operating lamp. The results indicate that the interaction of thermal plumes from a patient and the downward laminar airflow may dominate the operating microenvironment. The airflow distribution in proximity to a patient is influenced by both the surgical facility and the presence of medical staff. A thermal manikin may be an economical and practical way to study the interaction of thermal plumes and downward laminar airflow. The provision of higher clean airflow rate in the operating microenvironment may be an effective way to prevent the development of SSIs caused by indoor airborne contamination. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Aerodynamic tricks for pitching oscillation and visual stabilization in a hovering bird
NASA Astrophysics Data System (ADS)
Su, Jian-Yuan; Ting, Shang-Chieh; Yang, Jing-Tang
2010-11-01
We experimentally investigate how small birds attain a stabilized vision and body posture during hovering. Wing-beats of finches and passerines executing asymmetrical hovering provide lift merely during the downstroke. The downstroke lift is significantly greater than the bird weight, thereby causing a pitch-up swing of the bird body. A hovering bird skillfully and unceasingly tunes the position and orientation of lift force to stabilize its vision, so that the eye displacement is approximately one-tenth less than the tail, causing an illusion that the bird body is rotating about the eye. The hovering birds also spread and fold periodically their tail with an evident phase relationship with respect to the beating wings. We found that hovering birds use their tail to intercept the strong downward air-flow induced by the downstroking wings, and sophisticatedly spread their tail upon the arrival of the downward air-flow, rendering a pitch-up moment that effectively counteracts the pitch-down body rotation. Hence during hovering the bird essentially undergoes a dynamically-stable pitching oscillation, and concurrently attains a stabilized vision.
Effect of glaucoma on eye movement patterns and laboratory-based hazard detection ability
Black, Alex A.; Wood, Joanne M.
2017-01-01
Purpose The mechanisms underlying the elevated crash rates of older drivers with glaucoma are poorly understood. A key driving skill is timely detection of hazards; however, the hazard detection ability of drivers with glaucoma has been largely unexplored. This study assessed the eye movement patterns and visual predictors of performance on a laboratory-based hazard detection task in older drivers with glaucoma. Methods Participants included 30 older drivers with glaucoma (71±7 years; average better-eye mean deviation (MD) = −3.1±3.2 dB; average worse-eye MD = −11.9±6.2 dB) and 25 age-matched controls (72±7 years). Visual acuity, contrast sensitivity, visual fields, useful field of view (UFoV; processing speeds), and motion sensitivity were assessed. Participants completed a computerised Hazard Perception Test (HPT) while their eye movements were recorded using a desk-mounted Tobii TX300 eye-tracking system. The HPT comprises a series of real-world traffic videos recorded from the driver’s perspective; participants responded to road hazards appearing in the videos, and hazard response times were determined. Results Participants with glaucoma exhibited an average of 0.42 seconds delay in hazard response time (p = 0.001), smaller saccades (p = 0.010), and delayed first fixation on hazards (p<0.001) compared to controls. Importantly, larger saccades were associated with faster hazard responses in the glaucoma group (p = 0.004), but not in the control group (p = 0.19). Across both groups, significant visual predictors of hazard response times included motion sensitivity, UFoV, and worse-eye MD (p<0.05). Conclusions Older drivers with glaucoma had delayed hazard response times compared to controls, with associated changes in eye movement patterns. The association between larger saccades and faster hazard response time in the glaucoma group may represent a compensatory behaviour to facilitate improved performance. PMID:28570621
Visual Computing Environment Workshop
NASA Technical Reports Server (NTRS)
Lawrence, Charles (Compiler)
1998-01-01
The Visual Computing Environment (VCE) is a framework for intercomponent and multidisciplinary computational simulations. Many current engineering analysis codes simulate various aspects of aircraft engine operation. For example, existing computational fluid dynamics (CFD) codes can model the airflow through individual engine components such as the inlet, compressor, combustor, turbine, or nozzle. Currently, these codes are run in isolation, making intercomponent and complete system simulations very difficult to perform. In addition, management and utilization of these engineering codes for coupled component simulations is a complex, laborious task, requiring substantial experience and effort. To facilitate multicomponent aircraft engine analysis, the CFD Research Corporation (CFDRC) is developing the VCE system. This system, which is part of NASA's Numerical Propulsion Simulation System (NPSS) program, can couple various engineering disciplines, such as CFD, structural analysis, and thermal analysis.
Sul, Bora; Oppito, Zachary; Jayasekera, Shehan; Vanger, Brian; Zeller, Amy; Morris, Michael; Ruppert, Kai; Altes, Talissa; Rakesh, Vineet; Day, Steven; Robinson, Risa; Reifman, Jaques; Wallqvist, Anders
2018-05-01
Computational models are useful for understanding respiratory physiology. Crucial to such models are the boundary conditions specifying the flow conditions at truncated airway branches (terminal flow rates). However, most studies make assumptions about these values, which are difficult to obtain in vivo. We developed a computational fluid dynamics (CFD) model of airflows for steady expiration to investigate how terminal flows affect airflow patterns in respiratory airways. First, we measured in vitro airflow patterns in a physical airway model, using particle image velocimetry (PIV). The measured and computed airflow patterns agreed well, validating our CFD model. Next, we used the lobar flow fractions from a healthy or chronic obstructive pulmonary disease (COPD) subject as constraints to derive different terminal flow rates (i.e., three healthy and one COPD) and computed the corresponding airflow patterns in the same geometry. To assess airflow sensitivity to the boundary conditions, we used the correlation coefficient of the shape similarity (R) and the root-mean-square of the velocity magnitude difference (Drms) between two velocity contours. Airflow patterns in the central airways were similar across healthy conditions (minimum R, 0.80) despite variations in terminal flow rates but markedly different for COPD (minimum R, 0.26; maximum Drms, ten times that of healthy cases). In contrast, those in the upper airway were similar for all cases. Our findings quantify how variability in terminal and lobar flows contributes to airflow patterns in respiratory airways. They highlight the importance of using lobar flow fractions to examine physiologically relevant airflow characteristics.
Kim, Hyun Jung; Baek, Seunghee; Kim, Hee Jin; Lee, Jae Seung; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Sei Won
2015-01-01
Background Although smoking is the most important and modifiable cause of chronic obstructive pulmonary disease (COPD), other risk factors including asthma and tuberculosis (TB) are also associated. It is common for COPD patients to have more than one of these risk factors. The aims of this study were to determine the prevalence of airflow limitation (FEV1/FVC<0.7) according to the risk factors and to investigate their impact and interaction in airflow limitation. Methods From the Korean National Health and Nutrition Examination Survey between 2008 and 2012, we analyzed participants over 40 years of age by spirometry, chest radiograph and questionnaire about asthma and smoking history. Results Of 12,631 participants, 1,548 (12.3%) had airflow limitation. The prevalence of airflow limitation in smokers (≥10 pack-year), asthmatics, and those with inactive TB was 23.9%, 32.1%, and 33.6%. The prevalence increased with the number of risk factors: 86.1% had airflow limitation if they had all three risk factors. Impacts of inactive TB and asthma on airflow limitation were equivalent to 47 and 69 pack-years of smoking, respectively. Airflow limitation resulted from lower levels of smoking in those with inactive TB and asthma. A potential interaction between smoking and inactive tuberculosis in the development of airflow limitation was identified (p = 0.054). Conclusions Asthma and inactive TB lesions increase susceptibility to smoking in the development of airflow limitation. People with these risk factors should be seen as a major target population for anti-smoking campaigns to prevent COPD. PMID:25915938
Vortex dipolar structures in a rigid model of the larynx at flow onset
NASA Astrophysics Data System (ADS)
Chisari, N. E.; Artana, G.; Sciamarella, D.
2011-02-01
Starting jet airflow is investigated in a channel with a pair of consecutive slitted constrictions approximating the true and false vocal folds in the human larynx. The flow is visualized using the Schlieren optical technique and simulated by solving the Navier-Stokes equations for an incompressible two-dimensional viscous flow. Laboratory and numerical experiments show the spontaneous formation of three different classes of vortex dipolar structures in several regions of the laryngeal profile under conditions that may be assimilated to those of voice onset.
NASA Technical Reports Server (NTRS)
Robelen, David B. (Inventor)
1996-01-01
A device for producing a stream of vapor for wind tunnel airflow visualization is described. An electrically conductive heating tube is used to resistively heat a vapor producing liquid. The heating and delivery systems are integrated to allow the device to present a small cross section to the air flow, thereby reducing disturbances due to the device. The simplicity of the design allows for inexpensive implementation and construction. The design is readily scaled for use in various wind tunnel applications. The device may also find uses in manufacturing, producing a vapor for deposition on a substrate.
Experimental Investigation of the Induced Airflow of Corona Discharge
NASA Astrophysics Data System (ADS)
Huang, Yong; Zhang, Xin; Wang, Xun-Nian; Wang, Wan-Bo; Huang, Zong-Bo; Li, Hua-Xing
2013-09-01
In order to improve the acceleration effect of corona discharge acting on air, we present an experimental study on the induced airflow produced by corona discharge between two parallel electrodes. The parameters investigated are the type of electrodes, actuation voltage and the distance in the absence of free airflow. The induced flow velocity is measured directly in the accelerated region using the particle image velocimetry technology. The results show that if corona discharge is not developed into arc discharge, the induced airflow velocity increases nearly linearly with the applied voltage and the maximum induced airflow velocity near the needle electrode reaches 36 m/s. It is expected that in the future, the result can be referred to in the research about effect of active flow control to reach much higher induced airflow speed.
Piezoelectric sensing: Evaluation for clinical investigation of deviated nasal septum
Manjunatha, Roopa G.; Mahapatra, Roy D.; Dorasala, Srinivas
2013-01-01
Noninvasive objective evaluation of nasal airflow is one of the important clinical aspects. The developed polyvinylidene fluoride (PVDF) sensor enables measurement of airflow through each side of the nose using its piezoelectric property. This study was designed to evaluate the diagnostic capability of the PVDF sensor in assessing the deviated nasal septum (DNS). PVDF nasal sensor uses its piezoelectric property to measure the peak-to-peak amplitude (Vp-p) of nasal airflow in both of the nostrils: right nostril (RN) and left nostril (LN), separately and simultaneously. We have compared the results of PVDF nasal sensor, visual analog scale (VAS), and clinician scale for 34 DNS patients and 28 healthy controls. Additionally, the results were further analyzed by receiver operating characteristic curve and correlation between PVDF nasal sensor and VAS in detecting DNS. We found a significant difference in the peak-to-peak amplitude values of the test group and the control group. The correlation between the PVDF nasal sensor measurements and VAS (RN and LN combined) for test group was statistically significant (−0.807; p < 0.001). Sensitivity and specificity of the PVDF nasal sensor measurements in the detection of DNS (RN and LN combined) was 85.3 and 74.4%, respectively, with optimum cutoff value ≤0.34 Vp-p. The developed PVDF nasal sensor is noninvasive and requires less patient efforts. The sensitivity and specificity of the PVDF nasal sensor are reliable. According to our findings, we propose that the said PVDF nasal sensor can be used as a new diagnostic tool to evaluate the DNS in routine clinical practice. PMID:24498519
[Bronchiolitis with airflow obstruction in adults].
Fournier, M; Marceau, A; Dauriat, G; Camuset, J; Groussard, O
2004-04-01
The purpose of this paper is twofold: to describe the clinical and anatomical characteristics of bronchiolitis associated with airflow obstruction in adults; to present through a clinical approach, a classification of the main aetiologies or pathological frames associated with that entity. The constrictive bronchiolitis type is the most frequently encountered. On clinical grounds, cough, crackles, and a progressive dyspnea develop usually within a few weeks. Radiological signs of bronchiolar abnormalities are best visualized on high resolution expiratory CT scan. The decrease in maximal airflows and oxygen tension is of limited amplitude and poorly reversible with bronchodilators. Diagnosis is easily performed when a causative event, or the clinical context, can be delineated: inhalation of toxic fumes, diffuse bronchiectasis, rheumatoid arthritis, lung or bone marrow transplantation. Delayed formation of bronchiectasis in the central airways is common. The treatment is not standardized; corticosteroids are usually prescribed as a first line therapy; the benefit of the addition of, or substitution with immunosuppressive drugs has not been adequately evaluated, but is, on the mean, of limited amplitude. Recent advances in the identification of inhaled agents toxic for the distal airways help in establishing appropriate measures of prevention. When the aetiology of the bronchiolitis cannot be suspected, extensive search of a causative agent should be performed, including microbial and mineral analysis of bronchoalveolar products. Negative results should lead to perform a surgical lung biopsy. The study of chronic rejection processes in animal models of lung transplantation, the identification of inhibitory factors of bronchiolar fibrogenesis, and the efficacy of some anti-cytokines on inflammatory processes could result in new therapeutic approaches.
Gunter, Stacey A; Bradford, James A; Moffet, Corey A
2017-01-01
Methane (CH) and carbon dioxide (CO) represent 11 and 81%, respectively, of all anthropogenic greenhouse gas emissions. Agricultural CH emissions account for approximately 43% of all anthropogenic CH emissions. Most agricultural CH emissions are attributed to enteric fermentation within ruminant livestock; hence, the heightened interest in quantifying and mitigating this source. The automated, open-circuit gas quantification system (GQS; GreenFeed, C-Lock, Inc., Rapid City, SD) evaluated here can be placed in a pasture with grazing cattle and can measure their CH and CO emissions with spot sampling. However, improper management of the GQS can have an erroneous effect on emission estimates. One factor affecting the quality of emission estimates is the airflow rates through the GQS to ensure a complete capture of the breath cloud emitted by the animal. It is hypothesized that at lower airflow rates this cloud will be incompletely captured. To evaluate the effect of airflow rate through the GQS on emission estimates, a data set was evaluated with 758 CO and CH emission estimates with a range in airflows of 10.7 to 36.6 L/s. When airflow through the GQS was between 26.0 and 36.6 L/s, CO and CH emission estimates were not affected ( = 0.14 and 0.05, respectively). When airflow rates were less than 26.0 L/s, CO and CH emission estimates were lower and decreased as airflow rate decreased ( < 0.0001). We hypothesize that when airflow through the GQS decreases below 26 L/s, breath capture was incomplete and CO and CH emissions are underestimated. Maintaining mass airflow through a GQS at rates greater than 26 L/s is important for producing high quality CO and CH emission estimates.
B-1 AFT Nacelle Flow Visualization Study
NASA Technical Reports Server (NTRS)
Celniker, Robert
1975-01-01
A 2-month program was conducted to perform engineering evaluation and design tasks to prepare for visualization and photography of the airflow along the aft portion of the B-1 nacelles and nozzles during flight test. Several methods of visualizing the flow were investigated and compared with respect to cost, impact of the device on the flow patterns, suitability for use in the flight environment, and operability throughout the flight. Data were based on a literature search and discussions with the test personnel. Tufts were selected as the flow visualization device in preference to several other devices studied. A tuft installation pattern has been prepared for the right-hand aft nacelle area of B-1 air vehicle No.2. Flight research programs to develop flow visualization devices other than tufts for use in future testing are recommended. A design study was conducted to select a suitable motion picture camera, to select the camera location, and to prepare engineering drawings sufficient to permit installation of the camera. Ten locations on the air vehicle were evaluated before the selection of the location in the horizontal stabilizer actuator fairing. The considerations included cost, camera angle, available volume, environmental control, flutter impact, and interference with antennas or other instrumentation.
Quantifying Fall-Related Hazards in the Homes of Persons with Glaucoma.
Yonge, Andrea V; Swenor, Bonnielin K; Miller, Rhonda; Goldhammer, Victoria; West, Sheila K; Friedman, David S; Gitlin, Laura N; Ramulu, Pradeep Y
2017-04-01
To characterize fall-related hazards in the homes of persons with suspected or diagnosed glaucoma, and to determine whether those with worse visual field (VF) damage have fewer home hazards. Cross-sectional study using baseline (2013-2015) data from the ongoing Falls in Glaucoma Study (FIGS). One-hundred seventy-four of 245 (71.0%) FIGS participants agreeing to the home assessment. Participants' homes were assessed using the Home Environment Assessment for the Visually Impaired (HEAVI). A single evaluator assessed up to 127 potential hazards in 8 home regions. In the clinic, binocular contrast sensitivity (CS) and better-eye visual acuity (VA) were evaluated, and 24-2 VFs were obtained to calculate average integrated VF (IVF) sensitivity. Total number of home hazards. No significant visual or demographic differences were noted between participants who did and did not complete the home assessment (P > 0.09 for all measures). Mean age among those completing the home assessment (n = 174) was 71.1 years, and IVF sensitivity ranged from 5.6 to 33.4 dB (mean = 27.2 dB, standard deviation [SD] = 4.0 dB). The mean number of items graded per home was 85.2 (SD = 13.2), and an average of 32.7 (38.3%) were identified as hazards. IVF sensitivity, CS, and VA were not associated with total home hazards or the number of hazards in any given room (P > 0.06 for all visual measures and rooms). The bathroom contained the greatest number of hazards (mean = 7.9; 54.2% of graded items classified as hazardous), and the most common hazards identified in at least 1 room were ambient lighting <300 lux and exposed light bulbs. Only 27.9% of graded rooms had adequate lighting. IVF sensitivity, CS, and VA were not associated with home lighting levels (P > 0.18 for all), but brighter room lighting was noted in the homes of participants with higher median income (P < 0.001). Multiple home fall hazards were identified in the study population, and hazard numbers were not lower for persons with worse VF damage, suggesting that individuals with more advanced glaucoma do not adapt their homes for safety. Further work should investigate whether addressing home hazards is an effective intervention for preventing falls in this high-risk group. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Shen, H; Xu, Y; Dickinson, B T
2014-11-18
Inspired by sensing strategies observed in birds and bats, a new attitude control concept of directly using real-time pressure and shear stresses has recently been studied. It was shown that with an array of onboard airflow sensors, small unmanned aircraft systems can promptly respond to airflow changes and improve flight performances. In this paper, a mapping function is proposed to compute aerodynamic moments from the real-time pressure and shear data in a practical and computationally tractable formulation. Since many microscale airflow sensors are embedded on the small unmanned aircraft system surface, it is highly possible that certain sensors may fail. Here, an adaptive control system is developed that is robust to sensor failure as well as other numerical mismatches in calculating real-time aerodynamic moments. The advantages of the proposed method are shown in the following simulation cases: (i) feedback pressure and wall shear data from a distributed array of 45 airflow sensors; (ii) 50% failure of the symmetrically distributed airflow sensor array; and (iii) failure of all the airflow sensors on one wing. It is shown that even if 50% of the airflow sensors have failures, the aircraft is still stable and able to track the attitude commands.
Dols, W Stuart; Emmerich, Steven J; Polidoro, Brian J
2016-08-01
Building modelers need simulation tools capable of simultaneously considering building energy use, airflow and indoor air quality (IAQ) to design and evaluate the ability of buildings and their systems to meet today's demanding energy efficiency and IAQ performance requirements. CONTAM is a widely-used multizone building airflow and contaminant transport simulation tool that requires indoor temperatures as input values. EnergyPlus is a prominent whole-building energy simulation program capable of performing heat transfer calculations that require interzone and infiltration airflows as input values. On their own, each tool is limited in its ability to account for thermal processes upon which building airflow may be significantly dependent and vice versa. This paper describes the initial phase of coupling of CONTAM with EnergyPlus to capture the interdependencies between airflow and heat transfer using co-simulation that allows for sharing of data between independently executing simulation tools. The coupling is accomplished based on the Functional Mock-up Interface (FMI) for Co-simulation specification that provides for integration between independently developed tools. A three-zone combined heat transfer/airflow analytical BESTEST case was simulated to verify the co-simulation is functioning as expected, and an investigation of a two-zone, natural ventilation case designed to challenge the coupled thermal/airflow solution methods was performed.
Noise and contrast comparison of visual and infrared images of hazards as seen inside an automobile
NASA Astrophysics Data System (ADS)
Meitzler, Thomas J.; Bryk, Darryl; Sohn, Eui J.; Lane, Kimberly; Bednarz, David; Jusela, Daniel; Ebenstein, Samuel; Smith, Gregory H.; Rodin, Yelena; Rankin, James S., II; Samman, Amer M.
2000-06-01
The purpose of this experiment was to quantitatively measure driver performance for detecting potential road hazards in visual and infrared (IR) imagery of road scenes containing varying combinations of contrast and noise. This pilot test is a first step toward comparing various IR and visual sensors and displays for the purpose of an enhanced vision system to go inside the driver compartment. Visible and IR road imagery obtained was displayed on a large screen and on a PC monitor and subject response times were recorded. Based on the response time, detection probabilities were computed and compared to the known time of occurrence of a driving hazard. The goal was to see what combinations of sensor, contrast and noise enable subjects to have a higher detection probability of potential driving hazards.
[Phonatory airflow in the supraglottal space].
Müsebeck, K; Rosenberg, H
1983-05-01
The phonatory airflow can be measured by means of a hot wire tube placed in the supraglottic space without tying down the tongue. The velocity of airflow above the glottis reaches values around c = 50 to 150 cm/s. The variations in airflow oscillations were recorded. The voice of the person under examination was picked up by a condenser microphone (Bruel & Kjaer No. 2112). According to D'Alembert's wave equation, the sound intensity is related to the velocity of the phonatory air stream. The validity of this statement has been confirmed by repeated testing. The fundamental frequency of voice and of the airflow were analysed synchronously by means of the Nicolet analyser. The air consumption is not utilized for sound production in phonation by breathing. A "hard" or "pressed" voice is associated with diminished or irregular air consumption. The method can be employed in assessing the conditions of phonetic airflow in normal and dysphonic voices.
Airflow attenuation and bed net utilization: observations from Africa and Asia.
von Seidlein, Lorenz; Ikonomidis, Konstantin; Bruun, Rasmus; Jawara, Musa; Pinder, Margaret; Knols, Bart Gj; Knudsen, Jakob B
2012-06-15
Qualitative studies suggest that bed nets affect the thermal comfort of users. To understand and reduce this discomfort the effect of bed nets on temperature, humidity, and airflow was measured in rural homes in Asia and Africa, as well as in an experimental wind tunnel. Two investigators with architectural training selected 60 houses in The Gambia, Tanzania, Philippines, and Thailand. Data-loggers were used to measure indoor temperatures in hourly intervals over a 12 months period. In a subgroup of 20 houses airflow, temperature and humidity were measured at five-minute intervals for one night from 21.00 to 6.00 hrs inside and outside of bed nets using sensors and omni-directional thermo-anemometers. An investigator set up a bed net with a mesh size of 220 holes per inch 2 in each study household and slept under the bed net to simulate a realistic environment. The attenuation of airflow caused by bed nets of different mesh sizes was also measured in an experimental wind tunnel. The highest indoor temperatures (49.0 C) were measured in The Gambia. During the hottest months of the year the mean temperature at night (9 pm) was between 33.1 C (The Gambia) and 26.2 C (Thailand). The bed net attenuated the airflow from a minimum of 27% (Philippines) to a maximum of 71% (The Gambia). Overall the bed nets reduced airflow compared to un-attenuated airflow from 9 to 4 cm sec-1 or 52% (p<0.001). In all sites, no statistically significant difference in temperature or humidity was detected between the inside and outside of the bed net. Wind tunnel experiments with 11 different mesh-sized bed nets showed an overall reduction in airflow of 64% (range 55 - 71%) compared to un-attenuated airflow. As expected, airflow decreased with increasing net mesh size. Nets with a mesh of 136 holes inch-2 reduced airflow by 55% (mean; range 51 - 73%). A denser net (200 holes inch-2) attenuated airflow by 59% (mean; range 56 - 74%). Despite concerted efforts to increase the uptake of this intervention in many areas uptake remains poor. Bed nets reduce airflow, but have no influence on temperature and humidity. The discomfort associated with bed nets is likely to be most intolerable during the hottest and most humid period of the year, which frequently coincides with the peak of malaria vector densities and the force of pathogen transmission. These observations suggest thermal discomfort is a factor limiting bed net use and open a range of architectural possibilities to overcome this limitation.
Signs of Gas Trapping in Normal Lung Density Regions in Smokers.
Bodduluri, Sandeep; Reinhardt, Joseph M; Hoffman, Eric A; Newell, John D; Nath, Hrudaya; Dransfield, Mark T; Bhatt, Surya P
2017-12-01
A substantial proportion of subjects without overt airflow obstruction have significant respiratory morbidity and structural abnormalities as visualized by computed tomography. Whether regions of the lung that appear normal using traditional computed tomography criteria have mild disease is not known. To identify subthreshold structural disease in normal-appearing lung regions in smokers. We analyzed 8,034 subjects with complete inspiratory and expiratory computed tomographic data participating in the COPDGene Study, including 103 lifetime nonsmokers. The ratio of the mean lung density at end expiration (E) to end inspiration (I) was calculated in lung regions with normal density (ND) by traditional thresholds for mild emphysema (-910 Hounsfield units) and gas trapping (-856 Hounsfield units) to derive the ND-E/I ratio. Multivariable regression analysis was used to measure the associations between ND-E/I, lung function, and respiratory morbidity. The ND-E/I ratio was greater in smokers than in nonsmokers, and it progressively increased from mild to severe chronic obstructive pulmonary disease severity. A proportion of 26.3% of smokers without airflow obstruction had ND-E/I greater than the 90th percentile of normal. ND-E/I was independently associated with FEV 1 (adjusted β = -0.020; 95% confidence interval [CI], -0.032 to -0.007; P = 0.001), St. George's Respiratory Questionnaire scores (adjusted β = 0.952; 95% CI, 0.529 to 1.374; P < 0.001), 6-minute-walk distance (adjusted β = -10.412; 95% CI, -12.267 to -8.556; P < 0.001), and body mass index, airflow obstruction, dyspnea, and exercise capacity index (adjusted β = 0.169; 95% CI, 0.148 to 0.190; P < 0.001), and also with FEV 1 change at follow-up (adjusted β = -3.013; 95% CI, -4.478 to -1.548; P = 0.001). Subthreshold gas trapping representing mild small airway disease is prevalent in normal-appearing lung regions in smokers without airflow obstruction, and it is associated with respiratory morbidity. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).
Visual motion perception predicts driving hazard perception ability.
Lacherez, Philippe; Au, Sandra; Wood, Joanne M
2014-02-01
To examine the basis of previous findings of an association between indices of driving safety and visual motion sensitivity and to examine whether this association could be explained by low-level changes in visual function. A total of 36 visually normal participants (aged 19-80 years) completed a battery of standard vision tests including visual acuity, contrast sensitivity and automated visual fields and two tests of motion perception including sensitivity for movement of a drifting Gabor stimulus and sensitivity for displacement in a random dot kinematogram (Dmin ). Participants also completed a hazard perception test (HPT), which measured participants' response times to hazards embedded in video recordings of real-world driving, which has been shown to be linked to crash risk. Dmin for the random dot stimulus ranged from -0.88 to -0.12 log minutes of arc, and the minimum drift rate for the Gabor stimulus ranged from 0.01 to 0.35 cycles per second. Both measures of motion sensitivity significantly predicted response times on the HPT. In addition, while the relationship involving the HPT and motion sensitivity for the random dot kinematogram was partially explained by the other visual function measures, the relationship with sensitivity for detection of the drifting Gabor stimulus remained significant even after controlling for these variables. These findings suggest that motion perception plays an important role in the visual perception of driving-relevant hazards independent of other areas of visual function and should be further explored as a predictive test of driving safety. Future research should explore the causes of reduced motion perception to develop better interventions to improve road safety. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
El Merhie, Amira; Navarro, Laurent; Delavenne, Xavier; Leclerc, Lara; Pourchez, Jérémie
2016-05-01
Enhancement of intranasal sinus deposition involves nebulization of a drug superimposed by an acoustic airflow. We investigated the impact of fixed frequency versus frequency sweep acoustic airflow on the improvement of aerosolized drug penetration into maxillary sinuses. Fixed frequency and frequency sweep acoustic airflow were generated using a nebulizing system of variable frequency. The effect of sweep cycle and intensity variation was studied on the intranasal sinus deposition. We used a nasal replica created from CT scans using 3D printing. Sodium fluoride and gentamicin were chosen as markers. Studies performed using fixed frequency acoustic airflow showed that each of maxillary sinuses of the nasal replica required specific frequency for the optimal aerosol deposition. Intranasal sinus drug deposition experiments under the effect of the frequency sweep acoustic airflow showed an optimal aerosol deposition into both maxillary sinus of the nasal replica. Studies on the effect of the duration of the sweep cycle showed that the shorter the cycle the better the deposition. We demonstrate the benefit of frequency sweep acoustic airflow on drug deposition into maxillary sinuses. However further in vivo studies have to be conducted since delivery rates cannot be obviously determined from a nasal replica.
Spits, Christine; Wallace, Luke; Reinke, Karin
2017-04-20
Visual assessment, following guides such as the Overall Fuel Hazard Assessment Guide (OFHAG), is a common approach for assessing the structure and hazard of varying bushfire fuel layers. Visual assessments can be vulnerable to imprecision due to subjectivity between assessors, while emerging techniques such as image-based point clouds can offer land managers potentially more repeatable descriptions of fuel structure. This study compared the variability of estimates of surface and near-surface fuel attributes generated by eight assessment teams using the OFHAG and Fuels3D, a smartphone method utilising image-based point clouds, within three assessment plots in an Australian lowland forest. Surface fuel hazard scores derived from underpinning attributes were also assessed. Overall, this study found considerable variability between teams on most visually assessed variables, resulting in inconsistent hazard scores. Variability was observed within point cloud estimates but was, however, on average two to eight times less than that seen in visual estimates, indicating greater consistency and repeatability of this method. It is proposed that while variability within the Fuels3D method may be overcome through improved methods and equipment, inconsistencies in the OFHAG are likely due to the inherent subjectivity between assessors, which may be more difficult to overcome. This study demonstrates the capability of the Fuels3D method to efficiently and consistently collect data on fuel hazard and structure, and, as such, this method shows potential for use in fire management practices where accurate and reliable data is essential.
In-depth survey report of American Airlines plating facility
NASA Astrophysics Data System (ADS)
Mortimer, V. D., Jr.
1982-12-01
An in depth survey was conducted at the American Airlines Maintenance and Engineering Center as part of National Institute for Occupational Safety and Health (NIOSH) study evaluating measures to control occupational health hazards associated with the metal plating industry. This American Airlines plating facility, employing approximately 25 workers, is primarily engaged in plating hard chromium, nickel and cadmium on aircraft engine and landing gear parts. Six tanks were studied, including an electroless nickel tank. Area and personal samples for chromium, nickel, cadmium, and cyanide were collected. Ventilation airflow and tank dimensions were measured and data recorded on plating operations. The relationships between air contaminants emitted, local exhaust ventilation flow rate, tank size, and plating activity were evaluated.
Laniewicz, Cheryl
2017-01-01
On July 1, 2018, United States Pharmacopeia <800> takes effect in those states that adopt it, and the discussion within this article may be applicable to those states that develop their own standards. United States Pharmacopeia <800> changes requirements for storage and compounding of hazardous drugs. The new requirements have important implications for air management and ventilation in some pharmacies. This article discusses how United States Pharmacopeia <800> compares to United States Pharmacopeia <797>, how the changes impact room ventilation and pressurization requirements, and how high-performance airflow control systems that ensure compliance and safety are impacted. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Disposable Electronic Cigarettes and Electronic Hookahs: Evaluation of Performance
Williams, Monique; Ghai, Sanjay
2015-01-01
Introduction: The purpose of this study was to characterize the performance of disposable button-activated and disposable airflow-activated electronic cigarettes (EC) and electronic hookahs (EH). Methods: The airflow rate required to produce aerosol, pressure drop, and the aerosol absorbance at 420nm were measured during smoke-outs of 9 disposable products. Three units of each product were tested in these experiments. Results: The airflow rates required to produce aerosol and the aerosol absorbances were lower for button-activated models (3mL/s; 0.41–0.55 absorbance) than for airflow-activated models (7–17mL/s; 0.48–0.84 absorbance). Pressure drop was also lower across button-activated products (range = 6–12mm H2O) than airflow-activated products (range = 15–67mm H20). For 25 of 27 units tested, airflow did not have to be increased during smoke-out to maintain aerosol production, unlike earlier generation models. Two brands had uniform performance characteristics for all parameters, while 3 had at least 1 product that did not function normally. While button-activated models lasted 200 puffs or less and EH airflow-activated models often lasted 400 puffs, none of the models produced as many puffs as advertised. Puff number was limited by battery life, which was shorter in button-activated models. Conclusion: The performance of disposable products was differentiated mainly by the way the aerosol was produced (button vs airflow-activated) rather than by product type (EC vs EH). Users needed to take harder drags on airflow-activated models. Performance varied within models, and battery life limited the number of puffs. Data suggest quality control in manufacturing varies among brands. PMID:25104117
Rofail, Lydia Makarie; Wong, Keith K.H.; Unger, Gunnar; Marks, Guy B.; Grunstein, Ronald R.
2010-01-01
Rationale: The most common single channel devices used for obstructive sleep apnea (OSA) screening are nasal airflow and oximetry. No studies have directly compared their role in diagnosing OSA at home. Study Objectives: To prospectively compare the diagnostic utility of home-based nasal airflow and oximetry to attended polysomnography (PSG) and to assess the diagnostic value of adding oximetry to nasal airflow for OSA. Design: Cross-sectional study Setting: Laboratory and home Participants: Sleep clinic patients with suspected OSA. Interventions: All patients had laboratory PSG and 2 sets of 3 consecutive nights on each device; nasal airflow (Flow Wizard, DiagnoseIT, Australia) and oximetry (Radical Set, Masimo, USA) at home in random order. Results: Ninety-eight of the 105 patients enrolled completed home monitoring. The accuracy of nasal airflow respiratory disturbance index (NF RDI) was not different from oximetry (ODI 3%) for diagnosing OSA (area under the ROC curve (AUC) difference, 0.04; 95% CI of difference −0.05 to 0.12; P = 0.43) over 3 nights of at-home recording. The accuracy of NF RDI was higher after 3 nights compared to one night (AUC difference, 0.05; 95% CI of difference, 0.01 to 0.08; P = 0.04). Addition of oximetry to nasal airflow did not increase the accuracy for predicting OSA compared to nasal airflow alone (P > 0.1). Conclusions: Nasal flow and oximetry have equivalent accuracy for diagnosing OSA in the home setting. Choice of device for home screening of sleep apnea may depend on logistical and service delivery issues. Citation: Makarie Rofail L; Wong KKH; Unger G; Marks GB; Grunstein RR. Comparison between a single-channel nasal airflow device and oximetry for the diagnosis of obstructive sleep apnea. SLEEP 2010;33(8):1106-1114. PMID:20815194
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, Haicheng; School of Physics Science and Technology, Anshan Normal University, Anshan 114005; Fan, Zhihui
Atmospheric pressure dielectric barrier discharge plasma is produced in airflow by applying nanosecond high voltage pulses with peak voltage about 35 kV and rising time about 40 ns on a plate-to-plate electrode arrangement. The effects of airflow rate (0–50 m/s) on the discharge characteristics are investigated under different barrier conditions (the bare anode case and the bare cathode case). For both cases, the breakdown voltage and the time lag increase distinctly and the discharge intensity decreases sharply when the airflow rate increases from 0 to 30 m/s, and then keep almost constant until the airflow rate is further increased to 50 m/s. For the baremore » anode case (the cathode is covered by dielectric plate), the discharge mode transforms gradually from filamentary to diffuse discharge with the increasing airflow rate. While for the bare cathode case, some micro-discharge channels are still excited, though the discharge becomes more diffuse when the airflow rate is higher than 30 m/s. By acquiring the time-resolved images of the discharge, it is proved that it is the primary discharge which becomes diffuse when airflow is introduced and the following two discharges of the same voltage pulse occur principally at the positions where the primary discharge is more intense. And in both cases, the plasma temperatures are reduced, but the degree is different. All the phenomena can be explained mainly by the variation of the space charge distribution when the airflow is introduced into the discharge gap. And it is indicated that the bare anode case has an advantage in obtaining diffuse discharge.« less
NASA Astrophysics Data System (ADS)
Jones, Jeanne M.; Henry, Kevin; Wood, Nathan; Ng, Peter; Jamieson, Matthew
2017-12-01
The Hazard Exposure Reporting and Analytics (HERA) dynamic web application was created to provide a platform that makes research on community exposure to coastal-flooding hazards influenced by sea level rise accessible to planners, decision makers, and the public in a manner that is both easy to use and easily accessible. HERA allows users to (a) choose flood-hazard scenarios based on sea level rise and storm assumptions, (b) appreciate the modeling uncertainty behind a chosen hazard zone, (c) select one or several communities to examine exposure, (d) select the category of population or societal asset, and (e) choose how to look at results. The application is designed to highlight comparisons between (a) varying levels of sea level rise and coastal storms, (b) communities, (c) societal asset categories, and (d) spatial scales. Through a combination of spatial and graphical visualizations, HERA aims to help individuals and organizations to craft more informed mitigation and adaptation strategies for climate-driven coastal hazards. This paper summarizes the technologies used to maximize the user experience, in terms of interface design, visualization approaches, and data processing.
Jones, Jeanne M.; Henry, Kevin; Wood, Nathan J.; Ng, Peter; Jamieson, Matthew
2017-01-01
The Hazard Exposure Reporting and Analytics (HERA) dynamic web application was created to provide a platform that makes research on community exposure to coastal-flooding hazards influenced by sea level rise accessible to planners, decision makers, and the public in a manner that is both easy to use and easily accessible. HERA allows users to (a) choose flood-hazard scenarios based on sea level rise and storm assumptions, (b) appreciate the modeling uncertainty behind a chosen hazard zone, (c) select one or several communities to examine exposure, (d) select the category of population or societal asset, and (e) choose how to look at results. The application is designed to highlight comparisons between (a) varying levels of sea level rise and coastal storms, (b) communities, (c) societal asset categories, and (d) spatial scales. Through a combination of spatial and graphical visualizations, HERA aims to help individuals and organizations to craft more informed mitigation and adaptation strategies for climate-driven coastal hazards. This paper summarizes the technologies used to maximize the user experience, in terms of interface design, visualization approaches, and data processing.
Price, A; Eccles, R
2017-10-01
Left- or right-handedness is a common human trait, and it has been previously reported that human nasal airflow dominance correlates with hand dominance. Any relationship between hand dominance and nasal airflow dominance would be unusual. This study aimed to measure nasal airflow and look for any relationship to handedness. The modified Glatzel mirror was used to record the dominant nasal passage at 15-minute intervals over a 6-hour period in 29 healthy participants consisting of 15 left-handers and 14 right-handers. In left-handers, the percentage of time that the left nasal passage was dominant ranged from 0 to 100 per cent. In right-handers, the percentage of time that the right nasal passage was dominant ranged from 4.2 to 95.8 per cent. No correlation between nasal airflow dominance and hand dominance was identified. The results do not support the hypothesis that nasal airflow and handedness are related.
Kitaoka, Hiroko; Cok, Salim
2013-01-01
Adventitious lung sounds in pulmonary emphysema, wheezes, are continuous musical sounds during expiration with 400 Hz or more. The textbook tells that expiratory airflow limitation in emphysema occurs at the peripheral airways and that wheezes are generated there. We have recently proposed a novel hypothesis based on image analysis and theoretical consideration that expiratory airflow limitation in emphysema occurs at the intra-mediastinal airway (trachea, main bronchi, and right lobar bronchi) due to compression by overinflated lungs. We performed expiratory airflow simulation by the use of a 4D finite element lung model, and found periodical vortex release with 300-900 Hz at the end of protrusion of the the tracheal posterior wall. Relationship between the peak frequency of pressure fluctuation and airflow velocity was in agreement with Strahal's law either in normal or emphysematous condition. Contrarily, airflow simulation in a small bronchus (1.5 mm in diameter) indicated no apparent periodic vortex release.
Experimental Research on Optimizing Inlet Airflow of Wet Cooling Towers under Crosswind Conditions
NASA Astrophysics Data System (ADS)
Chen, You Liang; Shi, Yong Feng; Hao, Jian Gang; Chang, Hao; Sun, Feng Zhong
2018-01-01
A new approach of installing air deflectors around tower inlet circumferentially was proposed to optimize the inlet airflow and reduce the adverse effect of crosswinds on the thermal performance of natural draft wet cooling towers (NDWCT). And inlet airflow uniformity coefficient was defined to analyze the uniformity of circumferential inlet airflow quantitatively. Then the effect of air deflectors on the NDWCT performance was investigated experimentally. By contrast between inlet air flow rate and cooling efficiency, it has been found that crosswinds not only decrease the inlet air flow rate, but also reduce the uniformity of inlet airflow, which reduce NDWCT performance jointly. After installing air deflectors, the inlet air flow rate and uniformity coefficient increase, the uniformity of heat and mass transfer increases correspondingly, which improve the cooling performance. In addition, analysis on Lewis factor demonstrates that the inlet airflow optimization has more enhancement of heat transfer than mass transfer, but leads to more water evaporation loss.
Semi-parametric regression model for survival data: graphical visualization with R
2016-01-01
Cox proportional hazards model is a semi-parametric model that leaves its baseline hazard function unspecified. The rationale to use Cox proportional hazards model is that (I) the underlying form of hazard function is stringent and unrealistic, and (II) researchers are only interested in estimation of how the hazard changes with covariate (relative hazard). Cox regression model can be easily fit with coxph() function in survival package. Stratified Cox model may be used for covariate that violates the proportional hazards assumption. The relative importance of covariates in population can be examined with the rankhazard package in R. Hazard ratio curves for continuous covariates can be visualized using smoothHR package. This curve helps to better understand the effects that each continuous covariate has on the outcome. Population attributable fraction is a classic quantity in epidemiology to evaluate the impact of risk factor on the occurrence of event in the population. In survival analysis, the adjusted/unadjusted attributable fraction can be plotted against survival time to obtain attributable fraction function. PMID:28090517
Tactile Approaches for Teaching Blind and Visually-Impaired Students in the Geosciences
NASA Astrophysics Data System (ADS)
Permenter, J. L.; Runyon, C.
2003-12-01
Hearing and touch are perhaps the two most important senses for teaching visually-impaired students in any context. Classroom lectures obviously emphasize the auditory aspects of learning, while touch is often relegated to either Braille texts or raised--line drawings for illustrative figures. From the student's perspective, some lecture topics, especially in the sciences, can be a challenge to grasp without additional stimuli. Geosciences have a distinct visual component that can be lost when teaching blind or visually-impaired students, particularly in the study of geomorphology and landform change. As an example, the matters raised concerning volcanic hazards can be difficult to envision without due attention to the limitations of visually-impaired students. Here, we suggest an example of a tactile approach for introducing the study of volcanoes and the hazards associated with them. Large, visually-stimulating images of a volcanic, populated region in southern Peru are supplied for those students who have poor but extant visual acuity, while precise, clay-based models of the region complement the images for those students, as well as for students who have no visual ability whatsoever. We use a model of the terrestrial volcano El Misti and the nearby city of Arequipa, Peru, to directly reflect the volcanic morphology and hazardous aspects of the terrain. The use of computer-generated digital elevation models from remote sensing imaging systems allows accurate replication of the regional topography. Instructors are able to modify these clay models to illustrate spatial and temporal changes in the region, allowing students to better grasp potential geological and geographical transformations over time. The models spawn engaging class discussions and help with designing hazard mitigation protocols.
NASA Technical Reports Server (NTRS)
Sanders, B. W.
1980-01-01
The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with a poppet-valve-controlled stability bypass system that was designed to provide a large, stable airflow range. Propulsion system response and stability bypass performance were determined for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area as well as compressor stall. For reference, data are also included for a conventional, fixed-exit bleed system. The poppet valves greatly increased inlet stability and had no adverse effects on propulsion system performance. Limited unstarted-inlet bleed performance data are presented.
Measurement of the resistivity of porous materials with an alternating air-flow method.
Dragonetti, Raffaele; Ianniello, Carmine; Romano, Rosario A
2011-02-01
Air-flow resistivity is a main parameter governing the acoustic behavior of porous materials for sound absorption. The international standard ISO 9053 specifies two different methods to measure the air-flow resistivity, namely a steady-state air-flow method and an alternating air-flow method. The latter is realized by the measurement of the sound pressure at 2 Hz in a small rigid volume closed partially by the test sample. This cavity is excited with a known volume-velocity sound source implemented often with a motor-driven piston oscillating with prescribed area and displacement magnitude. Measurements at 2 Hz require special instrumentation and care. The authors suggest an alternating air-flow method based on the ratio of sound pressures measured at frequencies higher than 2 Hz inside two cavities coupled through a conventional loudspeaker. The basic method showed that the imaginary part of the sound pressure ratio is useful for the evaluation of the air-flow resistance. Criteria are discussed about the choice of a frequency range suitable to perform simplified calculations with respect to the basic method. These criteria depend on the sample thickness, its nonacoustic parameters, and the measurement apparatus as well. The proposed measurement method was tested successfully with various types of acoustic materials.
Development of an Ultrasonic Airflow Measurement Device for Ducted Air
Raine, Andrew B.; Aslam, Nauman; Underwood, Christopher P.; Danaher, Sean
2015-01-01
In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a “V” shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers. PMID:25954952
Oelsner, Elizabeth C; Carr, J Jeffrey; Enright, Paul L; Hoffman, Eric A; Folsom, Aaron R; Kawut, Steven M; Kronmal, Richard A; Lederer, David J; Lima, Joao A C; Lovasi, Gina S; Smith, Benjamin M; Shea, Steven J; Barr, R Graham
2016-07-01
Emphysema on CT is a risk factor for all-cause mortality in persons with and without airflow obstruction; however, causes of death associated with emphysema remain uncertain, particularly in the general population. To test associations between quantitatively assessed emphysema on CT and cause of death in persons with and without a substantial smoking history. The Multi-Ethnic Study of Atherosclerosis recruited 6814 participants, aged 45-84 years and without clinical cardiovascular disease, in 2000-2002. Per cent emphysema was defined on cardiac CT as per cent of lung voxels less than -950 Hounsfield units; emphysema on CT was defined as per cent emphysema above the upper limit of normal. Cause of death was classified by administrative codes. Proportional-hazards models were adjusted for age, race/ethnicity, gender, body mass index, smoking status, pack-years, coronary artery calcium, site and education. Additional adjustment for lung function was made in a subset with spirometry from 2004 to 2006. There were 1091 deaths over 12 years median follow-up. Emphysema on CT was strongly associated with increased mortality due to respiratory diseases (adjusted HR 2.94, 95% CI 1.68 to 5.15), particularly chronic lower respiratory diseases (adjusted HR 9.54, 95% CI 4.70 to 19.35), and lung cancer (adjusted HR 1.84, 95% CI 1.09 to 3.12), but not cardiovascular disease. Associations persisted among participants with fewer than 10 pack-years and those without physician-diagnosed respiratory disease, and were similar after adjustment for airflow measures and in persons without airflow limitation. Quantitatively assessed emphysema on CT is associated with greater respiratory disease and lung cancer mortality, even among persons without traditional risk factors. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Spits, Christine; Wallace, Luke; Reinke, Karin
2017-01-01
Visual assessment, following guides such as the Overall Fuel Hazard Assessment Guide (OFHAG), is a common approach for assessing the structure and hazard of varying bushfire fuel layers. Visual assessments can be vulnerable to imprecision due to subjectivity between assessors, while emerging techniques such as image-based point clouds can offer land managers potentially more repeatable descriptions of fuel structure. This study compared the variability of estimates of surface and near-surface fuel attributes generated by eight assessment teams using the OFHAG and Fuels3D, a smartphone method utilising image-based point clouds, within three assessment plots in an Australian lowland forest. Surface fuel hazard scores derived from underpinning attributes were also assessed. Overall, this study found considerable variability between teams on most visually assessed variables, resulting in inconsistent hazard scores. Variability was observed within point cloud estimates but was, however, on average two to eight times less than that seen in visual estimates, indicating greater consistency and repeatability of this method. It is proposed that while variability within the Fuels3D method may be overcome through improved methods and equipment, inconsistencies in the OFHAG are likely due to the inherent subjectivity between assessors, which may be more difficult to overcome. This study demonstrates the capability of the Fuels3D method to efficiently and consistently collect data on fuel hazard and structure, and, as such, this method shows potential for use in fire management practices where accurate and reliable data is essential. PMID:28425957
Nguyen, Chinh D.; Wellman, Andrew; Jordan, Amy S.; Eckert, Danny J.
2016-01-01
Study Objectives: To determine the effects of mild airflow limitation on K-complex frequency and morphology and electroencephalogram (EEG) spectral power. Methods: Transient reductions in continuous positive airway pressure (CPAP) during stable N2 sleep were performed to induce mild airflow limitation in 20 patients with obstructive sleep apnea (OSA) and 10 healthy controls aged 44 ± 13 y. EEG at C3 and airflow were measured in 1-min windows to quantify K-complex properties and EEG spectral power immediately before and during transient reductions in CPAP. The frequency and morphology (amplitude and latency of P200, N550 and N900 components) of K-complexes and EEG spectral power were compared between conditions. Results: During mild airflow limitation (18% reduction in peak inspiratory airflow from baseline, 0.38 ± 0.11 versus 0.31 ± 0.1 L/sec) insufficient to cause American Academy of Sleep Medicine-defined cortical arousal, K-complex frequency (9.5 ± 4.5 versus 13.7 ± 6.4 per min, P < 0.01), N550 amplitude (25 ± 3 versus 27 ± 3 μV, P < 0.01) and EEG spectral power (delta: 147 ± 48 versus 230 ± 99 μV2, P < 0.01 and theta bands: 31 ± 14 versus 34 ± 13 μV2, P < 0.01) significantly increased whereas beta band power decreased (14 ± 5 versus 11 ± 4 μV2, P < 0.01) compared to the preceding non flow-limited period on CPAP. K-complex frequency, morphology, and timing did not differ between patients and controls. Conclusion: Mild airflow limitation increases K-complex frequency, N550 amplitude, and spectral power of delta and theta bands. In addition to providing mechanistic insight into the role of mild airflow limitation on K-complex characteristics and EEG activity, these findings may have important implications for respiratory conditions in which airflow limitation during sleep is common (e.g., snoring and OSA). Citation: Nguyen CD, Wellman A, Jordan AS, Eckert DJ. Mild airflow limitation during N2 sleep increases k-complex frequency and slows electroencephalographic activity. SLEEP 2016;39(3):541–550. PMID:26612389
Pitot-tube flowmeter for quantification of airflow during sleep.
Kirkness, J P; Verma, M; McGinley, B M; Erlacher, M; Schwartz, A R; Smith, P L; Wheatley, J R; Patil, S P; Amis, T C; Schneider, H
2011-02-01
The gold-standard pneumotachograph is not routinely used to quantify airflow during overnight polysomnography due to the size, weight, bulkiness and discomfort of the equipment that must be worn. To overcome these deficiencies that have precluded the use of a pneumotachograph in routine sleep studies, our group developed a lightweight, low dead space 'pitot flowmeter' (based on pitot-tube principle) for use during sleep. We aimed to examine the characteristics and validate the flowmeter for quantifying airflow and detecting hypopneas during polysomnography by performing a head-to-head comparison with a pneumotachograph. Four experimental paradigms were utilized to determine the technical performance characteristics and the clinical usefulness of the pitot flowmeter in a head-to-head comparison with a pneumotachograph. In each study (1-4), the pitot flowmeter was connected in series with a pneumotachograph under either static flow (flow generator inline or on a face model) or dynamic flow (subject breathing via a polyester face model or on a nasal mask) conditions. The technical characteristics of the pitot flowmeter showed that, (1) the airflow resistance ranged from 0.065 ± 0.002 to 0.279 ± 0.004 cm H(2)O L(-1) s(-1) over the airflow rates of 10 to 50 L min(-1). (2) On the polyester face model there was a linear relationship between airflow as measured by the pitot flowmeter output voltage and the calibrated pneumotachograph signal a (β(1) = 1.08 V L(-1) s(-1); β(0) = 2.45 V). The clinically relevant performance characteristics (hypopnea detection) showed that (3) when the pitot flowmeter was connected via a mask to the human face model, both the sensitivity and specificity for detecting a 50% decrease in peak-to-peak airflow amplitude was 99.2%. When tested in sleeping human subjects, (4) the pitot flowmeter signal displayed 94.5% sensitivity and 91.5% specificity for the detection of 50% peak-to-peak reductions in pneumotachograph-measured airflow. Our data validate the pitot flowmeter for quantification of airflow and detecting breathing reduction during polysomnographic sleep studies. We speculate that quantifying airflow during sleep can differentiate phenotypic traits related to sleep disordered breathing.
Marków, Magdalena; Janecki, Daniel; Orecka, Bogusława; Misiołek, Maciej; Warmuziński, Krzysztof
2017-09-01
Computational fluid dynamics (CFD), a rapidly developing instrument with a number of practical applications, allows calculation and visualization of the changing parameters of airflow in the upper respiratory tract. The aim of this study was to demonstrate the advantages of CFD as an instrument for noninvasive tests of the larynx in patients who had undergone surgical treatment due to bilateral vocal fold paralysis. Surface measurements of the glottic space were made during maximum adduction of the vocal folds. Additionally, the following spirometric parameters were determined: forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEF) rate. Based on the measurements, commercial mesh generation software was used to develop a geometrical model of the glottic space. The computations were carried out using a general purpose CFD code. The analysis included patients who were surgically treated for BVFP in the authors' department between 1999 and 2012. The study group consisted of 22 women (91.67%) and 2 men (8.33%). It was observed that the pressure drop calculated for free breathing depends on the area of the glottis and is independent of its shape. Importantly, for areas below approx. 40 mm2, a sudden rise occurred in the resistance to flow; for the smallest glottic areas studied, the pressure drop was almost 6 times higher than for an area of 40 mm2. Consequently, in cases of areas below 40 mm2 even minor enlargement of the glottic opening can lead to a marked improvement in breathing comfort. Computational fluid dynamics is a useful method for calculating and visualizing the changing parameters of airflow in the upper respiratory tract.
Separate and combined effects of airflow and rehydration during exercise in the heat.
Mora-Rodriguez, Ricardo; Del Coso, Juan; Aguado-Jimenez, Roberto; Estevez, Emma
2007-10-01
To determine whether airflow is required to obtain the beneficial effects of rehydration (thermoregulatory and cardiovascular) during exercise in dry heat. Ten moderately trained (VO2max = 55 +/- 8 mL.kg(-1).min(-1)) heat acclimated males pedaled for 60 min at 60% VO2max in a hot-dry environment (36 +/- 1 degrees C; 29 +/- 2% relative humidity) on four different occasions: 1) without rehydration or forced airflow (control trial; CON); 2) rehydrating 100% of sweat losses by ingestion of a 6% carbohydrate-electrolyte solution (rehydration trial; REH); 3) receiving airflow at a velocity of 2.55 m.s(-1) (wind trial; WIND); and 4) combining airflow and rehydration (W + R). Without airflow, rehydration alone (REH) did not lower rectal temperature below CON (39.0 +/- 0.1 vs 39.1 +/- 0.1 degrees C at 60 min; respectively). However, with airflow, rehydration reduced final rectal temperature (38.8 +/- 0.1 vs 38.5 +/- 0.1 degrees C; P < 0.05; WIND vs W + R). In the trials with wind (WIND and W + R), skin temperature was reduced by about 0.6 degrees C (P < 0.05), and heart rate drift was prevented. In the trials with rehydration (REH and W + R trials), cardiac output (CO2-rebreathing technique) was maintained higher than CON (16.5 +/- 0.4 and 17.0 +/- 0.7 vs 15.4 +/- 0.4 L.min(-1), respectively; P < 0.05). When exercising in a hot-dry environment, airflow is required for rehydration to improve thermoregulation and cardiovascular function.
Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry
NASA Astrophysics Data System (ADS)
Fojtlín, Miloš; Planka, Michal; Fišer, Jan; Pokorný, Jan; Jícha, Miroslav
2016-03-01
Thermal environment in a vehicular cabin significantly influence drivers' fatigue and passengers' thermal comfort. This environment is traditionally managed by HVAC cabin system that distributes air and modifies its properties. In order to simulate cabin thermal behaviour, amount of the air led through car vents must be determined. The aim of this study was to develop methodology to measure airflow from the vents, and consequently calculate corresponding air distribution coefficients. Three climatic cases were selected to match European winter, summer, and spring / fall conditions. Experiments were conducted on a test vehicle in a climatic chamber. The car HVAC system was set to automatic control mode, and the measurements were executed after the system stabilisation—each case was independently measured three times. To be able to evaluate precision of the method, the airflow was determined at the system inlet (HVAC suction) and outlet (each vent), and the total airflow values were compared. The airflow was calculated by determining a mean value of the air velocity multiplied by an area of inlet / outlet cross-section. Hot-wire anemometry was involved to measure the air velocity. Regarding the summer case, total airflow entering the cabin was around 57 l s-1 with 60 % of the air entering the cabin through dashboard vents; no air was supplied to the feet compartment. The remaining cases had the same total airflow of around 42 l s-1, and the air distribution was focused mainly on feet and windows. The inlet and outlet airflow values show a good match with a maximum mass differential of 8.3 %.
Dynamic wake prediction and visualization with uncertainty analysis
NASA Technical Reports Server (NTRS)
Holforty, Wendy L. (Inventor); Powell, J. David (Inventor)
2005-01-01
A dynamic wake avoidance system utilizes aircraft and atmospheric parameters readily available in flight to model and predict airborne wake vortices in real time. A novel combination of algorithms allows for a relatively simple yet robust wake model to be constructed based on information extracted from a broadcast. The system predicts the location and movement of the wake based on the nominal wake model and correspondingly performs an uncertainty analysis on the wake model to determine a wake hazard zone (no fly zone), which comprises a plurality of wake planes, each moving independently from another. The system selectively adjusts dimensions of each wake plane to minimize spatial and temporal uncertainty, thereby ensuring that the actual wake is within the wake hazard zone. The predicted wake hazard zone is communicated in real time directly to a user via a realistic visual representation. In an example, the wake hazard zone is visualized on a 3-D flight deck display to enable a pilot to visualize or see a neighboring aircraft as well as its wake. The system substantially enhances the pilot's situational awareness and allows for a further safe decrease in spacing, which could alleviate airport and airspace congestion.
Resistance to forced airflow through layers of composting organic material.
Teixeira, Denis Leocádio; de Matos, Antonio Teixeira; Melo, Evandro de Castro
2015-02-01
The objective of this study was to adjust equations to estimate the static pressure gradient of airflow through layers of organic residues submitted to two stages of biochemical degradation, and to evaluate the static pressure drop of airflow thought the material layer. Measurements of static pressure drop in the layers of sugarcane bagasse and coffee husks mixed with poultry litter on day 0 and after 30 days of composting were performed using a prototype with specific airflow rates ranging from 0.02 to 0.13 m(3) s(-1) m(-2). Static pressure gradient and specific airflow rate data were properly fit to the Shedd, Hukill & Ives and Ergun models, which may be used to predict the static pressure gradient of air to be blown through the organic residue layers. However, the Shedd model was that which best represented the phenomenon studied. The static pressure drop of airflow increased as a power of the material layer thickness and showed tendency for decreasing with the biochemical degradation time of the organic material. Copyright © 2014 Elsevier Ltd. All rights reserved.
1979-08-20
A chase plane view of the tufts on the KC-135 winglet. The use of tufts in flight research dates back to the early days of the NACA, and remains an effective means of observing airflow even today. In this procedure, rows of strings are attached to an airplane's surface, with one end of each string taped to the airplane and the other end free to swing about in the airflow. The movements of the tufts are photographed by on-board cameras or a chase plane. If the tufts are arrayed in neat rows, as seen here, then the airflow is smooth over the airplane's surface. If, however, they are moving about violently, it suggests turbulent airflow. Such motions may indicate high drag, flow separation (such as in a stall), or buffeting. In some cases, tufts will actually point forward, indicating the airflow has reversed direction.
Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows.
Schreur, H J; Sterk, P J; Vanderschoot, J; van Klink, H C; van Vollenhoven, E; Dijkman, J H
1992-01-01
BACKGROUND: A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in normal and emphysematous subjects in relation to airflow. METHODS: Eight normal men (45-63 years, FEV1 79-126% predicted) and nine men with severe emphysema (50-70 years, FEV1 14-63% predicted) participated in the study. Emphysema was diagnosed according to pulmonary history, results of lung function tests, and radiographic criteria. All subjects underwent phonopneumography during standardised breathing manoeuvres between 0.5 and 2 1 below total lung capacity with inspiratory and expiratory target airflows of 2 and 1 l/s respectively during 50 seconds. The synchronous measurements included airflow at the mouth and lung volume changes, and lung sounds at four locations on the right chest wall. For each microphone airflow dependent power spectra were computed by using fast Fourier transformation. Lung sound intensity was expressed as log power (in dB) at 200 Hz at inspiratory flow rates of 1 and 2 l/s and at an expiratory flow rate of 1 l/s. RESULTS: Lung sound intensity was well repeatable on two separate days, the intraclass correlation coefficient ranging from 0.77 to 0.94 between the four microphones. The intensity was strongly influenced by microphone location and airflow. There was, however, no significant difference in lung sound intensity at any flow rate between the normal and the emphysema group. CONCLUSION: Airflow standardised lung sound intensity does not differ between normal and emphysematous subjects. This suggests that the auscultatory finding of diminished breath sounds during the regular physical examination in patients with emphysema is due predominantly to airflow limitation. Images PMID:1440459
Nguyen, Chinh D; Wellman, Andrew; Jordan, Amy S; Eckert, Danny J
2016-03-01
To determine the effects of mild airflow limitation on K-complex frequency and morphology and electroencephalogram (EEG) spectral power. Transient reductions in continuous positive airway pressure (CPAP) during stable N2 sleep were performed to induce mild airflow limitation in 20 patients with obstructive sleep apnea (OSA) and 10 healthy controls aged 44 ± 13 y. EEG at C3 and airflow were measured in 1-min windows to quantify K-complex properties and EEG spectral power immediately before and during transient reductions in CPAP. The frequency and morphology (amplitude and latency of P200, N550 and N900 components) of K-complexes and EEG spectral power were compared between conditions. During mild airflow limitation (18% reduction in peak inspiratory airflow from baseline, 0.38 ± 0.11 versus 0.31 ± 0.1 L/sec) insufficient to cause American Academy of Sleep Medicine-defined cortical arousal, K-complex frequency (9.5 ± 4.5 versus 13.7 ± 6.4 per min, P < 0.01), N550 amplitude (25 ± 3 versus 27 ± 3 μV, P < 0.01) and EEG spectral power (delta: 147 ± 48 versus 230 ± 99 μV(2), P < 0.01 and theta bands: 31 ± 14 versus 34 ± 13 μV(2), P < 0.01) significantly increased whereas beta band power decreased (14 ± 5 versus 11 ± 4 μV(2), P < 0.01) compared to the preceding non flow-limited period on CPAP. K-complex frequency, morphology, and timing did not differ between patients and controls. Mild airflow limitation increases K-complex frequency, N550 amplitude, and spectral power of delta and theta bands. In addition to providing mechanistic insight into the role of mild airflow limitation on K-complex characteristics and EEG activity, these findings may have important implications for respiratory conditions in which airflow limitation during sleep is common (e.g., snoring and OSA). © 2016 Associated Professional Sleep Societies, LLC.
Effects of airflow on body temperatures and sleep stages in a warm humid climate
NASA Astrophysics Data System (ADS)
Tsuzuki, Kazuyo; Okamoto-Mizuno, Kazue; Mizuno, Koh; Iwaki, Tatsuya
2008-03-01
Airflow is an effective way to increase heat loss—an ongoing process during sleep and wakefulness in daily life. However, it is unclear whether airflow stimulates cutaneous sensation and disturbs sleep or reduces the heat load and facilitates sleep. In this study, 17 male subjects wearing short pyjamas slept on a bed with a cotton blanket under two of the following conditions: (1) air temperature (Ta) 26°C, relative humidity (RH) 50%, and air velocity (V) 0.2 m s-1; (2) Ta 32°C, RH 80%, V 1.7 m s-1; (3) Ta 32°C; RH 80%, V 0.2 m s-1 (hereafter referred to as 26/50, 32/80 with airflow, and 32/80 with still air, respectively). Electroencephalograms, electrooculograms, and mental electromyograms were obtained for all subjects. Rectal (Tre) and skin (Ts) temperatures were recorded continuously during the sleep session, and body-mass was measured before and after the sleep session. No significant differences were observed in the duration of sleep stages between subjects under the 26/50 and 32/80 with airflow conditions; however, the total duration of wakefulness decreased significantly in subjects under the 32/80 with airflow condition compared to that in subjects under the 32/80 with still air condition ( P < 0.05). Tre, Tsk, Ts, and body-mass loss under the 32/80 with airflow condition were significantly higher compared to those under the 26/50 condition, and significantly lower than those under the 32/80 with still air condition ( P < 0.05). An alleviated heat load due to increased airflow was considered to exist between the 32/80 with still air and the 26/50 conditions. Airflow reduces the duration of wakefulness by decreasing Tre, Tsk, Ts, and body-mass loss in a warm humid condition.
NASA Astrophysics Data System (ADS)
Choi, Sanghun; Choi, Jiwoong; Hoffman, Eric; Lin, Ching-Long
2016-11-01
To predict the proper relationship between airway resistance and regional airflow, we proposed a novel 1-D network model for airway resistance and acinar compliance. First, we extracted 1-D skeletons at inspiration images, and generated 1-D trees of CT unresolved airways with a volume filling method. We used Horsfield order with random heterogeneity to create diameters of the generated 1-D trees. We employed a resistance model that accounts for kinetic energy and viscous dissipation (Model A). The resistance model is further coupled with a regional compliance model estimated from two static images (Model B). For validation, we applied both models to a healthy subject. The results showed that Model A failed to provide airflows consistent with air volume change, whereas Model B provided airflows consistent with air volume change. Since airflows shall be regionally consistent with air volume change in patients with normal airways, Model B was validated. Then, we applied Model B to severe asthmatic subjects. The results showed that regional airflows were significantly deviated from air volume change due to airway narrowing. This implies that airway resistance plays a major role in determining regional airflows of patients with airway narrowing. Support for this study was provided, in part, by NIH Grants U01 HL114494, R01 HL094315, R01 HL112986, and S10 RR022421.
Cheng, Y; Lin, Z
2016-04-01
Room occupants' comfort and health are affected by the airflow. Nevertheless, they themselves also play an important role in indoor air distribution. This study investigated the interaction between the human body and room airflow under stratum ventilation. Simplified thermal manikin was employed to effectively resemble the human body as a flow obstacle and/or free convective heat source. Unheated and heated manikins were designed to fully evaluate the impact of the manikin at various airflow rates. Additionally, subjective human tests were conducted to evaluate thermal comfort for the occupants in two rows. The findings show that the manikin formed a local blockage effect, but the supply airflow could flow over it. With the body heat from the manikin, the air jet penetrated farther compared with that for the unheated manikin. The temperature downstream of the manikin was also higher because of the convective effect. Elevating the supply airflow rate from 7 to 15 air changes per hour varied the downstream airflow pattern dramatically, from an uprising flow induced by body heat to a jet-dominated flow. Subjective assessments indicated that stratum ventilation provided thermal comfort for the occupants in both rows. Therefore, stratum ventilation could be applied in rooms with occupants in multiple rows. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chen, Di; Wu, Junru
2010-01-01
It is known that there are many fine particles on the moon and Mars. Their existence may cause risk for the success of a long-term project for NASA, i.e., exploration and habitation of the moon and Mars. These dust-particles might cover the solar panels, making them fail to generate electricity, and they might also penetrate through seals on space suits, hatches, and vehicle wheels causing many incidents. The fine particles would be hazardous to human health if they were inhaled. Development of robust dust mitigation technology is urgently needed for the viable long-term exploration and habilitation of either the moon or Mars. A feasibility study to develop a dust removal technique, which may be used in space-stations or other enclosures for habitation, is reported. It is shown experimentally that the acoustic radiation force produced by a 13.8 kHz 128 dB sound-level standing wave between a 3 cm-aperture tweeter and a reflector separated by 9 cm is strong enough to overcome the van der Waals adhesive force between the dust-particles and the reflector-surface. Thus the majority of fine particles (>2 microm diameter) on a reflector-surface can be dislodged and removed by a technique combining acoustic levitation and airflow methods. The removal efficiency deteriorates for particles of less than 2 microm in size.
Measurement of Turbine Engine Transient Airflow in Ground Test Facilities
1980-08-01
REPORT NUMBER 12 GOVT ACCESSION NO. A E D C - T R - 8 0 - 2 1 L 6. T I T L E (aqd Subl l l |e ) MEASUREMENT OF TURBINE ENGINE TRANSIENT AIRFLOW IN...21 ILLUSTRATIONS Figure !. Direct-Connect Turbine Engine Test Cell Installation...26 3. Turbine Engine Transient Airflow Simulator (TETAS) . . . . . . . . . . . . . . . . . . . . . . . . . 27 4
Hopkins, Raewyn J; Duan, Fenghai; Chiles, Caroline; Greco, Erin M; Gamble, Greg D; Aberle, Denise; Young, Robert P
2017-03-01
Although epidemiological studies consistently show that chronic obstructive pulmonary disease is associated with an increased risk of lung cancer, debate exists as to whether there is a linear relationship between the severity of airflow limitation and lung cancer risk. We examined this in a large, prospective study of older heavy smokers from the American College of Radiology Imaging Network subcohort of the National Lung Screening Trial (ACRIN). Airflow limitation was defined by prebronchodilator spirometry subgrouped according to Global Initiative for Chronic Obstructive Lung Disease (GOLD) grades 1-4. In the National Lung Screening Trial-ACRIN cohort of 18,473 screening participants, 6,436 had airflow limitation (35%) and 12,037 (65%) had no airflow limitation. From these groups, 758 lung cancer cases were prospectively identified. Participants with airflow limitation were stratified according to GOLD groups 1 (n = 1,607), 2 (n = 3,528), 3 (n = 1,083), and 4 (n = 211). Lung cancer incidence at study end (mean follow-up, 6.4 yr) was compared between the GOLD groups and those with no airflow limitation (referent group). Compared with those with no airflow limitation, where lung cancer incidence was 3.78/1,000 person years, incidence rates increased in a simple linear relationship: GOLD 1 (6.27/1,000 person yr); GOLD 2 (7.86/1,000 person yr); GOLD 3 (10.71/1,000 person yr); and GOLD 4 (13.25/1,000 person yr). All relationships were significant versus the reference group at a P value of 0.0001 or less. In a large prospective study of high-risk cigarette smokers, we report a strong linear relationship between increasing severity of airflow limitation and risk of lung cancer.
Airflow accelerates bovine and human articular cartilage drying and chondrocyte death.
Paterson, S I; Amin, A K; Hall, A C
2015-02-01
Exposure of articular cartilage to static air results in changes to the extracellular matrix (ECM) and stimulates chondrocyte death, which may cause joint degeneration. However during open orthopaedic surgery, cartilage is often exposed to laminar airflow, which may exacerbate these damaging effects. We compared drying in static and moving air in terms of cartilage appearance, hydration and chondrocyte viability, and tested the ability of saline-saturated gauze to limit the detrimental effects of air exposure. Articular cartilage from bovine metatarsophalangeal joints (N = 50) and human femoral heads (N = 6) was exposed for 90 min to (1) static air (2) airflow (up to 0.34 m/s), or (3) airflow (0.18 m/s), covered with gauze. Following air exposure, cartilage was also rehydrated (0.9% saline; 120 min) to determine the reversibility of drying effects. The influence of airflow was assessed by studying macroscopic appearance, and quantifying superficial zone (SZ) chondrocyte viability and cartilage hydration. Airflow caused advanced changes to cartilage appearance, accelerated chondrocyte death, and increased dehydration compared to static air. These effects were prevented if cartilage was covered by saline-saturated gauze. Cartilage rehydration reversed macroscopic changes associated with drying but the chondrocyte death was not altered. Chondrocytes at the cut edge of cartilage were more sensitive to drying compared to cells distant from the edge. Airflow significantly increased articular cartilage dehydration and chondrocyte death compared to static air. As laminar airflow is routinely utilised in operating theatres, it is essential that articular cartilage is kept wet via irrigation or by covering with saline-saturated gauze to prevent chondrocyte death. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
KC-135A in flight - closeup of winglet with attached tufts
NASA Technical Reports Server (NTRS)
1979-01-01
A chase plane view of the tufts on the KC-135 winglet. The use of tufts in flight research dates back to the early days of the NACA, and remains an effective means of observing airflow even today. In this procedure, rows of strings are attached to an airplane's surface, with one end of each string taped to the airplane and the other end free to swing about in the airflow. The movements of the tufts are photographed by on-board cameras or a chase plane. If the tufts are arrayed in neat rows, as seen here, then the airflow is smooth over the airplane's surface. If, however, they are moving about violently, it suggests turbulent airflow. Such motions may indicate high drag, flow separation (such as in a stall), or buffeting. In some cases, tufts will actually point forward, indicating the airflow has reversed direction.
NASA Astrophysics Data System (ADS)
Noor, N. A. W. Mohd; Hassan, H.; Hashim, M. F.; Hasini, H.; Munisamy, K. M.
2017-04-01
This paper presents an investigation on the effects of primary airflow to coal fineness in coal-fired boilers. In coal fired power plant, coal is pulverized in a pulverizer, and it is then transferred to boiler for combustion. Coal need to be ground to its desired size to obtain maximum combustion efficiency. Coarse coal particle size may lead to many performance problems such as formation of clinker. In this study, the effects of primary airflow to coal particles size and coal flow distribution were investigated by using isokinetic coal sampling and computational fluid dynamic (CFD) modelling. Four different primary airflows were tested and the effects to resulting coal fineness were recorded. Results show that the optimum coal fineness distribution is obtained at design primary airflow. Any reduction or increase of air flow rate results in undesirable coal fineness distribution.
Wind conditions in urban layout - Numerical and experimental research
NASA Astrophysics Data System (ADS)
Poćwierz, Marta; Zielonko-Jung, Katarzyna
2018-01-01
This paper presents research which compares the numerical and the experimental results for different cases of airflow around a few urban layouts. The study is concerned mostly with the analysis of parameters, such as pressure and velocity fields, which are essential in the building industry. Numerical simulations have been performed by the commercial software Fluent, with the use of a few different turbulence models, including popular k-ɛ, k-ɛ realizable or k-ω. A particular attention has been paid to accurate description of the conditions on the inlet and the selection of suitable computing grid. The pressure measurement near buildings and oil visualization were undertaken and described accordingly.
NASA Technical Reports Server (NTRS)
Shaw, R. J.; Mitchell, G. A.; Sanders, B. W.
1974-01-01
The results of an experimental investigation to increase the stable airflow operating range of a supersonic, mixed-compression inlet with 60-percent internal contraction are presented. Various distributed-porous, throat stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 25 percent was obtained with the optimum configuration if a constant pressure was maintained in the by-pass plenum. The location of the centerbody bleed region had a decided effect on the overall inlet performance. Limited unstart angle-of-attack data are presented.
Using Computational Fluid Dynamics to examine airflow characteristics in Empty Nose Syndrome
NASA Astrophysics Data System (ADS)
Flint, Tim; Esmaily-Moghadam, Mahdi; Thamboo, Andrew; Velasquez, Nathalia; Nayak, Jayakar V.; Sellier, Mathieu; Moin, Parviz
2016-11-01
The enigmatic disorder, empty nose syndrome (ENS), presents with a complex subjective symptom profile despite objectively patent nasal airways, and recent reports suggest that surgical augmentation of the nasal airway can improve quality of life and ENS-related complaints. In this study, computational fluid dynamics (CFD) was performed both prior to, and following, inferior turbinate augmentation to model the resultant changes in airflow patterns and better understand the pathophysiology of ENS. An ENS patient with marked reduction in ENS symptoms following turbinate augmentation was identified, and pre- and post-operative CT imaging was collected. A Finite element framework with the variational multiscale method (Esmaily-Moghadam, Comput. Methods Appl. Mech. Engrg. 2015) was used to compute the airflow, temperature, and moisture transport through the nasal cavity. Comparison of the CFD results following corrective surgery showed higher levels of airflow turbulence. Augmentation produced 50%, 25%, and 25% increases in root mean square pressure, wall shear stress, and heat flux respectively. These results provide insight into the changes in nasal airflow characteristics attainable through surgical augmentation, and by extension, how nasal airflow patterns may be distorted in the 'overly patent' airway of ENS patients. Supported by Stanford University CTR and Fulbright New Zealand.
Assessing natural hazard risk using images and data
NASA Astrophysics Data System (ADS)
Mccullough, H. L.; Dunbar, P. K.; Varner, J. D.; Mungov, G.
2012-12-01
Photographs and other visual media provide valuable pre- and post-event data for natural hazard assessment. Scientific research, mitigation, and forecasting rely on visual data for risk analysis, inundation mapping and historic records. Instrumental data only reveal a portion of the whole story; photographs explicitly illustrate the physical and societal impacts from the event. Visual data is rapidly increasing as the availability of portable high resolution cameras and video recorders becomes more attainable. Incorporating these data into archives ensures a more complete historical account of events. Integrating natural hazards data, such as tsunami, earthquake and volcanic eruption events, socio-economic information, and tsunami deposits and runups along with images and photographs enhances event comprehension. Global historic databases at NOAA's National Geophysical Data Center (NGDC) consolidate these data, providing the user with easy access to a network of information. NGDC's Natural Hazards Image Database (ngdc.noaa.gov/hazardimages) was recently improved to provide a more efficient and dynamic user interface. It uses the Google Maps API and Keyhole Markup Language (KML) to provide geographic context to the images and events. Descriptive tags, or keywords, have been applied to each image, enabling easier navigation and discovery. In addition, the Natural Hazards Map Viewer (maps.ngdc.noaa.gov/viewers/hazards) provides the ability to search and browse data layers on a Mercator-projection globe with a variety of map backgrounds. This combination of features creates a simple and effective way to enhance our understanding of hazard events and risks using imagery.
Högner, N
2015-08-01
Blind and visually impaired people experience special risks and hazards in road traffic. This refers to participation as a driver, bicycle rider and pedestrian. These risks are shown by a review of international research studies and a study by the author, where 45 people with Usher syndrome were asked about their accident rates and causes as driver, bicycle rider and pedestrian. In addition, basic legal information has been worked out to demonstrate the visual conditions of people with visual impairment for participation in road traffic. The research studies show that blind and visually impaired persons are particularly exposed to experience high risks in traffic. These risks can be reduced through acquisition of skills and coping strategies such as training in orientation and mobility. People with visual impairment need special programmes which help to reduce traffic hazards. Georg Thieme Verlag KG Stuttgart · New York.
Roche, Nicolas; Dalmay, François; Perez, Thierry; Kuntz, Claude; Vergnenègre, Alain; Neukirch, Françoise; Giordanella, Jean-Pierre; Huchon, Gérard
2008-11-01
Little is known on the long-term validity of reference equations used in the calculation of FEV(1) and FEV(1)/FVC predicted values. This survey assessed the prevalence of chronic airflow obstruction in a population-based sample and how it is influenced by: (i) the definition of airflow obstruction; and (ii) equations used to calculate predicted values. Subjects aged 45 or more were recruited in health prevention centers, performed spirometry and fulfilled a standardized ECRHS-derived questionnaire. Previously diagnosed cases and risk factors were identified. Prevalence of airflow obstruction was calculated using: (i) ATS-GOLD definition (FEV(1)/FVC<0.70); and (ii) ERS definition (FEV(1)/FVC
Hardin, Megan E.; Come, Carolyn E.; San José Estépar, Raúl; Ross, James C.; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K.; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K.; Crapo, James D.; Lynch, David A.; Make, Barry; Barr, R. Graham; Hersh, Craig P.; Washko, George R.
2014-01-01
Rationale and Objectives: Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. Methods: We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Measurements and Main Results: Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. Conclusion: In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764). PMID:25296268
Corley, R A; Minard, K R; Kabilan, S; Einstein, D R; Kuprat, A P; Harkema, J R; Kimbell, J S; Gargas, M L; Kinzell, John H
2009-05-01
The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation. These airflow calculations, along with nasal airway geometry determinations, are critical parameters for hybrid CFD/physiologically based pharmacokinetic models that describe the nasal dosimetry of water-soluble or reactive gases and vapors in rabbits. CFD simulations were based upon three-dimensional computational meshes derived from magnetic resonance images of three adult female New Zealand White (NZW) rabbits. In the anterior portion of the nose, the maxillary turbinates of rabbits are considerably more complex than comparable regions in rats, mice, monkeys, or humans. This leads to a greater surface area to volume ratio in this region and thus the potential for increased extraction of water soluble or reactive gases and vapors in the anterior portion of the nose compared to many other species. Although there was considerable interanimal variability in the fine structures of the nasal turbinates and airflows in the anterior portions of the nose, there was remarkable consistency between rabbits in the percentage of total inspired airflows that reached the ethmoid turbinate region (approximately 50%) that is presumably lined with olfactory epithelium. These latter results (airflows reaching the ethmoid turbinate region) were higher than previous published estimates for the male F344 rat (19%) and human (7%). These differences in regional airflows can have significant implications in interspecies extrapolations of nasal dosimetry.
Diaz, Alejandro A; Hardin, Megan E; Come, Carolyn E; San José Estépar, Raúl; Ross, James C; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K; Crapo, James D; Lynch, David A; Make, Barry; Barr, R Graham; Hersh, Craig P; Washko, George R
2014-11-01
Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).
Mockup Small-Diameter Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke and A. Rudd
2016-05-01
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
Analysis of Clinicians' Perceptual Cough Evaluation.
Laciuga, Helena; Brandimore, Alexandra E; Troche, Michelle S; Hegland, Karen W
2016-08-01
This study examined the relationships between subjective descriptors and objective airflow measures of cough. We hypothesized that coughs with specific airflow characteristics would share common subjective perceptual descriptions. Thirty clinicians (speech-language pathologists, otolaryngologists, and neurologists) perceptually evaluated ten cough audio samples with specific airflow characteristics determined by peak expiratory flow rate, cough expired volume, cough duration, and number of coughs in the cough epoch. Participants rated coughs by strength, duration, quality, quantity, and overall potential effectiveness for airway protection. Perception of cough strength and effectiveness was determined by the combination of presence of pre-expulsive compression phase, short peak expiratory airflow rate rise time, high peak expiratory flow rates, and high cough volume acceleration. Perception of cough abnormality was defined predominantly by descriptors of breathiness and strain. Breathiness was characteristic for coughs with either absent compression phases and relatively high expiratory airflow rates or coughs with significantly low expired volumes and reduced peak flow rates. In contrast, excessive strain was associated with prolonged compression phases and low expiratory airflow rates or the absence of compression phase with high peak expiratory rates. The study participants reached greatest agreement in distinguishing between single and multiple coughs. Their assessment of cough strength and effectiveness was less consistent. Finally, the least agreement was shown in determining the quality categories. Modifications of cough airflow can influence perceptual cough evaluation outcomes. However, the inconsistency of cough ratings among our participants suggests that a uniform cough rating system is required.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
NASA Astrophysics Data System (ADS)
Garcia, Guilherme; Sullivan, Corbin; Frank-Ito, Dennis; Kimbell, Julia; Rhee, John
2014-11-01
Nasal airway obstruction (NAO) is a common health problem with 340,000 patients undergoing surgery annually in the United States. Traditionally, otolaryngologists have focused on airspace cross-sectional areas and nasal resistance to airflow as objective measures of nasal patency, but neither of these variables correlated consistently with patients' symptoms. Given that the sensation of nasal airflow is also associated with mucosal cooling (i.e., heat loss) during inspiration, we investigated the correlation between the sensation of nasal obstruction and mucosal cooling in 10 patients before and after NAO surgery. Three-dimensional models of the nasal anatomy were created based on pre- and post-surgery computed tomography scans. Computational fluid dynamics (CFD) simulations were conducted to quantify nasal resistance and mucosal cooling. Patient-reported symptoms were measured by a visual analog scale and the Nasal Obstruction Symptom Evaluation (NOSE), a disease-specific quality of life questionnaire. Our results revealed that the subjective sensation of nasal obstruction correlated with both nasal resistance and heat loss, but the strongest correlation was between the NOSE score and the nasal surface area where heat flux exceeds 50 W /m2 . In conclusion, a significant post-operative increase in mucosal cooling correlates well with patients' perception of better nasal patency after NAO surgery.
Airflow analyses using thermal imaging in Arizona's Meteor Crater as part of METCRAX II
NASA Astrophysics Data System (ADS)
Grudzielanek, A. Martina; Vogt, Roland; Cermak, Jan; Maric, Mateja; Feigenwinter, Iris; Whiteman, C. David; Lehner, Manuela; Hoch, Sebastian W.; Krauß, Matthias G.; Bernhofer, Christian; Pitacco, Andrea
2016-04-01
In October 2013 the second Meteor Crater Experiment (METCRAX II) took place at the Barringer Meteorite Crater (aka Meteor Crater) in north central Arizona, USA. Downslope-windstorm-type flows (DWF), the main research objective of METCRAX II, were measured by a comprehensive set of meteorological sensors deployed in and around the crater. During two weeks of METCRAX II five infrared (IR) time lapse cameras (VarioCAM® hr research & VarioCAM® High Definition, InfraTec) were installed at various locations on the crater rim to record high-resolution images of the surface temperatures within the crater from different viewpoints. Changes of surface temperature are indicative of air temperature changes induced by flow dynamics inside the crater, including the DWF. By correlating thermal IR surface temperature data with meteorological sensor data during intensive observational periods the applicability of the IR method of representing flow dynamics can be assessed. We present evaluation results and draw conclusions relative to the application of this method for observing air flow dynamics in the crater. In addition we show the potential of the IR method for METCRAX II in 1) visualizing airflow processes to improve understanding of these flows, and 2) analyzing cold-air flows and cold-air pooling.
Lidar and Electro-Optics for Atmospheric Hazard Sensing and Mitigation
NASA Technical Reports Server (NTRS)
Clark, Ivan O.
2012-01-01
This paper provides an overview of the research and development efforts of the Lidar and Electro-Optics element of NASA's Aviation Safety Program. This element is seeking to improve the understanding of the atmospheric environments encountered by aviation and to provide enhanced situation awareness for atmospheric hazards. The improved understanding of atmospheric conditions is specifically to develop sensor signatures for atmospheric hazards. The current emphasis is on kinetic air hazards such as turbulence, aircraft wake vortices, mountain rotors, and windshear. Additional efforts are underway to identify and quantify the hazards arising from multi-phase atmospheric conditions including liquid and solid hydrometeors and volcanic ash. When the multi-phase conditions act as obscurants that result in reduced visual awareness, the element seeks to mitigate the hazards associated with these diminished visual environments. The overall purpose of these efforts is to enable safety improvements for air transport class and business jet class aircraft as the transition to the Next Generation Air Transportation System occurs.
Occupant-responsive optimal control of smart facade systems
NASA Astrophysics Data System (ADS)
Park, Cheol-Soo
Windows provide occupants with daylight, direct sunlight, visual contact with the outside and a feeling of openness. Windows enable the use of daylighting and offer occupants a outside view. Glazing may also cause a number of problems: undesired heat gain/loss in winter. An over-lit window can cause glare, which is another major complaint by occupants. Furthermore, cold or hot window surfaces induce asymmetric thermal radiation which can result in thermal discomfort. To reduce the potential problems of window systems, double skin facades and airflow window systems have been introduced in the 1970s. They typically contain interstitial louvers and ventilation openings. The current problem with double skin facades and airflow windows is that their operation requires adequate dynamic control to reach their expected performance. Many studies have recognized that only an optimal control enables these systems to truly act as active energy savers and indoor environment controllers. However, an adequate solution for this dynamic optimization problem has thus far not been developed. The primary objective of this study is to develop occupant responsive optimal control of smart facade systems. The control could be implemented as a smart controller that operates the motorized Venetian blind system and the opening ratio of ventilation openings. The objective of the control is to combine the benefits of large windows with low energy demands for heating and cooling, while keeping visual well-being and thermal comfort at an optimal level. The control uses a simulation model with an embedded optimization routine that allows occupant interaction via the Web. An occupant can access the smart controller from a standard browser and choose a pre-defined mode (energy saving mode, visual comfort mode, thermal comfort mode, default mode, nighttime mode) or set a preferred mode (user-override mode) by moving preference sliders on the screen. The most prominent feature of these systems is the capability of dynamically reacting to the environmental input data through real-time optimization. The proposed occupant responsive optimal control of smart facade systems could provide a breakthrough in this under-developed area and lead to a renewed interest in smart facade systems.
Deep Learning for Discovery of Atmospheric Mountain Waves in MODIS and GPS Data
NASA Astrophysics Data System (ADS)
Pankratius, V.; Li, J. D.; Rude, C. M.; Gowanlock, M.; Herring, T.
2017-12-01
Airflow over mountains can produce gravity waves, called lee waves, which can generate atmospheric turbulence. Since this turbulence poses dangers to aviation, it is critical to identify such regions reliably in an automated fashion. This work leverages two sources of data to go beyond an ad-hoc human visual approach for such identification: MODIS imagery containing cloud patterns formed by lee waves, and patterns in GPS signals resulting from the transmission through atmospheric turbulence due to lee waves. We demonstrate a novel machine learning approach that fuses these two data types to detect atmospheric turbulence associated with lee waves. A convolutional neural network is trained on MODIS tile images to automatically classify the lee wave cloud patterns with 96% correct classifications on a validation set of 20,000 MODIS 64x64 tiles over a test region in the Sierra Nevada Mountains. Signals from GPS stations of the Plate Boundary Observatory are used for feature extraction related to lee waves, in order to improve the confidence of a detection in the MODIS imagery at a given position. To our knowledge, this is the first technique to combine these images and time series data types to improve the spatial and temporal resolutions for large-scale measurements of lee wave formations. First results of this work show great potential for improving weather condition monitoring, hazard and cloud pattern detection, as well as GPS navigation uncertainties. We acknowledge support from NASA AISTNNX15AG84G (PI Pankratius), NASA NNX14AQ03G (PI Herring), and NSF ACI1442997 (PI Pankratius).
Comparison of Methane Control Methods in Polish and Vietnamese Coal Mines
NASA Astrophysics Data System (ADS)
Borowski, Marek; Kuczera, Zbigniew
2018-03-01
Methane hazard often occurs in hard coal mines and causes very serious accidents and can be the reason of methane or methane and coal dust explosions. History of coal mining shows that methane released from the rock mass to the longwall area was responsible for numerous mining disasters. The main source of methane are coal deposits because it is autochthonous gas and is closely related with carbonification and forming of coal deposits. Degree of methane saturation in coal deposits depends on numerous factors; mainly on presence or lack of insulating layers in cover deposit that allow or do not on degasification and easily methane outflow into surroundings. Hence in coal mining there are coal deposits that contain only low degree of methane saturation in places where is lack of insulating layers till high in methane coal deposits occurring in insulating claystones or in shales. Conducting mining works in coal deposits of high methane hazard without using of special measures to combat (ventilation, methane drainage) could be impossible. Control of methane hazard depends also on other co-occuring natural dangers for which used preventive actions eliminate methane hazard. Safety in mines excavating coal deposits saturated with methane depends on the correct estimation of methane hazard, drawn up forecasts, conducted observations, hazard control as well as undertaken prevention measures. Methane risk prevention includes identification and control methods of methane hazards as well as means of combating the explosive accumulation of methane in longwall workings. The main preventive actions in underground coal mines are: effective ventilation that prevents forming of methane fuses or placed methane accumulation in headings ventilated by airflow created by main fans and in headings with auxiliary ventilation, methane drainage using drain holes that are drilled from underground headings or from the surface, methanometry control of methane concentration in the air; location of the sensors is defined by law, additional ventilation equipment used in places of lower intensity of ventilation and places where methane is concentrated.
Çolak, Yunus; Afzal, Shoaib; Nordestgaard, Børge G; Lange, Peter
2016-07-01
A substantial proportion of individuals with airflow limitation are never-smokers. However, whether never-smokers with airflow limitation have undiagnosed asthma is unknown. We hypothesised that the majority of never-smokers with respiratory symptoms and airflow limitation but without known asthma have undiagnosed asthma by comparing characteristics and prognosis in never-smokers with airflow limitation and asthma (NS+AFL+A) with never-smokers with airflow limitation but without asthma (NS+AFL-A). Among 94 079 participants aged 20-100 years from the general population, 39 102 (42%) were never-smokers. In this group, 13 719 (35%) reported to have respiratory symptoms of whom 1610 (12%) had airflow limitation. We investigated characteristics and risk of complications (asthma or COPD exacerbations, pneumonias and all-cause mortality) and comorbidities (lung cancer, ischaemic heart disease, myocardial infarction, deep venous thrombosis and PE) during 4.5 years median follow-up. NS+AFL-A compared with NS+AFL+A reported less allergy and respiratory symptoms, and had higher FEV1 and lower levels of eosinophils and IgE in peripheral blood. NS+AFL+A had increased risk of asthma and COPD exacerbations, but not of pneumonias; adjusted HRs in NS+AFL+A compared with NS+AFL-A were 16 (95% CI 3.7 to 73) for asthma exacerbations and 15 (2.8 to 80) for COPD exacerbations. Still, NS+AFL-A had increased risk of COPD exacerbations and pneumonias, but not of asthma exacerbations; adjusted HRs in NS+AFL-A compared with never-smokers without airflow limitation or asthma (NS-AFL-A) were 7.7 (2.8 to 21) for COPD exacerbations and 1.7 (1.3 to 2.3) for pneumonias. Risk of comorbidities or all-cause mortality was not increased in NS+AFL-A or NS+AFL+A compared with NS-AFL-A. Majority of NS+AFL-A do not seem to have undiagnosed asthma and may instead have airflow limitation caused by other risk factors. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Chen, Xiaole; Lin, Jiang
2017-01-01
Determining the impact of inter-subject variability on airflow pattern and nanoparticle deposition in the human respiratory system is necessary to generate population-representative models, useful for several biomedical engineering applications. Thus, the overall research objective is to quantitatively correlate geometric parameters and coupled transport characteristics of air, vapor, and nanoparticles. Focusing on identifying morphological parameters that significantly influence airflow field and nanoparticle transport, an experimentally validated computational fluid-particle dynamics (CFPD) model was employed to simulate airflow pattern in three human lung-airway configurations. The numerical results will be used to generate guidelines to construct a representative geometry of the human respiratory system. PMID:29144436
Inlet-engine matching for SCAR including application of a bicone variable geometry inlet
NASA Technical Reports Server (NTRS)
Wasserbauer, J. F.; Gerstenmaier, W. H.
1978-01-01
Airflow characteristics of variable cycle engines (VCE) designed for Mach 2.32 can have transonic airflow requirements as high as 1.6 times the cruise airflow. This is a formidable requirement for conventional, high performance, axisymmetric, translating centerbody mixed compression inlets. An alternate inlet is defined, where the second cone of a two cone center body collapses to the initial cone angle to provide a large off-design airflow capability, and incorporates modest centerbody translation to minimize spillage drag. Estimates of transonic spillage drag are competitive with those of conventional translating centerbody inlets. The inlet's cruise performance exhibits very low bleed requirements with good recovery and high angle of attack capability.
Li, Guang; Huang, Hailiang; Chen, Qing; Gaebler, Carl P.; Lin, Tiffany; Yuan, Amy; Rimner, Andreas; Mechalakos, James
2016-01-01
Purpose: To provide a comprehensive characterization of a novel respiratory surrogate that uses optical surface imaging (OSI) for accurate tidal volume (TV) measurement, dynamic airflow (TV′) calculation, and quantitative breathing pattern (BP) estimation during free breathing (FB), belly breathing (BB), chest breathing (CB), and breath hold (BH). Methods: Optical surface imaging, which captures all respiration-induced torso surface motion, was applied to measure respiratory TV, TV′, and BP in three common breathing patterns. Eleven healthy volunteers participated in breathing experiments with concurrent OSI-based and conventional spirometric measurements under an institutional review board approved protocol. This OSI-based technique measures dynamic TV from torso volume change (ΔVtorso = TV) in reference to full exhalation and airflow (TV′ = dTV/dt). Volume conservation, excluding exchanging air, was applied for OSI-based measurements under negligible pleural pressure variation in FB, BB, and CB. To demonstrate volume conservation, a constant TV was measured during BH while the chest and belly are moving (“pretended” respiration). To assess the accuracy of OSI-based spirometry, a conventional spirometer was used as the standard for both TV and TV′. Using OSI, BP was measured as BPOSI = ΔVchest/ΔVtorso and BP can be visualized using BPSHI = SHIchest/(SHIchest + SHIbelly), where surface height index (SHI) is defined as the mean vertical distance within a region of interest on the torso surface. A software tool was developed for OSI image processing, volume calculation, and BP visualization, and another tool was implemented for data acquisition using a Bernoulli-type spirometer. Results: The accuracy of the OSI-based spirometry is −21 ± 33 cm3 or −3.5% ± 6.3% averaged from 11 volunteers with 76 ± 28 breathing cycles on average in FB. Breathing variations between two separate acquisitions with approximate 30-min intervals are substantial: −1% ± 34% (ranging from −64% to 40%) in TV, 4% ± 20% (ranging from −50% to 26%) in breathing period (T), and −1% ± 34% (ranging from −49% to 44%) in BP. The airflow accuracy and variation (between two exercises) are −1 ± 54 cm3/s and −5% ± 30%, respectively. The slope of linear regression between OSI–TV and spirometric TV is 0.93 (R2 = 0.95) for FB, 0.96 (R2 = 0.98) for BB, and 0.95 (R2 = 0.95) for CB. The correlation between the two spirometric measurements is 0.98 ± 0.01. BP increases from BB, FB to CB, while TV increases from FB, BB, to CB. Under BH, 4% volume variation (range) on average was observed. Conclusions: The OSI-based technique provides an accurate measurement of tidal volume, airflow rate, and breathing pattern; all affect internal organ motion. This technique can be applied to various breathing patterns, including FB, BB, and CB. Substantial breathing irregularities and irreproducibility were observed and quantified with the OSI-based technique. These breathing parameters are useful to quantify breathing conditions, which could be used for effective tumor motion predictions. PMID:26936719
Application of zonal model on indoor air sensor network design
NASA Astrophysics Data System (ADS)
Chen, Y. Lisa; Wen, Jin
2007-04-01
Growing concerns over the safety of the indoor environment have made the use of sensors ubiquitous. Sensors that detect chemical and biological warfare agents can offer early warning of dangerous contaminants. However, current sensor system design is more informed by intuition and experience rather by systematic design. To develop a sensor system design methodology, a proper indoor airflow modeling approach is needed. Various indoor airflow modeling techniques, from complicated computational fluid dynamics approaches to simplified multi-zone approaches, exist in the literature. In this study, the effects of two airflow modeling techniques, multi-zone modeling technique and zonal modeling technique, on indoor air protection sensor system design are discussed. Common building attack scenarios, using a typical CBW agent, are simulated. Both multi-zone and zonal models are used to predict airflows and contaminant dispersion. Genetic Algorithm is then applied to optimize the sensor location and quantity. Differences in the sensor system design resulting from the two airflow models are discussed for a typical office environment and a large hall environment.
Airflow energy harvesting with high wind velocities for industrial applications
NASA Astrophysics Data System (ADS)
Chew, Z. J.; Tuddenham, S. B.; Zhu, M.
2016-11-01
An airflow energy harvester capable of harvesting energy from vortices at high speed is presented in this paper. The airflow energy harvester is implemented using a modified helical Savonius turbine and an electromagnetic generator. A power management module with maximum power point finding capability is used to manage the harvested energy and convert the low voltage magnitude from the generator to a usable level for wireless sensors. The airflow energy harvester is characterized using vortex generated by air hitting a plate in a wind tunnel. By using an aircraft environment with wind speed of 17 m/s as case study, the output power of the airflow energy harvester is measured to be 126 mW. The overall efficiency of the power management module is 45.76 to 61.2%, with maximum power point tracking efficiency of 94.21 to 99.72% for wind speed of 10 to 18 m/s, and has a quiescent current of 790 nA for the maximum power point tracking circuit.
Rao, A J; Niwa, H; Watanabe, Y; Fukuta, S; Yanagita, N
1990-05-01
Cannula occlusion is a life-threatening postoperative complication of tracheostomy. Current management largely relies on nursing care for prevention of fatalities because no proven mechanical, machine-based support monitoring exists. The objective of this paper was to address the problem of monitoring the state of cannula patency, based on analysis of airflow acoustic spectral patterns in tracheostomized adult patients in the patent and partially occluded cannula. Tracheal airflow sounds were picked up via a condenser microphone air-coupled to the skin just below the tracheal stoma. Signal output from Mic was amplified, high-pass filtered, digital tape-recorded, and analyzed on a mainframe computer. Although airflow frequencies for patient cannulae were predominantly low-pitched (0.1 to 0.3 kHz), occluded tubes had discrete high-pitched spectral peaks (1.3 to 1.6 kHz). These results suggest that frequency analysis of airflow sounds can identify a change in the status of cannula patency.
Thermal sensation and comfort during exposure to local airflow to face or legs.
Yamashita, Kazuaki; Matsuo, Juntaro; Tochihara, Yutaka; Kondo, Youichiro; Takayama, Shizuka; Nagayama, Hiroki
2005-01-01
The present study examined the contribution of local airflow temperature to thermal sensation and comfort in humans. Eight healthy male students were exposed to local airflow to their faces (summer condition) or legs (winter condition) for 30 minutes. Local airflow temperature (Tf) was maintained at 18 degrees C to 36 degrees C, and ambient temperature (Ta) was maintained at 17.4 degrees C to 31.4 degrees C. Each subject was exposed to 16 conditions chosen from the combination of Tf and Ta. Based on the results of multiple regression analysis, the standardized partial regression coefficient of Tf and Ta were determined to be 0.93 and 0.13 in the summer condition, and 0.71 and 0.36 in the winter condition at the end of the exposure. Also, thermal comfort was observed to depend closely on the interrelation between Tf and Ta. The present data suggested that local airflow temperature is an important thermal factor regarding thermal sensation and comfort.
Engine flow visualization using a copper vapor laser
NASA Technical Reports Server (NTRS)
Regan, Carolyn A.; Chun, Kue S.; Schock, Harold J., Jr.
1987-01-01
A flow visualization system has been developed to determine the air flow within the combustion chamber of a motored, axisymmetric engine. The engine has been equipped with a transparent quartz cylinder, allowing complete optical access to the chamber. A 40-Watt copper vapor laser is used as the light source. Its beam is focused down to a sheet approximately 1 mm thick. The light plane is passed through the combustion chamber, and illuminates oil particles which were entrained in the intake air. The light scattered off of the particles is recorded by a high speed rotating prism movie camera. A movie is then made showing the air flow within the combustion chamber for an entire four-stroke engine cycle. The system is synchronized so that a pulse generated by the camera triggers the laser's thyratron. The camera is run at 5,000 frames per second; the trigger drives one laser pulse per frame. This paper describes the optics used in the flow visualization system, the synchronization circuit, and presents results obtained from the movie. This is believed to be the first published study showing a planar observation of airflow in a four-stroke piston-cylinder assembly. These flow visualization results have been used to interpret flow velocity measurements previously obtained with a laser Doppler velocimetry system.
2013-10-07
from the SAGAT and designed to assess the perception and comprehension components of SA. Asking questions of the par- ticipant after each trial...hazards were no closer than 3° of visual angle from each other. This design ensured that targets and hazards could not co- occur in the same...vehicle triggered the payload task, whereby the operator performed a visual search task to identify an object, such as a ship or a car , in the payload
Detecting Traversable Area and Water Hazards for the Visually Impaired with a pRGB-D Sensor
Yang, Kailun; Wang, Kaiwei; Cheng, Ruiqi; Hu, Weijian; Huang, Xiao; Bai, Jian
2017-01-01
The use of RGB-Depth (RGB-D) sensors for assisting visually impaired people (VIP) has been widely reported as they offer portability, function-diversity and cost-effectiveness. However, polarization cues to assist traversability awareness without precautions against stepping into water areas are weak. In this paper, a polarized RGB-Depth (pRGB-D) framework is proposed to detect traversable area and water hazards simultaneously with polarization-color-depth-attitude information to enhance safety during navigation. The approach has been tested on a pRGB-D dataset, which is built for tuning parameters and evaluating the performance. Moreover, the approach has been integrated into a wearable prototype which generates a stereo sound feedback to guide visually impaired people (VIP) follow the prioritized direction to avoid obstacles and water hazards. Furthermore, a preliminary study with ten blindfolded participants suggests its effectivity and reliability. PMID:28817069
Tuthill, Richard S; Davis, Dustin W; Dai, Zhongtao
2015-02-03
A disclosed fuel injector provides mixing of fuel with airflow by surrounding a swirled fuel flow with first and second swirled airflows that ensures mixing prior to or upon entering the combustion chamber. Fuel tubes produce a central fuel flow along with a central airflow through a plurality of openings to generate the high velocity fuel/air mixture along the axis of the fuel injector in addition to the swirled fuel/air mixture.
Computer simulation of airflow through a multi-generation tracheobronchial conducting airway
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fan, B.; Cheng, Yung-Sung; Yeh, Hsu-Chi
1995-12-01
Knowledge of airflow patterns in the human lung is important for an analysis of lung diseases and drug delivery of aerosolized medicine for medical treatment. However, very little systematic information is available on the pattern of airflow in the lung and on how this pattern affects the deposition of toxicants in the lung, and the efficacy of aerosol drug therapy. Most previous studies have only considered the airflow through a single bifurcating airway. However, the flow in a network of more than one bifurcation is more complicated due to the effect of interrelated lung generations. Because of the variation ofmore » airway geometry and flow condition from generation to generation, a single bifurcating airway cannot be taken as a representative for the others in different generations. The flow in the network varies significantly with airway generations because of a redistribution of axial momentum by the secondary flow motions. The influence of the redistribution of flow is expected in every generation. Therefore, a systematic information of the airflow through a multi-generation tracheobronchial conducting airway is needed, and it becomes the purpose of this study. This study has provided information on airflow in a lung model which is necessary to the study of the deposition of toxicants and therapeutic aerosols.« less
Genetic Algorithm (GA)-Based Inclinometer Layout Optimization.
Liang, Weijie; Zhang, Ping; Chen, Xianping; Cai, Miao; Yang, Daoguo
2015-04-17
This paper presents numerical simulation results of an airflow inclinometer with sensitivity studies and thermal optimization of the printed circuit board (PCB) layout for an airflow inclinometer based on a genetic algorithm (GA). Due to the working principle of the gas sensor, the changes of the ambient temperature may cause dramatic voltage drifts of sensors. Therefore, eliminating the influence of the external environment for the airflow is essential for the performance and reliability of an airflow inclinometer. In this paper, the mechanism of an airflow inclinometer and the influence of different ambient temperatures on the sensitivity of the inclinometer will be examined by the ANSYS-FLOTRAN CFD program. The results show that with changes of the ambient temperature on the sensing element, the sensitivity of the airflow inclinometer is inversely proportional to the ambient temperature and decreases when the ambient temperature increases. GA is used to optimize the PCB thermal layout of the inclinometer. The finite-element simulation method (ANSYS) is introduced to simulate and verify the results of our optimal thermal layout, and the results indicate that the optimal PCB layout greatly improves (by more than 50%) the sensitivity of the inclinometer. The study may be useful in the design of PCB layouts that are related to sensitivity improvement of gas sensors.
Genetic Algorithm (GA)-Based Inclinometer Layout Optimization
Liang, Weijie; Zhang, Ping; Chen, Xianping; Cai, Miao; Yang, Daoguo
2015-01-01
This paper presents numerical simulation results of an airflow inclinometer with sensitivity studies and thermal optimization of the printed circuit board (PCB) layout for an airflow inclinometer based on a genetic algorithm (GA). Due to the working principle of the gas sensor, the changes of the ambient temperature may cause dramatic voltage drifts of sensors. Therefore, eliminating the influence of the external environment for the airflow is essential for the performance and reliability of an airflow inclinometer. In this paper, the mechanism of an airflow inclinometer and the influence of different ambient temperatures on the sensitivity of the inclinometer will be examined by the ANSYS-FLOTRAN CFD program. The results show that with changes of the ambient temperature on the sensing element, the sensitivity of the airflow inclinometer is inversely proportional to the ambient temperature and decreases when the ambient temperature increases. GA is used to optimize the PCB thermal layout of the inclinometer. The finite-element simulation method (ANSYS) is introduced to simulate and verify the results of our optimal thermal layout, and the results indicate that the optimal PCB layout greatly improves (by more than 50%) the sensitivity of the inclinometer. The study may be useful in the design of PCB layouts that are related to sensitivity improvement of gas sensors. PMID:25897500
Tuberculosis associates with both airflow obstruction and low lung function: BOLD results.
Amaral, André F S; Coton, Sonia; Kato, Bernet; Tan, Wan C; Studnicka, Michael; Janson, Christer; Gislason, Thorarinn; Mannino, David; Bateman, Eric D; Buist, Sonia; Burney, Peter G J
2015-10-01
In small studies and cases series, a history of tuberculosis has been associated with both airflow obstruction, which is characteristic of chronic obstructive pulmonary disease, and restrictive patterns on spirometry. The objective of the present study was to assess the association between a history of tuberculosis and airflow obstruction and spirometric abnormalities in adults.The study was performed in adults, aged 40 years and above, who took part in the multicentre, cross-sectional, general population-based Burden of Obstructive Lung Disease study, and had provided acceptable post-bronchodilator spirometry measurements and information on a history of tuberculosis. The associations between a history of tuberculosis and airflow obstruction and spirometric restriction were assessed within each participating centre, and estimates combined using meta-analysis. These estimates were stratified by high- and low/middle-income countries, according to gross national income.A self-reported history of tuberculosis was associated with airflow obstruction (adjusted odds ratio 2.51, 95% CI 1.83-3.42) and spirometric restriction (adjusted odds ratio 2.13, 95% CI 1.42-3.19).A history of tuberculosis was associated with both airflow obstruction and spirometric restriction, and should be considered as a potentially important cause of obstructive disease and low lung function, particularly where tuberculosis is common. Copyright ©ERS 2015.
Tuberculosis associates with both airflow obstruction and low lung function: BOLD results
Amaral, André F. S.; Coton, Sonia; Kato, Bernet; Tan, Wan C.; Studnicka, Michael; Janson, Christer; Gislason, Thorarinn; Mannino, David; Bateman, Eric D.; Buist, Sonia; Burney, Peter G. J.
2015-01-01
Background In small studies and cases series, a history of tuberculosis has been associated with both airflow obstruction, which is characteristic of chronic obstructive pulmonary disease, and restrictive patterns on spirometry. Objective To assess the association between a history of tuberculosis and airflow obstruction and spirometric abnormalities in adults. Methods The study was performed in adults, aged 40 and above, who took part in the multicentre cross-sectional, general population-based, Burden of Obstructive Lung Disease study, had provided acceptable post-bronchodilator spirometry measurements and information on a history of tuberculosis. The associations between a history of tuberculosis and airflow obstruction and spirometric restriction were assessed within each participating centre, and estimates combined using meta-analysis. These estimates were stratified by high and low/middle income countries, according to gross national income. Results A self-reported history of tuberculosis was associated with airflow obstruction (adjusted odds ratio = 2.51, 95% confidence interval 1.83-3.42) and spirometric restriction (adjusted odds ratio = 2.13, 95% confidence interval 1.42-3.19). Conclusion A history of tuberculosis was associated with both airflow obstruction and spirometric restriction, and should be considered as a potentially important cause of obstructive disease and low lung function, particularly where tuberculosis is common. PMID:26113680
Zhang, Baihua; Li, Jianhua; Yue, Yong; Qian, Wei
2017-01-01
Using computational fluid dynamics (CFD) method, the feasibility of simulating transient airflow in a CT-based airway tree with more than 100 outlets for a whole respiratory period is studied, and the influence of truncations of terminal bronchi on CFD characteristics is investigated. After an airway model with 122 outlets is extracted from CT images, the transient airflow is simulated. Spatial and temporal variations of flow velocity, wall pressure, and wall shear stress are presented; the flow pattern and lobar distribution of air are gotten as well. All results are compared with those of a truncated model with 22 outlets. It is found that the flow pattern shows lobar heterogeneity that the near-wall air in the trachea is inhaled into the upper lobe while the center flow enters the other lobes, and the lobar distribution of air is significantly correlated with the outlet area ratio. The truncation decreases airflow to right and left upper lobes and increases the deviation of airflow distributions between inspiration and expiration. Simulating the transient airflow in an airway tree model with 122 bronchi using CFD is feasible. The model with more terminal bronchi decreases the difference between the lobar distributions at inspiration and at expiration. PMID:29333194
Estimating Vocal Effort from the Aerodynamics of Labial Fricatives: A Feasibility Study.
Meynadier, Yohann; El Hajj, Anita; Pitermann, Michel; Legou, Thierry; Giovanni, Antoine
2017-09-12
Vocal effort in loud voice is produced with increased subglottal pressure during vowels and increased supraglottal pressure during consonants. In the paper, our main objective is to check whether it was supported by a parallel increase in the airflow resistance of the laryngeal articulator and of the supralaryngeal articulator, here the lips. For this comparison, our choice fell on the fricative consonants, as their production allows perfectly synchronous air pressure and airflow measurements. Also, the calculation of the real instantaneous aerodynamic resistance is possible with fricatives-as it is with vowels-whereas it is not possible with plosives. The present feasibility study on a healthy subject is based on direct subglottal and intraoral pressures and airflow measured for /f/ or /v/ and from the contiguous vowel produced in VCVCV nonsense words at different levels of intensity. The results support that the airflow resistances at the lips and that at the larynx are quite parallel. The airflow resistance at the lips during labial fricative production could provide a good picture of the laryngeal resistance during the production of continuous speech. This suggests clinical applications using both noninvasive inferred measurements of subglottal pressure variation and direct noninferred airflow measurements from more natural speech production tasks. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Correlation of Nasal Mucosal Temperature With Subjective Nasal Patency in Healthy Individuals.
Bailey, Ryan S; Casey, Kevin P; Pawar, Sachin S; Garcia, Guilherme J M
2017-01-01
Historically, otolaryngologists have focused on nasal resistance to airflow and minimum airspace cross-sectional area as objective measures of nasal obstruction using methods such as rhinomanometry and acoustic rhinometry. However, subjective sensation of nasal patency may be more associated with activation of cold receptors by inspired air than with respiratory effort. To investigate whether subjective nasal patency correlates with nasal mucosal temperature in healthy individuals. Healthy adult volunteers first completed the Nasal Obstruction Symptom Evaluation (NOSE) and a unilateral visual analog scale to quantify subjective nasal patency. A miniaturized thermocouple sensor was then used to record nasal mucosal temperature bilaterally in 2 locations along the nasal septum: at the vestibule and across from the inferior turbinate head. Nasal mucosal temperature and subjective patency scores in healthy individuals. The 22 healthy adult volunteers (12 [55%] male; mean [SD] age, 28.3 [7.0] years) had a mean (SD) NOSE score of 5.9 (8.4) (range, 0-30) and unilateral VAS score of 1.2 (1.4) (range, 0-5). The range of temperature oscillations during the breathing cycle, defined as the difference between end-expiratory and end-inspiratory temperatures, was greater during deep breaths (mean [SD] change in temperature, 6.2°C [2.6°C]) than during resting breathing (mean [SD] change in temperature, 4.2°C [2.3°C]) in both locations (P < .001). Mucosal temperature measured at the right vestibule had a statistically significant correlation with both right-side visual analog scale score (Pearson r = -0.55; 95% CI, -0.79 to -0.17; P = .008) and NOSE score (Pearson r = -0.47; 95% CI, -0.74 to -0.06; P = .03). No other statistically significant correlations were found between mucosal temperature and subjective nasal patency scores. Nasal mucosal temperature was lower (mean of 1.5°C lower) in the first cavity to be measured, which was the right cavity in all participants. The greater mucosal temperature oscillations during deep breathing are consistent with the common experience that airflow sensation is enhanced during deep breaths, thus supporting the hypothesis that mucosal cooling plays a central role in nasal airflow sensation. A possible correlation was found between subjective nasal patency scores and nasal mucosal temperature, but our results were inconsistent. The higher temperature in the left cavity suggests that the sensor irritated the nasal mucosa, affecting the correlation between patency scores and mucosal temperature. Future studies should consider noncontact temperature sensors to prevent mucosa irritation. NA.
Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.
Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H
1992-01-01
BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192
Horie, Masafumi; Noguchi, Satoshi; Tanaka, Wakae; Goto, Yasushi; Yoshihara, Hisanao; Kawakami, Masaki; Suzuki, Masaru; Sakamoto, Yoshio
2013-01-01
Background Chronic obstructive pulmonary disease is caused mainly by habitual smoking and is common among elderly individuals. It involves not only airflow limitation but also metabolic disorders, leading to increased cardiovascular morbidity and mortality. Objective We evaluated relationships among smoking habits, airflow limitation, and metabolic abnormalities. Methods Between 2001 and 2008, 15,324 school workers (9700 males, 5624 females; age: ≥30 years) underwent medical checkups, including blood tests and spirometry. They also responded to a questionnaire on smoking habits and medical history. Results Airflow limitation was more prevalent in current smokers than in ex-smokers and never-smokers in men and women. The frequency of hypertriglyceridemia was higher in current smokers in all age groups, and those of low high-density-lipoprotein cholesterolemia and diabetes mellitus were higher in current smokers in age groups ≥ 40 s in men, but not in women. There were significant differences in the frequencies of metabolic abnormalities between subjects with airflow limitations and those without in women, but not in men. Smoking index was an independent factor associated with increased frequencies of hypertriglyceridemia (OR 1.015; 95% CI: 1.012–1.018; p<0.0001) and low high-density-lipoprotein cholesterolemia (1.013; 1.010–1.016; p<0.0001) in men. Length of smoking cessation was an independent factor associated with a decreased frequency of hypertriglyceridemia (0.984; 0.975–0.994; p = 0.007). Conclusions Habitual smoking causes high incidences of airflow limitation and metabolic abnormalities. Women, but not men, with airflow limitation had higher frequencies of metabolic abnormalities. PMID:24312268
Horie, Masafumi; Noguchi, Satoshi; Tanaka, Wakae; Goto, Yasushi; Yoshihara, Hisanao; Kawakami, Masaki; Suzuki, Masaru; Sakamoto, Yoshio
2013-01-01
Chronic obstructive pulmonary disease is caused mainly by habitual smoking and is common among elderly individuals. It involves not only airflow limitation but also metabolic disorders, leading to increased cardiovascular morbidity and mortality. We evaluated relationships among smoking habits, airflow limitation, and metabolic abnormalities. Between 2001 and 2008, 15,324 school workers (9700 males, 5624 females; age: ≥ 30 years) underwent medical checkups, including blood tests and spirometry. They also responded to a questionnaire on smoking habits and medical history. Airflow limitation was more prevalent in current smokers than in ex-smokers and never-smokers in men and women. The frequency of hypertriglyceridemia was higher in current smokers in all age groups, and those of low high-density-lipoprotein cholesterolemia and diabetes mellitus were higher in current smokers in age groups ≥ 40 s in men, but not in women. There were significant differences in the frequencies of metabolic abnormalities between subjects with airflow limitations and those without in women, but not in men. Smoking index was an independent factor associated with increased frequencies of hypertriglyceridemia (OR 1.015; 95% CI: 1.012-1.018; p<0.0001) and low high-density-lipoprotein cholesterolemia (1.013; 1.010-1.016; p<0.0001) in men. Length of smoking cessation was an independent factor associated with a decreased frequency of hypertriglyceridemia (0.984; 0.975-0.994; p = 0.007). Habitual smoking causes high incidences of airflow limitation and metabolic abnormalities. Women, but not men, with airflow limitation had higher frequencies of metabolic abnormalities.
Miranda-Fuentes, Antonio; Rodríguez-Lizana, Antonio; Gil, Emilio; Agüera-Vega, J; Gil-Ribes, Jesús A
2015-12-15
Olive is a key crop in Europe, especially in countries around the Mediterranean Basin. Optimising the parameters of a spray is essential for sustainable pesticide use, especially in high-input systems, such as the super-intensive hedgerow system. Parameters may be optimised by adjusting the applied volume and airflow rate of sprays, in addition to the liquid to air proportion and the relationship between air velocity and airflow rate. Two spray experiments using a commercial airblast sprayer were conducted in a super-intensive orchard to study how varying the liquid volume rate (testing volumes of 182, 619, and 1603 l ha(-1)) and volumetric airflow rate (with flow rates of 11.93, 8.90, and 6.15 m(3) s(-1)) influences the coverage parameters and the amount and distribution of deposits in different zones of the canopy.. Our results showed that an increase in the application volume raised the mean deposit and percentage coverage, but decreased the application efficiency, spray penetration, and deposit homogeneity. Furthermore, we found that the volumetric airflow rate had a lower influence on the studied parameters than the liquid volume; however, an increase in the airflow rate improved the application efficiency and homogeneity to a certain threshold, after which the spray quality decreased. This decrease was observed in the high-flow treatment. Our results demonstrate that intermediate liquid volume rates and volumetric airflow rates are required for the optimal spraying of pesticides on super-intensive olive crops, and would reduce current pollution levels. Copyright © 2015 Elsevier B.V. All rights reserved.
Performance Analysis of a Modular Small-Diamter Air Distribution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew; Rudd, Armin
2016-03-01
This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air handler unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses anmore » additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.« less
The Risk Factors and Clinical Course of Asthma with Fixed Airflow Limitation.
Pothirat, Chaicharn; Chaiwong, Warawut; Liwsrisakun, Chalerm; Bumroongkit, Chaiwat; Deesomchok, Athavudh; Theerakittikul, Theerakorn; Limsukon, Atikun; Phetsuk, Nittaya
2016-07-01
To identify risk factors and clinical course of asthma with fixed airflow limitation. A retrospective case-control study of asthma patients was conducted over a 15-month period. Asthma with fixed airflow limitation patients were defined as chronic asthmatics who had both post-bronchodilator (BD) and on-treatment ratio of forced expiratory in first second (FEV1)/forced vital capacity (FVC) persistently less than 0.7, whereas usual chronic asthma patients had post-BD and/or on-treatment ratio of FEV1/FVC more than 0.7. Serial asthma control tests (ACT), medication used, exacerbations were assessed. The risk factors were analyzed using logistic regression. Clinical characteristics between groups were compared using Student’s t-test and Fisher’s exact test. One hundred twenty from 142 eligible subjects were enrolled. They had asthma with fixed airflow limitation (n = 40) and usual chronic asthma (n = 80). Potential risk factors of asthma with fixed airflow limitation included early disease onset (age <15 years) [(adjusted odd ratio (OR) = 3.9, 95% confidence interval (CI) 1.9-8.3)] with longer disease duration (adjusted OR = 8.4, 95% CI 4.6-15.4 for >30 years). Asthma with fixed airflow limitation patients had lower ACT scores (p<0.001), lower level of asthma control (p<0.001), required more asthma medications (p = 0.002), and higher rates of hospitalization (p = 0.001) than usual chronic asthma. The potential risk factors of asthma with fixed airflow limitation were earlier disease onset and longer disease duration. They had poorer asthma control, more medications needed, and higher rates of exacerbation than usual chronic asthma.
2002-10-01
To examine the relationships between baseline risk factors and sustained decrease of visual field (SDVF) and sustained decrease of visual acuity (SDVA). Cohort study of participants in the Advanced Glaucoma Intervention Study (AGIS). This multicenter study enrolled patients between 1988 and 1992 and followed them until 2001; 789 eyes of 591 patients with advanced glaucoma were randomly assigned to one of two surgical sequences, argon laser trabeculoplasty (ALT)-trabeculectomy-trabeculectomy (ATT) or trabeculectomy-ALT-trabeculectomy (TAT). This report is based on data from 747 eyes. Eyes were offered the next intervention in the sequence upon failure of the previous intervention. Failure was based on recurrent intraocular pressure elevation, visual field defect, and disk rim criteria. Study visits occurred every 6 months; potential follow-up ranged from 8 to 13 years. For each intervention sequence, Cox multiple regression analyses were used to examine the baseline characteristics for association with two vision outcomes: SDVF and SDVA. The magnitude of the association is measured by the hazard ratio (HR), where HR for binary variables is the relative change in the hazard (or risk) of the outcome in eyes with the factor divided by the hazard in eyes without the factor, and HR for continuous variables is the relative change in the hazard (or risk) of the outcome in eyes with a unit increase in the factor. Characteristics associated with increased SDVF risk in the ATT sequence are: less baseline visual field defect (hazard ratio [HR] = 0.86, P <.001, 95% CI = 0.82-0.90), male gender (HR = 2.23, P <.001, 1.54-3.23), and worse baseline visual acuity (HR = 0.96, P =.001, 0.94-0.98); in the TAT sequence: less baseline visual field defect (HR = 0.93, P =.001, 0.89-0.97) and diabetes (HR = 1.87, P =.007, 1.18-2.97). Characteristics associated with increased SDVA risk in both treatment sequences are better baseline acuity (ATT: HR = 1.05, P <.001, 1.02-1.09; TAT: HR = 1.06, P <.001, 1.03-1.08), older age (ATT: HR = 1.05, P =.001, 1.02-1.08; TAT: HR = 1.04, P =.002, 1.01-1.06), and less formal education (ATT: HR = 1.92, P =.001, 1.29-2.88; TAT: HR = 1.77, P =.002, 1.22-2.54). For SDVF, risk factors were better baseline visual field in both treatment sequences, male gender, and worse baseline visual acuity in the ATT sequence, and diabetes in the TAT sequence. For SDVA, risk factors in both treatment sequences were better baseline visual acuity, older age, and less formal education.
NASA Astrophysics Data System (ADS)
Tost, Jordi; Ehmel, Fabian; Heidmann, Frank; Olen, Stephanie M.; Bookhagen, Bodo
2018-05-01
The assessment of natural hazards and risk has traditionally been built upon the estimation of threat maps, which are used to depict potential danger posed by a particular hazard throughout a given area. But when a hazard event strikes, infrastructure is a significant factor that can determine if the situation becomes a disaster. The vulnerability of the population in a region does not only depend on the area's local threat, but also on the geographical accessibility of the area. This makes threat maps by themselves insufficient for supporting real-time decision-making, especially for those tasks that involve the use of the road network, such as management of relief operations, aid distribution, or planning of evacuation routes, among others. To overcome this problem, this paper proposes a multidisciplinary approach divided in two parts. First, data fusion of satellite-based threat data and open infrastructure data from OpenStreetMap, introducing a threat-based routing service. Second, the visualization of this data through cartographic generalization and schematization. This emphasizes critical areas along roads in a simple way and allows users to visually evaluate the impact natural hazards may have on infrastructure. We develop and illustrate this methodology with a case study of landslide threat for an area in Colombia.
Mejias, Laura; Komilis, Dimitrios; Gea, Teresa; Sánchez, Antoni
2017-07-01
The aim of this study was to assess the effect of the airflow and of the aeration mode on the composting process of non-urban organic wastes that are found in large quantities worldwide, namely: (i) a fresh, non-digested, sewage sludge (FSS), (ii) an anaerobically digested sewage sludge (ADSS), (iii) cow manure (CM) and (iv) pig sludge (PS). This assessment was done using respirometric indices. Two aeration modes were tested, namely: (a) a constant air flowrate set at three different initial fixed airflow rates, and (b) an oxygen uptake rate (OUR)-controlled airflow rate. The four wastes displayed the same behaviour namely a limited biological activity at low aeration, while, beyond a threshold value, the increase of the airflow did not significantly increase the dynamic respiration indices (DRI 1 max , DRI 24 max and AT 4 ). The threshold airflow rate varied among wastes and ranged from 42NL air kg -1 DMh -1 for CM and from 67 to 77NL air kg -1 DMh -1 for FSS, ADSS and PS. Comparing the two aeration modes tested (constant air flow, OUR controlled air flow), no statistically significant differences were calculated between the respiration activity indices obtained at those two aeration modes. The results can be considered representative for urban and non-urban organic wastes and establish a general procedure to measure the respiration activity without limitations by airflow. This will permit other researchers to provide consistent results during the measurement of the respiration activity. Results indicate that high airflows are not required to establish the maximum respiration activity. This can result in energy savings and the prevention of off-gas treatment problems due to the excessive aeration rate in full scale composting plants. Copyright © 2017 Elsevier Ltd. All rights reserved.
Takiguchi, Hiroto; Takeuchi, Tomoe; Niimi, Kyoko; Tomomatsu, Hiromi; Tomomatsu, Katsuyoshi; Hayama, Naoki; Oguma, Tsuyoshi; Aoki, Takuya; Urano, Tetsuya; Asai, Satomi; Miyachi, Hayato; Asano, Koichiro
2018-01-01
Chronic obstructive pulmonary disease (COPD) mainly develops after long-term exposure to cigarette or biomass fuel smoke, but also occurs in non-smokers with or without a history of asthma. We investigated the proportion and clinical characteristics of non-smokers among middle-aged to elderly subjects with airflow obstruction. We retrospectively analyzed 1,892 subjects aged 40-89 years who underwent routine preoperative spirometry at a tertiary university hospital in Japan. Airflow obstruction was defined as a forced expiratory volume in 1 second (FEV1)/forced vital capacity < 0.7 or as the lower limit of the normal. Among 323 patients presenting with FEV1/forced vital capacity < 0.7, 43 had asthma and 280 did not. Among the non-asthmatic patients with airflow obstruction, 94 (34%) were non-smokers. A larger number of women than men with airflow obstruction had asthma (26% vs. 7.6%, p < 0.001), or were non-smokers among non-asthmatics (72% vs. 20%, p < 0.001). Non-asthmatic non-smokers, rather than non-asthmatic smokers, asthmatic non-smokers, and asthmatic smokers, exhibited better pulmonary function (median FEV1: 79% of predicted FEV1 vs. 73%, 69%, and 66%, respectively, p = 0.005) and less dyspnea on exertion (1% vs. 12%, 12%, and 28%, respectively, p = 0.001). Pulmonary emphysema on thoracic computed tomography was less common in non-smokers (p < 0.001). Using the lower limit of the normal to define airflow obstruction yielded similar results. There are a substantial number of non-smokers with airflow obstruction compatible with COPD in Japan. In this study, airflow obstruction in non-smokers was more common in women and likelier to result in mild functional and pathological abnormalities than in smokers. Further studies are warranted to investigate the long-term prognosis and appropriate management of this population in developed countries, especially in women.
Takiguchi, Hiroto; Takeuchi, Tomoe; Niimi, Kyoko; Tomomatsu, Hiromi; Tomomatsu, Katsuyoshi; Hayama, Naoki; Oguma, Tsuyoshi; Urano, Tetsuya; Asai, Satomi; Miyachi, Hayato; Asano, Koichiro
2018-01-01
Background and objectives Chronic obstructive pulmonary disease (COPD) mainly develops after long-term exposure to cigarette or biomass fuel smoke, but also occurs in non-smokers with or without a history of asthma. We investigated the proportion and clinical characteristics of non-smokers among middle-aged to elderly subjects with airflow obstruction. Methods We retrospectively analyzed 1,892 subjects aged 40–89 years who underwent routine preoperative spirometry at a tertiary university hospital in Japan. Airflow obstruction was defined as a forced expiratory volume in 1 second (FEV1)/forced vital capacity < 0.7 or as the lower limit of the normal. Results Among 323 patients presenting with FEV1/forced vital capacity < 0.7, 43 had asthma and 280 did not. Among the non-asthmatic patients with airflow obstruction, 94 (34%) were non-smokers. A larger number of women than men with airflow obstruction had asthma (26% vs. 7.6%, p < 0.001), or were non-smokers among non-asthmatics (72% vs. 20%, p < 0.001). Non-asthmatic non-smokers, rather than non-asthmatic smokers, asthmatic non-smokers, and asthmatic smokers, exhibited better pulmonary function (median FEV1: 79% of predicted FEV1 vs. 73%, 69%, and 66%, respectively, p = 0.005) and less dyspnea on exertion (1% vs. 12%, 12%, and 28%, respectively, p = 0.001). Pulmonary emphysema on thoracic computed tomography was less common in non-smokers (p < 0.001). Using the lower limit of the normal to define airflow obstruction yielded similar results. Conclusions There are a substantial number of non-smokers with airflow obstruction compatible with COPD in Japan. In this study, airflow obstruction in non-smokers was more common in women and likelier to result in mild functional and pathological abnormalities than in smokers. Further studies are warranted to investigate the long-term prognosis and appropriate management of this population in developed countries, especially in women. PMID:29742176
Hopkins, Raewyn J.; Duan, Fenghai; Chiles, Caroline; Greco, Erin M.; Gamble, Greg D.; Aberle, Denise
2017-01-01
Rationale: Although epidemiological studies consistently show that chronic obstructive pulmonary disease is associated with an increased risk of lung cancer, debate exists as to whether there is a linear relationship between the severity of airflow limitation and lung cancer risk. Objectives: We examined this in a large, prospective study of older heavy smokers from the American College of Radiology Imaging Network subcohort of the National Lung Screening Trial (ACRIN). Airflow limitation was defined by prebronchodilator spirometry subgrouped according to Global Initiative for Chronic Obstructive Lung Disease (GOLD) grades 1–4. Methods: In the National Lung Screening Trial–ACRIN cohort of 18,473 screening participants, 6,436 had airflow limitation (35%) and 12,037 (65%) had no airflow limitation. From these groups, 758 lung cancer cases were prospectively identified. Participants with airflow limitation were stratified according to GOLD groups 1 (n = 1,607), 2 (n = 3,528), 3 (n = 1,083), and 4 (n = 211). Lung cancer incidence at study end (mean follow-up, 6.4 yr) was compared between the GOLD groups and those with no airflow limitation (referent group). Measurements and Main Results: Compared with those with no airflow limitation, where lung cancer incidence was 3.78/1,000 person years, incidence rates increased in a simple linear relationship: GOLD 1 (6.27/1,000 person yr); GOLD 2 (7.86/1,000 person yr); GOLD 3 (10.71/1,000 person yr); and GOLD 4 (13.25/1,000 person yr). All relationships were significant versus the reference group at a P value of 0.0001 or less. Conclusions: In a large prospective study of high-risk cigarette smokers, we report a strong linear relationship between increasing severity of airflow limitation and risk of lung cancer. PMID:28076701
Hazardous sign detection for safety applications in traffic monitoring
NASA Astrophysics Data System (ADS)
Benesova, Wanda; Kottman, Michal; Sidla, Oliver
2012-01-01
The transportation of hazardous goods in public streets systems can pose severe safety threats in case of accidents. One of the solutions for these problems is an automatic detection and registration of vehicles which are marked with dangerous goods signs. We present a prototype system which can detect a trained set of signs in high resolution images under real-world conditions. This paper compares two different methods for the detection: bag of visual words (BoW) procedure and our approach presented as pairs of visual words with Hough voting. The results of an extended series of experiments are provided in this paper. The experiments show that the size of visual vocabulary is crucial and can significantly affect the recognition success rate. Different code-book sizes have been evaluated for this detection task. The best result of the first method BoW was 67% successfully recognized hazardous signs, whereas the second method proposed in this paper - pairs of visual words and Hough voting - reached 94% of correctly detected signs. The experiments are designed to verify the usability of the two proposed approaches in a real-world scenario.
Rossi, Andrea; Butorac-Petanjek, Bojana; Chilosi, Marco; Cosío, Borja G; Flezar, Matjaz; Koulouris, Nikolaos; Marin, José; Miculinic, Neven; Polese, Guido; Samaržija, Miroslav; Skrgat, Sabina; Vassilakopoulos, Theodoros; Vukić-Dugac, Andrea; Zakynthinos, Spyridon; Miravitlles, Marc
2017-01-01
Chronic obstructive pulmonary disease (COPD) is a leading cause of mortality and morbidity worldwide, with high and growing prevalence. Its underdiagnosis and hence under-treatment is a general feature across all countries. This is particularly true for the mild or early stages of the disease, when symptoms do not yet interfere with daily living activities and both patients and doctors are likely to underestimate the presence of the disease. A diagnosis of COPD requires spirometry in subjects with a history of exposure to known risk factors and symptoms. Postbronchodilator forced expiratory volume in 1 second (FEV 1 )/forced vital capacity <0.7 or less than the lower limit of normal confirms the presence of airflow limitation, the severity of which can be measured by FEV 1 % predicted: stage 1 defines COPD with mild airflow limitation, which means postbronchodilator FEV 1 ≥80% predicted. In recent years, an elegant series of studies has shown that "exclusive reliance on spirometry, in patients with mild airflow limitation, may result in underestimation of clinically important physiologic impairment". In fact, exercise tolerance, diffusing capacity, and gas exchange can be impaired in subjects at a mild stage of airflow limitation. Furthermore, growing evidence indicates that smokers without overt abnormal spirometry have respiratory symptoms and undergo therapy. This is an essential issue in COPD. In fact, on one hand, airflow limitation, even mild, can unduly limit the patient's physical activity, with deleterious consequences on quality of life and even survival; on the other hand, particularly in younger subjects, mild airflow limitation might coincide with the early stage of the disease. Therefore, we thought that it was worthwhile to analyze further and discuss this stage of "mild COPD". To this end, representatives of scientific societies from five European countries have met and developed this document to stimulate the attention of the scientific community on COPD with "mild" airflow limitation. The aim of this document is to highlight some key features of this important concept and help the practicing physician to understand better what is behind "mild" COPD. Future research should address two major issues: first, whether mild airflow limitation represents an early stage of COPD and what the mechanisms underlying the evolution to more severe stages of the disease are; and second, not far removed from the first, whether regular treatment should be considered for COPD patients with mild airflow limitation, either to prevent progression of the disease or to encourage and improve physical activity or both.
Minimum airflow reset of single-duct VAV terminal boxes
NASA Astrophysics Data System (ADS)
Cho, Young-Hum
Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and applied to actual systems for performance validation. The results of the theoretical analysis, numeric simulations, and experiments show that the optimal control algorithms can automatically identify the minimum rate of heating airflow under actual working conditions. Improved control helps to stabilize room air temperatures. The vertical difference in the room air temperature was lower than the comfort value. Measurements of room CO2 levels indicate that when the minimum airflow set point was reduced it did not adversely affect the indoor air quality. According to the measured energy results, optimal control algorithms give a lower rate of reheating energy consumption than conventional controls.
Rossi, Andrea; Butorac-Petanjek, Bojana; Chilosi, Marco; Cosío, Borja G; Flezar, Matjaz; Koulouris, Nikolaos; Marin, José; Miculinic, Neven; Polese, Guido; Samaržija, Miroslav; Skrgat, Sabina; Vassilakopoulos, Theodoros; Vukić-Dugac, Andrea; Zakynthinos, Spyridon; Miravitlles, Marc
2017-01-01
Chronic obstructive pulmonary disease (COPD) is a leading cause of mortality and morbidity worldwide, with high and growing prevalence. Its underdiagnosis and hence under-treatment is a general feature across all countries. This is particularly true for the mild or early stages of the disease, when symptoms do not yet interfere with daily living activities and both patients and doctors are likely to underestimate the presence of the disease. A diagnosis of COPD requires spirometry in subjects with a history of exposure to known risk factors and symptoms. Postbronchodilator forced expiratory volume in 1 second (FEV1)/forced vital capacity <0.7 or less than the lower limit of normal confirms the presence of airflow limitation, the severity of which can be measured by FEV1% predicted: stage 1 defines COPD with mild airflow limitation, which means postbronchodilator FEV1 ≥80% predicted. In recent years, an elegant series of studies has shown that “exclusive reliance on spirometry, in patients with mild airflow limitation, may result in underestimation of clinically important physiologic impairment”. In fact, exercise tolerance, diffusing capacity, and gas exchange can be impaired in subjects at a mild stage of airflow limitation. Furthermore, growing evidence indicates that smokers without overt abnormal spirometry have respiratory symptoms and undergo therapy. This is an essential issue in COPD. In fact, on one hand, airflow limitation, even mild, can unduly limit the patient’s physical activity, with deleterious consequences on quality of life and even survival; on the other hand, particularly in younger subjects, mild airflow limitation might coincide with the early stage of the disease. Therefore, we thought that it was worthwhile to analyze further and discuss this stage of “mild COPD”. To this end, representatives of scientific societies from five European countries have met and developed this document to stimulate the attention of the scientific community on COPD with “mild” airflow limitation. The aim of this document is to highlight some key features of this important concept and help the practicing physician to understand better what is behind “mild” COPD. Future research should address two major issues: first, whether mild airflow limitation represents an early stage of COPD and what the mechanisms underlying the evolution to more severe stages of the disease are; and second, not far removed from the first, whether regular treatment should be considered for COPD patients with mild airflow limitation, either to prevent progression of the disease or to encourage and improve physical activity or both. PMID:28919728
29 CFR 1910.101 - Compressed gases (general requirements).
Code of Federal Regulations, 2010 CFR
2010-07-01
... (general requirements). (a) Inspection of compressed gas cylinders. Each employer shall determine that... by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous... those regulations are not applicable, visual and other inspections shall be conducted in accordance with...
29 CFR 1910.101 - Compressed gases (general requirements).
Code of Federal Regulations, 2013 CFR
2013-07-01
... (general requirements). (a) Inspection of compressed gas cylinders. Each employer shall determine that... by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous... those regulations are not applicable, visual and other inspections shall be conducted in accordance with...
29 CFR 1910.101 - Compressed gases (general requirements).
Code of Federal Regulations, 2011 CFR
2011-07-01
... (general requirements). (a) Inspection of compressed gas cylinders. Each employer shall determine that... by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous... those regulations are not applicable, visual and other inspections shall be conducted in accordance with...
29 CFR 1910.101 - Compressed gases (general requirements).
Code of Federal Regulations, 2014 CFR
2014-07-01
... (general requirements). (a) Inspection of compressed gas cylinders. Each employer shall determine that... by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous... those regulations are not applicable, visual and other inspections shall be conducted in accordance with...
29 CFR 1910.101 - Compressed gases (general requirements).
Code of Federal Regulations, 2012 CFR
2012-07-01
... (general requirements). (a) Inspection of compressed gas cylinders. Each employer shall determine that... by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous... those regulations are not applicable, visual and other inspections shall be conducted in accordance with...
Airflow and thrust calibration of an F100 engine, S/N P680059, at selected flight conditions
NASA Technical Reports Server (NTRS)
Biesiadny, T. J.; Lee, D.; Rodriguez, J. R.
1978-01-01
An airflow and thrust calibration of an F100 engine, S/N P680059, was conducted to study airframe propulsion system integration losses in turbofan-powered high-performance aircraft. The tests were conducted with and without thrust augmentation for a variety of simulated flight conditions with emphasis on the transonic regime. The resulting corrected airflow data generalized into one curve with corrected fan speed while corrected gross thrust increased as simulated flight conditions increased. Overall agreement between measured data and computed results was 1 percent for corrected airflow and -1 1/2 percent for gross thrust. The results of an uncertainty analysis are presented for both parameters at each simulated flight condition.
3D visualization of unsteady 2D airplane wake vortices
NASA Technical Reports Server (NTRS)
Ma, Kwan-Liu; Zheng, Z. C.
1994-01-01
Air flowing around the wing tips of an airplane forms horizontal tornado-like vortices that can be dangerous to following aircraft. The dynamics of such vortices, including ground and atmospheric effects, can be predicted by numerical simulation, allowing the safety and capacity of airports to be improved. In this paper, we introduce three-dimensional techniques for visualizing time-dependent, two-dimensional wake vortex computations, and the hazard strength of such vortices near the ground. We describe a vortex core tracing algorithm and a local tiling method to visualize the vortex evolution. The tiling method converts time-dependent, two-dimensional vortex cores into three-dimensional vortex tubes. Finally, a novel approach calculates the induced rolling moment on the following airplane at each grid point within a region near the vortex tubes and thus allows three-dimensional visualization of the hazard strength of the vortices. We also suggest ways of combining multiple visualization methods to present more information simultaneously.
The importance of being top-heavy: Intrinsic stability of flapping flight
NASA Astrophysics Data System (ADS)
Ristroph, Leif; Liu, Bin; Zhang, Jun
2011-11-01
We explore the stability of flapping flight in a model system that consists of a pyramid-shaped object that freely hovers in a vertically oscillating airflow. Such a ``bug'' not only generates sufficient aerodynamic force to keep aloft but also robustly maintains balance during free-flight. Flow visualization reveals that both weight support and intrinsic stability result from the periodic shedding of dipolar vortices. Counter-intuitively, the observed pattern of vortex shedding suggests that stability requires a high center-of-mass, which we verify by comparing the performance of top- and bottom-heavy bugs. Finally, we visit a zoo of other flapping flyers, including Mary Poppins' umbrella, a flying saucer or UFO, and Da Vinci's helicopter.
Katayama, Hirohito; Higo, Takashi; Tokunaga, Yuji; Katoh, Shigeo; Hiyama, Yukio; Morikawa, Kaoru
2008-01-01
A practical, risk-based monitoring approach using the combined data collected from actual experiments and computer simulations was developed for the qualification of an EU GMP Annex 1 Grade B, ISO Class 7 area. This approach can locate and minimize the representative number of sampling points used for microbial contamination risk assessment. We conducted a case study on an aseptic clean room, newly constructed and specifically designed for the use of a restricted access barrier system (RABS). Hotspots were located using three-dimensional airflow analysis based on a previously published empirical measurement method, the three-dimensional airflow analysis. Local mean age of air (LMAA) values were calculated based on computer simulations. Comparable results were found using actual measurements and simulations, demonstrating the potential usefulness of such tools in estimating contamination risks based on the airflow characteristics of a clean room. Intensive microbial monitoring and particle monitoring at the Grade B environmental qualification stage, as well as three-dimensional airflow analysis, were also conducted to reveal contamination hotspots. We found representative hotspots were located at perforated panels covering the air exhausts where the major piston airflows collect in the Grade B room, as well as at any locations within the room that were identified as having stagnant air. However, we also found that the floor surface air around the exit airway of the RABS EU GMP Annex 1 Grade A, ISO Class 5 area was always remarkably clean, possibly due to the immediate sweep of the piston airflow, which prevents dispersed human microbes from falling in a Stokes-type manner on settling plates placed on the floor around the Grade A exit airway. In addition, this airflow is expected to be clean with a significantly low LMAA. Based on these observed results, we propose a simplified daily monitoring program to monitor microbial contamination in Grade B environments. To locate hotspots we propose using a combination of computer simulation, actual airflow measurements, and intensive environmental monitoring at the qualification stage. Thereafter, instead of particle or microbial air monitoring, we recommend the use of microbial surface monitoring at the main air exhaust. These measures would be sufficient to assure the efficiency of the monitoring program, as well as to minimize the number of surface sampling points used in environments surrounding a RABS.
Reducing airflow energy use in multiple zone vav systems
NASA Astrophysics Data System (ADS)
Tukur, Ahmed Gidado
Variable Air Volume (VAV) systems are the most popular HVAC systems in commercial buildings. VAV systems are designed to deliver airflows at design conditions which only occur for a few hours in a year. Minimizing energy use in VAV systems requires reducing the amount of airflow delivered through the system at part load conditions. Air Handling Unit (AHU) fans are the major drivers of airflow in VAV systems and installing a Variable Frequency Drive (VFD) is the most common method of regulating airflow in VAV systems. A VFD drive does not necessarily save energy without use of an appropriate control strategy. Static pressure reset (SPR) is considered to be the most energy efficient control strategy for AHU fans with VFDs installed. The implementation of SPR however has many challenges; for example, rogue zones--zones which have faulty sensors or failed controls and actuators, system dynamics like hunting and system diversity. By investigating the parameters associated with the implementation of SPR in VAV systems, a new, improved, more stable SPR algorithm was developed and validated. This approach was further improved using Fault Detection and Diagnostics (FDD) to eliminate rogue zones. Additionally, a CO2-Demand Control Ventilation (DCV) based minimum airflow control was used to further reduce ventilation airflow and save more energy from SPR. Energy savings ranging from 25% to 51% were recorded in actual buildings with the new SPR algorithm. Finally, a methodology that utilizes historical VAV data was developed to estimate the potential savings that could be realized using SPR. The approach employed first determines an effective system loss coefficient as a function of mean damper position using the historical duct static pressure, VAV damper positions and airflows. Additionally, the historical data is used to identify the maximum mean duct damper position realizable as a result of insuring a sufficient number of VAVs are fully open at any time. Savings are estimated by shifting the damper distribution mean at each time to this maximum value and reducing the static pressure to achieve the same overall system airflow rate. The methodology was tested on three different buildings with varying system characteristics. Savings estimates correlated well to the savings actually realized from SPR. This result has significant implications for energy service providers, who could use the predictions to guarantee savings from SPR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, D.C.; Ober, D.G.; Goodrow, J.T.
1995-09-01
ASTM E 283 ad ASTM E 1424 in conjunction with ASTM C 976 were used to study the effect of airflow on thermal performance of the wall. A typical residential 2 {times} 4 stud wall was constructed and placed on top of a subfloor, making a 2.44 {times} 2.74 m (8 by 9 ft) test specimen. This base wall assembly was then covered with two types of XPS sheathing, various housewraps, a 15{number_sign} felt, and a polyethylene vapor retarder film in 40 different configurations and tested individually per ASTM E 283 and per ASTM C 976. For 24 of themore » 40 C 976 tests, a differential pressure was induced across the test wall as per and ASTM E 1424. Airflows ranged from undetectable airflow at 0 {center_dot} Pa {Delta}P to 1.63 L/s {center_dot} m{sup 2} for the base wall assembly alone. Difference in airflow resistance performance between the ASTM E 283 and ASTM E 1424 test methods were noted. Thermal testing results incorporating both ASTM C 976 and ASTM E 1424 for tests 1--28 produced apparent thermal conductances (C-values) in the range of 0.40 W/m{sup 2} {center_dot} K for a nondetectable airflow level to 1.81 W/m{sup 2} {center_dot} K for an airflow of 1.53 L/s {center_dot} m{sup 2} for the base wall assembly alone with a 20-Pa {Delta}P. The calculated C-value for this base wall assembly was 0.40 W/m{sup 2} {center_dot} K. Test results reveal that airflow rates as low as 0.2 L/s {center_dot} m{sup 2} could produce a 46% increase in apparent C-value. Similar thermal performance differences were revealed when thicker shiplap XPS sheathing was used. Tests were also conducted using an Air-Tight Drywall configuration showing the effect of wind washing on thermal performance. By sealing the gypsum drywall on the base wall assembly tested, the apparent C-value, when exposed to a 12.5 Pa wind pressure, was found to be equivalent to a base wall assembly configuration which allows 0.15 L/s {center_dot} m{sup 2} airflow to penetrate completely through.« less
Investigation of the Rocket Induced Flow Field in a Rectangular Duct
NASA Technical Reports Server (NTRS)
Landrum, D. Brian; Thames, Mignon; Parkinson, Doug; Gautney, Serena; Hawk, Clark
1999-01-01
Several tests were performed on a one-sixth scale Rocket Based Combined Cycle (RBCC) engine model at the University of Alabama in Huntsville. The UAH RBCC facility consists of a rectangular duct with a vertical strut mounted in the center. The scaled strut consists of two supersonic rocket nozzles with an embedded vertical turbine between the rocket nozzles. The tests included mass flow, flow visualization and horizontal pressure traverses. The mass flow test indicated a c:hoked condition when the rocket chamber pressure is between 200 psi and 300 psi. The flow visualization tests narrowed the rocket chamber pressure range from, 250 psi to 300 psi. Also, from this t.est, an assumption of a minimum
Measurement of flow separation in a human vocal folds model
NASA Astrophysics Data System (ADS)
Šidlof, Petr; Doaré, Olivier; Cadot, Olivier; Chaigne, Antoine
2011-07-01
The paper provides experimental data on flow separation from a model of the human vocal folds. Data were measured on a four times scaled physical model, where one vocal fold was fixed and the other oscillated due to fluid-structure interaction. The vocal folds were fabricated from silicone rubber and placed on elastic support in the wall of a transparent wind tunnel. A PIV system was used to visualize the flow fields immediately downstream of the glottis and to measure the velocity fields. From the visualizations, the position of the flow separation point was evaluated using a semiautomatic procedure and plotted for different airflow velocities. The separation point position was quantified relative to the orifice width separately for the left and right vocal folds to account for flow asymmetry. The results indicate that the flow separation point remains close to the narrowest cross-section during most of the vocal fold vibration cycle, but moves significantly further downstream shortly prior to and after glottal closure.
What is normal nasal airflow? A computational study of 22 healthy adults
Zhao, Kai; Jiang, Jianbo
2014-01-01
Objective Nasal airflow is essential for functioning of the human nose. Given individual variation in nasal anatomy, there is yet no consensus what constitutes normal nasal airflow patterns. We attempt to obtain such information that is essential to differentiate disease-related variations. Methods Computational fluid dynamics (CFD) simulated nasal airflow in 22 healthy subjects during resting breathing. Streamline patterns, airflow distributions, velocity profiles, pressure, wall stress, turbulence, and vortical flow characteristics under quasi-steady state were analyzed. Patency ratings, acoustically measured minimum cross-sectional area (MCA), and rhinomanometric nasal resistance (NR) were examined for potential correlations with morphological and airflow-related variables. Results Common features across subjects included: >50% total pressure-drop reached near the inferior turbinate head; wall shear stress, NR, turbulence energy, and vorticity were lower in the turbinate than in the nasal valve region. However, location of the major flow path and coronal velocity distributions varied greatly across individuals. Surprisingly, on average, more flow passed through the middle than the inferior meatus and correlated with better patency ratings (r=-0.65, p<0.01). This middle flow percentage combined with peak post-vestibule nasal heat loss and MCA accounted for >70% of the variance in subjective patency ratings and predicted patency categories with 86% success. Nasal index correlated with forming of the anterior dorsal vortex. Expected for resting breathing, the functional impact for local and total turbulence, vorticity, and helicity was limited. As validation, rhinomanometric NR significantly correlated with CFD simulations (r=0.53, p<0.01). Conclusion Significant variations of nasal airflow found among healthy subjects; Key features may have clinically relevant applications. PMID:24664528
Qi, Shouliang; Zhang, Baihua; Yue, Yong; Shen, Jing; Teng, Yueyang; Qian, Wei; Wu, Jianlin
2018-03-01
Tracheal Bronchus (TB) is a rare congenital anomaly characterized by the presence of an abnormal bronchus originating from the trachea or main bronchi and directed toward the upper lobe. The airflow pattern in tracheobronchial trees of TB subjects is critical, but has not been systemically studied. This study proposes to simulate the airflow using CT image based models and the computational fluid dynamics (CFD) method. Six TB subjects and three health controls (HC) are included. After the geometric model of tracheobronchial tree is extracted from CT images, the spatial distribution of velocity, wall pressure, wall shear stress (WSS) is obtained through CFD simulation, and the lobar distribution of air, flow pattern and global pressure drop are investigated. Compared with HC subjects, the main bronchus angle of TB subjects and the variation of volume are large, while the cross-sectional growth rate is small. High airflow velocity, wall pressure, and WSS are observed locally at the tracheal bronchus, but the global patterns of these measures are still similar to those of HC. The ratio of airflow into the tracheal bronchus accounts for 6.6-15.6% of the inhaled airflow, decreasing the ratio to the right upper lobe from 15.7-21.4% (HC) to 4.9-13.6%. The air into tracheal bronchus originates from the right dorsal near-wall region of the trachea. Tracheal bronchus does not change the global pressure drop which is dependent on multiple variables. Though the tracheobronchial trees of TB subjects present individualized features, several commonalities on the structural and airflow characteristics can be revealed. The observed local alternations might provide new insight into the reason of recurrent local infections, cough and acute respiratory distress related to TB.
Unidirectional pulmonary airflow patterns in the savannah monitor lizard.
Schachner, Emma R; Cieri, Robert L; Butler, James P; Farmer, C G
2014-02-20
The unidirectional airflow patterns in the lungs of birds have long been considered a unique and specialized trait associated with the oxygen demands of flying, their endothermic metabolism and unusual pulmonary architecture. However, the discovery of similar flow patterns in the lungs of crocodilians indicates that this character is probably ancestral for all archosaurs--the group that includes extant birds and crocodilians as well as their extinct relatives, such as pterosaurs and dinosaurs. Unidirectional flow in birds results from aerodynamic valves, rather than from sphincters or other physical mechanisms, and similar aerodynamic valves seem to be present in crocodilians. The anatomical and developmental similarities in the primary and secondary bronchi of birds and crocodilians suggest that these structures and airflow patterns may be homologous. The origin of this pattern is at least as old as the split between crocodilians and birds, which occurred in the Triassic period. Alternatively, this pattern of flow may be even older; this hypothesis can be tested by investigating patterns of airflow in members of the outgroup to birds and crocodilians, the Lepidosauromorpha (tuatara, lizards and snakes). Here we demonstrate region-specific unidirectional airflow in the lungs of the savannah monitor lizard (Varanus exanthematicus). The presence of unidirectional flow in the lungs of V. exanthematicus thus gives rise to two possible evolutionary scenarios: either unidirectional airflow evolved independently in archosaurs and monitor lizards, or these flow patterns are homologous in archosaurs and V. exanthematicus, having evolved only once in ancestral diapsids (the clade encompassing snakes, lizards, crocodilians and birds). If unidirectional airflow is plesiomorphic for Diapsida, this respiratory character can be reconstructed for extinct diapsids, and evolved in a small ectothermic tetrapod during the Palaeozoic era at least a hundred million years before the origin of birds.
NASA Astrophysics Data System (ADS)
Zajic, D.; Pace, J. C.; Whiteman, C. D.; Hoch, S.
2011-12-01
This presentation describes a new facility at Dugway Proving Ground (DPG), Utah that can be used to study airflow over complex terrain, and to evaluate how airflow over a mountain barrier affects wind patterns over adjacent flatter terrain. DPG's primary mission is to conduct testing, training, and operational assessments of chemical and biological weapon systems. These operations require very precise weather forecasts. Most test operations at DPG are conducted on fairly flat test ranges having uniform surface cover, where airflow patterns are generally well-understood. However, the DPG test ranges are located alongside large, isolated mountains, most notably Granite Mountain, Camelback Mountain, and the Cedar Mountains. Airflows generated over, or influenced by, these mountains can affect wind patterns on the test ranges. The new facility, the Granite Mountain Atmospheric Sciences Testbed, or GMAST, is designed to facilitate studies of airflow interactions with topography. This facility will benefit DPG by improving understanding of how mountain airflows interact with the test range conditions. A core infrastructure of weather sensors around and on Granite Mountain has been developed including instrumented towers and remote sensors, along with automated data collection and archival systems. GMAST is expected to be in operation for a number of years and will provide a reference domain for mountain meteorology studies, with data useful for analysts, modelers and theoreticians. Visiting scientists are encouraged to collaborate with DPG personnel to utilize this valuable scientific resource and to add further equipment and scientific designs for both short-term and long-term atmospheric studies. Several of the upcoming MATERHORN (MountAin TERrain atmospHeric mOdeling and obseRvatioNs) project field tests will be conducted at DPG, giving an example of GMAST utilization and collaboration between DPG and visiting scientists.
Eiting, Thomas P.; Perot, J. Blair; Dumont, Elizabeth R.
2015-01-01
The morphology of the nasal cavity in mammals with a good sense of smell includes features that are thought to improve olfactory airflow, such as a dorsal conduit that delivers odours quickly to the olfactory mucosa, an enlarged olfactory recess at the back of the airway, and a clear separation of the olfactory and respiratory regions of the nose. The link between these features and having a good sense of smell has been established by functional examinations of a handful of distantly related mammalian species. In this paper, we provide the first detailed examination of olfactory airflow in a group of closely related species that nevertheless vary in their sense of smell. We study six species of phyllostomid bats that have different airway morphologies and foraging ecologies, which have been linked to differences in olfactory ability or reliance. We hypothesize that differences in morphology correlate with differences in the patterns and rates of airflow, which in turn are consistent with dietary differences. To compare species, we make qualitative and quantitative comparisons of the patterns and rates of airflow through the olfactory region during both inhalation and exhalation across the six species. Contrary to our expectations, we find no clear differences among species in either the patterns of airflow through the airway or in rates of flow through the olfactory region. By and large, olfactory airflow seems to be conserved across species, suggesting that morphological differences appear to be driven by other mechanical demands on the snout, such as breathing and feeding. Olfactory ability may depend on other aspects of the system, such as the neurobiological processing of odours that work within the existing morphology imposed by other functional demands on the nasal cavity. PMID:25520358
Changes in aerodynamics during vocal cord dysfunction.
Frank-Ito, Dennis O; Schulz, Kristine; Vess, Gina; Witsell, David L
2015-02-01
Changes in laryngeal airflow dynamics during episodes of vocal cord dysfunction (VCD) have not been well described. Very little is known about how inspiratory airflow is impacted when the vocal cords transition from normal inhalation state to a paradoxical adducted state; and how much change in laryngeal airflow and resistance occur before symptoms of stridor and air hunger emerge. This study provides new insight on the effects of VCD on respiratory airflow using computational fluid dynamics (CFD) techniques. Computed tomography images of a subject with normal vocal cords opening at the time of scanning were digitally modified to mimic an episode of VCD. To quantify and compare changes in inspiratory flow during VCD attack and normal inhalation, steady-state, laminar simulations were performed for three different breathing rates. Pressure-flow analysis during VCD revealed that increasing inspiratory effort is not as efficient as in normal inhalation. Airflow resistance at the epiglottis was higher in the normal state (0.04Pa.s/mL versus 0.02Pa.s/mL) than in VCD; while resistance at the glottis and trachea remained roughly the same (0.04Pa.s/mL) during normal inhalation, it escalated during VCD (0.11Pa.s/mL and 0.13Pa.s/mL at the glottis and trachea, respectively). Peak airflow velocity and vorticity occurred around the glottis during VCD, and at the epiglottis during normal inhalation. This pilot study demonstrates that attempting to force more inspired air will yield greater glottal resistance during VCD. Furthermore, there were evidence of abrupt laryngeal pressure gradient, chaotic airflow and high concentration of shear stresses in the glottal region. Copyright © 2014 Elsevier Ltd. All rights reserved.
Alsved, M; Civilis, A; Ekolind, P; Tammelin, A; Andersson, A Erichsen; Jakobsson, J; Svensson, T; Ramstorp, M; Sadrizadeh, S; Larsson, P-A; Bohgard, M; Šantl-Temkiv, T; Löndahl, J
2018-02-01
To evaluate three types of ventilation systems for operating rooms with respect to air cleanliness [in colony-forming units (cfu/m 3 )], energy consumption and comfort of working environment (noise and draught) as reported by surgical team members. Two commonly used ventilation systems, vertical laminar airflow (LAF) and turbulent mixed airflow (TMA), were compared with a newly developed ventilation technique, temperature-controlled airflow (T c AF). The cfu concentrations were measured at three locations in an operating room during 45 orthopaedic procedures: close to the wound (<40cm), at the instrument table and peripherally in the room. The operating team evaluated the comfort of the working environment by answering a questionnaire. LAF and T c AF, but not TMA, resulted in less than 10cfu/m 3 at all measurement locations in the room during surgery. Median values of cfu/m 3 close to the wound (250 samples) were 0 for LAF, 1 for T c AF and 10 for TMA. Peripherally in the room, the cfu concentrations were lowest for T c AF. The cfu concentrations did not scale proportionally with airflow rates. Compared with LAF, the power consumption of T c AF was 28% lower and there was significantly less disturbance from noise and draught. T c AF and LAF remove bacteria more efficiently from the air than TMA, especially close to the wound and at the instrument table. Like LAF, the new T c AF ventilation system maintained very low levels of cfu in the air, but T c AF used substantially less energy and provided a more comfortable working environment than LAF. This enables energy savings with preserved air quality. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Flow Visualization by Elastic Light Scattering in the Boundary Layer of a Supersonic Flow
NASA Technical Reports Server (NTRS)
Herring, G. C.; Hillard, Mervin E., Jr.
2000-01-01
We demonstrate instantaneous flow visualization of the boundary layer region of a Mach 2.5 supersonic flow over a flat plate that is interacting with an impinging shock wave. Tests were performed in the Unitary Plan Wind Tunnel (UPWT) at NASA Langley Research Center. The technique is elastic light scattering using 10-nsec laser pulses at 532 nm. We emphasize that no seed material of any kind, including water (H2O), is purposely added to the flow. The scattered light comes from a residual impurity that normally exists in the flow medium after the air drying process. Thus, the technique described here differs from the traditional vapor-screen method, which is typically accomplished by the addition of extra H2O vapor to the airflow. The flow is visualized with a series of thin two-dimensional light sheets (oriented perpendicular to the streamwise direction) that are located at several positions downstream of the leading edge of the model. This geometry allows the direct observation of the unsteady flow structure in the spanwise dimension of the model and also allows the indirect observation of the boundary layer growth in the streamwise dimension.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corley, Richard A; Minard, Kevin R; Kabilan, Senthil
The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation. These airflows calculations, along with nasal airway geometry determinations, are critical parameters for hybrid CFD/physiologically based pharmacokinetic models that describe the nasal dosimetry of water-soluble or reactive gases and vapors in rabbits. CFD simulations were based upon three-dimensional computational meshes derived from magnetic resonance images of three adult female New Zealand White (NZW) rabbits. In the anterior portion of the nose, the maxillary turbinates of rabbits are considerably more complex than comparable regions inmore » rats, mice, monkeys, or humans. This leads to a greater surface area to volume ratio in this region and thus the potential for increased extraction of water soluble or reactive gases and vapors in the anterior portion of the nose compared to many other species. Although there was considerable interanimal variability in the fine structures of the nasal turbinates and airflows in the anterior portions of the nose, there was remarkable consistency between rabbits in the percentage of total inspired airflows that reached the ethmoid turbinate region (~50%) that is presumably lined with olfactory epithelium. These latter results (airflows reaching the ethmoid turbinate region) were higher than previous published estimates for the male F344 rat (19%) and human (7%). These differences in regional airflows can have significant implications in interspecies extrapolations of nasal dosimetry.« less
Wind observations above an urban river using a new lidar technique, scintillometry and anemometry.
Wood, C R; Pauscher, L; Ward, H C; Kotthaus, S; Barlow, J F; Gouvea, M; Lane, S E; Grimmond, C S B
2013-01-01
Airflow along rivers might provide a key mechanism for ventilation in cities: important for air quality and thermal comfort. Airflow varies in space and time in the vicinity of rivers. Consequently, there is limited utility in point measurements. Ground-based remote sensing offers the opportunity to study 3D airflow in locations which are difficult to observe with conventional approaches. For three months in the winter and spring of 2011, the airflow above the River Thames in central London was observed using a scanning Doppler lidar, a scintillometer and sonic anemometers. First, an inter-comparison showed that lidar-derived mean wind-speed estimates compare almost as well to sonic anemometers (root-mean-square error (rmse) 0.65-0.68 ms(-1)) as comparisons between sonic anemometers (0.35-0.73 ms(-1)). Second, the lidar duo-beam operating strategy provided horizontal transects of wind vectors (comparison with scintillometer rmse 1.12-1.63 ms(-1)) which revealed mean and turbulent airflow across the river and surrounds; in particular, channelled airflow along the river and changes in turbulence quantities consistent with the roughness changes between built and river environments. The results have important consequences for air quality and dispersion around urban rivers, especially given that many cities have high traffic rates on roads located on riverbanks. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hasegawa, Y.; Kawaoka, H.; Yamada, T.; Matsushima, M.; Kawabe, T.; Shikida, M.
2017-12-01
We previously proposed an evaluation method for detecting both respiration and heartbeat signals from the airflow at the mouth (Kawaoka et al 201518th Int. Conf. on Solid-State Sensors, Actuators and Microsystems; Kawaoka et al 2015 IEEE Sensors; Kawaoka et al 2016 Technical Digest IEEE Micro Electro Mechanical Systems Conf.). In the current study, we developed a catheter flow sensor with temperature compensation that uses MEMS technologies and used it to directly detect the breathing airflow in the airway of a rat. The temperature sensors were integrated with the catheter flow sensor. Heaters working as airflow and temperature sensors were produced on polymer film by using the same fabrication process so that the temperature coefficients of their resistances would coincide. As a result, the variation in sensor outputs due to the airflow temperature changes ranging from 20 °C to 34 °C was suppressed to less than 2.5%. The developed catheter flow sensor was inserted into the airway of a rat to detect both respiration and heartbeat signals. The accuracy of the breathing airflow measurements was improved thanks to the temperature compensation. The tidal volume variations between the expired and inspired air were suppressed to within 5%. Heartbeat signal information was extracted from the measured breathing waveforms by applying a discrete Fourier transform.
Adult normative data for phonatory aerodynamics in connected speech.
Lewandowski, Ali; Gillespie, Amanda I; Kridgen, Samantha; Jeong, Kwonho; Yu, Lan; Gartner-Schmidt, Jackie
2018-04-01
To establish normative values for phonatory aerodynamic measurements in connected speech across adult ages and gender. Prospective data collection across group design. One hundred fifty adults aged >18 years without voice complaints were stratified into three equal-age groups (group 1 [ages 18-39 years]; group 2 [ages 40-59 years], and group 3 [ages 60 + years]) and two equal-gender groups (male and female) resulting in 25 participants in each category. Participants read the first four sentences of the Rainbow Passage at comfortable pitch and loudness to obtain a connected speech sample. The following dependent variables were analyzed: breath number, reading passage duration, mean phonatory airflow, inspiratory airflow duration, and expiratory airflow duration. A gender effect was found for mean phonatory airflow, with males showing significantly greater phonatory airflow than females during connected speech (P < .001). Number of breaths was significantly greater for group 3 than group 2 (P < .001) and group 1 (P < .001). Duration, and inspiratory and expiratory airflow durations were all significantly greater for group 3 (P < .001) than group 2 (P < .001) than group 1 (P < .001). This study provides normative data for phonatory aerodynamics in adult connected speech. Significant age and gender effects were observed. Laryngoscope, 128:909-914, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Fine-scale flight strategies of gulls in urban airflows indicate risk and reward in city living
Shepard, Emily L. C.
2016-01-01
Birds modulate their flight paths in relation to regional and global airflows in order to reduce their travel costs. Birds should also respond to fine-scale airflows, although the incidence and value of this remains largely unknown. We resolved the three-dimensional trajectories of gulls flying along a built-up coastline, and used computational fluid dynamic models to examine how gulls reacted to airflows around buildings. Birds systematically altered their flight trajectories with wind conditions to exploit updraughts over features as small as a row of low-rise buildings. This provides the first evidence that human activities can change patterns of space-use in flying birds by altering the profitability of the airscape. At finer scales still, gulls varied their position to select a narrow range of updraught values, rather than exploiting the strongest updraughts available, and their precise positions were consistent with a strategy to increase their velocity control in gusty conditions. Ultimately, strategies such as these could help unmanned aerial vehicles negotiate complex airflows. Overall, airflows around fine-scale features have profound implications for flight control and energy use, and consideration of this could lead to a paradigm-shift in the way ecologists view the urban environment. This article is part of the themed issue ‘Moving in a moving medium: new perspectives on flight’. PMID:27528784
Phase-Contrast MRI and CFD Modeling of Apparent 3He Gas Flow in Rat Pulmonary Airways
Minard, Kevin R.; Kuprat, Andrew P.; Kabilan, Senthil; Jacob, Richard E.; Einstein, Daniel R.; Carson, James P.; Corley, Richard A.
2012-01-01
Phase-contrast (PC) magnetic resonance imaging (MRI) with hyperpolarized 3He is potentially useful for developing and testing patient-specific models of pulmonary airflow. One challenge, however, is that PC-MRI provides apparent values of local 3He velocity that not only depend on actual airflow but also on gas diffusion. This not only blurs laminar flow patterns in narrow airways but also introduces anomalous airflow structure that reflects gas-wall interactions. Here, both effects are predicted in a live rat using computational fluid dynamics (CFD), and for the first time, simulated patterns of apparent 3He gas velocity are compared with in-vivo PC-MRI. Results show 1) that correlations (R2) between measured and simulated airflow patterns increase from 0.23 to 0.79 simply by accounting for apparent 3He transport, and 2) that remaining differences are mainly due to uncertain airway segmentation and partial volume effects stemming from relatively coarse MRI resolution. Higher-fidelity testing of pulmonary airflow predictions should therefore be possible with future imaging improvements. PMID:22771528
Study on airflow characteristics in the semi-closed irregular narrow flow channel
NASA Astrophysics Data System (ADS)
Jin, Yuzhen; Hu, Xiaodong; Zhu, Linhang; Hu, Xudong; Jin, Yingzi
2016-04-01
The air-jet loom is widely used in the textile industry. The interaction mechanism of airflow and yarn is not clear in such a narrow flow channel, the gas consumption is relatively large, the yarn motion is unstable and the weft insertion is often interrupted during the operation. In order to study the characteristics of the semi-closed flow field in profiled dents, the momentum conservation equation is modified and the model parameters and boundary conditions are set. Compared with the different r, the ratio of profiled dent's thickness and gap, the results show that the smaller the r is, the smaller the velocity fluctuations of the airflow is. When the angle of profiled dents α is close to zero, the diffusion of the airflow will be less. The experiment is also conducted to verify the result of the simulation with a high-speed camera and pressure sensor in profiled dents. The airflow characteristics in the semi-closed irregular narrow flow channel in the paper would provide the theoretical basis for optimizing the weft insertion process of the air-jet loom.
Phase-contrast MRI and CFD modeling of apparent 3He gas flow in rat pulmonary airways
NASA Astrophysics Data System (ADS)
Minard, Kevin R.; Kuprat, Andrew P.; Kabilan, Senthil; Jacob, Richard E.; Einstein, Daniel R.; Carson, James P.; Corley, Richard A.
2012-08-01
Phase-contrast (PC) magnetic resonance imaging (MRI) with hyperpolarized 3He is potentially useful for developing and testing patient-specific models of pulmonary airflow. One challenge, however, is that PC-MRI provides apparent values of local 3He velocity that not only depend on actual airflow but also on gas diffusion. This not only blurs laminar flow patterns in narrow airways but also introduces anomalous airflow structure that reflects gas-wall interactions. Here, both effects are predicted in a live rat using computational fluid dynamics (CFD), and for the first time, simulated patterns of apparent 3He gas velocity are compared with in vivo PC-MRI. Results show (1) that correlations (R2) between measured and simulated airflow patterns increase from 0.23 to 0.79 simply by accounting for apparent 3He transport, and (2) that remaining differences are mainly due to uncertain airway segmentation and partial volume effects stemming from relatively coarse MRI resolution. Higher-fidelity testing of pulmonary airflow predictions should therefore be possible with future imaging improvements.
The behavior of a macroscopic granular material in vortex flow
NASA Astrophysics Data System (ADS)
Nishikawa, Asami
A granular material is defined as a collection of discrete particles such as powder and grain. Granular materials display a large number of complex behaviors. In this project, the behavior of macroscopic granular materials under tornado-like vortex airflow, with varying airflow velocity, was observed and studied. The experimental system was composed of a 9.20-cm inner diameter acrylic pipe with a metal mesh bottom holding the particles, a PVC duct, and an airflow source controlled by a variable auto-transformer, and a power-meter. A fixed fan blade was attached to the duct's inner wall to create a tornado-like vortex airflow from straight flow. As the airflow velocity was increased gradually, the behavior of a set of same-diameter granular materials was observed. The observed behaviors were classified into six phases based on the macroscopic mechanical dynamics. Through this project, we gained insights on the significant parameters for a computer simulation of a similar system by Heath Rice [5]. Comparing computationally and experimentally observed phase diagrams, we can see similar structure. The experimental observations showed the effect of initial arrangement of particles on the phase transitions.
Rocky Mountain Research Station USDA Forest Service
2004-01-01
Many managers and policymakers guided by the National Environmental Policy Act process want to understand the scientific principles on which they can base fuel treatments for reducing the size and severity of wildfires. These Forest Structure and Fire Hazard fact sheets discuss how to estimate fire hazard, how to visualize fuel treatments, and how the role of...
Visual performance for trip hazard detection when using incandescent and led miner cap lamps.
Sammarco, John J; Gallagher, Sean; Reyes, Miguel
2010-04-01
Accident data for 2003-2007 indicate that slip, trip, and falls (STFs) are the second leading accident class (17.8%, n=2,441) of lost-time injuries in underground mining. Proper lighting plays a critical role in enabling miners to detect STF hazards in this environment. Often, the only lighting available to the miner is from a cap lamp worn on the miner's helmet. The focus of this research was to determine if the spectral content of light from light-emitting diode (LED) cap lamps enabled visual performance improvements for the detection of tripping hazards as compared to incandescent cap lamps that are traditionally used in underground mining. A secondary objective was to determine the effects of aging on visual performance. The visual performance of 30 subjects was quantified by measuring each subject's speed and accuracy in detecting objects positioned on the floor both in the near field, at 1.83 meters, and far field, at 3.66 meters. Near field objects were positioned at 0 degrees and +/-20 degrees off axis, while far field objects were positioned at 0 degrees and +/-10 degrees off axis. Three age groups were designated: group A consisted of subjects 18 to 25 years old, group B consisted of subjects 40 to 50 years old, and group C consisted of subjects 51 years and older. Results of the visual performance comparison for a commercially available LED, a prototype LED, and an incandescent cap lamp indicate that the location of objects on the floor, the type of cap lamp used, and subject age all had significant influences on the time required to identify potential trip hazards. The LED-based cap lamps enabled detection times that were an average of 0.96 seconds faster compared to the incandescent cap lamp. Use of the LED cap lamps resulted in average detection times that were about 13.6% faster than those recorded for the incandescent cap lamp. The visual performance differences between the commercially available LED and prototype LED cap lamp were not statistically significant. It can be inferred from this data that the spectral content from LED-based cap lamps could enable significant visual performance improvements for miners in the detection of trip hazards. Published by Elsevier Ltd.
Control method for turbocharged diesel engines having exhaust gas recirculation
Kolmanovsky, Ilya V.; Jankovic, Mrdjan J; Jankovic, Miroslava
2000-03-14
A method of controlling the airflow into a compression ignition engine having an EGR and a VGT. The control strategy includes the steps of generating desired EGR and VGT turbine mass flow rates as a function of the desired and measured compressor mass airflow values and exhaust manifold pressure values. The desired compressor mass airflow and exhaust manifold pressure values are generated as a function of the operator-requested fueling rate and engine speed. The EGR and VGT turbine mass flow rates are then inverted to corresponding EGR and VGT actuator positions to achieve the desired compressor mass airflow rate and exhaust manifold pressure. The control strategy also includes a method of estimating the intake manifold pressure used in generating the EGR valve and VGT turbine positions.
NASA Technical Reports Server (NTRS)
Mitchell, G. A.; Sanders, B. W.
1975-01-01
The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. System variations included several stability bypass entrance configurations. Poppet valves controlled the bypass airflow. The inlet stable airflow range achieved with each configuration was determined for both steady state conditions and internal pulse transients. Results are compared with those obtained without a stability bypass system. Transient results were also obtained for the inlet with a choke point at the diffuser exit and for the inlet with large and small stability bypass plenum volumes. Poppet valves at the stability bypass exit provided the inlet with a stable airflow range of 20 percent or greater at all static and transient conditions.
Numerical simulation of airflow around the evaporator in the closed space
NASA Astrophysics Data System (ADS)
Puchor, Tomáš; Banovčan, Roman; Lenhard, Richard
2018-06-01
The article deals with a numerical simulation of the forced airflow around a evaporator with the finned tubes in the electrotechnical box, by finite volume method in the program ANSYS Workbench. The work contains an analysis of the impact of forced airflow on the evaporator with the various seated the electrical components. The aim of the work is to find out the most effective way of heat dissipation by forced convection from the electrical components in the closed space with lowest pressure loss.
Rocky Mountain Research Station USDA Forest Service
2004-01-01
The software described in this fact sheet provides managers with tools for visualizing forest and fuels information. Computer-based landscape simulations can help visualize stand and landscape conditions and the effects of different management treatments and fuel changes over time. These visualizations can assist forest planning by considering a range of management...
NASA Astrophysics Data System (ADS)
Yan, Huijie; Yang, Liang; Qi, Xiaohua; Ren, Chunsheng
2015-02-01
The effect of a DC bias on the electrohydrodynamics (EHD) force induced by a surface dielectric barrier AC discharge actuator for airflow control at the atmospheric pressure is investigated. The measurement of the surface potential due to charge deposition at different DC biases is carried out by using a special designed corona like discharge potential probe. From the surface potential data, the plasma electromotive force is shown not affected much by the DC biases except for some reduction of the DC bias near the exposed electrode edge for the sheath-like configuration. The total thrust is measured by an analytical balance, and an almost linear relationship to the potential voltage at the exposed electrode edge is found for the direct thrust force. The temporally averaged ionic wind characteristics are investigated by Pitot tube sensor and schlieren visualization system. It is found that the ionic wind velocity profiles with different DC biases are almost the same in the AC discharge plasma area but gradually diversified in the further downstream area as well as the upper space away from the discharge plasma area. Also, the DC bias can significantly modify the topology of the ionic wind produced by the AC discharge actuator. These results can provide an insight into how the DC biases to affect the force generation.
Inspiratory flow pattern in humans.
Lafortuna, C L; Minetti, A E; Mognoni, P
1984-10-01
The theoretical estimation of the mechanical work of breathing during inspiration at rest is based on the common assumption that the inspiratory airflow wave is a sine function of time. Different analytical studies have pointed out that from an energetic point of view a rectangular wave is more economical than a sine wave. Visual inspection of inspiratory flow waves recorded during exercise in humans and various animals suggests that a trend toward a rectangular flow wave may be a possible systematic response of the respiratory system. To test this hypothesis, the harmonic content of inspiratory flow waves that were recorded in six healthy subjects at rest, during exercise hyperventilation, and during a maximum voluntary ventilation (MVV) maneuver were evaluated by a Fourier analysis, and the results were compared with those obtained on sinusoidal and rectangular models. The dynamic work inherent in the experimental waves and in the sine-wave model was practically the same at rest; during exercise hyperventilation and MVV, the experimental wave was approximately 16-20% more economical than the sinusoidal one. It was concluded that even though at rest the sinusoidal model is a reasonably good approximation of inspiratory flow, during exercise and MVV, a physiological controller is probably operating in humans that can select a more economical inspiratory pattern. Other peculiarities of airflow wave during hyperventilation and some optimization criteria are also discussed.
An updated model of induced airflow in the unsaturated zone
Baehr, Arthur L.; Joss, Craig J.
1995-01-01
Simulation of induced movement of air in the unsaturated zone provides a method to determine permeability and to design vapor extraction remediation systems. A previously published solution to the airflow equation for the case in which the unsaturated zone is separated from the atmosphere by a layer of lower permeability (such as a clay layer) has been superseded. The new solution simulates airflow through the layer of lower permeability more rigorously by defining the leakage in terms of the upper boundary condition rather than by adding a leakage term to the governing airflow equation. This note presents the derivation of the new solution. Formulas for steady state pressure, specific discharge, and mass flow in the domain are obtained for the new model and for the case in which the unsaturated zone is in direct contact with the atmosphere.
A general introduction to aeroacoustics and atmospheric sound
NASA Technical Reports Server (NTRS)
Lighthill, James
1992-01-01
A single unifying principle (based upon the nonlinear 'momentum-flux' effects produced when different components of a motion transport different components of its momentum) is used to give a broad scientific background to several aspects of the interaction between airflows and atmospheric sound. First, it treats the generation of sound by airflows of many different types. These include, for example, jet-like flows involving convected turbulent motions (with the resulting aeroacoustic radiation sensitively dependent on the Mach number of convection) and they include, as an extreme case, the supersonic 'boom' (shock waves generated by a supersonically convected flow pattern). Next, an analysis is given of sound propagation through nonuniformly moving airflows, and the exchange is quantified of energy between flow and sound; while, finally, problems are examined of how sound waves 'on their own' may generate the airflows known as acoustic streaming.
Wei, Chia-Ling; Lin, Yu-Chen; Chen, Tse-An; Lin, Ren-Yi; Liu, Tin-Hao
2015-02-01
An airflow sensing chip, which integrates MEMS sensors with their CMOS signal processing circuits into a single chip, is proposed for respiration detection. Three micro-cantilever-based airflow sensors were designed and fabricated using a 0.35 μm CMOS/MEMS 2P4M mixed-signal polycide process. Two main differences were present among these three designs: they were either metal-covered or metal-free structures, and had either bridge-type or fixed-type reference resistors. The performances of these sensors were measured and compared, including temperature sensitivity and airflow sensitivity. Based on the measured results, the metal-free structure with fixed-type reference resistors is recommended for use, because it has the highest airflow sensitivity and also can effectively reduce the output voltage drift caused by temperature change.
Zhao, Kai; Scherer, Peter W; Hajiloo, Shoreh A; Dalton, Pamela
2004-06-01
Recent studies that have compared CT or MRI images of an individual's nasal anatomy and measures of their olfactory sensitivity have found a correlation between specific anatomical areas and performance on olfactory assessments. Using computational fluid dynamics (CFD) techniques, we have developed a method to quickly (
Chang, Kwang K; Kim, Ki Beom; McQuilling, Mark W; Movahed, Reza
2018-06-01
The purpose of this study was to analyze pharyngeal airflow using both computational fluid dynamics (CFD) and fluid structure interactions (FSI) in obstructive sleep apnea patients before and after maxillomandibular advancement (MMA) surgery. The airflow characteristics before and after surgery were compared with both CFD and FSI. In addition, the presurgery and postsurgery deformations of the airway were evaluated using FSI. Digitized pharyngeal airway models of 2 obstructive sleep apnea patients were generated from cone-beam computed tomography scans before and after MMA surgery. CFD and FSI were used to evaluate the pharyngeal airflow at a maximum inspiration rate of 166 ml per second. Standard steady-state numeric formulations were used for airflow simulations. Airway volume increased, pressure drop decreased, maximum airflow velocity decreased, and airway resistance dropped for both patients after the MMA surgery. These findings occurred in both the CFD and FSI simulations. The FSI simulations showed an area of marked airway deformation in both patients before surgery, but this deformation was negligible after surgery for both patients. Both CFD and FSI simulations produced airflow results that indicated less effort was needed to breathe after MMA surgery. The FSI simulations demonstrated a substantial decrease in airway deformation after surgery. These beneficial changes positively correlated with the large improvements in polysomnography outcomes after MMA surgery. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Kimbell, J S; Frank, D O; Laud, Purushottam; Garcia, G J M; Rhee, J S
2013-10-18
Surgeries to correct nasal airway obstruction (NAO) often have less than desirable outcomes, partly due to the absence of an objective tool to select the most appropriate surgical approach for each patient. Computational fluid dynamics (CFD) models can be used to investigate nasal airflow, but variables need to be identified that can detect surgical changes and correlate with patient symptoms. CFD models were constructed from pre- and post-surgery computed tomography scans for 10 NAO patients showing no evidence of nasal cycling. Steady-state inspiratory airflow, nasal resistance, wall shear stress, and heat flux were computed for the main nasal cavity from nostrils to posterior nasal septum both bilaterally and unilaterally. Paired t-tests indicated that all CFD variables were significantly changed by surgery when calculated on the most obstructed side, and that airflow, nasal resistance, and heat flux were significantly changed bilaterally as well. Moderate linear correlations with patient-reported symptoms were found for airflow, heat flux, unilateral allocation of airflow, and unilateral nasal resistance as a fraction of bilateral nasal resistance when calculated on the most obstructed nasal side, suggesting that these variables may be useful for evaluating the efficacy of nasal surgery objectively. Similarity in the strengths of these correlations suggests that patient-reported symptoms may represent a constellation of effects and that these variables should be tracked concurrently during future virtual surgery planning. © 2013 Elsevier Ltd. All rights reserved.
The fluid dynamics of canine olfaction: unique nasal airflow patterns as an explanation of macrosmia
Craven, Brent A.; Paterson, Eric G.; Settles, Gary S.
2010-01-01
The canine nasal cavity contains hundreds of millions of sensory neurons, located in the olfactory epithelium that lines convoluted nasal turbinates recessed in the rear of the nose. Traditional explanations for canine olfactory acuity, which include large sensory organ size and receptor gene repertoire, overlook the fluid dynamics of odorant transport during sniffing. But odorant transport to the sensory part of the nose is the first critical step in olfaction. Here we report new experimental data on canine sniffing and demonstrate allometric scaling of sniff frequency, inspiratory airflow rate and tidal volume with body mass. Next, a computational fluid dynamics simulation of airflow in an anatomically accurate three-dimensional model of the canine nasal cavity, reconstructed from high-resolution magnetic resonance imaging scans, reveals that, during sniffing, spatially separate odour samples are acquired by each nostril that may be used for bilateral stimulus intensity comparison and odour source localization. Inside the nose, the computation shows that a unique nasal airflow pattern develops during sniffing, which is optimized for odorant transport to the olfactory part of the nose. These results contrast sharply with nasal airflow in the human. We propose that mammalian olfactory function and acuity may largely depend on odorant transport by nasal airflow patterns resulting from either the presence of a highly developed olfactory recess (in macrosmats such as the canine) or the lack of one (in microsmats including humans). PMID:20007171
Image processing for hazard recognition in on-board weather radar
NASA Technical Reports Server (NTRS)
Kelly, Wallace E. (Inventor); Rand, Timothy W. (Inventor); Uckun, Serdar (Inventor); Ruokangas, Corinne C. (Inventor)
2003-01-01
A method of providing weather radar images to a user includes obtaining radar image data corresponding to a weather radar image to be displayed. The radar image data is image processed to identify a feature of the weather radar image which is potentially indicative of a hazardous weather condition. The weather radar image is displayed to the user along with a notification of the existence of the feature which is potentially indicative of the hazardous weather condition. Notification can take the form of textual information regarding the feature, including feature type and proximity information. Notification can also take the form of visually highlighting the feature, for example by forming a visual border around the feature. Other forms of notification can also be used.
Increasing awareness and preparedness by an exhibition and studying the effect of visuals
NASA Astrophysics Data System (ADS)
Charrière, Marie; Bogaard, Thom; Malet, Jean-Philippe; Mostert, Erik
2013-04-01
Damages caused by natural hazards can be reduced not only by protection, management and intervention activities, but also by information and communication to improve awareness and preparedness of local communities and tourists. Risk communication is particularly crucial for mountainous areas, such as the Ubaye Valley (France), as they are affected by multiple hazards and are particularly sensitive to the potential effects of climate and socio-economic changes which may increase the risk associated with natural hazards significantly. An exhibition is a powerful tool to communicate with the general public. It allows1: (1) targeting specific audiences, (2) transmitting technical and scientific knowledge using a suitable language, (3) anchoring the collective memory of past events, (4) visualize and emotionalize the topic of natural hazards, (5) strengthening the communication between peers, and (6) highlighting local resources and knowledge. In addition to these theoretical advantages, an exhibition may fulfill the requirements of a community. In the Ubaye Valley (France), this tool was proposed by the stakeholders themselves to increase awareness and preparedness of the general public. To meet this demand, the exhibition was designed following three general topics: (1) the natural phenomena and their potential consequences on the elements at risk, (2) the management and protection measures (individual and collective) and (3) the evolution of events and knowledge throughout past up to the present and the anticipation of the future situations. Besides being a real risk communication practice, this exhibition will be the setting for an extensive research project studying the effect of the use of visualization tools on the awareness and preparedness of a community. A wide range of visuals (photos, videos, maps, models, animations, multimedia, etc.) will present many dimensions of locally occurring natural hazards and risk problems. The aim of the research is (1) to verify the theoretical advantages of visual communication, such as conveying strong messages and making them easy to remember2, (2) to measure the change of awareness and preparedness after being exposed to such media, and (3) to propose guidelines for further development and use of visual tools for natural hazard risk communication. To conduct this analysis, questionnaires and direct observation will be applied. The first method will allow to measure changes in knowledge and perceptions as the same questionnaire will be filled by visitors prior and after their attendance to the exhibition. Additional items of the questionnaire will deal with the opinions on the different visualization tools, i.e. fulfillment of needs and requirements of the visitors. Direct observation will be used for analyzing the relative attraction of each of the visualization tools. This research will help to determine which tool is more suitable to communicate to the community not only as a whole, but also by its sub-groups, i.e. children or adults, locals or tourists, etc.
Saur, Randi; Hansen, Marianne Bang; Jansen, Anne; Heir, Trond
2017-04-01
To explore the types of risks and hazards that visually impaired individuals face, how they manage potential threats and how reactions to traumatic events are manifested and coped with. Participants were 17 visually impaired individuals who had experienced some kind of potentially traumatic event. Two focus groups and 13 individual interviews were conducted. The participants experienced a variety of hazards and potential threats in their daily life. Fear of daily accidents was more pronounced than fear of disasters. Some participants reported avoiding help-seeking in unsafe situations due to shame at not being able to cope. The ability to be independent was highlighted. Traumatic events were re-experienced through a variety of sense modalities. Fear of labelling and avoidance of potential risks were recurring topics, and the risks of social withdrawal and isolation were addressed. Visual impairment causes a need for predictability and adequate information to increase and prepare for coping and self-efficacy. The results from this study call for greater emphasis on universal design in order to ensure safety and predictability. Fear of being labelled may inhibit people from using assistive devices and adequate coping strategies and seeking professional help in the aftermath of a trauma. Implications for Rehabilitation Visual impairment entails a greater susceptibility to a variety of hazards and potential threats in daily life. This calls for a greater emphasis on universal design in public spaces to ensure confidence and safety. Visual impairment implies a need for predictability and adequate information to prepare for coping and self-efficacy. Rehabilitation professionals should be aware of the need for independence and self-reliance, the possible fear of labelling, avoidance of help-seeking or reluctance to use assistive devices. In rehabilitation after accidents or potential traumatizing events, professionals' knowledge about the needs for information, training and predictability is crucial. The possibility of social withdrawal or isolation should be considered.
Air-flow regulation system for a coal gasifier
Fasching, George E.
1984-01-01
An improved air-flow regulator for a fixed-bed coal gasifier is provided which allows close air-flow regulation from a compressor source even though the pressure variations are too rapid for a single primary control loop to respond. The improved system includes a primary controller to control a valve in the main (large) air supply line to regulate large slow changes in flow. A secondary controller is used to control a smaller, faster acting valve in a secondary (small) air supply line parallel to the main line valve to regulate rapid cyclic deviations in air flow. A low-pass filter with a time constant of from 20 to 50 seconds couples the output of the secondary controller to the input of the primary controller so that the primary controller only responds to slow changes in the air-flow rate, the faster, cyclic deviations in flow rate sensed and corrected by the secondary controller loop do not reach the primary controller due to the high frequency rejection provided by the filter. This control arrangement provides at least a factor of 5 improvement in air-flow regulation for a coal gasifier in which air is supplied by a reciprocating compressor through a surge tank.
Fuel composition effect on cathode airflow control in fuel cell gas turbine hybrid systems
NASA Astrophysics Data System (ADS)
Zhou, Nana; Zaccaria, Valentina; Tucker, David
2018-04-01
Cathode airflow regulation is considered an effective means for thermal management in solid oxide fuel cell gas turbine (SOFC-GT) hybrid system. However, performance and controllability are observed to vary significantly with different fuel compositions. Because a complete system characterization with any possible fuel composition is not feasible, the need arises for robust controllers. The sufficiency of robust control is dictated by the effective change of operating state given the new composition used. It is possible that controller response could become unstable without a change in the gains from one state to the other. In this paper, cathode airflow transients are analyzed in a SOFC-GT system using syngas as fuel composition, comparing with previous work which used humidified hydrogen. Transfer functions are developed to map the relationship between the airflow bypass and several key variables. The impact of fuel composition on system control is quantified by evaluating the difference between gains and poles in transfer functions. Significant variations in the gains and the poles, more than 20% in most cases, are found in turbine rotational speed and cathode airflow. The results of this work provide a guideline for the development of future control strategies to face fuel composition changes.
Interfacial distribution of mucus under forced expiration in a double bifurcation model
NASA Astrophysics Data System (ADS)
Rajendran, Rahul; Banerjee, Arindam
2017-11-01
Mucus is removed from the lung airways by the rhythmic beating of cilia and the mucus interaction with the turbulent core airflow generated during a cough or forced expiration. The quantity and quality of mucus are adversely altered, impairing mucociliary clearance under chronic pulmonary conditions. Existing studies on airflow induced mucus clearance have established a functional relationship between the airflow rate, mucus properties, flow bias, breathing frequency and clearance; however, the impact of airway branching, gravity, and characterization of primary and secondary flows have not been studied. The focus of the current investigation is the detailed understanding of air-mucus two-phase flow mechanism under steady expiratory airflow in a double bifurcation model. The effect of different airflow rates and mucus viscosities on the flow morphology, mucus layer thickness, mucus clearance and pressure drop across the model will be discussed. The impact of in-plane and out-of-plane configurations of the bifurcation model on the primary and secondary flow structures as well as the mucus distribution will be addressed. In addition, a detailed comparison of the flow structures in the mucus-lined airways, and its corresponding dry wall (no mucus lining) case will be presented.
Laser irradiation effects on thin aluminum plates subjected to surface flow
NASA Astrophysics Data System (ADS)
Jiang, Houman; Zhao, Guomin; Chen, Minsun; Peng, Xin
2016-10-01
The irradiation effects of LD laser on thin aluminum alloy plates are studied in experiments characterized by relatively large laser spot and the presence of 0.3Ma surface airflow. A high speed profilometer is used to record the profile change along a vertical line in the rear surface of the target, and the history of the displacement along the direction of thickness of the central point at the rear surface is obtained. The results are compared with those without airflow and those by C. D. Boley. We think that it is the temperature rise difference along the direction of thickness instead of the pressure difference caused by the airflow that makes the thin target bulge into the incoming beam, no matter whether the airflow is blown or not, and that only when the thin aluminum target is heated thus softened enough by the laser irradiation, can the aerodynamic force by the surface airflow cause non-ignorable localized plastic deformation and result a burn-through without melting in the target. However, though the target isn't softened enough in terms of the pressure difference, it might have experienced notable deformation as it is heated from room temperature to several hundred degree centigrade.
Thermal properties of highly structured composite and aluminium sheets in an aerodynamic tunnel
NASA Astrophysics Data System (ADS)
Kulhavy, Petr; Egert, Josef
This article deals with the thermodynamic behaviour of heat shields - structured metal and composite plates. Experiments have been carried out in a wind tunnel with an additional heating, which simulates the heat source from engine or exhaust pipe and simultaneously the airflow generated during a car movement. The tested sheets with hexagonal structure were a standard commercial made of aluminium and a second manufactured by replication (lamination, diffusion) from glass fabric. The airflow in a parallel way along the sheets was analysed experimentally in order to determine the heat transfer efficiency between surfaces of sheets and surrounding airflow. The temperature on the sheets was chosen to observe the effects of different sheets material, various heat power and airflow velocity. During the experiment a thermal input below the sheets and airflow velocity through the tunnel have been changed. The thermal field distribution on the metal sheet is different than in case of composite sheet. For the composite material the thermal field distribution was more homogeneous. This article describe briefly also methods of obtaining real composite geometry based on scanned data and their reconstruction for using in some future numerical models.
Sugiura, Shinji; Oda, Tatsuya; Aoyagi, Yasuyuki; Matsuo, Ryota; Enomoto, Tsuyoshi; Matsumoto, Kunio; Nakamura, Toshikazu; Satake, Mitsuo; Ochiai, Atsushi; Ohkohchi, Nobuhiro; Nakajima, Mitsutoshi
2007-02-01
Microencapsulation of genetically engineered cells has attracted much attention as an alternative nonviral strategy to gene therapy. Though smaller microcapsules (i.e. less than 300 microm) theoretically have various advantages, technical limitations made it difficult to prove this notion. We have developed a novel microfabricated device, namely a micro-airflow-nozzle (MAN), to produce 100 to 300 microm alginate microcapsules with a narrow size distribution. The MAN is composed of a nozzle with a 60 microm internal diameter for an alginate solution channel and airflow channels next to the nozzle. An alginate solution extruded through the nozzle was sheared by the airflow. The resulting alginate droplets fell directly into a CaCl2 solution, and calcium alginate beads were formed. The device enabled us to successfully encapsulate living cells into 150 microm microcapsules, as well as control microcapsule size by simply changing the airflow rate. The encapsulated cells had a higher growth rate and greater secretion activity of marker protein in 150 microm microcapsules compared to larger microcapsules prepared by conventional methods because of their high diffusion efficiency and effective scaffold surface area. The advantages of smaller microcapsules offer new prospects for the advancement of microencapsulation technology.
NASA Astrophysics Data System (ADS)
Bourke, Jason Michael
This study seeks to restore the internal anatomy within the nasal passages of dinosaurs via the use of comparative anatomical methods along with computational fluid dynamic simulations. Nasal airway descriptions and airflow simulations are described for extant birds, crocodylians, and lizards. These descriptions served as a baseline for airflow within the nasal passages of diapsids. The presence of shared airflow and soft-tissue properties found in the nasal passages of extant diapsids, were used to restore soft tissues within the airways of dinosaurs under the assumption that biologically unfeasible airflow patterns (e.g., lack of air movement in olfactory recess) can serve as signals for missing soft tissues. This methodology was tested on several dinosaur taxa. Restored airways in some taxa revealed the potential presence and likely shape of nasal turbinates. Heat transfer efficiency was tested in two dinosaur species with elaborated nasal passages. Results of that analysis revealed that dinosaur noses were efficient heat exchangers that likely played an integral role in maintaining cephalic thermoregulation. Brain cooling via nasal expansion appears to have been necessary for dinosaurs to have achieved their immense body sizes without overheating their brains.
NASA Technical Reports Server (NTRS)
Watson, Clifford
2010-01-01
Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the twodimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the least-well-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and threedimensional charting gives a visual confirmation of the relationship between causes and their controls
NASA Technical Reports Server (NTRS)
Watson, Clifford C.
2011-01-01
Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the two-dimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the least-well-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and three-dimensional charting gives a visual confirmation of the relationship between causes and their controls.
Risk Presentation Using the Three Dimensions of Likelihood, Severity, and Level of Control
NASA Technical Reports Server (NTRS)
Watson, Clifford
2010-01-01
Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the two-dimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the leastwell-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and three-dimensional charting gives a visual confirmation of the relationship between causes and their controls.
Digital Semaphore: Tactical Implications of QR Code Optical Signaling for Fleet Communications
2013-06-01
Emissions Control (EMCON) and Hazards of Electromagnetic Radiation to Ordnance (HERO) restrict the ability for Naval Vessels to communicate using...importance of visual communications methods is brought to light by discussing emissions control, hazards of electromagnetic radiation to ordnance , and...overview of emissions restrictions including Emissions Control (EMCON) and Hazards of Electromagnetic Radiation to Ordnance (HERO). Chapter VII is
Visual Attention for Solving Multiple-Choice Science Problem: An Eye-Tracking Analysis
ERIC Educational Resources Information Center
Tsai, Meng-Jung; Hou, Huei-Tse; Lai, Meng-Lung; Liu, Wan-Yi; Yang, Fang-Ying
2012-01-01
This study employed an eye-tracking technique to examine students' visual attention when solving a multiple-choice science problem. Six university students participated in a problem-solving task to predict occurrences of landslide hazards from four images representing four combinations of four factors. Participants' responses and visual attention…
Approach-avoidance pattern of visual attention in hazardous drinkers with ambivalence.
Lee, Saerom; Cho, Sungkun; Lee, Jang-Han
2014-03-01
Ambivalence toward alcohol often develops when hazardous drinkers try to quit or to control their drinking. The purpose of this study was to investigate the differences between hazardous drinkers with and without ambivalence toward alcohol in terms of their visual attention to alcohol-related pictures over time using an eye-tracker. The study included 20 hazardous drinkers with ambivalence and 21 hazardous drinkers without ambivalence. The eye movements of the participants were monitored while the participants conducted a free-viewing task in which 20 pairs of alcohol-related pictures and matched control pictures were presented. The results showed that the hazardous drinkers with ambivalence were more attentive to the alcohol-related pictures at first and were more attentive to the control pictures toward the end of the task. On the other hand, the hazardous drinkers without ambivalence were more attentive to the alcohol-related pictures from beginning to end. The findings of this study indicated that ambivalence toward alcohol resulted in the inclination to approach and then avoid alcohol in a consecutive sequence. The present results could be helpful in distinguishing hazardous drinkers who may have ambivalence toward alcohol and identifying the pattern of ambivalence more concretely. Additionally, further studies need to consider the time that is important to measure ambivalence toward alcohol. Copyright © 2013 Elsevier Ltd. All rights reserved.
Airflow elicits a spider's jump towards airborne prey. I. Airflow around a flying blowfly
Klopsch, Christian; Kuhlmann, Hendrik C.; Barth, Friedrich G.
2012-01-01
The hunting spider Cupiennius salei uses airflow generated by flying insects for the guidance of its prey-capture jump. We investigated the velocity field of the airflow generated by a freely flying blowfly close to the flow sensors on the spider's legs. It shows three characteristic phases (I–III). (I) When approaching, the blowfly induces an airflow signal near the spider with only little fluctuation (0.013 ± 0.006 m s−1) and a strength that increases nearly exponentially with time (maximum: 0.164 ± 0.051 m s−1 s.d.). The spider detects this flow while the fly is still 38.4 ± 5.6 mm away. The fluctuation of the airflow above the sensors increases linearly up to 0.037 m s−1 with the fly's altitude. Differences in the time of arrival and intensity of the fly signal at different legs probably inform the spider about the direction to the prey. (II) Phase II abruptly follows phase I with a much higher degree of fluctuation (fluctuation amplitudes: 0.114 ± 0.050 m s−1). It starts when the fly is directly above the sensor and corresponds to the time-dependent flow in the wake below and behind the fly. Its onset indicates to the spider that its prey is now within reach and triggers its jump. The spider derives information on the fly's position from the airflow characteristics, enabling it to properly time its jump. The horizontal velocity of the approaching fly is reflected by the time of arrival differences (ranging from 0.038 to 0.108 s) of the flow at different legs and the exponential velocity growth rate (16–79 s−1) during phase I. (III) The air flow velocity decays again after the fly has passed the spider. PMID:22572032
New CFD tools to evaluate nasal airflow.
Burgos, M A; Sanmiguel-Rojas, E; Del Pino, C; Sevilla-García, M A; Esteban-Ortega, F
2017-08-01
Computational fluid dynamics (CFD) is a mathematical tool to analyse airflow. As currently CFD is not a usual tool for rhinologists, a group of engineers in collaboration with experts in Rhinology have developed a very intuitive CFD software. The program MECOMLAND ® only required snapshots from the patient's cross-sectional (tomographic) images, being the output those results originated by CFD, such as airflow distributions, velocity profiles, pressure, temperature, or wall shear stress. This is useful complementary information to cover diagnosis, prognosis, or follow-up of nasal pathologies based on quantitative magnitudes linked to airflow. In addition, the user-friendly environment NOSELAND ® helps the medical assessment significantly in the post-processing phase with dynamic reports using a 3D endoscopic view. Specialists in Rhinology have been asked for a more intuitive, simple, powerful CFD software to offer more quality and precision in their work to evaluate the nasal airflow. We present MECOMLAND ® and NOSELAND ® which have all the expected characteristics to fulfil this demand and offer a proper assessment with the maximum of quality plus safety for the patient. These programs represent a non-invasive, low-cost (as the CT scan is already performed in every patient) alternative for the functional study of the difficult rhinologic case. To validate the software, we studied two groups of patients from the Ear Nose Throat clinic, a first group with normal noses and a second group presenting septal deviations. Wall shear stresses are lower in the cases of normal noses in comparison with those for septal deviation. Besides, velocity field distributions, pressure drop between nasopharynx and the ambient, and flow rates in each nostril were different among the nasal cavities in the two groups. These software modules open up a promising future to simulate the nasal airflow behaviour in virtual surgery intervention scenarios under different pressure or temperature conditions to understand the effects on nasal airflow.
Improved Cathode Structure for a Direct Methanol Fuel Cell
NASA Technical Reports Server (NTRS)
Valdez, Thomas; Narayanan, Sekharipuram
2005-01-01
An improved cathode structure on a membrane/electrode assembly has been developed for a direct methanol fuel cell, in a continuing effort to realize practical power systems containing such fuel cells. This cathode structure is intended particularly to afford better cell performance at a low airflow rate. A membrane/electrode assembly of the type for which the improved cathode structure was developed (see Figure 1) is fabricated in a process that includes brush painting and spray coating of catalyst layers onto a polymer-electrolyte membrane and onto gas-diffusion backings that also act as current collectors. The aforementioned layers are then dried and hot-pressed together. When completed, the membrane/electrode assembly contains (1) an anode containing a fine metal black of Pt/Ru alloy, (2) a membrane made of Nafion 117 or equivalent (a perfluorosulfonic acid-based hydrophilic, proton-conducting ion-exchange polymer), (3) a cathode structure (in the present case, the improved cathode structure described below), and (4) the electrically conductive gas-diffusion backing layers, which are made of Toray 060(TradeMark)(or equivalent) carbon paper containing between 5 and 6 weight percent of poly(tetrafluoroethylene). The need for an improved cathode structure arises for the following reasons: In the design and operation of a fuel-cell power system, the airflow rate is a critical parameter that determines the overall efficiency, cell voltage, and power density. It is desirable to operate at a low airflow rate in order to obtain thermal and water balance and to minimize the size and mass of the system. The performances of membrane/electrode assemblies of prior design are limited at low airflow rates. Methanol crossover increases the required airflow rate. Hence, one way to reduce the required airflow rate is to reduce the effect of methanol crossover. Improvement of the cathode structure - in particular, addition of hydrophobic particles to the cathode - has been demonstrated to mitigate the effects of crossover and decrease the airflow required.
The use of combined thermal/pressure polyvinylidene fluoride film airflow sensor in polysomnography.
Kryger, Meir; Eiken, Todd; Qin, Li
2013-12-01
The technologies recommended by the American Academy of Sleep Medicine (AASM) to monitor airflow in polysomnography (PSG) include the simultaneous monitoring of two physical variables: air temperature (for thermal airflow) and air pressure (for nasal pressure). To comply with airflow monitoring standards in the sleep lab setting thus often requires the patient to wear two sensors under the nose during testing. We hypothesized that a single combined thermal/pressure sensor using polyvinylidene fluoride (PVDF) film responsive to both airflow temperature and pressure would be effective in documenting abnormal breathing events during sleep. Sixty patients undergoing routine PSG testing to rule out obstructive sleep apnea at two different sleep laboratories were asked to wear a third PVDF airflow sensor in addition to the traditional thermal sensor and pressure sensor. Apnea and hypopnea events were scored by the sleep lab technologists using the AASM guidelines (CMS option) using the thermal sensor for apnea and the pressure sensor for hypopnea (scorer 1). The digital PSG data were also forwarded to an outside registered polysomnographic technologist for scoring of respiratory events detected in the PVDF airflow channels (scorer 2). The Pearson correlation coefficient, r, between apnea and hypopnea indices obtained using the AASM sensors and the combined PVDF sensor was almost unity for the four calculated indices: apnea-hypopnea index (0.990), obstructive apnea index (0.992), hypopnea index (0.958), and central apnea index (1.0). The slope of the four relationships was virtually unity and the coefficient of determination (r (2)) was also close to 1. The results of intraclass correlation coefficients (>0.95) and Bland-Altman plots also provide excellent agreement between the combined PVDF sensor and the AASM sensors. The indices used to calculate apnea severity obtained with the combined PVDF thermal and pressure sensor were equivalent to those obtained using AASM-recommended sensors.
Upper Airway Collapsibility During REM Sleep in Children with the Obstructive Sleep Apnea Syndrome
Huang, Jingtao; Karamessinis, Laurie R.; Pepe, Michelle E.; Glinka, Stephen M.; Samuel, John M.; Gallagher, Paul R.; Marcus, Carole L.
2009-01-01
Study Objectives: In children, most obstructive events occur during rapid eye movement (REM) sleep. We hypothesized that children with the obstructive sleep apnea syndrome (OSAS), in contrast to age-matched control subjects, would not maintain airflow in the face of an upper airway inspiratory pressure drop during REM sleep. Design: During slow wave sleep (SWS) and REM sleep, we measured airflow, inspiratory time, inspiratory time/total respiratory cycle time, respiratory rate, tidal volume, and minute ventilation at a holding pressure at which flow limitation occurred and at 5 cm H2O below the holding pressure in children with OSAS and in control subjects. Setting: Sleep laboratory. Participants: Fourteen children with OSAS and 23 normal control subjects. Results: In both sleep states, control subjects were able to maintain airflow, whereas subjects with OSAS preserved airflow in SWS but had a significant decrease in airflow during REM sleep (change in airflow of 18.58 ± 12.41 mL/s for control subjects vs −44.33 ± 14.09 mL/s for children with OSAS, P = 0.002). Although tidal volume decreased, patients with OSAS were able to maintain minute ventilation by increasing the respiratory rate and also had an increase in inspiratory time and inspiratory time per total respiratory cycle time Conclusion: Children with OSAS do not maintain airflow in the face of upper-airway inspiratory-pressure drops during REM sleep, indicating a more collapsible upper airway, compared with that of control subjects during REM sleep. However, compensatory mechanisms exist to maintain minute ventilation. Local reflexes, central control mechanisms, or both reflexes and control mechanisms need to be further explored to better understand the pathophysiology of this abnormality and the compensation mechanism. Citation: Huang J; Karamessinis LR; Pepe ME; Glinka SM; Samuel JM; Gallagher PR; Marcus CL. Upper airway collapsibility during REM sleep in children with the obstructive sleep apnea syndrome. SLEEP 2009;32(9):1173-1181. PMID:19750922
Structure of the airflow above surface waves
NASA Astrophysics Data System (ADS)
Buckley, Marc; Veron, Fabrice
2016-04-01
Weather, climate and upper ocean patterns are controlled by the exchanges of momentum, heat, mass, and energy across the ocean surface. These fluxes are, in turn, influenced by the small-scale physics at the wavy air-sea interface. We present laboratory measurements of the fine-scale airflow structure above waves, achieved in over 15 different wind-wave conditions, with wave ages Cp/u* ranging from 1.4 to 66.7 (where Cp is the peak phase speed of the waves, and u* the air friction velocity). The experiments were performed in the large (42-m long) wind-wave-current tank at University of Delaware's Air-Sea Interaction laboratory (USA). A combined Particle Image Velocimetry and Laser Induced Fluorescence system was specifically developed for this study, and provided two-dimensional airflow velocity measurement as low as 100 um above the air-water interface. Starting at very low wind speeds (U10~2m/s), we directly observe coherent turbulent structures within the buffer and logarithmic layers of the airflow above the air-water interface, whereby low horizontal velocity air is ejected away from the surface, and higher velocity fluid is swept downward. Wave phase coherent quadrant analysis shows that such turbulent momentum flux events are wave-phase dependent. Airflow separation events are directly observed over young wind waves (Cp/u*<3.7) and counted using measured vorticity and surface viscous stress criteria. Detached high spanwise vorticity layers cause intense wave-coherent turbulence downwind of wave crests, as shown by wave-phase averaging of turbulent momentum fluxes. Mean wave-coherent airflow motions and fluxes also show strong phase-locked patterns, including a sheltering effect, upwind of wave crests over old mechanically generated swells (Cp/u*=31.7), and downwind of crests over young wind waves (Cp/u*=3.7). Over slightly older wind waves (Cp/u* = 6.5), the measured wave-induced airflow perturbations are qualitatively consistent with linear critical layer theory.
Lee, June H; Haselkorn, Tmirah; Borish, Larry; Rasouliyan, Lawrence; Chipps, Bradley E; Wenzel, Sally E
2007-12-01
The Epidemiology and Natural History of Asthma: Outcomes and Treatment Regimens study is among the largest to assess persistent airflow limitation and the first to evaluate a wide range of potential risk factors in high-risk patients with severe or difficult-to-treat asthma. A better understanding is needed regarding factors associated with persistent airway obstruction; this study was performed to determine demographic and clinical characteristics associated with persistent airflow limitation. Data from adult patients (>or= 18 years old) with severe or difficult-to-treat asthma were evaluated. Patients with COPD, obesity with a restrictive respiratory pattern, or a >or= 30 pack-year history of smoking were excluded. Patients with persistent airflow limitation (postbronchodilator FEV1/FVC ratio
MICROPROCESSOR CONTROL OF ROTOGRAVURE AIRFLOWS
The report discusses the technical and economic viability of using micro-processor-based control technology to collect volatile organic compound (VOC) emissions from a paper coating operation. The microprocessor-based control system monitors and controls both the airflow rate and...
NASA Astrophysics Data System (ADS)
Tondji Chendjou, Yvan Wilfried
This Master's thesis is written within the framework of the multidisciplinary international research project CRIAQ MDO-505. This global project consists of the design, manufacture and testing of a morphing wing box capable of changing the shape of the flexible upper skin of a wing using an actuator system installed inside the wing. This changing of the shape generates a delay in the occurrence of the laminar to turbulent transition area, which results in an improvement of the aerodynamic performances of the morphed wing. This thesis is focused on the technologies used to gather the pressure data during the wind tunnel tests, as well as on the post processing methodologies used to characterize the wing airflow. The vibration measurements of the wing and their real-time graphical representation are also presented. The vibration data acquisition system is detailed, and the vibration data analysis confirms the predictions of the flutter analysis performed on the wing prior to wind tunnel testing at the IAR-NRC. The pressure data was collected using 32 highly-sensitive piezoelectric sensors for sensing the pressure fluctuations up to 10 KHz. These sensors were installed along two wing chords, and were further connected to a National Instrument PXI real-time acquisition system. The acquired pressure data was high-pass filtered, analyzed and visualized using Fast Fourier Transform (FFT) and Standard Deviation (SD) approaches to quantify the pressure fluctuations in the wing airflow, as these allow the detection of the laminar to turbulent transition area. Around 30% of the cases tested in the IAR-NRC wind tunnel were optimized for drag reduction by the morphing wing procedure. The obtained pressure measurements results were compared with results obtained by infrared thermography visualization, and were used to validate the numerical simulations. Two analog accelerometers able to sense dynamic accelerations up to +/-16g were installed in both the wing and the aileron boxes to obtain the vibration sensing measurements. The measured accelerations were acquired by an NI real-time acquisition system using LABVIEW software for a real-time graphical visualization. The recorded data were then analyzed and the analysis indicated that no aeroelastic phenomenon occurred on the model during the wind tunnel tests, at speeds of 50 m/s and 80m/s.
NASA Astrophysics Data System (ADS)
Takahashi, Hidetoshi; Tomimatsu, Yutaka; Kobayashi, Takeshi; Isozaki, Akihiro; Itoh, Toshihiro; Maeda, Ryutaro; Matsumoto, Kiyoshi; Shimoyama, Isao
2014-02-01
This paper reports on a smart, intermittent driven particle sensor with an airflow trigger. A lead zirconate titanate cantilever functions as the trigger, which detects an airflow change without requiring a power supply to drive the sensing element. Because an airflow change indicates that the particle concentration has changed, the trigger switches the optical particle counter from sleep mode to active mode only when the particle concentration surrounding the sensor changes. The sensor power consumption in sleep mode is 100 times less than that in the active mode. Thus, this intermittent driven method significantly reduces the total power consumption of the particle sensor. In this paper, we fabricate a prototype of the particle sensor and demonstrate that the optical particle counter can be switched on by the fabricated trigger and thus that the particle concentration can be measured.
Determination of minimum suction level necessary for field dental units.
Charlton, David G
2010-04-01
A significant problem with most field dental units is that their suction is too weak to effectively remove debris from the mouth. The purpose of this study was to determine the minimum clinically acceptable suction level for routine dentistry. A vacuum pump was connected to a high-volume dental evacuation line in a simulated clinical setting and different suction airflow rates were evaluated by nine evaluator dentists for their capability to effectively remove amalgam debris and water. Airflow levels were rated as "clinically acceptable" or "clinically unacceptable" by each evaluator. Data were analyzed using a chi2 test for trend. Analysis indicated a significant linear trend between airflow and ratings (p < 0.0001). The first airflow level considered by all evaluators as producing clinically acceptable suction was 4.5 standard cubic feet per minute (0.127 standard cubic meters per minute). This value should be the minimum level required for all military field dental units.
Difference in airflow obstruction between Hispanic and non-Hispanic White female smokers.
Sood, Akshay; Stidley, Christine A; Picchi, Maria A; Celedón, Juan C; Gilliland, Frank; Crowell, Richard E; Belinsky, Steven A; Tesfaigzi, Yohannes
2008-10-01
Smoking-related respiratory diseases are a major cause of morbidity and mortality. However, the relationship between smoking and respiratory disease has not been well-studied among ethnic minorities in general and among women in particular. The objective of this cross-sectional study was to evaluate the risk of airflow obstruction and to assess lung function among Hispanic and non-Hispanic White (NHW) female smokers in a New Mexico cohort. Participants completed a questionnaire detailing smoking history and underwent spirometry testing. Outcomes studied included airflow obstruction, selected lung function parameters, and chronic mucus hyper-secretion. Chi square, logistic, and linear regression techniques were utilized. Of the 1,433 eligible women participants, 248 (17.3%) were Hispanic; and 319 had airflow obstruction (22.3%). Hispanic smokers were more likely to be current smokers, and report lower pack-years of smoking, compared to NHW smokers (p < 0.05 for all analyses). Further, Hispanic smokers were at a reduced risk of airflow obstruction compared to NHW smokers, with an O.R. of 0.51, 95% C.I. 0.34, 0.78 (p = 0.002) after adjustment for age, BMI, pack-years and duration of smoking, and current smoking status. Following adjustment for covariates, Hispanic smokers also had a higher mean absolute and percent predicted post-bronchodilator FEV(1)/FVC ratio, as well as higher mean percent predicted FEV(1) (p < 0.05 for all analyses). Hispanic female smokers in this New Mexico-based cohort had lower risk of airflow obstruction and better lung function than NHW female smokers. Further, smoking history did not completely explain these associations.
Clinically remitted childhood asthma is associated with airflow obstruction in middle-aged adults.
Omori, Keitaro; Iwamoto, Hiroshi; Yamane, Takashi; Nakashima, Taku; Haruta, Yoshinori; Hattori, Noboru; Yokoyama, Akihito; Kohno, Nobuoki
2017-01-01
While adult asthma has been shown to be a risk factor for COPD, the effect of remitted childhood asthma on adult lung function has not been clarified. The aim of this study was to examine whether remitted childhood asthma is a risk factor for airflow obstruction in a middle-aged general population. A total of 9896 participants (range: 35-60 years) from five healthcare centres were included in the study. The participants were classified into four categories based on the presence or absence of physician-diagnosed childhood/adulthood asthma and asthma symptoms as follows: healthy controls (n = 9154), remitted childhood asthma (n = 287), adulthood-onset asthma (n = 354) and childhood-adulthood asthma (n = 101). The prevalence of respiratory symptoms was similar in both the participants with remitted childhood asthma and healthy controls. The prevalence of airflow obstruction (forced expiratory volume in 1 s (FEV 1 )/forced vital capacity (FVC) < 0.7) was significantly higher in the participants with remitted childhood asthma, those with adult-onset asthma and those with childhood-adulthood asthma (5.2%, 14.4% and 16.8%, respectively) compared with healthy controls (2.2%). Multivariate logistic regression showed that remitted childhood asthma was independently associated with airflow obstruction. Among the participants with remitted childhood asthma, ever-smokers had significantly lower FEV 1 /FVC than never-smokers. Clinically remitted childhood asthma is associated with airflow obstruction in middle-aged adults. Smoking and remitted childhood asthma may be additive factors for the development of airflow obstruction. © 2016 Asian Pacific Society of Respirology.
Silverman, Erin P; Carnaby-Mann, Giselle; Pitts, Teresa; Davenport, Paul; Okun, Michael S; Sapienza, Christine
2014-05-01
Dysphagia and aspiration pneumonia are two causes of morbidity in Parkinson disease (PD). In PD, impaired airway clearance can lead to penetration of foreign material, resulting in a high prevalence of aspiration pneumonia and death. This study examines three different devices for measurement of peak airflow during voluntary cough in healthy control subjects and those with PD. Two simple and low-cost devices for measuring peak cough airflow were compared with the "gold standard" pneumotachograph. Thirty-five healthy control subjects and 35 individuals with PD produced voluntary cough at three perceived strengths (weak, moderate, and strong cough) for each of the three devices. A significant difference in mean peak cough airflow was demonstrated for disease (F[1,56] = 4.0, P < .05) and sex (F[1,56] = 9.59, P < .003) across devices. The digital and analog meters were comparable to the gold standard demonstrating no significant difference (statistical) by device (digital vs analog) in receiver operating characteristic curve analysis. Both devices were discriminative of the presence of PD. The analog and digital peak airflow meters are suitable alternatives to the gold standard pneumotachograph due to their low cost, portability, ease of use, and high sensitivity relative to normative peak cough airflows. Voluntary cough airflow measures may serve as a noninvasive means of screening for aspiration risk in target populations. Additionally, quantification of cough strength through use of predetermined limens for weak, moderate, and strong cough may assist clinicians in better describing and tracking cough strength as a contributing factor to aspiration risk.
Carnaby-Mann, Giselle; Pitts, Teresa; Davenport, Paul; Okun, Michael S.; Sapienza, Christine
2014-01-01
Background: Dysphagia and aspiration pneumonia are two causes of morbidity in Parkinson disease (PD). In PD, impaired airway clearance can lead to penetration of foreign material, resulting in a high prevalence of aspiration pneumonia and death. This study examines three different devices for measurement of peak airflow during voluntary cough in healthy control subjects and those with PD. Two simple and low-cost devices for measuring peak cough airflow were compared with the “gold standard” pneumotachograph. Methods: Thirty-five healthy control subjects and 35 individuals with PD produced voluntary cough at three perceived strengths (weak, moderate, and strong cough) for each of the three devices. Results: A significant difference in mean peak cough airflow was demonstrated for disease (F[1,56] = 4.0, P < .05) and sex (F[1,56] = 9.59, P < .003) across devices. The digital and analog meters were comparable to the gold standard demonstrating no significant difference (statistical) by device (digital vs analog) in receiver operating characteristic curve analysis. Both devices were discriminative of the presence of PD. Conclusions: The analog and digital peak airflow meters are suitable alternatives to the gold standard pneumotachograph due to their low cost, portability, ease of use, and high sensitivity relative to normative peak cough airflows. Voluntary cough airflow measures may serve as a noninvasive means of screening for aspiration risk in target populations. Additionally, quantification of cough strength through use of predetermined limens for weak, moderate, and strong cough may assist clinicians in better describing and tracking cough strength as a contributing factor to aspiration risk. PMID:24264124
Air quality and passenger comfort in an air-conditioned bus micro-environment.
Zhu, Xiaoxuan; Lei, Li; Wang, Xingshen; Zhang, Yinghui
2018-04-12
In this study, passenger comfort and the air pollution status of the micro-environmental conditions in an air-conditioned bus were investigated through questionnaires, field measurements, and a numerical simulation. As a subjective analysis, passengers' perceptions of indoor environmental quality and comfort levels were determined from questionnaires. As an objective analysis, a numerical simulation was conducted using a discrete phase model to determine the diffusion and distribution of pollutants, including particulate matter with a diameter < 10 μm (PM 10 ), which were verified by experimental results. The results revealed poor air quality and dissatisfactory thermal comfort conditions in Jinan's air-conditioned bus system. To solve these problems, three scenarios (schemes A, B, C) were designed to alter the ventilation parameters. According to the results of an improved simulation of these scenarios, reducing or adding air outputs would shorten the time taken to reach steady-state conditions and weaken the airflow or lower the temperature in the cabin. The airflow pathway was closely related to the layout of the air conditioning. Scheme B lowered the temperature by 0.4 K and reduced the airflow by 0.01 m/s, while scheme C reduced the volume concentration of PM 10 to 150 μg/m 3 . Changing the air supply angle could further improve the airflow and reduce the concentration of PM 10 . With regard to the perception of airflow and thermal comfort, the scheme with an airflow provided by a 60° nozzle was considered better, and the concentration of PM 10 was reduced to 130 μg/m 3 .
Measured Performance of a Varied Airflow Small-Diameter Duct System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew
2017-03-01
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Measured Performance of a Varied Airflow Small-Diameter Duct System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poerschke, Andrew
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Implications of Natural Occlusion of Ventilated Racks on Ammonia and Sanitation Practices
Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M
2014-01-01
Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague–Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded. PMID:24602544
Implications of natural occlusion of ventilated racks on ammonia and sanitation practices.
Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M
2014-03-01
Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague-Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded.
Sul, Bora; Wallqvist, Anders; Morris, Michael J; Reifman, Jaques; Rakesh, Vineet
2014-09-01
Obstructive lung diseases in the lower airways are a leading health concern worldwide. To improve our understanding of the pathophysiology of lower airways, we studied airflow characteristics in the lung between the 8th and the 14th generations using a three-dimensional computational fluid dynamics model, where we compared normal and obstructed airways for a range of breathing conditions. We employed a novel technique based on computing the Pearson׳s correlation coefficient to quantitatively characterize the differences in airflow patterns between the normal and obstructed airways. We found that the airflow patterns demonstrated clear differences between normal and diseased conditions for high expiratory flow rates (>2300ml/s), but not for inspiratory flow rates. Moreover, airflow patterns subjected to filtering demonstrated higher sensitivity than airway resistance for differentiating normal and diseased conditions. Further, we showed that wall shear stresses were not only dependent on breathing rates, but also on the distribution of the obstructed sites in the lung: for the same degree of obstruction and breathing rate, we observed as much as two-fold differences in shear stresses. In contrast to previous studies that suggest increased wall shear stress due to obstructions as a possible damage mechanism for small airways, our model demonstrated that for flow rates corresponding to heavy activities, the wall shear stress in both normal and obstructed airways was <0.3Pa, which is within the physiological limit needed to promote respiratory defense mechanisms. In summary, our model enables the study of airflow characteristics that may be impractical to assess experimentally. Published by Elsevier Ltd.
Spirometry, Static Lung Volumes, and Diffusing Capacity.
Vaz Fragoso, Carlos A; Cain, Hilary C; Casaburi, Richard; Lee, Patty J; Iannone, Lynne; Leo-Summers, Linda S; Van Ness, Peter H
2017-09-01
Spirometric Z-scores from the Global Lung Initiative (GLI) rigorously account for age-related changes in lung function and are thus age-appropriate when establishing spirometric impairments, including a restrictive pattern and air-flow obstruction. However, GLI-defined spirometric impairments have not yet been evaluated regarding associations with static lung volumes (total lung capacity [TLC], functional residual capacity [FRC], and residual volume [RV]) and gas exchange (diffusing capacity). We performed a retrospective review of pulmonary function tests in subjects ≥40 y old (mean age 64.6 y), including pre-bronchodilator measures for: spirometry ( n = 2,586), static lung volumes by helium dilution with inspiratory capacity maneuver ( n = 2,586), and hemoglobin-adjusted single-breath diffusing capacity ( n = 2,508). Using multivariable linear regression, adjusted least-squares means (adj LS Means) were calculated for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity. The adj LS Means were expressed with and without height-cubed standardization and stratified by GLI-defined spirometry, including normal ( n = 1,251), restrictive pattern ( n = 663), and air-flow obstruction (mild, [ n = 128]; moderate, [ n = 150]; and severe, [ n = 394]). Relative to normal spirometry, restrictive-pattern had lower adj LS Means for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity ( P ≤ .001). Conversely, relative to normal spirometry, mild, moderate, and severe air-flow obstruction had higher adj LS Means for FRC and RV ( P < .001). However, only mild and moderate air-flow obstruction had higher adj LS Means for TLC ( P < .001), while only moderate and severe air-flow obstruction had higher adj LS Means for RV/TLC ( P < .001) and lower adj LS Means for hemoglobin-adjusted single-breath diffusing capacity ( P < .001). Notably, TLC (calculated as FRC + inspiratory capacity) was not increased in severe air-flow obstruction ( P ≥ .11) because inspiratory capacity decreased with increasing air-flow obstruction ( P < .001), thus opposing the increased FRC ( P < .001). Finally, P values were similar whether adj LS Means were height-cubed standardized. A GLI-defined spirometric restrictive pattern is strongly associated with a restrictive ventilatory defect (decreased TLC, FRC, and RV), while GLI-defined spirometric air-flow obstruction is strongly associated with hyperinflation (increased FRC) and air trapping (increased RV and RV/TLC). Both spirometric impairments were strongly associated with impaired gas exchange (decreased hemoglobin-adjusted single-breath diffusing capacity). Copyright © 2017 by Daedalus Enterprises.
NASA Astrophysics Data System (ADS)
Chung, Y. S.; Kim, Hak-Sung; Chun, Youngsin
2014-05-01
Dust air pollution has been routinely monitored in central Korea for the last two decades. In 2009, there were eight typical episodes of significant dust loadings in the air: four were caused by dust storms from deserts in Mongolia and Northern China, while the remaining were typical cases of anthropogenic air pollution masses arriving from the Yellow Sea and East China. These natural dust loadings occurred with cool northwesterly airflows in the forward side of an intense anticyclone coming from Mongolia and Siberia. The mean concentrations of the four natural dustfall cases for TSP, PM10 and PM2.5 were 632, 480 and 100 μg m-3, respectively. In contrast, the anthropogenic dust-pollution episodes occurred with the warm westerly and southwesterly airflows in the rear side of an anticyclone. This produced a favorable atmospheric and chemical condition for the build-up of anthropogenic dust air pollution in the Yellow Sea. The mean concentrations of the four anthropogenic dust loadings for TSP, PM10 and PM2.5 were 224, 187 and 137 μg m-3, respectively. The contents of fine dust loadings of PM2.5 were comparatively high in the cases of anthropogenic air pollution. High atmospheric concentrations of fine particles in the atmosphere cause poor visibility and constitute a health hazard. Satellite observations clearly showed the movement of dust-pollution masses from Mongolia and Northern China and from the Yellow Sea and East China that caused these dust pollution episodes in Korea.
An experimental investigation of tobacco smoke pollution in cars.
Sendzik, Taryn; Fong, Geoffrey T; Travers, Mark J; Hyland, Andrew
2009-06-01
Tobacco smoke pollution (TSP) has been identified as a serious public health threat. Although the number of jurisdictions that prohibit smoking in public places has increased rapidly, just a few successful attempts have been made to pass similar laws prohibiting smoking in cars, where the cabin space may contribute to concentrated exposure. In particular, TSP constitutes a potentially serious health hazard to children because of prolonged exposure and their small size. The present study investigated the levels of TSP in 18 cars via the measurement of fine respirable particles (<2.5 microns in diameter or PM(2.5)) under a variety of in vivo conditions. Car owners smoked a single cigarette in their cars in each of five controlled air-sampling conditions. Each condition varied on movement of the car, presence of air conditioning, open windows, and combinations of these airflow influences. Smoking just a single cigarette in a car generated extremely high average levels of PM(2.5): more than 3,800 microg/m3 in the condition with the least airflow (motionless car, windows closed). In moderate ventilation conditions (air conditioning or having the smoking driver hold the cigarette next to a half-open window), the average levels of PM(2.5) were reduced but still at significantly high levels (air conditioning = 844 microg/m3; holding cigarette next to a half-open window = 223 microg/m3). This study demonstrates that TSP in cars reaches unhealthy levels, even under realistic ventilation conditions, lending support to efforts occurring across a growing number of jurisdictions to educate people and prohibit smoking in cars in the presence of children.
Hwang, Gi Byoung; Lee, Jung Eun; Nho, Chu Won; Lee, Byung Uk; Lee, Seung Jae; Jung, Jae Hee; Bae, Gwi-Nam
2012-04-01
Bioaerosols have received social and scientific attention because they can be hazardous to human health. Recently, antimicrobial treatments using natural products have been used to improve indoor air quality (IAQ) since they are typically less toxic to humans compared to other antimicrobial substances such as silver, carbon nanotubes, and metal oxides. Few studies, however, have examined how environmental conditions such as the relative humidity (RH), surrounding temperature, and retention time of bacteria on filters affect the filtration and antimicrobial characteristics of a filter treated with such natural products. In this study, we investigated changes in the morphology of the natural nanoparticles, pressure drop, filtration efficiency, and the inactivation rate caused by the short-term effect of humid airflow on antimicrobial fiber filters. Nanoparticles of Sophora flavescens were deposited on the filter media surface using an aerosol process. We observed coalescence and morphological changes of the nanoparticles on fiber filters under humid conditions of an RH >50%. The level of coalescence in these nanoparticles increased with increasing RH. Filters exposed to an RH of 25% have a higher pressure drop than those exposed to an RH >50%. In an inactivation test against Staphylococcus epidermidis bacterial aerosol, the inactivation efficiency at an RH of 25% was higher than that at an RH of 57% or 82%. To effectively apply antimicrobial filters using natural products in the environment, one must characterize the filters under various environmental conditions. Thus, this study provides important information on the use of antimicrobial filters made of natural products. Copyright © 2012 Elsevier B.V. All rights reserved.
Airflow and nanoparticle deposition in a 16-generation tracheobronchial airway model
In order to achieve both manageable simulation and local accuracy of airflow and nanoparticle deposition in a representative human tracheobronchial (TB) region, the complex airway network was decomposed into adjustable triple-bifurcation units, spreading axially and laterally. Gi...
A dynamic ventilation model for gravity sewer networks.
Wang, Y C; Nobi, N; Nguyen, T; Vorreiter, L
2012-01-01
To implement any effective odour and corrosion control technology in the sewer network, it is imperative that the airflow through gravity sewer airspaces be quantified. This paper presents a full dynamic airflow model for gravity sewer systems. The model, which is developed using the finite element method, is a compressible air transport model. The model has been applied to the North Head Sewerage Ocean Outfall System (NSOOS) and calibrated using the air pressure and airflow data collected during October 2008. Although the calibration is focused on forced ventilation, the model can be applied to natural ventilation as well.
Velopharyngeal port status during classical singing.
Tanner, Kristine; Roy, Nelson; Merrill, Ray M; Power, David
2005-12-01
This investigation was undertaken to examine the status of the velopharyngeal (VP) port during classical singing. Using aeromechanical instrumentation, nasal airflow (mL/s), oral pressure (cm H2O), and VP orifice area estimates (cm2) were studied in 10 classically trained sopranos during singing and speaking. Each participant sang and spoke 3 nonsense words-/hampa/, /himpi/, and /humpu/-at 3 loudness levels (loud vs. comfortable vs. soft) and 3 pitches (high vs. comfortable vs. low), using a within-subject experimental design including all possible combinations. In general, nasal airflow, oral pressure, and VP area estimates were significantly greater for singing as compared to speech, and nasal airflow was observed during non-nasal sounds in all participants. Anticipatory nasal airflow was observed in 9 of 10 participants for singing and speaking and was significantly greater during the first vowel in /hampa/ versus /himpi/ and /humpu/. The effect of vowel height on nasal airflow was also significantly influenced by loudness and pitch. The results from this investigation indicate that at least some trained singers experience regular VP opening during classical singing. Vowel height seems to influence this effect. Future research should consider the effects of voice type, gender, experience level, performance ability, and singing style on VP valving in singers.
NASA Astrophysics Data System (ADS)
Gaylord, David R.; Dawson, Paul J.
1987-09-01
The integration of atmospheric soundings from a fully instrumented aircraft with detailed sedimentary and geomorphic analyses of eolian features in the Ferris dune field of south-central Wyoming lends insight into the manner in which topography interacts with airflow to modify eolian activity. Topographically modified airflow results in zones of airflow deceleration, acceleration, and enhanced atmospheric turbulence, all of which influence the surface morphology and sedimentology. Extreme lateral confluence of prevailing airflow produces accelerated, unidirectional winds. These winds correlate with unusually continuous and elongate parabolic dunes that extend into a mountain gap (Windy Gap). Persistently heightened winds produced at the entrance to Windy Gap have resulted in a concentration of active sand dunes that lack slipfaces. Common development of a strongly amplified atmospheric wave analogous to a hydraulic jump in the gap contributes to the formation of a variety of eolian features that mantle the surface of Windy Gap and the Ferris dune field tail. Heightened, unidirectional winds in this zone promote grain-size segregation, the formation of elongated and aligned sand drifts, climbing and falling dunes, elongate scour streaks, and parabolic dunes that have low-angle (<20°) cross-stratification. Deflation of bedrock and loose sediment has been enhanced in the zone of maximum turbulence beneath the hydraulic jump.
NASA Astrophysics Data System (ADS)
Sun, Xiuzhen; Yu, Chi; Wang, Yuefang; Liu, Yingxi
2007-08-01
In this paper, the authors present airflow field characteristics of human upper airway and soft palate movement attitude during breathing. On the basis of the data taken from the spiral computerized tomography images of a healthy person and a patient with Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS), three-dimensional models of upper airway cavity and soft palate are reconstructed by the method of surface rendering. Numerical simulation is performed for airflow in the upper airway and displacement of soft palate by fluid-structure interaction analysis. The reconstructed three-dimensional models precisely preserve the original configuration of upper airways and soft palate. The results of the pressure and velocity distributions in the airflow field are quantitatively determined, and the displacement of soft palate is presented. Pressure gradients of airway are lower for the healthy person and the airflow distribution is quite uniform in the case of free breathing. However, the OSAHS patient remarkably escalates both the pressure and velocity in the upper airway, and causes higher displacement of the soft palate. The present study is useful in revealing pathogenesis and quantitative mutual relationship between configuration and function of the upper airway as well as in diagnosing diseases related to anatomical structure and function of the upper airway.
ERIC Educational Resources Information Center
Walsh, Janet
1982-01-01
Discusses the health hazards of working with the visual display systems of computers, in particular the eye problems associated with long-term use of video display terminals. Excerpts from and ordering information for the National Institute for Occupational Safety and Health report on such hazards are included. (JJD)
Robots, systems, and methods for hazard evaluation and visualization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nielsen, Curtis W.; Bruemmer, David J.; Walton, Miles C.
A robot includes a hazard sensor, a locomotor, and a system controller. The robot senses a hazard intensity at a location of the robot, moves to a new location in response to the hazard intensity, and autonomously repeats the sensing and moving to determine multiple hazard levels at multiple locations. The robot may also include a communicator to communicate the multiple hazard levels to a remote controller. The remote controller includes a communicator for sending user commands to the robot and receiving the hazard levels from the robot. A graphical user interface displays an environment map of the environment proximatemore » the robot and a scale for indicating a hazard intensity. A hazard indicator corresponds to a robot position in the environment map and graphically indicates the hazard intensity at the robot position relative to the scale.« less
Dust: A major environmental hazard on the earth's moon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heiken, G.; Vaniman, D.; Lehnert, B.
1990-01-01
On the Earth's Moon, obvious hazards to humans and machines are created by extreme temperature fluctuations, low gravity, and the virtual absence of any atmosphere. The most important other environmental factor is ionizing radiation. Less obvious environmental hazards that must be considered before establishing a manned presence on the lunar surface are the hazards from micrometeoroid bombardment, the nuisance of electro-statically-charged lunar dust, and an alien visual environment without familiar clues. Before man can establish lunar bases and lunar mining operations, and continue the exploration of that planet, we must develop a means of mitigating these hazards. 4 refs.
Yang, Chao-Yang; Wu, Cheng-Tse
2017-03-01
This research investigated the risks involved in bicycle riding while using various sensory modalities to deliver training information. To understand the risks associated with using bike computers, this study evaluated hazard perception performance through lab-based simulations of authentic riding conditions. Analysing hazard sensitivity (d') of signal detection theory, the rider's response time, and eye glances provided insights into the risks of using bike computers. In this study, 30 participants were tested with eight hazard perception tasks while they maintained a cadence of 60 ± 5 RPM and used bike computers with different sensory displays, namely visual, auditory, and tactile feedback signals. The results indicated that synchronously using different sense organs to receive cadence feedback significantly affects hazard perception performance; direct visual information leads to the worst rider distraction, with a mean sensitivity to hazards (d') of -1.03. For systems with multiple interacting sensory aids, auditory aids were found to result in the greatest reduction in sensitivity to hazards (d' mean = -0.57), whereas tactile sensory aids reduced the degree of rider distraction (d' mean = -0.23). Our work complements existing work in this domain by advancing the understanding of how to design devices that deliver information subtly, thereby preventing disruption of a rider's perception of road hazards. Copyright © 2016 Elsevier Ltd. All rights reserved.
Full-Scale Schlieren Visualization of Commercial Kitchen Ventilation Aerodynamics
NASA Astrophysics Data System (ADS)
Miller, J. D.; Settles, G. S.
1996-11-01
The efficient removal of cooking effluents from commercial kitchens has been identified as the most pressing energy-related issue in the food service industry. A full-scale schlieren optical system with a 2.1x2.7m field-of-view, described at previous APS/DFD meetings, images the convective airflow associated with a typical gas-fired cooking griddle and ventilation hood. Previous attempts to visualize plumes from cooking equipment by smoke and neutrally-buoyant bubbles were not sufficiently keyed to thermal convection. Here, the point where the ventilation hood fails to capture the effluent plume is clearly visible, thus determining the boundary condition for a balanced ventilation system. Further, the strong influence of turbulent entrainment is seen in the behavior of the combustion products vented by the griddle and the interference caused by a makeup-air outlet located too close to the lip of the ventilation hood. Such applications of traditional fluid dynamics techniques and principles are believed to be important to the maturing of ventilation technology. (Research supported by EPRI and IFMA, Inc.)
Hur, Jae-Sik; Kim, Hyoung-Ho; Choi, Jin-Young; Suh, Sang-Ho
2017-01-01
Objective The objective of this study was to investigate the effects of miniscrew-assisted rapid palatal expansion (MARPE) on changes in airflow in the upper airway (UA) of an adult patient with obstructive sleep apnea syndrome (OSAS) using computational fluid-structure interaction analysis. Methods Three-dimensional UA models fabricated from cone beam computed tomography images obtained before (T0) and after (T1) MARPE in an adult patient with OSAS were used for computational fluid dynamics with fluid-structure interaction analysis. Seven and nine cross-sectional planes (interplane distance of 10 mm) in the nasal cavity (NC) and pharynx, respectively, were set along UA. Changes in the cross-sectional area and changes in airflow velocity and pressure, node displacement, and total resistance at maximum inspiration (MI), rest, and maximum expiration (ME) were investigated at each plane after MARPE. Results The cross-sectional areas at most planes in NC and the upper half of the pharynx were significantly increased at T1. Moreover, airflow velocity decreased in the anterior NC at MI and ME and in the nasopharynx and oropharynx at MI. The decrease in velocity was greater in NC than in the pharynx. The airflow pressure in the anterior NC and entire pharynx exhibited a decrease at T1. The amount of node displacement in NC and the pharynx was insignificant at both T0 and T1. Absolute values for the total resistance at MI, rest, and ME were lower at T1 than at T0. Conclusions MARPE improves airflow and decreases resistance in UA; therefore, it may be an effective treatment modality for adult patients with moderate OSAS. PMID:29090123
Gehring, J M; Cho, J-G; Wheatley, J R; Amis, T C
2014-03-01
We examined thermocouple and pressure cannulae responses to oral and nasal airflow using a polyester model of a human face, with patent nasal and oral orifices instrumented with a dual thermocouple (F-ONT2A, Grass) or a dual cannula (0588, Braebon) pressure transducer (± 10 cm H2O, Celesco) system. Tidal airflow was generated using a dual compartment facemask with pneumotachographs (Fleisch 2) connected to the model orifices. During nasal breathing: thermocouple amplitude = 0.38 Ln [pneumotachograph amplitude] + 1.31 and pressure cannula amplitude = 0.93 [pneumotachograph amplitude](2.15); during oral breathing: thermocouple amplitude = 0.44 Ln [pneumotachograph amplitude] + 1.07 and pressure cannula amplitude = 0.33 [pneumotachograph amplitude](1.72); (all range ∼ 0.1-∼ 4.0 L s(-1); r(2) > 0.7). For pneumotachograph amplitudes <1 L s(-1) (linear model) change in thermocouple amplitude/unit change in pneumotachograph amplitude was similar for nasal and oral airflow, whereas nasal pressure cannula amplitude/unit change in pneumotachograph amplitude was almost four times that for oral. Increasing oral orifice area from 0.33 cm(2) to 2.15 cm(2) increased oral thermocouple amplitude/unit change in pneumotachograph amplitude by ∼ 58% but decreased pressure cannula amplitude/unit change in pneumotachograph amplitude by 49%. For pneumotachograph amplitudes up to 1 L s(-1), alterations in inspiratory/expiratory ratios or total respiratory time did not affect the sensitivity of either nasal or oral pressure cannulae or the nasal thermocouple, but the oral thermocouple sensitivity was influenced by respiratory cycle time. Different nasal and oral responses influence the ability of these systems to quantitatively assess nasal and oral airflow and oro-nasal airflow partitioning.
Crim, Courtney; Calverley, Peter M A; Anderson, Julie A; Holmes, Andrew P; Kilbride, Sally; Martinez, Fernando J; Brook, Robert D; Newby, David E; Yates, Julie C; Celli, Bartolomé R; Vestbo, Jørgen
2017-10-01
Pneumonia risk with inhaled corticosteroid use in chronic obstructive pulmonary disease (COPD) has not been thoroughly assessed in patients with moderate airflow limitation. To determine the incidence of pneumonia and risk factors in COPD patients with moderate airflow limitation who had, or were at high risk for cardiovascular disease. In the Study to Understand Mortality and MorbidITy in COPD (SUMMIT), 16,590 subjects with moderate airflow limitation (50% ≤ FEV 1 ≤ 70% predicted) and heightened cardiovascular risk were randomized double-blind 1:1:1:1 to inhaled once-daily vilanterol 25 μg (VI), fluticasone furoate 100 μg (FF), vilanterol 25 μg combined with 100 μg fluticasone furoate (FF/VI), or matched placebo. In a pre-specified analysis, we assessed investigator-reported adverse pneumonia events, and independently-adjudicated fatal events. The safety population comprised 16,568 subjects who actually received study medication. There were 1017 pneumonia events reported from 842 subjects. For placebo, FF, VI and FF/VI, reported pneumonia incidence was 5%, 5%, 4% and 6%, respectively. When adjusted for time on treatment, event rates were similar in the placebo, FF and FF/VI containing arms (3.84, 4.24 and 3.95/100 treatment years, respectively) but lower in the VI group (2.77/100 treatment years). Risk factors for pneumonia risk included: greater degree of airflow limitation (i.e. FEV 1 <60% predicted), prior exacerbation history, and BMI <25 kg/m 2 . In contrast to previous studies in patients with severe disease, increased pneumonia risk with inhaled corticosteroid use was not evident in COPD subjects with moderate airflow limitation and heightened cardiovascular risk. Copyright © 2017 Elsevier Ltd. All rights reserved.
Agodi, A; Auxilia, F; Barchitta, M; Cristina, M L; D'Alessandro, D; Mura, I; Nobile, M; Pasquarella, C
2015-07-01
Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. To evaluate airborne microbial contamination in OTs during hip and knee replacement surgery, and compare the findings with values recommended for joint replacement surgery. Air samplings were performed in 28 OTs supplied with unidirectional, turbulent and mixed airflow ventilation. Samples were collected using passive sampling to determine the index of microbial air contamination (IMA). Active sampling was also performed in some of the OTs. The average number of people in the OT and the number of door openings during the sampling period were recorded. In total, 1228 elective prosthesis procedures (60.1% hip and 39.9% knee) were included in this study. Of passive samplings performed during surgical activity in unidirectional airflow ventilation OTs (U-OTs) and mixed airflow OTs (M-OTs), 58.9% and 87.6% had IMA values >2, respectively. Of samplings performed during surgical activity in turbulent airflow OTs (T-OTs) and in turbulent airflow OTs with the surgical team wearing Steri-Shield Turbo Helmets (TH-OTs), 8.6% and 60% had IMA values ≤ 2, respectively. Positive correlation was found between IMA values and the number of people in the OT and the number of door openings (P < 0.001). In addition, correlation was found between active and passive sampling (P < 0.001). These findings challenge the belief that unidirectional systems always provide acceptable airborne bacterial counts. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Individuality of breathing during volitional moderate hyperventilation.
Besleaga, Tudor; Blum, Michaël; Briot, Raphaël; Vovc, Victor; Moldovanu, Ion; Calabrese, Pascale
2016-01-01
The aim of this study is to investigate the individuality of airflow shapes during volitional hyperventilation. Ventilation was recorded on 18 healthy subjects following two protocols: (1) spontaneous breathing (SP1) followed by a volitional hyperventilation at each subject's spontaneous (HVSP) breathing rate, (2) spontaneous breathing (SP2) followed by hyperventilation at 20/min (HV20). HVSP and HV20 were performed at the same level of hypocapnia: end tidal CO2 (FETCO2) was maintained at 1% below the spontaneous level. At each breath, the tidal volume (VT), the breath (TTOT), the inspiratory (TI) and expiratory durations, the minute ventilation, VT/TI, TI/TTOT and the airflow shape were quantified by harmonic analysis. Under different conditions of breathing, we test if the airflow profiles of the same individual are more similar than airflow profiles between individuals. Minute ventilation was not significantly different between SP1 (6.71 ± 1.64 l·min(-1)) and SP2 (6.57 ± 1.31 l·min(-1)) nor between HVSP (15.88 ± 4.92 l·min(-1)) and HV20 (15.87 ± 4.16 l·min(-1)). Similar results were obtained for FETCO2 between SP1 (5.06 ± 0.54 %) and SP2 (5.00 ± 0.51%), and HVSP (4.07 ± 0.51%) and HV20 (3.88 ± 0.42%). Only TI/TTOT remained unchanged in all four conditions. Airflow shapes were similar when comparing SP1-SP2, HVSP-HV20, and SP1-HVSP but not similar when comparing SP2-HV20. These results suggest the existence of an individuality of airflow shape during volitional hyperventilation. We conclude that volitional ventilation alike automatic breathing follows inherent properties of the ventilatory system. Registered by Pascale Calabrese on ClinicalTrials.gov, # NCT01881945.
Brehm, Susan Baker; Weinrich, Barbara D; Sprouse, Dana C; May, Shelley K; Hughes, Michael R
2012-11-01
The purpose of this study was to determine the effect of task type on fundamental frequency (F(0)) and the short-term repeatability of average airflow values in preschool/kindergarten-age children. Prospective, experimental. Thirty healthy children (age 4.0-5.11 years) were included in this study. Participants completed three tasks (sustained vowel, counting, and storytelling) used to elicit measurements of F(0). With a 10-minute interval, participants also completed two trials of sustained /a/ at a comfortable pitch and loudness level for the measurement of average airflow rate. F(0) and intensity of the vowel production were recorded for both trials. A repeated measures analysis of variance revealed a significant main effect for task type elicitation on F(0) values (P=0.0003). A significant difference between elicitation tasks for F(0) was observed in the comparison of the counting and storytelling task (P<0.0001). A paired t test revealed no significant difference in average airflow rate across two trials (P=0.872). The change in F(0) and intensity was measured across the trials, and separate analyses of covariance revealed that these changes did not significantly influence average airflow values, (P=0.809) and (P=0.365), respectively. The results of this study demonstrated that F(0) may be influenced by task type in young children. Average airflow values appear to be stable over a short time period. This information is important in determining methods of evaluation and the reliability of instrumental measures in young children with voice disorders. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Matsumoto, Koichiro; Seki, Nanae; Fukuyama, Satoru; Moriwaki, Atsushi; Kan-o, Keiko; Matsunaga, Yuko; Noda, Naotaka; Yoshida, Makoto; Koto, Hiroshi; Takata, Shohei; Nakanishi, Yoichi; Kiyohara, Yutaka; Inoue, Hiromasa
2015-01-01
Elucidating the prevalence of asthma and chronic obstructive pulmonary disease (COPD) is important for designing a public health strategy. Recent studies have discriminated a phenotype of COPD with variable airflow limitation (COPD-VAL) associated with asthma-COPD overlap syndrome. Its prevalence remains uncertain. The age and occupational distributions in the town of Hisayama and in Japan are nearly identical. Each disease's prevalence was estimated for the town's residents. In 2008, town residents (≥ 40 years) were solicited to participate in a health checkup. Individuals with abnormal spirometry (forced expiratory volume in 1s/forced vital capacity [FEV1/FVC]<70% and/or %FVC<80%) were recommended for further evaluations. Two pulmonologists in a blinded fashion reviewed their medical records, including bronchodilator reversibility. Individuals with airflow limitation were classified as having asthma, COPD, COPD-VAL, or other diseases. The prevalence of each disease was then estimated. A total of 2100 residents (43.4% of residents in the age group) completed spirometry. In 455 residents with abnormal spirometry, 190 residents had further evaluations, and the medical records of 174 residents were reviewed. The prevalence of asthma with airflow limitation, COPD, and COPD-VAL, were 2.0%, 8.4%, and 0.9%, respectively. The prevalence of COPD and COPD-VAL were higher in men and smokers than in women and never-smokers. The prevalence of COPD, but not COPD-VAL or asthma, increased with age. The prevalence of asthma with airflow limitation, COPD, and COPD-VAL were estimated in a population of residents (≥ 40 years) in Hisayama. Copyright © 2014 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
Correlation of Nasal Mucosal Temperature With Subjective Nasal Patency in Healthy Individuals
Bailey, Ryan S.; Casey, Kevin P.; Pawar, Sachin S.; Garcia, Guilherme J. M.
2016-01-01
Importance Historically, otolaryngologists have focused on nasal resistance to airflow and minimum airspace cross-sectional area as objective measures of nasal obstruction using methods such as rhinomanometry and acoustic rhinometry. However, subjective sensation of nasal patency may be more associated with activation of cold receptors by inspired air than with respiratory effort. Objective To investigate whether subjective nasal patency correlates with nasal mucosal temperature in healthy subjects. Design, Setting, and Participants Twenty-two healthy adults were recruited for this study. Subjects first completed the Nasal Obstruction Symptom Evaluation (NOSE) and a unilateral visual analog scale (VAS) to quantify subjective nasal patency. A miniaturized thermocouple sensor was then used to record nasal mucosal temperature bilaterally in two locations along the nasal septum: at the vestibule and across from the inferior turbinate head. Results The range of temperature oscillations during the breathing cycle, defined as the difference between end-expiratory and end-inspiratory temperatures, was greater during deep breaths (ΔTexp-insp = 6.2 ± 2.6°C) than during resting breathing (ΔTexp-insp = 4.2 ± 2.3°C) in both locations (p < 10−13). Mucosal temperature measured at the right vestibule had a statistically significant correlation with both right-side VAS score (Pearson r = −0.55, p=0.0076) and NOSE score (Pearson r = −0.47, p=0.028). No other statistically significant correlations were found between mucosal temperature and subjective nasal patency scores. Nasal mucosal temperature was lower in the first cavity to be measured, which was the right cavity in all subjects. Conclusions and Relevance The greater mucosal temperature oscillations during deep breathing is consistent with the common experience that airflow sensation is enhanced during deep breaths, thus supporting the hypothesis that mucosal cooling plays a central role in nasal airflow sensation. A possible correlation was found between subjective nasal patency scores and nasal mucosal temperature, but our results were inconsistent. The higher temperature in the left cavity suggests that the sensor irritated the nasal mucosa, affecting the correlation between patency scores and mucosal temperature. Future studies should consider non-contact temperature sensors to prevent mucosa irritation. PMID:27918749
Air temperature gradient in large industrial hall
NASA Astrophysics Data System (ADS)
Karpuk, Michał; Pełech, Aleksander; Przydróżny, Edward; Walaszczyk, Juliusz; Szczęśniak, Sylwia
2017-11-01
In the rooms with dominant sensible heat load, volume airflow depends on many factors incl. pre-established temperature difference between exhaust and supply airflow. As the temperature difference is getting higher, airflow volume drops down, consequently, the cost of AHU is reduced. In high industrial halls with air exhaust grids located under the ceiling additional temperature gradient above working zone should be taken into consideration. In this regard, experimental research of the vertical air temperature gradient in high industrial halls were carried out for the case of mixing ventilation system The paper presents the results of air temperature distribution measurements in high technological hall (mechanically ventilated) under significant sensible heat load conditions. The supply airflow was delivered to the hall with the help of the swirl diffusers while exhaust grids were located under the hall ceiling. Basing on the air temperature distribution measurements performed on the seven pre-established levels, air temperature gradient in the area between 2.0 and 7.0 m above the floor was calculated and analysed.
Energy Harvesting from Human Motion Using Footstep-Induced Airflow
NASA Astrophysics Data System (ADS)
Fu, H.; Xu, R.; Seto, K.; Yeatman, E. M.; Kim, S. G.
2015-12-01
This paper presents an unobtrusive in-shoe energy harvester converting foot-strike energy into electricity to power wearable or portable devices. An air-pumped turbine system is developed to address the issues of the limited vertical deformation of shoes and the low frequency of human motion that impede harvesting energy from this source. The air pump is employed to convert the vertical foot-strike motion into airflow. The generated airflow passes through the miniaturized wind turbine whose transduction is realized by an electromagnetic generator. Energy is extracted from the generator with a higher frequency than that of footsteps, boosting the output power of the device. The turbine casing is specifically designed to enable the device to operate continuously with airflow in both directions. A prototype was fabricated and then tested under different situations. A 6 mW peak power output was obtained with a 4.9 Ω load. The achievable power from this design was estimated theoretically for understanding and further improvement.
Cox, Jolene A; Beanland, Vanessa; Filtness, Ashleigh J
2017-10-03
The ability to detect changing visual information is a vital component of safe driving. In addition to detecting changing visual information, drivers must also interpret its relevance to safety. Environmental changes considered to have high safety relevance will likely demand greater attention and more timely responses than those considered to have lower safety relevance. The aim of this study was to explore factors that are likely to influence perceptions of risk and safety regarding changing visual information in the driving environment. Factors explored were the environment in which the change occurs (i.e., urban vs. rural), the type of object that changes, and the driver's age, experience, and risk sensitivity. Sixty-three licensed drivers aged 18-70 years completed a hazard rating task, which required them to rate the perceived hazardousness of changing specific elements within urban and rural driving environments. Three attributes of potential hazards were systematically manipulated: the environment (urban, rural); the type of object changed (road sign, car, motorcycle, pedestrian, traffic light, animal, tree); and its inherent safety risk (low risk, high risk). Inherent safety risk was manipulated by either varying the object's placement, on/near or away from the road, or altering an infrastructure element that would require a change to driver behavior. Participants also completed two driving-related risk perception tasks, rating their relative crash risk and perceived risk of aberrant driving behaviors. Driver age was not significantly associated with hazard ratings, but individual differences in perceived risk of aberrant driving behaviors predicted hazard ratings, suggesting that general driving-related risk sensitivity plays a strong role in safety perception. In both urban and rural scenes, there were significant associations between hazard ratings and inherent safety risk, with low-risk changes perceived as consistently less hazardous than high-risk impact changes; however, the effect was larger for urban environments. There were also effects of object type, with certain objects rated as consistently more safety relevant. In urban scenes, changes involving pedestrians were rated significantly more hazardous than all other objects, and in rural scenes, changes involving animals were rated as significantly more hazardous. Notably, hazard ratings were found to be higher in urban compared with rural driving environments, even when changes were matched between environments. This study demonstrates that drivers perceive rural roads as less risky than urban roads, even when similar scenarios occur in both environments. Age did not affect hazard ratings. Instead, the findings suggest that the assessment of risk posed by hazards is influenced more by individual differences in risk sensitivity. This highlights the need for driver education to account for appraisal of hazards' risk and relevance, in addition to hazard detection, when considering factors that promote road safety.
Multiple sites of exposure in an outbreak of ornithosis in workers at a poultry abattoir and farm.
Tiong, A; Vu, T; Counahan, M; Leydon, J; Tallis, G; Lambert, S
2007-10-01
Cases of ornithosis amongst workers on a rural duck abattoir and farm were notified from late 2003 to health authorities in Victoria, Australia. In May 2004 we conducted a serological survey to identify the extent of exposure to Chlamydophila psittaci amongst workers and a case control study to identify high-risk work areas for ornithosis-related pneumonia. Some workers in all occupational groups showed serological evidence of exposure, while those with pneumonia were more likely to have worked in the slaughtering area of the abattoir (adjusted odds ratio 16.7, 95% confidence interval 1.3-207). High exposure to blood and feathers from recently killed birds is likely to represent an occupational hazard to workers, but pneumonia did occur in workers without these exposures. We recommended respiratory protection for all abattoir workers and improvements to airflow and reduction of environmental contamination in high-risk work areas to prevent further cases.
Göhler, Daniel; Stintz, Michael; Hillemann, Lars; Vorbau, Manuel
2010-01-01
Nanoparticles are used in industrial and domestic applications to control customized product properties. But there are several uncertainties concerning possible hazard to health safety and environment. Hence, it is necessary to search for methods to analyze the particle release from typical application processes. Based on a survey of commercial sanding machines, the relevant sanding process parameters were employed for the design of a miniature sanding test setup in a particle-free environment for the quantification of the nanoparticle release into air from surface coatings. The released particles were moved by a defined airflow to a fast mobility particle sizer and other aerosol measurement equipment to enable the determination of released particle numbers additionally to the particle size distribution. First, results revealed a strong impact of the coating material on the swarf mass and the number of released particles. PMID:20696941
Does air gas aesthesiometry generate a true mechanical stimulus for corneal sensitivity measurement?
Nosch, Daniela S; Pult, Heiko; Albon, Julie; Purslow, Christine; Murphy, Paul J
2018-03-01
Belmonte Ocular Pain Meter (OPM) air jet aesthesiometry overcomes some of the limitations of the Cochet-Bonnet aesthesiometer. However, for true mechanical corneal sensitivity measurement, the airflow stimulus temperature of the aesthesiometer must equal ocular surface temperature (OST), to avoid additional response from temperature-sensitive nerves. The aim of this study was to determine: (A) the stimulus temperature inducing no or least change in OST; and (B) to evaluate if OST remains unchanged with different stimulus durations and airflow rates. A total of 14 subjects (mean age 25.14 ± 2.18 years; seven women) participated in this clinical cohort study: (A) OST was recorded using an infrared camera (FLIR A310) during the presentation of airflow stimuli, at five temperatures, ambient temperature (AT) +5°C, +10°C, +15°C, +20°C and +30°C, using the OPM aesthesiometer (duration three seconds; over a four millimetre distance; airflow rate 60 ml/min); and (B) OST measurements were repeated with two stimulus temperatures (AT +10°C and +15°C) while varying stimulus durations (three seconds and five seconds) and airflow rates (30, 60, 80 and 100 ml/min). Inclusion criteria were age <40 years, no contact lens wear, absence of ocular disease including dry eye, and no use of artificial tears. Repeated measures (analysis of variance) and appropriate post-hoc t-tests were applied. (A) Stimulus temperatures of AT +10°C and +15°C induced the least changes in OST (-0.20 ± 0.13°C and 0.08 ± 0.05°C). (B) OST changes were statistically significant with both stimulus temperatures and increased with increasing airflow rates (p < 0.001), and were more marked with stimulus temperature AT +10°C. A true mechanical threshold for corneal sensitivity cannot be established with the air stimulus of the Belmonte OPM because its air jet stimulus with mechanical setting is likely to have a thermal component. Appropriate stimulus selection for an air jet aesthesiometer must incorporate stimulus temperature control that can vary with stimulus duration and airflow rate. © 2017 Optometry Australia.
NASA Astrophysics Data System (ADS)
Taylor, Faith E.; Malamud, Bruce D.; Millington, James D. A.
2016-04-01
The configuration of infrastructure networks such as roads, drainage and power lines can both affect and be affected by natural hazards such as earthquakes, intense rain, wildfires and extreme temperatures. In this paper, we present and compare two methods to quantify urban topology on approximate scales of 0.0005 km2 to 10 km2 and create classifications of different 'urban textures' that relate to risk of natural hazard impact in an area. The methods we use focus on applicability in urban developing country settings, where access to high resolution and high quality data may be difficult. We use the city of Nairobi, Kenya to trial these methods. Nairobi has a population >3 million, and is a mix of informal settlements, residential and commercial development. The city and its immediate surroundings are subject to a variety of natural hazards such as floods, landslides, fires, drought, hail, heavy wind and extreme temperatures; all of these hazards can occur singly, but also have the potential for one to trigger another, thus providing a 'cascade' of hazards, or for two of the hazards to occur spatially and temporally near each other and interact. We use two measures of urban texture: (i) Street block textures, (ii) Google Earth land cover textures. Street block textures builds on the methodology of Louf and Barthelemy (2014) and uses Open Street Map data to analyse the shape, size, complexity and pattern of individual blocks of land created by fully enclosed loops of the major and minor road network of Nairobi. We find >4000 of these blocks ranging in size from approximately 0.0005 km2 to 10 km2, with approximately 5 classifications of urban texture. Google Earth land cover texture is a visual classification of homogeneous parcels of land performed in Google Earth using high-resolution airborne imagery and a qualitative criteria for each land cover type. Using the Google Earth land cover texture method, we identify >40 'urban textures' based on visual characteristics such as colour, texture, shadow and setting and have created a clear criteria for classifying an area based on its visual characteristics. These two methods for classifying urban texture in Nairobi are compared in a GIS and in the field to investigate whether there is a link between the visual appearance of an area and its network topology. From these urban textures, we may start to identify areas where (a) urban texture types may indicate a relative propensity to certain hazards and their interactions and (b) urban texture types that may increase or decrease the impact of a hazard that occurs in that area.
Resistance to airflow through bedding materials used in infancy.
Hatch, D J; Helms, P; Matthew, D J; Skinner, D
1982-01-01
Various bedding materials used in infancy, including duvets (or continental quilts), were tested for airflow using the British Standards Institution tests for pillows or fabrics. Resistance was also measured when the items were placed on a dummy infant face. Measurements were made on washed and unwashed garments, which were tested both dry and wet. Results suggest that all the bedding materials tested are safe for use even in the newborn period. The duvets produced slightly lower resistance to breathing than conventional blankets and sheets. In view of the wide variety of infant bedding fabrics it seems desirable for standard airflow performance requirements to be introduced. PMID:7092309
Two-dimensional airflow modeling underpredicts the wind velocity over dunes
Michelsen, Britt; Strobl, Severin; Parteli, Eric J. R.; Pöschel, Thorsten
2015-01-01
We investigate the average turbulent wind field over a barchan dune by means of Computational Fluid Dynamics. We find that the fractional speed-up ratio of the wind velocity over the three-dimensional barchan shape differs from the one obtained from two-dimensional calculations of the airflow over the longitudinal cut along the dune’s symmetry axis — that is, over the equivalent transverse dune of same size. This finding suggests that the modeling of the airflow over the central slice of barchan dunes is insufficient for the purpose of the quantitative description of barchan dune dynamics as three-dimensional flow effects cannot be neglected. PMID:26572966
49 CFR 173.37 - Hazardous Materials in Flexible Bulk Containers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... an external visual inspection by the person filling the Flexible Bulk Container to ensure: (1) The... transported in cargo transport units when offered for transportation by vessel. (7) Flexible Bulk Containers... 49 Transportation 2 2013-10-01 2013-10-01 false Hazardous Materials in Flexible Bulk Containers...
49 CFR 173.37 - Hazardous Materials in Flexible Bulk Containers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... an external visual inspection by the person filling the Flexible Bulk Container to ensure: (1) The... transported in cargo transport units when offered for transportation by vessel. (7) Flexible Bulk Containers... 49 Transportation 2 2014-10-01 2014-10-01 false Hazardous Materials in Flexible Bulk Containers...
21 CFR 874.3900 - Nasal dilator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... nasal airflow. The device decreases airway resistance and increases nasal airflow. The external nasal...
21 CFR 874.3900 - Nasal dilator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasal dilator. 874.3900 Section 874.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... nasal airflow. The device decreases airway resistance and increases nasal airflow. The external nasal...
NASA Astrophysics Data System (ADS)
Bian, Yixiang; Liu, Rongrong; Hui, Shen
2016-09-01
We fabricated a sensitive air flow detector that mimic the sensing mechanism found at the tail of some insects. [see Y. Yang, A. Klein, H. Bleckmann and C. Liu, Appl. Phys. Lett. 99(2) (2011); J. J. Heys, T. Gedeon, B. C. Knott and Y. Kim, J. Biomech. 41(5), 977 (2008); J. Tao and X. Yu, Smart Mat. Struct. 21(11) (2012)]. Our bionic airflow sensor uses a polyvinylidene difluoride (PVDF) microfiber with a molybdenum core which we produced with the hot extrusion tensile method. The surface of the fiber is partially coated with conductive silver adhesive that serve as surface electrodes. A third electrode, the metal core is used to polarize polyvinylidene difluoride (PVDF) under the surface electrodes. The cantilever beam structure of the prepared symmetric electrodes of metal core piezoelectric fiber (SMPF) is used as the artificial hair airflow sensor. The surface electrodes are used to measure output voltage. Our theoretical and experimental results show that the SMPF responds fast to air flow changes, the output charge has an exponential correlation with airflow velocity and a cosine relation with the direction of airflow. Our bionic airflow sensor with directional sensing ability can also measure air flow amplitude. [see H. Droogendijk, R. G. P. Sanders and G. J. M. Krijnen, New J. Phys. 15 (2013)]. By using two surface electrodes, our sensing circuit further improves sensitivity.
Tajber, L; Corrigan, O I; Healy, A M
2009-02-09
The aim of this study was to investigate the effect of changing spray drying parameters on the production of a budesonide/formoterol fumarate 100:6 (w/w) composite. The systems were spray dried as solutions from 95% ethanol/5% water (v/v) using a Büchi 191-Mini Spray Dryer. A 2(5-1) factorial design study was undertaken to assess the consequence of altering spray drying processing variables on particle characteristics. The processing parameters that were studied were inlet temperature, spray drier airflow rate, pump rate, aspirator setting and feed concentration. Each batch of the resulting powder was characterised in terms of thermal and micromeritic properties as well as an in vitro deposition by twin impinger analysis. Overall, the parameter that had the greatest influence on each response investigated was production yield - airflow (higher airflow giving greater yields), median particle size - airflow (higher airflow giving smaller particle sizes) and Carr's compressibility index - feed concentration (lower feed concentration giving smaller Carr's indices). A six- to seven-fold difference in respirable fraction can be observed by changing the spray drying process parameters. The co-spray dried composite system which displayed best in vitro deposition characteristics, showed a 2.6-fold increase in respirable fraction in the twin impinger experiments and better dose uniformity compared with the physical mix of micronised powders.
Detection of Mouse Cough Based on Sound Monitoring and Respiratory Airflow Waveforms
Chen, Liyan; Lai, Kefang; Lomask, Joseph Mark; Jiang, Bert; Zhong, Nanshan
2013-01-01
Detection for cough in mice has never yielded clearly audible sounds, so there is still a great deal of debates as to whether mice can cough in response to tussive stimuli. Here we introduce an approach for detection of mouse cough based on sound monitoring and airflow signals. 40 Female BALB/c mice were pretreated with normal saline, codeine, capasazepine or desensitized with capsaicin. Single mouse was put in a plethysmograph, exposed to aerosolized 100 µmol/L capsaicin for 3 min, followed by continuous observation for 3 min. Airflow signals of total 6 min were recorded and analyzed to detect coughs. Simultaneously, mouse cough sounds were sensed by a mini-microphone, monitored manually by an operator. When manual and automatic detection coincided, the cough was positively identified. Sound and sound waveforms were also recorded and filtered for further analysis. Body movements were observed by operator. Manual versus automated counts were compared. Seven types of airflow signals were identified by integrating manual and automated monitoring. Observation of mouse movements and analysis of sound waveforms alone did not produce meaningful data. Mouse cough numbers decreased significantly after all above drugs treatment. The Bland-Altman and consistency analysis between automatic and manual counts was 0.968 and 0.956. The study suggests that the mouse is able to present with cough, which could be detected by sound monitoring and respiratory airflow waveform changes. PMID:23555643
NASA Astrophysics Data System (ADS)
Turney, C. S. M.; Wilmshurst, J. M.; Jones, R. T.; Wood, J. R.; Palmer, J. G.; Hogg, A. G.; Fenwick, P.; Crowley, S. F.; Privat, K.; Thomas, Z.
2017-03-01
Late-twentieth century changes in the intensity and migration of Southern Hemisphere westerly winds have been implicated in spatially complex variability in atmospheric and ocean circulation, and ice-sheet dynamics, across the mid- to high-latitudes. A major uncertainty, however, is whether present day hemispheric-wide symmetrical airflow is representative of past behaviour. Here we report a multi-proxy study from Stewart Island and southern Fiordland, New Zealand (46-47°S) reconstructing Holocene changes at the northern limit of westerly airflow. Increased minerogenic input and a pronounced shift in cool-loving vegetation around 5500 years ago is consistent with the establishment of westerly airflow at this latitude in the southwest Pacific. In marked contrast, stronger winds are reported further south over the subantarctic Auckland (50°S) and Campbell (52°S) Islands from 8000 years ago. Intriguingly, reconstructions from the east Pacific suggest a weakening of core westerly airflow after 8500 years ago, but an expansion along the northern limits sometime after 5500 years ago. Our results suggest similar atmospheric circulation changes have been experienced in the Pacific since 5500 years ago, but indicate an expanded network of sites is needed to comprehensively test the driver(s) and impact(s) of Holocene mid-latitude westerly winds across the Southern Hemisphere.
Zhou, L; Goodman, G; Martikainen, A
2013-01-01
Continuous airflow monitoring can improve the safety of the underground work force by ensuring the uninterrupted and controlled distribution of mine ventilation to all working areas. Air velocity measurements vary significantly and can change rapidly depending on the exact measurement location and, in particular, due to the presence of obstructions in the air stream. Air velocity must be measured at locations away from obstructions to avoid the vortices and eddies that can produce inaccurate readings. Further, an uninterrupted measurement path cannot always be guaranteed when using continuous airflow monitors due to the presence of nearby equipment, personnel, roof falls and rib rolls. Effective use of these devices requires selection of a minimum distance from an obstacle, such that an air velocity measurement can be made but not affected by the presence of that obstacle. This paper investigates the impacts of an obstruction on the behavior of downstream airflow using a numerical CFD model calibrated with experimental test results from underground testing. Factors including entry size, obstruction size and the inlet or incident velocity are examined for their effects on the distributions of airflow around an obstruction. A relationship is developed between the minimum measurement distance and the hydraulic diameters of the entry and the obstruction. A final analysis considers the impacts of continuous monitor location on the accuracy of velocity measurements and on the application of minimum measurement distance guidelines.
Zhou, L.; Goodman, G.; Martikainen, A.
2015-01-01
Continuous airflow monitoring can improve the safety of the underground work force by ensuring the uninterrupted and controlled distribution of mine ventilation to all working areas. Air velocity measurements vary significantly and can change rapidly depending on the exact measurement location and, in particular, due to the presence of obstructions in the air stream. Air velocity must be measured at locations away from obstructions to avoid the vortices and eddies that can produce inaccurate readings. Further, an uninterrupted measurement path cannot always be guaranteed when using continuous airflow monitors due to the presence of nearby equipment, personnel, roof falls and rib rolls. Effective use of these devices requires selection of a minimum distance from an obstacle, such that an air velocity measurement can be made but not affected by the presence of that obstacle. This paper investigates the impacts of an obstruction on the behavior of downstream airflow using a numerical CFD model calibrated with experimental test results from underground testing. Factors including entry size, obstruction size and the inlet or incident velocity are examined for their effects on the distributions of airflow around an obstruction. A relationship is developed between the minimum measurement distance and the hydraulic diameters of the entry and the obstruction. A final analysis considers the impacts of continuous monitor location on the accuracy of velocity measurements and on the application of minimum measurement distance guidelines. PMID:26388684
Bacterial burden in the operating room: impact of airflow systems.
Hirsch, Tobias; Hubert, Helmine; Fischer, Sebastian; Lahmer, Armin; Lehnhardt, Marcus; Steinau, Hans-Ulrich; Steinstraesser, Lars; Seipp, Hans-Martin
2012-09-01
Wound infections present one of the most prevalent and frequent complications associated with surgical procedures. This study analyzes the impact of currently used ventilation systems in the operating room to reduce bacterial contamination during surgical procedures. Four ventilation systems (window-based ventilation, supported air nozzle canopy, low-turbulence displacement airflow, and low-turbulence displacement airflow with flow stabilizer) were analyzed. Two hundred seventy-seven surgical procedures in 6 operating rooms of 5 different hospitals were analyzed for this study. Window-based ventilation showed the highest intraoperative contamination (13.3 colony-forming units [CFU]/h) followed by supported air nozzle canopy (6.4 CFU/h; P = .001 vs window-based ventilation) and low-turbulence displacement airflow (3.4 and 0.8 CFU/h; P < .001 vs window-based ventilation and supported air nozzle canopy). The highest protection was provided by the low-turbulence displacement airflow with flow stabilizer (0.7 CFU/h), which showed a highly significant difference compared with the best supported air nozzle canopy theatre (3.9 CFU/h; P < .001). Furthermore, this system showed no increase of contamination in prolonged durations of surgical procedures. This study shows that intraoperative contamination can be significantly reduced by the use of adequate ventilation systems. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Optical intensity scintillation in the simulated atmospherical environment
NASA Astrophysics Data System (ADS)
Hajek, Lukas; Latal, Jan; Vanderka, Ales; Vitasek, Jan; Bojko, Marian; Bednarek, Lukas; Vasinek, Vladimir
2016-09-01
There are several parameters of the atmospheric environment which have an effect on the optical wireless connection. Effects like fog, snow or rain are ones of the effects which appears tendentiously and which are bound by season, geographic location, etc. One of the effects that appear with various intensity for the whole time is airflow. The airflow changes the local refractive index of the air and areas with lower or higher refractive index form. The light going through these areas refracts and due to the optical intensity scintillates on the detector of the receiver. The airflow forms on the basis of two effects in the atmosphere. The first is wind cut and flowing over barriers. The other is thermal flow when warm air rises to the higher layers of the atmosphere. The heart of this article is creation such an environment that will form airflow and the refractive index will scintillate. For the experiment, we used special laboratory box with high-speed ventilators and heating units to simulate atmospheric turbulence. We monitor the impact of ventilator arrangement and air temperature on the scintillation of the gas laser with wavelength 633 nm/15 mW. In the experiment, there is watched the difference in behavior between real measurement and flow simulation with the same peripheral conditions of the airflow in the area of 500 x 500 cm.
Experimental and Computational Investigation of Triple-rotating Blades in a Mower Deck
NASA Astrophysics Data System (ADS)
Chon, Woochong; Amano, Ryoichi S.
Experimental and computational studies were performed on the 1.27m wide three-spindle lawn mower deck with side discharge arrangement. Laser Doppler Velocimetry was used to measure the air velocity at 12 different sections under the mower deck. The high-speed video camera test provided valuable visual evidence of airflow and grass discharge patterns. The strain gages were attached at several predetermined locations of the mower blades to measure the strain. In computational fluid dynamics work, computer based analytical studies were performed. During this phase of work, two different trials were attempted. First, two-dimensional blade shapes at several arbitrary radial sections were selected for flow computations around the blade model. Finally, a three-dimensional full deck model was developed and compared with the experimental results.
WASTE HANDLING BUILDING VENTILATION SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
P.A. Kumar
2000-06-21
The Waste Handling Building Ventilation System provides heating, ventilation, and air conditioning (HVAC) for the contaminated, potentially contaminated, and uncontaminated areas of the Monitored Geologic Repository's (MGR) Waste Handling Building (WHB). In the uncontaminated areas, the non-confinement area ventilation system maintains the proper environmental conditions for equipment operation and personnel comfort. In the contaminated and potentially contaminated areas, in addition to maintaining the proper environmental conditions for equipment operation and personnel comfort, the contamination confinement area ventilation system directs potentially contaminated air away from personnel in the WHB and confines the contamination within high-efficiency particulate air (HEPA) filtration units. Themore » contamination confinement areas ventilation system creates airflow paths and pressure zones to minimize the potential for spreading contamination within the building. The contamination confinement ventilation system also protects the environment and the public by limiting airborne releases of radioactive or other hazardous contaminants from the WHB. The Waste Handling Building Ventilation System is designed to perform its safety functions under accident conditions and other Design Basis Events (DBEs) (such as earthquakes, tornadoes, fires, and loss of the primary electric power). Additional system design features (such as compartmentalization with independent subsystems) limit the potential for cross-contamination within the WHB. The system provides status of important system parameters and equipment operation, and provides audible and/or visual indication of off-normal conditions and equipment failures. The Waste Handling Building Ventilation System confines the radioactive and hazardous material within the building such that the release rates comply with regulatory limits. The system design, operations, and maintenance activities incorporate ALARA (as low as is reasonably achievable) principles to maintain personnel radiation doses to all occupational workers below regulatory limits and as low as is reasonably achievable. The Waste Handling Building Ventilation System interfaces with the Waste Handling Building System by being located within the WHB and by maintaining specific pressures, temperatures, and humidity within the building. The system also depends on the WHB for water supply. The system interfaces with the Site Radiological Monitoring System for continuous monitoring of the exhaust air; the Waste Handling Building Fire Protection System for detection of fire and smoke; the Waste Handling Building Electrical System for normal, emergency, and standby power; and the Monitored Geologic Repository Operations Monitoring and Control System for monitoring and control of the system.« less
The Environmental Technology Verification report discusses the technology and performance of the AFP30 air filter for dust and bioaerosol filtration manufactured by Airflow Products. The pressure drop across the filter was 62 Pa clean and 247 Pa dust loaded. The filtration effici...
Newsome, R; Tran, N; Paoli, G M; Jaykus, L A; Tompkin, B; Miliotis, M; Ruthman, T; Hartnett, E; Busta, F F; Petersen, B; Shank, F; McEntire, J; Hotchkiss, J; Wagner, M; Schaffner, D W
2009-03-01
Through a cooperative agreement with the U.S. Food and Drug Administration, the Institute of Food Technologists developed a risk-ranking framework prototype to enable comparison of microbiological and chemical hazards in foods and to assist policy makers, risk managers, risk analysts, and others in determining the relative public health impact of specific hazard-food combinations. The prototype is a bottom-up system based on assumptions that incorporate expert opinion/insight with a number of exposure and hazard-related risk criteria variables, which are propagated forward with food intake data to produce risk-ranking determinations. The prototype produces a semi-quantitative comparative assessment of food safety hazards and the impacts of hazard control measures. For a specific hazard-food combination the prototype can produce a single metric: a final risk value expressed as annual pseudo-disability adjusted life years (pDALY). The pDALY is a harmonization of the very different dose-response relationships observed for chemicals and microbes. The prototype was developed on 2 platforms, a web-based user interface and an Analytica(R) model (Lumina Decision Systems, Los Gatos, Calif., U.S.A.). Comprising visual basic language, the web-based platform facilitates data input and allows use concurrently from multiple locations. The Analytica model facilitates visualization of the logic flow, interrelationship of input and output variables, and calculations/algorithms comprising the prototype. A variety of sortable risk-ranking reports and summary information can be generated for hazard-food pairs, showing hazard and dose-response assumptions and data, per capita consumption by population group, and annual p-DALY.
SOCIAL AND NON-SOCIAL HAZARD RESPONSE IN DRIVERS WITH AUTISM SPECTRUM DISORDER
Bishop, Haley Johnson; Biasini, Fred J.; Stavrinos, Despina
2017-01-01
Driving is a complex task that relies on manual, cognitive, visual and social skill. The social demands of driving may be challenging for individuals with Autism Spectrum Disorder (ASD) due to known social impairments. This study investigated how drivers with ASD respond to social (e.g., pedestrians) and non-social (e.g., vehicles) hazards in a driving simulator compared to typically developing drivers. Overall, participants responded faster to social hazards than non-social hazards. It was also found that drivers with typical development reacted faster to social hazards, while drivers with ASD showed no difference in reaction time to social versus non-social hazards. Future work should further investigate how social impairments in ASD may affect driving safety. PMID:28070791
The Video Display Terminal Health Hazard Debate.
ERIC Educational Resources Information Center
Clark, Carolyn A.
A study was conducted to identify the potential health hazards of visual display terminals for employees and then to develop a list of recommendations for improving the physical conditions of the workplace. Data were collected by questionnaires from 55 employees in 10 word processing departments in Topeka, Kansas. A majority of the employees…
Flow volume loops in patients with goiters.
Geraghty, J G; Coveney, E C; Kiernan, M; O'Higgins, N J
1992-01-01
Plain radiology is the standard means of assessing upper airway obstruction in patients with goiters. Flow volume loop curves will provide additional information, because they allow a quantitative assessment of airflow dynamics in the respiratory cycle. Fifty-one patients had flow volume loops performed before and after thyroidectomy. There was a significant increase in the maximum inspiratory flow rate (3.9 +/- 0.2 versus 4.9 +/- 0.2 L/second, p less than 0.01) after thyroidectomy. Eight of twelve patients with normal tracheal radiology had improved airflow dynamics in the postoperative period. The flow volume loop curve is a simple noninvasive means of assessing airflow dynamics in patients with goiters and may be superior to conventional radiology. PMID:1731653
A Comparative Study of Airflow and Odorant Deposition in the Mammalian Nasal Cavity
NASA Astrophysics Data System (ADS)
Richter, Joseph; Rumple, Christopher; Ranslow, Allison; Quigley, Andrew; Pang, Benison; Neuberger, Thomas; Krane, Michael; van Valkenburgh, Blaire; Craven, Brent
2013-11-01
The complex structure of the mammalian nasal cavity provides a tortuous airflow path and a large surface area for respiratory air conditioning, filtering of inspired contaminants, and olfaction. Due to the small and contorted structure of the nasal turbinals, nasal anatomy and function remains poorly understood in most mammals. Here, we utilize high-resolution MRI scans to reconstruct anatomically-accurate models of the mammalian nasal cavity. These data are used to compare the form and function of the mammalian nose. High-fidelity computational fluid dynamics (CFD) simulations of nasal airflow and odorant deposition are presented and used to compare olfactory function across species (primate, rodent, canine, feline, ungulate).
An experimental investigation of tobacco smoke pollution in cars
Sendzik, Taryn; Travers, Mark J.; Hyland, Andrew
2009-01-01
Introduction Tobacco smoke pollution (TSP) has been identified as a serious public health threat. Although the number of jurisdictions that prohibit smoking in public places has increased rapidly, just a few successful attempts have been made to pass similar laws prohibiting smoking in cars, where the cabin space may contribute to concentrated exposure. In particular, TSP constitutes a potentially serious health hazard to children because of prolonged exposure and their small size. Methods The present study investigated the levels of TSP in 18 cars via the measurement of fine respirable particles (<2.5 microns in diameter or PM2.5) under a variety of in vivo conditions. Car owners smoked a single cigarette in their cars in each of five controlled air-sampling conditions. Each condition varied on movement of the car, presence of air conditioning, open windows, and combinations of these airflow influences. Results Smoking just a single cigarette in a car generated extremely high average levels of PM2.5: more than 3,800 μg/m3 in the condition with the least airflow (motionless car, windows closed). In moderate ventilation conditions (air conditioning or having the smoking driver hold the cigarette next to a half-open window), the average levels of PM2.5 were reduced but still at significantly high levels (air conditioning = 844 μg/m3; holding cigarette next to a half-open window = 223 μg/m3). Discussion This study demonstrates that TSP in cars reaches unhealthy levels, even under realistic ventilation conditions, lending support to efforts occurring across a growing number of jurisdictions to educate people and prohibit smoking in cars in the presence of children. PMID:19351785
Chan, Hiang Ping; Mukhopadhyay, Amartya; Chong, Pauline Lee Poh; Chin, Sally; Wong, Xue Yun; Ong, Venetia; Chan, Yiong Huak; Lim, Tow Keang; Phua, Jason
2017-01-01
COPD is a complex condition with a heavy burden of disease. Many multidimensional tools have been studied for their prognostic utility but none has been universally adopted as each has its own limitations. We hypothesize that a multidimensional tool examining four domains, health-related quality of life, disease severity, systemic effects of disease and patient factors, would better categorize and prognosticate these patients. We first evaluated 300 patients and found four factors that predicted mortality: BMI, airflow obstruction, St George's Respiratory Questionnaire and age (BOSA). A 10-point index (BOSA index) was constructed and prospectively validated in a cohort of 772 patients with all-cause mortality as the primary outcome. Patients were categorized into their respective BOSA quartile group based on their BOSA score. Multivariate survival analyses and receiver operator characteristic (ROC) curves were used to assess the BOSA index. Patients in BOSA Group 4 were at higher risk of death compared with their counterparts in Group 1 (hazard ratio (HR): 0.29, 95% CI: 0.16-0.51, P < 0.001) and Group 2 (HR: 0.53, 95% CI: 0.34-0.82, P = 0.005). Race and gender did not affect mortality. The area under the ROC curve for BOSA index was 0.690 ± 0.025 while that for Global Initiative for Chronic Obstructive Lung Disease (GOLD) 2011 was 0.641 ± 0.025 (P = 0.17). The BOSA index predicts mortality well and it has at least similar prognostic utility as GOLD 2011 in Asian patients. The BOSA index is a simple tool that does not require complex equipment or testing. It has the potential to be used widely. © 2016 Asian Pacific Society of Respirology.
ERIC Educational Resources Information Center
Weisberg, Michael
Many of the findings from ergonomics research on visual display workstations are relevant to the design of interactive learning stations. This 1993 paper briefly reviews ergonomics research on visual display workstations; specifically, (1) potential health hazards from electromagnetic radiation; (2) musculoskeletal disorders; (3)vision complaints;…
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...
USDA-ARS?s Scientific Manuscript database
In conjunction with an emission monitoring study, long-term airflow and environmental data were collected from four regional producer-owned and -operated mono-slope beef cattle facilities in the Northern Great Plains. The barns were oriented east-west, with approximate dimensions of an 8-m south wal...
Code of Federal Regulations, 2010 CFR
2010-10-01
... C supplied-air respirator, demand class; minimum requirements. (a) Inhalation resistance shall not... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE...
Test-Retest Reliability of Respiratory Resistance Measured with the Airflow Perturbation Device
ERIC Educational Resources Information Center
Gallena, Sally K.; Solomon, Nancy Pearl; Johnson, Arthur T.; Vossoughi, Jafar; Tian, Wei
2014-01-01
Purpose: In this study, the authors aimed to determine reliability of the airflow perturbation device (APD) to measure respiratory resistance within and across sessions during resting tidal (RTB) and postexercise breathing in healthy athletes, and during RTB across trials within a session in athletes with paradoxical vocal fold motion (PVFM)…
Code of Federal Regulations, 2012 CFR
2012-10-01
... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...
Code of Federal Regulations, 2013 CFR
2013-10-01
... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...
Code of Federal Regulations, 2014 CFR
2014-10-01
... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...
Code of Federal Regulations, 2010 CFR
2010-10-01
... respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... the facepiece shall not fall below atmospheric at inhalation airflows less than 115 liters (4 cubic...
Code of Federal Regulations, 2011 CFR
2011-10-01
... respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... the facepiece shall not fall below atmospheric at inhalation airflows less than 115 liters (4 cubic...
Zheng, Y.; Reed, W.R.; Potts, J.D.; Li, M.; Rider, J.P.
2018-01-01
The National Institute for Occupational Safety and Health (NIOSH) recently developed a series of validated models utilizing computational fluid dynamics (CFD) to study the effects of air-blocking shelves on airflows and respirable dust distribution associated with medium-sized surface blasthole drill shrouds as part of a dry dust collector system. Using validated CFD models, three different air-blocking shelves were included in the present study: a 15.2-cm (6-in.)-wide shelf; a 7.6-cm (3-in.)-wide shelf; and a 7.6-cm (3-in.)-wide shelf at four different shelf heights. In addition, the dust-collector-to-bailing airflow ratios of 1.75:1, 1.5:1, 1.25:1 and 1:1 were evaluated for the 15.2-cm (6-in.)-wide air-blocking shelf. This paper describes the methodology used to develop the CFD models. The effects of air-blocking shelves and dust collector-to-bailing airflow ratios were identified by the study, and problem regions were revealed under certain conditions.
A Hot-Polymer Fiber Fabry–Perot Interferometer Anemometer for Sensing Airflow
Lee, Cheng-Ling; Liu, Kai-Wen; Luo, Shi-Hong; Wu, Meng-Shan; Ma, Chao-Tsung
2017-01-01
This work proposes the first hot-polymer fiber Fabry–Perot interferometer (HPFFPI) anemometer for sensing airflow. The proposed HPFFPI is based on a single-mode fiber (SMF) endface that is attached to a UV-cured polymer to form an ultracompact fiber Fabry–Perot microcavity. The proposed polymer microcavity was heated using a low-cost chip resistor with a controllable dc driving power to achieve a desired polymer’s steady-state temperature (T) that exceeds the T of the surrounding environment. The polymer is highly sensitive to variations of T with high repeatability. When the hot polymer was cooled by the measured flowing air, the wavelength fringes of its optical spectra shifted. The HPFFPI anemometers have been experimentally evaluated for different cavity lengths and heating power values. Experimental results demonstrate that the proposed HPFFPI responses well in terms of airflow measurement. A high sensitivity of 1.139 nm/(m/s) and a good resolution of 0.0088 m/s over the 0~2.54 m/s range of airflow were achieved with a cavity length of 10 μm and a heating power of 0.402 W. PMID:28869510
The effects of a hot drink on nasal airflow and symptoms of common cold and flu.
Sanu, A; Eccles, R
2008-12-01
Hot drinks are a common treatment for common cold and flu but there are no studies reported in the scientific and clinical literature on this mode of treatment. This study investigated the effects of a hot fruit drink on objective and subjective measures of nasal airflow, and on subjective scores for common cold/flu symptoms in 30 subjects suffering from common cold/flu. The results demonstrate that the hot drink had no effect on objective measurement of nasal airflow but it did cause a significant improvement in subjective measures of nasal airflow. The hot drink provided immediate and sustained relief from symptoms of runny nose, cough, sneezing, sore throat, chilliness and tiredness, whereas the same drink at room temperature only provided relief from symptoms of runny nose, cough and sneezing. The effects of the drinks are discussed in terms of a placebo effect and physiological effects on salivation and airway secretions. In conclusion the results support the folklore that a hot tasty drink is a beneficial treatment for relief of most symptoms of common cold and flu.
Performance power evaluation of DC fan cooling system for PV panel by using ANSYS CFX
NASA Astrophysics Data System (ADS)
Syafiqah, Z.; Amin, N. A. M.; Irwan, Y. M.; Irwanto, M.; Leow, W. Z.; Amelia, A. R.
2017-09-01
A research has been conducted to find the optimum combination for DC fan air cooling system of photovoltaic (PV) panel. During normal operation of PV panel, it is estimated that only 15 % of solar radiation is converted into electrical energy. Meanwhile, the rest of the solar radiation is converted into heat energy which affects the performance of the PV panel. Therefore, the aim of this research is to investigate the performance power evaluation of DC fan cooling system for PV panel by using ANSYS CFX. The effect of airflow configuration of DC fan has been investigated. This is to analyze whether the airflow circulation of DC fan cause a change towards the maximum temperature of PV panel. Besides, the impact of varying number of DC fans attached at the back of PV panel is evaluated. The result of airflow circulation of DC fan has been discussed. Meanwhile, with the increment number of DC fans, the PV panel temperature drops significantly. As a conclusion, the optimum number of DC fans is two with the combination of inlet airflow.
NASA Technical Reports Server (NTRS)
Eberhart, C. J.; Snellgrove, L. M.; Zoladz, T. F.
2015-01-01
High intensity acoustic edgetones located upstream of the RS-25 Low Pressure Fuel Turbo Pump (LPFTP) were previously observed during Space Launch System (STS) airflow testing of a model Main Propulsion System (MPS) liquid hydrogen (LH2) feedline mated to a modified LPFTP. MPS hardware has been adapted to mitigate the problematic edgetones as part of the Space Launch System (SLS) program. A follow-on airflow test campaign has subjected the adapted hardware to tests mimicking STS-era airflow conditions, and this manuscript describes acoustic environment identification and characterization born from the latest test results. Fluid dynamics responsible for driving discrete excitations were well reproduced using legacy hardware. The modified design was found insensitive to high intensity edgetone-like discretes over the bandwidth of interest to SLS MPS unsteady environments. Rather, the natural acoustics of the test article were observed to respond in a narrowband-random/mixed discrete manner to broadband noise thought generated by the flow field. The intensity of these responses were several orders of magnitude reduced from those driven by edgetones.
Elasto-Aerodynamics-Driven Triboelectric Nanogenerator for Scavenging Air-Flow Energy.
Wang, Shuhua; Mu, Xiaojing; Wang, Xue; Gu, Alex Yuandong; Wang, Zhong Lin; Yang, Ya
2015-10-27
Efficient scavenging the kinetic energy from air-flow represents a promising approach for obtaining clean, sustainable electricity. Here, we report an elasto-aerodynamics-driven triboelectric nanogenerator (TENG) based on contact electrification. The reported TENG consists of a Kapton film with two Cu electrodes at each side, fixed on two ends in an acrylic fluid channel. The relationship between the TENG output power density and its fluid channel dimensions is systematically studied. TENG with a fluid channel size of 125 × 10 × 1.6 mm(3) delivers the maximum output power density of about 9 kW/m(3) under a loading resistance of 2.3 MΩ. Aero-elastic flutter effect explains the air-flow induced vibration of Kapton film well. The output power scales nearly linearly with parallel wiring of multiple TENGs. Connecting 10 TENGs in parallel gives an output power of 25 mW, which allows direct powering of a globe light. The TENG is also utilized to scavenge human breath induced air-flow energy to sustainably power a human body temperature sensor.
Laryngeal aerodynamics associated with oral contraceptive use: preliminary findings.
Gorham-Rowan, Mary; Fowler, Linda
2009-01-01
The purpose of this study was to examine possible differences in laryngeal aerodynamic measures during connected speech associated with oral contraceptive (OC) use. Eight women taking an OC, and eight others not taking an OC, participated in the study. Three trials of syllable /p/repetitions were obtained using a circumferentially vented face mask and small translabial tube. All participants were recorded on or near days 7 and 14 of their menstrual cycle. Subglottal pressure (P(SG)) and average airflow rates were obtained to determine laryngeal airway resistance. Glottal airflow measures of peak flow, minimum flow, alternating flow, as well as relative sound level (RSL) were obtained. P(SG) was obtained from the pressure peak associated with/p/. All airflow parameters and RSL were obtained from the vowel portion. No significant differences were found related to day of recording or OC use, indicating that OC use does not significantly affect laryngeal airflow regulation. The reader will better understand the effects of hormones and oral contraceptives on the female voice, as well as the specific changes in vocal function that may occur in conjunction with the use of oral contraceptives.
Three-Dimensional Numerical Simulation of Airflow in Nasopharynx.
NASA Astrophysics Data System (ADS)
Shome, Biswadip; Wang, Lian-Ping; Santare, Michael H.; Szeri, Andras Z.; Prasad, Ajay K.; Roberts, David
1996-11-01
A three-dimensional numerical simulation of airflow in nasopharynx (from the soft palate to the epiglottis) was conducted, using anatomically accurate model and finite element method, to study the influence of flow characteristics on obstructive sleep apnea (OSA). The results showed that the pressure drop in the nasopharynx is in the range 200-500 Pa. Ten different nasopharynx geometries resulting from three OSA treatment therapies (CPAP, mandibular repositioning devices, and surgery) were compared. The results confirmed that the airflow in the nasopharynx lies in the transitional flow regime and thus, a subtle change in the morphology caused by these treatment therapies has a large effect on the airflow. The onset of turbulence can cause as much as 40% of increase in pressure drop. For the transitional flow regime, the k-ɛ turbulence model was found to be the most appropriate model, when compared to the mixing length and the k-ω model, as it correctly reproduces the limiting laminar behavior. In addition, the pressure drop increased approximately as the square of the volumetric flow rate. Supported by NIH.
What can vortices tell us about vocal fold vibration and voice production.
Khosla, Sid; Murugappan, Shanmugam; Gutmark, Ephraim
2008-06-01
Much clinical research on laryngeal airflow has assumed that airflow is unidirectional. This review will summarize what additional knowledge can be obtained about vocal fold vibration and voice production by studying rotational motion, or vortices, in laryngeal airflow. Recent work suggests two types of vortices that may strongly contribute to voice quality. The first kind forms just above the vocal folds during glottal closing, and is formed by flow separation in the glottis; these flow separation vortices significantly contribute to rapid closing of the glottis, and hence, to producing loudness and high frequency harmonics in the acoustic spectrum. The second is a group of highly three-dimensional and coherent supraglottal vortices, which can produce sound by interaction with structures in the vocal tract. Present work is also described that suggests that certain laryngeal pathologies, such as asymmetric vocal fold tension, will significantly modify both types of vortices, with adverse impact on sound production: decreased rate of glottal closure, increased broadband noise, and a decreased signal to noise ratio. Recent research supports the hypothesis that glottal airflow contains certain vortical structures that significantly contribute to voice quality.
Comparing capacity coefficient and dual task assessment of visual multitasking workload
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blaha, Leslie M.
Capacity coefficient analysis could offer a theoretically grounded alternative approach to subjective measures and dual task assessment of cognitive workload. Workload capacity or workload efficiency is a human information processing modeling construct defined as the amount of information that can be processed by the visual cognitive system given a specified of amount of time. In this paper, I explore the relationship between capacity coefficient analysis of workload efficiency and dual task response time measures. To capture multitasking performance, I examine how the relatively simple assumptions underlying the capacity construct generalize beyond the single visual decision making tasks. The fundamental toolsmore » for measuring workload efficiency are the integrated hazard and reverse hazard functions of response times, which are defined by log transforms of the response time distribution. These functions are used in the capacity coefficient analysis to provide a functional assessment of the amount of work completed by the cognitive system over the entire range of response times. For the study of visual multitasking, capacity coefficient analysis enables a comparison of visual information throughput as the number of tasks increases from one to two to any number of simultaneous tasks. I illustrate the use of capacity coefficients for visual multitasking on sample data from dynamic multitasking in the modified Multi-attribute Task Battery.« less
Huisingh, Carrie; McGwin, Gerald; Owsley, Cynthia
2017-01-01
Background Many studies on vision and driving cessation have relied on measures of sensory function, which are insensitive to the higher order cognitive aspects of visual processing. The purpose of this study was to examine the association between traditional measures of visual sensory function and higher order visual processing skills with incident driving cessation in a population-based sample of older drivers. Methods Two thousand licensed drivers aged ≥70 were enrolled and followed-up for three years. Tests for central vision and visual processing were administered at baseline and included visual acuity, contrast sensitivity, sensitivity in the driving visual field, visual processing speed (Useful Field of View (UFOV) Subtest 2 and Trails B), and spatial ability measured by the Visual Closure Subtest of the Motor-free Visual Perception Test. Participants self-reported the month and year of driving cessation and provided a reason for cessation. Cox proportional hazards models were used to generate crude and adjusted hazard ratios with 95% confidence intervals between visual functioning characteristics and risk of driving cessation over a three-year period. Results During the study period, 164 participants stopped driving which corresponds to a cumulative incidence of 8.5%. Impaired contrast sensitivity, visual fields, visual processing speed (UFOVand Trails B), and spatial ability were significant risk factors for subsequent driving cessation after adjusting for age, gender, marital status, number of medical conditions, and miles driven. Visual acuity impairment was not associated with driving cessation. Medical problems (63%), specifically musculoskeletal and neurological problems, as well as vision problems (17%) were cited most frequently as the reason for driving cessation. Conclusion Assessment of cognitive and visual functioning can provide useful information about subsequent risk of driving cessation among older drivers. In addition, a variety of factors, not just vision, influenced the decision to stop driving and may be amenable to intervention. PMID:27353969
Variability among electronic cigarettes in the pressure drop, airflow rate, and aerosol production.
Williams, Monique; Talbot, Prue
2011-12-01
This study investigated the performance of electronic cigarettes (e-cigarettes), compared different models within a brand, compared identical copies of the same model within a brand, and examined performance using different protocols. Airflow rate required to generate aerosol, pressure drop across e-cigarettes, and aerosol density were examined using three different protocols. First 10 puff protocol: The airflow rate required to produce aerosol and aerosol density varied among brands, while pressure drop varied among brands and between the same model within a brand. Total air hole area correlated with pressure drop for some brands. Smoke-out protocol: E-cigarettes within a brand generally performed similarly when puffed to exhaustion; however, there was considerable variation between brands in pressure drop, airflow rate required to produce aerosol, and the total number of puffs produced. With this protocol, aerosol density varied significantly between puffs and gradually declined. CONSECUTIVE TRIAL PROTOCOL: Two copies of one model were subjected to 11 puffs in three consecutive trials with breaks between trials. One copy performed similarly in each trial, while the second copy of the same model produced little aerosol during the third trial. The different performance properties of the two units were attributed to the atomizers. There was significant variability between and within brands in the airflow rate required to produce aerosol, pressure drop, length of time cartridges lasted, and production of aerosol. Variation in performance properties within brands suggests a need for better quality control during e-cigarette manufacture.
Gregg, I
1977-01-01
The most common reason why asthma presents difficulties in management is the failure to treat it with drugs which are appropriate and taken in adequate dosage. An understanding of the pathophysiology and aetiology of asthma is essential if full advantage is to be taken of the wide range of drugs now available for treating it. Airflow obstruction due to bronchial muscle constriction is usually readily reversible by bronchodilators, whereas that due to the inflammatory component of asthma is refractory to the latter and can only be reversed by steroids. Refractory airflow obstruction is liable to be confused with irreversible obstruction which occurs in those patients whose asthma is complicated by chronic obstructive bronchitis or other lung disease. The choice between symptomatic, preventive and suppressive forms of treatment should be made only after a careful assessment has been carried out with objective measurement of airflow obstruction. The Wright peak flow meter is unsurpassed for this purpose. By its means it should be possible to estimate how much of a patient's airflow obstruction is readily reversible, how much is refractory and how much is irreversible. In general, the aim of treatment is to relieve airflow obstruction rather than to counteract supposed aetiological factors. Both doctor and patient must understand the purpose, limitations and possible dangers of any drug which is prescribed. Steroids are the only form of treatment which is effective in persistent refractory asthma. Prejudice against steroids has resulted in many patients being deprived of their benefit, but this situation may change with the recent introduction of steroid aerosols.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Zhao, Kai; Dalton, Pamela; Yang, Geoffery C; Scherer, Peter W
2006-02-01
Human sniffing behavior usually involves bouts of short, high flow rate inhalation (>300 ml/s through each nostril) with mostly turbulent airflow. This has often been characterized as a factor enabling higher amounts of odorant to deposit onto olfactory mucosa than for laminar airflow and thereby aid in olfactory detection. Using computational fluid dynamics human nasal cavity models, however, we found essentially no difference in predicted olfactory odorant flux (g/cm2 s) for turbulent versus laminar flow for total nasal flow rates between 300 and 1000 ml/s and for odorants of quite different mucosal solubility. This lack of difference was shown to be due to the much higher resistance to lateral odorant mass transport in the mucosal nasal airway wall than in the air phase. The simulation also revealed that the increase in airflow rate during sniffing can increase odorant uptake flux to the nasal/olfactory mucosa but lower the cumulative total uptake in the olfactory region when the inspired air/odorant volume was held fixed, which is consistent with the observation that sniff duration may be more important than sniff strength for optimizing olfactory detection. In contrast, in rats, sniffing involves high-frequency bouts of both inhalation and exhalation with laminar airflow. In rat nose odorant uptake simulations, it was observed that odorant deposition was highly dependent on solubility and correlated with the locations of different types of receptors.
Estimating subglottal pressure via airflow interruption with auditory masking.
Hoffman, Matthew R; Jiang, Jack J
2009-11-01
Current noninvasive measurement of subglottal pressure using airflow interruption often produces inconsistent results due to the elicitation of audio-laryngeal reflexes. Auditory feedback could be considered as a means of ensuring measurement accuracy and precision. The purpose of this study was to determine if auditory masking could be used with the airflow interruption system to improve intrasubject consistency. A prerecorded sample of subject phonation was played on a loop over headphones during the trials with auditory masking. This provided subjects with a target pitch and blocked out distracting ambient noise created by the airflow interrupter. Subglottal pressure was noninvasively measured using the airflow interruption system. Thirty subjects, divided into two equal groups, performed 10 trials without auditory masking and 10 trials with auditory masking. Group one performed the normal trials first, followed by the trials with auditory masking. Group two performed the auditory masking trials first, followed by the normal trials. Intrasubject consistency was improved by adding auditory masking, resulting in a decrease in average intrasubject standard deviation from 0.93+/-0.51 to 0.47+/-0.22 cm H(2)O (P < 0.001). Auditory masking can be used effectively to combat audio-laryngeal reflexes and aid subjects in maintaining constant glottal configuration and frequency, thereby increasing intrasubject consistency when measuring subglottal pressure. By considering auditory feedback, a more reliable method of measurement was developed. This method could be used by clinicians, as reliable, immediately available values of subglottal pressure are useful in evaluating laryngeal health and monitoring treatment progress.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tian, Wei; Sevilla, Thomas Alonso; Zuo, Wangda
Historically, multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building's Heating, Ventilation, and Air-Conditioning (HVAC) systems. Thismore » paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simul ation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. This is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.« less
Alterations of the arginine metabolome in asthma.
Lara, Abigail; Khatri, Sumita B; Wang, Zeneng; Comhair, Suzy A A; Xu, Weiling; Dweik, Raed A; Bodine, Melanie; Levison, Bruce S; Hammel, Jeffrey; Bleecker, Eugene; Busse, William; Calhoun, William J; Castro, Mario; Chung, Kian Fan; Curran-Everett, Douglas; Gaston, Benjamin; Israel, Elliot; Jarjour, Nizar; Moore, Wendy; Peters, Stephen P; Teague, W Gerald; Wenzel, Sally; Hazen, Stanley L; Erzurum, Serpil C
2008-10-01
As the sole nitrogen donor in nitric oxide (NO) synthesis and key intermediate in the urea cycle, arginine and its metabolic pathways are integrally linked to cellular respiration, metabolism, and inflammation. We hypothesized that arginine (Arg) bioavailability would be associated with airflow abnormalities and inflammation in subjects with asthma, and would be informative for asthma severity. Arg bioavailability was assessed in subjects with severe and nonsevere asthma and healthy control subjects by determination of plasma Arg relative to its metabolic products, ornithine and citrulline, and relative to methylarginine inhibitors of NO synthases, and by serum arginase activity. Inflammatory parameters, including fraction of exhaled NO (Fe(NO)), IgE, skin test positivity to allergens, bronchoalveolar lavage, and blood eosinophils, were also evaluated. Subjects with asthma had greater Arg bioavailability, but also increased Arg catabolism compared with healthy control subjects, as evidenced by higher levels of Fe(NO) and serum arginase activity. However, Arg bioavailability was positively associated with Fe(NO) only in healthy control subjects; Arg bioavailability was unrelated to Fe(NO) or other inflammatory parameters in severe or nonsevere asthma. Inflammatory parameters were related to airflow obstruction and reactivity in nonsevere asthma, but not in severe asthma. Conversely, Arg bioavailability was related to airflow obstruction in severe asthma, but not in nonsevere asthma. Modeling confirmed that measures of Arg bioavailabilty predict airflow obstruction only in severe asthma. Unlike Fe(NO), Arg bioavailability is not a surrogate measure of inflammation; however, Arg bioavailability is strongly associated with airflow abnormalities in severe asthma.
Air trapping and airflow obstruction in newborn cystic fibrosis piglets.
Adam, Ryan J; Michalski, Andrew S; Bauer, Christian; Abou Alaiwa, Mahmoud H; Gross, Thomas J; Awadalla, Maged S; Bouzek, Drake C; Gansemer, Nicholas D; Taft, Peter J; Hoegger, Mark J; Diwakar, Amit; Ochs, Matthias; Reinhardt, Joseph M; Hoffman, Eric A; Beichel, Reinhard R; Meyerholz, David K; Stoltz, David A
2013-12-15
Air trapping and airflow obstruction are being increasingly identified in infants with cystic fibrosis. These findings are commonly attributed to airway infection, inflammation, and mucus buildup. To learn if air trapping and airflow obstruction are present before the onset of airway infection and inflammation in cystic fibrosis. On the day they are born, piglets with cystic fibrosis lack airway infection and inflammation. Therefore, we used newborn wild-type piglets and piglets with cystic fibrosis to assess air trapping, airway size, and lung volume with inspiratory and expiratory X-ray computed tomography scans. Micro-computed tomography scanning was used to assess more distal airway sizes. Airway resistance was determined with a mechanical ventilator. Mean linear intercept and alveolar surface area were determined using stereologic methods. On the day they were born, piglets with cystic fibrosis exhibited air trapping more frequently than wild-type piglets (75% vs. 12.5%, respectively). Moreover, newborn piglets with cystic fibrosis had increased airway resistance that was accompanied by luminal size reduction in the trachea, mainstem bronchi, and proximal airways. In contrast, mean linear intercept length, alveolar surface area, and lung volume were similar between both genotypes. The presence of air trapping, airflow obstruction, and airway size reduction in newborn piglets with cystic fibrosis before the onset of airway infection, inflammation, and mucus accumulation indicates that cystic fibrosis impacts airway development. Our findings suggest that early airflow obstruction and air trapping in infants with cystic fibrosis might, in part, be caused by congenital airway abnormalities.
Risk factors for persistent airflow limitation: Analysis of 306 patients with asthma.
Wang, Lingcheng; Gao, Shuncui; Zhu, Wei; Su, Jun
2014-01-01
Objectives : To determine the risk factors associated with persistent airflow limitation in patients with asthma. Method s: This study was designed and carried out in the department of respiratory medicine, fourth People's Hospital of Jinan City, Shandong province, China between Jan 2012 and Dec 2012. Three hundred and six asthma patients participating in the study were divided into persistent airflow limitation group (PAFL) and no persistent airflow limitation group (NPAFL). The patients participated in pulmonary function tests and sputum induction examination. The clinical data including age, gender, onset age, disease course, smoking history, family history, regular corticosteroid inhalation, hospitalization history and presence of atopy were collected. Results : In 306 patients, 128 (40.5%) were included in PAFL group and 178(59.5%) in NPAFL group. Multivariate analysis demonstrated smoking (≥10 pack-years; OR, 7.1; 95% CI, 1.8 to 31.2), longer asthma duration (≥ 20years) (OR, 6.3; 95% CI, 1.7 to 28.5), absence of regular corticosteroid inhalation (OR, 3.5; 95% CI, 1.1 to 14.5) and neutrophil in induced sputum≥65% (OR, 1.8; 95% CI, 1.0 to 2.8) were independent risk factors for PAFL. Conclusions : Smoking, longer asthma duration and increased neutrophil in induced sputum are risk factors for PAFL, while regular corticosteroid inhalation is protective factor. Smoking cessation and regular corticosteroid inhalation may play an important role in preventing the occurrence of persistent airflow limitation group (PAFL).
Correlation analysis of respiratory signals by using parallel coordinate plots.
Saatci, Esra
2018-01-01
The understanding of the bonds and the relationships between the respiratory signals, i.e. the airflow, the mouth pressure, the relative temperature and the relative humidity during breathing may provide the improvement on the measurement methods of respiratory mechanics and sensor designs or the exploration of the several possible applications in the analysis of respiratory disorders. Therefore, the main objective of this study was to propose a new combination of methods in order to determine the relationship between respiratory signals as a multidimensional data. In order to reveal the coupling between the processes two very different methods were used: the well-known statistical correlation analysis (i.e. Pearson's correlation and cross-correlation coefficient) and parallel coordinate plots (PCPs). Curve bundling with the number intersections for the correlation analysis, Least Mean Square Time Delay Estimator (LMS-TDE) for the point delay detection and visual metrics for the recognition of the visual structures were proposed and utilized in PCP. The number of intersections was increased when the correlation coefficient changed from high positive to high negative correlation between the respiratory signals, especially if whole breath was processed. LMS-TDE coefficients plotted in PCP indicated well-matched point delay results to the findings in the correlation analysis. Visual inspection of PCB by visual metrics showed range, dispersions, entropy comparisons and linear and sinusoidal-like relationships between the respiratory signals. It is demonstrated that the basic correlation analysis together with the parallel coordinate plots perceptually motivates the visual metrics in the display and thus can be considered as an aid to the user analysis by providing meaningful views of the data. Copyright © 2017 Elsevier B.V. All rights reserved.
Scoliosis associated with airflow obstruction due to endothoracic vertebral hump.
Ito, Kenyu; Kawakami, Noriaki; Miyasaka, Kazuyoshi; Tsuji, Taichi; Ohara, Tetsuya; Nohara, Ayato
2012-12-01
A retrospective clinical study of scoliosis-associated airflow obstruction due to endothoracic vertebral hump. The purpose of this study was to evaluate and present anatomical features of patients with scoliosis who showed airflow obstruction caused by endothoracic vertebral hump. It is well known that severe scoliosis causes airflow restriction due to thoracic cage deformity. There have been few reports of clinical data and anatomical features on scoliosis associated with airflow obstruction due to endothoracic vertebral hump. The subjects were 6 patients. The diagnoses were idiopathic scoliosis in 3 patients, symptomatic scoliosis in 2 patients, and thoracogenic scoliosis in 1 patient. The radiological outcome, comorbidities, pre- and postoperative respiratory function, and surgical complication were analyzed. Four patients had preoperative atelectasis on the convex side of the lower lobe and improved after the operations. All patients showed main thoracic curves and their apex was located at T7-T9. All patients had lordoscoliosis except 1, who demonstrated kyphosing scoliosis. The correction rate was 78% (62.8%-83.5%). Preoperative thoracic lordosis within the range of -5° to -47° was postoperatively corrected to a substantially normal kyphosis within the range of 9° to 24°. The average vital capacity, percent VC improved from 0.72 L (0.33-1.17 L) to 1.21 L (0.82-1.71 L) and 45.5% (37.3%- 50.8%) to 63.7% (41.0%-88.6%) relatively. Spine Penetration Index improved from 23% (18%-35%) to 16% (13%-19%). Endothoracic hump ratio improved from 1.34 (0.98-1.93) to 1.12 (0.86-1.28). Each patient with symptomatic scoliosis and thoracogenic scoliosis required relatively long periods of respiration management. Patients having lordoscoliosis with an apex located between T7 and T9 may develop airflow obstruction due to an endothoracic vertebral hump. Correction of lordoscoliosis through anterior and posterior approaches successfully improved endothoracic hump ratio and atelectasis in all patients.
van Dijk, Wouter; Tan, Wan; Li, Pei; Guo, Best; Li, Summer; Benedetti, Andrea; Bourbeau, Jean
2015-01-01
The way in which spirometry is interpreted can lead to misdiagnosis of chronic obstructive pulmonary disease (COPD) resulting in inappropriate treatment. We compared the clinical relevance of 2 criteria for defining a low ratio of forced expiratory volume in 1 second to forced vital capacity (FEV1/FVC): the fixed ratio and the lower limit of normal. We analyzed data from the cross-sectional phase of the population-based Canadian Cohort of Obstructive Lung Disease (CanCOLD) study. We determined associations of the spirometric criteria for airflow limitation with patient-reported adverse outcomes, including respiratory symptoms, disability, health status, exacerbations, and cardiovascular disease. Sensitivity analyses were used to explore the impact of age and severity of airflow limitation on these associations. We analyzed data from 4,882 patients aged 40 years and older. The prevalence of airflow limitation was 17% by fixed ratio and 11% by lower limit of normal. Patients classified as having airflow limitation by fixed ratio only had generally small, nonsignificant increases in the odds of adverse outcomes. Patients having airflow limitation based on both fixed ratio and lower limit of normal had larger, significant increases in odds. But strongest associations were seen for patients who had airflow limitation by both fixed ratio and lower limit of normal and also had a low FEV1, defined as one less than 80% of the predicted value. Our results suggest that use of the fixed ratio alone may lead to misdiagnosis of COPD. A diagnosis established by both a low FEV1/FVC (according to fixed ratio and/or lower limit of normal) and a low FEV1 is strongly associated with clinical outcomes. Guidelines should be reconsidered to require both spirometry abnormalities so as to reduce overdiagnosis of COPD. © 2015 Annals of Family Medicine, Inc.
Burning Plastics Investigated in Space for Unique US/Russian Cooperative Project
NASA Technical Reports Server (NTRS)
Friedman, Robert
2000-01-01
It is well known that fires in the low-gravity environment of Earth-orbiting spacecraft are different from fires on Earth. The flames lack the familiar upward plume, which is the result of gravitational buoyancy. These flames, however, are strongly influenced by minor airflow currents. A recent study conducted in low gravity (microgravity) on the Russian orbital station Mir used burning plastic rods mounted in a small chamber with a controllable fan to expose the flame to airflows of different velocities. In this unique project, a Russian scientific agency, the Keldysh Research Center, furnished the apparatus and directed the Mir tests, while the NASA Glenn Research Center at Lewis Field provided the test materials and the project management. Reference testing and calibrations in ground laboratories were conducted jointly by researchers at Keldysh and at the NASA Johnson Space Center's White Sands Test Facility. Multiple samples of three different plastics were burned in the tests: Delrin, a common material for valve bodies; PMMA, a plastic "glass"; and polyethylene, a familiar material for containers and films. Each burned with a unique spherical or egg-shaped flame that spread over the rod. The effect of varying the airflow was dramatic. At the highest airflow attainable in the combustion chamber, nearly 10 cm/sec (a typical ventilation breeze), the flames were bright and strong. As airflow velocity decreased, the flames became shorter but wider. In addition, the flames became less bright, and for PMMA and polyethylene, they showed two colors, a bright part decreasing in volume and a nearly invisible remainder (see the photographs). Finally, at a very low velocity, the flames extinguished. For the plastics tested, this minimum velocity was very low, around 0.3 to 0.5 cm/sec. This finding confirms that at least a slight airflow is required to maintain a flame in microgravity for these types of materials.
ADVANTG Shielding Analysis for Closure Operations in an Open-Mode Repository
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevill, Aaron M; Radulescu, Georgeta; Scaglione, John M
2013-01-01
en-mode repository concepts could require worker entry into access drifts after placement of fuel casks in order to perform activities related to backfill, plug emplacement, routine maintenance, or performance confirmation. An ideal emplacement-drift shielding configuration would minimize dose to workers while maximizing airflow through the emplacement drifts. This paper presents a preliminary investigation of the feasibility and effectiveness of radiation shielding concepts that could be employed to facilitate worker operations in an open-mode repository. The repository model for this study includes pressurized-water reactor fuel assemblies (60 GWd/MTU burnup, 40 year post-irradiation cooldown) in packages of 32 assemblies. The closest fuelmore » packages are 5 meters from dosimetry voxels in the access drift. The unshielded dose to workers in the access drift is 73.7 rem/hour. Prior work suggests that open-mode repository concepts similar to this one would require 15 m3/s of ventilation airflow. Shielding concepts considered here include partial concrete plugs, labyrinthine shields, and stainless steel photon attenuator grids. Maximum dose to workers in the access drift was estimated for each shielding concept using MCNP5 with variance reduction parameters generated by ADVANTG. Because airflow through the shielding is important for open-mode repositories, a semi-empirical estimate of the head loss due to each shielding configuration was also calculated. Airflow and shielding performance vary widely among the proposed shielding configurations. Although the partial plug configuration had the best airflow performance, it allowed dose rates 1500 greater than the specified target. Labyrinthine shielding concepts yield doses on the order of 1 mrem/hour with configurations that impose 3 to 11 J/kg head loss. Adding 1 cm lead lining to the airflow channels of labyrinthine designs further reduces the worker dose by 65% to 95%. Photon-attenuator concepts may reduce worker dose to as low as 29 mrem/hour with head loss on the order of 1.9 J/kg.« less
CPAP Devices for Emergency Prehospital Use: A Bench Study.
Brusasco, Claudia; Corradi, Francesco; De Ferrari, Alessandra; Ball, Lorenzo; Kacmarek, Robert M; Pelosi, Paolo
2015-12-01
CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model the performance of 3 orofacial mask devices (Ventumask, EasyVent, and Boussignac CPAP system) and 2 helmets (Ventukit and EVE Coulisse) used to apply CPAP in the prehospital setting. A static test evaluated air-flow output, positive pressure applied, and FIO2 delivered by each device. A dynamic test assessed airway pressure stability during simulated ventilation. Efficiency of devices was compared based on oxygen flow needed to generate a minimum air flow of 60 L/min at each CPAP setting. The EasyVent and EVE Coulisse devices delivered significantly higher mean air-flow outputs compared with the Ventumask and Ventukit under all CPAP conditions tested. The Boussignac CPAP system never reached an air-flow output of 60 L/min. The EasyVent had significantly lower pressure excursion than the Ventumask at all CPAP levels, and the EVE Coulisse had lower pressure excursion than the Ventukit at 5, 15, and 20 cm H2O, whereas at 10 cm H2O, no significant difference was observed between the 2 devices. Estimated oxygen consumption was lower for the EasyVent and EVE Coulisse compared with the Ventumask and Ventukit. Air-flow output, pressure applied, FIO2 delivered, device oxygen consumption, and ability to maintain air flow at 60 L/min differed significantly among the CPAP devices tested. Only the EasyVent and EVE Coulisse achieved the required minimum level of air-flow output needed to ensure an effective therapy under all CPAP conditions. Copyright © 2015 by Daedalus Enterprises.
DiMarco, Anthony F.; Kowalski, Krzysztof E.; Geertman, Robert T.; Hromyak, Dana R.
2009-01-01
Objective Evaluation of the capacity of lower thoracic spinal cord stimulation (SCS) to activate the expiratory muscles and generate large airway pressures and high peak airflows characteristic of cough, in subjects with tetraplegia. Design Clinical trial. Setting In-patient hospital setting for electrode insertion; out-patient setting for measurement of respiratory pressures; home setting for application of SCS. Participants Subjects (N = 9; 8 men, 1 woman) with cervical spinal cord injury and weak cough. Intervention(s) A fully implantable electrical stimulation system was surgically placed in each subject. Partial hemilaminectomies were made to place single-disc electrodes in the epidural space at the T9, T11 and L1 spinal levels. A radiofrequency receiver was placed in the subcutaneous pocket over the anterior portion of the chest wall. Electrode wires were tunneled subcutaneously and connected to the receiver. Stimulation was applied by activating a small portable external stimulus controller box powered by a rechargeable battery to each electrode lead alone and in combination. Main Outcome Measure(s) Airway pressure and peak airflow generation achieved with SCS. Results Supramaximal SCS resulted in large airway pressures and high peak airflow rates during stimulation at each electrode lead. Maximum airway pressures and peak airflow rates were achieved with combined stimulation of any 2 leads. At total lung capacity, mean maximum airway pressure generation and peak airflow rates were 137 ± 30 cmH2O (mean ± SE) and 8.6 ± 1.8 (mean ± SE) L/s, respectively. Conclusions Lower thoracic SCS results in near maximum activation of the expiratory muscles and the generation of high positive airway pressures and peak airflow rates in the range of those observed with maximum cough efforts in normal individuals. PMID:19406289
NASA Astrophysics Data System (ADS)
Thompson, M. A.; Lindsay, J. M.; Gaillard, J.
2015-12-01
Globally, geological hazards are communicated using maps. In traditional hazard mapping practice, scientists analyse data about a hazard, and then display the results on a map for stakeholder and public use. However, this one-way, top-down approach to hazard communication is not necessarily effective or reliable. The messages which people take away will be dependent on the way in which they read, interpret, and understand the map, a facet of hazard communication which has been relatively unexplored. Decades of cartographic studies suggest that variables in the visual representation of data on maps, such as colour and symbology, can have a powerful effect on how people understand map content. In practice, however, there is little guidance or consistency in how hazard information is expressed and represented on maps. Accordingly, decisions are often made based on subjective preference, rather than research-backed principles. Here we present the results of a study in which we explore how hazard map design features can influence hazard map interpretation, and we propose a number of considerations for hazard map design. A series of hazard maps were generated, with each one showing the same probabilistic volcanic ashfall dataset, but using different verbal and visual variables (e.g., different colour schemes, data classifications, probabilistic formats). Following a short pilot study, these maps were used in an online survey of 110 stakeholders and scientists in New Zealand. Participants answered 30 open-ended and multiple choice questions about ashfall hazard based on the different maps. Results suggest that hazard map design can have a significant influence on the messages readers take away. For example, diverging colour schemes were associated with concepts of "risk" and decision-making more than sequential schemes, and participants made more precise estimates of hazard with isarithmic data classifications compared to binned or gradational shading. Based on such findings, we make a number of suggestions for communicating hazard using maps. Most importantly, we emphasise that multiple meanings may be taken away from a map, and this may have important implications in a crisis. We propose that engaging with map audiences in a two-way dialogue in times of peace may help prevent miscommunications in the event of a crisis.
Dion, Gregory R; Achlatis, Efstratios; Teng, Stephanie; Fang, Yixin; Persky, Michael; Branski, Ryan C; Amin, Milan R
2017-11-01
Compromised cough effectiveness is correlated with dysphagia and aspiration. Glottic insufficiency likely yields decreased cough strength and effectiveness. Although vocal fold augmentation favorably affects voice and likely improves cough strength, few data exist to support this hypothesis. To assess whether vocal fold augmentation improves peak airflow measurements during maximal-effort cough following augmentation. This case series study was conducted in a tertiary, academic laryngology clinic. Participants included 14 consecutive individuals with glottic insufficiency due to vocal fold paralysis, which was diagnosed via videostrobolaryngoscopy as a component of routine clinical examination. All participants who chose to proceed with augmentation were considered for the study whether office-based or operative augmentation was planned. Postaugmentation data were collected only at the first follow-up visit, which was targeted for 14 days after augmentation but varied on the basis of participant availability. Data were collected from June 5, 2014, to October 1, 2015. Data analysis took place between October 2, 2015, and March 3, 2017. Peak airflow during maximal volitional cough was quantified before and after vocal fold augmentation. Participants performed maximal coughs, and peak expiratory flow during the maximal cough was captured according to American Thoracic Society guidelines. Among the 14 participants (7 men and 7 women), the mean (SD) age was 62 (18) years. Three types of injectable material were used for vocal fold augmentation: carboxymethylcellulose in 5 patients, hyaluronic acid in 5, and calcium hydroxylapatite in 4. Following augmentation, cough strength increased in 11 participants and decreased cough strength was observed in 3. Peak airflow measurements during maximal cough varied from a decrease of 40 L/min to an increase of 150 L/min following augmentation. When preaugmentation and postaugmentation peak airflow measurements were compared, the median improvement was 50 L/min (95% CI, 10-75 L/min; P = .01). Immediate peak airflow measurements during cough collected within 30 minutes of augmentation varied when compared with measurements collected at follow-up (103-380 vs 160-390 L/min). Peak airflow during maximal cough may improve with vocal fold augmentation. Additional assessment and measurements are needed to further delineate which patients will benefit most regarding their cough from vocal fold augmentation.
Laparoscopic access with a visualizing trocar.
Wolf, J S
1997-01-01
Although useful in most situations, there are several inherent disadvantages of the standard laparoscopic access techniques of Veress needle insertion and Hasson-type cannula placement. Veress needle placement may be hazardous in patients at high risk for intraabdominal adhesions and difficult in patients who are obese. The usual alternative, the Hasson-type cannula, often does not provide a good gas seal. As another option, the use of a visualizing trocar (OPTIVIEW) has proven to be effective in the initial experience at the University of Michigan. The inner trocar of the visualizing trocar is hollow except for a clear plastic conical tip with two external ridges. The trocar-cannula assembly is passed through tissue layers to enter the operative space under direct vision from a 10-mm zero-degree laparoscope placed into the trocar. Results suggest that this technique is an excellent alternative to Veress needle placement when laparoscopic access is likely to be hazardous or difficult.
NASA Astrophysics Data System (ADS)
Tonini, Roberto; Selva, Jacopo; Costa, Antonio; Sandri, Laura
2014-05-01
Probabilistic Hazard Assessment (PHA) is becoming an essential tool for risk mitigation policies, since it allows to quantify the hazard due to hazardous phenomena and, differently from the deterministic approach, it accounts for both aleatory and epistemic uncertainties. On the other hand, one of the main disadvantages of PHA methods is that their results are not easy to understand and interpret by people who are not specialist in probabilistic tools. For scientists, this leads to the issue of providing tools that can be easily used and understood by decision makers (i.e., risk managers or local authorities). The work here presented fits into the problem of simplifying the transfer between scientific knowledge and land protection policies, by providing an interface between scientists, who produce PHA's results, and decision makers, who use PHA's results for risk analyses. In this framework we present pyPHaz, an open tool developed and designed to visualize and analyze PHA results due to one or more phenomena affecting a specific area of interest. The software implementation has been fully developed with the free and open-source Python programming language and some featured Python-based libraries and modules. The pyPHaz tool allows to visualize the Hazard Curves (HC) calculated in a selected target area together with different levels of uncertainty (mean and percentiles) on maps that can be interactively created and modified by the user, thanks to a dedicated Graphical User Interface (GUI). Moreover, the tool can be used to compare the results of different PHA models and to merge them, by creating ensemble models. The pyPHaz software has been designed with the features of storing and accessing all the data through a MySQL database and of being able to read as input the XML-based standard file formats defined in the frame of GEM (Global Earthquake Model). This format model is easy to extend also to any other kind of hazard, as it will be shown in the applications here used as examples of the pyPHaz potentialities, that are focused on a Probabilistic Volcanic Hazard Assessment (PVHA) for tephra dispersal and fallout applied to the municipality of Naples.
A Resonant Pulse Detonation Actuator for High-Speed Boundary Layer Separation Control
NASA Technical Reports Server (NTRS)
Beck, B. T.; Cutler, A. D.; Drummond, J. P.; Jones, S. B.
2004-01-01
A variety of different types of actuators have been previously investigated as flow control devices. Potential applications include the control of boundary layer separation in external flows, as well as jet engine inlet and diffuser flow control. The operating principles for such devices are typically based on either mechanical deflection of control surfaces (which include MEMS flap devices), mass injection (which includes combustion driven jet actuators), or through the use of synthetic jets (diaphragm devices which produce a pulsating jet with no net mass flow). This paper introduces some of the initial flow visualization work related to the development of a relatively new type of combustion-driven jet actuator that has been proposed based on a pulse detonation principle. The device is designed to utilize localized detonation of a premixed fuel (Hydrogen)-air mixture to periodically inject a jet of gas transversely into the primary flow. Initial testing with airflow successfully demonstrated resonant conditions within the range of acoustic frequencies expected for the design. Schlieren visualization of the pulsating air jet structure revealed axially symmetric vortex flow, along with the formation of shocks. Flow visualization of the first successful sustained oscillation condition is also demonstrated for one configuration of the current test section. Future testing will explore in more detail the onset of resonant combustion and the approach to conditions of sustained resonant detonation.
Using Integrated Earth and Social Science Data for Disaster Risk Assessment
NASA Astrophysics Data System (ADS)
Downs, R. R.; Chen, R. S.; Yetman, G.
2016-12-01
Society faces many different risks from both natural and technological hazards. In some cases, disaster risk managers focus on only a few risks, e.g., in regions where a single hazard such as earthquakes dominate. More often, however, disaster risk managers deal with multiple hazards that pose diverse threats to life, infrastructure, and livelihoods. From the viewpoint of scientists, hazards are often studied based on traditional disciplines such as seismology, hydrology, climatology, and epidemiology. But from the viewpoint of disaster risk managers, data are needed on all hazards in a specific region and on the exposure and vulnerability of population, infrastructure, and economic resources and activity. Such managers also need to understand how hazards, exposures, and vulnerabilities may interact, and human and environmental systems respond, to hazard events, as in the case of the Fukushima nuclear disaster that followed from the Sendai earthquake and tsunami. In this regard, geospatial tools that enable visualization and analysis of both Earth and social science data can support the use case of disaster risk managers who need to quickly assess where specific hazard events occur relative to population and critical infrastructure. Such information can help them assess the potential severity of actual or predicted hazard events, identify population centers or key infrastructure at risk, and visualize hazard dynamics, e.g., earthquakes and their aftershocks or the paths of severe storms. This can then inform efforts to mitigate risks across multiple hazards, including reducing exposure and vulnerability, strengthening system resiliency, improving disaster response mechanisms, and targeting mitigation resources to the highest or most critical risks. We report here on initial efforts to develop hazard mapping tools that draw on open web services and support simple spatial queries about population exposure. The NASA Socioeconomic Data and Applications Center (SEDAC) Hazards Mapper, a web-based mapping tool, enables users to estimate population living in areas subject to flood or tornado warnings, near recent earthquakes, or around critical infrastructure. The HazPop mobile app, implemented for iOS devices, utilizes location services to support disaster risk managers working in field conditions.
NASA Astrophysics Data System (ADS)
Ding, R.; He, T.
2017-12-01
With the increased popularity in mobile applications and services, there has been a growing demand for more advanced mobile technologies that utilize real-time Location Based Services (LBS) data to support natural hazard response efforts. Compared to traditional sources like the census bureau that often can only provide historical and static data, an LBS service can provide more current data to drive a real-time natural hazard response system to more accurately process and assess issues such as population density in areas impacted by a hazard. However, manually preparing or preprocessing the data to suit the needs of the particular application would be time-consuming. This research aims to implement a population heatmap visual analytics system based on real-time data for natural disaster emergency management. System comprised of a three-layered architecture, including data collection, data processing, and visual analysis layers. Real-time, location-based data meeting certain polymerization conditions are collected from multiple sources across the Internet, then processed and stored in a cloud-based data store. Parallel computing is utilized to provide fast and accurate access to the pre-processed population data based on criteria such as the disaster event and to generate a location-based population heatmap as well as other types of visual digital outputs using auxiliary analysis tools. At present, a prototype system, which geographically covers the entire region of China and combines population heat map based on data from the Earthquake Catalogs database has been developed. It Preliminary results indicate that the generation of dynamic population density heatmaps based on the prototype system has effectively supported rapid earthquake emergency rescue and evacuation efforts as well as helping responders and decision makers to evaluate and assess earthquake damage. Correlation analyses that were conducted revealed that the aggregation and movement of people depended on various factors, including earthquake occurrence time and location of epicenter. This research hopes to continue to build upon the success of the prototype system in order to improve and extend the system to support the analysis of earthquakes and other types of natural hazard events.
Study of Airflow Out of the Mouth During Speech.
ERIC Educational Resources Information Center
Catford, J.C.; And Others
Airflow outside the mouth is diagnostic of articulatory activities in the vocal tract, both total volume-velocity and the distribution of particle velocities over the flow-front being useful for this purpose. A system for recording and displaying both these types of information is described. This consists of a matrix of l6 hot-wire anemometer flow…
Biomechanics of conidial dispersal in the toxic mold Stachybotrys chartarum
Tucker, Kathryn; Stolze, Jessica L.; Kennedy, Aaron H.; Money, Nicholas P.
2007-01-01
Conidial dispersal in Stachybotrys chartarum in response to low-velocity airflow was studied using a microflow apparatus. The maximum rate of spore release occurred during the first 5 min of airflow, followed by a dramatic reduction in dispersal that left more than 99% of the conidia attached to their conidiophores. Micromanipulation of undisturbed colonies showed that micronewton (μN) forces were needed to dislodge spore clusters from their supporting conidiophores. Calculations show that airspeeds that normally prevail in the indoor environment disturb colonies with forces that are 1,000-fold lower, in the nanonewton (nN) range. Low-velocity airflow does not, therefore, cause sufficient disturbance to disperse a large proportion of the conidia of S. chartarum. PMID:17267247
Cartograms Facilitate Communication of Climate Change Risks and Responsibilities
NASA Astrophysics Data System (ADS)
Döll, Petra
2017-12-01
Communication of climate change (CC) risks is challenging, in particular if global-scale spatially resolved quantitative information is to be conveyed. Typically, visualization of CC risks, which arise from the combination of hazard, exposure and vulnerability, is confined to showing only the hazards in the form of global thematic maps. This paper explores the potential of contiguous value-by-area cartograms, that is, distorted density-equalizing maps, for improving communication of CC risks and the countries' differentiated responsibilities for CC. Two global-scale cartogram sets visualize, as an example, groundwater-related CC risks in 0.5° grid cells, another one the correlation of (cumulative) fossil-fuel carbon dioxide emissions with the countries' population and gross domestic product. Viewers of the latter set visually recognize the lack of global equity and that the countries' wealth has been built on harmful emissions. I recommend that CC risks are communicated by bivariate gridded cartograms showing the hazard in color and population, or a combination of population and a vulnerability indicator, by distortion of grid cells. Gridded cartograms are also appropriate for visualizing the availability of natural resources to humans. For communicating complex information, sets of cartograms should be carefully designed instead of presenting single cartograms. Inclusion of a conventionally distorted map enhances the viewers' capability to take up the information represented by distortion. Empirical studies about the capability of global cartograms to convey complex information and to trigger moral emotions should be conducted, with a special focus on risk communication.
Structural dynamics and aerodynamics measurements of biologically inspired flexible flapping wings.
Wu, P; Stanford, B K; Sällström, E; Ukeiley, L; Ifju, P G
2011-03-01
Flapping wing flight as seen in hummingbirds and insects poses an interesting unsteady aerodynamic problem: coupling of wing kinematics, structural dynamics and aerodynamics. There have been numerous studies on the kinematics and aerodynamics in both experimental and computational cases with both natural and artificial wings. These studies tend to ignore wing flexibility; however, observation in nature affirms that passive wing deformation is predominant and may be crucial to the aerodynamic performance. This paper presents a multidisciplinary experimental endeavor in correlating a flapping micro air vehicle wing's aeroelasticity and thrust production, by quantifying and comparing overall thrust, structural deformation and airflow of six pairs of hummingbird-shaped membrane wings of different properties. The results show that for a specific spatial distribution of flexibility, there is an effective frequency range in thrust production. The wing deformation at the thrust-productive frequencies indicates the importance of flexibility: both bending and twisting motion can interact with aerodynamic loads to enhance wing performance under certain conditions, such as the deformation phase and amplitude. By measuring structural deformations under the same aerodynamic conditions, beneficial effects of passive wing deformation can be observed from the visualized airflow and averaged thrust. The measurements and their presentation enable observation and understanding of the required structural properties for a thrust effective flapping wing. The intended passive responses of the different wings follow a particular pattern in correlation to their aerodynamic performance. Consequently, both the experimental technique and data analysis method can lead to further studies to determine the design principles for micro air vehicle flapping wings.
Manjunatha, Roopa G; Rajanna, K; Mahapatra, D Roy; Prakash, Surya
2014-01-01
Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction. Because of piezoelectric property, two PVDF nasal sensors provide output voltage signals corresponding to the right and left nostril when they are subjected to nasal airflow. The peak-to-peak amplitude of the voltage signal corresponding to nasal airflow was analyzed to assess the nasal obstruction. PVDF nasal sensor and PNIF were performed on 30 healthy subjects and 30 DNS patients. Receiver operating characteristic was used to analyze the DNS of these two methods. Measurements of PVDF nasal sensor strongly correlated with findings of PNIF (r = 0.67; p < 0.01) in DNS patients. A significant difference (p < 0.001) was observed between PVDF nasal sensor measurements and PNIF measurements of the DNS and the control group. A cutoff between normal and pathological of 0.51 Vp-p for PVDF nasal sensor and 120 L/min for PNIF was calculated. No significant difference in terms of sensitivity of PVDF nasal sensor and PNIF (89.7% versus 82.6%) and specificity (80.5% versus 78.8%) was calculated. The result shows that PVDF measurements closely agree with PNIF findings. Developed PVDF nasal sensor is an objective method that is simple, inexpensive, fast, and portable for determining DNS in clinical practice.
Local Heat Transfer for Finned-Tube Heat Exchangers using Oval Tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Brien, James Edward; Sohal, Manohar Singh
2000-08-01
This paper presents the results of an experimental study of forced convection heat transfer in a narrow rectangular duct fitted with either a circular tube or an elliptical tube in crossflow. The duct was designed to simulate a single passage in a fin-tube heat exchanger. Heat transfer measurements were obtained using a transient technique in which a heated airflow is suddenly introduced to the test section. High-resolution local fin-surface temperature distributions were obtained at several times after initiation of the transient using an imaging infrared camera. Corresponding local fin-surface heat transfer coefficient distributions were then calculated from a locally appliedmore » one-dimensional semi-infinite inverse heat conduction model. Heat transfer results were obtained over an airflow rate ranging from 1.56 x 10-3 to 15.6 x 10-3 kg/s. These flow rates correspond to a duct-height Reynolds number range of 630 – 6300 with a duct height of 1.106 cm and a duct width-toheight ratio, W/H, of 11.25. The test cylinder was sized such that the diameter-to-duct height ratio, D/H is 5. The elliptical tube had an aspect ratio of 3:1 and a/H equal to 4.33. Results presented in this paper reveal visual and quantitative details of local fin-surface heat transfer distributions in the vicinity of circular and oval tubes and their relationship to the complex horseshoe vortex system that forms in the flow stagnation region. Fin surface stagnation-region Nusselt numbers are shown to be proportional to the square-root of Reynolds number.« less
NASA Astrophysics Data System (ADS)
Sittenfeld, D.; Choi, F.; Farooque, M.; Helmuth, B.
2017-12-01
Because climate hazards present a range of potential impacts and considerations for different kinds of stakeholders, community responses to increase resilience are best considered through the inclusion of diverse, informed perspectives. The Science Center Public Forums project has created multifaceted modules to engage diverse publics in substantive deliberations around four hazards: heat waves, drought, extreme precipitation, and sea level rise. Using a suite of background materials including visualization and narrative components, each of these daylong dialogues engage varied groups of lay-participants at eight US science centers in learning about hazard vulnerabilities and tradeoffs of proposed strategies for building resilience. Participants listen to and consider the priorities and perspectives of fellow residents and stakeholders, and work together to formulate detailed resilience plans reflecting both current science and informed public values. Deliverables for the project include visualizations of hazard vulnerabilities and strategies through immersive planetarium graphics and Google Earth, stakeholder perspective narratives, and detailed background materials for each project hazard. This session will: communicate the process for developing the hazard modules with input from subject matter experts, outline the process for iterative revisions based upon findings from formative focus groups, share results generated by participants of the project's first two pilot forums, and describe plans for broader implementation. These activities and outcomes could help to increase the capacity of informal science education institutions as trusted conveners for informed community dialogue by educating residents about vulnerabilities and engaging them in critical thinking about potential policy responses to critical climate hazards while sharing usable public values and priorities with civic planners.
Vatovec, Christine
2013-01-01
Theory-based research is needed to understand how maps of environmental health risk information influence risk beliefs and protective behavior. Using theoretical concepts from multiple fields of study including visual cognition, semiotics, health behavior, and learning and memory supports a comprehensive assessment of this influence. We report results from thirteen cognitive interviews that provide theory-based insights into how visual features influenced what participants saw and the meaning of what they saw as they viewed three formats of water test results for private wells (choropleth map, dot map, and a table). The unit of perception, color, proximity to hazards, geographic distribution, and visual salience had substantial influences on what participants saw and their resulting risk beliefs. These influences are explained by theoretical factors that shape what is seen, properties of features that shape cognition (pre-attentive, symbolic, visual salience), information processing (top-down and bottom-up), and the strength of concrete compared to abstract information. Personal relevance guided top-down attention to proximal and larger hazards that shaped stronger risk beliefs. Meaning was more local for small perceptual units and global for large units. Three aspects of color were important: pre-attentive “incremental risk” meaning of sequential shading, symbolic safety meaning of stoplight colors, and visual salience that drew attention. The lack of imagery, geographic information, and color diminished interest in table information. Numeracy and prior beliefs influenced comprehension for some participants. Results guided the creation of an integrated conceptual framework for application to future studies. Ethics should guide the selection of map features that support appropriate communication goals. PMID:22715919
Severtson, Dolores J; Vatovec, Christine
2012-08-01
Theory-based research is needed to understand how maps of environmental health risk information influence risk beliefs and protective behavior. Using theoretical concepts from multiple fields of study including visual cognition, semiotics, health behavior, and learning and memory supports a comprehensive assessment of this influence. The authors report results from 13 cognitive interviews that provide theory-based insights into how visual features influenced what participants saw and the meaning of what they saw as they viewed 3 formats of water test results for private wells (choropleth map, dot map, and a table). The unit of perception, color, proximity to hazards, geographic distribution, and visual salience had substantial influences on what participants saw and their resulting risk beliefs. These influences are explained by theoretical factors that shape what is seen, properties of features that shape cognition (preattentive, symbolic, visual salience), information processing (top-down and bottom-up), and the strength of concrete compared with abstract information. Personal relevance guided top-down attention to proximal and larger hazards that shaped stronger risk beliefs. Meaning was more local for small perceptual units and global for large units. Three aspects of color were important: preattentive "incremental risk" meaning of sequential shading, symbolic safety meaning of stoplight colors, and visual salience that drew attention. The lack of imagery, geographic information, and color diminished interest in table information. Numeracy and prior beliefs influenced comprehension for some participants. Results guided the creation of an integrated conceptual framework for application to future studies. Ethics should guide the selection of map features that support appropriate communication goals.
Bronchial obstruction secondary to idiopathic scoliosis in a child: a case report
Alotaibi, Saad; Harder, James; Spier, Sheldon
2008-01-01
Introduction Patients with severe idiopathic scoliosis are reported to have significant pulmonary complications, including recurrent chest infections, alveolar hypoventilation and respiratory failure. Case presentation We report a case of a 13-year-old boy with moderate-to-severe scoliosis resulting in torsion or twisting of the bronchus intermedius, which contributed to airflow obstruction defects, as revealed by both spirometry and bronchoscopy. Conclusion We recommend that inspection of the shape of the maximal expiratory flow-volume loop obtained from spirometry, as well as other parameters suggestive of obstructive lung disease, may be important in children with scoliosis. To the best of the authors' knowledge, this is the first report of a child in which pulmonary function testing and direct visualization via a flexible bronchoscope have been used to characterize intrathoracic large airway obstruction. PMID:18498624
Natural ventilation without air breathing in the top openings of highway tunnels
NASA Astrophysics Data System (ADS)
Jin, Sike; Jin, Jiali; Gong, Yanfeng
2017-05-01
A number of urban shallow-buried highway tunnels have been built in China. Despite much better internal air quality compared to the traditional tunnels, there is no sufficient theoretical ground or experimental support for the construction of such tunnels. Most researchers hold that natural ventilation in such tunnels depends on air breathing in the top openings, but some others are skeptical about this conclusion. By flow visualization technology on a tunnel experiment platform, we tested the characteristics of airflow in the top openings of highway tunnels. The results showed that air always flowed from outside to inside in all top openings above a continuous traffic stream, and the openings did not breathe at all. In addition, intake air in the top openings reached its maximum velocity at the tunnel entrance, and then gradually slowed down with tunnel depth increasing.
Influence of the Pressure Difference and Door Swing on Heavy Contaminants Migration between Rooms
Hendiger, Jacek; Chludzińska, Marta; Ziętek, Piotr
2016-01-01
This paper presents the results of investigations whose aim was to describe the influence of the pressure difference level on the ability of contaminants migration between neighbouring rooms in dynamic conditions associated with door swing. The analysis was based on airflow visualization made with cold smoke, which simulated the heavy contaminants. The test room was pressurized to a specific level and then the door was opened to observe the trail of the smoke plume in the plane of the door. The door was opened in both directions: to the positively and negatively pressurized room. This study focuses on the visualization of smoke plume discharge and an uncertainty analysis is not applicable. Unlike other studies which focus on the analysis of pressure difference, the present study looks at the contaminants which are heavier than air and on “pumping out” the contaminants by means of door swing. Setting the proper level of pressure difference between the contaminated room and the neighbouring rooms can prove instrumental in ensuring protection against toxic contaminants migration. This study helped to establish the threshold of pressure difference necessary to reduce migration of heavy contaminants to neighbouring rooms. PMID:27171260
Influence of the Pressure Difference and Door Swing on Heavy Contaminants Migration between Rooms.
Hendiger, Jacek; Chludzińska, Marta; Ziętek, Piotr
2016-01-01
This paper presents the results of investigations whose aim was to describe the influence of the pressure difference level on the ability of contaminants migration between neighbouring rooms in dynamic conditions associated with door swing. The analysis was based on airflow visualization made with cold smoke, which simulated the heavy contaminants. The test room was pressurized to a specific level and then the door was opened to observe the trail of the smoke plume in the plane of the door. The door was opened in both directions: to the positively and negatively pressurized room. This study focuses on the visualization of smoke plume discharge and an uncertainty analysis is not applicable. Unlike other studies which focus on the analysis of pressure difference, the present study looks at the contaminants which are heavier than air and on "pumping out" the contaminants by means of door swing. Setting the proper level of pressure difference between the contaminated room and the neighbouring rooms can prove instrumental in ensuring protection against toxic contaminants migration. This study helped to establish the threshold of pressure difference necessary to reduce migration of heavy contaminants to neighbouring rooms.
Salisbury, Margaret L; Lynch, David A; van Beek, Edwin J R; Kazerooni, Ella A; Guo, Junfeng; Xia, Meng; Murray, Susan; Anstrom, Kevin J; Yow, Eric; Martinez, Fernando J; Hoffman, Eric A; Flaherty, Kevin R
2017-04-01
Adaptive multiple features method (AMFM) lung texture analysis software recognizes high-resolution computed tomography (HRCT) patterns. To evaluate AMFM and visual quantification of HRCT patterns and their relationship with disease progression in idiopathic pulmonary fibrosis. Patients with idiopathic pulmonary fibrosis in a clinical trial of prednisone, azathioprine, and N-acetylcysteine underwent HRCT at study start and finish. Proportion of lung occupied by ground glass, ground glass-reticular (GGR), honeycombing, emphysema, and normal lung densities were measured by AMFM and three radiologists, documenting baseline disease extent and postbaseline change. Disease progression includes composite mortality, hospitalization, and 10% FVC decline. Agreement between visual and AMFM measurements was moderate for GGR (Pearson's correlation r = 0.60, P < 0.0001; mean difference = -0.03 with 95% limits of agreement of -0.19 to 0.14). Baseline extent of GGR was independently associated with disease progression when adjusting for baseline Gender-Age-Physiology stage and smoking status (hazard ratio per 10% visual GGR increase = 1.98, 95% confidence interval [CI] = 1.20-3.28, P = 0.008; and hazard ratio per 10% AMFM GGR increase = 1.36, 95% CI = 1.01-1.84, P = 0.04). Postbaseline visual and AMFM GGR trajectories were correlated with postbaseline FVC trajectory (r = -0.30, 95% CI = -0.46 to -0.11, P = 0.002; and r = -0.25, 95% CI = -0.42 to -0.06, P = 0.01, respectively). More extensive baseline visual and AMFM fibrosis (as measured by GGR densities) is independently associated with elevated hazard for disease progression. Postbaseline change in AMFM-measured and visually measured GGR densities are modestly correlated with change in FVC. AMFM-measured fibrosis is an automated adjunct to existing prognostic markers and may allow for study enrichment with subjects at increased disease progression risk.
Determinants of spirometric abnormalities among silicotic patients in Hong Kong.
Leung, Chi C; Chang, Kwok C; Law, Wing S; Yew, Wing W; Tam, Cheuk M; Chan, Chi K; Wong, Man Y
2005-09-01
Silicosis is the second commonest notified occupational disease in Hong Kong. To characterize the determinants of spirometric abnormalities in silicosis. The spirometric patterns of consecutive silicotic patients on confirmation by the Pneumoconiosis Medical Board from 1991 to 2002 were correlated with demographic characteristics, occupational history, smoking history, tuberculosis (TB) history and radiographic features by univariate and multiple regression analyses. Of 1576 silicotic patients included, 55.6% showed normal spirometry, 28.5% normal forced vital capacity (FVC>or=80% predicted) but reduced forced expiratory ratio (FER<70%), 7.6% reduced FVC but normal FER, and 8.4% reduced both FVC and FER. Age, ever-smoking, cigarette pack-years, industry, job type, history of TB, size of lung nodules and progressive massive fibrosis (PMF) were all significantly associated with airflow limitation on univariate analysis (all P<0.05), while sex and profusion of nodules were not. Only age, cigarette pack-years, history of TB, size of lung nodules and PMF remained as significant independent predictors of airflow obstruction in multiple logistic regression analysis. After controlling for airflow obstruction, only shorter exposure duration, history of TB and profusion of nodules were significant independent predictors of reduced FVC. As well as age, history of TB, cigarette pack-years, PMF and nodule size contributed comparable effects to airflow obstruction in multiple linear regression analyses, while profusion of nodules was the strongest factor for reduced vital capacity. In an occupational compensation setting, disease indices and history of tuberculosis are independent predictors of both airflow obstruction and reduced vital capacity for silicotic patients.
Kimbell, Julia S; Segal, Rebecca A; Asgharian, Bahman; Wong, Brian A; Schroeter, Jeffry D; Southall, Jeremy P; Dickens, Colin J; Brace, Geoff; Miller, Frederick J
2007-01-01
Many studies suggest limited effectiveness of spray devices for nasal drug delivery due primarily to high deposition and clearance at the front of the nose. Here, nasal spray behavior was studied using experimental measurements and a computational fluid dynamics model of the human nasal passages constructed from magnetic resonance imaging scans of a healthy adult male. Eighteen commercially available nasal sprays were analyzed for spray characteristics using laser diffraction, high-speed video, and high-speed spark photography. Steadystate, inspiratory airflow (15 L/min) and particle transport were simulated under measured spray conditions. Simulated deposition efficiency and spray behavior were consistent with previous experimental studies, two of which used nasal replica molds based on this nasal geometry. Deposition fractions (numbers of deposited particles divided by the number released) of 20- and 50-microm particles exceeded 90% in the anterior part of the nose for most simulated conditions. Predicted particle penetration past the nasal valve improved when (1) the smaller of two particle sizes or the lower of two spray velocities was used, (2) the simulated nozzle was positioned 1.0 rather than 0.5 or 1.5 cm into the nostril, and (3) inspiratory airflow was present rather than absent. Simulations also predicted that delaying the appearance of normal inspiratory airflow more than 1 sec after the release of particles produced results equivalent to cases in which no inspiratory airflow was present. These predictions contribute to more effective design of drug delivery devices through a better understanding of the effects of nasal airflow and spray characteristics on particle transport in the nose.
Ethmoidectomy combined with superior meatus enlargement increases olfactory airflow
Kondo, Kenji; Nomura, Tsutomu; Yamasoba, Tatsuya
2017-01-01
Objectives The relationship between a particular surgical technique in endoscopic sinus surgery (ESS) and airflow changes in the post‐operative olfactory region has not been assessed. The present study aimed to compare olfactory airflow after ESS between conventional ethmoidectomy and ethmoidectomy with superior meatus enlargement, using virtual ESS and computational fluid dynamics (CFD) analysis. Study Design Prospective computational study. Materials and Methods Nasal computed tomography images of four adult subjects were used to generate models of the nasal airway. The original preoperative model was digitally edited as virtual ESS by performing uncinectomy, ethmoidectomy, antrostomy, and frontal sinusotomy. The following two post‐operative models were prepared: conventional ethmoidectomy with normal superior meatus (ESS model) and ethmoidectomy with superior meatus enlargement (ESS‐SM model). The calculated three‐dimensional nasal geometries were confirmed using virtual endoscopy to ensure that they corresponded to the post‐operative anatomy observed in the clinical setting. Steady‐state, laminar, inspiratory airflow was simulated, and the velocity, streamline, and mass flow rate in the olfactory region were compared among the preoperative and two postoperative models. Results The mean velocity in the olfactory region, number of streamlines bound to the olfactory region, and mass flow rate were higher in the ESS‐SM model than in the other models. Conclusion We successfully used an innovative approach involving virtual ESS, virtual endoscopy, and CFD to assess postoperative outcomes after ESS. It is hypothesized that the increased airflow to the olfactory fossa achieved with ESS‐SM may lead to improved olfactory function; however, further studies are required. Level of Evidence NA. PMID:28894833
Erichsen Andersson, Annette; Petzold, Max; Bergh, Ingrid; Karlsson, Jón; Eriksson, Bengt I; Nilsson, Kerstin
2014-06-01
The importance of laminar airflow systems in operating rooms as protection from surgical site infections has been questioned. The aim of our study was to explore the differences in air contamination rates between displacement ventilation and laminar airflow systems during planned and acute orthopedic implant surgery. A second aim was to compare the influence of the number of people present, the reasons for traffic flow, and the door-opening rates between the 2 systems. Active air sampling and observations were made during 63 orthopedic implant operations. The laminar airflow system resulted in a reduction of 89% in colony forming units in comparison with the displacement system (P < .001). The air samples taken in the preparation rooms showed high levels of bacterial growth (≈ 40 CFU/m(3)). Our study shows that laminar airflow-ventilated operating rooms offer high-quality air during surgery, with very low levels of colony forming units close to the surgical wound. The continuous maintenance of laminar air flow and other technical systems are crucial, because minor failures in complex systems like those in operating rooms can result in a detrimental effect on air quality and jeopardize the safety of patients. The technical ventilation solutions are important, but they do not guarantee clean air, because many other factors, such as the organization of the work and staff behavior, influence air cleanliness. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Phonatory aerodynamics in connected speech.
Gartner-Schmidt, Jackie L; Hirai, Ryoji; Dastolfo, Christina; Rosen, Clark A; Yu, Lan; Gillespie, Amanda I
2015-12-01
1) Present phonatory aerodynamic data for healthy controls (HCs) in connected speech; 2) contrast these findings between HCs and patients with nontreated unilateral vocal fold paralysis (UVFP); 3) present pre- and post-vocal fold augmentation outcomes for patients with UVFP; 4) contrast data from patients with post-operative laryngeal augmentation to HCs. Retrospective, single-blinded. For phase I, 20 HC participants were recruited. For phase II, 20 patients with UVFP were age- and gender-matched to the 20 HC participants used in phase I. For phase III, 20 patients with UVFP represented a pre- and posttreatment cohort. For phase IV, 20 of the HC participants from phase I and 20 of the postoperative UVFP patients from phase III were used for direct comparison. Aerodynamic measures captured from a sample of the Rainbow Passage included: number of breaths, mean phonatory airflow rate, total duration of passage, inspiratory airflow duration, and expiratory airflow duration. The VHI-10 was also obtained pre- and postoperative laryngeal augmentation. All phonatory aerodynamic measures were significantly increased in patients with preoperative UVFP than the HC group. Patients with laryngeal augmentation took significantly less breaths, had less mean phonatory airflow rate during voicing, and had shorter inspiratory airflow duration than the preoperative UVFP group. None of the postoperative measures returned to HC values. Significant improvement in the Voice Handicap Index-10 scores postlaryngeal augmentation was also found. Methodology described in this study improves upon existing aerodynamic voice assessment by capturing characteristics germane to UVFP patient complaints and measuring change before and after laryngeal augmentation in connected speech. 4. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Nonstimulated rabbit phonation model: Cricothyroid approximation.
Novaleski, Carolyn K; Kojima, Tsuyoshi; Chang, Siyuan; Luo, Haoxiang; Valenzuela, Carla V; Rousseau, Bernard
2016-07-01
To describe a nonstimulated in vivo rabbit phonation model using an Isshiki type IV thyroplasty and uninterrupted humidified glottal airflow to produce sustained audible phonation. Prospective animal study. Six New Zealand white breeder rabbits underwent a surgical procedure involving an Isshiki type IV thyroplasty and continuous airflow delivered to the glottis. Phonatory parameters were examined using high-speed laryngeal imaging and acoustic and aerodynamic analysis. Following the procedure, airflow was discontinued, and sutures remained in place to maintain the phonatory glottal configuration for microimaging using a 9.4 Tesla imaging system. High-speed laryngeal imaging revealed sustained vocal fold oscillation throughout the experimental procedure. Analysis of acoustic signals revealed a mean vocal intensity of 61 dB and fundamental frequency of 590 Hz. Aerodynamic analysis revealed a mean airflow rate of 85.91 mL/s and subglottal pressure of 9 cm H2 O. Following the procedure, microimaging revealed that the in vivo phonatory glottal configuration was maintained, providing consistency between the experimental and postexperimental laryngeal geometry. The latter provides a significant milestone that is necessary for geometric reconstruction and to allow for validation of computational simulations against the in vivo rabbit preparation. We demonstrate a nonstimulated in vivo phonation preparation using an Isshiki type IV thyroplasty and continuous humidified glottal airflow in a rabbit animal model. This preparation elicits sustained vocal fold vibration and phonatory measures that are consistent with our laboratory's prior work using direct neuromuscular stimulation for evoked phonation. N/A. Laryngoscope, 126:1589-1594, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke
This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less
Ng, Soo Khai; Kahawita, Shyalle; Andrew, Nicholas Howard; Henderson, Tim; Craig, Jamie Evan; Landers, John
2018-05-01
It is well established from different population-based studies that visual impairment is associated with increased mortality rate. However, to our knowledge, the association of visual impairment with increased mortality rate has not been reported among indigenous Australian individuals. To assess the association between visual impairment and 10-year mortality risk among the remote indigenous Australian population. Prospective cohort study recruiting indigenous Australian individuals from 30 remote communities located within the central Australian statistical local area over a 36-month period between July 2005 and June 2008. The data were analyzed in January 2017. Visual acuity, slitlamp biomicroscopy, and fundus examination were performed on all patients at recruitment. Visual impairment was defined as a visual acuity of less than 6/12 in the better eye. Mortality rate and mortality cause were obtained at 10 years, and statistical analyses were performed. Hazard ratios for 10-year mortality with 95% confidence intervals are presented. One thousand three hundred forty-seven patients were recruited from a total target population number of 2014. The mean (SD) age was 56 (11) years, and 62% were women. The total all-cause mortality was found to be 29.3% at 10 years. This varied from 21.1% among those without visual impairment to 48.5% among those with visual impairment. After adjustment for age, sex, and the presence of diabetes and hypertension, those with visual impairment were 40% more likely to die (hazard ratio, 1.40; 95% CI, 1.16-1.70; P = .001) during the 10-year follow-up period compared with those with normal vision. Bilateral visual impairment among remote indigenous Australian individuals was associated with 40% higher 10-year mortality risk compared with those who were not visually impaired. Resource allocation toward improving visual acuity may therefore aid in closing the gap in mortality outcomes between indigenous and nonindigenous Australian individuals.
NASA Technical Reports Server (NTRS)
Groves, Curtis; Ilie, Marcel; Schallhorn, Paul
2014-01-01
Spacecraft components may be damaged due to airflow produced by Environmental Control Systems (ECS). There are uncertainties and errors associated with using Computational Fluid Dynamics (CFD) to predict the flow field around a spacecraft from the ECS System. This paper describes an approach to estimate the uncertainty in using CFD to predict the airflow speeds around an encapsulated spacecraft.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 89 300 91 4.0 102 (c) The exhalation resistance shall not exceed 25 mm. (1 inch) of water-column... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test, Type A and Type AE supplied-air respirators; minimum requirements. 84.153 Section 84.153 Public Health PUBLIC HEALTH SERVICE...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
... airflow to maintain a clear-vision area. The heavy rain and high speed conditions specified in the current... to maintain a sufficiently clear area of the windshield in low-speed flight or during surface... airflow disturbance or separation on the windshield could cause failure to maintain a clear-vision area on...
Performance assessment of U.S. residential cooking exhaust hoods.
Delp, William W; Singer, Brett C
2012-06-05
This study assessed the performance of seven new residential cooking exhaust hoods representing common U.S. designs. Laboratory tests were conducted to determine fan curves relating airflow to duct static pressure, sound levels, and exhaust gas capture efficiency for front and back cooktop burners and the oven. Airflow rate sensitivity to duct flow resistance was higher for axial fan devices than for centrifugal fan devices. Pollutant capture efficiency (CE) ranged from <15% to >98%, varying across hoods and with airflow and burner position for each hood. CE was higher for back burners relative to front burners, presumably because most hoods covered only part of the front burners. Open hoods had higher CE than those with grease screen and metal-covered bottoms. The device with the highest CE--exceeding 80% for oven and front burners--had a large, open hood that covered most of the front burners. The airflow rate for this hood surpassed the industry-recommended level of 118 L·s(-1) (250 cfm) and produced sound levels too high for normal conversation. For hoods meeting the sound and fan efficacy criteria for Energy Star, CE was <30% for front and oven burners.
Moghadam, Shima Jowhari; Navarro, Laurent; Leclerc, Lara; Hodin, Sophie; Pourchez, Jérémie
2018-07-30
Treating chronic rhinosinusitis (CRS) by nebulization requires an airflow capable to deliver medication to deep target sites beyond the nasal valve. Fixed frequency acoustic airflow technology is currently available, mainly as post-surgical therapy, but still have not been able to realize the full potential of direct nose to paranasal sinuses delivery. Reported herein are the application of frequency sweep acoustic airflow and the optimization of its frequency range, sweep cycle duration and intensity. The resonant frequencies of the model's maxillary sinuses can be estimated using the Helmholtz resonator theory. Results indicated a resonant frequency of 479 Hz for the right maxillary sinus and one of 849 Hz for the left maxillary sinus. The highest intrasinus deposition within the experiments are from sweep cycle duration of 1 s, intensity of 80 dB, and frequency range of 100-850 Hz. The optimal range of frequency determined from experiments is in good agreement with the corresponding frequency range obtained from the Helmholtz resonator theory. Results reveal a significantly enhanced maxillary sinus drug deposition. This technique affords the potential of treating CRS. Copyright © 2018 Elsevier B.V. All rights reserved.
Hair sensor using a photoelectronic principle for sensing airflow and its direction
NASA Astrophysics Data System (ADS)
Huang, Kuang-Yuh; Huang, Chien-Tai
2011-01-01
Many organisms have diverse hair cells to instantaneously perceive the change of surroundings so that they can keep away from threats. These organs can precisely detect the tiny variations of airflow, water flow, sound, or pressure, and also resolve their affecting directions. Through this brilliant inspiration by the insects' cilia, we decided to design and develop a hair sensor for detecting two-dimensional airflow and pressure waves by using photoelectronic principles. The hair sensor inherently consists of an artificial cilium supported by an elastic membrane. A light-emitting diode and a quadrant photodiode are used as the photoelectronic sensor. The airflow or pressure wave directly stimulates the cilium to sway, and this motion contributes to let the projected light beam shift over the quadrant photodiode, whose four photodiodes produce then corresponding output signals. Because of dynamic and high-sensitive properties of the photoelectronic sensor, the hair sensor we developed possesses a high measurement resolution to be able to detect very tiny stimulation and its affecting direction. According to its multifaceted characteristics and simple structure, the hair sensor can be applied in numerous potential application fields, such as intrusion alarm system, noise detection system, as well as a tactile sensor.
Measuring Device for Air Speed in Macroporous Media and Its Application Inside Apple Storage Bins.
Geyer, Martin; Praeger, Ulrike; Truppel, Ingo; Scaar, Holger; Neuwald, Daniel A; Jedermann, Reiner; Gottschalk, Klaus
2018-02-13
In cold storage facilities of fruit and vegetables, airflow is necessary for heat removal. The design of storage facilities influences the air speed in the surrounding of the product. Therefore, knowledge about airflow next to the product is important to plan the layout of cold stores adapted to the requirements of the products. A new sensing device (ASL, Air speed logger) is developed for omnidirectional measurement of air speed between fruit or vegetables inside storage bins or in bulk. It consists of four interconnected plastic spheres with 80 mm diameter each, adapted to the size of apple fruit. In the free space between the spheres, silicon diodes are fixed for the airflow measurement based on a calorimetric principle. Battery and data logger are mounted inside the spheres. The device is calibrated in a wind tunnel in a measuring range of 0-1.3 m/s. Air speed measurements in fruit bulks on laboratory scale and in an industrial fruit store show air speeds in gaps between fruit with high stability at different airflow levels. Several devices can be placed between stored products for determination of the air speed distribution inside bulks or bin stacks in a storage room.
Role of upper airway in ventilatory control in awake and sleeping dogs.
Stradling, J R; England, S J; Harding, R; Kozar, L F; Andrey, S; Phillipson, E A
1987-03-01
We examined the role of the upper airway in the regulation of the pattern of breathing in six adult dogs during wakefulness and sleep. The dogs breathed through a fenestrated endotracheal tube inserted through a tracheostomy. The tube was modified to allow airflow to be directed either through the nose or through the tracheostomy. When airflow was diverted from nose to tracheostomy there was an abrupt increase in the rate of expiratory airflow, resulting in prolongation of the end-expiratory pause but no change in overall expiratory duration or respiratory frequency. Furthermore, electromyogram recordings from implanted diaphragmatic and laryngeal muscle electrodes did not show any changes that could be interpreted as an attempt to delay expiratory airflow or increase end-expiratory lung volume. The effects of switching from nose to tracheostomy breathing could be reversed by adding a resistance to the endotracheal tube so as to approximate upper airway resistance. The findings indicate that under normal conditions in the adult dog upper airway receptors play little role in regulation of respiratory pattern and that the upper airway exerts little influence on the maintenance of end-expiratory lung volume.
Calculation of air movement in ice caves by using the CalcFlow method
NASA Astrophysics Data System (ADS)
Meyer, Christiane; Pflitsch, Andreas; Maggi, Valter
2017-04-01
We present a method to determine the air flow regime within ice caves by temperature loggers. Technical capabilities of conducting airflow measurements are restricted by the availability of energy at the ice cave study sites throughout the year. Though the knowledge of the airflow regime is a prerequisite for the understanding of the cave climate. By cross-correlating different time series of air temperature measurements inside a cave, we define the travel time of the air between the loggers, which corresponds to the time shift of best correlation, and use this result to derive the airflow speed. Then we estimate the temperature biases and scale factors for the temperature variations observed by the different loggers by a least squares adjustment. As quality control for bias and scale we use the formal errors of the estimation process. For the calculated airflow speed quality criteria are developed by use of a simulation study. Furthermore we will apply the method to temperature measurements in the static ice cave Schellenberger Eishöhle (Germany). In the end we show how the method can be used as an advanced filter for the separation of different signal contents of the temperature measurements.
Social and Non-Social Hazard Response in Drivers with Autism Spectrum Disorder
ERIC Educational Resources Information Center
Bishop, Haley Johnson; Biasini, Fred J.; Stavrinos, Despina
2017-01-01
Driving is a complex task that relies on manual, cognitive, visual and social skill. The social demands of driving may be challenging for individuals with Autism Spectrum Disorder (ASD) due to known social impairments. This study investigated how drivers with ASD respond to social (e.g., pedestrians) and non-social (e.g., vehicles) hazards in a…
The response of stationary planetary waves to tropospheric forcing
NASA Technical Reports Server (NTRS)
Alpert, J. C.; Geller, M. A.; Avery, S. K.
1983-01-01
The lower boundary forcing of airflow over topography, and the internal forcing that results from the geographical distribution of diabatic heating, are studied in light of a steady state, linear, quasi-geostrophic model of stationary waves on a sphere. The lower boundary vertical motions forced by airflow over topography depend on whether the horizontal deflection of airflow around topographic features is taken into account, the level of the wind profile at which flow over topography is assumed to take place, and the topographic data set that was used in the forcing formulation. The lower boundary forcing is taken to be given by the observed stationary planetary wave in lower boundary geopotential height, and the internal forcing is computed using the planetary wave propagation equation on the observed wave structure.
Technology development activities for housing research animals on Space Station Freedom
NASA Technical Reports Server (NTRS)
Jenner, Jeffrey W.; Garin, Vladimir M.; Nguyen, Frank D.
1991-01-01
The development and design of animal facilities are described in terms of the technological needs for NASA's Biological Flight Research Laboratory. Animal habitats are presented with illustrations which encompass waste-collection techniques for microgravity conditions that reduce the need for crew participation. The technology is intended to be highly compatible with animal morphology, and airflow is employed as the primary mechanism of waste control. The airflow can be utilized in the form of localized high-speed directed flow that simultaneously provides a clean animal habitat and low airflow rates. The design of an animal-habitat testbed is presented which capitalizes on contamination-control mechanisms and suitable materials for microgravity conditions. The developments in materials and technologies represent significant contributions for the design of the centrifuge facilities for the Space Station Freedom.
NASA Astrophysics Data System (ADS)
Wang, Dianhai; Shi, Chengying; Cai, Xinghui
2018-05-01
In order to analyze the influence of the change of axial position on the performance of labyrinth gear, the Fluent is used to simulate the airflow in the labyrinth in this paper. The leakage coefficient and heat transfer coefficient of the sealing teeth under different axial positions are obtained. The comparisons of results shows that the change of the axial position of the stepped labyrinth seals and the bushing has little effect on the airflow inside the cavity, and the change of axial position has little influence on the leakage coefficient of labyrinth seal; The change in the axial position of the stepped labyrinth seals and the bushing does not lead to a significant effect on the heat transfer characteristics of the airflow and the cavity channel.
Response of Metal Core Piezoelectric Fibers to Unsteady Airflows
NASA Astrophysics Data System (ADS)
Qiu, J. H.; Ji, H. L.; Zhu, K. J.; Park, M. J.
In the previous study, possible applications of metal core piezoelectric fibers with a diameter of 200 to 250 µm as bionic airflow sensors mimicking the flow sensitive receptor hairs of crickets have been proposed. This study aims to investigate the dynamic responses of the metal core piezoelectric fibers to unsteady airflow. The metal core piezoelectric fiber is half coated on the outer surface and is used in the bending mode. Wind tunnel tests were carried out and the output voltage of the fiber under the excitation of the unsteady aerodynamic force during flow acceleration and deceleration was measured when the wind tunnel was suddenly closed or opened by a shutter. The relationship between the maximum voltage and the steady-state velocity and that between the voltage and the acceleration of flow were also obtained.
Innovative method and equipment for personalized ventilation.
Kalmár, F
2015-06-01
At the University of Debrecen, a new method and equipment for personalized ventilation has been developed. This equipment makes it possible to change the airflow direction during operation with a time frequency chosen by the user. The developed office desk with integrated air ducts and control system permits ventilation with 100% outdoor air, 100% recirculated air, or a mix of outdoor and recirculated air in a relative proportion set by the user. It was shown that better comfort can be assured in hot environments if the fresh airflow direction is variable. Analyzing the time step of airflow direction changing, it was found that women prefer smaller time steps and their votes related to thermal comfort sensation are higher than men's votes. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Mitchell, G. A.; Sanders, B. W.
1974-01-01
The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. The inlet stable airflow range provided by various stability-bypass entrance configurations in alternate combination with several stability-bypass exit controls was determined for both steady-state conditions and internal transient pulses. Transient results were also obtained for the inlet with a choke point at the diffuser exit. Instart angles of attack were determined for the various stability-bypass entrance configurations. The response of the inlet-coldpipe system to internal and external oscillating disturbances was determined. Poppet valves at the stability-bypass exit provided an inlet stable airflow range of 28 percent or greater at all static and transient conditions.
NASA Astrophysics Data System (ADS)
Tonini, Roberto; Sandri, Laura; Costa, Antonio; Selva, Jacopo
2014-05-01
Campi Flegrei (CF) is a large volcanic field located west of the Gulf of Naples, characterized by a wide and almost circular caldera which is partially submerged beneath the Gulf of Pozzuoli. It is known that the magma-water interaction is a key element to determine the character of submarine eruptions and their impact on the surrounding areas, but this phenomenon is still not well understood and it is rarely considered in hazard assessment. The aim of the present work is to present a preliminary study of the effect of the sea on the tephra fall hazard from CF on the municipality of Naples, by introducing a variability in the probability of tephra production according to the eruptive scale (defined on the basis of the erupted volume) and the depth of the opening submerged vents. Four different Probabilistic Volcanic Hazard Assessment (PVHA) models have been defined through the application of the model BET_VH at CF, by accounting for different modeling procedures and assumptions for the submerged part of the caldera. In particular, we take into account: 1) the effect of the sea as null, i.e. as if the water were not present; 2) the effect of the sea as a cap that totally blocks the explosivity of eruptions and consequently the tephra production; 3) an ensemble model between the two models described at the previous points 1) and 2); 4) a variable probability of tephra production depending on the depth of the submerged vent. The PVHA models are then input to pyPHaz, a tool developed and designed at INGV to visualize, analyze and merge into ensemble models PVHA's results and, potentially, any other kind of probabilistic hazard assessment, both natural and anthropic, in order to evaluate the importance of considering a variability among subaerial and submerged vents on tephra fallout hazard from CF in Naples. The analysis is preliminary and does not pretend to be exhaustive, but on one hand it represents a starting point for future works; on the other hand, it is a good case study to show the potentiality of the pyPHaz tool that, thanks to a dedicated Graphical User Interface (GUI), allows to interactively manage and visualize results of probabilistic hazards (hazard curves together with probability and hazard maps for different levels of uncertainties), and to compare or merge different hazard models producing ensemble models. This work has been developed in the framework of two Italian projects, "ByMuR (Bayesian Multi-Risk Assessment: a case study for natural risks in the city of Naples)" funded by the Italian Ministry of Education, Universities and Research (MIUR), and "V1: Probabilistic Volcanic Hazard Assessments" funded by the Italian Department of Civil Protection (DPC).
Schumann, Ronald L; Ash, Kevin D; Bowser, Gregg C
2018-02-01
Recent advancements in severe weather detection and warning dissemination technologies have reduced, but not eliminated, large-casualty tornado hazards in the United States. Research on warning cognition and behavioral response by the public has the potential to further reduce tornado-related deaths and injuries; however, less research has been conducted in this area compared to tornado research in the physical sciences. Extant research in this vein tends to bifurcate. One branch of studies derives from classic risk perception, which investigates cognitive, affective, and sociocultural factors in relation to concern and preparation for uncertain risks. Another branch focuses on psychological, social, and cultural factors implicated in warning response for rapid onset hazards, with attention paid to previous experience and message design. Few studies link risk perceptions with cognition and response as elicited by specific examples of warnings. The present study unites risk perception, cognition, and response approaches by testing the contributions of hypothesized warning response drivers in one set of path models. Warning response is approximated by perceived fear and intended protective action as reported by survey respondents when exposed to hypothetical tornado warning scenarios. This study considers the roles of hazard knowledge acquisition, information-seeking behaviors, previous experience, and sociodemographic factors while controlling for the effects of the visual warning graphic. Findings from the study indicate the primacy of a user's visual interpretation of a warning graphic in shaping tornado warning response. Results also suggest that information-seeking habits, previous tornado experience, and local disaster culture play strong influencing roles in warning response. © 2017 Society for Risk Analysis.
3D Building Evacuation Route Modelling and Visualization
NASA Astrophysics Data System (ADS)
Chan, W.; Armenakis, C.
2014-11-01
The most common building evacuation approach currently applied is to have evacuation routes planned prior to these emergency events. These routes are usually the shortest and most practical path from each building room to the closest exit. The problem with this approach is that it is not adaptive. It is not responsively configurable relative to the type, intensity, or location of the emergency risk. Moreover, it does not provide any information to the affected persons or to the emergency responders while not allowing for the review of simulated hazard scenarios and alternative evacuation routes. In this paper we address two main tasks. The first is the modelling of the spatial risk caused by a hazardous event leading to choosing the optimal evacuation route for a set of options. The second is to generate a 3D visual representation of the model output. A multicriteria decision making (MCDM) approach is used to model the risk aiming at finding the optimal evacuation route. This is achieved by using the analytical hierarchy process (AHP) on the criteria describing the different alternative evacuation routes. The best route is then chosen to be the alternative with the least cost. The 3D visual representation of the model displays the building, the surrounding environment, the evacuee's location, the hazard location, the risk areas and the optimal evacuation pathway to the target safety location. The work has been performed using ESRI's ArcGIS. Using the developed models, the user can input the location of the hazard and the location of the evacuee. The system then determines the optimum evacuation route and displays it in 3D.
Automation for System Safety Analysis
NASA Technical Reports Server (NTRS)
Malin, Jane T.; Fleming, Land; Throop, David; Thronesbery, Carroll; Flores, Joshua; Bennett, Ted; Wennberg, Paul
2009-01-01
This presentation describes work to integrate a set of tools to support early model-based analysis of failures and hazards due to system-software interactions. The tools perform and assist analysts in the following tasks: 1) extract model parts from text for architecture and safety/hazard models; 2) combine the parts with library information to develop the models for visualization and analysis; 3) perform graph analysis and simulation to identify and evaluate possible paths from hazard sources to vulnerable entities and functions, in nominal and anomalous system-software configurations and scenarios; and 4) identify resulting candidate scenarios for software integration testing. There has been significant technical progress in model extraction from Orion program text sources, architecture model derivation (components and connections) and documentation of extraction sources. Models have been derived from Internal Interface Requirements Documents (IIRDs) and FMEA documents. Linguistic text processing is used to extract model parts and relationships, and the Aerospace Ontology also aids automated model development from the extracted information. Visualizations of these models assist analysts in requirements overview and in checking consistency and completeness.
Using computer visualizations to help understand how forests change and develop
Brian Orland; Cenk Ursavas
2006-01-01
Probably a first question people ask when they hear about proposed forest management actions to address fire hazard or forest health concerns is "what will the forest look like"? The recent advent of powerful computer visualization tools has provided one means of answering that question. The resultant images can be a powerful tool for communicating the...
Visual Impairments, "Including Blindness." NICHCY Disability Fact Sheet #13
ERIC Educational Resources Information Center
National Dissemination Center for Children with Disabilities, 2012
2012-01-01
Vision is one of the five senses. Being able to see gives tremendous access to learning about the world around--people's faces and the subtleties of expression, what different things look like and how big they are, and the physical environments, including approaching hazards. When a child has a visual impairment, it is cause for immediate…
An Offline-Online Android Application for Hazard Event Mapping Using WebGIS Open Source Technologies
NASA Astrophysics Data System (ADS)
Olyazadeh, Roya; Jaboyedoff, Michel; Sudmeier-Rieux, Karen; Derron, Marc-Henri; Devkota, Sanjaya
2016-04-01
Nowadays, Free and Open Source Software (FOSS) plays an important role in better understanding and managing disaster risk reduction around the world. National and local government, NGOs and other stakeholders are increasingly seeking and producing data on hazards. Most of the hazard event inventories and land use mapping are based on remote sensing data, with little ground truthing, creating difficulties depending on the terrain and accessibility. Open Source WebGIS tools offer an opportunity for quicker and easier ground truthing of critical areas in order to analyse hazard patterns and triggering factors. This study presents a secure mobile-map application for hazard event mapping using Open Source WebGIS technologies such as Postgres database, Postgis, Leaflet, Cordova and Phonegap. The objectives of this prototype are: 1. An Offline-Online android mobile application with advanced Geospatial visualisation; 2. Easy Collection and storage of events information applied services; 3. Centralized data storage with accessibility by all the service (smartphone, standard web browser); 4. Improving data management by using active participation in hazard event mapping and storage. This application has been implemented as a low-cost, rapid and participatory method for recording impacts from hazard events and includes geolocation (GPS data and Internet), visualizing maps with overlay of satellite images, viewing uploaded images and events as cluster points, drawing and adding event information. The data can be recorded in offline (Android device) or online version (all browsers) and consequently uploaded through the server whenever internet is available. All the events and records can be visualized by an administrator and made public after approval. Different user levels can be defined to access the data for communicating the information. This application was tested for landslides in post-earthquake Nepal but can be used for any other type of hazards such as flood, avalanche, etc. Keywords: Offline, Online, WebGIS Open source, Android, Hazard Event Mapping
DaNa L. Carlis; Yi-Leng Chen; Vernon R. Morris
2010-01-01
The fifth-generation Pennsylvania State UniversityâNCAR Mesoscale Model (MM5) coupled with the Noah land surface model (LSM) is employed to simulate island-scale airflow and circulations over Maui County, Hawaii, under summer trade wind conditions, during JulyâAugust 2005. The model forecasts are validated by surface observations with good agreement.
Dispersion of pollutants in densely populated urban areas is a research area of clear importance. Currently, few numerical tools exist capable of describing airflow and dispersion patterns in these complex regions in a time efficient manner. (QUIC), Quick Urban & Industrial C...
Wakayama, Tadashi; Suzuki, Masaaki; Tanuma, Tadashi
2016-01-01
Objective Nasal obstruction is a common problem in continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea and limits treatment compliance. The purpose of this study is to model the effects of nasal obstruction on airflow parameters under CPAP using computational fluid dynamics (CFD), and to clarify quantitatively the relation between airflow velocity and pressure loss coefficient in subjects with and without nasal obstruction. Methods We conducted an observational cross-sectional study of 16 Japanese adult subjects, of whom 9 had nasal obstruction and 7 did not (control group). Three-dimensional reconstructed models of the nasal cavity and nasopharynx with a CPAP mask fitted to the nostrils were created from each subject’s CT scans. The digital models were meshed with tetrahedral cells and stereolithography formats were created. CPAP airflow simulations were conducted using CFD software. Airflow streamlines and velocity contours in the nasal cavities and nasopharynx were compared between groups. Simulation models were confirmed to agree with actual measurements of nasal flow rate and with pressure and flow rate in the CPAP machine. Results Under 10 cmH2O CPAP, average maximum airflow velocity during inspiration was 17.6 ± 5.6 m/s in the nasal obstruction group but only 11.8 ± 1.4 m/s in the control group. The average pressure drop in the nasopharynx relative to inlet static pressure was 2.44 ± 1.41 cmH2O in the nasal obstruction group but only 1.17 ± 0.29 cmH2O in the control group. The nasal obstruction and control groups were clearly separated by a velocity threshold of 13.5 m/s, and pressure loss coefficient threshold of approximately 10.0. In contrast, there was no significant difference in expiratory pressure in the nasopharynx between the groups. Conclusion This is the first CFD analysis of the effect of nasal obstruction on CPAP treatment. A strong correlation between the inspiratory pressure loss coefficient and maximum airflow velocity was found. PMID:26943335
Investigation of induced recirculation during planned ventilation system maintenance
Pritchard, C.J.; Scott, D.F.; Noll, J.D.; Voss, B.; Leonis, D.
2015-01-01
The Office of Mine Safety and Health Research (OMSHR) investigated ways to increase mine airflow to underground metal/nonmetal (M/NM) mine working areas to improve miners’ health and safety. One of those areas is controlled recirculation. Because the quantity of mine air often cannot be increased, reusing part of the ventilating air can be an effective alternative, if implemented properly, until the capacity of the present system is improved. The additional airflow can be used to provide effective dilution of contaminants and higher flow velocities in the underground mine environment. Most applications of controlled recirculation involve taking a portion of the return air and passing it back into the intake to increase the air volume delivered to the desired work areas. OMSHR investigated a Nevada gold mine where shaft rehabilitation was in progress and one of the two main fans was shut down to allow reduced air velocity for safe shaft work. Underground booster fan operating pressures were kept constant to maintain airflow to work areas, inducing controlled recirculation in one work zone. Investigation into system behavior and the effects of recirculation on the working area during times of reduced primary ventilation system airflow would provide additional information on implementation of controlled recirculation into the system and how these events affect M/NM ventilation systems. The National Institute for Occupational Safety and Health monitored the ventilation district when both main fans were operating and another scenario with one of the units turned off for maintenance. Airflow and contaminants were measured to determine the exposure effects of induced recirculation on miner health. Surveys showed that 19% controlled recirculation created no change in the overall district airflow distribution and a small reduction in district fresh air intake. Total dust levels increased only modestly and respirable dust levels were also low. Diesel particulate matter (DPM) levels showed a high increase in district intake mass flow, but minor increases in exposure levels related to the recirculation percentage. Utilization of DPM mass flow rates allows input into ventilation modeling programs to better understand and plan for ventilation changes and district recirculation effects on miners’ health. PMID:26190862
Kotz, Daniel; Wesseling, Geertjan; Huibers, Marcus J H; van Schayck, Onno C P
2007-11-15
The use of spirometry for early detection of chronic obstructive pulmonary disease (COPD) is still an issue of debate, particularly because of a lack of convincing evidence that spirometry has an added positive effect on smoking cessation. We hypothesise that early detection of COPD and confrontation with spirometry for smoking cessation may be effective when applying an approach we have termed "confrontational counselling"; a patient-centred approach which involves specific communication skills and elements of cognitive therapy. An important aspect is to confront the smoker with his/her airflow limitation during the counselling sessions. The primary objective of this study is to test the efficacy of confrontational counselling in comparison to regular health education and promotion for smoking cessation delivered by specialized respiratory nurses in current smokers with previously undiagnosed mild to moderate airflow limitation. The study design is a randomized controlled trial comparing confrontational counselling delivered by a respiratory nurse combined with nortriptyline for smoking cessation (experimental group), health education and promotion delivered by a respiratory nurse combined with nortriptyline for smoking cessation (control group 1), and "care as usual" delivered by the GP (control group 2). Early detection of smokers with mild to moderate airflow limitation is achieved by means of a telephone interview in combination with spirometry. Due to a comparable baseline risk of airflow limitation and motivation to quit smoking, and because of the standardization of number, duration, and scheduling of counselling sessions between the experimental group and control group 1, the study enables to assess the "net" effect of confrontational counselling. The study has been ethically approved and registered. Ethical as well as methodological considerations of the study are discussed in this protocol. A significant and relevant effect of confrontational counselling would provide an argument in favour of early detection of current smokers with airflow limitation. Successful treatment of tobacco dependence in respiratory patients requires repeated intensive interventions. The results of this study may also show that respiratory nurses are able to deliver this treatment and that intensive smoking cessation counselling is more feasible. : Netherlands Trial Register (ISRCTN 64481813).
NASA Technical Reports Server (NTRS)
1993-01-01
The Biomedical Optical Company of America's Eagle 475 lens absorbs 100 percent of all photowavelengths considered hazardous to eye tissue, including ultraviolet and blue light, which are considered contributors to cataract and age-related macular degeneration. The lens absorbs hazardous wavelengths, but allows a higher percentage of visually useful areas of the spectrum to pass through. Polarization blocks out irritating glint and glare and heightens visual acuity. The Eagle 475 sunglasses are the latest in a series of spinoffs that originated at the Jet Propulsion Laboratory where two scientists developed a protective, welding curtain that filtered out harmful irradiance. The result was a commercial curtain that absorbs filters and scatters light, providing protection for personnel in welding areas. Further research focused on protective industrial glasses and later on consumer products.
Cleared for the visual approach: Human factor problems in air carrier operations
NASA Technical Reports Server (NTRS)
Monan, W. P.
1983-01-01
The study described herein, a set of 353 ASRS reports of unique aviation occurrences significantly involving visual approaches was examined to identify hazards and pitfalls embedded in the visual approach procedure and to consider operational practices that might help avoid future mishaps. Analysis of the report set identified nine aspects of the visual approach procedure that appeared to be predisposing conditions for inducing or exacerbating the effects of operational errors by flight crew members or controllers. Predisposing conditions, errors, and operational consequences of the errors are discussed. In a summary, operational policies that might mitigate the problems are examined.
Inflammatory Biomarkers Predict Airflow Obstruction After Exposure to World Trade Center Dust
Nolan, Anna; Naveed, Bushra; Comfort, Ashley L.; Ferrier, Natalia; Hall, Charles B.; Kwon, Sophia; Kasturiarachchi, Kusali J.; Cohen, Hillel W.; Zeig-Owens, Rachel; Glaser, Michelle S.; Webber, Mayris P.; Aldrich, Thomas K.; Rom, William N.; Kelly, Kerry; Prezant, David J.
2012-01-01
Background: The World Trade Center (WTC) collapse on September 11, 2001, produced airflow obstruction in a majority of firefighters receiving subspecialty pulmonary evaluation (SPE) within 6.5 years post-September 11, 2001. Methods: In a cohort of 801 never smokers with normal pre-September 11, 2001, FEV1, we correlated inflammatory biomarkers and CBC counts at monitoring entry within 6 months of September 11, 2001, with a median FEV1 at SPE (34 months; interquartile range, 25-57). Cases of airflow obstruction had FEV1 less than the lower limit of normal (LLN) (100 of 801; 70 of 100 had serum), whereas control subjects had FEV1 greater than or equal to LLN (153 of 801; 124 of 153 had serum). Results: From monitoring entry to SPE years later, FEV1 declined 12% in cases and increased 3% in control subjects. Case subjects had elevated serum macrophage derived chemokine (MDC), granulocyte-macrophage colony-stimulating factor (GM-CSF), granulocyte colony-stimulating factor, and interferon inducible protein-10 levels. Elevated GM-CSF and MDC increased the risk for subsequent FEV1 less than LLN by 2.5-fold (95% CI, 1.2-5.3) and 3.0-fold (95% CI, 1.4-6.1) in a logistic model adjusted for exposure, BMI, age on September 11, 2001, and polymorphonuclear neutrophils. The model had sensitivity of 38% (95% CI, 27-51) and specificity of 88% (95% CI, 80-93). Conclusions: Inflammatory biomarkers can be risk factors for airflow obstruction following dust and smoke exposure. Elevated serum GM-CSF and MDC levels soon after WTC exposure were associated with increased risk of airflow obstruction in subsequent years. Biomarkers of inflammation may help identify pathways producing obstruction after irritant exposure. PMID:21998260
Borojeni, Azadeh A.T.; Frank-Ito, Dennis O.; Kimbell, Julia S.; Rhee, John S.; Garcia, Guilherme J. M.
2016-01-01
Virtual surgery planning based on computational fluid dynamics (CFD) simulations has the potential to improve surgical outcomes for nasal airway obstruction (NAO) patients, but the benefits of virtual surgery planning must outweigh the risks of radiation exposure. Cone beam computed tomography (CBCT) scans represent an attractive imaging modality for virtual surgery planning due to lower costs and lower radiation exposures compared with conventional CT scans. However, to minimize the radiation exposure, the CBCT sinusitis protocol sometimes images only the nasal cavity, excluding the nasopharynx. The goal of this study was to develop an idealized nasopharynx geometry for accurate representation of outlet boundary conditions when the nasopharynx geometry is unavailable. Anatomically-accurate models of the nasopharynx created from thirty CT scans were intersected with planes rotated at different angles to obtain an average geometry. Cross sections of the idealized nasopharynx were approximated as ellipses with cross-sectional areas and aspect ratios equal to the average in the actual patient-specific models. CFD simulations were performed to investigate whether nasal airflow patterns were affected when the CT-based nasopharynx was replaced by the idealized nasopharynx in 10 NAO patients. Despite the simple form of the idealized geometry, all biophysical variables (nasal resistance, airflow rate, and heat fluxes) were very similar in the idealized vs. patient-specific models. The results confirmed the expectation that the nasopharynx geometry has a minimal effect in the nasal airflow patterns during inspiration. The idealized nasopharynx geometry will be useful in future CFD studies of nasal airflow based on medical images that exclude the nasopharynx. PMID:27525807
Clinical characterization of children with resistant airflow obstruction, a multicenter study.
Krishnan, Sankaran; Dozor, Allen J; Bacharier, Leonard; Lang, Jason E; Irvin, Charles G; Kaminsky, David; Farber, Harold J; Gerald, Lynn; Brown, Mark; Holbrook, Janet T; Wise, Robert A; Ryu, Julie; Bose, Sonali; Yasin, Razan; Saams, Joy; Henderson, Robert J; Teague, William G
2018-05-17
To characterize a cohort of children with airflow limitation resistant to bronchodilator (BD) therapy. Pulmonary function tests performed in children 6-17 years of age at 15 centers in a clinical research consortium were screened for resistant airflow limitation, defined as a post-BD FEV 1 and/or an FEV 1 /FVC less than the lower limits of normal. Demographic and clinical data were analyzed for associations with pulmonary function. 582 children were identified. Median age was 13 years (IQR: 11, 16), 60% were males; 62% were Caucasian, 28% were African-American; 19% were obese; 32% were born prematurely and 21% exposed to second hand smoke. Pulmonary diagnoses included asthma (93%), prior significant pneumonia (28%), and bronchiectasis (5%). 65% reported allergic rhinitis, and 11% chronic sinusitis. Subjects without a history of asthma had significantly lower post-BD FEV 1 % predicted (p = 0.008). Subjects without allergic rhinitis had lower post-BD FEV 1 % predicted (p = 0.003). Children with allergic rhinitis, male sex, obesity and Black race had better pulmonary function post-BD. There was lower pulmonary function in children after age 11 years without a history of allergic rhinitis, as compared to those with a history of allergic rhinitis. The most prevalent diagnosis in children with BD-resistant airflow limitation is asthma. Allergic rhinitis and premature birth are common co-morbidities. Children without a history of asthma, as well as those with asthma but no allergic rhinitis, had lower pulmonary function. Children with BD-resistant airflow limitation may represent a sub-group of children with persistent obstruction and high risk for life-long airway disease.
2012-01-01
The purpose of this study was to investigate the aerosolization of particles (micro- and macroconidia and fragments) from Botrytis cinerea cultures in relation to potential human inhalation in indoor environments. The influence of the following factors on the aerosolization of B. cinerea particles was studied: exposure to airflow, relative humidity (rh), changing rh, and plant or building materials. The aerodynamic diameter (da) and the respirable fraction of the aerosolized particles were determined. Conidia and fragments of B. cinerea were not aerosolized as a response to a decrease in the rh. In contrast, both micro- and macroconidia and fungal fragments were aerosolized when exposed to an airflow of 1.5 m s−1 or 0.5 m s−1. Significantly more particles of microconidial size and fragment size were aerosolized at a low rh (18 to 40% rh) than at a higher rh (60 to 80% rh) when cultures were exposed to airflow. The size of the respirable fraction of the aerosolized particles was dependent on the rh but not on the growth material. At high rh, about 30% of the aerosolized particles were of respirable size, while at low rh, about 70% were of respirable size. During low rh, more fungal (1→3)-β-d-glucan and chitinase were aerosolized than during high rh. In conclusion, exposure to external physical forces such as airflow is necessary for the aerosolization of particles from B. cinerea. The amount and size distribution are highly affected by the rh, and more particles of respirable sizes were aerosolized at low rh than at high rh. PMID:22447608
Advances in sublimation studies for particles of explosives
NASA Astrophysics Data System (ADS)
Furstenberg, Robert; Nguyen, Viet; Fischer, Thomas; Abrishami, Tara; Papantonakis, Michael; Kendziora, Chris; Mott, David R.; McGill, R. Andrew
2015-05-01
When handling explosives, or related surfaces, the hands routinely become contaminated with particles of explosives and related materials. Subsequent contact with a solid surface results in particle crushing and deposition. These particles provide an evidentiary trail which is useful for security applications. As such, the opto-physico-chemical characteristics of these particles are critical to trace explosives detection applications in DOD or DHS arenas. As the persistence of these particles is vital to their forensic exploitation, it is important to understand which factors influence their persistence. The longevity or stability of explosives particles on a substrate is a function of several environmental parameters or particle properties including: Vapor pressure, particle geometry, airflow, particle field size, substrate topography, humidity, reactivity, adlayers, admixtures, particle areal density, and temperature. In this work we deposited particles of 2,4-dinitrotoluene on standard microscopy glass slides by particle sieving and studied their sublimation as a function of airflow velocity, areal particle density and particle field size. Analysis of 2D microscopic images was used to compute and track particle size and geometrical characteristics. The humidity, temperature and substrate type were kept constant for each experiment. A custom airflow cell, using standard microscopy glass slide, allowed in-situ photomicroscopy. Areal particle densities and airflow velocities were selected to provide relevant loadings and flow velocities for a range of potential applications. For a chemical of interest, we define the radial sublimation velocity (RSV) for the equivalent sphere of a particle as the parameter to characterize the sublimation rate. The RSV is a useful parameter because it is independent of particle size. The sublimation rate for an ensemble of particles was found to significantly depend on airflow velocity, the areal density of the particles, and the particle field size. To compare sublimation studies these parameters must be known.
Genome-Wide Association Studies Identify CHRNA5/3 and HTR4 in the Development of Airflow Obstruction
Shrine, Nick R. G.; Loehr, Laura R.; Zhao, Jing Hua; Manichaikul, Ani; Lopez, Lorna M.; Smith, Albert Vernon; Heckbert, Susan R.; Smolonska, Joanna; Tang, Wenbo; Loth, Daan W.; Curjuric, Ivan; Hui, Jennie; Latourelle, Jeanne C.; Henry, Amanda P.; Aldrich, Melinda; Bakke, Per; Beaty, Terri H.; Bentley, Amy R.; Borecki, Ingrid B.; Brusselle, Guy G.; Burkart, Kristin M.; Chen, Ting-hsu; Couper, David; Crapo, James D.; Davies, Gail; Dupuis, Josée; Franceschini, Nora; Gulsvik, Amund; Hancock, Dana B.; Harris, Tamara B.; Hofman, Albert; Imboden, Medea; James, Alan L.; Khaw, Kay-Tee; Lahousse, Lies; Launer, Lenore J.; Litonjua, Augusto; Liu, Yongmei; Lohman, Kurt K.; Lomas, David A.; Lumley, Thomas; Marciante, Kristin D.; McArdle, Wendy L.; Meibohm, Bernd; Morrison, Alanna C.; Musk, Arthur W.; Myers, Richard H.; North, Kari E.; Postma, Dirkje S.; Psaty, Bruce M.; Rich, Stephen S.; Rivadeneira, Fernando; Rochat, Thierry; Rotter, Jerome I.; Artigas, María Soler; Starr, John M.; Uitterlinden, André G.; Wareham, Nicholas J.; Wijmenga, Cisca; Zanen, Pieter; Province, Michael A.; Silverman, Edwin K.; Deary, Ian J.; Palmer, Lyle J.; Cassano, Patricia A.; Gudnason, Vilmundur; Barr, R. Graham; Loos, Ruth J. F.; Strachan, David P.; London, Stephanie J.; Boezen, H. Marike; Probst-Hensch, Nicole; Gharib, Sina A.; Hall, Ian P.; O’Connor, George T.; Tobin, Martin D.; Stricker, Bruno H.
2012-01-01
Rationale: Genome-wide association studies (GWAS) have identified loci influencing lung function, but fewer genes influencing chronic obstructive pulmonary disease (COPD) are known. Objectives: Perform meta-analyses of GWAS for airflow obstruction, a key pathophysiologic characteristic of COPD assessed by spirometry, in population-based cohorts examining all participants, ever smokers, never smokers, asthma-free participants, and more severe cases. Methods: Fifteen cohorts were studied for discovery (3,368 affected; 29,507 unaffected), and a population-based family study and a meta-analysis of case-control studies were used for replication and regional follow-up (3,837 cases; 4,479 control subjects). Airflow obstruction was defined as FEV1 and its ratio to FVC (FEV1/FVC) both less than their respective lower limits of normal as determined by published reference equations. Measurements and Main Results: The discovery meta-analyses identified one region on chromosome 15q25.1 meeting genome-wide significance in ever smokers that includes AGPHD1, IREB2, and CHRNA5/CHRNA3 genes. The region was also modestly associated among never smokers. Gene expression studies confirmed the presence of CHRNA5/3 in lung, airway smooth muscle, and bronchial epithelial cells. A single-nucleotide polymorphism in HTR4, a gene previously related to FEV1/FVC, achieved genome-wide statistical significance in combined meta-analysis. Top single-nucleotide polymorphisms in ADAM19, RARB, PPAP2B, and ADAMTS19 were nominally replicated in the COPD meta-analysis. Conclusions: These results suggest an important role for the CHRNA5/3 region as a genetic risk factor for airflow obstruction that may be independent of smoking and implicate the HTR4 gene in the etiology of airflow obstruction. PMID:22837378
NASA Astrophysics Data System (ADS)
Lynch, K.; Jackson, D.; Delgado-Fernandez, I.; Cooper, J. A.; Baas, A. C.; Beyers, M.
2010-12-01
This study examines sand transport and wind speed across a beach at Magilligan Strand, Northern Ireland, under offshore wind conditions. Traditionally the offshore component of local wind regimes has been ignored when quantifying beach-dune sediment budgets, with the sheltering effect of the foredune assumed to prohibit grain entrainment on the adjoining beach. Recent investigations of secondary airflow patterns over coastal dunes have suggested this may not be the case, that the turbulent nature of the airflow in these zones enhances sediment transport potential. Beach sediment may be delivered to the dune toe by re-circulating eddies under offshore winds in coastal areas, which may explain much of the dynamics of aeolian dunes on coasts where the dominant wind direction is offshore. The present study investigated aeolian sediment transport patterns under an offshore wind event. Empirical data were collected using load cell traps, for aeolian sediment transport, co-located with 3-D ultrasonic anemometers. The instrument positioning on the sub-aerial beach was informed by prior analysis of the airflow patterns using computational fluid dynamics. The array covered a total beach area of 90 m alongshore by 65 m cross-shore from the dune crest. Results confirm that sediment transport occurred in the ‘sheltered’ area under offshore winds. Over short time and space scales the nature of the transport is highly complex; however, preferential zones for sand entrainment may be identified. Alongshore spatial heterogeneity of sediment transport seems to show a relationship to undulations in the dune crest, while temporal and spatial variations may also be related to the position of the airflow reattachment zone. These results highlight the important feedbacks between flow characteristics and transport in a complex three dimensional surface.
Cheng, Y; Lin, Z
2015-12-01
The motivation of this study is stimulated by a lack of knowledge about the difference of airflow characteristics between a novel air distribution method [i.e., stratum ventilation (SV)] and conventional air distribution methods [i.e., mixing ventilation (MV) and displacement ventilation (DV)]. Detailed air velocity and temperature measurements were conducted in the occupied zone of a classroom with dimensions of 8.8 m (L) × 6.1 m (W) × 2.4 m (H). Turbulence intensity and power spectrum of velocity fluctuation were calculated using the measured data. Thermal comfort and cooling efficiency were also compared. The results show that in the occupied zone, the airflow characteristics among MV, DV, and SV are different. The turbulent airflow fluctuation is enhanced in this classroom with multiple thermal manikins due to thermal buoyancy and airflow mixing effect. Thermal comfort evaluations indicate that in comparison with MV and DV, a higher supply air temperature should be adopted for SV to achieve general thermal comfort with low draft risk. Comparison of the mean air temperatures in the occupied zone reveals that SV is of highest cooling efficiency, followed by DV and then MV. This study reports the unique profiles of flow, temperature, turbulence intensity, and power spectrum of stratum ventilation, which can have a number of implications for both knowledge and understanding of the flow characteristics in a stratum-ventilated room. With respect to the former, it expounds the fundamental characteristics of this air distribution method; and with respect to the latter, it reveals the mechanism of thermal comfort and energy saving under stratum ventilation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Harris, B A; Andrews, P J D; Murray, G D
2007-01-01
Heat loss from the upper airways and through the skull are physiological mechanisms of brain cooling which have not been fully explored clinically. This randomized, crossover, factorial trial in 12 brain-injured, orally intubated patients investigated the effect of enhanced nasal airflow (high flow unhumidified air with 20 p.p.m. nitric oxide gas) and bilateral head fanning on frontal lobe brain temperature and selective brain cooling. After a 30 min baseline, each patient received the four possible combinations of the interventions--airflow, fanning, both together, no intervention--in randomized order. Each combination was delivered for 30 min and followed by a 30 min washout, the last 5 min of which provided the baseline for the next intervention. The difference in mean brain temperature over the last 5 min of the preceding washout minus the mean over the last 5 min of intervention, was 0.15 degrees C with nasal airflow (P=0.001, 95% CI 0.06-0.23 degrees C) and 0.26 degrees C with head fanning (P<0.001, 95% CI 0.17-0.34 degrees C). The estimate of the combined effect of airflow and fanning on brain temperature was 0.41 degrees C. Selective brain cooling did not occur. Physiologically, this study demonstrates that heat loss through the upper airways and through the skull can reduce parenchymal brain temperature in brain-injured humans and the onset of temperature reduction is rapid. Clinically, in ischaemic stroke, a temperature decrease of 0.27 degrees C may reduce the relative risk of poor outcome by 10-20%. Head fanning may have the potential to achieve a temperature decrease of this order.
Glottal Adduction and Subglottal Pressure in Singing.
Herbst, Christian T; Hess, Markus; Müller, Frank; Švec, Jan G; Sundberg, Johan
2015-07-01
Previous research suggests that independent variation of vocal loudness and glottal configuration (type and degree of vocal fold adduction) does not occur in untrained speech production. This study investigated whether these factors can be varied independently in trained singing and how subglottal pressure is related to average glottal airflow, voice source properties, and sound level under these conditions. A classically trained baritone produced sustained phonations on the endoscopic vowel [i:] at pitch D4 (approximately 294 Hz), exclusively varying either (a) vocal register; (b) phonation type (from "breathy" to "pressed" via cartilaginous adduction); or (c) vocal loudness, while keeping the others constant. Phonation was documented by simultaneous recording of videokymographic, electroglottographic, airflow and voice source data, and by percutaneous measurement of relative subglottal pressure. Register shifts were clearly marked in the electroglottographic wavegram display. Compared with chest register, falsetto was produced with greater pulse amplitude of the glottal flow, H1-H2, mean airflow, and with lower maximum flow declination rate (MFDR), subglottal pressure, and sound pressure. Shifts of phonation type (breathy/flow/neutral/pressed) induced comparable systematic changes. Increase of vocal loudness resulted in increased subglottal pressure, average flow, sound pressure, MFDR, glottal flow pulse amplitude, and H1-H2. When changing either vocal register or phonation type, subglottal pressure and mean airflow showed an inverse relationship, that is, variation of glottal flow resistance. The direct relation between subglottal pressure and airflow when varying only vocal loudness demonstrated independent control of vocal loudness and glottal configuration. Achieving such independent control of phonatory control parameters would be an important target in vocal pedagogy and in voice therapy. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Quality of life in smokers: focus on functional limitations rather than on lung function?
Geijer, Roeland MM; Sachs, Alfred PE; Verheij, Theo JM; Kerstjens, Huib AM; Kuyvenhoven, Marijke M; Hoes, Arno W
2007-01-01
Background The Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification of severity of chronic obstructive pulmonary disease (COPD) is based solely on obstruction and does not capture physical functioning. The hypothesis that the Medical Research Council (MRC) dyspnoea scale would correlate better with quality of life than the level of airflow limitation was examined. Aim To study the associations between quality of life in smokers and limitations in physical functioning (MRC dyspnoea scale) and, quality of life and airflow limitation (GOLD COPD stages). Design Cross-sectional study. Setting The city of IJsselstein, a small town in the centre of The Netherlands. Method Male smokers aged 40–65 years without a prior diagnosis of COPD and enlisted with a general practice, participated in this study. Quality of life was assessed by means of a generic (SF–36) and a disease-specific, questionnaire (QOLRIQ). Results A total of 395 subjects (mean age 55.4 years, pack years 27.1) performed adequate spirometry and completed the questionnaires. Limitations of physical functioning according to the MRC dyspnoea scale were found in 25.1 % (99/395) of the participants and airflow limitation in 40.2% (159/395). The correlations of limitations of physical functioning with all quality-of-life components were stronger than the correlations of all quality-of-life subscales with the severity of airflow limitation. Conclusion In middle-aged smokers the correlation of limitations of physical functioning (MRC dyspnoea scale) with quality of life was stronger than the correlation of the severity of airflow limitation with quality of life. Future staging systems of severity of COPD should capture this and not rely on forced expiratory volume in one second (FEV1) alone. PMID:17550673
Occupational Health and the Arts.
Hinkamp, David L; McCann, Michael; Babin, Angela
2017-09-01
Work in the visual arts, performing arts, and writing can involve exposures to occupational hazards, including hazardous materials, equipment, and conditions, but few art workplaces have strong occupational health resources. Literature searches were conducted for articles that illustrate these concerns. Medical databases were searched for art-related health articles. Other sources were also reviewed, including, unindexed art-health publications, and popular press articles. Information was located that described some exposed populations, art-related hazards, and resulting disorders. Anecdotal reports were used when more complete data were not available. Health hazards in the arts are significant. Occupational health professionals are familiar with most of these concerns and understand their treatment and prevention. The occupational health approach can reduce the health hazards encountered by at-risk art workers. Additional research would benefit these efforts. Resources for further information are available.
Berck, B
1975-05-01
The new research reported herein was motivated by variations in distribution-persistence patterns of fumigant residues (BERCK, 1974). The current developmental program is still underway. In the meantime, measurement of picoliter amounts of SF6 in air by GC equipped with a Ni63 EC detector has been proven useful over an airflow range of 10(-4) to 50 mph, representing a factor of 500,000 in differences in air velocity. Diverse applications have been outlined herein. This is the first case on record where measurement of unassisted airflow in the interstitial air of stored grain has been successfully executed, and which enabled determination of airflow speeds in the range of 0.5 to 7.5 times 10(-4) mph (=3 to 45 inches per hour).
Effects of oblique air flow on burning rates of square ethanol pool fires.
Tao, Changfa; He, Yaping; Li, Yuan; Wang, Xishi
2013-09-15
The effects of downward airflow on the burning rate and/or burning intensity of square alcohol pool fires for different airflow speeds and directions have been studied experimentally in an inclined wind tunnel. An interesting flame-wrapping phenomenon, caused by impingement of air flow, was observed. The mass burning intensity was found to increase with the airflow speed and the impinging angle. The fuel pan rim temperatures were also measured to study the effect of wind direction and speed on heat transfer from the flame to the fuel source. A model based on heat transfer analysis was developed to correlate the burning intensity with the pan rim characteristic temperature. A good correlation was established between the model results and the experimental results. Copyright © 2013 Elsevier B.V. All rights reserved.
Vlakveld, Willem; Romoser, Matthew R. E.; Mehranian, Hasmik; Diete, Frank; Pollatsek, Alexander; Fisher, Donald L.
2012-01-01
Young drivers (younger than 25 years of age) are overrepresented in crashes. Research suggests that a relevant cause is inadequate visual search for possible hazards that are hidden from view. The objective of this study was to develop and evaluate a low-cost, fixed-base simulator training program that would address this failure. It was hypothesized that elicited crashes in the simulator training would result in better scanning for latent hazards in scenarios that were similar to the training scenarios but situated in a different environment (near transfer), and, to a lesser degree, would result in better scanning in scenarios that had altogether different latent hazards than those contained in the training scenarios (far transfer). To test the hypotheses, 18 trained and 18 untrained young novice drivers were evaluated on an advanced driving simulator (different from the training simulator). The eye movements of both groups were measured. In near transfer scenarios, trained drivers fixated the hazardous region 84% of the time, compared with only 57% of untrained drivers. In far transfer scenarios, trained drivers fixated the hazardous region 71 % of the time, compared with only 53% of untrained drivers. The differences between trained and untrained drivers in both the near transfer scenarios and the far transfer scenarios were significant, with a large effect size in the near transfer scenarios and a medium effect size in the far transfer scenarios [respectively: U = 63.00, p(2-tailed) < .01, r = −.53, and U = 88.00, p(2-tailed)<.05,r = −.39]. PMID:23082041
Erikson, Li; Barnard, Patrick; O'Neill, Andrea; Wood, Nathan J.; Jones, Jeanne M.; Finzi Hart, Juliette; Vitousek, Sean; Limber, Patrick; Hayden, Maya; Fitzgibbon, Michael; Lovering, Jessica; Foxgrover, Amy C.
2018-01-01
This paper is the second of two that describes the Coastal Storm Modeling System (CoSMoS) approach for quantifying physical hazards and socio-economic hazard exposure in coastal zones affected by sea-level rise and changing coastal storms. The modelling approach, presented in Part 1, downscales atmospheric global-scale projections to local scale coastal flood impacts by deterministically computing the combined hazards of sea-level rise, waves, storm surges, astronomic tides, fluvial discharges, and changes in shoreline positions. The method is demonstrated through an application to Southern California, United States, where the shoreline is a mix of bluffs, beaches, highly managed coastal communities, and infrastructure of high economic value. Results show that inclusion of 100-year projected coastal storms will increase flooding by 9–350% (an additional average 53.0 ± 16.0 km2) in addition to a 25–500 cm sea-level rise. The greater flooding extents translate to a 55–110% increase in residential impact and a 40–90% increase in building replacement costs. To communicate hazards and ranges in socio-economic exposures to these hazards, a set of tools were collaboratively designed and tested with stakeholders and policy makers; these tools consist of two web-based mapping and analytic applications as well as virtual reality visualizations. To reach a larger audience and enhance usability of the data, outreach and engagement included workshop-style trainings for targeted end-users and innovative applications of the virtual reality visualizations.
Using a 3D CAD plant model to simplify process hazard reviews
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tolpa, G.
A Hazard and Operability (HAZOP) review is a formal predictive procedure used to identify potential hazard and operability problems associated with certain processes and facilities. The HAZOP procedure takes place several times during the life cycle of the facility. Replacing plastic models, layout and detail drawings with a 3D CAD electronic model, provides access to process safety information and a detailed level of plant topology that approaches the visualization capability of the imagination. This paper describes the process that is used for adding the use of a 3D CAD model to flowsheets and proven computer programs for the conduct ofmore » hazard and operability reviews. Using flowsheets and study nodes as a road map for the review the need for layout and other detail drawings is all but eliminated. Using the 3D CAD model again for a post-P and ID HAZOP supports conformance to layout and safety requirements, provides superior visualization of the plant configuration and preserves the owners equity in the design. The response from the review teams are overwhelmingly in favor of this type of review over a review that uses only drawings. Over the long term the plant model serves more than just process hazards analysis. Ongoing use of the model can satisfy the required access to process safety information, OHSA documentation and other legal requirements. In this paper extensive instructions address the logic for the process hazards analysis and the preparation required to assist anyone who wishes to add the use of a 3D model to their review.« less
Evolution of vulnerability of communities facing repeated hazards
Guikema, Seth D.; Zhu, Laiyin; Igusa, Takeru
2017-01-01
The decisions that individuals make when recovering from and adapting to repeated hazards affect a region’s vulnerability in future hazards. As such, community vulnerability is not a static property but rather a dynamic property dependent on behavioral responses to repeated hazards and damage. This paper is the first of its kind to build a framework that addresses the complex interactions between repeated hazards, regional damage, mitigation decisions, and community vulnerability. The framework enables researchers and regional planners to visualize and quantify how a community could evolve over time in response to repeated hazards under various behavioral scenarios. An illustrative example using parcel-level data from Anne Arundel County, Maryland—a county that experiences fairly frequent hurricanes—is presented to illustrate the methodology and to demonstrate how the interplay between individual choices and regional vulnerability is affected by the region’s hurricane experience. PMID:28953893
Occupational hazard evaluation model underground coal mine based on unascertained measurement theory
NASA Astrophysics Data System (ADS)
Deng, Quanlong; Jiang, Zhongan; Sun, Yaru; Peng, Ya
2017-05-01
In order to study how to comprehensively evaluate the influence of several occupational hazard on miners’ physical and mental health, based on unascertained measurement theory, occupational hazard evaluation indicator system was established to make quantitative and qualitative analysis. Determining every indicator weight by information entropy and estimating the occupational hazard level by credible degree recognition criteria, the evaluation model was programmed by Visual Basic, applying the evaluation model to occupational hazard comprehensive evaluation of six posts under a coal mine, and the occupational hazard degree was graded, the evaluation results are consistent with actual situation. The results show that dust and noise is most obvious among the coal mine occupational hazard factors. Excavation face support workers are most affected, secondly, heading machine drivers, coal cutter drivers, coalface move support workers, the occupational hazard degree of these four types workers is II mild level. The occupational hazard degree of ventilation workers and safety inspection workers is I level. The evaluation model could evaluate underground coal mine objectively and accurately, and can be employed to the actual engineering.
VOLCWORKS: A suite for optimization of hazards mapping
NASA Astrophysics Data System (ADS)
Delgado Granados, H.; Ramírez Guzmán, R.; Villareal Benítez, J. L.; García Sánchez, T.
2012-04-01
Making hazards maps is a process linking basic science, applied science and engineering for the benefit of the society. The methodologies for hazards maps' construction have evolved enormously together with the tools that allow the forecasting of the behavior of the materials produced by different eruptive processes. However, in spite of the development of tools and evolution of methodologies, the utility of hazards maps has not changed: prevention and mitigation of volcanic disasters. Integration of different tools for simulation of different processes for a single volcano is a challenge to be solved using software tools including processing, simulation and visualization techniques, and data structures in order to build up a suit that helps in the construction process starting from the integration of the geological data, simulations and simplification of the output to design a hazards/scenario map. Scientific visualization is a powerful tool to explore and gain insight into complex data from instruments and simulations. The workflow from data collection, quality control and preparation for simulations, to achieve visual and appropriate presentation is a process that is usually disconnected, using in most of the cases different applications for each of the needed processes, because it requires many tools that are not built for the solution of a specific problem, or were developed by research groups to solve particular tasks, but disconnected. In volcanology, due to its complexity, groups typically examine only one aspect of the phenomenon: ash dispersal, laharic flows, pyroclastic flows, lava flows, and ballistic projectile ejection, among others. However, when studying the hazards associated to the activity of a volcano, it is important to analyze all the processes comprehensively, especially for communication of results to the end users: decision makers and planners. In order to solve this problem and connect different parts of a workflow we are developing the suite VOLCWORKS, whose principle is to have a flexible-implementation architecture allowing rapid development of software to the extent specified by the needs including calculations, routines, or algorithms, both new and through redesign of available software in the volcanological community, but especially allowing to include new knowledge, models or software transferring them to software modules. The design is component-oriented platform, which allows incorporating particular solutions (routines, simulations, etc.), which can be concatenated for integration or highlighting information. The platform includes a graphical interface with capabilities for working in different visual environments that can be focused to the particular work of different types of users (researchers, lecturers, students, etc.). This platform aims to integrate simulation and visualization phases, incorporating proven tools (now isolated). VOLCWORKS can be used under different operating systems (Windows, Linux and Mac OS) and fit the context of use automatically and at runtime: in both tasks and their sequence, such as utilization of hardware resources (CPU, GPU, special monitors, etc.). The application has the ability to run on a laptop or even in a virtual reality room with access to supercomputers.
MR imaging of apparent 3He gas transport in narrow pipes and rodent airways
NASA Astrophysics Data System (ADS)
Minard, Kevin R.; Jacob, Richard E.; Laicher, Gernot; Einstein, Daniel R.; Kuprat, Andrew P.; Corley, Richard A.
2008-10-01
High sensitivity makes hyperpolarized 3He an attractive signal source for visualizing gas flow with magnetic resonance (MR) imaging. Its rapid Brownian motion, however, can blur observed flow lamina and alter measured diffusion rates when excited nuclei traverse shear-induced velocity gradients during data acquisition. Here, both effects are described analytically, and predicted values for measured transport during laminar flow through a straight, 3.2-mm diameter pipe are validated using two-dimensional (2D) constant-time images of different binary gas mixtures. Results show explicitly how measured transport in narrow conduits is characterized by apparent values that depend on underlying gas dynamics and imaging time. In ventilated rats, this is found to obscure acquired airflow images. Nevertheless, flow splitting at airway branches is still evident and use of 3D vector flow mapping is shown to reveal surprising detail that highlights the correlation between gas dynamics and lung structure.
2014-01-01
normal and three different obstructed airway geometries, consisting of symmetric, asym- metric, and random obstructions. Fig. 2 shows the geometric ...normal and obstructed airways Airway resistance is a measure of the opposition to the airflow caused by geometric properties, such as airway obstruction...pressure drops. Resistance values were dependent on the degree and geometric distribution of the obstruction sites. In the symmetric obstruction model
2014-01-01
Background Spirometry is commonly accepted as the gold standard for the diagnosis of COPD, but the reality remains that quality assured spirometry is not or cannot be provided universally around the globe. Adding PEF measurement to a screening questionnaire may rule out airflow limitation compatible with COPD rationalizing spirometry testing. Methods We conducted a cross-sectional survey in a sample of individuals 40–80 yrs. old in Dubai, UAE. They were invited to answer a short socio-demographic questionnaire including a report on current, past history of smoking, and had PEF measured, then they conducted spirometry to identify airflow limitation compatible with COPD. Results Overall, 525 (91.0%) participants performed PEF and spirometry (68% male, with a mean age of 59 years, 17% UAE Nationals), 24% reported smoking of different sorts. Overall, 68 participants (12.9%, 95% C.I. 10.3% to 16.1%) had airflow limitation compatible with COPD. PEFR alone identified 141participants with airflow limitation compatible with COPD, with specificity of 80% and sensitivity of 73.5%. Conclusions PEFR could be an easy, cheap, and non-biased tool to assist with the case-finding of COPD before confirmation with spirometry. PMID:24739210
Method of controlling a variable geometry type turbocharger
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirabayashi, Y.
1988-08-23
This patent describes a method of controlling the supercharging pressure of a variable geometry type turbocharger having a bypass, comprising the following steps which are carried out successively: receiving signals from an engine speed sensor and from an engine knocking sensor; receiving a signal from a throttle valve sensor; judging whether or not an engine is being accelerated, and proceeding to step below if the engine is being accelerated and to step below if the engine is not being accelerated, i.e., if the engine is in a constant speed operation; determining a first correction value and proceeding to step below;more » judging whether or not the engine is knocking, and proceeding to step (d) if knocking is occurring and to step (f) below if no knocking is occurring; determining a second correction value and proceeding to step; receiving signals from the engine speed sensor and from an airflow meter which measures the quantity of airflow to be supplied to the engine; calculating an airflow rate per engine revolution; determining a duty valve according to the calculated airflow rate; transmitting the corrected duty value to control means for controlling the geometry of the variable geometry type turbocharger and the opening of bypass of the turbocharger, thereby controlling the supercharging pressure of the turbocharger.« less
Zang, Hongrui; Liu, Yingxi; Han, Demin; Zhang, Luo; Wang, Tong; Sun, Xiuzhen; Li, Lifeng
2012-06-01
The airflow velocity and flux in maxillary sinuses were much lower than those in the nasal cavity, and the temperature in maxillary sinuses was much higher than the temperature in the middle meatus. With the increase of maximum diameter of the ostium, the above indices changed little. The purpose of the paper was to investigate, first, the flow and temperature distribution inside normal maxillary sinus in inspiration, and second, flow and temperature alteration with the increase of maximum ostium diameter. Three-dimensional models with nasal cavities and bilateral maxillary sinuses were constructed for computational fluid dynamics analysis. Virtual surgeries were implemented for the maxillary ostium, the maximum diameters of which were 8, 10, 12, and 15 mm, respectively. The finite volume method was used for numerical simulation. The indices of velocity, pressure, vector, and temperature were processed and compared between models. The airflow velocity in maxillary sinuses (average velocity 0.062 m/s) was much lower than that in the middle meatus (average velocity 3.26 m/s). With the increase of ostium diameter, airflow characteristics distributed in the maxillary sinuses changed little. The normal temperature in the maxillary sinus remained almost constant at 34°C and changed little with the increase of ostium diameter.
Wang, Xue; Wang, Shuhua; Yang, Ya; Wang, Zhong Lin
2015-04-28
We report a hybridized nanogenerator with dimensions of 6.7 cm × 4.5 cm × 2 cm and a weight of 42.3 g that consists of two triboelectric nanogenerators (TENGs) and two electromagnetic generators (EMGs) for scavenging air-flow energy. Under an air-flow speed of about 18 m/s, the hybridized nanogenerator can deliver largest output powers of 3.5 mW for one TENG (in correspondence of power per unit mass/volume: 8.8 mW/g and 14.6 kW/m(3)) at a loading resistance of 3 MΩ and 1.8 mW for one EMG (in correspondence of power per unit mass/volume: 0.3 mW/g and 0.4 kW/m(3)) at a loading resistance of 2 kΩ, respectively. The hybridized nanogenerator can be utilized to charge a capacitor of 3300 μF to sustainably power four temperature sensors for realizing self-powered temperature sensor networks. Moreover, a wireless temperature sensor driven by a hybridized nanogenerator charged Li-ion battery can work well to send the temperature data to a receiver/computer at a distance of 1.5 m. This work takes a significant step toward air-flow energy harvesting and its potential applications in self-powered wireless sensor networks.
Measuring Device for Air Speed in Macroporous Media and Its Application Inside Apple Storage Bins
Geyer, Martin; Praeger, Ulrike; Scaar, Holger; Neuwald, Daniel A.; Gottschalk, Klaus
2018-01-01
In cold storage facilities of fruit and vegetables, airflow is necessary for heat removal. The design of storage facilities influences the air speed in the surrounding of the product. Therefore, knowledge about airflow next to the product is important to plan the layout of cold stores adapted to the requirements of the products. A new sensing device (ASL, Air speed logger) is developed for omnidirectional measurement of air speed between fruit or vegetables inside storage bins or in bulk. It consists of four interconnected plastic spheres with 80 mm diameter each, adapted to the size of apple fruit. In the free space between the spheres, silicon diodes are fixed for the airflow measurement based on a calorimetric principle. Battery and data logger are mounted inside the spheres. The device is calibrated in a wind tunnel in a measuring range of 0–1.3 m/s. Air speed measurements in fruit bulks on laboratory scale and in an industrial fruit store show air speeds in gaps between fruit with high stability at different airflow levels. Several devices can be placed between stored products for determination of the air speed distribution inside bulks or bin stacks in a storage room. PMID:29438339
COMIS -- an international multizone air-flow and contaminant transport model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feustel, H.E.
1998-08-01
A number of interzonal models have been developed to calculate air flows and pollutant transport mechanisms in both single and multizone buildings. A recent development in multizone air-flow modeling, the COMIS model, has a number of capabilities that go beyond previous models, much as COMIS can be used as either a stand-alone air-flow model with input and output features or as an infiltration module for thermal building simulation programs. COMIS was designed during a 12 month workshop at Lawrence Berkeley National Laboratory (LBNL) in 1988-89. In 1990, the Executive Committee of the International Energy Agency`s Energy Conservation in Buildings andmore » Community Systems program created a working group on multizone air-flow modeling, which continued work on COMIS. The group`s objectives were to study physical phenomena causing air flow and pollutant (e.g., moisture) transport in multizone buildings, develop numerical modules to be integrated in the previously designed multizone air flow modeling system, and evaluate the computer code. The working group supported by nine nations, officially finished in late 1997 with the release of IISiBat/COMIS 3.0, which contains the documented simulation program COMIS, the user interface IISiBat, and reports describing the evaluation exercise.« less
No need to change the skin knife in modern arthroplasty surgery.
Ottesen, C; Skovby, A; Troelsen, A; Specht, C; Friis-Møller, A; Husted, H
2014-08-01
Earlier studies have found varying contamination rates using separate skin and deep knives in total hip (THA) and total knee (TKA) arthroplasty surgery. Previous studies were primarily conducted in the setting of concomitant use of laminar airflow and/or plastic adhesive draping. This has lead to conflicting conclusions regarding discarding the skin knife or not. This study evaluates the prevalence of contamination of a separate skin knife using modern antiseptic technique in primary THA and TKA without laminar airflow. Three knives from each primary THA and TKA surgery in non-laminar airflow operating rooms were collected: one used for the skin, one used for deeper tissues and one control knife. A total of 831 knife blades from 277 patients were cultured 12 days. Contamination of the skin knife was found in eight patients (2.8 %), contamination of the "deep" knife in five patients (1.8 %) and contamination of the control knife in five patients (1.8 %). No patient developed an infection with 1-year follow-up. Our findings suggest a very low rate of contamination of the skin knife using modern antiseptic technique without laminar airflow and/or plastic adhesive draping and do not support the use of a separate skin knife in arthroplasty surgery.
Hesselbacher, Sean E.; Ross, Robert; Schabath, Matthew B.; Smith, E. O’Brian; Perusich, Sarah; Barrow, Nadia; Smithwick, Pamela; Mammen, Manoj J.; Coxson, Harvey; Krowchuk, Natasha; Corry, David B.; Kheradmand, Farrah
2011-01-01
Emphysema is largely an under-diagnosed medical condition that can exist in smokers in the absence of airway obstruction. We aimed to determine the sensitivity and specificity of pulmonary function tests (PFTs) in assessing emphysema using quantitative CT scans as the reference standard. We enrolled 224 ever-smokers (current or former) over the age of 40. CT of thorax was used to quantify the low attenuation area (% emphysema), and to measure the standardized airway wall thickness. PFTs were used individually and in combination to predict their ability to discriminate radiographic emphysema. Significant emphysema (>7%) was detected in 122 (54%) subjects. Twenty six (21%) emphysema subjects had no evidence of airflow obstruction (FEV1/FVC ratio <70%), while all subjects with >23% emphysema showed airflow obstruction. The sensitivity and specificity of spirometry for detecting radiographic emphysema were 79% and 75%, respectively. Standardized airway wall thickness was increased in subjects with airflow obstruction, but did not correlate with emphysema severity. In this cohort of lifetime ever-smokers, PFTs alone were inadequate for diagnosing emphysema. Airway wall thickness quantified by CT morphometry was associated with airflow limitation, but not with emphysema indicating that the heterogeneous nature of lung disease in smokers may represent distinct phenotypes. PMID:21655122
Periodontitis is related to lung volumes and airflow limitation: a cross-sectional study.
Holtfreter, Birte; Richter, Stefanie; Kocher, Thomas; Dörr, Marcus; Völzke, Henry; Ittermann, Till; Obst, Anne; Schäper, Christoph; John, Ulrich; Meisel, Peter; Grotevendt, Anne; Felix, Stephan B; Ewert, Ralf; Gläser, Sven
2013-12-01
This study aimed to assess the potential association of periodontal diseases with lung volumes and airflow limitation in a general adult population. Based on a representative population sample of the Study of Health in Pomerania (SHIP), 1463 subjects aged 25-86 years were included. Periodontal status was assessed by clinical attachment loss (CAL), probing depth and number of missing teeth. Lung function was measured using spirometry, body plethysmography and diffusing capacity of the lung for carbon monoxide. Linear regression models using fractional polynomials were used to assess associations between periodontal disease and lung function. Fibrinogen and high-sensitivity C-reactive protein (hs-CRP) were evaluated as potential intermediate factors. After full adjustment for potential confounders mean CAL was significantly associated with variables of mobile dynamic and static lung volumes, airflow limitation and hyperinflation (p<0.05). Including fibrinogen and hs-CRP did not change coefficients of mean CAL; associations remained statistically significant. Mean CAL was not associated with total lung capacity and diffusing capacity of the lung for carbon monoxide. Associations were confirmed for mean probing depth, extent measures of CAL/probing depth and number of missing teeth. Periodontal disease was significantly associated with reduced lung volumes and airflow limitation in this general adult population sample. Systemic inflammation did not provide a mechanism linking both diseases.
Parametric study on the characteristics of a SDBD actuator with a serrated electrode
NASA Astrophysics Data System (ADS)
Gao, Guoqiang; Peng, Kaisheng; Dong, Lei; Wei, Wenfu; Wu, Guangning
2017-06-01
Active flow control based on surface dielectric barrier discharge (SDBD) has become a focus of research in recent years, due to its unique advantages and diverse potential applications. Compared with the conventional SDBD with straight electrodes, the serrated electrode-based SDBD has a great advantage due to its 3D flow topology. It is believed that the boundary layer separation of moving objects can be controlled more effectively with this new type of SDBD. In SDBD with a serrated electrode, the R (tip sharpness) and N (tip number per unit length) have a great influence on the discharge and induced airflow characteristics. In this paper, a parametric study of the characteristics of SDBD with a serrated electrode has been conducted with different ranges of R and N. Aspects of the power consumption, the steady medium temperature distribution, and the maximum induced airflow velocity have been investigated. The results indicate that there is a critical value of R and N where the maximum power consumption and induced airflow velocity are achieved. The uniformity of the steady temperature distribution of the medium surface is found to be more dependent on N. We found that the accelerating effects of the induced airflow can be evaluated with the Schlieren technique, which agree well with the results from the pitot tube.
Mass Median Plume Angle: A novel approach to characterize plume geometry in solution based pMDIs.
Moraga-Espinoza, Daniel; Eshaghian, Eli; Smyth, Hugh D C
2018-05-30
High-speed laser imaging (HSLI) is the preferred technique to characterize the geometry of the plume in pressurized metered dose inhalers (pMDIs). However, current methods do not allow for simulation of inhalation airflow and do not use drug mass quantification to determine plume angles. To address these limitations, a Plume Induction Port Evaluator (PIPE) was designed to characterize the plume geometry based on mass deposition patterns. The method is easily adaptable to current pMDI characterization methodologies, uses similar calculations methods, and can be used under airflow. The effect of airflow and formulation on the plume geometry were evaluated using PIPE and HSLI. Deposition patterns in PIPE were highly reproducible and log-normal distributed. Mass Median Plume Angle (MMPA) was a new characterization parameter to describe the effective angle of the droplets deposited in the induction port. Plume angles determined by mass showed a significant decrease in size as ethanol increases which correlates to the decrease on vapor pressure in the formulation. Additionally, airflow significantly decreased the angle of the plumes when cascade impactor was operated under flow. PIPE is an alternative to laser-based characterization methods to evaluate the plume angle of pMDIs based on reliable drug quantification while simulating patient inhalation. Copyright © 2018. Published by Elsevier B.V.
Celli, B R; Rassulo, J; Make, B J
1986-06-05
Some patients with chronic airflow obstruction experience dyspnea with mild arm exercise but not with more-intense leg exercise. To investigate why these patients have limited endurance during arm exertion, we studied ventilatory responses to exercise with unsupported arms in 12 patients with chronic airflow obstruction (mean [+/- SD] forced expiratory volume in one second, 0.68 +/- 0.28 liters). Unloaded leg cycling was also studied for comparison. In the five patients who had the most severe airflow obstruction, arm exercise was limited by dyspnea after 3.3 +/- 0.7 minutes, and dyssynchronous thoracoabdominal breathing developed. In the other seven patients, arm exercise was limited by the sensation of muscle fatigue after 6.1 +/- 2.0 minutes (P less than 0.05), and dyssynchronous breathing did not occur. None of the 12 patients had dyssynchronous breathing during unloaded leg cycling. Maximal transdiaphragmatic pressure, a measure of diaphragmatic fatigue, declined similarly after arm and leg exercise in both groups. During unsupported arm work, the accessory muscles of inspiration help position the torso and arms. We hypothesize that the extra demand placed on these muscles during arm exertion leads to early fatigue, an increased load on the diaphragm, and dyssynchronous thoracoabdominal inspirations. This sequence may contribute to dyspnea and limited endurance during upper-extremity exercise.
NASA Astrophysics Data System (ADS)
Lucero, Jorge C.; Koenig, Laura L.
2005-03-01
In this study we use a low-dimensional laryngeal model to reproduce temporal variations in oral airflow produced by speakers in the vicinity of an abduction gesture. It attempts to characterize these temporal patterns in terms of biomechanical parameters such as glottal area, vocal fold stiffness, subglottal pressure, and gender differences in laryngeal dimensions. A two-mass model of the vocal folds coupled to a two-tube approximation of the vocal tract is fitted to oral airflow records measured in men and women during the production of /aha/ utterances, using the subglottal pressure, glottal width, and Q factor as control parameters. The results show that the model is capable of reproducing the airflow records with good approximation. A nonlinear damping characteristics is needed, to reproduce the flow variation at glottal abduction. Devoicing is achieved by the combined action of vocal fold abduction, the decrease of subglottal pressure, and the increase of vocal fold tension. In general, the female larynx has a more restricted region of vocal fold oscillation than the male one. This would explain the more frequent devoicing in glottal abduction-adduction gestures for /h/ in running speech by women, compared to men. .
Factors contributing to airborne particle dispersal in the operating room.
Noguchi, Chieko; Koseki, Hironobu; Horiuchi, Hidehiko; Yonekura, Akihiko; Tomita, Masato; Higuchi, Takashi; Sunagawa, Shinya; Osaki, Makoto
2017-07-06
Surgical-site infections due to intraoperative contamination are chiefly ascribable to airborne particles carrying microorganisms. The purpose of this study is to identify the actions that increase the number of airborne particles in the operating room. Two surgeons and two surgical nurses performed three patterns of physical movements to mimic intraoperative actions, such as preparing the instrument table, gowning and donning/doffing gloves, and preparing for total knee arthroplasty. The generation and behavior of airborne particles were filmed using a fine particle visualization system, and the number of airborne particles in 2.83 m 3 of air was counted using a laser particle counter. Each action was repeated five times, and the particle measurements were evaluated through one-way analysis of variance multiple comparison tests followed by Tukey-Kramer and Bonferroni-Dunn multiple comparison tests for post hoc analysis. Statistical significance was defined as a P value ≤ .01. A large number of airborne particles were observed while unfolding the surgical gown, removing gloves, and putting the arms through the sleeves of the gown. Although numerous airborne particles were observed while applying the stockinet and putting on large drapes for preparation of total knee arthroplasty, fewer particles (0.3-2.0 μm in size) were detected at the level of the operating table under laminar airflow compared to actions performed in a non-ventilated preoperative room (P < .01). The results of this study suggest that surgical staff should avoid unnecessary actions that produce a large number of airborne particles near a sterile area and that laminar airflow has the potential to reduce the incidence of bacterial contamination.
Experiments on Analysing Voice Production: Excised (Human, Animal) and In Vivo (Animal) Approaches
Döllinger, Michael; Kobler, James; Berry, David A.; Mehta, Daryush D.; Luegmair, Georg; Bohr, Christopher
2015-01-01
Experiments on human and on animal excised specimens as well as in vivo animal preparations are so far the most realistic approaches to simulate the in vivo process of human phonation. These experiments do not have the disadvantage of limited space within the neck and enable studies of the actual organ necessary for phonation, i.e., the larynx. The studies additionally allow the analysis of flow, vocal fold dynamics, and resulting acoustics in relation to well-defined laryngeal alterations. Purpose of Review This paper provides an overview of the applications and usefulness of excised (human/animal) specimen and in vivo animal experiments in voice research. These experiments have enabled visualization and analysis of dehydration effects, vocal fold scarring, bifurcation and chaotic vibrations, three-dimensional vibrations, aerodynamic effects, and mucosal wave propagation along the medial surface. Quantitative data will be shown to give an overview of measured laryngeal parameter values. As yet, a full understanding of all existing interactions in voice production has not been achieved, and thus, where possible, we try to indicate areas needing further study. Recent Findings A further motivation behind this review is to highlight recent findings and technologies related to the study of vocal fold dynamics and its applications. For example, studies of interactions between vocal tract airflow and generation of acoustics have recently shown that airflow superior to the glottis is governed by not only vocal fold dynamics but also by subglottal and supraglottal structures. In addition, promising new methods to investigate kinematics and dynamics have been reported recently, including dynamic optical coherence tomography, X-ray stroboscopy and three-dimensional reconstruction with laser projection systems. Finally, we touch on the relevance of vocal fold dynamics to clinical laryngology and to clinically-oriented research. PMID:26581597
Regional peak mucosal cooling predicts the perception of nasal patency.
Zhao, Kai; Jiang, Jianbo; Blacker, Kara; Lyman, Brian; Dalton, Pamela; Cowart, Beverly J; Pribitkin, Edmund A
2014-03-01
Nasal obstruction is the principal symptom that drives patients with rhinosinus disease to seek medical treatment. However, patient perception of obstruction often bears little relationship to actual measured physical obstruction of airflow. This lack of an objective clinical tool hinders effective diagnosis and treatment. Previous work has suggested that the perception of nasal patency may involve nasal trigeminal activation by cool inspiratory airflow; we attempt to derive clinically relevant variables following this phenomenon. Prospective healthy cohort. Twenty-two healthy subjects rated unilateral nasal patency in controlled room air using a visual analog scale, followed by rhinomanometry, acoustic rhinometry, and butanol lateralization thresholds (BLTs). Each subject then immediately underwent a computed tomography scan, enabling the construction of a real-time computational fluid dynamics (CFD) nasal airway model, which was used to simulate nasal mucosa heat loss during steady resting breathing. Among all measured and computed variables, only CFD-simulated peak heat loss posterior to the nasal vestibule significantly correlated with patency ratings (r = -0.46, P < .01). Linear discriminant analysis predicted patency categories with 89% success rate, with BLT and rhinomanometric nasal resistance being two additional significant variables. As validation, CFD simulated nasal resistance significantly correlated with rhinomanometrically measured resistance (r = 0.41, P < .01). These results reveal that our noses are sensing patency via a mechanism involving localized peak nasal mucosal cooling. The analysis provides a strong rationale for combining the individualized CFD with other objective and neurologic measures to create a novel clinical tool to diagnose nasal obstruction and to predict and evaluate treatment outcomes. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Influence of shock waves from plasma actuators on transonic and supersonic airflow
NASA Astrophysics Data System (ADS)
Mursenkova, I. V.; Znamenskaya, I. A.; Lutsky, A. E.
2018-03-01
This paper presents experimental and numerical investigations of high-current sliding surface discharges of nanosecond duration and their effect on high-speed flow as plasma actuators in a shock tube. This study deals with the effectiveness of a sliding surface discharge at low and medium air pressure. Results cover the electrical characteristics of the discharge and optical visualization of the discharge and high-speed post-discharge flow. A sliding surface discharge is first studied in quiescent air conditions and then in high-speed flow, being initiated in the boundary layer at a transverse flow velocity of 50-950 m s-1 behind a flat shock wave in air of density 0.04-0.45 kg m-3. The discharge is powered by a pulse voltage of 25-30 kV and the electric current is ~0.5 kA. Shadow imaging and particle image velocimetry (PIV) are used to measure the flow field parameters after the pulse surface discharge. Shadow imaging reveals shock waves originating from the channels of the discharge configurations. PIV is used to measure the velocity field resulting from the discharge in quiescent air and to determine the homogeneity of energy release along the sliding discharge channel. Semicylindrical shock waves from the channels of the sliding discharge have an initial velocity of more than 600 m s-1. The shock-wave configuration floats in the flow along the streamlined surface. Numerical simulation based on the equations of hydrodynamics matched with the experiment showed that 25%-50% of the discharge energy is instantly transformed into heat energy in a high-speed airflow, leading to the formation of shock waves. This energy is comparable to the flow enthalpy and can result in significant modification of the boundary layer and the entire flow.
NASA Technical Reports Server (NTRS)
Lawrence, Charles; Putt, Charles W.
1997-01-01
The Visual Computing Environment (VCE) is a NASA Lewis Research Center project to develop a framework for intercomponent and multidisciplinary computational simulations. Many current engineering analysis codes simulate various aspects of aircraft engine operation. For example, existing computational fluid dynamics (CFD) codes can model the airflow through individual engine components such as the inlet, compressor, combustor, turbine, or nozzle. Currently, these codes are run in isolation, making intercomponent and complete system simulations very difficult to perform. In addition, management and utilization of these engineering codes for coupled component simulations is a complex, laborious task, requiring substantial experience and effort. To facilitate multicomponent aircraft engine analysis, the CFD Research Corporation (CFDRC) is developing the VCE system. This system, which is part of NASA's Numerical Propulsion Simulation System (NPSS) program, can couple various engineering disciplines, such as CFD, structural analysis, and thermal analysis. The objectives of VCE are to (1) develop a visual computing environment for controlling the execution of individual simulation codes that are running in parallel and are distributed on heterogeneous host machines in a networked environment, (2) develop numerical coupling algorithms for interchanging boundary conditions between codes with arbitrary grid matching and different levels of dimensionality, (3) provide a graphical interface for simulation setup and control, and (4) provide tools for online visualization and plotting. VCE was designed to provide a distributed, object-oriented environment. Mechanisms are provided for creating and manipulating objects, such as grids, boundary conditions, and solution data. This environment includes parallel virtual machine (PVM) for distributed processing. Users can interactively select and couple any set of codes that have been modified to run in a parallel distributed fashion on a cluster of heterogeneous workstations. A scripting facility allows users to dictate the sequence of events that make up the particular simulation.
40 CFR 63.7830 - What are my monitoring requirements?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Integrated Iron and Steel... leaks. (viii) Inspect fans for wear, material buildup, and corrosion through quarterly visual...
Cheung, Weng-Fong; Lin, Tzu-Hsuan; Lin, Yu-Cheng
2018-02-02
In recent years, many studies have focused on the application of advanced technology as a way to improve management of construction safety management. A Wireless Sensor Network (WSN), one of the key technologies in Internet of Things (IoT) development, enables objects and devices to sense and communicate environmental conditions; Building Information Modeling (BIM), a revolutionary technology in construction, integrates database and geometry into a digital model which provides a visualized way in all construction lifecycle management. This paper integrates BIM and WSN into a unique system which enables the construction site to visually monitor the safety status via a spatial, colored interface and remove any hazardous gas automatically. Many wireless sensor nodes were placed on an underground construction site and to collect hazardous gas level and environmental condition (temperature and humidity) data, and in any region where an abnormal status is detected, the BIM model will alert the region and an alarm and ventilator on site will start automatically for warning and removing the hazard. The proposed system can greatly enhance the efficiency in construction safety management and provide an important reference information in rescue tasks. Finally, a case study demonstrates the applicability of the proposed system and the practical benefits, limitations, conclusions, and suggestions are summarized for further applications.
Kunimatsu-Sanuki, Shiho; Iwase, Aiko; Araie, Makoto; Aoki, Yuki; Hara, Takeshi; Nakazawa, Toru; Yamaguchi, Takuhiro; Ono, Hiroshi; Sanuki, Tomoyuki; Itoh, Makoto
2015-01-01
Objective To assess the driving fitness of patients with glaucoma by identifying specific areas and degrees of visual field impairment that threaten safe driving. Design Case–control study. Setting, and participants This prospective study included 36 patients with advanced glaucoma, defined as Humphrey field analyzer (HFA; 24-2 SITA standard program) measurements of mean deviation in both eyes of worse than −12 dB, and 36 age-matched and driving exposure time-matched normal subjects. All participants underwent testing in a novel driving simulator (DS) system. Participants were recruited between September 2010 and January 2012. Main outcome measures The number of collisions with simulated hazards and braking response time in 14 DS scenarios was recorded. Monocular HFA 24-2 test results from both eyes were merged to calculate the binocular integrated visual field (IVF). The position of the IVF subfields in which the collision-involved patients had lower sensitivity than the collision-uninvolved patients was compared with the track of the hazard. The cut-off value to predict an elevated risk of collisions was determined, as were its sensitivity and specificity, with the area under the receiver operating characteristic (AUROC) curve. Results Patients with advanced glaucoma were involved in a significantly higher number of collisions in the DS than the age-matched and driving exposure time-matched normal subjects (119 vs 40, respectively, p<0.0001), especially in four specific DS scenarios. In these four scenarios, IVF sensitivity was significantly lower in the collision-involved patients than in the collision-uninvolved patients in subfields on or near the track of the simulated hazard (p<0.05). The subfields with the largest AUROC curve had values ranging from 0.72 to 0.91 and were located in the paracentral visual field just below the horizontal. Conclusions Our novel DS system effectively assessed visual impairment, showing that simulators may have future potential in educating patients. PMID:25724982
Exploring eye movements in patients with glaucoma when viewing a driving scene.
Crabb, David P; Smith, Nicholas D; Rauscher, Franziska G; Chisholm, Catharine M; Barbur, John L; Edgar, David F; Garway-Heath, David F
2010-03-16
Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of 'point-of-regard' of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive.
Exploring Eye Movements in Patients with Glaucoma When Viewing a Driving Scene
Crabb, David P.; Smith, Nicholas D.; Rauscher, Franziska G.; Chisholm, Catharine M.; Barbur, John L.; Edgar, David F.; Garway-Heath, David F.
2010-01-01
Background Glaucoma is a progressive eye disease and a leading cause of visual disability. Automated assessment of the visual field determines the different stages in the disease process: it would be desirable to link these measurements taken in the clinic with patient's actual function, or establish if patients compensate for their restricted field of view when performing everyday tasks. Hence, this study investigated eye movements in glaucomatous patients when viewing driving scenes in a hazard perception test (HPT). Methodology/Principal Findings The HPT is a component of the UK driving licence test consisting of a series of short film clips of various traffic scenes viewed from the driver's perspective each containing hazardous situations that require the camera car to change direction or slow down. Data from nine glaucomatous patients with binocular visual field defects and ten age-matched control subjects were considered (all experienced drivers). Each subject viewed 26 different films with eye movements simultaneously monitored by an eye tracker. Computer software was purpose written to pre-process the data, co-register it to the film clips and to quantify eye movements and point-of-regard (using a dynamic bivariate contour ellipse analysis). On average, and across all HPT films, patients exhibited different eye movement characteristics to controls making, for example, significantly more saccades (P<0.001; 95% confidence interval for mean increase: 9.2 to 22.4%). Whilst the average region of ‘point-of-regard’ of the patients did not differ significantly from the controls, there were revealing cases where patients failed to see a hazard in relation to their binocular visual field defect. Conclusions/Significance Characteristics of eye movement patterns in patients with bilateral glaucoma can differ significantly from age-matched controls when viewing a traffic scene. Further studies of eye movements made by glaucomatous patients could provide useful information about the definition of the visual field component required for fitness to drive. PMID:20300522
Communist China. Section 23. Weather and Climate. Part 3 - North China
1964-06-01
Introduction 1 2. Climatic controls 2 a. General circulation and air masses 2 b. Migratory pressure systems and fronts 3 (1) Extratropical ...Sea-level pressure and surface airflow, January (map) 2 Fig. 2 Sea-level pressure and surface airflow, July (mop) 2 Fig. 3 Tracks of extratropical ...become weaker and less frequent as those of the invading monsoon become more prevalent. b. MIGRATORY PRESSURE SYSTEMS AND FRONTS (1) Extratropical
Hiep Van Nguyen; Yie-Leng Chen; Francis Fujioka
2010-01-01
The high-resolution (1.5 km) nonhydrostatic fifth-generation Pennsylvania StateUniversityâNational Center for Atmospheric Research (PSUâNCAR) Mesoscale Model (MM5) and an advanced land surface model (LSM) are used to study the island-induced airflow and weather for the island of Oahu, Hawaii, under summer trade wind conditions. Despite Oahuâs relatively small...
Aircraft Survivability: Unmanned Aircraft Systems Survivability. Fall 2008
2008-01-01
until June 2005. Upon deactivation, LtCol Matthews became the “Marine JCAT of One” and was assigned to the 4th Marine Aircraft Wing as a drilling ...strain gauges along with high- speed video. Seven tests were accomplished (Figure 5): four with no airflow, and three with 200 knots of airflow across...collection for manned and unmanned systems to support vulnerability testing and analysis. As Figure 7 illustrates, the system uses advanced metrology
Assessment of zero-equation SGS models for simulating indoor environment
NASA Astrophysics Data System (ADS)
Taghinia, Javad; Rahman, Md Mizanur; Tse, Tim K. T.
2016-12-01
The understanding of air-flow in enclosed spaces plays a key role to designing ventilation systems and indoor environment. The computational fluid dynamics aspects dictate that the large eddy simulation (LES) offers a subtle means to analyze complex flows with recirculation and streamline curvature effects, providing more robust and accurate details than those of Reynolds-averaged Navier-Stokes simulations. This work assesses the performance of two zero-equation sub-grid scale models: the Rahman-Agarwal-Siikonen-Taghinia (RAST) model with a single grid-filter and the dynamic Smagorinsky model with grid-filter and test-filter scales. This in turn allows a cross-comparison of the effect of two different LES methods in simulating indoor air-flows with forced and mixed (natural + forced) convection. A better performance against experiments is indicated with the RAST model in wall-bounded non-equilibrium indoor air-flows; this is due to its sensitivity toward both the shear and vorticity parameters.
Mechanical Design of a Performance Test Rig for the Turbine Air-Flow Task (TAFT)
NASA Technical Reports Server (NTRS)
Forbes, John C.; Xenofos, George D.; Farrow, John L.; Tyler, Tom; Williams, Robert; Sargent, Scott; Moharos, Jozsef
2004-01-01
To support development of the Boeing-Rocketdyne RS84 rocket engine, a full-flow, reaction turbine geometry was integrated into the NASA-MSFC turbine air-flow test facility. A mechanical design was generated which minimized the amount of new hardware while incorporating all test and instrumentation requirements. This paper provides details of the mechanical design for this Turbine Air-Flow Task (TAFT) test rig. The mechanical design process utilized for this task included the following basic stages: Conceptual Design. Preliminary Design. Detailed Design. Baseline of Design (including Configuration Control and Drawing Revision). Fabrication. Assembly. During the design process, many lessons were learned that should benefit future test rig design projects. Of primary importance are well-defined requirements early in the design process, a thorough detailed design package, and effective communication with both the customer and the fabrication contractors.
Numerical Investigation of the Turbulent Wind Flow Through Elevated Windbreak
NASA Astrophysics Data System (ADS)
Agarwal, Ashish; Irtaza, Hassan
2018-06-01
Analysis of airflow through elevated windbreaks is presented in this paper. Permeable nets and impermeable film increases considerable wind forces on the windbreaks which is susceptible to damage during high wind. A comprehensive numerical investigation has been carried out to analyze the effects of wind on standalone elevated windbreak clad with various permeable nets and an impermeable film. The variation of airflow behavior around and through permeable nets and airflow behavior around impermeable film were also been investigated. Computational fluid dynamics techniques using Reynolds Averaged Navier-Stokes equations has been used to predict the wind force coefficient and thus wind forces on panels supporting permeable nets and impermeable film for turbulent wind flow. Elevated windbreak panels were analyzed for seven different permeable nets having various solidity ratio, specific permeability and aerodynamic resistant coefficients. The permeable nets were modelled as porous jump media obeying Forchheimer's law and an impermeable film modelled as rigid wall.
A budget of energy transfer in a sustained vocal folds vibration in glottis
NASA Astrophysics Data System (ADS)
Zhang, Lucy; Yang, Jubiao; Krane, Michael
2016-11-01
A set of force and energy balance equations using the control volume approach is derived based on the first principles of physics for a sustained vocal folds vibration in glottis. The control volume analysis is done for compressible airflow in a moving and deforming control volume in the vicinity of the vocal folds. The interaction between laryngeal airflow and vocal folds are successfully simulated using the modified Immersed Finite Element Method (mIFEM), a fully coupled approach to simulate fluid-structure interactions. Detailed mathematical terms are separated out for deeper physical understanding and utilization of mechanical energy is quantified with the derived equation. The results show that majority of energy input is consumed for driving laryngeal airflow, while a smaller portion is for compensating viscous losses in and sustaining the vibration of the vocal folds. We acknowledge the funding support of NIH 2R01DC005642-10A1.
Methane emissions and airflow patterns along longwall faces and through bleeder ventilation systems
Schatzel, Steven J.; Dougherty, Heather N.
2015-01-01
The National Institute for Occupational Safety and Health (NIOSH) conducted an investigation of longwall face and bleeder ventilation systems using tracer gas experiments and computer network ventilation. The condition of gateroad entries, along with the caved material’s permeability and porosity changes as the longwall face advances, determine the resistance of the airflow pathways within the longwall’s worked-out area of the bleeder system. A series of field evaluations were conducted on a four-panel longwall district. Tracer gas was released at the mouth of the longwall section or on the longwall face and sampled at various locations in the gateroads inby the shield line. Measurements of arrival times and concentrations defined airflow/gas movements for the active/completed panels and the bleeder system, providing real field data to delineate these pathways. Results showed a sustained ability of the bleeder system to ventilate the longwall tailgate corner as the panels retreated. PMID:26925166
Influence of airflow rate and substrate nature on heterogeneous struvite precipitation.
Saidou, H; Ben Moussa, S; Ben Amor, M
2009-01-01
In wastewater treatment plants a hard scale consisting of struvite crystals can be formed, in pipes and recirculation pumps, during anaerobic digestion of wastewater. This study was conducted to evaluate the effect of airflow rate and substrate nature on nucleation type, induction period and supersaturation coefficient during struvite precipitation. A crystallization reactor similar to that designed for calcium carbonate precipitation was used. The pH of synthetic wastewater solution was increased by air bubbling. Experimental results indicated that the airflow increased heterogeneous precipitation of struvite. The susceptibility to scale formation was more important on polyamide and polyvinyl chloride than on stainless steel. In all cases, X-ray diffraction and infrared spectroscopy showed that the precipitated solid phase was solely struvite. No difference in crystal morphology was observed. However, at similar experimental conditions, the particle size of struvite was higher for stainless-steel material than that for plastic materials.
Numerical Investigation of the Turbulent Wind Flow Through Elevated Windbreak
NASA Astrophysics Data System (ADS)
Agarwal, Ashish; Irtaza, Hassan
2018-04-01
Analysis of airflow through elevated windbreaks is presented in this paper. Permeable nets and impermeable film increases considerable wind forces on the windbreaks which is susceptible to damage during high wind. A comprehensive numerical investigation has been carried out to analyze the effects of wind on standalone elevated windbreak clad with various permeable nets and an impermeable film. The variation of airflow behavior around and through permeable nets and airflow behavior around impermeable film were also been investigated. Computational fluid dynamics techniques using Reynolds Averaged Navier-Stokes equations has been used to predict the wind force coefficient and thus wind forces on panels supporting permeable nets and impermeable film for turbulent wind flow. Elevated windbreak panels were analyzed for seven different permeable nets having various solidity ratio, specific permeability and aerodynamic resistant coefficients. The permeable nets were modelled as porous jump media obeying Forchheimer's law and an impermeable film modelled as rigid wall.
Anstey, Kaarin J; Horswill, Mark S; Wood, Joanne M; Hatherly, Christopher
2012-03-01
The current study evaluated part of the Multifactorial Model of Driving Safety to elucidate the relative importance of cognitive function and a limited range of standard measures of visual function in relation to the Capacity to Drive Safely. Capacity to Drive Safely was operationalized using three validated screening measures for older drivers. These included an adaptation of the well validated Useful Field of View (UFOV) and two newer measures, namely a Hazard Perception Test (HPT), and a Hazard Change Detection Task (HCDT). Community dwelling drivers (n=297) aged 65-96 were assessed using a battery of measures of cognitive and visual function. Factor analysis of these predictor variables yielded factors including Executive/Speed, Vision (measured by visual acuity and contrast sensitivity), Spatial, Visual Closure, and Working Memory. Cognitive and Vision factors explained 83-95% of age-related variance in the Capacity to Drive Safely. Spatial and Working Memory were associated with UFOV, HPT and HCDT, Executive/Speed was associated with UFOV and HCDT and Vision was associated with HPT. The Capacity to Drive Safely declines with chronological age, and this decline is associated with age-related declines in several higher order cognitive abilities involving manipulation and storage of visuospatial information under speeded conditions. There are also age-independent effects of cognitive function and vision that determine driving safety. Copyright © 2011 Elsevier Ltd. All rights reserved.
Jabs, Douglas A.; Drye, Lea; Van Natta, Mark L.; Thorne, Jennifer E.; Holland, Gary N.
2014-01-01
Objectives Patients with the acquired immunodeficiency syndrome (AIDS) have an abnormality of retina/optic nerve function, manifested as decreased contrast sensitivity (in the absence of ocular opportunistic infections or media opacity), abnormalities on automated perimetry, and loss of retinal nerve fiber layer, even among those with good visual acuity, termed the HIV-neuroretinal disorder. The objectives of this study were to determine the prevalence, incidence, risk factors for, and outcomes of HIV-neuroretinal disorder. Design Prospective cohort study Participants 1822 patients with AIDS without ocular infections or media opacities. Methods Patients with HIV-neuroretinal disorder were identified by a contrast sensitivity < 1.50 log units in either eye in the absence of ocular opportunistic infections or media opacity. Main outcome measures Incidence of HIV-neuroretinal disorder, mortality, visual impairment (visual acuity 20/50 or worse), and blindness (20/200 or worse) on logarithmic visual acuity charts. Results Sixteen percent of participants had HIV-neuroretinal disorder at enrollment. The estimated cumulative incidence by 20 years after AIDS diagnosis was 51% (95% confidence interval [CI] 46%–55%). HIV-neuroretinal disorder was more common in women and African American persons. Risk factors for it included hepatitis C infection, low CD4+ T cells, and detectable HIV RNA in the blood. Patients with HIV neuroretinal disorder had a 70% excess mortality vs. those without it, even after adjusting for CD4+ T cells and HIV load (hazard ratio=1.7, 95% CI= 1.3–2.1, P<0.0001). Patients with HIV-neuroretinal disorder had increased risks of bilateral visual impairment (hazard ratio=6.5, 95% CI=2.6–10.6, P<0.0001) and blindness (hazard ratio=5.9, 95% CI=2.8–13.7, P=0.01) vs. those without HIV neuroretinal disorder. Conclusions HIV-neuroretinal disorder is a common finding among patients with AIDS, and it is associated with an increased mortality and an increased risk of visual impairment. Successful antiretroviral therapy decreases but does not eliminate the risk of HIV-neuroretinal disorder. PMID:25600199
Hazard recognition in mining: A psychological perspective. Information circular/1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perdue, C.W.; Kowalski, K.M.; Barrett, E.A.
1995-07-01
This U.S. Bureau of Mines report considers, from a psychological perspective, the perceptual process by which miners recognize and respond to mining hazards. It proposes that if the hazard recognition skills of miners can be improved, mining accidents may be reduced to a significant degree. Prior studies of hazard perception in mining are considered, as are relevant studies from investigations of military target identification, pilot and gunnery officer training, transportation safety, automobile operator behavior, as well as research into sensory functioning and visual information processing. A general model of hazard perception is introduced, and selected concepts from the psychology ofmore » perception that are applicable to the detection of mining hazards are reviewed. Hazard recognition is discussed as a function of the perceptual cues available to the miner as well as the cognitive resources and strategies employed by the miner. The development of expertise in resonding to hazards is related to individual differences in the experience, aptitude, and personality of the worker. Potential applications to miner safety and training are presented.« less
NASA Astrophysics Data System (ADS)
Russell, Robert William
I studied the ecology of aerial insects and birds (the "aerofauna") during the Convection and Precipitation/Electrification (CaPE) Experiment in Florida during the summer of 1991. Visual observations were coordinated with simultaneous measurements of atmospheric motions, permitting novel explorations of: (1) patterns and processes in the distribution of "aerial plankton" (i.e., small, weakly flying insects that drift with boundary-layer winds); (2) the feeding ecology of "aerial planktivores" (i.e., predators that feed on aerial plankton); and (3) the flight tactics of soaring birds. Sensitive Doppler radars regularly detected fine lines of enhanced reflectivity in boundary-layer convergence zones. These "fine lines" were attributable to dense concentrations of aerial plankton entrained by the convergent airflow. Insect densities were inferred to be about an order of magnitude higher inside convergence zones then elsewhere. Anecdotal observations suggested that large quantities of aerial plankton entrained in convergence zones were sometimes "scrubbed" from the boundary layer by precipitation. Radar images clearly depicted the rapid aeolian transport of aerial plankton across the landscape, but also showed that densities of aerial plankton became concentrated along coastlines when winds blew toward the sea. In contrast, airspace over the adjacent ocean remained largely free of radar echoes under all wind conditions. The coastal concentrations, together with the absence of overwater echoes, indicate that the organisms comprising the aerial plankton respond behaviorally to coastlines to avoid being blown out to sea. Several species of aerial insectivorous predators commonly exploited boundary-layer fine lines as food resources. Chimney swifts (Chaetura pelagica), barn swallows (Hirundo rustica), and wandering gliders (Pantala flavescens) showed significant responses to fine lines. Details of these responses differed, but this variation clearly reflected species-specific behavioral constraints and life-history characteristics. Vertical airflows were predictably enhanced in convergence lines, and soaring birds, which require ascending air to employ their preferred mode of flight, appeared to use these lines as aerial corridors for cross-country travel. Theoretical analyses showed that convergence lines can be profitably exploited under a wide variety of circumstances. The results presented here indicate that sensitive Doppler radars capable of detecting clear-air motions offer tremendous potential as research platforms for future studies of the "aerofauna.".
The relationship between the Nasality Severity Index 2.0 and perceptual judgments of hypernasality.
Bettens, Kim; De Bodt, Marc; Maryn, Youri; Luyten, Anke; Wuyts, Floris L; Van Lierde, Kristiane M
2016-01-01
The Nasality Severity Index 2.0 (NSI 2.0) forms a new, multiparametric approach in the identification of hypernasality. The present study aimed to investigate the correlation between the NSI 2.0 scores and the perceptual assessment of hypernasality. Speech samples of 35 patients, representing a range of nasality from normal to severely hypernasal, were rated by four expert speech-language pathologists using visual analogue scaling (VAS) judging the degree of hypernasality, audible nasal airflow (ANA) and speech intelligibility. Inter- and intra-listener reliability was verified using intraclass correlation coefficients. Correlations between NSI 2.0 scores and its parameters (i.e. nasalance score of an oral text and vowel /u/, voice low tone to high tone ratio of the vowel /i/) and the degree of hypernasality were determined using Pearson correlation coefficients. Multiple linear regression analysis was used to investigate the possible influence of ANA and speech intelligibility on the NSI 2.0 scores. Overall good to excellent inter- and intra-listener reliability was found for the perceptual ratings. A moderate, but significant negative correlation between NSI 2.0 scores and perceived hypernasality (r=-0.64) was found, in which a more negative NSI 2.0 score indicates the presence of more severe hypernasality. No significant influence of ANA or intelligibility on the NSI 2.0 was observed based on the regression analysis. Because the NSI 2.0 correlates significantly with perceived hypernasality, it provides an easy-to-interpret severity score of hypernasality which will facilitate the evaluation of therapy outcomes, communication to the patient and other clinicians, and decisions for treatment planning, based on a multiparametric approach. However, research is still necessary to further explore the instrumental correlates of perceived hypernasality. The reader will be able to (1) describe and discuss current issues and influencing variables regarding perceptual ratings of hypernasality; (2) describe and discuss the relationship between the Nasality Severity Index 2.0, a new multiparametric approach to hypernasality, and perceptual judgments of hypernasality based on visual analogue scale ratings; (3) compare these results with the correlations based on a single parameter approach and (4) describe and discuss the possible influence of audible nasal airflow and speech intelligibility on the NSI 2.0 scores. Copyright © 2016 Elsevier Inc. All rights reserved.
Two-component wind fields over ocean waves using atmospheric lidar and motion estimation algorithms
NASA Astrophysics Data System (ADS)
Mayor, S. D.
2016-02-01
Numerical models, such as large eddy simulations, are capable of providing stunning visualizations of the air-sea interface. One reason for this is the inherent spatial nature of such models. As compute power grows, models are able to provide higher resolution visualizations over larger domains revealing intricate details of the interactions of ocean waves and the airflow over them. Spatial observations on the other hand, which are necessary to validate the simulations, appear to lag behind models. The rough ocean environment of the real world is an additional challenge. One method of providing spatial observations of fluid flow is that of particle image velocimetry (PIV). PIV has been successfully applied to many problems in engineering and the geosciences. This presentation will show recent research results that demonstate that a PIV-style approach using pulsed-fiber atmospheric elastic backscatter lidar hardware and wavelet-based optical flow motion estimation software can reveal two-component wind fields over rough ocean surfaces. Namely, a recently-developed compact lidar was deployed for 10 days in March of 2015 in the Eureka, California area. It scanned over the ocean. Imagery reveal that breaking ocean waves provide copius amounts of particulate matter for the lidar to detect and for the motion estimation algorithms to retrieve wind vectors from. The image below shows two examples of results from the experiment. The left panel shows the elastic backscatter intensity (copper shades) under a field of vectors that was retrieved by the wavelet-based optical flow algorithm from two scans that took about 15 s each to acquire. The vectors, that reveal offshore flow toward the NW, were decimated for clarity. The bright aerosol features along the right edge of the sector scan were caused by ocean waves breaking on the beach. The right panel is the result of scanning over the ocean on a day when wave amplitudes ranged from 8-12 feet and whitecaps offshore beyond the surf zone appeared to be rare and fleeting. Nonetheless, faint coherent aerosol structures are observable in the backscatter field as long, streaky, wind-parallel filaments and a wind field was retrieved. During the 10-day deployment, the seas were not as rough as expected. A current goal is to find collaborators and return to map airflow in rougher conditions.
Tanaka, Rie; Sanada, Shigeru; Okazaki, Nobuo; Kobayashi, Takeshi; Fujimura, Masaki; Yasui, Masahide; Matsui, Takeshi; Nakayama, Kazuya; Nanbu, Yuko; Matsui, Osamu
2006-10-01
Dynamic flat panel detectors (FPD) permit acquisition of distortion-free radiographs with a large field of view and high image quality. The present study was performed to evaluate pulmonary function using breathing chest radiography with a dynamic FPD. We report primary results of a clinical study and computer algorithm for quantifying and visualizing relative local pulmonary airflow. Dynamic chest radiographs of 18 subjects (1 emphysema, 2 asthma, 4 interstitial pneumonia, 1 pulmonary nodule, and 10 normal controls) were obtained during respiration using an FPD system. We measured respiratory changes in distance from the lung apex to the diaphragm (DLD) and pixel values in each lung area. Subsequently, the interframe differences (D-frame) and difference values between maximum inspiratory and expiratory phases (D-max) were calculated. D-max in each lung represents relative vital capacity (VC) and regional D-frames represent pulmonary airflow in each local area. D-frames were superimposed on dynamic chest radiographs in the form of color display (fusion images). The results obtained using our methods were compared with findings on computed tomography (CT) images and pulmonary functional test (PFT), which were examined before inclusion in the study. In normal subjects, the D-frames were distributed symmetrically in both lungs throughout all respiratory phases. However, subjects with pulmonary diseases showed D-frame distribution patterns that differed from the normal pattern. In subjects with air trapping, there were some areas with D-frames near zero indicated as colorless areas on fusion images. These areas also corresponded to the areas showing air trapping on computed tomography images. In asthma, obstructive abnormality was indicated by areas continuously showing D-frame near zero in the upper lung. Patients with interstitial pneumonia commonly showed fusion images with an uneven color distribution accompanied by increased D-frames in the area identified as normal on computed tomography images. Furthermore, measurement of DLD was very effective for evaluating diaphragmatic kinetics. This is a rapid and simple method for evaluation of respiratory kinetics for pulmonary diseases, which can reveal abnormalities in diaphragmatic kinetics and regional lung ventilation. Furthermore, quantification and visualization of respiratory kinetics is useful as an aid in interpreting dynamic chest radiographs.
Information Extraction for System-Software Safety Analysis: Calendar Year 2008 Year-End Report
NASA Technical Reports Server (NTRS)
Malin, Jane T.
2009-01-01
This annual report describes work to integrate a set of tools to support early model-based analysis of failures and hazards due to system-software interactions. The tools perform and assist analysts in the following tasks: 1) extract model parts from text for architecture and safety/hazard models; 2) combine the parts with library information to develop the models for visualization and analysis; 3) perform graph analysis and simulation to identify and evaluate possible paths from hazard sources to vulnerable entities and functions, in nominal and anomalous system-software configurations and scenarios; and 4) identify resulting candidate scenarios for software integration testing. There has been significant technical progress in model extraction from Orion program text sources, architecture model derivation (components and connections) and documentation of extraction sources. Models have been derived from Internal Interface Requirements Documents (IIRDs) and FMEA documents. Linguistic text processing is used to extract model parts and relationships, and the Aerospace Ontology also aids automated model development from the extracted information. Visualizations of these models assist analysts in requirements overview and in checking consistency and completeness.
Examination of a newly developed mobile dry scrubber (DS) for coal mine dust control applications
Organiscak, J.; Noll, J.; Yantek, D.; Kendall, B.
2017-01-01
The Office of Mine Safety and Health Research of the U.S. National Institute for Occupational Safety and Health (NIOSH OMSHR) conducted laboratory testing of a self-tramming, remotely controlled mobile Dry Scrubber (DS) that J.H. Fletcher and Co. developed under a contract with NIOSH OMSHR to reduce the exposure of miners to airborne dust. The scrubber was found to average greater than 95 percent dust removal efficiency with disposable filters, and 88 and 90 percent, respectively, with optional washable filters in their prewash and post-wash test conditions. Although the washable filters can be reused, washing them generated personal and downstream respirable dust concentrations of 1.2 and 8.3 mg/m3, respectively, for a 10-min washing period. The scrubber’s velocity-pressure-regulated variable-frequency-drive fan maintained relatively consistent airflow near the targeted 1.42 and 4.25 m3/s (3,000 and 9,000 ft3/min) airflow rates during most of the laboratory dust testing until reaching its maximum 60-Hz fan motor frequency or horsepower rating at 2,610 Pa (10.5 in. w.g.) of filter differential pressure and 3.97 m3/s (8,420 ft3/min) of scrubber airflow quantity. Laboratory sound level measurements of the scrubber showed that the outlet side of the scrubber was noisier, and the loaded filters increased sound levels compared with clean filters at the same airflow quantities. With loaded filters, the scrubber reached a 90 dB(A) sound level at 2.83 m3/s (6,000 ft3/min) of scrubber airflow, indicating that miners should not be overexposed in relation to MSHA’s permissible exposure level — under Title 30 Code of Federal Regulations Part 62.101— of 90 dB(A) at or below this airflow quantity. The scrubber’s washable filters were not used during field-testing because of their lower respirable dust removal efficiency and the airborne dust generated by filter washing. Field-testing the scrubber with disposable filters at two underground coal mine sections showed that it could clean a portion of the section return air and provide dust reduction of about 50 percent at the face area downstream of the continuous-miner operation. PMID:28596699
Agent-based Modeling with MATSim for Hazards Evacuation Planning
NASA Astrophysics Data System (ADS)
Jones, J. M.; Ng, P.; Henry, K.; Peters, J.; Wood, N. J.
2015-12-01
Hazard evacuation planning requires robust modeling tools and techniques, such as least cost distance or agent-based modeling, to gain an understanding of a community's potential to reach safety before event (e.g. tsunami) arrival. Least cost distance modeling provides a static view of the evacuation landscape with an estimate of travel times to safety from each location in the hazard space. With this information, practitioners can assess a community's overall ability for timely evacuation. More information may be needed if evacuee congestion creates bottlenecks in the flow patterns. Dynamic movement patterns are best explored with agent-based models that simulate movement of and interaction between individual agents as evacuees through the hazard space, reacting to potential congestion areas along the evacuation route. The multi-agent transport simulation model MATSim is an agent-based modeling framework that can be applied to hazard evacuation planning. Developed jointly by universities in Switzerland and Germany, MATSim is open-source software written in Java and freely available for modification or enhancement. We successfully used MATSim to illustrate tsunami evacuation challenges in two island communities in California, USA, that are impacted by limited escape routes. However, working with MATSim's data preparation, simulation, and visualization modules in an integrated development environment requires a significant investment of time to develop the software expertise to link the modules and run a simulation. To facilitate our evacuation research, we packaged the MATSim modules into a single application tailored to the needs of the hazards community. By exposing the modeling parameters of interest to researchers in an intuitive user interface and hiding the software complexities, we bring agent-based modeling closer to practitioners and provide access to the powerful visual and analytic information that this modeling can provide.
Schofield, Andrew J; Curzon-Jones, Benjamin; Hollands, Mark A
2017-02-01
Falls on stairs are a major hazard for older adults. Visual decline in normal ageing can affect step-climbing ability, altering gait and reducing toe clearance. Here we show that a loss of fine-grained visual information associated with age can affect the perception of surface undulations in patterned surfaces. We go on to show that such cues affect the limb trajectories of young adults, but due to their lack of sensitivity, not that of older adults. Interestingly neither the perceived height of a step nor conscious awareness is altered by our visual manipulation, but stepping behaviour is, suggesting that the influence of shape perception on stepping behaviour is via the unconscious, action-centred, dorsal visual pathway.
Rocky Mountain Research Station USDA Forest Service
2005-01-01
The Guide to Fuel Treatments analyzes a range of potential silvicultural thinnings and surface fuel treatments for 25 representative dry-forest stands in the Western United States. The guide provides quantitative guidelines and visualization for treatment based on scientific principles identified for reducing potential crown fires. This fact sheet identifies the...
Payload bay atmospheric vent airflow testing at the Vibration and Acoustic Test Facility
NASA Technical Reports Server (NTRS)
Johnston, James D., Jr.
1988-01-01
Several concerns related to venting the Space Shuttle Orbiter payload bay during launch led to laboratory experiments with a flight-type vent box installed in the wall of a subsonic wind tunnel. This report describes the test setups and procedures used to acquire data for characterization of airflow through the vent box and acoustic tones radiated from the vent-box cavity. A flexible boundary-layer spoiler which reduced the vent-tone amplitude is described.
Wei, Zehong; Xu, Zhixiang; Li, Bo; Xu, Fuqiang
2013-01-01
The sense of smell is largely dependent on the airflow and odorant transport in the nasal cavity, which in turn depends on the anatomical structure of the nose. In order to evaluate the effect of airway dimension on rat nasal airflow patterns and odorant deposition patterns, we constructed two 3-dimensional, anatomically accurate models of the left nasal cavity of a Sprague-Dawley rat: one was based on high-resolution MRI images with relatively narrow airways and the other was based on artificially-widening airways of the MRI images by referencing the section images with relatively wide airways. Airflow and odorant transport, in the two models, were determined using the method of computational fluid dynamics with finite volume method. The results demonstrated that an increase of 34 µm in nasal airway dimension significantly decreased the average velocity in the whole nasal cavity by about 10% and in the olfactory region by about 12% and increased the volumetric flow into the olfactory region by about 3%. Odorant deposition was affected to a larger extent, especially in the olfactory region, where the maximum odorant deposition difference reached one order of magnitude. The results suggest that a more accurate nasal cavity model is necessary in order to more precisely study the olfactory function of the nose when using the rat. PMID:24204875
NASA Technical Reports Server (NTRS)
Won, Mark J.
1990-01-01
Wind tunnel tests of propulsion-integrated aircraft models have identified inlet flow distortion as a major source of compressor airflow measurement error in turbine-powered propulsion simulators. Consequently, two Compact Multimission Aircraft Propulsion Simulator (CMAPS) units were statically tested at sea level ambient conditions to establish simulator operating performance characteristics and to calibrate the compressor airflow against an accurate bellmouth flowmeter in the presence of inlet flow distortions. The distortions were generated using various-shaped wire mesh screens placed upstream of the compressor. CMAPS operating maps and performance envelopes were obtained for inlet total pressure distortions (ratio of the difference between the maximum and minimum total pressures to the average total pressure) up to 35 percent, and were compared to baseline simulator operating characteristics for a uniform inlet. Deviations from CMAPS baseline performance were attributed to the coupled variation of both compressor inlet-flow distortion and Reynolds number index throughout the simulator operating envelope for each screen configuration. Four independent methods were used to determine CMAPS compressor airflow; direct compressor inlet and discharge measurements, an entering/exiting flow-balance relationships, and a correlation between the mixer pressure and the corrected compressor airflow. Of the four methods, the last yielded the least scatter in the compressor flow coefficient, approximately + or - 3 percent over the range of flow distortions.
Liao, C M
1997-01-01
A quantification analysis for evaluation of gaseous pollutant volatilization as a result of mass transfer from stored swine manure is presented from the viewpoint of residence time distribution. The method is based on evaluating the moments of concentration vs. time curves of both air and gaseous pollutants. The concept of moments of concentration histories is applicable to characterize the dispersal of the supplied air or gaseous pollutant in a ventilated system. The mean age or residence time of airflow can be calculated from an inverse system state matrix [B]-1 of a linear dynamic equation describing the dynamics of gaseous pollutant in a ventilated airspace. The sum elements in an arbitrary row i in matrix [B]-1 is equal to the mean age of airflow in airspace i. The mean age of gaseous pollutant in airspace i can be obtained from the area under the concentration profile divided by the equilibrium concentration reading in that space caused by gaseous pollutant sources. Matrix [B]-1 can also be represented in terms of the inverse local airflow rate matrix ([W]-1), transition probability matrix ([P]), and air volume matrix ([V]) as, [B]-1 = [W]-1[P][V]. Finally the mean age of airflow in a ventilated airspace can be interpreted by the physical characteristics of matrices [W] and [P]. The practical use of the concepts is also applied in a typical pig unit.
Wang, Hao; Cheng, Weimin; Sun, Biao; Yu, Haiming; Jin, Hu
2018-03-01
To understand the impacts of the axial-to-radial airflow quantity ratio (denoted as R) and the suction distance (denoted as D s ) on air curtain dust control in a fully mechanized coal face, the 3 down 610 coal face in Jiangzhuang coal mine was numerically simulated in this study. A mathematic model was established to describe the airflow migration and dust diffusion in a coal face, and a scaled physical model was constructed. The comparison between simulation results and field measurements validated the model and the parameter settings. Furthermore, the airflow migration and dust diffusion at various R and D s are analyzed using Ansys CFD. The results show that a reduction of R and D s is conducive to the formation of an effective axial dust control air curtain; the dust diffusion distance decreases with the decrease of both R and D s . By analyzing the simulation results, the optimal parameter for air curtain dust control in the 3 down 610 coal face and those faces with similar production conditions is determined as R = 1/9 and D s = 2 m. Under the optimal parameter condition, the high-concentration dust can be confined in front of the mining driver within a space 5.8 m away from the coal face.