Science.gov

Sample records for airways pressure cpap

  1. When continuous positive airway pressure (CPAP) fails

    PubMed Central

    Virk, Jagdeep S.

    2016-01-01

    Obstructive sleep apnoea (OSA) is increasingly prevalent, particularly in the context of the obesity epidemic, and is associated with a significant social, health and economic impact. The gold standard of treatment for moderate to severe OSA is continuous positive airway pressure (CPAP). However compliance rates can be low. Methodology to improve patient tolerance to CPAP alongside with alternative, non-surgical and surgical, management strategies are discussed. All patients that fail CPAP therapy would benefit from formal upper airway evaluation by the otolaryngologist to identify any obvious causes and consider site-specific surgical therapies. Patient selection is integral to ensuring successful outcomes. A multidisciplinary team is needed to manage these patients. PMID:27867577

  2. CPAP (Continuous Positive Airway Pressure)

    MedlinePlus

    ... Clinical Trials High Blood Pressure National Center on Sleep Disorders Research Oxygen Therapy Respiratory Distress Syndrome Sleep Apnea ... This Content: Updated: December 9, 2016 Sleep Infographic Sleep Disorders & Insufficient Sleep: Improving Health through Research National Institutes ...

  3. Motivational Interviewing (MINT) Improves Continuous Positive Airway Pressure (CPAP) Acceptance and Adherence: A Randomized Controlled Trial

    ERIC Educational Resources Information Center

    Olsen, Sara; Smith, Simon S.; Oei, Tian P. S.; Douglas, James

    2012-01-01

    Objective: Adherence to continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA) is poor. We assessed the effectiveness of a motivational interviewing intervention (motivational interview nurse therapy [MINT]) in addition to best practice standard care to improve acceptance and adherence to CPAP therapy in people with…

  4. Impact of Treatment with Continuous Positive Airway Pressure (CPAP) on Weight in Obstructive Sleep Apnea

    PubMed Central

    Quan, Stuart F.; Budhiraja, Rohit; Clarke, Denise P.; Goodwin, James L.; Gottlieb, Daniel J.; Nichols, Deborah A.; Simon, Richard D.; Smith, Terry W.; Walsh, James K.; Kushida, Clete A.

    2013-01-01

    Study Objective: To determine the impact of continuous positive airway pressure (CPAP) on weight change in persons with obstructive sleep apnea (OSA). Design, Setting, and Participants: The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blinded sham-controlled multicenter clinical trial conducted at 5 sites in the United States. Of 1,105 participants with an apnea hypopnea index ≥ 10 events/ hour initially randomized, 812 had body weight measured at baseline and after 6 months of study. Intervention: CPAP or Sham CPAP. Measurements: Body weight, height, hours of CPAP or Sham CPAP use, Epworth Sleepiness Scale score. Results: Participants randomized to CPAP gained 0.35 ± 5.01 kg, whereas those on Sham CPAP lost 0.70 ± 4.03 kg (mean ± SD, p = 0.001). Amount of weight gain with CPAP was related to hours of device adherence, with each hour per night of use predicting a 0.42 kg increase in weight. This association was not noted in the Sham CPAP group. CPAP participants who used their device ≥ 4 h per night on ≥ 70% of nights gained the most weight over 6 months in comparison to non-adherent CPAP participants (1.0 ± 5.3 vs. -0.3 ± 5.0 kg, p = 0.014). Conclusions: OSA patients using CPAP may gain a modest amount of weight with the greatest weight gain found in those most compliant with CPAP. Commentary: A commentary on this article appears in this issue on page 995. Citation: Quan SF; Budhiraja R; Clarke DP; Goodwin JL; Gottlieb DJ; Nichols DA; Simon RD; Smith TW; Walsh JK; Kushida CA. Impact of treatment with continuous positive airway pressure (CPAP) on weight in obstructive sleep apnea. J Clin Sleep Med 2013;9(10):989-993. PMID:24127141

  5. Effects of nasal mask leak and heated humidification on nasal mucosa in the therapy with nasal continuous positive airway pressure (nCPAP).

    PubMed

    Fischer, Yvonne; Keck, Tilman; Leiacker, Richard; Rozsasi, Ajnacska; Rettinger, Gerhard; Gruen, Philipp M

    2008-11-01

    The purpose of this study was to determine the objective short-term influence of nasal continuous positive airway pressure (nCPAP) therapy, nasal mask leak (NML) and heated humidifiers (HH) to nasal conditioning of spontaneously breathing subjects. This was a prospective, non-randomized, non-blinded day-time study. Eighteen healthy subjects were enrolled in the study. All subjects received nCPAP therapy for 60 min in three different conditions successively: (1) nCPAP without humidification, (2) nCPAP with a defined leakage of nasal mask (slashed circle 28.3 mm2) and (3) nCPAP with HH. Nasal humidity and temperature were measured in the anterior turbinate area using a miniaturized thermocouple and a relative humidity sensor. The measurements were accomplished at the beginning of therapy, after 60, 120 and 180 min. Absolute humidity (aH) in the anterior turbinate area decreased significantly (p = 0.0075) from 17.41 +/- 3.81 mg/l (baseline) to 15.27 +/- 2.21 mg/l (nCPAP alone). With attachment of a NML, aH decreased from 15.27 mg/l not significantly (p = 0.058) to 13.77 +/- 2.28 mg/l (nCPAP and NML) compared to nCPAP alone. After addition of heated humidification to nCPAP, aH increased again from 13.77 mg/l significantly (p = 0.042) to 15.29 +/- 3.51 mg/l (nCPAP and HH) compared to aH (nCPAP+NML). No difference was found between aH (nCPAP and HH) and aH (nCPAP alone). Airway temperature did not change significantly after application of nCPAP alone, nCPAP and NML, and nCPAP and HH. These data indicate that nCPAP therapy with NML tends to have more remarkable reduction of the nasal humidity than nCPAP therapy without NML. nCPAP with heated humidifier is able to compensate the dehydration effects induced by nCPAP therapy with NML by increasing the aH at the anterior turbinate area to the levels observed during breathing with nCPAP alone.

  6. Cerebral hemodynamics in patients with obstructive sleep apnea syndrome monitored with near-infrared spectroscopy (NIRS) during positive airways pressure (CPAP) therapy: a pilot study

    NASA Astrophysics Data System (ADS)

    Zhang, Zhongxing; Schneider, Maja; Laures, Marco; Fritschi, Ursula; Lehner, Isabella; Qi, Ming; Khatami, Ramin

    2014-03-01

    In obstructive sleep apnea syndrome (OSA) the periodic reduction or cessation of breathing due to narrowing or occlusion of the upper airway during sleep leads to daytime symptoms and increased cardiovascular risk, including stroke. The higher risk of stroke is related to the impairment in cerebral vascular autoregulation. Continuous positive airways pressure (CPAP) therapy at night is the most effective treatment for OSA. However, there is no suitable bedside monitoring method evaluating the treatment efficacy of CPAP therapy, especially to monitor the recovery of cerebral hemodynamics. NIRS is ideally suited for non-invasive monitoring the cerebral hemodynamics during sleep. In this study, we will for first time assess dynamic changes of cerebral hemodynamics during nocturnal CPAP therapy in 3 patients with OSA using NIRS. We found periodic oscillations in HbO2, HHb, tissue oxygenation index (TOI) and blood volume associated with periodic apnea events without CPAP in all OSA patients. These oscillations were gradually attenuated and finally eliminated with the stepwise increments of CPAP pressures. The oscillations were totally eliminated in blood volume earlier than in other hemodynamic parameters. These results suggested that 1) the cerebral hemodynamic oscillations induced by OSA events can effectively be attenuated by CPAP therapy, and 2) blood flow and blood volume recovered first during CPAP therapy, followed by the recovery of oxygen consumption. Our study suggested that NIRS is a useful tool to evaluate the efficacy of CPAP therapy in patients with OSA bedside and in real time.

  7. Upper airway obstruction during midazolam sedation: modification by nasal CPAP.

    PubMed

    Nozaki-Taguchi, N; Isono, S; Nishino, T; Numai, T; Taguchi, N

    1995-08-01

    We examined the depressant effect of midazolam on respiration in 21 healthy women undergoing lower abdominal surgery with spinal anaesthesia. Airway gas flow, airway pressure, and the sound of snoring were recorded together with arterial oxygen saturation (SpO2). After spinal anaesthesia was established, subjects were deeply sedated with pentazocine 15 mg followed by incremental doses of midazolam 1 mg i.v. up to 0.1 mg.kg-1. When SpO2 decreased to < 90% or snoring and/or apnoea was observed, continuous positive airway pressure applied through the nose (nasal CPAP) was increased until the respiratory deterioration was reversed. While one patient remained free of respiratory events, the other 20 patients were successfully treated with nasal CPAP restoring normal SpO2 (95.5 +/- 1.7%) without snoring. Stepwise reduction of nasal CPAP determined the minimally effective CPAP to prevent snoring to be 5.1 +/- 2.1 cm H2O. Further reduction of nasal CPAP induced snoring in 15 patients and obstructive apnoea in five patients with the latter accompanied by a severe reduction of SpO2 (87.4 +/- 6.1%). Patients with apnoea were older than those who snored (P < 0.05. We conclude that upper airway obstruction contributes considerably to decreases in SpO2 during midazolam sedation for spinal anaesthesia.

  8. In vivo efficacy of heated and non-heated humidifiers during nasal continuous positive airway pressure (nCPAP)-therapy for obstructive sleep apnoea.

    PubMed

    Wiest, G H; Fuchs, F S; Brueckl, W M; Nusko, G; Harsch, I A; Hahn, E G; Ficker, J H

    2000-04-01

    Upper airway dryness is a frequent side-effect of nasal continuous positive airway pressure therapy (nCPAP) in obstructive sleep apnoea (OSA). In this situation, heated or non-heated passover humidifiers are often added to the nCPAP-therapy. The efficacy of these two modes in terms of increasing the absolute humidity of the inspired air in vivo has so far not been established. The present investigation was therefore designed to compare various heated and non-heated passover humidifiers in terms of the their ability to increase the absolute humidity in the inspired air during nCPAP. In six healthy test individuals, nCPAP-therapy at pressures of 5 mbar and 10 mbar was simulated, and the relative humidity and temperature of the air within the tube at the junction between CPAP tube and mask were measured. In each test person, measurements were carried out both with and without the two heated (HC 100, Fischer&Paykel Inc., New Zealand and HumidAire, ResMed Ltd., Australia) and two non-heated (Oasis and Humidifier, both from Respironics Inc., U.S.A.) passover humidifiers under steady-state conditions. The absolute humidity was calculated from the relative humidity and temperature measurements. The mean (SD) absolute humidity (gm(-3)) in the steady-state was significantly (P<0.05 higher with each of the humidifiers than that calculated when no humidifier was used. The relevant figures were as follows: no humidifier: 10(-2) (1.8) gm(-3) (at 5 mbar)/9.8 (1.8) gm(-3) (at 10 mbar); Humidifier: 16.4 (0.97)/15.6 (1.26); Oasis: 17.3 (0.97)/ 16.7 (0.93); HC100: 26.5 (1.40)/26.2 (1.23); HumidAire: 31.8 (2.50)/30.9 (2.64). The mean increase in absolute humidity (in gm(-3)) with the aid of the heated humidifiers was 16.3 (5 mbar) gm(-3)/16.4 (10 mbar) gm(-3) with HC100 and 21.6/21.1 with HumidAire, and in both cases was clearly and significantly (P=0.028) higher in comparison with the non-heated humidifiers--6.2/5.8 with Humidifier and 7.2/6.9 with Oasis. In terms of the absolute

  9. Continuous Positive Airway Pressure (CPAP)

    MedlinePlus

    ... Copyright © 2017 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly prohibited without prior written ... Copyright 2017. American Academy of Otolaryngology — Head and Neck Surgery 1650 Diagonal Rd Alexandria, VA 22314 tel (703) ...

  10. Adherence to Continuous Positive Airway Pressure in Existing Users: Self-Efficacy Enhances the Association between Continuous Positive Airway Pressure and Adherence

    PubMed Central

    Dzierzewski, Joseph M.; Wallace, Douglas M.; Wohlgemuth, William K.

    2016-01-01

    Study Objectives: Obstructive sleep apnea-hypopnea syndrome (OSAHS) is a common sleep disorder associated with a myriad of sequelae. OSAHS is effectively treated with continuous positive airway pressure (CPAP) therapy. However, fewer than 50% of patients are compliant with their CPAP therapy prescriptions. The current study sought to explore an integrated, biopsychological approach to CPAP adherence among experienced CPAP users. Methods: We performed a retrospective, cross-sectional analysis of a cohort of veterans with a diagnosis of OSAHS (n = 191) who were prescribed CPAP therapy and returned for adherence download at the Miami VA Sleep Clinic. The relationships between biomedical characteristics (e.g., CPAP pressure, self-reported sleepiness, and change in sleep efficiency) and psychological factors (e.g., self-efficacy beliefs and psychological diagnoses) and objectively measured CPAP use were examined to determine whether psychological factors moderated the relationships between biomedical characteristics and CPAP adherence. Results: Hierarchical regression analyses predicting CPAP adherence (adjusting for time since CPAP prescription, age, education, prescribed CPAP pressure, daytime sleepiness, changes in sleep efficiency with CPAP, and psychiatric conditions) revealed the following: (1) CPAP self-efficacy and CPAP pressure were positively related to adherence, and (2) CPAP self-efficacy moderates the relationship between CPAP pressure and CPAP adherence. Conclusions: There was no relationship between CPAP pressure and adherence in individuals with low self-efficacy beliefs. However, for individuals with high self-efficacy beliefs, there was a significant positive relationship between CPAP pressure and adherence. Self-efficacy beliefs appear to be a prime target for focused interventions aimed at improving CPAP adherence among those individuals with higher pressure prescriptions. Citation: Dzierzewski JM, Wallace DM, Wohlgemuth WK. Adherence to continuous

  11. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System.

    PubMed

    Welty, Stephen E

    2016-12-01

    Premature neonates are predisposed to complications, including bronchopulmonary dysplasia (BPD). BPD is associated with long-term pulmonary and neurodevelopmental consequences. Noninvasive respiratory support with nasal continuous positive airway pressure (CPAP) has been recommended strongly by the American Academy of Pediatrics. However, CPAP implementation has shown at least a 50% failure rate. Enhancing nasal CPAP effectiveness may decrease the need for mechanical ventilation and reduce the incidence of BPD. Bubble nasal CPAP is better than nasal CPAP using mechanical devices and the bubbling provides air exchange in distal respiratory units. The Seattle PAP system reduces parameters that assess work of breathing.

  12. Upper Airway Variation and Frequent Alcohol Consumption Can Affect Compliance With Continuous Positive Airway Pressure

    PubMed Central

    Jeong, Jong In; Kim, Hyo Yeol; Hong, Sang Duk; Ryu, Gwanghui; Kim, Su Jin; Lee, Kyung Eun; Dhong, Hun-Jong; Chung, Seung-Kyu

    2016-01-01

    Objectives Compliance with continuous positive airway pressure (CPAP) treatment remains a primary concern for improving treatment outcomes of obstructive sleep apnea. There are few studies that have considered the role of upper airway anatomy on the compliance with CPAP. We hypothesized that upper airway anatomy would influence the compliance with CPAP. Methods One hundred out of 161 consecutive patients were enrolled in this study. The following possible determinants were tested against CPAP use: demographic and anthropometric data, minimal cross-sectional area on acoustic rhinometry, cephalometric and polysomnographic data, questionnaires of Epworth sleepiness scale and Beck depression index, and histories of previous upper airway surgery, degree of nasal obstruction, daily cigarette consumption, and weekly frequency of alcohol intake. Results Univariate analysis showed that histories of previous upper airway surgery and less frequent alcohol consumption, and longer mandibular plane-hyoid length (MP-H) on cephalometry were associated with longer average daily CPAP use. After adjustment for the confounding factors with multiple linear regression analysis, alcohol consumption and MP-H were still associated with the compliance with CPAP significantly. Conclusion To improve compliance with CPAP, careful evaluations of upper airway problems and life style are important before initiating CPAP. PMID:27334512

  13. [Continuous positive airways pressure treatment for obstructive sleep apnoea].

    PubMed

    Antone, E; Gilbert, M; Bironneau, V; Meurice, J C

    2015-04-01

    Continuous positive airway pressure (CPAP) still remains the most frequently used and the most efficient treatment for obstructive sleep apnea syndrome. However, its efficiency is conditioned by healthcare quality depending on many factors such as medical specificities of the patients as well as the severity of sleep-related breathing disorders. In order to optimize CPAP efficiency, it is necessary to be aware of the functional abilities of the different devices, and to perform a close monitoring of the patients, particularly during the first weeks of treatment, by maximally using the data provided by the CPAP apparatus. Some questions remain unsolved, such as the impact of nasal CPAP on glucose metabolism or cardiovascular prognosis. Furthermore, the strategy of CPAP use should be improved according to future results of studies dedicated to the interest of home telemonitoring and taking into account the validated mode of CPAP initiation.

  14. Blood Pressure Increases in OSA due to Maintained Neurovascular Sympathetic Transduction: Impact of CPAP

    PubMed Central

    Tamisier, Renaud; Tan, Can Ozan; Pepin, Jean-Louis; Levy, Patrick; Taylor, J. Andrew

    2015-01-01

    Study Objectives: To test the hypothesis that greater resting sympathetic activity in obstructive sleep apnea (OSA) syndrome would not induce a lesser sympathetic neurovascular transduction. Design: Case-controlled cohort study. Participants: 33 patients with newly diagnosed OSA without comorbidities and 14 healthy controls. Interventions: 6 months of continuous positive airway pressure (CPAP) treatment for OSA patients and follow-up for 9 healthy controls. Measurements and Results: We assessed resting sympathetic outflow and sympathetic neurovascular transduction. Sympathetic activity was directly measured (microneurography) at rest and in response to sustained isometric handgrip exercise. Neurovascular transduction was derived from the relationship of sympathetic activity and blood pressure to leg blood flow during exercise. Despite an elevated sympathetic activity of ∼50% in OSA compared to controls, neurovascular transduction was not different (i.e., absence of tachyphylaxis). After six months of CPAP, there were significant declines in diastolic pressure, averaging ∼4 mm Hg, and in sympathetic activity, averaging ∼20% with no change in transduction. Conclusions: Greater sympathetic activity in obstructive sleep apnea does not appear to be associated with lesser neurovascular transduction. Hence, elevated sympathetic outflow without lesser transduction may underlie the prevalent development of hypertension in this population that is well controlled by continuous positive airway pressure treatment. Citation: Tamisier R, Tan CO, Pepin JL, Levy P, Taylor JA. Blood pressure increases in OSA due to maintained neurovascular sympathetic transduction: impact of CPAP. SLEEP 2015;38(12):1973–1980. PMID:26039959

  15. Patient Education Combined in a Music and Habit-Forming Intervention for Adherence to Continuous Positive Airway (CPAP) Prescribed for Sleep Apnea

    PubMed Central

    Smith, Carol E.; Dauz, Emily; Clements, Faye; Werkowitch, Marilyn; Whitman, Robert

    2009-01-01

    Objective As many as 50% of patients diagnosed with obstructive sleep apnea stop adhering to the prescribed medical treatment of CPAP (Continuous Positive Airway Pressure) within one to three weeks of onset. Thus, a theory based intervention using music to support habit formation was designed to improve CPAP adherence at onset. The intervention materials included directions for CPAP nightly use, a diary for recording nightly use and writing about CPAP benefits or problems. In addition, an audiotape with softly spoken instructions for placing the CPAP mask comfortably, using deep breathing and muscle relaxation along with the slowly decreasing music tempo was provided to listen to at bedtime each night. Methods Effects of this music intervention were tested in a randomized, placebo-controlled trial of 97 patients with 53 males (55%) and 44 females (45%). Moderate to severe apnea/hyponea scores (per sleep laboratory data) and medical diagnosis of OSA were required for study inclusion. Results Compared to placebo controls, a greater proportion of experimental patients were adhering (χ2=14.67, p<.01; a large difference, Phi=.39) at the end of the first month of CPAP onset. There were no differences in CPAP adherence at 3 (X2=.065, p=.79) and 6 (X2=.118, p=.73) months. Patients’ diary data and satisfaction survey results indicated the intervention was rated as helpful and guided formation of a relaxing, habitual routine of CPAP nightly use. Conclusion The intervention had a strong effect for improving adherence to CPAP at 1 month. Practice Implications Adherence at the onset of treatment is critical and the audio music intervention was easily administered. Other interventions that target problems interfering with longer-term CPAP adherence are needed. PMID:18829212

  16. Comparison of Efficacy and Tolerance of Automatic Continuous Positive Airway Pressure Devices With the Optimum Continuous Positive Airway Pressure.

    PubMed

    Tommi, George; Aronow, Wilbert S; Sheehan, John C; McCleay, Matthew T; Meyers, Patrick G

    Patients diagnosed with obstructive sleep apnea syndrome were randomly placed on automatic continuous positive airway pressure (ACPAP) for 2 hours followed by manual titration for the rest of the night. One hundred sixty-one patients entered the study, with at least 50 patients titrated with each of 3 ACPAP devices. The optimum continuous positive airway pressure (CPAP) was defined as the lowest pressure with an apnea-hypoxia index of ≤5/hr, which ranged from 4 cm to 18 cm. Success with ACPAP was approximately 60%-80% when the optimum CPAP was 4-6 cm but fell to below 30% if the optimum CPAP was ≥8 cm (P = 0.001). Average ACPAP ranged from 2 to 10 cm below the optimum level if the optimum CPAP was ≥8 cm. Patients who responded to a low CPAP but deteriorated on higher pressures failed to respond to any of the automatic devices. We recommend that CPAP titration be performed manually before initiation of ACPAP in patients with obstructive sleep apnea. The basal pressure for ACPAP should be the optimum pressure obtained by manual titration. Limits on the upper level of ACPAP may be necessary for patients who deteriorate on higher positive pressures.

  17. Adherence to Continuous Positive Airway Pressure Treatment for Obstructive Sleep Apnea: Implications for Future Interventions

    PubMed Central

    Weaver, Terri E.; Sawyer, Amy M.

    2010-01-01

    Adherence to continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) is a critical problem with adherence rates ranging from 30–60%. Poor adherence to CPAP is widely recognized as a significant limiting factor in treating OSA, reducing the overall effectiveness of the treatment and leaving many OSA patients at heightened risk for comorbid conditions, impaired function and quality of life. The extant literature examining adherence to CPAP provides critical insight to measuring adherence outcomes, defining optimal adherence levels, and predicting CPAP adherence. This research has revealed salient factors that are associated with or predict CPAP adherence and may guide the development of interventions to promote CPAP adherence. Over the past 10 years, intervention studies to promote CPAP adherence have incorporated a multitude of strategies including education, support, cognitive behavioral approaches, and mixed strategies. This review of the current state of science of CPAP adherence will (1) synthesize the extant literature with regard to measuring, defining, and predicting CPAP adherence, (2) review published intervention studies aimed at promoting CPAP adherence, and (3) suggest directions for future empiric study of adherence to CPAP that will have implications for translational science. Our current understanding of CPAP adherence suggests that adherence is a multi-factorial, complex clinical problem that requires similarly designed approaches to effectively address poor CPAP adherence in the OSA population. PMID:20308750

  18. Bubble–CPAP vs. Ventilatory–CPAP in Preterm Infants with Respiratory Distress

    PubMed Central

    Bahman-Bijari, Bahareh; Malekiyan, Arash; Niknafs, Pedram; Baneshi, Mohammad-Reza

    2011-01-01

    Objective Application of Continuous Positive Airway Pressure (CPAP) in neonate with respiratory distress is associated with reduction of respiratory failure, reduced complications and mortality. Bubble CPAP (B-CPAP) and ventilator-derived CPAP (V-CPAP) are two most popular CPAP modes. We aimed to determine whether B-CPAP and V-CPAP would have different survival rate and possible complications. Methods This prospective clinical trial was performed on 50 preterm neonates weighing 1000-2000 gr who were admitted to the neonatal intensive care unit of Afzalipoor Hospital because of respiratory distress between June 2009 and May 2010. Patients were randomly allocated into treatment groups using minimization technique. Survival analysis was applied to estimate and compare survival rates. Duration of oxygen therapy, hospital stay as well as hospitalization costs were compared using independent sample t-test. Findings Estimated survival rates at 24 hours in B-CPAP and V-CPAP groups were 100% and 77% respectively. Corresponding figures at 48 hours were 100% and 71%. In addition the hospitalization cost in V-CPAP group was significantly higher than in B-CPAP group. Conclusion According to our results, B-CPAP was effective in the treatment of neonates who were suffering from respiratory distress and reduced the duration of hospital stay. In addition to mentioned benefits, its low cost may be the reason to use B-CPAP broadly compared with V-CPAP. PMID:23056781

  19. Established vascular effects of continuous positive airway pressure therapy in patients with obstructive sleep apnoea—an update

    PubMed Central

    Wons, Annette Marie

    2015-01-01

    The aim of this review was to summarize the current data from randomised controlled trials (RCTs) on vascular effects of continuous positive airway pressure (CPAP) therapy in patients with obstructive sleep apnoea (OSA). There is good evidence from RCTs that CPAP lowers blood pressure (BP) to a clinically significant amount. The effect seems to be dependent on the hours of nightly CPAP usage. Data from RCTs have also proven a beneficial effect of CPAP on measures of vascular function such as endothelial function and arterial stiffness. However, there is still a lack of evidence from RCTs proving that CPAP reduces vascular events and mortality. PMID:26101649

  20. Blood pressure effects of CPAP in nonresistant and resistant hypertension associated with OSA: A systematic review of randomized clinical trials.

    PubMed

    Feldstein, Carlos A

    Obstructive sleep apnea (OSA) is a rather common chronic disorder, associated with increased prevalence of hypertension. The pathophysiological mechanisms for hypertension in OSA are at least in part linked to intermittent hypoxia developed during nightly hypopneas and apneas. Hypoxemia stimulates sympathetic overactivity, systemic inflammation, oxidative stress, and endothelial dysfunction. However, it appears that intermittent hypoxemia is not the only factor in the development of hypertension in OSA. Supplemental oxygen therapy that improved oxyhemoglobin saturation to similar levels to those achieved with CPAP treatment did not reduce BP. In this scenario, it could be proposed that hypoxemia acts as a trigger of sympathetic overdrive, which when set is the main factor in the development of hypertension in OSA. This review appraises evidence provided by randomized controlled trials on the BP-lowering effectiveness of continuous positive airway pressure (CPAP) treatment of OSA patients with nonresistant and resistant hypertension. It suggests that CPAP treatment is more effective in treating resistant hypertension than nonresistant hypertension. A possible explanation is that sympathetic overactivity and altered vascular reactivity in OSA could be more severe in resistant hypertension than in nonresistant hypertension. An intricate interaction among compliance, adherence, and their interaction with demographic characteristics, genetic factors, and comorbidities of the population included might explain the differences found between trials on their influence over the antihypertensive effectiveness of CPAP. Further long-term trials are needed in hypertensive OSA patients to assess whether CPAP treatment in OSA patients consistently restores physiological nocturnal BP fall and adjusts resting and circadian heart rate.

  1. A simple circuit to deliver bubbling CPAP.

    PubMed

    Kaur, Charanjit; Sema, Akatoli; Beri, Rajbir S; Puliyel, Jacob M

    2008-04-01

    Nasal continuous positive airway pressure (CPAP), especially bubbling CPAP, is known to reduce the need for more invasive ventilation. We here describe a circuit that can deliver bubbling CPAP in resource poor settings. We describe how the oxygen concentration can be altered from 98% to 21% oxygen using this system. Addition of a humidifier in the circuit has the effect of reducing the oxygen concentration by 1 to 5%. The cost of putting together the system is approximately Rs 5000.

  2. Polysomnographic predictors of persistent continuous positive airway pressure adherence in patients with moderate and severe obstructive sleep apnea.

    PubMed

    Chen, Yung-Fu; Hang, Liang-Wen; Huang, Chun-Sen; Liang, Shinn-Jye; Chung, Wei-Sheng

    2015-02-01

    Extensive use of continuous positive airway pressure (CPAP) has positive clinical benefits for most patients with obstructive sleep apnea (OSA). However, patient adherence is a major limiting factor to the effectiveness of CPAP treatment. This study determined the potential and quantifiable factors affecting the willingness of patients with OSA to undertake CPAP treatment by comparing the polysomnographic parameters recorded during diagnosis and titration. Patients with moderate and severe OSA who attended diagnostic polysomnography (PSG) and CPAP titration at the sleep center of China Medical University Hospital (CMUH) were included in the study. A total of 312 patients were divided into persistent users and nonusers of CPAP according to their use of in-home CPAP following titration and a 7-day CPAP trial. Multivariate logistic regression analyses were used to define the potential polysomnographic predictors of persistent CPAP adherence, and odds ratios (ORs) and 95% confidence intervals (CIs) were calculated. Most patients were men older than 50 years who were overweight or obese. Among the patients, 146 (46.8%) became persistent CPAP users. A 10% improvement of oxygen desaturation index (ODI) and a 10% increment in deep sleep percentage increased the chance of persistent CPAP use 1.18-fold and 1.07-fold, respectively. In addition, the improved ODI and deep sleep during CPAP titration increased the chance of persistent CPAP user. The polysomnographic parameters obtained from diagnosis and during titration can facilitate the prediction of persistent CPAP use.

  3. Graded exposure therapy for addressing claustrophobic reactions to continuous positive airway pressure: a case series report.

    PubMed

    Means, Melanie K; Edinger, Jack D

    2007-01-01

    Continuous positive airway pressure (CPAP) is a safe, effective treatment for obstructive sleep apnea, and yet many patients develop claustrophobic reactions to the CPAP nasal mask and cannot tolerate this treatment. We examined the efficacy of a graded in-vivo exposure therapy for enhancing CPAP adherence using a retrospective, case series design. Objective CPAP adherence data were obtained on clinical patients who attended 1 or more sessions of exposure therapy with a behavioral sleep psychologist. Compared to pre-treatment, patients used CPAP significantly longer after exposure therapy. No predictors of treatment response were identified. CPAP exposure therapy may be beneficial in some cases; however, further research is needed to determine types of patients most likely to benefit from this therapy.

  4. Effects of nasal continuous positive airway pressure and oxygen supplementation on norepinephrine kinetics and cardiovascular responses in obstructive sleep apnea.

    PubMed

    Mills, Paul J; Kennedy, Brian P; Loredo, Jose S; Dimsdale, Joel E; Ziegler, Michael G

    2006-01-01

    Obstructive sleep apnea (OSA) is characterized by noradrenergic activation. Nasal continuous positive airway pressure (CPAP) is the treatment of choice and has been shown to effectively reduce elevated norepinephrine (NE) levels. This study examined whether the reduction in NE after CPAP is due to an increase in NE clearance and/or a decrease of NE release rate. Fifty CPAP-naive OSA patients with an apnea-hypopnea index >15 were studied. NE clearance and release rates, circulating NE levels, urinary NE excretion, and blood pressure and heart rate were determined before and after 14 days of CPAP, placebo CPAP (CPAP administered at ineffective pressure), or oxygen supplementation. CPAP led to a significant increase in NE clearance (P < or = 0.01), as well as decreases in plasma NE levels (P < or = 0.018) and daytime (P < 0.001) and nighttime (P < 0.05) NE excretion. NE release rate was unchanged with treatment. Systolic (P < or = 0.013) and diastolic (P < or = 0.026) blood pressure and heart rate (P < or = 0.014) were decreased in response to CPAP but not in response to oxygen or placebo CPAP treatment. Posttreatment systolic blood pressure was best predicted by pretreatment systolic blood pressure and posttreatment NE clearance and release rate (P < 0.01). The findings indicate that one of the mechanisms through which CPAP reduces NE levels is through an increase in the clearance of NE from the circulation.

  5. Continuous positive airway pressure treatment for acute mountain sickness at 4240 m in the Nepal Himalaya.

    PubMed

    Johnson, Pamela L; Johnson, Claire C; Poudyal, Prasanta; Regmi, Nirajan; Walmsley, Megan A; Basnyat, Buddha

    2013-09-01

    Acute mountain sickness (AMS) is very common at altitudes above 2500 m. There are few treatment options in the field where electricity availability is limited, and medical assistance or oxygen is unavailable or difficult to access. Positive airway pressure has been used to treat AMS at 3800 m. We hypothesized that continuous positive airway pressure (CPAP) could be used under field conditions powered by small rechargeable batteries. Methods Part 1. 5 subjects trekked to 3500 m from 2800 m in one day and slept there for one night, ascending in the late afternoon to 3840 m, where they slept using CPAP 6-7 cm via mask. The next morning they descended to 3500 m, spent the day there, ascended in late afternoon to 3840 m, and slept the night without CPAP. Continuous overnight oximetry was recorded and the Lake Louise questionnaire for AMS administered both mornings. Methods Part 2. 14 trekkers with symptoms of AMS were recruited at 4240 m. All took acetazolamide. The Lake Louise questionnaire was administered, oximetry recorded, and CPAP 6-7 cm was applied for 10-15 min. CPAP was used overnight and oximetry recorded continuously. In the morning the Lake Louise questionnaire was administered, and oximetry recorded for 10-15 min. The equipment used in both parts was heated, humidified Respironics RemStar® machines powered by Novuscell™ rechargeable lithium ion batteries. Oximetry was recorded using Embletta™ PDS. Results Part 1. CPAP improved overnight Sao2 and eliminated AMS symptoms in the one subject who developed AMS. CPAP was used for 7-9 h and the machines operated for >8 h using the battery. Results Part 2. CPAP use improved Sao2 when used for 10-15 min at the time of recruitment and overnight CPAP use resulted in significantly reduced AMS symptoms. Conclusion. CPAP with rechargeable battery may be a useful treatment option for trekkers and climbers who develop AMS.

  6. Blood Pressure and Metabolic Changes After 3-Month CPAP Therapy in a Very Elderly Obese with Severe Obstructive Sleep Apnea: A Case Report and Review of the Literature.

    PubMed

    Spannella, Francesco; Giulietti, Federico; Di Pentima, Chiara; Lombardi, Francesca Elena; Borioni, Elisabetta; Sarzani, Riccardo

    2017-03-21

    Age is one of the main risk factor for the presence of obstructive sleep apnea (OSA). This syndrome is associated with hypertension, cardiovascular disease, cognitive impairment and metabolic abnormalities, such as type 2 diabetes. Continuous positive airway pressure (CPAP) represents the gold standard therapy, but its benefit is still to be determined in very elderly. We report the blood pressure and metabolic changes in a very elderly obese with severe OSA after 3-month CPAP therapy. We have evaluated a very elderly obese male affected by severe symptomatic OSA, poor controlled nocturnal hypertension and insulin resistance. After 3-month CPAP therapy, without any changes in drug therapy, we observed a normalization of circadian blood pressure (BP) pattern, an improved insulin sensitivity, together with a reduced resting energy expenditure, despite no significant change in weight. This case report shows the benefits of OSA treatment with CPAP, not only on BP profile, but also on metabolic parameters in a very elderly, a particular type of patient in which scientific evidence is still scant. Further studies are needed to better investigate the relationship between OSA, CPAP therapy and energy expenditure not only in adults but also in elderly patients.

  7. Alternative methods of titrating continuous positive airway pressure: a large multicenter study.

    PubMed

    Masa, Juan F; Jiménez, Antonio; Durán, Joaquín; Capote, Francisco; Monasterio, Carmen; Mayos, Mercedes; Terán, Joaquín; Hernández, Lourdes; Barbé, Ferrán; Maimó, Andrés; Rubio, Manuela; Montserrat, José M

    2004-12-01

    Standard practice for continuous positive airway pressure (CPAP) treatment in sleep apnea and hypopnea syndrome (SAHS) requires pressure titration during attended laboratory polysomnography. However, polysomnographic titration is expensive and time-consuming. The aim of this study was to ascertain, in a large sample of CPAP-naive patients, whether CPAP titration performed by an unattended domiciliary autoadjusted CPAP device or with a predicted formula was as effective as CPAP titration performed by full polysomnography. The main outcomes were the apnea-hypopnea index and the subjective daytime sleepiness. We included 360 patients with SAHS requiring CPAP treatment. Patients were randomly allocated into three groups: standard, autoadjusted, and predicted formula titration with domiciliary adjustment. The follow-up period was 12 weeks. With CPAP treatment, the improvement in subjective sleepiness and apnea-hypopnea index was very similar in the three groups. There were no differences in the objective compliance of CPAP treatment and in the dropout rate of the three groups at the end of the follow-up. Autoadjusted titration at home and predicted formula titration with domiciliary adjustment can replace standard titration. These procedures could lead to considerable savings in cost and to significant reductions in the waiting list.

  8. Meta-analysis of randomised controlled trials of oral mandibular advancement devices and continuous positive airway pressure for obstructive sleep apnoea-hypopnoea

    PubMed Central

    Sharples, Linda D.; Clutterbuck-James, Abigail L.; Glover, Matthew J.; Bennett, Maxine S.; Chadwick, Rebecca; Pittman, Marcus A.; Quinnell, Timothy G.

    2017-01-01

    Summary Obstructive sleep apnoea-hypopnoea (OSAH) causes excessive daytime sleepiness, impairs quality-of-life, and increases cardiovascular disease and road traffic accident risks. Continuous positive airway pressure (CPAP) treatment and mandibular advancement devices (MAD) have been shown to be effective in individual trials but their effectiveness particularly relative to disease severity is unclear. A MEDLINE, Embase and Science Citation Index search updating two systematic reviews to August 2013 identified 77 RCTs in adult OSAH patients comparing: MAD with conservative management (CM); MAD with CPAP; or CPAP with CM. Overall MAD and CPAP significantly improved apnoea-hypopnoea index (AHI) (MAD −9.3/hr (p < 0.001), CPAP −25.4 (p < 0.001)). In direct comparisons mean AHI and Epworth sleepiness scale score were lower (7.0/hr (p < 0.001) and 0.67 (p = 0.093) respectively) for CPAP. There were no CPAP vs. MAD trials in mild OSAH but in comparisons with CM, MAD and CPAP reduced ESS similarly (MAD 2.01 (p < 0.001); CPAP 1.23 (p = 0.012). Both MAD and CPAP are clinically effective in the treatment of OSAH. Although CPAP has a greater treatment effect, MAD is an appropriate treatment for patients who are intolerant of CPAP and may be comparable to CPAP in mild disease. PMID:26163056

  9. Impact of Randomization, Clinic Visits, and Medical and Psychiatric Cormorbidities on Continuous Positive Airway Pressure Adherence in Obstructive Sleep Apnea

    PubMed Central

    Budhiraja, Rohit; Kushida, Clete A.; Nichols, Deborah A.; Walsh, James K.; Simon, Richard D.; Gottlieb, Daniel J.; Quan, Stuart F.

    2016-01-01

    Study Objectives: To evaluate factors associated with continuous positive airway pressure (CPAP) adherence in patients with obstructive sleep apnea (OSA) in the Apnea Positive Pressure Long-term Efficacy Study (APPLES) cohort. Methods: The data from a prospective 6-mo multicenter randomized controlled trial with 558 subjects randomized to active CPAP and 547 to sham CPAP were analyzed to assess adherence to CPAP during first 2 mo (early period) and during months 5-6 (late period). Results: Participants randomized to active CPAP had higher hours of nightly adherence compared to the sham CPAP group at both 2 (4.9 ± 2.0 h versus 4.07 ± 2.14 h, p < 0.001) and 6 mo (4.70 ± 2.08 h versus 3.41 ± 2.19 h, p < 0.001). Those assigned to sham CPAP were more likely to correctly identify their treatment group (70.0% versus 55.2%, p < 0.001). Irrespective of treatment group assignment, those who believed they were receiving active CPAP had higher hours of adherence than those who thought they were in the sham CPAP group at both 2 mo (4.91 ± 2.01 versus 4.17 ± 2.17, p < 0.001) and 6 mo (4.65 ± 2.10 versus 3.65 ± 2.22, p < 0.001). Among those randomized to active CPAP, older age was significantly related to CPAP use > 4 h per night. Presence of cardiovascular disorders was associated with higher hours of CPAP use, whereas presence of anxiety was associated with a trend toward lower hours of CPAP use. Presence of nasal congestion was associated with a decrease in mean daily CPAP use between the early and the late adherence period. The adherence during the week prior to a clinic visit was higher than the average adherence during the 2-mo period prior to the visit. Conclusions: Randomization to active therapy, belief that one is in the active treatment group, older age, and possibly presence of cardiovascular disorders are positively linked to CPAP adherence. Nasal congestion and anxiety are negatively associated with CPAP adherence. CPAP nightly usage increases as clinic

  10. Correlates of Pediatric CPAP Adherence

    PubMed Central

    Hawkins, Stephen M.M.; Jensen, Emily L.; Simon, Stacey L.; Friedman, Norman R.

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is a common pediatric condition characterized by recurrent partial or complete cessation of airflow during sleep, typically due to inadequate upper airway patency. Continuous positive airway pressure (CPAP) is a therapeutic option that reduces morbidity. Despite efforts to promote use, CPAP adherence is poor in both pediatric and adult populations. We sought to determine whether demographics, insurance status, OSA severity, therapeutic pressure, or comorbid conditions were associated with pediatric CPAP adherence. Methods: A retrospective review of adherence download data was performed on all pediatric patients with initiation or adjustment of CPAP treatment over a one-year period with documented in-laboratory CPAP titration. Patients were grouped as CPAP adherent or non-adherent, where adherence was defined as > 70% nightly use and average usage ≥ 4 hours per night. Differences between the groups were analyzed by χ2 test. Results: Overall, nearly half of participants were CPAP adherent (49%, 69/140). Of the demographic data collected (age, ethnicity, sex, insurance status), only female sex was associated with better adherence (60.9% vs 39.5% of males adherent; odds ratio [OR] = 2.41, 95%CI = 1.20–4.85; p = 0.01). Severity of OSA (diagnostic apnea-hypopnea index [AHI] and degree of hypoxemia), therapeutic pressure, and residual AHI did not impact CPAP adherence (p > 0.05). Patients with developmental delay (DD) were more likely to be adherent with CPAP than those without a DD diagnosis (OR = 2.55, 95%CI = 1.27–5.13; p = 0.007). Female patients with trisomy 21 tended to be more adherent, but this did not reach significance or account for the overall increased adherence associated with female sex. Conclusions: Our study demonstrates that adherence to CPAP therapy is poor but suggests that female sex and developmental delay are associated with better adherence. These findings support efforts to understand the

  11. Meta-analysis of randomised controlled trials of oral mandibular advancement devices and continuous positive airway pressure for obstructive sleep apnoea-hypopnoea.

    PubMed

    Sharples, Linda D; Clutterbuck-James, Abigail L; Glover, Matthew J; Bennett, Maxine S; Chadwick, Rebecca; Pittman, Marcus A; Quinnell, Timothy G

    2016-06-01

    Obstructive sleep apnoea-hypopnoea (OSAH) causes excessive daytime sleepiness, impairs quality-of-life, and increases cardiovascular disease and road traffic accident risks. Continuous positive airway pressure (CPAP) treatment and mandibular advancement devices (MAD) have been shown to be effective in individual trials but their effectiveness particularly relative to disease severity is unclear. A MEDLINE, Embase and Science Citation Index search updating two systematic reviews to August 2013 identified 77 RCTs in adult OSAH patients comparing: MAD with conservative management (CM); MAD with CPAP; or CPAP with CM. Overall MAD and CPAP significantly improved apnoea-hypopnoea index (AHI) (MAD -9.3/hr (p < 0.001), CPAP -25.4 (p < 0.001)). In direct comparisons mean AHI and Epworth sleepiness scale score were lower (7.0/hr (p < 0.001) and 0.67 (p = 0.093) respectively) for CPAP. There were no CPAP vs. MAD trials in mild OSAH but in comparisons with CM, MAD and CPAP reduced ESS similarly (MAD 2.01 (p < 0.001); CPAP 1.23 (p = 0.012). Both MAD and CPAP are clinically effective in the treatment of OSAH. Although CPAP has a greater treatment effect, MAD is an appropriate treatment for patients who are intolerant of CPAP and may be comparable to CPAP in mild disease.

  12. Effect of Continuous Positive Airway Pressure on Airway Inflammation and Oxidative Stress in Patients with Obstructive Sleep Apnea

    PubMed Central

    Tichanon, Promsrisuk; Sopida, Santamit; Orapin, Pasurivong; Watchara, Boonsawat; Banjamas, Intarapoka

    2016-01-01

    Background. Airway inflammation and oxidative stress may be linked in obstructive sleep apnea (OSA) patients. We determined the effectiveness of continuous positive airway pressure (CPAP) therapy in reducing fractional exhaled nitric oxide (FeNO) and malondialdehyde (MDA) levels in OSA patients. Methods. Thirteen patients with OSA and 13 normal controls were recruited. FeNO and MDA levels were measured in the controls and in OSA patients before and after three months of CPAP therapy. Results. FeNO and MDA levels were higher in the patients compared to the age and gender matched controls (FeNO: 25.9 ± 5.0 versus 17.5 ± 5.9 ppb, P < 0.001; MDA: 14.6 ± 7.8 versus 2.1 ± 0.3 μmol/L, P < 0.001). FeNO and MDA levels were lower post-CPAP compared to pre-CPAP (FeNO: 25.9 ± 5.0 versus 17.0 ± 2.3 ppb, P < 0.001; MDA: 14.6 ± 7.8 versus 10.0 ± 6.4 μmol/L, P < 0.01). Apnea-hypopnea index (15.9 ± 6.6 versus 4.1 ± 2.1/h, P < 0.001) and mean arterial pressure (P < 0.01) decreased following CPAP treatment. Daytime mean SpO2 (P < 0.05) increased. Conclusion. Our study demonstrates that CPAP therapy yields clinical benefits by reducing upper airway inflammation and oxidative stress in OSA patients. PMID:27445526

  13. Continuous Positive Airway Pressure and Breathlessness in Obese Patients with Obstructive Sleep Apnea: A Pilot Study

    PubMed Central

    Xiao, Sichang; Bastianpillai, Johan; Ratneswaran, Culadeeban; Pengo, Martino F.; Luo, Yuanming; Jolley, Caroline J.; Moxham, John; Steier, Joerg

    2016-01-01

    Study Objectives: Continuous positive airway pressure (CPAP) is an effective treatment for obstructive sleep apnea (OSA). However, long-term compliance with CPAP is limited. We tested the hypothesis that CPAP levels routinely used during sleep increase neural respiratory drive (NRD) and breathlessness, which may discourage compliance. Methods: This was an observational physiological cohort study in a respiratory physiology and sleep unit, University Hospital. Patients with a body mass index (BMI) > 25 kg/m2 and confirmed OSA were studied supine and awake on CPAP (4–20 cm H2O, increments of 2 cm H2O/3 min). We measured NRD during awake CPAP titration in obese subjects to quantify the response to the load of the respiratory system and compared it to the CPAP used for nocturnal treatment, with the modified Borg Scale (mBorg) for dyspnea recorded (from 0 to 10 points, with higher numbers indicating more breathlessness). Results: Fifteen patients (age 48 ± 10 years, 12 male, BMI 38.9 ± 5.8 kg/m2) with OSA (AHI 32.2 ± 21.1/h, 95th percentile of CPAP 14.1 ± 3.8 cm H2O) were studied and NRD (electromyogram of the parasternal intercostals, EMGpara; EMG of the external oblique, EMGabdomen) was recorded (awake, supine). Awake, EMGpara declined from baseline to 70.2% ± 17.1% when CPAP of 10.7 ± 3.4 cm H2O (P = 0.026) was applied. Further increase in CPAP led to a rise in EMGpara and increased breathlessness (P = 0.02). CPAP compliance (nights used) correlated negatively with mBorg scores (r = −0.738, P = 0.006). Conclusions: Awake, the respiratory system is maximally offloaded with lower than therapeutic CPAP levels in obese patients with OSA. Levels of NRD observed at effective CPAP levels while asleep are associated with breathlessness which may limit long-term CPAP compliance. Citation: Xiao S, Bastianpillai J, Ratneswaran C, Pengo MF, Luo Y, Jolley CJ, Moxham J, Steier J. Continuous positive airway pressure and breathlessness in obese patients with obstructive

  14. Sleep · 7: Positive airway pressure therapy for obstructive sleep apnoea/hypopnoea syndrome

    PubMed Central

    Gordon, P; Sanders, M

    2005-01-01

    The use of continuous positive airway pressure (CPAP) in treating symptoms associated with OSAHS is reviewed. Although it is an imperfect intervention, it continues to evolve and improve in such a way that patients who would not have been able to use this treatment even in the recent past can benefit from it today. PMID:15618587

  15. Randomised controlled crossover trial of humidified continuous positive airway pressure in mild obstructive sleep apnoea

    PubMed Central

    Marshall, N; Neill, A; Campbell, A; Sheppard, D

    2005-01-01

    Background: It is unclear whether continuous positive airway pressure (CPAP), the treatment of choice for severe obstructive sleep apnoea (OSA), is effective at improving outcomes in mild OSA. Methods: To help define the role of humidified CPAP in mild OSA, a randomised crossover study was undertaken of patients with an apnoea hypopnoea index (AHI) of 5–30/hour. Subjective sleepiness, objective wakefulness, mood, reaction time, and quality of life were measured at baseline, after 3 weeks treatment with humidified CPAP and 3 weeks sham CPAP (2 week washout). Results: Twenty nine of 31 enrolled patients (age 25–67 years, seven women, mean (SD) body mass index 31.5 (6) kg/m2) completed the protocol. Humidified CPAP improved polysomnographic indices of OSA and Epworth Sleepiness Scale (2.4 points (95% CI 0.6 to 4.2)). Objective wakefulness (modified maintenance of wakefulness test) showed a trend towards improvement (5.2 minutes (95% CI –0.6 to 11)). Mood (Hospital Anxiety and Depression Scale), quality of life (SF 36, Functional Outcomes of Sleep Questionnaire), and reaction times (Psychomotor Vigilance Task) were not improved more than sham CPAP. Compliance with humidified and sham CPAP both averaged 4.9 hours/night. Placebo effects were evident in many outcomes and there was no clear treatment preference. Conclusions: Humidified CPAP improves subjective sleepiness and possibly objective wakefulness but not reaction times, quality of life, or mood. These results do not support the routine use of CPAP in all patients with mild OSA, but offers some support for the trialling of CPAP in those with severe sleepiness. PMID:15860720

  16. Continuous Positive Airway Pressure Device Time to Procurement in a Disadvantaged Population.

    PubMed

    DelRosso, Lourdes M; Hoque, Romy; Chesson, Andrew L

    2015-01-01

    Introduction. The management of obstructive sleep apnea (OSA) in patients who cannot afford a continuous positive airway pressure (CPAP) device is challenging. In this study we compare time to CPAP procurement in three groups of patients diagnosed with OSA: uninsured subsidized by a humanitarian grant (Group 1), uninsured unsubsidized (Group 2), and those with Medicare or Medicaid (Group 3). We evaluate follow-up and adherence in Group 1. We hypothesize that additional factors, rather than just the ability to obtain CPAP, may uniquely affect follow-up and adherence in uninsured patients. Methods. 30 patients were in Groups 1 and 2, respectively. 12 patients were in Group 3. Time of CPAP procurement from OSA diagnosis to CPAP initiation was assessed in all groups. CPAP adherence data was collected for Group 1 patients at 1, 3, 6, and 9 months. Results. There were no significant differences between groups in gender, age, body mass index, or apnea hypopnea index. The mean time to procurement in Group 1 was shorter compared to Group 2 but not significant. Compared to both Group 1 and Group 2, Group 3 patients had significantly shorter times to device procurement. Conclusion. Time to procurement of CPAP was significantly shorter in those with Medicaid/Medicare insurance compared to the uninsured.

  17. Effects of continuous positive airway pressure on energy balance regulation: a systematic review

    PubMed Central

    Shechter, Ari

    2016-01-01

    Obesity is both a cause and a possible consequence of obstructive sleep apnoea (OSA), as OSA seems to affect parameters involved in energy balance regulation, including food intake, hormonal regulation of hunger/satiety, energy metabolism and physical activity. It is known that weight loss improves OSA, yet it remains unclear why continuous positive airway pressure (CPAP) often results in weight gain. The goal of this systematic review is to explore if and how CPAP affects the behaviour and/or metabolism involved in regulating energy balance. CPAP appears to correct for a hormonal profile characterised by abnormally high leptin and ghrelin levels in OSA, by reducing the circulating levels of each. This is expected to reduce excess food intake. However, reliable measures of food intake are lacking, and not yet sufficient to make conclusions. Although studies are limited and inconsistent, CPAP may alter energy metabolism, with reports of reductions in resting metabolic rate or sleeping metabolic rate. CPAP appears to not have an appreciable effect on altering physical activity levels. More work is needed to characterise how CPAP affects energy balance regulation. It is clear that promoting CPAP in conjunction with other weight loss approaches should be used to encourage optimal outcomes in OSA patients. PMID:27824596

  18. Gel pillow designed specifically for obstructive sleep apnea treatment with continuous positive airway pressure

    PubMed Central

    Salvaggio, Adriana; Lo Bue, Anna; Isidoro, Serena Iacono; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-01-01

    ABSTRACT Objective: To determine whether the use of a gel pillow with side cutouts designed to accommodate a continuous positive airway pressure (CPAP) mask and reduce head temperature improves the efficacy of and adherence to auto-CPAP therapy. Methods: Twenty-three consecutive CPAP-naïve patients with obstructive sleep apnea were enrolled in the study. Patients were given an auto-CPAP machine with an appropriate CPAP mask and were instructed to use CPAP for 15 nights. They were instructed to sleep with their own pillow (the control pillow) from nights 1 to 5 and with either a foam pillow or a gel pillow, both of which had side cutouts, for 5 consecutive nights each, in random order. After night 15, auto-CPAP machine data were downloaded and patients rated their satisfaction with each pillow on a visual analog scale. Results: Twenty-two patients completed the protocol. The pressures administered, residual apnea-hypopnea index, air leaks, and mean duration of CPAP use did not differ among the periods during which each pillow was used. Patients were significantly more satisfied with the gel pillow than with the control pillow and the foam pillow (p = 0.022 and p = 0.004, respectively), their level of satisfaction with the gel pillow correlating significantly with excessive daytime sleepiness (r2 = 0.19; p = 0.0443). Conclusions: Among obstructive sleep apnea patients treated with nasal CPAP, the use of a gel pillow with side cutouts appears to have no impact on treatment effectiveness. Nevertheless, such patients seem to prefer a gel pillow over other types of pillows. PMID:27812636

  19. Spousal involvement and CPAP adherence: a dyadic perspective.

    PubMed

    Ye, Lichuan; Malhotra, Atul; Kayser, Karen; Willis, Danny G; Horowitz, June A; Aloia, Mark S; Weaver, Terri E

    2015-02-01

    Poor adherence to continuous positive airway pressure (CPAP) treatment is associated with substantial health care costs, morbidity and mortality, and has been a leading obstacle in the effective management of obstructive sleep apnea (OSA). Successful interventions to improve CPAP adherence may ultimately include a variety of components. For patients living with spouses (refers to all domestic partners), the spouse will likely be an integral component to any successful intervention. Developing understanding of the role of spouses in adherence to CPAP has been identified to be a critical research need. This review expands the investigation of CPAP adherence to a broader context, from an exclusive focus on individual patients to a dyadic perspective encompassing both patients and their spouses. A conceptual framework based on social support and social control theories is proposed to understand spousal involvement in CPAP adherence. Methodologies for future investigations are discussed, along with implications for developing interventions that engage both patients and their spouses to improve CPAP use.

  20. Otic Barotrauma Resulting from Continuous Positive Airway Pressure: Case Report and Literature Review

    PubMed Central

    McCormick, Justin P.; Hildrew, Douglas M.; Lawlor, Claire M.; Guittard, Jesse A.; Worley, N. Knight

    2016-01-01

    Background: Obstructive sleep apnea (OSA) is a growing problem affecting millions of people in the United States. The prevalence of OSA has risen drastically in the past few decades concurrently with the increasing prevalence of obesity. Subsequently, there has been an ever-increasing rise in the use of continuous positive airway pressure (CPAP) devices. While using CPAP devices may lead to many adverse effects, the majority of these effects are described as relatively benign. Case Report: We describe the detailed clinical course and outcome for a patient with otic barotrauma as a result of excessive self-titration of CPAP therapy in an in-home setting. We also discuss the pathophysiology of otic barotrauma and present a review of current literature on the topic. Conclusion: While the benefits of CPAP are clear, we must take into account the rare but possible effects on ear structure and function. Many studies describe an increase in middle ear pressure with the use of CPAP, but few describe the effects of this increased pressure on the middle ear, such as the otic barotrauma described in this case. Given the increased prevalence of OSA, it is important to understand the risks associated with CPAP therapy. PMID:27303224

  1. Management of severe obstructive sleep apnea using mandibular advancement devices with auto continuous positive airway pressures

    PubMed Central

    Upadhyay, Rashmi; Dubey, Abhishek; Kant, Surya; Singh, Balendra Pratap

    2015-01-01

    The use of continuous positive airway pressures (CPAP) is considered standard treatment of moderate to severe obstructive sleep apnea (OSA). Treatment of the disease poses a great challenge not only for its diagnostic purpose but also for its treatment part. In about 29-83% of the patients, treatment is difficult because of non-compliance resulting due to high pressures, air leaks and other related issues. In such situations, alternative methods of treatment need to be looked for so as to ascertain better management. Mandibular advancement devices along with CPAP may show better treatment outcome in specific situations. PMID:25814802

  2. Controlled trial of continuous positive airway pressure given by face mask for hyaline membrane disease.

    PubMed Central

    Allen, L P; Reynolds, E R; Rivers, R P; Le Souëf, P M; Wimberley, P D

    1977-01-01

    A controlled trial of elective intervention with continuous positive airway pressure (CPAP) was performed on 24 infants with hyaline membrane disease whose arterial oxygen tension (Pao2) fell below 8kPa (60 mmHg) while they were breathing a fractional inspired oxygen concentration (F1O2) greater than 0.60. A face mask was used to apply the CPAP. The progress of the 12 infants who were treated on entry to the trial was compared with that of 12 infants who were treated later. All 12 infants in the early-intervention group and 8 infants in the late-intervention group survived. When CPAP was started, Pao2 increased and the early-treated infants breathed high concentrations of oxygen for a shorter period than the late-treated infants. The 4 infants in the early-intervention group who required mechanical ventilation needed lower mean airway pressures to achieve satisfactory gas exchange than the 7 ventilated infants in the late-intervention group. We conclude that a Pao2 less than 8 kPa while breathing an F1o2 greater than 0.60 is an adequate indication for giving CPAP in hyaline membrane disease, and that early intervention with CPAP allows infants who go on to require mechanical ventilation to be ventilated at lower pressures. PMID:326199

  3. Effectiveness of applying continuous positive airway pressure in a patient with paradoxical vocal fold movement after endotracheal extubation: a case report

    PubMed Central

    Song, Keu La Me; Ko, Dong Chan; Pin, Jung Woo; Ryu, Kyong Ho; Kim, Hyun Soo

    2016-01-01

    Paradoxical vocal fold movement (PVFM) is an uncommon upper airway disorder defined as paradoxical adduction of the vocal folds during inspiration. The etiology and treatment of PVFM are unclear. The physician should manage this condition because of the possibility of near complete airway obstruction in severe case of PVFM. We report a case of successful airway management in a patient with PVFM by applying continuous positive airway pressure (CPAP). In this case, PVFM was detected after removing an endotracheal tube from a 67-year-old male who underwent excision of a laryngeal mass. The patient recovered without complications in 1 day with support by CPAP. PMID:26885309

  4. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series

    PubMed Central

    Ng, Justin R.; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G.; Chai-Coetzer, Ching Li; McEvoy, R. Doug; Antic, Nick

    2016-01-01

    Study Objectives: The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. Methods: We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. Results: The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m2) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. Conclusions: If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Ng JR, Aiyappan V, Mercer J, Catcheside PG, Chai-Coetzer CL, McEvoy RD, Antic N. Choosing an oronasal mask to deliver continuous positive airway pressure may cause more upper airway obstruction or lead to higher continuous positive airway pressure requirements than a nasal

  5. Effect of Acute Intermittent CPAP Depressurization during Sleep in Obese Patients

    PubMed Central

    Jun, Jonathan C.; Unnikrishnan, Dileep; Schneider, Hartmut; Kirkness, Jason; Schwartz, Alan R.; Smith, Philip L.; Polotsky, Vsevolod Y.

    2016-01-01

    Background Obstructive Sleep Apnea (OSA) describes intermittent collapse of the airway during sleep, for which continuous positive airway pressure (CPAP) is often prescribed for treatment. Prior studies suggest that discontinuation of CPAP leads to a gradual, rather than immediate return of baseline severity of OSA. The objective of this study was to determine the extent of OSA recurrence during short intervals of CPAP depressurization during sleep. Methods Nine obese (BMI = 40.4 ± 3.5) subjects with severe OSA (AHI = 88.9 ± 6.8) adherent to CPAP were studied during one night in the sleep laboratory. Nasal CPAP was delivered at therapeutic (11.1 ± 0.6 cm H20) or atmospheric pressure, in alternating fashion for 1-hour periods during the night. We compared sleep architecture and metrics of OSA during CPAP-on and CPAP-off periods. Results 8/9 subjects tolerated CPAP withdrawal. The average AHI during CPAP-on and CPAP-off periods was 3.6 ± 0.6 and 15.8 ± 3.6 respectively (p<0.05). The average 3% ODI during CPAP-on and CPAP-off was 4.7 ± 2 and 20.4 ± 4.7 respectively (p<0.05). CPAP depressurization also induced more awake (p<0.05) and stage N1 (p<0.01) sleep, and less stage REM (p<0.05) with a trend towards decreased stage N3 (p = 0.064). Conclusion Acute intermittent depressurization of CPAP during sleep led to deterioration of sleep architecture but only partial re-emergence of OSA. These observations suggest carryover effects of CPAP. PMID:26731735

  6. Obstructive sleep apnoea in the elderly: role of continuous positive airway pressure treatment.

    PubMed

    Martínez-García, Miguel Ángel; Chiner, Eusebi; Hernández, Luis; Cortes, Jose Pascual; Catalán, Pablo; Ponce, Silvia; Diaz, Jose Ramón; Pastor, Ester; Vigil, Laura; Carmona, Carmen; Montserrat, Josep Maria; Aizpuru, Felipe; Lloberes, Patricia; Mayos, Mercedes; Selma, Maria José; Cifuentes, Jose Fernando; Muñoz, Alvaro

    2015-07-01

    Almost all the information about the effect of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnoea (OSA) comes from clinical trials involving only middle-aged patients. The objective of this study was to assess the effect of CPAP treatment in elderly patients with severe OSA on clinical, quality-of-life and neurocognitive spheres. We performed an open-label, randomised, multicentre clinical trial in a consecutive clinical cohort of 224 elderly (≥70 years old) patients with confirmed severe OSA (apnoea-hypopnea index ≥30) randomised to receive CPAP (n=115) or no CPAP (n=109) for 3 months. A sleep study was performed by either full polysomnography or respiratory polygraphy. CPAP titration was performed by an autoCPAP device. The primary endpoint was quality of life (Quebec Sleep Questionnaire) and secondary endpoints included sleep-related symptoms, presence of anxiety/depression, office-based blood pressure and some neurocognitive tests. The mean±sd age was 75.5±3.9 years. The CPAP group achieved a greater improvement in all quality-of-life domains (p<0.001; effect size: 0.41-0.98), sleep-related symptoms (p<0.001; effect size 0.31-0.91) as well as anxiety (p=0.016; effect size 0.51) and depression (p<0.001; effect size: 0.28) indexes and some neurocognitive tests (digit symbol test (p=0.047; effect size: 0.20) and Trail Making Test A (p=0.029; effect size: 0.44)) in an intention-to-treat analysis. In conclusion, CPAP treatment resulted in an improvement in quality of life, sleep-related symptoms, anxiety and depression indexes and some neurocognitive aspects in elderly people with severe OSA.

  7. The effect of continuous positive airway pressure on metabolic variables in patients with obstructive sleep apnoea.

    PubMed

    Schlatzer, Christian; Schwarz, Esther I; Kohler, Malcolm

    2014-02-01

    Obstructive sleep apnoea (OSA) is increasingly considered as a risk factor for metabolic disturbances, such as diabetes mellitus or dyslipidaemia. Continuous positive airway pressure (CPAP) therapy, the standard treatment for patients with OSA, may improve various metabolic variables, such as insulin sensitivity, glucose metabolism, lipids, fat distribution and adipokines. Several observational and uncontrolled clinical studies claim an improvement of these metabolic variables through the use of CPAP. However, there is only a limited number of clinical randomised controlled trials (RCTs) evaluating the effect of CPAP on metabolic variables. In this review, we summarise and discuss non-randomised studies and RCTs evaluating the effect of CPAP on metabolic variables in patients with OSA. In summary, the currently available body of evidence does not support a clinically important effect of CPAP treatment on any of the investigated metabolic variables. However, some investigators found small, but statistically significant changes in some metabolic variables, thus beneficial effects of CPAP treatment in selected patient cohorts cannot be excluded. To answer this question, more data from RCTs with well-defined study populations are warranted.

  8. Continuous positive airway pressure therapy in non-sleepy patients with obstructive sleep apnea: results of a meta-analysis

    PubMed Central

    Zhang, Dongmei; Luo, Jinmei; Qiao, Yixian

    2016-01-01

    Background Although continuous positive airway pressure (CPAP) has become the first line of therapy for obstructive sleep apnea (OSA), it remains controversial whether non-sleepy patients could benefit from CPAP treatment. Methods We searched the online databases Medline, Embase, the Cochrane library and the Cochrane Central Registry of Controlled Trials to select eligible control trials, including non-sleepy OSA patients and those patients treated by CPAP or either sham CPAP or no CPAP. Results Seven eligible studies (1,541 patients) were included. The pooled estimates of the mean changes after CPAP treatment for the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were −0.51 mmHg (95% CI, −3.39 to 2.38 mmHg; P=0.73) and −0.92 mmHg (95% CI, −1.39 to −0.46 mmHg; P<0.001), respectively. CPAP should not improve subjective sleepiness in the minimally symptomatic OSA patients, as the change in the Epworth sleepiness scale (ESS) was −0.51 (95% CI, −1.68 to 0.67; P=0.397). However, CPAP can effectively reduce AHI or ODI by 15.57 events/h (95% CI, −29.32 to −1.82; P=0.026) compared to controls. However, the risk of cardiovascular events did not significantly decrease [odds ratio (OR), 0.80; 95% CI, 0.50 to 1.26; P=0.332] in the end. Conclusions CPAP treatment can reduce OSA severity in non-sleepy patients and minutely reduce the DBP, but CPAP seems to have no overall beneficial effects on subjective sleepiness, SBP, or cardiovascular risk. PMID:27867549

  9. Mouth leak with nasal continuous positive airway pressure increases nasal airway resistance.

    PubMed

    Richards, G N; Cistulli, P A; Ungar, R G; Berthon-Jones, M; Sullivan, C E

    1996-07-01

    Nasal congestion, dry nose and throat, and sore throat affect approximately 40% of patients using nasal continuous positive airway pressure (CPAP). The mechanisms causing nasal symptoms are unclear, but mouth leaks causing high unidirectional nasal airflow may be important. We conducted a study to investigate the effects of mouth leak and the influence of humidification on nasal resistance in normal subjects. Nasal resistance was measured with posterior rhinomanometry in six normal subjects who deliberately produced a mouth leak for 10 min while using nasal CPAP. Nasal resistance was measured regularly for 20 min after the challenge. A series of tests were performed using air at differing temperatures and humidities. There was no change in nasal resistance when subjects breathed through their noses while on CPAP, but a mouth leak caused a large increase in resistance (at a flow of 0.5 L/s) from a baseline mean of 2.21 cm H2O/L/s to a maximum mean of 7.52 cm H2O/L/s at 1 min after the challenge. Use of a cold passover humidifier caused little change in the response (maximum mean: 8.27 cm H2O/L/s), but a hot water bath humidifier greatly attenuated the magnitude (maximum mean: 4.02 cm H2O/L/s) and duration of the response. Mouth leak with nasal CPAP leads to high unidirectional nasal airflow, which causes a large increase in nasal resistance. This response can be largely prevented by fully humidifying the inspired air.

  10. Effect of Continuous Positive Airway Pressure on Stroke Rehabilitation: A Pilot Randomized Sham-Controlled Trial

    PubMed Central

    Khot, Sandeep P.; Davis, Arielle P.; Crane, Deborah A.; Tanzi, Patricia M.; Li Lue, Denise; Claflin, Edward S.; Becker, Kyra J.; Longstreth, W.T.; Watson, Nathaniel F.; Billings, Martha E.

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) predicts poor functional outcome after stroke and increases the risk for recurrent stroke. Less is known about continuous positive airway pressure (CPAP) treatment on stroke recovery. Methods: In a pilot randomized, double-blind, sham-controlled trial, adult stroke rehabilitation patients were assigned to auto-titrating or sham CPAP without diagnostic testing for OSA. Change in Functional Independence Measure (FIM), a measure of disability, was assessed between rehabilitation admission and discharge. Results: Over 18 months, 40 patients were enrolled and 10 withdrew from the study: 7 from active and 3 from sham CPAP (p > 0.10). For the remaining 30 patients, median duration of CPAP use was 14 days. Average CPAP use was 3.7 h/night, with at least 4 h nightly use among 15 patients. Adherence was not influenced by treatment assignment or stroke severity. In intention-to-treat analyses (n = 40), the median change in FIM favored active CPAP over sham but did not reach statistical significance (34 versus 26, p = 0.25), except for the cognitive component (6 versus 2.5, p = 0.04). The on-treatment analyses (n = 30) yielded similar results (total FIM: 32 versus 26, p = 0.11; cognitive FIM: 6 versus 2, p = 0.06). Conclusions: A sham-controlled CPAP trial among stroke rehabilitation patients was feasible in terms of recruitment, treatment without diagnostic testing and adequate blinding—though was limited by study retention and CPAP adherence. Despite these limitations, a trend towards a benefit of CPAP on recovery was evident. Tolerance and adherence must be improved before the full benefits of CPAP on recovery can be assessed in larger trials. Citation: Khot SP, Davis AP, Crane DA, Tanzi PM, Li Lue D, Claflin ES, Becker KJ, Longstreth WT, Watson NF, Billings ME. Effect of continuous positive airway pressure on stroke rehabilitation: a pilot randomized sham-controlled trial. J Clin Sleep Med 2016;12(7):1019–1026. PMID

  11. Does personality play a role in continuous positive airway pressure compliance?

    PubMed Central

    Maschauer, Emily L.; Fairley, Donna M.

    2017-01-01

    Key points Continuous positive airway pressure (CPAP) adherence is low among individuals with obstructive sleep apnoea. Type D personality and high scores on the depression and hypochondriasis scales on the Minnesota Multiphasic Personality Inventory (MMPI) have been identified as factors contributing to non-compliance with CPAP. Further research into personality type may assist in understanding why some people adhere to CPAP, while others fail. Obstructive sleep apnoea (OSA) is a condition characterised by repetitive, intermittent partial or complete collapse/obstruction of the upper airway during sleep. Continuous positive airway pressure (CPAP) is highly efficacious in treating OSA but its effectiveness is limited due to suboptimal acceptance and adherence rates, with as many as 50% of OSA patients discontinuing CPAP treatment within the first year. Until recently, research has focused on examining mechanistic and demographic factors that could explain nonadherence (e.g. age, sex, race and education level) with limited applicability in a prospective or clinical manner. More recent research has focused on personality factors or types of patients with OSA who comply and do not comply with CPAP adherence in an attempt to enhance the accuracy of predicting treatment compliance. Type D personality has been found to be prevalent in one third of patients with OSA. The presence of Type D personality increases noncompliance and poor treatment outcomes due to negative affectivity, social inhibition, unhealthy lifestyle, and a reluctance to consult and/or follow medical advice. Conversely, individuals who are more likely to adhere to CPAP treatment tend to have a high internal locus of control and high self-efficacy, self-refer for treatment, and have active coping skills. By assessing personality and coping skills, the clinician may gain insight into the likelihood of a patient’s adherence to treatment. If the patient displays potential risk factors for CPAP

  12. Comparison of the Upper Airway Dynamics of Oronasal and Nasal Masks with Positive Airway Pressure Treatment using cine Magnetic Resonance Imaging

    PubMed Central

    Ebben, Matthew R.; Milrad, Sara; Dyke, Jonathan P.; Phillips, C. Douglas; Krieger, Ana C.

    2016-01-01

    Purpose It is known that oronasal masks are not as effective at opening the upper airway compared to nasal only continuous positive airway pressure (CPAP) masks in patients with sleep disordered breathing. However, the physiological mechanism for this difference in efficacy is not known; although, it has been hypothesized to involve the retroglossal and/or retropalatal region of the upper airway. The objective of this study was to investigate differences in retroglossal and retropalatal anterior-posterior space with the use of oronasal vs. nasal CPAP masks using real-time cine Magnetic Resonance Imaging (cMRI). Methods 10-Subjects (8-men, 2-women) with obstructive sleep apnea (OSA) were given cMRI with both nasal and oronasal CPAP masks. Each subject was imaged with each interface at pressures of 5, 10 and 15 cm of H2O, while in the supine position along the sagittal plane. Results The oronasal mask produced significantly less airway opening in the retropalatal region of the upper airway compared to the nasal mask interface. During exhalation, mask style had a significant effect on anterior-posterior distance p=0.016. No differences were found in the retroglossal region between mask styles. Conclusions Our study confirmed previous findings showing differences in treatment efficacy between oronasal and nasal mask styles. We have shown anatomic evidence that the nasal mask is more effective in opening the upper airway compared to the oronasal mask in the retropalatal region. PMID:25924934

  13. Effectiveness of flow inflating device in providing Continuous Positive Airway Pressure for critically ill children in limited-resource settings: A prospective observational study

    PubMed Central

    Anitha, G. Fatima Shirly; Velmurugan, Lakshmi; Sangareddi, Shanthi; Nedunchelian, Krishnamurthy; Selvaraj, Vinoth

    2016-01-01

    Background and Aims: Noninvasive ventilation (NIV) is an emerging popular concept, which includes bi-level positive airway pressure or continuous positive airway pressure (CPAP). In settings with scarce resources for NIV machines, CPAP can be provided through various indigenous means and one such mode is flow inflating device - Jackson-Rees circuit (JR)/Bain circuit. The study analyses the epidemiology, various clinical indications, predictors of CPAP failure, and stresses the usefulness of flow inflating device as an indigenous way of providing CPAP. Methods: A prospective observational study was undertaken in the critical care unit of a Government Tertiary Care Hospital, from November 2013 to September 2014. All children who required CPAP in the age group 1 month to 12 years of both sexes were included in this study. They were started on indigenous CPAP through flow inflating device on clinical grounds based on the pediatric assessment triangle, and the duration and outcome were analyzed. Results: This study population included 214 children. CPAP through flow inflating device was successful in 89.7% of cases, of which bronchiolitis accounted for 98.3%. A prolonged duration of CPAP support of >96 h was required in pneumonia. CPAP failure was noted in 10.3% of cases, the major risk factors being children <1 year and pneumonia with septic shock. Conclusion: We conclude that flow inflating devices - JR/Bain circuit are effective as an indigenous CPAP in limited resource settings. Despite its benefits, CPAP is not a substitute for invasive ventilation, as when the need for intubation arises timely intervention is needed. PMID:27630454

  14. Effect of a heated humidifier during continuous positive airway pressure delivered by a helmet

    PubMed Central

    Chiumello, Davide; Chierichetti, Monica; Tallarini, Federica; Cozzi, Paola; Cressoni, Massimo; Polli, Federico; Colombo, Riccardo; Castelli, Antonio; Gattinoni, Luciano

    2008-01-01

    Introduction The helmet may be an effective interface for the delivery of noninvasive positive pressure ventilation. The high internal gas volume of the helmet can act as a 'mixing chamber', in which the humidity of the patient's expired alveolar gases increases the humidity of the dry medical gases, thus avoiding the need for active humidification. We evaluated the temperature and humidity of respiratory gases inside the helmet, with and without a heated humidifier, during continuous positive airway pressure (CPAP) delivered with a helmet. Methods Nine patients with acute respiratory failure (arterial oxygen tension/fractional inspired oxygen ratio 209 ± 52 mmHg) and 10 healthy individuals were subjected to CPAP. The CPAP was delivered either through a mechanical ventilator or by continuous low (40 l/min) or high flow (80 l/min). Humidity was measured inside the helmet using a capacitive hygrometer. The level of patient comfort was evaluated using a continuous scale. Results In patients with acute respiratory failure, the heated humidifier significantly increased the absolute humidity from 18.4 ± 5.5 mgH2O/l to 34.1 ± 2.8 mgH2O/l during ventilator CPAP, from 11.4 ± 4.8 mgH2O/l to 33.9 ± 1.9 mgH2O/l during continuous low-flow CPAP, and from 6.4 ± 1.8 mgH2O/l to 24.2 ± 5.4 mgH2O/l during continuous high-flow CPAP. Without the heated humidifier, the absolute humidity was significantly higher with ventilator CPAP than with continuous low-flow and high-flow CPAP. The level of comfort was similar for all the three modes of ventilation and with or without the heated humidifier. The findings in healthy individuals were similar to those in the patients with acute respiratory failure. Conclusion The fresh gas flowing through the helmet with continuous flow CPAP systems limited the possibility to increase the humidity. We suggest that a heated humidifier should be employed with continuous flow CPAP systems. PMID:18426561

  15. Effect of nasal continuous positive airway pressure during sleep on 24-hour blood pressure in obstructive sleep apnea.

    PubMed

    Wilcox, I; Grunstein, R R; Hedner, J A; Doyle, J; Collins, F L; Fletcher, P J; Kelly, D T; Sullivan, C E

    1993-09-01

    Ambulatory blood pressure (BP) was measured noninvasively (Oxford Medilog ABP) at 15-minute intervals for 24 hours before and after 8 weeks of treatment with nasal continuous positive airway pressure (nCPAP) in 19 men with obstructive sleep apnea (OSA). We included both normotensive and hypertensive patients, but hypertensives were studied after withdrawal of antihypertensive drugs. Ambulatory BP before and after treatment was compared using patients as their own controls. Treatment with nCPAP was successfully established in 14 of the 19 patients (74%). Blood pressure fell significantly in patients who were successfully treated: 24-hour mean BP (systolic/diastolic) decreased from 141 +/- 18/89 +/- 11 mm Hg to 134 +/- 19/85 +/- 13 mm Hg (p < 0.05). The reduction in 24-hour mean systolic BP occurred during both day and night, but a significant fall in mean diastolic BP was only observed during the day. The mean blood pressure fell in both normotensive and hypertensive patients. Patients who were inadequately treated with nCPAP had no reduction in mean 24-hour BP. Effective treatment of sleep apnea with nCPAP was associated with a significant fall in both systolic and diastolic BP independent of changes in body weight or alcohol consumption, suggesting that sleep apnea was an independent factor contributing to elevated nighttime and daytime BP in these patients.

  16. Nasal pillows as an alternative interface in patients with obstructive sleep apnoea syndrome initiating continuous positive airway pressure therapy.

    PubMed

    Ryan, Silke; Garvey, John F; Swan, Valerie; Behan, Renata; McNicholas, Walter T

    2011-06-01

    Side-effects directly due to the nasal mask are common in patients with obstructive sleep apnoea syndrome (OSAS) commencing continuous positive airway pressure (CPAP). Recently, nasal pillows have been designed to overcome these issues. Limited evidence exists of the benefits and effectiveness of these devices. Twenty-one patients (19 male, 49±10years) with the established diagnosis of OSAS [apnoea/hypopnoea index (AHI): 52±22] and who had a successful CPAP titration were commenced on CPAP therapy (10±2cmH2O), and randomized to 4weeks of a nasal pillow (P) and a standard nasal mask (M) in a crossover design. Outcome measures were objective compliance, AHI, quality of life, Epworth Sleepiness Score (ESS) and CPAP side-effects. There was no difference in compliance (M versus P: 5.1±1.9h versus 5.0±1.7h; P=0.701) and AHI (2.6±2.7 versus 3.0±2.9; P=0.509). Quality of life and ESS improved with CPAP, but there was no difference in the extent of improvement between both devices. Usage of nasal pillows resulted in less reported pressure on the face and more subjects found the nasal pillow the more comfortable device. However, there was no clear overall preference for either device at the end of the study (mask=57%, pillow=43%; P=0.513). The applied CPAP pressure did not correlate with compliance, AHI and ESS. Furthermore, no differences in outcome parameters were noted comparing groups with CPAP pressure <10 and ≥10cm H(2) O. Nasal pillows are equally effective in CPAP therapy, but do not generally lead to improved compliance.

  17. Continuous positive airway pressure for bronchiolitis in a general paediatric ward; a feasibility study

    PubMed Central

    2014-01-01

    Background Continuous positive airway pressure (CPAP) is commonly used to relieve respiratory distress in infants with bronchiolitis, but has mostly been studied in an intensive care setting. Our prime aim was to evaluate the feasibility of CPAP for infants with bronchiolitis in a general paediatric ward, and secondary to assess capillary PCO2 (cPCO2) levels before and during treatment. Methods From May 1st 2008 to April 30th 2012, infants with bronchiolitis at Stavanger University Hospital were treated with CPAP in a general paediatric ward, but could be referred to an intensive care unit (ICU) when needed, according to in-house guidelines. Levels of cPCO2 were prospectively registered before the start of CPAP and at approximately 4, 12, 24 and 48 hours of treatment as long as CPAP was given. We had a continuous updating program for the nurses and physicians caring for the infants with CPAP. The study was population based. Results 672 infants (3.4%) were hospitalized with bronchiolitis. CPAP was initiated in 53 infants (0.3%; 7.9% of infants with bronchiolitis), and was well tolerated in all but three infants. 46 infants were included in the study, the majority of these (n = 33) were treated in the general ward only. These infants had lower cPCO2 before treatment (8.0; 7.7, 8.6)(median; quartiles) than those treated at the ICU (n = 13) (9.3;8.5, 9.9) (p < 0.001). The level of cPCO2 was significantly reduced after 4 h in both groups; 1.1 kPa (paediatric ward) (p < 0.001) and 1.3 kPa (ICU) (p = 0.002). Two infants on the ICU did not respond to CPAP (increasing cPCO2 and severe apnoe) and were given mechanical ventilation, otherwise no side effects were observed in either group treated with CPAP. Conclusion Treatment with CPAP for infants with bronchiolitis may be feasible in a general paediatric ward, providing sufficient staffing and training, and the possibility of referral to an ICU when needed. PMID:24886569

  18. Lung Volume and Continuous Positive Airway Pressure Requirements in Obstructive Sleep Apnea

    PubMed Central

    Heinzer, Raphael C.; Stanchina, Michael L.; Malhotra, Atul; Fogel, Robert B.; Patel, Sanjay R.; Jordan, Amy S.; Schory, Karen; White, David P.

    2005-01-01

    Previous studies have demonstrated that lung volume during wakefulness influences upper airway size and resistance, particularly in patients with sleep apnea. We sought to determine the influence of lung volume on the level of continuous positive airway pressure (CPAP) required to prevent flow limitation during non-REM sleep in subjects with sleep apnea. Seventeen subjects (apnea–hypopnea index, 42.6 ± 6.2 [SEM]) were studied during stable non-REM sleep in a rigid head-out shell equipped with a positive/negative pressure attachment for manipulation of extrathoracic pressure. An epiglottic pressure catheter plus a mask/pneumotachometer were used to assess flow limitation. When lung volume was increased by 1,035 ± 22 ml, the CPAP level could be decreased from 11.9 ± 0.7 to 4.8 ± 0.7 cm H2O (p < 0.001) without flow limitation. The decreased CPAP at the same negative extrathoracic pressure yielded a final lung volume increase of 421 ± 36 ml above the initial value. Conversely, when lung volume was reduced by 732 ± 74 ml (n = 8), the CPAP level had to be increased from 11.9 ± 0.7 to 17.1 ± 1.0 cm H2O (p < 0.001) to prevent flow limitation, with a final lung volume decrease of 567 ± 78 ml. These results demonstrate that relatively small changes in lung volume have an important effect on the upper airway in subjects with sleep apnea during non-REM sleep. PMID:15817803

  19. Long-Term Effects of Continuous Positive Airway Pressure Treatment on Sexuality in Female Patients with Obstructive Sleep Apnea

    PubMed Central

    Petersen, Marian; Kristensen, Ellids; Berg, Søren; Midgren, Bengt

    2013-01-01

    Introduction Results from a previous study showed that sexuality was negatively affected in females with untreated obstructive sleep apnea (OSA). Data are sparse on the long-term effects of nocturnal continuous positive airway pressure (CPAP) treatment on sexual difficulties and sexual distress in female patients with OSA. Aim The aim of the present study was to investigate the effects after 1 year of CPAP treatment on sexual difficulties, sexual distress, and manifest sexual dysfunction in female patients with OSA. The effect of CPAP on life satisfaction was also investigated. Methods Fifty-four therapy-compliant, female patients (age 22–71) received a survey before and after 1 year of nocturnal CPAP treatment. The questions on this survey were drawn from three self-administered questionnaires: two on sexuality and one on life satisfaction. The results were compared with a population sample. The Epworth Sleepiness Scale was used for assessment of daytime sleepiness. Main Outcome Measures The Female Sexual Function Index, Female Sexual Distress Scale, Manifest Female Sexual Dysfunction, four questions from Life Satisfaction 11, and the Epworth Sleepiness Scale were all used to measure outcome. Results In total, 44 patients responded to the survey (81% response rate). The results were a significant, positive change in manifest female sexual dysfunction, but no significant changes in isolated sexual difficulties or sexual distress. Daytime sleepiness significantly decreased after 1 year. The results from the Life Satisfaction 11 questionnaire remained unchanged after 1 year. Conclusions After 1 year of CPAP treatment, female patients with OSA reported reduced manifest sexual dysfunction. However, it cannot be concluded if this result is due to CPAP treatment alone. Furthermore, reduced daytime tiredness was found in the surveyed population. CPAP treatment, per se, does not seem to affect partner relationships. Petersen M, Kristensen E, Berg S, and Midgren B. Long

  20. The effect of short-term withdrawal from continuous positive airway pressure therapy on sympathetic activity and markers of vascular inflammation in subjects with obstructive sleep apnoea.

    PubMed

    Phillips, Craig L; Yang, Qiao; Williams, Andrew; Roth, Michael; Yee, Brendon J; Hedner, Jan A; Berend, Norbert; Grunstein, Ronald R

    2007-06-01

    Obstructive sleep apnoea (OSA) is commonly associated with cardiovascular disease and sympathetic activation. However, it is unclear whether this association is independent of obesity and to what extent treatment with nasal continuous positive airway pressure (CPAP) alleviates the vascular inflammation that underpins cardiovascular disease. We therefore evaluated whether short-term withdrawal from CPAP therapy in subjects with moderate-severe OSA would result in increased levels of sympathetic activity and circulating inflammatory cytokines independent of weight. Vascular inflammatory markers (hsCRP, hsIL-6 and hsTNF-alpha) were assessed in 20 subjects after one and seven nights of withdrawal from CPAP together with the hypoxia-responsive angiogenic marker VEGF and urinary catecholamines. Compared with baseline on CPAP, withdrawal from therapy resulted in an immediate return of OSA with an increase in RDI to 26.7 +/- 5.2 and 39.0 +/- 5.9 events per hour after one and seven nights without CPAP, respectively (both P < 0.0001). This was accompanied by a concomitant rise in daytime urinary noradrenaline (P < 0.0001) after seven nights CPAP withdrawal that was positively associated with the severity of hypoxaemia. In contrast, withdrawal from CPAP therapy was not accompanied by any change in measured cytokines or VEGF (all P > 0.1). In conclusion, 1 week of CPAP withdrawal was associated with a return of OSA and a marked increase in sympathetic activity without a concomitant elevation of vascular inflammatory markers.

  1. Acute effects of nasal continuous positive airway pressure on 24-hour blood pressure and catecholamines in patients with obstructive sleep apnea.

    PubMed

    Minemura, H; Akashiba, T; Yamamoto, H; Akahoshi, T; Kosaka, N; Horie, T

    1998-12-01

    To assess the acute effects of nasal continuous positive airway pressure (CPAP) on the 24-hour blood pressure and the secretion of catecholamines in urine and plasma, we investigated the changes in the 24-hour blood pressure and urinary and plasma concentrations of epinephrine (E) and norepinephrine (NE) in 26 men with obstructive sleep apnea (OSA) with and without nasal CPAP. Nasal CPAP resulted in significant decreases in the daytime diastolic pressure (from 86 +/-16 mmHg to 83+/-12 mmHg), the nighttime diastolic pressure (from 81+/-12 mmHg to 77+/-9 mmHg) and the nighttime systolic pressures (from 125+/-15 mmHg to 120+/-10 mmHg). There was no significant difference between patients with and without CPAP in the daytime or nighttime urinary E level, but patients who received CPAP showed a significant decrease in daytime urinary NE level (from 156+/-112 microg/14h to 119+/-101 microg/14h) and nighttime urinary NE level (from 143+/-91 microg/10h to 112+/-65 microg/10h). The morning plasma level of NE also decreased (from 371+/-181 pg/ml to 273 +/-148 pg/ml) in patients who received nasal CPAP (p<0.02), but the plasma level of E remained unchanged. There were no correlations between PSG parameters and the reductions in blood pressure and the catecholamine levels induced by nasal CPAP. These findings suggest that OSA contributes, at least in part, to the development of systemic hypertension by increasing sympathetic nervous activity.

  2. Sleep apnoea and the hypothalamic-pituitary-adrenal axis in men and women: effects of continuous positive airway pressure.

    PubMed

    Kritikou, Ilia; Basta, Maria; Vgontzas, Alexandros N; Pejovic, Slobodanka; Fernandez-Mendoza, Julio; Liao, Duanping; Bixler, Edward O; Gaines, Jordan; Chrousos, George P

    2016-02-01

    Previous findings on the association of obstructive sleep apnoea (OSA) and the hypothalamic-pituitary-adrenal (HPA) axis are inconsistent, partly due to the confounding effect of obesity and infrequent sampling. Our goal was to examine whether in a relatively nonobese population, OSA is associated with elevated cortisol levels and to assess the effects of a 2-month placebo-controlled continuous positive airway pressure (sham-CPAP) use.72 subjects (35 middle-aged males and post-menopausal females with OSA, and 37 male and female controls) were studied in the sleep laboratory for four nights. 24-h blood sampling was performed every hour on the fourth day and night in the sleep laboratory at baseline, after sham-CPAP and after CPAP treatment.In both apnoeic men and women, OSA was associated with significantly higher 24-h cortisol levels compared with controls, whereas CPAP lowered cortisol levels significantly, close to those of controls.These results suggest that OSA in nonobese men and slightly obese women is associated with HPA axis activation, similar albeit stronger compared with obese individuals with sleep apnoea. Short-term CPAP use decreased cortisol levels significantly compared with baseline, indicating that CPAP may have a protective effect against comorbidities frequently associated with chronic activation of the HPA axis, e.g. hypertension.

  3. Effects of Continuous Positive Airway Pressure on Cognitive and Functional Outcome of Stroke Patients with Obstructive Sleep Apnea: A Randomized Controlled Trial

    PubMed Central

    Aaronson, Justine A.; Hofman, Winni F.; van Bennekom, Coen A.M.; van Bezeij, Tijs; van den Aardweg, Joost G.; Groet, Erny; Kylstra, Wytske A.; Schmand, Ben

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) in stroke patients is associated with worse functional and cognitive status during inpatient rehabilitation. We hypothesized that a four-week period of continuous positive airway pressure (CPAP) treatment would improve cognitive and functional outcomes. Methods: We performed a randomized controlled trial in stroke patients admitted to a neurorehabilitation unit. Patients were assigned to rehabilitation treatment as usual (control group) or to CPAP treatment (CPAP group). Primary outcomes were cognitive status measured by neuropsychological examination, and functional status measured by two neurological scales and a measure of activities of daily living (ADL). Secondary measures included sleepiness, sleep quality, fatigue, and mood. Tests were performed at baseline and after the four-week intervention period. Results: We randomly assigned 20 patients to the CPAP group and 16 patients to the control group. The average CPAP compliance was 2.5 hours per night. Patients in the CPAP group showed significantly greater improvement in the cognitive domains of attention and executive functioning than the control group. CPAP compliance was associated with greater improvement in cognitive functioning. CPAP did not result in measurable improvement on measures of neurological status or ADL, or on any of the secondary measures. Conclusions: CPAP treatment improves cognitive functioning of stroke patients with OSA. Commentary: A commentary on this article appears in this issue on page 467. Citation: Aaronson JA, Hofman WF, van Bennekom CA, van Bezeij T, van den Aardweg JG, Groet E, Kylstra WA, Schmand B. Effects of continuous positive airway pressure on cognitive and functional outcome of stroke patients with obstructive sleep apnea: a randomized controlled trial. J Clin Sleep Med 2016;12(4):533–541. PMID:26888587

  4. Effect of Nasal Obstruction on Continuous Positive Airway Pressure Treatment: Computational Fluid Dynamics Analyses

    PubMed Central

    Wakayama, Tadashi; Suzuki, Masaaki; Tanuma, Tadashi

    2016-01-01

    Objective Nasal obstruction is a common problem in continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea and limits treatment compliance. The purpose of this study is to model the effects of nasal obstruction on airflow parameters under CPAP using computational fluid dynamics (CFD), and to clarify quantitatively the relation between airflow velocity and pressure loss coefficient in subjects with and without nasal obstruction. Methods We conducted an observational cross-sectional study of 16 Japanese adult subjects, of whom 9 had nasal obstruction and 7 did not (control group). Three-dimensional reconstructed models of the nasal cavity and nasopharynx with a CPAP mask fitted to the nostrils were created from each subject’s CT scans. The digital models were meshed with tetrahedral cells and stereolithography formats were created. CPAP airflow simulations were conducted using CFD software. Airflow streamlines and velocity contours in the nasal cavities and nasopharynx were compared between groups. Simulation models were confirmed to agree with actual measurements of nasal flow rate and with pressure and flow rate in the CPAP machine. Results Under 10 cmH2O CPAP, average maximum airflow velocity during inspiration was 17.6 ± 5.6 m/s in the nasal obstruction group but only 11.8 ± 1.4 m/s in the control group. The average pressure drop in the nasopharynx relative to inlet static pressure was 2.44 ± 1.41 cmH2O in the nasal obstruction group but only 1.17 ± 0.29 cmH2O in the control group. The nasal obstruction and control groups were clearly separated by a velocity threshold of 13.5 m/s, and pressure loss coefficient threshold of approximately 10.0. In contrast, there was no significant difference in expiratory pressure in the nasopharynx between the groups. Conclusion This is the first CFD analysis of the effect of nasal obstruction on CPAP treatment. A strong correlation between the inspiratory pressure loss coefficient and maximum airflow

  5. Development and validation of a simple algorithm for initiation of CPAP in neonates with respiratory distress in Malawi

    PubMed Central

    Hundalani, Shilpa G; Richards-Kortum, Rebecca; Oden, Maria; Kawaza, Kondwani; Gest, Alfred; Molyneux, Elizabeth

    2015-01-01

    Background Low-cost bubble continuous positive airway pressure (bCPAP) systems have been shown to improve survival in neonates with respiratory distress, in developing countries including Malawi. District hospitals in Malawi implementing CPAP requested simple and reliable guidelines to enable healthcare workers with basic skills and minimal training to determine when treatment with CPAP is necessary. We developed and validated TRY (T: Tone is good, R: Respiratory Distress and Y=Yes) CPAP, a simple algorithm to identify neonates with respiratory distress who would benefit from CPAP. Objective To validate the TRY CPAP algorithm for neonates with respiratory distress in a low-resource setting. Methods We constructed an algorithm using a combination of vital signs, tone and birth weight to determine the need for CPAP in neonates with respiratory distress. Neonates admitted to the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi, were assessed in a prospective, cross-sectional study. Nurses and paediatricians-in-training assessed neonates to determine whether they required CPAP using the TRY CPAP algorithm. To establish the accuracy of the TRY CPAP algorithm in evaluating the need for CPAP, their assessment was compared with the decision of a neonatologist blinded to the TRY CPAP algorithm findings. Results 325 neonates were evaluated over a 2-month period; 13% were deemed to require CPAP by the neonatologist. The inter-rater reliability with the algorithm was 0.90 for nurses and 0.97 for paediatricians-in-training using the neonatologist's assessment as the reference standard. Conclusions The TRY CPAP algorithm has the potential to be a simple and reliable tool to assist nurses and clinicians in identifying neonates who require treatment with CPAP in low-resource settings. PMID:25877290

  6. High Altitude, Continuous Positive Airway Pressure, and Obstructive Sleep Apnea: Subjective Observations and Objective Data

    PubMed Central

    Malhotra, Atul; Schwartz, Eli

    2013-01-01

    Abstract Ginosar, Yehuda, Atul Malhotra, and Eli Schwartz. High altitude, continuous positive airway pressure, and obstructive sleep apnea: Subjective observations and objective data. High Alt Med Biol 14:186–189, 2013.—We report observations made by one of the authors who ascended to the Thorang La pass (5416 m) in the Nepal Himalaya in October 2010, despite moderate-severe obstructive sleep apnea. We report the first recorded use of nasal CPAP to treat high altitude pulmonary edema (progressively severe dyspnea at rest and severe orthopnea, with tachycardia and tachypnea) that occurred at 4400 meters, when snow and darkness made safe evacuation difficult. We also present objective longitudinal data of the effects of altitude on auto-adjusting CPAP delivered via a portable nasal CPAP device, and on the apnea hypopnea index measured during sleep while using the device. OSA may be a risk factor for the development of high altitude pulmonary edema and we suggest that a nasal CPAP device located in high altitude trekking stations may provide an additional or alternative treatment option for managing high altitude pulmonary edema until evacuation is possible. PMID:23795742

  7. Very Preterm Infants Failing CPAP Show Signs of Fatigue Immediately after Birth

    PubMed Central

    Siew, Melissa L.; van Vonderen, Jeroen J.; Hooper, Stuart B.; te Pas, Arjan B.

    2015-01-01

    Objective To investigate the differences in breathing pattern and effort in infants at birth who failed or succeeded on continuous positive airway pressure (CPAP) during the first 48 hours after birth. Methods Respiratory function recordings of 32 preterm infants were reviewed of which 15 infants with a gestational age of 28.6 (0.7) weeks failed CPAP and 17 infants with a GA of 30.1 (0.4) weeks did not fail CPAP. Frequency, duration and tidal volumes (VT) of expiratory holds (EHs), peak inspiratory flows, CPAP-level and FiO2-levels were analysed. Results EH incidence increased <6 minutes after birth and remained stable thereafter. EH peak inspiratory flows and VT were similar between CPAP-fail and CPAP-success infants. At 9-12 minutes, CPAP-fail infants more frequently used smaller VTs, 0-9 ml/kg and required higher peak inspiratory flows. However, CPAP-success infants often used large VTs (>9 ml/kg) with higher peak inspiratory flows than CPAP-fail infants (71.8 ± 15.8 vs. 15.5 ± 5.2 ml/kg.s, p <0.05). CPAP-fail infants required higher FiO2 (0.31 ± 0.03 vs. 0.21 ± 0.01), higher CPAP pressures (6.62 ± 0.3 vs. 5.67 ± 0.26 cmH2O) and more positive pressure-delivered breaths (45 ± 12 vs. 19 ± 9%) (p <0.05) Conclusion At 9-12 minutes after birth, CPAP-fail infants more commonly used lower VTs and required higher peak inspiratory flow rates while receiving greater respiratory support. VT was less variable and larger VT was infrequently used reflecting early signs of fatigue. PMID:26052947

  8. A Systematic Review of CPAP Adherence Across Age Groups: Clinical and Empiric Insights for Developing CPAP Adherence Interventions

    PubMed Central

    Sawyer, A.M.; Gooneratne, N.; Marcus, C.L.; Ofer, D.; Richards, K.C.; Weaver, T.E.

    2011-01-01

    Continuous positive airway pressure (CPAP) is a highly efficacious treatment for obstructive sleep apnea (OSA) but adherence to the treatment limits its overall effectiveness across all age groups of patients. Factors that influence adherence to CPAP include disease and patient characteristics, treatment titration procedures, technological device factors and side effects, and psychological and social factors. These influential factors have guided the development of interventions to promote CPAP adherence. Various intervention strategies have been described and include educational, technological, psychosocial, pharmacological, and multi-dimensional approaches. Though evidence to date has led to innovative strategies that address adherence in CPAP-treated children, adults, and older adults, significant opportunities exist to develop and test interventions that are clinically applicable, specific to subgroups of patients likely to demonstrate poor adherence, and address the multifactorial nature of CPAP adherence. The translation of CPAP adherence promotion interventions to clinical practice is imperative to improve health and functional outcomes in all persons with CPAP-treated OSA. PMID:21652236

  9. A systematic review of CPAP adherence across age groups: clinical and empiric insights for developing CPAP adherence interventions.

    PubMed

    Sawyer, Amy M; Gooneratne, Nalaka S; Marcus, Carole L; Ofer, Dafna; Richards, Kathy C; Weaver, Terri E

    2011-12-01

    Continuous positive airway pressure (CPAP) is a highly efficacious treatment for obstructive sleep apnea (OSA) but adherence to the treatment limits its overall effectiveness across all age groups of patients. Factors that influence adherence to CPAP include disease and patient characteristics, treatment titration procedures, technological device factors and side effects, and psychological and social factors. These influential factors have guided the development of interventions to promote CPAP adherence. Various intervention strategies have been described and include educational, technological, psychosocial, pharmacological, and multi-dimensional approaches. Though evidence to date has led to innovative strategies that address adherence in CPAP-treated children, adults, and older adults, significant opportunities exist to develop and test interventions that are clinically applicable, specific to sub-groups of patients likely to demonstrate poor adherence, and address the multi-factorial nature of CPAP adherence. The translation of CPAP adherence promotion interventions to clinical practice is imperative to improve health and functional outcomes in all persons with CPAP-treated OSA.

  10. Mandibular Advancement Device as a Comparable Treatment to Nasal Continuous Positive Airway Pressure for Positional Obstructive Sleep Apnea

    PubMed Central

    Takaesu, Yoshikazu; Tsuiki, Satoru; Kobayashi, Mina; Komada, Yoko; Nakayama, Hideaki; Inoue, Yuichi

    2016-01-01

    Study Objectives: Positional obstructive sleep apnea (P-OSA) is a clinically common phenotype of OSA, which can be treated effectively with mandibular advancement devices (MADs). We hypothesized that the efficacy of an MAD is comparable to that of nasal continuous positive airway pressure (nCPAP) in P-OSA patients. Methods: Among patients diagnosed with OSA at a single sleep center from January 2008 to May 2014, male subjects with moderate OSA were recruited and stringently categorized as having P-OSA when the ratio of their lateral apnea-hypopnea index (AHI) to supine AHI was ≤ 0.5, their lateral sleep time was > 60 minutes, and their lateral REM sleep time was longer than 10 minutes. Treatment efficacy was compared between P-OSA subjects with an MAD (n = 34) and those with nCPAP (n = 34) after matching for age, body-mass index, and baseline AHI. Results: There were no significant differences in baseline AHI (MAD: nCPAP = 20.6 ± 3.9/h: 21.3 ± 1.7/h, p = 0.35) or in follow-up AHI (MAD: nCPAP = 4.7 ± 3.5/h: 3.4 ± 3.7/h, p = 0.12) between the 2 treatment groups, and hence MADs lowered the AHI to the same extent as nCPAP. Conclusions: These findings suggest that an MAD is as efficacious as nCPAP for P-OSA patients. MAD treatment for this specific phenotype may be a promising patient-tailored and first-line approach to OSA. Commentary: A commentary on this article appears in this issue on page 1079. Citation: Takaesu Y, Tsuiki S, Kobayashi M, Komada Y, Nakayama H, Inoue Y. Mandibular advancement device as a comparable treatment to nasal continuous positive airway pressure for positional obstructive sleep apnea. J Clin Sleep Med 2016;12(8):1113–1119. PMID:27250814

  11. In patients with minimally symptomatic OSA can baseline characteristics and early patterns of CPAP usage predict those who are likely to be longer-term users of CPAP

    PubMed Central

    Bratton, Daniel J.; Craig, Sonya E.; Kohler, Malcolm; Stradling, John R.

    2016-01-01

    Background Long-term continuous positive airway pressure (CPAP) usage varies between individuals. It would be of value to be able to identify those who are likely to benefit from CPAP (and use it long term), versus those who would not, and might therefore benefit from additional help early on. First, we explored whether baseline characteristics predicted CPAP usage in minimally symptomatic obstructive sleep apnoea (OSA) patients, a group who would be expected to have low usage. Second, we explored if early CPAP usage was predictive of longer-term usage, as has been shown in more symptomatic OSA patients. Methods The MOSAIC trial was a multi-centre randomised controlled trial where minimally symptomatic OSA patients were randomised to CPAP, or standard care, for 6 months. Here we have studied only those patients randomised to CPAP treatment. Baseline characteristics including symptoms, questionnaires [including the Epworth sleepiness score (ESS)] and sleep study parameters were recorded. CPAP usage was recorded at 2–4 weeks after initiation and after 6 months. The correlation and association between baseline characteristics and 6 months CPAP usage was assessed, as was the correlation between 2 and 4 weeks CPAP usage and 6 months CPAP usage. Results One hundred and ninety-five patients randomised to CPAP therapy had median [interquartile range (IQR)] CPAP usage of 2:49 (0:44, 5:13) h:min/night (h/n) at the 2–4 weeks visit, and 2:17 (0:08, 4:54) h/n at the 6 months follow-up visit. Only male gender was associated with increased long-term CPAP use (male usage 2:56 h/n, female 1:57 h/n; P=0.02). There was a moderate correlation between the usage of CPAP at 2–4 weeks and 6 months, with about 50% of the variability in long-term use being predicted by the short-term use. Conclusions In patients with minimally symptomatic OSA, our study has shown that male gender (and not OSA severity or symptom burden) is associated with increased long-term use of CPAP at 6 months

  12. Effect of continuous positive airway pressure on arterial stiffness in patients with obstructive sleep apnea and hypertension: a meta-analysis.

    PubMed

    Lin, Xin; Chen, Gongping; Qi, Jiachao; Chen, Xiaofang; Zhao, Jiangming; Lin, Qichang

    2016-12-01

    Arterial stiffness has been recognized as a predictor of cardiovascular and all-cause mortality in hypertensive patients. However, the impact of continuous positive airway pressure (CPAP) on arterial stiffness in patients with OSA and hypertension remains inconclusive. We performed a meta-analysis to determine whether effective CPAP therapy could decrease arterial stiffness. Two reviewers independently searched PubMed, Embase, Web of Science and Cochrane Library prior to March 5, 2015. Information on characteristics of subjects, study design and pre- and post-CPAP treatment of arterial stiffness was extracted for analysis. Standardized mean difference (SMD) was used to analyze the summary estimates for CPAP therapy. Three articles with 186 patients were included in this meta-analysis, including two observational studies and one randomized controlled study. The meta-analysis showed that CPAP was associated with a statistically significant decrease in arterial stiffness in patients with OSA and hypertension (SMD = -0.65, 95 % confidence interval (CI) = -1.14 to -0.16, z = 2.60, p = 0.009). Our meta-analysis suggested that CPAP among OSA and hypertensive patients was significantly associated with a decrease in arterial stiffness. Further prospective large-scale multicenter RCTs are needed to explore the precise impact of CPAP therapy on arterial stiffness in patients with OSA and hypertension.

  13. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea.

    PubMed

    Andrade, Rafaela Garcia Santos de; Piccin, Vivien Schmeling; Nascimento, Juliana Araújo; Viana, Fernanda Madeiro Leite; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2014-01-01

    Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.

  14. Airway dynamics in COPD patients by within-breath impedance tracking: effects of continuous positive airway pressure.

    PubMed

    Lorx, András; Czövek, Dorottya; Gingl, Zoltán; Makan, Gergely; Radics, Bence; Bartusek, Dóra; Szigeti, Szabolcs; Gál, János; Losonczy, György; Sly, Peter D; Hantos, Zoltán

    2017-02-01

    Tracking of the within-breath changes of respiratory mechanics using the forced oscillation technique may provide outcomes that characterise the dynamic behaviour of the airways during normal breathing.We measured respiratory resistance (Rrs) and reactance (Xrs) at 8 Hz in 55 chronic obstructive pulmonary disease (COPD) patients and 20 healthy controls, and evaluated Rrs and Xrs as functions of gas flow (V') and volume (V) during normal breathing cycles. In 12 COPD patients, additional measurements were made at continuous positive airway pressure (CPAP) levels of 4, 8, 14 and 20 hPa.The Rrs and Xrsversus V' and V relationships displayed a variety of loop patterns, allowing characterisation of physiological and pathological processes. The main outcomes emerging from the within-breath analysis were the Xrsversus V loop area (AXV) quantifying expiratory flow limitation, and the tidal change in Xrs during inspiration (ΔXI) reflecting alteration in lung inhomogeneity in COPD. With increasing CPAP, AXV and ΔXI approached the normal ranges, although with a large variability between individuals, whereas mean Rrs remained unchanged.Within-breath tracking of Rrs and Xrs allows an improved assessment of expiratory flow limitation and functional inhomogeneity in COPD; thereby it may help identify the physiological phenotypes of COPD and determine the optimal level of respiratory support.

  15. Effect of continuous positive airway pressure therapy on hypothalamic-pituitary-adrenal axis function and 24-h blood pressure profile in obese men with obstructive sleep apnea syndrome.

    PubMed

    Carneiro, Gláucia; Togeiro, Sônia Maria; Hayashi, Lílian F; Ribeiro-Filho, Fernando Flexa; Ribeiro, Artur Beltrame; Tufik, Sérgio; Zanella, Maria Teresa

    2008-08-01

    Obstructive sleep apnea syndrome (OSAS) increases the risk of cardiovascular events. Sympathetic nervous system and hypothalamic-pituitary-adrenal (HPA) axis activation may be the mechanism of this relationship. The aim of this study was to evaluate HPA axis and ambulatory blood pressure monitoring in obese men with and without OSAS and to determine whether nasal continuous positive airway pressure therapy (nCPAP) influenced responses. Twenty-four-hour ambulatory blood pressure monitoring and overnight cortisol suppression test with 0.25 mg of dexamethasone were performed in 16 obese men with OSAS and 13 obese men controls. Nine men with severe apnea were reevaluated 3 mo after nCPAP therapy. Body mass index and blood pressure of OSAS patients and obese controls were similar. In OSAS patients, the percentage of fall in systolic blood pressure at night (P = 0.027) and salivary cortisol suppression postdexamethasone (P = 0.038) were lower, whereas heart rate (P = 0.022) was higher compared with obese controls. After nCPAP therapy, patients showed a reduction in heart rate (P = 0.036) and a greater cortisol suppression after dexamethasone (P = 0.001). No difference in arterial blood pressure (P = 0.183) was observed after 3 mo of nCPAP therapy. Improvement in cortisol suppression was positively correlated with an improvement in apnea-hypopnea index during nCPAP therapy (r = 0.799, P = 0.010). In conclusion, men with OSAS present increased postdexamethasone cortisol levels and heart rate, which were recovered by nCPAP.

  16. Predictors of Long-Term Adherence to Continuous Positive Airway Pressure Therapy in Patients with Obstructive Sleep Apnea and Cardiovascular Disease in the SAVE Study

    PubMed Central

    Chai-Coetzer, Ching Li; Luo, Yuan-Ming; Antic, Nick A.; Zhang, Xi-Long; Chen, Bao-Yuan; He, Quan-Ying; Heeley, Emma; Huang, Shao-Guang; Anderson, Craig; Zhong, Nan-Shan; McEvoy, R. Doug

    2013-01-01

    Study Objectives: To determine the clinical variables that best predict long- term continuous positive airway pressure (CPAP) adherence among patients with cardiovascular disease who have obstructive sleep apnea (OSA). Design: 12-mo prospective within-trial observational study. Setting: Centers in China, Australia, and New Zealand participating in the Sleep Apnea cardioVascular Endpoints (SAVE) study. Patients: There were 275 patients age 45-70 y with cardiovascular disease (i.e., previously documented transient ischemic attack, stroke, or coronary artery disease) and OSA (4% oxygen desaturation index (ODI) > 12) who were randomized into the CPAP arm of the SAVE trial prior to July 1, 2010. Methods: Age, sex, country of residence, type of cardiovascular disease, baseline ODI, severity of sleepiness, and Hospital Anxiety and Depression Scale (HADS) scores plus CPAP side effects and adherence at 1 mo were entered in univariate analyses in an attempt to identify factors predictive of CPAP adherence at 12 mo. Variables with P < 0.2 were then included in a multivariate analysis using a linear mixed model with sites as a random effect and 12-mo CPAP use as the dependent outcome variable. Measurements and Results: CPAP adherence at 1, 6, and 12 mo was (mean ± standard deviation) 4.4 ± 2.0, 3.8 ± 2.3, and 3.3 ± 2.4 h/night, respectively. CPAP use at 1 mo (effect estimate ± standard error, 0.65 ± 0.07 per h increase, P < 0.001) and side effects at 1 mo (-0.24 ± 0.092 per additional side effect, P = 0.009) were the only independent predictors of 12- mo CPAP adherence. Conclusion: Continuous positive airway pressure use in patients with coexisting cardiovascular disease and moderate to severe obstructive sleep apnea decreases significantly over 12 months. This decline can be predicted by early patient experiences with continuous positive airway pressure (i.e., adherence and side effects at 1 month), raising the possibility that intensive early interventions could

  17. Effects of 12 Months Continuous Positive Airway Pressure on Sympathetic Activity Related Brainstem Function and Structure in Obstructive Sleep Apnea

    PubMed Central

    Henderson, Luke A.; Fatouleh, Rania H.; Lundblad, Linda C.; McKenzie, David K.; Macefield, Vaughan G.

    2016-01-01

    Muscle sympathetic nerve activity (MSNA) is greatly elevated in patients with obstructive sleep apnea (OSA) during normoxic daytime wakefulness. Increased MSNA is a precursor to hypertension and elevated cardiovascular morbidity and mortality. However, the mechanisms underlying the high MSNA in OSA are not well understood. In this study we used concurrent microneurography and magnetic resonance imaging to explore MSNA-related brainstem activity changes and anatomical changes in 15 control and 15 OSA subjects before and after 6 and 12 months of continuous positive airway pressure (CPAP) treatment. We found that following 6 and 12 months of CPAP treatment, resting MSNA levels were significantly reduced in individuals with OSA. Furthermore, this MSNA reduction was associated with restoration of MSNA-related brainstem activity and structural changes in the medullary raphe, rostral ventrolateral medulla, dorsolateral pons, and ventral midbrain. This restoration occurred after 6 months of CPAP treatment and was maintained following 12 months CPAP. These findings show that continual CPAP treatment is an effective long-term treatment for elevated MSNA likely due to its effects on restoring brainstem structure and function. PMID:27013952

  18. Default network response to a working memory challenge after withdrawal of continuous positive airway pressure treatment for obstructive sleep apnea.

    PubMed

    Sweet, Lawrence H; Jerskey, Beth A; Aloia, Mark S

    2010-06-01

    Lower working memory performance and altered brain activity have been reported in studies of obstructive sleep apnea (OSA) patients. However, little is known about the effect of treatment of OSA on brain function, particularly effects on default network processing. We previously reported increased brain response to a working memory challenge in active regions and decreased response in relatively deactivated a priori regions of interest (ROIs) following withdrawal of continuous positive airway pressure (CPAP) treatment. This follow-up analysis was conducted to examine the effects of CPAP withdrawal on default network processing using empirically defined ROIs analyses (i.e., in ROIs exhibiting significant deactivation in the sample). Ten OSA patients performed a 2-Back working memory task during functional magnetic resonance imaging in two separate conditions, following regular CPAP use, and after two nights of CPAP withdrawal. Eleven clusters of significant 2-Back-related deactivation consistent with the default network were identified and further examined for CPAP withdrawal effects. Significant further deactivation relative to the treatment adherent baseline was observed in the majority of these ROIs during the withdrawal condition. The magnitude of deactivation during withdrawal was significantly associated with better working memory performance in the posterior cingulate and right postcentral gyrus, and greater sleepiness in the left and right medial frontal gyrus. Results suggest that default network functions are further suspended as a result of a shifting of attention towards a more difficult active task in the context of lowered attentional capacity related to sleepiness.

  19. A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports

    PubMed Central

    Brown, Jocelyn; Machen, Heather; Kawaza, Kondwani; Mwanza, Zondiwe; Iniguez, Suzanne; Lang, Hans; Gest, Alfred; Kennedy, Neil; Miros, Robert; Richards-Kortum, Rebecca; Molyneux, Elizabeth; Oden, Maria

    2013-01-01

    Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design—consumer-grade pumps, medical tubing, and regulators—it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device. PMID:23372661

  20. Overnight Motor Skill Learning Outcomes in Obstructive Sleep Apnea: Effect of Continuous Positive Airway Pressure

    PubMed Central

    Landry, Shane; O'Driscoll, Denise M.; Hamilton, Garun S.; Conduit, Russell

    2016-01-01

    Study Objective: To determine the effectiveness of continuous positive airway pressure (CPAP) therapy in alleviating known impairments in the overnight consolidation of motor skill learning in patients with obstructive sleep apnea (OSA). Methods: Twenty-five patients with untreated moderate-severe OSA, 13 first-night CPAP users, 17 compliant CPAP users, and 14 healthy control patients were trained on a motor sequence learning task (Sequential Finger Tapping Task, SFTT) and were subsequently tested prior to and after polysomnographic recorded sleep. Measures of subjective sleepiness (Karolinska Sleepiness Scale) and sustained attention (Psychomotor Vigilance Task) were also completed before and after sleep. Results: Typical analyses of overnight improvement on the SFTT show significantly greater overnight gains in motor task speed in controls (+11.6 ± 4.7%, p = 0.007) and compliant CPAP users (+8.9 ± 4.3%, p = 0.008) compared to patients with OSA (−4.86 ± 4.5%). Additional analyses suggest that these improvements in motor performance occurred prior to the sleep episode, as all groups significantly improved (15% to 22%) over a 10-min presleep rest period. Thereafter, performance in all groups significantly deteriorated over sleep (6% to 16%) with trends toward patients with OSA showing greater losses in performance compared to control patients and compliant CPAP users. No between-group differences in subjective sleepiness and sustained attention were found presleep and postsleep. Conclusions: The current data suggest impairments in overnight motor learning in patients with OSA may be a combination of deficient stabilization of memory over a sleep episode as well as increased vulnerability to time on task fatigue effects. Compliant CPAP usage possibly offsets both of these impediments to learning outcomes by improving both sleep quality and subsequent daytime function. Citation: Landry S, O'Driscoll DM, Hamilton GS, Conduit R. Overnight motor skill learning

  1. Expiratory Positive Airway Pressure for Sleep Apnea after Stroke: A Randomized, Crossover Trial

    PubMed Central

    Wheeler, Natalie C.; Wing, Jeffrey J.; O'Brien, Louise M.; Hughes, Rebecca; Jacobs, Teresa; Claflin, Edward; Chervin, Ronald D.; Brown, Devin L.

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is common after stroke and predicts poor outcomes. Continuous positive airway pressure (CPAP) treats OSA but is generally poorly tolerated by stroke patients. We assessed whether nasal expiratory positive airway pressure (EPAP), an alternative to CPAP, may be an effective option after acute stroke. Methods: We conducted a randomized, controlled, two-period crossover study in which each acute ischemic stroke patient received 1 night of EPAP and 1 night without EPAP while OSA was monitored with a validated device, the Watch-PAT 200. Linear repeated- measures analyses were conducted. Sample size calculations indicated that 18 subjects would be required to detect a 10-point or larger average reduction in the apnea-hypopnea index (AHI, the primary outcome), with use of EPAP, with power ≥ 80% and α = 0.05. Results: Among the 19 subjects who completed the protocol, nasal EPAP treatment was associated with a nonsignificant absolute difference in AHI of −5.73 events/h in the primary analysis (p = 0.183, 95% confidence interval −14.4, 2.97) and a nonsignificant absolute difference in AHI of −5.43 events/h in the subgroup of patients who used nasal EPAP for ≥ 3 h (p = 0.314, 95% confidence interval −16.6, 5.76). Conclusions: This study suggests that EPAP is not an effective alternative to CPAP in acute stroke patients with OSA. Further work is needed to identify other more effective alternatives. Clinical Trial Registration: ClinicalTrials.gov, ID: NCT01703663 Citation: Wheeler NC, Wing JJ, O'Brien LM, Hughes R, Jacobs T, Claflin E, Chervin RD, Brown DL. Expiratory positive airway pressure for sleep apnea after stroke: a randomized, crossover trial. J Clin Sleep Med 2016;12(9):1233–1238. PMID:27306393

  2. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    SciTech Connect

    Goldstein, Jeffrey D.; Lawrence, Yaacov R.; Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader; Segel, Michael J.; Peled, Nir; Symon, Zvi

    2015-10-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.

  3. CPAP Tips

    MedlinePlus Videos and Cool Tools

    ... 46. apapuser 242,704 views 8:46 ABC Good Morning America Health - Sleep Apnea Solutions by 1800CPAP. ... 23 Choosing a CPAP BiPAP xPAP Mask: Some Good Masks To Start With - Duration: 11:34. TheLankyLefty27 ...

  4. Continuous Positive Airway Pressure Improves Sleep and Daytime Sleepiness in Patients with Parkinson Disease and Sleep Apnea

    PubMed Central

    Neikrug, Ariel B.; Liu, Lianqi; Avanzino, Julie A.; Maglione, Jeanne E.; Natarajan, Loki; Bradley, Lenette; Maugeri, Alex; Corey-Bloom, Jody; Palmer, Barton W.; Loredo, Jose S.; Ancoli-Israel, Sonia

    2014-01-01

    Study Objectives: Obstructive sleep apnea (OSA), common in Parkinson disease (PD), contributes to sleep disturbances and daytime sleepiness. We assessed the effect of continuous positive airway pressure (CPAP) on OSA, sleep, and daytime sleepiness in patients with PD. Design: This was a randomized placebo-controlled, crossover design. Patients with PD and OSA were randomized into 6 w of therapeutic treatment or 3 w of placebo followed by 3 w of therapeutic treatment. Patients were evaluated by polysomnography (PSG) and multiple sleep latency test (MSLT) pretreatment (baseline), after 3 w, and after 6 w of CPAP treatment. Analyses included mixed models, paired analysis, and within-group analyses comparing 3 w to 6 w of treatment. Setting: Sleep laboratory. Participants: Thirty-eight patients with PD (mean age = 67.2 ± 9.2 y; 12 females). Intervention: Continuous positive airway pressure. Measurements: PSG outcome measures: sleep efficiency, %sleep stages (N1, N2, N3, R), arousal index, apnea-hypopnea index (AHI), and % time oxygen saturation < 90% (%time SaO2 < 90%). MSLT outcome measures: mean sleep-onset latency (MSL). Results: There were significant group-by-time interactions for AHI (P < 0.001), % time SaO2 < 90% (P = 0.02), %N2 (P = 0.015) and %N3 (P = 0.014). Subjects receiving therapeutic CPAP showed significant decrease in AHI, %time SaO2 < 90%, %N2, and significant increase in %N3 indicating effectiveness of CPAP in the treatment of OSA, improvement in nighttime oxygenation, and in deepening sleep. The paired sample analyses revealed that 3 w of therapeutic treatment resulted in significant decreases in arousal index (t = 3.4, P = 0.002). All improvements after 3 w were maintained at 6 w. Finally, 3 w of therapeutic CPAP also resulted in overall decreases in daytime sleepiness (P = 0.011). Conclusions: Therapeutic continuous positive airway pressure versus placebo was effective in reducing apnea events, improving oxygen saturation, and deepening sleep in

  5. New developments in the use of positive airway pressure for obstructive sleep apnea

    PubMed Central

    Boeder, Schafer; Malhotra, Atul; Patel, Sanjay R.

    2015-01-01

    Obstructive sleep apnea (OSA) is a disorder which afflicts a large number of individuals around the world. OSA causes sleepiness and is a major cardiovascular risk factor. Since its inception in the early 1980’s, continuous positive airway pressure (CPAP) has emerged as the major treatment of OSA, and it has been shown to improve sleepiness, hypertension, and a number of cardiovascular indices. Despite its successes, adherence with treatment remains a major limitation. Herein we will review the evidence behind the use of positive airway pressure (PAP) therapy, its various modes, and the methods employed to improve adherence. We will also discuss the future of PAP therapy in OSA and personalization of care. PMID:26380760

  6. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing.

    PubMed

    Aerts, J G; van den Berg, B; Bogaard, J M

    1997-10-01

    The effects of continuous positive airway pressure (CPAP) provided by the Siemens Servo 900C ventilator were compared with a continuous flow system (CF-CPAP) in patients weaning from the ventilator. Thirteen patients were studied using both systems at a CPAP level of 0.5 kPa. Additional work of breathing (Wapp) and derived variables were determined in relation to the minute volumes of the patients. The Wapp imposed by the ventilator exceeded the Wapp of CF-CPAP in all patients. The difference in Wapp between ventilator- and CF-CPAP was greater at higher ventilatory needs. The increments in Wapp imposed by the ventilator were positively correlated with the actual end-expiratory pressures (EEP). The EEP increasingly exceeded the preset CPAP level of the ventilator at higher minute volumes. An inspiratory threshold due to a gradient between EEP and preset CPAP greatly increased the Wapp imposed by the ventilator. As this threshold was attributed to the resistance of the PEEP device of the ventilator, it indicates that the additional work related to the expiratory value should be taken into account when the Siemens Servo 900C ventilator is used for weaning purposes.

  7. The effect of modafinil following acute CPAP withdrawal: a preliminary study.

    PubMed

    Williams, Shaun C; Rogers, Naomi L; Marshall, Nathaniel S; Leung, Stefanie; Starmer, Graham A; Grunstein, Ronald R

    2008-11-01

    Daytime symptoms resulting from obstructive sleep apnea (OSA) include impaired neurobehavioural performance and increased sleepiness. Continuous positive airway pressure (CPAP) reduces these symptoms. However, even compliant users may temporarily withdraw from CPAP treatment resulting in an immediate return of OSA. It has been hypothesised that these treatment "holidays" may be associated with neurobehavioural decline. Acute administration of a wakefulness promoter during such treatment "holidays" may help maintain neurobehavioural functioning. We examined the effects of 200 mg modafinil on neurobehavioural performance in a placebo-controlled crossover trial including N = 12 OSA patients acutely removed from CPAP. Sleep-wake activity was assessed for four consecutive days on CPAP and one night off CPAP using actigraphy. During the night off, CPAP patients wore a single channel nasal airflow diagnostic device. On the morning after CPAP withdrawal, patients reported to the laboratory and were administered either modafinil (200 mg) or placebo. At 2 h post-administration, patients completed a single simulated drive of approximately 30 min with simultaneous administration of a divided attention task (STISIMtrade mark), critical flicker fusion (CFF) test and subjective sleepiness scales. After a 14-day washout, participants repeated the protocol. CPAP withdrawal was associated with a worsening of sleep efficiency and the movement and fragmentation index (MFI), compared to the on-CPAP nights (all p < or = 0.02). Modafinil did not result in a superior driving simulator performance or CFF responses the morning after CPAP withdrawal but did result in better subjective sleepiness (both p < or = 0.04) compared to placebo. These data do not support the use of modafinil for the maintenance of daytime functioning in patients with OSA who are acutely withdrawn from CPAP.

  8. Cues to Starting CPAP in Obstructive Sleep Apnea: Development and Validation of the Cues to CPAP Use Questionnaire

    PubMed Central

    Olsen, Sara; Smith, Simon; Oei, Tian P.S.; Douglas, James

    2010-01-01

    Background: The reasons that a patient has to start treatment, their “Cues to Action,” are important for determining subsequent health behaviors. Cues to action are an explicit component of the Health Belief Model of continuous positive airway pressure (CPAP) acceptance. At present, there is no scale available to measure this construct for individuals with obstructive sleep apnea (OSA). This paper aims to develop, validate, and describe responding patterns within a sample of patients with OSA to the Cues to CPAP Use Questionnaire (CCUQ). Method: Participants were 63 adult patients diagnosed with OSA who had never tried CPAP when initially recruited. The CCUQ was completed at 1 month after being prescribed CPAP. Results: Exploratory factor analysis (EFA) showed a 3-factor structure of the 9-item CCUQ, with “Health Cues,” “Partner Cues,” and “Health Professional Cues” subscales accounting for 59.91% of the total variance. The CCUQ demonstrated modest internal consistency and split-half reliability. The questionnaire is brief and user friendly, with readability at a seventh-grade level. The most frequently endorsed cues for starting CPAP were Health Professional Cues (prompting by the sleep physician) and Health Cues such as tiredness and concern about health outcomes. Conclusions: This study validates a measure of an important motivational component of the Health Belief Model. Health Professional Cues and internal Health Cues were reported to be the most important prompts to commence CPAP by this patient sample. Citation: Olsen S; Smith S; Oei TPS; Douglas J. Cues to starting CPAP in obstructive sleep apnea: development and validation of the cues to CPAP use questionnaire. J Clin Sleep Med 2010;6(3):229-237. PMID:20572415

  9. Significant improvement of olfactory performance in sleep apnea patients after three months of nasal CPAP therapy – Observational study and randomized trial

    PubMed Central

    Boerner, Bettina; Tini, Gabrielo M.; Fachinger, Patrick; Graber, Sereina M.; Irani, Sarosh

    2017-01-01

    Objectives The olfactory function highly impacts quality of life (QoL). Continuous positive airway pressure is an effective treatment for obstructive sleep apnea (OSA) and is often applied by nasal masks (nCPAP). The influence of nCPAP on the olfactory performance of OSA patients is unknown. The aim of this study was to assess the sense of smell before initiation of nCPAP and after three months treatment, in moderate and severe OSA patients. Methods The sense of smell was assessed in 35 patients suffering from daytime sleepiness and moderate to severe OSA (apnea/hypopnea index ≥ 15/h), with the aid of a validated test battery (Sniffin’ Sticks) before initiation of nCPAP therapy and after three months of treatment. Additionally, adherent subjects were included in a double-blind randomized three weeks CPAP-withdrawal trial (sub-therapeutic CPAP pressure). Results Twenty five of the 35 patients used the nCPAP therapy for more than four hours per night, and for more than 70% of nights (adherent group). The olfactory performance of these patients improved significantly (p = 0.007) after three months of nCPAP therapy. When considering the entire group of patients, olfaction also improved significantly (p = 0.001). In the randomized phase the sense of smell of six patients deteriorated under sub-therapeutic CPAP pressure (p = 0.046) whereas five patients in the maintenance CPAP group showed no significant difference (p = 0.501). Conclusions Olfactory performance improved significantly after three months of nCPAP therapy in patients suffering from moderate and severe OSA. It seems that this effect of nCPAP is reversible under sub-therapeutic CPAP pressure. Trial registration ISRCTN11128866 PMID:28158212

  10. Effects of Continuous Positive Airway Pressure on Neurocognitive Function in Obstructive Sleep Apnea Patients: The Apnea Positive Pressure Long-term Efficacy Study (APPLES)

    PubMed Central

    Kushida, Clete A.; Nichols, Deborah A.; Holmes, Tyson H.; Quan, Stuart F.; Walsh, James K.; Gottlieb, Daniel J.; Simon, Richard D.; Guilleminault, Christian; White, David P.; Goodwin, James L.; Schweitzer, Paula K.; Leary, Eileen B.; Hyde, Pamela R.; Hirshkowitz, Max; Green, Sylvan; McEvoy, Linda K.; Chan, Cynthia; Gevins, Alan; Kay, Gary G.; Bloch, Daniel A.; Crabtree, Tami; Dement, William C.

    2012-01-01

    Study Objective: To determine the neurocognitive effects of continuous positive airway pressure (CPAP) therapy on patients with obstructive sleep apnea (OSA). Design, Setting, and Participants: The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blind, 2-arm, sham-controlled, multicenter trial conducted at 5 U.S. university, hospital, or private practices. Of 1,516 participants enrolled, 1,105 were randomized, and 1,098 participants diagnosed with OSA contributed to the analysis of the primary outcome measures. Intervention: Active or sham CPAP Measurements: Three neurocognitive variables, each representing a neurocognitive domain: Pathfinder Number Test-Total Time (attention and psychomotor function [A/P]), Buschke Selective Reminding Test-Sum Recall (learning and memory [L/M]), and Sustained Working Memory Test-Overall Mid-Day Score (executive and frontal-lobe function [E/F]) Results: The primary neurocognitive analyses showed a difference between groups for only the E/F variable at the 2 month CPAP visit, but no difference at the 6 month CPAP visit or for the A/P or L/M variables at either the 2 or 6 month visits. When stratified by measures of OSA severity (AHI or oxygen saturation parameters), the primary E/F variable and one secondary E/F neurocognitive variable revealed transient differences between study arms for those with the most severe OSA. Participants in the active CPAP group had a significantly greater ability to remain awake whether measured subjectively by the Epworth Sleepiness Scale or objectively by the maintenance of wakefulness test. Conclusions: CPAP treatment improved both subjectively and objectively measured sleepiness, especially in individuals with severe OSA (AHI > 30). CPAP use resulted in mild, transient improvement in the most sensitive measures of executive and frontal-lobe function for those with severe disease, which suggests the existence of a complex OSA-neurocognitive relationship

  11. A randomised control study comparing the Infant Flow Driver with nasal continuous positive airway pressure in preterm infants

    PubMed Central

    Mazzella, M; Bellini, C; Calevo, M; Campone, F; Massocco, D; Mezzano, P; Zullino, E; Scopesi, F; Arioni, C; Bonacci, W; Serra, G

    2001-01-01

    OBJECTIVE—To compare the effectiveness of the Infant Flow Driver (IFD) with single prong nasal continuous positive airway pressure (nCPAP) in preterm neonates affected by respiratory distress syndrome.
DESIGN—Randomised controlled study.
PATIENTS—Between September 1997 and March 1999, 36 preterm infants who were eligible for CPAP treatment were randomly selected for either nCPAP or IFD and studied prospectively for changes in oxygen requirement and/or respiratory rate. The requirement for mechanical ventilation, complications of treatment, and effects on mid-term outcome were also evaluated.
RESULTS—Use of the IFD had a significantly beneficial effect on both oxygen requirement and respiratory rate (p < 0.0001) when compared with nCPAP. Moreover, O2 requirement and respiratory rate were significantly decreased by four hours (p < 0.001 and p < 0.03 respectively). The probability of remaining supplementary oxygen free over the first 48 hours of treatment was significantly higher in patients treated with the IFD than with nCPAP (p < 0.02). IFD treated patients had a higher success (weaning) rate (94% v 72%) and shorter duration of treatment (49.3 (31) v 56 (29.7) hours respectively; mean (SD)), although the difference was not significant.
CONCLUSIONS—IFD appears to be a feasible device for managing respiratory distress syndrome in preterm infants, and benefits may be had with regard to oxygen requirement and respiratory rate when compared with nCPAP. The trend towards reduced requirement for mechanical ventilation, shorter clinical recovery time, and shorter duration of treatment requires further evaluation in a multicentre randomised clinical trial.

 PMID:11517199

  12. Effects of continuous positive airway pressure on energy intake in obstructive sleep apnea: A pilot sham-controlled study

    PubMed Central

    Shechter, Ari; Kovtun, Kyle; St-Onge, Marie-Pierre

    2016-01-01

    Obesity is among the leading risk factors for obstructive sleep apnea (OSA). A reciprocal relationship between obesity and OSA has been proposed, which may be due to excessive food intake. We conducted a pilot study to test the effects of continuous positive airway pressure (CPAP) on energy intake (EI) in OSA patients using a sham-controlled crossover design. In-laboratory total daily EI was assessed after 2 mo of active and sham CPAP. Four men were enrolled (age ± SEM: 51.8 ± 2.1 y; body mass index: 31.5 ± 1.5 kg/m2). All received active treatment first. Meals (breakfast, lunch, dinner, snack) were served in excess portions at fixed times and additional palatable snacks were freely available throughout the day. Total EI was lower after active (3744 ± 511 kcal/d) vs. sham (4030 ± 456 kcal/d) CPAP but this difference was not significant (p = 0.51) due to variability in the free snack intake. When only fixed eating occasions were considered, daily EI was significantly lower in the active (3105 ± 513 kcal/d) vs. sham (3559 ± 420 kcal/d) condition (p = 0.006). This small pilot and feasibility study is the first to utilize a sham-controlled design to investigate the effects of CPAP treatment on objective measures of EI. Findings suggest that CPAP may cause a reduction in fixed meal intake. In demonstrating feasibility of study methodology, our study also suggests a larger randomized sham-controlled trial be conducted to fully characterize the effects of CPAP treatment on EI and energy balance overall. PMID:27769851

  13. Effect of ethanol on the efficacy of nasal continuous positive airway pressure as a treatment for obstructive sleep apnea.

    PubMed

    Berry, R B; Desa, M M; Light, R W

    1991-02-01

    The effect of ethanol ingestion on the efficacy of nasal continuous positive airway pressure (nasal CPAP) as a treatment for the obstructive sleep apnea (OSA) syndrome was studied in ten obese male subjects undergoing this therapy. On the first night of polysomnography, the lowest level of CPAP that maintained airway patency was determined (critical level). On the second (control) night (C), subjects slept the entire night on this level of CPAP. On the third night (E), subjects ingested either 1.5 ml/kg (part A, N = 6) or 2.0 ml/kg (part B, N = 4) of 50 percent ethanol (100 proof vodka) over one half-hour starting 1 h before bedtime. A serum ethanol level was obtained at bedtime (part A: 63.7 +/- 17.3 mg/dl; part B: 108.6 +/- 20.6 mg/dl), and subjects were monitored on the critical level of CPAP. Comparison of nights C and E for parts A + B showed no difference in total sleep time (TST) or the amount of different sleep stages as an absolute time or a percentage of TST except that there was more stage 2 (as a percent of TST) on E nights. The apnea + hypopnea index and C and E nights did not differ and was quite low (3.6 +/- 3.7/h vs 1.9 +/- 2.7/h). Similarly, ethanol ingestion did not increase the number of desaturations to at or below 90 and 85 percent, or lower the mean arterial oxygen saturation in NREM or REM sleep. Analysis of parts A and B separately also showed no differences with respect to the apnea + hypopnea index or the number of desaturations on control and ethanol nights. We conclude that acute moderate ethanol ingestion does not decrease the efficacy of an optimum level of nasal CPAP.

  14. Nasal CPAP

    MedlinePlus

    ... CPAP regularly, you may notice: Better concentration and memory Feeling more alert and less sleepy during the day Improved sleep for your bed partner Being more productive at work Less anxiety and depression and a better mood ...

  15. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  16. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  17. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  18. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  19. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  20. Efficacy of Home Single-Channel Nasal Pressure for Recommending Continuous Positive Airway Pressure Treatment in Sleep Apnea

    PubMed Central

    Masa, Juan F.; Duran-Cantolla, Joaquin; Capote, Francisco; Cabello, Marta; Abad, Jorge; Garcia-Rio, Francisco; Ferrer, Antoni; Fortuna, Ana M.; Gonzalez-Mangado, Nicolas; de la Peña, Monica; Aizpuru, Felipe; Barbe, Ferran; Montserrat, Jose M.; Larrateguy, Luis D.; de Castro, Jorge Rey; Garcia-Ledesma, Estefania; Corral, Jaime; Martin-Vicente, Maria J.; Martinez-Null, Cristina; Egea, Carlos; Cancelo, Laura; García-Díaz, Emilio; Carmona-Bernal, Carmen; Sánchez-Armengol, Ángeles; Mayos, Merche; Miralda, Rosa M; Troncoso, Maria F.; Gonzalez, Monica; Martinez-Martinez, Marian; Cantalejo, Olga; Piérola, Javier; Vigil, Laura; Embid, Cristina; del Mar Centelles, Mireia; Prieto, Teresa Ramírez; Rojo, Blas; Lores, Vanesa

    2015-01-01

    Introduction: Unlike other prevalent diseases, obstructive sleep apnea (OSA) has no simple tool for diagnosis and therapeutic decision-making in primary healthcare. Home single-channel nasal pressure (HNP) may be an alternative to polysomnography for diagnosis but its use in therapeutic decisions has yet to be explored. Objectives: To ascertain whether an automatically scored HNP apnea-hypopnea index (AHI), used alone to recommend continuous positive airway pressure (CPAP) treatment, agrees with decisions made by a specialist using polysomnography and several clinical variables. Methods: Patients referred by primary care physicians for OSA suspicion underwent randomized polysomnography and HNP. We analyzed the total sample and both more and less symptomatic subgroups for Bland and Altman plots to explore AHI agreement; receiver operating characteristic curves to establish area under the curve (AUC) measurements for CPAP recommendation; and therapeutic decision efficacy for several HNP AHI cutoff points. Results: Of the 787 randomized patients, 35 (4%) were lost, 378 (48%) formed the more symptomatic and 374 (48%) the less symptomatic subgroups. AHI bias and agreement limits were 5.8 ± 39.6 for the total sample, 5.3 ± 38.7 for the more symptomatic, and 6 ± 40.2 for the less symptomatic subgroups. The AUC were 0.826 for the total sample, 0.903 for the more symptomatic, and 0.772 for the less symptomatic subgroups. In the more symptomatic subgroup, 70% of patients could be correctly treated with CPAP. Conclusion: Automatic home single-channel nasal pressure scoring can correctly recommend CPAP treatment in most of more symptomatic patients with OSA suspicion. Our results suggest that this device may be an interesting tool in initial OSA management for primary care physicians, although future studies in a primary care setting are necessary. Clinical Trials Information: Clinicaltrial.gov identifier: NCT01347398. Citation: Masa JF, Duran-Cantolla J, Capote F, Cabello

  1. Cost-effectiveness of Out-of-Hospital Continuous Positive Airway Pressure for Acute Respiratory Failure

    PubMed Central

    Thokala, Praveen; Goodacre, Steve; Ward, Matt; Penn-Ashman, Jerry; Perkins, Gavin D.

    2015-01-01

    Study objective We determine the cost-effectiveness of out-of-hospital continuous positive airway pressure (CPAP) compared with standard care for adults presenting to emergency medical services with acute respiratory failure. Methods We developed an economic model using a United Kingdom health care system perspective to compare the costs and health outcomes of out-of-hospital CPAP to standard care (inhospital noninvasive ventilation) when applied to a hypothetical cohort of patients with acute respiratory failure. The model assigned each patient a probability of intubation or death, depending on the patient’s characteristics and whether he or she had out-of-hospital CPAP or standard care. The patients who survived accrued lifetime quality-adjusted life-years (QALYs) and health care costs according to their age and sex. Costs were accrued through intervention and hospital treatment costs, which depended on patient outcomes. All results were converted into US dollars, using the Organisation for Economic Co-operation and Development purchasing power parities rates. Results Out-of-hospital CPAP was more effective than standard care but was also more expensive, with an incremental cost-effectiveness ratio of £20,514 per QALY ($29,720/QALY) and a 49.5% probability of being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold. The probability of out-of-hospital CPAP’s being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold depended on the incidence of eligible patients and varied from 35.4% when a low estimate of incidence was used to 93.8% with a high estimate. Variation in the incidence of eligible patients also had a marked influence on the expected value of sample information for a future randomized trial. Conclusion The cost-effectiveness of out-of-hospital CPAP is uncertain. The incidence of patients eligible for out-of-hospital CPAP appears to be the key determinant of cost-effectiveness. PMID:25737210

  2. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update

    PubMed Central

    Johnson, Karin Gardner; Johnson, Douglas Clark

    2015-01-01

    Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features. PMID:26604837

  3. Effects of continuous positive airway pressure treatment on clinic and ambulatory blood pressures in patients with obstructive sleep apnea and resistant hypertension: a randomized controlled trial.

    PubMed

    Muxfeldt, Elizabeth S; Margallo, Victor; Costa, Leonardo M S; Guimarães, Gleison; Cavalcante, Aline H; Azevedo, João C M; de Souza, Fabio; Cardoso, Claudia R L; Salles, Gil F

    2015-04-01

    The effect of continuous positive airway pressure (CPAP) on blood pressures (BPs) in patients with resistant hypertension and obstructive sleep apnea is not established. We aimed to evaluate it in a randomized controlled clinical trial, with blinded assessment of outcomes. Four hundred thirty-four resistant hypertensive patients were screened and 117 patients with moderate/severe obstructive sleep apnea, defined by an apnea-hypopnea index ≥15 per hour, were randomized to 6-month CPAP treatment (57 patients) or no therapy (60 patients), while maintaining antihypertensive treatment. Clinic and 24-hour ambulatory BPs were obtained before and after 6-month treatment. Primary outcomes were changes in clinic and ambulatory BPs and in nocturnal BP fall patterns. Intention-to-treat and per-protocol (limited to those with uncontrolled ambulatory BPs) analyses were performed. Patients had mean (SD) 24-hour BP of 129(16)/75(12) mm Hg, and 59% had uncontrolled ambulatory BPs. Mean apnea-hypopnea index was 41 per hour and 58.5% had severe obstructive sleep apnea. On intention-to-treat analysis, there was no significant difference in any BP change, neither in nocturnal BP fall, between CPAP and control groups. The best effect of CPAP was on night-time systolic blood pressure in per-protocol analysis, with greater reduction of 4.7 mm Hg (95% confidence interval, -11.3 to +3.1 mm Hg; P=0.24) and an increase in nocturnal BP fall of 2.2% (95% confidence interval, -1.6% to +5.8%; P=0.25), in comparison with control group. In conclusion, CPAP treatment had no significant effect on clinic and ambulatory BPs in patients with resistant hypertension and moderate/severe obstructive sleep apnea, although a beneficial effect on night-time systolic blood pressure and on nocturnal BP fall might exist in patients with uncontrolled ambulatory BP levels.

  4. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  5. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  6. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  7. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  8. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  9. Long-term effects of treatment with nasal continuous positive airway pressure on lung function in patients with overlap syndrome.

    PubMed

    de Miguel, Javier; Cabello, Jorge; Sánchez-Alarcos, José M F; Alvarez-Sala, Rudolfo; Espinós, Domingo; Alvarez-Sala, José L

    2002-03-01

    We assessed the effects of chronic nasal continuous positive airway pressure (CPAP) therapy on lung function in a series of unselected patients with overlap syndrome, and we determined whether there were differences in the response induced by CPAP between hypercapnic (PaCO2 > or =45 mm Hg) and eucapnic patients with overlap syndrome. The study population included 55 unselected patients (48 men, mean age of 58.5 +/- 10.5 years) with a concurrent diagnosis of chronic obstructive pulmonary disease (COPD) and obstructive sleep apnea-hypopnea syndrome (OSAHS) who had been referred to the Department of Pulmonology of our hospital over 2 consecutive years and in whom work-up studies resulted in the prescription of nasal CPAP therapy. An apnea-hypopnea index (AHI) greater than or equal to 10 in the cardiorespiratory polygraphy was required for the diagnosis of OSAHS. A forced expiratory volume in one second (FEV1) less than 80% and FEV1-forced vital capacity (FVC) ratio less than 70% of the reference values were required for the diagnosis of COPD. Control lung function studies and arterial blood gas measurements were performed at 6 and 18 months of CPAP therapy. These patients with overlap syndrome accounted for 28.5% of all patients with OSAHS treated with CPAP during the study period. The mean AHI was 37.3 +/- 26.1 and the mean CPAP level 7.3 +/- 1.3 cm H2O. Thirty-three patients were hypercapnic (PaCO2 > or = 45 mm Hg) and 22 eucapnic. The hypercapnic group had higher AHI value (44.3 +/- 26.9) than the eucapnic group (28.6 +/- 21.9) (P < 0.05). After 6 months of CPAP therapy, there were statistically significant increases in PaO2, FEV1, and FVC, accompanied by significant decreases in PaCO2, serum bicarbonate levels, and alveolar-arterial oxygen difference. Response of overlap syndrome patients to CPAP therapy was superior in the hypercapnic group, particularly in relation to improvement of arterial blood gases. However, statistically significant differences in all

  10. Impact of a New Nasal Pillows Mask on Patients' Acceptance, Compliance, and Willingness to Remain on CPAP Therapy.

    PubMed

    Wimms, Alison; Ketheeswaran, Sahisha; Ziegenbein, Claus; Jennings, Laura; Woehrle, Holger

    2016-01-01

    Aim. Continuous positive airway pressure (CPAP) masks are a key factor in patient compliance. This program assessed the performance of a new nasal pillows mask (NPM) on a variety of new and established obstructive sleep apnea (OSA) patients using CPAP therapy. Methods. Five programs were developed to assess the new NPM [AirFit P10, ResMed] on naïve patients; patients established on another NPM; patients using a nasal mask; patients with low CPAP compliance; and patients who wished to stop using CPAP therapy. Results. A total of 212 patients were included. In naïve patients, CPAP usage after 3 months was 5.9 ± 1.7 hours/night, compared with the control group at 4.6 ± 2.4 hours/night (p < 0.05). In patients established on another NPM, usage improved to 7.4 ± 1.1 hours/night versus 6.7 ± 1.4 (p = 0.001). 78% of nasal mask users wished to continue using the new NPM. Low compliance patients improved with an average of 0.87 hours/night (p = 0.001) when using the new NPM. In patients at the point of quitting CPAP, 60% continued with therapy using the new NPM. Conclusion. The new NPM mask performed well in a variety of clinical groups of OSA patients receiving CPAP therapy and shows that technical advances in CPAP masks can improve patient compliance.

  11. Impact of a New Nasal Pillows Mask on Patients' Acceptance, Compliance, and Willingness to Remain on CPAP Therapy

    PubMed Central

    Ketheeswaran, Sahisha; Jennings, Laura; Woehrle, Holger

    2016-01-01

    Aim. Continuous positive airway pressure (CPAP) masks are a key factor in patient compliance. This program assessed the performance of a new nasal pillows mask (NPM) on a variety of new and established obstructive sleep apnea (OSA) patients using CPAP therapy. Methods. Five programs were developed to assess the new NPM [AirFit P10, ResMed] on naïve patients; patients established on another NPM; patients using a nasal mask; patients with low CPAP compliance; and patients who wished to stop using CPAP therapy. Results. A total of 212 patients were included. In naïve patients, CPAP usage after 3 months was 5.9 ± 1.7 hours/night, compared with the control group at 4.6 ± 2.4 hours/night (p < 0.05). In patients established on another NPM, usage improved to 7.4 ± 1.1 hours/night versus 6.7 ± 1.4 (p = 0.001). 78% of nasal mask users wished to continue using the new NPM. Low compliance patients improved with an average of 0.87 hours/night (p = 0.001) when using the new NPM. In patients at the point of quitting CPAP, 60% continued with therapy using the new NPM. Conclusion. The new NPM mask performed well in a variety of clinical groups of OSA patients receiving CPAP therapy and shows that technical advances in CPAP masks can improve patient compliance. PMID:27648308

  12. Use of Nasal Bubble CPAP in Children with Hypoxemic Clinical Pneumonia—Report from a Resource Limited Set-Up

    PubMed Central

    KiranBabu, HB; Singhi, Sunit; Nallasamy, Karthi

    2016-01-01

    Objective: Nasal bubble continuous positive airway pressure (bCPAP) is preferred in developing economies for easy applicability and low cost. Because its use in older children is unexplored, we sought to evaluate its utility in hypoxemic clinical pneumonia. Methods: Of 330 children (1 month–12 years) with clinical pneumonia enrolled prospectively over 1 year, those with increased work of breathing and/or SpO2 <92% received bCPAP delivered via an underwater ‘T' tube through nasal prongs. Proportion requiring intubation despite bCPAP constituted primary outcome. Incidence of complications, duration of bCPAP and emergency stay were secondary outcomes. Results: Oxygen was initiated by nasal prongs (NPO2) in 204 (61.8%), and by bCPAP in 110 (33.3%). Sixteen (4.8%) were intubated at the outset. Fifty-three (25.9%) on NPO2 were shifted to bCPAP for worsening distress and hypoxemia. Only three (1.8%) from bCPAP group required intubation, of which one died. Failure rate and complications were negligent. The median emergency stay was 4 days. Conclusions: Nasal bCPAP was safe and effective in children with hypoxemic clinical pneumonia. PMID:26428195

  13. Efficacy of continuous positive airway pressure treatment on 5-year survival in patients with ischaemic stroke and obstructive sleep apnea: a randomized controlled trial.

    PubMed

    Parra, Olga; Sánchez-Armengol, Ángeles; Capote, Francisco; Bonnin, Marc; Arboix, Adrià; Campos-Rodríguez, Francisco; Pérez-Ronchel, José; Durán-Cantolla, Joaquín; Martínez-Null, Cristina; de la Peña, Mónica; Jiménez, Maria Carmen; Masa, Fernando; Casadon, Ignacio; Alonso, Maria Luz; Macarrón, José L

    2015-02-01

    The main purpose of the present analysis is to assess the influence of introducing early nasal continuous positive airway pressure (nCPAP) treatment on cardiovascular recurrences and mortality in patients with a first-ever ischaemic stroke and moderate-severe obstructive sleep apnea (OSA) with an apnea-hypopnea index (AHI) ≥20 events h(-1) during a 5-year follow-up. Patients received conventional treatment for stroke and were assigned randomly to the nCPAP group (n = 71) or the control group (n = 69). Cardiovascular events and mortality were registered for all patients. Survival and cardiovascular event-free survival analysis were performed after 5-year follow-up using the Kaplan-Meier test. Patients in the nCPAP group had significantly higher cardiovascular survival than the control group (100 versus 89.9%, log-rank test 5.887; P = 0.015) However, and also despite a positive tendency, there were no significant differences in the cardiovascular event-free survival at 68 months between the nCPAP and control groups (89.5 versus 75.4%, log-rank test 3.565; P = 0.059). Early nCPAP therapy has a positive effect on long-term survival in ischaemic stroke patients and moderate-severe OSA.

  14. Sleep-related breathing disorders. 5. Nasal continuous positive airway pressure treatment for obstructive sleep apnoea.

    PubMed

    Grunstein, R R

    1995-10-01

    CPAP should be considered the first line of treatment in patients with moderate to severe obstructive sleep apnoea. In our centre in Sydney this generally means patients with more than 20 apnoea/hypopnoeas per hour with repeated dips in oxyhaemoglobin saturation and usually some symptomatology. Despite this first line role of nasal CPAP, recent objective studies question whether earlier enthusiastic reports on adherence to CPAP are correct. The role of technical innovations in new CPAP machines in improving usage remains to be tested. The "drop out" rate from physician selection for a CPAP trial to highly compliant user is certainly more than 50% of patients. What happens to these patients? Data from some studies suggest that surgical treatments are used, at least in the USA, but in all probability many of these patients remain untreated. The challenge in the next decade is either to improve CPAP devices to increase usage in this group or to develop other treatment options. The role of intensive inhospital "acclimatisation" to CPAP also has yet to be objectively tested. It is unclear whether "intelligent" CPAP will make huge inroads in increasing the number of patients who accept CPAP trials, prescriptions, or compliance. It will have minimal impact on patients with mask problems or claustrophobia or those who feel that CPAP is inconvenient. There is a high likelihood that it will reduce technologist workload during CPAP titration studies. "Intelligent" CPAP may help to reduce total overnight mouth leakage and therefore reduce nasal side effects. The current expense of developing such devices will mean that they are unlikely to supersede much cheaper standard "one pressure" CPAP machines in the next few years.

  15. Pain Intensity and Opioid Utilization in Response to CPAP Therapy in Veterans with Obstructive Sleep Apnea on Chronic Opioid Treatment

    PubMed Central

    Jaoude, Philippe; Lal, Ashima; Vermont, Leah; Porhomayon, Jahan; El-Solh, Ali A.

    2016-01-01

    Study Objectives: Sleep fragmentation has been linked to poor pain tolerance and lowered pain threshold. Little evidence exists on whether continuous positive airway pressure (CPAP) adherence in veterans with obstructive sleep apnea (OSA) who are taking opioids for non-malignant pain would ameliorate pain and reduce consumption of opioids. Methods: A retrospective case-control study was performed at a VA sleep center. Pain intensity was assessed using the Numerical Categorical Scale prior to CPAP treatment and 12-mo follow-up. Opioids intake was assessed using the morphine equivalent daily dose (MEDD). Adherence to CPAP was evaluated with the built-in meter. Results: We reviewed 113 patients with OSA (apnea-hypopnea index [AHI] 35.9 ± 29.5) using a MEDD of 61.6 mg (range 5–980 mg) and a control group of 113 veterans with OSA (AHI 33.4 ± 27.3) on no opioids treatment. CPAP adherence was significantly lower at 12 mo in opioid-treated patients compared to controls (37% versus 55%; p = 0.01). Greater pain intensity was the only independent variable associated with CPAP non-adherence at 12-mo follow-up (p = 0.03). Compared to baseline, no significant difference was observed in pain intensity or consumption of opioids in CPAP adherent patients. Conclusions: CPAP treatment did not reduce pain intensity or consumption of opioids in veterans with chronic pain who have coexisting OSA. CPAP adherence was lower in opioid-treated veterans with OSA compared to opioid-free veterans with OSA. Pain intensity was the only determinant of CPAP adherence. Future studies are needed to evaluate pain management program on adherence to CPAP. Citation: Jaoude P, Lal A, Vermont L, Porhomayon J, El-Solh AA. Pain intensity and opioid utilization in response to cpap therapy in veterans with obstructive sleep apnea on chronic opioid treatment. J Clin Sleep Med 2016;12(8):1105–1111. PMID:27250815

  16. Continuous positive airway pressure for sleep apnoea/hypopnoea syndrome: usefulness of a 2 week trial to identify factors associated with long term use

    PubMed Central

    Popescu, G; Latham, M; Allgar, V; Elliott, M

    2001-01-01

    BACKGROUND—The sleep apnoea/hypopnoea syndrome (SAHS) is common and treatment with continuous positive airway pressure (CPAP) is effective. However, not all patients can cope with the demands of using mask positive pressure. Compliance can be improved with an intensive educational programme and patient support, but this is not practical in most centres given the large numbers of patients coming forward for treatment. Several studies have evaluated correlations between various parameters at diagnosis in order to anticipate patients' behaviour and to avoid the social and health implications of undertreated SAHS. We have evaluated the use of additional data derived during a 2 week home CPAP trial to identify factors associated with longer term use of CPAP and compliance.
METHODS—Following a diagnostic study, 209 patients were offered a CPAP machine for a 2 week home trial. After completing the trial, patients were reassessed and scored their overall satisfaction with CPAP treatment on a five point scale ranging from "much worse" to "much better" and an Epworth score relating to the loan period. Machine run time was recorded from the integral clock. These data were added to those available at diagnosis to construct models indicative of continuing CPAP and average nightly use at 1year.
RESULTS—209 patients were offered the 2 week loan at least a year before June 1999 (90.9% men, mean (SD) age 51.0 (10.6) years, body mass index (BMI) 34.6 (7.7) kg/m2, Epworth score 15 (IQR 11-18), apnoea/hypopnoea index (AHI) 38.1(22.9) events/h). 153 patients (73.2%) opted to continue CPAP and 56 declined. One year later data were available for 187 patients; 128 (68.5% on an intention to treat analysis) continued to use the machine with a mean use of 5.0 (2.4) hours/night. A logistic regression model indicated that mean CPAP use during the loan period and the overall satisfaction score accurately defined continuing CPAP and "satisfactory" CPAP use at 1 year. For patients with

  17. Efficacy and safety of CPAP in low- and middle-income countries

    PubMed Central

    Thukral, A; Sankar, M J; Chandrasekaran, A; Agarwal, R; Paul, V K

    2016-01-01

    We conducted a systematic review to evaluate the (1) feasibility and efficacy and (2) safety and cost effectiveness of continuous positive airway pressure (CPAP) therapy in low- and middle-income countries (LMIC). We searched the following electronic bibliographic databases—MEDLINE, Cochrane CENTRAL, CINAHL, EMBASE and WHOLIS—up to December 2014 and included all studies that enrolled neonates requiring CPAP therapy for any indication. We did not find any randomized trials from LMICs that have evaluated the efficacy of CPAP therapy. Pooled analysis of four observational studies showed 66% reduction in in-hospital mortality following CPAP in preterm neonates (odds ratio 0.34, 95% confidence interval (CI) 0.14 to 0.82). One study reported 50% reduction in the need for mechanical ventilation following the introduction of bubble CPAP (relative risk 0.5, 95% CI 0.37 to 0.66). The proportion of neonates who failed CPAP and required mechanical ventilation varied from 20 to 40% (eight studies). The incidence of air leaks varied from 0 to 7.2% (nine studies). One study reported a significant reduction in the cost of surfactant usage with the introduction of CPAP. Available evidence suggests that CPAP is a safe and effective mode of therapy in preterm neonates with respiratory distress in LMICs. It reduces the in-hospital mortality and the need for ventilation thereby minimizing the need for up-transfer to a referral hospital. But given the overall paucity of studies and the low quality evidence underscores the need for large high-quality studies on the safety, efficacy and cost effectiveness of CPAP therapy in these settings. PMID:27109089

  18. A Pilot Study of CPAP Adherence Promotion by Peer Buddies with Sleep Apnea

    PubMed Central

    Parthasarathy, Sairam; Wendel, Christopher; Haynes, Patricia L.; Atwood, Charles; Kuna, Samuel

    2013-01-01

    Study Objectives: To evaluate patient ratings of the acceptability of a peer buddy system (PBS). To promote continuous positive airway pressure (CPAP) therapy adherence in patients with obstructive sleep apnea (OSA). To obtain preliminary data on the effectiveness of PBS on sleep-specific health-related quality of life and CPAP adherence. Design: Prospective, randomized, and controlled study. Setting: Academic Center. Participants: Thirty-nine patients with OSA and 13 patients with OSA who were experienced CPAP users. Interventions: Recently diagnosed patients with OSA were randomly assigned to either the PBS to promote CPAP adherence (intervention group) or usual care (control group). Measurements: Patient satisfaction, Functional Outcomes of Sleep Questionnaire (FOSQ), CPAP adherence, vigilance, self-efficacy, and patient activation were measured. Results: Ninety-one percent of the subjects rated the PBS as very satisfactory (68%) or satisfactory (23%). During the 90 days of therapy, weekly CPAP adherence was greater in the intervention than the usual care group (MANOVA; F = 2.29; p = 0.04). Patient satisfaction was positively correlated with CPAP adherence (R2 = 0.14; p = 0.02). We did not find any group differences for FOSQ, vigilance, self-efficacy, or patient activation in this pilot study. Conclusion: Our pilot study suggests that the PBS intervention is feasible and received high patient satisfaction ratings. CPAP adherence may be improved by peer-driven intervention, but a larger, adequately powered study is needed. Clinical Trial Information: ClinicalTrials.gov identifier: NCT01164683. Commentary: A commentary on this article appears in this issue on page 551. Citation: Parthasarathy S; Wendel C; Haynes PL; Atwood C; Kuna S. A pilot study of CPAP adherence promotion by peer buddies with sleep apnea. J Clin Sleep Med 2013;9(6):543-550. PMID:23772186

  19. Effect of CPAP on blood pressure in patients with minimally symptomatic obstructive sleep apnoea: a meta-analysis using individual patient data from four randomised controlled trials

    PubMed Central

    Bratton, Daniel J; Stradling, John R; Barbé, Ferran; Kohler, Malcolm

    2014-01-01

    Background CPAP reduces blood pressure (BP) in patients with symptomatic obstructive sleep apnoea (OSA). Whether the same benefit is present in patients with minimally symptomatic OSA is unclear, thus a meta-analysis of existing trial data is required. Methods The electronic databases Medline, Embase and trial registries were searched. Trials were eligible if they included patients with minimally symptomatic OSA, had randomised them to receive CPAP or either sham-CPAP or no CPAP, and recorded BP at baseline and follow-up. Individual participant data were obtained. Primary outcomes were absolute change in systolic and diastolic BP. Findings Five eligible trials were found (1219 patients) from which data from four studies (1206 patients) were obtained. Mean (SD) baseline systolic and diastolic BP across all four studies was 131.2 (15.8) mm Hg and 80.9 (10.4) mm Hg, respectively. There was a slight increase in systolic BP of 1.1 mm Hg (95% CI −0.2 to 2.3, p=0.086) and a slight reduction in diastolic BP of 0.8 mm Hg (95% CI −1.6 to 0.1, p=0.083), although the results were not statistically significant. There was some evidence of an increase in systolic BP in patients using CPAP <4 h/night (1.5 mm Hg, 95% CI −0.0 to 3.1, p=0.052) and reduction in diastolic BP in patients using CPAP >4 h/night (−1.4 mm Hg, 95% CI −2.5 to −0.4, p=0.008). CPAP treatment reduced both subjective sleepiness (p<0.001) and OSA severity (p<0.001). Interpretation Although CPAP treatment reduces OSA severity and sleepiness, it seems not to have a beneficial effect on BP in patients with minimally symptomatic OSA, except in patients who used CPAP for >4 h/night. PMID:24947425

  20. Effects of Use of a Continuous Positive Airway Pressure Device on Glaucoma

    PubMed Central

    Ulusoy, Seckin; Erden, Meltem; Dinc, Mehmet Emre; Yavuz, Nurdogan; Caglar, Erdem; Dalgic, Abdullah; Erdogan, Coskun

    2015-01-01

    Background The aim of this study was to investigate the prevalence of glaucoma in obstructive sleep apnea syndrome (OSAS) and to determine the efficacy of the equipment used in the treatment of this disease. Material/Methods In this cross-sectional study, 38 patients with OSAS used the continuous positive airway pressure (CPAP) device (Group 1) and 32 patients with OSAS refused CPAP device (Group 2). Thirty-six patients did not have OSAS (Group 3). Results Patient age, gender, height, weight, and neck circumference did not differ among groups (p>0.05); and the apnea-hypopnea index (AHI) and respiratory disturbance index (RDI) values did not differ between Groups 1 and 2 (p>0.05). Vision and pachymetric values did not differ among groups (p>0.05). The IOP was significantly higher in Group 2 than in Group 1 (p<0.05) but did not differ between Groups 1 and 3 (p>0.05). The fundus C/D ratio was significantly higher (p<0.05) in Group 2 than in the other groups but did not differ between Groups 1 and 3 (p>0.05). In Group 1, 2, and 3, 5.2%, 12.5%, and 0%, respectively, of patients had glaucoma. Conclusions OSAS should be considered a significant risk factor for glaucoma. Eye tests may help to identify individuals with undiagnosed OSAS, and such testing of patients with diagnosed OSAS may allow early detection of glaucoma and referral of such patients for CPAP therapy to prevent development of complications. PMID:26547930

  1. Efficiency of cold passover and heated humidification under continuous positive airway pressure.

    PubMed

    Randerath, W J; Meier, J; Genger, H; Domanski, U; Rühle, K H

    2002-07-01

    Cold passover and heated humidifiers are employed for the prevention of side-effects associated with continuous positive airway pressure (CPAP) treatment. However, to date, it has not been possible to separately measure the humidity of inspired and expired air. The aim of this study was to compare the relative humidity of the inspired air and the water loss during respiration between cold passover and heated humidifiers under CPAP. Humidity and temperature were determined separately for the respiratory phases, without humidification, with cold passover and heated humidifiers in 10 healthy subjects. Humidity was measured with a capacitive hygrometer, temperature with a "Type K" thermosensor, and impedance of the total respiratory system with impulse oscillometry. The relative humidity (rH) of the inspired air (mean+/-SD) increased significantly from 24.0+/-9.1%, rH (34.8+/-1.0 degrees C, no humidifier) to 34.5+/-10.1%, rH (34.6+/-1.0 degrees C) under cold humidification, and to 53.9+/-13.2% rH (35.0+/-1.1 degrees C) under heated humidification. With heated humidification, water loss was reduced by 38% compared to cold humidification. The impedance increased from 5.7+/-1.8 cmH2O x L x s(-1) (no humidifier) to 6.7+/-1.8 cmH2O x L x s(-1) (heated humidifier). The authors conclude that the use of a heated humidifier during continuous positive airway pressure appreciably increases the relative humidity of the inspired air and reduces the water loss during respiration.

  2. The use of auto-titrating continuous positive airway pressure for treatment of adult obstructive sleep apnea. An American Academy of Sleep Medicine review.

    PubMed

    Berry, Richard B; Parish, James M; Hartse, Kristyna M

    2002-03-15

    This paper reviews the efficacy of auto-titrating continuous positive airway pressure (APAP) for treatment of obstructive sleep apnea. It is based on a review of 30 articles published in peer review journals conducted by a task force appointed by the American Academy of Sleep Medicine to develop practice parameters for use of APAP devices for treatment of obstructive sleep apnea (OSA). The data indicate that APAP can be used to treat many patients with OSA (auto-adjusting) or to identify an effective optimal fixed level of continuous positive airway pressure (CPAP) for treatment (auto-titration). Patients with significant congestive heart failure, chronic obstructive pulmonary disease (COPD), or significant amounts of central apnea were excluded from many treatment trials and there is insufficient evidence that APAP can be used to treat these patients. Many clinical trials have been performed in patients already on CPAP or with the initial APAP night in a laboratory setting. At this time only a few studies have evaluated initial titration with APAP in CPAP-naïve patients in an unattended setting. Further studies of APAP in this circumstance are needed. No studies have systematically compared the efficacy of one APAP technology with another. Devices using different technology may not give the same results in a given patient. Devices solely dependent on vibration may not work in non-snorers or patient who have undergone upper-airway surgery. High mask or mouth leaks may prevent adequate titration in devices monitoring snoring, flow, or impedance (forced oscillation technique). Review of the raw data to identify periods of high leak was performed in several of the APAP titration studies, to identify a pressure for fixed CPAP treatment or to determine if the titration was adequate. There is conflicting evidence for and against the premise that treatment with APAP increases acceptance and adherence compared to fixed CPAP. In studies demonstrating an increase in

  3. CPAP Treatment Partly Normalizes Sleep Spindle Features in Obstructive Sleep Apnea

    PubMed Central

    Saunamäki, Tiia; Huupponen, Eero; Loponen, Juho

    2017-01-01

    Objective. Obstructive sleep apnea (OSA) decreases sleep spindle density and frequency. We evaluated the effects of continuous positive airway pressure (CPAP) treatment on different features of sleep spindles. Methods. Twenty OSA patients underwent two night polysomnographies in a diagnostic phase and one night polysomnography after 6 months of CPAP treatment. The control group comprised 20 healthy controls. Sleep spindles were analyzed by a previously developed automated method. Unilateral and bilateral spindles were identified in central and frontopolar brain locations. Spindle density and frequency were determined for the first and last half of the NREM time. Results. The density of bilateral central spindles, which did not change in the untreated OSA patients, increased towards the morning hours during CPAP treatment and in the controls. Central spindles did not become faster with sleep in OSA patients and the central spindles remained slow in the left hemisphere even with CPAP. Conclusion. CPAP treatment normalized spindle features only partially. The changes may be associated with deficits in thalamocortical spindle generating loops. Significance. This study shows that some sleep spindle changes persist after CPAP treatment in OSA patients. The association of these changes to daytime symptoms in OSA patients needs to be further evaluated. PMID:28261503

  4. Non-CPAP therapies in obstructive sleep apnoea: mandibular advancement device therapy.

    PubMed

    Marklund, Marie; Verbraecken, Johan; Randerath, Winfried

    2012-05-01

    Mandibular advancement devices (MADs) represent the main non-continuous positive airway pressure (non-CPAP) therapy for patients with obstructive sleep apnoea (OSA). The aim of the European Respiratory Society Task Force was to review the evidence in favour of MAD therapy. Effects of tongue-retaining devices are not included in this report. Custom-made MADs reduce apnoea/hypopnoea index (AHI) and daytime sleepiness compared with placebo devices. CPAP more effectively diminishes AHI, while increasing data suggest fairly similar outcomes in relation to symptoms and cardiovascular health from these treatments. Patients often prefer MADs to CPAP. Milder cases and patients with a proven increase in upper airway size as a result of mandibular advancement are most likely to experience treatment success with MADs. A custom-made device titrated from an initial 50% of maximum mandibular advancement has been recommended. More research is needed to define the patients who will benefit from MAD treatment compared with CPAP, in terms of the effects on sleep-disordered breathing and on other diseases related to OSA. In conclusion, MADs are recommended for patients with mild to moderate OSA (Recommendation Level A) and for those who do not tolerate CPAP. The treatment must be followed up and the device adjusted or exchanged in relation to the outcome.

  5. CPAP Treatment Adherence in Women with Obstructive Sleep Apnea

    PubMed Central

    Baltzan, M.; Pavilanis, A.; Tran, D.-L.; Conrod, K.

    2017-01-01

    Untreated obstructive sleep apnea (OSA) has numerous negative health-related consequences. Continuous positive airway pressure (CPAP) is generally considered the treatment of choice for OSA, but rates of nonadherence are high. It is believed that OSA is more prevalent among men; therefore understanding how OSA presents among women is limited and treatment adherence has received little research attention. For this study, 29 women were recruited from primary care offices. They completed a questionnaire battery and underwent a night of nocturnal polysomnography (PSG) followed by a visit with a sleep specialist. Women diagnosed with OSA were prescribed CPAP; 2 years later CPAP adherence was evaluated. Results show that approximately half the sample was adherent. There were no significant differences between adherent and nonadherent women on OSA severity; however CPAP adherent women had worse nocturnal and daytime functioning scores at the time of diagnosis. Moreover, when the seven nocturnal and daytime variables were used as predictors in a discriminant analysis, they could predict 87% of adherent and 93% of the nonadherent women. The single most important predictor was nonrefreshing sleep. We discuss the implications of the findings for identifying women in primary care with potential OSA and offer suggestions for enhancing treatment adherence. PMID:28352476

  6. CPAP Treatment Adherence in Women with Obstructive Sleep Apnea.

    PubMed

    Libman, E; Bailes, S; Fichten, C S; Rizzo, D; Creti, L; Baltzan, M; Grad, R; Pavilanis, A; Tran, D-L; Conrod, K; Amsel, R

    2017-01-01

    Untreated obstructive sleep apnea (OSA) has numerous negative health-related consequences. Continuous positive airway pressure (CPAP) is generally considered the treatment of choice for OSA, but rates of nonadherence are high. It is believed that OSA is more prevalent among men; therefore understanding how OSA presents among women is limited and treatment adherence has received little research attention. For this study, 29 women were recruited from primary care offices. They completed a questionnaire battery and underwent a night of nocturnal polysomnography (PSG) followed by a visit with a sleep specialist. Women diagnosed with OSA were prescribed CPAP; 2 years later CPAP adherence was evaluated. Results show that approximately half the sample was adherent. There were no significant differences between adherent and nonadherent women on OSA severity; however CPAP adherent women had worse nocturnal and daytime functioning scores at the time of diagnosis. Moreover, when the seven nocturnal and daytime variables were used as predictors in a discriminant analysis, they could predict 87% of adherent and 93% of the nonadherent women. The single most important predictor was nonrefreshing sleep. We discuss the implications of the findings for identifying women in primary care with potential OSA and offer suggestions for enhancing treatment adherence.

  7. Effects of Heated Humidification and Topical Steroids on Compliance, Nasal Symptoms, and Quality of Life in Patients with Obstructive Sleep Apnea Syndrome Using Nasal Continuous Positive Airway Pressure

    PubMed Central

    Ryan, Silke; Doherty, Liam S.; Nolan, Geraldine M.; McNicholas, Walter T.

    2009-01-01

    Background: Nasal side effects are common in patients with obstructive sleep apnea syndrome (OSAS) starting on nasal continuous positive airway pressure (CPAP) therapy. We tested the hypothesis that heated humidification or nasal topical steroids improve compliance, nasal side effects and quality of life in this patient group. Methods: 125 patients with the established diagnosis of OSAS (apnea/hypopnea index ≥ 10/h), who tolerated CPAP via a nasal mask, and who had a successful CPAP titration were randomized to 4 weeks of dry CPAP, humidified CPAP or CPAP with additional topical nasal steroid application (fluticasone, GlaxoWellcome). Groups were similar in all demographic variables and in frequency of nasal symptoms at baseline. Outcome measures were objective compliance, quality of life (short form 36), subjective sleepiness (Epworth Sleepiness Scale score) and nasal symptoms such as runny, dry or blocked nose, sneezing and headaches; all variables assessed using a validated questionnaire and by direct interview. Results: There was no difference in compliance between groups after 4 weeks (dry: 5.21 ± 1.66 h/night, fluticasone: 5.66 ± 1.68, humidifier: 5.21 ± 1.84; p = 0.444). Quality of life and subjective sleepiness improved in all groups, but there were no differences in the extent of improvement. Nasal Symptoms were less frequently reported in the humidifier group (28%) than in the remaining groups (dry: 70%, fluticasone: 53%, p = 0.002). However, the addition of fluticasone resulted in increased frequency of sneezing. Conclusion: The addition of a humidifier, but not nasal steroids decreases the frequency of nasal symptoms in unselected OSAS patients initiating CPAP therapy; however compliance and quality of life remain unaltered. Citation: Ryan S; Doherty LS; Nolan GM; McNicholas WT. Effects of heated humidification and topical steroids on compliance, nasal symptoms, and quality of life in patients with obstructive sleep apnea syndrome using nasal

  8. Oxidative stress mediated arterial dysfunction in patients with obstructive sleep apnoea and the effect of continuous positive airway pressure treatment

    PubMed Central

    2012-01-01

    Background Several studies suggest an increase of oxidative stress and a reduction of endothelial function in obstructive sleep apnoea syndrome (OSAS). We assessed the association between OSAS, endothelial dysfunction and oxidative stress. Further aim was to evaluate the effect of nasal continuous positive airway pressure (nCPAP) on oxidative stress and arterial dysfunction. Methods We studied 138 consecutive patients with heavy snoring and possible OSAS. Patients underwent unattended overnight home polysomnography. Ten patients with severe OSAS were revaluated after 6 months of nCPAP therapy. To assess oxidative stress in vivo, we measured urinary 8-iso-PGF2α and serum levels of soluble NOX2-derived peptide (sNOX2-dp). Serum levels of nitrite/nitrate (NOx) were also determined. Flow-mediated brachial artery dilation (FMD) was measured to asses endothelial function. Results Patients with severe OSAS had higher urinary 8-iso-PGF2α (p<0.001) and serum NOX2 and lower NOx. A negative association was observed between FMD and OSA severity. Apnea/hypopnea index was significantly correlated with the indices of central obesity and with urinary 8-isoprostanes (r=0.298, p<0.001). The metabolic syndrome (t=-4.63, p<0.001) and urinary 8-isoprostanes (t=-2.02, p<0.05) were the only independent predictors of FMD. After 6-months nCPAP treatment, a significant decrease of serum NOX2, (p<0.005) and urinary 8-iso-PGF2α (p<0.01) was observed, while serum NOx showed only a minor increase. A statistically significant increase of FMD was observed (from 3.6% to 7.0%). Conclusions The results of our study indicate that patients with OSAS and cardiometabolic comorbidities have increased oxidative stress and arterial dysfunction that are partially reversed by nCPAP treatment. PMID:22824065

  9. Predicting CPAP Use and Treatment Outcomes Using Composite Indices of Sleep Apnea Severity

    PubMed Central

    Balakrishnan, Karthik; James, Kathryn T.; Weaver, Edward M.

    2016-01-01

    Study Objectives: Measures of baseline sleep apnea disease burden (apnea-hypopnea index, Epworth Sleepiness Scale) predict continuous positive airway pressure (CPAP) adherence, but composite indices of sleep apnea severity (Sleep Apnea Severity Index, Modified Sleep Apnea Severity Index) may be more robust measures of disease burden. We tested the relative prognostic ability of each measure of sleep apnea disease burden to predict subsequent CPAP adherence and subjective sleep outcomes. Methods: Prospective cohort study at a tertiary academic sleep center. Patients (n = 323) underwent initial diagnostic polysomnography for suspected obstructive sleep apnea and 6 mo of subsequent CPAP therapy Results: Baseline apnea-hypopnea index and both composite indices predicted adherence to CPAP therapy at 6 mo in multivariate analyses (all p ≤ 0.001). Baseline Epworth Sleepiness Scale did not predict CPAP adherence (p = 0.22). Both composite indices were statistically stronger predictors of CPAP adherence at 6 mo than apnea-hypopnea index (p < 0.001). In multivariate analyses, baseline apnea-hypopnea index (p < 0.05) and both composite indices (both p < 0.04) predicted change in Pittsburgh Sleep Quality Index, whereas only the composite indices predicted changes in Sleep Apnea Quality of Life Index (both p < 0.001). Adjustment for treatment adherence did not affect the relationship of the composite indices with change in Sleep Apnea Quality of Life Index (both p ≤ 0.005). Conclusions: Composite indices of baseline sleep apnea severity better predict objective CPAP adherence and subjective treatment outcomes than baseline apnea-hypopnea index and baseline Epworth Sleepiness Scale. Citation: Balakrishnan K, James KT, Weaver EM. Predicting CPAP use and treatment outcomes using composite indices of sleep apnea severity. J Clin Sleep Med 2016;12(6):849–854. PMID:26857052

  10. Effect of CPAP treatment on endothelial function and plasma CRP levels in patients with sleep apnea

    PubMed Central

    Panoutsopoulos, Athanasios; Kallianos, Anastasios; Kostopoulos, Konstantinos; Seretis, Charalampos; Koufogiorga, Eleni; Protogerou, Athanasios; Trakada, Georgia; Kostopoulos, Charalampos; Zakopoulos, Nikolaos; Nikolopoulos, Ioannis

    2012-01-01

    Summary Background Continuous positive airway pressure (CPAP) is the most effective method for treating obstructive sleep apnea syndrome (OSAS) and alleviating symptoms. Improved sleep quality with effective CPAP therapy might also contribute to attenuated systemic inflammation and improved endothelial function, with subsequent reduction of cardiovascular risk. The aim of this study was to assess the effect of 3-month CPAP therapy on brachial artery flow-mediated dilation (FMD) and plasma C-reactive protein (CRP) levels in patients with OSAS. Material/Methods Our study group consisted of 38 male patients with no prior history of cardiovascular disease. Twenty patients with an Apnea-Hypopnea Index (AHI) ≥15 were assigned to receive CPAP treatment and 18 subjects with an AHI<5 were included in the control group. Six patients failed to comply with the CPAP treatment. Measurement of FMD and blood analysis was performed at baseline and 3 months after CPAP therapy. Results Baseline FMD values were negatively correlated with age, BMI, AHI, DSI,% of time <90% Sa02, and CRP (p<0.05). Plasma CRP values were positively correlated with BMI, AHI, DSI and% of time <90% Sa02 (p<0.05). In the group of patients who complied with the CPAP treatment, there was a significant increase in the FMD values (9.18±0.55 vs. 6.27±0.50) and a decrease in the levels of CRP (0.67±0.15 vs. 0.84±0.18) (p<0.05). Conclusions Appropriate CPAP therapy improved both CRP and FMD values, suggesting its potentially beneficial role in reducing cardiovascular risk in OSAS patients. PMID:23197238

  11. A Randomized Trial Comparing Efficacy of Bubble and Ventilator Derived Nasal CPAP in Very Low Birth Weight Neonates with Respiratory Distress

    PubMed Central

    Agarwal, Sheetal; Roy, Mahesh K.; Verma, Ankit

    2016-01-01

    Introduction Continuous Positive Airway Pressure (CPAP) has an established role in the care of Very Low Birth Weight (VLBW) babies with respiratory distress. Bubble CPAP (BCPAP) is a cheap alternative for countries where resources are limited. However, data comparing efficacy of BCPAP with conventional ventilator derived (VCPAP) is limited. Aim To compare CPAP failure rates between BCPAP and VCPAP among VLBW, with moderate respiratory distress. Secondary objectives were to compare the rates of Intraventricular Haemorrhage (IVH), pulmonary air leaks and deaths between the two groups and determine the predictors of CPAP failure. Materials and Methods VLBW babies with moderate respiratory distress (Silverman Anderson score 4-7), born or admitted in Neonatal Intensive Care Unit (NICU) within 28 days of life were randomized to receive either BCPAP (n=34) or VCPAP (n=34). CPAP failure rate in both the groups was compared. Results The baseline characteristics were similar in both the groups. Five out of 34 (14.70%) babies in BCPAP group and 11 out of 34 (32.35%) in VCPAP failed CPAP (p=0.08). IVH (BCPAP group 24% and VCPAP group 9%, p= 0.10) and mortality (BCPAP group 6% and VCPAP group 9%, p=0.642) were comparable in both the groups. Factors such as gestational age <30 weeks, weight <1000 grams, Respiratory Distress Syndrome (RDS), shock, pulmonary haemorrhage, Disseminated Intravascular Coagulation (DIC) and multi-organ dysfunction were significantly associated with CPAP failure in our study. Conclusion The CPAP failure rates in VLBW babies with moderate respiratory distress were found to be similar whether bubble CPAP or ventilator CPAP was used. There was no difference in complication rates of IVH or mortality with either method of CPAP. PMID:27790540

  12. Retrospective, nonrandomized controlled study on autoadjusting, dual-pressure positive airway pressure therapy for a consecutive series of complex insomnia disorder patients

    PubMed Central

    Krakow, Barry; McIver, Natalia D; Ulibarri, Victor A; Nadorff, Michael R

    2017-01-01

    Purpose Emerging evidence shows that positive airway pressure (PAP) treatment of obstructive sleep apnea (OSA) and upper airway resistance syndrome (UARS) in chronic insomnia patients (proposed “complex insomnia” disorder) leads to substantial decreases in insomnia severity. Although continuous PAP (CPAP) is the pressure mode most widely researched, intolerance to fixed pressurized air is rarely investigated or described in comorbidity patients. This retrospective study examined dual pressure, autoadjusting PAP modes in chronic, complex insomnia disorder patients. Patients and methods Chronic insomnia disorder patients (mean [SD] insomnia severity index [ISI] =19.11 [3.34]) objectively diagnosed with OSA or UARS and using either autobilevel PAP device or adaptive servoventilation (ASV) device after failing CPAP therapy (frequently due to intolerance to pressurized air, poor outcomes, or emergence of CSA) were divided into PAP users (≥20 h/wk) and partial users (<20 h/wk) for comparison. Subjective and objective baseline and follow-up measures were analyzed. Results Of the 302 complex insomnia patients, PAP users (n=246) averaged 6.10 (1.78) nightly hours and 42.71 (12.48) weekly hours and partial users (n=56) averaged 1.67 (0.76) nightly hours and 11.70 (5.31) weekly hours. For mean (SD) decreases in total ISI scores, a significant (group × time) interaction was observed (F[1,300]=13.566; P<0.0001) with PAP users (–7.59 [5.92]; d=1.63) showing superior results to partial users (−4.34 [6.13]; d=0.81). Anecdotally, patients reported better tolerability with advanced PAP compared to previous experience with CPAP. Both adaptive servoventilation and autobilevel PAP showed similar ISI score improvement without statistical differences between devices. Total weekly hours of PAP use correlated inversely with change in insomnia symptoms (r=−0.256, P<0.01). Conclusion Insomnia severity significantly decreased in patients using autoadjusting PAP devices, but the

  13. Effect of CPAP Therapy in Improving Daytime Sleepiness in Indian Patients with Moderate and Severe OSA

    PubMed Central

    Battan, Gulshan; Panwar, Ajay; Atam, Virendra; Kumar, Pradeep; Gangwar, Anil; Roy, Ujjawal

    2016-01-01

    Introduction Obstructive Sleep Apnoea (OSA) is a highly prevalent disease and a major public health issue in India. Excessive daytime sleepiness is an almost ubiquitous symptom of OSA. Epworth Sleepiness Scale (ESS) score is a validated objective score to measure the degree of daytime sleepiness. Continuous Positive Airway Pressure (CPAP) therapy has been established as the gold standard treatment modality for OSA patients. A few Indian studies have reported the effectiveness of CPAP therapy in improving ESS scores after 1st month of CPAP use. Aim To observe both, short-term (one month) and long-term (three month) effects of CPAP therapy on ESS scores in moderate to severe OSA patients. Materials and Methods The patients complaining of excessive day-time sleepiness, snoring and choking episodes during sleep, consecutively presenting to medicine OPD over a period of 2 years, were subjected to Polysomnography (PSG). Seventy-three patients with apnoea-hypopnea index (AHI) ≥15 were categorised as having moderate to severe forms of OSA (moderate OSA with AHI=15-30 and severe OSA with AHI >30), and were scheduled for an initial trial of CPAP therapy. Forty-seven patients reported good tolerance to CPAP therapy after a trial period of 2 weeks and comprised the final study group. ESS scores in these patients were recorded at the baseline, and after 1st and 3rd month of CPAP therapy, and statistically analysed for significance. Results Mean ESS score at the baseline among moderate and severe OSA patients were 13.67±2.29 and 16.56 ±1.87, respectively. ESS score in both these subgroups improved significantly to 11.63±3.79, p=0.022, CI (0.3293-4.0106)} and 14.13 ±3.74, p < 0.001, CI (1.2991-4.5408), respectively after one month of CPAP therapy. Likewise, mean ESS scores among moderate and severe OSA patients improved significantly to 9.84 ±2.97, p = 0.022, CI (0.3293-4.0106) and 12.29 ±3.97, p <0.001, CI (2.9414-6.1385), respectively after three months of CPAP therapy

  14. Sleep Apnea Related Risk of Motor Vehicle Accidents is Reduced by Continuous Positive Airway Pressure: Swedish Traffic Accident Registry Data

    PubMed Central

    Karimi, Mahssa; Hedner, Jan; Häbel, Henrike; Nerman, Olle; Grote, Ludger

    2015-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is associated with an increased risk of motor vehicle accidents (MVAs). The rate of MVAs in patients suspected of having OSA was determined and the effect of continuous positive airway pressure (CPAP) was investigated. Design: MVA rate in patients referred for OSA was compared to the rate in the general population using data from the Swedish Traffic Accident Registry (STRADA), stratified for age and calendar year. The risk factors for MVAs, using demographic and polygraphy data, and MVA rate before and after CPAP were evaluated in the patient group. Setting: Clinical sleep laboratory and population based control (n = 635,786). Patients: There were 1,478 patients, male sex 70.4%, mean age 53.6 (12.8) y. Interventions: CPAP. Measurements and Results: The number of accidents (n = 74) among patients was compared with the expected number (n = 30) from a control population (STRADA). An increased MVA risk ratio of 2.45 was found among patients compared with controls (P < 0.001). Estimated excess accident risk was most prominent in the elderly patients (65–80 y, seven versus two MVAs). In patients, driving distance (km/y), EDS (Epworth Sleepiness score ≥ 16), short habitual sleep time (≤ 5 h/night), and use of hypnotics were associated with increased MVA risk (odds ratios 1.2, 2.1, 2.7 and 2.1, all P ≤ 0.03). CPAP use ≥ 4 h/night was associated with a reduction of MVA incidence (7.6 to 2.5 accidents/1,000 drivers/y). Conclusions: The motor vehicle accident risk in this large cohort of unselected patients with obstructive sleep apnea suggests a need for accurate tools to identify individuals at risk. Sleep apnea severity (e.g., apnea-hypopnea index) failed to identify patients at risk. Citation: Karimi M, Hedner J, Häbel H, Nerman O, Grote L. Sleep apnea related risk of motor vehicle accidents is reduced by continuous positive airway pressure: Swedish traffic accident registry data. SLEEP 2015;38(3):341–349. PMID

  15. Humidified High Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure as an Initial Respiratory Support in Preterm Infants with Respiratory Distress: a Randomized, Controlled Non-Inferiority Trial.

    PubMed

    Shin, Jeonghee; Park, Kyuhee; Lee, Eun Hee; Choi, Byung Min

    2017-04-01

    Heated, humidified, high-flow nasal cannula (HHFNC) is frequently used as a noninvasive respiratory support for preterm infants with respiratory distress. But there are limited studies that compares HHFNC with nasal continuous positive airway pressure (nCPAP) only as the initial treatment of respiratory distress in preterm infants immediately after birth. The aim of this study is to assess the effectiveness and safety of HHFNC compared to nCPAP for the initial treatment of preterm infants with respiratory distress. Preterm infants at between 30 and 35 weeks of gestational age were randomized to HHFNC or nCPAP when they showed respiratory distress in less than 24 hours of age postnatally. Preterm infants who needed invasive respiratory supports were excluded. Primary outcome was the incidence of treatment failure (defined as need for the intubation or mechanical ventilation). Eighty-five infants were analyzed. Sixteen of 42 infants randomized to HHFNC showed treatment failure compared to 9 of 43 infants using nCPAP (Risk difference 17.17 [-1.90-36.23]; P = 0.099). In terms of the reason for treatment failure, the frequency of hypoxia was significantly higher in the HHFNC group than in the nCPAP group (P = 0.020). There was no difference between the 2 groups in terms of respiratory and clinical outcomes and complications. Although HHFNC is safe compared to nCPAP, it is not certain that HHFNC is effective compared to nCPAP non-inferiorly as an initial respiratory support in preterm infants with respiratory distress.

  16. Humidified High Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure as an Initial Respiratory Support in Preterm Infants with Respiratory Distress: a Randomized, Controlled Non-Inferiority Trial

    PubMed Central

    2017-01-01

    Heated, humidified, high-flow nasal cannula (HHFNC) is frequently used as a noninvasive respiratory support for preterm infants with respiratory distress. But there are limited studies that compares HHFNC with nasal continuous positive airway pressure (nCPAP) only as the initial treatment of respiratory distress in preterm infants immediately after birth. The aim of this study is to assess the effectiveness and safety of HHFNC compared to nCPAP for the initial treatment of preterm infants with respiratory distress. Preterm infants at between 30 and 35 weeks of gestational age were randomized to HHFNC or nCPAP when they showed respiratory distress in less than 24 hours of age postnatally. Preterm infants who needed invasive respiratory supports were excluded. Primary outcome was the incidence of treatment failure (defined as need for the intubation or mechanical ventilation). Eighty-five infants were analyzed. Sixteen of 42 infants randomized to HHFNC showed treatment failure compared to 9 of 43 infants using nCPAP (Risk difference 17.17 [−1.90–36.23]; P = 0.099). In terms of the reason for treatment failure, the frequency of hypoxia was significantly higher in the HHFNC group than in the nCPAP group (P = 0.020). There was no difference between the 2 groups in terms of respiratory and clinical outcomes and complications. Although HHFNC is safe compared to nCPAP, it is not certain that HHFNC is effective compared to nCPAP non-inferiorly as an initial respiratory support in preterm infants with respiratory distress. PMID:28244292

  17. Randomised controlled comparison of continuous positive airways pressure, bilevel non-invasive ventilation, and standard treatment in emergency department patients with acute cardiogenic pulmonary oedema

    PubMed Central

    Crane, S; Elliott, M; Gilligan, P; Richards, K; Gray, A

    2004-01-01

    Background: Continuous positive airways pressure (CPAP) and bilevel non-invasive ventilation may have beneficial effects in the treatment of patients with acute cardiogenic pulmonary oedema. The efficacy of both treatments was assessed in the UK emergency department setting, in a randomised comparison with standard oxygen therapy. Methods: Sixty patients presenting with acidotic (pH<7.35) acute, cardiogenic pulmonary oedema, were randomly assigned conventional oxygen therapy, CPAP (10 cm H2O), or bilevel ventilation (IPAP 15 cm H2O, EPAP 5 cm H2O) provided by a standard ventilator through a face mask. The main end points were treatment success at two hours and in-hospital mortality. Analyses were by intention to treat. Results: Treatment success (defined as all of respiratory rate<23 bpm, oxygen saturation of>90%, and arterial blood pH>7.35 (that is, reversal of acidosis), at the end of the two hour study period) occurred in three (15%) patients in the control group, seven (35%) in the CPAP group, and nine (45%) in the bilevel group (p = 0.116). Fourteen (70%) of the control group patients survived to hospital discharge, compared with 20 (100%) in the CPAP group and 15 (75%) in the bilevel group (p = 0.029; Fisher's test). Conclusions: In this study, patients presenting with acute cardiogenic pulmonary oedema and acidosis, were more likely to survive to hospital discharge if treated with CPAP, rather than with bilevel ventilation or with conventional oxygen therapy. There was no relation between in hospital survival and early physiological changes. Survival rates were similar to other studies despite a low rate of endotracheal intubation. PMID:14988338

  18. Airway pressure with chest compressions versus Heimlich manoeuvre in recently dead adults with complete airway obstruction.

    PubMed

    Langhelle, A; Sunde, K; Wik, L; Steen, P A

    2000-04-01

    In a previous case report a standard chest compression successfully removed a foreign body from the airway after the Heimlich manoeuvre had failed. Based on this case, standard chest compressions and Heimlich manoeuvres were performed by emergency physicians on 12 unselected cadavers with a simulated complete airway obstruction in a randomised crossover design. The mean peak airway pressure was significantly lower with abdominal thrusts compared to chest compressions, 26.4+/-19.8 cmH(2)O versus 40.8+/-16.4 cmH(2)O, respectively (P=0.005, 95% confidence interval for the mean difference 5.3-23.4 cmH(2)O). Standard chest compressions therefore have the potential of being more effective than the Heimlich manoeuvre for the management of complete airway obstruction by a foreign body in an unconscious patient. Removal of the Heimlich manoeuvre from the resuscitation algorithm for unconscious patients with suspected airway obstruction will also simplify training.

  19. Clinical review: Biphasic positive airway pressure and airway pressure release ventilation

    PubMed Central

    Putensen, Christian; Wrigge, Hermann

    2004-01-01

    This review focuses on mechanical ventilation strategies that allow unsupported spontaneous breathing activity in any phase of the ventilatory cycle. By allowing patients with the acute respiratory distress syndrome to breathe spontaneously, one can expect improvements in gas exchange and systemic blood flow, based on findings from both experimental and clinical trials. In addition, by increasing end-expiratory lung volume, as occurs when using biphasic positive airway pressure or airway pressure release ventilation, recruitment of collapsed or consolidated lung is likely to occur, especially in juxtadiaphragmatic lung legions. Traditional approaches to mechanical ventilatory support of patients with acute respiratory distress syndrome require adaptation of the patient to the mechanical ventilator using heavy sedation and even muscle relaxation. Recent investigations have questioned the utility of sedation, muscle paralysis and mechanical control of ventilation. Furthermore, evidence exists that lowering sedation levels will decrease the duration of mechanical ventilatory support, length of stay in the intensive care unit, and overall costs of hospitalization. Based on currently available data, we suggest considering the use of techniques of mechanical ventilatory support that maintain, rather than suppress, spontaneous ventilatory effort, especially in patients with severe pulmonary dysfunction. PMID:15566621

  20. Non-invasive ventilation with bubble CPAP is feasible and improves respiratory physiology in hospitalised Malawian children with acute respiratory failure

    PubMed Central

    Walk, J.; Dinga, P.; Banda, C.; Msiska, T.; Chitsamba, E.; Chiwayula, N.; Lufesi, N.; Mlotha-Mitole, R.; Costello, A.; Phiri, A.; Colbourn, T.; McCollum, E. D.; Lang, H. J.

    2015-01-01

    Background In low-income countries and those with a high prevalence of HIV, respiratory failure is a common cause of death in children. However, the role of non-invasive ventilation with bubble continuous positive airway pressure (bCPAP) in these patients is not well established. Methods A prospective observational study of bCPAP was undertaken between July and September 2012 in 77 Malawian children aged 1 week to 14 years with progressive acute respiratory failure despite oxygen and antimicrobial therapy. Results Forty-one (53%) patients survived following bCPAP treatment, and an HIV-uninfected single-organ disease subgroup demonstrated bCPAP success in 14 of 17 (82%). Compared with children aged ≥60 months, infants of 0–2 months had a 93% lower odds of bCPAP failure (odds ratio 0.07, 95% confidence interval 0.004–1.02, P = 0.05). Following commencement of bCPAP, respiratory physiology improved, the average respiratory rate decreased from 61 to 49 breaths/minute (P = 0.0006), and mean oxygen saturation increased from 92.1% to 96.1% (P = 0.02). Conclusions bCPAP was well accepted by caregivers and patients and can be feasibly implemented into a tertiary African hospital with high-risk patients and limited resources. PMID:25434361

  1. Natriuretic Peptide and High-Sensitive Troponin T Concentrations Correlate with Effectiveness of Short-Term CPAP in Patients with Obstructive Sleep Apnea and Coronary Artery Disease

    PubMed Central

    Strehmel, Ralf; Valo, Misa; Teupe, Claudius

    2016-01-01

    The risk of cardiovascular complications is increased in patients with obstructive sleep apnea (OSA). Continuous positive airway pressure (CPAP) is the most effective way to treat clinically significant OSA. We hypothesized that the concentrations of the cardiac risk markers N-terminal brain natriuretic peptide (NT-proBNP) and high-sensitive troponin T (hs-TropT) correlate with the effectiveness of CPAP therapy in patients with OSA and coexisting coronary artery disease (CAD). Twenty-one patients with severe OSA and coexisting CAD (group 1) and 20 control patients with severe OSA alone (group 2) were treated with CPAP and monitored by laboratory-based polysomnography. NT-proBNP and hs-TropT levels were measured before and after CPAP. Apnea–hypopnea index (AHI) and oxygen desaturation were similar in both groups. In group 1, hs-TropT levels correlated with AHI and oxygen desaturation upon CPAP. Elevated NT-proBNP levels in group 1 were significantly reduced by CPAP. NT-proBNP levels correlated with AHI and showed negative correlation with ST-segment depression. No such correlations were found in group 2. CPAP has the potential to normalize elevated NT-proBNP serum levels in patients with severe OSA and coexisting CAD. Levels of NT-proBNP and hs-TropT correlated with AHI and oxygen desaturation. PMID:27980444

  2. Efficacy of a Low-Cost Bubble CPAP System in Treatment of Respiratory Distress in a Neonatal Ward in Malawi

    PubMed Central

    Kawaza, Kondwani; Machen, Heather E.; Brown, Jocelyn; Mwanza, Zondiwe; Iniguez, Suzanne; Gest, Al; Smith, E. O'Brian; Oden, Maria; Richards-Kortum, Rebecca R.; Molyneux, Elizabeth

    2014-01-01

    Background Respiratory failure is a leading cause of neonatal mortality in the developing world. Bubble continuous positive airway pressure (bCPAP) is a safe, effective intervention for infants with respiratory distress and is widely used in developed countries. Because of its high cost, bCPAP is not widely utilized in low-resource settings. We evaluated the performance of a new bCPAP system to treat severe respiratory distress in a low resource setting, comparing it to nasal oxygen therapy, the current standard of care. Methods We conducted a non-randomized convenience sample study to test the efficacy of a low-cost bCPAP system treating newborns with severe respiratory distress in the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi. Neonates weighing >1,000 g and presenting with severe respiratory distress who fulfilled inclusion criteria received nasal bCPAP if a device was available; if not, they received standard care. Clinical assessments were made during treatment and outcomes compared for the two groups. Findings 87 neonates (62 bCPAP, 25 controls) were recruited. Survival rate for neonates receiving bCPAP was 71.0% (44/62) compared with 44.0% (11/25) for controls. 65.5% (19/29) of very low birth weight neonates receiving bCPAP survived to discharge compared to 15.4% (1/13) of controls. 64.6% (31/48) of neonates with respiratory distress syndrome (RDS) receiving bCPAP survived to discharge, compared to 23.5% (4/17) of controls. 61.5% (16/26) of neonates with sepsis receiving bCPAP survived to discharge, while none of the seven neonates with sepsis in the control group survived. Interpretation Use of a low-cost bCPAP system to treat neonatal respiratory distress resulted in 27% absolute improvement in survival. The beneficial effect was greater for neonates with very low birth weight, RDS, or sepsis. Implementing appropriate bCPAP devices could reduce neonatal mortality in developing countries. PMID:24489715

  3. Effect of Continuous Positive Airway Pressure Therapy on Glycemic Excursions and Insulin Sensitivity in Patients with Obstructive Sleep Apnea-hypopnea Syndrome and Type 2 Diabetes

    PubMed Central

    Guo, Li-Xin; Zhao, Xin; Pan, Qi; Sun, Xue; Li, Hui; Wang, Xiao-Xia; Zhang, Li-Na; Wang, Yao

    2015-01-01

    Background: For patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) and type 2 diabetes mellitus (T2DM), the night sleep interruption and intermittent hypoxia due to apnea or hypopnea may induce glycemic excursions and reduce insulin sensitivity. This study aimed to investigate the effect of continuous positive airway pressure (CPAP) therapy in patients with OSAHS and T2DM. Methods: Continuous glucose monitoring system (CGMS) was used in 40 patients with T2DM and newly diagnosed OSAHS. The measurements were repeated after 30 days of CPAP treatment. Subsequently, insulin sensitivity and glycohemoglobin (HbA1c) were measured and compared to the pretreatment data. Results: After CPAP therapy, the CGMS indicators showed that the 24-h mean blood glucose (MBG) and the night time MBG were significantly reduced (P < 0.05 and P = 0.03, respectively). The mean ambulatory glucose excursions (MAGEs) and the mean of daily differences were also significantly reduced (P < 0.05 and P = 0.002, respectively) compared to pretreatment levels. During the night, MAGE also significantly decreased (P = 0.049). The differences between the highest and lowest levels of blood glucose over 24 h and during the night were significantly lower than prior to CPAP treatment (P < 0.05 and P = 0.024, respectively). The 24 h and night time durations of high blood glucose (>7.8 mmol/L and > 11.1 mmol/L) decreased (P < 0.05 and P < 0.05, respectively) after the treatment. In addition, HbA1c levels were also lower than those before treatment (P < 0.05), and the homeostasis model assessment index of insulin resistance was also significantly lower than before CPAP treatment (P = 0.034). Conclusions: CPAP therapy may have a beneficial effect on improving not only blood glucose but also upon insulin sensitivity in T2DM patients with OSAHS. This suggests that CPAP may be an effective treatment for T2DM in addition to intensive diabetes management. PMID:26315076

  4. A New Animal Model of Obstructive Sleep Apnea Responding to Continuous Positive Airway Pressure

    PubMed Central

    Neuzeret, Pierre-Charles; Gormand, Frédéric; Reix, Philippe; Parrot, Sandrine; Sastre, Jean-Pierre; Buda, Colette; Guidon, Gérard; Sakai, Kazuya; Lin, Jian-Sheng

    2011-01-01

    Study Objectives: An improved animal model of obstructive sleep apnea (OSA) is needed for the development of effective pharmacotherapies. In humans, flexion of the neck and a supine position, two main pathogenic factors during human sleep, are associated with substantially greater OSA severity. We postulated that these two factors might generate OSA in animals. Design: We developed a restraining device for conditioning to investigate the effect of the combination of 2 body positions—prone (P) or supine (S)—and 2 head positions—with the neck flexed at right angles to the body (90°) or in extension in line with the body (180°)—during sleep in 6 cats. Polysomnography was performed twice on each cat in each of the 4 sleeping positions—P180, S180, P90, or S90. The effect of continuous positive airway pressure (CPAP) treatment was then investigated in 2 cats under the most pathogenic condition. Setting: NA. Patients or Participants: NA. Interventions: NA. Measurements and Results: Positions P180 and, S90 resulted, respectively, in the lowest and highest apnea-hypopnea index (AHI) (3 ± 1 vs 25 ± 2, P < 0.001), while P90 (18 ± 3, P < 0.001) and S180 (13 ± 5, P < 0.01) gave intermediate values. In position S90, an increase in slow wave sleep stage 1 (28% ± 3% vs 22% ± 3%, P < 0.05) and a decrease in REM sleep (10% ± 2% vs 18% ± 2%, P < 0.001) were also observed. CPAP resulted in a reduction in the AHI (8 ± 1 vs 27 ± 3, P < 0.01), with the added benefit of sleep consolidation. Conclusion: By mimicking human pathogenic sleep conditions, we have developed a new reversible animal model of OSA. Citation: Neuzeret PC; Gormand F; Reix P; Parrot S; Sastre JP; Buda C; Guidon G; Sakai K; Lin JS. A new animal model of obstructive sleep apnea responding to continuous positive airway pressure. SLEEP 2011;34(4):541-548. PMID:21461333

  5. A Pilot Study on the Efficacy of Continuous Positive Airway Pressure on the Manifestations of Ménière's Disease in Patients with Concomitant Obstructive Sleep Apnea Syndrome

    PubMed Central

    Nakayama, Meiho; Masuda, Ayako; Ando, Kayoko Bhardwaj; Arima, Sachie; Kabaya, Kayoko; Inagaki, Akira; Nakamura, Yoshihisa; Suzuki, Motohiko; Brodie, Hilary; Diaz, Rodney C.; Murakami, Shingo

    2015-01-01

    Objective: To evaluate the effect of continuous positive airway pressure (CPAP) therapy on Ménière's disease patients with concomitant obstructive sleep apnea syndrome (OSAS), since recent reports suggest OSAS may cause dysfunction of the vestibular system. Study Design: Prospective study using CPAP administered to patients diagnosed with “Definite Ménière's disease” according to the guidelines of the American Academy of Otolaryngology— Head and Neck Surgery and combined with OSAS. Setting: University hospital. Methods: Twenty consecutive patients, 14 male and 6 female with active, unilateral, cochleovestibular Ménière's disease refractory to medical management who also had concurrent OSAS as defined by International Classification of Sleep Disorders, Second Edition were selected to undergo solitary CPAP therapy. Audiometric testing, caloric testing, and DHI survey were conducted before and after CPAP therapy and compared to assess effectiveness of CPAP therapy as utilized for treatment of Ménière's disease. Results: Although caloric testing did not show significant difference, audiometric testing and results of dizziness handicap inventory were significantly improved (p < 0.05) after CPAP therapy only, without standard treatment for Ménière's disease. Conclusions: Recent reports have suggested that OSAS may cause dysfunction of the vestibular system. We investigated whether standard therapy for OSAS would be of benefit in the management of vertigo and hearing loss in Ménière's disease patients. Our study cohort demonstrated significant improvement in both DHI and audiometric testing following solitary CPAP therapy for OSAS. Solitary CPAP therapy may become a new effective treatment strategy for Ménière's disease patients with OSAS, not just only for control of dizziness and vertigo but also for potential benefit of hearing. Citation: Nakayama M, Masuda A, Ando KB, Arima S, Kabaya K, Inagaki A, Nakamura Y, Suzuki M, Brodie H, Diaz RC, Murakami S

  6. Use of Bioimpedance to Assess Changes in Hemodynamics During Acute Administration of CPAP

    PubMed Central

    Digby, Genevieve C.; Driver, Helen S.; Fitzpatrick, Michael; Ropchan, Glorianne; Parker, Christopher M.

    2011-01-01

    Background Attempts to investigate the mechanisms by which continuous positive airway pressure (CPAP) therapy improves heart function in patients with obstructive sleep apnea (OSA) have been limited by the lack of non-invasive methods to assess cardiac performance. We used transthoracic electrical bioimpedance (TEB) to assess acute hemodynamic changes including heart rate (HR), stroke volume (SV), cardiac output (CO) and cardiac index (CI) during PAP titration in (1) post-operative cardiac surgery patients, (2) patients with severe OSA, and (3) normal healthy volunteers. Methods Post-operative cardiac surgery patients were studied via TEB and pulmonary artery catheter (PAC) during acute titration of positive end-expiratory pressure (PEEP) while mechanically ventilated. Patients with severe OSA were studied non-invasively by TEB during acute CPAP titration in supine stage 2 sleep, and normal subjects while awake and recumbent. Results In post-operative cardiac surgery patients (n = 3), increasing PEEP to 18 cmH2O significantly reduced SV and CI relative to baseline. There was no difference between TEB and PAC in terms of ability to assess variations in hemodynamic parameters. In patients with severe OSA (n = 3), CPAP titration to optimal pressure to alleviate obstructive apneas reduced HR, SV, CO and CI significantly compared to without CPAP. In three healthy subjects, maximal tolerated CPAP reduced SV and CO significantly compared to baseline. Conclusions Acute administration of CPAP causes a decrease in CO and CI, apparently a consequence of a reduction in SV. TEB appears to be an accurate and reproducible non-invasive method of detecting changes in hemodynamics.

  7. Detection of Upper Airway Status and Respiratory Events by a Current Generation Positive Airway Pressure Device

    PubMed Central

    Li, Qing Yun; Berry, Richard B.; Goetting, Mark G.; Staley, Bethany; Soto-Calderon, Haideliza; Tsai, Sheila C.; Jasko, Jeffrey G.; Pack, Allan I.; Kuna, Samuel T.

    2015-01-01

    Study Objectives: To compare a positive airway pressure (PAP) device's detection of respiratory events and airway status during device-detected apneas with events scored on simultaneous polysomnography (PSG). Design: Prospective PSGs of patients with sleep apnea using a new-generation PAP device. Settings: Four clinical and academic sleep centers. Patients: Forty-five patients with obstructive sleep apnea (OSA) and complex sleep apnea (Comp SA) performed a PSG on PAP levels adjusted to induce respiratory events. Interventions: None. Measurements and Results: PAP device data identifying the type of respiratory event and whether the airway during a device-detected apnea was open or obstructed were compared to time-synced, manually scored respiratory events on simultaneous PSG recording. Intraclass correlation coefficients between device-detected and PSG scored events were 0.854 for apnea-hypopnea index (AHI), 0.783 for apnea index, 0.252 for hypopnea index, and 0.098 for respiratory event-related arousals index. At a device AHI (AHIFlow) of 10 events/h, area under the receiver operating characteristic curve was 0.98, with sensitivity 0.92 and specificity 0.84. AHIFlow tended to overestimate AHI on PSG at values less than 10 events/h. The device detected that the airway was obstructed in 87.4% of manually scored obstructive apneas. Of the device-detected apneas with clear airway, a minority (15.8%) were manually scored as obstructive apneas. Conclusions: A device-detected apnea-hypopnea index (AHIFlow) < 10 events/h on a positive airway pressure device is strong evidence of good treatment efficacy. Device-detected airway status agrees closely with the presumed airway status during polysomnography scored events, but should not be equated with a specific type of respiratory event. Citation: Li QY, Berry RB, Goetting MG, Staley B, Soto-Calderon H, Tsai SC, Jasko JG, Pack AI, Kuna ST. Detection of upper airway status and respiratory events by a current generation positive

  8. Effects of continuous negative airway pressure-related lung deflation on upper airway collapsibility.

    PubMed

    Sériès, F; Marc, I

    1993-09-01

    Continuous negative airway pressure (CNAP) causes a decrease in lung volume, which is known to increase upper airway resistance by itself. We studied how this lung volume change could modify upper airway collapsibility with five normal awake subjects. In a first trial, pressure in a nasal mask (Pm) was progressively decreased in 3- to 5-cmH2O steps (CNAP). In a second trial, changes in lung volumes resulting from CNAP were prevented by applying simultaneously an equivalent level of negative extrathoracic pressure into a poncho-type respirator [isovolumetric CNAP (CNAPisovol)]. For each trial, we examined the relationship between the maximal inspiratory airflow of each flow-limited inspiratory cycle and the corresponding Pm by least-squares linear regression analysis and determined the critical pressure. We also determined the Pm threshold corresponding to the first Pm value below which flow limitation occurred. Flow limitation was observed in each subject with CNAP but in only two subjects with CNAPisovol. In these two subjects, the Pm threshold values were -20 and -9 cmH2O with CNAP and -39 and -16 cmH2O with CNAPisovol, respectively. Critical pressures for the same two subjects were -161 and -96 cmH2O with CNAP and -202 and -197 cmH2O with CNAPisovol, respectively. We conclude that CNAP-induced decreases in lung volume increase upper airway collapsibility.

  9. A randomised trial of peri-operative positive airway pressure for postoperative delirium in patients at risk for obstructive sleep apnoea after regional anaesthesia with sedation or general anaesthesia for joint arthroplasty.

    PubMed

    Nadler, J W; Evans, J L; Fang, E; Preud'Homme, X A; Daughtry, R L; Chapman, J B; Bolognesi, M P; Attarian, D E; Wellman, S S; Krystal, A D

    2017-03-02

    Previous pilot work has established an association between obstructive sleep apnoea and the development of acute postoperative delirium , but it remains unclear to what extent this risk factor is modifiable in the 'real world' peri-operative setting. In a single-blind randomised controlled trial, 135 elderly surgical patients at risk for obstructive sleep apnoea were randomly assigned to receive peri-operative continuous positive airway pressure (CPAP) or routine care. Of the 114 patients who completed the study, 21 (18.4%) experienced delirium. Delirium was equally common in both groups: 21% (12 of 58 subjects) in the CPAP group and 16% (9 of 56 subjects) in the routine care group (OR = 1.36 [95%CI 0.52-3.54], p = 0.53). Delirious subjects were slightly older - mean (SD) age 68.9 (10.7) vs. 64.9 (8.2), p = 0.07 - but had nearly identical pre-operative STOP-Bang scores (4.19 (1.1) versus 4.27 (1.3), p = 0.79). Subjects in the CPAP group used their devices for a median (IQR [range]) of 3 (0.25-5 [0-12]) nights pre-operatively (2.9 (0.1-4.8 [0.0-12.7]) hours per night) and 1 (0-2 [0-2]) nights postoperatively (1.4 (0.0-5.1 [0.0-11.6]) hours per night). Among the CPAP subjects, the residual pre-operative apnoea-hypopnea index had a significant effect on delirium severity (p = 0.0002). Although we confirm that apnoea is associated with postoperative delirium, we did not find that providing a short-course of auto-titrating CPAP affected its likelihood or severity. Voluntary adherence to CPAP is particularly poor during the initiation of therapy.

  10. Positive Airway Pressure-Induced Conversion of Atrial Fibrillation to Normal Sinus Rhythm in Severe Obstructive Sleep Apnea

    PubMed Central

    Walia, Harneet K.; Chung, Mina K.; Ibrahim, Sally; Mehra, Reena

    2016-01-01

    Accumulating data implicate obstructive sleep apnea (OSA) as a predisposing factor to the development of atrial fibrillation (AF), the latter representing the most common sustained cardiac arrhythmia. The postulated mechanisms leading to atrial arrhythmogenesis in OSA include alterations in intrathoracic pressures, intermittent hypoxemia, and autonomic nervous system fluctuations. Although these OSA-related pathophysiologic pathways may result in atrial structural and electrical remodeling, thereby predisposing to AF, there are data to suggest that the immediate influences of respiratory events may trigger arrhythmic events. This case demonstrates an immediate reversal of AF to normal sinus rhythm with optimal continuous positive airway pressure (CPAP) therapy in the background of severe OSA. These findings of immediate benefit of reversal of OSA pathophysiology on cardiac arrhythmia suggest OSA may have acute influences on cardiac electrophysiology. Citation: Walia HK, Chung MK, Ibrahim S, Mehra R. Positive airway pressure-induced conversion of atrial fibrillation to normal sinus rhythm in severe obstructive sleep apnea. J Clin Sleep Med 2016;12(9):1301–1303. PMID:27166298

  11. Decreased plasma levels of nitric oxide derivatives in obstructive sleep apnoea: response to CPAP therapy

    PubMed Central

    Schulz, R; Schmidt, D; Blum, A; Lopes-Ribeiro, X; Lucke, C; Mayer, K; Olschewski, H; Seeger, W; Grimminger, F

    2000-01-01

    BACKGROUND—Reduced endothelium dependent vasodilation has been reported in patients with obstructive sleep apnoea (OSA) but direct measurements of the most potent naturally occurring vasodilator, nitric oxide (NO) or its derivatives (nitrate and nitrite, NOx), have not yet been performed in these patients.
METHODS—In 21 patients with OSA of mean (SE) age 54 (2) years, body mass index (BMI) 30.9 (1.1) kg/m2, and apnoea-hypopnoea index (AHI) 37 (4)/h, NOx levels were measured in peripheral venous blood samples by chemiluminescence. Blood samples were obtained before and after two nights of continuous positive airway pressure (CPAP) and after 5.5 (1.5) months of follow up. Thirteen age matched, healthy volunteers and 18 patients without OSA but with a similar spectrum of comorbidity served as controls (control groups 1 and 2).
RESULTS—Before CPAP NOx levels were 21.7 (1.5) µM in patients with OSA compared with 42.6 (2.2) µM and 36.7 (1.7) µM in control groups 1 and 2, respectively (p<0.01 for each comparison). NOx concentrations increased to 32.1 (2.7) µM after two nights of CPAP and remained constant at 32.9 (2.3) µM at follow up (p<0.01 compared with levels before CPAP).
CONCLUSIONS—Plasma NOx levels are reduced in OSA and can be increased by short and long term CPAP therapy. Although the precise mechanism underlying this observation remains to be clarified, it may have important implications for the development of cardiovascular disease in patients with OSA and for the life saving effect of CPAP.

 PMID:11083891

  12. Erectile Dysfunction and Sexual Hormone Levels in Men With Obstructive Sleep Apnea: Efficacy of Continuous Positive Airway Pressure.

    PubMed

    Zhang, Xiao-Bin; Lin, Qi-Chang; Zeng, Hui-Qing; Jiang, Xing-Tang; Chen, Bo; Chen, Xiao

    2016-01-01

    In this study, the prevalence of erectile dysfunction (ED) and serum sexual hormone levels were evaluated in men with obstructive sleep apnea (OSA). In these patients, the efficacy of continuous positive airway pressure (CPAP) was determined. The 207 men (mean age 44.0 ± 11.1 years) enrolled in the study were stratified within four groups based on their apnea-hypopnea index score: simple snoring (n = 32), mild OSA (n = 29), moderate OSA (n = 38), and severe OSA (n = 108). The International Index of Erectile Dysfunction-5 (IIEF-5) score was obtained from each patient, and blood samples for the analysis of sexual hormones (prolactin, luteotropin, follicle-stimulating hormone, estradiol, progestin, and testosterone) were drawn in the morning after polysomnography. The IIEF-5 test and serum sexual hormone measurements were repeated after 3 months of CPAP treatment in 53 men with severe OSA. The prevalence of ED was 60.6 % in OSA patients overall and 72.2 % in those with severe OSA. Compared with the simple snoring group, patients with severe OSA had significantly lower testosterone levels (14.06 ± 5.62 vs. 17.02 ± 4.68, p = .018) and lower IIEF-5 scores (16.33 ± 6.50 vs. 24.09 ± 1.94, p = .001). The differences in the other sexual hormones between groups were not significant. After 3 months of CPAP treatment, there were no significant changes in sexual hormone levels, but the IIEF-5 score had improved significantly (18.21 ± 4.05 vs. 19.21 ± 3.86, p = .001). Severe OSA patients have low testosterone concentration and high ED prevalence. IIEF-5 scores increased significantly after CPAP treatment, but there was no effect on serum testosterone levels.

  13. Filters Reduce the Risk of Bacterial Transmission from Contaminated Heated Humidifiers Used with CPAP for Obstructive Sleep Apnea

    PubMed Central

    Ortolano, Girolamo A.; Schaffer, Jeffrey; McAlister, Morven B.; Stanchfield, Ilia; Hill, Elizabeth; Vandenburgh, Liliana; Lewis, Michelle; John, Shirnett; Canonica, Francis P.; Cervia, Joseph S.

    2007-01-01

    Rationale: The treatment of choice for obstructive sleep apnea (OSA) is nasal continuous positive airway pressure (nCPAP) during sleep, but dryness of the upper airway compromises compliance. Heated humidifiers may mitigate such noncompliance; however, recent observations suggest that their use, particularly if not cleaned, increases the risk of respiratory infections. Humidifier water may be contaminated, but the long-held view that passive humidifiers cannot aerosolize water may obscure the perception of risk of infection. Objectives: This study challenges the long-held view that “passover” humidifiers do not aerosolize water. With such evidence, this study characterizes the performance of filters to reduce the potential risk of contamination. Methods: Heated humidifier water contaminated with bacteria was studied under conditions simulating week-long use of nCPAP for OSA. Results: Bacteria were recovered in 9 of 11 tests from the breathing tubes of CPAP devices fitted with heated humidifiers with water contaminated with Brevundimonas diminuta or Serratia marcescens. Recoverable bacteria ranged from tens to thousands of colony forming units when tested at air flow rates of 60 liters per minute for 90 minutes. Neither organism was recovered from the circuit tubing when a hydrophobic breathing-circuit filter was positioned between the humidifier and face-mask tubing with a commercially available nCPAP machine tested under simulated-use conditions. Conclusion: Data suggest that patients with OSA being treated with nCPAP fitted with humidifiers may be aerosolizing bacteria, putting them at risk for developing respiratory infections and that the use of a hydrophobic filter may attenuate the passage of microbes from contaminated humidifier water. Citation: Ortolano GA; Schaffer J; McAlister MB et al. Filters reduce the risk of bacterial transmission from contaminated heated humidifiers used with CPAP for obstructive sleep apnea. J Clin Sleep Med 2007;3(7):700–705

  14. Brain stem activity changes associated with restored sympathetic drive following CPAP treatment in OSA subjects: a longitudinal investigation.

    PubMed

    Lundblad, Linda C; Fatouleh, Rania H; McKenzie, David K; Macefield, Vaughan G; Henderson, Luke A

    2015-08-01

    Obstructive sleep apnea (OSA) is associated with significantly elevated muscle sympathetic nerve activity (MSNA), leading to hypertension and increased cardiovascular morbidity. Although little is known about the mechanisms responsible for the sympathoexcitation, we have recently shown that the elevated MSNA in OSA is associated with altered neural processing in various brain stem sites, including the dorsolateral pons, rostral ventrolateral medulla, medullary raphe, and midbrain. Given the risk associated with elevated MSNA, we aimed to determine if treatment of OSA with continuous positive airway pressure (CPAP) would reduce the elevated MSNA and reverse the brain stem functional changes associated with the elevated MSNA. We performed concurrent recordings of MSNA and blood oxygen level-dependent (BOLD) signal intensity of the brain stem, using high-resolution functional magnetic resonance imaging, in 15 controls and 13 subjects with OSA, before and after 6 mo CPAP treatment. As expected, 6 mo of CPAP treatment significantly reduced MSNA in subjects with OSA, from 54 ± 4 to 23 ± 3 bursts/min and from 77 ± 7 to 36 ± 3 bursts/100 heart beats. Importantly, we found that MSNA-coupled changes in BOLD signal intensity within the dorsolateral pons, medullary raphe, and rostral ventrolateral medulla returned to control levels. That is, CPAP treatment completely reversed brain stem functional changes associated with elevated MSNA in untreated OSA subjects. These data highlight the effectiveness of CPAP treatment in reducing one of the most significant health issues associated with OSA, that is, elevated MSNA and its associated elevated morbidity.

  15. Impact of Acetazolamide and CPAP on Cortical Activity in Obstructive Sleep Apnea Patients

    PubMed Central

    Stadelmann, Katrin; Latshang, Tsogyal D.; Nussbaumer-Ochsner, Yvonne; Tarokh, Leila; Ulrich, Silvia; Kohler, Malcolm; Bloch, Konrad E.; Achermann, Peter

    2014-01-01

    Study Objectives 1) To investigate the impact of acetazolamide, a drug commonly prescribed for altitude sickness, on cortical oscillations in patients with obstructive sleep apnea syndrome (OSAS). 2) To examine alterations in the sleep EEG after short-term discontinuation of continuous positive airway pressure (CPAP) therapy. Design Data from two double-blind, placebo-controlled randomized cross-over design studies were analyzed. Setting Polysomnographic recordings in sleep laboratory at 490 m and at moderate altitudes in the Swiss Alps: 1630 or 1860 m and 2590 m. Patients Study 1: 39 OSAS patients. Study 2: 41 OSAS patients. Interventions Study 1: OSAS patients withdrawn from treatment with CPAP. Study 2: OSAS patients treated with autoCPAP. Treatment with acetazolamide (500–750 mg) or placebo at moderate altitudes. Measurements and Results An evening dose of 500 mg acetazolamide reduced slow-wave activity (SWA; approximately 10%) and increased spindle activity (approximately 10%) during non-REM sleep. In addition, alpha activity during wake after lights out was increased. An evening dose of 250 mg did not affect these cortical oscillations. Discontinuation of CPAP therapy revealed a reduction in SWA (5–10%) and increase in beta activity (approximately 25%). Conclusions The higher evening dose of 500 mg acetazolamide showed the “spectral fingerprint” of Benzodiazepines, while 250 mg acetazolamide had no impact on cortical oscillations. However, both doses had beneficial effects on oxygen saturation and sleep quality. PMID:24710341

  16. Obstructive sleep apnea in Type 2 diabetes and impact of continuous positive airway pressure therapy on glycemic control

    PubMed Central

    Malik, Javid Ahmad; Masoodi, Shariq Rashid; Shoib, Sheikh

    2017-01-01

    Background: Obstructive sleep apnea (OSA) and type 2 diabetes mellitus (T2DM) are two interacting epidemics both with high prevalence and morbidity. Both epidemiologic and clinical studies suggest that the majority of patients with T2DM also have OSA and untreated OSA in these patients results in poor glycemic control leading to acceleration of diabetes-related complications. Objectives: To assess the prevalence and severity of OSA in T2DM patients and to assess the impact of OSA treatment on presenting symptoms and hemoglobin A1c (HbA1c). Methods: We performed polysomnography (PSG) studies and measured HbA1c in 62 consecutive patients with T2DM that were referred from various subspecialty clinics from July 2011 to August 2013. Results: In our 62 diabetic patients, 59 (95.2%) had abnormal PSG. Based on Apnea–Hypopnea Index (AHI) score, 3 (5.1%) patients had mild, 28 (47.5%) had moderate, and 28 (47.5%) had severe OSA. The mean AHI of diabetic patients was significantly more than nondiabetic patients, i.e., 25.7 versus 19.7 (P = 0.001). Variables that significantly correlated with the presence of OSA include age, gender, body mass index (BMI), hypertension, diabetes, and cardiovascular disease (P < 0.05); however, on logistic regression only BMI, hypertension, and nocturia correlated with OSA. Overall, 59% of diabetic patients showed improvement in their glycemic control as measured by HbA1c with continuous positive airway pressure (CPAP) treatment. Significant, moderate, and mild categories of treatment response were respectively observed in 7%, 20%, and 32% of patients. Conclusion: Treatment of OSA with CPAP reduces HbA1c in a significant number of diabetics. PMID:28217508

  17. High Adherence to CPAP Treatment Does Not Prevent the Continuation of Weight Gain among Severely Obese OSAS Patients

    PubMed Central

    Myllylä, Minna; Kurki, Samu; Anttalainen, Ulla; Saaresranta, Tarja; Laitinen, Tarja

    2016-01-01

    Study Objectives: Obstructive sleep apnea syndrome (OSAS) patients benefit from continuous positive airway pressure (CPAP) treatment in a dose-response manner. We determined adherence and weight control, as well as their predictors, among long-term CPAP users. Methods: Cohort of 1,023 OSAS patients had used CPAP on average of 6.6 ± 1.2 years. BMI was determined at baseline and at follow-up visits. There were 7.4 ± 1.7 BMI and 6.5 ± 1.8 CPAP usage measurements per patient on average. Using the Bayesian hierarchical model, we determined the patients' individual trends of BMI and adherence development. Patients with significantly increasing or decreasing trends were identified at the posterior probability level of > 90%. Results: The mean age in the cohort was 55.6 ± 9.8 years, BMI 33.5 ± 6.4 kg/m2, apnea-hypopnea index 33.7 ± 23.1, and CPAP usage 6.0 ± 1.8 h/day. The majority of patients had no significant change in BMI (mean annual weight gain 0.04 ± 0.29 kg/m2) or CPAP adherence (mean annual increase 11.4 ± 7.0 min/day). However, at the individual level, 10% of the patients showed significant annual weight gain (0.63 ± 0.35 kg/m2) during the 5-year follow-up period. At baseline these patients were already more severely obese (mean BMI 40.0 ± 5.9 kg/m2) despite being younger (mean 50.9 ± 9.5 years) than the rest of the cohort. Conclusions: In the majority of CPAP-treated OSAS patients, weight did not significantly change but gained slightly slower than in age-matched population in general. However, in 10% of patients, high adherence to CPAP treatment did not prevent the continuation of weight gain. These patients present a high-risk group for OSAS-related multimorbidity later in life. Citation: Myllylä M, Kurki S, Anttalainen U, Saaresranta T, Laitinen T. High adherence to CPAP treatment does not prevent the continuation of weight gain among severely obese OSAS patients. J Clin Sleep Med 2016;12(4):519–528. PMID:26888588

  18. Non-CPAP therapies in obstructive sleep apnoea.

    PubMed

    Randerath, W J; Verbraecken, J; Andreas, S; Bettega, G; Boudewyns, A; Hamans, E; Jalbert, F; Paoli, J R; Sanner, B; Smith, I; Stuck, B A; Lacassagne, L; Marklund, M; Maurer, J T; Pepin, J L; Valipour, A; Verse, T; Fietze, I

    2011-05-01

    In view of the high prevalence and the relevant impairment of patients with obstructive sleep apnoea syndrome (OSAS) lots of methods are offered which promise definitive cures for or relevant improvement of OSAS. This report summarises the efficacy of alternative treatment options in OSAS. An interdisciplinary European Respiratory Society task force evaluated the scientific literature according to the standards of evidence-based medicine. Evidence supports the use of mandibular advancement devices in mild to moderate OSAS. Maxillomandibular osteotomy seems to be as efficient as continuous positive airway pressure (CPAP) in patients who refuse conservative treatment. Distraction osteogenesis is usefully applied in congenital micrognathia or midface hypoplasia. There is a trend towards improvment after weight reduction. Positional therapy is clearly inferior to CPAP and long-term compliance is poor. Drugs, nasal dilators and apnoea triggered muscle stimulation cannot be recommended as effective treatments of OSAS at the moment. Nasal surgery, radiofrequency tonsil reduction, tongue base surgery, uvulopalatal flap, laser midline glossectomy, tongue suspension and genioglossus advancement cannot be recommended as single interventions. Uvulopalatopharyngoplasty, pillar implants and hyoid suspension should only be considered in selected patients and potential benefits should be weighed against the risk of long-term side-effects. Multilevel surgery is only a salvage procedure for OSA patients.

  19. In vitro validation and clinical testing of an indirect calorimetry system for ventilated preterm infants that is unaffected by endotracheal tube leaks and can be used during nasal continuous positive airway pressure.

    PubMed

    Bauer, K; Ketteler, J; Laurenz, M; Versmold, H

    2001-03-01

    Energy expenditure measurements in ventilated preterm infants are difficult because indirect calorimetry underestimates energy expenditure during gas leaks around uncuffed endotracheal tubes routinely used in preterm infants or during nasal continuous positive airway pressure (CPAP). We, therefore, developed a breath collector that simultaneously sampled expired air expelled at the ventilator outlet and escaping via the tube leak from the infant's mouth and nose. Our breath collector was combined with a proprietary calorimeter (Deltatrac II). In vitro validation was done by methanol burning (VO(2), 13.8 mL/min; VCO(2), 9.2 mL/min) during intermittent positive pressure ventilation (IPPV) with two commonly used ventilators (Sechrist IV-100B and Infant Star). Measurement error was determined at different ventilator flows, peak inspiratory pressures of 12-24 cm H(2)O, and during a complete tube leak. The mean measurement error with both ventilators was low (VO(2) +/- 3 %, VCO(2) +/- 2 %) even during a complete tube leak and did not increase with peak inspiratory pressure. The system response time was 2 min. In vivo measurements at the bedside were performed in 25 preterm infants (body weight, 537-1402 g). Energy expenditure during IPPV was 40 +/- 9 kcal/kg per day and 46 +/- 15 kcal/kg per day during nasal CPAP. The tube leak in the preterm infants studied during IPPV was 0 to 47 %, and during nasal CPAP 84 to 97 %. In conclusion, indirect calorimetry performed with our breath collector was accurate during IPPV and nasal CPAP and was unaffected by tube leaks.

  20. Impact of CPAP on physical exercise tolerance and sympathetic-vagal balance in patients with chronic heart failure

    PubMed Central

    Reis, Hugo V.; Borghi-Silva, Audrey; Catai, Aparecida M.; Reis, Michel S.

    2014-01-01

    Background: Chronic heart failure (CHF) leads to exercise intolerance. However, non-invasive ventilation is able to improve functional capacity of patients with CHF. Objectives: The aim of this study was to evaluate the effectiveness of continuous positive airway pressure (CPAP) on physical exercise tolerance and heart rate variability (HRV) in patients with CHF. Method : Seven men with CHF (62±8 years) and left ventricle ejection fraction of 41±8% were submitted to an incremental symptom-limited exercise test (IT) on the cicloergometer. On separate days, patients were randomized to perform four constant work rate exercise tests to maximal tolerance with and without CPAP (5 cmH2O) in the following conditions: i) at 50% of peak work rate of IT; and ii) at 75% of peak work rate of IT. At rest and during these conditions, instantaneous heart rate (HR) was recorded using a cardiofrequencimeter and HRV was analyzed in time domain (SDNN and RMSSD indexes). For statistical procedures, Wilcoxon test or Kruskall-Wallis test with Dunn's post-hoc were used accordingly. In addition, categorical variables were analysed through Fischer's test (p<0.05). Results: There were significant improvements in exercise tolerance at 75% of peak work rate of IT with CPAP (405±52 vs. 438±58 s). RMSSD indexes were lower during exercise tests compared to CPAP at rest and with 50% of peak work rate of IT. Conclusion: These data suggest that CPAP appears to be a useful strategy to improve functional capacity in patients with CHF. However, the positive impact of CPAP did not generate significant changes in the HRV during physical exercises. PMID:25003274

  1. Effect of CPAP on intrinsic PEEP, inspiratory effort, and lung volume in severe stable COPD

    PubMed Central

    O'Donoghue, F; Catcheside, P; Jordan, A; Bersten, A; McEvoy, R

    2002-01-01

    Background: Intrinsic positive end expiratory pressure (PEEPi) constitutes an inspiratory threshold load on the respiratory muscles, increasing work of breathing. The role of continuous positive airway pressure (CPAP) in alleviating PEEPi in patients with severe stable chronic obstructive pulmonary disease is uncertain. This study examined the effect of CPAP on the inspiratory threshold load, muscle effort, and lung volume in this patient group. Methods: Nine patients were studied at baseline and with CPAP increasing in increments of 1 cm H2O to a maximum of 10 cm H2O. Breathing pattern and minute ventilation (I), dynamic PEEPi, expiratory muscle activity, diaphragmatic (PTPdi/min) and oesophageal (PTPoes/min) pressure-time product per minute, integrated diaphragmatic (EMGdi) and intercostal EMG (EMGic) and end expiratory lung volume (EELV) were measured. Results: Expiratory muscle activity was present at baseline in one subject. In the remaining eight, PEEPi was reduced from a mean (SE) of 2.9 (0.6) cm H2O to 0.9 (0.1) cm H2O (p<0.05). In two subjects expiratory muscle activity contributed to PEEPi at higher pressures. There were no changes in respiratory pattern but I increased from 9.2 (0.6) l/min to 10.7 (1.1) l/min (p<0.05). EMGdi remained stable while EMGic increased significantly. PTPoes/min decreased, although this did not reach statistical significance. PTPdi/min decreased significantly from 242.1 (32.1) cm H2O.s/min to 112.9 (21.7) cm H2O.s/min). EELV increased by 1.1 (0.3) l (p<0.01). Conclusion: High levels of CPAP reduce PEEPi and indices of muscle effort in patients with severe stable COPD, but only at the expense of substantial increases in lung volume. PMID:12037230

  2. Is treatment of obstructive sleep apnea syndrome with auto-CPAP useful?

    PubMed

    Sériès, F

    2000-06-15

    Automatic CPAP therapy has been developed to constantly adapt the positive pressure level to the required needs. The automatic devices have been used in two different ways, one being to determine the pressure level to be prescribed at home for fixed CPAP therapy, and the other one to replace fixed CPAP as an home treatment. This last application should alleviate the need for a titration study. The benefits reported up to now in the literature vary from one machine to another, but usually these machine are effective in abolishing obstructive breathing disturbances and the consecutive sleep fragmentation. The mean positive pressure level applied during automatic CPAP treatment is usually less than the effective pressure level measured during a conventional titration sleep study. Some results suggest that automatic CPAP therapy may improve compliance to CPAP therapy. There is a need to better define if automatic CPAP therapy may benefit to specific groups of sleep apnea patients.

  3. Pressure-volume behaviour of the rat upper airway: effects of tongue muscle activation

    PubMed Central

    Bailey, E Fiona; Fregosi, Ralph F

    2003-01-01

    Our hypothesis was that the simultaneous activation of tongue protrudor and retractor muscles (co-activation) would constrict and stiffen the pharyngeal airway more than the independent activation of tongue protrudor muscles. Upper airway stiffness was determined by injecting known volumes of air into the sealed pharyngeal airway of the anaesthetized rat while measuring nasal pressure under control (no-stimulus) and stimulus conditions (volume paired with hypoglossal (XII) nerve stimulation). Stimulation of the whole XII nerves (co-activation) or the medial XII branches (protrudor activation) effected similar increases in total pharyngeal airway stiffness. Importantly, co-activation produced volume compression (airway narrowing) at large airway volumes (P < 0.05), but had no effect on airway dimension at low airway volumes. In comparison, protrudor activation resulted in significant volume expansion (airway dilatation) at low airway volumes and airway narrowing at high airway volumes (P < 0.05). In conclusion, both co-activation and independent protrudor muscle activation increase airway stiffness. However, their effects on airway size are complex and depend on the condition of the airway at the time of activation. PMID:12640023

  4. Advances in Positive Airway Pressure Treatment Modalities for Hypoventilation Syndromes

    PubMed Central

    Combs, Dan; Shetty, Safal; Parthasarathy, Sairam

    2014-01-01

    SYNOPSIS Rationale Positive airway pressure therapy for hypoventilation syndromes can significantly improve health-related quality of life (HR-QOL), healthcare costs, and even mortality. The sleep-disordered breathing in such individuals are quite complex and require sophisticated devices with algorithms that are designed to accurately detect and effectively treat respiratory events that includes hypoventilation, upper airway obstruction, lower airway obstruction, central apneas and central hypopneas and reduce the work of breathing while maintaining breathing comfort. Objectives The therapeutic physiological rationale for the various advanced PAP modalities and the details about the principles of operation and technology implementation are provided here. Conclusions The physiological rationale for advanced PAP modalities is sound considering the complexity of sleep-disordered breathing in patients with hypoventilation syndromes. Although such devices are increasingly used in clinical practice, the supporting clinical evidence – specifically comparative-effectiveness studies in real-life conditions -- needs to be performed. Moreover, there is much opportunity for further refining these devices that include the ability of the device to reliably monitor gas-exchange, sleep-wakefulness state, and for reducing variability in device efficacy due to provider-selected device-settings. PMID:25346650

  5. Effects of Continuous Positive Airway Pressure on Cognitive Deficits in Middle-aged Patients with Obstructive Sleep Apnea Syndrome: A Meta-analysis of Randomized Controlled Trials

    PubMed Central

    Pan, Yue-Ying; Deng, Yan; Xu, Xiu; Liu, Ya-Ping; Liu, Hui-Guo

    2015-01-01

    Background: Current views on continuous positive airway pressure (CPAP) treatment to improve the cognitive deficits of patients with obstructive sleep apnea syndrome (OSAS) are controversial, so we performed a meta-analysis. Methods: A comprehensive literature search was undertaken in PubMed, CINAHL, Medline, PsycInfo, EMBASE, Cochrane Library, CNKI, WanFang, VIP, and CBMdisc for studies published from June 1971 to July 2014. The outcome measures included neuropsychological tests of the 7 cognitive domains detailed below. Results: After screening the titles and abstracts and thoroughly reading the full text, we obtained 13 studies with little risk of bias that incorporated 1744 middle-aged obese participants with mild to severe OSAS. The studies were published from 1994 to 2012. Treatment durations varied from 1 to 24 weeks. The effect sizes of attention, vigilance, processing speed, working memory, memory, verbal fluency, and visuoconstructive skills domains were −0.10 (P = 0.24), −0.12 (P = 0.04), −0.08 (P = 0.16), 0.00 (P = 0.95), −0.04 (P = 0.30), −0.06 (P = 0.34), and −0.01 (P = 0.92), respectively. Conclusions: Cognition partially improved in patients with OSAS after CPAP treatment. The only domain with significant improvement was vigilance. Rigorous randomized controlled trials need to be performed to obtain clear results. PMID:26315086

  6. Effect of CPAP on Cardiac Function in Minimally Symptomatic Patients with OSA: Results from a Subset of the MOSAIC Randomized Trial

    PubMed Central

    Craig, Sonya; Kylintireas, Ilias; Kohler, Malcolm; Nicoll, Debby; Bratton, Daniel J.; Nunn, Andrew J.; Leeson, Paul; Neubauer, Stefan; Stradling, John R.

    2015-01-01

    Study Objectives: Minimally symptomatic obstructive sleep apnea (OSA) is highly prevalent, and the effects of continuous positive airway pressure (CPAP) on myocardial function in these patients are unknown. The MOSAIC randomized, controlled trial of CPAP for minimally symptomatic OSA assessed the effect of CPAP on myocardial function in a subset of patients. Methods: Two centers taking part in the MOSAIC trial randomized 238 patients in parallel to 6 months of CPAP (120) or standard care (118). Of these, 168 patients had echocardiograms, and 68 patients had a cardiac magnetic resonance scan (CMR). A larger group (314) from 4 centers had brain natriuretic peptide (BNP) measured. Results: Mean (SD) baseline oxygen desaturation index (ODI) and Epworth sleepiness score (ESS) were 13.5 (13.2), and 8.4 (4.0), respectively. CPAP significantly reduced ESS and ODI. Baseline LV ejection fraction (LVEF) was well preserved (60.4%). CPAP had no significant effect on echo-derived left atrial (LA) area (−1.0 cm2, 95% CI −2.6 to +0.6, p = 0.23) or early to late left ventricular filling velocity (E/A) ratio (−0.01, 95% CI −0.07 to +0.05, p = 0.79). There was a small change in echo-derived LV end diastolic volume (EDV) with CPAP (−5.9 mL, 95% CI −10.6 to −1.2, p = 0.015). No significant changes were detected by CMR on LV mass index (+1.1 g/m2, 95% CI −5.9 to +8.0, p = 0.76) or LVEF (+0.8%, 95% CI −1.2 to +2.8, p = 0.41). CPAP did not affect BNP levels (p = 0.16). Conclusions: Six months of CPAP therapy does not change cardiac functional or structural parameters measured by echocardiogram or CMR in patients with minimally symptomatic mild-to-moderate OSA. Clinical Trial Registration: ISRCTN 34164388 (http://isrctn.org). Citation: Craig S, Kylintireas I, Kohler M, Nicoll D, Bratton DJ, Nunn AJ, Leeson P, Neubauer S, Stradling JR. Effect of CPAP on cardiac function in minimally symptomatic patients with OSA: results from a subset of the MOSAIC randomized trial. J Clin

  7. Can breathing-like pressure oscillations reverse or prevent narrowing of small intact airways?

    PubMed

    Harvey, Brian C; Parameswaran, Harikrishnan; Lutchen, Kenneth R

    2015-07-01

    Periodic length fluctuations of airway smooth muscle during breathing are thought to modulate airway responsiveness in vivo. Recent animal and human intact airway studies have shown that pressure fluctuations simulating breathing can only marginally reverse airway narrowing and are ineffective at protecting against future narrowing. However, these previous studies were performed on relatively large (>5 mm diameter) airways, which are inherently stiffer than smaller airways for which a preponderance of airway constriction in asthma likely occurs. The goal of this study was to determine the effectiveness of breathing-like transmural pressure oscillations to reverse induced narrowing and/or protect against future narrowing of smaller, more compliant intact airways. We constricted smaller (luminal diameter = 2.92 ± 0.29 mm) intact airway segments twice with ACh (10(-6) M), once while applying tidal-like pressure oscillations (5-15 cmH2O) before, during, and after inducing constriction (Pre + Post) and again while only imposing the tidal-like pressure oscillation after induced constriction (Post Only). Smaller airways were 128% more compliant than previously studied larger airways. This increased compliance translated into 196% more strain and 76% greater recovery (41 vs. 23%) because of tidal-like pressure oscillations. Larger pressure oscillations (5-25 cmH2O) caused more recovery (77.5 ± 16.5%). However, pressure oscillations applied before and during constriction resulted in the same steady-state diameter as when pressure oscillations were only applied after constriction. These data show that reduced straining of the airways before a challenge likely does not contribute to the emergence of airway hyperreactivity observed in asthma but may serve to sustain a given level of constriction.

  8. Can breathing-like pressure oscillations reverse or prevent narrowing of small intact airways?

    PubMed Central

    Harvey, Brian C.; Parameswaran, Harikrishnan

    2015-01-01

    Periodic length fluctuations of airway smooth muscle during breathing are thought to modulate airway responsiveness in vivo. Recent animal and human intact airway studies have shown that pressure fluctuations simulating breathing can only marginally reverse airway narrowing and are ineffective at protecting against future narrowing. However, these previous studies were performed on relatively large (>5 mm diameter) airways, which are inherently stiffer than smaller airways for which a preponderance of airway constriction in asthma likely occurs. The goal of this study was to determine the effectiveness of breathing-like transmural pressure oscillations to reverse induced narrowing and/or protect against future narrowing of smaller, more compliant intact airways. We constricted smaller (luminal diameter = 2.92 ± 0.29 mm) intact airway segments twice with ACh (10−6 M), once while applying tidal-like pressure oscillations (5–15 cmH2O) before, during, and after inducing constriction (Pre + Post) and again while only imposing the tidal-like pressure oscillation after induced constriction (Post Only). Smaller airways were 128% more compliant than previously studied larger airways. This increased compliance translated into 196% more strain and 76% greater recovery (41 vs. 23%) because of tidal-like pressure oscillations. Larger pressure oscillations (5–25 cmH2O) caused more recovery (77.5 ± 16.5%). However, pressure oscillations applied before and during constriction resulted in the same steady-state diameter as when pressure oscillations were only applied after constriction. These data show that reduced straining of the airways before a challenge likely does not contribute to the emergence of airway hyperreactivity observed in asthma but may serve to sustain a given level of constriction. PMID:25953836

  9. Evaluation of an oral appliance in patients with mild to moderate obstructive sleep apnea syndrome intolerant to continuous positive airway pressure use: Preliminary results.

    PubMed

    Cantore, S; Ballini, A; Farronato, D; Malcangi, G; Dipalma, G; Assandri, F; Garagiola, U; Inchingolo, F; De Vito, D; Cirulli, N

    2016-06-01

    Obstructive sleep apnea syndrome (OSAS) is a phenomenon of repeated, episodic reduction, or cessation of airflow (hypopnea/apnea) as a result of upper airways obstruction. First-line treatment in younger children is adenotonsillectomy, although other available treatment options in middle-aged adults include continuous positive airways pressure (CPAP) and airway adjuncts. Oral appliances (OA) are a viable treatment alternative in patients with OSAS.The objective of this study was to assess, in a 1-year follow-up study, an OA in OSAS patients. The participants were subjected to polysomnographic examination with a validated device (MicroMESAM). Eight participants were fitted with a Thornton Adjustable Positioner (TAP). The participants were asked to wear the test appliance for 7 nights, and in case of compliance, for 6 months. The selected patients record their usage of the appliance and any adverse effects in a treatment journal. The research focused on the following outcomes: sleep apnea (i.e. reduction in the apnea/hypopnea index) and the effect of oral appliances on daytime function.In conclusion, the results suggest that OA have a definite role in the treatment of snoring and sleep apnea.

  10. Validation of airway resistance models for predicting pressure loss through anatomically realistic conducting airway replicas of adults and children.

    PubMed

    Borojeni, Azadeh A T; Noga, Michelle L; Martin, Andrew R; Finlay, Warren H

    2015-07-16

    This work describes in vitro measurement of the total pressure loss at varying flow rate through anatomically realistic conducting airway replicas of 10 children, 4 to 8 years old, and 5 adults. Experimental results were compared with analytical predictions made using published airway resistance models. For the adult replicas, the model proposed by van Ertbruggen et al. (2005. J. Appl. Physiol. 98, 970-980) most accurately predicted central conducting airway resistance for inspiratory flow rates ranging from 15 to 90 L/min. Models proposed by Pedley et al. (1970. J. Respir. Physiol. 9, 371-386) and by Katz et al. (2011. J. Biomech. 44, 1137-1143) also provided reasonable estimates, but with a tendency to over predict measured pressure loss for both models. For child replicas, the Pedley and Katz models both provided good estimation of measured pressure loss at flow rates representative of resting tidal breathing, but under predicted measured values at high inspiratory flow rate (60 L/min). The van Ertbruggen model, developed based on flow simulations performed in an adult airway model, tended to under predict measured pressure loss through the child replicas across the range of flow rates studied (2 to 60 L/min). These results are intended to provide guidance for selection of analytical pressure loss models for use in predicting airway resistance and ventilation distribution in adults and children.

  11. Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnea syndrome: a randomized, placebo-controlled trial on self-reported symptoms of common sleep disorders and sleep-related problems.

    PubMed

    Nikolopoulou, Maria; Byraki, Anna; Ahlberg, Jari; Heymans, Martijn W; Hamburger, H L; De Lange, Jan; Lobbezoo, Frank; Aarab, Ghizlane

    2017-03-10

    Obstructive sleep apnea syndrome (OSAS) is associated with several sleep disorders and sleep-related problems. Therefore, the aim of this study was to compare the effects of a mandibular advancement device (MAD) with those of nasal continuous positive airway pressure (nCPAP) on self-reported symptoms of common sleep disorders and sleep-related problems in mild and moderate OSAS patients. In this randomized placebo-controlled trial sixty-four OSAS patients (52.0± 9.6 years) were randomly assigned to an MAD, nCPAP or an intra-oral placebo appliance in a parallel design. All participants filled out the validated Dutch Sleep Disorders Questionnaire (SDQ) twice: one before treatment and one after six months of treatment. With 88 questions, thirteen scales were constructed, representing common sleep disorders and sleep-related problems. Linear mixed model analyses were performed to study differences between the groups for the different SDQ scales over time. The MAD group showed significant improvements over time in symptoms corresponding with "insomnia", "excessive daytime sleepiness", "psychiatric sleep disorder", "periodic limb movements", "sleep apnea", "sleep paralysis", "daytime dysfunction", "hypnagogic hallucinations/dreaming", "restless sleep", "negative conditioning", and "automatic behaviour" (range of P values: 0.000-0.014). These improvements in symptoms were, however, not significantly different from the improvements in symptoms observed in the nCPAP and placebo groups (range of P values: 0.090-0.897). It can be concluded that there is no significant difference between MAD and nCPAP in their positive effects on self-reported symptoms of common sleep disorders and sleep-related problems in mild and moderate OSAS patients. These beneficial effects may be a result of placebo effects. This article is protected by copyright. All rights reserved.

  12. Vascular tracers alter hemodynamics and airway pressure in anesthetized sheep

    SciTech Connect

    Albertine, K.H.; Staub, N.C.

    1986-11-01

    The technique of vascular labeling was developed to mark sites of increased microvascular permeability. We used the vascular labeling technique in anesthetized sheep and found that hemodynamics and airway pressure were adversely affected by intraarterial infusions of two vascular tracers. Monastral blue (nine sheep) immediately caused systemic arterial hypotension, pulmonary arterial hypertension, and bronchoconstriction. All three physiological responses were partially blocked by a cyclooxygenase inhibitor (indomethacin) but not by an H1-antihistamine (chlorpheniramine). Colloidal gold (nine sheep) caused immediate, but less dramatic, pulmonary arterial hypertension which was not attenuated by the blocking agents. We conclude that these two vascular tracers caused detrimental physiological side effects in sheep at the usual doses used to label injured microvessels in other species.

  13. Assessment of volume and leak measurements during CPAP using a neonatal lung model.

    PubMed

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.

  14. Pediatric Positive Airway Pressure Adherence in Obstructive Sleep Apnea Enhanced by Family Member Positive Airway Pressure Usage

    PubMed Central

    Puri, Pooja; Ross, Kristie R.; Mehra, Reena; Spilsbury, James C.; Li, Hong; Levers-Landis, Carolyn E.; Rosen, Carol L.

    2016-01-01

    Study Objectives: Adherence to positive airway pressure (PAP) therapy for obstructive sleep apnea (OSA) remains a challenge in children. We hypothesized that the presence of another family member on PAP therapy (parent, sibling, other family member) would be associated with better adherence in the child. Methods: We conducted a retrospective chart review to identify children < 18 years of age who had a new diagnosis of OSA between Jan 2011 and May 2013. Outcomes were objective PAP adherence at 1 week, 1 month, and 3 months. Potential predictors included family member on PAP therapy, patient demographics, and clinical characteristics. Group differences between children with and without a family member on PAP therapy were determined using χ2 test and Wilcoxon two-sample test. PAP adherence measures at each time point and patterns of change across time between the two groups were examined using mixed-effects models. Results: The final analytic sample included 56 children: age 13.2 ± 3.7 years, 60% male, 67% African American, 65% obese, and 32% with developmental disabilities. The mean obstructive apnea-hypopnea index was 25.2 ± 28.7, and 19 (33%) had a family member on PAP therapy. Overall PAP adherence was 2.8 ± 2.4 h/night at 3 months. At month 3, the group with a family member on PAP therapy had significantly greater average nightly PAP use on all nights (3.6 ± 0.6 vs. 2.3 ± 0.39) and on nights used (4.8 ± 0.6 vs. 3.8 ± 0.40); (p value = 0.04). Conclusions: Overall PAP adherence was low, but having a family member on PAP therapy as a “role model” was associated with better adherence. Commentary: A commentary on this article appears in this issue on page 941. Citation: Puri P, Ross KR, Mehra R, Spilsbury JC, Li H, Levers-Landis CE, Rosen CL. Pediatric positive airway pressure adherence in obstructive sleep apnea enhanced by family member positive airway pressure usage. J Clin Sleep Med 2016;12(7):959–963. PMID:27092699

  15. The role of noninvasive ventilation: CPAP and BiPAP in the treatment of congestive heart failure.

    PubMed

    Stoltzfus, Sam

    2006-01-01

    Congestive heart failure (CHF) is a common cause of respiratory failure for which patients seek emergency care. Mechanical ventilation is commonly used in the treatment for severe CHF. Studies have shown that noninvasive ventilation (NIV) methods, such as continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP), are effective in treating CHF and have fewer complications than endotracheal intubation. The use of NIV in the treatment of CHF has been shown to increase oxygenation, improve hemodynamic stability, and decrease the need for intubation. When NIV is chosen for a patient in CHF, the critical care nurse needs to be vigilant in assessing and monitoring these patients, especially those in severe CHF. This article evaluates the differences between the 2 types of NIV, the controversies that may exist, practice issues for the critical care nurse, and any financial considerations.

  16. Deviation of tracheal pressure from airway opening pressure during high-frequency oscillatory ventilation in a porcine lung model.

    PubMed

    Johannes, Amélie; Zollhoefer, Bernd; Eujen, Ulrike; Kredel, Markus; Rauch, Stefan; Roewer, Norbert; Muellenbach, Ralf M

    2013-04-01

    Oxygenation during high-frequency oscillatory ventilation is secured by a high level of mean airway pressure. Our objective was to identify a pressure difference between the airway opening of the respiratory circuit and the trachea during application of different oscillatory frequencies. Six female Pietrain pigs (57.1 ± 3.6 kg) were first ventilated in a conventional mechanical ventilation mode. Subsequently, the animals were switched to high-frequency oscillatory ventilation by setting mean airway opening pressure 5 cmH(2)O above the one measured during controlled mechanical ventilation. Measurements at the airway opening and at tracheal levels were performed in healthy lungs and after induction of acute lung injury by surfactant depletion. During high-frequency oscillatory ventilation, the airway opening pressure was set at a constant level. The pressure amplitude was fixed at 90 cmH(2)O. Starting from an oscillatory frequency of 3 Hz, the frequency was increased in steps of 3 Hz to 15 Hz and then decreased accordingly. At each frequency, measurements were performed in the trachea through a side-lumen of the endotracheal tube and the airway opening pressure was recorded. The pressure difference was calculated. At every oscillatory frequency, a pressure loss towards the trachea could be shown. This pressure difference increased with higher oscillatory frequencies (3 Hz 2.2 ± 2.1 cmH(2)O vs. 15 Hz 7.5 ± 1.8 cmH(2)O). The results for healthy and injured lungs were similar. Tracheal pressures decreased with higher oscillatory frequencies. This may lead to pulmonary derecruitment. This has to be taken into consideration when increasing oscillatory frequencies and differentiated pressure settings are mandatory.

  17. Protective Effect of Long-Term CPAP Therapy on Cognitive Performance in Elderly Patients with Severe OSA: The PROOF Study

    PubMed Central

    Crawford-Achour, Emilie; Dauphinot, Virginie; Saint Martin, Magali; Tardy, Magali; Gonthier, Régis; Barthelemy, Jean Claude; Roche, Frédéric

    2015-01-01

    Objective: Obstructive sleep apnea syndrome (OSA) leads to a deterioration in cognitive functions, with regard to memory and executive functions. However, few studies have investigated the impact of treatment on these cognitive functions in elderly subjects. Methods: The study was conducted in a large cohort of subjects aged 65 years or older (the PROOF cohort). Subjects were not diagnosed or treated for OSA. Subjects underwent a polygraphic recording. Cognitive performance was assessed in all OSA subjects at baseline and 10 years later, whether or not they were receiving continuous positive airway pressure (CPAP) therapy. Results: A group of 126 patients were analyzed. Only 26% of them were treated, with therapy initiated at the discretion of the primary care physician. Among treated subjects, self-reported compliance with therapy was good (> 6 h/night on average), and 66% of them reported an improvement in their quality of life. Patients receiving CPAP treatment had a higher apneahypopnea index (p = 0.006), a higher oxygen desaturation index (p < 0.001), and experienced more pronounced daytime repercussions (p = 0.004). These patients showed a statistically significant improvement in mental agility (similarities test; p < 0.0001) and memory performance (Grober and Buschke delayed free recall; p = 0.02). Conclusion: CPAP treatment is associated with the maintenance of memory performance over time. Citation: Crawford-Achour E, Dauphinot V, Saint Martin M, Tardy M, Gonthier R, Barthelemy JC, Roche F. Protective effect of long-term CPAP therapy on cognitive performance in elderly patients with severe OSA: the PROOF study. J Clin Sleep Med 2015;11(5):519–524. PMID:25700873

  18. CPAP Adherence in Patients with Newly Diagnosed Obstructive Sleep Apnea prior to Elective Surgery

    PubMed Central

    Guralnick, Amy S.; Pant, Melissa; Minhaj, Mohammed; Sweitzer, Bobbie Jean; Mokhlesi, Babak

    2012-01-01

    Background: Obstructive sleep apnea (OSA) is prevalent in the surgical population, and it has been suggested that preoperative patients should be screened and treated for OSA. However, it remains unclear whether patients diagnosed with OSA in the preoperative period adhere to prescribed CPAP therapy. Objective: Our aim was to objectively quantify CPAP adherence, investigate predictors of poor CPAP adherence, and to establish an optimal CPAP setting in a cohort of presurgical patients diagnosed with OSA as part of the preoperative work-up. Methods: In a retrospective observational study, we collected data on all adult presurgical patients seen by the Anesthesia Perioperative Medicine Clinic (APMC) who screened positive for OSA on the STOP-Bang questionnaire and underwent an in-laboratory diagnostic polysomnogram (PSG) before surgery. CPAP was offered to patients with moderate or severe OSA. Objective CPAP adherence was recorded during the perioperative period. Factors associated with reduced CPAP adherence were delineated. Patient characteristics were compared between those with STOP-Bang scores of 3-4 and those with higher scores (STOP-Bang score ≥ 5). Results: During a 2-year period, 431 patients were referred and 211 patients completed a PSG. CPAP therapy was required in 65% of patients, and the optimal level was 9 ± 2 cm H2O. Objective CPAP adherence was available in 75% of patients who received CPAP therapy; median adherence was 2.5 h per night, without any significant difference between the STOP-Bang subgroups. African American race, male gender, and depressive symptomatology were independent predictors of reduced CPAP adherence. Severe OSA was significantly more prevalent in patients with a STOP-Bang score ≥ 5 than those whose score was 3-4 (55.1% versus 34.4%, p = 0.005). However, optimum CPAP pressure levels and adherence to therapy did not differ between the 2 STOP-Bang groups. Conclusions: Adherence to prescribed CPAP therapy during the perioperative

  19. Effects of a Short Course of Eszopiclone on Continuous Positive Airway Pressure Adherence

    DTIC Science & Technology

    2009-11-17

    from a down- loadable “ smart card ” adherence-monitoring device (En- core Pro smart card , Phillips Respironics). These cards, which are integrated into...the time of enrollment (baseline) and again at 1, 3, and 6 months after initiating CPAP. In addition, we collected smart cards at 1, 3, and 6 months and...eszopiclone (n = 80) Initiated: 76 Did not initiate: 4 Discontinued: 2 Month 1 Discontinued CPAP: 8 No smart card data: 2 Month 3 Discontinued CPAP: 4 No

  20. Intermittent positive airway pressure to manage hypoxia during one-lung anaesthesia.

    PubMed

    Russell, W J

    2009-05-01

    The effect of intermittent positive airway pressure to the non-ventilated lung was assessed in 10 patients who desaturated during one-lung ventilation. Once their saturation fell below 95% they were given a slow inflation of 2 l/min of oxygen into the non-ventilated lung for two seconds. This was repeated every 10 seconds for five minutes or until the saturation rose to 98%, whichever was sooner. The initial mean SpO2 was 89.3% +/- 4.2%. All 10 patients had an increase in saturation. The mean saturation following intermittent positive airway pressure was 96.5% +/- 1.6% (P < 0.0001). Similarly, the mean oxygen tension rose from 67.2 +/- 12.8 mmHg to 98.9 +/- 19.8 mmHg. Intermittent positive airway pressure should be considered for patients who desaturate while undergoing one-lung ventilation.

  1. COMPLIANCE MEASUREMENTS OF THE UPPER AIRWAY IN PEDIATRIC DOWN SYNDROME SLEEP APNEA PATIENTS

    PubMed Central

    Subramaniam, Dhananjay Radhakrishnan; Mylavarapu, Goutham; McConnell, Keith; Fleck, Robert J.; Shott, Sally R.; Amin, Raouf S.; Gutmark, Ephraim J.

    2015-01-01

    Compliance of soft tissue and muscle supporting the upper airway are two of several factors contributing to pharyngeal airway collapse. We present a novel, minimally invasive method of estimating regional variations in pharyngeal elasticity. Magnetic resonance images for pediatric sleep apnea patients with Down syndrome (9.5 ± 4.3 years (mean age ± standard deviation)) were analyzed to segment airways corresponding to baseline (no mask pressure) and two positive pressures. A three dimensional map was created to evaluate axial and circumferential variation in radial displacements of the airway, dilated by the positive pressures. The displacements were then normalized with respect to the appropriate transmural pressure and radius of an equivalent circle to obtain a measure of airway compliance. The resulting elasticity maps indicated the least and most compliant regions of the pharynx. Airway stiffness of the most compliant region (403 ± 204 (mean ± standard deviation) Pa) decreased with severity of OSA. The non-linear response of the airway wall to CPAP was patient specific and varied between anatomical locations. We identified two distinct elasticity phenotypes. Patient phenotyping based on airway elasticity can potentially assist clinical practitioners in decision making on the treatments needed to improve airway patency. PMID:26215306

  2. A mobile, web-based system can improve positive airway pressure adherence.

    PubMed

    Hostler, Jordanna M; Sheikh, Karen L; Andrada, Teotimo F; Khramtsov, Andrei; Holley, Paul R; Holley, Aaron B

    2017-04-01

    SleepMapper is a mobile, web-based system that allows patients to self-monitor their positive airway pressure therapy, and provides feedback and education in real time. In addition to the usual, comprehensive support provided at our clinic, we gave the SleepMapper to 30 patients initiating positive airway pressure. They were compared with patients initiating positive airway pressure at our clinic without SleepMapper (controls) to determine whether SleepMapper affected adherence. A total of 61 patients had polysomnographic and adherence data analysed, 30 were given SleepMapper and 31 received our standard of care. The two groups were well matched at baseline to include no significant differences in age, apnea-hypopnea index, percentage receiving split-night polysomnographs and starting pressures. Patients in the control group received significantly more non-benzodiazepine sedative hypnotics the night of their polysomnography and during positive airway pressure initiation. At 11 weeks, patients in the SleepMapper group had a greater percentage of nights with any use (78.0 ± 22.0 versus 55.5 ± 24.0%; P < 0.001) and >4 h positive airway pressure use (78.0 ± 22.0 versus 55.5 ± 24.0%; P = 0.02). There was a trend toward more patients in the SleepMapper group achieving >4 h of use for at least 70% of nights [9/30 (30%) versus 3/31 (9.7%); P = 0.06]. In multivariate linear regression, the SleepMapper remained significantly associated with percentage of nights >4 h positive airway pressure use (β coefficient = 0.18; P = 0.02). Added to our usual, comprehensive programme to maximize positive airway pressure adherence in new users, the SleepMapper was independently associated with an 18% increase in nights >4 h of use.

  3. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators].

    PubMed

    Nishimura, M; Imanaka, H; Taenaka, N; Yoshiya, I; Takezawa, J

    1989-08-01

    The ventilator-induced work during continuous positive airway pressure (CPAP) mode in demand-valve ventilators was evaluated by using a piston pump as a simulator for active breathing. A piston pump delivered and withdrew a stroke volume of 500 ml at rates of 10, 20 and 40 cycle.min-1 with a sinusoidal waveform. A hot-wire flowmeter and a differential pressure transducer were interposed between the pump and ventilators and their signals were fed to a microcomputer to display a pressure-volume loop. The area of the loop was divided into the four parts. Inspiratory work associated with the opening of the demand valve was represented by the area of baseline airway pressure (BPa) during inspiration. The remaining area during inspiration reflected the work done by the ventilators. Expiratory work for overcoming the flow resistance of the expiratory apparatus was represented by the area above BPa during exhalation. The fourth was the area below the baseline during exhalation. The Puritan-Bennett 7200a, the Bear 5, the Siemens Servo 900C, the Hamilton Veolar, the Bird 6400ST, the Engström Erica, the Dräger EV-A, and the CPU-1 were examined at varying CPAP and pressure support levels. Because of demand valve oscillation throughout inspiration, the inspiratory workload of the Bear 5, the Siemens Servo 900C, the Hamilton Veolar, the Bird 6400ST, and the Dräger EV-A could not be calculated. Expiratory flow-resistive work was higher in the Siemens Servo 900C and the Bird 6400ST than the others. The present system can assess the entire performance of ventilators, and may serve to compare ventilators' performance.

  4. Impact of Untreated Obstructive Sleep Apnea on Left and Right Ventricular Myocardial Function and Effects of CPAP Therapy

    PubMed Central

    Wiesen, Martin; Momcilovic, Diana; Pabst, Stefan; Nickenig, Georg; Skowasch, Dirk

    2013-01-01

    Background Obstructive sleep apnea (OSA) has deteriorating effect on LV function, whereas its impact on RV function is controversial. We aimed to determine the effect of OSA and continuous positive airway pressure (CPAP) treatment on left and right ventricular (LV, RV) function using transthoracic echocardiography (TTE) and 2 dimensional speckle tracking (2D ST) analysis of RV deformation capability. Methods and Results 82 patients with OSA and need for CPAP therapy were prospectively enrolled and underwent TTE at study inclusion and after 6 months of follow up (FU). Multivariate regression analysis revealed an independent association between baseline apical right ventricular longitudinal strain (RV-Sl), BMI and the severity of OSA (apical RV-Sl: P = 0.0002, BMI: P = 0.02). After CPAP therapy, LV functional parameters (LVEF: P<0.0001, LV performance index: P = 0.03, stroke volume: P = 0.042), and apical RV-Sl (P = 0.001) improved significantly. The effect of CPAP therapy was related to severity of OSA (LVEF: AHI 5–14, 66.4±8.8%, 68.5±10.6% [P = ns]; AHI 15–30∶59.8±7.7%, 68.6±9.3% [P = 0.002]; AHI>30∶54.1±12.4%, 68.2±13.6%[P<0.0001]; apical RV-Sl: AHI 5–14: −17.3±8.7%, −16.0±10.8% [P = ns], AHI 15–30: −9.8±6.0%, −15.4±10.9% [P = 0.028], AHI>30: −6.3±5.7%, −17.9±11.2% [P<0.0001]). Conclusions OSA seems to have deteriorating effect on LV and RV function. We found a beneficial effect of CPAP on LV and RV functional parameters predominately in patients with severe OSA. 2D speckle tracking might be of value to determine early changes in global and regional right ventricular function. PMID:24146857

  5. Effects of CPAP-therapy on brain electrical activity in obstructive sleep apneic patients: a combined EEG study using LORETA and Omega complexity : reversible alterations of brain activity in OSAS.

    PubMed

    Toth, Marton; Faludi, Bela; Kondakor, Istvan

    2012-10-01

    Effects of initiation of continuous positive airway pressure (CPAP) therapy on EEG background activity were investigated in patients with obstructive sleep apnea syndrome (OSAS, N = 25) to test possible reversibility of alterations of brain electrical activity caused by chronic hypoxia. Normal control group (N = 14) was also examined. Two EEG examinations were done in each groups: at night and in the next morning. Global and regional (left vs. right, anterior vs. posterior) measures of spatial complexity (Omega complexity) were used to characterize the degree of spatial synchrony of EEG. Low resolution electromagnetic tomography (LORETA) was used to localize generators of EEG activity in separate frequency bands. Before CPAP-treatment, a significantly lower Omega complexity was found globally and over the right hemisphere. Due to CPAP-treatment, these significant differences vanished. Significantly decreased Omega complexity was found in the anterior region after treatment. LORETA showed a decreased activity in all of the beta bands after therapy in the right hippocampus, premotor and temporo-parietal cortex, and bilaterally in the precuneus, paracentral and posterior cingulate cortex. No significant changes were seen in control group. Comparing controls and patients before sleep, an increased alpha2 band activity was seen bilaterally in the precuneus, paracentral and posterior cingulate cortex, while in the morning an increased beta3 band activity in the left precentral and bilateral premotor cortex and a decreased delta band activity in the right temporo-parietal cortex and insula were observed. These findings indicate that effect of sleep on EEG background activity is different in OSAS patients and normal controls. In OSAS patients, significant changes lead to a more normal EEG after a night under CPAP-treatment. Compensatory alterations of brain electrical activity in regions associated with influencing sympathetic outflow, visuospatial abilities, long

  6. Efficacy of the New Perilaryngeal Airway (CobraPLA™) Versus the Laryngeal Mask Airway (LMA™) to Improve Oropharyngeal Leak Pressure in Obese and Overweight Patients

    PubMed Central

    Yaghoobi, Siamak; Abootorabi, Seyed Mohamadreza; Kayalha, Hamid; Van Zundert, Tom C

    2015-01-01

    Background: This study aimed to evaluate the applicability of Cobra perilaryngeal airway (Cobra PLA™) for obese patients under general anesthesia and also to compare the results with those of classic laryngeal mask airway (LMA™). Materials and Methods: Seventy-three overweight and obese patients were included in this study. The patients were randomly assigned to LMA™ or Cobra PLA™ groups. Time required for intubation, successful intubation attempt, airway sealing pressure and incidence of complications including blood staining, sore throat and dysphagia were assessed and noted. Results: Thirty-six and 37 patients were randomly allocated to LMA™ and Cobra PLA™ groups, respectively. Most patients were males and had Mallampati Class II airway in both groups. The first attempt and overall insertion success for Cobra PLA™ was significantly higher compared to LMA (P<0.05). Airway insertion was more successful (P = 0.027; 94% vs. 77%) with Cobra PLA™. Insertion times were similar with Cobra PLA™ and LMA™ (Cobra PLA™, 29.94±16.35s; LMA™, 27.00±7.88s). The oropharyngeal leak pressure in the Cobra PLA™ group (24.80±0.90 H2O) was significantly higher than that in LMA™ group (19±1 H2O, p<0.001). Sore throat was more frequent in the LMA™ group although it did not reach statistical significance (Fisher’s exact test, P = 0.33). Blood staining on airway tube was seen in both groups with a higher incidence in the Cobra PLA™ group (Fisher’s Exact test, P = 0.02). Incidence of dysphagia was not different between the two groups. Conclusion: CobraPLA™ was found to be safe with low complications. It provided better airway sealing with high rate of the first insertion success for use in obese and overweight patients. This study recommends the use of CobraPLA™ as a rescue device in emergency situations for obese and overweight patients. PMID:26221151

  7. Negative Expiratory Pressure Technique: An Awake Test to Measure Upper Airway Collapsibility in Adolescents

    PubMed Central

    Carrera, Helena Larramona; Marcus, Carole L.; McDonough, Joseph M.; Morera, Joan C. Oliva; Huang, Jingtao; Farre, Ramon; Montserrat, Josep M.

    2015-01-01

    Study Objectives: Upper airway (UA) collapsibility is a major pathophysiologic feature of the obstructive sleep apnea syndrome (OSAS). In adolescents, it is measured by obtaining the slope of pressure-flow relationship (SPF) while applying negative nasal pressure during sleep. An easier technique to assess UA collapsibility, consisting of application of negative expiratory pressure (NEP) during wakefulness, has demonstrated differences between control and OSAS subjects. We hypothesized that the NEP technique would correlate with SPF as a measurement of UA collapsibility in adolescents. Design: During wakefulness, NEP of −5 cm H2O in the seated and supine position was applied during the first second of expiration. The area under the expiratory flow-volume curve during NEP was compared to tidal breathing (RatioNEP). In addition, adolescents underwent SPF measurements during sleep. Two SPF techniques were performed to measure the activated and relatively hypotonic UA. Setting: Pediatric sleep laboratory. Participants: Seven adolescents with OSAS and 20 controls. Results: In the seated position, there was a correlation between RatioNEP and both hypotonic SPF (r = −0.39, P = 0.04) and activated SPF (r = −0.62, P = 0.001). In the supine position, there was a correlation between RatioNEP and activated SPF (r = −0.43, P = 0.03) and a trend for hypotonic SPF (r = −0.38, P = 0.06). Conclusions: The negative expiratory pressure (NEP) technique correlates with the hypotonic and activated slope of pressure-flow relationship measurements. The seated position showed the strongest correlation. The NEP technique can be used as an alternative method to evaluate upper airway collapsibility in adolescents. Citation: Carrera HL, Marcus CL, McDonough JM, Morera JC, Huang J, Farre R, Montserrat JM. Negative expiratory pressure technique: an awake test to measure upper airway collapsibility in adolescents. SLEEP 2015;38(11):1783–1791. PMID:26158888

  8. Use of Biphasic Continuous Positive Airway Pressure in Premature Infant with Cleft Lip–Cleft Palate

    PubMed Central

    George, Lovya; Jain, Sunil K.

    2015-01-01

    Preterm infants (PIs) often require respiratory support due to surfactant deficiency. Early weaning from mechanical ventilation to noninvasive respiratory support decreases ventilation-associated irreversible lung damage. This wean is particularly challenging in PIs with cleft lip and cleft palate due to anatomical difficulties encountered in maintaining an adequate seal for positive pressure ventilation. PI with a cleft lip and palate often fail noninvasive respiratory support and require continued intubation and mechanical ventilation. We are presenting the first case report of a PI with cleft lip and palate who was managed by biphasic nasal continuous positive airway pressure. PMID:26495158

  9. Mandibular Advancing Positive Pressure Apnea Remediation Device (MAPPARD)

    DTIC Science & Technology

    2014-06-01

    wiki/Starling_resistor Lankford, D. A., Proctor, C. D., & Richard, R. (2005). Continuous positive airway pressure (CPAP) changes in bariatric surgery ...Mandibular Advancing Device (after Schlaflabor-Saletu, n.d.). ............ 8  Figure 4.  Uvulopalatopharyngoplasty (before and after surgery ) (from...Lastly, when behavioral and medical techniques have been exhausted the last OSA reduction technique is surgery . Within the last 25 years, the

  10. Impact of CPAP on Activity Patterns and Diet in Patients with Obstructive Sleep Apnea (OSA)

    PubMed Central

    Batool-Anwar, Salma; Goodwin, James L.; Drescher, Amy A.; Baldwin, Carol M.; Simon, Richard D.; Smith, Terry W.; Quan, Stuart F.

    2014-01-01

    Study Objectives: Patients with severe OSA consume greater amounts of cholesterol, protein, and fat as well as have greater caloric expenditure. However, it is not known whether their activity levels or diet change after treatment with CPAP. To investigate this issue, serial assessments of activity and dietary intake were performed in the Apnea Positive Pressure Long-term Efficacy Study (APPLES); a 6-month randomized controlled study of CPAP vs. sham CPAP on neurocognitive outcomes. Methods: Subjects were recruited into APPLES at 5 sites through clinic encounters or public advertisement. After undergoing a diagnostic polysomnogram, subjects were randomized to CPAP or sham if their AHI was ≥ 10. Adherence was assessed using data cards from the devices. At the Tucson and Walla Walla sites, subjects were asked to complete validated activity and food frequency questionnaires at baseline and their 4-month visit. Results: Activity and diet data were available at baseline and after 4 months treatment with CPAP or sham in up to 231 subjects (117 CPAP, 114 Sham). Mean age, AHI, BMI, and Epworth Sleepiness Score (ESS) for this cohort were 55 ± 13 [SD] years, 44 ± 27 /h, 33 ± 7.8 kg/m2, and 10 ± 4, respectively. The participants lacking activity and diet data were younger, had lower AHI and arousal index, and had better sleep efficiency (p < 0.05). The BMI was higher among women in both CPAP and Sham groups. However, compared to women, men had higher AHI only in the CPAP group (50 vs. 34). Similarly, the arousal index was higher among men in CPAP group. Level of adherence defined as hours of device usage per night at 4 months was significantly higher among men in CPAP group (4.0 ± 2.9 vs. 2.6 ± 2.6). No changes in consumption of total calories, protein, carbohydrate or fat were noted after 4 months. Except for a modest increase in recreational activity in women (268 ± 85 vs. 170 ± 47 calories, p < 0.05), there also were no changes in activity patterns. Conclusion

  11. Diastolic function and functional capacity after a single session of continuous positive airway pressure in patients with compensated heart failure

    PubMed Central

    Bussoni, Marjory Fernanda; Guirado, Gabriel Negretti; Matsubara, Luiz Shiguero; Roscani, Meliza Goi; Polegato, Bertha Furlan; Minamoto, Suzana Tanni; Bazan, Silméia Garcia Zanati; Matsubara, Beatriz Bojikian

    2014-01-01

    OBJECTIVE: The effects of acute continuous positive airway pressure therapy on left ventricular diastolic function and functional capacity in patients with compensated systolic heart failure remain unclear. METHODS: This randomized, double-blind, placebo-controlled clinical trial included 43 patients with heart failure and a left ventricular ejection fraction <0.50 who were in functional classes I-III according to the New York Heart Association criteria. Twenty-three patients were assigned to continuous positive airway pressure therapy (10 cmH2O), while 20 patients received placebo with null pressure for 30 minutes. All patients underwent a 6-minute walk test (6MWT) and Doppler echocardiography before and immediately after intervention. Clinicaltrials.gov: NCT01088854. RESULTS: The groups had similar clinical and echocardiographic baseline variables. Variation in the diastolic function index (e′) after intervention was associated with differences in the distance walked in both groups. However, in the continuous positive airway pressure group, this difference was greater (continuous positive airway pressure group: Δ6MWT = 9.44+16.05×Δe′, p = 0.002; sham group: Δ6MWT = 7.49+5.38×Δe′; p = 0.015). There was a statistically significant interaction between e′ index variation and continuous positive airway pressure for the improvement of functional capacity (p = 0.020). CONCLUSIONS: Continuous positive airway pressure does not acurately change the echocardiographic indexes of left ventricle systolic or diastolic function in patients with compensated systolic heart failure. However, 30-minute continuous positive airway pressure therapy appears to have an effect on left ventricular diastolic function by increasing functional capacity. PMID:24838902

  12. Oscillatory pressure wave transmission from the upper airway to the carotid artery.

    PubMed

    Howitt, Lauren; Kairaitis, Kristina; Kirkness, Jason P; Garlick, Sarah R; Wheatley, John R; Byth, Karen; Amis, Terence C

    2007-11-01

    Snoring-associated vibration energy transmission from the upper airway to the carotid artery has been hypothesized as a potential atherosclerotic plaque initiating/rupturing event that may provide a pathogenic mechanism linking snoring and embolic stroke. We examined transmission of oscillatory pressure waves from the pharyngeal lumen to the common carotid artery wall and lumen in seven male, anesthetized, spontaneously breathing New Zealand White rabbits. Airflow was monitored via a pneumotachograph inserted in series in the intact trachea. Fifteen 20-s runs of, separately, 40-, 60-, and 90-Hz oscillatory pressure waves [pressure amplitude in the trachea (Ptr(amp)), amplitude 2-20 cmH(2)O] were generated by a loudspeaker driven by a sine wave generator and amplifier and superimposed on tidal breathing via the cranial tracheal connector. Pressure transducer-tipped catheters measured pressure amplitudes in the tissues adjacent to the common carotid artery bifurcation (Pcti(amp)) and within the lumen (carotid sinus; Pcs(amp)). Data were analyzed using power spectrum analysis and linear mixed-effects statistical modeling. Both the frequency (f) and amplitude of the injected pressure wave influenced Pcti(amp) and Pcs(amp), in that ln Pcti(amp) = 1.2(Ptr(amp)) + 0.02(f) - 5.2, and ln Pcs(amp) = 0.6(Ptr(amp)) + 0.02(f) - 4.9 (both P < 0.05). Across all frequencies tested, transfer of oscillatory pressure across the carotid artery wall was associated with an amplitude gain, as expressed by a Pcs(amp)-to-Pcti(amp) ratio of 1.8 +/- 0.3 (n = 6). Our findings confirm transmission of oscillatory pressure waves from the upper airway lumen to the peripharyngeal tissues and across the carotid artery wall to the lumen. Further studies are required to establish the role of this incident energy in the pathogenesis of carotid artery vascular disease.

  13. Bubble continuous positive airway pressure in a human immunodeficiency virus-infected infant

    PubMed Central

    McCollum, E. D.; Smith, A.; Golitko, C. L.

    2014-01-01

    SUMMARY World Health Organization-classified very severe pneumonia due to Pneumocystis jirovecii infection is recognized as a life-threatening condition in human immunodeficiency virus (HIV) infected infants. We recount the use of nasal bubble continuous positive airway pressure (BCPAP) in an HIV-infected African infant with very severe pneumonia and treatment failure due to suspected infection with P. jirovecii. We also examine the potential implications of BCPAP use in resource-poor settings with a high case index of acute respiratory failure due to HIV-related pneumonia, but limited access to mechanical ventilation. PMID:21396221

  14. [Obstruction of the upper airways in humans and animal models].

    PubMed

    Schulz, R

    2010-07-01

    Obstructive sleep apnea (OSA) is caused by repetitive collapse of a narrow upper airway during sleep with the main risk factor being obesity. Apneas are followed by hypoxia, sympathetic activation, intrathoracic pressure swings and arousals. In most animal studies, only the cyclical pattern of hypoxia characteristic of OSA is simulated, however, more complex models have also been developed which additionally reflect the other pathophysiological changes associated with sleep-disordered breathing. These models have contributed to a deeper understanding of the cardiovascular and metabolic consequences of OSA. From other experiments the concept of the pharynx behaving like a collapsible tube, i. e. a Starling resistor, has emerged. Finally, the neurotransmitter modulation of upper airway muscle tone has been elucidated by using IN VIVO microdialysis of the caudal medulla of rats. It is hoped that findings from animal studies will in the future impact on the management of patients with OSA, in particular if they are non-compliant with CPAP therapy.

  15. Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients

    PubMed Central

    Palomero-Rodríguez, Miguel Angel; de Arteaga, Héctor Chozas; Báez, Yolanda Laporta; de Vicente Sánchez, Jesús; Carretero, Pascual Sanabria; Conde, Pilar Sánchez; Pérez Ferrer, Antonio

    2016-01-01

    Background: Over the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants (“Mapleson D CPAP system”). The primary goal of this study was to assess the usefulness of the “Mapleson D CPAP system” for weaning of mechanical ventilation (MV) in infants who received MV over 24 h. Materials and Methods: All infants who received MV for more than 24 h in the last year were enrolled in the study. Demographic data included age, gender, weight, and admission diagnosis. Heart rate, respiratory rate, blood pressure, and oxygen saturation were measured during MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation. Patients were classified into two groups: patients MV more than 48 h, and patients with MV fewer than 48 h. P < 0.05 was considered statistically significant. Results: A total of 50 children were enrolled in the study, with a median age was 34 ± 45 months (range, 1–59 months) and median weight was 11.98 ± 9.31 kg (range, 1–48 kg). Median duration of MV was 480 h (range, 2–570). There were no significant differences in PaO2, PaCO2, and pH among MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation and spontaneous ventilation with the nasopharyngeal Mapleson D CPAP system or with nasal prongs. The overall extubation failure rate was 26% (n = 13). Weight and age were significantly associated with extubation failure (P < 0.05). Conclusions: The Mapleson D CPAP system, in our opinion, is a useful and safe alternative to more complex and expensive noninvasive CPAP and BiPAP weaning from MV in infants. PMID:27625446

  16. Computer simulations of pressure and velocity fields in a human upper airway during sneezing.

    PubMed

    Rahiminejad, Mohammad; Haghighi, Abdalrahman; Dastan, Alireza; Abouali, Omid; Farid, Mehrdad; Ahmadi, Goodarz

    2016-04-01

    In this paper, the airflow field including the velocity, pressure and turbulence intensity distributions during sneezing of a female subject was simulated using a computational fluid dynamics model of realistic upper airways including both oral and nasal cavities. The effects of variation of reaction of the subject during sneezing were also investigated. That is, the impacts of holding the nose or closing the mouth during sneezing on the pressure and velocity distributions were studied. Few works have studied the sneeze and therefore different aspects of this phenomenon have remained unknown. To cover more possibilities about the inlet condition of trachea in different sneeze scenarios, it was assumed that the suppressed sneeze happens with either the same inlet pressure or the same flow rate as the normal sneeze. The simulation results showed that during a normal sneeze, the pressure in the trachea reaches about 7000Pa, which is much higher than the pressure level of about 200Pa during the high activity exhalation. In addition, the results showed that, suppressing the sneeze by holding the nose or mouth leads to a noticeable increase in pressure difference in the tract. This increase was about 5 to 24 times of that during a normal sneeze. This significant rise in the pressure can justify some reported damage due to suppressing a sneeze.

  17. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway

    PubMed Central

    Grams, Samantha Torres; Kimoto, Karen Yumi Mota; Azevedo, Elen Moda de Oliveira; Lança, Marina; de Albuquerque, André Luis Pereira; de Brito, Christina May Moran; Yamaguti, Wellington Pereira

    2015-01-01

    Introduction Maximal Inspiratory Pressure (MIP) is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway. Objectives This study aimed to compare the MIP values assessed by standard method (MIPsta) and by unidirectional expiratory valve method (MIPuni) in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated. Methods This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B) at two moments (Tests 1 and 2) to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1]) was used to determine intraobserver and interobserver reproducibility. Results The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O) than the mean values for MIPsta (-102.5 ± 23.9 cmH2O) (p<0.001). Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91), and high correlation for Test 2 (ICC[2,1] = 0.88). The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86) and evaluator B (ICC[2,1] = 0.77). Conclusions MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway. PMID:26360255

  18. Treatment of upper airway resistance syndrome in adults: Where do we stand?☆

    PubMed Central

    de Godoy, Luciana B.M.; Palombini, Luciana O.; Guilleminault, Christian; Poyares, Dalva; Tufik, Sergio; Togeiro, Sonia M.

    2015-01-01

    Objective: To evaluate the available literature regarding Upper Airway Resistance Syndrome (UARS) treatment. Methods: Keywords “Upper Airway Resistance Syndrome,” “Sleep-related Breathing Disorder treatment,” “Obstructive Sleep Apnea treatment” and “flow limitation and sleep” were used in main databases. Results: We found 27 articles describing UARS treatment. Nasal continuous positive airway pressure (CPAP) has been the mainstay therapy prescribed but with limited effectiveness. Studies about surgical treatments had methodological limitations. Oral appliances seem to be effective but their efficacy is not yet established. Conclusion: Randomized controlled trials with larger numbers of patients and long-term follow-up are important to establish UARS treatment options. PMID:26483942

  19. Effects of Altered Intra-abdominal Pressure on the Upper Airway Collapsibility in a Porcine Model

    PubMed Central

    Ren, Shu-Lin; Li, Yan-Ru; Wu, Ji-Xiang; Ye, Jing-Ying; Jen, Rachel

    2015-01-01

    Background: Obstructive sleep apnea is strongly associated with obesity, particularly abdominal obesity common in centrally obese males. Previous studies have demonstrated that intra-abdominal pressure (IAP) is increased in morbid obesity, and tracheal traction forces may influence pharyngeal airway collapsibility. This study aimed to investigate that whether IAP plays a role in the mechanism of upper airway (UA) collapsibility via IAP-related caudal tracheal traction. Methods: An abdominal wall lifting (AWL) system and graded CO2 pneumoperitoneum pressure was applied to four supine, anesthetized Guizhou miniature pigs and its effects on tracheal displacement (TD) and airflow dynamics of UA were studied. Individual run data in 3 min obtained before and after AWL and obtained before and after graded pneumoperitoneum pressure were analyzed. Differences between baseline and AWL/graded pneumoperitoneum pressure data of each pig were examined using a Student's t-test or analysis of variance. Results: Application of AWL resulted in decreased IAP and significant caudal TD. The average displacement amplitude was 0.44 mm (P < 0.001). There were three subjects showed increased tidal volume (TV) (P < 0.01) and peak inspiratory airflow (P < 0.01); however, the change of flow limitation inspiratory UA resistance (Rua) was not significant. Experimental increased IAP by pneumoperitoneum resulted in significant cranial TD. The average displacement amplitude was 1.07 mm (P < 0.001) when IAP was 25 cmH2O compared to baseline. There were three subjects showed reduced Rua while the TV increased (P < 0.01). There was one subject had decreased TV and elevated Rua (P < 0.001). Conclusions: Decreased IAP significantly increased caudal TD, and elevated IAP significantly increased cranial TD. However, the mechanism of UA collapsibility appears primarily mediated by changes in lung volume rather than tracheal traction effect. TV plays an independent role in the mechanism of UA collapsibility

  20. Impact of adherence with positive airway pressure therapy on hypercapnia in obstructive sleep apnea

    PubMed Central

    Mokhlesi, Babak; Tulaimat, Aiman; Evans, Arthur T.; Wang, Yue; Itani, Abed-Alrahman; Hassaballa, Hesham A.; Herdegen, James J.; Stepanski, Edward J.

    2007-01-01

    Background Daytime hypercapnia associated with obstructive sleep apnea is common, particularly in the severely obese, and is associated with serious complications. Although positive airway pressure therapy improves daytime hypercapnia, the magnitude of benefit is unknown. Our objective was to quantify the effect of adherence with positive airway pressure on hypercapnia and hypoxia and to identify other factors that predict changes in PaCO2 and PaO2. Methods We performed a retrospective cohort study of seventy-five patients using a multivariable general linear model analysis to identify variables that predicted changes in PaCO2 and PaO2 after therapy. Bootstrap resampling methods were used to calculate confidence intervals for the effects of significant predictors and to internally validate the predictive models. Results The variables that predicted the change in PaCO2 were: average daily hours of positive pressure therapy, FEV1% of predicted, and baseline PaCO2 (model R2 = 0.70). The PaCO2 dropped 1.84 mm Hg per hour of adherence and plateaued at 7 hours of average daily use. PaO2 improved by approximately 3 mm Hg per hour of adherence and plateaued after 4.5 hours of therapy (model R2 = 0.48). Patients who used therapy for more than 4.5 hours per day experienced significant improvements in PaCO2 and PaO2 compared to less adherent patients (ΔPaCO2 7.7±5 vs. 2.4±4 mm Hg, p<0.001; ΔPaO2 9.2±11 vs. 1.8±9 mm Hg, p<0.001). For adherent patients, the need for daytime home oxygen therapy decreased from 30% to 6% (p=0.02). Conclusion In hypercapnic patients with obstructive sleep apnea, adherence with positive airway pressure is an important modifiable predictor of improvements in PaCO2 and PaO2, and its benefit plateaus between 5 to 7 hours of daily therapy. PMID:17557438

  1. Predictors of Positive Airway Pressure Therapy Adherence in Children: A Prospective Study

    PubMed Central

    DiFeo, Natalie; Meltzer, Lisa J.; Beck, Suzanne E.; Karamessinis, Laurie R.; Cornaglia, Mary Anne; Traylor, Joel; Samuel, John; Gallagher, Paul R.; Radcliffe, Jerilynn; Beris, Heidi; Menello, Mary Kate; Marcus, Carole L.

    2012-01-01

    Study Objectives: Children with obstructive sleep apnea are increasingly being treated with positive airway pressure (PAP), particularly if they have underlying medical conditions. Although PAP is an effective treatment, its use is challenging due to poor adherence. We hypothesized that demographic, psychosocial, and polysomnographic parameters would be related to PAP adherence. We therefore prospectively collected data potentially pertaining to PAP adherence, and correlated it with PAP use. Methods: Fifty-six patients and their parents completed a series of psychosocial questionnaires prior to PAP initiation. Objective adherence data were obtained after 1 and 3 months of PAP use. Results: The population was primarily obese; 23% had neurodevelopmental disabilities. PAP adherence varied widely, with PAP being worn 22 ± 8 nights in month-1, but mean use was only 3 ± 3 h/night. The greatest predictor of use was maternal education (p = 0.002 for nights used; p = 0.033 for mean h used/night). Adherence was lower in African American children vs other races (p = 0.021). In the typically developing subgroup, adherence correlated inversely with age. Adherence did not correlate with severity of apnea, pressure levels, or psychosocial parameters other than a correlation between family social support and nights of PAP use in month-3. Conclusions: PAP adherence in children and adolescents is related primarily to family and demographic factors rather than severity of apnea or measures of psychosocial functioning. Further research is needed to determine the relative contributions of maternal education, socioeconomic status and cultural beliefs to PAP adherence in children, in order to develop better adherence programs. Citation: DiFeo N; Meltzer LJ; Beck SE; Karamessinis LR; Cornaglia MA; Traylor J; Samuel J; Gallagher PR; Radcliffe J; Beris H; Menello MK; Marcus CL. Predictors of positive airway pressure therapy adherence in children: a prospective study. J Clin Sleep Med 2012

  2. Evaluation of a humidified nasal high-flow oxygen system, using oxygraphy, capnography and measurement of upper airway pressures.

    PubMed

    Ritchie, J E; Williams, A B; Gerard, C; Hockey, H

    2011-11-01

    In this study, we evaluated the performance of a humidified nasal high-flow system (Optiflow, Fisher and Paykel Healthcare) by measuring delivered FiO, and airway pressures. Oxygraphy, capnography and measurement of airway pressures were performed through a hypopharyngeal catheter in healthy volunteers receiving Optiflow humidified nasal high flow therapy at rest and with exercise. The study was conducted in a non-clinical experimental setting. Ten healthy volunteers completed the study after giving informed written consent. Participants received a delivered oxygen fraction of 0.60 with gas flow rates of 10, 20, 30, 40 and 50 l/minute in random order FiO2, F(E)O2, F(E)CO2 and airway pressures were measured. Calculation of FiO2 from F(E)O2 and F(E)CO2 was later performed. Calculated FiO2 approached 0.60 as gas flow rates increased above 30 l/minute during nose breathing at rest. High peak inspiratory flow rates with exercise were associated with increased air entrainment. Hypopharyngeal pressure increased with increasing delivered gas flow rate. At 50 l/minute the system delivered a mean airway pressure of up to 7.1 cm H20. We believe that the high gas flow rates delivered by this system enable an accurate inspired oxygen fraction to be delivered. The positive mean airway pressure created by the high flow increases the efficacy of this system and may serve as a bridge to formal positive pressure systems.

  3. Commercial Motor Vehicle Driver Positive Airway Pressure Therapy Adherence in a Sleep Center

    PubMed Central

    Colvin, Loretta J.; Dace, Gayla A.; Colvin, Ryan M.; Ojile, Joseph; Collop, Nancy

    2016-01-01

    Study Objectives: To assess positive airway pressure (PAP) therapy adherence in commercial motor vehicle (CMV) drivers presenting to a sleep center. Methods: A retrospective chart review of 120 drivers evaluated for obstructive sleep apnea OSA and 53 initiated on PAP therapy in a single sleep center over a one-year period (2012); PAP therapy data were collected up to 1 year. Results: Early PAP usage best predicted adherence up to 1 year (p < 0.0001) compared to patient factors, OSA disease characteristics, and treatment elements analyzed. The proportion of participants adherent to therapy was 68.0% at 1 week, decreasing to 39.6% at 1 year, with 31.1% lost to follow-up by 1 year. In the group categorized based on adherence at week 1, 80.6% were adherent at 1 month, decreasing to 52.8% at 1 year. For the group non-adherent at 1 week, 29.4% were adherent at 1 month, decreasing to 11.7% at 1 year. Participants were predominantly male (75.8%), middle-aged (median 50.5 years), and African American (71.7%). Of those referred to the sleep center, 86.7% had OSA (median apnea-hypopnea index [AHI] or respiratory event index [REI] 20.1), with 51.0% of the OSA group having an AHI or REI > 20 and initiating PAP therapy. Conclusions: Early PAP utilization patterns predicted one year adherence for our CMV driver population within a sleep clinic setting. OSA testing of these CMV drivers after occupational health referral identifies high proportions of undiagnosed OSA, with approximately half requiring PAP therapy based on current published treatment recommendations. Citation: Colvin LJ, Dace GA, Colvin RM, Ojile J, Collop N. Commercial motor vehicle driver positive airway pressure therapy adherence in a sleep center. J Clin Sleep Med 2016;12(4):477–485. PMID:26715403

  4. Genioglossus reflex inhibition to upper-airway negative-pressure stimuli during wakefulness and sleep in healthy males

    PubMed Central

    Eckert, Danny J; McEvoy, R Doug; George, Kate E; Thomson, Kieron J; Catcheside, Peter G

    2007-01-01

    During wakefulness, obstructive sleep apnoea patients appear to compensate for an anatomically narrow upper airway by increasing upper airway dilator muscle activity, e.g. genioglossus, at least partly via a negative-pressure reflex that may be diminished in sleep. Previous studies have assessed the negative-pressure reflex using multi-unit, rectified, moving-time-average EMG recordings during brief pulses of negative upper-airway pressure. However, moving-time averaging probably obscures the true time-related reflex morphology, potentially masking transient excitatory and inhibitory components. This study aimed to re-examine the genioglossus negative-pressure reflex in detail, without moving-time averaging. Bipolar fine-wire electrodes were inserted per orally into the genioglossus muscle in 17 healthy subjects. Two upper airway pressure catheters were inserted per nasally. Genioglossus EMG reflex responses were generated via negative-pressure stimuli (∼−10 cmH2O at the choanae, 250 ms duration) delivered during wakefulness and sleep. Ensemble-averaged, rectified, genioglossus EMG recordings demonstrated reflex activation (onset latency 26 ± 1 ms; peak amplitude 231 ± 29% of baseline) followed by a previously unreported suppression (peak latency 71 ± 4 ms; 67 ± 8% of baseline). Single-motor-unit activity, clearly identifiable in ∼10% of trials in six subjects, showed a concomitant increase in the interspike interval from baseline (26 ± 9 ms, P = 0.01). Genioglossus negative-pressure reflex morphology and amplitude of the initial peak were maintained in non-rapid eye movement (NREM) sleep but suppression amplitude was more pronounced during NREM and declined further during REM sleep compared to wakefulness. These data indicate there are both excitatory and inhibitory components to the genioglossus negative-pressure reflex which are differentially affected by state. PMID:17395627

  5. The relationship between early reversibility test and maximal inspiratory pressure in patients with airway obstruction.

    PubMed

    Ozkaya, Sevket; Dirican, Adem; Kaya, Sule Ozbay; Karanfil, Rabia C; Bayrak, Merve G; Bostancı, Ozgür; Ece, Ferah

    2014-01-01

    Maximal inspiratory pressure (MIP) is a marker for assessing the degree of respiratory muscle dysfunction. Muscle dysfunction represents a pathophysiological feature of chronic obstructive pulmonary disease. We aimed to determinate the MIP value in patients with airway obstruction, to evaluate the change in MIP with bronchodilator drug, and to show the relationship between the changes in MIP and disease characteristics. We evaluated 21 patients with airway obstruction at the Department of Pulmonary Medicine, Samsun Medicalpark Hospital, Samsun, Turkey. We performed pulmonary function tests, measurement of MIP values, and reversibility tests with salbutamol. The baseline spirometry results were: mean forced vital capacity (FVC), 3,017±1,020 mL and 75.8%±20.8%; mean forced expiratory volume in 1 second (FEV1), 1,892±701 mL and 59.2%±18.2%; FEV1/FVC, 62.9%±5.5%; peak expiratory flow, 53%±19%. The pre-bronchodilator MIP value was 62.1±36.9 cmH2O. The reversibility test was found to be positive in 61.9% of patients with salbutamol. The absolute change and percentage of change in FEV1 were 318±223 mL and 19.8%±16.7%, respectively. The MIP value was increased by 5.5 cmH2O (8.8%) and was 67.7±30.3 cmH2O after bronchodilation. There was no significant relationship between age, FEV1, reversibility, and change in MIP with bronchodilator. However, the increase in MIP with bronchodilator drug was higher in patients with low body mass index (<25 kg/m(2)). We noted a 13.1% increase in FVC, a 19.8% increase in FEV1, a 20.2% increase in peak expiratory flow, and an 8.8% increase in MIP with salbutamol. In conclusion; MIP increases with bronchodilator therapy, regardless of changes in lung function, in patients with airway obstruction. The reversibilty test can be used to evaluate change in MIP with salbutamol.

  6. Dynamic airway pressure-time curve profile (Stress Index): a systematic review.

    PubMed

    Terragni, Pierpaolo; Bussone, Guido; Mascia, Luciana

    2016-01-01

    The assessment of respiratory mechanics at the bedside is necessary in order to identify the most protective ventilatory strategy. Indeed in the last 20 years, adverse effects of positive ventilation to the lung structures have led to a reappraisal of the objectives of mechanical ventilation. The ventilator setting requires repeated readjustment over the period of mechanical ventilation dependency and careful respiratory monitoring to minimize the risks, preventing further injury and permitting the lung and airways healing. Among the different methods that have been proposed and validated, the analysis of dynamic P-t curve (named Stress Index, SI) represents an adequate tool available at the bedside, repeatable and, therefore, able to identify the amount of overdistension occurring in the daily clinical practice, when modifying positive end-expiratory pressure. In this review we will analyze the evidence that supports respiratory mechanics assessment at the bedside and the application of the dynamic P/t curve profile (SI) to optimize protective ventilation in patients with acute respiratory failure.

  7. Positive airway pressure improves nocturnal beat-to-beat blood pressure surges in obesity hypoventilation syndrome with obstructive sleep apnea.

    PubMed

    Carter, Jason R; Fonkoue, Ida T; Grimaldi, Daniela; Emami, Leila; Gozal, David; Sullivan, Colin E; Mokhlesi, Babak

    2016-04-01

    Positive airway pressure (PAP) treatment has been shown to have a modest effect on ambulatory blood pressure (BP) in patients with obstructive sleep apnea (OSA). However, there is a paucity of data on the effect of PAP therapy on rapid, yet significant, BP swings during sleep, particularly in obesity hypoventilation syndrome (OHS). The present study hypothesizes that PAP therapy will improve nocturnal BP on the first treatment night (titration PAP) in OHS patients with underlying OSA, and that these improvements will become more significant with 6 wk of PAP therapy. Seventeen adults (7 men, 10 women; age 50.4 ± 10.7 years, BMI 49.3 ± 2.4 kg/m(2)) with OHS and clinically diagnosed OSA participated in three overnight laboratory visits that included polysomnography and beat-to-beat BP monitoring via finger plethysmography. Six weeks of PAP therapy, but not titration PAP, lowered mean nocturnal BP. In contrast, when nocturnal beat-to-beat BPs were aggregated into bins consisting of at least three consecutive cardiac cycles with a >10 mmHg BP surge (i.e., Δ10-20, Δ20-30, Δ30-40, and Δ>40 mmHg), titration, and 6-wk PAP reduced the number of BP surges per hour (time × bin, P < 0.05). PAP adherence over the 6-wk period was significantly correlated to reductions in nocturnal systolic (r = 0.713, P = 0.001) and diastolic (r = 0.497, P = 0.043) BP surges. Despite these PAP-induced improvements in nocturnal beat-to-beat BP surges, 6 wk of PAP therapy did not alter daytime BP. In conclusion, PAP treatment reduces nocturnal beat-to-beat BP surges in OHS patients with underlying OSA, and this improvement in nocturnal BP regulation was greater in patients with higher PAP adherence.

  8. Oronasal Masks Require a Higher Pressure than Nasal and Nasal Pillow Masks for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Deshpande, Sheetal; Joosten, Simon; Turton, Anthony; Edwards, Bradley A.; Landry, Shane; Mansfield, Darren R.; Hamilton, Garun S.

    2016-01-01

    Study Objectives: Oronasal masks are frequently used for continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA). The aim of this study was to (1) determine if CPAP requirements are higher for oronasal masks compared to nasal mask interfaces and (2) assess whether polysomnography and patient characteristics differed among mask preference groups. Methods: Retrospective analysis of all CPAP implementation polysomnograms between July 2013 and June 2014. Prescribed CPAP level, polysomnography results and patient data were compared according to mask type (n = 358). Results: Oronasal masks were used in 46%, nasal masks in 35% and nasal pillow masks in 19%. There was no difference according to mask type for baseline apnea-hypopnea index (AHI), body mass index (BMI), waist or neck circumference. CPAP level was higher for oronasal masks, 12 (10–15.5) cm H2O compared to nasal pillow masks, 11 (8–12.5) cm H2O and nasal masks, 10 (8–12) cm H2O, p < 0.0001 (Median [interquartile range]). Oronasal mask type, AHI, age, and BMI were independent predictors of a higher CPAP pressure (p < 0.0005, adjusted R2 = 0.26.). For patients with CPAP ≥ 15 cm H2O, there was an odds ratio of 4.5 (95% CI 2.5–8.0) for having an oronasal compared to a nasal or nasal pillow mask. Residual median AHI was higher for oronasal masks (11.3 events/h) than for nasal masks (6.4 events/h) and nasal pillows (6.7 events/h), p < 0.001. Conclusions: Compared to nasal mask types, oronasal masks are associated with higher CPAP pressures (particularly pressures ≥ 15 cm H2O) and a higher residual AHI. Further evaluation with a randomized control trial is required to definitively establish the effect of mask type on pressure requirements. Commentary: A commentary on this article appears in this issue on page 1209. Citation: Deshpande S, Joosten S, Turton A, Edwards BA, Landry S, Mansfield DR, Hamilton GS. Oronasal masks require a higher pressure than nasal and

  9. The influence of gender and upper airway resistance on the ventilatory response to arousal in obstructive sleep apnoea in humans

    PubMed Central

    Jordan, Amy S; McEvoy, R Doug; Edwards, Jill K; Schory, Karen; Yang, Chang-Kook; Catcheside, Peter G; Fogel, Robert B; Malhotra, Atul; White, David P

    2004-01-01

    The termination of obstructive respiratory events is typically associated with arousal from sleep. The ventilatory response to arousal may be an important determinant of subsequent respiratory stability/instability and therefore may be involved in perpetuating obstructive respiratory events. In healthy subjects arousal is associated with brief hyperventilation followed by more prolonged hypoventilation on return to sleep. This study was designed to assess whether elevated sleeping upper airway resistance (RUA) alters the ventilatory response to arousal and subsequent breathing on return to sleep in patients with obstructive sleep apnoea (OSA). Inspired minute ventilation (VI), RUA and end-tidal CO2 pressure (PET,CO2) were measured in 22 patients (11 men, 11 women) with OSA (mean ±s.e.m., apnoea–hypopnoea index (AHI) 48.9 ± 5.9 events h−1) during non-rapid eye movement (NREM) sleep with low RUA (2.8 ± 0.3 cmH2O l−1 s; optimal continuous positive airway pressure (CPAP) = 11.3 ± 0.7 cmH2O) and with elevated RUA (17.6 ± 2.8 cmH2O l−1 s; sub-optimal CPAP = 8.4 ± 0.8 cmH2O). A single observer, unaware of respiratory data, identified spontaneous and tone-induced arousals of 3–15 s duration preceded and followed by stable NREM sleep. VI was compared between CPAP levels before and after spontaneous arousal in 16 subjects with tone-induced arousals in both conditions. During stable NREM sleep at sub-optimal CPAP, PET,CO2 was mildly elevated (43.5 ± 0.8 versus 42.5 ± 0.8 Torr). However, baseline VI (7.8 ± 0.3 versus 8.0 ± 0.3 l min−1) was unchanged between CPAP conditions. For the first three breaths following arousal, VI was higher for sub-optimal than optimal CPAP (first breath: 11.2 ± 0.9 versus 9.3 ± 0.6 l min−1). The magnitude of hypoventilation on return to sleep was not affected by the level of CPAP and both obstructive and central respiratory events were rare following arousal. Similar results occurred after tone-induced arousals which led to

  10. Physiological Correlation of Airway Pressure and Transpulmonary Pressure Stress Index on Respiratory Mechanics in Acute Respiratory Failure

    PubMed Central

    Pan, Chun; Chen, Lu; Zhang, Yun-Hang; Liu, Wei; Urbino, Rosario; Ranieri, V Marco; Qiu, Hai-Bo; Yang, Yi

    2016-01-01

    Background: Stress index at post-recruitment maneuvers could be a method of positive end-expiratory pressure (PEEP) titration in acute respiratory distress syndrome (ARDS) patients. However, airway pressure (Paw) stress index may not reflect lung mechanics in the patients with high chest wall elastance. This study was to evaluate the Paw stress index on lung mechanics and the correlation between Paw stress index and transpulmonary pressure (PL) stress index in acute respiratory failure (ARF) patients. Methods: Twenty-four ARF patients with mechanical ventilation (MV) were consecutively recruited from July 2011 to April 2013 in Zhongda Hospital, Nanjing, China and Ospedale S. Giovanni Battista-Molinette Hospital, Turin, Italy. All patients underwent MV with volume control (tidal volume 6 ml/kg) for 20 min. PEEP was set according to the ARDSnet study protocol. The patients were divided into two groups according to the chest wall elastance/respiratory system elastance ratio. The high elastance group (H group, n = 14) had a ratio ≥30%, and the low elastance group (L group, n = 10) had a ratio <30%. Respiratory elastance, gas-exchange, Paw stress index, and PL stress index were measured. Student's t-test, regression analysis, and Bland–Altman analysis were used for statistical analysis. Results: Pneumonia was the major cause of respiratory failure (71.0%). Compared with the L group, PEEP was lower in the H group (5.7 ± 1.7 cmH2O vs. 9.0 ± 2.3 cmH2O, P < 0.01). Compared with the H group, lung elastance was higher (20.0 ± 7.8 cmH2O/L vs. 11.6 ± 3.6 cmH2O/L, P < 0.01), and stress was higher in the L group (7.0 ± 1.9 vs. 4.9 ± 1.9, P = 0.02). A linear relationship was observed between the Paw stress index and the PL stress index in H group (R2= 0.56, P < 0.01) and L group (R2= 0.85, P < 0.01). Conclusion: In the ARF patients with MV, Paw stress index can substitute for PL to guide ventilator settings. Trial Registration: ClinicalTrials.gov NCT02196870 (https

  11. Impact of Patient Education on Compliance with Positive Airway Pressure Treatment in Obstructive Sleep Apnea.

    PubMed

    Saraç, Sema; Afşar, Gülgün Çetintaş; Oruç, Özlem; Topçuoğlu, Özgür Bilgin; Saltürk, Cüneyt; Peker, Yüksel

    2017-04-13

    BACKGROUND We addressed the impact of patient education followed by frequent visits on compliance with positive airway pressure (PAP) treatment in patients with obstructive sleep apnea (OSA) in a Turkish sleep clinic cohort. MATERIAL AND METHODS This single-center, randomized, controlled study was conducted in Istanbul, Turkey between June 2014 and April 2015. Among 115 eligible OSA patients (mean age 51.0±9.3 years; 75.5% men), 63 were randomized to standard support (SS) group (general information about OSA and PAP treatment at baseline), and 52 to educational support (ES) group (additional polysomnography chart viewing from both diagnostic and titration nights). All patients were scheduled to five PAP control visits between two weeks and six months after the PAP prescription. Primary outcome was the PAP compliance (4 hours/night for 70% of all the nights) at the last visit. RESULTS Average PAP usage was 4.2±2.5 hours/night in the SS group, and 5.2±2.1 hours/night in the ES group (p=0.027). PAP compliance was achieved among 68.3% in the SS group, and 86.5% in the ES group (p=0.021). In a multivariate analysis, ES strategy followed by frequent visits predicted PAP compliance (odds ratio [OR] 3.6, 95% confidence interval [CI] 1.2-10.6; p=0.020). Other predictors were obesity (OR 3.4, 95% CI 1.2-9.7; p=0.019) and severe OSA (apnea-hypopnea index ≥30/hour) at baseline (OR 4.7, 95% CI 1.2-17.6; p=0.023). Primary school education level was inversely related with PAP compliance (OR 0.3, 95% CI 0.1-0.9; p=0.036). CONCLUSIONS Patient education with polysomnography chart view followed by frequent visits increased long-term compliance with PAP treatment.

  12. Nasal Expiratory Positive Airway Pressure Devices (Provent) for OSA: A Systematic Review and Meta-Analysis

    PubMed Central

    Riaz, Muhammad; Certal, Victor; Nigam, Gaurav; Abdullatif, Jose; Zaghi, Soroush; Kushida, Clete A.; Camacho, Macario

    2015-01-01

    Objective. To quantify the effectiveness of nasal expiratory positive airway pressure (nasal EPAP) devices or Provent as treatment for obstructive sleep apnea (OSA). Methods. PubMed and six other databases were searched through November 15, 2015, without language limitations. Results. Eighteen studies (920 patients) were included. Pre- and post-nasal EPAP means ± standard deviations (M ± SD) for apnea-hypopnea index (AHI) in 345 patients decreased from 27.32 ± 22.24 to 12.78 ± 16.89 events/hr (relative reduction = 53.2%). Random effects modeling mean difference (MD) was −14.78 events/hr [95% CI −19.12, −10.45], p value < 0.00001. Oxygen desaturation index (ODI) in 247 patients decreased from 21.2 ± 19.3 to 12.4 ± 14.1 events/hr (relative reduction = 41.5%, p value < 0.00001). Lowest oxygen saturation (LSAT) M ± SD improved in 146 patients from 83.2 ± 6.8% to 86.2 ± 11.1%, MD 3 oxygen saturation points [95% CI 0.57, 5.63]. Epworth Sleepiness Scale (ESS) M ± SD improved (359 patients) from 9.9 ± 5.3 to 7.4 ± 5.0, MD −2.5 [95% CI −3.2, −1.8], p value < 0.0001. Conclusion. Nasal EPAP (Provent) reduced AHI by 53.2%, ODI by 41.5% and improved LSAT by 3 oxygen saturation points. Generally, there were no clear characteristics (demographic factors, medical history, and/or physical exam finding) that predicted favorable response to these devices. However, limited evidence suggests that high nasal resistance could be associated with treatment failure. Additional studies are needed to identify demographic and polysomnographic characteristics that would predict therapeutic success with nasal EPAP (Provent). PMID:26798519

  13. Upper airway dynamics during negative expiratory pressure in apneic and non-apneic awake snorers

    PubMed Central

    Ferretti, A; Giampiccolo, P; Redolfi, S; Mondini, S; Cirignotta, F; Cavalli, A; Tantucci, C

    2006-01-01

    Background The ability of negative expiratory pressure (NEP) technique to differentiate between awake snorers with and without obstructive sleep apnea-hypopnea (OSAH) was investigated. Methods Forty-eight subjects with sleep disordered breathing (SDB) and 7 healthy subjects, as non-snorer controls, underwent the NEP application of -5 and -7 cmH2O in the seated and supine position during wakefulness, after performing a sleep study. The upper airway collapsibility was assessed by computing the volume exhaled during the first 0.5 sec. (V,NEP0.5) and 1 sec. (V,NEP1) following the NEP start. Results Patients with severe (AHI ≥ 30) (n = 19) and mild-to-moderate (AHI <30 and >5) (n = 15) OSAH had lower V,NEP0.5 (340 ± 88 ml) as compared to snorers (AHI ≤ 5) (n = 14) (427 ± 101 ml; p < 0.01) and controls (n = 7) (492 ± 69 ml; p < 0.001) in the supine position with NEP -5 cmH2O. Less significant differences among the different groups were observed for V,NEP0.5 in the seated position with NEP -5 cmH2O and in both positions with NEP -7 cmH2O (only OSAH patients vs controls, p < 0.001). Similar results were obtained for V,NEP1 in either position by using both NEP -5 cmH2O and -7 cmH2O. In spite of this, a substantial overlapping of V,NEP0.5 and V,NEP1 between snorers and OSAH patients did not allow to identify a reliable diagnostic cut-off level. An inverse correlation with AHI was found for V,NEP0.5 in the supine position with NEP -5 cmH2O (rs = -0.46, p < 0.05) in severe OSAH patients. Conclusion The awake OSAH patients exhibit values of V,NEP0.5 and V,NEP1 lesser than those of awake snorers. The NEP technique, however, appears to have a limited usefulness as clinical tool for routine screening of the OSAH patients during wakefulness. PMID:16573817

  14. A pilot study of quantitative assessment of mandible advancement using pressure-flow relationship during midazolam sedation.

    PubMed

    Ayuse, T; Hoshino, Y; Inazawa, T; Oi, K; Schneider, H; Schwartz, A R

    2006-11-01

    It has been proposed that a titration of the mandibular positioner would be a promising method for predicting the outcome of nasal continuous positive airway pressure (CPAP) therapy. This study was carried out to test the hypothesis that mandible advancement could be evaluated by analysis of inspiratory flow limitation using a titration procedure. To explore its effect, we examined upper airway pressure-flow relationships using a titrated mandible positioner during midazolam sedation. Non-flow limited inspiration occurred when the mandible was advanced 7.1 +/- 1.2 mm from centric occlusion position. In the centric occlusion position (0 mm advancement), Pcrit was -1.9 +/- 2.9 cmH2O and Rua was 23.3 +/- 4.5 cmH2O L(-1) s(-1). In the eMAP position, Pcrit was -7.3 +/- 1.9 cmH2O and Rua was 27.8 +/- 3.3 cmH2O L(-1) s(-1). Essentially no CPAP was required to overcome flow limitation in eMAP position, whereas 3.7 +/- 2.2 cmH2O CPAP was required in centric occlusion position. We conclude that assessing inspiratory flow limitation using a titrated mandible positioner was effective for estimating individual-matched mandible positions.

  15. Differences in Perceptions of the Diagnosis and Treatment of Obstructive Sleep Apnea and Continuous Positive Airway Pressure Therapy Among Adherers and Nonadherers

    PubMed Central

    Sawyer, Amy M.; Deatrick, Janet A.; Kuna, Samuel T.; Weaver, Terri E.

    2010-01-01

    Obstructive sleep apnea (OSA) patients’ consistent use of CPAP is critical to realizing improved functional outcomes and reducing untoward health risks associated with OSA. We conducted a mixed methods concurrent, nested study to describe OSA patients’ beliefs and perceptions of the diagnosis and CPAP treatment that importantly differentiate adherent from nonadherent patients prior to and after the first week of treatment when the pattern of CPAP use is established. Guided by social cognitive theory, themes were derived from 30 interviews conducted post-diagnosis and after one week CPAP use. Directed content analysis followed by categorization of participants as adherent/nonadherent from objectively measured CPAP use preceded across-case analysis among 15 participants with severe OSA. Beliefs and perceptions that differed between adherers and nonadherers included OSA risk perception, symptom recognition, self-efficacy, outcome expectations, treatment goals, and treatment facilitators/barriers. Our findings suggest opportunities for developing and testing tailored interventions to promote CPAP use. PMID:20354236

  16. Use of volume-targeted non-invasive bilevel positive airway pressure ventilation in a patient with amyotrophic lateral sclerosis*,**

    PubMed Central

    Diaz-Abad, Montserrat; Brown, John Edward

    2014-01-01

    Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disease in which most patients die of respiratory failure. Although volume-targeted non-invasive bilevel positive airway pressure (BPAP) ventilation has been studied in patients with chronic respiratory failure of various etiologies, its use in ALS has not been reported. We present the case of a 66-year-old woman with ALS and respiratory failure treated with volume-targeted BPAP ventilation for 15 weeks. Weekly data downloads showed that disease progression was associated with increased respiratory muscle weakness, decreased spontaneous breathing, and increased use of non-invasive positive pressure ventilation, whereas tidal volume and minute ventilation remained relatively constant. PMID:25210968

  17. Interaction between otorhinolaryngology and orthodontics: correlation between the nasopharyngeal airway and the craniofacial complex.

    PubMed

    Stellzig-Eisenhauer, Angelika; Meyer-Marcotty, Philipp

    2010-01-01

    In terms of pathophysiology, an anatomically narrow airway is a predisposing factor for obstruction of the upper respiratory tract. The correlation between the nasopharyngeal airway and the craniofacial structures is discussed in this context. Thus a mutual interaction between the pharynx and the mandibular position was demonstrated, whereby the transverse dimension of the nasopharynx was significantly larger in patients with prognathism than in patients with retrognathism. The influence of chronic obstruction of the nasal airway on craniofacial development was also discussed. The form-and-function interaction, which ought to explain the causal relationship between nasal obstruction and craniofacial growth, appears to be of a multifactorial rather than a one-dimensional, linear nature. It is not disputed, however, that expanding the maxilla improves not only nasal volume and nasal flow, but also the subjective sensation of patients, although it is not possible to make a prognostic statement about the extent of this improvement because of the differing reactions of individuals. Orthodontic appliances for advancing the mandible can also be successfully used in the treatment of mild obstructive sleep apnea syndrome. This treatment method should be considered particularly for patients who are unwilling to undergo or cannot tolerate CPAP (continuous positive airway pressure) treatment.

  18. Upper Airway Stimulation for Obstructive Sleep Apnea: Past, Present, and Future

    PubMed Central

    Dedhia, Raj C.; Strollo, Patrick J.; Soose, Ryan J.

    2015-01-01

    Obstructive sleep apnea (OSA) is an increasingly prevalent clinical problem with significant effects on both personal and public health. Continuous positive airway pressure (CPAP) has demonstrated excellent efficacy and low morbidity; long-term adherence rates approach 50%. Although traditional upper airway surgical procedures target the anatomic component of obstruction, upper airway stimulation tackles the twin goals of improving anatomic and neuromuscular pathology. After decades of trials demonstrating proof of concept of hypoglossal nerve stimulation in animal and human subjects, the results of a large multicenter, prospective trial were recently published. The trial demonstrated that hypoglossal nerve stimulation led to significant improvements in objective and subjective measurements of the severity of OSA. This novel approach is the first to combine sleep surgery techniques with a titratable medical device for the treatment of OSA. Further research is required to define optimal patient selection and device performance and to demonstrate long-term effectiveness. Citation: Dedhia RC, Strollo PJ, Soose RJ. Upper airway stimulation for obstructive sleep apnea: past, present, and future. SLEEP 2015;38(6):899– 906. PMID:25409109

  19. Interaction between otorhinolaryngology and orthodontics: correlation between the nasopharyngeal airway and the craniofacial complex

    PubMed Central

    Stellzig-Eisenhauer, Angelika; Meyer-Marcotty, Philipp

    2011-01-01

    In terms of pathophysiology, an anatomically narrow airway is a predisposing factor for obstruction of the upper respiratory tract. The correlation between the nasopharyngeal airway and the craniofacial structures is discussed in this context. Thus a mutual interaction between the pharynx and the mandibular position was demonstrated, whereby the transverse dimension of the nasopharynx was significantly larger in patients with prognathism than in patients with retrognathism. The influence of chronic obstruction of the nasal airway on craniofacial development was also discussed. The form-and-function interaction, which ought to explain the causal relationship between nasal obstruction and craniofacial growth, appears to be of a multifactorial rather than a one-dimensional, linear nature. It is not disputed, however, that expanding the maxilla improves not only nasal volume and nasal flow, but also the subjective sensation of patients, although it is not possible to make a prognostic statement about the extent of this improvement because of the differing reactions of individuals. Orthodontic appliances for advancing the mandible can also be successfully used in the treatment of mild obstructive sleep apnea syndrome. This treatment method should be considered particularly for patients who are unwilling to undergo or cannot tolerate CPAP (continuous positive airway pressure) treatment. PMID:22073108

  20. Dynamic Characteristics of Mechanical Ventilation System of Double Lungs with Bi-Level Positive Airway Pressure Model

    PubMed Central

    Shen, Dongkai; Zhang, Qian

    2016-01-01

    In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP) controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics. PMID:27660646

  1. Airway pressure release ventilation in morbidly obese surgical patients with acute lung injury and acute respiratory distress syndrome.

    PubMed

    Testerman, George M; Breitman, Igal; Hensley, Sarah

    2013-03-01

    Morbidly obese patients with body mass index greater than 40 kg/m(2) and respiratory failure requiring critical care services are increasingly seen in trauma and acute care surgical centers. Baseline respiratory pathophysiology including decreased pulmonary compliance with dependent atelectasis and abnormal ventilation-perfusion relationships predisposes these patients to acute lung injury (ALI) and adult respiratory distress syndrome (ARDS) as well as prolonged stays in the intensive care unit. Airway pressure release ventilation (APRV) is an increasingly used alternative mode for salvage therapy in patients with hypoxemic respiratory failure that also provides lung protection from ventilator-induced lung injury. APRV provides the conceptual advantage of an "open lung" approach to ventilation that may be extended to the morbidly obese patient population with ALI and ARDS. We discuss the theoretical benefits and a recent clinical experience of APRV ventilation in the morbidly obese patient with respiratory failure at a Level I trauma, surgical critical care, and acute care surgery center.

  2. A Respiratory Airway-Inspired Low-Pressure, Self-Regulating Valve for Drip Irrigation

    NASA Astrophysics Data System (ADS)

    Wang, Ruo-Qian; Winter, Amos G.; GEAR Lab Team

    2015-11-01

    One of the most significant barriers to achieving large-scale dissemination of drip irrigation is the cost of the pump and power system. An effective means of reducing power consumption is by reducing pumping pressure. The principle source of pressure drop in a drip system is the high flow resistance in the self-regulating flow resistors installed at the outlets of the pips, which evenly distribute water over a field. Traditional architectures require a minimum pressure of ~1 bar to maintain a constant flow rate; our aim is to reduce this pressure by 90% and correspondingly lower pumping power to facilitate the creation of low-cost, off-grid drip irrigation systems. This study presents a new Starling resistor architecture that enables the adjustment of flow rate with a fixed minimum pressure demand of ~0.1 bar. A Starling resistor is a flexible tube subjected to a transmural pressure, which collapses the tube to restrict flow. Our design uses a single pressure source to drive flow through the flexible tube and apply a transmural pressure. Flow into the flexible tube is restricted with a needle valve, to increase the transmural pressure. Using this device, a series of experiments were conducted with different flexible tube diameters, lengths and wall thickness. We found that the resistance of the needle valve changes flow rate but not the minimum transmural pressure required to collapse the tube. A lumped-parameter model was developed to capture the relationships between valve openings, pressure, and flow rates.

  3. CPAP, effective respiratory support in patients with AIDS-related Pneumocystis carinii pneumonia.

    PubMed

    Prevedoros, H P; Lee, R P; Marriot, D

    1991-11-01

    Human Immunodeficiency Virus (HIV) related Pneumocystis carinii pneumonia (PCP) associated with severe respiratory failure is an increasingly common problem in major centres and is associated with a high mortality in previous and recent studies. Early in the epidemic, alternatives to invasive intensive care treatment were utilized in our institution and found to be successful. When respiratory failure developed, mask CPAP was used instead of intubation and ventilation. A retrospective review of 175 cases of HIV infected patients with confirmed first presentation PCP was undertaken. Treatment with our protocol resulted in an overall hospital mortality of 9%. Those patients who did not require supplemental oxygen or respiratory support had no in-hospital mortality. The group who required supplemental oxygen had a mortality of 10%. If respiratory failure supervened (severe respiratory distress, PaO2 less than 50 mmHg, SaO2 less than 90% on mask oxygen), CPAP was introduced. The mortality in this group was 22%. Only two patients were admitted to the intensive care unit for respiratory support after failure of CPAP. Both patients were intubated and received intermittent positive pressure ventilation (IPPV). Both patients died.

  4. The effect of obstructive sleep apnea and treatment with continuous positive airway pressure on stroke rehabilitation: rationale, design and methods of the TOROS study

    PubMed Central

    2014-01-01

    Background Obstructive sleep apnea is a common sleep disorder in stroke patients. Obstructive sleep apnea is associated with stroke severity and poor functional outcome. Continuous positive airway pressure seems to improve functional recovery in stroke rehabilitation. To date, the effect of continuous positive airway pressure on cognitive functioning in stroke patients is not well established. The current study will investigate the effectiveness of continuous positive airway pressure on both cognitive and functional outcomes in stroke patients with obstructive sleep apnea. Methods/Design A randomized controlled trial will be conducted on the neurorehabilitation unit of Heliomare, a rehabilitation center in the Netherlands. Seventy stroke patients with obstructive sleep apnea will be randomly allocated to an intervention or control group (n = 2×35). The intervention will consist of four weeks of continuous positive airway pressure treatment. Patients allocated to the control group will receive four weeks of treatment as usual. Outcomes will be assessed at baseline, immediately after the intervention and at two-month follow-up. In a supplementary study, these 70 patients with obstructive sleep apnea will be compared to 70 stroke patients without obstructive sleep apnea with respect to cognitive and functional status at rehabilitation admission. Additionally, the societal participation of both groups will be assessed at six months and one year after inclusion. Discussion This study will provide novel information on the effects of obstructive sleep apnea and its treatment with continuous positive airway pressure on rehabilitation outcomes after stroke. Trial registration Trial registration number: Dutch Trial Register NTR3412 PMID:24568360

  5. Health effects of obstructive sleep apnoea and the effectiveness of continuous positive airways pressure: a systematic review of the research evidence.

    PubMed Central

    Wright, J.; Johns, R.; Watt, I.; Melville, A.; Sheldon, T.

    1997-01-01

    OBJECTIVE: To examine the research evidence for the health consequences of obstructive sleep apnoea and the effectiveness of continuous positive airways pressure. DESIGN: A systematic review of published research, studies being identified by searching Medline (1966-96), Embase (1974-96), and CINAHL (Cumulative Index to Nursing and Allied Health Literature) (1982-95); scanning citations; and consulting experts. Studies in all languages were considered which either investigated the association between obstructive sleep apnoea in adults and key health outcomes or evaluated the effectiveness of treatment of obstructive sleep apnoea with continuous positive airways pressure in adults. MAIN OUTCOME MEASURES: Mortality, systematic hypertension, cardiac arrhythmias, ischaemic heart disease, left ventricular hypertrophy, pulmonary hypertension, stroke, vehicle accidents, measures of daytime sleepiness, and quality of life. RESULTS: 54 epidemiological studies examined the association between sleep apnoea and health related outcomes. Most were poorly designed and only weak or contradictory evidence was found of an association with cardiac arrhythmias, ischaemic heart disease, cardiac failure, systemic or pulmonary hypertension, and stroke. Evidence of a link with sleepiness and road traffic accidents was stronger but inconclusive. Only one small randomised controlled trial evaluated continuous positive airways pressure. Five non-randomised controlled trials and 38 uncontrolled trials were identified. Small changes in objectively measured daytime sleepiness were consistently found, but improvements in morbidity, mortality, and quality of life indicators were not adequately assessed. CONCLUSIONS: The relevance of sleep apnoea to public health has been exaggerated. The effectiveness of continuous positive airways pressure in improving health outcomes has been poorly evaluated. There is enough evidence suggesting benefit in reducing daytime sleepiness in some patients to warrant

  6. End-inspiratory airway occlusion: a method to assess the pressure developed by inspiratory muscles in patients with acute lung injury undergoing pressure support.

    PubMed

    Foti, G; Cereda, M; Banfi, G; Pelosi, P; Fumagalli, R; Pesenti, A

    1997-10-01

    We evaluated the end-inspiratory occlusion maneuver as a means to estimate the inspiratory effort during pressure support ventilation (PS). In nine nonobstructed acute lung injury (ALI) patients, we applied four levels of PS (0, 5, 10, 15 cm H2O) to modify the inspiratory effort. End inspiratory occlusions (2 to 3 s) were performed at the end of each experimental period by pushing the inspiratory hold button of the ventilator (Servo 900 C; Siemens, Berlin, Germany). We took the difference between the end-inspiratory occlusion plateau pressure and the airway pressure before the occlusion (PEEP + PS) as an estimate of the inspiratory effort and called it PMI (Pmusc,index). From the esophageal pressure tracing we obtained a reference measurement of the pressure developed by the inspiratory muscles at end inspiration (Pmusc,ei) and of the pressure-time product per breath (PTP/b) and per minute (PTP/min). In each patient, PMI was correlated with Pmusc,ei (p < 0.01) and PTP/b (p < 0.01). A PMI threshold of 6 cm H2O detected PTP/min < 125 cm H2O s/min with a sensitivity of 0.89 and a specificity of 0.89. We conclude that PMI is a good estimate of the pressure developed by the inspiratory muscles in ALI patients and may be used to titrate PS level. The major advantage of PMI is that it can be obtained from the ventilator display without any additional equipment.

  7. Midfacial and Dental Changes Associated with Nasal Positive Airway Pressure in Children with Obstructive Sleep Apnea and Craniofacial Conditions

    PubMed Central

    Roberts, Soleil D.; Kapadia, Hitesh; Greenlee, Geoff; Chen, Maida L.

    2016-01-01

    Study Objectives: Nasal positive airway pressure (nPAP) for treatment of pediatric obstructive sleep apnea (OSA) is a widespread therapy that currently lacks longitudinal data describing how mask pressure impacts the developing facial skeleton. This retrospective cohort study compared midfacial growth in pediatric patients with underlying craniofacial conditions diagnosed with OSA who were compliant vs. noncompliant with nPAP therapy, and explored correlations between demographic, medical, and sleep variables with annual rate of facial change. Methods: Records from Seattle Children's Hospital's Craniofacial Center and Sleep Disorders Center were reviewed to identify patients prescribed nPAP for OSA with serial cephalographic images obtained during routine clinical care for concomitant craniofacial diagnosis. Lateral cephalometric analysis was used to determine mean annual change in midfacial structures from T1 (pre-nPAP) to T2 (post-nPAP) in compliant vs. noncompliant subjects. Compliance was indicated by nPAP usage of > 20 h/week for > 6 months. Results: 50 subjects were compliant with nPAP therapy (mean age 10.42 years) for an average of 2.57 years, and 50 subjects were noncompliant (mean age 8.53 years). Compliant subjects experienced negative mean annual change (retrusion) of the midface compared to forward growth seen in noncompliant subjects (SNA: −0.57° vs. 0.56°), counterclockwise rotation of palatal plane (SN-PP: −1.15° vs. 0.09°), and upper incisor flaring (U1-SN: 2.41° vs. −0.51°). Conclusions: Pressure to the midface from compliant nPAP use may alter normal facial growth. Cephalometric findings indicate a greater need for collaboration between sleep medicine physicians and orthodontists to monitor midfacial growth during nPAP treatment. Citation: Roberts SD, Kapadia H, Greenlee G, Chen ML. Midfacial and dental changes associated with nasal positive airway pressure in children with obstructive sleep apnea and craniofacial conditions. J Clin

  8. Centriolar CPAP/SAS-4 Imparts Slow Processive Microtubule Growth.

    PubMed

    Sharma, Ashwani; Aher, Amol; Dynes, Nicola J; Frey, Daniel; Katrukha, Eugene A; Jaussi, Rolf; Grigoriev, Ilya; Croisier, Marie; Kammerer, Richard A; Akhmanova, Anna; Gönczy, Pierre; Steinmetz, Michel O

    2016-05-23

    Centrioles are fundamental and evolutionarily conserved microtubule-based organelles whose assembly is characterized by microtubule growth rates that are orders of magnitude slower than those of cytoplasmic microtubules. Several centriolar proteins can interact with tubulin or microtubules, but how they ensure the exceptionally slow growth of centriolar microtubules has remained mysterious. Here, we bring together crystallographic, biophysical, and reconstitution assays to demonstrate that the human centriolar protein CPAP (SAS-4 in worms and flies) binds and "caps" microtubule plus ends by associating with a site of β-tubulin engaged in longitudinal tubulin-tubulin interactions. Strikingly, we uncover that CPAP activity dampens microtubule growth and stabilizes microtubules by inhibiting catastrophes and promoting rescues. We further establish that the capping function of CPAP is important to limit growth of centriolar microtubules in cells. Our results suggest that CPAP acts as a molecular lid that ensures slow assembly of centriolar microtubules and, thereby, contributes to organelle length control.

  9. The effects of positive expiratory pressure on isovolume flow and dynamic hyperinflation in patients receiving mechanical ventilation.

    PubMed

    Gay, P C; Rodarte, J R; Hubmayr, R D

    1989-03-01

    The use of continuous positive airway pressure (CPAP) or positive end-expiratory pressure (PEEP) has been advocated by some to assist in the weaning process of patients receiving mechanical ventilation for respiratory failure. The efficacy of this technique and its effect on respiratory system mechanics are not well understood. The theoretical advantage of CPAP or PEEP during the weaning process can be obliterated if excessive dynamic hyperinflation is induced. A key determinant of the individual response to this proposed weaning technique is the recognition of the presence or absence of expiratory flow limitation. We studied the effect of progressively increased levels of applied PEEP on isovolume expiratory flow and end-expiratory lung volume in seven patients during controlled mechanical ventilation. In the absence of expiratory flow limitation, passive expiratory flow decreased and end-expiratory lung volume increased when any level of PEEP was applied. In contrast, flow-limited patients did not demonstrate a change in isovolume expiratory flow or end-expiratory lung volume until the applied PEEP reduced the driving pressure for expiratory flow below a critical value. All patients demonstrated dynamic hyperinflation during controlled ventilation as evident by the existence of intrinsic PEEP. The nominal value of applied PEEP that caused a reduction in isovolume expiratory flow was unrelated to the initial level of intrinsic PEEP. The clinical implications of these findings with respect to CPAP therapy during weaning from mechanical ventilation are discussed.

  10. Residual Events during Use of CPAP: Prevalence, Predictors, and Detection Accuracy

    PubMed Central

    Reiter, Joel; Zleik, Bashar; Bazalakova, Mihaela; Mehta, Pankaj; Thomas, Robert Joseph

    2016-01-01

    Study Objectives: To assess the frequency, severity, and determinants of residual respiratory events during continuous positive airway therapy (CPAP) for obstructive sleep apnea (OSA) as determined by device output. Methods: Subjects were consecutive OSA patients at an American Academy of Sleep Medicine accredited multidisciplinary sleep center. Inclusion criteria included CPAP use for a minimum of 3 months, and a minimum nightly use of 4 hours. Compliance metrics and waveform data from 217 subjects were analyzed retrospectively. Events were scored manually when there was a clear reduction of amplitude (≥ 30%) or flow-limitation with 2–3 larger recovery breaths. Automatically detected versus manually scored events were subjected to statistical analyses included Bland-Altman plots, correlation coefficients, and logistic regression exploring predictors of residual events. Results: The mean patient age was 54.7 ± 14.2 years; 63% were males. All patients had a primary diagnosis of obstructive sleep apnea, 26% defined as complex sleep apnea. Residual flow measurement based apnea-hypopnea index (AHIFLOW) > 5, 10, and 15/h was seen in 32.3%, 9.7%, and 1.8% vs. 60.8%, 23%, and 7.8% of subjects based on automated vs. manual scoring of waveform data. Automatically detected versus manually scored average AHIFLOW was 4.4 ± 3.8 vs. 7.3 ± 5.1 per hour. In a logistic regression analysis, the only predictors for a manual AHIFLOW > 5/h were the absolute central apnea index (CAI), (odds ratio [OR]: 1.5, p: 0.01, CI: 1.1–2.0), or using a CAI threshold of 5/h of sleep (OR: 5.0, p: < 0.001, CI: 2.2–13.8). For AHIFLOW > 10/h, the OR was 1.14, p: 0.03 (CI: 1.1–1.3) per every CAI unit of 1/hour. Conclusions: Residual respiratory events are common during CPAP treatment, may be missed by automated device detection and predicted by a high central apnea index on the baseline diagnostic study. Direct visualization of flow data is generally available and improves detection

  11. Phosphorylation of CPAP by Aurora-A Maintains Spindle Pole Integrity during Mitosis.

    PubMed

    Chou, En-Ju; Hung, Liang-Yi; Tang, Chieh-Ju C; Hsu, Wen-Bin; Wu, Hsin-Yi; Liao, Pao-Chi; Tang, Tang K

    2016-03-29

    CPAP is required for centriole elongation during S/G2 phase, but the role of CPAP in mitosis is incompletely understood. Here, we show that CPAP maintains spindle pole integrity through its phosphorylation by Aurora-A during mitosis. Depletion of CPAP induced a prolonged delay in mitosis, pericentriolar material (PCM) dispersion, and multiple mitotic abnormalities. Further studies demonstrated that CPAP directly interacts with and is phosphorylated by Aurora-A at serine 467 during mitosis. Interestingly, the dispersal of the PCM was effectively rescued by ectopic expression of wild-type CPAP or a phospho-mimic CPAP-S467D mutant, but not a non-phosphorylated CPAP-S467A mutant. Finally, we found that CPAP-S467D has a low affinity for microtubule binding but a high affinity for PCM proteins. Together, our results support a model wherein CPAP is required for proper mitotic progression, and phosphorylation of CPAP by Aurora-A is essential for maintaining spindle pole integrity.

  12. A real-world comparison of apnea-hypopnea indices of positive airway pressure device and polysomnography.

    PubMed

    Agrawal, Ritwick; Wang, Julie A; Ko, Anita G; Getsy, Joanne E

    2017-01-01

    The apnea hypopnea index (AHI) reported by positive airway pressure (PAP) device is widely used in clinical practice, yet its correlation with standardized AHI obtained during the sleep study is not established. The current study was conducted to investigate the correlation between AHI estimated by the PAP device and reported on the smart card with the AHI found during the PAP polysomnography (PSG) in the "real world" setting at an academic sleep center. We retrospectively reviewed the medical records of 280 patients who underwent a PAP titration PSG at Drexel sleep center, and were later prescribed a PAP device. The AHI was categorized in clinically relevant subgroups (as AHI ≤5 and AHI >5). The AHI at the final pressure on the PSG and the average AHI from the prescribed PAP device were compared. The results showed that in the majority (77.3%) of patients (126 of 163), the AHI from both PAP device and PSG correlated well and were in the same category (AHI ≤5 and AHI >5 respectively). The majority of patients (80.7%) with PSG AHI of <5 had PAP device AHI <5 as well. By contrast, if PSG AHI was >5, 61.5% patients reported good control, with AHI <5 on PAP device AHI. We conclude that in a majority of patients who were optimally titrated in the sleep laboratory, the PAP device continued to show optimal control at home.

  13. Thoracic Block Technique Associated with Positive End-Expiratory Pressure in Reversing Atelectasis

    PubMed Central

    Pereira, Luciana Carnevalli; de Souza Netto, Ana Paula; da Silva, Fernanda Cordeiro; Pereira, Silvana Alves; Moran, Cristiane Aparecida

    2015-01-01

    A preschool four-year-old male patient had been admitted to the Mandaqui Hospital with a diagnosis of lobar pneumonia, pleural effusion, and right lung atelectasis. Treatment consisted of antibiotics and physiotherapy sessions, using a technique described in the literature as Insufflation Technique to Reverse Atelectasis (ITRA), which consists of a thoracic block of healthy lung tissue, leaving only the atelectasis area free, associated with the use of invasive or noninvasive mechanical ventilation with positive airway pressure for reversal of atelectasis. Two physiotherapy sessions were conducted daily. The sessions lasted 20 minutes and were fractionated into four series of five minutes each. Each series bilateral thoracic block was performed for 20 seconds with a pause lasting for the same time. Associated with the thoracic block, a continuous positive airways pressure was used using a facial mask and 7 cm H2O PEEP provided via CPAP. Conclusion. ITRA technique was effective in reversing atelectasis in this patient. PMID:25883824

  14. Cystic fibrosis airway secretions exhibit mucin hyperconcentration and increased osmotic pressure.

    PubMed

    Henderson, Ashley G; Ehre, Camille; Button, Brian; Abdullah, Lubna H; Cai, Li-Heng; Leigh, Margaret W; DeMaria, Genevieve C; Matsui, Hiro; Donaldson, Scott H; Davis, C William; Sheehan, John K; Boucher, Richard C; Kesimer, Mehmet

    2014-07-01

    The pathogenesis of mucoinfective lung disease in cystic fibrosis (CF) patients likely involves poor mucus clearance. A recent model of mucus clearance predicts that mucus flow depends on the relative mucin concentration of the mucus layer compared with that of the periciliary layer; however, mucin concentrations have been difficult to measure in CF secretions. Here, we have shown that the concentration of mucin in CF sputum is low when measured by immunologically based techniques, and mass spectrometric analyses of CF mucins revealed mucin cleavage at antibody recognition sites. Using physical size exclusion chromatography/differential refractometry (SEC/dRI) techniques, we determined that mucin concentrations in CF secretions were higher than those in normal secretions. Measurements of partial osmotic pressures revealed that the partial osmotic pressure of CF sputum and the retained mucus in excised CF lungs were substantially greater than the partial osmotic pressure of normal secretions. Our data reveal that mucin concentration cannot be accurately measured immunologically in proteolytically active CF secretions; mucins are hyperconcentrated in CF secretions; and CF secretion osmotic pressures predict mucus layer-dependent osmotic compression of the periciliary liquid layer in CF lungs. Consequently, mucin hypersecretion likely produces mucus stasis, which contributes to key infectious and inflammatory components of CF lung disease.

  15. Application of positive airway pressure in restoring pulmonary function and thoracic mobility in the postoperative period of bariatric surgery: a randomized clinical trial

    PubMed Central

    Brigatto, Patrícia; Carbinatto, Jéssica C.; Costa, Carolina M.; Montebelo, Maria I. L.; Rasera-Júnior, Irineu; Pazzianotto-Forti, Eli M.

    2014-01-01

    Objective: To evaluate whether the application of bilevel positive airway pressure in the postoperative period of bariatric surgery might be more effective in restoring lung volume and capacity and thoracic mobility than the separate application of expiratory and inspiratory positive pressure. Method: Sixty morbidly obese adult subjects who were hospitalized for bariatric surgery and met the predefined inclusion criteria were evaluated. The pulmonary function and thoracic mobility were preoperatively assessed by spirometry and cirtometry and reevaluated on the 1st postoperative day. After preoperative evaluation, the subjects were randomized and allocated into groups: EPAP Group (n=20), IPPB Group (n=20) and BIPAP Group (n=20), then received the corresponding intervention: positive expiratory pressure (EPAP), inspiratory positive pressure breathing (IPPB) or bilevel inspiratory positive airway pressure (BIPAP), in 6 sets of 15 breaths or 30 minutes twice a day in the immediate postoperative period and on the 1st postoperative day, in addition to conventional physical therapy. Results: There was a significant postoperative reduction in spirometric variables (p<0.05), regardless of the technique used, with no significant difference among the techniques (p>0.05). Thoracic mobility was preserved only in group BIPAP (p>0.05), but no significant difference was found in the comparison among groups (p>0.05). Conclusion: The application of positive pressure does not seem to be effective in restoring lung function after bariatric surgery, but the use of bilevel positive pressure can preserve thoracic mobility, although this technique was not superior to the other techniques. PMID:25590448

  16. Oxidative stress and quality of life in elderly patients with obstructive sleep apnea syndrome: are there differences after six months of Continuous Positive Airway Pressure treatment?

    PubMed Central

    Yagihara, Fabiana; Lucchesi, Ligia Mendonça; D'Almeida, Vânia; de Mello, Marco Túlio; Tufik, Sergio; Bittencourt, Lia Rita Azeredo

    2012-01-01

    OBJECTIVES: This study evaluated the effect of Continuous Positive Airway Pressure treatment on oxidative stress parameters and the quality of life of elderly patients with obstructive sleep apnea syndrome. METHODS: In total, 30 obstructive sleep apnea syndrome patients and 27 subjects without obstructive sleep apnea syndrome were included in this study. Both groups underwent quality of life and oxidative stress evaluations at baseline and after six months. Polysomnography was performed in both groups at baseline and a second time in the obstructive sleep apnea syndrome group after six months of Continuous Positive Airway Pressure treatment. All of the variables were compared between the control and obstructive sleep apnea syndrome groups in this prospective case-control study. RESULTS: The baseline concentrations of the antioxidant enzyme catalase were higher in the obstructive sleep apnea syndrome group than the control group. After Continuous Positive Airway Pressure treatment, the obstructive sleep apnea syndrome group exhibited a reduction in the level of oxidative stress, as indicated by a decrease in the level of lipid peroxidation measured by the malondialdehyde (MDA) concentration [pre: 2.7 nmol malondialdehyde/mL (95% 1.6-3.7) vs. post: 1.3 nmol MDA/mL (0.7-1.9), p<0.01]. Additionally, improvements were observed in two domains covered by the SF-36 questionnaire: functional capacity [pre: 77.4 (69.2-85.5) vs. post: 83.4 (76.9-89.9), p = 0.002] and pain [pre: 65.4 (52.8-78.1) vs. post: 77.8 (67.2-88.3), p = 0.004]. CONCLUSION: Our study demonstrated that the use of Continuous Positive Airway Pressure to treat obstructive sleep apnea syndrome in elderly patients reduced oxidative stress and improved the quality of life. PMID:22760893

  17. Airway Pressure Release Ventilation and High-Frequency Oscillatory Ventilation: Potential Strategies to Treat Severe Hypoxemia and Prevent Ventilator-Induced Lung Injury.

    PubMed

    Facchin, Francesca; Fan, Eddy

    2015-10-01

    Although lifesaving, mechanical ventilation can itself be responsible for damage to lung parenchyma. This ventilator-induced lung injury is especially observed in already injured lungs of patients with ARDS. New ventilatory approaches are needed to safely treat patients with ARDS, and recent studies have suggested the potential utility of open-lung strategies. Airway pressure release ventilation (APRV) and high-frequency oscillatory ventilation (HFOV) are 2 different open-lung strategies that have been proposed to treat refractory hypoxemic respiratory failure while preventing ventilator-induced lung injury. APRV provides increased airway pressure as a potential recruitment mechanism and allows spontaneous breathing, with the potential benefits of decreased sedation, shorter duration of mechanical ventilation, and improvement in cardiac performance. HFOV delivers very small tidal volumes, to prevent volutrauma, at a constant (relatively high) mean airway pressure, thus avoiding atelectrauma. Despite their theoretical benefits, the utility of APRV and HFOV remains unproven and controversial for the routine treatment of ARDS in adult patients. This review is focused on the theoretical and practical aspects of APRV and HFOV, provides an overview of the current evidence, and addresses their possible use in the treatment of ARDS.

  18. WHICH AIRWAY PRESSURE SHOULD BE APPLIED DURING BREATH-HOLD IN DOGS UNDERGOING THORACIC COMPUTED TOMOGRAPHY?

    PubMed

    Guarracino, Alessandro; Lacitignola, Luca; Auriemma, Edoardo; De Monte, Valentina; Grasso, Salvatore; Crovace, Antonio; Staffieri, Francesco

    2016-09-01

    This randomized controlled trial study aimed to identify the optimal positive pressure (PP) level that can clear atelectasis while avoiding pulmonary hyperinflation during the breath-hold technique in dogs undergoing thoracic computed tomography (CT). Sixty dogs affected by mammary tumors undergoing thoracic CT for the screening of pulmonary metastases were randomly assigned to six groups with different levels of PP during the breath-hold technique: 0 (control), 5 (PP5), 8 (PP8), 10 (PP10), 12 (PP12), and 15 (PP15) cmH2 O. The percentage of atelectatic lung region was lower in the PP10 (3.7 ± 1.1%; P = 0.002), PP12 (3.4 ± 1.3%; P = 0.0001), and PP15 (2.8 ± 0.9%; P = 0.006) groups than in the control group (5.0 ± 2.3%), and the percentage of poorly aerated lung region was lower in the PP8 (15.1 ± 2.6%; P = 0.0009), PP10 (13.0 ± 2.0 %; P = 0.002), PP12 (13.0 ± 2.2 %; P = 0.0002), and PP15 (11.1 ± 1.9%; P = 0.0002) groups than in the control group (19.8 ± 5.0). The percentage of normally aerated lung region, however, was higher in the PP10 (79.7 ± 4.1%; P = 0.005), PP12 (79.8 ± 5.1%; P = 0.0002), and PP15 (80.2 ± 4.9%; P = 0.002) groups than in the control group (73.4 ± 6.6%). A PP of 10-12 cmH2 O during the breath-hold technique should be considered to improve lung aeration during a breath-hold technique in dogs undergoing thoracic CT.

  19. Influence of body position on the displacement of nasal prongs in preterm newborns receiving continuous positive airway pressure

    PubMed Central

    Brunherotti, Marisa Afonso Andrade; Martinez, Francisco Eulógio

    2015-01-01

    Abstract Objective: To evaluate the influence of body position on the displacement of nasal prongs in preterm infants. Methods: This prospective, randomized, crossover study enrolled infants born at a mean gestational age of 29.7±2 weeks, birth weight of 1353±280g and 2.9±2.2 days of life, submitted to continuous positive airway pressure by nasal prongs. The main outcome was the number of times that the nasal prongs were displaced following infant positioning in the following body positions: prone, right lateral, left lateral, and supine, according to a pre-established random order. Moreover, cardiorespiratory variables (respiratory rate, heart rate, and oxygen saturation) were evaluated for each body position. Data for each position were collected every 10 min, over a period of 60 min. An occurrence was defined when the nasal prongs were displaced from the nostrils after 3 min in the desired position, requiring intervention of the examiner. Results: Among the 16 studied infants, the occurrence of nasal prong displacement was only observed in the prone position (9 infants - 56.2%) and in the left lateral position (2 infants - 12.5%). The number of times that the prongs were displaced was 11 in the prone position (7 within the first 10min) and 2 in the left lateral position (1 within the first 10min). No clinically significant changes were observed in the cardiorespiratory variables. Conclusions: Maintenance of the nasal prongs to provide adequate noninvasive respiratory support was harder in the prone position. PMID:26116326

  20. Elective nasal continuous positive airway pressure to support respiration after prolonged ventilation in infants after congenital cardiac surgery

    PubMed Central

    Gandhi, Hemang; Mishra, Amit; Thosani, Rajesh; Acharya, Himanshu; Shah, Ritesh; Surti, Jigar; Sarvaia, Alpesh

    2017-01-01

    Background: We sought to compare the effectiveness of oxygen (O2) treatment administered by an O2 mask and nasal continuous positive airway pressure (NCPAP) in infants after congenital cardiac surgery. Methods: In this retrospective observational study, 54 infants undergoing corrective cardiac surgery were enrolled. According to the anesthesiologist's preference, the patients ventilated for more than 48 h were either put on NCPAP or O2 mask immediately after extubation. From pre-extubation to 24 h after treatment, arterial blood gas and hemodynamic data were measured. Results: After 24 h of NCPAP institution, the patients showed a significant improvement in oxygenation compared to O2 mask group. Respiratory rate (per minute) decreased from 31.67 ± 4.55 to 24.31 ± 3.69 (P < 0.0001), PO2 (mmHg) increased from 112.12 ± 22.83 to 185.74 ± 14.81 (P < 0.0001), and PCO2 (mmHg) decreased from 42.88 ± 5.01 to 37.00 ± 7.22 (P < 0.0076) in patients on NCPAP. In this group, mean pediatric cardiac surgical Intensive Care Unit (PCSICU) stay was 4.72 ± 1.60 days, with only 2 (11.11%) patients requiring re-intubation. Conclusion: NCPAP can be used safely and effectively in infants undergoing congenital cardiac surgery to improve oxygenation/ventilation. It also reduces the work of breathing, PCSICU stay, and may reduce the likelihood of re-intubation. PMID:28163425

  1. A longitudinal study of CPAP therapy for patients with chronic cough and obstructive sleep apnoea

    PubMed Central

    2013-01-01

    Background Chronic cough patients are rendered therapies for gastro-esophageal reflux (GERD), upper airway cough syndrome (UACS) and cough-variant asthma (CVA) with varying benefit. Idiopathic or unexplained cough has emerged as an important clinical entity in both primary care and subspecialty clinics. Recent evidence points to a link between chronic cough and untreated obstructive sleep apnea (OSA). Methods A prospective observational study was done to evaluate the effect of OSA therapy in patients with chronic cough. Patients enrolled into the study underwent questionnaires to evaluate for GERD, UACS and CVA along with screening questionnaires for OSA and daytime sleepiness. The Leicester cough questionnaire (LCQ) was done at baseline and during serial visits to evaluate cough intensity and was used as the primary outcome measure of the effect of CPAP therapy on chronic cough. Results Out of 37 patients enrolled into the study, only 28 patients had follow up LCQ scores available and therefore underwent analysis. 22/28 patients were suspected to have OSA based on abnormal STOP-BANG screening questionnaire scores and overnight oximetry abnormalities. Of these 19/28 patients had overnight attended polysomnography with definitive diagnosis of OSA yielding a 68% prevalence of OSA in our chronic cough population. Chronic cough patients treated for OSA tended to be older with a significantly higher BMI than chronic cough patients without OSA. Significant improvement of LCQ scores occurred with CPAP therapy for OSA in chronic cough patients. Conclusion OSA is significantly prevalent in chronic cough patients. Subjects with chronic cough and OSA tend to be older and obese. Treatment of OSA in chronic cough patients yields significant improvement in their health status. PMID:23845135

  2. Sleep-related sweating in obstructive sleep apnoea: association with sleep stages and blood pressure.

    PubMed

    Arnardottir, Erna Sif; Thorleifsdottir, Bjorg; Svanborg, Eva; Olafsson, Isleifur; Gislason, Thorarinn

    2010-03-01

    The aim of this study was to investigate sleep-related sweating as a symptom of obstructive sleep apnoea (OSA). Fifteen otherwise healthy male non-smoking patients with untreated moderate-to-severe OSA underwent polysomnography, including measurements of skin and core body temperature and electrodermal activity (EDA) as an objective indicator of sweating. Evening and morning blood pressure was measured as well as catecholamines in nocturnal urine. All measurements were repeated after 3 months on successful continuous positive airway pressure (CPAP) treatment. The untreated OSA subjects had a mean (+/-SD) apnoea-hypopnoea index of 45.3 +/- 3.9 and a mean EDA index during sleep of 131.9 +/- 22.4 events per hour. Patients with higher EDA indices had higher systolic blood pressure in the evening and morning (P = 0.001 and 0.006) and lower rapid eye movement (REM) sleep percentage (P = 0.003). The EDA index decreased significantly to 78.5 +/- 17.7 in the patients on CPAP treatment (P = 0.04). The decrease correlated with lower evening systolic and diastolic blood pressure (P = 0.05 and 0.006) and an increase in REM% (P = 0.02). No relationship was observed between EDA and skin or core body temperature, or to catecholamine levels in urine. OSA patients who experience sleep-related sweating may have increased blood pressure and decreased REM sleep compared with other OSA patients. CPAP treatment appears to lower blood pressure and increase REM sleep to a higher extent in these patients compared with other OSA patients.

  3. The effect of a bellows leak in an Ohmeda 7810 ventilator on room contamination, inspired oxygen, airway pressure, and tidal volume.

    PubMed

    Lampotang, Samsun; Sanchez, Justin C; Chen, Baixi; Gravenstein, Nikolaus

    2005-07-01

    We investigated the effect of a small bellows leak (bellows full at end-expiration) on inspired oxygen fraction (Fio(2)), exhaled tidal volume (Vt), airway pressure, and room contamination in an oxygen-driven anesthesia ventilator (Ohmeda 7810, Madison, WI). CO(2) concentration at the ventilator exhalation valve, Fio(2), Vt, and airway pressure were measured (n = 3) while ventilating a CO(2)-producing test lung at 8 breaths/min and an inspiratory/expiratory ratio of 1:2, with and without a bellows leak (4-mm-long tear). Set Vt was 400, 600, 800, and 1000 mL. Fresh gas flow (FGF) was 0.3 L/min O(2) and (a) 5.0 L/min air, (b) 2.0 L/min air, and (c) 0.2 L/min nitrogen. There was no clinical difference in Fio(2), Vt, PIP (peak inspiratory pressure) and PEEP (positive end-expiratory pressure), with and without a 4-mm bellows tear, at all FGFs and Vt settings. CO(2) at the ventilator exhalation valve was always nonzero with a bellows leak, indicating that CO(2)-laden circuit gas was contaminating the drive gas via the bellows leak. A 4-mm bellows tear in an Ohmeda 7810 ventilator allows anesthetic gases to contaminate ambient air but does not cause clinically significant changes in Fio(2), exhaled Vt, PIP, or PEEP.

  4. Sleep and neuromuscular disease: bilevel positive airway pressure by nasal mask as a treatment for sleep disordered breathing in patients with neuromuscular disease

    PubMed Central

    Guilleminault, C.; Philip, P.; Robinson, A.

    1998-01-01

    OBJECTIVE—Investigation of the therapeutic effects of bilevel positive airway pressure delivered by nasal mask in patients with neuromuscular disease.
METHODS—20 patients with neuromuscular disease were evaluated for symptoms of nocturnal sleep disruption. These symptoms included daytime tiredness, fatigue, sleepiness, and complaints of insomnia. The patients were studied with nocturnal polysomnograms and daytime multiple sleep latency tests (MSLT). Their immediate and long term responses to bilevel positive airway pressure were also investigated. The study took place at the Stanford University Sleep Disorders Clinic. Some of the polygraphic evaluations were performed with portable equipment in the patients' homes. The reported population comprised 20 patients, all of whom had progressive neuromuscular disease. Five of the patients were women. Four patients had muscular dystrophy, six had myotonic dystrophy, and two patients each had mitochondrial myopathy and glycogen storage disease. Two patients had post-traumatic lesions, one bulbar and the other phrenic. The remaining patients had vascular myopathy, unclassified myopathy, syringomyelia, and slow evolving spinocerebellar degeneration.
RESULTS—19 of the 20 patients accepted some form of non-invasive ventilation. All but one of these were initially maintained on bilevel positive airway pressure spontaneous (S) mode, although one patient required a switch to the timed (T) mode within a year. The mean expiratory positive airway pressure (EPAP) used was 4.5 with a range of 4 to 5 cm H2O. The mean inspiratory positive airway pressure (IPAP) was 11.5, range 9 to 14 cm H2O. Before treatment the MSLTs were ⩽ 8 minutes in 11 of the patients. The overall mean score was 8.2 (SD) 1.3 minutes. After long term treatment the mean MSLT was 12.5 (SD 2) minutes and the mean ESS score was 7 (SD 3). During the mean 3.5 years of follow up, three patients needed supplemental oxygen at a flow of 0.5 to 1.0 l/min bled into

  5. [Pulmonary mechanics and small airways in patent ductus arteriosus and interventricular communication, in relation to pulmonary arterial flow and pressure].

    PubMed

    Martínez-Guerra, M L; Fernández-Bonetti, P; Peraza, C; Lupi-Herrera, E

    1982-01-01

    Eighteen patients with ventricular septal defect or patent ductus arteriosus were studied to investigate the effects of an increase of pulmonary hypertension. In general group II showed similar results as previously reported in patients with atrial septal defect without pulmonary hypertension. In group I, we found an increased frequency of functional abnormalities in the small airways. We do not have a definitive explanation for the origin of these differences.

  6. Web-Based Access to Positive Airway Pressure Usage with or without an Initial Financial Incentive Improves Treatment Use in Patients with Obstructive Sleep Apnea

    PubMed Central

    Kuna, Samuel T.; Shuttleworth, David; Chi, Luqi; Schutte-Rodin, Sharon; Friedman, Eliot; Guo, Hengyi; Dhand, Sandeep; Yang, Lin; Zhu, Jingsan; Bellamy, Scarlett L.; Volpp, Kevin G.; Asch, David A.

    2015-01-01

    Study Objectives: We tested whether providing adults with obstructive sleep apnea (OSA) with daily Web-based access to their positive airway pressure (PAP) usage over 3 mo with or without a financial incentive in the first week improves adherence and functional outcomes. Setting: Academic- and community-based sleep centers. Participants: One hundred thirty-eight adults with newly diagnosed OSA starting PAP treatment. Interventions: Participants were randomized to: usual care, usual care with access to PAP usage, or usual care with access to PAP usage and a financial incentive. PAP data were transmitted daily by wireless modem from the participants' PAP unit to a website where hours of usage were displayed. Participants in the financial incentive group could earn up to $30/day in the first week for objective PAP use ≥ 4 h/day. Measurements and Results: Mean hours of daily PAP use in the two groups with access to PAP usage data did not differ from each other but was significantly greater than that in the usual care group in the first week and over 3 mo (P < 0.0001). Average daily use (mean ± standard deviation) during the first week of PAP intervention was 4.7 ± 3.3 h in the usual care group, and 5.9 ± 2.5 h and 6.3 ± 2.5 h in the Web access groups with and without financial incentive respectively. Adherence over the 3-mo intervention decreased at a relatively constant rate in all three groups. Functional Outcomes of Sleep Questionnaire change scores at 3 mo improved within each group (P < 0.0001) but change scores of the two groups with Web access to PAP data were not different than those in the control group (P > 0.124). Conclusions: Positive airway pressure adherence is significantly improved by giving patients Web access to information about their use of the treatment. Inclusion of a financial incentive in the first week had no additive effect in improving adherence. Citation: Kuna ST, Shuttleworth D, Chi L, Schutte-Rodin S, Friedman E, Guo H, Dhand S, Yang

  7. Effect of Positive Airway Pressure Therapy on Body Mass Index in Obese Patients With Obstructive Sleep Apnea Syndrome: A Prospective Study.

    PubMed

    Rishi, Muhammad Adeel; Copur, Ahmet Sinan; Nadeem, Rashid; Fulambarker, Ashok

    2016-01-01

    Because obesity is a common cause of obstructive sleep apnea syndrome (OSAS), weight loss can be an effective treatment. OSAS also may cause weight gain in some patients. Effective treatment of sleep apnea may facilitate weight loss in obese patients. We hypothesize that positive airway pressure (PAP) therapy is associated with weight loss in obese patients with OSAS. This was a single-center observational prospective cohort study. Forty-five patients were diagnosed with OSAS after polysomnographic analysis in sleep laboratory and underwent continuous positive airway pressure titration. Patients were followed for 3 months in terms of change in body mass index (BMI) and compliance with PAP therapy. Of the 45 patients recruited, 3 patients were eliminated because of miss recruitment. Nine patients had incomplete data, and the rest (n = 33) were included for analysis. The mean age was 54.9 ± 16.9 years (mean ± SD), 93.9% were male, and 90.9% were whites. Mean apnea-hypopnea index was 36.3 ± 28.17 events per hour. Mean BMI before treatment was 34.7 ± 3.9 kg/m. Fifteen patients (45.5%) were compliant with therapy of OSAS with PAP. There was no difference in age, gender, neck circumference, BMI, and apnea-hypopnea index of patients compliant to therapy when compared with those who were not. There was a significant decrease in BMI in patients compliant with PAP therapy compared with noncompliant patients (-1.2 ± 0.7 vs. 0.3 ± 0.9 kg/m, P ≤ 0.001). PAP therapy may cause significant loss of weight within 3 months in obese patients with OSAS. Further study is needed to elucidate the physiological basis of this change.

  8. Randomized controlled trial of discontinuation of nasal-CPAP in stable preterm infants breathing room air.

    PubMed

    Abdel-Hady, H; Mohareb, S; Khashaba, M; Abu-Alkhair, M; Greisen, G

    1998-01-01

    This trial assessed the consequences of discontinuation of nasal-CPAP in stable preterm infants breathing room air. Eighty-eight infants with a mean gestational age of 29 (24-33) weeks and a mean birthweight of 1264 (665-2060)g, randomized to either discontinuation of CPAP or its continuation, were clinically observed and monitored for 6 h by cardiorespiratory monitor, pulse oximeter and transcutaneous blood gas monitor. The abdominal circumference and gastric air and aspirate volumes were measured prior to meals at trial entry and after 6 h. Discontinuation of CPAP led to a small but significant decrease in oxygenation at 1 and 6 h. During the trial, five infants in the experimental group required supplemental oxygen and one infant was put back on CPAP owing to excessive apnoeas. Discontinuation of CPAP did not influence the TcPCO2 or the number of apnoeas and bradycardias during the trial, but led to significantly increased respiratory rate, retractions, and flaring at 6 h. It also led to a significant decrease in the abdominal circumference and gastric air volume. Thirty-nine percent of infants were put back on CPAP some time after the trial, mainly because of recurrent apnoeas and bradycardias. Taking the infant off CPAP during the trial reduced subsequent use of CPAP.

  9. The Association between Obstructive Sleep Apnea and Neurocognitive Performance—The Apnea Positive Pressure Long-term Efficacy Study (APPLES)

    PubMed Central

    Quan, Stuart F.; Chan, Cynthia S.; Dement, William C.; Gevins, Alan; Goodwin, James L.; Gottlieb, Daniel J.; Green, Sylvan; Guilleminault, Christian; Hirshkowitz, Max; Hyde, Pamela R.; Kay, Gary G.; Leary, Eileen B.; Nichols, Deborah A.; Schweitzer, Paula K.; Simon, Richard D.; Walsh, James K.; Kushida, Clete A.

    2011-01-01

    Study Objectives: To determine associations between obstructive sleep apnea (OSA) and neurocognitive performance in a large cohort of adults. Study Design: Cross-sectional analyses of polysomnographic and neurocognitive data from 1204 adult participants with a clinical diagnosis of obstructive sleep apnea (OSA) in the Apnea Positive Pressure Long-term Efficacy Study (APPLES), assessed at baseline before randomization to either continuous positive airway pressure (CPAP) or sham CPAP. Measurements: Sleep and respiratory indices obtained by laboratory polysomnography and several measures of neurocognitive performance. Results: Weak correlations were found for both the apnea hypopnea index (AHI) and several indices of oxygen desaturation and neurocognitive performance in unadjusted analyses. After adjustment for level of education, ethnicity, and gender, there was no association between the AHI and neurocognitive performance. However, severity of oxygen desaturation was weakly associated with worse neurocognitive performance on some measures of intelligence, attention, and processing speed. Conclusions: The impact of OSA on neurocognitive performance is small for many individuals with this condition and is most related to the severity of hypoxemia. Citation: Quan SF; Chan CS; Dement WC; Gevins A; Goodwin JL; Gottlieb DJ; Green S; Guilleminault C; Hirshkowitz M; Hype PR; Kay GG; Leary EB; Nichols DA; Schweitzer PK; Simon RD; Walsh JK; Kushida CA. The association between obstructive sleep apnea and neurocognitive performance—the Apnea Positive Pressure Long-term Efficacy Study (APPLES). SLEEP 2011;34(3):303-314. PMID:21358847

  10. Improved Oxygenation 24 Hours After Transition to Airway Pressure Release Ventilation or High-Frequency Oscillatory Ventilation Accurately Discriminates Survival in Immunocompromised Pediatric Patients With Acute Respiratory Distress Syndrome*

    PubMed Central

    Yehya, Nadir; Topjian, Alexis A.; Thomas, Neal J.; Friess, Stuart H.

    2014-01-01

    Objectives Children with an immunocompromised condition and requiring invasive mechanical ventilation have high risk of death. Such patients are commonly transitioned to rescue modes of non-conventional ventilation, including airway pressure release ventilation and high-frequency oscillatory ventilation, for acute respiratory distress syndrome refractory to conventional ventilation. Our aim was to describe our experience with airway pressure release ventilation and high-frequency oscillatory ventilation in children with an immunocompromised condition and acute respiratory distress syndrome refractory to conventional ventilation and to identify factors associated with survival. Design Retrospective cohort study. Setting Tertiary care, university-affiliated PICU. Patients Sixty pediatric patients with an immunocompromised condition and acute respiratory distress syndrome refractory to conventional ventilation transitioned to either airway pressure release ventilation or high-frequency oscillatory ventilation. Interventions None. Measurements and Main Results Demographic data, ventilator settings, arterial blood gases, oxygenation index, and Pao2/Fio2 were recorded before transition to either mode of nonconventional ventilation and at predetermined intervals after transition for up to 5 days. Mortality in the entire cohort was 63% and did not differ between patients transitioned to airway pressure release ventilation and high-frequency oscillatory ventilation. For both airway pressure release ventilation and high-frequency oscillatory ventilation, improvements in oxygenation index and Pao2/Fio2 at 24 hours expressed as a fraction of pretransition values (oxygenation index24/oxygenation indexpre and Pao2/Fio224/Pao2/FIO2pre) reliably discriminated nonsurvivors from survivors, with receiver operating characteristic areas under the curves between 0.89 and 0.95 (p for all curves < 0.001). Sensitivity-specificity analysis suggested that less than 15% reduction in

  11. Pre- and in-therapy predictive score models of adult OSAS patients with poor adherence pattern on nCPAP therapy

    PubMed Central

    Wang, Yeying; Geater, Alan F; Chai, Yanling; Luo, Jiahong; Niu, Xiaoqun; Hai, Bing; Qin, Jingting; Li, Yongxia

    2015-01-01

    Objectives To identify patterns of adherence to nasal continuous positive airway pressure (nCPAP) use in the first 3 months of therapy among newly diagnosed adult patients with obstructive sleep apnea/hypopnea syndrome (OSAS) and their predictors. To develop pretherapy and in-therapy scores to predict adherence pattern. Methods Newly diagnosed adult OSAS patients were consecutively recruited from March to August 2013. Baseline clinical information and measures such as Epworth Sleepiness Scale (ESS), Fatigue Severity Scale (FSS), Zung’s Self-Rating Depression Scale (SDS), and The Pittsburgh Sleep Quality Index (PSQI) at baseline and at the end of 3rd-week therapy were collected. Twelve weeks’ adherence data were collected from the nCPAP memory card, and K-means cluster analysis was used to explore adherence patterns. Predictive scores were developed from the coefficients of cumulative logit models of adherence patterns using variables available at baseline and after 3 weeks of therapy. Performance of the score was validated using 500 bootstrap resamples. Results Seventy six patients completed a 12-week follow-up. Three patterns were revealed. Patients were identified as developing an adherence pattern that was poor (n=14, mean ± SD, 2.3±0.9 hours per night), moderate (n=19, 5.3±0.6 hours per night), or good (n=43, 6.8±0.3 hours per night). Cumulative logit regression models (good → moderate → poor) revealed independent baseline predictors to be ESS (per unit increase) (OR [95% CI], 0.763 [0.651, 0.893]), SDS (1.461 [1.238, 1.724]), and PSQI (2.261 [1.427, 3.584]); and 3-week therapy predictors to be ESS (0.554 [0.331, 0.926]), PSQI (2.548 [1.454, 4.465]), and the changes (3rd week–baseline data) in ESS (0.459 [0.243, 0.868]), FSS (3.556 [1.788, 7.070]), and PSQI (2.937 [1.273, 6.773]). Two predictive score formulas for poor adherence were developed. The area under the curve (AUC) of the receiver operating characteristics (ROC) curves for baseline and 3

  12. Comparison of Four Different Supraglottic Airway Devices in Terms of Efficacy, Intra-ocular Pressure and Haemodynamic Parameters in Children Undergoing Ophthalmic Surgery

    PubMed Central

    Peker, Gökhan; Takmaz, Suna Akın; Baltacı, Bülent; Başar, Hülya; Kotanoğlu, Mustafa

    2015-01-01

    Objective The aim of this study was to compare insertion parameters of four different types of supraglottic airway devices (SGAD) (Classic LMA, I-gel LMA, Proseal LMA, Cobra PLA) in children undergoing ophthalmic surgery and to determine the effect on intra-ocular pressure (IOP) and haemodynamic responses during insertion. Methods Sixty American society of Anesthesiologists (ASA) I–II children aged 1–10 years undergoing extra-ocular ophthalmic surgery were randomly divided into four groups (Group LMA, Group I-gel LMA, Group PLMA and Group CPLA) in this prospective, randomised study. Anaesthesia was induced with decreasing sevoflurane concentrations (8%–2%) in a mixture of 50% N2O-O2. All SGADs were inserted under deep anaesthesia. The characteristics of insertion (number of attempts, ease and time), oropharyngeal leak pressure (OLP) and complications were recorded. IOP in both eyes, heart rate (HR), mean arterial pressure (MAP) and EtCO2 were measured before and 2 and 5 min after insertion of the SGADs. Results There was no difference between the groups in terms of the characteristics of insertion. The mean IOP did not increase significantly in all groups. MAP and HR changes were similar among the groups during follow-up. In all groups, HR increased 2 min after insertion (statistically insignificant) and returned to the baseline value 5 min after insertion. A statistically significant correlation was seen between HR increase and IOP values before and after insertion of the SGADs (p=0.006, correlation coefficient=0.352). Desaturation was seen in one patient in Groups LMA, PLMA and CPLA, and laryngospasm was seen in two patients in Group CPLA and in one patient in Group LMA. Conclusion It was seen that during insertion of Classic LMA, I-gel LMA, Proseal LMA and Cobra PLA, IOP did not increase and haemodynamic stability was maintained in children undergoing extra-ocular ophthalmic surgery. PMID:27366519

  13. Volumetric three-dimensional computed tomographic evaluation of the upper airway in patients with obstructive sleep apnoea syndrome treated by maxillomandibular advancement.

    PubMed

    Bianchi, Alberto; Betti, Enrico; Tarsitano, Achille; Morselli-Labate, Antonio Maria; Lancellotti, Lorenzo; Marchetti, Claudio

    2014-11-01

    Obstructive sleep apnoea syndrome is the periodic reduction or cessation of airflow during sleep together with daytime sleepiness. Its diagnosis requires polysomnographic evidence of 5 or more episodes of apnoea or hypopnoea/hour of sleep (apnoea/hypopnoea index, AHI). Volumetric 3-dimensional computed tomographic (CT) reconstruction enables the accurate measurement of the volume of the airway. Nasal continuous positive airway pressure (CPAP) is the conventional non-surgical treatment for patients with severe disease. Operations on the soft tissues that are currently available give success rates of only 40%-60%. Maxillomandibular advancement is currently the most effective craniofacial surgical technique for the treatment of obstructive sleep apnoea in adults. However, the appropriate distance for advancement has not been established. Expansion of the air-flow column volume did not result in an additional reduction in AHI, which raises the important issue of how much the maxillomandibular complex should be advanced to obtain an adequate reduction in AHI while avoiding the risks of overexpansion or underexpansion. We have shown that there is a significant linear relation between increased absolute upper airway volume after advancement and improvement in the AHI (p=0.013). However, increases in upper airway volume of 70% or more achieved no further reduction in the AHI, which suggests that the clinical improvement in AHI reaches a plateau, and renders further expansion unnecessary. This gives a new perspective to treatment based on the prediction of changes in volume, so the amount of sagittal advancement can be tailored in each case, which replaces the current standard of 1cm.

  14. The effect of treating obstructive sleep apnea with positive airway pressure on depression and other subjective symptoms: A systematic review and meta-analysis.

    PubMed

    Gupta, Madhulika A; Simpson, Fiona C; Lyons, Danika C A

    2016-08-01

    Patients with obstructive sleep apnea (OSA) frequently present with symptoms of depression and anxiety. The objective of this study is to determine if treatment with positive airway pressure (PAP) improves symptoms of depression and anxiety. A systematic review was conducted to identify clinical trials of PAP that contained a validated measure of depression severity. Meta-analysis was conducted for depression, anxiety, excessive daytime sleepiness (EDS), quality of life (QoL) and respiratory variables. The systematic review included 33 reports. Pre-post-test analysis of PAP showed a moderate effect size (Hedge's g, 95% CI) for depression 0.524 [0.401-0.647], but a low effect size compared to oral placebo (0.355 [0.187-0.524]) and no effect when compared to dental appliances (0.107 [-0.72-0.287]) and sham PAP (-0.049 [-0.292-0.194]). Anxiety, EDS, and QoL showed similar improvement in pre-post-test analysis, but a lack of superiority to dental appliances and sham PAP. PAP was superior to all comparators for respiratory variables. PAP has a moderate clinical effect on symptoms of depression and anxiety in OSA, but it is not superior to dental appliances or sham PAP. The improvement in subjective symptoms, such as depression and anxiety, may be mediated by patient expectations and contact with healthcare providers.

  15. Acute Effects of Continuous Positive Air way Pressure on Pulse Pressure in Chronic Heart Failure

    PubMed Central

    Quintão, Mônica; Chermont, Sérgio; Marchese, Luana; Brandão, Lúcia; Bernardez, Sabrina Pereira; Mesquita, Evandro Tinoco; Rocha, Nazareth de Novaes; Nóbrega, Antônio Claudio L.

    2014-01-01

    Background Patients with heart failure (HF) have left ventricular dysfunction and reduced mean arterial pressure (MAP). Increased adrenergic drive causes vasoconstriction and vessel resistance maintaining MAP, while increasing peripheral vascular resistance and conduit vessel stiffness. Increased pulse pressure (PP) reflects a complex interaction of the heart with the arterial and venous systems. Increased PP is an important risk marker in patients with chronic HF (CHF). Non-invasive ventilation (NIV) has been used for acute decompensated HF, to improve congestion and ventilation through both respiratory and hemodynamic effects. However, none of these studies have reported the effect of NIV on PP. Objective The objective of this study was to determine the acute effects of NIV with CPAP on PP in outpatients with CHF. Methods Following a double-blind, randomized, cross-over, and placebo-controlled protocol, twenty three patients with CHF (17 males; 60 ± 11 years; BMI 29 ± 5 kg/cm2, NYHA class II, III) underwent CPAP via nasal mask for 30 min in a recumbent position. Mask pressure was 6 cmH2O, whereas placebo was fixed at 0-1 cmH2O. PP and other non invasive hemodynamics variables were assessed before, during and after placebo and CPAP mode. Results CPAP decreased resting heart rate (Pre: 72 ± 9; vs. Post 5 min: 67 ± 10 bpm; p < 0.01) and MAP (CPAP: 87 ± 11; vs. control 96 ± 11 mmHg; p < 0.05 post 5 min). CPAP decreased PP (CPAP: 47 ± 20 pre to 38 ± 19 mmHg post; vs. control: 42 ± 12 mmHg, pre to 41 ± 18 post p < 0.05 post 5 min). Conclusion NIV with CPAP decreased pulse pressure in patients with stable CHF. Future clinical trials should investigate whether this effect is associated with improved clinical outcome. PMID:24676373

  16. Estimation of airway obstruction using oximeter plethysmograph waveform data

    PubMed Central

    Arnold, Donald H; Spiro, David M; Desmond, Renee' A; Hagood, James S

    2005-01-01

    Background Validated measures to assess the severity of airway obstruction in patients with obstructive airway disease are limited. Changes in the pulse oximeter plethysmograph waveform represent fluctuations in arterial flow. Analysis of these fluctuations might be useful clinically if they represent physiologic perturbations resulting from airway obstruction. We tested the hypothesis that the severity of airway obstruction could be estimated using plethysmograph waveform data. Methods Using a closed airway circuit with adjustable inspiratory and expiratory pressure relief valves, airway obstruction was induced in a prospective convenience sample of 31 healthy adult subjects. Maximal change in airway pressure at the mouthpiece was used as a surrogate measure of the degree of obstruction applied. Plethysmograph waveform data and mouthpiece airway pressure were acquired for 60 seconds at increasing levels of inspiratory and expiratory obstruction. At each level of applied obstruction, mean values for maximal change in waveform area under the curve and height as well as maximal change in mouth pressure were calculated for sequential 7.5 second intervals. Correlations of these waveform variables with mouth pressure values were then performed to determine if the magnitude of changes in these variables indicates the severity of airway obstruction. Results There were significant relationships between maximal change in area under the curve (P < .0001) or height (P < 0.0001) and mouth pressure. Conclusion The findings suggest that mathematic interpretation of plethysmograph waveform data may estimate the severity of airway obstruction and be of clinical utility in objective assessment of patients with obstructive airway diseases. PMID:15985171

  17. The Phillips airway.

    PubMed

    Haridas, R P; Wilkinson, D J

    2012-07-01

    The Phillips airway was developed by George Ramsay Phillips. There is no known original description of the airway and the earliest known reference to it is from 1919. The airway and its modifications are described.

  18. Blockage of upper airway

    MedlinePlus

    ... Airway obstruction - acute upper Images Throat anatomy Choking Respiratory system References Cukor J, Manno M. Pediatric respiratory emergencies: upper airway obstruction and infections. In: Marx ...

  19. The Effects of Massage with Coconut and Sunflower Oils on Oxygen Saturation of Premature Infants with Respiratory Distress Syndrome Treated With Nasal Continuous Positive Airway Pressure

    PubMed Central

    Valizadeh, Sousan; Hosseini, Mohammad Bagher; Asghari Jafarabadi, Mohammad; Ajoodanian, Najmeh

    2012-01-01

    Introduction: Nowadays particular emphasis is placed on the developmental aspects of premature infants care. Massage therapy is one of the best-known methods of caring. Due to the minimal touch policy in neonatal intensive care units (NICUs), massaging is not usually performed on premature infants. However, there is not sufficient evidence to support the claim that newborn infants with complex medical conditions should not be massaged. This study aimed to determine the effects of massage with coconut and sunflower oils on oxygen saturation of infants with respiratory distress syndrome (RDS) treated with nasal continuous positive airway pressure (NCPAP). Methods: This was a randomized controlled trial on 90 newborns who were admitted to Alzahra Hospital (Tabriz, Iran). The infants were divided into control and massage therapy groups (massage with coconut and sunflower oils). Data was collected using a hospital documentation form. A 15-minute daily massage was performed for 3 days. Respiratory rate (RR), fraction of inspired oxygen (FiO2) and oxygen saturation were measured 5 minutes before the massage, 3 times during the massage, and 5 minutes after the massage. The collected data was analyzed using a mixed model. Results: In comparison to coconut oil and control groups, mean oxygen saturation of sunflower oil group was improved. In addition, the coconut massage group showed lower oxygen saturation than the control group but was all values were within the normal range. Although massage decreased oxygen saturation, there was no need to increase FiO2. Conclusion: Massage therapy can provide developmental care for infants treated with NCPAP. PMID:25276695

  20. Postoperative pharyngolaryngeal adverse events with laryngeal mask airway (LMA Supreme) in laparoscopic surgical procedures with cuff pressure limiting 25 cmH₂O: prospective, blind, and randomised study.

    PubMed

    Kang, Joo-Eun; Oh, Chung-Sik; Choi, Jae Won; Son, Il Soon; Kim, Seong-Hyop

    2014-01-01

    To reduce the incidence of postoperative pharyngolaryngeal adverse events, laryngeal mask airway (LMA) manufacturers recommend maximum cuff pressures not exceeding 60 cmH₂O. We performed a prospective randomised study, comparing efficacy and adverse events among patients undergoing laparoscopic surgical procedures who were allocated randomly into low (limiting 25 cmH₂O, L group) and high (at 60 cmH₂O, H group) LMA cuff pressure groups with LMA Supreme. Postoperative pharyngolaryngeal adverse events were evaluated at discharge from postanaesthetic care unit (PACU) (postoperative day 1, POD 1) and 24 hours after discharge from PACU (postoperative day 2, POD 2). All patients were well tolerated with LMA without ventilation failure. Before pneumoperitoneum, cuff volume and pressure and oropharyngeal leak pressure (OLP) showed significant differences. Postoperative sore throat at POD 2 (3 versus 12 patients) and postoperative dysphagia at POD 1 and POD 2 (0 versus 4 patients at POD 1; 0 versus 4 patients at POD 2) were significantly lower in L group, compared with H group. In conclusion, LMA with cuff pressure limiting 25 cmH₂O allowed both efficacy of airway management and lower incidence of postoperative adverse events in laparoscopic surgical procedures. This clinical trial is registered with KCT0000334.

  1. Bio-markers of oxidative stress following CPAP-withdrawal: data from two randomized trials

    PubMed Central

    Stradling, John R; Schwarz, Esther I; Schlatzer, Christian; Manuel, Ari R; Lee, Regent; Antoniades, Charalambos; Kohler, Malcolm

    2015-01-01

    There is conflicting evidence whether intermittent hypoxia in OSA influences oxidative stress. We hypothesized that withdrawal of CPAP from patients with OSA would raise markers of oxidative stress. 59 patients with CPAP-treated moderate-to-severe OSA (ODI, >20/hour) were randomized 1:1 to either stay on CPAP (n=30), or change to sham CPAP (n=29) for 2 weeks. Using samples from two similar studies at two sites, we measured early morning blood malondialdehyde (MDA, a primary outcome in one study, secondary in the other), lipid hydroperoxides, total anti-oxidant capacity, superoxide generation from mononuclear cells, and urinary F2-isoprostane. We also measured superoxide dismutase as a marker of hypoxic pre-conditioning. ‘Treatment’ effects (sham CPAP versus CPAP) were calculated via linear regression. Sham CPAP provoked moderate-to-severe OSA (mean ODI 46/hour), but blood markers of oxidative stress did not change significantly (MDA ‘treatment’ effect [95%CIs], −0.02 [−0.23 to +0.19] μmol/l). Urinary F2-isoprostane fell significantly approximately 30% (−0.26 [−0.42 to −0.10] ng/ml), and superoxide dismutase rose similarly (+0.17 [+0.02 to +0.30] ng/ml). We found no direct evidence of increased oxidative stress in patients experiencing a return of their moderate-to-severe OSA. The fall in urinary F2-isoprostane, and rise in superoxide dismutase, implies that hypoxic pre-conditioning may have reduced oxidative stress. PMID:26022961

  2. CPAP promotes timely cilium disassembly to maintain neural progenitor pool.

    PubMed

    Gabriel, Elke; Wason, Arpit; Ramani, Anand; Gooi, Li Ming; Keller, Patrick; Pozniakovsky, Andrei; Poser, Ina; Noack, Florian; Telugu, Narasimha Swamy; Calegari, Federico; Šarić, Tomo; Hescheler, Jürgen; Hyman, Anthony A; Gottardo, Marco; Callaini, Giuliano; Alkuraya, Fowzan Sami; Gopalakrishnan, Jay

    2016-04-15

    A mutation in the centrosomal-P4.1-associated protein (CPAP) causes Seckel syndrome with microcephaly, which is suggested to arise from a decline in neural progenitor cells (NPCs) during development. However, mechanisms ofNPCs maintenance remain unclear. Here, we report an unexpected role for the cilium inNPCs maintenance and identifyCPAPas a negative regulator of ciliary length independent of its role in centrosome biogenesis. At the onset of cilium disassembly,CPAPprovides a scaffold for the cilium disassembly complex (CDC), which includes Nde1, Aurora A, andOFD1, recruited to the ciliary base for timely cilium disassembly. In contrast, mutatedCPAPfails to localize at the ciliary base associated with inefficientCDCrecruitment, long cilia, retarded cilium disassembly, and delayed cell cycle re-entry leading to premature differentiation of patientiPS-derivedNPCs. AberrantCDCfunction also promotes premature differentiation ofNPCs in SeckeliPS-derived organoids. Thus, our results suggest a role for cilia in microcephaly and its involvement during neurogenesis and brain size control.

  3. Airway management in emergency situations.

    PubMed

    Dörges, Volker

    2005-12-01

    Securing and monitoring the airway are among the key requirements of appropriate therapy in emergency patients. Failures to secure the airways can drastically increase morbidity and mortality of patients within a very short time. Therefore, the entire range of measures needed to secure the airway in an emergency, without intermediate ventilation and oxygenation, is limited to 30-40 seconds. Endotracheal intubation is often called the 'gold standard' for airway management in an emergency, but multiple failed intubation attempts do not result in maintaining oxygenation; instead, they endanger the patient by prolonging hypoxia and causing additional trauma to the upper airways. Thus, knowledge and availability of alternative procedures are also essential in every emergency setting. Given the great variety of techniques available, it is important to establish a well-planned, methodical protocol within the framework of an algorithm. This not only facilitates the preparation of equipment and the training of personnel, it also ensures efficient decision-making under time pressure. Most anaesthesia-related deaths are due to hypoxaemia when difficulty in securing the airway is encountered, especially in obstetrics during induction of anaesthesia for caesarean delivery. The most commonly occurring adverse respiratory events are failure to intubate, failure to recognize oesophageal intubation, and failure to ventilate. Thus, it is essential that every anaesthesiologist working on the labour and delivery ward is comfortable with the algorithm for the management of failed intubation. The algorithm for emergency airway management describing the sequence of various procedures has to be adapted to internal standards and to techniques that are available.

  4. Ventilation of Nonparalyzed Patients Under Anesthesia with Laryngeal Mask Airway, Comparison of Three Modes of Ventilation: Volume Controlled Ventilation, Pressure Controlled Ventilation, and Pressure Controlled Ventilation-volume Guarantee

    PubMed Central

    Ghabach, Maroun Badwi; El Hajj, Elie M.; El Dib, Rouba D.; Rkaiby, Jeanette M.; Matta, May S.; Helou, May R.

    2017-01-01

    Background: Pressure controlled ventilation (PCV) is the preferable mode of ventilation of nonparalyzed patients undergoing anesthesia with laryngeal mask airway (LMA) as compared to volume controlled ventilation (VCV) and spontaneously breathing patient. In this study, we compared the PC–volume guarantee (PC-VG) mode of ventilation with VCV and PCV modes. Materials and Methods: A total of 30 patients, American Society of Anesthesiologists (ASA) physical status Classes I and II, scheduled for elective surgery under general anesthesia with a classic LMA were ventilated, subsequently, with the three modes of ventilation: VCV, PCV, and PC-VG for 10 min each mode. Tidal volume set for all patients was 8 ml/kg of ideal body weight. Parameters measured with modes of ventilation include peak inspiratory pressure (PIP), compliance, measured tidal volume, O2 saturation, end-tidal CO2, and presence of an oropharyngeal leak. Results: The PIP was significantly higher with the application of VCV mode of ventilation than PCV and PC-VG modes. The compliance was significantly lower when using the mode of ventilation VCV than PCV and PC-VG. The PIP and the compliance were not statistically different between the PCV and PC-VG modes of ventilation. Conclusions: Ventilation of nonparalyzed patients with LMA under anesthesia with PC-VG is advantageous over VCV in reducing PIP and increasing lung compliance. No difference was noted between PCV and PC-VG in ASA Classes I or II under the adequate depth of anesthesia in patients with normal pulmonary function. PMID:28298784

  5. Triggers of airway inflammation.

    PubMed

    Kerrebijn, K F

    1986-01-01

    Most asthmatics have hyperresponsive airways. This makes them more sensitive than non-asthmatics to bronchoconstricting environmental exposures which, in their turn, may enhance responsiveness. Airway inflammation is considered to be a key determinant of airway hyperresponsiveness: the fact that chronic airway inflammation in cystic fibrosis does not lead to airway hyperresponsiveness of any importance indicates, however, that the role of airway inflammation is complex and incompletely elucidated. The main inducers of airway inflammation are viral infections, antigens, occupational stimuli and pollutants. Although exercise, airway cooling and hyper- or hypotonic aerosols are potent stimuli of bronchoconstriction, it is questionable if airway inflammation is involved in their mode of action. Each of the above-mentioned stimuli is discussed, with emphasis laid on the relation of symptoms to mechanisms.

  6. Emergency airway puncture

    MedlinePlus

    ... support for only a very short period of time. Alternative Names Needle cricothyrotomy Images Emergency airway puncture Cricoid cartilage Emergency airway puncture - series References Hebert RB, Bose S, Mace SE. Cricothyrotomy and ...

  7. Upper airway biopsy

    MedlinePlus

    ... upper airway Images Upper airway test Bronchoscopy Throat anatomy References Yung RC, Boss EF. Tracheobronchial endoscopy. In: Flint PW, Haughey BH, Lund LJ, et al, eds. Cummings Otolaryngology: Head & Neck Surgery. 5th ed. Philadelphia, PA: Elsevier Mosby; ...

  8. Identification of a novel microtubule-destabilizing motif in CPAP that binds to tubulin heterodimers and inhibits microtubule assembly.

    PubMed

    Hung, Liang-Yi; Chen, Hua-Ling; Chang, Ching-Wen; Li, Bor-Ran; Tang, Tang K

    2004-06-01

    We have previously identified a new centrosomal protein, centrosomal protein 4.1-associated protein (CPAP), which is associated with the gamma-tubulin complex. Here, we report that CPAP carries a novel microtubule-destabilizing motif that not only inhibits microtubule nucleation from the centrosome but also depolymerizes taxol-stabilized microtubules. Deletion mapping and functional analyses have defined a 112-residue CPAP that is necessary and sufficient for microtubule destabilization. This 112-residue CPAP directly recognizes the plus end of a microtubule and inhibits microtubule nucleation from the centrosome. Biochemical and functional analyses revealed that this 112-residue CPAP also binds to tubulin dimers, resulting in the destabilization of microtubules. Using the tetracycline-controlled system (tet-off), we observed that overexpression of this 112-residue CPAP inhibits cell proliferation and induces apoptosis after G2/M arrest. The possible mechanisms of how this 112-residue motif in CPAP that inhibits microtubule nucleation from the centrosome and disassembles preformed microtubules are discussed.

  9. Functional characterization of the microtubule-binding and -destabilizing domains of CPAP and d-SAS-4.

    PubMed

    Hsu, Wen-Bin; Hung, Liang-Yi; Tang, Chieh-Ju C; Su, Chia-Li; Chang, Yulin; Tang, Tang K

    2008-08-15

    We previously identified a novel centrosomal protein CPAP, which carries a 112-residue motif that is essential for microtubule destabilization. In this report, we define both the microtubule (MT) binding and destabilizing domains in human CPAP and analyze the mutations that affect its MT-destabilizing activity. Analysis of a series of CPAP truncated proteins showed that the MT-binding domain (MBD; residues 423-607) of CPAP is located next to its MT-destabilizing domain (MDD; residues 311-422). Site-specific mutagenesis revealed that the mutations that either disrupt the alpha-helical structure (Y341P, I346P, L348P, and triple-P) or alter the charge property (KR377EE) of the MDD significantly affect its MT-destabilizing ability. The activity for binding to a tubulin heterodimer was also significantly reduced in KR377EE mutant. Furthermore, we have analyzed the putative function of Drosophila d-SAS-4, a distant relative of human CPAP, which shares a conserved approximately 20-aa sequence with the MDD of CPAP. Our results show that mutations in this conserved sequence also eliminate d-SAS-4's MT-destabilizing activity, suggesting that d-SAS-4 and CPAP may play similar roles within cells.

  10. Careers in Airway Science.

    ERIC Educational Resources Information Center

    Federal Aviation Administration (DOT), Washington, DC.

    The Federal Aviation Administration (FAA) has initiated the Airway Science curriculum as a method of preparing the next generation of aviation technicians and managers. This document: (1) discusses the FAA's role in the Airway Science program; (2) describes some of the career fields that FAA offers to Airway Science graduates (air traffic control…

  11. Obstructive Sleep Apnoea Syndrome, Endothelial Function and Markers of Endothelialization. Changes after CPAP

    PubMed Central

    Sanchez Armengol, Angeles; Moreno-Luna, Rafael; Caballero-Eraso, Candela; Macher, Hada C.; Villar, Jose; Merino, Ana M; Castell, Javier; Capote, Francisco; Stiefel, Pablo

    2015-01-01

    Study objectives This study tries to assess the endothelial function in vivo using flow-mediated dilatation (FMD) and several biomarkers of endothelium formation/restoration and damage in patients with obstructive sleep apnoea (OSA) syndrome at baseline and after three months with CPAP therapy. Design Observational study, before and after CPAP therapy. Setting and Patients We studied 30 patients with apnoea/hypopnoea index (AHI) >15/h that were compared with themselves after three months of CPAP therapy. FMD was assessed non-invasively in vivo using the Laser-Doppler flowmetry. Circulating cell-free DNA (cf-DNA) and microparticles (MPs) were measured as markers of endothelial damage and the vascular endothelial growth factor (VEGF) was determined as a marker of endothelial restoration process. Measurements and results After three month with CPAP, FMD significantly increased (1072.26 ± 483.21 vs. 1604.38 ± 915.69 PU, p< 0.005) cf-DNA and MPs significantly decreased (187.93 ± 115.81 vs. 121.28 ± 78.98 pg/ml, p<0.01, and 69.60 ± 62.60 vs. 39.82 ± 22.14 U/μL, p<0.05, respectively) and VEGF levels increased (585.02 ± 246.06 vs. 641.11 ± 212.69 pg/ml, p<0.05). These changes were higher in patients with more severe disease. There was a relationship between markers of damage (r = -0.53, p<0.005) but not between markers of damage and restoration, thus suggesting that both types of markers should be measured together. Conclusions CPAP therapy improves FMD. This improvement may be related to an increase of endothelial restoration process and a decrease of endothelial damage. PMID:25815511

  12. Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases

    PubMed Central

    Wieczorek, Andrzej; Gaszynski, Tomasz

    2015-01-01

    Introduction There are some patients with severe respiratory disturbances like adult respiratory distress syndrome (ARDS) and suspicion of brain death, for whom typical performance of the apneic test is difficult to complete because of quick desaturation and rapid deterioration without effective ventilation. To avoid failure of brain death confirmation and possible loss of organ donation another approach to apneic test is needed. We present two cases of patients with clinical symptoms of brain death, with lung pathology (acute lung injury, ARDS, lung embolism and lung infection), in whom apneic tests for recognizing brain death were difficult to perform. During typical performance of apneic test involving the use of oxygen catheter for apneic oxygenation we observed severe desaturation with growing hypotension and hemodynamic destabilization. But with the use of Boussignac CPAP system all necessary tests were successfully completed, confirming the patient’s brain death, which gave us the opportunity to perform procedures for organ donation. The main reason of apneic test difficulties was severe gas exchange disturbances secondary to ARDS. Thus lack of positive end expiratory pressure during classical performance of apneic test leads to quick desaturation and rapid hemodynamic deterioration, limiting the observation period below dedicated at least 10-minute interval. Conclusion The Boussignac CPAP system may be an effective tool for performing transparent apneic test in case of serious respiratory disturbances, especially in the form of acute lung injury or ARDS. PMID:26124664

  13. Driving Simulator Performance Remains Impaired In Patients With Severe OSA after CPAP Treatment

    PubMed Central

    Vakulin, Andrew; Baulk, Stuart D.; Catcheside, Peter G.; Antic, Nick A.; van den Heuvel, Cameron J.; Dorrian, Jillian; McEvoy, R. Doug

    2011-01-01

    Study Objectives: To assess the effectiveness of CPAP treatment in improving 90-minute driving simulator performance in severe OSA patients compared to age/gender matched controls. Design: Driving simulator performance was assessed at baseline and 3 months later, with OSA patients treated with CPAP during the interval. Setting: University Teaching Hospital. Participants: Patients with severe OSA (n = 11) and control subjects without OSA (n = 9). Interventions: CPAP Measurements and Results: Simulator driving parameters of steering deviation, braking reaction time and crashes were measured at baseline and ∼3 months follow-up. At baseline, OSA subjects demonstrated significantly greater steering deviation compared to controls (mean [95% CI], OSA group, 49.9 cm [43.7 to 56.0 cm] vs control group, 34.9 cm [28.1 to 41.7 cm], p = 0.003). Following ∼3 months of CPAP treatment (mean ± SD 6.0 ± 1.4 h/night), steering deviation in OSA subjects improved by an average of 3.1 cm (CI, 1.4 to 4.9), p < 0.001, while no significant steering changes were observed in the control group. Despite the improvement, steering deviation in the OSA group remained significantly higher than in controls (OSA group, 46.7 cm [CI, 40.6 to 52.8 cm] vs control group, 36.1 cm [CI, 29.3 to 42.9 cm], p = 0.025). Conclusions: While driving simulator performance improved after ∼3 months of CPAP treatment with high adherence in patients with severe OSA, performance remained impaired compared to control subjects. These results add to the growing body of evidence that some neurobehavioral deficits in patients with severe OSA are not fully reversed by treatment. Further studies are needed to assess causes of residual driving simulator impairment and to determine whether this is associated with persistent elevated real-life accident risk. Trial Registration: Data presented in this manuscript was collected as part of a clinical trial “Experimental Investigations of Driving Impairment in Obstructive

  14. Safety and Efficacy of Oral Feeding in Infants with BPD on nasal CPAP

    PubMed Central

    Hanin, Melissa; Nuthakki, Sushma; Malkar, Manish B.; Jadcherla, Sudarshan

    2016-01-01

    Objective Safety and efficacy of oral feeding was examined in infants with bronchopulmonary dysplasia (BPD) on nasal continuous positive airway pressure (NCPAP). We hypothesized that repetitive oral feeding enhances aerodigestive outcomes and reduces resource utilization. Methods Data from infants with BPD (37–42 weeks post menstrual age) that were orally fed while on NCPAP (n=26) were compared with those that were exclusively gavage fed on NCPAP (n=27). Subject assignment was random and physician practice based. Specifically, we compared the differences in aero-digestive milestones, resource utilization and safety metrics. Results Demographic characteristics such as gender distribution, gestational age and birth weight, clinical characteristics such as frequency of intraventricular hemorrhage and patent ductus arteriosus needing surgical ligation were similar in both groups (p > 0.05). Characteristics of respiratory support and airway milestones were similar in both groups (p > 0.05). However, infants in NCPAP-oral fed group had earlier acquisition of full oral feeding milestone by 17 days (median) vs. infants who were not orally fed during NCPAP (p < 0.05). Discharge weights and the frequency of gastrostomy tube placement were also similar in both groups (p > 0.05). There were no tracheostomies in either group. There was no incidence of clinically significant aspiration pneumonia in infants during the period of the oral feeding while on NCPAP. Conclusion Controlled introduction of oral feedings in infants with BPD during NCPAP is safe and may accelerate the acquisition of oral feeding milestones. PMID:25380678

  15. CPAP Machines: Tips for Avoiding 10 Common Problems

    MedlinePlus

    ... for obstructive sleep apnea. It includes a small machine that supplies a constant and steady air pressure, ... this by using a "ramp" feature on the machine. This feature allows you to start with low ...

  16. Dynamics of Surfactant Liquid Plugs at Bifurcating Lung Airway Models

    NASA Astrophysics Data System (ADS)

    Tavana, Hossein

    2013-11-01

    A surfactant liquid plug forms in the trachea during surfactant replacement therapy (SRT) of premature babies. Under air pressure, the plug propagates downstream and continuously divides into smaller daughter plugs at continuously branching lung airways. Propagating plugs deposit a thin film on airway walls to reduce surface tension and facilitate breathing. The effectiveness of SRT greatly depends on the final distribution of instilled surfactant within airways. To understand this process, we investigate dynamics of splitting of surfactant plugs in engineered bifurcating airway models. A liquid plug is instilled in the parent tube to propagate and split at the bifurcation. A split ratio, R, is defined as the ratio of daughter plug lengths in the top and bottom daughter airway tubes and studied as a function of the 3D orientation of airways and different flow conditions. For a given Capillary number (Ca), orienting airways farther away from a horizontal position reduced R due to the flow of a larger volume into the gravitationally favored daughter airway. At each orientation, R increased with 0.0005 < Ca < 0.05. This effect diminished by decrease in airways diameter. This approach will help elucidate surfactant distribution in airways and develop effective SRT strategies.

  17. Impact of airway morphological changes on pulmonary flows in scoliosis

    NASA Astrophysics Data System (ADS)

    Farrell, James; Garrido, Enrique; Valluri, Prashant

    2016-11-01

    The relationship between thoracic deformity in scoliosis and lung function is poorly understood. In a pilot study, we reviewed computed tomography (CT) routine scans of patients undergoing scoliosis surgery. The CT scans were processed to segment the anatomy of the airways, lung and spine. A three-dimensional model was created to study the anatomical relationship. Preliminary analysis showed significant airway morphological differences depending on the anterior position of the spine. A computational fluid dynamics (CFD) study was also conducted on the airway geometry using the inspiratory scans. The CFD model assuming non-compliant airway walls was capable of showing pressure drops in areas of high airway resistance, but was unable to predict regional ventilation differences. Our results indicate a dependence between the dynamic deformation of the airway during breathing and lung function. Dynamic structural deformation must therefore be incorporated within any modelling approaches to guide clinicians on the decision to perform surgical correction of the scoliosis.

  18. Modeling Upper Airway Collapse by a Finite Element Model with Regional Tissue Properties

    PubMed Central

    Xu, Chun; Brennick, Michael J.; Dougherty, Lawrence; Wootton, David M.

    2009-01-01

    This study presents a new computational system for modeling the upper airway in rats that combines tagged magnetic resonance imaging (MRI) with tissue material properties to predict three-dimensional (3D) airway motion. The model is capable of predicting airway wall and tissue deformation under airway pressure loading up to airway collapse. The model demonstrates that oropharynx collapse pressure depends primarily on ventral wall (tongue muscle) elastic modulus and airway architecture. An iterative approach that involves substituting alternative possible tissue elastic moduli was used to improve model precision. The proposed 3D model accounts for stress-strain relationships in the complex upper airway that should present new opportunities for understanding pathogenesis of airway collapse, improving diagnosis and developing treatments. PMID:19747871

  19. Mechanical Properties of the Upper Airway

    PubMed Central

    Strohl, Kingman P.; Butler, James P.; Malhotra, Atul

    2013-01-01

    The importance of the upper airway (nose, pharynx, and larynx) in health and in the pathogenesis of sleep apnea, asthma, and other airway diseases, discussed elsewhere in the Comprehensive Physiology series, prompts this review of the biomechanical properties and functional aspects of the upper airway. There is a literature based on anatomic or structural descriptions in static circumstances, albeit studied in limited numbers of individuals in both health and disease. As for dynamic features, the literature is limited to studies of pressure and flow through all or parts of the upper airway and to the effects of muscle activation on such features; however, the links between structure and function through airway size, shape, and compliance remain a topic that is completely open for investigation, particularly through analyses using concepts of fluid and structural mechanics. Throughout are included both historically seminal references, as well as those serving as signposts or updated reviews. This article should be considered a resource for concepts needed for the application of biomechanical models of upper airway physiology, applicable to understanding the pathophysiology of disease and anticipated results of treatment interventions. PMID:23723026

  20. A Computational Study of the Respiratory Airflow Characteristics in Normal and Obstructed Human Airways

    DTIC Science & Technology

    2014-01-01

    normal and three different obstructed airway geometries, consisting of symmetric, asym- metric, and random obstructions. Fig. 2 shows the geometric ...normal and obstructed airways Airway resistance is a measure of the opposition to the airflow caused by geometric properties, such as airway obstruction...pressure drops. Resistance values were dependent on the degree and geometric distribution of the obstruction sites. In the symmetric obstruction model

  1. Electron Microscopy Structural Insights into CPAP Oligomeric Behavior: A Plausible Assembly Process of a Supramolecular Scaffold of the Centrosome

    PubMed Central

    Alvarez-Cabrera, Ana L.; Delgado, Sandra; Gil-Carton, David; Mortuza, Gulnahar B.; Montoya, Guillermo; Sorzano, Carlos O. S.; Tang, Tang K.; Carazo, Jose M.

    2017-01-01

    Centrosomal P4.1-associated protein (CPAP) is a cell cycle regulated protein fundamental for centrosome assembly and centriole elongation. In humans, the region between residues 897–1338 of CPAP mediates interactions with other proteins and includes a homodimerization domain. CPAP mutations cause primary autosomal recessive microcephaly and Seckel syndrome. Despite of the biological/clinical relevance of CPAP, its mechanistic behavior remains unclear and its C-terminus (the G-box/TCP domain) is the only part whose structure has been solved. This situation is perhaps due in part to the challenges that represent obtaining the protein in a soluble, homogeneous state for structural studies. Our work constitutes a systematic structural analysis on multiple oligomers of HsCPAP897−1338, using single-particle electron microscopy (EM) of negatively stained (NS) samples. Based on image classification into clearly different regular 3D maps (putatively corresponding to dimers and tetramers) and direct observation of individual images representing other complexes of HsCPAP897−1338 (i.e., putative flexible monomers and higher-order multimers), we report a dynamic oligomeric behavior of this protein, where different homo-oligomers coexist in variable proportions. We propose that dimerization of the putative homodimer forms a putative tetramer which could be the structural unit for the scaffold that either tethers the pericentriolar material to centrioles or promotes procentriole elongation. A coarse fitting of atomic models into the NS 3D maps at resolutions around 20 Å is performed only to complement our experimental data, allowing us to hypothesize on the oligomeric composition of the different complexes. In this way, the current EM work represents an initial step toward the structural characterization of different oligomers of CPAP, suggesting further insights to understand how this protein works, contributing to the elucidation of control mechanisms for centriole

  2. Controversies in Pediatric Perioperative Airways

    PubMed Central

    Klučka, Jozef; Štourač, Petr; Štoudek, Roman; Ťoukálková, Michaela; Harazim, Hana; Kosinová, Martina

    2015-01-01

    Pediatric airway management is a challenge in routine anesthesia practice. Any airway-related complication due to improper procedure can have catastrophic consequences in pediatric patients. The authors reviewed the current relevant literature using the following data bases: Google Scholar, PubMed, Medline (OVID SP), and Dynamed, and the following keywords: Airway/s, Children, Pediatric, Difficult Airways, and Controversies. From a summary of the data, we identified several controversies: difficult airway prediction, difficult airway management, cuffed versus uncuffed endotracheal tubes for securing pediatric airways, rapid sequence induction (RSI), laryngeal mask versus endotracheal tube, and extubation timing. The data show that pediatric anesthesia practice in perioperative airway management is currently lacking the strong evidence-based medicine (EBM) data that is available for adult subpopulations. A number of procedural steps in airway management are derived only from adult populations. However, the objective is the same irrespective of patient age: proper securing of the airway and oxygenation of the patient. PMID:26759809

  3. Nonlinear Compliance Modulates Dynamic Bronchoconstriction in a Multiscale Airway Model

    PubMed Central

    Hiorns, Jonathan E.; Jensen, Oliver E.; Brook, Bindi S.

    2014-01-01

    The role of breathing and deep inspirations (DI) in modulating airway hyperresponsiveness remains poorly understood. In particular, DIs are potent bronchodilators of constricted airways in nonasthmatic subjects but not in asthmatic subjects. Additionally, length fluctuations (mimicking DIs) have been shown to reduce mean contractile force when applied to airway smooth muscle (ASM) cells and tissue strips. However, these observations are not recapitulated on application of transmural pressure (PTM) oscillations (that mimic tidal breathing and DIs) in isolated intact airways. To shed light on this paradox, we have developed a biomechanical model of the intact airway, accounting for strain-stiffening due to collagen recruitment (a large component of the extracellular matrix (ECM)), and dynamic actomyosin-driven force generation by ASM cells. In agreement with intact airway studies, our model shows that PTM fluctuations at particular mean transmural pressures can lead to only limited bronchodilation. However, our model predicts that moving the airway to a more compliant point on the static pressure-radius relationship (which may involve reducing mean PTM), before applying pressure fluctuations, can generate greater bronchodilation. This difference arises from competition between passive strain-stiffening of ECM and force generation by ASM yielding a highly nonlinear relationship between effective airway stiffness and PTM, which is modified by the presence of contractile agonist. Effectively, the airway at its most compliant may allow for greater strain to be transmitted to subcellular contractile machinery. The model predictions lead us to hypothesize that the maximum possible bronchodilation of an airway depends on its static compliance at the PTM about which the fluctuations are applied. We suggest the design of additional experimental protocols to test this hypothesis. PMID:25517167

  4. Patterns of recruitment and injury in a heterogeneous airway network model

    PubMed Central

    Stewart, Peter S.; Jensen, Oliver E.

    2015-01-01

    In respiratory distress, lung airways become flooded with liquid and may collapse due to surface-tension forces acting on air–liquid interfaces, inhibiting gas exchange. This paper proposes a mathematical multiscale model for the mechanical ventilation of a network of occluded airways, where air is forced into the network at a fixed tidal volume, allowing investigation of optimal recruitment strategies. The temporal response is derived from mechanistic models of individual airway reopening, incorporating feedback on the airway pressure due to recruitment. The model accounts for stochastic variability in airway diameter and stiffness across and between generations. For weak heterogeneity, the network is completely ventilated via one or more avalanches of recruitment (with airways recruited in quick succession), each characterized by a transient decrease in the airway pressure; avalanches become more erratic for airways that are initially more flooded. However, the time taken for complete ventilation of the network increases significantly as the network becomes more heterogeneous, leading to increased stresses on airway walls. The model predicts that the most peripheral airways are most at risk of ventilation-induced damage. A positive-end-expiratory pressure reduces the total recruitment time but at the cost of larger stresses exerted on airway walls. PMID:26423440

  5. Molecular basis for CPAP-tubulin interaction in controlling centriolar and ciliary length

    PubMed Central

    Zheng, Xiangdong; Ramani, Anand; Soni, Komal; Gottardo, Marco; Zheng, Shuangping; Ming Gooi, Li; Li, Wenjing; Feng, Shan; Mariappan, Aruljothi; Wason, Arpit; Widlund, Per; Pozniakovsky, Andrei; Poser, Ina; Deng, Haiteng; Ou, Guangshuo; Riparbelli, Maria; Giuliano, Callaini; Hyman, Anthony A.; Sattler, Michael; Gopalakrishnan, Jay; Li, Haitao

    2016-01-01

    Centrioles and cilia are microtubule-based structures, whose precise formation requires controlled cytoplasmic tubulin incorporation. How cytoplasmic tubulin is recognized for centriolar/ciliary-microtubule construction remains poorly understood. Centrosomal-P4.1-associated-protein (CPAP) binds tubulin via its PN2-3 domain. Here, we show that a C-terminal loop-helix in PN2-3 targets β-tubulin at the microtubule outer surface, while an N-terminal helical motif caps microtubule's α-β surface of β-tubulin. Through this, PN2-3 forms a high-affinity complex with GTP-tubulin, crucial for defining numbers and lengths of centriolar/ciliary-microtubules. Surprisingly, two distinct mutations in PN2-3 exhibit opposite effects on centriolar/ciliary-microtubule lengths. CPAPF375A, with strongly reduced tubulin interaction, causes shorter centrioles and cilia exhibiting doublet- instead of triplet-microtubules. CPAPEE343RR that unmasks the β-tubulin polymerization surface displays slightly reduced tubulin-binding affinity inducing over-elongation of newly forming centriolar/ciliary-microtubules by enhanced dynamic release of its bound tubulin. Thus CPAP regulates delivery of its bound-tubulin to define the size of microtubule-based cellular structures using a ‘clutch-like' mechanism. PMID:27306797

  6. Modeling the dynamics of airway constriction: effects of agonist transport and binding.

    PubMed

    Amin, Samir D; Majumdar, Arnab; Frey, Urs; Suki, Béla

    2010-08-01

    Recent advances have revealed that during exogenous airway challenge, airway diameters cannot be adequately predicted by their initial diameters. Furthermore, airway diameters can also vary greatly in time on scales shorter than a breath. To better understand these phenomena, we developed a multiscale model that allowed us to simulate aerosol challenge in the airways during ventilation. The model incorporates agonist-receptor binding kinetics to govern the temporal response of airway smooth muscle contraction on individual airway segments, which, together with airway wall mechanics, determines local airway caliber. Global agonist transport and deposition are coupled with pressure-driven flow, linking local airway constrictions with global flow dynamics. During the course of challenge, airway constriction alters the flow pattern, redistributing the agonist to less constricted regions. This results in a negative feedback that may be a protective property of the normal lung. As a consequence, repetitive challenge can cause spatial constriction patterns to evolve in time, resulting in a loss of predictability of airway diameters. Additionally, the model offers new insights into several phenomena including the intra- and interbreath dynamics of airway constriction throughout the tree structure.

  7. Indication of CPAP in Patients with Suspected Obstructive Sleep Apnea, Based on Clinical Parameters and a Novel Two-Channel Recording Device (ApneaLink): A Pilot Study

    PubMed Central

    Nigro, Carlos Alberto; Dibur, Eduardo; Grandval, Sofía; Nogueira, Facundo

    2012-01-01

    Objective. To evaluate the accuracy and reliability of the medical decision based on the results of the hand scoring from a two-channel recording device (ApneaLink) plus clinical data for the prescription of a CPAP assay in patients with suspected OSA. Methods. 39 subjects were assessed in the sleep laboratory with polysomnography and ApneaLink. The patients completed the Epworth sleepiness scale and a clinical history. Two blinded independent observers decided to prescribe CPAP according to the results of the PSG (gold standard, observer A), ApneaLink (alternative method, observer B), and the clinical parameters. Sensitivity and specificity of observer B on the indication of CPAP were calculated. The interobserver agreement for the indication of CPAP was assessed using kappa statistics. Results. 38 subjects were included (26 men, mean age 47.5, mean RDI 28.7, mean BMI 31.4 kg/m2). The prevalence of OSA was 84%. The sensitivity and specificity of observer B to initiate a CPAP trial were 90.6% and 100%, respectively. The interrater agreement for the prescription of CPAP was good (kappa: 0.75). Conclusion. This study has shown that the use of ApneaLink plus clinical data has made it possible to indicate CPAP reliably in most patients with high-clinical pretest for OSA. PMID:23470904

  8. Flow characteristics in the airways of a COPD patient with a saber-sheath trachea

    NASA Astrophysics Data System (ADS)

    Jin, Dohyun; Choi, Haecheon; Lee, Changhyun; Choi, Jiwoong; Kim, Kwanggi

    2016-11-01

    The chronic obstructive pulmonary disease (COPD) is a lung disease characterized by the irreversible airflow limitation caused by the damaged small airways and air sacs. Although COPD is not a disease of the trachea, many patients with COPD have saber-sheath tracheas. The effects of this morphological change in the trachea geometry on airflow are investigated in the present study. An unstructured finite volume method is used for the simulations during tidal breathing in normal and COPD airways, respectively. During inspiration, local large pressure drop is observed in the saber-sheath region of the COPD patient. During expiration, vortical structures are observed at the right main bronchus of the COPD airway, while the flow in the normal airway remains nearly laminar. High wall shear stress exists at convex regions of both airways during inspiration and expiration. However, due to the morphological changes in the COPD airway, relatively higher wall shear stress is observed in the patient airways.

  9. Airway evaluation in obstructive sleep apnea.

    PubMed

    Stuck, Boris A; Maurer, Joachim T

    2008-12-01

    As the interest in sleep-disordered breathing has increased, various attempts have been made to assess upper airway anatomy in patients with this relatively frequent disorder. The aim is not only to reveal potential differences in upper airway anatomy to better understand origin and pathophysiology of the disease but also to improve patient management and treatment success. The present review is based on a systematic literature search with regard to upper airway evaluation in sleep-disordered breathing; the articles were selected and discussed in light of our clinical experiences. Based on clinical assessment including endoscopy during wakefulness, the value of the Mueller Maneuver, static radiologic imaging techniques (X-ray cephalometry, computed tomography (CT) scanning and magnetic resonance imaging (MRI)), dynamic scanning protocols (e.g. ultrafast CT or cine MRI), upper airway endoscopy during sleep and sedated sleep, pressure measurements and the assessment of the critical closing pressure are discussed. Each technique itself and its history in the field of sleep medicine are briefly reviewed and problems of standardization and interpretation are discussed when appropriate. Insights into the pathophysiology of the disease gained with the help of the investigational techniques are presented and the impact of the techniques on patient management is reported. Although all these additional techniques for upper airway assessment have substantially improved our understanding of sleep-disordered breathing, their significance in daily practice is limited. In contrast to the widespread use of the Mueller maneuver and sedated endoscopy, convincing data supporting their use in terms of treatment outcome are lacking. So far, there is only very limited evidence that selected techniques improve treatment outcome for selected indications. In general, there is not enough evidence that these techniques are superior to the routine clinical assessment.

  10. What does airway resistance tell us about lung function?

    PubMed

    Kaminsky, David A

    2012-01-01

    Spirometry is considered the primary method to detect the air flow limitation associated with obstructive lung disease. However, air flow limitation is the end-result of many factors that contribute to obstructive lung disease. One of these factors is increased airway resistance. Airway resistance is traditionally measured by relating air flow and driving pressure using body plethysmography, thus deriving airway resistance (R(aw)), specific airway resistance (sR(aw)), and specific airway conductance (sG(aw)). Other methods to measure airway resistance include the forced oscillation technique (FOT), which allows calculation of respiratory system resistance (R(RS)) and reactance (X(RS)), and the interrupter technique, which allows calculation of interrupter resistance (R(int)). An advantage of these other methods is that they may be easier to perform than spirometry, making them particularly suited to patients who cannot perform spirometry, such as young children, patients with neuromuscular disorders, or patients on mechanical ventilation. Since spirometry also requires a deep inhalation, which can alter airway resistance, these alternative methods may provide more sensitive measures of airway resistance. Furthermore, the FOT provides unique information about lung mechanics that is not available from analysis using spirometry, body plethysmography, or the interrupter technique. However, it is unclear whether any of these measures of airway resistance contribute clinically important information to the traditional measures derived from spirometry (FEV(1), FVC, and FEV(1)/FVC). The purpose of this paper is to review the physiology and methodology of these measures of airway resistance, and then focus on their clinical utility in relation to each other and to spirometry.

  11. A multicentre, randomised controlled, non-inferiority trial, comparing high flow therapy with nasal continuous positive airway pressure as primary support for preterm infants with respiratory distress (the HIPSTER trial): study protocol

    PubMed Central

    Roberts, Calum T; Owen, Louise S; Manley, Brett J; Donath, Susan M; Davis, Peter G

    2015-01-01

    Introduction High flow (HF) therapy is an increasingly popular mode of non-invasive respiratory support for preterm infants. While there is now evidence to support the use of HF to reduce extubation failure, there have been no appropriately designed and powered studies to assess the use of HF as primary respiratory support soon after birth. Our hypothesis is that HF is non-inferior to the standard treatment—nasal continuous positive airway pressure (NCPAP)— as primary respiratory support for preterm infants. Methods and analysis The HIPSTER trial is an unblinded, international, multicentre, randomised, non-inferiority trial. Eligible infants are preterm infants of 28–36+6 weeks’ gestational age (GA) who require primary non-invasive respiratory support for respiratory distress in the first 24 h of life. Infants are randomised to treatment with either HF or NCPAP. The primary outcome is treatment failure within 72 h after randomisation, as determined by objective oxygenation, blood gas, and apnoea criteria, or the need for urgent intubation and mechanical ventilation. Secondary outcomes include the incidence of intubation, pneumothorax, bronchopulmonary dysplasia, nasal trauma, costs associated with hospital care and parental stress. With a specified non-inferiority margin of 10%, using a two-sided 95% CI and 90% power, the study requires 375 infants per group (total 750 infants). Ethics and dissemination Ethical approval has been granted by the relevant human research ethics committees at The Royal Women's Hospital (13/12), The Royal Children's Hospital (33144A), The Mercy Hospital for Women (R13/34), and the South-Eastern Norway Regional Health Authority (2013/1657). The trial is currently recruiting at 9 centres in Australia and Norway. The trial results will be published in peer-reviewed international journals, and presented at national and international conferences. Trial registration number Australian New Zealand Clinical Trials Registry ID: ACTRN

  12. Upper airway radiographs in infants with upper airway insufficiency.

    PubMed Central

    Tonkin, S L; Davis, S L; Gunn, T R

    1994-01-01

    Upper airway measurements in nine infants considered to be at risk of upper airway insufficiency, six of whom presented after an apnoeic episode, were compared with measurements taken in two age groups of healthy infants. Paired, inspiratory and expiratory, lateral upper airway radiographs were obtained while the infants were awake and breathing quietly. The radiographs of all nine infants demonstrated narrowing in the oropharyngeal portion of the airway during inspiration and in six infants there was ballooning of the upper airway during expiration. Seven of the nine infants subsequently experienced recurrent apnoeic episodes which required vigorous stimulation to restore breathing. Experience suggests that respiratory phase timed radiographs are a useful adjunct to the evaluation of infants who are suspected of having upper airway dysfunction. They provide information regarding both the dimensions and compliance of the upper airway as well as the site of any restriction. Images PMID:8048825

  13. Airway-parenchyma uncoupling in nocturnal asthma.

    PubMed

    Irvin, C G; Pak, J; Martin, R J

    2000-01-01

    Airway flow resistance is well known to be dependent upon lung volume. The rise in lung volume that occurs in asthma is therefore thought to be an important mechanism that defends airway patency. The purpose of the current study was to investigate the interdependence or mechanical coupling between airways and lung parenchyma during the inflammatory processes that occur in the patient with nocturnal asthma. Five patients with documented nocturnal asthma were studied in both a vertical and a horizontal body plethysmograph. Lung volume was altered with continuous negative pressure as applied to the chest wall with a poncho cuirass in different postures and during sleep. We found during the awake phase that an increase in lung volume decreased lower pulmonary resistance (Rlp); however, within 30 min of sleep onset, functional residual capacity (FRC) fell and Rlp rose more than would be expected for the fall in FRC. Restoring FRC to presleep values either at an early (half-hour) or a late (3-h) time point did not cause Rlp to significantly fall. A second phase of the study showed that the loss of Rlp dependence on lung volume was not due to the assumption of the supine posture. Indirect measurements of lung compliance were consistent with a stiffening of the lung. We conclude that with sleep there is an immediate uncoupling of the parenchyma to the airway, resulting in a loss of interdependence that persists throughout sleep and may contribute to the morbidity and mortality associated with nocturnal asthma.

  14. Conserved TCP domain of Sas-4/CPAP is essential for pericentriolar material tethering during centrosome biogenesis.

    PubMed

    Zheng, Xiangdong; Gooi, Li Ming; Wason, Arpit; Gabriel, Elke; Mehrjardi, Narges Zare; Yang, Qian; Zhang, Xingrun; Debec, Alain; Basiri, Marcus L; Avidor-Reiss, Tomer; Pozniakovsky, Andrei; Poser, Ina; Saric, Tomo; Hyman, Anthony A; Li, Haitao; Gopalakrishnan, Jay

    2014-01-21

    Pericentriolar material (PCM) recruitment to centrioles forms a key step in centrosome biogenesis. Deregulation of this process leads to centrosome aberrations causing disorders, one of which is autosomal recessive primary microcephaly (MCPH), a neurodevelopmental disorder where brain size is reduced. During PCM recruitment, the conserved centrosomal protein Sas-4/CPAP/MCPH6, known to play a role in centriole formation, acts as a scaffold for cytoplasmic PCM complexes to bind and then tethers them to centrioles to form functional centrosomes. To understand Sas-4's tethering role, we determined the crystal structure of its T complex protein 10 (TCP) domain displaying a solvent-exposed single-layer of β-sheets fold. This unique feature of the TCP domain suggests that it could provide an "extended surface-like" platform to tether the Sas-4-PCM scaffold to a centriole. Functional studies in Drosophila, human cells, and human induced pluripotent stem cell-derived neural progenitor cells were used to test this hypothesis, where point mutations within the 9-10th β-strands (β9-10 mutants including a MCPH-associated mutation) perturbed PCM tethering while allowing Sas-4/CPAP to scaffold cytoplasmic PCM complexes. Specifically, the Sas-4 β9-10 mutants displayed perturbed interactions with Ana2, a centrosome duplication factor, and Bld-10, a centriole microtubule-binding protein, suggesting a role for the β9-10 surface in mediating protein-protein interactions for efficient Sas-4-PCM scaffold centriole tethering. Hence, we provide possible insights into how centrosomal protein defects result in human MCPH and how Sas-4 proteins act as a vehicle to tether PCM complexes to centrioles independent of its well-known role in centriole duplication.

  15. Autoadjusting-CPAP effect on serum Leptin concentrations in Obstructive Sleep Apnoea patients

    PubMed Central

    Drummond, Marta; Winck, João C; Guimarães, João T; Santos, Ana C; Almeida, João; Marques, José A

    2008-01-01

    Background Leptin is an hormone that regulates body weight. Studies have shown increasing leptin concentrations according to body mass index (BMI) and intermittent hypoxia. Our aim is to evaluate the basal leptin levels in OSA patients and its possible relation to OSA severity, independently of confounders and investigate the Autoadjusting-CPAP effect on leptin values. Methods In ninety eight male patients with moderate to severe OSA leptin serum levels were evaluated before therapy, 9 days and 6 months after therapy. Results In this group mean age was 55.3 years, mean BMI was 33.2 Kg/m2 and mean Apnoea- Hypopnea Index (AHI) was 51.7/h. Mean basal serum leptin value was 12.1 ug/L. Univariate analysis showed a significant correlation between serum leptin values and BMI (R = 0.68; p < 0.001), waist-hip ratio (R = 0.283; p = 0.004) and AHI (R = 0.198; p = 0.048); in stepwise multiple regression analysis only BMI (p < 0.001) was a predictor of serum leptin values. One week after therapy, mean leptin serum level decreased to 11.0 ug/L and 6 months after it was 11.4 ug/L. (p = 0.56 and p = 0.387, respectively) Conclusion Baseline leptin serum levels positively correlate with BMI, fat distributioand OSA severity. BMI is the only predictor of basal leptin levels. Treatment with Autoadjusting-CPAP has a small effect on leptin levels. PMID:18828917

  16. Supraglottic airway devices in children

    PubMed Central

    Ramesh, S; Jayanthi, R

    2011-01-01

    Modern anaesthesia practice in children was made possible by the invention of the endotracheal tube (ET), which made lengthy and complex surgical procedures feasible without the disastrous complications of airway obstruction, aspiration of gastric contents or asphyxia. For decades, endotracheal intubation or bag-and-mask ventilation were the mainstays of airway management. In 1983, this changed with the invention of the laryngeal mask airway (LMA), the first supraglottic airway device that blended features of the facemask with those of the ET, providing ease of placement and hands-free maintenance along with a relatively secure airway. The invention and development of the LMA by Dr. Archie Brain has had a significant impact on the practice of anaesthesia, management of the difficult airway and cardiopulmonary resuscitation in children and neonates. This review article will be a brief about the clinical applications of supraglottic airways in children. PMID:22174464

  17. The Tulip GT® airway versus the facemask and Guedel airway: a randomised, controlled, cross-over study by Basic Life Support-trained airway providers in anaesthetised patients.

    PubMed

    Shaikh, A; Robinson, P N; Hasan, M

    2016-03-01

    We performed a randomised, controlled, cross-over study of lung ventilation by Basic Life Support-trained providers using either the Tulip GT® airway or a facemask with a Guedel airway in 60 anaesthetised patients. Successful ventilation was achieved if the provider produced an end-tidal CO2 > 3.5 kPa and a tidal volume > 250 ml in two of the first three breaths, within 60 sec and within two attempts. Fifty-seven (95%) providers achieved successful ventilation using the Tulip GT compared with 35 (58%) using the facemask (p < 0.0001). Comparing the Tulip GT and facemask, the mean (SD) end-tidal CO2 was 5.0 (0.7) kPa vs 2.5 (1.5) kPa, tidal volume was 494 (175) ml vs 286 (186) ml and peak inspiratory pressure was 18.3 (3.4) cmH2 O vs 13.6 (7) cmH2 O respectively (all p < 0.0001). Forty-seven (78%) users favoured the Tulip GT airway. These results are similar to a previous manikin study using the same protocol, suggesting a close correlation between human and manikin studies for this airway device. We conclude that the Tulip GT should be considered as an adjunct to airway management both within and outside hospitals when ventilation is being undertaken by Basic Life Support-trained airway providers.

  18. For Individuals with Obstructive Sleep Apnea, Institution of CPAP therapy is Associated with an Amelioration of Symptoms of Depression which is Sustained Long Term

    PubMed Central

    Schwartz, Daniel J.; Karatinos, Gillian

    2007-01-01

    Objective: To assess the sustainability of an improvement in symptoms of depression using CPAP therapy in patients with obstructive sleep apnea. Patients/Methods: Patients referred to our center for evaluation of obstructive sleep apnea who had a respiratory disturbance index (RDI) of ≥15 and who demonstrated a significant response to CPAP (50% or greater drop in RDI), were evaluated for symptoms of depression using the Beck Depression Inventory-Fast Screen for Medical Patients (BDI). These individuals were asked to complete the BDI assessment again after 4 to 6 weeks of treatment with CPAP (short-term follow-up), and then reassessed approximately one year later (long-term follow-up). Results: In this group of patients, the institution of CPAP therapy resulted in a significant decrease in those symptoms of depression assessed by the BDI at both the short-term and long-term follow-up periods. Conclusions: For patients with OSA who continue CPAP therapy, we noted a statistically significant, sustained improvement in those symptoms of depression measured by the BDI. Citation: Schwartz DJ; Karatinos G. For individuals with obstructive sleep apnea, institution of cpap therapy is associated with an amelioration of symptoms of depression which is sustained long term. J Clin Sleep Med 2007;3(6):631-635. PMID:17993046

  19. Effect of one week of CPAP treatment of obstructive sleep apnoea on 24-hour profiles of glucose, insulin and counter-regulatory hormones in type 2 diabetes.

    PubMed

    Mokhlesi, Babak; Grimaldi, Daniela; Beccuti, Guglielmo; Van Cauter, Eve

    2017-03-01

    Studies examining the impact of CPAP treatment on glycaemic control have yielded conflicting results, partly because of insufficient nightly CPAP use. We examined the 24-hour profiles of glucose, insulin and counter-regulatory hormones in 12 subjects with type 2 diabetes and OSA before and after 1 week of effective in-laboratory CPAP therapy over an entire 8-hour night thus ensuring optimal CPAP compliance. Blood samples were collected every 15 to 30 minutes for 24 hours under controlled conditions. The 24-hour mean glucose decreased from 153.2 ± 33.0 to 139.7 ± 24.2 mg/dL with CPAP (-13.5 ± 13.5 mg/dL; P = .005) without change in insulin levels. Morning fasting glucose levels decreased by 14.6 ± 3 mg/dL (P = .001) and the dawn phenomenon decreased by 7.8 ± 9.8 mg/dL (P = .019). CPAP treatment decreased norepinephrine levels while the 24-hour profiles of growth hormone and cortisol remained unchanged. In conclusion, 1 week of effective treatment of OSA over an entire 8-hour night results in a clinically significant improvement in glycaemic control via an amelioration of evening fasting glucose metabolism and a reduction in the dawn phenomenon, a late-night glucose increase that is not adequately treated by oral medications. Clinical Trials Information: ClinicalTrials.gov Identifier: NCT01136785.

  20. I-gel versus laryngeal mask airway-Proseal: Comparison of two supraglottic airway devices in short surgical procedures

    PubMed Central

    Jadhav, Poonam A; Dalvi, Naina P; Tendolkar, Bharati A

    2015-01-01

    Background and Aims: Supraglottic airway devices have been established in clinical anesthesia practice and have been previously shown to be safe and efficient. The objective of this prospective, randomized trial was to compare I-Gel with LMA-Proseal in anesthetized spontaneously breathing patients. Material and Methods: Sixty patients undergoing short surgical procedures were randomly assigned to I-gel (Group I) or LMA- Proseal (Group P). Anesthesia was induced with standard doses of propofol and the supraglottic airway device was inserted. We compared the ease and time required for insertion, airway sealing pressure and adverse events. Results: There were no significant differences in demographic and hemodynamic data. I-gel was significantly easier to insert than LMA-Proseal (P < 0.05) (Chi-square test). The mean time for insertion was more with Group P (41 + 09.41 secs) than with Group I (29.53 + 08.23 secs) (P < 0.05). Although the airway sealing pressure was significantly higher with Group P (25.73 + 02.21 cm of H2O), the airway sealing pressure of Group I (20.07 + 02.94 cm of H2O) was very well within normal limit (Student's t test). The success rate of first attempt insertion was more with Group I (P < 0.05). There was no evidence of airway trauma, regurgitation and aspiration. Sore throat was significantly more evident in Group P. Conclusion: I-Gel is a innovative supraglottic device with acceptable airway sealing pressure, easier to insert, less traumatic with lower incidence of sore throat. Hence I-Gel can be a good alternative to LMA-Proseal. PMID:25948905

  1. Air-Q intubating laryngeal airway: A study of the second generation supraglottic airway device

    PubMed Central

    Attarde, Viren Bhaskar; Kotekar, Nalini; Shetty, Sarika M

    2016-01-01

    Background and Aims: Air-Q intubating laryngeal mask airway (ILA) is used as a supraglottic airway device and as a conduit for endotracheal intubation. This study aims to assess the efficacy of the Air-Q ILA regarding ease of insertion, adequacy of ventilation, rate of successful intubation, haemodynamic response and airway morbidity. Methods: Sixty patients presenting for elective surgery at our Medical College Hospital were selected. Following adequate premedication, baseline vital parameters, pulse rate and blood pressure were recorded. Air-Q size 3.5 for patients 50-70 kg and size 4.5 for 70-100 kg was selected. After achieving adequate intubating conditions, Air-Q ILA was introduced. Confirming adequate ventilation, appropriate sized endotracheal tube was advanced through the Air-Q blindly to intubate the trachea. Placement of the endotracheal tube in trachea was confirmed. Results: Air-Q ILA was successfully inserted in 88.3% of patients in first attempt and 11.7% patients in second attempt. Ventilation was adequate in 100% of patients. Intubation was successful in 76.7% of patients with Air-Q ILA. 23.3% of patients were intubated by direct laryngoscopy following failure with two attempts using Air-Q ILA. Post-intubation the change in heart rate was statistically significant (P < 0.0001). 10% of patients were noted to have a sore throat and 5% of patients had mild airway trauma. Conclusion: Air-Q ILA is a reliable device as a supraglottic airway ensuring adequate ventilation as well as a conduit for endotracheal intubation. It benefits the patient by avoiding the stress of direct laryngoscopy and is also superior alternative device for use in a difficult airway. PMID:27212722

  2. Your Guide to Healthy Sleep

    MedlinePlus

    ... electronic media. Lack of sleep may have a direct effect on children’s health, behavior, and development. Chronic ... severe sleep apnea, you will need additional, more direct treatment approaches. Continuous positive airway pressure (CPAP) is ...

  3. Infant flow biphasic nasal continuous positive airway pressure (BP- NCPAP) vs. infant flow NCPAP for the facilitation of extubation in infants' ≤ 1,250 grams: a randomized controlled trial

    PubMed Central

    2012-01-01

    Abstract Background The use of mechanical ventilation is associated with lung injury in preterm infants and therefore the goal is to avoid or minimize its use. To date there is very little consensus on what is considered the "best non-invasive ventilation mode" to be used post-extubation. The objective of this study was to compare the effectiveness of biphasic nasal continuous positive airway pressure (BP-NCPAP) vs. NCPAP in facilitating sustained extubation in infants ≤ 1,250 grams. Methods We performed a randomized controlled trial of BP-NCPAP vs. NCPAP in infants ≤ 1,250 grams extubated for the first time following mechanical ventilation since birth. Infants were extubated using preset criteria or at the discretion of the attending neonatologist. The primary outcome was the incidence of sustained extubation for 7 days. Secondary outcomes included incidence of adverse events and short-term neonatal outcomes. Results Sixty-seven infants received BP-NCPAP and 69 NCPAP. Baseline characteristics were similar between groups. The trial was stopped early due to increased use of non-invasive ventilation from birth, falling short of our calculated sample size of 141 infants per group. The incidence of sustained extubation was not statistically different between the BP-NCPAP vs. NCPAP group (67% vs. 58%, P = 0.27). The incidence of adverse events and short-term neonatal outcomes were similar between the two groups (P > 0.05) except for retinopathy of prematurity which was noted to be higher (P = 0.02) in the BP-NCPAP group. Conclusions Biphasic NCPAP may be used to assist in weaning from mechanical ventilation. The effectiveness and safety of BP-NCPAP compared to NCPAP needs to be confirmed in a large multi-center trial as our study conclusions are limited by inadequate sample size. Clinical Trials Registration # NCT00308789 Source of support Grant # 06-06, Physicians Services Incorporated Foundation, Toronto, Canada. Summit technologies Inc. provided additional NCPAP

  4. Beneficial effects of severe sleep apnea therapy on nocturnal glucose control in persons with type 2 diabetes mellitus.

    PubMed

    Pallayova, Maria; Donic, Viliam; Tomori, Zoltan

    2008-07-01

    Given the consequences of sleep apnea and coexisting diabetes, satisfactory treatment of both diseases is required. Our results of continuous glucose monitoring in severe sleep apnea diabetic patients before and during continuous positive airway pressure/CPAP therapy showed significant reduction of nocturnal glucose variability and improved overnight glucose control on CPAP.

  5. Effect of aerosol propellants and surfactants on airway resistance

    PubMed Central

    Sterling, G. M.; Batten, J. C.

    1969-01-01

    The effects on the airways of inhalation of the vehicles used in two commercial pressurized bronchodilator aerosols were studied in 20 normal and seven asthmatic subjects. Changes in bronchial calibre due to bronchoconstriction were measured as changes in airway resistance using a constant volume whole body plethysmograph, and results were expressed as changes in the ratio Airway conductance/Thoracic gas volume (=specific airway conductance). The aerosols caused very slight bronchoconstriction in the normal subjects, with a mean decrease of 5·3% in specific airway conductance after inhalation of a spray containing sorbitol trioleate as a surface tension lowering agent, and of 9·7% after inhalation of a spray containing lecithin. This effect was prevented by prior inhalation of atropine methonitrate, and its mechanism was therefore probably a vagally mediated reflex. The bronchoconstriction was also reversed by the addition of isoprenaline to the aerosol. The asthmatic subjects showed larger mean reductions in specific airway conductance of 13% and 21% after sorbitol and lecithin respectively: the response was again prevented by atropine. We conclude that, although the aerosol vehicles cause slight bronchoconstriction, this is unlikely to be a clinical danger since it is insufficient to cause symptoms of wheezing, and is less than that caused by inhalation of a single cigarette. Moreover, the constriction is regularly converted to dilatation in both normal and asthmatic subjects by the addition of atropine or isoprenaline to the aerosol. PMID:5821624

  6. A mechanical design principle for tissue structure and function in the airway tree.

    PubMed

    LaPrad, Adam S; Lutchen, Kenneth R; Suki, Béla

    2013-01-01

    With every breath, the dynamically changing mechanical pressures must work in unison with the cells and soft tissue structures of the lung to permit air to efficiently traverse the airway tree and undergo gas exchange in the alveoli. The influence of mechanics on cell and tissue function is becoming apparent, raising the question: how does the airway tree co-exist within its mechanical environment to maintain normal cell function throughout its branching structure of diminishing dimensions? We introduce a new mechanical design principle for the conducting airway tree in which mechanotransduction at the level of cells is driven to orchestrate airway wall structural changes that can best maintain a preferred mechanical microenvironment. To support this principle, we report in vitro radius-transmural pressure relations for a range of airway radii obtained from healthy bovine lungs and model the data using a strain energy function together with a thick-walled cylinder description. From this framework, we estimate circumferential stresses and incremental Young's moduli throughout the airway tree. Our results indicate that the conducting airways consistently operate within a preferred mechanical homeostatic state, termed mechanical homeostasis, that is characterized by a narrow range of circumferential stresses and Young's moduli. This mechanical homeostatic state is maintained for all airways throughout the tree via airway wall dimensional and mechanical relationships. As a consequence, cells within the airway walls throughout the airway tree experience similar oscillatory strains during breathing that are much smaller than previously thought. Finally, we discuss the potential implications of how the maintenance of mechanical homeostasis, while facilitating healthy tissue-level alterations necessary for maturation, may lead to airway wall structural changes capable of chronic asthma.

  7. A dose-response curve for the negative bias pressure of an intrathoracic pressure regulator during CPR.

    PubMed

    Babbs, Charles F; Yannopoulos, Demetris

    2006-12-01

    An intrathoracic pressure regulator (ITPR) is a device that can be added to the external end of a tracheal tube to create controlled negative airway pressure between positive pressure ventilations. The resulting downward bias of the airway pressure baseline promotes increased venous return and enhanced circulation during CPR and also during hypovolemic shock. In the present study, we exercised a mathematical model of the human cardiopulmonary system, including airways, lungs, a four chambered heart, great vessels, peripheral vascular beds, and the biomechanics of chest compression and recoil, to determine the relationship between systemic perfusion pressure during CPR and the value of baseline negative airway pressure in an ITPR. Perfusion pressure increases approximately 50% as baseline airway pressure falls from zero to -10 cm H2O. Thereafter perfusion pressure plateaus. Negative bias pressures exceeding -10 cm H2O are not needed in ITPR-CPR.

  8. Operative endoscopy of the airway

    PubMed Central

    Walters, Dustin M.

    2016-01-01

    Airway endoscopy has long been an important and useful tool in the management of thoracic diseases. As thoracic specialists have gained experience with both flexible and rigid bronchoscopic techniques, the technology has continued to evolve so that bronchoscopy is currently the foundation for diagnosis and treatment of many thoracic ailments. Airway endoscopy plays a significant role in the biopsy of tumors within the airways, mediastinum, and lung parenchyma. Endoscopic methods have been developed to treat benign and malignant airway stenoses and tracheomalacia. And more recently, techniques have been conceived to treat end-stage emphysema and prolonged air leaks in select patients. This review describes the abundant uses of airway endoscopy, as well as technical considerations and limitations of the current technologies. PMID:26981263

  9. Global airway disease beyond allergy.

    PubMed

    Hellings, Peter W; Prokopakis, Emmanuel P

    2010-03-01

    Besides the anatomic continuity of the upper and lower airways, inflammation in one part of the airway influences the homeostasis of the other. The mechanisms underlying this interaction have been studied primarily in allergic disease, showing systemic immune activation, induction of inflammation at a distance, and a negative impact of nasal inflammation on bronchial homeostasis. In addition to allergy, other inflammatory conditions of the upper airways are associated with lower airway disease. Rhinosinusitis is frequently associated with asthma and chronic obstructive pulmonary disease. The impairment of purification, humidification, and warming up of the inspired air by the nose in rhinosinusitis may be responsible in part for bronchial pathology. The resolution of sinonasal inflammation via medical and/or surgical treatment is responsible for the beneficial effect of the treatment on bronchial disease. This article provides a comprehensive overview of the current knowledge of upper and lower airway communication beyond allergic disease.

  10. Recurrent airway obstruction: a review.

    PubMed

    Pirie, R S

    2014-05-01

    Recurrent airway obstruction is a widely recognised airway disorder, characterised by hypersensitivity-mediated neutrophilic airway inflammation and lower airway obstruction in a subpopulation of horses when exposed to suboptimal environments high in airborne organic dust. Over the past decade, numerous studies have further advanced our understanding of different aspects of the disease. These include clarification of the important inhaled airborne agents responsible for disease induction, improving our understanding of the underlying genetic basis of disease susceptibility and unveiling the fundamental immunological mechanisms leading to establishment of the classic disease phenotype. This review, as well as giving a clinical overview of recurrent airway obstruction, summarises much of the work in these areas that have culminated in a more thorough understanding of this debilitating disease.

  11. The airway microbiome and disease.

    PubMed

    Marsland, Benjamin J; Yadava, Koshika; Nicod, Laurent P

    2013-08-01

    Although traditionally thought to be sterile, accumulating evidence now supports the concept that our airways harbor a microbiome. Thus far, studies have focused upon characterizing the bacterial constituents of the airway microbiome in both healthy and diseased lungs, but what perhaps provides the greatest impetus for the exploration of the airway microbiome is that different bacterial phyla appear to dominate diseased as compared with healthy lungs. As yet, there is very limited evidence supporting a functional role for the airway microbiome, but continued research in this direction is likely to provide such evidence, particularly considering the progress that has been made in understanding host-microbe mutualism in the intestinal tract. In this review, we highlight the major advances that have been made discovering and describing the airway microbiome, discuss the experimental evidence that supports a functional role for the microbiome in health and disease, and propose how this emerging field is going to impact clinical practice.

  12. Using optical coherence tomography (OCT) imaging in the evaluation of airway dynamics (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Szabari, Margit V.; Kelly, Vanessa J.; Applegate, Matthew B.; Chee, Chunmin; Tan, Khay M.; Hariri, Lida P.; Harris, R. Scott; Winkler, Tilo; Suter, Melissa J.

    2016-03-01

    Asthma is a chronic disease resulting in periodic attacks of coughing and wheezing due to temporarily constricted and clogged airways. The pathophysiology of asthma and the process of airway narrowing are not completely understood. Appropriate in vivo imaging modality with sufficient spatial and temporal resolution to dynamically assess the behavior of airways is missing. Optical coherence tomography (OCT) enables real-time evaluation of the airways during dynamic and static breathing maneuvers. Our aim was to visualize the structure and function of airways in healthy and Methacholine (MCh) challenged lung. Sheep (n=3) were anesthetized, mechanically ventilated and imaged with OCT in 4 dependent and 4 independent airways both pre- and post-MCh administration. The OCT system employed a 2.4 Fr (0.8 mm diameter) catheter and acquired circumferential cross-sectional images in excess of 100 frames per second during dynamic tidal breathing, 20 second static breath-holds at end-inspiration and expiration pressure, and in a response to a single deep inhalation. Markedly different airway behavior was found in dependent versus non-dependent airway segments before and after MCh injection. OCT is a non-ionizing light-based imaging modality, which may provide valuable insight into the complex dynamic behavior of airway structure and function in the normal and asthmatic lung.

  13. Computational analysis of microbubble flows in bifurcating airways: role of gravity, inertia, and surface tension.

    PubMed

    Chen, Xiaodong; Zielinski, Rachel; Ghadiali, Samir N

    2014-10-01

    Although mechanical ventilation is a life-saving therapy for patients with severe lung disorders, the microbubble flows generated during ventilation generate hydrodynamic stresses, including pressure and shear stress gradients, which damage the pulmonary epithelium. In this study, we used computational fluid dynamics to investigate how gravity, inertia, and surface tension influence both microbubble flow patterns in bifurcating airways and the magnitude/distribution of hydrodynamic stresses on the airway wall. Direct interface tracking and finite element techniques were used to simulate bubble propagation in a two-dimensional (2D) liquid-filled bifurcating airway. Computational solutions of the full incompressible Navier-Stokes equation were used to investigate how inertia, gravity, and surface tension forces as characterized by the Reynolds (Re), Bond (Bo), and Capillary (Ca) numbers influence pressure and shear stress gradients at the airway wall. Gravity had a significant impact on flow patterns and hydrodynamic stress magnitudes where Bo > 1 led to dramatic changes in bubble shape and increased pressure and shear stress gradients in the upper daughter airway. Interestingly, increased pressure gradients near the bifurcation point (i.e., carina) were only elevated during asymmetric bubble splitting. Although changes in pressure gradient magnitudes were generally more sensitive to Ca, under large Re conditions, both Re and Ca significantly altered the pressure gradient magnitude. We conclude that inertia, gravity, and surface tension can all have a significant impact on microbubble flow patterns and hydrodynamic stresses in bifurcating airways.

  14. Estimating the diameter of airways susceptible for collapse using crackle sound.

    PubMed

    Majumdar, Arnab; Hantos, Zoltán; Tolnai, József; Parameswaran, Harikrishnan; Tepper, Robert; Suki, Béla

    2009-11-01

    Airways that collapse during deflation generate a crackle sound when they reopen during subsequent reinflation. Since each crackle is associated with the reopening of a collapsed airway, the likelihood of an airway to be a crackle source is identical to its vulnerability to collapse. To investigate this vulnerability of airways to collapse, crackles were recorded during the first inflation of six excised rabbit lungs from the collapsed state, and subsequent reinflations from 5, 2, 1, and 0 cmH(2)O end-expiratory pressure levels. We derived a relationship between the amplitude of a crackle sound at the trachea and the generation number (n) of the source airway where the crackle was generated. Using an asymmetrical tree model of the rabbit airways with elastic walls, airway vulnerability to collapse was also determined in terms of airway diameter D. During the reinflation from end-expiratory pressure = 0 cmH(2)O, the most vulnerable airways were estimated to be centered at n = 12 with a peak. Vulnerability in terms of D ranged between 0.1 and 1.3 mm, with a peak at 0.3 mm. During the inflation from the collapsed state, however, vulnerability was much less localized to a particular n or D, with maximum values of n = 8 and D = 0.75 mm. Numerical simulations using a tree model that incorporates airway opening and closing support these conclusions. Thus our results indicate that there are airways of a given range of diameters that can become unstable during deflation and vulnerable to collapse and subsequent injury.

  15. [Acute pulmonary edema secondary to acute upper airway obstruction].

    PubMed

    Sánchez-Ortega, J L; Carpintero-Moreno, F; Olivares-López, A; Borrás-Rubio, E; Alvarez-López, M J; García-Izquierdo, A

    1992-01-01

    We report a 72 years old woman with mild arterial hypertension and no other pathological history who presented an acute pulmonary edema due to acute obstruction of the upper airway secondary to vocal chord paralysis developing during the immediate postoperative phase of thyroidectomy. The acute pulmonary edema resolved after application of tracheal reintubation, mechanical ventilation controlled with end expiratory positive pressure, diuretics, morphine, and liquid restriction. We discuss the possible etiopathogenic possibilities of this infrequent clinical picture and we suggest that all patients who suffered and acute obstruction of the upper airways require a careful clinical surveillance in order to prevent the development of the pulmonary syndrome.

  16. Negative-Pressure Pulmonary Edema.

    PubMed

    Bhattacharya, Mallar; Kallet, Richard H; Ware, Lorraine B; Matthay, Michael A

    2016-10-01

    Negative-pressure pulmonary edema (NPPE) or postobstructive pulmonary edema is a well-described cause of acute respiratory failure that occurs after intense inspiratory effort against an obstructed airway, usually from upper airway infection, tumor, or laryngospasm. Patients with NPPE generate very negative airway pressures, which augment transvascular fluid filtration and precipitate interstitial and alveolar edema. Pulmonary edema fluid collected from most patients with NPPE has a low protein concentration, suggesting hydrostatic forces as the primary mechanism for the pathogenesis of NPPE. Supportive care should be directed at relieving the upper airway obstruction by endotracheal intubation or cricothyroidotomy, institution of lung-protective positive-pressure ventilation, and diuresis unless the patient is in shock. Resolution of the pulmonary edema is usually rapid, in part because alveolar fluid clearance mechanisms are intact. In this review, we discuss the clinical presentation, pathophysiology, and management of negative-pressure or postobstructive pulmonary edema.

  17. Jet ventilation for surgical interventions in the upper airway.

    PubMed

    Biro, Peter

    2010-09-01

    The clinical applications of jet ventilation (JV) in ear, nose, and throat surgery can be best understood by the characteristics that distinguish this form of ventilation from conventional positive pressure ventilation. By definition, JV is based on the application of gas portions under high pressure through an unblocked catheter into the airway, which is open to the ambient air. Beneficial opportunities arise in JV, which otherwise are not available in regular ventilation.

  18. Putting the Squeeze on Airway Epithelia

    PubMed Central

    Park, Jin-Ah; Fredberg, Jeffrey J.

    2015-01-01

    Asthma is characterized by chronic inflammation, airway hyperresponsiveness, and progressive airway remodeling. The airway epithelium is known to play a critical role in the initiation and perpetuation of these processes. Here, we review how excessive epithelial stress generated by bronchoconstriction is sufficient to induce airway remodeling, even in the absence of inflammatory cells. PMID:26136543

  19. The GABAA agonist muscimol attenuates induced airway constriction in guinea pigs in vivo.

    PubMed

    Gleason, Neil R; Gallos, George; Zhang, Yi; Emala, Charles W

    2009-04-01

    GABA(A) channels are ubiquitously expressed on neuronal cells and act via an inward chloride current to hyperpolarize the cell membrane of mature neurons. Expression and function of GABA(A) channels on airway smooth muscle cells has been demonstrated in vitro. Airway smooth muscle cell membrane hyperpolarization contributes to relaxation. We hypothesized that muscimol, a selective GABA(A) agonist, could act on endogenous GABA(A) channels expressed on airway smooth muscle to attenuate induced increases in airway pressures in anesthetized guinea pigs in vivo. In an effort to localize muscimol's effect to GABA(A) channels expressed on airway smooth muscle, we pretreated guinea pigs with a selective GABA(A) antagonist (gabazine) or eliminated lung neural control from central parasympathetic, sympathetic, and nonadrenergic, noncholinergic (NANC) nerves before muscimol treatment. Pretreatment with intravenous muscimol alone attenuated intravenous histamine-, intravenous acetylcholine-, or vagal nerve-stimulated increases in peak pulmonary inflation pressure. Pretreatment with the GABA(A) antagonist gabazine blocked muscimol's effect. After the elimination of neural input to airway tone by central parasympathetic nerves, peripheral sympathetic nerves, and NANC nerves, intravenous muscimol retained its ability to block intravenous acetylcholine-induced increases in peak pulmonary inflation pressures. These findings demonstrate that the GABA(A) agonist muscimol acting specifically via GABA(A) channel activation attenuates airway constriction independently of neural contributions. These findings suggest that therapeutics directed at the airway smooth muscle GABA(A) channel may be a novel therapy for airway constriction following airway irritation and possibly more broadly in diseases such as asthma and chronic obstructive pulmonary disease.

  20. [Experiences with therapy of pediatric sleep apnea syndrome and obstructive nasopharyngeal respiratory pattern with nasal BIPAP and CPAP therapy].

    PubMed

    Zwacka, G; Scholle, S

    1995-03-01

    Sleep-apnea in childhood shows a frequency similar to adults but it is caused by many other reasons. Therapeutic effects of nasal CPAP and BIPAP can replace surgical ENT-Therapy in large extent mainly in ages at 2-5 years. But also in older children is it possible to treat obstructive sleep apnea and hypoventilation neuromuscular diseases by BIPAP. Examples for treatment of children by BIPAP who are two years old were given. Other demonstrated cases cover children with stridor congenitus, obstructive sleep apnea, hypoventilation, adenoidal breathing disturbances with primary surgical treated tonsillar hyperplasia and one case of thoracal postobstructive malformation with therapeutic BIPAP options.

  1. Computational Flow Modeling of Human Upper Airway Breathing

    NASA Astrophysics Data System (ADS)

    Mylavarapu, Goutham

    Computational modeling of biological systems have gained a lot of interest in biomedical research, in the recent past. This thesis focuses on the application of computational simulations to study airflow dynamics in human upper respiratory tract. With advancements in medical imaging, patient specific geometries of anatomically accurate respiratory tracts can now be reconstructed from Magnetic Resonance Images (MRI) or Computed Tomography (CT) scans, with better and accurate details than traditional cadaver cast models. Computational studies using these individualized geometrical models have advantages of non-invasiveness, ease, minimum patient interaction, improved accuracy over experimental and clinical studies. Numerical simulations can provide detailed flow fields including velocities, flow rates, airway wall pressure, shear stresses, turbulence in an airway. Interpretation of these physical quantities will enable to develop efficient treatment procedures, medical devices, targeted drug delivery etc. The hypothesis for this research is that computational modeling can predict the outcomes of a surgical intervention or a treatment plan prior to its application and will guide the physician in providing better treatment to the patients. In the current work, three different computational approaches Computational Fluid Dynamics (CFD), Flow-Structure Interaction (FSI) and Particle Flow simulations were used to investigate flow in airway geometries. CFD approach assumes airway wall as rigid, and relatively easy to simulate, compared to the more challenging FSI approach, where interactions of airway wall deformations with flow are also accounted. The CFD methodology using different turbulence models is validated against experimental measurements in an airway phantom. Two case-studies using CFD, to quantify a pre and post-operative airway and another, to perform virtual surgery to determine the best possible surgery in a constricted airway is demonstrated. The unsteady

  2. Airway complications after lung transplantation.

    PubMed

    Machuzak, Michael; Santacruz, Jose F; Gildea, Thomas; Murthy, Sudish C

    2015-01-01

    Airway complications after lung transplantation present a formidable challenge to the lung transplant team, ranging from mere unusual images to fatal events. The exact incidence of complications is wide-ranging depending on the type of event, and there is still evolution of a universal characterization of the airway findings. Management is also wide-ranging. Simple observation or simple balloon bronchoplasty is sufficient in many cases, but vigilance following more severe necrosis is required for late development of both anastomotic and nonanastomotic airway strictures. Furthermore, the impact of coexisting infection, rejection, and medical disease associated with high-level immunosuppression further complicates care.

  3. Gene Delivery to the Airway

    PubMed Central

    Keiser, Nicholas W.; Engelhardt, John F.

    2013-01-01

    This unit describes generation of and gene transfer to several commonly used airway models. Isolation and transduction of primary airway epithelial cells are first described. Next, the preparation of polarized airway epithelial monolayers is outlined. Transduction of these polarized cells is also described. Methods are presented for generation of tracheal xenografts as well as both ex vivo and in vivo gene transfer to these xenografts. Finally, a method for in vivo gene delivery to the lungs of rodents is included. Methods for evaluating transgene expression are given in the support protocols. PMID:23853081

  4. United airway disease: current perspectives

    PubMed Central

    Giavina-Bianchi, Pedro; Aun, Marcelo Vivolo; Takejima, Priscila; Kalil, Jorge; Agondi, Rosana Câmara

    2016-01-01

    Upper and lower airways are considered a unified morphological and functional unit, and the connection existing between them has been observed for many years, both in health and in disease. There is strong epidemiologic, pathophysiologic, and clinical evidence supporting an integrated view of rhinitis and asthma: united airway disease in the present review. The term “united airway disease” is opportune, because rhinitis and asthma are chronic inflammatory diseases of the upper and lower airways, which can be induced by allergic or nonallergic reproducible mechanisms, and present several phenotypes. Management of rhinitis and asthma must be jointly carried out, leading to better control of both diseases, and the lessons of the Allergic Rhinitis and Its Impact on Asthma initiative cannot be forgotten. PMID:27257389

  5. Apoptosis and the Airway Epithelium

    PubMed Central

    White, Steven R.

    2011-01-01

    The airway epithelium functions as a barrier and front line of host defense in the lung. Apoptosis or programmed cell death can be elicited in the epithelium as a response to viral infection, exposure to allergen or to environmental toxins, or to drugs. While apoptosis can be induced via activation of death receptors on the cell surface or by disruption of mitochondrial polarity, epithelial cells compared to inflammatory cells are more resistant to apoptotic stimuli. This paper focuses on the response of airway epithelium to apoptosis in the normal state, apoptosis as a potential regulator of the number and types of epithelial cells in the airway, and the contribution of epithelial cell apoptosis in important airways diseases. PMID:22203854

  6. Extraglottic airway devices: A review

    PubMed Central

    Ramaiah, Ramesh; Das, Debasmita; Bhananker, Sanjay M; Joffe, Aaron M

    2014-01-01

    Extraglottic airway devices (EAD) have become an integral part of anesthetic care since their introduction into clinical practice 25 years ago and have been used safely hundreds of millions of times, worldwide. They are an important first option for difficult ventilation during both in-hospital and out-of-hospital difficult airway management and can be utilized as a conduit for tracheal intubation either blindly or assisted by another technology (fiberoptic endoscopy, lightwand). Thus, the EAD may be the most versatile single airway technique in the airway management toolbox. However, despite their utility, knowledge regarding specific devices and the supporting data for their use is of paramount importance to patient's safety. In this review, number of commercially available EADs are discussed and the reported benefits and potential pitfalls are highlighted. PMID:24741502

  7. A new removable airway stent

    PubMed Central

    Amundsen, Tore; Sørhaug, Sveinung; Leira, Håkon Olav; Tyvold, Stig Sverre; Langø, Thomas; Hammer, Tommy; Manstad-Hulaas, Frode; Mattsson, Erney

    2016-01-01

    Background Malignant airway obstruction is a feared complication and will most probably occur more frequently in the future because of increasing cancer incidence and increased life expectancy in cancer patients. Minimal invasive treatment using airway stents represents a meaningful and life-saving palliation. We present a new removable airway stent for improved individualised treatment. Methods To our knowledge, the new airway stent is the world's first knitted and uncovered self-expanding metal stent, which can unravel and be completely removed. In an in vivo model using two anaesthetised and spontaneously breathing pigs, we deployed and subsequently removed the stents by unravelling the device. The procedures were executed by flexible bronchoscopy in an acute and a chronic setting – a ‘proof-of-principle’ study. Results The new stent was easily and accurately deployed in the central airways, and it remained fixed in its original position. It was easy to unravel and completely remove from the airways without clinically significant complications. During the presence of the stent in the chronic study, granulation tissue was induced. This tissue disappeared spontaneously with the removal. Conclusions The new removable stent functioned according to its purpose and unravelled easily, and it was completely removed without significant technical or medical complications. Induced granulation tissue disappeared spontaneously. Further studies on animals and humans are needed to define its optimal indications and future use. PMID:27608269

  8. Functional contribution of mandibular advancement to awake upper airway patency in obstructive sleep apnea.

    PubMed

    Tsuiki, Satoru; Ryan, C Frank; Lowe, Alan A; Inoue, Yuichi

    2007-12-01

    In the narrowed upper airway of patients with obstructive sleep apnea (OSA), a neuromuscular compensatory mechanism augments the activity of the upper airway dilator muscles in defense of upper airway patency, particularly during inspiration. We hypothesized that mechanical enlargement of the upper airway by a mandibular advancement oral appliance would permit a reduction in this neuromuscular compensation during wakefulness. To test this hypothesis, we focused on changes in the cross-sectional (CS) area of the upper airway before and after emplacement of a ventrally titrated oral appliance in 12 awake OSA patients. The CS areas at the end of tidal expiration (CS area-EET) and at the nadir of intraluminal pressure during inspiration (CS area-IN) were obtained using videoendoscopy. The median apnea-hypopnea index decreased with mandibular advancement. Before mandibular advancement, there was no difference between CS area-EET and CS area-IN in the velopharynx, oropharynx, and hypopharynx. This indicates that upper airway dilator muscle activity increased during inspiration to counteract the intraluminal negative pressure of the upper airway. After mandibular advancement, CS area-EET increased in the velopharynx, oropharynx, and hypopharynx, but CS area-IN was unchanged at any level and was less than CS area-EET in the velopharynx and oropharynx. These findings suggest that mandibular advancement enlarges the upper airway and may reduce upper airway dilator muscle activity during inspiration. We conclude that oral appliances act to return the upper airway towards a normal configuration and pattern of muscle function in OSA patients.

  9. Numerical Simulation for Mechanism of Airway Narrowing in Asthma

    NASA Astrophysics Data System (ADS)

    Bando, Kiyoshi; Yamashita, Daisuke; Ohba, Kenkichi

    A calculation model is proposed to examine the generation mechanism of the numerous lobes on the inner-wall of the airway in asthmatic patients and to clarify luminal occlusion of the airway inducing breathing difficulties. The basement membrane in the airway wall is modeled as a two-dimensional thin-walled shell having inertia force due to the mass, and the smooth muscle contraction effect is replaced by uniform transmural pressure applied to the basement membrane. A dynamic explicit finite element method is used as a numerical simulation method. To examine the validity of the present model, simulation of an asthma attack is performed. The number of lobes generated in the basement membrane increases when transmural pressure is applied in a shorter time period. When the remodeling of the basement membrane occurs characterized by thickening and hardening, it is demonstrated that the number of lobes decreases and the narrowing of the airway lumen becomes severe. Comparison of the results calculated by the present model with those measured for animal experiments of asthma will be possible.

  10. Dynamic Visco-elastic Buckling Analysis for Airway Model

    NASA Astrophysics Data System (ADS)

    Bando, Kiyoshi; Ohba, Kenkichi; Yamanoi, Yuta

    In order to clarify the mechanism by which the lung airway narrows during an asthma attack, dynamic buckling analysis of the wall was conducted. The wall was modeled using a visco-elastic thin-walled circular cylinder of the Voigt model for the planestress state. A governing equation for dynamic buckling was derived, and in the equation, the contraction of smooth muscle was replaced by uniform inward transmural pressure. The non-dimensional parameters for the buckling wave number n were nondimensional retardation time τ, non-dimensional increasing velocity of inward transmural pressure β, thickness radius ratio α2, radius length ratio η, density ratio ζ, and Poisson's ratio ν. The validity of the theoretical model was confirmed by comparing the calculated wave number with that obtained from the experiment, in which a silicone rubber tube blended with silicone potting gel was used as the in vitro airway model. In addition, the wave number n increased with β. It was necessary to consider the damping effect of the tube model or the airway wall, and n increased by 1.5 to 2 due to the additional mass effect of surrounding tissues of the basement membrane in the airway wall.

  11. On locating the obstruction in the human upper airway

    NASA Astrophysics Data System (ADS)

    Wang, Yong; Elghobashi, S.

    2013-11-01

    The fluid dynamical properties of the air flow in the human upper airway (UA) are not fully understood at present due to the three-dimensional, patient-specific complex geometry of the airway, flow transition from laminar to turbulent and flow-structure interaction during the breathing cycle. One of the major challenges to surgeons is determining the location of the UA obstruction before performing corrective surgeries. It is quite difficult at present to experimentally measure the instantaneous velocity and pressure at specific points in the human airway. On the other hand, direct numerical simulation (DNS) can predict all the flow properties and resolve all its relevant length- and time-scales. We developed a DNS solver with lattice Boltzmann method (LBM), and used it to investigate the flow in two patient-specific UAs reconstructed from CT scan data. Inspiration and expiration flows through these two airways are studied and compared. Pressure gradient-time signals at different locations in the UAs are used to determine the location of the obstruction. This work was supported by the National Heart, Lung, and Blood Institute (NHLBI) of the National Institutes of Health (NIH).

  12. Human airway ciliary dynamics

    PubMed Central

    Thompson, Kristin; Knowles, Michael R.; Davis, C. William

    2013-01-01

    Airway cilia depend on precise changes in shape to transport the mucus gel overlying mucosal surfaces. The ciliary motion can be recorded in several planes using video microscopy. However, cilia are densely packed, and automated computerized systems are not available to convert these ciliary shape changes into forms that are useful for testing theoretical models of ciliary function. We developed a system for converting planar ciliary motions recorded by video microscopy into an empirical quantitative model, which is easy to use in validating mathematical models, or in examining ciliary function, e.g., in primary ciliary dyskinesia (PCD). The system we developed allows the manipulation of a model cilium superimposed over a video of beating cilia. Data were analyzed to determine shear angles and velocity vectors of points along the cilium. Extracted waveforms were used to construct a composite waveform, which could be used as a standard. Variability was measured as the mean difference in position of points on individual waveforms and the standard. The shapes analyzed were the end-recovery, end-effective, and fastest moving effective and recovery with mean (± SE) differences of 0.31(0.04), 0.25(0.06), 0.50(0.12), 0.50(0.10), μm, respectively. In contrast, the same measures for three different PCD waveforms had values far outside this range. PMID:23144323

  13. Airway Hydration and COPD

    PubMed Central

    Ghosh, Arunava; Boucher, R.C.; Tarran, Robert

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is one of the prevalent causes of worldwide mortality and encompasses two major clinical phenotypes, i.e., chronic bronchitis (CB) and emphysema. The most common cause of COPD is chronic tobacco inhalation. Research focused on the chronic bronchitic phenotype of COPD has identified several pathological processes that drive disease initiation and progression. For example, the lung’s mucociliary clearance (MCC) system performs the critical task of clearing inhaled pathogens and toxic materials from the lung. MCC efficiency is dependent on: (i) the ability of apical plasma membrane ion channels such as the cystic fibrosis transmembrane conductance regulator (CFTR) and the epithelial Na+ channel (ENaC) to maintain airway hydration; (ii) ciliary beating; and, (iii) appropriate rates of mucin secretion. Each of these components is impaired in CB and likely contributes to the mucus stasis/accumulation seen in CB patients. This review highlights the cellular components responsible for maintaining MCC and how this process is disrupted following tobacco exposure and with CB. We shall also discuss existing therapeutic strategies for the treatment of chronic bronchitis and how components of the MCC can be used as biomarkers for the evaluation of tobacco or tobacco-like-product exposure. PMID:26068443

  14. Oxygenation, Ventilation, and Airway Management in Out-of-Hospital Cardiac Arrest: A Review

    PubMed Central

    Henlin, Tomas; Michalek, Pavel; Tyll, Tomas; Hinds, John D.; Dobias, Milos

    2014-01-01

    Recently published evidence has challenged some protocols related to oxygenation, ventilation, and airway management for out-of-hospital cardiac arrest. Interrupting chest compressions to attempt airway intervention in the early stages of OHCA in adults may worsen patient outcomes. The change of BLS algorithms from ABC to CAB was recommended by the AHA in 2010. Passive insufflation of oxygen into a patent airway may provide oxygenation in the early stages of cardiac arrest. Various alternatives to tracheal intubation or bag-mask ventilation have been trialled for prehospital airway management. Simple methods of airway management are associated with similar outcomes as tracheal intubation in patients with OHCA. The insertion of a laryngeal mask airway is probably associated with worse neurologically intact survival rates in comparison with other methods of airway management. Hyperoxemia following OHCA may have a deleterious effect on the neurological recovery of patients. Extracorporeal oxygenation techniques have been utilized by specialized centers, though their use in OHCA remains controversial. Chest hyperinflation and positive airway pressure may have a negative impact on hemodynamics during resuscitation and should be avoided. Dyscarbia in the postresuscitation period is relatively common, mainly in association with therapeutic hypothermia, and may worsen neurological outcome. PMID:24724081

  15. Kinematic MRI study of upper-airway biomechanics using electrical muscle stimulation

    NASA Astrophysics Data System (ADS)

    Brennick, Michael J.; Margulies, Susan S.; Ford, John C.; Gefter, Warren B.; Pack, Allan I.

    1997-05-01

    We have developed a new and powerful method to study the movement and function of upper airway muscles. Our method is to use direct electrical stimulation of individual upper airway muscles, while performing state of the art high resolution magnetic resonance imaging (MRI). We have adapted a paralyzed isolated UA cat model so that positive or negative static pressure in the UA can be controlled at specific levels while electrical muscle stimulation is applied during MRI. With these techniques we can assess the effect of muscle stimulation on airway cross-sectional area compliance and soft tissue motion. We are reporting the preliminary results and MRI techniques which have enabled us to examine changes in airway dimensions which result form electrical stimulation of specific upper airway dilator muscles. The results of this study will be relevant to the development of new clinical treatments for obstructive sleep apnea by providing new information as to exactly how upper airway muscles function to dilate the upper airway and the strength of stimulation required to prevent the airway obstruction when overall muscle tone may not be sufficient to maintain regular breathing.

  16. Effects of hypercapnia and inspiratory flow-resistive loading on respiratory activity in chronic airways obstruction.

    PubMed Central

    Altose, M D; McCauley, W C; Kelsen, S G; Cherniack, N S

    1977-01-01

    The respiratory responses to hypercapnia alone and to hypercapnia and flow-resistive loading during inspiration were studied in normal individuals and in eucapnic and hypercapnic patients with chronic airways obstruction. Responses were assessed in terms of minute ventilation and occlusion pressure (mouth pressure during airway occlusion 100 ms after the onset of inspiration). Ventilatory responses to CO2 (deltaV/deltaPCO2) were distinctly subnormal in both groups of patients with airways obstruction. The two groups of patients, however, showed different occlusion pressure responses to CO2 (deltaP100/deltaPCO2): deltaP100/deltaPCO2 was normal in the eucapnic patients but subnormal in the hypercapnic patients. Flow-resistive loading during inspiration reduced deltaV/deltaPCO2 both in normal subjects and in patients with airways obstruction. The occlusion pressure response to CO2 increased in normal subjects during flow-resistive loading but remained unchanged in both groups of patients with chronic airways obstruction. These results indicate that while chemosensitivity as determined by deltaP100/deltaPCO2 is impaired only in hypercapnic patients with chronic airways obstruction, an acute increase in flow resistance elicits a subnormal increase in respiratory efferent activity in both eucapnic and hypercapnic patients. PMID:838862

  17. Efficacy of Surgical Airway Plasty for Benign Airway Stenosis

    PubMed Central

    Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Inoue, Hidetoshi; Yamamoto, Ryoji

    2015-01-01

    Background: Long-term patency is required during treatment for benign airway stenosis. This study investigated the effectiveness of surgical airway plasty for benign airway stenosis. Methods: Clinical courses of 20 patients, who were treated with surgical plasty for their benign airway stenosis, were retrospectively investigated. Results: Causes of stenosis were tracheobronchial tuberculosis in 12 patients, post-intubation stenosis in five patients, malacia in two patients, and others in one patient. 28 interventional pulmonology procedures and 20 surgical plasty were performed. Five patients with post-intubation stenosis and four patients with tuberculous stenosis were treated with tracheoplasty. Eight patients with tuberculous stenosis were treated with bronchoplasty, and two patients with malacia were treated with stabilization of the membranous portion. Anastomotic stenosis was observed in four patients, and one to four additional treatments were required. Performance status, Hugh–Jones classification, and ventilatory functions were improved after surgical plasty. Outcomes were fair in patients with tuberculous stenosis and malacia. However, efficacy of surgical plasty for post-intubation stenosis was not observed. Conclusion: Surgical airway plasty may be an acceptable treatment for tuberculous stenosis. Patients with malacia recover well after surgical plasty. There may be untreated patients with malacia who have the potential to benefit from surgical plasty. PMID:26567879

  18. Airflow behavior changes in upper airway caused by different head and neck positions: Comparison by computational fluid dynamics.

    PubMed

    Wei, Wei; Huang, Shi-Wei; Chen, Lian-Hua; Qi, Yang; Qiu, Yi-Min; Li, Shi-Tong

    2017-02-08

    The feasibility of computational fluid dynamics (CFD) to evaluate airflow characteristics in different head and neck positions has not been established. This study compared the changes in volume and airflow behavior of the upper airway by CFD simulation to predict the influence of anatomical and physiological airway changes due to different head-neck positions on mechanical ventilation. One awake volunteer with no risk of difficult airway underwent computed tomography in neutral position, extension position (both head and neck extended), and sniffing position (head extended and neck flexed). Three-dimensional airway models of the upper airway were reconstructed. The total volume (V) and narrowest area (Amin) of the airway models were measured. CFD simulation with an Spalart-Allmaras model was performed to characterize airflow behavior in neutral, extension, and sniffing positions of closed-mouth and open-mouth ventilation. The comparison result for V was neutral pressure drop and velocity increasing were more obvious in neutral than sniffing or extension position at the same airflow rate. In sniffing position, pressure differences decreased and velocity remained almost constant. Recirculation airflow was generated near the subglottic region in neutral and extension positions. Sniffing position improves airway patency by increasing airway volume and decreasing airway resistance, suggesting that sniffing position may be the optimal choice for mask ventilation.

  19. Comparison of streamlined liner of the pharynx airway (SLIPA ™) and laryngeal mask airway: a systematic review and meta-analysis.

    PubMed

    Choi, G J; Kang, H; Baek, C W; Jung, Y H; Woo, Y C; Kim, S H; Kim, J G

    2015-05-01

    We performed a systematic review to compare the efficacy and safety of the streamlined liner of the pharynx airway and laryngeal mask airway used in adults during general anaesthesia. We included 14 studies with studies with 1273 patients in total. There was no evidence of a difference between the two devices in insertion success rate on the first attempt (13 studies, 1143 patients), insertion time (seven studies, 576 patients), ease of insertion (five studies, 466 patients), oropharyngeal leak pressure (eight studies, 771 patients) and the quality of the fibreoptic view of the larynx through the device (three studies, 281 patients). The relative risk (95% CI) of bloodstaining of the device (nine studies, 859 patients) was 2.09 (1.46-3.00) for the streamlined liner of the pharynx airway compared with the laryngeal mask airway. Other adverse events were comparable. Subgroup analysis suggested that the insertion by novice users might be faster and more successful with the streamlined liner of the pharynx airway than the laryngeal mask airway; however, this was from only two studies and 186 patients. The method of size selection of the streamlined liner of the pharynx airway device might also affect the speed of insertion: choosing according to the width of the patient's thyroid cartilage, rather than height, may produce better results.

  20. Airway management using a supraglottic airway device without endotracheal intubation for positive ventilation of anaesthetized rats.

    PubMed

    Cheong, S H; Lee, J H; Kim, M H; Cho, K R; Lim, S H; Lee, K M; Park, M Y; Yang, Y I; Kim, D K; Choi, C S

    2013-04-01

    Endotracheal intubation is often necessary for positive pressure ventilation of rats during open thoracic surgery. Since endotracheal intubation in rats is technically difficult and is associated with numerous complications, many techniques using various devices have been described in the scientific literature. In this study, we compared the effectiveness of airway management of a home-made supraglottic airway device (SAD), which is cheap to fabricate and easy to place with that of an endotracheal intubation tube in enflurane-anaesthetized rats. Twenty male Sprague-Dawley rats (200-300 g) were randomly assigned to two equal groups for positive pressure mechanical ventilation using either the SAD or an endotracheal intubation tube. The carotid artery of each rat was cannulated for continuous blood pressure measurements and obtaining blood samples for determination of oxygen tension, carbon dioxide tension, and blood acidity before, during and after SAD placement or endotracheal intubation. Proper placement of the SAD was confirmed by observing chest wall movements that coincided with the operation of the mechanical ventilator. No complications and adverse events were encountered in the rats in which the SAD was placed, during SAD placement and immediate removal, during their mechanical ventilation through the SAD, and one week after SAD removal. From the results of blood gas analyses, we conclude that anaesthetized rats can be successfully ventilated using an SAD for open thoracic surgery.

  1. Phases-of-illness paradigm: better communication, better outcomes

    DTIC Science & Technology

    2011-11-28

    as making an accurate diagnosis , optimizing a treatment strategy, providing valuable family support, or attending another patient. Application A...airway pressure; CBC, complete blood count; CIN, contrast-induced nephropathy ; CPAP, continuous positive airway pressure; CRP, C-reactive protein; DSH

  2. The Airway Microbiome at Birth

    PubMed Central

    Lal, Charitharth Vivek; Travers, Colm; Aghai, Zubair H.; Eipers, Peter; Jilling, Tamas; Halloran, Brian; Carlo, Waldemar A.; Keeley, Jordan; Rezonzew, Gabriel; Kumar, Ranjit; Morrow, Casey; Bhandari, Vineet; Ambalavanan, Namasivayam

    2016-01-01

    Alterations of pulmonary microbiome have been recognized in multiple respiratory disorders. It is critically important to ascertain if an airway microbiome exists at birth and if so, whether it is associated with subsequent lung disease. We found an established diverse and similar airway microbiome at birth in both preterm and term infants, which was more diverse and different from that of older preterm infants with established chronic lung disease (bronchopulmonary dysplasia). Consistent temporal dysbiotic changes in the airway microbiome were seen from birth to the development of bronchopulmonary dysplasia in extremely preterm infants. Genus Lactobacillus was decreased at birth in infants with chorioamnionitis and in preterm infants who subsequently went on to develop lung disease. Our results, taken together with previous literature indicating a placental and amniotic fluid microbiome, suggest fetal acquisition of an airway microbiome. We speculate that the early airway microbiome may prime the developing pulmonary immune system, and dysbiosis in its development may set the stage for subsequent lung disease. PMID:27488092

  3. Numerical simulation of soft palate movement and airflow in human upper airway by fluid-structure interaction method

    NASA Astrophysics Data System (ADS)

    Sun, Xiuzhen; Yu, Chi; Wang, Yuefang; Liu, Yingxi

    2007-08-01

    In this paper, the authors present airflow field characteristics of human upper airway and soft palate movement attitude during breathing. On the basis of the data taken from the spiral computerized tomography images of a healthy person and a patient with Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS), three-dimensional models of upper airway cavity and soft palate are reconstructed by the method of surface rendering. Numerical simulation is performed for airflow in the upper airway and displacement of soft palate by fluid-structure interaction analysis. The reconstructed three-dimensional models precisely preserve the original configuration of upper airways and soft palate. The results of the pressure and velocity distributions in the airflow field are quantitatively determined, and the displacement of soft palate is presented. Pressure gradients of airway are lower for the healthy person and the airflow distribution is quite uniform in the case of free breathing. However, the OSAHS patient remarkably escalates both the pressure and velocity in the upper airway, and causes higher displacement of the soft palate. The present study is useful in revealing pathogenesis and quantitative mutual relationship between configuration and function of the upper airway as well as in diagnosing diseases related to anatomical structure and function of the upper airway.

  4. Cystic Fibrosis Transmembrane Conductance Regulator in Sarcoplasmic Reticulum of Airway Smooth Muscle. Implications for Airway Contractility

    PubMed Central

    Cook, Daniel P.; Rector, Michael V.; Bouzek, Drake C.; Michalski, Andrew S.; Gansemer, Nicholas D.; Reznikov, Leah R.; Li, Xiaopeng; Stroik, Mallory R.; Ostedgaard, Lynda S.; Abou Alaiwa, Mahmoud H.; Thompson, Michael A.; Prakash, Y. S.; Krishnan, Ramaswamy; Meyerholz, David K.; Seow, Chun Y.

    2016-01-01

    Rationale: An asthma-like airway phenotype has been described in people with cystic fibrosis (CF). Whether these findings are directly caused by loss of CF transmembrane conductance regulator (CFTR) function or secondary to chronic airway infection and/or inflammation has been difficult to determine. Objectives: Airway contractility is primarily determined by airway smooth muscle. We tested the hypothesis that CFTR is expressed in airway smooth muscle and directly affects airway smooth muscle contractility. Methods: Newborn pigs, both wild type and with CF (before the onset of airway infection and inflammation), were used in this study. High-resolution immunofluorescence was used to identify the subcellular localization of CFTR in airway smooth muscle. Airway smooth muscle function was determined with tissue myography, intracellular calcium measurements, and regulatory myosin light chain phosphorylation status. Precision-cut lung slices were used to investigate the therapeutic potential of CFTR modulation on airway reactivity. Measurements and Main Results: We found that CFTR localizes to the sarcoplasmic reticulum compartment of airway smooth muscle and regulates airway smooth muscle tone. Loss of CFTR function led to delayed calcium reuptake following cholinergic stimulation and increased myosin light chain phosphorylation. CFTR potentiation with ivacaftor decreased airway reactivity in precision-cut lung slices following cholinergic stimulation. Conclusions: Loss of CFTR alters porcine airway smooth muscle function and may contribute to the airflow obstruction phenotype observed in human CF. Airway smooth muscle CFTR may represent a therapeutic target in CF and other diseases of airway narrowing. PMID:26488271

  5. [Orthodontics and the upper airway].

    PubMed

    Cobo Plana, J; de Carlos Villafranca, F; Macías Escalada, E

    2004-03-01

    One of the general aims of orthodontic treatment and of the combination of orthodontics and orthognathic surgery is to achieve good occlusion and aesthetic improvement, especially in cases of severe dentoskeletal deformities. However, on many occasions, the parameters of the upper airways are not taken into account when the aims of conventional treatment are fulfilled. Patients with obstructive alterations during sleep represent for the orthodontist a type of patient who differs from the normal; for them, treatment should include the objective of improving oxygen saturation. Here, functional considerations should outweigh purely aesthetic ones. It is important, when making an orthodontic, surgical or combined diagnosis for a patient, to bear in mind the impact that treatment may have on the upper airways. Good aesthetics should never be achieved for some of our patients at the expense of diminishing the capacity of their upper airways.

  6. Airway surface liquid volume expansion induces rapid changes in amiloride-sensitive Na+ transport across upper airway epithelium-Implications concerning the resolution of pulmonary edema

    PubMed Central

    Azizi, Fouad; Arredouani, Abdelilah; Mohammad, Ramzi M

    2015-01-01

    During airway inflammation, airway surface liquid volume (ASLV) expansion may result from the movement of plasma proteins and excess liquid into the airway lumen due to extravasation and elevation of subepithelial hydrostatic pressure. We previously demonstrated that elevation of submucosal hydrostatic pressure increases airway epithelium permeability resulting in ASLV expansion by 500 μL cm−2 h−1. Liquid reabsorption by healthy airway epithelium is regulated by active Na+ transport at a rate of 5 μL cm−2 h−1. Thus, during inflammation the airway epithelium may be submerged by a large volume of luminal liquid. Here, we have investigated the mechanism by which ASLV expansion alters active epithelial Na+ transport, and we have characterized the time course of the change. We used primary cultures of tracheal airway epithelium maintained under air interface (basal ASLV, depth is 7 ± 0.5 μm). To mimic airway flooding, ASLV was expanded to a depth of 5 mm. On switching from basal to expanded ASLV conditions, short-circuit current (Isc, a measure of total transepithelial active ion transport) declined by 90% with a half-time (t1/2) of 1 h. 24 h after the switch, there was no significant change in ATP concentration nor in the number of functional sodium pumps as revealed by [3H]-ouabain binding. However, amiloride-sensitive uptake of 22Na+ was reduced by 70% upon ASLV expansion. This process is reversible since after returning cells back to air interface, Isc recovered with a t1/2 of 5–10 h. These results may have important clinical implications concerning the development of Na+ channels activators and resolution of pulmonary edema. PMID:26333829

  7. An Anesthesiologist's Perspective on the History of Basic Airway Management: The "Preanesthetic" Era-1700 to 1846.

    PubMed

    Matioc, Adrian A

    2016-02-01

    Basic airway management modern history starts in the early 18th century in the context of resuscitation of the apparently dead. History saw the rise and fall of the mouth-to-mouth and then of the instrumental positive-pressure ventilation generated by bellows. Pulmonary ventilation had a secondary role to external and internal organ stimulation in resuscitation of the apparently dead. Airway access for the extraglottic technique was to the victim's nose. The bellows-to-nose technique was the "basic airway management technique" applicable by both medical and nonmedical personnel. Although the techniques had been described at the time, very few physicians practiced glottic (intubation) and subglottic (tracheotomy) techniques. Before the anesthetic era, positive-pressure ventilation was discredited and replaced by manual negative-pressure techniques. In the middle of the 19th century, physicians who would soon administer anesthetic gases were unfamiliar with the positive-pressure ventilation concept.

  8. Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis

    PubMed Central

    Ahn, Eun Jin; Choi, Geun Joo; Kang, Hyun; Baek, Chong Wha; Jung, Yong Hun; Woo, Young Cheol; Bang, Si Ra

    2016-01-01

    Air-Q® (air-Q) is a supraglottic airway device which can be used as a guidance of intubation in pediatric as well as in adult patients. We evaluated the efficacy and safety of air-Q compared to other airway devices during general anesthesia in pediatric patients by conducting a systematic review and meta-analysis. A total of 10 studies including 789 patients were included in the final analysis. Compared with other supraglottic airway devices, air-Q showed no evidence for a difference in leakage pressure and insertion time. The ease of insertion was significantly lower than other supraglottic airway devices. The success rate of intubation was significantly lower than other airway devices. However, fiberoptic view was better through the air-Q than other supraglottic airway devices. Therefore, air-Q could be a safe substitute for other airway devices and may provide better fiberoptic bronchoscopic view. PMID:27419134

  9. Mouth-opening increases upper-airway collapsibility without changing resistance during midazolam sedation.

    PubMed

    Ayuse, T; Inazawa, T; Kurata, S; Okayasu, I; Sakamoto, E; Oi, K; Schneider, H; Schwartz, A R

    2004-09-01

    Sedative doses of anesthetic agents affect upper-airway function. Oral-maxillofacial surgery is frequently performed on sedated patients whose mouths must be as open as possible if the procedures are to be accomplished successfully. We examined upper-airway pressure-flow relationships in closed mouths, mouths opened moderately, and mouths opened maximally to test the hypothesis that mouth-opening compromises upper-airway patency during midazolam sedation. From these relationships, upper-airway critical pressure (Pcrit) and upstream resistance (Rua) were derived. Maximal mouth-opening increased Pcrit to -3.6 +/- 2.9 cm H2O compared with -8.7 +/- 2.8 (p = 0.002) for closed mouths and -7.2 +/- 4.1 (p = 0.038) for mouths opened moderately. In contrast, Rua was similar in all three conditions (18.4 +/- 6.6 vs. 17.7 +/- 7.6 vs. 21.5 +/- 11.6 cm H2O/L/sec). Moreover, maximum mouth-opening produced an inspiratory airflow limitation at atmosphere that was eliminated when nasal pressure was adjusted to 4.3 +/- 2.7 cm H2O. We conclude that maximal mouth-opening increases upper-airway collapsibility, which contributes to upper-airway obstruction at atmosphere during midazolam sedation.

  10. Airway Assessment for Office Sedation/Anesthesia.

    PubMed

    Rosenberg, Morton B; Phero, James C

    2015-01-01

    Whenever a patient is about to receive sedation or general anesthesia, no matter what the technique, the preoperative assessment of the airway is one of the most important steps in ensuring patient safety and positive outcomes. This article, Part III in the series on airway management, is directed at the ambulatory office practice and focuses on predicting the success of advanced airway rescue techniques.

  11. Cenpj/CPAP regulates progenitor divisions and neuronal migration in the cerebral cortex downstream of Ascl1

    PubMed Central

    Garcez, Patricia P.; Diaz-Alonso, Javier; Crespo-Enriquez, Ivan; Castro, Diogo; Bell, Donald; Guillemot, François

    2015-01-01

    The proneural factor Ascl1 controls multiple steps of neurogenesis in the embryonic brain, including progenitor division and neuronal migration. Here we show that Cenpj, also known as CPAP, a microcephaly gene, is a transcriptional target of Ascl1 in the embryonic cerebral cortex. We have characterized the role of Cenpj during cortical development by in utero electroporation knockdown and found that silencing Cenpj in the ventricular zone disrupts centrosome biogenesis and randomizes the cleavage plane orientation of radial glia progenitors. Moreover, we show that downregulation of Cenpj in post-mitotic neurons increases stable microtubules and leads to slower neuronal migration, abnormal centrosome position and aberrant neuronal morphology. Moreover, rescue experiments shows that Cenpj mediates the role of Ascl1 in centrosome biogenesis in progenitor cells and in microtubule dynamics in migrating neurons. These data provide insights into genetic pathways controlling cortical development and primary microcephaly observed in humans with mutations in Cenpj. PMID:25753651

  12. Comments to Role of upper airway ultrasound in airway management.

    PubMed

    Lien, Wan-Ching

    2017-01-01

    Tracheal ultrasound can be an alternative diagnostic tool in airway management, besides traditional confirmatory methods such as capnography and auscultation. The standard image is a hyperechoic air-mucosa (A-M) interface with a reverberation artifact posteriorly (comet-tail artifact). If the second A-M interface appears, which we call a "double-tract sign," esophageal intubation is considered.

  13. Computational Fluid Dynamic Analysis of the Posterior Airway Space After Maxillomandibular Advancement For Obstructive Sleep Apnea Syndrome

    PubMed Central

    Sittitavornwong, Somsak; Waite, Peter D.; Shih, Alan M.; Cheng, Gary C.; Koomullil, Roy; Ito, Yasushi; Cure, Joel K; Harding, Susan M.; Litaker, Mark

    2013-01-01

    Purpose Evaluate the soft tissue change of the upper airway after maxillomandibular advancement (MMA) by computational fluid dynamics (CFD). Materials and Methods Eight OSAS patients who required MMA were recruited into this study. All participants had pre- and post-operative computed tomography (CT) and underwent MMA by a single oral and maxillofacial surgeon. Upper airway CT data sets for these 8 participants were created with high-fidelity 3-D numerical models for computational fluid dynamics (CFD). The 3-D models were simulated and analyzed to study how changes in airway anatomy affects pressure effort required for normal breathing. Airway dimensions, skeletal changes, Apnea-Hypopnea Index (AHI), and pressure efforts of pre- and post-operative 3-D models were compared and correlations interpreted. Results After MMA, laminar and turbulent air flow was significantly decreased at every level of the airway. The cross-sectional areas at the soft palate and tongue base were significantly increased. Conclusions This study shows that MMA increases airway dimensions by the increasing the occipital base (Base) - pogonion (Pg) distance. An increase of the Base-Pg distance showed a significant correlation with an AHI improvement and a decreased pressure effort of the upper airway. Decreasing the pressure effort will decrease the breathing workload. This improves the condition of OSAS. PMID:23642544

  14. Is I-gel airway a better option to endotracheal tube airway for sevoflurane-fentanyl anesthesia during cardiac surgery?

    PubMed Central

    Elgebaly, Ahmed Said; Eldabaa, Ahmed Ali

    2014-01-01

    Background: Anesthetists used lower doses of fentanyl, successfully with hemodynamic control by titrating volatile anesthetic agents or vasodilators for fast-tracking in cardiac surgery. Hypothesis: Lower total doses of anesthetics and fentanyl could be required with hemodynamic control by use of supraglottic devices than endotracheal tube (ETT) and helps in fast-tracking. Design: A prospective randomized observational clinical trial study. Aims: The authors compared the utility of I-gel airway with a conventional ETT during the induction and maintenance of anesthesia with sevoflurane and fentanyl in adults undergoing cardiac surgery. Patients and Methods: A total of 49 adult patients underwent cardiac surgery were randomized into two groups according to the airway management: I-gel group (n = 23) and ETT group (n = 26). Doses of fentanyl and hemodynamic parameters (heart rate [HR], mean arterial pressure [MAP] central venous pressure [CVP], pulmonary artery pressure [PAP], and pulmonary capillary wedge pressure [PCWP]) were recorded preoperative, 5 min following tracheal intubation or I-gel airway insertion, after skin incision, after stenotomy, and after weaning off bypass. Results: None of the patients in the I-gel group required additional doses of fentanyl during the I-gel insertion, compared with 74% of the patients during laryngoscopy and endotracheal insertion in the ETT group, for an average total dose of 22.6 ± 0.6 μg/kg. The MAP and HR did not significantly differ from the baseline values at any point of measurement in either group. Furthermore, CVP, PAP, and PCWP measured during the procedure were significantly lower in I-gel group than ETT group. Extubation required more amount of time in ETT than I- gel group. Conclusion: The I-gel airway is well-tolerated by adult patients undergoing cardiac surgery, and requires lower total doses of anesthetics than endotracheal intubation with hemodynamic control and helps in fast-tracking. PMID:25886229

  15. A pilot study to examine the effect of the Tulip oropharyngeal airway on ventilation immediately after mask ventilation following the induction of anaesthesia.

    PubMed

    Robinson, P N; Shaikh, A; Sabir, N M; Vaughan, D J A; Kynoch, M; Hasan, M

    2014-07-01

    The Tulip airway is an adult, disposable, single-sized oropharyngeal airway, that is connectable to an anaesthetic circuit. After a standardised induction of anaesthesia in 75 patients, the ease of insertion, intracuff pressure and intracuff volume were measured, as were the end-tidal carbon dioxide levels, airway pressures and tidal volumes over three breaths. Successful first-time insertion was achieved in 72 patients (96%, CI 88.8-99.2%) and after two attempts in 74 patients (99%, CI 92.8-100%). There was outright failure only in one patient. In 60 patients (80%, CI 72.2-90.4%), the Tulip airway provided a patent airway without additional manoeuvres, but in 14 patients, jaw thrust or head extension was necessary for airway patency. The main need for these adjuncts appeared to be an initial under-inflation of the cuff. These promising results are consistent with recent manikin studies using this device.

  16. Positive expiratory pressure and oscillatory positive expiratory pressure therapies.

    PubMed

    Myers, Timothy R

    2007-10-01

    Airway clearance techniques, historically referred to as chest physical therapy, have traditionally consisted of a variety of breathing maneuvers or exercises and manual percussion and postural drainage. The methods and types of airway clearance techniques and devices have rapidly increased in an effort to find a more efficacious strategy that allows for self-therapy, better patient adherence and compliance, and more efficient durations of care. Mechanically applied pressure devices have migrated from European countries over the last several decades to clinical practice in the United States. I conducted a comprehensive MEDLINE search of two such devices: positive expiratory pressure (PEP) and oscillatory positive expiratory pressure (OPEP) and their role in airway clearance strategies. This was followed by a comprehensive search for cross-references in an attempt to identify additional studies. The results of that search are contained and reported in this review. From a methods standpoint, most of the studies of PEP and OPEP for airway clearance are limited by crossover designs and small sample sizes. While PEP and OPEP do not definitively prove superiority to other methods of airway clearance strategies, there is no clear evidence that they are inferior. Ultimately, the correct choice may be an airway clearance strategy that is clinically and cost effective, and is preferred by the patient so that adherence and compliance can be at the very least supported.

  17. The Lung Microbiome and Airway Disease.

    PubMed

    Lynch, Susan V

    2016-12-01

    A growing body of literature has demonstrated relationships between the composition of the airway microbiota (mixed-species communities of microbes that exist in the respiratory tract) and critical features of immune response and pulmonary function. These studies provide evidence that airway inflammatory status and capacity for repair are coassociated with specific taxonomic features of the airway microbiome. Although directionality has yet to be established, the fact that microbes are known drivers of inflammation and tissue damage suggests that in the context of chronic inflammatory airway disease, the composition and, more importantly, the function, of the pulmonary microbiome represent critical factors in defining airway disease outcomes.

  18. Airway nerves: in vitro electrophysiology.

    PubMed

    Fox, Alyson

    2002-06-01

    Recording the activity of single airway sensory fibres or neuronal cell bodies in vitro has allowed detailed characterisation of fibre types and membrane properties. Fibre types can be identified by their conduction velocities and further studied by the application of drugs to their receptive field. C-fibres are sensitive to mechanical stimuli and a range of irritant chemicals (bradykinin, capsaicin, low pH, platelet-activating factor), whereas Adelta-fibres are relatively insensitive to chemical stimuli and appear to correlate to the rapidly adapting receptors identified in airways in vivo. Their site of origin also differs: upper airway C-fibres arise predominantly from the jugular ganglion and Adelta-fibres from the jugular and nodose ganglia. Intracellular recording from cell bodies in the ganglia has revealed a calcium-dependent potassium current common to many putative C-fibre cell bodies. This slow after hyperpolarisation current may be inhibited by stimuli that excite and sensitise C-fibres - this could be an important mechanism underlying the sensitisation of C-fibres in airway irritability.

  19. Republication: All India Difficult Airway Association 2016 Guidelines for Tracheal Intubation in the Intensive Care Unit

    PubMed Central

    Myatra, Sheila Nainan; Ahmed, Syed Moied; Kundra, Pankaj; Garg, Rakesh; Ramkumar, Venkateswaran; Patwa, Apeksh; Shah, Amit; Raveendra, Ubaradka S.; Shetty, Sumalatha Radhakrishna; Doctor, Jeson Rajan; Pawar, Dilip K.; Ramesh, Singaravelu; Das, Sabyasachi; Divatia, Jigeeshu Vasishtha

    2017-01-01

    Tracheal intubation (TI) is a routine procedure in the Intensive Care Unit (ICU) and is often lifesaving. In contrast to the controlled conditions in the operating room, critically ill patients with respiratory failure and shock are physiologically unstable. These factors, along with under evaluation of the airway and suboptimal response to preoxygenation, are responsible for a high incidence of life-threatening complications such as severe hypoxemia and cardiovascular collapse during TI in the ICU. The All India Difficult Airway Association (AIDAA) proposes a stepwise plan for safe management of the airway in critically ill patients. These guidelines have been developed based on available evidence; Wherever, robust evidence was lacking, recommendations were arrived at by consensus opinion of airway experts, incorporating the responses to a questionnaire sent to members of the (AIDAA) and Indian Society of Anaesthesiologists. Noninvasive positive pressure ventilation for preoxygenation provides adequate oxygen stores during TI for patients with respiratory pathology. Nasal insufflation of oxygen at 15 L/min can increase the duration of apnea before hypoxemia sets in. High flow nasal cannula oxygenation at 60–70 L/min may also increase safety during intubation of critically ill patients. Stable hemodynamics and gas exchange must be maintained during rapid sequence induction. It is necessary to implement an intubation protocol during routine airway management in the ICU. Adherence to a plan for difficult airway management incorporating the use of intubation aids and airway rescue devices and strategies is useful.

  20. Airway malacia in children with achondroplasia.

    PubMed

    Dessoffy, Kimberly E; Modaff, Peggy; Pauli, Richard M

    2014-02-01

    This study was undertaken to assess the frequency of airway malacia in infants and young children with achondroplasia, a population well known to be at risk for a variety of respiratory problems. We also wished to evaluate what, if any, contribution airway malacia makes to the complex respiratory issues that may be present in those with achondroplasia. Retrospective chart review of all infants and young children with achondroplasia who were assessed through the Midwest Regional Bone Dysplasia Clinics from 1985 through 2012 (n = 236) was completed. Records of comprehensive clinical examinations, polysomnographic assessments, and airway visualization were reviewed and abstracted using a data collection form. Analyses were completed comparing the group with and those without evidence for airway malacia. Thirteen of 236 patients (5.5%) were found to have airway malacia. Most of those affected had lower airway involvement (9/13). The presence of airway malacia was correlated with an increased occurrence of obstructive sleep apnea as well as need for oxygen supplementation, airway surgeries and tracheostomy placement. Although estimates of the frequency of airway malacia in the general population are limited, its frequency in children with achondroplasia appears to be much higher than any published general population estimate. The presence of airway malacia appears to confound other breathing abnormalities in this population and results in the need for more invasive airway treatments.

  1. Native Small Airways Secrete Bicarbonate

    PubMed Central

    Quinton, Paul M.

    2014-01-01

    Since the discovery of Cl− impermeability in cystic fibrosis (CF) and the cloning of the responsible channel, CF pathology has been widely attributed to a defect in epithelial Cl− transport. However, loss of bicarbonate (HCO3−) transport also plays a major, possibly more critical role in CF pathogenesis. Even though HCO3− transport is severely affected in the native pancreas, liver, and intestines in CF, we know very little about HCO3− secretion in small airways, the principle site of morbidity in CF. We used a novel, mini-Ussing chamber system to investigate the properties of HCO3− transport in native porcine small airways (∼ 1 mm φ). We assayed HCO3− transport across small airway epithelia as reflected by the transepithelial voltage, conductance, and equivalent short-circuit current with bilateral 25-mM HCO3− plus 125-mM NaGlu Ringer’s solution in the presence of luminal amiloride (10 μM). Under these conditions, because no major transportable anions other than HCO3− were present, we took the equivalent short-circuit current to be a direct measure of active HCO3− secretion. Applying selective agonists and inhibitors, we show constitutive HCO3− secretion in small airways, which can be stimulated significantly by β-adrenergic– (cAMP) and purinergic (Ca2+) -mediated agonists, independently. These results indicate that two separate components for HCO3− secretion, likely via CFTR- and calcium-activated chloride channel–dependent processes, are physiologically regulated for likely roles in mucus clearance and antimicrobial innate defenses of small airways. PMID:24224935

  2. Sarcoidosis of the upper and lower airways.

    PubMed

    Morgenthau, Adam S; Teirstein, Alvin S

    2011-12-01

    Sarcoidosis is a systemic granulomatous disease of undetermined etiology characterized by a variable clinical presentation and disease course. Although clinical granulomatous inflammation may occur within any organ system, more than 90% of sarcoidosis patients have lung disease. Sarcoidosis is considered an interstitial lung disease that is frequently characterized by restrictive physiologic dysfunction on pulmonary function tests. However, sarcoidosis also involves the airways (large and small), causing obstructive airways disease. It is one of a few interstitial lung diseases that affects the entire length of the respiratory tract - from the nose to the terminal bronchioles - and causes a broad spectrum of airways dysfunction. This article examines airway dysfunction in sarcoidosis. The anatomical structure of the airways is the organizational framework for our discussion. We discuss sarcoidosis involving the nose, sinuses, nasal passages, larynx, trachea, bronchi and small airways. Common complications of airways disease, such as, atelectasis, fibrosis, bullous leions, bronchiectasis, cavitary lesions and mycetomas, are also reviewed.

  3. Liquid plug propagation in flexible microchannels: A small airway model

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Fujioka, H.; Bian, S.; Torisawa, Y.; Huh, D.; Takayama, S.; Grotberg, J. B.

    2009-07-01

    In the present study, we investigate the effect of wall flexibility on the plug propagation and the resulting wall stresses in small airway models with experimental measurements and numerical simulations. Experimentally, a flexible microchannel was fabricated to mimic the flexible small airways using soft lithography. Liquid plugs were generated and propagated through the microchannels. The local wall deformation is observed instantaneously during plug propagation with the maximum increasing with plug speed. The pressure drop across the plug is measured and observed to increase with plug speed, and is slightly smaller in a flexible channel compared to that in a rigid channel. A computational model is then presented to model the steady plug propagation through a flexible channel corresponding to the middle plane in the experimental device. The results show qualitative agreements with experiments on wall shapes and pressure drops and the discrepancies bring up interesting questions on current field of modeling. The flexible wall deforms inward near the plug core region, the deformation and pressure drop across the plug increase with the plug speed. The wall deformation and resulting stresses vary with different longitudinal tensions, i.e., for large wall longitudinal tension, the wall deforms slightly, which causes decreased fluid stress and stress gradients on the flexible wall comparing to that on rigid walls; however, the wall stress gradients are found to be much larger on highly deformable walls with small longitudinal tensions. Therefore, in diseases such as emphysema, with more deformable airways, there is a high possibility of induced injuries on lining cells along the airways because of larger wall stresses and stress gradients.

  4. Airway remodeling in asthma: what really matters.

    PubMed

    Fehrenbach, Heinz; Wagner, Christina; Wegmann, Michael

    2017-03-01

    Airway remodeling is generally quite broadly defined as any change in composition, distribution, thickness, mass or volume and/or number of structural components observed in the airway wall of patients relative to healthy individuals. However, two types of airway remodeling should be distinguished more clearly: (1) physiological airway remodeling, which encompasses structural changes that occur regularly during normal lung development and growth leading to a normal mature airway wall or as an acute and transient response to injury and/or inflammation, which ultimately results in restoration of a normal airway structures; and (2) pathological airway remodeling, which comprises those structural alterations that occur as a result of either disturbed lung development or as a response to chronic injury and/or inflammation leading to persistently altered airway wall structures and function. This review will address a few major aspects: (1) what are reliable quantitative approaches to assess airway remodeling? (2) Are there any indications supporting the notion that airway remodeling can occur as a primary event, i.e., before any inflammatory process was initiated? (3) What is known about airway remodeling being a secondary event to inflammation? And (4), what can we learn from the different animal models ranging from invertebrate to primate models in the study of airway remodeling? Future studies are required addressing particularly pheno-/endotype-specific aspects of airway remodeling using both endotype-specific animal models and "endotyped" human asthmatics. Hopefully, novel in vivo imaging techniques will be further advanced to allow monitoring development, growth and inflammation of the airways already at a very early stage in life.

  5. Acute exposure to hair bleach causes airway hyperresponsiveness in a rabbit model.

    PubMed

    Mensing, T; Marek, W; Raulf-Heimsoth, M; Baur, X

    1998-12-01

    Ammonium persulphate (APS) and hydrogen peroxide (H2O2) are used as oxidants in many industrial processes and are the main constituents of standard hair bleaching products. In a previous study, it was demonstrated that aerosols of APS induce alterations in airway responsiveness. The present study examined whether exposure for 4 h to a hair bleach composition (containing APS, potassium persulphate and H2O2) or H2O2 could induce airway hyperresponsiveness and/or an obstructive ventilation pattern in a rabbit model. Exposure to the aerosols altered neither baseline airway resistance, dynamic elastance, slope of inspiratory pressure generation nor arterial blood pressure and blood gas measurements. Similarly to APS, hair bleach aerosols containing > or =10.9 mg x m(-3) persulphate (ammonium and potassium salt) in air and > or =1.36 mg x m(-3) H2O2 in air caused airway hyperresponsiveness to acetylcholine after 4 h of exposure. Aerosolized H2O2 (> or =37 mg x m(-3) in air) did not influence airway responsiveness to acetylcholine. The results demonstrate that hair bleaching products containing persulphates dissolved in H2O2 cause airway hyperresponsiveness to acetylcholine in rabbits.

  6. Application of the laryngeal mask airway for anesthesia in three chimpanzees and one gibbon.

    PubMed

    Johnson, Jacob A; Atkins, Adrienne L; Heard, Darryl J

    2010-09-01

    Three pediatric chimpanzees and one pediatric gibbon were anesthetized for routine physical examination. Anesthesia was maintained with inhalant delivered via a laryngeal mask airway (LMA). The LMA was easy to insert, provided adequate control of the airway for ventilation, and caused no tracheal stimulation. No complications were observed. As compared with a face mask, the LMA has the advantage of a more secure airway; the ability to effectively ventilate the patient; less dead space, which leads to lower rebreathing of carbon dioxide; and less exposure of personnel to waste gases. As compared with an endotracheal tube, the LMA causes less airway trauma, is easier to place, and is less stimulating to the patient. The LMA should be considered for use in fasted non-human primates presented for procedures lasting less than 60 min where high peak inspiratory pressures are not needed.

  7. Validation of computational fluid dynamics methodology used for human upper airway flow simulations.

    PubMed

    Mylavarapu, Goutham; Murugappan, Shanmugam; Mihaescu, Mihai; Kalra, Maninder; Khosla, Sid; Gutmark, Ephraim

    2009-07-22

    An anatomically accurate human upper airway model was constructed from multiple magnetic resonance imaging axial scans. This model was used to conduct detailed Computational Fluid Dynamics (CFD) simulations during expiration, to investigate the fluid flow in the airway regions where obstruction could occur. An identical physical model of the same airway was built using stereo lithography. Pressure and velocity measurements were conducted in the physical model. Both simulations and experiments were performed at a peak expiratory flow rate of 200 L/min. Several different numerical approaches within the FLUENT commercial software framework were used in the simulations; unsteady Large Eddy Simulation (LES), steady Reynolds-Averaged Navier-Stokes (RANS) with two-equation turbulence models (i.e. k-epsilon, standard k-omega, and k-omega Shear Stress Transport (SST)) and with one-equation Spalart-Allmaras model. The CFD predictions of the average wall static pressures at different locations along the airway wall were favorably compared with the experimental data. Among all the approaches, standard k-omega turbulence model resulted in the best agreement with the static pressure measurements, with an average error of approximately 20% over all ports. The highest positive pressures were observed in the retroglossal regions below the epiglottis, while the lowest negative pressures were recorded in the retropalatal region. The latter is a result of the airflow acceleration in the narrow retropalatal region. The largest pressure drop was observed at the tip of the soft palate. This location has the smallest cross section of the airway. The good agreement between the computations and the experimental results suggest that CFD simulations can be used to accurately compute aerodynamic flow characteristics of the upper airway.

  8. Integrated care pathways for airway diseases (AIRWAYS-ICPs).

    PubMed

    Bousquet, J; Addis, A; Adcock, I; Agache, I; Agusti, A; Alonso, A; Annesi-Maesano, I; Anto, J M; Bachert, C; Baena-Cagnani, C E; Bai, C; Baigenzhin, A; Barbara, C; Barnes, P J; Bateman, E D; Beck, L; Bedbrook, A; Bel, E H; Benezet, O; Bennoor, K S; Benson, M; Bernabeu-Wittel, M; Bewick, M; Bindslev-Jensen, C; Blain, H; Blasi, F; Bonini, M; Bonini, S; Boulet, L P; Bourdin, A; Bourret, R; Bousquet, P J; Brightling, C E; Briggs, A; Brozek, J; Buhl, R; Bush, A; Caimmi, D; Calderon, M; Calverley, P; Camargos, P A; Camuzat, T; Canonica, G W; Carlsen, K H; Casale, T B; Cazzola, M; Cepeda Sarabia, A M; Cesario, A; Chen, Y Z; Chkhartishvili, E; Chavannes, N H; Chiron, R; Chuchalin, A; Chung, K F; Cox, L; Crooks, G; Crooks, M G; Cruz, A A; Custovic, A; Dahl, R; Dahlen, S E; De Blay, F; Dedeu, T; Deleanu, D; Demoly, P; Devillier, P; Didier, A; Dinh-Xuan, A T; Djukanovic, R; Dokic, D; Douagui, H; Dubakiene, R; Eglin, S; Elliot, F; Emuzyte, R; Fabbri, L; Fink Wagner, A; Fletcher, M; Fokkens, W J; Fonseca, J; Franco, A; Frith, P; Furber, A; Gaga, M; Garcés, J; Garcia-Aymerich, J; Gamkrelidze, A; Gonzales-Diaz, S; Gouzi, F; Guzmán, M A; Haahtela, T; Harrison, D; Hayot, M; Heaney, L G; Heinrich, J; Hellings, P W; Hooper, J; Humbert, M; Hyland, M; Iaccarino, G; Jakovenko, D; Jardim, J R; Jeandel, C; Jenkins, C; Johnston, S L; Jonquet, O; Joos, G; Jung, K S; Kalayci, O; Karunanithi, S; Keil, T; Khaltaev, N; Kolek, V; Kowalski, M L; Kull, I; Kuna, P; Kvedariene, V; Le, L T; Lodrup Carlsen, K C; Louis, R; MacNee, W; Mair, A; Majer, I; Manning, P; de Manuel Keenoy, E; Masjedi, M R; Melen, E; Melo-Gomes, E; Menzies-Gow, A; Mercier, G; Mercier, J; Michel, J P; Miculinic, N; Mihaltan, F; Milenkovic, B; Molimard, M; Momas, I; Montilla-Santana, A; Morais-Almeida, M; Morgan, M; N'Diaye, M; Nafti, S; Nekam, K; Neou, A; Nicod, L; O'Hehir, R; Ohta, K; Paggiaro, P; Palkonen, S; Palmer, S; Papadopoulos, N G; Papi, A; Passalacqua, G; Pavord, I; Pigearias, B; Plavec, D; Postma, D S; Price, D; Rabe, K F; Radier Pontal, F; Redon, J; Rennard, S; Roberts, J; Robine, J M; Roca, J; Roche, N; Rodenas, F; Roggeri, A; Rolland, C; Rosado-Pinto, J; Ryan, D; Samolinski, B; Sanchez-Borges, M; Schünemann, H J; Sheikh, A; Shields, M; Siafakas, N; Sibille, Y; Similowski, T; Small, I; Sola-Morales, O; Sooronbaev, T; Stelmach, R; Sterk, P J; Stiris, T; Sud, P; Tellier, V; To, T; Todo-Bom, A; Triggiani, M; Valenta, R; Valero, A L; Valiulis, A; Valovirta, E; Van Ganse, E; Vandenplas, O; Vasankari, T; Vestbo, J; Vezzani, G; Viegi, G; Visier, L; Vogelmeier, C; Vontetsianos, T; Wagstaff, R; Wahn, U; Wallaert, B; Whalley, B; Wickman, M; Williams, D M; Wilson, N; Yawn, B P; Yiallouros, P K; Yorgancioglu, A; Yusuf, O M; Zar, H J; Zhong, N; Zidarn, M; Zuberbier, T

    2014-08-01

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will add value to existing public health knowledge by: 1) proposing a common framework of care pathways for chronic respiratory diseases, which will facilitate comparability and trans-national initiatives; 2) informing cost-effective policy development, strengthening in particular those on smoking and environmental exposure; 3) aiding risk stratification in chronic disease patients, using a common strategy; 4) having a significant impact on the health of citizens in the short term (reduction of morbidity, improvement of education in children and of work in adults) and in the long-term (healthy ageing); 5) proposing a common simulation tool to assist physicians; and 6) ultimately reducing the healthcare burden (emergency visits, avoidable hospitalisations, disability and costs) while improving quality of life. In the longer term, the incidence of disease may be reduced by innovative prevention strategies. AIRWAYSICPs was initiated by Area 5 of the Action Plan B3 of the European Innovation Partnership on Active and Healthy Ageing. All stakeholders are involved (health and social care, patients, and policy makers).

  9. Comparison of laryngeal mask airway use with endotracheal intubation during anesthesia of western lowland gorillas (Gorilla gorilla gorilla).

    PubMed

    Cerveny, Shannon N; D'Agostino, Jennifer J; Davis, Michelle R; Payton, Mark E

    2012-12-01

    The laryngeal mask airway is an alternative to endotracheal intubation that achieves control of the airway by creating a seal around the larynx with an inflatable cuff. This study compared use of the laryngeal mask airway with endotracheal intubation in anesthetized western lowland gorillas (Gorilla gorilla gorilla). Eight adult gorillas were immobilized for routine and diagnostic purposes for a total of nine anesthetic events. During each anesthetic event, gorillas were either intubated (n = 4; group A) or fitted with a laryngeal mask airway (n= 5; group B). Time required to place each airway device, physiologic parameters, and arterial blood gas were measured and compared between the two groups. There were no significant differences between the two groups for time required to place airway device, heart rate, hemoglobin oxygen saturation, end-tidal carbon dioxide, arterial partial pressure of carbon dioxide, or arterial pH between the two groups. Mean arterial partial pressure of oxygen was significantly greater in group B, 15 (group A: 94 +/- 44 mm Hg; group B: 408 +/- 36 mm Hg; P= 0.0025) and 45 (group A: 104 +/- 21 mm Hg; group B: 407 +/- 77 mm Hg; P = 0.0026) min after airway device placement. Mean respiratory rate was significantly greater in group A at multiple time points. Mean arterial pressure (group A: 129 +/- 16 mm Hg; group B: 60 +/- 8 mm Hg) and diastolic blood pressure (group A: 115 +/- 21 mm Hg; group B: 36 +/- 10 mm Hg) were significantly greater in group A at the time of airway device placement. The laryngeal mask airway maintained oxygenation and ventilation effectively in all gorillas and is a useful alternative to endotracheal intubation in western lowland gorillas.

  10. Pharmacotherapy for residual excessive sleepiness and cognition in CPAP-treated patients with obstructive sleep apnea syndrome: A systematic review and meta-analysis.

    PubMed

    Avellar, Ariane B C C; Carvalho, Luciane B C; Prado, Gilmar F; Prado, Lucila B F

    2016-12-01

    Pharmacotherapy has been used as an adjunct to CPAP for treatment of residual excessive sleepiness in patients with a diagnosis of obstructive sleep apnea syndrome (OSAS). However, no studies with a high level of evidence have been conducted to support this practice and confirm its effectiveness. We conducted a meta-analysis to summarize and quantify the effects of pharmacological treatment in adults with OSAS who experience residual excessive sleepiness despite adequate CPAP use. We reviewed clinical trials that compared medications to placebo and evaluated the outcomes residual excessive sleepiness, cognition, and quality of life, as well as treatment effectiveness and safety. The MEDLINE, EMBASE, LILACS, Cochrane Central Register of Controlled Trials - CENTRAL, and PsycINFO electronic databases were searched using highly sensitive search strategies. Trials were only included if measures were taken to ensure effective CPAP treatment. Eight randomized clinical trials were included. Pharmacotherapy with modafinil and armodafinil led to improvement of excessive daytime sleepiness, attention/alertness, and clinical condition as measured with the CGI-C. No improvements in quality of life or other cognitive domains (including memory, executive function, and language) could be confirmed. Pharmacotherapy did not cause any severe adverse effects, but was associated with significant dropout rates as compared with placebo. In conclusion, although our results demonstrate the effectiveness of pharmacological treatment as an adjunct to CPAP, further investigation is necessary to improve confidence in its effects. Many findings on the impact of pharmacotherapy on cognition and quality of life were evaluated through analysis of single studies, with heterogeneity in tests and absence of standardization, which reduced certainty as to whether actual improvement occurred in these outcomes.

  11. Generation of Pig Airways using Rules Developed from the Measurements of Physical Airways

    PubMed Central

    Azad, Md Khurshidul; Mansy, Hansen A.

    2017-01-01

    Background A method for generating bronchial tree would be helpful when constructing models of the tree for benchtop experiments as well as for numerical modeling of flow or sound propagation in the airways. Early studies documented the geometric details of the human airways that were used to develop methods for generating human airway tree. However, methods for generating animal airway tree are scarcer. Earlier studies suggested that the morphology of animal airways can be significantly different from that of humans. Hence, using algorithms for the human airways may not be accurate in generating models of animal airway geometry. Objective The objective of this study is to develop an algorithm for generating pig airway tree based on the geometric details extracted from the physical measurements. Methods In the current study, measured values of branch diameters, lengths and bifurcation angles and rotation of bifurcating planes were used to develop an algorithm that is capable of generating a realistic pig airway tree. Results The generation relations between parent and daughter branches were found to follow certain trends. The diameters and the length of different branches were dependent on airway generations while the bifurcation angles were primarily dependent on bifurcation plane rotations. These relations were sufficient to develop rules for generating a model of the pig large airways. Conclusion The results suggested that the airway tree generated from the algorithm can provide an approximate geometric model of pig airways for computational and benchtop studies. PMID:28255517

  12. Recent trends in airway management

    PubMed Central

    Karlik, Joelle; Aziz, Michael

    2017-01-01

    Tracheal intubation remains a life-saving procedure that is typically not difficult for experienced providers in routine conditions. Unfortunately, difficult intubation remains challenging to predict and intubation conditions may make the event life threatening. Recent technological advances aim to further improve the ease, speed, safety, and success of intubation but have not been fully investigated. Video laryngoscopy, though proven effective in the difficult airway, may result in different intubation success rates in various settings and in different providers’ hands. The rescue surgical airway remains a rarely used but critical skill, and research continues to investigate optimal techniques. This review highlights some of the new thoughts and research on these important topics. PMID:28299194

  13. Inhaled Bordetella pertussis vaccine decreases airway responsiveness in guinea pigs.

    PubMed

    Vargas, M H; Bazán-Perkins, B; Segura, P; Campos, M G; Selman, M; Montaño, L M

    1995-01-01

    Bordetella pertussis (BP) has been used as adjuvant for experimental animal immunization, but its effects on airway responsiveness are uncertain. Three groups of guinea pigs were used: animals with a single exposure to inhaled BP vaccine (strain 134, total dose 1.24 x 10(12) germs), animals submitted to a sensitization procedure through inhalation of ovalbumin plus BP, and healthy control animals. Four weeks after inhalation of BP or after the beginning of sensitization, dose- or concentration-response curves to histamine were constructed in vivo and in vitro (tracheal and parenchymal preparations). We found that BP alone produced lower responses to histamine than control guinea pigs in vivo (insufflation pressure, p = 0.0003) and in tracheal tissues (p = 0.04), but not in parenchymal preparations. Sensitization did not modify the responsiveness compared with their respective controls. These results suggest that some BP component(s), probably pertussis toxin, causes a long lasting airway hyporesponsiveness in guinea pigs.

  14. Partial airway obstruction following manufacturing defect in laryngeal mask airway (Laryngeal Mask Silken™).

    PubMed

    Jangra, Kiran; Malhotra, Surender Kumar; Saini, Vikas

    2014-10-01

    Laryngeal mask (LM) airway is commonly used for securing airway in day-care surgeries. Various problems have been described while using LM airway. Out of those, mechanical obstruction causing airway compromise is most common. Here, we describe a case report of 4-year-old child who had partial upper airway obstruction due to LM manufacturer's defect. There was a silicon band in upper one-third of shaft of LM airway. This band was made up of the same material as that of LM airway so it was not identifiable on external inspection of transparent shaft. We suggest that such as non-transparent laryngeal mask, a transparent LM airway should also be inspected looking inside the lumen with naked eyes or by using a probe to rule out any manufacturing defect before its insertion.

  15. Lung sound analysis helps localize airway inflammation in patients with bronchial asthma

    PubMed Central

    Shimoda, Terufumi; Obase, Yasushi; Nagasaka, Yukio; Nakano, Hiroshi; Ishimatsu, Akiko; Kishikawa, Reiko; Iwanaga, Tomoaki

    2017-01-01

    Purpose Airway inflammation can be detected by lung sound analysis (LSA) at a single point in the posterior lower lung field. We performed LSA at 7 points to examine whether the technique could identify the location of airway inflammation in patients with asthma. Patients and methods Breath sounds were recorded at 7 points on the body surface of 22 asthmatic subjects. Inspiration sound pressure level (ISPL), expiration sound pressure level (ESPL), and the expiration-to-inspiration sound pressure ratio (E/I) were calculated in 6 frequency bands. The data were analyzed for potential correlation with spirometry, airway hyperresponsiveness (PC20), and fractional exhaled nitric oxide (FeNO). Results The E/I data in the frequency range of 100–400 Hz (E/I low frequency [LF], E/I mid frequency [MF]) were better correlated with the spirometry, PC20, and FeNO values than were the ISPL or ESPL data. The left anterior chest and left posterior lower recording positions were associated with the best correlations (forced expiratory volume in 1 second/forced vital capacity: r=−0.55 and r=−0.58; logPC20: r=−0.46 and r=−0.45; and FeNO: r=0.42 and r=0.46, respectively). The majority of asthmatic subjects with FeNO ≥70 ppb exhibited high E/I MF levels in all lung fields (excluding the trachea) and V50%pred <80%, suggesting inflammation throughout the airway. Asthmatic subjects with FeNO <70 ppb showed high or low E/I MF levels depending on the recording position, indicating uneven airway inflammation. Conclusion E/I LF and E/I MF are more useful LSA parameters for evaluating airway inflammation in bronchial asthma; 7-point lung sound recordings could be used to identify sites of local airway inflammation. PMID:28392708

  16. Computational modeling of unsteady surfactant-laden liquid plug propagation in neonatal airways

    NASA Astrophysics Data System (ADS)

    Olgac, Ufuk; Muradoglu, Metin

    2013-07-01

    Surfactant-free and surfactant-laden liquid plug propagation in neonatal airways in various generations representing the upper and lower airways are investigated computationally using a finite-difference/front-tracking method. Emphasis is placed on the unsteady surfactant-laden plug propagation as a model for Surfactant Replacement Therapy (SRT) and airway reopening. The numerical method is designed to solve the evolution equations of the interfacial and bulk surfactant concentrations coupled with the incompressible Navier-Stokes equations. Available experimental data for surfactant Survanta are used to relate surface tension coefficient to surfactant concentration at the interface. It is found that, for the surfactant-free case, the trailing film thickness is in good agreement with Taylor's law for plugs with plug length greater than the airway width. Mechanical stresses that could be injurious to epithelial cells such as pressure and shear stress and their gradients are maximized on the front and rear menisci with increasing magnitudes in the lower generations. These mechanical stresses, especially pressure and pressure gradient, are diminished with the introduction of surfactants. Surfactant is absorbed onto the trailing film and thickens it, eventually leading to either plug rupture or, if totally consumed prior to rupture, to steadily propagating plug. In the upper airways, initially small plugs rupture rapidly and plugs with comparable initial plug length with the airway width persist and propagate steadily. For a more effective SRT treatment, we recommend utilization of plugs with initial plug length greater than the airway width. Increasing surfactant strength or increasing the initially instilled surfactant concentration is found to be ineffective.

  17. A randomised trial to compare i-gel and ProSeal™ laryngeal mask airway for airway management in paediatric patients

    PubMed Central

    Nirupa, R; Gombar, Satinder; Ahuja, Vanita; Sharma, Preeti

    2016-01-01

    Background and Aims: i-gel™ is a newer supraglottic airway device with a unique non-inflatable cuff. We aimed to compare i-gel™ with ProSeal™ laryngeal mask airway (PLMA™) in children scheduled for surgery under general anaesthesia (GA) with controlled ventilation. Methods: This prospective, randomised controlled study was conducted in 100 surgical patients, aged 2–6 years of American Society of Anesthesiologists Physical Status I–II scheduled under GA. Patients were randomly allocated to receive either size 2 i-gel™ or PLMA™ as an airway device. The primary aim was oropharyngeal leak pressure assessed at 5 min following correct placement of the device. Secondary outcomes measured included number of attempts, ease of insertion, time of insertion, quality of initial airway, fibre-optic grading and effects on pulmonary mechanics. Statistical analysis was done using paired t-test and Chi-square test. Results: The demographic data were similar in both the groups. The oropharyngeal leak pressure in the i-gel™ group was 29.5 ± 2.5 cmH2 O as compared to 26.1 ± 3.8 cmH2 O in PLMA™ group (P = 0.002). The time taken for successful insertion in PLMA™ was longer as compared to i-gel (12.4 ± 2.7 vs. 10.2 ± 1.9 s, P = 0.007). The quality of initial airway was superior with i-gel™. The number of attempts, ease of insertion of supraglottic device, insertion of orogastric tube and pulmonary mechanics were similar in both the groups. Conclusion: Size 2 i-gel™ exhibited superior oropharyngeal leak pressure and quality of airway in paediatric patients with controlled ventilation as compared to PLMA™ although the pulmonary mechanics were similar. PMID:27761035

  18. Design of a new controller to treat the obstructive sleep apnea

    NASA Astrophysics Data System (ADS)

    Netzel, Thomas

    2002-06-01

    The obstructive sleep apnoea (OSA) is a sleep related breathing disorder caused by a relaxation of the upper airway structure during the sleep that leads to a complete closure of the upper airway. The most successful therapy is the nasal continuous positive airway pressure (nCPAP) treatment that keeps the airway opened. More recent devices use an automatic adaptation of the applied pressure. Either the forced oscillation technique (FOT) or the evaluation of the inspiration flow contour are used to evaluate the severity of obstructions. Both methods have disadvantages that may lead to wrong applied pressures. Based on the precise measurement of airflow and mask pressure during nCPAP with a Weinmann SOMNOsmart and additional polysomnography a new parameter set is presented that uses the advantage of both methods to detect the obstructive sleep apnoea. To evaluate the applicability of this parameter set to control Auto-nCPAP-devices a fuzzy-controller is designed under MATLAB/Simulink using an A/D-D/A-converter to control the blower of the SOMNOsmart during Auto-nCPAP-therapy. Obstructive events are detected and treated with a rise of nCPAP-pressure depending on the inspiratory flow requirement. The pressure is lowered after the end of flow limited phases. Although temporary low pressures no oxygen desaturation is recognized by the pulse oxymeter.

  19. Method for 3D Airway Topology Extraction

    PubMed Central

    Grothausmann, Roman; Kellner, Manuela; Heidrich, Marko; Lorbeer, Raoul-Amadeus; Ripken, Tammo; Meyer, Heiko; Kuehnel, Mark P.; Ochs, Matthias; Rosenhahn, Bodo

    2015-01-01

    In lungs the number of conducting airway generations as well as bifurcation patterns varies across species and shows specific characteristics relating to illnesses or gene variations. A method to characterize the topology of the mouse airway tree using scanning laser optical tomography (SLOT) tomograms is presented in this paper. It is used to test discrimination between two types of mice based on detected differences in their conducting airway pattern. Based on segmentations of the airways in these tomograms, the main spanning tree of the volume skeleton is computed. The resulting graph structure is used to distinguish between wild type and surfactant protein (SP-D) deficient knock-out mice. PMID:25767561

  20. Automated Lobe-Based Airway Labeling

    PubMed Central

    Gu, Suicheng; Wang, Zhimin; Siegfried, Jill M.; Wilson, David; Bigbee, William L.; Pu, Jiantao

    2012-01-01

    Regional quantitative analysis of airway morphological abnormalities is of great interest in lung disease investigation. Considering that pulmonary lobes are relatively independent functional unit, we develop and test a novel and efficient computerized scheme in this study to automatically and robustly classify the airways into different categories in terms of pulmonary lobe. Given an airway tree, which could be obtained using any available airway segmentation scheme, the developed approach consists of four basic steps: (1) airway skeletonization or centerline extraction, (2) individual airway branch identification, (3) initial rule-based airway classification/labeling, and (4) self-correction of labeling errors. In order to assess the performance of this approach, we applied it to a dataset consisting of 300 chest CT examinations in a batch manner and asked an image analyst to subjectively examine the labeled results. Our preliminary experiment showed that the labeling accuracy for the right upper lobe, the right middle lobe, the right lower lobe, the left upper lobe, and the left lower lobe is 100%, 99.3%, 99.3%, 100%, and 100%, respectively. Among these, only two cases are incorrectly labeled due to the failures in airway detection. It takes around 2 minutes to label an airway tree using this algorithm. PMID:23093951

  1. Anatomic Optical Coherence Tomography of Upper Airways

    NASA Astrophysics Data System (ADS)

    Chin Loy, Anthony; Jing, Joseph; Zhang, Jun; Wang, Yong; Elghobashi, Said; Chen, Zhongping; Wong, Brian J. F.

    The upper airway is a complex and intricate system responsible for respiration, phonation, and deglutition. Obstruction of the upper airways afflicts an estimated 12-18 million Americans. Pharyngeal size and shape are important factors in the pathogenesis of airway obstructions. In addition, nocturnal loss in pharyngeal muscular tone combined with high pharyngeal resistance can lead to collapse of the airway and periodic partial or complete upper airway obstruction. Anatomical optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images of the airway lumen without the use of ionizing radiation. In this chapter we describe the methods behind endoscopic OCT imaging and processing to generate full three dimensional anatomical models of the human airway which can be used in conjunction with numerical simulation methods to assess areas of airway obstruction. Combining this structural information with flow dynamic simulations, we can better estimate the site and causes of airway obstruction and better select and design surgery for patients with obstructive sleep apnea.

  2. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  3. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  4. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  5. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  6. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  7. Effect of ozone exposure on antigen-induced airway hyperresponsiveness in guinea pigs

    SciTech Connect

    Vargas, M.H.; Segura, P.; Campos, M.G.; Hong, E.; Montano, L.M.

    1994-12-31

    Airway hyperresponsiveness can be induced by several stimuli including antigen and ozone, both of which may be present in the air of polluted cities. Though the effect of ozone on the bronchoconstrictor response to antigen has been well described, the combined effect of these stimuli on airway hyperresponsiveness has not yet been studied. Sensitized guinea pigs with or without ozone exposure for 1 h at 3 ppm, 18 h prior to study, were challenged with a dose-response curve to histamine (0.01-1.8 {mu}g/kg, iv), and then by a second histamine dose-response curve 1 h later. Airway responses were measured as the increase in pulmonary insufflation pressure. In sensitized guinea pigs, the histamine ED50 significantly decreased after antigen challenge, demonstrating the development of airway hyperresponsiveness. Sensitized guinea pigs exposed to ozone showed airway hyperresponsiveness to histamine when compared with nonexposed animals, and such hyperresponsiveness was further enhanced after antigen challenge. We conclude that in this guinea pig model of acute allergic bronchoconstriction both antigen challenge and ozone induce airway hyperresponsiveness, while ozone exposure does not modify the development of antigen-induced hyperresponsiveness. 25 refs., 1 fig., 1 tab.

  8. The non-intubated anesthesia for airway surgery

    PubMed Central

    Nakanishi, Ryoichi

    2016-01-01

    Surgical treatment for lung cancer including airway resection following reconstruction is typically performed under general anesthesia with single-lung ventilation because it is necessary to maintain a sufficient working space and to adjust the airway pressure for the leak test. However, non-intubated thoracic surgery has been gradually developed in recent years for thoracoscopic surgery, due to its lower rate of postoperative complications, shorter hospitalization duration, and lower invasiveness than the usual single-lung anesthesia. Initially, only minor thoracoscopic surgery, including wedge resection for pneumothorax and the diagnosis of solitary pulmonary nodules, was performed under waking anesthesia. However, major thoracoscopic surgery, including segmentectomy and lobectomy, has also been performed under these conditions in some institutions due to its advantages with respect to the postoperative recovery and in-operating room time. In addition, non-intubated thoracic surgery has been performed for tracheal resection followed by reconstruction to fully explore the advantages of this surgical modality. In this article, the merits and demerits of non-intubated thoracoscopic surgery and the postoperative complications, perioperative problems and optimum selection criteria for patients for thoracic surgery (mainly airway surgery) are discussed. PMID:28066621

  9. The non-intubated anesthesia for airway surgery.

    PubMed

    Okuda, Katsuhiro; Nakanishi, Ryoichi

    2016-11-01

    Surgical treatment for lung cancer including airway resection following reconstruction is typically performed under general anesthesia with single-lung ventilation because it is necessary to maintain a sufficient working space and to adjust the airway pressure for the leak test. However, non-intubated thoracic surgery has been gradually developed in recent years for thoracoscopic surgery, due to its lower rate of postoperative complications, shorter hospitalization duration, and lower invasiveness than the usual single-lung anesthesia. Initially, only minor thoracoscopic surgery, including wedge resection for pneumothorax and the diagnosis of solitary pulmonary nodules, was performed under waking anesthesia. However, major thoracoscopic surgery, including segmentectomy and lobectomy, has also been performed under these conditions in some institutions due to its advantages with respect to the postoperative recovery and in-operating room time. In addition, non-intubated thoracic surgery has been performed for tracheal resection followed by reconstruction to fully explore the advantages of this surgical modality. In this article, the merits and demerits of non-intubated thoracoscopic surgery and the postoperative complications, perioperative problems and optimum selection criteria for patients for thoracic surgery (mainly airway surgery) are discussed.

  10. Peripheral airways obstruction in idiopathic pulmonary artery hypertension (primary).

    PubMed

    Fernandez-Bonetti, P; Lupi-Herrera, E; Martinez-Guerra, M L; Barrios, R; Seoane, M; Sandoval, J

    1983-05-01

    The mechanical properties of the lung were studied in ten nonsmokers with idiopathic pulmonary artery hypertension (IPAH) (mean pulmonary artery pressure 65.7 +/- 30 mm Hg). In the routine lung test, residual volume was found to be abnormal (greater than 120 percent of the predicted) in seven patients, and measured airway resistance was normal in eight out of the ten patients. A decreased FEF 75-85 percent, abnormal values for the helium-air flow ratios and increased closing capacities were documented in eight of ten patients in whom lung elastic recoil was normal (six of ten) or increased (four of ten). These features suggest peripheral airways obstruction (PAO) which was also supported by histopathologic findings in three cases (one biopsy and two necropsies). The observed changes in lung compliance could be related to the behavior of the coupling of the air-space and vascular compartments. The etiology of PAO in IPAH patients is not known, but our results indicate that both the peripheral airways and the pulmonary circulation are affected. The knowledge of PAO in IPAH patients could help to better understand the observed V/Q inequality in this entity.

  11. Airway blood flow response to dry air hyperventilation in sheep

    SciTech Connect

    Parsons, G.H.; Baile, E.M.; Pare, P.D.

    1986-03-01

    Airway blood flow (Qaw) may be important in conditioning inspired air. To determine the effect of eucapneic dry air hyperventilation (hv) on Qaw in sheep the authors studied 7 anesthetized open-chest sheep after 25 min. of warm dry air hv. During each period of hv the authors have recorded vascular pressures, cardiac output (CO), and tracheal mucosal and inspired air temperature. Using a modification of the reference flow technique radiolabelled microspheres were injected into the left atrium to make separate measurements after humid air and dry air hv. In 4 animals a snare around the left main pulmonary artery was used following microsphere injection to prevent recirculation (entry into L lung of microspheres from the pulmonary artery). Qaw to the trachea and L lung as measured and Qaw for the R lung was estimated. After the final injection the sheep were killed and bronchi (Br) and lungs removed. Qaw (trachea plus L lung plus R lung) in 4 sheep increased from a mean of 30.8 to 67.0 ml/min. Airway mucosal temp. decreased from 39/sup 0/ to 33/sup 0/C. The authors conclude that dry air hv cools airway mucosa and increases Qaw in sheep.

  12. Transient motion of mucus plugs in respiratory airways

    NASA Astrophysics Data System (ADS)

    Zamankhan, Parsa; Hu, Yingying; Helenbrook, Brian; Takayama, Shuichi; Grotberg, James B.

    2011-11-01

    Airway closure occurs in lung diseases such as asthma, cystic fibrosis, or emphysema which have an excess of mucus that forms plugs. The reopening process involves displacement of mucus plugs in the airways by the airflow of respiration. Mucus is a non-Newtonian fluid with a yield stress; therefore its behavior can be approximated by a Bingham fluid constitutive equation. In this work the reopening process is approximated by simulation of a transient Bingham fluid plug in a 2D channel. The governing equations are solved by an Arbitrary Lagrangian Eulerian (ALE) finite element method through an in-house code. The constitutive equation for the Bingham fluid is implemented through a regularization method. The effects of the yield stress on the flow features and wall stresses are discussed with applications to potential injuries to the airway epithelial cells which form the wall. The minimum driving pressure for the initiation of the motion is computed and its value is related to the mucus properties and the plug shape. Supported by HL84370 and HL85156.

  13. Effect of hypoxia and hypercapina on the airways defence reflexes.

    PubMed

    Tatár, M; Tarkanov, I A; Korpás, J; Kulik, A M

    1987-01-01

    In experiments on 10 adult anaesthetized cats (pentobarbital 30 mg.kg-1 i.p.) the effect of stimultaneous hypoxia and hypercapnia was studied on the defence respiratory reflexes of the airways. Expiratory reflex and cough were elicited by mechanical stimulation of the airways mucosa, and the obtained values were evaluated on basis of the intrapleural pressure. Inhalation of the hypoxic-hypercapnic gas mixture (11% + 7% CO2 in N2) for 15 minutes led to a significant decrease of respiratory frequency, tidal volume and PaCO2, while pHa and PaCO2 also decreased significantly together with the intensity of the expiratory reflex and that of cough. Recent studies, showed that in the course of the effect of hypoxia (11% O2) and of hypercapnia (5% CO2), cough intensity decreased, but the change was not significant. The decrease of the intensity of respiratory defence reflexes under hypoxic-hypercapnic conditions might have been due to the changes of centrally controlling structures, or to the effector part of the reflex arc, resulting from fatigue of the respiratory muscles. The possible effect of anaesthesia exerting a significant influence on the intensity and character of airways defence reflexes could not be excluded.

  14. Airway management: induced tension pneumoperitoneum

    PubMed Central

    Ahmed, Khedher; Amine, El Ghali Mohamed; Abdelbaki, Azouzi; Jihene, Ayachi; Khaoula, Meddeb; Yamina, Hamdaoui; Mohamed, Boussarsar

    2016-01-01

    Pneumoperitoneum is not always associated with hollow viscus perforation. Such condition is called non-surgical or spontaneous pneumoperitoneum. Intrathoracic causes remain the most frequently reported mechanism inducing this potentially life threatening complication. This clinical condition is associated with therapeutic dilemma. We report a case of a massive isolated pneumoperitoneum causing acute abdominal hypertension syndrome, in a 75 year female, which occurred after difficult airway management and mechanical ventilation. Emergent laparotomy yielded to full recovery. The recognition of such cases for whom surgical management can be avoided is primordial to avoid unnecessary laparotomy and its associated morbidity particularly in the critically ill.

  15. Airway smooth muscle dynamics: a common pathway of airway obstruction in asthma.

    PubMed

    An, S S; Bai, T R; Bates, J H T; Black, J L; Brown, R H; Brusasco, V; Chitano, P; Deng, L; Dowell, M; Eidelman, D H; Fabry, B; Fairbank, N J; Ford, L E; Fredberg, J J; Gerthoffer, W T; Gilbert, S H; Gosens, R; Gunst, S J; Halayko, A J; Ingram, R H; Irvin, C G; James, A L; Janssen, L J; King, G G; Knight, D A; Lauzon, A M; Lakser, O J; Ludwig, M S; Lutchen, K R; Maksym, G N; Martin, J G; Mauad, T; McParland, B E; Mijailovich, S M; Mitchell, H W; Mitchell, R W; Mitzner, W; Murphy, T M; Paré, P D; Pellegrino, R; Sanderson, M J; Schellenberg, R R; Seow, C Y; Silveira, P S P; Smith, P G; Solway, J; Stephens, N L; Sterk, P J; Stewart, A G; Tang, D D; Tepper, R S; Tran, T; Wang, L

    2007-05-01

    Excessive airway obstruction is the cause of symptoms and abnormal lung function in asthma. As airway smooth muscle (ASM) is the effecter controlling airway calibre, it is suspected that dysfunction of ASM contributes to the pathophysiology of asthma. However, the precise role of ASM in the series of events leading to asthmatic symptoms is not clear. It is not certain whether, in asthma, there is a change in the intrinsic properties of ASM, a change in the structure and mechanical properties of the noncontractile components of the airway wall, or a change in the interdependence of the airway wall with the surrounding lung parenchyma. All these potential changes could result from acute or chronic airway inflammation and associated tissue repair and remodelling. Anti-inflammatory therapy, however, does not "cure" asthma, and airway hyperresponsiveness can persist in asthmatics, even in the absence of airway inflammation. This is perhaps because the therapy does not directly address a fundamental abnormality of asthma, that of exaggerated airway narrowing due to excessive shortening of ASM. In the present study, a central role for airway smooth muscle in the pathogenesis of airway hyperresponsiveness in asthma is explored.

  16. A randomised crossover trial comparing a single-use polyvinyl chloride laryngeal mask airway with a single-use silicone laryngeal mask airway.

    PubMed

    Bell, S F; Morris, N G; Rao, A; Wilkes, A R; Goodwin, N

    2012-12-01

    We compared insertion rates of single-use polyvinyl chloride laryngeal mask airways (LMAs) vs single-use silicone LMAs in 72 anaesthetised patients. Both airways were produced by Flexicare Medical. Laryngeal mask airway insertion was successful on the first attempt in 68/72 (94%) polyvinyl chloride LMAs vs 64/72 (89%) silicone LMAs (p = 0.39). Overall insertion rates were 72/72 (100%) for the polyvinyl chloride LMAs and 71/72 (99%) for the silicone LMAs (p = 1.0). Mean (SD) insertion times were similar for polyvinyl chloride and silicone LMAs: 24.3 (5.1)s vs 24.8 (7.8)s (p = 0.64). Laryngeal mask airway position, as assessed using a fibrescope, was not different (p = 0.077). The median (IQR [range]) leak pressure was 16 (12-20 [6-30]) cmH(2) O for the polyvinyl LMA and 18 (13-22 [6-30]) cmH(2) O or the silicone LMA (p = 0.037). In conclusion, we did not find any important differences between polyvinyl chloride and silicone laryngeal mask airways.

  17. Mechanisms of inflammation-mediated airway smooth muscle plasticity and airways remodeling in asthma.

    PubMed

    Halayko, Andrew J; Amrani, Yassine

    2003-09-16

    Recent evidence points to progressive structural change in the airway wall, driven by chronic local inflammation, as a fundamental component for development of irreversible airway hyperresponsiveness. Acute and chronic inflammation is orchestrated by cytokines from recruited inflammatory cells, airway myofibroblasts and myocytes. Airway myocytes exhibit functional plasticity in their capacity for contraction, proliferation, and synthesis of matrix protein and cytokines. This confers a principal role in driving different components of the airway remodeling process, and mediating constrictor hyperresponsiveness. Functional plasticity of airway smooth muscle (ASM) is regulated by an array of environmental cues, including cytokines, which mediate their effects through receptors and a number of intracellular signaling pathways. Despite numerous studies of the cellular effects of cytokines on cultured airway myocytes, few have identified how intracellular signaling pathways modulate or induce these cellular responses. This review summarizes current understanding of these concepts and presents a model for the effects of inflammatory mediators on functional plasticity of ASM in asthma.

  18. 21 CFR 868.5110 - Oropharyngeal airway.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oropharyngeal airway. 868.5110 Section 868.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5110 Oropharyngeal airway....

  19. 21 CFR 868.5100 - Nasopharyngeal airway.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasopharyngeal airway. 868.5100 Section 868.5100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5100 Nasopharyngeal airway....

  20. SUBCHRONIC ENDOTOXIN INHALATION CAUSES PERSISTENT AIRWAY DISEASE

    EPA Science Inventory

    ABSTRACT

    The endotoxin component of organic dusts causes acute reversible airflow obstruction and airway inflammation. To test the hypothesis that endotoxin alone causes airway remodeling, we have compared the response of two inbred mouse strains to subchronic endotoxin ...

  1. Upper airway resistance: species-related differences.

    PubMed

    Kirschvink, N; Reinhold, P

    2010-07-01

    In veterinary medicine, upper airway resistance deserves a particular attention in equines athletes and brachycephalic dogs. Due to the anatomical peculiarities of the upper airway and/or pathological conditions, significant alterations of performance and/or well being might occur in horses and dogs. Physiological specificities and pathological changes of the lower respiratory tract deserve a major attention in other species.

  2. Airway and Extracellular Matrix Mechanics in COPD

    PubMed Central

    Bidan, Cécile M.; Veldsink, Annemiek C.; Meurs, Herman; Gosens, Reinoud

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is one of the most common lung diseases worldwide, and is characterized by airflow obstruction that is not fully reversible with treatment. Even though airflow obstruction is caused by airway smooth muscle contraction, the extent of airway narrowing depends on a range of other structural and functional determinants that impact on active and passive tissue mechanics. Cells and extracellular matrix in the airway and parenchymal compartments respond both passively and actively to the mechanical stimulation induced by smooth muscle contraction. In this review, we summarize the factors that regulate airway narrowing and provide insight into the relative contributions of different constituents of the extracellular matrix and their biomechanical impact on airway obstruction. We then review the changes in extracellular matrix composition in the airway and parenchymal compartments at different stages of COPD, and finally discuss how these changes impact airway narrowing and the development of airway hyperresponsiveness. Finally, we position these data in the context of therapeutic research focused on defective tissue repair. As a conclusion, we propose that future works should primarily target mild or early COPD, prior to the widespread structural changes in the alveolar compartment that are more characteristic of severe COPD. PMID:26696894

  3. Difficult Airway Response Team: A Novel Quality Improvement Program for Managing Hospital-Wide Airway Emergencies

    PubMed Central

    Mark, Lynette J.; Herzer, Kurt R.; Cover, Renee; Pandian, Vinciya; Bhatti, Nasir I.; Berkow, Lauren C.; Haut, Elliott R.; Hillel, Alexander T.; Miller, Christina R.; Feller-Kopman, David J.; Schiavi, Adam J.; Xie, Yanjun J.; Lim, Christine; Holzmueller, Christine; Ahmad, Mueen; Thomas, Pradeep; Flint, Paul W.; Mirski, Marek A.

    2015-01-01

    Background Difficult airway cases can quickly become emergencies, increasing the risk of life-threatening complications or death. Emergency airway management outside the operating room is particularly challenging. Methods We developed a quality improvement program—the Difficult Airway Response Team (DART)—to improve emergency airway management outside the operating room. DART was implemented by a team of anesthesiologists, otolaryngologists, trauma surgeons, emergency medicine physicians, and risk managers in 2005 at The Johns Hopkins Hospital in Baltimore, Maryland. The DART program had three core components: operations, safety, and education. The operations component focused on developing a multidisciplinary difficult airway response team, standardizing the emergency response process, and deploying difficult airway equipment carts throughout the hospital. The safety component focused on real-time monitoring of DART activations and learning from past DART events to continuously improve system-level performance. This objective entailed monitoring the paging system, reporting difficult airway events and DART activations to a web-based registry, and using in situ simulations to identify and mitigate defects in the emergency airway management process. The educational component included development of a multispecialty difficult airway curriculum encompassing case-based lectures, simulation, and team building/communication to ensure consistency of care. Educational materials were also developed for non-DART staff and patients to inform them about the needs of patients with difficult airways and ensure continuity of care with other providers after discharge. Results Between July 2008 and June 2013, DART managed 360 adult difficult airway events comprising 8% of all code activations. Predisposing patient factors included body mass index > 40, history of head and neck tumor, prior difficult intubation, cervical spine injury, airway edema, airway bleeding, and previous

  4. The critical airway in adults: The facts

    PubMed Central

    Bonanno, Fabrizio Giuseppe

    2012-01-01

    An algorithm on the indications and timing for a surgical airway in emergency as such cannot be drawn due to the multiplicity of variables and the inapplicability in the context of life-threatening critical emergency, where human brain elaborates decisions better in cluster rather than in binary fashion. In particular, in emergency or urgent scenarios, there is no clear or established consensus as to specifically who should receive a tracheostomy as a life-saving procedure; and more importantly, when. The two classical indications for emergency tracheostomy (laryngeal injury and failure to secure airway with endotracheal intubation or cricothyroidotomy) are too generic and encompass a broad spectrum of possibilities. In literature, specific indications for emergency tracheostomy are scattered and are biased, partially comprehensive, not clearly described or not homogeneously gathered. The review highlights the indications and timing for an emergency surgical airway and gives recommendations on which surgical airway method to use in critical airway. PMID:22787346

  5. Vocal Function and Upper Airway Thermoregulation in Five Different Environmental Conditions

    ERIC Educational Resources Information Center

    Sandage, Mary J.; Connor, Nadine P.; Pascoe, David D.

    2014-01-01

    Purpose: Phonation threshold pressure and perceived phonatory effort were hypothesized to increase and upper airway temperature to decrease following exposure to cold and/or dry air. Greater changes were expected with mouth versus nose breathing. Method: In a within-participant repeated measures design, 15 consented participants (7 men, 8 women)…

  6. Investigating the geometry of pig airways using computed tomography

    NASA Astrophysics Data System (ADS)

    Mansy, Hansen A.; Azad, Md Khurshidul; McMurray, Brandon; Henry, Brian; Royston, Thomas J.; Sandler, Richard H.

    2015-03-01

    Numerical modeling of sound propagation in the airways requires accurate knowledge of the airway geometry. These models are often validated using human and animal experiments. While many studies documented the geometric details of the human airways, information about the geometry of pig airways is scarcer. In addition, the morphology of animal airways can be significantly different from that of humans. The objective of this study is to measure the airway diameter, length and bifurcation angles in domestic pigs using computed tomography. After imaging the lungs of 3 pigs, segmentation software tools were used to extract the geometry of the airway lumen. The airway dimensions were then measured from the resulting 3 D models for the first 10 airway generations. Results showed that the size and morphology of the airways of different animals were similar. The measured airway dimensions were compared with those of the human airways. While the trachea diameter was found to be comparable to the adult human, the diameter, length and branching angles of other airways were noticeably different from that of humans. For example, pigs consistently had an early airway branching from the trachea that feeds the superior (top) right lung lobe proximal to the carina. This branch is absent in the human airways. These results suggested that the human geometry may not be a good approximation of the pig airways and may contribute to increasing the errors when the human airway geometric values are used in computational models of the pig chest.

  7. Intrathoracic airway measurement: ex-vivo validation

    NASA Astrophysics Data System (ADS)

    Reinhardt, Joseph M.; Raab, Stephen A.; D'Souza, Neil D.; Hoffman, Eric A.

    1997-05-01

    High-resolution x-ray CT (HRCT) provides detailed images of the lungs and bronchial tree. HRCT-based imaging and quantitation of peripheral bronchial airway geometry provides a valuable tool for assessing regional airway physiology. Such measurements have been sued to address physiological questions related to the mechanics of airway collapse in sleep apnea, the measurement of airway response to broncho-constriction agents, and to evaluate and track the progression of disease affecting the airways, such as asthma and cystic fibrosis. Significant attention has been paid to the measurements of extra- and intra-thoracic airways in 2D sections from volumetric x-ray CT. A variety of manual and semi-automatic techniques have been proposed for airway geometry measurement, including the use of standardized display window and level settings for caliper measurements, methods based on manual or semi-automatic border tracing, and more objective, quantitative approaches such as the use of the 'half-max' criteria. A recently proposed measurements technique uses a model-based deconvolution to estimate the location of the inner and outer airway walls. Validation using a plexiglass phantom indicates that the model-based method is more accurate than the half-max approach for thin-walled structures. In vivo validation of these airway measurement techniques is difficult because of the problems in identifying a reliable measurement 'gold standard.' In this paper we report on ex vivo validation of the half-max and model-based methods using an excised pig lung. The lung is sliced into thin sections of tissue and scanned using an electron beam CT scanner. Airways of interest are measured from the CT images, and also measured with using a microscope and micrometer to obtain a measurement gold standard. The result show no significant difference between the model-based measurements and the gold standard; while the half-max estimates exhibited a measurement bias and were significantly

  8. Obstructive sleep apnoea syndrome and its management

    PubMed Central

    Caruso, Daniela; Di Maria, Giuseppe

    2015-01-01

    Obstructive sleep apnoea (OSA) is a common disorder characterized by repetitive episodes of nocturnal breathing cessation due to upper airway collapse. OSA causes severe symptoms, such as excessive daytime somnolence, and is associated with a significant cardiovascular morbidity and mortality. Different treatment options are now available for an effective management of this disease. After more than three decades from its first use, continuous positive airway pressure (CPAP) is still recognized as the gold standard treatment. Nasal CPAP (nCPAP) is highly effective in controlling symptoms, improving quality of life and reducing the clinical sequelae of sleep apnoea. Other positive airway pressure modalities are available for patients intolerant to CPAP or requiring high levels of positive pressure. Mandibular advancement devices, particularly if custom made, are effective in mild to moderate OSA and provide a viable alternative for patients intolerant to CPAP therapy. The role of surgery remains controversial. Uvulopalatopharyngoplasty is a well established procedure and can be considered when treatment with CPAP has failed, whereas maxillar-mandibular surgery can be suggested to patients with a craniofacial malformation. A number of minimally invasive procedures to treat snoring are currently under evaluation. Weight loss improves symptoms and morbidity in all patients with obesity and bariatric surgery is an option in severe obesity. A multidisciplinary approach is necessary for an accurate management of the disease. PMID:26336596

  9. The status of cephalometry in the prediction of non-CPAP treatment outcome in obstructive sleep apnea patients.

    PubMed

    Denolf, Petra L; Vanderveken, Olivier M; Marklund, Marie E; Braem, Marc J

    2016-06-01

    Obstructive sleep apnea syndrome (OSAS) is the most common sleep disordered breathing disorder (SDB) in adults and is characterized by a recurrent partial or complete collapse of the upper airway during sleep. This can be caused by many factors, sometimes interacting, such as skeletal malformations, soft tissue crowding, respiratory instability and the various effects of aging, obesity and gender that dictate craniofacial and upper airway anatomy. Research has demonstrated that the majority of patients exhibit at least one anatomical component such as retrognathia or a narrow posterior airway space that predisposes to the development of OSAS. Within the predisposing elements for OSAS many seem to point to anatomical characteristics. A standardized and relatively simple radiologic technique to evaluate anatomical craniofacial relationships is cephalometry. This has been used already for a long time in orthodontics, but is now gradually being introduced in OSAS treatment to envisage optimal treatment selection as well as to predict treatment outcomes. The purpose of the present review is to evaluate the contribution of cephalometry in the prediction of outcomes from OSAS treatments that depend on the upper airway morphology in their mechanisms of action such as oral appliances that advance the mandible as well as various surgical methods. In addition, an overview of imaging modalities and methods that currently are being used in cephalometric analysis in OSAS patients is provided. The findings indicate that isolated cephalometric parameters cannot be used to reliably predict treatment outcomes from mandibular advancement devices and surgical methods for OSAS. Extreme or outlying values of cephalometric parameters may rather be used as contra-indicators or 'red flags' instead of predictors.

  10. Computational fluid dynamics for the assessment of upper airway response to oral appliance treatment in obstructive sleep apnea.

    PubMed

    Zhao, Moyin; Barber, Tracie; Cistulli, Peter; Sutherland, Kate; Rosengarten, Gary

    2013-01-04

    Mandibular advancement splints (MAS), which protrude the lower jaw during sleep, are recognized as an effective treatment for obstructive sleep apnea (OSA) through their action of enlarging the airway space and preventing upper airway collapse. However a clinical challenge remains in preselecting patients who will respond to this form of therapy. We aimed to use computational fluid dynamics (CFD) in conjunction with patient upper airway scans to understand the upper airway response to treatment. Seven OSA patients were selected based on their varied treatment response (assessed by the apnea-hypopnoea index (AHI) on overnight polysomnography). Anatomically-accurate upper airway computational models were reconstructed from magnetic resonance images with and without MAS. CFD simulations of airflow were performed at the maximum flow rate during inspiration. A physical airway model of one patient was fabricated and the CFD method was validated against the pressure profile on the physical model. The CFD analysis clearly demonstrated effects of MAS treatment on the patient's UA airflow patterns. The CFD results indicated the lowest pressure often occurs close to the soft palate and the base of the tongue. Percentage change in the square root of airway pressure gradient with MAS (Δsqrt(ΔP(Max))%) was found to have the strongest relationship with treatment response (ΔAHI%) in correlation analysis (r=0.976, p=0.000167). Changes in upper airway geometry alone did not significantly correlate with treatment response. We provide further support of CFD as a potential tool for prediction of treatment outcome with MAS in OSA patients without requiring patient specific flow rates.

  11. To characterize the incidence of airway misplacement of nasogastric tubes in anesthetized intubated patients by using a manometer technique.

    PubMed

    Hsieh, Shao-Wei; Chen, Hung-Shu; Chen, Yi-Ting; Hung, Kuo-Chuan

    2017-04-01

    This study characterized the incidence of airway misplacement of nasogastric (NG) tubes in surgical patients, and the benefit of using a manometer to discriminate gastric placement from airway placement of NG tubes. Subjects included adult patients scheduled for abdominal surgery. After tracheal intubation, a 16 Fr. NG tube was inserted blindly through the nostril, and its position was assessed using the auscultation (10-ml air insufflation) or manometer (attached to NG tubes) techniques. Briefly, a biphasic pressure change synchronous with airway pressure during mechanical ventilation indicated airway misplacement. The presence of a notable pressure change while compressing the epigastric area indicated a gastric placement. A surgeon made the final confirmation of NG tube placement within the stomach using manual palpation of the tube immediately after laparotomy. The first-attempt success rate was 82.7 % in 104 patients. There were 29 misplacements of 130 attempted insertions (oral cavity, n = 23; trachea, n = 3; distal esophagus, n = 3). The incidence of airway misplacement was 2.9 % (3 of 104 cases). For confirmation of gastric placement, the auscultation technique had a sensitivity of 100.0 % and a specificity of 79.3 %. In contrast, the manometer technique had a sensitivity of 100.0 % and a specificity of 100.0 % in the discrimination of gastric placement from airway placement of NG tubes. Airway misplacement of NG tubes is not uncommon in surgical patients, and the manometer technique may be a reliable and safe method to discriminate gastric placement from airway placement of NG tubes.

  12. Glutathione redox regulates airway hyperresponsiveness and airway inflammation in mice.

    PubMed

    Koike, Yoko; Hisada, Takeshi; Utsugi, Mitsuyoshi; Ishizuka, Tamotsu; Shimizu, Yasuo; Ono, Akihiro; Murata, Yukie; Hamuro, Junji; Mori, Masatomo; Dobashi, Kunio

    2007-09-01

    Glutathione is the major intracellular redox buffer. We have shown that glutathione redox status, which is the balance between intracellular reduced (GSH) and oxidized (GSSG) glutathione, in antigen-presenting cells (APC) regulates the helper T cell type 1 (Th1)/Th2 balance due to the production of IL-12. Bronchial asthma is a typical Th2 disease. Th2 cells and Th2 cytokines are characteristic of asthma and trigger off an inflammation. Accordingly, we studied the effects of the intracellular glutathione redox status on airway hyperresponsiveness (AHR) and allergen-induced airway inflammation in a mouse model of asthma. We used gamma-Glutamylcysteinylethyl ester (gamma-GCE), which is a membrane-permeating GSH precursor, to elevate the intracellular GSH level and GSH/GSSG ratio of mice. In vitro, gamma-GCE pretreatment of human monocytic THP-1 cells elevated the GSH/GSSG ratio and enhanced IL-12(p70) production induced by LPS. In the mouse asthma model, intraperitoneal injection of gamma-GCE elevated the GSH/GSSG ratio of lung tissue and reduced AHR. gamma-GCE reduced levels of IL-4, IL-5, IL-10, and the chemokines eotaxin and RANTES (regulated on activation, normal T cell expressed and secreted) in bronchoalveolar lavage fluid, whereas it enhanced the production of IL-12 and IFN-gamma. Histologically, gamma-GCE suppressed eosinophils infiltration. Interestingly, we also found that gamma-GCE directly inhibited chemokine-induced eosinophil chemotaxis without affecting eotaxin receptor chemokine receptor 3 (CCR3) expressions. Taken together, these findings suggest that changing glutathione redox balance, increase in GSH level, and the GSH/GSSG ratio by gamma-GCE, ameliorate bronchial asthma by altering the Th1/Th2 imbalance through IL-12 production from APC and suppressing chemokine production and eosinophil migration itself.

  13. ProSeal Laryngeal Mask Airway as an Alternative to Standard Endotracheal Tube in Securing Upper Airway in the Patients Undergoing Beating-heart Coronary Artery Bypass Grafting

    PubMed Central

    Shah, Kalpana

    2017-01-01

    Background: ProSeal laryngeal mask airways (PLMAs) are routinely used after failed tracheal intubation as airway rescue, facilitating tracheal intubation by acting as a conduit and to secure airway during emergencies. In long duration surgeries, use of endotracheal tube (ETT) is associated with various hemodynamic complications, which are minimally affected during PLMA use. However, except for few studies, there are no significant data available that promote the use of laryngeal mask during cardiac surgery. This prospective study was conducted with the objective of demonstrating the advantages of PLMA over ETT in the patients undergoing beating-heart coronary artery bypass graft (CABG). Methodology: This prospective, interventional study was carried out in 200 patients who underwent beating-heart CABG. Patients were randomized in equal numbers to either ETT group or PLMA group, and various hemodynamic and respiratory parameters were observed at different time points. Results: Patients in PLMA group had mean systolic blood pressure 126.10 ± 5.31 mmHg compared to the patients of ETT group 143.75 ± 6.02 mmHg. Pulse rate in the PLMA group was less (74.52 ± 10.79 per min) (P < 0.05) compared to ETT group (81.72 ± 9.8). Thus, hemodynamic changes were significantly lower (P < 0.05) in PLMA than in ETT group. Respiratory parameters such as oxygen saturation, pressure CO2 (pCO2), peak airway pressure, and lung compliance were similar to ETT group at all evaluation times. The incidence of adverse events was also lower in PLMA group. Conclusion: In experience hand, PLMA offers advantages over the ETT in airway management in the patients undergoing beating-heart CABG. PMID:28074798

  14. Educating the Educator: Teaching Airway Adjunct Techniques in Athletic Training

    ERIC Educational Resources Information Center

    Berry, David C.; Seitz, S. Robert

    2011-01-01

    The 5th edition of the "Athletic Training Education Competencies" ("Competencies") now requires athletic training educators (ATEs) to introduce into the curriculum various types of airway adjuncts including: (1) oropharyngeal airways (OPA), (2) nasopharyngeal airways (NPA), (3) supraglottic airways (SGA), and (4) suction. The addition of these…

  15. Airway adequacy, head posture, and craniofacial morphology.

    PubMed

    Solow, B; Siersbaek-Nielsen, S; Greve, E

    1984-09-01

    Previous studies of different samples have demonstrated associations between craniocervical angulation and craniofacial morphology, between airway obstruction by adenoids and craniofacial morphology, and between airway obstruction and craniocervical angulation. A hypothesis to account for the different sets of associations was suggested by Solow and Kreiborg in 1977. In the present study, the three sets of associations were examined in a single group of nonpathologic subjects with no history of airway obstruction. Cephalometric radiographs taken in the natural head position and rhinomanometric recordings were obtained from twenty-four children 7 to 9 years of age. Correlations were calculated between twenty-seven morphologic, eight postural, and two airway variables. A large craniocervical angle was, on the average, seen in connection with small mandibular dimensions, mandibular retrognathism, and a large mandibular inclination. Obstructed nasopharyngeal airways (defined as a small pm-ad 2 radiographic distance and a large nasal respiratory resistance, NRR, determined rhinomanometrically) were, on the average, seen in connection with a large craniocervical angle and with small mandibular dimensions, mandibular retrognathism, a large mandibular inclination, and retroclination of the upper incisors. The observed correlations were in agreement with the predicted pattern of associations between craniofacial morphology, craniocervical angulation, and airway resistance, thus suggesting the simultaneous presence of such associations in the sample of nonpathologic subjects with no history of airway obstruction.

  16. Comparison of analysis methods for airway quantification

    NASA Astrophysics Data System (ADS)

    Odry, Benjamin L.; Kiraly, Atilla P.; Novak, Carol L.; Naidich, David P.

    2012-03-01

    Diseased airways have been known for several years as a possible contributing factor to airflow limitation in Chronic Obstructive Pulmonary Diseases (COPD). Quantification of disease severity through the evaluation of airway dimensions - wall thickness and lumen diameter - has gained increased attention, thanks to the availability of multi-slice computed tomography (CT). Novel approaches have focused on automated methods of measurement as a faster and more objective means that the visual assessment routinely employed in the clinic. Since the Full-Width Half-Maximum (FWHM) method of airway measurement was introduced two decades ago [1], several new techniques for quantifying airways have been detailed in the literature, but no approach has truly become a standard for such analysis. Our own research group has presented two alternative approaches for determining airway dimensions, one involving a minimum path and the other active contours [2, 3]. With an increasing number of techniques dedicated to the same goal, we decided to take a step back and analyze the differences of these methods. We consequently put to the test our two methods of analysis and the FWHM approach. We first measured a set of 5 airways from a phantom of known dimensions. Then we compared measurements from the three methods to those of two independent readers, performed on 35 airways in 5 patients. We elaborate on the differences of each approach and suggest conclusions on which could be defined as the best one.

  17. Physiological Effects of Positive Pressure Ventilation.

    DTIC Science & Technology

    1992-05-01

    spontaneous breath (Banner, et al., 1990). This "stacking" of mechanical on spontaneous breaths could increase the peak inflation, airway , and intrapleural...J., & Gottfried, S. B. (1990). Continuous positive airway pressure reduces work of breathing and dyspnea during weaning from mechanical ventilation in...insufficiency is caused by numerous physiological aberrations, some of which can be reversed or improved by mechanical respiratory support, thus

  18. Airway smooth muscle growth in asthma: proliferation, hypertrophy, and migration.

    PubMed

    Bentley, J Kelley; Hershenson, Marc B

    2008-01-01

    Increased airway smooth muscle mass is present in fatal and non-fatal asthma. However, little information is available regarding the cellular mechanism (i.e., hyperplasia vs. hypertrophy). Even less information exists regarding the functional consequences of airway smooth muscle remodeling. It would appear that increased airway smooth muscle mass would tend to increase airway narrowing and airflow obstruction. However, the precise effects of increased airway smooth muscle mass on airway narrowing are not known. This review will consider the evidence for airway smooth muscle cell proliferation and hypertrophy in asthma, potential functional effects, and biochemical mechanisms.

  19. Myeloid sarcoma causing airway obstruction

    PubMed Central

    Krause, John R.

    2017-01-01

    Myeloid sarcoma is an extramedullary collection of blasts of the myeloid series that partially or totally effaces the architecture of the tissue in which it is found. These tumors have been described in many sites of the body, but the skin, lymph nodes, gastrointestinal tract, bone, soft tissue, and testes are most common. They can arise in a patient following the diagnosis of acute myeloid leukemia, but they may also be precursors of leukemia and should be considered diagnostic for acute myeloid leukemia. The differential diagnosis of this neoplasm includes malignant lymphoma, with which it is often mistaken, leading to diagnostic and therapeutic delays. We present the case of an 84-year-old African American man with a history of renal disease secondary to hypertension and coronary artery disease without any prior history of malignancies who presented with airway obstruction. He was diagnosed with a myeloid sarcoma of the mediastinum compressing his trachea.

  20. The Development and Application of Airway Devices in China

    PubMed Central

    Chen, Xiangdong; Ma, Wuhua; Liu, Renyu; Yao, Shanglong

    2017-01-01

    Airway management is one of the most important tasks for anesthesiologists. Anesthesiologists are experts in airway management and have made tremendous contribution to the development of the airway devices. Chinese anesthesiologists have made significant contribution in introducing advanced airway management and developing innovative techniques and devices for airway management in China. This article overviews the development and application of airway devices in China as well as the dedication and contribution of Chinese experts in the development of novel airway devices. With the development of science and technology accompanied by the advanced knowledge in airway management, more effective and safe artificial airways will be developed for clinical practice. The authors believe that Chinese experts will continue their outstanding contribution to the development of innovative airway devices, systems and knowledge. PMID:28191485

  1. Pharmacology of airway afferent nerve activity

    PubMed Central

    Undem, Bradley J; Carr, Michael J

    2001-01-01

    Afferent nerves in the airways serve to regulate breathing pattern, cough, and airway autonomic neural tone. Pharmacologic agents that influence afferent nerve activity can be subclassified into compounds that modulate activity by indirect means (e.g. bronchial smooth muscle spasmogens) and those that act directly on the nerves. Directly acting agents affect afferent nerve activity by interacting with various ion channels and receptors within the membrane of the afferent terminals. Whether by direct or indirect means, most compounds that enter the airspace will modify afferent nerve activity, and through this action alter airway physiology. PMID:11686889

  2. On locating the obstruction in the upper airway via numerical simulation

    PubMed Central

    Wang, Yong; Elghobashi, S.

    2014-01-01

    The fluid dynamical properties of the air flow in the upper airway (UA) are not fully understood at present due to the three-dimensional (3D) patient-specific complex geometry of the airway, flow transition from laminar to turbulent and flow-structure interaction during the breathing cycle. It is quite difficult at present to experimentally measure the instantaneous velocity and pressure at specific points in the human airway. On the other hand, direct numerical simulation (DNS) can predict all the flow properties and resolve all its relevant length- and time-scales. We developed a DNS solver with the state-of-the-art lattice Boltzmann method (LBM), and used it to investigate the flow in two patient-specific UAs reconstructed from CT scan data. Inspiration and expiration flows through these two airways are studied. The time-averaged first spatial derivative of pressure (pressure gradient), ∂p/∂z, is used to locate the region of the UA obstruction. But the time-averaged second spatial derivative, ∂2p/∂z2, is used to pinpoint the exact location of the obstruction. The present results show that the DNS-LBM solver can be used to obtain accurate flow details in the UA and is a powerful tool to locate its obstruction. PMID:24389271

  3. Firefighting acutely increases airway responsiveness.

    PubMed

    Sherman, C B; Barnhart, S; Miller, M F; Segal, M R; Aitken, M; Schoene, R; Daniell, W; Rosenstock, L

    1989-07-01

    The acute effects of the products of combustion and pyrolysis on airway responsiveness among firefighters are poorly documented. To study this relationship, spirometry and methacholine challenge testing (MCT) were performed on 18 active Seattle firefighters before and 5 to 24 h after firefighting. Body plethysmography was used to measure changes in specific airway conductance (SGaw), and results of MCT were analyzed using PD35-SGaw, the cumulative dose causing a 35% decrease in SGaw. Subjects who did not react by the end of the protocol were assigned a value of 640 inhalational units, the largest cumulative dose. Fire exposure was defined as the total time (hours) spent without a self-contained breathing apparatus at the firesite and was categorized as mild (less than 1 h, n = 7), moderate (1 to 2 h, n = 5), or severe (greater than 2 h, n = 6). Mean age of the 18 firefighters was 36.7 +/- 6.7 yr (range, 25 to 51), with a mean of 9.1 +/- 7.9 active years in the trade (range, zero to 22). None was known to be asthmatic. After firefighting, FEV1 % predicted (%pred) and FEF25-75 %pred significantly decreased by means of 3.4 +/- 1.1% and 5.6 +/- 2.6%, respectively. The mean decline in PD35-SGaw after firefighting was 184.5 +/- 53.2 units (p = 0.003). This observed decline in PD35-SGaw could not be explained by decrements in prechallenge SGaw, FEV1, or FVC.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. The All India Difficult Airway Association 2016 guidelines for tracheal intubation in the Intensive Care Unit

    PubMed Central

    Myatra, Sheila Nainan; Ahmed, Syed Moied; Kundra, Pankaj; Garg, Rakesh; Ramkumar, Venkateswaran; Patwa, Apeksh; Shah, Amit; Raveendra, Ubaradka S; Shetty, Sumalatha Radhakrishna; Doctor, Jeson Rajan; Pawar, Dilip K; Ramesh, Singaravelu; Das, Sabyasachi; Divatia, Jigeeshu Vasishtha

    2016-01-01

    Tracheal intubation (TI) is a routine procedure in the Intensive Care Unit (ICU) and is often life-saving. In contrast to the controlled conditions in the operating room, critically ill patients with respiratory failure and shock are physiologically unstable. These factors, along with a suboptimal evaluation of the airway and limited oxygen reserves despite adequate pre-oxygenation, are responsible for a high incidence of life-threatening complications such as severe hypoxaemia and cardiovascular collapse during TI in the ICU. The All India Difficult Airway Association (AIDAA) proposes a stepwise plan for safe management of the airway in critically ill patients. These guidelines have been developed based on available evidence; wherever robust evidence was lacking, recommendations were arrived at by consensus opinion of airway experts, incorporating the responses to a questionnaire sent to members of the AIDAA and the Indian Society of Anaesthesiologists. Non-invasive positive pressure ventilation during pre-oxygenation improves oxygen stores in patients with respiratory pathology. Nasal insufflation of oxygen at 15 L/min can increase the duration of apnoea before the occurrence of hypoxaemia. High-flow nasal cannula oxygenation at 60–70 L/min may also increase safety during TI in critically ill patients. Stable haemodynamics and gas exchange must be maintained during rapid sequence induction. It is necessary to implement an intubation protocol during routine airway management in the ICU. Adherence to a plan for difficult airway management incorporating the use of intubation aids and airway rescue devices and strategies is useful. PMID:28003694

  5. Respiratory and upper airways impedance responses to methacholine inhalation in spontaneously breathing cats.

    PubMed

    Loos, N; Peslin, R; Marchal, F

    2000-06-01

    The upper airways may contribute to the increase in respiratory resistance induced by methacholine (Mch). The aim of this study was to simultaneously assess the Mch response of upper airways and lower respiratory resistances (Rua, Rrs,lo) and reactances (Xua, Xrs,lo), and to test whether the change of total respiratory resistance and reactance after Mch were affected by upper airways mechanisms. Seven cats breathing spontaneously were studied under chloralose, urethane anaesthesia. Forced oscillations were generated at 20 Hz by a loud-speaker connected to the pharyngeal cavity. A pneumotachograph was placed between rostral and caudal extremities of the severed cervical trachea. Pressure drops were measured across the upper airways and across the lower respiratory system. Rua, Xua, Rrs,lo and Xrs,lo were obtained after nebulized normal saline and Mch administered directly through the tracheostomy. The analysis focused on Mch tests showing clear positive upper airways response. Volume and flow dependence of Rrs,lo and Rua were assessed during tidal inspiration using multiple linear regression analysis. After Mch, Rrs,lo increased and became negatively volume dependent, while the increase in Rua was associated with no significant change in volume dependence; Xrs,lo became negative while Xua did not change. The upper airways response to methacholine may thus contribute to the increase in total respiratory resistance but may not account for either its negative volume dependence or the decrease in total resistance. It is surmised that these features more specifically reflect alterations in respiratory mechanics occurring at the level of the intrathoracic airways.

  6. Ultrasonographic Detection of Airway Obstruction in a Model of Obstructive Sleep Apnea

    PubMed Central

    Isaiah, Amal; Mezrich, Reuben; Wolf, Jeffrey

    2017-01-01

    Purpose Obstructive sleep apnea (OSA) is a common clinical disorder characterized by repetitive airway obstruction during sleep. The gold standard for diagnosis of OSA, polysomnogram (PSG), cannot anatomically localize obstruction. Precise identification of obstruction has potential to improve outcomes following surgery. Current diagnostic modalities that provide this information require anesthesia, involve ionizing radiation or disrupt sleep. To mitigate these problems, we conceived that ultrasound (US) technology may be adapted (i) to detect, quantify and localize airway obstruction and (ii) for translational application to home-based testing for OSA. Materials and Methods Segmental airway collapse was induced in 4 fresh cadavers by application of negative pressure. Following visualization of airway obstruction, a rotary US probe was used to acquire transcervical images of the airway before and after induction of obstruction. These images (n=800) were analyzed offline using image processing algorithms. Results Our results show that the non-obstructed airway consistently demonstrated the presence of a US air-tissue interface. Importantly, automated detection of the air-tissue interface strongly correlated with manual measurements. The algorithm correctly detected an air-tissue interface in 90% of the US images while incorrectly detecting it in 20% (area under the curve=0.91). Conclusion The non-invasive detection of airway obstruction using US represents a major step in expanding OSA diagnostics beyond PSG. The preliminary data obtained from our model could spur further research in non-invasive localization of obstruction. US offers the benefit of precise localization of the site of obstruction, with potential for improving outcomes in surgical management PMID:28345075

  7. An Anesthesiologist's Perspective on the History of Basic Airway Management: The "Artisanal Anesthetic" Era: 1846 to 1904.

    PubMed

    Matioc, Adrian A

    2017-03-01

    This second installment of the history of basic airway management covers the early-artisanal-years of anesthesia from 1846 to 1904. Anesthesia was invented and practiced as a supporting specialty in the context of great surgical and medical advances. The current-day anesthesia provider tends to equate the history of airway management with the history of intubation, but for the first 58 yr after the introduction of ether anesthesia, airway management was provided by basic airway techniques with or without the use of a face mask. The jaw thrust and chin lift were described in the artisanal years and used primarily with inhalation anesthesia in the spontaneously breathing patient and less often with negative-pressure ventilation in the apneic victim. Positive-pressure ventilation and intubation stayed at the fringes of medical practice, and airway techniques and devices were developed by trial and error. At the beginning of the 20th century, airway management and anesthetic techniques lagged behind surgical requirements.

  8. Treatment of Foreign Body Obstruction of the Upper Airway

    PubMed Central

    Hoffman, Jerome R.

    1982-01-01

    The treatment of foreign body obstruction of the upper airway has been the subject of considerable attention and controversy. Current recommendations from the National Academy of Sciences, the American Red Cross and the American Heart Association include the use of back blows, abdominal thrusts (Heimlich maneuver) or chest thrusts (or both) and finger probes, until definitive therapy by trained medical and paramedical personnel becomes available. Nevertheless, a number of authorities on this subject have claimed that these approaches are dangerous, and that abdominal thrusts should be the first and only first-aid technique used in this situation. There are only limited data on which to make recommendations regarding this issue. Clinical evidence is scanty and of a highly anecdotal and unscientific nature. The data that are available suggest that a combination of maneuvers is in fact preferable to any single maneuver. Experimental physiologic data on both humans and animals tend to support this concept and suggest that back blows, which generate high initial pressures, may dislodge objects from the larynx enough to allow subsequent thrust maneuvers, which generate more sustained increases in intrathoracic pressure, to move the object out of the larynx. At this time, in the absence of definitive data, it seems reasonable to teach as many lay citizens as possible to recognize upper airway obstruction due to foreign body and to perform any and all of these techniques (preferably in combination), as well as external cardiopulmonary resuscitation (CPR) where appropriate, on choking victims. PMID:7072236

  9. Induction of periodic breathing during sleep causes upper airway obstruction in humans.

    PubMed

    Onal, E; Burrows, D L; Hart, R H; Lopata, M

    1986-10-01

    To test the hypothesis that occlusive apneas result from sleep-induced periodic breathing in association with some degree of upper airway compromise, periodic breathing was induced during non-rapid-eye-movement (NREM) sleep by administering hypoxic gas mixtures with and without applied external inspiratory resistance (9 cmH2O X l-1 X s) in five normal male volunteers. In addition to standard polysomnography for sleep staging and respiratory pattern monitoring, esophageal pressure, tidal volume (VT), and airflow were measured via an esophageal catheter and pneumotachograph, respectively, with the latter attached to a tight-fitting face mask, allowing calculation of total pulmonary system resistance (Rp). During stage I/II NREM sleep minimal period breathing was evident in two of the subjects; however, in four subjects during hypoxia and/or relief from hypoxia, with and without added resistance, pronounced periodic breathing developed with waxing and waning of VT, sometimes with apneic phases. Resistive loading without hypoxia did not cause periodicity. At the nadir of periodic changes in VT, Rp was usually at its highest and there was a significant linear relationship between Rp and 1/VT, indicating the development of obstructive hypopneas. In one subject without added resistance and in the same subject and in another during resistive loading, upper airway obstruction at the nadir of the periodic fluctuations in VT was observed. We conclude that periodic breathing resulting in periodic diminution of upper airway muscle activity is associated with increased upper airway resistance that predisposes upper airways to collapse.

  10. Coronary-bronchial blood flow and airway dimensions in exercise-induced syndromes.

    PubMed

    White, S W; Pitsillides, K F; Parsons, G H; Hayes, S G; Gunther, R A; Cottee, D B

    2001-01-01

    1. We have an incomplete understanding of integrative cardiopulmonary control during exercise and particularly during the postexercise period, when symptoms and signs of myocardial ischaemia and exercise-induced asthma not present during exercise may appear. 2. The hypothesis is advanced that baroreflex de-resetting during exercise recovery is normally associated with (i) a dominant sympathetic vasoconstrictor effect in the coronary circulation, which, when associated with obstructive coronary disease, may initiate a potentially positive-feedback cardiocardiac sympathetic reflex (variable myocardial ischaemia with symptoms and signs); and (ii) a dominant parasympathetic bronchoconstrictor effect in the presence of bronchovascular dilatation, which, when associated with raised mediator release in the bronchial wall, reinforces the tendency for airway obstruction (variable dyspnoea results). 3. There is a need for new techniques to examine hypotheses concerning autonomic control, during and after exercise, of the coronary and bronchial circulations and the dimensions of airways. Accordingly, a new ultrasonic instrument has been designed named an 'Airways Internal Diameter Assessment (AIDA) Sonomicrometer'. It combines pulsed Doppler flowmetry with transit-time sonomicrometry of airway circumference and single-crystal sonomicrometry of airway wall thickness. Initial evaluation suggests it is relatively easy to apply during thoracotomy in recovery animals. The component devices are linear and will measure target variables with excellent accuracy. 4. In anaesthetized sheep, intubated with controlled ventilation, intravenous isoproterenol causes large increases in bronchial blood flow, a fall in arterial pressure and a reduction in airway circumference. This may reflect the dominant action of reflex vagal activity over direct beta-adrenoceptor inhibition of bronchial smooth muscle, the reflex source being baroreflex secondary to the fall in arterial pressure. These

  11. Diesel exhaust particles and airway inflammation

    EPA Science Inventory

    Purpose of review. Epidemiologic investigation has associated traffic-related air pollution with adverse human health outcomes. The capacity ofdiesel exhaust particles (DEP), a major emission source air pollution particle, to initiate an airway inflammation has subsequently been ...

  12. Airway management for cervical spine surgery.

    PubMed

    Farag, Ehab

    2016-03-01

    Cervical spine surgery is one of the most commonly performed spine surgeries in the United States, and 90% of the cases are related to degenerative cervical spine disease (the rest to cervical spine trauma and/or instability). The airway management for cervical spine surgery represents a crucial step in the anesthetic management to avoid injury to the cervical cord. The crux for upper airway management for cervical spine surgery is maintaining the neck in a neutral position with minimal neck movement during endotracheal intubation. Therefore, the conventional direct laryngoscopy (DL) can be unsuitable for securing the upper airway in cervical spine surgery, especially in cases of cervical spine instability and myelopathy. This review discu