  1. Increased airway reactivity in a neonatal mouse model of Continuous Positive Airway Pressure (CPAP)

    PubMed Central

    Mayer, Catherine A.; Martin, Richard J.; MacFarlane, Peter M.

    2015-01-01

    Background Continuous positive airway pressure (CPAP) is a primary form of respiratory support used in the intensive care of preterm infants, but its long-term effects on airway (AW) function are unknown. Methods We developed a neonatal mouse model of CPAP treatment to determine whether it modifies later AW reactivity. Un-anesthetized spontaneously breathing mice were fitted with a mask to deliver CPAP (6cmH2O, 3hrs/day) for 7 consecutive days starting at postnatal day 1. Airway reactivity to methacholine was assessed using the in vitro living lung slice preparation. Results One week of CPAP increased AW responsiveness to methacholine in male, but not female mice, compared to untreated control animals. The AW hyper-reactivity of male mice persisted for 2 weeks (at P21) after CPAP treatment ended. 4 days of CPAP, however, did not significantly increase AW reactivity. Females also exhibited AW hyper-reactivity at P21, suggesting a delayed response to early (7 days) CPAP treatment. The effects of 7 days of CPAP on hyper-reactivity to methacholine were unique to smaller AWs whereas larger ones were relatively unaffected. Conclusion These data may be important to our understanding of the potential long-term consequences of neonatal CPAP therapy used in the intensive care of preterm infants. PMID:25950451

  2. Motivational Interviewing (MINT) Improves Continuous Positive Airway Pressure (CPAP) Acceptance and Adherence: A Randomized Controlled Trial

    ERIC Educational Resources Information Center

    Olsen, Sara; Smith, Simon S.; Oei, Tian P. S.; Douglas, James

    2012-01-01

    Objective: Adherence to continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA) is poor. We assessed the effectiveness of a motivational interviewing intervention (motivational interview nurse therapy [MINT]) in addition to best practice standard care to improve acceptance and adherence to CPAP therapy in people with…

  3. Impact of Treatment with Continuous Positive Airway Pressure (CPAP) on Weight in Obstructive Sleep Apnea

    PubMed Central

    Quan, Stuart F.; Budhiraja, Rohit; Clarke, Denise P.; Goodwin, James L.; Gottlieb, Daniel J.; Nichols, Deborah A.; Simon, Richard D.; Smith, Terry W.; Walsh, James K.; Kushida, Clete A.

    2013-01-01

    Study Objective: To determine the impact of continuous positive airway pressure (CPAP) on weight change in persons with obstructive sleep apnea (OSA). Design, Setting, and Participants: The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blinded sham-controlled multicenter clinical trial conducted at 5 sites in the United States. Of 1,105 participants with an apnea hypopnea index ≥ 10 events/ hour initially randomized, 812 had body weight measured at baseline and after 6 months of study. Intervention: CPAP or Sham CPAP. Measurements: Body weight, height, hours of CPAP or Sham CPAP use, Epworth Sleepiness Scale score. Results: Participants randomized to CPAP gained 0.35 ± 5.01 kg, whereas those on Sham CPAP lost 0.70 ± 4.03 kg (mean ± SD, p = 0.001). Amount of weight gain with CPAP was related to hours of device adherence, with each hour per night of use predicting a 0.42 kg increase in weight. This association was not noted in the Sham CPAP group. CPAP participants who used their device ≥ 4 h per night on ≥ 70% of nights gained the most weight over 6 months in comparison to non-adherent CPAP participants (1.0 ± 5.3 vs. -0.3 ± 5.0 kg, p = 0.014). Conclusions: OSA patients using CPAP may gain a modest amount of weight with the greatest weight gain found in those most compliant with CPAP. Commentary: A commentary on this article appears in this issue on page 995. Citation: Quan SF; Budhiraja R; Clarke DP; Goodwin JL; Gottlieb DJ; Nichols DA; Simon RD; Smith TW; Walsh JK; Kushida CA. Impact of treatment with continuous positive airway pressure (CPAP) on weight in obstructive sleep apnea. J Clin Sleep Med 2013;9(10):989-993. PMID:24127141

  4. Oscillating Positive Airway Pressure Versus CPAP for the Treatment of Obstructive Sleep Apnea

    PubMed Central

    Haba-Rubio, José; Petitpierre, Nicolas Julien; Cornette, Françoise; Tobback, Nadia; Vat, Sopharat; Giallourou, Theresia; Al-Jumaily, Ahmed; Heinzer, Raphael

    2015-01-01

    Although continuous positive airway pressure (CPAP) is the most effective therapy for obstructive sleep apnea (OSA), it is not always well tolerated by the patients. Previous physiological studies showed that pressure oscillations applied to the pharynx could activate upper airway muscles, but it is not clear whether these pressure oscillations could be tolerated during sleep in OSA patients. The aim of this study was to assess the tolerance of oscillating positive airway pressure (O-PAP) (a CPAP device delivering high-frequency pressure oscillations to the upper airway) compared to CPAP. Fourteen OSA patients currently on CPAP [age 59.9 ± 10.1 years old, BMI 34.8 ± 7.2 kg/m2, initial apnea–hypopnea index (AHI): 58.7 ± 25.2 events/h] used O-PAP or CPAP on two consecutive nights under polysomnography, in a single-blind randomized crossover design to assess sleep quality. A subtherapeutic pressure (70% of the optimal titrated pressure) was applied in both conditions and the residual AHI with each technique was also compared. There was no difference in measured or perceived sleep quality between the two treatment modalities (sleep efficiency 90.0% versus 88.1%, p = 0.54). Despite the small sample, we also found a trend toward a decrease in residual respiratory events with O-PAP compared to CPAP (median AHI 14.3 versus 20.5/h, p = 0.194). The good tolerance of O-PAP and the positive trend toward a reduction in residual AHI should stimulate further research on the effects of O-PAP in OSA patients. PMID:26029694

  5. Effect of chronic continuous positive airway pressure (CPAP) therapy on upper airway size in patients with sleep apnoea/hypopnoea syndrome.

    PubMed Central

    Mortimore, I. L.; Kochhar, P.; Douglas, N. J.

    1996-01-01

    BACKGROUND: There is evidence to suggest that chronic continuous positive airway pressure (CPAP) therapy may produce reversible changes in upper airway morphology and function in patients with sleep apnoea/hypopnoea. This study was designed to examine the effect of chronic CPAP therapy on upper airway calibre. METHODS: Twenty four men with the sleep apnoea/hypopnoea syndrome (mean (SE) apnoea/hypopnoea index 37 (5)) underwent lateral cephalometry with measurement of posterior airway space performed before and at least three months after initiation of CPAP therapy. RESULTS: There was no weight change between the two assessments and mean CPAP use was 4.8 (0.4) hours per night. Posterior airway space (PAS) was measured in erect and supine postures. PAS supine increased with CPAP therapy from a mean (SE) of 11.8 (0.8) mm to 13.4 (0.8) mm, but PAS erect did not. Correlation of the change in PAS (dPAS) before and after CPAP therapy showed an increase with increasing CPAP compliance measured as machine run time both for dPAS supine (r = 0.68) and dPAS erect (r = 0.47). CONCLUSIONS: Patients with the sleep apnoea/hypopnoea syndrome regularly using CPAP for more than four hours per night all showed an increase in dPAS supine. The use of chronic CPAP increases PAS supine probably by a reduction in upper airway oedema, and the change in size is dependent on CPAP use. PMID:8711654

  6. A comparative study of continuous positive airway pressure (CPAP) and intermittent positive pressure ventilation (IPPV) in patients with flail chest

    PubMed Central

    Gunduz, M; Unlugenc, H; Ozalevli, M; Inanoglu, K; Akman, H

    2005-01-01

    Introduction: The role of non-invasive positive pressure ventilation delivered through a face mask in patients with flail chest is uncertain. We conducted a prospective, randomised study of continuous positive airway pressure (CPAP) given via a face mask to spontaneously breathing patients compared with intermittent positive pressure ventilation (IPPV) with endotracheal intubation (ETI) in 52 patients with flail chest who required mechanical ventilation. Method: The 52 mechanically ventilated patients were randomly divided into two treatment groups: the ET group (n = 27) received mechanical ventilation with ETI, whereas patients in the CPAP group (n = 25) received CPAP via a face mask with patient controlled analgesia (PCA). Major complications, arterial blood gas levels, length of intensive care unit (ICU) stay and ICU survival rate were recorded. Results: Nosocomial infection was diagnosed in 10 of 21 patients in the ET group, but only in 4 of 22 in the CPAP group (p = 0.001). Mean PO2 was significantly higher in the ET group in the first 2 days (p<0.05). There were no significant differences in length of ICU stay between groups. Twenty CPAP patients survived, but only 14 of 21 intubated patients who received IPPV (p<0.01). Conclusion: Non-invasive CPAP with PCA led to lower mortality and a lower nosocomial infection rate, but similar oxygenation and length of ICU stay. The study supports the application of CPAP at least as a first line of treatment for flail chest caused by blunt thoracic trauma. PMID:15843697

  7. Cerebral hemodynamics in patients with obstructive sleep apnea syndrome monitored with near-infrared spectroscopy (NIRS) during positive airways pressure (CPAP) therapy: a pilot study

    NASA Astrophysics Data System (ADS)

    Zhang, Zhongxing; Schneider, Maja; Laures, Marco; Fritschi, Ursula; Lehner, Isabella; Qi, Ming; Khatami, Ramin

    2014-03-01

    In obstructive sleep apnea syndrome (OSA) the periodic reduction or cessation of breathing due to narrowing or occlusion of the upper airway during sleep leads to daytime symptoms and increased cardiovascular risk, including stroke. The higher risk of stroke is related to the impairment in cerebral vascular autoregulation. Continuous positive airways pressure (CPAP) therapy at night is the most effective treatment for OSA. However, there is no suitable bedside monitoring method evaluating the treatment efficacy of CPAP therapy, especially to monitor the recovery of cerebral hemodynamics. NIRS is ideally suited for non-invasive monitoring the cerebral hemodynamics during sleep. In this study, we will for first time assess dynamic changes of cerebral hemodynamics during nocturnal CPAP therapy in 3 patients with OSA using NIRS. We found periodic oscillations in HbO2, HHb, tissue oxygenation index (TOI) and blood volume associated with periodic apnea events without CPAP in all OSA patients. These oscillations were gradually attenuated and finally eliminated with the stepwise increments of CPAP pressures. The oscillations were totally eliminated in blood volume earlier than in other hemodynamic parameters. These results suggested that 1) the cerebral hemodynamic oscillations induced by OSA events can effectively be attenuated by CPAP therapy, and 2) blood flow and blood volume recovered first during CPAP therapy, followed by the recovery of oxygen consumption. Our study suggested that NIRS is a useful tool to evaluate the efficacy of CPAP therapy in patients with OSA bedside and in real time.

  8. Lung clearance in children with Duchenne muscular dystrophy or spinal muscular atrophy with and without CPAP (continuous positive airway pressure).

    PubMed

    Klefbeck, B; Svartengren, K; Camner, P; Philipson, K; Svartengren, M; Sejersen, T; Mattsson, E

    2001-09-01

    Bronchiolar clearance was studied in 7 boys in the age range of 8 to 17 years, 6 with Duchenne muscular dystrophy (DMD) and 1 with spinal muscular atrophy type II (SMA-II). These boys had healthy lungs but a severely reduced muscular strength (wheelchair dependent). In 6 of the boys, clearance was studied twice, at one occasion as a control and at the other occasion following treatment with continuous positive airway pressure (CPAP). A control group of healthy adults was used. In the clearance examinations, 6-microm Teflon particles, labeled with III In was inhaled extremely slowly, 0.05 L/s. This gives a deposition mainly in the bronchioles. Lung retention was measured after 0,24,48, and 72 hours. A model for deposition of particles in the adult lung was scaled down to represent the children in this study. Deposition in various airway generations was calculated to be similar in children and adults. Also the measured retentions were similar in the boys and the adults. In the clearance experiments during CPAP treatment, there was a significantly lower retention after 72 hours (but not after 24 and 48 hours) than in the control experiments. Theresults indicate that a severe reduction of muscular strength, and thereby a reduction of mechanical movement of the lung, does not affect clearance from large and small airways. However, some effect of clearance from small airways cannot be excluded due to the short measuring period. The small but significant effect of the CPAP treatment might have potential clinical importance and suggest that bronchiolar clearance can be affected by some form of mechanical force. PMID:11558965

  9. Improving Heart rate variability in sleep apnea patients: differences in treatment with auto-titrating positive airway pressure (APAP) versus conventional CPAP.

    PubMed

    Karasulu, Levent; Epöztürk, Pinar Ozkan; Sökücü, Sinem Nedime; Dalar, Levent; Altin, Sedat

    2010-08-01

    The effect of positive airway pressure treatments in different modalities on the cardiovascular consequences of the disease in sleep apnea patients is still unclear. We aimed to compare auto-titrating positive airway pressure (APAP) and conventional continuous positive airway pressure (CPAP) in terms of improving heart rate variability (HRV) in obstructive sleep apnea patients. This was a prospective study done in a tertiary research hospital. All patients underwent a manual CPAP titration procedure to determine the optimal pressure that abolishes abnormal respiratory events. Then patients underwent two treatment nights, one under APAP mode and one under conventional CPAP mode with a 1-week interval. Forty newly diagnosed obstructive sleep apnea patients were enrolled in the study. We compared heart rate variability analysis parameters between the APAP night and the CPAP night. This final analysis included the data of 28 patients (M/F: 22/6; mean age = 46 +/- 10 years). Sleep characteristics were comparable between the two treatment nights, whereas all-night time domains of HRV analysis such as HF, nuLF, and LF/HF were different between APAP and CPAP nights (2.93 +/- 0.31 vs. 3.01 +/- 0.31; P = 0.041; 0.75 +/- 0.13 vs. 0.71 +/- 0.14; P = 0.027; and 4.37 +/- 3.24 vs. 3.56 +/- 2.07; P = 0.023, respectively). HRV analysis for individual sleep stages showed that Stage 2 LF, nuLF, nuHF, LF/HF parameters entirely improved under CPAP treatment whereas APAP treatment resulted in nonsignificant changes. These results suggest that despite comparable improvement in abnormal respiratory events with APAP or CPAP treatments, CPAP may be superior to APAP in terms of correcting cardiovascular alterations in sleep apnea patients.

  10. Impact of obstructive sleep apnea treatment by continuous positive airway pressure on cardiometabolic biomarkers: a systematic review from sham CPAP randomized controlled trials.

    PubMed

    Jullian-Desayes, Ingrid; Joyeux-Faure, Marie; Tamisier, Renaud; Launois, Sandrine; Borel, Anne-Laure; Levy, Patrick; Pepin, Jean-Louis

    2015-06-01

    Reducing cardiometabolic risk may represent an important target for effective obstructive sleep apnea (OSA) treatment. The impact of continuous positive airway pressure (CPAP), the first line therapy of OSA, on metabolic or inflammatory markers is still debated. A systematic literature search using several databases was performed. We provide a systematic analysis of randomized studies comparing therapeutic versus sham CPAP intervention and also include studies using a CPAP withdrawal design. We addressed the impact of CPAP on the following cardiometabolic biomarkers: 1) plasma and urine catecholamines and their metabolites that reflect sympathetic activity; 2) insulin resistance and lipid metabolism biomarkers; 3) oxidative stress, systemic and vascular inflammation biomarkers; 4) liver enzymes highlighting the association between OSA and nonalcoholic fatty liver disease (NAFLD); 5) coagulation biomarkers. The impact of CPAP on sympathetic activity is robust across studies and occurs rapidly. In contrast to sympathetic activity, the well-designed studies included in this review failed to demonstrate that CPAP alters metabolic or inflammatory markers in OSA. CPAP did not change glucose, lipids, insulin resistance levels or the ratio of patients with metabolic syndrome. In unselected OSA patients, it is not realistic to expect a clinically relevant decrease in cardiometabolic biomarkers with CPAP therapy.

  11. AB 83. EEG significance in polysomnography applying continuous positive airway pressure therapy (CPAP) in patients with Obstructive Sleep Apnea Syndrome

    PubMed Central

    Perantoni, Elena; Michailidis, Vasilis; Maglaveras, Nikos; Chouvarda, Ioanna; Tsara, Venetia

    2012-01-01

    Background The goal of this study is to explore the variations of EEG and evaluate the impact of its recording upon the process of discovering the optimal CPAP pressure, aiming at eliminating Obstructive Sleep Apnea episodes. Patients and methods 34 individuals diagnosed of OSAS by a polysomnography (PSG) were included in the study to whom during a second PSG a titration of CPAP was performed. The patients were divided in two groups depending on the Sleep Efficiency (SE) during the CPAP titration. The SE variation in relation to the initial PSG was further used to separate the patients into three sub-groups showing stable, improved or decreased SE. The examination of the EEG commences 5 minutes before and ends 5’ after finding the optimal CPAP pressure. For the analysis of the EEG Fractal dimension (FD) and Sample Entropy were used. Results No statistically important findings emerged comparing the eras before and after finding the optimal pressure in regards to the FD and its parameters in EEG. An important statistical difference between the 2 patients groups was found in the stages of sleep (S2 P=0.011, S3 P=0.029, REM P=0.026), the sleep total time (P=0.000), the latency of each stage (S2 P=0.036, S3 P=0.014). All groups showed a tendency of entropy decline after the optimal CPAP pressure, but it wasn’t statistically important. In the sub group of patients with diminished SE, a significant statistical difference was found between the various sleep stages that the optimal pressure was found, with the mean value of entropy (P=0.024) and its variation (P=0.001), as well as in the coefficient variance of the FD (P=0.040) and the mean FD values before (P=0.005) and after (P=0.05) the optimal CPAP pressure. Conclusions The changes in the EEG, as it appeared from the analysis of the various parameters using FD and Sample Entropy, are considered indirect evidence of the improvement of the EEG signal and therefore the microstructure of sleep. Further analysis is

  12. Nasal CPAP

    MedlinePlus

    ... stands for continuous positive airway pressure. CPAP pumps air under pressure into the airway of the lungs, keeping the ... the side of your bed. The machine pumps air under pressure through the hose and mask and into your ...

  13. Awake Measures of Nasal Resistance and Upper Airway Resistance on CPAP during Sleep

    PubMed Central

    Masdeu, Maria J.; Seelall, Vijay; Patel, Amit V.; Ayappa, Indu; Rapoport, David M.

    2011-01-01

    Study Objectives: Since on CPAP, the nose is the primary determinant of upper airway resistance, we assess utility of noninvasive measures of nasal resistance during wakefulness as a predictor of directly assessed upper airway resistance on CPAP during sleep in patients with obstructive sleep apnea/hypopnea syndrome. Methods: Patients with complaints of snoring and excessive daytime sleepiness were recruited. 14 subjects underwent daytime evaluations including clinical assessment, subjective questionnaires to assess nasal symptoms and evaluation of nasal resistance with acoustic rhinometry (AR) and active anterior rhinomanometry (RM) in the sitting and supine positions. Patients underwent nocturnal polysomnography on optimal CPAP with measurements of supraglottic pressure to evaluate upper airway resistance. Comparisons were made between nasal resistance using AR and RM during wakefulness, and between AR and RM awake and upper airway resistance during sleep. Results: Our study shows that measures of awake nasal resistance using AR and RM had little or no correlation to each other in the sitting position, whereas there was significant but weak correlation in the supine position. Upper airway resistance measured while on CPAP during sleep did not show significant relationships to any of the awake measures of nasal resistance (AR or RM). Conclusion: Awake measurements of nasal resistance do not seem to be predictive of upper airway resistance during sleep on CPAP. Citation: Masdeu MJ; Seelall V; Patel AV; Ayappa I; Rapoport DM. Awake Measures of Nasal Resistance and Upper Airway Resistance on CPAP during Sleep. J Clin Sleep Med 2011;7(1):31-40. PMID:21344056

  14. Five-Minute Awake Snoring Test for Determining CPAP Pressures (Five-Minute CPAP Test): A Pilot Study.

    PubMed

    Camacho, Macario; Ruoff, Chad M; Kawai, Makoto; Modi, Rahul; Arbee, Jabri; Hekmat, Anahid; Robertson, Matthew; Zaghi, Soroush; Certal, Victor; Capasso, Robson; Kushida, Clete A

    2016-01-01

    Objective. To develop a quick, simple, bedside test for determining continuous positive airway pressures (CPAP) for obstructive sleep apnea (OSA) patients. Study Design. Prospective case series at a tertiary medical center. Methods. The Five-Minute Awake Snoring Test for Determining CPAP (Five-Minute CPAP Test) was developed and tested. Patients wear a soft-gel nasal triangle mask while holding a tongue depressor with the wide section (1.75 cm) between the teeth. Fixed pressure nasal CPAP is applied while the patient simulates snoring at 4 centimeters of water pressure. The pressure is incrementally titrated up and then down to determine the lowest pressure at which the patient cannot snore (Quiet Pressure). Results. Overall, thirty-eight patients participated. All could simulate snoring. Correlation coefficients were statistically significant between Quiet Pressures and body mass index (r s = 0.60 [strong positive relationship], p = 0.0088), apnea-hypopnea index (r s = 0.49 [moderate positive relationship], p = 0.039), lowest oxygen saturation (r s = -0.47 [moderate negative relationship], p = 0.048), and oxygen desaturation index (r s = 0.62 [strong positive relationship], p = 0.0057). Conclusion. This pilot study introduces a new concept, which is the final product of over one year of exploration, development, and testing. Five-Minute CPAP Test is a quick, inexpensive, and safe bedside test based on supine awake simulated snoring with nasal CPAP.

  15. Five-Minute Awake Snoring Test for Determining CPAP Pressures (Five-Minute CPAP Test): A Pilot Study

    PubMed Central

    Camacho, Macario; Ruoff, Chad M.; Kawai, Makoto; Modi, Rahul; Arbee, Jabri; Hekmat, Anahid; Robertson, Matthew; Certal, Victor; Capasso, Robson; Kushida, Clete A.

    2016-01-01

    Objective. To develop a quick, simple, bedside test for determining continuous positive airway pressures (CPAP) for obstructive sleep apnea (OSA) patients. Study Design. Prospective case series at a tertiary medical center. Methods. The Five-Minute Awake Snoring Test for Determining CPAP (Five-Minute CPAP Test) was developed and tested. Patients wear a soft-gel nasal triangle mask while holding a tongue depressor with the wide section (1.75 cm) between the teeth. Fixed pressure nasal CPAP is applied while the patient simulates snoring at 4 centimeters of water pressure. The pressure is incrementally titrated up and then down to determine the lowest pressure at which the patient cannot snore (Quiet Pressure). Results. Overall, thirty-eight patients participated. All could simulate snoring. Correlation coefficients were statistically significant between Quiet Pressures and body mass index (rs = 0.60 [strong positive relationship], p = 0.0088), apnea-hypopnea index (rs = 0.49 [moderate positive relationship], p = 0.039), lowest oxygen saturation (rs = −0.47 [moderate negative relationship], p = 0.048), and oxygen desaturation index (rs = 0.62 [strong positive relationship], p = 0.0057). Conclusion. This pilot study introduces a new concept, which is the final product of over one year of exploration, development, and testing. Five-Minute CPAP Test is a quick, inexpensive, and safe bedside test based on supine awake simulated snoring with nasal CPAP. PMID:26881088

  16. Adherence to Continuous Positive Airway Pressure in Existing Users: Self-Efficacy Enhances the Association between Continuous Positive Airway Pressure and Adherence

    PubMed Central

    Dzierzewski, Joseph M.; Wallace, Douglas M.; Wohlgemuth, William K.

    2016-01-01

    Study Objectives: Obstructive sleep apnea-hypopnea syndrome (OSAHS) is a common sleep disorder associated with a myriad of sequelae. OSAHS is effectively treated with continuous positive airway pressure (CPAP) therapy. However, fewer than 50% of patients are compliant with their CPAP therapy prescriptions. The current study sought to explore an integrated, biopsychological approach to CPAP adherence among experienced CPAP users. Methods: We performed a retrospective, cross-sectional analysis of a cohort of veterans with a diagnosis of OSAHS (n = 191) who were prescribed CPAP therapy and returned for adherence download at the Miami VA Sleep Clinic. The relationships between biomedical characteristics (e.g., CPAP pressure, self-reported sleepiness, and change in sleep efficiency) and psychological factors (e.g., self-efficacy beliefs and psychological diagnoses) and objectively measured CPAP use were examined to determine whether psychological factors moderated the relationships between biomedical characteristics and CPAP adherence. Results: Hierarchical regression analyses predicting CPAP adherence (adjusting for time since CPAP prescription, age, education, prescribed CPAP pressure, daytime sleepiness, changes in sleep efficiency with CPAP, and psychiatric conditions) revealed the following: (1) CPAP self-efficacy and CPAP pressure were positively related to adherence, and (2) CPAP self-efficacy moderates the relationship between CPAP pressure and CPAP adherence. Conclusions: There was no relationship between CPAP pressure and adherence in individuals with low self-efficacy beliefs. However, for individuals with high self-efficacy beliefs, there was a significant positive relationship between CPAP pressure and adherence. Self-efficacy beliefs appear to be a prime target for focused interventions aimed at improving CPAP adherence among those individuals with higher pressure prescriptions. Citation: Dzierzewski JM, Wallace DM, Wohlgemuth WK. Adherence to continuous

  17. Nasal airway responses to nasal continuous positive airway pressure breathing: An in-vivo pilot study.

    PubMed

    White, David E; Bartley, Jim; Shakeel, Muhammad; Nates, Roy J; Hankin, Robin K S

    2016-06-14

    The nasal cycle, through variation in nasal airflow partitioning, allows the upper airway to accommodate the contrasting demands of air conditioning and removal of entrapped air contaminants. The purpose of this study was to investigate the influence of nasal continuous positive airway pressure (nCPAP) breathing has on both nasal airflow partitioning and nasal geometry. Using a custom-made nasal mask, twenty healthy participants had the airflow in each naris measured during normal nasal breathing followed by nCPAP breathing. Eight participants also underwent magnetic resonance imaging (MRI) of the nasal region during spontaneous nasal breathing, and then nCPAP breathing over a range of air pressures. During nCPAP breathing, a simultaneous reduction in airflow through the patent airway together with a corresponding increase in airway flow within the congested nasal airway were observed in sixteen of the twenty participants. Nasal airflow resistance is inversely proportional to airway cross-sectional area. MRI data analysis during nCPAP breathing confirmed airway cross-sectional area reduced along the patent airway while the congested airway experienced an increase in this parameter. During awake breathing, nCPAP disturbs the normal inter-nasal airflow partitioning. This could partially explain the adverse nasal drying symptoms frequently reported by many users of this therapy. PMID:27173595

  18. The influence of multilevel upper airway surgery on CPAP tolerance in non-responders to obstructive sleep apnea surgery.

    PubMed

    Azbay, Sule; Bostanci, Asli; Aysun, Yasin; Turhan, Murat

    2016-09-01

    The aim of this study was to evaluate the influence of multilevel upper airway surgery on subsequent continuous positive airway pressure (CPAP) use and tolerance in patients with moderate to severe obstructive sleep apnea (OSA). The study cohort enrolled 67 consecutive patients, who underwent septoplasty plus modified uvulopharyngopalatoplasty (mUPPP) with or without modified tongue base suspension (mTBS) due to CPAP intolerance, and who had residual OSA requiring CPAP therapy [non-responders to surgery, apnea-hypopnea index (AHI) >15 events/h] that had been confirmed by control polysomnography at the sixth month postoperatively. A questionnaire including questions on postoperative CPAP use, problems faced during CPAP use after the surgery, change in OSA symptoms, and satisfaction with the surgery was designed, and filled through interviews. Seventeen (25.4 %) patients had septoplasty plus mUPPP and 50 (74.6 %) had septoplasty plus mUPPP combined with mTBS. Postoperatively, mean AHI (45.00 ± 19.76 vs. 36.60 ± 18.34), Epworth sleepiness scale (ESS) score (18.00 ± 4.45 vs. 13.00 ± 4.72), oxygen desaturation index (ODI) (48.98 ± 16.73 vs. 37.81 ± 17.03), and optimal CPAP level (11.80 ± 1.40 vs. 8.96 ± 1.20) were decreased (p < 0.001 for all parameters). Fifty-nine percent of patients reported that they fairly satisfied with the surgery and 49.2 % reported that their symptoms were completely resolved. While none of the cases could tolerate CPAP before surgery, almost half (47.8 %) of the cases used CPAP without problems postoperatively. Postoperative CPAP users had significantly higher postoperative AHI (p = 0.001), supine AHI (p = 0.009), ESS (p = 0.019), and ODI (p = 0.014), and significantly lower postoperative minimum O2 saturation (p = 0.001) compared with non-users. Multilevel upper airway surgery with less invasive techniques may improve CPAP tolerance in well-selected patients.

  19. CPAP Treatment Supported by Telemedicine Does Not Improve Blood Pressure in High Cardiovascular Risk OSA Patients: A Randomized, Controlled Trial

    PubMed Central

    Mendelson, Monique; Vivodtzev, Isabelle; Tamisier, Renaud; Laplaud, David; Dias-Domingos, Sonia; Baguet, Jean-Philippe; Moreau, Laurent; Koltes, Christian; Chavez, Léonidas; De Lamberterie, Gilles; Herengt, Frédéric; Levy, Patrick; Flore, Patrice; Pépin, Jean-Louis

    2014-01-01

    Study Objectives: Obstructive sleep apnea (OSA) has been associated with hypertension, which is one of the intermediary mechanisms leading to increased cardiovascular morbidity. This study aimed at evaluating the effects of a combination of continuous positive airway pressure (CPAP) and telemedicine support on blood pressure (BP) reduction in high cardiovascular risk OSA patients. Design: A multi-center randomized controlled trial that compared standard CPAP care and CPAP care and a telemedicine intervention. Setting: Sleep clinics in France. Patients or Participants: 107 adult (18-65 years old) OSA patients (AHI > 15 events/h) with a high cardiovascular risk (cardiovascular SCORE > 5% or secondary prevention). Interventions: Patients were randomized to either standard care CPAP (n = 53) or CPAP and telemedicine (n = 54). Patients assigned to telemedicine were equipped with a smartphone for uploading BP measurements, CPAP adherence, sleepiness, and quality of life data; in return, they received pictograms containing health-related messages. Measurements: The main outcome was home self-measured BP and secondary outcomes were cardiovascular risk evolution, objective physical activity, CPAP adherence, sleepiness and quality of life. Results: Self-measured BP did not improve in either group (telemedicine or standard care). Patients in primary prevention showed greater BP reduction with CPAP treatment than those in secondary prevention. Conclusions: CPAP treatment supported by telemedicine alone did not improve blood pressure and cardiovascular risk in high cardiovascular risk OSA patients. This study emphasizes the need for diet and physical activity training programs in addition to CPAP when aiming at decreasing cardiometabolic risk factors in these patients. Clinical Trials Registration: ClinicalTrials.gov identifier: NCT01226641. Citation: Mendelson M, Vivodtzev I, Tamisier R, Laplaud D, Dias-Domingos S, Baguet JP, Moreau L, Koltes C, Chavez L, De Lamberterie G

  20. [Continuous positive airways pressure treatment for obstructive sleep apnoea].

    PubMed

    Antone, E; Gilbert, M; Bironneau, V; Meurice, J C

    2015-04-01

    Continuous positive airway pressure (CPAP) still remains the most frequently used and the most efficient treatment for obstructive sleep apnea syndrome. However, its efficiency is conditioned by healthcare quality depending on many factors such as medical specificities of the patients as well as the severity of sleep-related breathing disorders. In order to optimize CPAP efficiency, it is necessary to be aware of the functional abilities of the different devices, and to perform a close monitoring of the patients, particularly during the first weeks of treatment, by maximally using the data provided by the CPAP apparatus. Some questions remain unsolved, such as the impact of nasal CPAP on glucose metabolism or cardiovascular prognosis. Furthermore, the strategy of CPAP use should be improved according to future results of studies dedicated to the interest of home telemonitoring and taking into account the validated mode of CPAP initiation. PMID:25823935

  1. Continuous positive airway pressure therapy: new generations.

    PubMed

    Garvey, John F; McNicholas, Walter T

    2010-02-01

    Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS). However, CPAP is not tolerated by all patients with OSAS and alternative modes of pressure delivery have been developed to overcome pressure intolerance, thereby improving patient comfort and adherence. Auto-adjustable positive airway pressure (APAP) devices may be utilised for the long-term management of OSAS and may also assist in the initial diagnosis of OSAS and titration of conventional CPAP therapy. Newer modalities such as C-Flex and A-Flex also show promise as treatment options in the future. However, the evidence supporting the use of these alternative modalities remains scant, in particular with regard to long-term cardiovascular outcomes. In addition, not all APAP devices use the same technological algorithms and data supporting individual APAP devices cannot be extrapolated to support all. Further studies are required to validate the roles of APAP, C-Flex and A-Flex. In the interim, standard CPAP therapy should continue as the mainstay of OSAS management. PMID:20308751

  2. Control system design for a continuous positive airway pressure ventilator

    PubMed Central

    2012-01-01

    Continuous Positive Airway Pressure (CPAP) ventilation remains a mainstay treatment for obstructive sleep apnea syndrome (OSAS). Good pressure stability and pressure reduction during exhalation are of major importance to ensure clinical efficacy and comfort of CPAP therapy. In this study an experimental CPAP ventilator was constructed using an application-specific CPAP blower/motor assembly and a microprocessor. To minimize pressure variations caused by spontaneous breathing as well as the uncomfortable feeling of exhaling against positive pressure, we developed a composite control approach including the feed forward compensator and feedback proportional-integral-derivative (PID) compensator to regulate the pressure delivered to OSAS patients. The Ziegler and Nichols method was used to tune PID controller parameters. And then we used a gas flow analyzer (VT PLUS HF) to test pressure curves, flow curves and pressure-volume loops for the proposed CPAP ventilator. The results showed that it met technical criteria for sleep apnea breathing therapy equipment. Finally, the study made a quantitative comparison of pressure stability between the experimental CPAP ventilator and commercially available CPAP devices. PMID:22296604

  3. Strategies for the prevention of continuous positive airway pressure failure.

    PubMed

    Sahni, Rakesh; Schiaratura, Maria; Polin, Richard A

    2016-06-01

    Progress in neonatal intensive care is closely linked to improvements in the management of respiratory failure in preterm infants. Current modalities of respiratory support range from the more benign continuous positive airway pressure (CPAP) to various modes of mechanical ventilation. Data from recent randomized control trials suggest that the use of nasal (n)CPAP as the initial mode of respiratory support in critically ill very low birth weight infants is associated with a lower incidence of chronic lung disease. The practice of early initiation of nasal-prong CPAP in all spontaneously breathing infants at Columbia University has resulted in very low rates of chronic lung disease for decades. Many institutions have attempted to replicate the practices and results at Columbia University. However, success rates with nCPAP are highly variable, which may in part be attributable to how well it is utilized. With recent renewed interest in non-invasive respiratory support, particularly bubble nCPAP, it is essential to evaluate strategies for the prevention of CPAP failure. This review discusses strategies that address these issues and shares the practical aspects for replicating success with bubble nCPAP. In addition, it reviews desirable features, major components, and physiological consequences of various bubble CPAP systems along with clinical experience of CPAP use. PMID:26936186

  4. Adherence to Continuous Positive Airway Pressure Treatment for Obstructive Sleep Apnea: Implications for Future Interventions

    PubMed Central

    Weaver, Terri E.; Sawyer, Amy M.

    2010-01-01

    Adherence to continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) is a critical problem with adherence rates ranging from 30–60%. Poor adherence to CPAP is widely recognized as a significant limiting factor in treating OSA, reducing the overall effectiveness of the treatment and leaving many OSA patients at heightened risk for comorbid conditions, impaired function and quality of life. The extant literature examining adherence to CPAP provides critical insight to measuring adherence outcomes, defining optimal adherence levels, and predicting CPAP adherence. This research has revealed salient factors that are associated with or predict CPAP adherence and may guide the development of interventions to promote CPAP adherence. Over the past 10 years, intervention studies to promote CPAP adherence have incorporated a multitude of strategies including education, support, cognitive behavioral approaches, and mixed strategies. This review of the current state of science of CPAP adherence will (1) synthesize the extant literature with regard to measuring, defining, and predicting CPAP adherence, (2) review published intervention studies aimed at promoting CPAP adherence, and (3) suggest directions for future empiric study of adherence to CPAP that will have implications for translational science. Our current understanding of CPAP adherence suggests that adherence is a multi-factorial, complex clinical problem that requires similarly designed approaches to effectively address poor CPAP adherence in the OSA population. PMID:20308750

  5. Inferior Turbinate Size and CPAP Titration Based Treatment Pressures: No Association Found among Patients Who Have Not Had Nasal Surgery

    PubMed Central

    Camacho, Macario; Zaghi, Soroush; Tran, Daniel; Song, Sungjin A.; Chang, Edward T.; Certal, Victor

    2016-01-01

    Objective. To evaluate the effect of turbinate sizes on the titrated continuous positive airway pressure (CPAP) therapeutic treatment pressures for patients with obstructive sleep apnea (OSA) who have not had nasal surgery. Study Design. Retrospective case series. Methods. A chart review was performed for 250 consecutive patients. Results. 45 patients met inclusion criteria. The mean ± standard deviation (M ± SD) for age was 54.6 ± 22.4 years and for body mass index was 28.5 ± 5.9 kg/m2. The Spearman's rank correlation coefficient (rs) between CPAP therapeutic treatment pressures and several variables were calculated and were weakly correlated (age rs = 0.29, nasal obstruction rs = −0.30), moderately correlated (body mass index rs = 0.42 and lowest oxygen saturation rs = −0.47), or strongly correlated (apnea-hypopnea index rs = 0.60 and oxygen desaturation index (rs = 0.62)). No statistical significance was found with one-way analysis of variance (ANOVA) between CPAP therapeutic treatment pressures and inferior turbinate size (right turbinates p value = 0.2012, left turbinate p value = 0.3064), nasal septal deviation (p value = 0.4979), or mask type (p value = 0.5136). Conclusion. In this study, CPAP titration based therapeutic treatment pressures were not found to be associated with inferior turbinate sizes; however, the CPAP therapeutic treatment pressures were strongly correlated with apnea-hypopnea index and oxygen desaturation index. PMID:26904126

  6. [Automatic positive airway pressure in titration and treatment of the obstructive sleep apnea syndrome].

    PubMed

    Randerath, W J

    2007-04-01

    Although continuous airway pressure therapy (CPAP) represents the standard treatment for obstructive sleep apnea syndrome (OSAS) auto-adjusting CPAP (APAP) devices were developed which adapt the treatment pressure to the actual requirement of the patients. The aim of automatic CPAP therapy is to improve the patients' acceptance of positive pressure treatment. The devices react to respiratory flow, flattening of the inspiratory flow contour, snoring, generator speed or the upper airway impedance. In recent years several studies showed that auto CPAP effectively treats respiratory disturbances, improves sleep profile and the self-assessment of the patients equally as good as the gold standard constant CPAP. Moreover, APAP reduces the treatment pressure substantially. Although an improvement of the patient's compliance has not consistently been proven, most patients prefer APAP versus constant CPAP. APAP devices use different algorithms depending on the primary purpose of the application. Therefore, a clear distinction between automatic titration and treatment is of major relevance. While titration devices aim at the finding of one single pressure which is fixed to a constant CPAP device, automatic treatment means the chronic use of APAP at home for optimal adaptation of the treatment pressure to the actual requirements of the patient. A high constant CPAP level, huge pressure variability, insufficient compliance with constant CPAP may be indications for APAP treatment. The main reason for automatic titration is the standardisation of the initiation process. PMID:17455137

  7. Bubble–CPAP vs. Ventilatory–CPAP in Preterm Infants with Respiratory Distress

    PubMed Central

    Bahman-Bijari, Bahareh; Malekiyan, Arash; Niknafs, Pedram; Baneshi, Mohammad-Reza

    2011-01-01

    Objective Application of Continuous Positive Airway Pressure (CPAP) in neonate with respiratory distress is associated with reduction of respiratory failure, reduced complications and mortality. Bubble CPAP (B-CPAP) and ventilator-derived CPAP (V-CPAP) are two most popular CPAP modes. We aimed to determine whether B-CPAP and V-CPAP would have different survival rate and possible complications. Methods This prospective clinical trial was performed on 50 preterm neonates weighing 1000-2000 gr who were admitted to the neonatal intensive care unit of Afzalipoor Hospital because of respiratory distress between June 2009 and May 2010. Patients were randomly allocated into treatment groups using minimization technique. Survival analysis was applied to estimate and compare survival rates. Duration of oxygen therapy, hospital stay as well as hospitalization costs were compared using independent sample t-test. Findings Estimated survival rates at 24 hours in B-CPAP and V-CPAP groups were 100% and 77% respectively. Corresponding figures at 48 hours were 100% and 71%. In addition the hospitalization cost in V-CPAP group was significantly higher than in B-CPAP group. Conclusion According to our results, B-CPAP was effective in the treatment of neonates who were suffering from respiratory distress and reduced the duration of hospital stay. In addition to mentioned benefits, its low cost may be the reason to use B-CPAP broadly compared with V-CPAP. PMID:23056781

  8. Established vascular effects of continuous positive airway pressure therapy in patients with obstructive sleep apnoea—an update

    PubMed Central

    Wons, Annette Marie

    2015-01-01

    The aim of this review was to summarize the current data from randomised controlled trials (RCTs) on vascular effects of continuous positive airway pressure (CPAP) therapy in patients with obstructive sleep apnoea (OSA). There is good evidence from RCTs that CPAP lowers blood pressure (BP) to a clinically significant amount. The effect seems to be dependent on the hours of nightly CPAP usage. Data from RCTs have also proven a beneficial effect of CPAP on measures of vascular function such as endothelial function and arterial stiffness. However, there is still a lack of evidence from RCTs proving that CPAP reduces vascular events and mortality. PMID:26101649

  9. Established vascular effects of continuous positive airway pressure therapy in patients with obstructive sleep apnoea-an update.

    PubMed

    Wons, Annette Marie; Kohler, Malcolm

    2015-05-01

    The aim of this review was to summarize the current data from randomised controlled trials (RCTs) on vascular effects of continuous positive airway pressure (CPAP) therapy in patients with obstructive sleep apnoea (OSA). There is good evidence from RCTs that CPAP lowers blood pressure (BP) to a clinically significant amount. The effect seems to be dependent on the hours of nightly CPAP usage. Data from RCTs have also proven a beneficial effect of CPAP on measures of vascular function such as endothelial function and arterial stiffness. However, there is still a lack of evidence from RCTs proving that CPAP reduces vascular events and mortality. PMID:26101649

  10. Is continuous positive airway pressure necessarily an everyday therapy in patients with obstructive sleep apnoea?

    PubMed

    Rossi, Valentina A; Schwarz, Esther I; Bloch, Konrad E; Stradling, John R; Kohler, Malcolm

    2014-05-01

    There are limited data on the evolution of obstructive sleep apnoea (OSA) during continuous positive airway pressure (CPAP) therapy and whether this treatment is required every night. 125 OSA patients with an original oxygen desaturation index (ODI) >10 events per hour, established on CPAP, were asked to withdraw CPAP for four nights and performed ambulatory nocturnal pulse oximetry on the fourth night of CPAP withdrawal. An ODI >10 events per hour during pulse oximetry was considered to indicate persistent OSA. Patients not experiencing recurrence of OSA underwent repeat ambulatory pulse oximetry after a further 2-week period off CPAP. In 71% of the patients, OSA recurred after four nights of CPAP withdrawal (group 1); thus, OSA did not recur in 29% (group 2). 55% of group 2 had an ODI >10 events per hour after 2 weeks off CPAP; thus, 45% remained without a recurrence. In multivariate analysis, higher original ODI, longer duration of CPAP therapy, current smoking status and larger neck circumference were independently associated with a higher ODI after four nights of CPAP withdrawal (all p<0.05). Following CPAP withdrawal, a third of CPAP-treated patients do not experience significant recurrence of oxygen desaturations after 4 days and ∼10% do not after 2 weeks. Thus, a significant proportion of patients may be able to stop CPAP for short periods.

  11. A simple circuit to deliver bubbling CPAP.

    PubMed

    Kaur, Charanjit; Sema, Akatoli; Beri, Rajbir S; Puliyel, Jacob M

    2008-04-01

    Nasal continuous positive airway pressure (CPAP), especially bubbling CPAP, is known to reduce the need for more invasive ventilation. We here describe a circuit that can deliver bubbling CPAP in resource poor settings. We describe how the oxygen concentration can be altered from 98% to 21% oxygen using this system. Addition of a humidifier in the circuit has the effect of reducing the oxygen concentration by 1 to 5%. The cost of putting together the system is approximately Rs 5000.

  12. The value of auto-adjustable CPAP devices in pressure titration and treatment of patients with obstructive sleep apnea syndrome.

    PubMed

    Hertegonne, Katrien; Bauters, Fré

    2010-04-01

    In moderate to severe obstructive sleep apnea syndrome (OSAS), the use of Continuous Positive Airway Pressure (CPAP) is the gold standard therapy. In the last decade, new technologies such as auto-adjustable CPAP (APAP) have been promoted as having an added advantage over CPAP, because of their ability to adapt the pressure level to the patient's need at all times. This could logically result in the deliverance of lower pressures, which was hypothesized to improve patient acceptance and compliance for therapy. Several clinical trials have been performed with APAP in different modalities, as a titration tool in attended or unattended conditions, or as a treatment device for chronic use. Comparison of these trials is challenging, since APAP technology is evolving promptly and devices differ not only in how sleep-disordered breathing is detected, but also in how the operational algorithm responds accordingly. Although the question remains whether proof has yet been delivered of the superiority of this technology over CPAP, there is a tendency to accept it as common standard practice in OSAS titration and treatment. This review will bring available evidence on this subject into perspective. PMID:19716321

  13. Use of nasal continuous positive airway pressure during neonatal transfers

    PubMed Central

    Bomont, R K; Cheema, I U

    2006-01-01

    Objective To review all cases in which nasal continuous positive airway pressure (CPAP) was used as a means of respiratory support during land based ambulance transfers by a regional neonatal transport service. Design Retrospective study based on review of transport records. Results A total of 1175 transfer requests were received over the 21 month period. The infant in 163 of these cases was receiving nasal CPAP. Ninety two referrals were accepted by the doctor/nurse practitioner led team. Of these, 84 were transported while receiving nasal CPAP. Intervention during transport was required in three of these cases. Fifty five referrals were accepted by the nurse led team. Of these, 16 were transported while receiving nasal CPAP. Intervention was required in two cases. Conclusion There is a small but significant demand for transferring infants who are receiving nasal CPAP. Nasal CPAP appears to be a safe method of respiratory support for a carefully selected group of infants during land based ambulance transfers. PMID:16204357

  14. Comparison between automatic and fixed positive airway pressure therapy in the home.

    PubMed

    Massie, Clifford A; McArdle, Nigel; Hart, Robert W; Schmidt-Nowara, Wolfgang W; Lankford, Alan; Hudgel, David W; Gordon, Nancy; Douglas, Neil J

    2003-01-01

    We tested the hypothesis that continuous positive airway pressure (CPAP) use and outcomes can be improved by an autotitrating CPAP device in patients with obstructive sleep apnea-hypopnea syndrome (OSAHS) who require higher CPAP (10 cm H2O or more). In this multisite randomized single-blind cross-over study, 44 patients (mean age, 49 +/- 10 years) were randomized to 6 weeks at laboratory-determined fixed pressure and 6 weeks on autotitrating CPAP. Average nightly use was greater in automatic mode (306 versus 271 minutes, p = 0.005); median and 95th centile pressures in automatic mode were lower (p < 0.002). Automatic CPAP resulted in better SF-36 Vitality scores (65 +/- 20 versus 58 +/- 23, p < 0.05) and mental health scores (80 +/- 14 versus 75 +/- 18, p < 0.05), but no significant difference in Epworth score (p = 0.065). During automatic therapy, patients reported more restful sleep, better quality sleep, less discomfort from pressure, and less trouble getting to sleep for both the first week of therapy and for the averaged scores for Weeks 2-6 (all p values < 0.006). Patients who require higher fixed CPAP use autotitrating CPAP more and report greater benefit from this therapy.

  15. Do turbines with servo-controlled speed improve continuous positive airway pressure generation?

    PubMed

    Lofaso, F; Heyer, L; Leroy, A; Lorino, H; Harf, A; Isabey, D

    1994-11-01

    Nasal continuous positive airway pressure (CPAP) devices with a servo-mechanism to control pressure have recently been developed. We evaluated six such devices and three conventional systems in terms of effectiveness in maintaining constant pressure. Machines were tested with pressure levels of 5, 10 and 15 cmH2O. Dynamic behaviour was evaluated: 1) by calculating the imposed work of breathing during simulated breath generated by a sinusoidal pump; and 2) by following the fall in pressure after a transient flow of 1 l.s-1. Quasi-static behaviour was evaluated by simulating a predetermined air leak. Under dynamic conditions, work of breathing was lowest with one conventional nasal CPAP device and three servo-controlled nasal CPAP devices; whereas, the highest levels of work of breathing were recorded with two servo-controlled nasal CPAP devices. The pressure-time response to a transient flow yielded similar results, with a significant inverse correlation between pressure values observed after 300 ms and imposed work of breathing during simulated breathing (r = -0.91). Under quasi-static conditions, microprocessor servo-controlled devices exhibited the best performance. These results suggest that microprocessor servo-controlled nasal CPAP devices are not always the best systems for maintaining constant airway pressure in dynamic situations. However, they are more effective in ensuring maintenance of the desired pressure in the event of an air leak at the mask. PMID:7875284

  16. Impact of Randomization, Clinic Visits, and Medical and Psychiatric Cormorbidities on Continuous Positive Airway Pressure Adherence in Obstructive Sleep Apnea

    PubMed Central

    Budhiraja, Rohit; Kushida, Clete A.; Nichols, Deborah A.; Walsh, James K.; Simon, Richard D.; Gottlieb, Daniel J.; Quan, Stuart F.

    2016-01-01

    Study Objectives: To evaluate factors associated with continuous positive airway pressure (CPAP) adherence in patients with obstructive sleep apnea (OSA) in the Apnea Positive Pressure Long-term Efficacy Study (APPLES) cohort. Methods: The data from a prospective 6-mo multicenter randomized controlled trial with 558 subjects randomized to active CPAP and 547 to sham CPAP were analyzed to assess adherence to CPAP during first 2 mo (early period) and during months 5-6 (late period). Results: Participants randomized to active CPAP had higher hours of nightly adherence compared to the sham CPAP group at both 2 (4.9 ± 2.0 h versus 4.07 ± 2.14 h, p < 0.001) and 6 mo (4.70 ± 2.08 h versus 3.41 ± 2.19 h, p < 0.001). Those assigned to sham CPAP were more likely to correctly identify their treatment group (70.0% versus 55.2%, p < 0.001). Irrespective of treatment group assignment, those who believed they were receiving active CPAP had higher hours of adherence than those who thought they were in the sham CPAP group at both 2 mo (4.91 ± 2.01 versus 4.17 ± 2.17, p < 0.001) and 6 mo (4.65 ± 2.10 versus 3.65 ± 2.22, p < 0.001). Among those randomized to active CPAP, older age was significantly related to CPAP use > 4 h per night. Presence of cardiovascular disorders was associated with higher hours of CPAP use, whereas presence of anxiety was associated with a trend toward lower hours of CPAP use. Presence of nasal congestion was associated with a decrease in mean daily CPAP use between the early and the late adherence period. The adherence during the week prior to a clinic visit was higher than the average adherence during the 2-mo period prior to the visit. Conclusions: Randomization to active therapy, belief that one is in the active treatment group, older age, and possibly presence of cardiovascular disorders are positively linked to CPAP adherence. Nasal congestion and anxiety are negatively associated with CPAP adherence. CPAP nightly usage increases as clinic

  17. Effect of Continuous Positive Airway Pressure on Airway Inflammation and Oxidative Stress in Patients with Obstructive Sleep Apnea

    PubMed Central

    Tichanon, Promsrisuk; Sopida, Santamit; Orapin, Pasurivong; Watchara, Boonsawat; Banjamas, Intarapoka

    2016-01-01

    Background. Airway inflammation and oxidative stress may be linked in obstructive sleep apnea (OSA) patients. We determined the effectiveness of continuous positive airway pressure (CPAP) therapy in reducing fractional exhaled nitric oxide (FeNO) and malondialdehyde (MDA) levels in OSA patients. Methods. Thirteen patients with OSA and 13 normal controls were recruited. FeNO and MDA levels were measured in the controls and in OSA patients before and after three months of CPAP therapy. Results. FeNO and MDA levels were higher in the patients compared to the age and gender matched controls (FeNO: 25.9 ± 5.0 versus 17.5 ± 5.9 ppb, P < 0.001; MDA: 14.6 ± 7.8 versus 2.1 ± 0.3 μmol/L, P < 0.001). FeNO and MDA levels were lower post-CPAP compared to pre-CPAP (FeNO: 25.9 ± 5.0 versus 17.0 ± 2.3 ppb, P < 0.001; MDA: 14.6 ± 7.8 versus 10.0 ± 6.4 μmol/L, P < 0.01). Apnea-hypopnea index (15.9 ± 6.6 versus 4.1 ± 2.1/h, P < 0.001) and mean arterial pressure (P < 0.01) decreased following CPAP treatment. Daytime mean SpO2 (P < 0.05) increased. Conclusion. Our study demonstrates that CPAP therapy yields clinical benefits by reducing upper airway inflammation and oxidative stress in OSA patients. PMID:27445526

  18. Effect of Continuous Positive Airway Pressure on Airway Inflammation and Oxidative Stress in Patients with Obstructive Sleep Apnea.

    PubMed

    Tichanon, Promsrisuk; Wilaiwan, Khrisanapant; Sopida, Santamit; Orapin, Pasurivong; Watchara, Boonsawat; Banjamas, Intarapoka

    2016-01-01

    Background. Airway inflammation and oxidative stress may be linked in obstructive sleep apnea (OSA) patients. We determined the effectiveness of continuous positive airway pressure (CPAP) therapy in reducing fractional exhaled nitric oxide (FeNO) and malondialdehyde (MDA) levels in OSA patients. Methods. Thirteen patients with OSA and 13 normal controls were recruited. FeNO and MDA levels were measured in the controls and in OSA patients before and after three months of CPAP therapy. Results. FeNO and MDA levels were higher in the patients compared to the age and gender matched controls (FeNO: 25.9 ± 5.0 versus 17.5 ± 5.9 ppb, P < 0.001; MDA: 14.6 ± 7.8 versus 2.1 ± 0.3 μmol/L, P < 0.001). FeNO and MDA levels were lower post-CPAP compared to pre-CPAP (FeNO: 25.9 ± 5.0 versus 17.0 ± 2.3 ppb, P < 0.001; MDA: 14.6 ± 7.8 versus 10.0 ± 6.4 μmol/L, P < 0.01). Apnea-hypopnea index (15.9 ± 6.6 versus 4.1 ± 2.1/h, P < 0.001) and mean arterial pressure (P < 0.01) decreased following CPAP treatment. Daytime mean SpO2 (P < 0.05) increased. Conclusion. Our study demonstrates that CPAP therapy yields clinical benefits by reducing upper airway inflammation and oxidative stress in OSA patients.

  19. Airway obstruction with cricoid pressure.

    PubMed

    Hartsilver, E L; Vanner, R G

    2000-03-01

    Cricoid pressure may cause airway obstruction. We investigated whether this is related to the force applied and to the technique of application. We recorded expired tidal volumes and inflation pressures during ventilation via a face-mask and oral airway in 52 female patients who were anaesthetised and about to undergo elective surgery. An inspired tidal volume of 900 ml was delivered using a ventilator. Ventilation was assessed under five different conditions: no cricoid pressure, backwards cricoid pressure applied with a force of 30 N, cricoid pressure applied in an upward and backward direction with a force of 30 N, backwards cricoid pressure with a force of 44 N and through a tracheal tube. An expired tidal volume of < 200 ml was taken to indicate airway obstruction. Airway obstruction did not occur without cricoid pressure, but did occur in one patient (2%) with cricoid pressure at 30 N, in 29 patients (56%) with 30 N applied in an upward and backward direction and in 18 (35%) patients with cricoid pressure at 44 N. Cricoid pressure applied with a force of 44 N can cause airway obstruction but if cricoid pressure is applied with a force of 30 N, airway obstruction occurs less frequently (p = 0.0001) unless the force is applied in an upward and backward direction.

  20. Airway obstruction with cricoid pressure.

    PubMed

    Hartsilver, E L; Vanner, R G

    2000-03-01

    Cricoid pressure may cause airway obstruction. We investigated whether this is related to the force applied and to the technique of application. We recorded expired tidal volumes and inflation pressures during ventilation via a face-mask and oral airway in 52 female patients who were anaesthetised and about to undergo elective surgery. An inspired tidal volume of 900 ml was delivered using a ventilator. Ventilation was assessed under five different conditions: no cricoid pressure, backwards cricoid pressure applied with a force of 30 N, cricoid pressure applied in an upward and backward direction with a force of 30 N, backwards cricoid pressure with a force of 44 N and through a tracheal tube. An expired tidal volume of < 200 ml was taken to indicate airway obstruction. Airway obstruction did not occur without cricoid pressure, but did occur in one patient (2%) with cricoid pressure at 30 N, in 29 patients (56%) with 30 N applied in an upward and backward direction and in 18 (35%) patients with cricoid pressure at 44 N. Cricoid pressure applied with a force of 44 N can cause airway obstruction but if cricoid pressure is applied with a force of 30 N, airway obstruction occurs less frequently (p = 0.0001) unless the force is applied in an upward and backward direction. PMID:10671836

  1. Reversibility of albuminuria and continuous positive airway pressure compliance in patients of obstructive sleep apnea syndrome.

    PubMed

    Chen, Ning-Hung; Chou, Yu-Ting; Lee, Pei-Hsien; Lin, Shih-Wei; Chuang, Li-Pang; Lin, Yu-Sheng; Yang, Cheng-Ta

    2016-06-01

    A positive correlation between albuminuria and severity of obstructive sleep apnea syndrome (OSAS) has been demonstrated, as indexed by urine albumin-to-creatinine ratios (UACRs). However, the effect of continuous positive airway pressure (CPAP) treatment on albuminuria in OSAS patients has not been established.Sixty subjects, with apnea-hypopnea indices >15 events per hour and no other diagnoses associated with albuminuria, underwent overnight polysomnography for sleep apnea and were examined for UACR at baseline and after 6 months of CPAP therapy. CPAP compliance rates were also recorded.Significant improvement in UACR was found in OSAS patients with good compliance to CPAP treatment after 6 months of therapy (baseline vs 6-month follow-up, 32.0 ± 9.5 vs 19.2 ± 6.5 mg/g, respectively, P = 0.007), whereas slight worsening in UACRs was noted in patients with poor compliance to CPAP treatment (baseline vs 6-month follow-up, respectively, 16.7 ± 4.4 vs 19.1 ± 6.3 mg/g, respectively, P = 0.39). Change in UACR was significant between poor compliance versus good compliance groups (2.4 ± 2.7 vs -12.8 ± 4.4 mg/g, respectively, t = 2.9, P = 0.005). A significant correlation between improvement in UACR and CPAP compliance rates was also noted (Spearman's correlation coefficient: -0.37, P = 0.007). Baseline UACR, good CPAP compliance, and body mass index were independent predictors of changes in UACR.Adequate CPAP treatment improves albuminuria in OSAS patients. In addition to monitoring CPAP adherence and subjective sleepiness, UACR may offer an objective physiological index of CPAP therapeutic effectiveness. PMID:27368036

  2. Reversibility of albuminuria and continuous positive airway pressure compliance in patients of obstructive sleep apnea syndrome

    PubMed Central

    Chen, Ning-Hung; Chou, Yu-Ting; Lee, Pei-Hsien; Lin, Shih-Wei; Chuang, Li-Pang; Lin, Yu-Sheng; Yang, Cheng-Ta

    2016-01-01

    Abstract A positive correlation between albuminuria and severity of obstructive sleep apnea syndrome (OSAS) has been demonstrated, as indexed by urine albumin-to-creatinine ratios (UACRs). However, the effect of continuous positive airway pressure (CPAP) treatment on albuminuria in OSAS patients has not been established. Sixty subjects, with apnea-hypopnea indices >15 events per hour and no other diagnoses associated with albuminuria, underwent overnight polysomnography for sleep apnea and were examined for UACR at baseline and after 6 months of CPAP therapy. CPAP compliance rates were also recorded. Significant improvement in UACR was found in OSAS patients with good compliance to CPAP treatment after 6 months of therapy (baseline vs 6-month follow-up, 32.0 ± 9.5 vs 19.2 ± 6.5 mg/g, respectively, P = 0.007), whereas slight worsening in UACRs was noted in patients with poor compliance to CPAP treatment (baseline vs 6-month follow-up, respectively, 16.7 ± 4.4 vs 19.1 ± 6.3 mg/g, respectively, P = 0.39). Change in UACR was significant between poor compliance versus good compliance groups (2.4 ± 2.7 vs −12.8 ± 4.4 mg/g, respectively, t = 2.9, P = 0.005). A significant correlation between improvement in UACR and CPAP compliance rates was also noted (Spearman's correlation coefficient: −0.37, P = 0.007). Baseline UACR, good CPAP compliance, and body mass index were independent predictors of changes in UACR. Adequate CPAP treatment improves albuminuria in OSAS patients. In addition to monitoring CPAP adherence and subjective sleepiness, UACR may offer an objective physiological index of CPAP therapeutic effectiveness. PMID:27368036

  3. Improvement in exercise endurance in patients with chronic airflow limitation using continuous positive airway pressure.

    PubMed

    O'Donnell, D E; Sanii, R; Younes, M

    1988-12-01

    To cope with the increased ventilatory demands of exercise, patients with severe expiratory flow limitation adopt strategies that ultimately place greater demands on their inspiratory muscles. Increased inspiratory muscle work may contribute to dyspnea causation and exercise limitation in such patients even before their ventilatory ceiling is attained. In this setting, continuous positive airway pressure (CPAP) should, by favorably affecting inspiratory muscle function and respiratory sensation, improve exercise performance. Six patients with chronic airflow limitation (CAL) (FEV1 +/- SD = 35 +/- 12% predicted) undertook constant-load, submaximal, cycle exercise at 50% of their predetermined maximal oxygen consumption: CPAP of 4 to 5 cm H2O was delivered during one exercise session and bracketed by one or two unassisted control sessions. In four patients, CPAP-assisted (4 to 5 cm H2O) exercise was bracketed by two unassisted control exercise sessions; two remaining patients undertook CPAP-assisted exercise and one unassisted control session. CPAP resulted in a significant increase in exercise endurance time (TLIM) (by 48%: CPAP TLIM (mean +/- SE) = 8.82 +/- 1.90 min; averaged control TLIM = 5.98 +/- 1.23 min (p less than 0.01). CPAP effectively ameliorated exertional dyspnea in the majority of patients; selected dyspnea ratings (Borg scale) during control (final minute) and CPAP at isotime, at comparable levels of ventilation, were (mean +/- SD) 7.83 +/- 2.25 and 5.5 +/- 2.2, respectively (p less than 0.025). Breathing frequency fell significantly during CPAP application (at isotime) by 17% (p less than 0.02); other steady-state ventilatory variables and end-expiratory lung volumes were not significantly different during CPAP and control.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Continuous positive airway pressure and ventilation are more effective with a nasal mask than a full face mask in unconscious subjects: a randomized controlled trial

    PubMed Central

    2013-01-01

    Introduction Upper airway obstruction (UAO) is a major problem in unconscious subjects, making full face mask ventilation difficult. The mechanism of UAO in unconscious subjects shares many similarities with that of obstructive sleep apnea (OSA), especially the hypotonic upper airway seen during rapid eye movement sleep. Continuous positive airway pressure (CPAP) via nasal mask is more effective at maintaining airway patency than a full face mask in patients with OSA. We hypothesized that CPAP via nasal mask and ventilation (nCPAP) would be more effective than full face mask CPAP and ventilation (FmCPAP) for unconscious subjects, and we tested our hypothesis during induction of general anesthesia for elective surgery. Methods In total, 73 adult subjects requiring general anesthesia were randomly assigned to one of four groups: nCPAP P0, nCPAP P5, FmCPAP P0, and FmCPAP P5, where P0 and P5 represent positive end-expiratory pressure (PEEP) 0 and 5 cm H2O applied prior to induction. After apnea, ventilation was initiated with pressure control ventilation at a peak inspiratory pressure over PEEP (PIP/PEEP) of 20/0, then 20/5, and finally 20/10 cm H2O, each applied for 1 min. At each pressure setting, expired tidal volume (Vte) was calculated by using a plethysmograph device. Results The rate of effective tidal volume (Vte > estimated anatomical dead space) was higher (87.9% vs. 21.9%; P<0.01) and the median Vte was larger (6.9 vs. 0 mL/kg; P<0.01) with nCPAP than with FmCPAP. Application of CPAP prior to induction of general anesthesia did not affect Vte in either approach (nCPAP pre- vs. post-; 7.9 vs. 5.8 mL/kg, P = 0.07) (FmCPAP pre- vs. post-; 0 vs. 0 mL/kg, P = 0.11). Conclusions nCPAP produced more effective tidal volume than FmCPAP in unconscious subjects. Trial registration ClinicalTrials.gov identifier: NCT01524614. PMID:24365207

  5. Effects of Armodafinil on Simulated Driving and Self-Report Measures in Obstructive Sleep Apnea Patients prior to Treatment with Continuous Positive Airway Pressure

    PubMed Central

    Kay, Gary G.; Feldman, Neil

    2013-01-01

    Study Objectives: Obstructive sleep apnea (OSA) has been associated with an increased risk of motor vehicle crashes. This driving risk can be reduced (≥ 50%) by treatment with continuous positive airway pressure (CPAP). However residual excessive daytime sleepiness (EDS) can persist for some patients who regularly use CPAP. The current study was designed to assess the effect of armodafinil on simulated driving performance and subsequent CPAP treatment compliance in newly diagnosed OSA patients with EDS during a 2-week “waiting period” prior to initiation of CPAP. Methods: Sixty-nine newly diagnosed OSA patients, awaiting CPAP therapy, were randomized (1:1) to placebo or armodafinil (150 mg/day) treatment. Simulated driving tests and self-report measures were completed at baseline, after 2 weeks of drug treatment, and following 6 weeks of CPAP treatment. CPAP compliance was evaluated at the end of 6 weeks of CPAP. Results: Compared to placebo, armodafinil improved simulated driving safety performance in OSA patients awaiting CPAP therapy (p = 0.03). Improvement was seen in lane position deviation (p = 0.002) and number of lane excursions (p = 0.02). Improvement was also observed on measures of sleepiness using the Epworth Sleepiness Scale (ESS) and sleep related quality of life. Following 6 weeks of CPAP, there was also significant improvement observed on multiple measures of simulated driving performance. CPAP compliance did not differ between armodafinil-treated and placebo-treated patients (p = 0.80). Conclusions: Armodafinil was found to improve simulated driving performance in OSA patients with EDS prior to initiation of CPAP. Treatment with armodafinil showed no effect on subsequent CPAP compliance. Citation: Kay GG; Feldman N. Effects of armodafinil on simulated driving and self-report measures in obstructive sleep apnea patients prior to treatment with continuous positive airway pressure. J Clin Sleep Med 2013;9(5):445-454. PMID:23674935

  6. Patient and Partner Experiences With Obstructive Sleep Apnea and CPAP Treatment: A Qualitative Analysis.

    PubMed

    Luyster, Faith S; Dunbar-Jacob, Jacqueline; Aloia, Mark S; Martire, Lynn M; Buysse, Daniel J; Strollo, Patrick J

    2016-01-01

    Few studies have investigated factors associated with continuous positive airway pressure (CPAP) treatment for sleep apnea from the patients' and their partners' perspective. This qualitative research study explored patients' and partners' experiences of CPAP and facilitators and barriers to CPAP use, and elicited suggestions for a first-time CPAP user program. Data from 27 participants were collected via four sleep apnea patient and four partner focus groups. Qualitative content analysis identified five themes: knowledge of sleep apnea, effects of sleep apnea, effects of CPAP, barriers and facilitators of CPAP, and ideas for a new user support program. Patients and partners emphasized the importance of partner involvement in the early CPAP treatment period. These data suggest consideration of a couple-oriented approach to improving CPAP adherence.

  7. Management of severe obstructive sleep apnea using mandibular advancement devices with auto continuous positive airway pressures

    PubMed Central

    Upadhyay, Rashmi; Dubey, Abhishek; Kant, Surya; Singh, Balendra Pratap

    2015-01-01

    The use of continuous positive airway pressures (CPAP) is considered standard treatment of moderate to severe obstructive sleep apnea (OSA). Treatment of the disease poses a great challenge not only for its diagnostic purpose but also for its treatment part. In about 29-83% of the patients, treatment is difficult because of non-compliance resulting due to high pressures, air leaks and other related issues. In such situations, alternative methods of treatment need to be looked for so as to ascertain better management. Mandibular advancement devices along with CPAP may show better treatment outcome in specific situations. PMID:25814802

  8. Otic Barotrauma Resulting from Continuous Positive Airway Pressure: Case Report and Literature Review

    PubMed Central

    McCormick, Justin P.; Hildrew, Douglas M.; Lawlor, Claire M.; Guittard, Jesse A.; Worley, N. Knight

    2016-01-01

    Background: Obstructive sleep apnea (OSA) is a growing problem affecting millions of people in the United States. The prevalence of OSA has risen drastically in the past few decades concurrently with the increasing prevalence of obesity. Subsequently, there has been an ever-increasing rise in the use of continuous positive airway pressure (CPAP) devices. While using CPAP devices may lead to many adverse effects, the majority of these effects are described as relatively benign. Case Report: We describe the detailed clinical course and outcome for a patient with otic barotrauma as a result of excessive self-titration of CPAP therapy in an in-home setting. We also discuss the pathophysiology of otic barotrauma and present a review of current literature on the topic. Conclusion: While the benefits of CPAP are clear, we must take into account the rare but possible effects on ear structure and function. Many studies describe an increase in middle ear pressure with the use of CPAP, but few describe the effects of this increased pressure on the middle ear, such as the otic barotrauma described in this case. Given the increased prevalence of OSA, it is important to understand the risks associated with CPAP therapy. PMID:27303224

  9. Auto-adjusting Positive Airway Pressure Treatment for Sleep Apnea Diagnosed by Home Sleep Testing

    PubMed Central

    Berry, Richard B.; Sriram, Peruvemba

    2014-01-01

    Study Objectives: Compare auto-adjusting positive airway pressure (APAP) treatment with positive airway pressure (PAP) titration by polysomnography (PSG) followed by CPAP treatment in patients diagnosed with obstructive sleep apnea (OSA) by home sleep apnea testing (HSAT). Design: Prospective randomized treatment study. Setting: Tertiary Veterans Administration Medical Center. Participants: 156 patients diagnosed with OSA by HSAT (apneahypopnea index [AHI] ≥ 10/h) suitable for APAP treatment. Interventions: APAP arm: Treatment with an APAP device, CPAP arm: PSG PAP titration followed by CPAP treatment. Measurements: Mean PAP adherence, Epworth sleepiness scale (ESS), Functional Outcomes of Sleep Questionnaire (FOSQ). Results: The mean (± SD) age, BMI, and diagnostic AHI (APAP: 28.6 ± 18.5, CPAP: 28.3 ± 16.0/h, p = NS) did not differ between the study arms. After 6 weeks of treatment, 84.6% of 78 patients started on APAP and 84.3% of 70 patients started on CPAP (8 declined treatment after the titration) were using PAP, p = NS. The 90% APAP and level of CPAP were similar (10.8 ± 3.1, 11.7 ± 2.5 cm H2O, p = 0.07). The average nightly PAP use did not differ (APAP: 4.45 ± 2.3, CPAP: 4.0 ± 2.3 h, p = NS). The improvements in the ESS (APAP: −4.2 ± 4.7, CPAP: −3.7 ± 4.8, p = NS) and in the FOSQ (APAP: 2.6 ± 3.5, CPAP: 2.2 ± 3.7, p = NS) were not different. Conclusions: Following diagnosis of OSA by HSAT, treatment with APAP results in equivalent PAP adherence and improvement in sleepiness compared to a PSG titration and CPAP treatment. Commentary: A commentary on this article appears in this issue on page 1277. Citation: Berry RB, Sriram P. Auto-adjusting positive airway pressure treatment for sleep apnea diagnosed by home sleep testing. J Clin Sleep Med 2014;10(12):1269-1275. PMID:25348244

  10. Effectiveness of applying continuous positive airway pressure in a patient with paradoxical vocal fold movement after endotracheal extubation: a case report

    PubMed Central

    Song, Keu La Me; Ko, Dong Chan; Pin, Jung Woo; Ryu, Kyong Ho; Kim, Hyun Soo

    2016-01-01

    Paradoxical vocal fold movement (PVFM) is an uncommon upper airway disorder defined as paradoxical adduction of the vocal folds during inspiration. The etiology and treatment of PVFM are unclear. The physician should manage this condition because of the possibility of near complete airway obstruction in severe case of PVFM. We report a case of successful airway management in a patient with PVFM by applying continuous positive airway pressure (CPAP). In this case, PVFM was detected after removing an endotracheal tube from a 67-year-old male who underwent excision of a laryngeal mass. The patient recovered without complications in 1 day with support by CPAP. PMID:26885309

  11. Long-term effects of nocturnal continuous positive airway pressure therapy in patients with resistant hypertension and obstructive sleep apnea.

    PubMed

    Frenţ, Ştefan M; Tudorache, Voicu M; Ardelean, Carmen; Mihăicuţă, Stefan

    2014-01-01

    Obstructive sleep apnea (OSA) is often linked to high blood pressure and has a particularly high prevalence in patients with resistant hypertension. The effect of continuous positive airway pressure (CPAP) therapy on blood pressure (BP) values has been evaluated in several short-term clinical trials with conflicting results. Our aim was to investigate the role of long-term CPAP treatment in achieving BP control in patients who associate OSA and resistant hypertension. We have included in the study 33 patients with resistant hypertension, diagnosed with OSA in our sleep lab. Data was collected initially and after a mean follow-up period of 4 years. Patients were divided into 2 groups according to the use of CPAP therapy. Patients under CPAP therapy (n = 12) exhibited a higher reduction in both systolic and diastolic pressure and BP control was achieved in 75% of cases, while patients without CPAP treatment (n = 21) remained with refractory hypertension in proportion of 90.5%. A de-escalation of antihypertensive drug regimen by discontinuation of 1 or more drugs was observed in 41.6% (n = 5) of patients from CPAP group and in the other 33.4% (n = 4) the medication remained unchanged, but BP control was reached. Using a direct logistic regression model for examining the impact of different confounders on the probability of diagnosis of resistant hypertension at follow-up, the only statistically significant predictor found was the lack of CPAP usage. PMID:25665364

  12. Long-term effects of nasal continuous positive airway pressure on vasodilatory endothelial function in obstructive sleep apnea syndrome.

    PubMed

    Duchna, Hans-W; Orth, Maritta; Schultze-Werninghaus, Gerhard; Guilleminault, Christian; Stoohs, Riccardo A

    2005-09-01

    Obstructive sleep apnea syndrome (OSAS) is associated with a dysfunction of vascular endothelial cells. The aim of this study was to investigate long-term improvement of endothelial dysfunction in OSAS with nasal continuous positive airway pressure (nCPAP) treatment. We investigated endothelium-dependent and endothelium-independent vasodilatory function in patients with OSAS using the hand vein compliance technique. Dose-response curves to endothelium-dependent vasodilator bradykinin were obtained in 16 subjects with OSAS before and after 6 months of nCPAP therapy and in 12 control subjects without OSAS. Maximum dilation (Emax) to bradykinin, being impaired in all OSAS patients, was completely restored with nCPAP. Mean Emax to bradykinin rose from 54.9+/-18.5 to 108.2+/-28.7% with 164.4+/-90.0 nights of nCPAP therapy (p<0.0001; Emax healthy controls, 94.8+/-9.5%). At treatment follow-up, endothelium-dependent vasodilatory capacity was not significantly different in nCPAP-treated OSAS patients vs healthy controls. Mean vasodilation with endothelium independently acting nitroglycerin was not altered initially and did not change with nCPAP therapy indicating that nCPAP restored endothelial cell function and not unspecific, endothelium-independent factors. These results suggest that regular nocturnal nCPAP treatment leads to a sustained restoration of OSAS-induced impaired endothelium-dependent nitric oxide-mediated vasodilation, suggesting an improvement of systemic endothelial dysfunction in patients studied.

  13. Residual Daytime Sleepiness in Obstructive Sleep Apnea After Continuous Positive Airway Pressure Optimization: Causes and Management.

    PubMed

    Chapman, Julia L; Serinel, Yasmina; Marshall, Nathaniel S; Grunstein, Ronald R

    2016-09-01

    Excessive daytime sleepiness (EDS) is common in obstructive sleep apnea (OSA), but it is also common in the general population. When sleepiness remains after continuous positive airway pressure (CPAP) treatment of OSA, comorbid conditions or permanent brain injury before CPAP therapy may be the cause of the residual sleepiness. There is currently no broad approach to treating residual EDS in patients with OSA. Individual assessment must be made of comorbid conditions and medications, and of lifestyle factors that may be contributing to the sleepiness. Modafinil and armodafinil are the only pharmacologic agents indicated for residual sleepiness in these patients. PMID:27542881

  14. Obstructive sleep apnoea in the elderly: role of continuous positive airway pressure treatment.

    PubMed

    Martínez-García, Miguel Ángel; Chiner, Eusebi; Hernández, Luis; Cortes, Jose Pascual; Catalán, Pablo; Ponce, Silvia; Diaz, Jose Ramón; Pastor, Ester; Vigil, Laura; Carmona, Carmen; Montserrat, Josep Maria; Aizpuru, Felipe; Lloberes, Patricia; Mayos, Mercedes; Selma, Maria José; Cifuentes, Jose Fernando; Muñoz, Alvaro

    2015-07-01

    Almost all the information about the effect of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnoea (OSA) comes from clinical trials involving only middle-aged patients. The objective of this study was to assess the effect of CPAP treatment in elderly patients with severe OSA on clinical, quality-of-life and neurocognitive spheres. We performed an open-label, randomised, multicentre clinical trial in a consecutive clinical cohort of 224 elderly (≥70 years old) patients with confirmed severe OSA (apnoea-hypopnea index ≥30) randomised to receive CPAP (n=115) or no CPAP (n=109) for 3 months. A sleep study was performed by either full polysomnography or respiratory polygraphy. CPAP titration was performed by an autoCPAP device. The primary endpoint was quality of life (Quebec Sleep Questionnaire) and secondary endpoints included sleep-related symptoms, presence of anxiety/depression, office-based blood pressure and some neurocognitive tests. The mean±sd age was 75.5±3.9 years. The CPAP group achieved a greater improvement in all quality-of-life domains (p<0.001; effect size: 0.41-0.98), sleep-related symptoms (p<0.001; effect size 0.31-0.91) as well as anxiety (p=0.016; effect size 0.51) and depression (p<0.001; effect size: 0.28) indexes and some neurocognitive tests (digit symbol test (p=0.047; effect size: 0.20) and Trail Making Test A (p=0.029; effect size: 0.44)) in an intention-to-treat analysis. In conclusion, CPAP treatment resulted in an improvement in quality of life, sleep-related symptoms, anxiety and depression indexes and some neurocognitive aspects in elderly people with severe OSA.

  15. Effect of Acute Intermittent CPAP Depressurization during Sleep in Obese Patients

    PubMed Central

    Jun, Jonathan C.; Unnikrishnan, Dileep; Schneider, Hartmut; Kirkness, Jason; Schwartz, Alan R.; Smith, Philip L.; Polotsky, Vsevolod Y.

    2016-01-01

    Background Obstructive Sleep Apnea (OSA) describes intermittent collapse of the airway during sleep, for which continuous positive airway pressure (CPAP) is often prescribed for treatment. Prior studies suggest that discontinuation of CPAP leads to a gradual, rather than immediate return of baseline severity of OSA. The objective of this study was to determine the extent of OSA recurrence during short intervals of CPAP depressurization during sleep. Methods Nine obese (BMI = 40.4 ± 3.5) subjects with severe OSA (AHI = 88.9 ± 6.8) adherent to CPAP were studied during one night in the sleep laboratory. Nasal CPAP was delivered at therapeutic (11.1 ± 0.6 cm H20) or atmospheric pressure, in alternating fashion for 1-hour periods during the night. We compared sleep architecture and metrics of OSA during CPAP-on and CPAP-off periods. Results 8/9 subjects tolerated CPAP withdrawal. The average AHI during CPAP-on and CPAP-off periods was 3.6 ± 0.6 and 15.8 ± 3.6 respectively (p<0.05). The average 3% ODI during CPAP-on and CPAP-off was 4.7 ± 2 and 20.4 ± 4.7 respectively (p<0.05). CPAP depressurization also induced more awake (p<0.05) and stage N1 (p<0.01) sleep, and less stage REM (p<0.05) with a trend towards decreased stage N3 (p = 0.064). Conclusion Acute intermittent depressurization of CPAP during sleep led to deterioration of sleep architecture but only partial re-emergence of OSA. These observations suggest carryover effects of CPAP. PMID:26731735

  16. Bubble Continuous Positive Airway Pressure Enhances Lung Volume and Gas Exchange in Preterm Lambs

    PubMed Central

    Pillow, J. Jane; Hillman, Noah; Moss, Timothy J. M.; Polglase, Graeme; Bold, Geoff; Beaumont, Chris; Ikegami, Machiko; Jobe, Alan H.

    2007-01-01

    Rationale: The technique used to provide continuous positive airway pressure (CPAP) to the newborn may influence lung function and breathing efficiency. Objectives: To compare differences in gas exchange physiology and lung injury resulting from treatment of respiratory distress with either bubble or constant pressure CPAP and to determine if the applied flow influences short-term outcomes. Methods: Lambs (133 d gestation; term is 150 d) born via cesarean section were weighed, intubated, and treated with CPAP for 3 hours. Two groups were treated with 8 L/minute applied flow using the bubble (n = 12) or the constant pressure (n = 12) technique. A third group (n = 10) received the bubble method with 12 L/minute bias flow. Measurements at study completion included arterial blood gases, oxygraphy, capnography, tidal flow, multiple breath washout, lung mechanics, static pressure–volume curves, and bronchoalveolar lavage fluid protein. Measurements and Main Results: Birth weight and arterial gas variables at 15 minutes were comparable. Flow (8 or 12 L/min) did not influence the 3-hour outcomes in the bubble group. Bubble technique was associated with a higher pH, PaO2, oxygen uptake, and area under the flow–volume curve, and a decreased alveolar protein, respiratory quotient, PaCO2, and ventilation inhomogeneity compared with the constant pressure group. Conclusions: Compared with constant pressure technique, bubble CPAP promotes enhanced airway patency during treatment of acute postnatal respiratory disease in preterm lambs and may offer protection against lung injury. PMID:17431223

  17. Nocturnal nasal continuous positive airway pressure in patients with chronic obstructive pulmonary disease. Influence on waking respiratory muscle function.

    PubMed

    Mezzanotte, W S; Tangel, D J; Fox, A M; Ballard, R D; White, D P

    1994-10-01

    Patients with COPD often have reduced inspiratory muscle strength and endurance as well as poor exercise tolerance. Increased inspiratory work during sleep (probably due to increased upper airway resistance) may further strain these compromised respiratory muscles in COPD patients. We hypothesized that nasal continuous positive airway pressure (CPAP) might reduce respiratory work during sleep in COPD patients and thereby improve waking inspiratory muscle function. To test this hypothesis, eight male COPD patients were treated with sustained nocturnal nasal CPAP. Inspiratory muscle strength (maximum inspiratory pressure) and endurance (sustained inspiratory pressure) as well as clinical performance (12-min walk) were assessed before and after therapy. We observed that compared with matched controls, COPD patients treated with nocturnal nasal CPAP had significant and substantial improvement in inspiratory muscle strength and endurance as well as functional ability as assessed by the 12-min walk. In addition, CPAP did not significantly alter sleep quality or oxygenation in the patients studied. We conclude that nocturnal nasal CPAP improves inspiratory muscle performance during wakefulness in COPD patients, which is very likely a product of the reduced work of breathing during sleep while these individuals received CPAP.

  18. Is inconsistent pre-treatment bedtime related to CPAP non-adherence?

    PubMed

    Sawyer, Amy M; King, Tonya S; Sawyer, Douglas A; Rizzo, Albert

    2014-12-01

    Lack of adherence to continuous positive airway pressure therapy (CPAP) limits the effectiveness of treatment of obstructive sleep apnea (OSA). We hypothesized that an irregular bedtime would be negatively related to regular use of CPAP treatment. If so, modifying bedtime schedule may address the persistent problem of inconsistent CPAP use in adults with OSA. In a prospective longitudinal study, we examined whether inconsistent self-reported bedtime before initiation of CPAP treatment, operationalized as bedtime variability, was (1) different among those adherent (≥4 hours per night) and non-adherent to CPAP treatment at 1 week and 1 month; and/or (2) was related to 1-week and 1-month CPAP use when other variables were accounted for. Consecutively recruited newly diagnosed OSA adults (n = 79) completed sleep diaries prior to CPAP treatment. One-week and 1-month objective CPAP use data were collected. Pre-treatment bedtime variability was different among CPAP non-adherers and adherers at 1 month and was a significant predictor of non-adherence at 1 month in multi-variable analyses. The odds of 1-month CPAP non-adherence were 3.5 times greater in those whose pre-treatment bedtimes varied by >75 minutes. Addressing sleep schedule prior to CPAP initiation may be an opportunity to improve CPAP adherence.

  19. A high flow turbine CPAP system.

    PubMed

    Moran, J L; Jackson, M P; Cameron, D M; Peisach, A R; Cunningham, D N; O'Fathartaigh, M S

    1988-01-01

    A continuous high flow CPAP system incorporating a turbine blower is described. The system achieves inspiratory flow rates of 150 l/min or more by means of reticulated gas flow and inspired oxygen fractions of 0.21-0.95. Positive airway pressure is provided by weighted disc valves and a modified aviation-type CPAP face mask provides electronic communication with the patient. The mobility of the system also enables its use as an intermittent physiotherapy aid. Work of breathing of the system, as assessed by total pressure fluctuations is at a minimum.

  20. Effectiveness of flow inflating device in providing Continuous Positive Airway Pressure for critically ill children in limited-resource settings: A prospective observational study

    PubMed Central

    Anitha, G. Fatima Shirly; Velmurugan, Lakshmi; Sangareddi, Shanthi; Nedunchelian, Krishnamurthy; Selvaraj, Vinoth

    2016-01-01

    Background and Aims: Noninvasive ventilation (NIV) is an emerging popular concept, which includes bi-level positive airway pressure or continuous positive airway pressure (CPAP). In settings with scarce resources for NIV machines, CPAP can be provided through various indigenous means and one such mode is flow inflating device - Jackson-Rees circuit (JR)/Bain circuit. The study analyses the epidemiology, various clinical indications, predictors of CPAP failure, and stresses the usefulness of flow inflating device as an indigenous way of providing CPAP. Methods: A prospective observational study was undertaken in the critical care unit of a Government Tertiary Care Hospital, from November 2013 to September 2014. All children who required CPAP in the age group 1 month to 12 years of both sexes were included in this study. They were started on indigenous CPAP through flow inflating device on clinical grounds based on the pediatric assessment triangle, and the duration and outcome were analyzed. Results: This study population included 214 children. CPAP through flow inflating device was successful in 89.7% of cases, of which bronchiolitis accounted for 98.3%. A prolonged duration of CPAP support of >96 h was required in pneumonia. CPAP failure was noted in 10.3% of cases, the major risk factors being children <1 year and pneumonia with septic shock. Conclusion: We conclude that flow inflating devices - JR/Bain circuit are effective as an indigenous CPAP in limited resource settings. Despite its benefits, CPAP is not a substitute for invasive ventilation, as when the need for intubation arises timely intervention is needed.

  1. Effectiveness of flow inflating device in providing Continuous Positive Airway Pressure for critically ill children in limited-resource settings: A prospective observational study

    PubMed Central

    Anitha, G. Fatima Shirly; Velmurugan, Lakshmi; Sangareddi, Shanthi; Nedunchelian, Krishnamurthy; Selvaraj, Vinoth

    2016-01-01

    Background and Aims: Noninvasive ventilation (NIV) is an emerging popular concept, which includes bi-level positive airway pressure or continuous positive airway pressure (CPAP). In settings with scarce resources for NIV machines, CPAP can be provided through various indigenous means and one such mode is flow inflating device - Jackson-Rees circuit (JR)/Bain circuit. The study analyses the epidemiology, various clinical indications, predictors of CPAP failure, and stresses the usefulness of flow inflating device as an indigenous way of providing CPAP. Methods: A prospective observational study was undertaken in the critical care unit of a Government Tertiary Care Hospital, from November 2013 to September 2014. All children who required CPAP in the age group 1 month to 12 years of both sexes were included in this study. They were started on indigenous CPAP through flow inflating device on clinical grounds based on the pediatric assessment triangle, and the duration and outcome were analyzed. Results: This study population included 214 children. CPAP through flow inflating device was successful in 89.7% of cases, of which bronchiolitis accounted for 98.3%. A prolonged duration of CPAP support of >96 h was required in pneumonia. CPAP failure was noted in 10.3% of cases, the major risk factors being children <1 year and pneumonia with septic shock. Conclusion: We conclude that flow inflating devices - JR/Bain circuit are effective as an indigenous CPAP in limited resource settings. Despite its benefits, CPAP is not a substitute for invasive ventilation, as when the need for intubation arises timely intervention is needed. PMID:27630454

  2. Early Bubble Continuous Positive Airway Pressure: Investigating Interprofessional Best Practices for the NICU Team.

    PubMed

    Casey, Jessica L; Newberry, Desi; Jnah, Amy

    2016-01-01

    Premature neonates delivered <32 completed weeks gestation are unprepared to handle the physiologic demands of extrauterine life. Within the respiratory system, alveolar instability and collapse can cause decreased functional residual capacity, impaired oxygenation, and hypoxemia leading to respiratory distress syndrome. Supportive measures are indicated immediately after birth to establish physiologic stability including bubble continuous positive airway pressure (CPAP) or endotracheal intubation and mechanical ventilation. CPAP is a noninvasive, gentle mode of ventilation that can mitigate the effects of lung immaturity, but prolonged use can increase the risk for nasal breakdown. Strategies to mitigate this risk must be infused as best practices in the NICU environment. The purpose of this article is to propose an evidence-based best practice care bundle for the early initiation of CPAP in the delivery room and associated skin barrier protection strategies for premature neonates <32 weeks gestation and weighing <1,500 g. PMID:27194606

  3. Pressure-Relief Features of Fixed and Autotitrating Continuous Positive Airway Pressure May Impair Their Efficacy: Evaluation with a Respiratory Bench Model

    PubMed Central

    Zhu, Kaixian; Aouf, Sami; Roisman, Gabriel; Escourrou, Pierre

    2016-01-01

    Study Objectives: Pressure-relief features are aimed at improving the patient's comfort during continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea. The objective of this study was to determine the effect of these therapy features on fixed CPAP and autotitrating CPAP (APAP) treatment efficacy. Methods: Seven pressure-relief features applied by three CPAP devices were included in our study (Remstar Auto: C-Flex 3, C-Flex+ 3, A-Flex 3, P-Flex; AirSense 10: EPR 3; Prisma 20A: SoftPAP 2 and 3). In fixed CPAP, the devices were subjected to a 10-min bench-simulated obstructive apnea sequence (initial apnea-hypopnea index, AHI = 60/h) with and without pressure-relief features. In APAP, the sequence was lengthened to 4.2 h (initial AHI = 58.6/h). The residual AHI and mean/median pressure were compared with and without pressure-relief features. Results: Compared to conventional CPAP, where pressure was adjusted to be just sufficient to control the simulated obstructive events, C-Flex+ 3, P-Flex, and EPR 3 failed to normalize the breathing flow and did not reduce the AHI. The mean pressures with the three features, respectively, were 1.8, 2.6, and 2.6 cmH2O lower than the conventional CPAP. Compared to conventional APAP, similar levels of control were observed with pressure-relief features, apart from P-Flex where the delivered mean pressure was lower and residual AHI greater. The device-reported mean/median pressures in APAP with A-Flex 3, P-Flex, EPR 3, and SoftPAP 3 were higher than that measured on the bench. Conclusions: Pressure-relief features may attenuate CPAP efficacy if not adjusted for at the time of their introduction. In clinical practice, efficacy can be ensured by increasing the therapeutic pressure delivered by fixed CPAP or by enabling the pressure-relief features prior to initial pressure titration. Device-reported pressures in APAP devices with pressure relief activated may overstate delivered pressures. Citation: Zhu K, Aouf S

  4. Gender Differences in Obstructive Sleep Apnea and Treatment Response to Continuous Positive Airway Pressure

    PubMed Central

    Ye, Lichuan; Pien, Grace W.; Ratcliffe, Sarah J.; Weaver, Terri E.

    2009-01-01

    Objectives: Whether gender differences exist in clinical manifestations of obstructive sleep apnea (OSA) and whether women's responses to continuous positive airway pressure (CPAP) are similar to those of men are critical areas of exploration in sleep disordered breathing. This exploratory analysis addressed these questions by examining gender differences over a wide range of clinical outcomes at baseline and in response to CPAP in participants with severe OSA. Methods: Data from 152 men and 24 women who participated in a multicenter CPAP effectiveness study were analyzed. Gender differences in functional status (functional outcomes of sleep questionnaire, sickness impact profile), daytime sleepiness (epworth sleepiness scale, multiple sleep latency test), mood disturbance (profile of mood states), apnea symptoms (multivariable apnea prediction index), and neurobehavioral performance (psychomotor vigilance task) were examined. Treatment response was examined by the change in each outcome from baseline to 3 months after treatment. Results: Despite similar age, body mass index, and apnea-hypopnea index, women reported significantly lower functional status, more subjective daytime sleepiness, higher frequency of apnea symptoms, more mood disturbance, and poorer neurobehavioral performance compared to men at baseline. CPAP treatment significantly improved functional status and relieved symptoms for both genders. The magnitude of improvement in each clinical outcome did not vary by gender. Conclusions: Women with OSA showed greater impairment in daytime functioning and symptoms than men. Both genders benefit from CPAP treatment. Adequately powered studies considering possible referral and response bias are necessary to examine gender differences in OSA clinical manifestations and response to CPAP treatment. Citation: Ye L; Pien GW; Ratcliffe SJ; Weaver TE. Gender Differences in Obstructive Sleep Apnea and Treatment Response to Continuous Positive Airway Pressure. J Clin

  5. Cheyne-Stokes respiration in congestive heart failure: continuous positive airway pressure of 5-8 cm H2O for 1 year in five cases.

    PubMed

    Yasuma, Fumihiko

    2005-01-01

    Five adult patients with congestive heart failure (CHF) due to dilated cardiomyopathy complicated by Cheyne-Stokes respiration/central sleep apnea (CSR/CSA) were treated with continuous positive airway pressure (CPAP) with an initial pressure of 5 cm H2O. Four patients were followed up for 12 months with CPAP of 5 cm H2O. The rest, a 93-year-old patient, was followed up for 30 months, and the CPAP was reset at 8 cm H2O due to worsened cardiac function after 6 months and it was reset at 6 cm H2O due to dryness of the nose after 23 months. For all the patients with nightly CPAP use for 6.0+/-1.4 h per day for a year, frequency of CSR/CSA was significantly reduced after 3 and 12 months with CPAP (p<0.05). Moreover, their symptoms, cardiac function and sleep quality were significantly improved after 3 months (p<0.05), and were maintained above the pre-CPAP levels after 12 months, except for the oldest patient whose cardiac function tended to deteriorate. The results suggest that CSR/CSA in CHF can be treated with CPAP set at a lower pressure than the conventional method, and that CPAP at 5-8 cm H2O is often effective in eliminating CSR/CSA, improving sleep quality, and presumably maintaining cardiac function.

  6. Continuous positive airway pressure increases heart rate variability in heart failure patients with obstructive sleep apnoea.

    PubMed

    Gilman, Matthew P; Floras, John S; Usui, Kengo; Kaneko, Yasuyuki; Leung, Richard S T; Bradley, T Douglas

    2008-02-01

    Patients with heart failure or OSA (obstructive sleep apnoea) have reduced HF-HRV (high-frequency heart rate variability), indicating reduced cardiac vagal modulation, a marker of poor prognosis. CPAP (continuous positive airway pressure) abolishes OSA in patients with heart failure, but effects on daytime HF-HRV have not been determined. We hypothesized that, in patients with heart failure, treatment of coexisting OSA by CPAP would increase morning HF-HRV. In 19 patients with heart failure (left ventricular ejection fraction <45%) and OSA (>/=20 apnoeas and hypopnoeas/h of sleep), HF-HRV was quantified before and 1 month after randomization to a control or CPAP-treated group. In the control group (n=7), there were no changes in HF-HRV over the 1 month study during wakefulness in the morning. In the CPAP-treated group (n=12) HF-HRV increased significantly during wakefulness in the morning [from 2.43+/-0.55 to 2.82+/-0.50 log(ms(2)/Hz); P=0.002] due to an increase in transfer function between changes in lung volume and changes in HF-HRV (92.37+/-96.03 to 219.07+/-177.14 ms/l; P=0.01). In conclusion, treatment of coexisting OSA by nocturnal CPAP in patients with heart failure increases HF-HRV during morning wakefulness, indicating improved vagal modulation of heart rate. This may contribute to improved prognosis.

  7. Biomarkers of oxidative stress following continuous positive airway pressure withdrawal: data from two randomised trials.

    PubMed

    Stradling, John R; Schwarz, Esther I; Schlatzer, Christian; Manuel, Ari R; Lee, Regent; Antoniades, Charalambos; Kohler, Malcolm

    2015-10-01

    There is conflicting evidence whether intermittent hypoxia in obstructive sleep apnoea (OSA) influences oxidative stress. We hypothesised that withdrawal of continuous positive airway pressure (CPAP) from patients with OSA would raise markers of oxidative stress.59 patients with CPAP-treated moderate-to-severe OSA (oxygen desaturation index (ODI) >20 events·h(-1)) were randomised 1:1 to either stay on CPAP (n=30) or change to sham CPAP (n=29) for 2 weeks. Using samples from two similar studies at two sites, we measured early morning blood malondialdehyde (MDA, a primary outcome in one study and a secondary outcome in the other), lipid hydroperoxides, total antioxidant capacity, superoxide generation from mononuclear cells and urinary F2-isoprostane. We also measured superoxide dismutase as a marker of hypoxic preconditioning. "Treatment" effects (sham CPAP versus CPAP) were calculated via linear regression.Sham CPAP provoked moderate-to-severe OSA (mean ODI 46 events·h(-1)), but blood markers of oxidative stress did not change significantly (MDA "treatment" effect (95% CI) -0.02 (-0.23 to +0.19) μmol·L(-1)). Urinary F2-isoprostane fell significantly by ~30% (-0.26 (-0.42 to -0.10) ng·mL(-1)) and superoxide dismutase increased similarly (+0.17 (+0.02 to +0.30) ng·mL(-1)).We found no direct evidence of increased oxidative stress in patients experiencing a return of their moderate-to-severe OSA. The fall in urinary F2-isoprostane and rise in superoxide dismutase implies that hypoxic preconditioning may have reduced oxidative stress.

  8. Application of continuous positive airway pressure in the delivery room: a multicenter randomized clinical trial

    PubMed Central

    Gonçalves-Ferri, W.A.; Martinez, F.E.; Caldas, J.P.S.; Marba, S.T.M.; Fekete, S.; Rugolo, L.; Tanuri, C.; Leone, C.; Sancho, G.A.; Almeida, M.F.B.; Guinsburg, R.

    2014-01-01

    This study evaluated whether the use of continuous positive airway pressure (CPAP) in the delivery room alters the need for mechanical ventilation and surfactant during the first 5 days of life and modifies the incidence of respiratory morbidity and mortality during the hospital stay. The study was a multicenter randomized clinical trial conducted in five public university hospitals in Brazil, from June 2008 to December 2009. Participants were 197 infants with birth weight of 1000-1500 g and without major birth defects. They were treated according to the guidelines of the American Academy of Pediatrics (APP). Infants not intubated or extubated less than 15 min after birth were randomized for two treatments, routine or CPAP, and were followed until hospital discharge. The routine (n=99) and CPAP (n=98) infants studied presented no statistically significant differences regarding birth characteristics, complications during the prenatal period, the need for mechanical ventilation during the first 5 days of life (19.2 vs 23.4%, P=0.50), use of surfactant (18.2 vs 17.3% P=0.92), or respiratory morbidity and mortality until discharge. The CPAP group required a greater number of doses of surfactant (1.5 vs 1.0, P=0.02). When CPAP was applied to the routine group, it was installed within a median time of 30 min. We found that CPAP applied less than 15 min after birth was not able to reduce the need for ventilator support and was associated with a higher number of doses of surfactant when compared to CPAP applied as clinically indicated within a median time of 30 min. PMID:24554040

  9. Continuous positive airway pressure for bronchiolitis in a general paediatric ward; a feasibility study

    PubMed Central

    2014-01-01

    Background Continuous positive airway pressure (CPAP) is commonly used to relieve respiratory distress in infants with bronchiolitis, but has mostly been studied in an intensive care setting. Our prime aim was to evaluate the feasibility of CPAP for infants with bronchiolitis in a general paediatric ward, and secondary to assess capillary PCO2 (cPCO2) levels before and during treatment. Methods From May 1st 2008 to April 30th 2012, infants with bronchiolitis at Stavanger University Hospital were treated with CPAP in a general paediatric ward, but could be referred to an intensive care unit (ICU) when needed, according to in-house guidelines. Levels of cPCO2 were prospectively registered before the start of CPAP and at approximately 4, 12, 24 and 48 hours of treatment as long as CPAP was given. We had a continuous updating program for the nurses and physicians caring for the infants with CPAP. The study was population based. Results 672 infants (3.4%) were hospitalized with bronchiolitis. CPAP was initiated in 53 infants (0.3%; 7.9% of infants with bronchiolitis), and was well tolerated in all but three infants. 46 infants were included in the study, the majority of these (n = 33) were treated in the general ward only. These infants had lower cPCO2 before treatment (8.0; 7.7, 8.6)(median; quartiles) than those treated at the ICU (n = 13) (9.3;8.5, 9.9) (p < 0.001). The level of cPCO2 was significantly reduced after 4 h in both groups; 1.1 kPa (paediatric ward) (p < 0.001) and 1.3 kPa (ICU) (p = 0.002). Two infants on the ICU did not respond to CPAP (increasing cPCO2 and severe apnoe) and were given mechanical ventilation, otherwise no side effects were observed in either group treated with CPAP. Conclusion Treatment with CPAP for infants with bronchiolitis may be feasible in a general paediatric ward, providing sufficient staffing and training, and the possibility of referral to an ICU when needed. PMID:24886569

  10. The effect of positive reinforcement on hourly compliance in nasal continuous positive airway pressure users with obstructive sleep apnea.

    PubMed

    Fletcher, E C; Luckett, R A

    1991-05-01

    Previous reports have described compliance with nasal continuous positive airway pressure (nCPAP) for the treatment of obstructive sleep apnea (OSA) only in terms of the number of patients able to use it beyond their initial trial night or those continuing after some home use. Because of a possible difference between the level of compliance (mean number of hours of use per 24 h) needed for symptomatic relief of OSA versus cardiovascular improvement, the level of hourly compliance in chronic nCPAP users may be important. The first part of this study prospectively examines compliance in a stable population of OSA patients already using nCPAP for 6 months to 2 yr. The second part is a prospective randomized, crossover study examining the effect of weekly (three times) then monthly (twice) positive reinforcement on hourly compliance of new nCPAP users for 3 months versus no reinforcement for 3 months. Positive reinforcement consisted of telephone discussions with the patients about the severity or complications of OSA, benefits of nCPAP, and suggestions about minimizing side effects. Using self-assessment scales, each patient reported the perceived level of improvement from the untreated to the treated condition and the prevalence and severity of side effects from the nCPAP therapy. The level of compliance in stable, chronic nCPAP users with OSA was 6.1 +/- 2.2 h/24 h (n = 9). For the new nCPAP users during the nonreinforced period, the mean compliance was 6.0 +/- 2.8 h/24 h; that during the reinforcement period was 6.0 +/- 2.7 h/24 h (NS). There was no significant correlation between perceived improvement in OSA symptoms or between the perceived side effects of nCPAP versus hourly compliance.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. [Legionella pneumonia after the use of CPAP equipment].

    PubMed

    Stolk, Jaap M; Russcher, Anne; van Elzakker, Erika P M; Schippers, Emile F

    2016-01-01

    Continuous positive airway pressure (CPAP) equipment can be colonised by Legionellae and might cause Legionella pneumonia in the user. However, there is no reported case of Legionella pneumonia related to CPAP equipment in which an identical Legionella was found in both the patient and the CPAP equipment. A 51-year-old man came to the Emergency Department with fever, confusion and dyspnoea that had been present for 3 days. His medical history included obstructive sleep apnoea, for which he had been using CPAP therapy at home for 10 weeks. The CPAP equipment showed signs of poor maintenance. Chest X-ray revealed a pulmonary consolidation. Laboratory investigation resulted in a positive urine antigen test for Legionella. Water from the CPAP equipment and sputum from the patient revealed Legionella pneumophila. Serotyping and sequence-based typing showed an identical L. pneumophila serotype 1 ST37. It is important to be aware that CPAP equipment can be colonised with Legionellae and might cause Legionella pneumonia. It is therefore necessary to ask about CPAP therapy in a patient with community-acquired pneumonia.

  12. The Effect of Nasal Surgery on Continuous Positive Airway Pressure Device Use and Therapeutic Treatment Pressures: A Systematic Review and Meta-Analysis

    PubMed Central

    Camacho, Macario; Riaz, Muhammad; Capasso, Robson; Ruoff, Chad M.; Guilleminault, Christian; Kushida, Clete A.; Certal, Victor

    2015-01-01

    Background: The relationship between nasal surgery and its effect on continuous positive airway pressure (CPAP) device therapeutic treatment pressures and CPAP device use has not been previously systematically examined. Study Objectives: To conduct a systematic review and meta-analysis evaluating the effect of isolated nasal surgery on therapeutic CPAP device pressures and use in adults with obstructive sleep apnea. Methods: MEDLINE, Scopus, Web of Science, and The Cochrane Library were searched through July 15, 2014. The MOOSE consensus statement and PRISMA statement were followed. Results: Eighteen studies (279 patients) reported CPAP data after isolated nasal surgery. Seven studies (82 patients) reported preoperative and postoperative mean therapeutic CPAP device pressures and standard deviations, which reduced from 11.6 ± 2.2 to 9.5 ± 2.0 centimeters of water pressure (cwp) after nasal surgery. Pooled random effects analysis demonstrated a statistically significant pressure reduction, with a mean difference of −2.66 cwp (95% confidence intervals, −3.65 to −1.67); P < 0.00001. Eleven studies (153 patients) described subjective, self-reported data for CPAP use; and a subgroup analysis demonstrated that 89.1% (57 of 64 patients) who were not using CPAP prior to nasal surgery subsequently accepted, adhered to, or tolerated it after nasal surgery. Objective, device meter-based hours of use increased in 33 patients from 3.0 ± 3.1 to 5.5 ± 2.0 h in the short term (< 6 mo of follow-up). Conclusion: Isolated nasal surgery in patients with obstructive sleep apnea and nasal obstruction reduces therapeutic CPAP device pressures and the currently published literature's objective and subjective data consistently suggest that it also increases CPAP use in select patients. Citation: Camacho M, Riaz M, Capasso R, Ruoff CM, Guilleminault C, Kushida CA, Certal V. The effect of nasal surgery on continuous positive airway pressure device use and therapeutic treatment

  13. The effect of short-term withdrawal from continuous positive airway pressure therapy on sympathetic activity and markers of vascular inflammation in subjects with obstructive sleep apnoea.

    PubMed

    Phillips, Craig L; Yang, Qiao; Williams, Andrew; Roth, Michael; Yee, Brendon J; Hedner, Jan A; Berend, Norbert; Grunstein, Ronald R

    2007-06-01

    Obstructive sleep apnoea (OSA) is commonly associated with cardiovascular disease and sympathetic activation. However, it is unclear whether this association is independent of obesity and to what extent treatment with nasal continuous positive airway pressure (CPAP) alleviates the vascular inflammation that underpins cardiovascular disease. We therefore evaluated whether short-term withdrawal from CPAP therapy in subjects with moderate-severe OSA would result in increased levels of sympathetic activity and circulating inflammatory cytokines independent of weight. Vascular inflammatory markers (hsCRP, hsIL-6 and hsTNF-alpha) were assessed in 20 subjects after one and seven nights of withdrawal from CPAP together with the hypoxia-responsive angiogenic marker VEGF and urinary catecholamines. Compared with baseline on CPAP, withdrawal from therapy resulted in an immediate return of OSA with an increase in RDI to 26.7 +/- 5.2 and 39.0 +/- 5.9 events per hour after one and seven nights without CPAP, respectively (both P < 0.0001). This was accompanied by a concomitant rise in daytime urinary noradrenaline (P < 0.0001) after seven nights CPAP withdrawal that was positively associated with the severity of hypoxaemia. In contrast, withdrawal from CPAP therapy was not accompanied by any change in measured cytokines or VEGF (all P > 0.1). In conclusion, 1 week of CPAP withdrawal was associated with a return of OSA and a marked increase in sympathetic activity without a concomitant elevation of vascular inflammatory markers.

  14. Early versus delayed initiation of nasal continuous positive airway pressure for treatment of respiratory distress syndrome in premature newborns: A randomized clinical trial

    PubMed Central

    Badiee, Zohreh; Naseri, Fatemeh; Sadeghnia, Alireza

    2013-01-01

    Background: This prospective study was performed to identify whether the early use of nasal continuous positive airway pressure (n CPAP) would reduce the rate of endotracheal intubation, mechanical ventilation and surfactant administration. Materials and Methods: This study was conducted from June 2009 to September 2010 in the Shahid Beheshti University Hospital, Isfahan-Iran. A total of 72 preterm infants with 25-30 weeks gestation who needed respiratory support at 5 min after birth entered the study. Infants were randomly assigned to the very early CPAP (initiated 5 min after birth) or to the late CPAP (initiated 30 min after birth) treatment groups. The primary outcomes were need for intubation and mechanical ventilation during the first 48 h after birth and secondary outcomes were death, pneumothorax, intraventricular hemorrhage, duration of mechanical ventilation and bronchopulmonary dysplasia. Results: There were no significant differences between the two groups with regard to mortality rate, bronchopulmonary dysplasia and patent ductus arteriosus. The need for surfactant administration was significantly reduced in the early CPAP group (P = 0.04). Infants in the early CPAP group less frequently required intubation and mechanical ventilation. Conclusions: Early n CPAP is more effective than late n CPAP for the treatment of respiratory distress syndrome. In addition, the early use of n CPAP would reduce the need for some invasive procedures such as intubation and mechanical ventilation. PMID:23930249

  15. Continuous Positive Airway Pressure Treatment: Effect on Serum Lipids in Patients with Obstructive Sleep Apnoea

    PubMed Central

    Michailidis, Vassileios; Steiropoulos, Paschalis; Nena, Evangelia; Papanas, Nikolaos; Maltezos, Efstratios; Bouros, Demosthenes

    2011-01-01

    Obstructive Sleep Apnoea (OSA) is a common disorder in adults. Its hallmark is repetitive episodes of partial or complete obstruction of the upper airway during sleep associated with increasing respiratory efforts. This leads to oxyhaemoglobin desaturation, sleep fragmentation, and daytime symptoms, mainly excessive sleepiness. Accumulating evidence suggests that intermittent hypoxia and oxyhaemoglobin desaturation may, irrespective of obesity, lead to elevation of serum lipids even in non-dyslipidaemic OSA patients. Continuous Positive Airway Pressure (CPAP) is the treatment of choice for OSA, since it eliminates upper airway collapse during sleep and improves sleep fragmentation, daytime symptoms and quality of life. Moreover, it has been proposed that the amelioration of breathing disturbances during sleep can improve several markers of the lipid profile, such as total cholesterol, triglycerides, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol as well as apolipoproteins A, B and C. Indeed, some studies have reported improvements in these parameters especially in CPAP adherent patients. However, other studies failed to confirm this beneficial effect. The present article reviews the issue whether CPAP treatment exerts a beneficial effect on lipids. PMID:22216063

  16. Continuous positive airway pressure treatment: effect on serum lipids in patients with obstructive sleep apnoea.

    PubMed

    Michailidis, Vassileios; Steiropoulos, Paschalis; Nena, Evangelia; Papanas, Nikolaos; Maltezos, Efstratios; Bouros, Demosthenes

    2011-01-01

    Obstructive Sleep Apnoea (OSA) is a common disorder in adults. Its hallmark is repetitive episodes of partial or complete obstruction of the upper airway during sleep associated with increasing respiratory efforts. This leads to oxyhaemoglobin desaturation, sleep fragmentation, and daytime symptoms, mainly excessive sleepiness. Accumulating evidence suggests that intermittent hypoxia and oxyhaemoglobin desaturation may, irrespective of obesity, lead to elevation of serum lipids even in non-dyslipidaemic OSA patients. Continuous Positive Airway Pressure (CPAP) is the treatment of choice for OSA, since it eliminates upper airway collapse during sleep and improves sleep fragmentation, daytime symptoms and quality of life. Moreover, it has been proposed that the amelioration of breathing disturbances during sleep can improve several markers of the lipid profile, such as total cholesterol, triglycerides, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol as well as apolipoproteins A, B and C. Indeed, some studies have reported improvements in these parameters especially in CPAP adherent patients. However, other studies failed to confirm this beneficial effect. The present article reviews the issue whether CPAP treatment exerts a beneficial effect on lipids. PMID:22216063

  17. Continuous positive airway pressure therapy reduces oxidative stress markers and blood pressure in sleep apnea-hypopnea syndrome patients.

    PubMed

    Murri, Mora; García-Delgado, Regina; Alcázar-Ramírez, José; Fernández de Rota, Luis; Fernández-Ramos, Ana; Cardona, Fernando; Tinahones, Francisco J

    2011-12-01

    Sleep apnea-hypopnea syndrome (SAHS) is characterized by recurrent episodes of hypoxia/reoxygenation, which seems to promote oxidative stress. SAHS patients experience increases in hypertension, obesity and insulin resistance (IR). The purpose was to evaluate in SAHS patients the effects of 1 month of treatment with continuous positive airway pressure (CPAP) on oxidative stress and the association between oxidative stress and insulin resistance and blood pressure (BP). Twenty-six SAHS patients requiring CPAP were enrolled. Measurements were recorded before and 1 month after treatment. Cellular oxidative stress parameters were notably decreased after CPAP. Intracellular glutathione and mitochondrial membrane potential increased significantly. Also, total antioxidant capacity and most of the plasma antioxidant activities increased significantly. Significant decreases were seen in BP. Negative correlations were observed between SAHS severity and markers of protection against oxidative stress. BP correlated with oxidative stress markers. In conclusion, we observed an obvious improvement in oxidative stress and found that it was accompanied by an evident decrease in BP with no modification in IR. Consequently, we believe that the decrease in oxidative stress after 1 month of CPAP treatment in these patients is not contributing much to IR genesis, though it could be related to the hypertension etiology.

  18. Effect of Nasal Obstruction on Continuous Positive Airway Pressure Treatment: Computational Fluid Dynamics Analyses

    PubMed Central

    Wakayama, Tadashi; Suzuki, Masaaki; Tanuma, Tadashi

    2016-01-01

    Objective Nasal obstruction is a common problem in continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea and limits treatment compliance. The purpose of this study is to model the effects of nasal obstruction on airflow parameters under CPAP using computational fluid dynamics (CFD), and to clarify quantitatively the relation between airflow velocity and pressure loss coefficient in subjects with and without nasal obstruction. Methods We conducted an observational cross-sectional study of 16 Japanese adult subjects, of whom 9 had nasal obstruction and 7 did not (control group). Three-dimensional reconstructed models of the nasal cavity and nasopharynx with a CPAP mask fitted to the nostrils were created from each subject’s CT scans. The digital models were meshed with tetrahedral cells and stereolithography formats were created. CPAP airflow simulations were conducted using CFD software. Airflow streamlines and velocity contours in the nasal cavities and nasopharynx were compared between groups. Simulation models were confirmed to agree with actual measurements of nasal flow rate and with pressure and flow rate in the CPAP machine. Results Under 10 cmH2O CPAP, average maximum airflow velocity during inspiration was 17.6 ± 5.6 m/s in the nasal obstruction group but only 11.8 ± 1.4 m/s in the control group. The average pressure drop in the nasopharynx relative to inlet static pressure was 2.44 ± 1.41 cmH2O in the nasal obstruction group but only 1.17 ± 0.29 cmH2O in the control group. The nasal obstruction and control groups were clearly separated by a velocity threshold of 13.5 m/s, and pressure loss coefficient threshold of approximately 10.0. In contrast, there was no significant difference in expiratory pressure in the nasopharynx between the groups. Conclusion This is the first CFD analysis of the effect of nasal obstruction on CPAP treatment. A strong correlation between the inspiratory pressure loss coefficient and maximum airflow

  19. Cost-effectiveness of continuous positive airway pressure therapy in patients with obstructive sleep apnea-hypopnea in British Columbia

    PubMed Central

    Tan, MCY; Ayas, NT; Mulgrew, A; Cortes, L; FitzGerald, JM; Fleetham, JA; Schulzer, M; Ryan, CF; Ghaeli, R; Cooperx, P; Marra, CA

    2008-01-01

    BACKGROUND: Obstructive sleep apnea-hypopnea (OSAH) is a common disorder characterized by recurrent collapse of the upper airway during sleep. Patients experience a reduced quality of life and an increased risk of motor vehicle crashes (MVCs). Continuous positive airway pressure (CPAP), which is the first-line therapy for OSAH, improves sleepiness, vigilance and quality of life. OBJECTIVE: To assess the cost-effectiveness of CPAP therapy versus no treatment for OSAH patients who are drivers. METHODS: A Markov decision analytical model with a five-year time horizon was used. The study population consisted of male and female patients, between 30 and 59 years of age, who were newly diagnosed with moderate to severe OSAH. The model evaluated the cost-effectiveness of CPAP therapy in reducing rates of MVCs and improving quality of life. Utility values were obtained from previously published studies. Rates of MVCs under the CPAP and no CPAP scenarios were calculated from Insurance Corporation of British Columbia data and a systematic review of published studies. MVCs, equipment and physician costs were obtained from the British Columbia Medical Association, published cost-of-illness studies and the price lists of established vendors of CPAP equipment in British Columbia. Findings were examined from the perspectives of a third-party payer and society. RESULTS: From the third-party payer perspective, CPAP therapy was more effective but more costly than no CPAP (incremental cost-effectiveness ratio [ICER] of $3,626 per quality-adjusted life year). From the societal perspective, the ICER was similar ($2,979 per quality-adjusted life year). The ICER was most dependent on preference elicitation method used to obtain utility values, varying almost sixfold under alternative assumptions from the base-case analysis. CONCLUSION: After considering costs and impact on quality of life, as well as the risk of MVCs in individuals with OSAH, CPAP therapy for OSAH patients is a highly

  20. CPAP Tips

    MedlinePlus

    ... views 13:44 Airing: the first hoseless, maskless, micro-CPAP by Three P's Entertainment - Duration: 4:39. ... 604 views 4:37 Airing: The world's first micro- CPAP for sleep apnea - Duration: 4:26. Airing ...

  1. [Non-CPAP therapies in obstructive sleep apnoea: an overview].

    PubMed

    Keymel, S; Kelm, M; Randerath, W J

    2013-01-01

    Optimal treatment of the obstructive sleep apnoea syndrome (OSAS) requires an individually designed and interdisciplinary approach. Continuous positive airway pressure (CPAP) is accepted as the first line therapy for patients with OSAS. However, non-CPAP therapies may be indicated as supportive therapeutical approach in CPAP failure or as an alternative approach in CPAP intolerance. Overall, the level of evidence for the majority of non-CPAP therapies is low. Mandibular advancement devices as a medical non-CPAP treatment have proven to reduce respiratory disturbances to a level which may be sufficient in mild to moderate sleep apnoea. Apnoea triggered neurostimulation of upper airway muscles is an innovative approach that has shown promising results in preclinical studies. Surgical treatment has previously been performed as single level surgery of the nasal, the oropharyngeal or hypopharyngeal level. However, only tonsillectomy in the presence of tonsillar hypertrophy and maxillomandibular advancement are recommended in carefully selected cases. Due to low success rates for single level surgery, multilevel surgery has been proposed as the surgical approach for the future.

  2. Development and validation of a simple algorithm for initiation of CPAP in neonates with respiratory distress in Malawi

    PubMed Central

    Hundalani, Shilpa G; Richards-Kortum, Rebecca; Oden, Maria; Kawaza, Kondwani; Gest, Alfred; Molyneux, Elizabeth

    2015-01-01

    Background Low-cost bubble continuous positive airway pressure (bCPAP) systems have been shown to improve survival in neonates with respiratory distress, in developing countries including Malawi. District hospitals in Malawi implementing CPAP requested simple and reliable guidelines to enable healthcare workers with basic skills and minimal training to determine when treatment with CPAP is necessary. We developed and validated TRY (T: Tone is good, R: Respiratory Distress and Y=Yes) CPAP, a simple algorithm to identify neonates with respiratory distress who would benefit from CPAP. Objective To validate the TRY CPAP algorithm for neonates with respiratory distress in a low-resource setting. Methods We constructed an algorithm using a combination of vital signs, tone and birth weight to determine the need for CPAP in neonates with respiratory distress. Neonates admitted to the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi, were assessed in a prospective, cross-sectional study. Nurses and paediatricians-in-training assessed neonates to determine whether they required CPAP using the TRY CPAP algorithm. To establish the accuracy of the TRY CPAP algorithm in evaluating the need for CPAP, their assessment was compared with the decision of a neonatologist blinded to the TRY CPAP algorithm findings. Results 325 neonates were evaluated over a 2-month period; 13% were deemed to require CPAP by the neonatologist. The inter-rater reliability with the algorithm was 0.90 for nurses and 0.97 for paediatricians-in-training using the neonatologist's assessment as the reference standard. Conclusions The TRY CPAP algorithm has the potential to be a simple and reliable tool to assist nurses and clinicians in identifying neonates who require treatment with CPAP in low-resource settings. PMID:25877290

  3. A Cost-Effectiveness Analysis of Surgery for Middle-Aged Men with Severe Obstructive Sleep Apnea Intolerant of CPAP

    PubMed Central

    Tan, Kelvin B.; Toh, Song Tar; Guilleminault, Christian; Holty, Jon-Erik C.

    2015-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is associated with increased cardiovascular morbidity and mortality. Conventional OSA therapy necessitates indefinite continuous positive airway pressure (CPAP). Although CPAP is an effective treatment modality, up to 50% of OSA patients are intolerant of CPAP. We explore whether surgical modalities developed for those intolerant of CPAP are cost-effective. Methods: We construct a lifetime semi-Markov model of OSA that accounts for observed increased risks of stroke, cardiovascular disease, and motor vehicle collisions for a 50-year-old male with untreated severe OSA. Using this model, we compare the cost-effectiveness of (1) no treatment, (2) CPAP only, and (3) CPAP followed by surgery (either palatopharyngeal reconstructive surgery [PPRS] or multilevel surgery [MLS]) for those intolerant to CPAP. Results: Compared with the CPAP only strategy, CPAP followed by PPRS (CPAP-PPRS) adds 0.265 quality adjusted life years (QALYs) for an increase of $2,767 (discounted 2010 dollars) and is highly cost effective with an incremental cost-effectiveness ratio (ICER) of $10,421/QALY for a 50-year-old male with severe OSA. Compared to a CPAP-PPRS strategy, the CPAP-MLS strategy adds 0.07 QALYs at an increase of $6,213 for an ICER of $84,199/QALY. The CPAP-PPRS strategy appears cost-effective over a wide range of parameter estimates. Conclusions: Palatopharyngeal reconstructive surgery appears cost-effective in middle-aged men with severe OSA intolerant of CPAP. Further research is warranted to better define surgical candidacy as well as short-term and long-term surgical outcomes. Commentary: A commentary on this article appears in this issue on page 509. Citation: Tan KB, Toh ST, Guilleminault C, Holty JE. A cost-effectiveness analysis of surgery for middle-aged men with severe obstructive sleep apnea intolerant of CPAP. J Clin Sleep Med 2015;11(5):525–535. PMID:25700871

  4. Does the use of primary continuous positive airway pressure reduce the need for intubation and mechanical ventilation in infants ≤32 weeks’ gestation?

    PubMed Central

    Yee, Wendy H; Scotland, Jeanne; Pham, Yung; Finch, Robert

    2011-01-01

    BACKGROUND: Ventilator-induced lung injury is a recognized risk factor for bronchopulmonary dysplasia. OBJECTIVE: To determine whether primary continuous positive airway pressure (CPAP), defined as CPAP without previous endotracheal intubation for any indication, can reduce the need for intubation and mechanical ventilation in infants born at ≤32 weeks’ gestational age. METHODS: The literature was reviewed using the methodology for systematic reviews for the Consensus on Resuscitation Science adapted from the American Heart Association’s International Liaison Committee on Resuscitation. RESULTS: Fourteen studies were reviewed. Eleven studies provided varying degrees of supportive evidence (level of evidence 3 to 4) that the use of primary CPAP can reduce the need for intubation and mechanical ventilation. CONCLUSION: The use of CPAP as a primary intervention and mode of respiratory support is an option for infants ≤32 weeks’ gestation, but avoidance of intubation and mechanical ventilation is more likely in mature infants >27 weeks’ gestation. PMID:23204903

  5. Very Preterm Infants Failing CPAP Show Signs of Fatigue Immediately after Birth

    PubMed Central

    Siew, Melissa L.; van Vonderen, Jeroen J.; Hooper, Stuart B.; te Pas, Arjan B.

    2015-01-01

    Objective To investigate the differences in breathing pattern and effort in infants at birth who failed or succeeded on continuous positive airway pressure (CPAP) during the first 48 hours after birth. Methods Respiratory function recordings of 32 preterm infants were reviewed of which 15 infants with a gestational age of 28.6 (0.7) weeks failed CPAP and 17 infants with a GA of 30.1 (0.4) weeks did not fail CPAP. Frequency, duration and tidal volumes (VT) of expiratory holds (EHs), peak inspiratory flows, CPAP-level and FiO2-levels were analysed. Results EH incidence increased <6 minutes after birth and remained stable thereafter. EH peak inspiratory flows and VT were similar between CPAP-fail and CPAP-success infants. At 9-12 minutes, CPAP-fail infants more frequently used smaller VTs, 0-9 ml/kg and required higher peak inspiratory flows. However, CPAP-success infants often used large VTs (>9 ml/kg) with higher peak inspiratory flows than CPAP-fail infants (71.8 ± 15.8 vs. 15.5 ± 5.2 ml/kg.s, p <0.05). CPAP-fail infants required higher FiO2 (0.31 ± 0.03 vs. 0.21 ± 0.01), higher CPAP pressures (6.62 ± 0.3 vs. 5.67 ± 0.26 cmH2O) and more positive pressure-delivered breaths (45 ± 12 vs. 19 ± 9%) (p <0.05) Conclusion At 9-12 minutes after birth, CPAP-fail infants more commonly used lower VTs and required higher peak inspiratory flow rates while receiving greater respiratory support. VT was less variable and larger VT was infrequently used reflecting early signs of fatigue. PMID:26052947

  6. Novel and emerging nonpositive airway pressure therapies for sleep apnea.

    PubMed

    Park, John G; Morgenthaler, Timothy M; Gay, Peter C

    2013-12-01

    CPAP therapy has remained the standard of care for the treatment of sleep apnea for nearly 4 decades. Its overall effectiveness, however, has been limited by incomplete adherence despite many efforts to improve comfort. Conventional alternative therapies include oral appliances and upper airway surgeries. Recently, several innovative alternatives to CPAP have been developed. These novel approaches include means to increase arousal thresholds, electrical nerve stimulation, oral vacuum devices, and nasal expiratory resistive devices. We will review the physiologic mechanisms and the current evidence for these novel treatments.

  7. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea*

    PubMed Central

    de Andrade, Rafaela Garcia Santos; Piccin, Vivien Schmeling; Nascimento, Juliana Araújo; Viana, Fernanda Madeiro Leite; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2014-01-01

    Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect. PMID:25610507

  8. Selective indication for positive airway pressure (PAP) in sleep-related breathing disorders with obstruction

    PubMed Central

    Stasche, Norbert

    2006-01-01

    Positive airway pressure (PAP) is the therapy of choice for most sleep-related breathing disorders (SRBD). A variety of PAP devices using positive airway pressure (CPAP, BiPAP, APAP, ASV) must be carefully considered before application. This overview aims to provide criteria for choosing the optimal PAP device according to severity and type of sleep-related breathing disorder. In addition, the range of therapeutic applications, constraints and side effects as well as alternative methods to PAP will be discussed. This review is based on an analysis of current literature and clinical experience. The data is presented from an ENT-sleep-laboratory perspective and is designed to help the ENT practitioner initiate treatment and provide support. Different titration methods, current devices and possible applications will be described. In addition to constant pressure devices (CPAP), most commonly used for symptomatic obstructive sleep apnoea (OSA) without complicating conditions, BiPAP models will be introduced. These allow two different positive pressure settings and are thus especially suitable for patients with cardiopulmonary diseases or patients with pressure intolerance, increasing compliance in this subgroup considerably. Compliance can also be increased in patients during first night of therapy, patients with highly variable pressure demands or position-dependent OSA, by using self-regulating Auto-adjust PAP devices (Automatic positive airway pressure, APAP). Patients with Cheyne-Stokes breathing, a subtype of central sleep apnoea, benefit from adaptive servo-ventilation (ASV), which analyzes breathing patterns continually and adjusts the actual ventilation pressure accordingly. This not only reduces daytime sleepiness, but can also influence heart disease positively. Therapy with positive airway pressure is very effective in eliminating obstruction-related sleep diseases and symptoms. However, because therapy is generally applied for life, the optimal PAP device

  9. In patients with minimally symptomatic OSA can baseline characteristics and early patterns of CPAP usage predict those who are likely to be longer-term users of CPAP

    PubMed Central

    Bratton, Daniel J.; Craig, Sonya E.; Kohler, Malcolm; Stradling, John R.

    2016-01-01

    Background Long-term continuous positive airway pressure (CPAP) usage varies between individuals. It would be of value to be able to identify those who are likely to benefit from CPAP (and use it long term), versus those who would not, and might therefore benefit from additional help early on. First, we explored whether baseline characteristics predicted CPAP usage in minimally symptomatic obstructive sleep apnoea (OSA) patients, a group who would be expected to have low usage. Second, we explored if early CPAP usage was predictive of longer-term usage, as has been shown in more symptomatic OSA patients. Methods The MOSAIC trial was a multi-centre randomised controlled trial where minimally symptomatic OSA patients were randomised to CPAP, or standard care, for 6 months. Here we have studied only those patients randomised to CPAP treatment. Baseline characteristics including symptoms, questionnaires [including the Epworth sleepiness score (ESS)] and sleep study parameters were recorded. CPAP usage was recorded at 2–4 weeks after initiation and after 6 months. The correlation and association between baseline characteristics and 6 months CPAP usage was assessed, as was the correlation between 2 and 4 weeks CPAP usage and 6 months CPAP usage. Results One hundred and ninety-five patients randomised to CPAP therapy had median [interquartile range (IQR)] CPAP usage of 2:49 (0:44, 5:13) h:min/night (h/n) at the 2–4 weeks visit, and 2:17 (0:08, 4:54) h/n at the 6 months follow-up visit. Only male gender was associated with increased long-term CPAP use (male usage 2:56 h/n, female 1:57 h/n; P=0.02). There was a moderate correlation between the usage of CPAP at 2–4 weeks and 6 months, with about 50% of the variability in long-term use being predicted by the short-term use. Conclusions In patients with minimally symptomatic OSA, our study has shown that male gender (and not OSA severity or symptom burden) is associated with increased long-term use of CPAP at 6 months

  10. Withdrawal of Continuous Positive Airway Pressure Therapy after Malar Advancement and Le Fort II Distraction in a Case of Apert Syndrome with Obstructive Sleep Apnea

    PubMed Central

    Onda, Nobuto; Chiba, Shintaro; Moriwaki, Hiroto; Sawai, Rika; Yoshigoe, Akira; Watanabe, Subaru; Ando, Yuji; Uchida, Ryo; Miyawaki, Takeshi; Wada, Kota

    2015-01-01

    Apert syndrome is a congenital syndrome characterized by craniosynostosis and craniofacial dysostosis, among other features, and is reported to cause obstructive sleep apnea (OSA) because of upper airway narrowing associated with midfacial dysplasia. We recently encountered a case involving a patient with Apert syndrome complicated by OSA who began to receive continuous positive airway pressure (CPAP) therapy at the age of 4. OSA resolved after maxillofacial surgery performed at the age of 11, and CPAP was eventually withdrawn. In pediatric patients with maxillofacial dysplasia complicated by OSA, a long-term treatment plan including CPAP in addition to maxillofacial plastic and reconstructive surgery should be considered in view of the effects of OSA on growth. PMID:26473084

  11. Predictors of Long-Term Adherence to Continuous Positive Airway Pressure Therapy in Patients with Obstructive Sleep Apnea and Cardiovascular Disease in the SAVE Study

    PubMed Central

    Chai-Coetzer, Ching Li; Luo, Yuan-Ming; Antic, Nick A.; Zhang, Xi-Long; Chen, Bao-Yuan; He, Quan-Ying; Heeley, Emma; Huang, Shao-Guang; Anderson, Craig; Zhong, Nan-Shan; McEvoy, R. Doug

    2013-01-01

    Study Objectives: To determine the clinical variables that best predict long- term continuous positive airway pressure (CPAP) adherence among patients with cardiovascular disease who have obstructive sleep apnea (OSA). Design: 12-mo prospective within-trial observational study. Setting: Centers in China, Australia, and New Zealand participating in the Sleep Apnea cardioVascular Endpoints (SAVE) study. Patients: There were 275 patients age 45-70 y with cardiovascular disease (i.e., previously documented transient ischemic attack, stroke, or coronary artery disease) and OSA (4% oxygen desaturation index (ODI) > 12) who were randomized into the CPAP arm of the SAVE trial prior to July 1, 2010. Methods: Age, sex, country of residence, type of cardiovascular disease, baseline ODI, severity of sleepiness, and Hospital Anxiety and Depression Scale (HADS) scores plus CPAP side effects and adherence at 1 mo were entered in univariate analyses in an attempt to identify factors predictive of CPAP adherence at 12 mo. Variables with P < 0.2 were then included in a multivariate analysis using a linear mixed model with sites as a random effect and 12-mo CPAP use as the dependent outcome variable. Measurements and Results: CPAP adherence at 1, 6, and 12 mo was (mean ± standard deviation) 4.4 ± 2.0, 3.8 ± 2.3, and 3.3 ± 2.4 h/night, respectively. CPAP use at 1 mo (effect estimate ± standard error, 0.65 ± 0.07 per h increase, P < 0.001) and side effects at 1 mo (-0.24 ± 0.092 per additional side effect, P = 0.009) were the only independent predictors of 12- mo CPAP adherence. Conclusion: Continuous positive airway pressure use in patients with coexisting cardiovascular disease and moderate to severe obstructive sleep apnea decreases significantly over 12 months. This decline can be predicted by early patient experiences with continuous positive airway pressure (i.e., adherence and side effects at 1 month), raising the possibility that intensive early interventions could

  12. Effects of 12 Months Continuous Positive Airway Pressure on Sympathetic Activity Related Brainstem Function and Structure in Obstructive Sleep Apnea.

    PubMed

    Henderson, Luke A; Fatouleh, Rania H; Lundblad, Linda C; McKenzie, David K; Macefield, Vaughan G

    2016-01-01

    Muscle sympathetic nerve activity (MSNA) is greatly elevated in patients with obstructive sleep apnea (OSA) during normoxic daytime wakefulness. Increased MSNA is a precursor to hypertension and elevated cardiovascular morbidity and mortality. However, the mechanisms underlying the high MSNA in OSA are not well understood. In this study we used concurrent microneurography and magnetic resonance imaging to explore MSNA-related brainstem activity changes and anatomical changes in 15 control and 15 OSA subjects before and after 6 and 12 months of continuous positive airway pressure (CPAP) treatment. We found that following 6 and 12 months of CPAP treatment, resting MSNA levels were significantly reduced in individuals with OSA. Furthermore, this MSNA reduction was associated with restoration of MSNA-related brainstem activity and structural changes in the medullary raphe, rostral ventrolateral medulla, dorsolateral pons, and ventral midbrain. This restoration occurred after 6 months of CPAP treatment and was maintained following 12 months CPAP. These findings show that continual CPAP treatment is an effective long-term treatment for elevated MSNA likely due to its effects on restoring brainstem structure and function. PMID:27013952

  13. Effects of 12 Months Continuous Positive Airway Pressure on Sympathetic Activity Related Brainstem Function and Structure in Obstructive Sleep Apnea

    PubMed Central

    Henderson, Luke A.; Fatouleh, Rania H.; Lundblad, Linda C.; McKenzie, David K.; Macefield, Vaughan G.

    2016-01-01

    Muscle sympathetic nerve activity (MSNA) is greatly elevated in patients with obstructive sleep apnea (OSA) during normoxic daytime wakefulness. Increased MSNA is a precursor to hypertension and elevated cardiovascular morbidity and mortality. However, the mechanisms underlying the high MSNA in OSA are not well understood. In this study we used concurrent microneurography and magnetic resonance imaging to explore MSNA-related brainstem activity changes and anatomical changes in 15 control and 15 OSA subjects before and after 6 and 12 months of continuous positive airway pressure (CPAP) treatment. We found that following 6 and 12 months of CPAP treatment, resting MSNA levels were significantly reduced in individuals with OSA. Furthermore, this MSNA reduction was associated with restoration of MSNA-related brainstem activity and structural changes in the medullary raphe, rostral ventrolateral medulla, dorsolateral pons, and ventral midbrain. This restoration occurred after 6 months of CPAP treatment and was maintained following 12 months CPAP. These findings show that continual CPAP treatment is an effective long-term treatment for elevated MSNA likely due to its effects on restoring brainstem structure and function. PMID:27013952

  14. A High-Value, Low-Cost Bubble Continuous Positive Airway Pressure System for Low-Resource Settings: Technical Assessment and Initial Case Reports

    PubMed Central

    Brown, Jocelyn; Machen, Heather; Kawaza, Kondwani; Mwanza, Zondiwe; Iniguez, Suzanne; Lang, Hans; Gest, Alfred; Kennedy, Neil; Miros, Robert; Richards-Kortum, Rebecca; Molyneux, Elizabeth; Oden, Maria

    2013-01-01

    Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design—consumer-grade pumps, medical tubing, and regulators—it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device. PMID:23372661

  15. Investigating Reasons for CPAP Adherence in Adolescents: A Qualitative Approach

    PubMed Central

    Prashad, Priya S.; Marcus, Carole L.; Maggs, Jill; Stettler, Nicolas; Cornaglia, Mary A.; Costa, Priscilla; Puzino, Kristina; Xanthopoulos, Melissa; Bradford, Ruth; Barg, Frances K.

    2013-01-01

    Study Objectives: Adolescents with obstructive sleep apnea syndrome (OSAS) represent an important but understudied subgroup of long-term continuous positive airway pressure (CPAP) users. The purpose of this qualitative study was to identify factors related to adherence from the perspective of adolescents and their caregivers. Methods: Individual open-ended, semi-structured interviews were conducted with adolescents (n = 21) and caregivers (n = 20). Objective adherence data from the adolescents' CPAP machines during the previous month was obtained. Adolescents with different adherence levels and their caregivers were asked their views on CPAP. Using a modified grounded theory approach, we identified themes and developed theories that explained the adolescents' adherence patterns. Results: Adolescent participants (n = 21) were aged 12-18 years, predominantly male (n = 15), African American (n = 16), users of CPAP for at least one month. Caregivers were mainly mothers (n = 17). Seven adolescents had high use (mean use 381 ± 80 min per night), 7 had low use (mean use 30 ± 24 min per night), and 7 had no use during the month prior to being interviewed. Degree of structure in the home, social reactions, mode of communication among family members, and perception of benefits were issues that played a role in CPAP adherence. Conclusions: Understanding the adolescent and family experience of using CPAP may be key to increasing adolescent CPAP adherence. As a result of our findings, we speculate that health education, peer support groups, and developmentally appropriate individualized support strategies may be important in promoting adherence. Future studies should examine these theories of CPAP adherence. Citation: Prashad PS; Marcus CL; Maggs J; Stettler N; Cornaglia MA; Costa P; Puzino K; Xanthopoulos M; Bradford R; Barg FK. Investigating reasons for CPAP adherence in adolescents: a qualitative approach. J Clin Sleep Med 2013;9(12):1303-1313. PMID:24340293

  16. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    SciTech Connect

    Goldstein, Jeffrey D.; Lawrence, Yaacov R.; Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader; Segel, Michael J.; Peled, Nir; Symon, Zvi

    2015-10-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.

  17. Trends in use of neonatal CPAP: a population-based study

    PubMed Central

    2011-01-01

    Background Continuous positive airway pressure (CPAP) is used widely to provide respiratory support for neonates, and is often the first treatment choice in tertiary centres. Recent trials have demonstrated that CPAP reduces need for intubation and ventilation for infants born at 25-28 weeks gestation, and at > 32weeks, in non-tertiary hospitals, CPAP reduces need for transfer to NICU. The aim of this study was to examine recent population trends in the use of neonatal continuous positive airway pressure. Methods We undertook a population-based cohort study of all 696,816 liveborn neonates ≥24 weeks gestation in New South Wales (NSW) Australia, 2001-2008. Data were obtained from linked birth and hospitalizations records, including neonatal transfers. The primary outcome was CPAP without mechanical ventilation (via endotracheal intubation) between birth and discharge from the hospital system. Analyses were stratified by age ≤32 and > 32 weeks gestation. Results Neonates receiving any ventilatory support increased from 1,480 (17.9/1000) in 2001 to 2,486 (26.9/1000) in 2008, including 461 (5.6/1000) to 1,465 (15.8/1000) neonates who received CPAP alone. There was a concurrent decrease in mechanical ventilation use from 12.3 to 11.0/1000. The increase in CPAP use was greater among neonates > 32 weeks (from 3.2 to 11.8/1000) compared with neonates ≤32 weeks (from 18.1 to 32.7/1000). The proportion of CPAP > 32 weeks initiated in non-tertiary hospitals increased from 6% to 30%. Conclusions The use of neonatal CPAP is increasing, especially > 32 weeks gestation and among non-tertiary hospitals. Recommendations are required regarding which infants should be considered for CPAP, resources necessary for a unit to offer CPAP and monitoring of longer term outcomes. PMID:21999325

  18. New developments in the use of positive airway pressure for obstructive sleep apnea

    PubMed Central

    Boeder, Schafer; Malhotra, Atul; Patel, Sanjay R.

    2015-01-01

    Obstructive sleep apnea (OSA) is a disorder which afflicts a large number of individuals around the world. OSA causes sleepiness and is a major cardiovascular risk factor. Since its inception in the early 1980’s, continuous positive airway pressure (CPAP) has emerged as the major treatment of OSA, and it has been shown to improve sleepiness, hypertension, and a number of cardiovascular indices. Despite its successes, adherence with treatment remains a major limitation. Herein we will review the evidence behind the use of positive airway pressure (PAP) therapy, its various modes, and the methods employed to improve adherence. We will also discuss the future of PAP therapy in OSA and personalization of care. PMID:26380760

  19. New developments in the use of positive airway pressure for obstructive sleep apnea.

    PubMed

    Donovan, Lucas M; Boeder, Schafer; Malhotra, Atul; Patel, Sanjay R

    2015-08-01

    Obstructive sleep apnea (OSA) is a disorder which afflicts a large number of individuals around the world. OSA causes sleepiness and is a major cardiovascular risk factor. Since its inception in the early 1980's, continuous positive airway pressure (CPAP) has emerged as the major treatment of OSA, and it has been shown to improve sleepiness, hypertension, and a number of cardiovascular indices. Despite its successes, adherence with treatment remains a major limitation. Herein we will review the evidence behind the use of positive airway pressure (PAP) therapy, its various modes, and the methods employed to improve adherence. We will also discuss the future of PAP therapy in OSA and personalization of care. PMID:26380760

  20. Nurse-led intensive interventions improve adherence to continuous positive airway pressure therapy and quality of life in obstructive sleep apnea patients

    PubMed Central

    Chen, Xiaofen; Chen, Weiting; Hu, Weijie; Huang, Kui; Huang, Jing; Zhou, Yu

    2015-01-01

    Background Continuous positive airway pressure (CPAP) is widely recommended for the treatment of sleep apnea/hypopnea syndrome (SAHS), but its usage by patients is very low. The aim of this study was to assess intensive educational programs and nursing support for the improvement of CPAP use and outcomes in SAHS patients. Methods Eighty new SAHS patients were randomized to receive nurse-led intensive interventions or usual support at hospital and home. The main outcome measure was CPAP use; changes in sleeping, symptoms, mood, and quality of life were also assessed after 12 months of treatment. Results All outcome measures were improved after treatment in both groups. However, patients receiving intensive support with significantly higher CPAP use (higher daily CPAP usage by 2.2 hours/day) had greater improvements in SAHS symptoms and mood (P<0.05). The intervention group further showed an improvement in the Short Form-36 domains of mental and physical health (P<0.05). Conclusion The CPAP usage and quality of life can be significantly improved by nurse-led intensive program in obstructive sleep apnea patients. PMID:26648703

  1. Safety and effectiveness of bubble continuous positive airway pressure in preterm neonates with respiratory distress

    PubMed Central

    Mathai, S.S.; Rajeev, A.; Adhikari, K.M.

    2014-01-01

    Background Studies on Bubble Continuous Positive Airway Pressure (B-CPAP) as respiratory support for neonates are few. The aim of our study was to determine the efficacy and safety of B-CPAP in preterm neonates requiring respiratory support. Methods A prospective observation study was done on 50 preterm babies requiring respiratory support for mild to moderate respiratory distress. Support was given with short, nasal cannulae. Surfactant was administered when indicated. Monitoring was done clinically, with pulse oximeter, radiologically and with blood gases. Staff members were also asked their views. Follow-up was done for 3 months. Results The mean gestational age was 32.46 (+3.23) weeks and mean birth weight 1454.4 (+487.42) g. Respiratory Distress Syndrome was the commonest indication (30/50). The mean maximum pressure was 6.04 cm H2O and mean maximum FiO2 was 72.16%. Mean maximum paO2, paCO2 and mean minimum paCO2 were 92.93 mm Hg (+16.97), 52.36 mm Hg (+ 7.78) and 36.46 mm Hg (+ 4.95) respectively. Early initiation resulted in lesser duration of support. Failure rate was 30%. Apnoea, >1 dose surfactant and late initiation had a statistically higher incidence of failure. Main complications were skin abrasions (30%), feed intolerance (26%) and gastric distension (26%). Survival rate was 94%. 68% of staff felt that it was as easy to use and 88% felt it was more reliable than standard CPAP. Conclusions Bubble Continuous Positive Airway Pressure is safe, efficacious and easy to use in preterm neonates with mild to moderate respiratory distress. PMID:25382905

  2. Obstructive sleep apnea syndrome, continuous positive airway pressure and treatment of hypertension.

    PubMed

    Floras, John S

    2015-09-15

    Obstructive sleep apnea (OSA), present in ~15% of the general population, increases the risks of stroke, heart failure, and premature death. Importantly, individuals with cardiovascular disease have a higher prevalence yet they often have few symptoms to alert clinicians to its presence. OSA with an apnea-hypopnea index (AHI) ≥15 events/hour is present in ≥30% of patients with primary hypertension and in up to 80% of those with drug resistant hypertension, suggesting that the neural, hormonal, inflammatory and vascular cascades triggered by OSA may elevate blood pressure chronically. The purpose of this review is to summarize: (1) the epidemiology of OSA and its relation to cardiovascular risk; (2) potential mechanisms by which OSA could promote conditions known to increase the risk of hypertension or contribute to its development and progression; (3) evidence for and against a pro-hypertensive effect of OSA; and, (4) the impact of treatment with continuous positive airway pressure (CPAP) on blood pressure and blood pressure-related morbidities. The prevailing view that the effect of treatment on blood pressure is modest arises from the inability of most contemporary technology to measure accurately the true impact of CPAP on OSA-entrained surges in nocturnal blood pressure. Moreover the exclusive focus on blood pressure, as if this is the principal determinant of cardiovascular event rates in this population, is naïve. The capacity to reduce cardiovascular risk by treating OSA with CPAP likely transcends a simple blood pressure effect; formal testing of this hypothesis will require adequately powered randomized clinical trials.

  3. A randomised control study comparing the Infant Flow Driver with nasal continuous positive airway pressure in preterm infants

    PubMed Central

    Mazzella, M; Bellini, C; Calevo, M; Campone, F; Massocco, D; Mezzano, P; Zullino, E; Scopesi, F; Arioni, C; Bonacci, W; Serra, G

    2001-01-01

    OBJECTIVE—To compare the effectiveness of the Infant Flow Driver (IFD) with single prong nasal continuous positive airway pressure (nCPAP) in preterm neonates affected by respiratory distress syndrome.
DESIGN—Randomised controlled study.
PATIENTS—Between September 1997 and March 1999, 36 preterm infants who were eligible for CPAP treatment were randomly selected for either nCPAP or IFD and studied prospectively for changes in oxygen requirement and/or respiratory rate. The requirement for mechanical ventilation, complications of treatment, and effects on mid-term outcome were also evaluated.
RESULTS—Use of the IFD had a significantly beneficial effect on both oxygen requirement and respiratory rate (p < 0.0001) when compared with nCPAP. Moreover, O2 requirement and respiratory rate were significantly decreased by four hours (p < 0.001 and p < 0.03 respectively). The probability of remaining supplementary oxygen free over the first 48 hours of treatment was significantly higher in patients treated with the IFD than with nCPAP (p < 0.02). IFD treated patients had a higher success (weaning) rate (94% v 72%) and shorter duration of treatment (49.3 (31) v 56 (29.7) hours respectively; mean (SD)), although the difference was not significant.
CONCLUSIONS—IFD appears to be a feasible device for managing respiratory distress syndrome in preterm infants, and benefits may be had with regard to oxygen requirement and respiratory rate when compared with nCPAP. The trend towards reduced requirement for mechanical ventilation, shorter clinical recovery time, and shorter duration of treatment requires further evaluation in a multicentre randomised clinical trial.

 PMID:11517199

  4. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  5. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  6. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  7. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  8. 21 CFR 868.2600 - Airway pressure monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Airway pressure monitor. 868.2600 Section 868.2600...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2600 Airway pressure monitor. (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper...

  9. Effect of CPAP therapy on endothelial function in obstructive sleep apnoea: A systematic review and meta-analysis.

    PubMed

    Schwarz, Esther I; Puhan, Milo A; Schlatzer, Christian; Stradling, John R; Kohler, Malcolm

    2015-08-01

    Obstructive sleep apnoea (OSA) is a prevalent sleep-related breathing disorder associated with adverse cardiovascular outcome. Endothelial dysfunction is one of the proposed mechanistic links between OSA and the increased cardiovascular risk. Treatment with continuous positive airway pressure (CPAP) may reverse this detrimental pathophysiological consequence of OSA. Most studies on the effect of CPAP on endothelial function in OSA are limited by their low sample size. The objective of this systematic review was to assess the effect CPAP therapy on endothelial function in patients with OSA. We conducted a systematic review and meta-analysis searching literature databases up to August 2013 for randomized controlled trials (RCTs) on the effect of CPAP on endothelial function in OSA, assessed by flow-mediated dilatation (FMD) and other validated techniques. The primary outcome for the meta-analysis (DerSimonian/Laird random-effects method) was the treatment effect on FMD. Eight RCTs comparing the effects of therapeutic CPAP versus subtherapeutic CPAP (or no intervention) on endothelial function involving 245 OSA patients were included in the systematic review. The studies are consistent in effect direction, showing an improvement of endothelial function by CPAP. Four RCTs involving 150 patients could be used for the meta-analysis. Compared to the control group, CPAP therapy (range 2-24 weeks) significantly increased absolute % FMD by 3.87% (95% confidence interval: 1.93-5.80, P < 0.001). In patients with OSA, CPAP therapy improves endothelial function significantly and to a clinically important extent.

  10. Efficacy of Home Single-Channel Nasal Pressure for Recommending Continuous Positive Airway Pressure Treatment in Sleep Apnea

    PubMed Central

    Masa, Juan F.; Duran-Cantolla, Joaquin; Capote, Francisco; Cabello, Marta; Abad, Jorge; Garcia-Rio, Francisco; Ferrer, Antoni; Fortuna, Ana M.; Gonzalez-Mangado, Nicolas; de la Peña, Monica; Aizpuru, Felipe; Barbe, Ferran; Montserrat, Jose M.; Larrateguy, Luis D.; de Castro, Jorge Rey; Garcia-Ledesma, Estefania; Corral, Jaime; Martin-Vicente, Maria J.; Martinez-Null, Cristina; Egea, Carlos; Cancelo, Laura; García-Díaz, Emilio; Carmona-Bernal, Carmen; Sánchez-Armengol, Ángeles; Mayos, Merche; Miralda, Rosa M; Troncoso, Maria F.; Gonzalez, Monica; Martinez-Martinez, Marian; Cantalejo, Olga; Piérola, Javier; Vigil, Laura; Embid, Cristina; del Mar Centelles, Mireia; Prieto, Teresa Ramírez; Rojo, Blas; Lores, Vanesa

    2015-01-01

    Introduction: Unlike other prevalent diseases, obstructive sleep apnea (OSA) has no simple tool for diagnosis and therapeutic decision-making in primary healthcare. Home single-channel nasal pressure (HNP) may be an alternative to polysomnography for diagnosis but its use in therapeutic decisions has yet to be explored. Objectives: To ascertain whether an automatically scored HNP apnea-hypopnea index (AHI), used alone to recommend continuous positive airway pressure (CPAP) treatment, agrees with decisions made by a specialist using polysomnography and several clinical variables. Methods: Patients referred by primary care physicians for OSA suspicion underwent randomized polysomnography and HNP. We analyzed the total sample and both more and less symptomatic subgroups for Bland and Altman plots to explore AHI agreement; receiver operating characteristic curves to establish area under the curve (AUC) measurements for CPAP recommendation; and therapeutic decision efficacy for several HNP AHI cutoff points. Results: Of the 787 randomized patients, 35 (4%) were lost, 378 (48%) formed the more symptomatic and 374 (48%) the less symptomatic subgroups. AHI bias and agreement limits were 5.8 ± 39.6 for the total sample, 5.3 ± 38.7 for the more symptomatic, and 6 ± 40.2 for the less symptomatic subgroups. The AUC were 0.826 for the total sample, 0.903 for the more symptomatic, and 0.772 for the less symptomatic subgroups. In the more symptomatic subgroup, 70% of patients could be correctly treated with CPAP. Conclusion: Automatic home single-channel nasal pressure scoring can correctly recommend CPAP treatment in most of more symptomatic patients with OSA suspicion. Our results suggest that this device may be an interesting tool in initial OSA management for primary care physicians, although future studies in a primary care setting are necessary. Clinical Trials Information: Clinicaltrial.gov identifier: NCT01347398. Citation: Masa JF, Duran-Cantolla J, Capote F, Cabello

  11. Cost-effectiveness of Out-of-Hospital Continuous Positive Airway Pressure for Acute Respiratory Failure

    PubMed Central

    Thokala, Praveen; Goodacre, Steve; Ward, Matt; Penn-Ashman, Jerry; Perkins, Gavin D.

    2015-01-01

    Study objective We determine the cost-effectiveness of out-of-hospital continuous positive airway pressure (CPAP) compared with standard care for adults presenting to emergency medical services with acute respiratory failure. Methods We developed an economic model using a United Kingdom health care system perspective to compare the costs and health outcomes of out-of-hospital CPAP to standard care (inhospital noninvasive ventilation) when applied to a hypothetical cohort of patients with acute respiratory failure. The model assigned each patient a probability of intubation or death, depending on the patient’s characteristics and whether he or she had out-of-hospital CPAP or standard care. The patients who survived accrued lifetime quality-adjusted life-years (QALYs) and health care costs according to their age and sex. Costs were accrued through intervention and hospital treatment costs, which depended on patient outcomes. All results were converted into US dollars, using the Organisation for Economic Co-operation and Development purchasing power parities rates. Results Out-of-hospital CPAP was more effective than standard care but was also more expensive, with an incremental cost-effectiveness ratio of £20,514 per QALY ($29,720/QALY) and a 49.5% probability of being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold. The probability of out-of-hospital CPAP’s being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold depended on the incidence of eligible patients and varied from 35.4% when a low estimate of incidence was used to 93.8% with a high estimate. Variation in the incidence of eligible patients also had a marked influence on the expected value of sample information for a future randomized trial. Conclusion The cost-effectiveness of out-of-hospital CPAP is uncertain. The incidence of patients eligible for out-of-hospital CPAP appears to be the key determinant of cost-effectiveness. PMID:25737210

  12. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update

    PubMed Central

    Johnson, Karin Gardner; Johnson, Douglas Clark

    2015-01-01

    Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features. PMID:26604837

  13. CPAP, Weight Loss, or Both for Obstructive Sleep Apnea

    PubMed Central

    Chirinos, Julio A.; Gurubhagavatula, Indira; Teff, Karen; Rader, Daniel J.; Wadden, Thomas A.; Townsend, Raymond; Foster, Gary D.; Maislin, Greg; Saif, Hassam; Broderick, Preston; Chittams, Jesse; Hanlon, Alexandra L.; Pack, Allan I.

    2014-01-01

    BACKGROUND Obesity and obstructive sleep apnea tend to coexist and are associated with inflammation, insulin resistance, dyslipidemia, and high blood pressure, but their causal relation to these abnormalities is unclear. METHODS We randomly assigned 181 patients with obesity, moderate-to-severe obstructive sleep apnea, and serum levels of C-reactive protein (CRP) greater than 1.0 mg per liter to receive treatment with continuous positive airway pressure (CPAP), a weight-loss intervention, or CPAP plus a weight-loss intervention for 24 weeks. We assessed the incremental effect of the combined interventions over each one alone on the CRP level (the primary end point), insulin sensitivity, lipid levels, and blood pressure. RESULTS Among the 146 participants for whom there were follow-up data, those assigned to weight loss only and those assigned to the combined interventions had reductions in CRP levels, insulin resistance, and serum triglyceride levels. None of these changes were observed in the group receiving CPAP alone. Blood pressure was reduced in all three groups. No significant incremental effect on CRP levels was found for the combined interventions as compared with either weight loss or CPAP alone. Reductions in insulin resistance and serum triglyceride levels were greater in the combined-intervention group than in the group receiving CPAP only, but there were no significant differences in these values between the combined-intervention group and the weight-loss group. In per-protocol analyses, which included 90 participants who met prespecified criteria for adherence, the combined interventions resulted in a larger reduction in systolic blood pressure and mean arterial pressure than did either CPAP or weight loss alone. CONCLUSIONS In adults with obesity and obstructive sleep apnea, CPAP combined with a weight-loss intervention did not reduce CRP levels more than either intervention alone. In secondary analyses, weight loss provided an incremental reduction

  14. Effects of continuous positive airway pressure treatment on clinic and ambulatory blood pressures in patients with obstructive sleep apnea and resistant hypertension: a randomized controlled trial.

    PubMed

    Muxfeldt, Elizabeth S; Margallo, Victor; Costa, Leonardo M S; Guimarães, Gleison; Cavalcante, Aline H; Azevedo, João C M; de Souza, Fabio; Cardoso, Claudia R L; Salles, Gil F

    2015-04-01

    The effect of continuous positive airway pressure (CPAP) on blood pressures (BPs) in patients with resistant hypertension and obstructive sleep apnea is not established. We aimed to evaluate it in a randomized controlled clinical trial, with blinded assessment of outcomes. Four hundred thirty-four resistant hypertensive patients were screened and 117 patients with moderate/severe obstructive sleep apnea, defined by an apnea-hypopnea index ≥15 per hour, were randomized to 6-month CPAP treatment (57 patients) or no therapy (60 patients), while maintaining antihypertensive treatment. Clinic and 24-hour ambulatory BPs were obtained before and after 6-month treatment. Primary outcomes were changes in clinic and ambulatory BPs and in nocturnal BP fall patterns. Intention-to-treat and per-protocol (limited to those with uncontrolled ambulatory BPs) analyses were performed. Patients had mean (SD) 24-hour BP of 129(16)/75(12) mm Hg, and 59% had uncontrolled ambulatory BPs. Mean apnea-hypopnea index was 41 per hour and 58.5% had severe obstructive sleep apnea. On intention-to-treat analysis, there was no significant difference in any BP change, neither in nocturnal BP fall, between CPAP and control groups. The best effect of CPAP was on night-time systolic blood pressure in per-protocol analysis, with greater reduction of 4.7 mm Hg (95% confidence interval, -11.3 to +3.1 mm Hg; P=0.24) and an increase in nocturnal BP fall of 2.2% (95% confidence interval, -1.6% to +5.8%; P=0.25), in comparison with control group. In conclusion, CPAP treatment had no significant effect on clinic and ambulatory BPs in patients with resistant hypertension and moderate/severe obstructive sleep apnea, although a beneficial effect on night-time systolic blood pressure and on nocturnal BP fall might exist in patients with uncontrolled ambulatory BP levels.

  15. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  16. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  17. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  18. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  19. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Inspiratory airway pressure meter. 868.1780... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1780 Inspiratory airway pressure meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the...

  20. Baroreflex control of heart rate during sleep in severe obstructive sleep apnoea: effects of acute CPAP.

    PubMed

    Bonsignore, M R; Parati, G; Insalaco, G; Castiglioni, P; Marrone, O; Romano, S; Salvaggio, A; Mancia, G; Bonsignore, G; Di Rienzo, M

    2006-01-01

    Baroreflex control of heart rate during sleep (baroreflex sensitivity; BRS) has been shown to be depressed in obstructive sleep apnoea (OSA), and improved after treatment with continuous positive airway pressure (CPAP). Whether CPAP also acutely affects BRS during sleep in uncomplicated severe OSA is still debatable. Blood pressure was monitored during nocturnal polysomnography in 18 patients at baseline and during first-time CPAP application. Spontaneous BRS was analysed by the sequence method, and estimated as the mean sequence slope. CPAP did not acutely affect mean blood pressure or heart rate but decreased cardiovascular variability during sleep. Mean BRS increased slightly during CPAP application (from 6.5+/-2.4 to 7.5+/-2.9 ms x mmHg(-1)), mostly in response to decreasing blood pressure. The change in BRS did not correlate with changes in arterial oxygen saturation or apnoea/hypopnoea index. The small change in baroreflex control of heart rate during sleep at first application of continuous positive airway pressure in severe obstructive sleep apnoea was unrelated to the acute resolution of nocturnal hypoxaemia, and might reflect autonomic adjustments to positive intrathoracic pressure, and/or improved sleep architecture. The small increase in baroreflex control of heart rate during sleep may be of clinical relevance as it was accompanied by reduced cardiovascular variability, which is acknowledged as an independent cardiovascular risk factor.

  1. Evaluation of effect of continuous positive airway pressure during cardiopulmonary bypass on cardiac de-airing after open heart surgery in randomized clinical trial

    PubMed Central

    Mansour, Mojtaba; Massodnia, Nasim; Mirdehghan, Abolghasem; Bigdelian, Hamid; Massoumi, Gholamreza; Alavi, Zeinab Rafieipour

    2014-01-01

    Background: Cardiac and pulmonary veins de-airing are of the most important steps during open heart surgery. This study evaluates the effect of continuous positive airway pressure (CPAP) on air trapping in pulmonary veins and on quality of de-airing procedure. Materials and Methods: This randomized prospective double blind clinical trial conducted on 40 patients. In the control group: During cardiopulmonary bypass (CPB), the ventilator was turned off and adjustable pressure limit (APL) valve was placed in SPONT position. In CPAP group: During CPB, after turning the ventilator off, the flow of oxygen flow was maintained at the rate of 0.5 L/min and the APL valve was placed in MAN position on 20 mbar. During cardiopulmonary bypass (CPB) weaning, the patients were observed for air bubbles in left atrium by using transesophageal echocardiography. Results: The mean de-airing time after the start of mechanical ventilation in CPAP group (n = 20) was significantly lower than the control group (n = 20) (P = 0.0001). The mean time of the left atrium air bubbles occupation as mild (P = 0.004), moderate (P = 0.0001) and severe (P = 0.015) grading was significantly lower in CPAP group. Conclusions: By CPAP at 20 mbar during CPB in open heart surgery, de-airing process can be down in better quality and in significantly shorter time. PMID:24949307

  2. The impact of modified tongue base suspension on CPAP levels in patients with severe OSA.

    PubMed

    Turhan, Murat; Bostanci, Asli; Akdag, Mehmet

    2015-04-01

    The aim of this study was to evaluate the effects of modified tongue base suspension (mTBS) procedure on continuous positive airway pressure (CPAP) levels in patients with severe obstructive sleep apnea (OSA). From November 2011 to December 2012, a total of 31 patients with severe OSA who underwent mTBS were included into this prospective case series with planned data collection. Prior to surgery, all the patients were subjected to a polysomnography (PSG) and CPAP titration on two separate nights. Following the surgery, patients were subjected to a control PSG and CPAP titration at the sixth month of follow-up period. The preoperative and postoperative mean apnea hypopnea index (AHI), CPAP titration values, AHI during CPAP use and amount of sleeping time with CPAP were compared. Median age was 48 years (range 31-66), and most patients were male (87.0 %). Postoperative mean AHI (44.73 ± 17.05 vs. 19.96 ± 19.52), optimal CPAP value (12.64 ± 1.60 vs. 8.00 ± 1.77) and AHI during CPAP use (3.79 ± 1.78 vs. 2.25 ± 1.81) were decreased, and the amount of sleeping time with CPAP (5.29 ± 0.84 vs. 6.52 ± 0.89) was increased significantly (p < 0.001 for all parameters). The surgery was considered to be successful when 50 % reduction in the mean AHI and/or the decrease of AHI below 20/h were obtained. A total of 24 patients (77.4 %) met the surgical success criteria. The mTBS is a safe and feasible procedure with favorable effects on CPAP levels in patients with severe OSA.

  3. CPAP and High-Flow Nasal Cannula Oxygen in Bronchiolitis.

    PubMed

    Sinha, Ian P; McBride, Antonia K S; Smith, Rachel; Fernandes, Ricardo M

    2015-09-01

    Severe respiratory failure develops in some infants with bronchiolitis because of a complex pathophysiologic process involving increased airways resistance, alveolar atelectasis, muscle fatigue, and hypoxemia due to mismatch between ventilation and perfusion. Nasal CPAP and high-flow nasal cannula (HFNC) oxygen may improve the work of breathing and oxygenation. Although the mechanisms behind these noninvasive modalities of respiratory support are not well understood, they may help infants by way of distending pressure and delivery of high concentrations of warmed and humidified oxygen. Observational studies of varying quality have suggested that CPAP and HFNC may confer direct physiologic benefits to infants with bronchiolitis and that their use has reduced the need for intubation. No trials to our knowledge, however, have compared CPAP with HFNC in bronchiolitis. Two randomized trials compared CPAP with oxygen delivered by low-flow nasal cannula or face mask and found some improvements in blood gas results and some physiologic parameters, but these trials were unable to demonstrate a reduction in the need for intubation. Two trials evaluated HFNC in bronchiolitis (one comparing it with headbox oxygen, the other with nebulized hypertonic saline), with the results not seeming to suggest important clinical or physiologic benefits. In this article, we review the pathophysiology of respiratory failure in bronchiolitis, discuss these trials in detail, and consider how future research studies may be designed to best evaluate CPAP and HFNC in bronchiolitis.

  4. CPAP and High-Flow Nasal Cannula Oxygen in Bronchiolitis.

    PubMed

    Sinha, Ian P; McBride, Antonia K S; Smith, Rachel; Fernandes, Ricardo M

    2015-09-01

    Severe respiratory failure develops in some infants with bronchiolitis because of a complex pathophysiologic process involving increased airways resistance, alveolar atelectasis, muscle fatigue, and hypoxemia due to mismatch between ventilation and perfusion. Nasal CPAP and high-flow nasal cannula (HFNC) oxygen may improve the work of breathing and oxygenation. Although the mechanisms behind these noninvasive modalities of respiratory support are not well understood, they may help infants by way of distending pressure and delivery of high concentrations of warmed and humidified oxygen. Observational studies of varying quality have suggested that CPAP and HFNC may confer direct physiologic benefits to infants with bronchiolitis and that their use has reduced the need for intubation. No trials to our knowledge, however, have compared CPAP with HFNC in bronchiolitis. Two randomized trials compared CPAP with oxygen delivered by low-flow nasal cannula or face mask and found some improvements in blood gas results and some physiologic parameters, but these trials were unable to demonstrate a reduction in the need for intubation. Two trials evaluated HFNC in bronchiolitis (one comparing it with headbox oxygen, the other with nebulized hypertonic saline), with the results not seeming to suggest important clinical or physiologic benefits. In this article, we review the pathophysiology of respiratory failure in bronchiolitis, discuss these trials in detail, and consider how future research studies may be designed to best evaluate CPAP and HFNC in bronchiolitis. PMID:25836649

  5. Effects of continuous positive airway pressure on blood pressure in patients with resistant hypertension and obstructive sleep apnea: a meta-analysis

    PubMed Central

    Iftikhar, Imran H.; Valentine, Christopher W.; Bittencourt, Lia R.A.; Cohen, Debbie L.; Fedson, Annette C.; Gíslason, Thorarinn; Penzel, Thomas; Phillips, Craig L.; Yu-sheng, Lin; Pack, Allan I.; Magalang, Ulysses J.

    2015-01-01

    Objective To systematically analyze the studies that have examined the effect of continuous positive airway pressure (CPAP) on blood pressure (BP) in patients with resistant hypertension and obstructive sleep apnea (OSA). Methods Design – meta-analysis of observational studies and randomized controlled trials (RCTs) indexed in PubMed and Ovid (All Journals@Ovid). participants: individuals with resistant hypertension and OSA; interventions – CPAP treatment. Results A total of six studies met the inclusion criteria for preintervention to postintervention analyses. The pooled estimates of mean changes after CPAP treatment for the ambulatory (24-h) SBP and DBP from six studies were −7.21 mmHg [95% confidence interval (CI): −9.04 to −5.38; P <0.001; I2 58%) and −4.99 mmHg (95% CI: −6.01 to −3.96; P <0.001; I2 31%), respectively. The pooled estimate of the ambulatory SBP and DBP from the four RCTs showed a mean net change of −6.74 mmHg [95% CI: −9.98 to −3.49; P <0.001; I2 61%] and −5.94 mmHg (95% CI: −9.40 to −2.47; P =0.001; I2 76%), respectively, in favor of the CPAP group. Conclusion The pooled estimate shows a favorable reduction of BP with CPAP treatment in patients with resistant hypertension and OSA. The effects sizes are larger than those previously reported in patients with OSA without resistant hypertension. PMID:25243523

  6. CPAP for Prevention of Cardiovascular Events in Obstructive Sleep Apnea.

    PubMed

    McEvoy, R Doug; Antic, Nick A; Heeley, Emma; Luo, Yuanming; Ou, Qiong; Zhang, Xilong; Mediano, Olga; Chen, Rui; Drager, Luciano F; Liu, Zhihong; Chen, Guofang; Du, Baoliang; McArdle, Nigel; Mukherjee, Sutapa; Tripathi, Manjari; Billot, Laurent; Li, Qiang; Lorenzi-Filho, Geraldo; Barbe, Ferran; Redline, Susan; Wang, Jiguang; Arima, Hisatomi; Neal, Bruce; White, David P; Grunstein, Ron R; Zhong, Nanshan; Anderson, Craig S

    2016-09-01

    Background Obstructive sleep apnea is associated with an increased risk of cardiovascular events; whether treatment with continuous positive airway pressure (CPAP) prevents major cardiovascular events is uncertain. Methods After a 1-week run-in period during which the participants used sham CPAP, we randomly assigned 2717 eligible adults between 45 and 75 years of age who had moderate-to-severe obstructive sleep apnea and coronary or cerebrovascular disease to receive CPAP treatment plus usual care (CPAP group) or usual care alone (usual-care group). The primary composite end point was death from cardiovascular causes, myocardial infarction, stroke, or hospitalization for unstable angina, heart failure, or transient ischemic attack. Secondary end points included other cardiovascular outcomes, health-related quality of life, snoring symptoms, daytime sleepiness, and mood. Results Most of the participants were men who had moderate-to-severe obstructive sleep apnea and minimal sleepiness. In the CPAP group, the mean duration of adherence to CPAP therapy was 3.3 hours per night, and the mean apnea-hypopnea index (the number of apnea or hypopnea events per hour of recording) decreased from 29.0 events per hour at baseline to 3.7 events per hour during follow-up. After a mean follow-up of 3.7 years, a primary end-point event had occurred in 229 participants in the CPAP group (17.0%) and in 207 participants in the usual-care group (15.4%) (hazard ratio with CPAP, 1.10; 95% confidence interval, 0.91 to 1.32; P=0.34). No significant effect on any individual or other composite cardiovascular end point was observed. CPAP significantly reduced snoring and daytime sleepiness and improved health-related quality of life and mood. Conclusions Therapy with CPAP plus usual care, as compared with usual care alone, did not prevent cardiovascular events in patients with moderate-to-severe obstructive sleep apnea and established cardiovascular disease. (Funded by the National Health and

  7. CPAP for Prevention of Cardiovascular Events in Obstructive Sleep Apnea.

    PubMed

    McEvoy, R Doug; Antic, Nick A; Heeley, Emma; Luo, Yuanming; Ou, Qiong; Zhang, Xilong; Mediano, Olga; Chen, Rui; Drager, Luciano F; Liu, Zhihong; Chen, Guofang; Du, Baoliang; McArdle, Nigel; Mukherjee, Sutapa; Tripathi, Manjari; Billot, Laurent; Li, Qiang; Lorenzi-Filho, Geraldo; Barbe, Ferran; Redline, Susan; Wang, Jiguang; Arima, Hisatomi; Neal, Bruce; White, David P; Grunstein, Ron R; Zhong, Nanshan; Anderson, Craig S

    2016-09-01

    Background Obstructive sleep apnea is associated with an increased risk of cardiovascular events; whether treatment with continuous positive airway pressure (CPAP) prevents major cardiovascular events is uncertain. Methods After a 1-week run-in period during which the participants used sham CPAP, we randomly assigned 2717 eligible adults between 45 and 75 years of age who had moderate-to-severe obstructive sleep apnea and coronary or cerebrovascular disease to receive CPAP treatment plus usual care (CPAP group) or usual care alone (usual-care group). The primary composite end point was death from cardiovascular causes, myocardial infarction, stroke, or hospitalization for unstable angina, heart failure, or transient ischemic attack. Secondary end points included other cardiovascular outcomes, health-related quality of life, snoring symptoms, daytime sleepiness, and mood. Results Most of the participants were men who had moderate-to-severe obstructive sleep apnea and minimal sleepiness. In the CPAP group, the mean duration of adherence to CPAP therapy was 3.3 hours per night, and the mean apnea-hypopnea index (the number of apnea or hypopnea events per hour of recording) decreased from 29.0 events per hour at baseline to 3.7 events per hour during follow-up. After a mean follow-up of 3.7 years, a primary end-point event had occurred in 229 participants in the CPAP group (17.0%) and in 207 participants in the usual-care group (15.4%) (hazard ratio with CPAP, 1.10; 95% confidence interval, 0.91 to 1.32; P=0.34). No significant effect on any individual or other composite cardiovascular end point was observed. CPAP significantly reduced snoring and daytime sleepiness and improved health-related quality of life and mood. Conclusions Therapy with CPAP plus usual care, as compared with usual care alone, did not prevent cardiovascular events in patients with moderate-to-severe obstructive sleep apnea and established cardiovascular disease. (Funded by the National Health and

  8. Continuous positive airway pressure treatment for obstructive sleep apnoea reduces resting heart rate but does not affect dysrhythmias: a randomised controlled trial.

    PubMed

    Craig, Sonya; Pepperell, Justin C T; Kohler, Malcolm; Crosthwaite, Nicky; Davies, Robert J O; Stradling, John R

    2009-09-01

    Obstructive sleep apnoea (OSA) is associated with cardiovascular morbidity and may precipitate cardiac dysrhythmias. Uncontrolled reports suggest that continuous positive airway pressure (CPAP) may reduce dysrhythmia frequency and resting heart rate. We undertook a randomised controlled trial of therapeutic CPAP and compared with a subtherapeutic control which included an exploration of changes in dysrhythmia frequency and heart rate. Values are expressed as mean (SD). Eighty-three men [49.5 (9.6) years] with moderate-severe OSA [Oxygen Desaturation Index, 41.2 (24.3) dips per hour] underwent 3-channel 24-h electrocardiograms during normal daily activities, before and after 1 month of therapeutic (n = 43) or subtherapeutic (n = 40) CPAP. Recordings were manually analysed for mean heart rate, pauses, bradycardias, supraventricular and ventricular dysrhythmias. The two groups were well matched for age, body mass index, OSA severity, cardiovascular risk factors and history. Supraventricular ectopics and ventricular ectopics were frequently found in 95.2% and 85.5% of patients, respectively. Less common were sinus pauses (42.2%), episodes of bradycardia (12%) and ventricular tachycardias (4.8%). Compared with subtherapeutic control, CPAP reduced mean 24-h heart rate from 83.0 (11.5) to 79.7 (9.8) (P < 0.002) in the CPAP group compared with a non-significant rise (P = 0.18) from 79.0 (10.4) to 79.9 (10.4) in the subtherapeutic group; this was also the case for the day period analysed separately. There was no significant change in the frequencies of dysrhythmias after CPAP. Four weeks of CPAP therapy reduces mean 24-h heart rate possibly due to reduced sympathetic activation but did not result in a significant decrease in dysrhythmia frequency.

  9. Treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Patient compliance, perception of benefits, and side effects.

    PubMed

    Hoffstein, V; Viner, S; Mateika, S; Conway, J

    1992-04-01

    Obstructive sleep apnea is a chronic disease whose treatment may require long-term nightly use of relatively cumbersome and expensive breathing equipment that provides continuous positive airway pressure (CPAP) via nasal mask. Compliance with this treatment may be influenced not only by the objective improvement in sleep apnea but also by the patient's subjective perception of the benefit, bed mate or family support, side effects, and cost. The last factor may not be important in Ontario, where 75% of the cost is paid by the Ministry of Health. The goal of this study was to analyze the factors that may influence patient acceptance of nasal CPAP. This was done by tabulating the responses to a detailed questionnaire mailed to 148 patients with obstructive sleep apnea (OSA). There were 96 replies. We were able to contact by telephone an additional 42 patients. The results showed that 105 patients continued to use CPAP at a mean follow-up time of 17 +/- 11 months, some for as long as 6 yr. The majority of patients (81%) perceived CPAP as an effective treatment of the disorder, 5% were unsure, and 14% believed that CPAP was ineffective, despite the resolution of sleep apnea on polysomnography. Subjective improvement reported by the patients was also observed by the family members in 83% of the patients. The most common complaint, voiced by 46% of the patients, was nocturnal awakenings. Nasal problems, such as dryness, congestion, and sneezing, were the second most frequent complaint present in 44% of the responders.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1554212

  10. Impact of a New Nasal Pillows Mask on Patients' Acceptance, Compliance, and Willingness to Remain on CPAP Therapy.

    PubMed

    Wimms, Alison; Ketheeswaran, Sahisha; Ziegenbein, Claus; Jennings, Laura; Woehrle, Holger

    2016-01-01

    Aim. Continuous positive airway pressure (CPAP) masks are a key factor in patient compliance. This program assessed the performance of a new nasal pillows mask (NPM) on a variety of new and established obstructive sleep apnea (OSA) patients using CPAP therapy. Methods. Five programs were developed to assess the new NPM [AirFit P10, ResMed] on naïve patients; patients established on another NPM; patients using a nasal mask; patients with low CPAP compliance; and patients who wished to stop using CPAP therapy. Results. A total of 212 patients were included. In naïve patients, CPAP usage after 3 months was 5.9 ± 1.7 hours/night, compared with the control group at 4.6 ± 2.4 hours/night (p < 0.05). In patients established on another NPM, usage improved to 7.4 ± 1.1 hours/night versus 6.7 ± 1.4 (p = 0.001). 78% of nasal mask users wished to continue using the new NPM. Low compliance patients improved with an average of 0.87 hours/night (p = 0.001) when using the new NPM. In patients at the point of quitting CPAP, 60% continued with therapy using the new NPM. Conclusion. The new NPM mask performed well in a variety of clinical groups of OSA patients receiving CPAP therapy and shows that technical advances in CPAP masks can improve patient compliance.

  11. Impact of a New Nasal Pillows Mask on Patients' Acceptance, Compliance, and Willingness to Remain on CPAP Therapy

    PubMed Central

    Ketheeswaran, Sahisha; Jennings, Laura; Woehrle, Holger

    2016-01-01

    Aim. Continuous positive airway pressure (CPAP) masks are a key factor in patient compliance. This program assessed the performance of a new nasal pillows mask (NPM) on a variety of new and established obstructive sleep apnea (OSA) patients using CPAP therapy. Methods. Five programs were developed to assess the new NPM [AirFit P10, ResMed] on naïve patients; patients established on another NPM; patients using a nasal mask; patients with low CPAP compliance; and patients who wished to stop using CPAP therapy. Results. A total of 212 patients were included. In naïve patients, CPAP usage after 3 months was 5.9 ± 1.7 hours/night, compared with the control group at 4.6 ± 2.4 hours/night (p < 0.05). In patients established on another NPM, usage improved to 7.4 ± 1.1 hours/night versus 6.7 ± 1.4 (p = 0.001). 78% of nasal mask users wished to continue using the new NPM. Low compliance patients improved with an average of 0.87 hours/night (p = 0.001) when using the new NPM. In patients at the point of quitting CPAP, 60% continued with therapy using the new NPM. Conclusion. The new NPM mask performed well in a variety of clinical groups of OSA patients receiving CPAP therapy and shows that technical advances in CPAP masks can improve patient compliance. PMID:27648308

  12. Impact of a New Nasal Pillows Mask on Patients' Acceptance, Compliance, and Willingness to Remain on CPAP Therapy.

    PubMed

    Wimms, Alison; Ketheeswaran, Sahisha; Ziegenbein, Claus; Jennings, Laura; Woehrle, Holger

    2016-01-01

    Aim. Continuous positive airway pressure (CPAP) masks are a key factor in patient compliance. This program assessed the performance of a new nasal pillows mask (NPM) on a variety of new and established obstructive sleep apnea (OSA) patients using CPAP therapy. Methods. Five programs were developed to assess the new NPM [AirFit P10, ResMed] on naïve patients; patients established on another NPM; patients using a nasal mask; patients with low CPAP compliance; and patients who wished to stop using CPAP therapy. Results. A total of 212 patients were included. In naïve patients, CPAP usage after 3 months was 5.9 ± 1.7 hours/night, compared with the control group at 4.6 ± 2.4 hours/night (p < 0.05). In patients established on another NPM, usage improved to 7.4 ± 1.1 hours/night versus 6.7 ± 1.4 (p = 0.001). 78% of nasal mask users wished to continue using the new NPM. Low compliance patients improved with an average of 0.87 hours/night (p = 0.001) when using the new NPM. In patients at the point of quitting CPAP, 60% continued with therapy using the new NPM. Conclusion. The new NPM mask performed well in a variety of clinical groups of OSA patients receiving CPAP therapy and shows that technical advances in CPAP masks can improve patient compliance. PMID:27648308

  13. Impact of a New Nasal Pillows Mask on Patients' Acceptance, Compliance, and Willingness to Remain on CPAP Therapy

    PubMed Central

    Ketheeswaran, Sahisha; Jennings, Laura; Woehrle, Holger

    2016-01-01

    Aim. Continuous positive airway pressure (CPAP) masks are a key factor in patient compliance. This program assessed the performance of a new nasal pillows mask (NPM) on a variety of new and established obstructive sleep apnea (OSA) patients using CPAP therapy. Methods. Five programs were developed to assess the new NPM [AirFit P10, ResMed] on naïve patients; patients established on another NPM; patients using a nasal mask; patients with low CPAP compliance; and patients who wished to stop using CPAP therapy. Results. A total of 212 patients were included. In naïve patients, CPAP usage after 3 months was 5.9 ± 1.7 hours/night, compared with the control group at 4.6 ± 2.4 hours/night (p < 0.05). In patients established on another NPM, usage improved to 7.4 ± 1.1 hours/night versus 6.7 ± 1.4 (p = 0.001). 78% of nasal mask users wished to continue using the new NPM. Low compliance patients improved with an average of 0.87 hours/night (p = 0.001) when using the new NPM. In patients at the point of quitting CPAP, 60% continued with therapy using the new NPM. Conclusion. The new NPM mask performed well in a variety of clinical groups of OSA patients receiving CPAP therapy and shows that technical advances in CPAP masks can improve patient compliance.

  14. Effects of caffeine and/or nasal CPAP treatment on laryngeal chemoreflexes in preterm lambs.

    PubMed

    Boudaa, Nadia; Samson, Nathalie; Carrière, Vincent; Germim, Pamela Samanta; Pasquier, Jean-Charles; Bairam, Aida; Praud, Jean-Paul

    2013-03-01

    Current knowledge suggests that laryngeal chemoreflexes (LCR) are involved in the occurrence of certain neonatal apneas/bradycardias, especially in the preterm newborn. While caffeine and/or nasal continuous positive airway pressure (nCPAP) are the most frequent options used for treating apneas in preterm newborns, their effects on LCR-related apneas/bradycardias are virtually unknown. The aim of the present study was to test the hypothesis that caffeine and/or nCPAP decreases LCR-related cardiorespiratory inhibition in a preterm ovine model. Seven preterm lambs were born vaginally on gestational day 133 (normal gestation: 147 days) after intramuscular injections of betamethasone and mifepristone. Five days after birth, a chronic surgical instrumentation was performed to record states of alertness, electrocardiogram, systemic arterial pressure, and electromyographic activity of a laryngeal constrictor muscle, as well as to insert a transcutaneous supraglottal catheter. LCR were induced in quiet sleep under four conditions: 1) control (without caffeine or nCPAP); 2) nCPAP (5 cmH2O, without caffeine); 3) caffeine (10 mg/kg infused intravenously for 30 min, without nCPAP); and 4) nCPAP + caffeine. Our results showed that nCPAP consistently blunted LCR-related cardiorespiratory inhibition vs. control condition, contrary to caffeine whose overall effect was nonsignificant. In addition, nCPAP condition was characterized by a more consistent and rapid arousal after HCl injection. No significant differences were observed between all tested conditions with regard to swallowing and cough. It is concluded that nCPAP should be further assessed for its usefulness in treating neonatal apneas linked to LCR.

  15. Randomized Controlled Trial Comparing Flexible and Continuous Positive Airway Pressure Delivery: Effects on Compliance, Objective and Subjective Sleepiness and Vigilance

    PubMed Central

    Bakker, Jessie; Campbell, Angela; Neill, Alister

    2010-01-01

    Study Objectives: Positive airway pressure (PAP) treatment for obstructive sleep apnea (OSA) can be limited by suboptimal compliance. C-Flex technology (Philips Respironics, PA, USA) reduces pressure during expiration, aiming to improve comfort and therefore compliance. This may be of particular relevance to patients requiring high pressures. Many studies thus far have suffered from design limitations and small sample sizes. This study aimed to compare compliance with C-Flex and CPAP, as well as analyzing objective and subjective sleepiness and vigilance. Design: Three-month, double-blinded, parallel-arm randomized controlled trial. Setting: A university-based sleep laboratory. Patients: 76 consecutive patients with severe OSA (mean ± SD AHI 60.2 ± 32.9 events/hour, ESS 13.6 ± 4.5/24, BMI 35.6 ± 7.8 kg/m2), without significant cardiac, respiratory, psychiatric, or sleep comorbidities. Interventions: Patients were randomized to C-Flex (dip level 2) or CPAP. Measurements and Results: Patients underwent titration with C-Flex/CPAP (mean pressure 11.6 cm H2O). Modified maintenance of wakefulness tests (mod-MWT), psychomotor vigilance tasks (PVT) and questionnaires were administered at baseline and after one and 3 months. Median compliance was 5.51 and 5.89 h/ night in the C-Flex and CPAP groups respectively (P = 0.82). There were no significant differences between groups in terms of PVT reaction time, subjective sleepiness, sleep quality, health-related quality of life, or treatment comfort. There was no significant difference between the groups regarding the change in mod-MWT sleep latency values. Conclusions: In patients with severe OSA both CPAP and C-Flex resulted in substantial improvements in sleepiness, vigilance, and quality of life. The use of C-Flex did not result in greater compliance, and neither treatment appeared superior. Citation: Bakker J; Campbell A; Neill A. Randomized controlled trial comparing flexible and continuous positive airway pressure

  16. Practice Parameters for the Use of Autotitrating Continuous Positive Airway Pressure Devices for Titrating Pressures and Treating Adult Patients with Obstructive Sleep Apnea Syndrome: An Update for 2007

    PubMed Central

    Morgenthaler, Timothy I.; Aurora, R. Nisha; Brown, Terry; Zak, Rochelle; Alessi, Cathy; Boehlecke, Brian; Chesson, Andrew L.; Friedman, Leah; Kapur, Vishesh; Maganti, Rama; Owens, Judith; Pancer, Jeffrey; Swick, Todd J.

    2008-01-01

    These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without

  17. An evaluation of the relative efficacy of an open airway, an oxygen reservoir and continuous positive airway pressure 5 cmH2O on the non-ventilated lung.

    PubMed

    Slimani, J; Russell, W J; Jurisevic, C

    2004-12-01

    The aim of this study, during one-lung ventilation, was to evaluate if oxygenation could be improved by use of a simple oxygen reservoir or application of 5 cmH2O continuous positive airway pressure (CPAP) to the non-ventilated lung compared with an open airway. Twenty-three patients with lung malignancy, undergoing thoracotomy requiring at least 60 minutes of one-lung ventilation before lung lobe excision, were studied. After routine induction and establishment of one-lung ventilation, the three treatments were applied in turn to the same patient in a sequence selected randomly. The first treatment was repeated as a fourth treatment and these results of the repeated treatment averaged to minimize the effect of slow changes. Arterial oxygenation was measured by an arterial blood gas 15 minutes after the application of each treatment. Twenty patients completed the study. Mean PaO2 (in mmHg) was 210.3 (SD 105.5) in the "OPEN" treatment, 186.0 (SD 109.2) in the "RESERVOIR" treatment, and 240.5 (SD 116.0) in the "CPAP" treatment. This overall difference was not quite significant (P = 0.058, paired ANOVA), but comparison of the pairs showed that there was a significant better oxygenation only with the CPAP compared to the reservoir treatments (t = 2.52, P = 0.021). While the effect on the surgical field was not apparent in most patients, in one patient surgery was impeded during CPAP. Our results show that the use of a reservoir does not give oxygenation better than an open tube, and is less effective than the use of CPAP 5 cmH2O on the non-ventilated lung during one-lung ventilation.

  18. Efficacy and safety of CPAP in low- and middle-income countries.

    PubMed

    Thukral, A; Sankar, M J; Chandrasekaran, A; Agarwal, R; Paul, V K

    2016-05-01

    We conducted a systematic review to evaluate the (1) feasibility and efficacy and (2) safety and cost effectiveness of continuous positive airway pressure (CPAP) therapy in low- and middle-income countries (LMIC). We searched the following electronic bibliographic databases-MEDLINE, Cochrane CENTRAL, CINAHL, EMBASE and WHOLIS-up to December 2014 and included all studies that enrolled neonates requiring CPAP therapy for any indication. We did not find any randomized trials from LMICs that have evaluated the efficacy of CPAP therapy. Pooled analysis of four observational studies showed 66% reduction in in-hospital mortality following CPAP in preterm neonates (odds ratio 0.34, 95% confidence interval (CI) 0.14 to 0.82). One study reported 50% reduction in the need for mechanical ventilation following the introduction of bubble CPAP (relative risk 0.5, 95% CI 0.37 to 0.66). The proportion of neonates who failed CPAP and required mechanical ventilation varied from 20 to 40% (eight studies). The incidence of air leaks varied from 0 to 7.2% (nine studies). One study reported a significant reduction in the cost of surfactant usage with the introduction of CPAP. Available evidence suggests that CPAP is a safe and effective mode of therapy in preterm neonates with respiratory distress in LMICs. It reduces the in-hospital mortality and the need for ventilation thereby minimizing the need for up-transfer to a referral hospital. But given the overall paucity of studies and the low quality evidence underscores the need for large high-quality studies on the safety, efficacy and cost effectiveness of CPAP therapy in these settings.

  19. Efficacy and safety of CPAP in low- and middle-income countries

    PubMed Central

    Thukral, A; Sankar, M J; Chandrasekaran, A; Agarwal, R; Paul, V K

    2016-01-01

    We conducted a systematic review to evaluate the (1) feasibility and efficacy and (2) safety and cost effectiveness of continuous positive airway pressure (CPAP) therapy in low- and middle-income countries (LMIC). We searched the following electronic bibliographic databases—MEDLINE, Cochrane CENTRAL, CINAHL, EMBASE and WHOLIS—up to December 2014 and included all studies that enrolled neonates requiring CPAP therapy for any indication. We did not find any randomized trials from LMICs that have evaluated the efficacy of CPAP therapy. Pooled analysis of four observational studies showed 66% reduction in in-hospital mortality following CPAP in preterm neonates (odds ratio 0.34, 95% confidence interval (CI) 0.14 to 0.82). One study reported 50% reduction in the need for mechanical ventilation following the introduction of bubble CPAP (relative risk 0.5, 95% CI 0.37 to 0.66). The proportion of neonates who failed CPAP and required mechanical ventilation varied from 20 to 40% (eight studies). The incidence of air leaks varied from 0 to 7.2% (nine studies). One study reported a significant reduction in the cost of surfactant usage with the introduction of CPAP. Available evidence suggests that CPAP is a safe and effective mode of therapy in preterm neonates with respiratory distress in LMICs. It reduces the in-hospital mortality and the need for ventilation thereby minimizing the need for up-transfer to a referral hospital. But given the overall paucity of studies and the low quality evidence underscores the need for large high-quality studies on the safety, efficacy and cost effectiveness of CPAP therapy in these settings. PMID:27109089

  20. Positive airway pressure therapy for heart failure.

    PubMed

    Kato, Takao; Suda, Shoko; Kasai, Takatoshi

    2014-11-26

    Heart failure (HF) is a life-threatening disease and is a growing public health concern. Despite recent advances in pharmacological management for HF, the morbidity and mortality from HF remain high. Therefore, non-pharmacological approaches for HF are being developed. However, most non-pharmacological approaches are invasive, have limited indication and are considered only for advanced HF. Accordingly, the development of less invasive, non-pharmacological approaches that improve outcomes for patients with HF is important. One such approach may include positive airway pressure (PAP) therapy. In this review, the role of PAP therapy applied through mask interfaces in the wide spectrum of HF care is discussed. PMID:25429330

  1. Residual effect of nCPAP applied for part of the night in patients with obstructive sleep apnoea.

    PubMed

    Hers, V; Liistro, G; Dury, M; Collard, P; Aubert, G; Rodenstein, D O

    1997-05-01

    The aim of the present study was to assess whether nasal continuous positive airway pressure (nCPAP) treatment, applied for only a few hours at the beginning of the night, has any residual effect on sleep and breathing during the ensuing hours of unassisted sleep in patients with obstructive sleep apnoea syndrome (OSAS). In 27 patients with newly-diagnosed OSAS, effective nCPAP was applied during the first part of the night and then withdrawn. Polysomnographic parameters after nCPAP withdrawal were compared with those of the corresponding part of the diagnostic polysomnography performed a few days or weeks before and with those of the first part of night on nCPAP. After 255+/-63 (mean+/-SD) min of sleep with normalization of sleep and breathing parameters under nCPAP, there was partial improvement of OSAS severity during the remaining 124+/-56 min of nocturnal sleep without treatment; mean oxygen saturation, desaturation index (equivalent to the apnoea/hypopnoea index) and movement arousal index all improved significantly with respect to the diagnostic night (p=0.001). This improvement was not accounted for by a change in sleep architecture. We conclude that there is an improvement in severity of obstructive sleep apnoea syndrome after only 4 h of nasal continuous positive airway pressure. This carryover effect could explain why a number of patients with obstructive sleep apnoea syndrome apply nasal continuous positive airway pressure for only part of the night or not every night.

  2. Heart rate variability in non-apneic snorers and controls before and after continuous positive airway pressure

    PubMed Central

    Gates, Gregory J; Mateika, Susan E; Mateika, Jason H

    2005-01-01

    Background We hypothesized that sympathetic nervous system activity (SNSA) is increased and parasympathetic nervous system activity (PNSA) is decreased during non-rapid eye movement (NREM) sleep in non-apneic, otherwise healthy, snoring individuals compared to control. Moreover, we hypothesized that these alterations in snoring individuals would be more evident during non-snoring than snoring when compared to control. Methods To test these hypotheses, heart rate variability was used to measure PNSA and SNSA in 11 normotensive non-apneic snorers and 12 control subjects before and 7-days after adapting to nasal continuous positive airway pressure (nCPAP). Results Our results showed that SNSA was increased and PNSA was decreased in non-apneic snorers during NREM compared to control. However, these changes were only evident during the study in which snoring was eliminated with nCPAP. Conversely, during periods of snoring SNSA and PNSA were similar to measures obtained from the control group. Additionally, within the control group, SNSA and PNSA did not vary before and after nCPAP application. Conclusion Our findings suggest that long-lasting alterations in autonomic function may exist in snoring subjects that are otherwise healthy. Moreover, we speculate that because of competing inputs (i.e. inhibitory versus excitatory inputs) to the autonomic nervous system during snoring, the full impact of snoring on autonomic function is most evident during non-snoring periods. PMID:16048652

  3. A case series of skin necrosis following use of non invasive ventilation pressure masks.

    PubMed

    Ahmad, Z; Venus, M; Kisku, W; Rayatt, S S

    2013-02-01

    Two cases of nasal skin necrosis secondary to pressure from the use of continuous positive airway pressure (CPAP) face masks are presented. Both developed skin necrosis as a result of wearing these masks over the nasal bridge. These cases highlight the need for clinical vigilance in application of CPAP masks, the need for monitoring the skin of the nose during CPAP use and the possible need for modifications in design to help prevent this serious complication. PMID:22432901

  4. The impact of effective continuous positive airway pressure on homeostasis model assessment insulin resistance in non-diabetic patients with moderate to severe obstructive sleep apnea.

    PubMed

    Yang, Dan; Liu, Zhihong; Yang, Haixing

    2012-09-01

    Previous studies on the effects of continuous positive airway pressure (CPAP) on homeostasis model assessment insulin resistance (HOMA-IR) in obstructive sleep apnea patients have yielded conflicting results. Therefore, we conducted this meta-analysis to evaluate the impact of effective CPAP on HOMA-IR in non-diabetic patients with moderate to severe obstructive sleep apnea. We searched PubMed, HighWire Press, Ovid Medline (R), Cochrane library and EMBASE before December 2011 on original English language studies. The data on HOMA-IR and body mass index (BMI) were extracted from these studies. As compared with baseline values, 8 to 24 weeks of effective CPAP (>4 h/night) treatment significantly reduced HOMA-IR by an average of 0.75(95% CI, from -0.96 to -0.53; p < 0.001). However, in subjects with irregular CPAP (<4 h/night), this effect was not observed (-0.22; 95%CI, from -2.24 to 1.80; p = 0.83). There were no intervention-related changes in BMI in both regular and irregular CPAP. Our analysis showed that 8 to 24 weeks of effective CPAP could significantly improve HOMA-IR in non-diabetic patients with moderate to severe obstructive sleep apnea, while no significant changes in BMI were detected. Further large scale, randomized and controlled trials are needed to evaluate the longer treatment and its possible effects on weight control and cardiovascular disease.

  5. Sustainable use of continuous positive airway pressure in extremely preterm infants during the first week after delivery

    PubMed Central

    Booth, C; Premkumar, M H; Yannoulis, A; Thomson, M; Harrison, M; Edwards, A D

    2006-01-01

    Background Early use of nasal continuous positive airway pressure (nCPAP) may reduce lung damage, but it is not clear how many extremely preterm infants can be cared for without mechanical ventilation on the first days after delivery. Objectives To describe our experience of nCPAP in infants born at <27 weeks' gestation and to determine the chance of reintubation of this group of extremely preterm infants. Methods A retrospective, observational study examined the period from November 2002 to October 2003, when efforts were made to extubate infants to nCPAP at the earliest opportunity. Data were collected on all infants born at <27 weeks' and gestation admitted to The Neonatal Intensive Care Unit, Queen Charlotte's and Chelsea Hospital, London, UK. The chance of an individual infant requiring reintubation within 48 h of delivery was estimated, calculating the predictive probability using a Bayesian approach, and oxygen requirements at 36 weeks' postmenstrual age were examined. Results 60 infants, 34 inborn and 26 ex utero transfers, were admitted; 7 infants admitted 24 h after birth were excluded and 5 died within 48 h. The mean birth weight was 788 g and the gestational age was 25.3 weeks. Extubation was attempted on day 1 in 21 of 52 infants on ventilators and was successful in 14; and on day 2 in 14 of 35 and successful in 10 of infants extubated within 48 h of delivery survived to discharge. 5 of 23 infants on mechanical ventilation at 48 h of age were on air at 36 weeks postmenstrual age, and 12 of 26 of those were on nCPAP at 48 h of age. The probability of an individual baby remaining on nCPAP was 66% (95% CI 46% to 86%) on day 1 and 80% (95% CI 60% to 99%) on day 2. The smallest infant to be successfully extubated was 660 g and the youngest gestational age was 23.8 weeks. Conclusions Extremely preterm infants can be extubated to nCPAP soon after delivery, with a reasonable probability of not requiring immediate reintubation. PMID

  6. Distending Pressure Did Not Activate Acute Phase or Inflammatory Responses in the Airways and Lungs of Fetal, Preterm Lambs

    PubMed Central

    Petersen, Rebecca Y.; Royse, Emily; Kemp, Matthew W.; Miura, Yuichiro; Noe, Andres; Jobe, Alan H.; Hillman, Noah H.

    2016-01-01

    Background Mechanical ventilation at birth causes airway injury and lung inflammation in preterm sheep. Continuous positive airway pressure (CPAP) is being increasingly used clinically to transition preterm infants at birth. Objective To test if distending pressures will activate acute phase reactants and inflammatory changes in the airways of fetal, preterm lambs. Methods The head and chest of fetal lambs at 128±1 day GA were surgically exteriorized. With placental circulation intact, fetal lambs were then randomized to one of five 15 minute interventions: PEEP of 0, 4, 8, 12, or 16 cmH2O. Recruitment volumes were recorded. Fetal lambs remained on placental support for 30 min after the intervention. The twins of each 0 cmH2O animal served as controls. Fetal lung fluid (FLF), bronchoalveolar lavage fluid (BAL), right mainstem bronchi and peripheral lung tissue were evaluated for inflammation. Results Recruitment volume increased from 0.4±0.04 mL/kg at 4 cmH2O to 2.4±0.3 mL/kg at 16 cmH2O. The lambs were surfactant deficient, and all pressures were below the opening inflection pressure on pressure-volume curve. mRNA expression of early response genes and pro-inflammatory cytokines did not increase in airway tissue or lung tissue at any pressure compared to controls. FLF and BAL also did not have increases in early response proteins. No histologic changes or Egr-1 activation was present at the pressures used. Conclusion Distending pressures as high as 16 cmH2O did not recruit lung volume at birth and did not increase markers of injury in the lung or airways in non-breathing preterm fetal sheep. PMID:27463520

  7. A Randomized Trial Comparing Efficacy of Bubble and Ventilator Derived Nasal CPAP in Very Low Birth Weight Neonates with Respiratory Distress

    PubMed Central

    Agarwal, Sheetal; Roy, Mahesh K.; Verma, Ankit

    2016-01-01

    Introduction Continuous Positive Airway Pressure (CPAP) has an established role in the care of Very Low Birth Weight (VLBW) babies with respiratory distress. Bubble CPAP (BCPAP) is a cheap alternative for countries where resources are limited. However, data comparing efficacy of BCPAP with conventional ventilator derived (VCPAP) is limited. Aim To compare CPAP failure rates between BCPAP and VCPAP among VLBW, with moderate respiratory distress. Secondary objectives were to compare the rates of Intraventricular Haemorrhage (IVH), pulmonary air leaks and deaths between the two groups and determine the predictors of CPAP failure. Materials and Methods VLBW babies with moderate respiratory distress (Silverman Anderson score 4-7), born or admitted in Neonatal Intensive Care Unit (NICU) within 28 days of life were randomized to receive either BCPAP (n=34) or VCPAP (n=34). CPAP failure rate in both the groups was compared. Results The baseline characteristics were similar in both the groups. Five out of 34 (14.70%) babies in BCPAP group and 11 out of 34 (32.35%) in VCPAP failed CPAP (p=0.08). IVH (BCPAP group 24% and VCPAP group 9%, p= 0.10) and mortality (BCPAP group 6% and VCPAP group 9%, p=0.642) were comparable in both the groups. Factors such as gestational age <30 weeks, weight <1000 grams, Respiratory Distress Syndrome (RDS), shock, pulmonary haemorrhage, Disseminated Intravascular Coagulation (DIC) and multi-organ dysfunction were significantly associated with CPAP failure in our study. Conclusion The CPAP failure rates in VLBW babies with moderate respiratory distress were found to be similar whether bubble CPAP or ventilator CPAP was used. There was no difference in complication rates of IVH or mortality with either method of CPAP. PMID:27790540

  8. Effectiveness of CPAP treatment in daytime function in sleep apnea syndrome: a randomized controlled study with an optimized placebo.

    PubMed

    Montserrat, J M; Ferrer, M; Hernandez, L; Farré, R; Vilagut, G; Navajas, D; Badia, J R; Carrasco, E; De Pablo, J; Ballester, E

    2001-08-15

    Application of continuous positive airway pressure (CPAP) as the standard treatment for sleep apnea/hypopnea syndrome (SAHS) is a moot point. Studies on the effectiveness of this treatment have been challenged because of the lack of a suitable placebo. The recent description of a true placebo (sham CPAP) prompted us to conduct a randomized trial of CPAP or placebo to assess the effectiveness of CPAP in improving SAHS-related symptoms and daytime function in patients with moderate to severe SAHS. Forty-eight patients, stratified in four groups according to severity, were randomly allocated into two treatment groups (optimal and sham CPAP) for a 6-wk period. Of these, 45 completed follow-up (91% males; age: 54 +/- 10 yr; body mass index [BMI]: 32 +/- 6 kg/m(2); apnea-hypopnea index [AHI]: 54 +/- 19 events/h; and Epworth Sleepiness Scale [ESS]: 16 +/- 5). The ESS, a questionnaire on SAHS-related symptoms, Functional Outcomes Sleep Questionnaire (FOSQ), and the Short Form Health Survey (SF-36) were completed at inclusion and after treatment. After 10 d of washout, the placebo group was treated with optimal CPAP and reassessed before and after optimal CPAP. The group receiving optimal CPAP when compared with the group with sham CPAP showed considerably greater improvement in the relief of sleepiness (-9.5 versus -2.3, p < 0.001), other SAHS-related symptoms (-18.5 versus -4.5, p < 0.001), vigilance (+8.5 versus +3.4, p = 0.009), and general productivity (+4.0 versus +0.5, p = 0.04) FOSQ scales. Both groups used a similar number of hours for the optimal and the sham CPAP (4.3 versus 4.5, (p = NS). The patients initially treated with placebo CPAP improved significantly more when optimal CPAP was applied for ESS (-2.3 versus -6.7, p < 0.001) and other sleep apnea syndrome (SAS)-related symptoms (-4.5 versus -11.2, p = 0.02). Our study provides strong evidence of the effectiveness of CPAP treatment in improving symptoms and perceived health status in moderate to severe SAHS.

  9. Clinical review: Biphasic positive airway pressure and airway pressure release ventilation

    PubMed Central

    Putensen, Christian; Wrigge, Hermann

    2004-01-01

    This review focuses on mechanical ventilation strategies that allow unsupported spontaneous breathing activity in any phase of the ventilatory cycle. By allowing patients with the acute respiratory distress syndrome to breathe spontaneously, one can expect improvements in gas exchange and systemic blood flow, based on findings from both experimental and clinical trials. In addition, by increasing end-expiratory lung volume, as occurs when using biphasic positive airway pressure or airway pressure release ventilation, recruitment of collapsed or consolidated lung is likely to occur, especially in juxtadiaphragmatic lung legions. Traditional approaches to mechanical ventilatory support of patients with acute respiratory distress syndrome require adaptation of the patient to the mechanical ventilator using heavy sedation and even muscle relaxation. Recent investigations have questioned the utility of sedation, muscle paralysis and mechanical control of ventilation. Furthermore, evidence exists that lowering sedation levels will decrease the duration of mechanical ventilatory support, length of stay in the intensive care unit, and overall costs of hospitalization. Based on currently available data, we suggest considering the use of techniques of mechanical ventilatory support that maintain, rather than suppress, spontaneous ventilatory effort, especially in patients with severe pulmonary dysfunction. PMID:15566621

  10. Early CPAP versus Surfactant in Extremely Preterm Infants

    PubMed Central

    2011-01-01

    Background There are limited data to inform the choice between early treatment with continuous positive airway pressure (CPAP) and early surfactant treatment as the initial support for extremely-low-birth-weight infants. Methods We performed a randomized, multicenter trial, with a 2-by-2 factorial design, involving infants who were born between 24 weeks 0 days and 27 weeks 6 days of gestation. Infants were randomly assigned to intubation and surfactant treatment (within 1 hour after birth) or to CPAP treatment initiated in the delivery room, with subsequent use of a protocol-driven limited ventilation strategy. Infants were also randomly assigned to one of two target ranges of oxygen saturation. The primary outcome was death or bronchopulmonary dysplasia as defined by the requirement for supplemental oxygen at 36 weeks (with an attempt at withdrawal of supplemental oxygen in neonates who were receiving less than 30% oxygen). Results A total of 1316 infants were enrolled in the study. The rates of the primary outcome did not differ significantly between the CPAP group and the surfactant group (47.8% and 51.0%, respectively; relative risk with CPAP, 0.95; 95% confidence interval [CI], 0.85 to 1.05) after adjustment for gestational age, center, and familial clustering. The results were similar when bronchopulmonary dysplasia was defined according to the need for any supplemental oxygen at 36 weeks (rates of primary outcome, 48.7% and 54.1%, respectively; relative risk with CPAP, 0.91; 95% CI, 0.83 to 1.01). Infants who received CPAP treatment, as compared with infants who received surfactant treatment, less frequently required intubation or postnatal corticosteroids for bronchopulmonary dysplasia (P<0.001), required fewer days of mechanical ventilation (P = 0.03), and were more likely to be alive and free from the need for mechanical ventilation by day 7 (P = 0.01). The rates of other adverse neonatal outcomes did not differ significantly between the two groups

  11. Upper Airway Elasticity Estimation in Pediatric Down Syndrome Sleep Apnea Patients Using Collapsible Tube Theory.

    PubMed

    Subramaniam, Dhananjay Radhakrishnan; Mylavarapu, Goutham; McConnell, Keith; Fleck, Robert J; Shott, Sally R; Amin, Raouf S; Gutmark, Ephraim J

    2016-05-01

    Elasticity of the soft tissues surrounding the upper airway lumen is one of the important factors contributing to upper airway disorders such as snoring and obstructive sleep apnea. The objective of this study is to calculate patient specific elasticity of the pharynx from magnetic resonance (MR) images using a 'tube law', i.e., the relationship between airway cross-sectional area and transmural pressure difference. MR imaging was performed under anesthesia in children with Down syndrome (DS) and obstructive sleep apnea (OSA). An airway segmentation algorithm was employed to evaluate changes in airway cross-sectional area dilated by continuous positive airway pressure (CPAP). A pressure-area relation was used to make localized estimates of airway wall stiffness for each patient. Optimized values of patient specific Young's modulus for tissue in the velopharynx and oropharynx, were estimated from finite element simulations of airway collapse. Patient specific deformation of the airway wall under CPAP was found to exhibit either a non-linear 'hardening' or 'softening' behavior. The localized airway and tissue elasticity were found to increase with increasing severity of OSA. Elasticity based patient phenotyping can potentially assist clinicians in decision making on CPAP and airway or tissue elasticity can supplement well-known clinical measures of OSA severity.

  12. A New Animal Model of Obstructive Sleep Apnea Responding to Continuous Positive Airway Pressure

    PubMed Central

    Neuzeret, Pierre-Charles; Gormand, Frédéric; Reix, Philippe; Parrot, Sandrine; Sastre, Jean-Pierre; Buda, Colette; Guidon, Gérard; Sakai, Kazuya; Lin, Jian-Sheng

    2011-01-01

    Study Objectives: An improved animal model of obstructive sleep apnea (OSA) is needed for the development of effective pharmacotherapies. In humans, flexion of the neck and a supine position, two main pathogenic factors during human sleep, are associated with substantially greater OSA severity. We postulated that these two factors might generate OSA in animals. Design: We developed a restraining device for conditioning to investigate the effect of the combination of 2 body positions—prone (P) or supine (S)—and 2 head positions—with the neck flexed at right angles to the body (90°) or in extension in line with the body (180°)—during sleep in 6 cats. Polysomnography was performed twice on each cat in each of the 4 sleeping positions—P180, S180, P90, or S90. The effect of continuous positive airway pressure (CPAP) treatment was then investigated in 2 cats under the most pathogenic condition. Setting: NA. Patients or Participants: NA. Interventions: NA. Measurements and Results: Positions P180 and, S90 resulted, respectively, in the lowest and highest apnea-hypopnea index (AHI) (3 ± 1 vs 25 ± 2, P < 0.001), while P90 (18 ± 3, P < 0.001) and S180 (13 ± 5, P < 0.01) gave intermediate values. In position S90, an increase in slow wave sleep stage 1 (28% ± 3% vs 22% ± 3%, P < 0.05) and a decrease in REM sleep (10% ± 2% vs 18% ± 2%, P < 0.001) were also observed. CPAP resulted in a reduction in the AHI (8 ± 1 vs 27 ± 3, P < 0.01), with the added benefit of sleep consolidation. Conclusion: By mimicking human pathogenic sleep conditions, we have developed a new reversible animal model of OSA. Citation: Neuzeret PC; Gormand F; Reix P; Parrot S; Sastre JP; Buda C; Guidon G; Sakai K; Lin JS. A new animal model of obstructive sleep apnea responding to continuous positive airway pressure. SLEEP 2011;34(4):541-548. PMID:21461333

  13. Efficacy of a Low-Cost Bubble CPAP System in Treatment of Respiratory Distress in a Neonatal Ward in Malawi

    PubMed Central

    Kawaza, Kondwani; Machen, Heather E.; Brown, Jocelyn; Mwanza, Zondiwe; Iniguez, Suzanne; Gest, Al; Smith, E. O'Brian; Oden, Maria; Richards-Kortum, Rebecca R.; Molyneux, Elizabeth

    2014-01-01

    Background Respiratory failure is a leading cause of neonatal mortality in the developing world. Bubble continuous positive airway pressure (bCPAP) is a safe, effective intervention for infants with respiratory distress and is widely used in developed countries. Because of its high cost, bCPAP is not widely utilized in low-resource settings. We evaluated the performance of a new bCPAP system to treat severe respiratory distress in a low resource setting, comparing it to nasal oxygen therapy, the current standard of care. Methods We conducted a non-randomized convenience sample study to test the efficacy of a low-cost bCPAP system treating newborns with severe respiratory distress in the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi. Neonates weighing >1,000 g and presenting with severe respiratory distress who fulfilled inclusion criteria received nasal bCPAP if a device was available; if not, they received standard care. Clinical assessments were made during treatment and outcomes compared for the two groups. Findings 87 neonates (62 bCPAP, 25 controls) were recruited. Survival rate for neonates receiving bCPAP was 71.0% (44/62) compared with 44.0% (11/25) for controls. 65.5% (19/29) of very low birth weight neonates receiving bCPAP survived to discharge compared to 15.4% (1/13) of controls. 64.6% (31/48) of neonates with respiratory distress syndrome (RDS) receiving bCPAP survived to discharge, compared to 23.5% (4/17) of controls. 61.5% (16/26) of neonates with sepsis receiving bCPAP survived to discharge, while none of the seven neonates with sepsis in the control group survived. Interpretation Use of a low-cost bCPAP system to treat neonatal respiratory distress resulted in 27% absolute improvement in survival. The beneficial effect was greater for neonates with very low birth weight, RDS, or sepsis. Implementing appropriate bCPAP devices could reduce neonatal mortality in developing countries. PMID:24489715

  14. A Pilot Study on the Efficacy of Continuous Positive Airway Pressure on the Manifestations of Ménière's Disease in Patients with Concomitant Obstructive Sleep Apnea Syndrome

    PubMed Central

    Nakayama, Meiho; Masuda, Ayako; Ando, Kayoko Bhardwaj; Arima, Sachie; Kabaya, Kayoko; Inagaki, Akira; Nakamura, Yoshihisa; Suzuki, Motohiko; Brodie, Hilary; Diaz, Rodney C.; Murakami, Shingo

    2015-01-01

    Objective: To evaluate the effect of continuous positive airway pressure (CPAP) therapy on Ménière's disease patients with concomitant obstructive sleep apnea syndrome (OSAS), since recent reports suggest OSAS may cause dysfunction of the vestibular system. Study Design: Prospective study using CPAP administered to patients diagnosed with “Definite Ménière's disease” according to the guidelines of the American Academy of Otolaryngology— Head and Neck Surgery and combined with OSAS. Setting: University hospital. Methods: Twenty consecutive patients, 14 male and 6 female with active, unilateral, cochleovestibular Ménière's disease refractory to medical management who also had concurrent OSAS as defined by International Classification of Sleep Disorders, Second Edition were selected to undergo solitary CPAP therapy. Audiometric testing, caloric testing, and DHI survey were conducted before and after CPAP therapy and compared to assess effectiveness of CPAP therapy as utilized for treatment of Ménière's disease. Results: Although caloric testing did not show significant difference, audiometric testing and results of dizziness handicap inventory were significantly improved (p < 0.05) after CPAP therapy only, without standard treatment for Ménière's disease. Conclusions: Recent reports have suggested that OSAS may cause dysfunction of the vestibular system. We investigated whether standard therapy for OSAS would be of benefit in the management of vertigo and hearing loss in Ménière's disease patients. Our study cohort demonstrated significant improvement in both DHI and audiometric testing following solitary CPAP therapy for OSAS. Solitary CPAP therapy may become a new effective treatment strategy for Ménière's disease patients with OSAS, not just only for control of dizziness and vertigo but also for potential benefit of hearing. Citation: Nakayama M, Masuda A, Ando KB, Arima S, Kabaya K, Inagaki A, Nakamura Y, Suzuki M, Brodie H, Diaz RC, Murakami S

  15. Influence of sleep on response to negative airway pressure of tensor palatini muscle and retropalatal airway.

    PubMed

    Wheatley, J R; Tangel, D J; Mezzanotte, W S; White, D P

    1993-11-01

    Increased retropalatal airway resistance may be caused by a sleep-induced loss of palatal muscle activity and a diminished ability of these muscles to respond to the increasing intrapharyngeal negative pressure that develops during sleep. To investigate these possibilities, in six normal subjects, we determined the effect of non-rapid-eye-movement sleep on 1) the tensor palatini (TP) electromyogram (EMG) response to rapid-onset negative-pressure generations (NPG) in the upper airway and 2) the collapsibility of the retropalatal airway during these NPGs. During wakefulness, the change in TP EMG from basal to peak levels (during NPG) was 19.8 +/- 3.2 arbitrary units (P < 0.005). This was markedly reduced during sleep (3.6 +/- 1.5 arbitrary units; P < 0.001). The latency of the TP EMG response was 48.5 +/- 5.6 ms during wakefulness but was prolonged during sleep (105.0 +/- 12.2 ms; P < 0.02). The peak transpalatal pressure during NPG (a measure of airway collapse) was 2.1 +/- 0.7 cmH2O during wakefulness and increased to 5.3 +/- 0.8 cmH2O during sleep (P < 0.05). We conclude that the brisk reflex response of the TP muscle to negative pressure during wakefulness is markedly reduced during non-rapid-eye-movement sleep, in association with a more collapsible retropalatal airway. We speculate that the reduction in this TP reflex response contributes to retropalatal airway narrowing during sleep in normal subjects.

  16. The importance of administration of early surfactant and nasal continuous positive airway pressure in newborns with respiratory distress syndrome

    PubMed Central

    Ceylan, Abdullah; Gezer, Suat; Demir, Nihat; Tuncer, Oğuz; Peker, Erdal; Kırımi, Ercan

    2014-01-01

    Aim: Mechanical ventilation is an invasive method and causes to important problems in the respiratory tract and lung parenchyma. The objective of our study was to investigate if administration of early surfactant and nasal continuous positive airway pressure (nCPAP) was superior to delayed surfactant administration and mechanical ventilation. Material and Methods: The study was conducted in the Van 100th Year University, Medical Faculty Hospital, Neonatal Intensive Care Unit. One hundred and nine infants with respiratory distrss syndrome (RDS) with a gestational age of 32 weeks and/or below were included in the study. Surfactant was given to 61 infants in the delivery room or intensive care unit and subsequently nCPAP was administered. Surfactant was administered in 48 infants in the control group and mechanical ventilation was inititated subsequently. Informed consent was obtained from the relatives of all patients and ethics committee approval was also obtained (Approval number: 03.02.2011/15). Results: There was no statistically significant difference between the two groups in terms of gestational age, birth weight, gender, height and head circumference measurements (p>0.05). The mean hospitalization time in the patients in the study group was 24.4±17.8 days, whereas the mean time of nCPAP was 28.4 (4–120) hours. In the study group, intracranial hemorrhage was found with a rate of 27.85%, bronchopulmonary dysplasia was found with a rate of 4.91%, pneumothorax was found with a rate of 3.27%, necrotizing enterocolitis was found with a rate of 3.27%, patent ductus arteriosus was found with a rate of 16.39, sepsis was found with a rate of 22.95% and retinopathy of prematurity was found with a rate of 1.63%. No statistically significant difference was found between the study and control groups in terms of the rates of complications. During the follow-up period, 17 (27.86%) patients were lost. The length of stay on mechanical ventilation in the study group was

  17. Erectile Dysfunction and Sexual Hormone Levels in Men With Obstructive Sleep Apnea: Efficacy of Continuous Positive Airway Pressure.

    PubMed

    Zhang, Xiao-Bin; Lin, Qi-Chang; Zeng, Hui-Qing; Jiang, Xing-Tang; Chen, Bo; Chen, Xiao

    2016-01-01

    In this study, the prevalence of erectile dysfunction (ED) and serum sexual hormone levels were evaluated in men with obstructive sleep apnea (OSA). In these patients, the efficacy of continuous positive airway pressure (CPAP) was determined. The 207 men (mean age 44.0 ± 11.1 years) enrolled in the study were stratified within four groups based on their apnea-hypopnea index score: simple snoring (n = 32), mild OSA (n = 29), moderate OSA (n = 38), and severe OSA (n = 108). The International Index of Erectile Dysfunction-5 (IIEF-5) score was obtained from each patient, and blood samples for the analysis of sexual hormones (prolactin, luteotropin, follicle-stimulating hormone, estradiol, progestin, and testosterone) were drawn in the morning after polysomnography. The IIEF-5 test and serum sexual hormone measurements were repeated after 3 months of CPAP treatment in 53 men with severe OSA. The prevalence of ED was 60.6 % in OSA patients overall and 72.2 % in those with severe OSA. Compared with the simple snoring group, patients with severe OSA had significantly lower testosterone levels (14.06 ± 5.62 vs. 17.02 ± 4.68, p = .018) and lower IIEF-5 scores (16.33 ± 6.50 vs. 24.09 ± 1.94, p = .001). The differences in the other sexual hormones between groups were not significant. After 3 months of CPAP treatment, there were no significant changes in sexual hormone levels, but the IIEF-5 score had improved significantly (18.21 ± 4.05 vs. 19.21 ± 3.86, p = .001). Severe OSA patients have low testosterone concentration and high ED prevalence. IIEF-5 scores increased significantly after CPAP treatment, but there was no effect on serum testosterone levels.

  18. A Comparison of Different Success Definitions in Non-Continuous Positive Airway Pressure Treatment for Obstructive Sleep Apnea Using Cardiopulmonary Coupling

    PubMed Central

    Lee, Woo Hyun; Hong, Seung-No; Kim, Hong Joong; Rhee, Chae-Seo; Lee, Chul Hee; Yoon, In-Young; Kim, Jeong-Whun

    2016-01-01

    Study Objectives: The definition and the criteria for the successful treatment of obstructive sleep apnea vary, depending on the study. This study aimed to compare different success criteria of non-continuous positive airway pressure (non-CPAP) treatment for obstructive sleep apnea in terms of sleep quality by using cardiopulmonary coupling. Methods: We included 98 patients who had been treated with sleep surgery or with a mandibular advancement device at our sleep clinic from January 2011 to March 2013. The success and failure groups were divided by 6 criteria that have been used in the literature. The validity of each of the 6 criteria was evaluated by cardiopulmonary coupling-based sleep quality. Results: The parameters of cardiopulmonary coupling indicated that sleep quality improved with non-CPAP treatment: low-frequency coupling decreased from 57.4% ± 17.7% to 46.9% ± 16.5%, whereas high-frequency coupling increased from 30.2% ± 17.1% to 37.4% ± 16.7%. In multiple regression analysis, only the criterion of a reduction in the apnea-hypopnea index greater than 50% was significantly associated with sleep quality improvement (p = 0.016; 95% confidence interval, 1.008–1.076 in the high-frequency coupling increment; p = 0.001; 95% confidence interval, 1.025–1.099 in the low-frequency coupling decrement). Conclusions: Cardiopulmonary coupling analysis showed that a reduction in the apnea-hypopnea index of more than 50% might be the optimal criterion to determine the success or failure of non-CPAP treatment in terms of sleep quality. Citation: Lee WH, Hong SN, Kim HJ, Rhee CS, Lee CH, Yoon IY, Kim JW. A comparison of different success definitions in non-continuous positive airway pressure treatment for obstructive sleep apnea using cardiopulmonary coupling. J Clin Sleep Med 2016;12(1):35–41. PMID:26235153

  19. Continuous Positive Airway Pressure Increases Pulsatile Growth Hormone Secretion and Circulating Insulin-like Growth Factor-1 in a Time-Dependent Manner in Men With Obstructive Sleep Apnea: A Randomized Sham-Controlled Study

    PubMed Central

    Hoyos, Camilla M.; Killick, Roo; Keenan, Daniel M.; Baxter, Robert C.; Veldhuis, Johannes D.; Liu, Peter Y.

    2014-01-01

    Study Objectives: To assess the time-dependent effect of continuous positive airway pressure (CPAP), on insulin-like growth factor-1 (IGF-1), IGF binding proteins (IGFBPs) and pulsatile growth hormone (GH) secretion. Design: A randomized, double-blind, sham-controlled, parallel group study. Participants: Sixty-five middle-aged men with moderate to severe obstructive sleep apnea. Intervention: Active (n = 34) or sham (n = 31) CPAP for 12 weeks, followed by 12 weeks of active CPAP (n = 65). Measurements and Results: Fasting morning IGF-1, IGFBP-3, and IGFBP-1 blood levels at 0, 6, 12, and 24 weeks. Overnight GH secretion was calculated by mathematical deconvolution of serial GH measurements from serum samples collected every 10 min (22:00-06:00) during simultaneous polysomnography in a subset of 18 men (active n = 11, sham n = 7) at week 12. Active, compared with sham, CPAP increased IGF-1 at 12 weeks (P = 0.006), but not at 6 weeks (P = 0.44). Changes in IGFBP-3 and IGFBP-1 were not different between groups at 6 or 12 weeks (all P ≥ 0.15). At week 24, there was a further increase in IGF-1 and a decrease in IGFBP-1 in the pooled group (P = 0.0001 and 0.046, respectively). In the subset, total (P = 0.001) and pulsatile (P = 0.002) GH secretion, mean GH concentration (P = 0.002), mass of GH secreted per pulse (P = 0.01) and pulse frequency (P = 0.04) were all higher after 12 weeks of CPAP compared with sham. Basal secretion, interpulse regularity, and GH regularity were not different between groups (all P > 0.11). Conclusions: Twelve weeks, but not 6 weeks, of CPAP increases IGF-1, with a further increase after 24 weeks. Total and pulsatile GH secretion, secretory burst mass and pulse frequency are also increased by 12 weeks. CPAP improves specific elements of the GH/IGF-1 axis in a time-dependent manner. Clinical Trials Registration: Australia New Zealand Clinical Trials Network, www.anzctr.org.au, number ACTRN12608000301369. Citation: Hoyos CM; Killick R; Keenan DM

  20. Prolonged positive airway pressure for severe neonatal tracheobronchomalacia.

    PubMed Central

    Pizer, B L; Freeland, A P; Wilkinson, A R

    1986-01-01

    A very low birthweight preterm baby with respiratory distress at birth was found to have severe congenital tracheobronchomalacia. Continuous positive airway pressure was given through an endotracheal tube without tracheostomy for 15 weeks before unassisted respiration could be maintained. Diagnosis was made and progress monitored by laryngobronchoscopy on three occasions. PMID:3532962

  1. Prolonged positive airway pressure for severe neonatal tracheobronchomalacia.

    PubMed

    Pizer, B L; Freeland, A P; Wilkinson, A R

    1986-09-01

    A very low birthweight preterm baby with respiratory distress at birth was found to have severe congenital tracheobronchomalacia. Continuous positive airway pressure was given through an endotracheal tube without tracheostomy for 15 weeks before unassisted respiration could be maintained. Diagnosis was made and progress monitored by laryngobronchoscopy on three occasions.

  2. Clinical effectiveness and cost-effectiveness results from the randomised controlled Trial of Oral Mandibular Advancement Devices for Obstructive sleep apnoea-hypopnoea (TOMADO) and long-term economic analysis of oral devices and continuous positive airway pressure.

    PubMed Central

    Sharples, Linda; Glover, Matthew; Clutterbuck-James, Abigail; Bennett, Maxine; Jordan, Jake; Chadwick, Rebecca; Pittman, Marcus; East, Clare; Cameron, Malcolm; Davies, Mike; Oscroft, Nick; Smith, Ian; Morrell, Mary; Fox-Rushby, Julia; Quinnell, Timothy

    2014-01-01

    BACKGROUND Obstructive sleep apnoea-hypopnoea (OSAH) causes excessive daytime sleepiness (EDS), impairs quality of life (QoL) and increases cardiovascular disease and road traffic accident risks. Continuous positive airway pressure (CPAP) treatment is clinically effective but undermined by intolerance, and its cost-effectiveness is borderline in milder cases. Mandibular advancement devices (MADs) are another option, but evidence is lacking regarding their clinical effectiveness and cost-effectiveness in milder disease. OBJECTIVES (1) Conduct a randomised controlled trial (RCT) examining the clinical effectiveness and cost-effectiveness of MADs against no treatment in mild to moderate OSAH. (2) Update systematic reviews and an existing health economic decision model with data from the Trial of Oral Mandibular Advancement Devices for Obstructive sleep apnoea-hypopnoea (TOMADO) and newly published results to better inform long-term clinical effectiveness and cost-effectiveness of MADs and CPAP in mild to moderate OSAH. TOMADO A crossover RCT comparing clinical effectiveness and cost-effectiveness of three MADs: self-moulded [SleepPro 1™ (SP1); Meditas Ltd, Winchester, UK]; semibespoke [SleepPro 2™ (SP2); Meditas Ltd, Winchester, UK]; and fully bespoke [bespoke MAD (bMAD); NHS Oral-Maxillofacial Laboratory, Addenbrooke's Hospital, Cambridge, UK] against no treatment, in 90 adults with mild to moderate OSAH. All devices improved primary outcome [apnoea-hypopnoea index (AHI)] compared with no treatment: relative risk 0.74 [95% confidence interval (CI) 0.62 to 0.89] for SP1; relative risk 0.67 (95% CI 0.59 to 0.76) for SP2; and relative risk 0.64 (95% CI 0.55 to 0.76) for bMAD (p < 0.001). Differences between MADs were not significant. Sleepiness [as measured by the Epworth Sleepiness Scale (ESS)] was scored 1.51 [95% CI 0.73 to 2.29 (SP1)] to 2.37 [95% CI 1.53 to 3.22 (bMAD)] lower than no treatment (p < 0.001), with SP2 and bMAD significantly better than SP1

  3. Impact of CPAP on physical exercise tolerance and sympathetic-vagal balance in patients with chronic heart failure

    PubMed Central

    Reis, Hugo V.; Borghi-Silva, Audrey; Catai, Aparecida M.; Reis, Michel S.

    2014-01-01

    Background: Chronic heart failure (CHF) leads to exercise intolerance. However, non-invasive ventilation is able to improve functional capacity of patients with CHF. Objectives: The aim of this study was to evaluate the effectiveness of continuous positive airway pressure (CPAP) on physical exercise tolerance and heart rate variability (HRV) in patients with CHF. Method : Seven men with CHF (62±8 years) and left ventricle ejection fraction of 41±8% were submitted to an incremental symptom-limited exercise test (IT) on the cicloergometer. On separate days, patients were randomized to perform four constant work rate exercise tests to maximal tolerance with and without CPAP (5 cmH2O) in the following conditions: i) at 50% of peak work rate of IT; and ii) at 75% of peak work rate of IT. At rest and during these conditions, instantaneous heart rate (HR) was recorded using a cardiofrequencimeter and HRV was analyzed in time domain (SDNN and RMSSD indexes). For statistical procedures, Wilcoxon test or Kruskall-Wallis test with Dunn's post-hoc were used accordingly. In addition, categorical variables were analysed through Fischer's test (p<0.05). Results: There were significant improvements in exercise tolerance at 75% of peak work rate of IT with CPAP (405±52 vs. 438±58 s). RMSSD indexes were lower during exercise tests compared to CPAP at rest and with 50% of peak work rate of IT. Conclusion: These data suggest that CPAP appears to be a useful strategy to improve functional capacity in patients with CHF. However, the positive impact of CPAP did not generate significant changes in the HRV during physical exercises. PMID:25003274

  4. Helmet CPAP versus Oxygen Therapy in Hypoxemic Acute Respiratory Failure: A Meta-Analysis of Randomized Controlled Trials

    PubMed Central

    Luo, Yuwen; Luo, Yan; Li, Yun; Zhou, Luqian; Zhu, Zhe; Chen, Yitai; Huang, Yuxia

    2016-01-01

    Purpose The efficacy of helmet continuous positive airway pressure (CPAP) in hypoxemic acute respiratory failure (hARF) remains unclear. The aim of this meta-analysis was to critically review studies that investigated the effect of helmet CPAP on gas exchange, mortality, and intubation rate in comparison with standard oxygen therapy. Materials and Methods We performed a meta-analysis of randomized controlled trials (RCTs) by searching the PubMed, Embase, Cochrane library, OVID, and CBM databases, and the bibliographies of the retrieved articles. Studies that enrolled adults with hARF who were treated with helmet CPAP and measured at least one of the following parameters were included: gas exchange, intubation rate, in-hospital mortality rate. Results Four studies with 377 subjects met the inclusion criteria and were analyzed. Compared to the standard oxygen therapy, helmet CPAP significantly increased the PaO2/FiO2 [weighted mean difference (WMD)=73.40, 95% confidence interval (95% CI): 43.92 to 102.87, p<0.00001], and decreased the arterial carbon dioxide levels (WMD=-1.92, 95% CI: -3.21 to -0.63, p=0.003), intubation rate [relative risk (RR)=0.21, 95% CI: 0.11 to 0.40, p<0.00001], and in-hospital mortality rate (RR=0.22, 95% CI: 0.09 to 0.50, p=0.0004). Conclusion The results of this meta-analysis suggest that helmet CPAP improves oxygenation and reduces mortality and intubation rates in hARF. However, the significant clinical and statistical heterogeneity of the literature implies that large RCTs are needed to determine the role of helmet CPAP in different hypoxemic ARF populations. PMID:27189288

  5. Management of obstructive sleep apnea by continuous positive airway pressure.

    PubMed

    Weaver, Terri E; Sawyer, Amy

    2009-11-01

    Obstructive sleep apnea (OSA) is a common problem, with 9% to 28% of women and 24% to 26% of males having apneic events at a treatable level, making this syndrome a serious public health issue. This article describes the outcomes associated with continuous positive airway pressure treatment, significance of the issue of poor adherence in OSA, discusses evidence regarding the optimal duration of nightly use, describes the nature and predictors of nonadherence, and reviews interventions that have been tested to increase nightly use and suggests management strategies.

  6. Clinical effectiveness and cost-effectiveness results from the randomised controlled Trial of Oral Mandibular Advancement Devices for Obstructive sleep apnoea-hypopnoea (TOMADO) and long-term economic analysis of oral devices and continuous positive airway pressure.

    PubMed Central

    Sharples, Linda; Glover, Matthew; Clutterbuck-James, Abigail; Bennett, Maxine; Jordan, Jake; Chadwick, Rebecca; Pittman, Marcus; East, Clare; Cameron, Malcolm; Davies, Mike; Oscroft, Nick; Smith, Ian; Morrell, Mary; Fox-Rushby, Julia; Quinnell, Timothy

    2014-01-01

    BACKGROUND Obstructive sleep apnoea-hypopnoea (OSAH) causes excessive daytime sleepiness (EDS), impairs quality of life (QoL) and increases cardiovascular disease and road traffic accident risks. Continuous positive airway pressure (CPAP) treatment is clinically effective but undermined by intolerance, and its cost-effectiveness is borderline in milder cases. Mandibular advancement devices (MADs) are another option, but evidence is lacking regarding their clinical effectiveness and cost-effectiveness in milder disease. OBJECTIVES (1) Conduct a randomised controlled trial (RCT) examining the clinical effectiveness and cost-effectiveness of MADs against no treatment in mild to moderate OSAH. (2) Update systematic reviews and an existing health economic decision model with data from the Trial of Oral Mandibular Advancement Devices for Obstructive sleep apnoea-hypopnoea (TOMADO) and newly published results to better inform long-term clinical effectiveness and cost-effectiveness of MADs and CPAP in mild to moderate OSAH. TOMADO A crossover RCT comparing clinical effectiveness and cost-effectiveness of three MADs: self-moulded [SleepPro 1™ (SP1); Meditas Ltd, Winchester, UK]; semibespoke [SleepPro 2™ (SP2); Meditas Ltd, Winchester, UK]; and fully bespoke [bespoke MAD (bMAD); NHS Oral-Maxillofacial Laboratory, Addenbrooke's Hospital, Cambridge, UK] against no treatment, in 90 adults with mild to moderate OSAH. All devices improved primary outcome [apnoea-hypopnoea index (AHI)] compared with no treatment: relative risk 0.74 [95% confidence interval (CI) 0.62 to 0.89] for SP1; relative risk 0.67 (95% CI 0.59 to 0.76) for SP2; and relative risk 0.64 (95% CI 0.55 to 0.76) for bMAD (p < 0.001). Differences between MADs were not significant. Sleepiness [as measured by the Epworth Sleepiness Scale (ESS)] was scored 1.51 [95% CI 0.73 to 2.29 (SP1)] to 2.37 [95% CI 1.53 to 3.22 (bMAD)] lower than no treatment (p < 0.001), with SP2 and bMAD significantly better than SP1

  7. How does serum brain natriuretic peptide level change under nasal continuous positive airway pressure in obstructive sleep apnea-hypopnea syndrome?

    PubMed Central

    Msaad, Sameh; Marrakchi, Rim; Grati, Malek; Gargouri, Rahma; Kammoun, Samy; Jammoussi, Kamel; Yangui, Ilhem

    2016-01-01

    Background Obstructive sleep apnea-hypopnea syndrome (OSAHS) is associated with cardiovascular morbidity and mortality, which can be improved by using continuous positive airway pressure (CPAP) therapy. However, the pathophysiological links between the two kinds of disease and the mechanism of the CPAP effect remain incompletely understood. We aimed to inquire into the myocardial involvement in this relationship. We suggested that serum brain natriuretic peptide (BNP) is sensitive enough to detect myocardial stress caused by OSAHS. Design and methods Sixty-four subjects without cardiovascular disease (21 controls, 24 normotensive OSAHS patients, and 19 hypertensive OSAHS patients) were analyzed for serum BNP at baseline and serially over 6 months. CPAP was applied to 23 patients with severe OSAHS. Results At baseline, the serum BNP levels were significantly higher (p=0.0001) in the OSAHS group (22.3±14.79 pg/ml) than in the control group (9.2±6.75 pg/ml). Increased serum BNP levels were significantly associated with mean transcutaneous oxygen saturation (SpO2) (p<0.0001), minimal SpO2 (p=0.002), oxygen desaturation index (p=0.001), and total sleep time spent with SpO2 lower than 90% (p=0.002). All patients with elevated BNP levels (≥37 pg/ml) had moderate or severe OSAHS (11/43 OSAHS patients). The more severe the OSAHS, the higher the BNP levels were. However, only the difference between severe and mild OSAHS was statistically significant (p=0.029). Hypertensive OSAHS patients had the highest baseline BNP levels (27.7±16.74 pg/ml). They were significantly higher (p=0.001) than in normotensive OSAHS patients (18±11.72 pg/ml) (p=0.039) and the controls (9.2±6.75 pg/ml). As compared with baseline, treatment with CPAP significantly decreased BNP levels in both hypertensive and normotensive OSAHS patients (respectively, from 36±16.10 to 29.7±14.29 pg/ml, p<0.001, and from 20±10.09 to 16±8.98 pg/ml, p<0.001). In contrast, the BNP levels slightly increased in

  8. Nasal CPAP in the delivery room for newborns with extremely low birth weight in a hospital in a developing country

    PubMed Central

    Gonçalves-Ferri, W.A.; Martinez, F.E.

    2013-01-01

    The objective of this study was to determine the feasibility of the use of continuous positive airway pressure installed prophylactically in the delivery room (DR-CPAP), for infants with a birth weight between 500 and 1000 g in settings with limited resources. During 23 months, infants with a birth weight between 500 and 1000 g consecutively received DR-CPAP. A total of 33 infants with low birth weight were enrolled, 16 (48.5%) were females. Only 14 (42.4%) received antenatal corticosteroids and only 2 of those 14 (14.3%) infants weighing 500-750 g were not intubated in the delivery room, and apnea was given as the reason for intubation of these patients. Of the 19 infants in the 751-1000 g weight range, 9 (47.4%) were intubated in the delivery room, 6 due to apnea and 3 due to respiratory discomfort. For DR-CPAP to be successful, it is probably necessary for preterm babies to be more prepared at birth to withstand the respiratory effort without the need for intubation. Antenatal corticosteroids and better prenatal monitoring are fundamental for success of DR-CPAP. PMID:24141616

  9. A pilot study investigating the effects of continuous positive airway pressure treatment and weight-loss surgery on autonomic activity in obese obstructive sleep apnea patients☆, ☆☆

    PubMed Central

    Bakker, Jessie P.; Campana, Lisa M.; Montesi, Sydney B.; Balachandran, Jayshankar; DeYoung, Pamela N.; Smales, Erik; Patel, Sanjay R.; Malhotra, Atul

    2015-01-01

    Background We have previously demonstrated that severity of obstructive sleep apnea (OSA) as measured by the apnea–hypopnea index (AHI) is a significant independent predictor of readily-computed time-domain metrics of short-term heart rate variability (HRV). Methods We aimed to assess time-domain HRV measured over 5-min while awake in a trial of obese subjects undergoing one of two OSA therapies: weight-loss surgery (n = 12, 2 males, median and interquartile range (IQR) for BMI 43.7 [42.0, 51.4] kg/m2, and AHI 18.1 [16.3, 67.5] events/h) or continuous positive airway pressure (CPAP) (n = 15, 11 males, median BMI 33.8 [31.3, 37.9] kg/m2, and AHI 36.5 [24.7, 77.3] events/h). Polysomnography was followed by electrocardiography during wakefulness; measurements were repeated at 6 and 12–18 months post-intervention. Results Despite similar measurements at baseline, subjects who underwent surgery exhibited greater improvement in short-term HRV than those who underwent CPAP (p = 0.04). Conclusions Our data suggest a possible divergence in autonomic function between the effects of weight loss resulting from bariatric surgery, and the amelioration of obstructive respiratory events resulting from CPAP treatment. Randomized studies are necessary before clinical recommendations can be made. PMID:24636793

  10. Validation of airway resistance models for predicting pressure loss through anatomically realistic conducting airway replicas of adults and children.

    PubMed

    Borojeni, Azadeh A T; Noga, Michelle L; Martin, Andrew R; Finlay, Warren H

    2015-07-16

    This work describes in vitro measurement of the total pressure loss at varying flow rate through anatomically realistic conducting airway replicas of 10 children, 4 to 8 years old, and 5 adults. Experimental results were compared with analytical predictions made using published airway resistance models. For the adult replicas, the model proposed by van Ertbruggen et al. (2005. J. Appl. Physiol. 98, 970-980) most accurately predicted central conducting airway resistance for inspiratory flow rates ranging from 15 to 90 L/min. Models proposed by Pedley et al. (1970. J. Respir. Physiol. 9, 371-386) and by Katz et al. (2011. J. Biomech. 44, 1137-1143) also provided reasonable estimates, but with a tendency to over predict measured pressure loss for both models. For child replicas, the Pedley and Katz models both provided good estimation of measured pressure loss at flow rates representative of resting tidal breathing, but under predicted measured values at high inspiratory flow rate (60 L/min). The van Ertbruggen model, developed based on flow simulations performed in an adult airway model, tended to under predict measured pressure loss through the child replicas across the range of flow rates studied (2 to 60 L/min). These results are intended to provide guidance for selection of analytical pressure loss models for use in predicting airway resistance and ventilation distribution in adults and children.

  11. Long-term effects of CPAP on daytime functioning in patients with sleep apnoea syndrome.

    PubMed

    Muñoz, A; Mayoralas, L R; Barbé, F; Pericás, J; Agusti, A G

    2000-04-01

    Daytime sleepiness, impaired cognitive performance and dysphoric mood are often present in patients with obstructive sleep apnoea syndrome (SAS). This prospective controlled study evaluates the effects of treatment with continuous positive airway pressure (CPAP) during 1 yr on daytime functioning in a large group of patients with SAS. The authors studied 80 patients (mean+/-sem 49+/-1 yrs) with SAS with a mean apnoea-hypopnoea index of 60+/-2 h-1, and 80 healthy control subjects matched for sex and age (46+/-1 yrs.). Measurements were obtained at the beginning of the study and 12+/-1 months later, and included: daytime sleepiness (Epworth scale), depression and anxiety (Beck tests), vigilance (Steer-Clear) and reaction time (Psychometer Vigilance Test 192). Drug, coffee and alcohol intake, as well as the sleep schedule, were also recorded. Results showed that, before treatment, patients were more somnolent (p<0.001), anxious (p<0.01) and depressed (p<0.001) than control subjects. Also, they had a longer reaction time (p<0.05) and poorer vigilance (p<0.01). The use of CPAP improved significantly the levels of somnolence (p<0.0001) and vigilance (p<0.01), but failed to modify anxiety and depression. Reaction time changes were minor. Variables with a potential confounding effect did not change during the study. These results provide firm evidence to substantiate the use of continuous positive airway pressure in patients with sleep apnoea syndrome. PMID:10780758

  12. Vascular tracers alter hemodynamics and airway pressure in anesthetized sheep

    SciTech Connect

    Albertine, K.H.; Staub, N.C.

    1986-11-01

    The technique of vascular labeling was developed to mark sites of increased microvascular permeability. We used the vascular labeling technique in anesthetized sheep and found that hemodynamics and airway pressure were adversely affected by intraarterial infusions of two vascular tracers. Monastral blue (nine sheep) immediately caused systemic arterial hypotension, pulmonary arterial hypertension, and bronchoconstriction. All three physiological responses were partially blocked by a cyclooxygenase inhibitor (indomethacin) but not by an H1-antihistamine (chlorpheniramine). Colloidal gold (nine sheep) caused immediate, but less dramatic, pulmonary arterial hypertension which was not attenuated by the blocking agents. We conclude that these two vascular tracers caused detrimental physiological side effects in sheep at the usual doses used to label injured microvessels in other species.

  13. Fiberoptic nasopharyngoscopy for evaluating a potentially difficult airway in a patient with elevated intracranial pressure.

    PubMed

    Kurnutala, Lakshmi N; Sandhu, Gurneet; Bergese, Sergio D

    2016-11-01

    A 62-year-old man with a left temporal lobe tumor was scheduled for a semiurgent craniotomy for tumor excision. Previously, the patient had a laryngeal carcinoma that was resected and treated with chemotherapy and radiotherapy and a history of laryngeal biopsy with awake fiberoptic intubation. Because a difficult airway was anticipated, awake fiberoptic nasopharyngoscopy of the airway was performed under topical anesthesia in the operating room. This revealed a narrow glottic opening with no supraglottic pathology or friable tissue. Based on these airway observations, we proceeded safely with intravenous induction and secured the airway in a controlled fashion, thereby minimizing the risk of increased intracranial pressure and catastrophic complications. Nasopharyngoscopy can be used safely to evaluate the upper airway to stratify airway management in patients with a history of head and neck cancer presenting for neurosurgical procedures in the setting of elevated intracranial pressure. PMID:27687404

  14. Brain stem activity changes associated with restored sympathetic drive following CPAP treatment in OSA subjects: a longitudinal investigation.

    PubMed

    Lundblad, Linda C; Fatouleh, Rania H; McKenzie, David K; Macefield, Vaughan G; Henderson, Luke A

    2015-08-01

    Obstructive sleep apnea (OSA) is associated with significantly elevated muscle sympathetic nerve activity (MSNA), leading to hypertension and increased cardiovascular morbidity. Although little is known about the mechanisms responsible for the sympathoexcitation, we have recently shown that the elevated MSNA in OSA is associated with altered neural processing in various brain stem sites, including the dorsolateral pons, rostral ventrolateral medulla, medullary raphe, and midbrain. Given the risk associated with elevated MSNA, we aimed to determine if treatment of OSA with continuous positive airway pressure (CPAP) would reduce the elevated MSNA and reverse the brain stem functional changes associated with the elevated MSNA. We performed concurrent recordings of MSNA and blood oxygen level-dependent (BOLD) signal intensity of the brain stem, using high-resolution functional magnetic resonance imaging, in 15 controls and 13 subjects with OSA, before and after 6 mo CPAP treatment. As expected, 6 mo of CPAP treatment significantly reduced MSNA in subjects with OSA, from 54 ± 4 to 23 ± 3 bursts/min and from 77 ± 7 to 36 ± 3 bursts/100 heart beats. Importantly, we found that MSNA-coupled changes in BOLD signal intensity within the dorsolateral pons, medullary raphe, and rostral ventrolateral medulla returned to control levels. That is, CPAP treatment completely reversed brain stem functional changes associated with elevated MSNA in untreated OSA subjects. These data highlight the effectiveness of CPAP treatment in reducing one of the most significant health issues associated with OSA, that is, elevated MSNA and its associated elevated morbidity. PMID:25995345

  15. Brain stem activity changes associated with restored sympathetic drive following CPAP treatment in OSA subjects: a longitudinal investigation

    PubMed Central

    Lundblad, Linda C.; Fatouleh, Rania H.; McKenzie, David K.; Macefield, Vaughan G.

    2015-01-01

    Obstructive sleep apnea (OSA) is associated with significantly elevated muscle sympathetic nerve activity (MSNA), leading to hypertension and increased cardiovascular morbidity. Although little is known about the mechanisms responsible for the sympathoexcitation, we have recently shown that the elevated MSNA in OSA is associated with altered neural processing in various brain stem sites, including the dorsolateral pons, rostral ventrolateral medulla, medullary raphe, and midbrain. Given the risk associated with elevated MSNA, we aimed to determine if treatment of OSA with continuous positive airway pressure (CPAP) would reduce the elevated MSNA and reverse the brain stem functional changes associated with the elevated MSNA. We performed concurrent recordings of MSNA and blood oxygen level-dependent (BOLD) signal intensity of the brain stem, using high-resolution functional magnetic resonance imaging, in 15 controls and 13 subjects with OSA, before and after 6 mo CPAP treatment. As expected, 6 mo of CPAP treatment significantly reduced MSNA in subjects with OSA, from 54 ± 4 to 23 ± 3 bursts/min and from 77 ± 7 to 36 ± 3 bursts/100 heart beats. Importantly, we found that MSNA-coupled changes in BOLD signal intensity within the dorsolateral pons, medullary raphe, and rostral ventrolateral medulla returned to control levels. That is, CPAP treatment completely reversed brain stem functional changes associated with elevated MSNA in untreated OSA subjects. These data highlight the effectiveness of CPAP treatment in reducing one of the most significant health issues associated with OSA, that is, elevated MSNA and its associated elevated morbidity. PMID:25995345

  16. Reversal of functional changes in the brain associated with obstructive sleep apnoea following 6 months of CPAP.

    PubMed

    Fatouleh, Rania H; Lundblad, Linda C; Macey, Paul M; McKenzie, David K; Henderson, Luke A; Macefield, Vaughan G

    2015-01-01

    Obstructive sleep apnoea (OSA) is associated with an increase in the number of bursts of muscle sympathetic nerve activity (MSNA), leading to neurogenic hypertension. Continuous positive airway pressure (CPAP) is the most effective and widely used treatment for preventing collapse of the upper airway in OSA. In addition to improving sleep, CPAP decreases daytime MSNA towards control levels. It remains unknown how this restoration of MSNA occurs, in particular whether CPAP treatment results in a simple readjustment in activity of those brain regions responsible for the initial increase in MSNA or whether other brain regions are recruited to over-ride aberrant brain activity. By recording MSNA concurrently with functional Magnetic Resonance Imaging (fMRI), we aimed to assess brain activity associated with each individual subject's patterns of MSNA prior to and following 6 months of CPAP treatment. Spontaneous fluctuations in MSNA were recorded via tungsten microelectrodes inserted into the common peroneal nerve in 13 newly diagnosed patients with OSA before and after 6 months of treatment with CPAP and in 15 healthy control subjects while lying in a 3 T MRI scanner. Blood Oxygen Level Dependent (BOLD) contrast gradient echo, echo-planar images were continuously collected in a 4 s ON, 4 s OFF (200 volumes) sampling protocol. MSNA was significantly elevated in newly diagnosed OSA patients compared to control subjects (55 ± 4 vs 26 ± 2 bursts/min). Fluctuations in BOLD signal intensity in multiple regions covaried with the intensity of the concurrently recorded bursts of MSNA. There was a significant fall in MSNA after 6 months of CPAP (39 ± 2 bursts/min). The reduction in resting MSNA was coupled with significant falls in signal intensity in precuneus bilaterally, the left and right insula, right medial prefrontal cortex, right anterior cingulate cortex, right parahippocampus and the left and right retrosplenial cortices. These data support our contention that

  17. Reversal of functional changes in the brain associated with obstructive sleep apnoea following 6 months of CPAP.

    PubMed

    Fatouleh, Rania H; Lundblad, Linda C; Macey, Paul M; McKenzie, David K; Henderson, Luke A; Macefield, Vaughan G

    2015-01-01

    Obstructive sleep apnoea (OSA) is associated with an increase in the number of bursts of muscle sympathetic nerve activity (MSNA), leading to neurogenic hypertension. Continuous positive airway pressure (CPAP) is the most effective and widely used treatment for preventing collapse of the upper airway in OSA. In addition to improving sleep, CPAP decreases daytime MSNA towards control levels. It remains unknown how this restoration of MSNA occurs, in particular whether CPAP treatment results in a simple readjustment in activity of those brain regions responsible for the initial increase in MSNA or whether other brain regions are recruited to over-ride aberrant brain activity. By recording MSNA concurrently with functional Magnetic Resonance Imaging (fMRI), we aimed to assess brain activity associated with each individual subject's patterns of MSNA prior to and following 6 months of CPAP treatment. Spontaneous fluctuations in MSNA were recorded via tungsten microelectrodes inserted into the common peroneal nerve in 13 newly diagnosed patients with OSA before and after 6 months of treatment with CPAP and in 15 healthy control subjects while lying in a 3 T MRI scanner. Blood Oxygen Level Dependent (BOLD) contrast gradient echo, echo-planar images were continuously collected in a 4 s ON, 4 s OFF (200 volumes) sampling protocol. MSNA was significantly elevated in newly diagnosed OSA patients compared to control subjects (55 ± 4 vs 26 ± 2 bursts/min). Fluctuations in BOLD signal intensity in multiple regions covaried with the intensity of the concurrently recorded bursts of MSNA. There was a significant fall in MSNA after 6 months of CPAP (39 ± 2 bursts/min). The reduction in resting MSNA was coupled with significant falls in signal intensity in precuneus bilaterally, the left and right insula, right medial prefrontal cortex, right anterior cingulate cortex, right parahippocampus and the left and right retrosplenial cortices. These data support our contention that

  18. Reversal of functional changes in the brain associated with obstructive sleep apnoea following 6 months of CPAP

    PubMed Central

    Fatouleh, Rania H.; Lundblad, Linda C.; Macey, Paul M.; McKenzie, David K.; Henderson, Luke A.; Macefield, Vaughan G.

    2015-01-01

    Obstructive sleep apnoea (OSA) is associated with an increase in the number of bursts of muscle sympathetic nerve activity (MSNA), leading to neurogenic hypertension. Continuous positive airway pressure (CPAP) is the most effective and widely used treatment for preventing collapse of the upper airway in OSA. In addition to improving sleep, CPAP decreases daytime MSNA towards control levels. It remains unknown how this restoration of MSNA occurs, in particular whether CPAP treatment results in a simple readjustment in activity of those brain regions responsible for the initial increase in MSNA or whether other brain regions are recruited to over-ride aberrant brain activity. By recording MSNA concurrently with functional Magnetic Resonance Imaging (fMRI), we aimed to assess brain activity associated with each individual subject's patterns of MSNA prior to and following 6 months of CPAP treatment. Spontaneous fluctuations in MSNA were recorded via tungsten microelectrodes inserted into the common peroneal nerve in 13 newly diagnosed patients with OSA before and after 6 months of treatment with CPAP and in 15 healthy control subjects while lying in a 3 T MRI scanner. Blood Oxygen Level Dependent (BOLD) contrast gradient echo, echo-planar images were continuously collected in a 4 s ON, 4 s OFF (200 volumes) sampling protocol. MSNA was significantly elevated in newly diagnosed OSA patients compared to control subjects (55 ± 4 vs 26 ± 2 bursts/min). Fluctuations in BOLD signal intensity in multiple regions covaried with the intensity of the concurrently recorded bursts of MSNA. There was a significant fall in MSNA after 6 months of CPAP (39 ± 2 bursts/min). The reduction in resting MSNA was coupled with significant falls in signal intensity in precuneus bilaterally, the left and right insula, right medial prefrontal cortex, right anterior cingulate cortex, right parahippocampus and the left and right retrosplenial cortices. These data support our

  19. Submental negative pressure application decreases collapsibility of the passive pharyngeal airway in nonobese women.

    PubMed

    Kato, Shinichiro; Isono, Shiroh; Amemiya, Megumi; Sato, Shin; Ikeda, Aya; Okazaki, Junko; Sato, Yumi; Ishikawa, Teruhiko

    2015-04-01

    The pharyngeal airway is surrounded by soft tissues that are also enclosed by bony structures such as the mandible, maxilla, and cervical spine. The passive pharyngeal airway is therefore structurally analogous to a collapsible tube within a rigid box. Cross-sectional area of the tube is determined by transmural pressure, the pressure difference between intraluminal and extraluminal pressures. Due to a lack of knowledge on the influence of extraluminal soft tissue pressure on the human pharyngeal airway patency, we hypothesized that application of negative external pressure to the submental region decreases collapsibility of the passive pharynx, and that obese individuals have less response to the intervention than nonobese individuals. Static mechanical properties of the passive pharynx were compared before and during application of submental negative pressure in 10 obese and 10 nonobese adult women under general anesthesia and paralysis. Negative pressure was applied through use of a silicone collar covering the entire submental region and a vacuum pump. In nonobese subjects, application of submental negative pressure (-25 and -50 cmH2O) significantly decreased closing pressures at the retropalatal airway by 2.3 ± 3.2 cmH2O and 2.0 ± 3.0 cmH2O, respectively, and at the retroglossal airway by 2.9 ± 2.7 cmH2O and 3.7 ± 2.6 cmH2O, respectively, and the intervention stiffened the retroglossal pharyngeal airway wall. No significant mechanical changes were observed during application of submental negative pressure in obese subjects. Conclusively, application of submental negative pressure was found to decreases collapsibility of the passive pharyngeal airway in nonobese Japanese women. PMID:25614595

  20. Severe upper airway obstruction during sleep.

    PubMed

    Bonekat, H William; Hardin, Kimberly A

    2003-10-01

    Few disorders may manifest with predominantly sleep-related obstructive breathing. Obstructive sleep apnea (OSA) is a common disorder, varies in severity and is associated with significant cardiovascular and neurocognitive morbidity. It is estimated that between 8 and 18 million people in the United States have at least mild OSA. Although the exact mechanism of OSA is not well-delineated, multiple factors contribute to the development of upper airway obstruction and include anatomic, mechanical, neurologic, and inflammatory changes in the pharynx. OSA may occur concomitantly with asthma. Approximately 74% of asthmatics experience nocturnal symptoms of airflow obstruction secondary to reactive airways disease. Similar cytokine, chemokine, and histologic changes are seen in both disorders. Sleep deprivation, chronic upper airway edema, and inflammation associated with OSA may further exacerbate nocturnal asthma symptoms. Allergic rhinitis may contribute to both OSA and asthma. Continuous positive airway pressure (CPAP) is the gold standard treatment for OSA. Treatment with CPAP therapy has also been shown to improve both daytime and nighttime peak expiratory flow rates in patients with concomitant OSA and asthma. It is important for allergists to be aware of how OSA may complicate diagnosis and treatment of asthma and allergic rhinitis. A thorough sleep history and high clinical suspicion for OSA is indicated, particularly in asthma patients who are refractory to standard medication treatments.

  1. Use of CPAP to reduce arterial stiffness in moderate-to-severe obstructive sleep apnoea, without excessive daytime sleepiness (STIFFSLEEP): an observational cohort study protocol

    PubMed Central

    Mineiro, Maria Alexandra; Marques da Silva, Pedro; Alves, Marta; Virella, Daniel; Marques Gomes, Maria João; Cardoso, João

    2016-01-01

    Introduction Sleepiness is a cardinal symptom in obstructive sleep apnoea (OSA) but most patients have unspecific symptoms. Arterial stiffness, evaluated by pulse wave velocity (PWV), is related to atherosclerosis and cardiovascular (CV) risk. Arterial stiffness was reported to be higher in patients with OSA, improving after treatment with continuous positive airway pressure (CPAP). This study aims to assess whether the same effect occurs in patients with OSA and without sleepiness. Methods and analysis This observational study assesses the CV effect of CPAP therapy on a cohort of patients with moderate-to-severe OSA; the effect on the subcohorts of sleepy and non-sleepy patients will be compared. A systematic and consecutive sample of patients advised CPAP therapy will be recruited from a single outpatient sleep clinic (Centro Hospitalar de Lisboa Central—CHLC, Portugal). Eligible patients are male, younger than 65 years, with confirmed moderate-to-severe OSA and apnoea–hypopnea index (AHI) above 15/hour. Other sleep disorders, diabetes or any CV disease other than hypertension are exclusion criteria. Clinical evaluation at baseline includes Epworth Sleepiness Scale (ESS), and sleepiness is defined as ESS above 10. OSA will be confirmed by polygraphic study (cardiorespiratory, level 3). Participants are advised to undertake an assessment of carotid-femoral PWV (cf-PWV) and 24 hours evaluation of ambulatory blood pressure monitoring (ABPM), at baseline and after 4 months of CPAP therapy. Compliance and effectiveness of CPAP will be assessed. The main outcome is the variation of cf-PWV over time. Ethics and dissemination This protocol was approved by the Ethics Committees of CHLC (reference number 84/2012) and NOVA Medical School (number36/2014/CEFCM), Lisbon. Informed, written consent will be obtained. Its results will be presented at conferences and published in peer-reviewed journals. Trial registration number NCT02273089; Pre-results. PMID:27406645

  2. Continuous positive airway pressure with pressure support ventilation is effective in treating acute-onset bilateral recurrent laryngeal nerve palsy.

    PubMed

    Leung, Yiuka; Fikry, Karim; Shah, Bhavika; Madapu, Manokanth; Gaz, Randall D; Leffert, Lisa R; Jiang, Yandong

    2015-06-01

    Acute bilateral recurrent laryngeal nerve injury leading to acute vocal cord paralysis (VCP) is a serious complication of head and neck surgery, often requiring emergent surgical intervention. Although well documented, its presentation may be sudden and unexpected, occurring despite lack of obvious intraoperative nerve injury. There is limited literature on airway management strategies for patients with acute bilateral VCP before attaining a secure airway. We report a case of acute VCP that was successfully treated with continuous positive airway pressure via facemask ventilation. This effective temporizing strategy allowed clinicians to plan and prepare for tracheostomy, minimizing potential complications.

  3. Effects of Positive Airway Pressure on Patients with Obstructive Sleep Apnea during Acute Ascent to Altitude

    PubMed Central

    Nishida, Katsufumi; Cloward, Tom V.; Weaver, Lindell K.; Brown, Samuel M.; Bell, James E.; Grissom, Colin K.

    2015-01-01

    Rationale: In acute ascent to altitude, untreated obstructive sleep apnea (OSA) is often replaced with central sleep apnea (CSA). In patients with obstructive sleep apnea who travel to altitude, it is unknown whether their home positive airway pressure (PAP) settings are sufficient to treat their obstructive sleep apnea, or altitude-associated central sleep apnea. Methods: Ten participants with positive airway pressure–treated obstructive sleep apnea, who reside at 1,320 m altitude, underwent polysomnography on their home positive airway pressure settings at 1,320 m and at a simulated altitude of 2,750 m in a hypobaric chamber. Six of the participants were subsequently studied without positive airway pressure at 2,750 m. Measurements and Main Results: At 1,320 m, all participants’ sleep apnea was controlled with positive airway pressure on home settings; at 2,750, no participants’ sleep apnea was controlled. At higher altitude, the apnea–hypopnea index was higher (11 vs. 2 events/h; P < 0.01), mostly due to hypopneas (10.5 vs. 2 events/h; P < 0.01). Mean oxygen saturations were lower (88 vs. 93%; P < 0.01) and total sleep time was diminished (349 vs. 393 min; P = 0.03). Four of six participants without positive airway pressure at 2,750 m required supplemental oxygen to prevent sustained oxygen saturation (as determined by pulse oximetry) less than 80%. Positive airway pressure also was associated with reduced central sleep apnea (0 vs. 1; P = 0.03), improved sleep time (358 vs. 292 min; P = 0.06), and improved sleep efficiency (78 vs. 63%; P = 0.04). Conclusions: Acute altitude exposure in patients with obstructive sleep apnea treated with positive airway pressure is associated with hypoxemia, decreased sleep time, and increased frequency of hypopneas compared with baseline altitude. Application of positive airway pressure at altitude is associated with decreased central sleep apnea and increased sleep efficiency. PMID:25884271

  4. Upper Airway Collapsibility (Pcrit) and Pharyngeal Dilator Muscle Activity are Sleep Stage Dependent

    PubMed Central

    Carberry, Jayne C.; Jordan, Amy S.; White, David P.; Wellman, Andrew; Eckert, Danny J.

    2016-01-01

    Study Objectives: An anatomically narrow/highly collapsible upper airway is the main cause of obstructive sleep apnea (OSA). Upper airway muscle activity contributes to airway patency and, like apnea severity, can be sleep stage dependent. Conversely, existing data derived from a small number of participants suggest that upper airway collapsibility, measured by the passive pharyngeal critical closing pressure (Pcrit) technique, is not sleep stage dependent. This study aimed to determine the effect of sleep stage on Pcrit and upper airway muscle activity in a larger cohort than previously tested. Methods: Pcrit and/or muscle data were obtained from 72 adults aged 20–64 y with and without OSA.Pcrit was determined via transient reductions in continuous positive airway pressure (CPAP) during N2, slow wave sleep (SWS) and rapid eye movement (REM) sleep. Genioglossus and tensor palatini muscle activities were measured: (1) awake with and without CPAP, (2) during stable sleep on CPAP, and (3) in response to the CPAP reductions used to quantify Pcrit. Results: Pcrit was 4.9 ± 1.4 cmH2O higher (more collapsible) during REM versus SWS (P = 0.012), 2.3 ± 0.6 cmH2O higher during REM versus N2 (P < 0.001), and 1.6 ± 0.7 cmH2O higher in N2 versus SWS (P = 0.048). Muscle activity decreased from wakefulness to sleep and from SWS to N2 to REM sleep for genioglossus but not for tensor palatini. Pharyngeal muscle activity increased by ∼50% by breath 5 following CPAP reductions. Conclusions: Upper airway collapsibility measured via the Pcrit technique and genioglossus muscle activity vary with sleep stage. These findings should be taken into account when performing and interpreting “passive” Pcrit measurements. Citation: Carberry JC, Jordan AS, White DP, Wellman A, Eckert DJ. Upper airway collapsibility (Pcrit) and pharyngeal dilator muscle activity are sleep stage dependent. SLEEP 2016;39(3):511–521. PMID:26612386

  5. Evaluation of an auto-CPAP device for treatment of obstructive sleep apnoea

    PubMed Central

    Ficker, J; Wiest, G; Lehnert, G; Wiest, B; Hahn, E

    1998-01-01

    BACKGROUND—Auto-CPAP machines used in the treatment of obstructive sleep apnoea (OSA) are designed to vary the treatment pressure automatically in order always to apply the actually needed pressure. Consequently they should be able to achieve at least identical therapeutic effects as conventional constant pressure CPAP with a lower mean treatment pressure. The present study was designed to evaluate the therapeutic efficacy and the treatment pressure of an auto-CPAP machine (REM+auto®, SEFAM) in comparison with a conventional CPAP device.
METHODS—Following CPAP titration, 16 patients with OSA were allocated to receive conventional CPAP and auto-CPAP treatment under polysomnographic control in a randomised order. After each treatment the patients were asked to assess the therapy using a questionnaire; a vigilance test was also carried out and subjective daytime sleepiness was evaluated using the Epworth Sleepiness Scale (ESS).
RESULTS—The mean (SD) apnoea/hypopnoea index (AHI) during auto-CPAP treatment was comparable with that during conventional CPAP treatment (4.2 (5.1) versus 3.6 (4.0)). Neither an analysis of sleep architecture nor the arousal index (7.4 (4.1) versus 7.0 (4.3)) revealed any significant differences. Daytime sleepiness measured with the ESS was also comparable (5.3 (3.4) versus 6.5 (4.2)). The vigilance test showed normal values after both treatments in all patients with no significant differences. The mean pressure during auto-CPAP treatment (8.1 (2.9) mbar), however, was significantly higher than that employed in conventional CPAP treatment (7.6 (2.7) mbar; mean difference 0.5 mbar; 95% CI 0.1 to 0.9 mbar; p<0.05).
CONCLUSIONS—Auto-CPAP was equally as effective as conventional CPAP with respect to therapeutic efficacy. The aim of reducing the treatment pressure with auto-CPAP, however, was not achieved.

 PMID:9828849

  6. CPAP Adherence in Patients with Newly Diagnosed Obstructive Sleep Apnea prior to Elective Surgery

    PubMed Central

    Guralnick, Amy S.; Pant, Melissa; Minhaj, Mohammed; Sweitzer, Bobbie Jean; Mokhlesi, Babak

    2012-01-01

    Background: Obstructive sleep apnea (OSA) is prevalent in the surgical population, and it has been suggested that preoperative patients should be screened and treated for OSA. However, it remains unclear whether patients diagnosed with OSA in the preoperative period adhere to prescribed CPAP therapy. Objective: Our aim was to objectively quantify CPAP adherence, investigate predictors of poor CPAP adherence, and to establish an optimal CPAP setting in a cohort of presurgical patients diagnosed with OSA as part of the preoperative work-up. Methods: In a retrospective observational study, we collected data on all adult presurgical patients seen by the Anesthesia Perioperative Medicine Clinic (APMC) who screened positive for OSA on the STOP-Bang questionnaire and underwent an in-laboratory diagnostic polysomnogram (PSG) before surgery. CPAP was offered to patients with moderate or severe OSA. Objective CPAP adherence was recorded during the perioperative period. Factors associated with reduced CPAP adherence were delineated. Patient characteristics were compared between those with STOP-Bang scores of 3-4 and those with higher scores (STOP-Bang score ≥ 5). Results: During a 2-year period, 431 patients were referred and 211 patients completed a PSG. CPAP therapy was required in 65% of patients, and the optimal level was 9 ± 2 cm H2O. Objective CPAP adherence was available in 75% of patients who received CPAP therapy; median adherence was 2.5 h per night, without any significant difference between the STOP-Bang subgroups. African American race, male gender, and depressive symptomatology were independent predictors of reduced CPAP adherence. Severe OSA was significantly more prevalent in patients with a STOP-Bang score ≥ 5 than those whose score was 3-4 (55.1% versus 34.4%, p = 0.005). However, optimum CPAP pressure levels and adherence to therapy did not differ between the 2 STOP-Bang groups. Conclusions: Adherence to prescribed CPAP therapy during the perioperative

  7. Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea.

    PubMed

    Nolan, G M; Ryan, S; O'connor, T M; McNicholas, W T

    2006-07-01

    Auto-adjustable continuous positive airway pressure (APAP) devices are an emerging treatment alternative to fixed-pressure continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome. They have been engineered to automatically adjust the pressure to the optimal level on a continuous basis. However, not all APAP technologies use the same algorithm. Three different APAP devices (Autoset Spirit, Breas PV 10i and RemStar Auto) were compared in a randomised crossover trial in patients already established on fixed-pressure CPAP therapy. The outcome measures were compliance, quality of life and side-effects. Twenty-seven middle-aged patients (25 male) previously diagnosed with severe obstructive sleep apnoea syndrome (median (interquartile range) apnoea/hypopnoea index 48 (29-76)), established on CPAP therapy for >3 yrs, were randomised to each APAP device for 4 weeks. Mean pressure and patient compliance were significantly lower on the Breas PV 10i than on the other APAP devices. The devices were similar in terms of quality of life, daytime sleepiness and upper airway side-effects, but patients evaluated them significantly differently in terms of device features, sleep quality and pressure comfort, with the Breas PV 10i being the least popular. Auto-adjustable positive airway pressure devices differ in pressure delivery and patient compliance in obstructive sleep apnoea syndrome patients. PMID:16571610

  8. [Postoperative sore throat and intracuff pressure: comparison among endotracheal intubation, laryngeal mask airway and cuffed oropharyngeal airway].

    PubMed

    Saeki, H; Morimoto, Y; Yamashita, A; Nagusa, Y; Shimizu, K; Oka, H; Miyauchi, Y

    1999-12-01

    We studied which device is most useful to reduce postoperative sore-throat. We investigated the relationship between intracuff pressure and postoperative sore-throat in using endotracheal intubation (ET), the laryngeal mask airway (LMA) and the cuffed oropharyngeal airway (COPA) in adult patients. We classified sore-throat into categories; pain at rest, hoarseness and dysphasia. We evaluated pain at rest by the score (0: no pain, 1: mild discomfort, 2: mild pain, 3: severe pain). Pain at rest (scores 1, 2, 3) was complained by 10 patients in ET group, 3 in LMA group, 5 in COPA group on the day of operation, showing significantly lower incidence of pain at rest in LMA group than in ET group. Hoarseness was complained by 15 patients in ET group, 2 in LMA group and 4 in COPA group, showing significantly lower incidence of hoarseness in LMA and COPA groups than in ET group. Dysphasia was complained by 3 in ET group, 1 in LMA group and 2 in COPA group, showing no significant difference. These results suggest that LMA is most appropriate to reduce postoperative sore-throat.

  9. Do Cognitive Perceptions Influence CPAP Use?

    PubMed Central

    Sawyer, Amy M.; Canamucio, Ann; Moriarty, Helene; Weaver, Terri E.; Richards, Kathy; Kuna, Samuel T.

    2010-01-01

    Objective Nonadherence to CPAP increases health and functional risks of obstructive sleep apnea. The study purpose was to examine if disease and treatment cognitive perceptions influence short-term CPAP use. Methods A prospective longitudinal study included 66, middle-aged (56.7 yr ± 10.7) subjects (34 [51.5%] Caucasians; 30 [45.4%] African Americans) with severe OSA (AHI 43.5 events/hr ± 24.6). Following full-night diagnostic/CPAP polysomnograms, home CPAP use was objectively measured at 1 week and 1 month. The Self Efficacy Measure for Sleep Apnea questionnaire (SEMSA), measuring risk perception, outcome expectancies, and self-efficacy, was collected at baseline, post-CPAP education, and after 1 week CPAP treatment. Regression models were used. Results CPAP use at one week was 3.99 hr/night ± 2.48 and 3.06 hr/night ± 2.43 at one month. No baseline SEMSA domains influenced CPAP use. Post-education self-efficacy influenced one week CPAP use (1.52±0.53, p=0.007). Self-efficacy measured post-education and after one week CPAP use also influenced one month CPAP (1.40±0.52, p=0.009; 1.20±0.50, p=0.02, respectively). Conclusion Cognitive perceptions influence CPAP use, but only within the context of knowledge of CPAP treatment and treatment use. Practice Implications Patient education is important to OSA patients' formulation of accurate and realistic disease and treatment perceptions which influence CPAP adherence. PMID:21071166

  10. Origins of and implementation concepts for upper airway stimulation therapy for obstructive sleep apnea.

    PubMed

    Strohl M D, Kingman P; Baskin M D, Jonathan; Lance M D, Colleen; Ponsky M D, Diana; Weidenbecher M D, Mark; Strohl B A, Madeleine; Yamauchi M D, Motoo

    2016-07-01

    Upper airway stimulation, specifically hypoglossal (CN XII) nerve stimulation, is a new, alternative therapy for patients with obstructive sleep apnea hypopnea syndrome who cannot tolerate positive airway pressure, the first-line therapy for symptomatic patients. Stimulation therapy addresses the cause of inadequate upper airway muscle activation for nasopharyngeal and oropharyngeal airway collapse during sleep. The purpose of this report is to outline the development of this first-in-class therapy and its clinical implementation. Another practical theme is assessment of the features for considering a surgically implanted device and the insight as to how both clinical and endoscopic criteria increase the likelihood of safe and durable outcomes for an implant and how to more generally plan for management of CPAP-intolerant patients. A third theme is the team building required among sleep medicine and surgical specialties in the provision of individualized neurostimulation therapy. PMID:27424823

  11. HW 03-2 EFFECT OF CPAP ON THE TREATMENT OF RESISTANT HYPERTENSION.

    PubMed

    Kim, Seong Hwan

    2016-09-01

    patients with resistant hypertension are being used, continuous positive airway pressure (CPAP) and life style modification in addition to antihypertensive medication are known to be very effective standard methods. Most of all, the effect of CPAP in patients with OSA and resistant hypertension has been demonstrated to have a significant benefit. Especially, better results with use of CPAP were observed in patients with severe OSA. Nevertheless, this standard is still challenging for some patients because of poor adherence, so new therapies including renal denervation and bariatric surgery are providing significant therapeutic benefits. In this talk, the effect of CAPA in patients with OSA and resistant hypertension will be discussed. PMID:27643276

  12. Effects of CPAP-therapy on brain electrical activity in obstructive sleep apneic patients: a combined EEG study using LORETA and Omega complexity : reversible alterations of brain activity in OSAS.

    PubMed

    Toth, Marton; Faludi, Bela; Kondakor, Istvan

    2012-10-01

    Effects of initiation of continuous positive airway pressure (CPAP) therapy on EEG background activity were investigated in patients with obstructive sleep apnea syndrome (OSAS, N = 25) to test possible reversibility of alterations of brain electrical activity caused by chronic hypoxia. Normal control group (N = 14) was also examined. Two EEG examinations were done in each groups: at night and in the next morning. Global and regional (left vs. right, anterior vs. posterior) measures of spatial complexity (Omega complexity) were used to characterize the degree of spatial synchrony of EEG. Low resolution electromagnetic tomography (LORETA) was used to localize generators of EEG activity in separate frequency bands. Before CPAP-treatment, a significantly lower Omega complexity was found globally and over the right hemisphere. Due to CPAP-treatment, these significant differences vanished. Significantly decreased Omega complexity was found in the anterior region after treatment. LORETA showed a decreased activity in all of the beta bands after therapy in the right hippocampus, premotor and temporo-parietal cortex, and bilaterally in the precuneus, paracentral and posterior cingulate cortex. No significant changes were seen in control group. Comparing controls and patients before sleep, an increased alpha2 band activity was seen bilaterally in the precuneus, paracentral and posterior cingulate cortex, while in the morning an increased beta3 band activity in the left precentral and bilateral premotor cortex and a decreased delta band activity in the right temporo-parietal cortex and insula were observed. These findings indicate that effect of sleep on EEG background activity is different in OSAS patients and normal controls. In OSAS patients, significant changes lead to a more normal EEG after a night under CPAP-treatment. Compensatory alterations of brain electrical activity in regions associated with influencing sympathetic outflow, visuospatial abilities, long

  13. Negative Expiratory Pressure Technique: An Awake Test to Measure Upper Airway Collapsibility in Adolescents

    PubMed Central

    Carrera, Helena Larramona; Marcus, Carole L.; McDonough, Joseph M.; Morera, Joan C. Oliva; Huang, Jingtao; Farre, Ramon; Montserrat, Josep M.

    2015-01-01

    Study Objectives: Upper airway (UA) collapsibility is a major pathophysiologic feature of the obstructive sleep apnea syndrome (OSAS). In adolescents, it is measured by obtaining the slope of pressure-flow relationship (SPF) while applying negative nasal pressure during sleep. An easier technique to assess UA collapsibility, consisting of application of negative expiratory pressure (NEP) during wakefulness, has demonstrated differences between control and OSAS subjects. We hypothesized that the NEP technique would correlate with SPF as a measurement of UA collapsibility in adolescents. Design: During wakefulness, NEP of −5 cm H2O in the seated and supine position was applied during the first second of expiration. The area under the expiratory flow-volume curve during NEP was compared to tidal breathing (RatioNEP). In addition, adolescents underwent SPF measurements during sleep. Two SPF techniques were performed to measure the activated and relatively hypotonic UA. Setting: Pediatric sleep laboratory. Participants: Seven adolescents with OSAS and 20 controls. Results: In the seated position, there was a correlation between RatioNEP and both hypotonic SPF (r = −0.39, P = 0.04) and activated SPF (r = −0.62, P = 0.001). In the supine position, there was a correlation between RatioNEP and activated SPF (r = −0.43, P = 0.03) and a trend for hypotonic SPF (r = −0.38, P = 0.06). Conclusions: The negative expiratory pressure (NEP) technique correlates with the hypotonic and activated slope of pressure-flow relationship measurements. The seated position showed the strongest correlation. The NEP technique can be used as an alternative method to evaluate upper airway collapsibility in adolescents. Citation: Carrera HL, Marcus CL, McDonough JM, Morera JC, Huang J, Farre R, Montserrat JM. Negative expiratory pressure technique: an awake test to measure upper airway collapsibility in adolescents. SLEEP 2015;38(11):1783–1791. PMID:26158888

  14. Use of Biphasic Continuous Positive Airway Pressure in Premature Infant with Cleft Lip–Cleft Palate

    PubMed Central

    George, Lovya; Jain, Sunil K.

    2015-01-01

    Preterm infants (PIs) often require respiratory support due to surfactant deficiency. Early weaning from mechanical ventilation to noninvasive respiratory support decreases ventilation-associated irreversible lung damage. This wean is particularly challenging in PIs with cleft lip and cleft palate due to anatomical difficulties encountered in maintaining an adequate seal for positive pressure ventilation. PI with a cleft lip and palate often fail noninvasive respiratory support and require continued intubation and mechanical ventilation. We are presenting the first case report of a PI with cleft lip and palate who was managed by biphasic nasal continuous positive airway pressure. PMID:26495158

  15. Early Surfactant Therapy With Nasal Continuous Positive Airway Pressure or Continued Mechanical Ventilation in Very Low Birth Weight Neonates With Respiratory Distress Syndrome

    PubMed Central

    Najafian, Bita; Fakhraie, Seyed Hasan; Afjeh, Seyed Abulfazl; Kazemian, Mohammad; Shohrati, Majid; Saburi, Amin

    2014-01-01

    Background: Various strategies have been suggested for the treatment of respiratory distress syndrome (RDS). Objectives: The aim of this study was to compare the efficacies of two common methods of RDS management among neonates with low birth weight. Patients and Methods: A cohort study was conducted on 98 neonates with definite diagnosis of RDS during 2008-2009. The neonates were divided into two groups by a blinded supervisor using simple randomization (odd and even numbers). Forty-five cases in the first group were treated with intubation, surfactant therapy, extubation (INSURE method) followed by nasal continuous positive airway pressure (N.CPAP) and 53 cases in the second group underwent intubation, surfactant therapy followed by mechanical ventilation (MV). Results: Five (11.1%) cases in the first group and 23 (43%) cases in the second group expired during the study. The rates of MV dependency among cases with INSURE failure and cases in the MV group were 37% and 83%, respectively (P < 0.001). Birth weight (BW) (P = 0.017), presence of retinopathy of prematurity (P = 0.022), C/S delivery (P = 0.029) and presence of lung bleeding (P = 0.010) could significantly predict mortality in the second group, although only BW (P = 0.029) had a significant impact on the mortality rate in the first group. Moreover, BW was significantly related to the success rate in the first group (P = 0.001). Conclusions: Our findings demonstrated that INSURE plus NCPAP was more effective than the routine method (permanent intubation after surfactant prescription). In addition, the lower rates of mortality, MV dependency, duration of hospitalization, and complications were observed in cases treated with the INSURE method compared to the routine one. PMID:24910785

  16. Polysomnographic parameters during non-rapid eye movement sleep predict continuous positive airway pressure adherence.

    PubMed

    Hoshino, Tetsurou; Sasanabe, Ryujiro; Murotani, Kenta; Arimoto, Mariko; Inagawa, Shuntaro; Tanigawa, Tohru; Uchida, Yasue; Ogawa, Tetsuya; Ueda, Hiromi; Shiomi, Toshiaki

    2016-05-01

    The aim of this study was to investigate the potential polysomnographic predictors of CPAP adherence using polysomnographic parameters at the time of obstructive sleep apnea diagnosis that distinguished between REM and NREM sleep. This was a retrospective cross-sectional study of 173 patients. Patients who used CPAP for more than 4 hours per night for at least 70% of nights over a 6-month period were considered to have good adherence. The poor adherence group included those who had used CPAP for 6 months from initiation, but did not fulfill the definition of good adherence or gave up the treatment within 6 months of treatment initiation. Of the 173 participants, 44 patients had good CPAP adherence and 129 patients had poor adherence. Univariate analysis showed that patients with good adherence had significantly higher apnea-hypopnea index during NREM sleep (p = 0.043), oxygen desaturation index during NREM sleep (p = 0.011), and cumulative percentage of time spent at saturations below 90% (CT90) during NREM sleep (p < .001). In multiple logistic regression analysis including all variables, CT90 during NREM sleep was the only factor independently associated with CPAP adherence (odds ratio, 0.693; 95% confidence interval, 0.582-0.824; p <.0001). The area under the receiver-operating characteristic curve of CT90 during NREM sleep was 0.823 (95% confidence interval, 0.745-0.901).Evaluating NREM sleep is important in reliably predicting CPAP adherence using polysomnographic parameters. CT90 during NREM sleep was the best predictor of CPAP adherence. PMID:27303106

  17. Impact of CPAP on Activity Patterns and Diet in Patients with Obstructive Sleep Apnea (OSA)

    PubMed Central

    Batool-Anwar, Salma; Goodwin, James L.; Drescher, Amy A.; Baldwin, Carol M.; Simon, Richard D.; Smith, Terry W.; Quan, Stuart F.

    2014-01-01

    Study Objectives: Patients with severe OSA consume greater amounts of cholesterol, protein, and fat as well as have greater caloric expenditure. However, it is not known whether their activity levels or diet change after treatment with CPAP. To investigate this issue, serial assessments of activity and dietary intake were performed in the Apnea Positive Pressure Long-term Efficacy Study (APPLES); a 6-month randomized controlled study of CPAP vs. sham CPAP on neurocognitive outcomes. Methods: Subjects were recruited into APPLES at 5 sites through clinic encounters or public advertisement. After undergoing a diagnostic polysomnogram, subjects were randomized to CPAP or sham if their AHI was ≥ 10. Adherence was assessed using data cards from the devices. At the Tucson and Walla Walla sites, subjects were asked to complete validated activity and food frequency questionnaires at baseline and their 4-month visit. Results: Activity and diet data were available at baseline and after 4 months treatment with CPAP or sham in up to 231 subjects (117 CPAP, 114 Sham). Mean age, AHI, BMI, and Epworth Sleepiness Score (ESS) for this cohort were 55 ± 13 [SD] years, 44 ± 27 /h, 33 ± 7.8 kg/m2, and 10 ± 4, respectively. The participants lacking activity and diet data were younger, had lower AHI and arousal index, and had better sleep efficiency (p < 0.05). The BMI was higher among women in both CPAP and Sham groups. However, compared to women, men had higher AHI only in the CPAP group (50 vs. 34). Similarly, the arousal index was higher among men in CPAP group. Level of adherence defined as hours of device usage per night at 4 months was significantly higher among men in CPAP group (4.0 ± 2.9 vs. 2.6 ± 2.6). No changes in consumption of total calories, protein, carbohydrate or fat were noted after 4 months. Except for a modest increase in recreational activity in women (268 ± 85 vs. 170 ± 47 calories, p < 0.05), there also were no changes in activity patterns. Conclusion

  18. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    PubMed Central

    Moro, Marilyn; Gannon, Karen; Lovell, Kathy; Merlino, Margaret; Mojica, James; Bianchi, Matt T

    2016-01-01

    Purpose Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management. Methods We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split-night; n=306 two-night). Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG) data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI) ≥5 during split-night PSG (SN-PSG) versus full-night PSG (FN-PSG) titrations. Results CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients. Conclusion Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the laboratory setting, even as PSG remains the gold standard for characterizing primary central apnea and TECSA. PMID:27555802

  19. Bubble continuous positive airway pressure in a human immunodeficiency virus-infected infant

    PubMed Central

    McCollum, E. D.; Smith, A.; Golitko, C. L.

    2014-01-01

    SUMMARY World Health Organization-classified very severe pneumonia due to Pneumocystis jirovecii infection is recognized as a life-threatening condition in human immunodeficiency virus (HIV) infected infants. We recount the use of nasal bubble continuous positive airway pressure (BCPAP) in an HIV-infected African infant with very severe pneumonia and treatment failure due to suspected infection with P. jirovecii. We also examine the potential implications of BCPAP use in resource-poor settings with a high case index of acute respiratory failure due to HIV-related pneumonia, but limited access to mechanical ventilation. PMID:21396221

  20. Behavioral training for increasing preschool children's adherence with positive airway pressure: a preliminary study.

    PubMed

    Slifer, Keith J; Kruglak, Deborah; Benore, Ethan; Bellipanni, Kimberly; Falk, Lroi; Halbower, Ann C; Amari, Adrianna; Beck, Melissa

    2007-01-01

    Behavioral training was implemented to increase adherence with positive airway pressure (PAP) in 4 preschool children. The training employed distraction, counterconditioning, graduated exposure, differential reinforcement, and escape extinction. A non-concurrent multiple baseline experimental design was used to demonstrate program effects. Initially, the children displayed distress and escape-avoidance behavior when PAP was attempted. With training, all 4 children tolerated PAP while sleeping for age appropriate durations. For the 3 children with home follow-up data, the parents maintained benefits. The results are discussed in relation to behavior principles, child health, and common barriers to PAP adherence.

  1. An Examination of Methodological Paradigms for Calculating Upper Airway Critical Pressures during Sleep

    PubMed Central

    Pien, Grace W.; Keenan, Brendan T.; Marcus, Carole L.; Staley, Bethany; Ratcliffe, Sarah J.; Jackson, Nicholas J.; Wieland, William; Sun, Yi; Schwab, Richard J.

    2016-01-01

    Study Objectives: The goal of this study was to examine different paradigms for determining critical closing pressures (Pcrit). Methods of determining Pcrit were compared, including direct observation of occluded (no flow) breaths versus inferring Pcrit from extrapolated data, and Pcrit generated by aggregating pressure-flow data from multiple runs versus Pcrit averaged across individual pressure-flow runs. The relationship between Pcrit and obstructive sleep apnea (OSA) was examined. Methods: A total of 351 participants with and without OSA underwent overnight polysomnography with pressure-flow measurements to determine Pcrit. A series of filters were applied to raw data to provide consistent, objective criteria for determining which data to include in Pcrit calculations. Observed Pcrit values were computed as the mean nasal pressure level at which a subject had at least two breaths with peak inspiratory flow < 50 mL/sec. Extrapolated Pcrit was calculated in two ways: (1) separately for each individual run and then averaged; and (2) using all valid data from individual runs combined into one plot. Results: Observed Pcrit was calculated in 67% to 69% of participants, a similar or higher proportion of study subjects compared to extrapolated Pcrit values using a ± 3 cm H2O filter. Although raw (unfiltered) extrapolated Pcrit measures were able to be calculated among a greater proportion of participants than filtered, extrapolated Pcrit values, and thus had fewer missing values, they had larger variability. Both extrapolated and observed Pcrit were higher among individuals with OSA compared to those without OSA. Conclusions: Observed Pcrit provides a reliable descriptor of hypotonic upper airway collapsibility. Different methods for determining Pcrit were able to distinguish subjects with and without OSA. Citation: Pien GW, Keenan BT, Marcus CL, Staley B, Ratcliffe SJ, Jackson NJ, Wieland W, Sun Y, Schwab RJ. An examination of methodological paradigms for calculating

  2. [Obstruction of the upper airways in humans and animal models].

    PubMed

    Schulz, R

    2010-07-01

    Obstructive sleep apnea (OSA) is caused by repetitive collapse of a narrow upper airway during sleep with the main risk factor being obesity. Apneas are followed by hypoxia, sympathetic activation, intrathoracic pressure swings and arousals. In most animal studies, only the cyclical pattern of hypoxia characteristic of OSA is simulated, however, more complex models have also been developed which additionally reflect the other pathophysiological changes associated with sleep-disordered breathing. These models have contributed to a deeper understanding of the cardiovascular and metabolic consequences of OSA. From other experiments the concept of the pharynx behaving like a collapsible tube, i. e. a Starling resistor, has emerged. Finally, the neurotransmitter modulation of upper airway muscle tone has been elucidated by using IN VIVO microdialysis of the caudal medulla of rats. It is hoped that findings from animal studies will in the future impact on the management of patients with OSA, in particular if they are non-compliant with CPAP therapy. PMID:20632239

  3. Computer simulations of pressure and velocity fields in a human upper airway during sneezing.

    PubMed

    Rahiminejad, Mohammad; Haghighi, Abdalrahman; Dastan, Alireza; Abouali, Omid; Farid, Mehrdad; Ahmadi, Goodarz

    2016-04-01

    In this paper, the airflow field including the velocity, pressure and turbulence intensity distributions during sneezing of a female subject was simulated using a computational fluid dynamics model of realistic upper airways including both oral and nasal cavities. The effects of variation of reaction of the subject during sneezing were also investigated. That is, the impacts of holding the nose or closing the mouth during sneezing on the pressure and velocity distributions were studied. Few works have studied the sneeze and therefore different aspects of this phenomenon have remained unknown. To cover more possibilities about the inlet condition of trachea in different sneeze scenarios, it was assumed that the suppressed sneeze happens with either the same inlet pressure or the same flow rate as the normal sneeze. The simulation results showed that during a normal sneeze, the pressure in the trachea reaches about 7000Pa, which is much higher than the pressure level of about 200Pa during the high activity exhalation. In addition, the results showed that, suppressing the sneeze by holding the nose or mouth leads to a noticeable increase in pressure difference in the tract. This increase was about 5 to 24 times of that during a normal sneeze. This significant rise in the pressure can justify some reported damage due to suppressing a sneeze. PMID:26914240

  4. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway

    PubMed Central

    Grams, Samantha Torres; Kimoto, Karen Yumi Mota; Azevedo, Elen Moda de Oliveira; Lança, Marina; de Albuquerque, André Luis Pereira; de Brito, Christina May Moran; Yamaguti, Wellington Pereira

    2015-01-01

    Introduction Maximal Inspiratory Pressure (MIP) is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway. Objectives This study aimed to compare the MIP values assessed by standard method (MIPsta) and by unidirectional expiratory valve method (MIPuni) in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated. Methods This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B) at two moments (Tests 1 and 2) to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1]) was used to determine intraobserver and interobserver reproducibility. Results The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O) than the mean values for MIPsta (-102.5 ± 23.9 cmH2O) (p<0.001). Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91), and high correlation for Test 2 (ICC[2,1] = 0.88). The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86) and evaluator B (ICC[2,1] = 0.77). Conclusions MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway. PMID:26360255

  5. Treatment of upper airway resistance syndrome in adults: Where do we stand?☆

    PubMed Central

    de Godoy, Luciana B.M.; Palombini, Luciana O.; Guilleminault, Christian; Poyares, Dalva; Tufik, Sergio; Togeiro, Sonia M.

    2015-01-01

    Objective: To evaluate the available literature regarding Upper Airway Resistance Syndrome (UARS) treatment. Methods: Keywords “Upper Airway Resistance Syndrome,” “Sleep-related Breathing Disorder treatment,” “Obstructive Sleep Apnea treatment” and “flow limitation and sleep” were used in main databases. Results: We found 27 articles describing UARS treatment. Nasal continuous positive airway pressure (CPAP) has been the mainstay therapy prescribed but with limited effectiveness. Studies about surgical treatments had methodological limitations. Oral appliances seem to be effective but their efficacy is not yet established. Conclusion: Randomized controlled trials with larger numbers of patients and long-term follow-up are important to establish UARS treatment options. PMID:26483942

  6. Meta-analyses of the Association of Sleep Apnea with Insulin Resistance, and the Effects of CPAP on HOMA-IR, Adiponectin, and Visceral Adipose Fat

    PubMed Central

    Iftikhar, Imran H.; Hoyos, Camilla M.; Phillips, Craig L.; Magalang, Ulysses J.

    2015-01-01

    Objective: We sought to conduct an updated meta-analysis of randomized controlled trials (RCTs) on the effect of continuous positive airway pressure (CPAP) on insulin resistance, as measured by homeostasis model assessment of insulin resistance (HOMA-IR), visceral abdominal fat (VAF), and adiponectin. Additionally, we performed a separate meta-analysis and meta-regression of studies on the association of insulin resistance and obstructive sleep apnea (OSA). Methods: All included studies were searched from PubMed (from conception to March 15, 2014). Data were pooled across all included RCTs as the mean difference in HOMA-IR and VAF, and as the standardized mean difference in the case of adiponectin analysis. From the included case-control studies, data on the difference of HOMA-IR between cases and controls were pooled across all studies, as the standardized mean difference (SMD). Results: There was a significant difference in HOMA-IR (−0.43 [95% CIs: −0.75 to −0.11], p = 0.008) between CPAP treated and non CPAP treated participants. However, there was no significant difference in VAF or adiponectin; (−47.93 [95% CI: −112.58 to 16.72], p = 0.14) and (−0.06 [95% CI: −0.28 to 0.15], p = 0.56), respectively. Meta-analysis of 16 case-control studies showed a pooled SMD in HOMA-IR of 0.51 (95% CI: 0.28 to 0.75), p ≤ 0.001, between cases and controls. Conclusions: The results of our meta-analyses show that CPAP has a favorable effect on insulin resistance. This effect is not associated with any significant changes in total adiponectin levels or amount of VAF. Our findings also confirm a significant association between OSA and insulin resistance. Citation: Iftikhar IH, Hoyos CM, Phillips CL, Magalang UJ. Meta-analyses of the association of sleep apnea with insulin resistance, and the effects of CPAP on HOMA-IR, adiponectin, and visceral adipose fat. J Clin Sleep Med 2015;11(4):475–485. PMID:25700870

  7. Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients

    PubMed Central

    Palomero-Rodríguez, Miguel Angel; de Arteaga, Héctor Chozas; Báez, Yolanda Laporta; de Vicente Sánchez, Jesús; Carretero, Pascual Sanabria; Conde, Pilar Sánchez; Ferrer, Antonio Pérez

    2016-01-01

    Background: Over the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants (“Mapleson D CPAP system”). The primary goal of this study was to assess the usefulness of the “Mapleson D CPAP system” for weaning of mechanical ventilation (MV) in infants who received MV over 24 h. Materials and Methods: All infants who received MV for more than 24 h in the last year were enrolled in the study. Demographic data included age, gender, weight, and admission diagnosis. Heart rate, respiratory rate, blood pressure, and oxygen saturation were measured during MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation. Patients were classified into two groups: patients MV more than 48 h, and patients with MV fewer than 48 h. P < 0.05 was considered statistically significant. Results: A total of 50 children were enrolled in the study, with a median age was 34 ± 45 months (range, 1–59 months) and median weight was 11.98 ± 9.31 kg (range, 1–48 kg). Median duration of MV was 480 h (range, 2–570). There were no significant differences in PaO2, PaCO2, and pH among MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation and spontaneous ventilation with the nasopharyngeal Mapleson D CPAP system or with nasal prongs. The overall extubation failure rate was 26% (n = 13). Weight and age were significantly associated with extubation failure (P < 0.05). Conclusions: The Mapleson D CPAP system, in our opinion, is a useful and safe alternative to more complex and expensive noninvasive CPAP and BiPAP weaning from MV in infants.

  8. Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients

    PubMed Central

    Palomero-Rodríguez, Miguel Angel; de Arteaga, Héctor Chozas; Báez, Yolanda Laporta; de Vicente Sánchez, Jesús; Carretero, Pascual Sanabria; Conde, Pilar Sánchez; Ferrer, Antonio Pérez

    2016-01-01

    Background: Over the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants (“Mapleson D CPAP system”). The primary goal of this study was to assess the usefulness of the “Mapleson D CPAP system” for weaning of mechanical ventilation (MV) in infants who received MV over 24 h. Materials and Methods: All infants who received MV for more than 24 h in the last year were enrolled in the study. Demographic data included age, gender, weight, and admission diagnosis. Heart rate, respiratory rate, blood pressure, and oxygen saturation were measured during MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation. Patients were classified into two groups: patients MV more than 48 h, and patients with MV fewer than 48 h. P < 0.05 was considered statistically significant. Results: A total of 50 children were enrolled in the study, with a median age was 34 ± 45 months (range, 1–59 months) and median weight was 11.98 ± 9.31 kg (range, 1–48 kg). Median duration of MV was 480 h (range, 2–570). There were no significant differences in PaO2, PaCO2, and pH among MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation and spontaneous ventilation with the nasopharyngeal Mapleson D CPAP system or with nasal prongs. The overall extubation failure rate was 26% (n = 13). Weight and age were significantly associated with extubation failure (P < 0.05). Conclusions: The Mapleson D CPAP system, in our opinion, is a useful and safe alternative to more complex and expensive noninvasive CPAP and BiPAP weaning from MV in infants. PMID:27625446

  9. [Successful treatment of diaphragm pacing-induced obstructive sleep apnea syndrome with nasal CPAP].

    PubMed

    Moue, Y; Kamio, K; Tanigaki, T; Hayashi, Y; Kuwahira, I; Takasaki, Y; Ohta, Y; Yamabayashi, H

    1993-08-01

    We report a 71-year-old female patient with primary alveolar hypoventilation syndrome who received diaphragm pacing (DP) and developed obstructive sleep apnea syndrome (OSAS). Application of nCPAP markedly improved her nocturnal hypoxemia. The monitored polygrams before and after the application strongly suggested that the main mechanism of OSAS was an imbalance of activity between upper airway dilator muscles and pump muscles. Moreover, paradoxical movement of the rib cage is not necessarily due to upper airway obstruction. Monitoring of tidal volume and arterial oxygen saturation is essential for the diagnosis of DP-induced OSAS.

  10. Development of a method for manufacturing customized nasal mask cushion for CPAP therapy.

    PubMed

    Hsu, Ding-Yang; Cheng, Yih-Lin; Bien, Mauo-Ying; Lee, Hsin-Chien

    2015-12-01

    A continuous positive airway pressure (CPAP) device is considered one of the most effective treatments for obstructive sleep apnea (OSA). However, many patients receiving this treatment complain of mask discomfort and other issues. Therefore, this study aimed to develop a customized nasal mask cushion to reduce the discomfort associated with conventional masks. First, a 3D face scanner was used to obtain 3D facial data of participants. Second, a model of the face was created by reverse-engineering and then used for the computer-aided design (CAD) of the cushion. Finally, computer numerical control (CNC) was used to manufacture the mold, into which silicone was then injected slowly. A perceived comfort questionnaire was used to compare the customized and conventional cushions. 40 patients were randomly divided into two groups: 20 patients in the control group used a conventional cushion, and the remaining 20 patients used the customized cushion. The customized cushion was found to be superior to the conventional cushion. There are clear differences in the headgear force of the two cushion types (P = 0.001). The customized cushion applied less force to a patient’s face than a conventional cushion. Furthermore, there were obvious differences in the fit of the cushions (P = 0.001). Patients using the customized cushions experienced a better fit than those using the conventional cushions. This study has developed a new method for manufacturing customized cushions with better cushion fit through rapid tooling.

  11. Commercial Motor Vehicle Driver Positive Airway Pressure Therapy Adherence in a Sleep Center

    PubMed Central

    Colvin, Loretta J.; Dace, Gayla A.; Colvin, Ryan M.; Ojile, Joseph; Collop, Nancy

    2016-01-01

    Study Objectives: To assess positive airway pressure (PAP) therapy adherence in commercial motor vehicle (CMV) drivers presenting to a sleep center. Methods: A retrospective chart review of 120 drivers evaluated for obstructive sleep apnea OSA and 53 initiated on PAP therapy in a single sleep center over a one-year period (2012); PAP therapy data were collected up to 1 year. Results: Early PAP usage best predicted adherence up to 1 year (p < 0.0001) compared to patient factors, OSA disease characteristics, and treatment elements analyzed. The proportion of participants adherent to therapy was 68.0% at 1 week, decreasing to 39.6% at 1 year, with 31.1% lost to follow-up by 1 year. In the group categorized based on adherence at week 1, 80.6% were adherent at 1 month, decreasing to 52.8% at 1 year. For the group non-adherent at 1 week, 29.4% were adherent at 1 month, decreasing to 11.7% at 1 year. Participants were predominantly male (75.8%), middle-aged (median 50.5 years), and African American (71.7%). Of those referred to the sleep center, 86.7% had OSA (median apnea-hypopnea index [AHI] or respiratory event index [REI] 20.1), with 51.0% of the OSA group having an AHI or REI > 20 and initiating PAP therapy. Conclusions: Early PAP utilization patterns predicted one year adherence for our CMV driver population within a sleep clinic setting. OSA testing of these CMV drivers after occupational health referral identifies high proportions of undiagnosed OSA, with approximately half requiring PAP therapy based on current published treatment recommendations. Citation: Colvin LJ, Dace GA, Colvin RM, Ojile J, Collop N. Commercial motor vehicle driver positive airway pressure therapy adherence in a sleep center. J Clin Sleep Med 2016;12(4):477–485. PMID:26715403

  12. Does smooth muscle in an intact airway undergo length adaptation during a sustained change in transmural pressure?

    PubMed

    Ansell, Thomas K; McFawn, Peter K; McLaughlin, Robert A; Sampson, David D; Eastwood, Peter R; Hillman, David R; Mitchell, Howard W; Noble, Peter B

    2015-03-01

    In isolated airway smooth muscle (ASM) strips, an increase or decrease in ASM length away from its current optimum length causes an immediate reduction in force production followed by a gradual time-dependent recovery in force, a phenomenon termed length adaptation. In situ, length adaptation may be initiated by a change in transmural pressure (Ptm), which is a primary physiological determinant of ASM length. The present study sought to determine the effect of sustained changes in Ptm and therefore, ASM perimeter, on airway function. We measured contractile responses in whole porcine bronchial segments in vitro before and after a sustained inflation from a baseline Ptm of 5 cmH2O to 25 cmH2O, or deflation to -5 cmH2O, for ∼50 min in each case. In one group of airways, lumen narrowing and stiffening in response to electrical field stimulation (EFS) were assessed from volume and pressure signals using a servo-controlled syringe pump with pressure feedback. In a second group of airways, lumen narrowing and the perimeter of the ASM in situ were determined by anatomical optical coherence tomography. In a third group of airways, active tension was determined under isovolumic conditions. Both inflation and deflation reduced the contractile response to EFS. Sustained Ptm change resulted in a further decrease in contractile response, which returned to baseline levels upon return to the baseline Ptm. These findings reaffirm the importance of Ptm in regulating airway narrowing. However, they do not support a role for ASM length adaptation in situ under physiological levels of ASM lengthening and shortening. PMID:25729015

  13. Can diaphragmatic contractility be assessed by twitch airway pressures in patients with chronic obstructive pulmonary disease?

    PubMed

    Topeli, A; Laghi, F; Tobin, M J

    1999-10-01

    In healthy subjects and in patients without lung diseases, twitch airway pressure (Paw(tw)) responses to phrenic nerve stimulation can be used to predict twitch esophageal pressure (Pes(tw)) and twitch transdiaphragmatic pressure (Pdi(tw)), thus overcoming the need for placement of esophageal and gastric balloons. The aim of this study was to determine whether measurements of Paw(tw) combined with simple maneuvers could be used to predict Pes(tw), and possibly Pdi(tw), in patients with severe chronic obstructive pulmonary disease (COPD) (n = 12). Stimulations delivered at relaxed FRC produced a correlation coefficient (r) between Paw(tw) and Pes(tw) of 0.44 (p < 0.001) and of 0.62 (p < 0.001) during stimulations while patients performed a gentle exhalation from FRC. Stimulations performed during a gentle inhalation produced a good correlation between Paw(tw) and Pes(tw) (r = 0.92, p < 0.001); however, the limits of agreement between Paw(tw) and Pes(tw) were wide. Correlations between Paw(tw) and Pdi(tw) during the three experimental conditions were weak. In conclusion, during a gentle inspiratory effort in patients with severe COPD the correlation between Paw(tw) and Pdi(tw) was weak, whereas the correlation between Paw(tw) and Pes(tw) was good, but it was not sufficient to allow the prediction of Pes(tw) from Paw(tw) in all patients.

  14. Safety and efficacy of bronchoalveolar lavage using a laryngeal mask airway in cases of acute hypoxaemic respiratory failure with diffuse lung infiltrates.

    PubMed

    Matsumoto, Takafumi; Sato, Yoko; Fukuda, Satoshi; Katayama, Shinshu; Miyazaki, Yuya; Ozaki, Makoto; Kotani, Toru

    2015-01-01

    Objective Fibre-optic bronchoscopy with bronchoalveolar lavage (FOB-BAL) is an important tool for diagnosing and selecting treatment for acutely hypoxaemic patients with diffuse lung infiltrates. However, FOB-BAL carries a risk of significant hypoxaemia and subsequent tracheal intubation during and after the procedure. The application of FOB-BAL using a laryngeal mask airway (LMA) in combination with continuous positive airway pressure (CPAP) may minimize the incidence of hypoxaemia; however, the safety and efficacy of this procedure have not been investigated. Methods A retrospective chart review was performed from April to September 2013. Data regarding the recovered volume of BAL fluid, incidence of tracheal intubation within eight hours after the completion of FOB-BAL, respiratory and haemodynamic parameters and treatment modifications were collected for the evaluation. Results Ten trials of FOB-BAL using an LMA and CPAP were performed in nine patients with severe acute hypoxaemia associated with diffuse lung infiltrates. The BAL fluid recovery rate was 56%, and the procedure was completed without subsequent complications. In addition, the percutaneous arterial oxygen saturation decreased to 95.7%±3.8%, although it was never lower than 90.0% during the procedure, and no patients required intubation. Furthermore, the arterial blood pressure significantly but transiently decreased due to sedation, and the procedure yielded diagnostic information in all nine patients. Conclusion FOB-BAL using LMA and CPAP appears to be safe and effective in patients who develop severe acute hypoxaemia. PMID:25832933

  15. Use of a home positive airway pressure device during intraoperative monitored anesthesia care for outpatient surgery.

    PubMed

    Borg, Lindsay; Walters, Tessa L; Siegel, Lawrence C; Dazols, John; Mariano, Edward R

    2016-08-01

    Perioperative positive airway pressure (PAP) is recommended by the American Society of Anesthesiologists for patients with obstructive sleep apnea, but a readily available and personalized intraoperative delivery system does not exist. We present the successful use of a patient's own nasal PAP machine in the operating room during outpatient foot surgery which required addition of a straight adaptor for oxygen delivery and careful positioning of the gas sampling line to permit end-tidal carbox dioxide monitoring. Home PAP machines may provide a potential alternative to more invasive methods of airway management for patients with obstructive sleep apnea under moderate sedation. PMID:27169990

  16. Use of a home positive airway pressure device during intraoperative monitored anesthesia care for outpatient surgery.

    PubMed

    Borg, Lindsay; Walters, Tessa L; Siegel, Lawrence C; Dazols, John; Mariano, Edward R

    2016-08-01

    Perioperative positive airway pressure (PAP) is recommended by the American Society of Anesthesiologists for patients with obstructive sleep apnea, but a readily available and personalized intraoperative delivery system does not exist. We present the successful use of a patient's own nasal PAP machine in the operating room during outpatient foot surgery which required addition of a straight adaptor for oxygen delivery and careful positioning of the gas sampling line to permit end-tidal carbox dioxide monitoring. Home PAP machines may provide a potential alternative to more invasive methods of airway management for patients with obstructive sleep apnea under moderate sedation.

  17. Lung pressures and gas transport during high-frequency airway and chest wall oscillation.

    PubMed

    Khoo, M C; Ye, T H; Tran, N H

    1989-09-01

    The major goal of this study was to compare gas exchange, tidal volume (VT), and dynamic lung pressures resulting from high-frequency airway oscillation (HFAO) with the corresponding effects in high-frequency chest wall oscillation (HFCWO). Eight anesthetized paralyzed dogs were maintained eucapnic with HFAO and HFCWO at frequencies ranging from 1 to 16 Hz in the former and 0.5 to 8 Hz in the latter. Tracheal (delta Ptr) and esophageal (delta Pes) pressure swings, VT, and arterial blood gases were measured in addition to respiratory impedance and static pressure-volume curves. Mean positive pressure (25-30 cmH2O) in the chest cuff associated with HFCWO generation decreased lung volume by approximately 200 ml and increased pulmonary impedance significantly. Aside from this decrease in functional residual capacity (FRC), no change in lung volume occurred as a result of dynamic factors during the course of HFCWO application. With HFAO, a small degree of hyperinflation occurred only at 16 Hz. Arterial PO2 decreased by 5 Torr on average during HFCWO. VT decreased with increasing frequency in both cases, but VT during HFCWO was smaller over the range of frequencies compared with HFAO. delta Pes and delta Ptr between 1 and 8 Hz were lower than the corresponding pressure swings obtained with conventional mechanical ventilation (CMV) applied at 0.25 Hz. delta Pes was minimized at 1 Hz during HFCWO; however, delta Ptr decreased continuously with decreasing frequency and, below 2 Hz, became progressively smaller than the corresponding values obtained with HFAO and CMV.

  18. The relationship between early reversibility test and maximal inspiratory pressure in patients with airway obstruction.

    PubMed

    Ozkaya, Sevket; Dirican, Adem; Kaya, Sule Ozbay; Karanfil, Rabia C; Bayrak, Merve G; Bostancı, Ozgür; Ece, Ferah

    2014-01-01

    Maximal inspiratory pressure (MIP) is a marker for assessing the degree of respiratory muscle dysfunction. Muscle dysfunction represents a pathophysiological feature of chronic obstructive pulmonary disease. We aimed to determinate the MIP value in patients with airway obstruction, to evaluate the change in MIP with bronchodilator drug, and to show the relationship between the changes in MIP and disease characteristics. We evaluated 21 patients with airway obstruction at the Department of Pulmonary Medicine, Samsun Medicalpark Hospital, Samsun, Turkey. We performed pulmonary function tests, measurement of MIP values, and reversibility tests with salbutamol. The baseline spirometry results were: mean forced vital capacity (FVC), 3,017±1,020 mL and 75.8%±20.8%; mean forced expiratory volume in 1 second (FEV1), 1,892±701 mL and 59.2%±18.2%; FEV1/FVC, 62.9%±5.5%; peak expiratory flow, 53%±19%. The pre-bronchodilator MIP value was 62.1±36.9 cmH2O. The reversibility test was found to be positive in 61.9% of patients with salbutamol. The absolute change and percentage of change in FEV1 were 318±223 mL and 19.8%±16.7%, respectively. The MIP value was increased by 5.5 cmH2O (8.8%) and was 67.7±30.3 cmH2O after bronchodilation. There was no significant relationship between age, FEV1, reversibility, and change in MIP with bronchodilator. However, the increase in MIP with bronchodilator drug was higher in patients with low body mass index (<25 kg/m(2)). We noted a 13.1% increase in FVC, a 19.8% increase in FEV1, a 20.2% increase in peak expiratory flow, and an 8.8% increase in MIP with salbutamol. In conclusion; MIP increases with bronchodilator therapy, regardless of changes in lung function, in patients with airway obstruction. The reversibilty test can be used to evaluate change in MIP with salbutamol.

  19. Quantifying the Amount of Bleeding and Associated Changes in Intra-Abdominal Pressure and Mean Airway Pressure in Patients Undergoing Lumbar Fixation Surgeries: A Comparison of Three Positioning Systems

    PubMed Central

    Gupta, Vikas; Abraham, Mary; Punetha, Pankaj; Bundela, Yashpal

    2016-01-01

    Study Design Prospective, randomised controlled, single centre study of 45 patients posted for two level lumbar fixation surgery in the prone position. Purpose To compare intra-abdominal pressure (IAP), mean airway pressure mean airway pressure and blood loss during the spine surgery in prone position using three different positioning systems. Overview of Literature Studies have correlated IAP with the amount of perioperative bleeding. However, IAP and airway pressures while assessing the bleeding comparing two or more prone positioning systems are unclear. Methods This prospective study was conducted on a cohort of 45 patients scheduled for two-level lumbar fixation. Patients were randomly allocated to a spine table, Wilson's frame, and thermomodulated pads. Bladder pressure as an indicator of IAP, mean and peak airway pressures, and blood loss were monitored. Results IAP increased whenever patient position was changed to prone .The increase in pressure was more in the Wilson's frame group but was statistically significant only on prolonged positioning. Adopting the prone position always increased the mean airway pressure, but the increased was significant only in the Wilson's frame group. Mean airway pressure decreased in the spine table group and was statistically significant. The blood loss in the spine table group was significantly less as compared to the other groups. Conclusions Positioning on a spine table results in less blood loss and low mean airway pressure. The Wilson's frame results in high IAP, increased mean airway pressure, and more blood loss. The thermomodulated frame increases mean airway pressure and produces a moderate increase in IAP and airway pressure. PMID:27114757

  20. Mathematical Equations to Predict Positive Airway Pressures for Obstructive Sleep Apnea: A Systematic Review

    PubMed Central

    Camacho, Macario; Riaz, Muhammad; Tahoori, Armin; Certal, Victor; Kushida, Clete A.

    2015-01-01

    Objective. To systematically review the international literature for mathematical equations used to predict effective pressures for positive airway pressure (PAP) devices. Methods. Google Scholar, PubMed, Scopus, Embase, Web of Science, CINAHL, and The Cochrane Library were searched through June 27, 2015. The PRISMA statement was followed. There was no language limitation. Results. 709 articles were screened, fifty were downloaded, and twenty-six studies presented equations that met the inclusion and exclusion criteria. In total, there were 4,436 patients in the development phases and 3,489 patients in the validation phases. Studies performed multiple linear regressions analyses as part of the equation(s) development and included the following variables: physical characteristics, polysomnography data, behavioral characteristics, and miscellaneous characteristics, which were all predictive to a variable extent. Of the published variables, body mass index (BMI) and mean oxygen saturation are the most heavily weighted, while BMI (eighteen studies), apnea-hypopnea index (seventeen studies), and neck circumference (eleven studies) were the variables most frequently used in the mathematical equations. Ten studies were from Asian countries and sixteen were from non-Asian countries. Conclusion. This systematic review identified twenty-six unique studies reporting mathematical equations which are summarized. Overall, BMI and mean oxygen saturation are the most heavily weighted. PMID:26294977

  1. Noninvasive Positive Airway Pressure Treatment in Children Less Than 12 Months of Age.

    PubMed

    Adeleye, Adetayo; Ho, Alice; Nettel-Aguirre, Alberto; Buchhalter, Jeffrey; Kirk, Valerie

    2016-01-01

    Study Objectives. We identified the associated conditions of patients less than 12 months of age who were referred for polysomnogram (PSG) studies. We collated PSG findings and physician interpretation. We determined the correlation between the recommended treatment by the PSG interpreting physician and actual prescribed treatment by the referring or subjects' physician. We determined adherence with noninvasive positive airway pressure (PAP) treatment. Methods. This was a retrospective cohort study. Participants included children less than 12 months of age referred for PSG studies between 2007 and 2012. Results. 92 patients under the age of 12 months were included in the study analysis. Mean (standard deviation, SD) age in days at time of the PSG study was 208.5 (101.2). 35 (38%) patients had a diagnosis of Trisomy 21. Seven (8%) patients had no prior diagnosis. Median (Q1, Q3) apnea hypopnea index (AHI) was 22.5 (11.3-37.0). Agreement between the PSG interpreting physician's recommendation and actual prescribed treatment by the referring or subjects' physician was 85.9% [95% CI 77.1-91.6]. Mean (SD) percentage days with PAP therapy usage more than 4 hours was 25.2% (32). Conclusions. In our experience, despite consistent physician messaging to families, adherence with noninvasive PAP treatment is low. PMID:27445563

  2. Noninvasive Positive Airway Pressure Treatment in Children Less Than 12 Months of Age

    PubMed Central

    Adeleye, Adetayo; Nettel-Aguirre, Alberto; Buchhalter, Jeffrey; Kirk, Valerie

    2016-01-01

    Study Objectives. We identified the associated conditions of patients less than 12 months of age who were referred for polysomnogram (PSG) studies. We collated PSG findings and physician interpretation. We determined the correlation between the recommended treatment by the PSG interpreting physician and actual prescribed treatment by the referring or subjects' physician. We determined adherence with noninvasive positive airway pressure (PAP) treatment. Methods. This was a retrospective cohort study. Participants included children less than 12 months of age referred for PSG studies between 2007 and 2012. Results. 92 patients under the age of 12 months were included in the study analysis. Mean (standard deviation, SD) age in days at time of the PSG study was 208.5 (101.2). 35 (38%) patients had a diagnosis of Trisomy 21. Seven (8%) patients had no prior diagnosis. Median (Q1, Q3) apnea hypopnea index (AHI) was 22.5 (11.3–37.0). Agreement between the PSG interpreting physician's recommendation and actual prescribed treatment by the referring or subjects' physician was 85.9% [95% CI 77.1–91.6]. Mean (SD) percentage days with PAP therapy usage more than 4 hours was 25.2% (32). Conclusions. In our experience, despite consistent physician messaging to families, adherence with noninvasive PAP treatment is low. PMID:27445563

  3. Positive airway pressure improves nocturnal beat-to-beat blood pressure surges in obesity hypoventilation syndrome with obstructive sleep apnea.

    PubMed

    Carter, Jason R; Fonkoue, Ida T; Grimaldi, Daniela; Emami, Leila; Gozal, David; Sullivan, Colin E; Mokhlesi, Babak

    2016-04-01

    Positive airway pressure (PAP) treatment has been shown to have a modest effect on ambulatory blood pressure (BP) in patients with obstructive sleep apnea (OSA). However, there is a paucity of data on the effect of PAP therapy on rapid, yet significant, BP swings during sleep, particularly in obesity hypoventilation syndrome (OHS). The present study hypothesizes that PAP therapy will improve nocturnal BP on the first treatment night (titration PAP) in OHS patients with underlying OSA, and that these improvements will become more significant with 6 wk of PAP therapy. Seventeen adults (7 men, 10 women; age 50.4 ± 10.7 years, BMI 49.3 ± 2.4 kg/m(2)) with OHS and clinically diagnosed OSA participated in three overnight laboratory visits that included polysomnography and beat-to-beat BP monitoring via finger plethysmography. Six weeks of PAP therapy, but not titration PAP, lowered mean nocturnal BP. In contrast, when nocturnal beat-to-beat BPs were aggregated into bins consisting of at least three consecutive cardiac cycles with a >10 mmHg BP surge (i.e., Δ10-20, Δ20-30, Δ30-40, and Δ>40 mmHg), titration, and 6-wk PAP reduced the number of BP surges per hour (time × bin, P < 0.05). PAP adherence over the 6-wk period was significantly correlated to reductions in nocturnal systolic (r = 0.713, P = 0.001) and diastolic (r = 0.497, P = 0.043) BP surges. Despite these PAP-induced improvements in nocturnal beat-to-beat BP surges, 6 wk of PAP therapy did not alter daytime BP. In conclusion, PAP treatment reduces nocturnal beat-to-beat BP surges in OHS patients with underlying OSA, and this improvement in nocturnal BP regulation was greater in patients with higher PAP adherence.

  4. Analysis of heart rate variability in individuals subjected to different positive end expiratory pressure levels using expiratory positive airway pressure

    PubMed Central

    Pinto, Thiago Lorentz; Costa, Ivan Peres; Kawaguchi, Leandro Yukio Alves; de Carvalho, Flávio Aimbire Soares; de Carvalho, Regiane Albertini

    2013-01-01

    Introduction The increase in the number of studies has led to greater security in the application of this method and the determination of its effectiveness in adults.. The purpose of the present study was to evaluate heart rate variability in healthy individuals submitted to different levels of positive expiratory pressure using an expiratory positive airway pressure (EPAP) device. Material and methods The study involved 27 healthy male individuals ranging in age from 20 to 35 years. Patient histories were taken and the subjects were submitted to a physical examination. The volunteers were monitored using the Polar 810s® and submitted to the EPAP experiment. Analyses were performed on variables of the frequency domain. Sympathetic and parasympathetic bands and their relationship with sympathovagal response were also analyzed. Results The mean value of this variable was 526.89 (55.50) ms2 in the first period, 2811.0 (721.10) ms2 in the fourth period and 726.52 (123.41) ms2 in the fifth period. Regarding the parasympathetic area, significant differences were detected when Periods 1 and 5 (no load) were compared with periods in which the individuals were subjected to the use of the therapy. Sympathetic and parasympathetic areas together, a significant difference was detected regarding the sympathetic/parasympathetic ratio in the comparison between Periods 1 and 4 (p < 0.01) as well as Periods 2 and 4 (p < 0.05). Conclusions The findings of the present study suggest that the therapeutic use of EPAP significantly alters the parameters of heart rate variability in the frequency domain, highlighting the importance of monitoring and care during the practice of EPAP. PMID:24049524

  5. Influence of bilevel positive airway pressure on autonomic tone in hospitalized patients with decompensated heart failure

    PubMed Central

    Lacerda, Diego; Costa, Dirceu; Reis, Michel; Gomes, Evelim Leal de F. Dantas; Costa, Ivan Peres; Borghi-Silva, Audrey; Marsico, Aline; Stirbulov, Roberto; Arena, Ross; Sampaio, Luciana Maria Malosá

    2016-01-01

    [Purpose] This study evaluated the effect of Bilevel Positive Airway (BiPAP) on the autonomic control of heart rate, assessed by heart rate variability (HRV), in patients hospitalized with decompensated heart failure. [Subjects and Methods] This prospective cross-sectional study included 20 subjects (age: 69±8 years, 12 male, left ventricular ejection fraction: 36 ±8%) diagnosed with heart failure who were admitted to a semi-intensive care unit with acute decompensation. Date was collected for HRV analysis during: 10 minutes spontaneous breathing in the resting supine position; 30 minutes breathing with BiPAP application (inspiratory pressure = 20 cmH2O and expiratory pressure = 10 cmH2O); and 10 minutes immediately after removal of BiPAP, during the return to spontaneous breathing. [Results] Significantly higher values for indices representative of increased parasympathetic activity were found in the time and frequency domains as well as in nonlinear Poincaré analysis during and after BiPAP in comparison to baseline. Linear HRV analysis: standard deviation of the average of all R-R intervals in milliseconds = 30.99±4.4 pre, 40.3±6.2 during, and 53.3±12.5 post BiPAP. Non-linear HRV analysis: standard deviations parallel in milliseconds = 8.31±4.3 pre, 12.9±5.8 during, and 22.8 ±6.3 post BiPAP. [Conclusion] The present findings demonstrate that BiPAP enhances vagal tone in patients with heart failure, which is beneficial for patients suffering from acute decompensation. PMID:26957719

  6. Effect of airway inflation pressure on forced expiratory maneuvers from raised lung volume in infants.

    PubMed

    Lum, Sooky; Hoo, Ah-Fong; Stocks, Janet

    2002-02-01

    The raised lung volume technique is increasingly used to measure forced expiratory maneuvers in infants. However, there is no consensus regarding the optimal airway inflation pressure (P(inf)) required for such maneuvers, or the influence of small changes in P(inf) within and between infants. The aim of this study was to assess the effect of small differences (0.2-0.3 kPa) in P(inf) on forced vital capacity (FVC), forced expired volume in 0.5 sec (FEV(0.5)), and forced expired flow at 75% of vital capacity (FEF(75)), all derived from the raised volume rapid thoraco-abdominal compression (RVRTC) technique. Randomized paired forced expiratory maneuvers were obtained in 32 healthy infants ( 3.9-39.3 weeks old, 3.8-9.9 kg) with the safety pressure relief valve for P(inf) set to 2.7 kPa or 3.0 kPa (27 or 30 cm H(2)0). When mean (SD) P(inf) was increased by 8.4 (2.8)%, there was a significant (P < 0.01) increase in mean (SD) FVC, FEV(0.5), and FEF(75) by 5.8 (5.7)%, 6.1 (6)%, and 8.3 (16.2)%, respectively. In conclusion, relatively small differences in P(inf) will result in significant differences in FVC, FEV(0.5), and FEF(75) by RVRTC technique. Precision in setting and reporting the applied P(inf) is therefore essential, particularly if data are to be compared between centers.

  7. High Flow Nasal Cannula as a Method for Rapid Weaning From Nasal Continuous Positive Airway Pressure

    PubMed Central

    Badiee, Zohreh; Eshghi, Alireza; Mohammadizadeh, Majid

    2015-01-01

    Background: To compare two methods of weaning premature infants from nasal continuous positive airway pressure (NCPAP). Methods: Between March and November 2012, 88 preterm infants who were stable on NCPAP of 5 cmH2O with FIO2 <30% for a minimum of 6 h were randomly allocated to one of two groups. The high flow nasal cannula (HFNC) group received HFNC with flow of 2 L/min and FIO2 = 0.3 and then stepwise reduction of FIO2 and then flow. The non-HFNC group was maintained on NCPAP of 5 cmH2O and gradual reduction of oxygen until they were on FIO2 = 0.21 for 6 h, and we had weaned them directly from NCPAP (with pressure of 5 cmH2O) to room air. Results: No significant differences were found between 2 study groups with regards to gestational age, birth weight, Apgar score at 1 and 5 min after birth, patent ductus arteriosus and use of xanthines. The mean duration of oxygen therapy after randomization was significantly lower in HFNC group compared to non-HFNC group (20.6 ± 16.8 h vs. 49.6 ± 25.3 h, P < 0.001). Also, the mean length of hospital stay was significantly lower in HFNC group compared to non-HFNC group (11.3 ± 7.8 days vs. 14.8 ± 8.6 days, P = 0.04). The rate of successful weaning was not statistically different between two groups. Conclusions: Weaning from NCPAP to HFNC could decrease the duration of oxygen therapy and length of hospitalization in preterm infants. PMID:25949783

  8. The influence of gender and upper airway resistance on the ventilatory response to arousal in obstructive sleep apnoea in humans

    PubMed Central

    Jordan, Amy S; McEvoy, R Doug; Edwards, Jill K; Schory, Karen; Yang, Chang-Kook; Catcheside, Peter G; Fogel, Robert B; Malhotra, Atul; White, David P

    2004-01-01

    The termination of obstructive respiratory events is typically associated with arousal from sleep. The ventilatory response to arousal may be an important determinant of subsequent respiratory stability/instability and therefore may be involved in perpetuating obstructive respiratory events. In healthy subjects arousal is associated with brief hyperventilation followed by more prolonged hypoventilation on return to sleep. This study was designed to assess whether elevated sleeping upper airway resistance (RUA) alters the ventilatory response to arousal and subsequent breathing on return to sleep in patients with obstructive sleep apnoea (OSA). Inspired minute ventilation (VI), RUA and end-tidal CO2 pressure (PET,CO2) were measured in 22 patients (11 men, 11 women) with OSA (mean ±s.e.m., apnoea–hypopnoea index (AHI) 48.9 ± 5.9 events h−1) during non-rapid eye movement (NREM) sleep with low RUA (2.8 ± 0.3 cmH2O l−1 s; optimal continuous positive airway pressure (CPAP) = 11.3 ± 0.7 cmH2O) and with elevated RUA (17.6 ± 2.8 cmH2O l−1 s; sub-optimal CPAP = 8.4 ± 0.8 cmH2O). A single observer, unaware of respiratory data, identified spontaneous and tone-induced arousals of 3–15 s duration preceded and followed by stable NREM sleep. VI was compared between CPAP levels before and after spontaneous arousal in 16 subjects with tone-induced arousals in both conditions. During stable NREM sleep at sub-optimal CPAP, PET,CO2 was mildly elevated (43.5 ± 0.8 versus 42.5 ± 0.8 Torr). However, baseline VI (7.8 ± 0.3 versus 8.0 ± 0.3 l min−1) was unchanged between CPAP conditions. For the first three breaths following arousal, VI was higher for sub-optimal than optimal CPAP (first breath: 11.2 ± 0.9 versus 9.3 ± 0.6 l min−1). The magnitude of hypoventilation on return to sleep was not affected by the level of CPAP and both obstructive and central respiratory events were rare following arousal. Similar results occurred after tone-induced arousals which led to

  9. Asymmetric spindle pole formation in CPAP-depleted mitotic cells.

    PubMed

    Lee, Miseon; Chang, Jaerak; Chang, Sunghoe; Lee, Kyung S; Rhee, Kunsoo

    2014-02-21

    CPAP is an essential component for centriole formation. Here, we report that CPAP is also critical for symmetric spindle pole formation during mitosis. We observed that pericentriolar material between the mitotic spindle poles were asymmetrically distributed in CPAP-depleted cells even with intact numbers of centrioles. The length of procentrioles was slightly reduced by CPAP depletion, but the length of mother centrioles was not affected. Surprisingly, the young mother centrioles of the CPAP-depleted cells are not fully matured, as evidenced by the absence of distal and subdistal appendage proteins. We propose that the selective absence of centriolar appendages at the young mother centrioles may be responsible for asymmetric spindle pole formation in CPAP-depleted cells. Our results suggest that the neural stem cells with CPAP mutations might form asymmetric spindle poles, which results in premature initiation of differentiation.

  10. Physiological Correlation of Airway Pressure and Transpulmonary Pressure Stress Index on Respiratory Mechanics in Acute Respiratory Failure

    PubMed Central

    Pan, Chun; Chen, Lu; Zhang, Yun-Hang; Liu, Wei; Urbino, Rosario; Ranieri, V Marco; Qiu, Hai-Bo; Yang, Yi

    2016-01-01

    Background: Stress index at post-recruitment maneuvers could be a method of positive end-expiratory pressure (PEEP) titration in acute respiratory distress syndrome (ARDS) patients. However, airway pressure (Paw) stress index may not reflect lung mechanics in the patients with high chest wall elastance. This study was to evaluate the Paw stress index on lung mechanics and the correlation between Paw stress index and transpulmonary pressure (PL) stress index in acute respiratory failure (ARF) patients. Methods: Twenty-four ARF patients with mechanical ventilation (MV) were consecutively recruited from July 2011 to April 2013 in Zhongda Hospital, Nanjing, China and Ospedale S. Giovanni Battista-Molinette Hospital, Turin, Italy. All patients underwent MV with volume control (tidal volume 6 ml/kg) for 20 min. PEEP was set according to the ARDSnet study protocol. The patients were divided into two groups according to the chest wall elastance/respiratory system elastance ratio. The high elastance group (H group, n = 14) had a ratio ≥30%, and the low elastance group (L group, n = 10) had a ratio <30%. Respiratory elastance, gas-exchange, Paw stress index, and PL stress index were measured. Student's t-test, regression analysis, and Bland–Altman analysis were used for statistical analysis. Results: Pneumonia was the major cause of respiratory failure (71.0%). Compared with the L group, PEEP was lower in the H group (5.7 ± 1.7 cmH2O vs. 9.0 ± 2.3 cmH2O, P < 0.01). Compared with the H group, lung elastance was higher (20.0 ± 7.8 cmH2O/L vs. 11.6 ± 3.6 cmH2O/L, P < 0.01), and stress was higher in the L group (7.0 ± 1.9 vs. 4.9 ± 1.9, P = 0.02). A linear relationship was observed between the Paw stress index and the PL stress index in H group (R2= 0.56, P < 0.01) and L group (R2= 0.85, P < 0.01). Conclusion: In the ARF patients with MV, Paw stress index can substitute for PL to guide ventilator settings. Trial Registration: ClinicalTrials.gov NCT02196870 (https

  11. Nasal Expiratory Positive Airway Pressure Devices (Provent) for OSA: A Systematic Review and Meta-Analysis.

    PubMed

    Riaz, Muhammad; Certal, Victor; Nigam, Gaurav; Abdullatif, Jose; Zaghi, Soroush; Kushida, Clete A; Camacho, Macario

    2015-01-01

    Objective. To quantify the effectiveness of nasal expiratory positive airway pressure (nasal EPAP) devices or Provent as treatment for obstructive sleep apnea (OSA). Methods. PubMed and six other databases were searched through November 15, 2015, without language limitations. Results. Eighteen studies (920 patients) were included. Pre- and post-nasal EPAP means ± standard deviations (M ± SD) for apnea-hypopnea index (AHI) in 345 patients decreased from 27.32 ± 22.24 to 12.78 ± 16.89 events/hr (relative reduction = 53.2%). Random effects modeling mean difference (MD) was -14.78 events/hr [95% CI -19.12, -10.45], p value < 0.00001. Oxygen desaturation index (ODI) in 247 patients decreased from 21.2 ± 19.3 to 12.4 ± 14.1 events/hr (relative reduction = 41.5%, p value < 0.00001). Lowest oxygen saturation (LSAT) M ± SD improved in 146 patients from 83.2 ± 6.8% to 86.2 ± 11.1%, MD 3 oxygen saturation points [95% CI 0.57, 5.63]. Epworth Sleepiness Scale (ESS) M ± SD improved (359 patients) from 9.9 ± 5.3 to 7.4 ± 5.0, MD -2.5 [95% CI -3.2, -1.8], p value < 0.0001. Conclusion. Nasal EPAP (Provent) reduced AHI by 53.2%, ODI by 41.5% and improved LSAT by 3 oxygen saturation points. Generally, there were no clear characteristics (demographic factors, medical history, and/or physical exam finding) that predicted favorable response to these devices. However, limited evidence suggests that high nasal resistance could be associated with treatment failure. Additional studies are needed to identify demographic and polysomnographic characteristics that would predict therapeutic success with nasal EPAP (Provent). PMID:26798519

  12. Nasal Expiratory Positive Airway Pressure Devices (Provent) for OSA: A Systematic Review and Meta-Analysis

    PubMed Central

    Riaz, Muhammad; Certal, Victor; Nigam, Gaurav; Abdullatif, Jose; Zaghi, Soroush; Kushida, Clete A.; Camacho, Macario

    2015-01-01

    Objective. To quantify the effectiveness of nasal expiratory positive airway pressure (nasal EPAP) devices or Provent as treatment for obstructive sleep apnea (OSA). Methods. PubMed and six other databases were searched through November 15, 2015, without language limitations. Results. Eighteen studies (920 patients) were included. Pre- and post-nasal EPAP means ± standard deviations (M ± SD) for apnea-hypopnea index (AHI) in 345 patients decreased from 27.32 ± 22.24 to 12.78 ± 16.89 events/hr (relative reduction = 53.2%). Random effects modeling mean difference (MD) was −14.78 events/hr [95% CI −19.12, −10.45], p value < 0.00001. Oxygen desaturation index (ODI) in 247 patients decreased from 21.2 ± 19.3 to 12.4 ± 14.1 events/hr (relative reduction = 41.5%, p value < 0.00001). Lowest oxygen saturation (LSAT) M ± SD improved in 146 patients from 83.2 ± 6.8% to 86.2 ± 11.1%, MD 3 oxygen saturation points [95% CI 0.57, 5.63]. Epworth Sleepiness Scale (ESS) M ± SD improved (359 patients) from 9.9 ± 5.3 to 7.4 ± 5.0, MD −2.5 [95% CI −3.2, −1.8], p value < 0.0001. Conclusion. Nasal EPAP (Provent) reduced AHI by 53.2%, ODI by 41.5% and improved LSAT by 3 oxygen saturation points. Generally, there were no clear characteristics (demographic factors, medical history, and/or physical exam finding) that predicted favorable response to these devices. However, limited evidence suggests that high nasal resistance could be associated with treatment failure. Additional studies are needed to identify demographic and polysomnographic characteristics that would predict therapeutic success with nasal EPAP (Provent). PMID:26798519

  13. Behavior of vascular resistance undergoing various pressure insufflation and perfusion on decellularized lungs.

    PubMed

    da Palma, Renata Kelly; Nonaka, Paula Naomi; Campillo, Noelia; Uriarte, Juan J; Urbano, Jessica Julioti; Navajas, Daniel; Farré, Ramon; Oliveira, Luis V F

    2016-05-01

    Bioengineering of functional lung tissue by using whole lung scaffolds has been proposed as a potential alternative for patients awaiting lung transplant. Previous studies have demonstrated that vascular resistance (Rv) could be altered to optimize the process of obtaining suitable lung scaffolds. Therefore, this work was aimed at determining how lung inflation (tracheal pressure) and perfusion (pulmonary arterial pressure) affect vascular resistance. This study was carried out using the lungs excised from 5 healthy male Sprague-Dawley rats. The trachea was cannulated and connected to a continuous positive airway pressure (CPAP) device to provide a tracheal pressure ranging from 0 to 15cmH2O. The pulmonary artery was cannulated and connected to a controlled perfusion system with continuous pressure (gravimetric level) ranging from 5 to 30cmH2O. Effective Rv was calculated by ratio of pulmonary artery pressure (PPA) by pulmonary artery flow (V'PA). Rv in the decellularized lungs scaffolds decreased at increasing V'PA, stabilizing at a pulmonary arterial pressure greater than 20cmH2O. On the other hand, CPAP had no influence on vascular resistance in the lung scaffolds after being subjected to pulmonary artery pressure of 5cmH2O. In conclusion, compared to positive airway pressure, arterial lung pressure markedly influences the mechanics of vascular resistance in decellularized lungs.

  14. Centrobin-centrosomal protein 4.1-associated protein (CPAP) interaction promotes CPAP localization to the centrioles during centriole duplication.

    PubMed

    Gudi, Radhika; Zou, Chaozhong; Dhar, Jayeeta; Gao, Qingshen; Vasu, Chenthamarakshan

    2014-05-30

    Centriole duplication is the process by which two new daughter centrioles are generated from the proximal end of preexisting mother centrioles. Accurate centriole duplication is important for many cellular and physiological events, including cell division and ciliogenesis. Centrosomal protein 4.1-associated protein (CPAP), centrosomal protein of 152 kDa (CEP152), and centrobin are known to be essential for centriole duplication. However, the precise mechanism by which they contribute to centriole duplication is not known. In this study, we show that centrobin interacts with CEP152 and CPAP, and the centrobin-CPAP interaction is critical for centriole duplication. Although depletion of centrobin from cells did not have an effect on the centriolar levels of CEP152, it caused the disappearance of CPAP from both the preexisting and newly formed centrioles. Moreover, exogenous expression of the CPAP-binding fragment of centrobin also caused the disappearance of CPAP from both the preexisting and newly synthesized centrioles, possibly in a dominant negative manner, thereby inhibiting centriole duplication and the PLK4 overexpression-mediated centrosome amplification. Interestingly, exogenous overexpression of CPAP in the centrobin-depleted cells did not restore CPAP localization to the centrioles. However, restoration of centrobin expression in the centrobin-depleted cells led to the reappearance of centriolar CPAP. Hence, we conclude that centrobin-CPAP interaction is critical for the recruitment of CPAP to procentrioles to promote the elongation of daughter centrioles and for the persistence of CPAP on preexisting mother centrioles. Our study indicates that regulation of CPAP levels on the centrioles by centrobin is critical for preserving the normal size, shape, and number of centrioles in the cell.

  15. Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea: Maximizing Adherence Including Using Novel Information Technology-based Systems.

    PubMed

    Hevener, Bretton; Hevener, William

    2016-09-01

    Sleep apnea is a form of sleep-disordered breathing that is associated with an increase in disease comorbidities, mortality risks, health care costs, and traffic accidents. Sleep apnea is most commonly treated with positive airway pressure (PAP). PAP can be difficult for patients to tolerate. This leads to initial and long-term noncompliance. Most insurance companies require compliance with PAP treatment to cover ongoing reimbursements for the device and related disposable supplies. Therefore, there are both clinical and financial incentives to a sleep apneic patient's compliance with PAP therapy. PMID:27542878

  16. Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea: Maximizing Adherence Including Using Novel Information Technology-based Systems.

    PubMed

    Hevener, Bretton; Hevener, William

    2016-09-01

    Sleep apnea is a form of sleep-disordered breathing that is associated with an increase in disease comorbidities, mortality risks, health care costs, and traffic accidents. Sleep apnea is most commonly treated with positive airway pressure (PAP). PAP can be difficult for patients to tolerate. This leads to initial and long-term noncompliance. Most insurance companies require compliance with PAP treatment to cover ongoing reimbursements for the device and related disposable supplies. Therefore, there are both clinical and financial incentives to a sleep apneic patient's compliance with PAP therapy.

  17. Upper airway collapsibility and patterns of flow limitation at constant end-expiratory lung volume.

    PubMed

    Owens, Robert L; Edwards, Bradley A; Sands, Scott A; Butler, James P; Eckert, Danny J; White, David P; Malhotra, Atul; Wellman, Andrew

    2012-09-01

    The passive pharyngeal critical closing pressure (Pcrit) is measured using a series of pressure drops. However, pressure drops also lower end-expiratory lung volume (EELV), which independently affects Pcrit. We describe a technique to measure Pcrit at a constant EELV. Continuous positive airway pressure (CPAP)-treated obstructive sleep apnea (OSA) patients and controls were instrumented with an epiglottic catheter, magnetometers (to measure change in EELV), and nasal mask/pneumotachograph and slept supine on nasal CPAP. Pcrit was measured in standard fashion and using our novel "biphasic technique" in which expiratory pressure only was lowered for 1 min before the inspiratory pressure was dropped; this allowed EELV to decrease to the drop level before performing the pressure drop. Seven OSA and three controls were studied. The biphasic technique successfully lowered EELV before the inspiratory pressure drop. Pcrit was similar between the standard and biphasic techniques (-0.4 ± 2.6 vs. -0.6 ± 2.3 cmH(2)O, respectively, P = 0.84). Interestingly, we noted three different patterns of flow limitation: 1) classic Starling resistor type: flow fixed and independent of downstream pressure; 2) negative effort dependence within breaths: substantial decrease in flow, sometimes with complete collapse, as downstream pressure decreased; and 3) and negative effort dependence across breaths: progressive reductions in peak flow as respiratory effort on successive breaths increased. Overall, EELV changes do not influence standard passive Pcrit measurements if breaths 3-5 of pressure drops are used. These results also highlight the importance of inspiratory collapse in OSA pathogenesis. The cause of negative effort dependence within and across breaths is not known and requires further study. PMID:22628372

  18. Randomised controlled cross-over comparison of continuous positive airway pressure through the Hamilton Galileo ventilator with a Dräger CF 800 device.

    PubMed

    Sutton, P J; Perkins, C L; Giles, S P; McAuley, D F; Gao, F

    2005-01-01

    In this controlled, randomised cross-over trial on 26 intensive care patients, we compared the effects on haemodynamic and respiratory profiles of continuous positive airway pressure delivered through the Hamilton Galileo ventilator or a Drager CF 800 device. We also compared the nursing time saved using the two approaches when weaning patients from mechanical ventilation. We did not find significant differences in haemodynamics, respiratory rate, physiological dead space, oxygen saturation and carbon dioxide production between the continuous positive airway pressure generated by the Galileo and Drager machines. However, there was a 10-fold reduction in nursing time using the Galileo ventilator compared with the Drager generator. We conclude that continuous positive airway pressure delivered through the Galileo ventilator is as efficient as a Drager device but consumes less nursing time.

  19. Using a modified syringe technique to adjust the intracuff pressure of a laryngeal mask airway.

    PubMed

    Hung, Kuo-Chuan; Chen, Wei-Hung; Shih, Yu-Hsuan; Yeh, Li-Ren

    2015-12-01

    Limiting the intracuff pressure of a laryngeal mask airway (LMA) to <60 cmH2O is recommended in clinical practice. This report aimed to assess the efficacy of a modified syringe technique to adjust the intracuff pressure of an LMA. In a preclinical study, commercially available 20-mL syringes were attached to the pilot balloon of LMAs with different preset intracuff pressures (40 cmH2O, 50 cmH2O, 60 cmH2O, 70 cmH2O, 80 cmH2O, 100 cmH2O, and 120 cmH2O). After attachment, the syringe plunger was allowed to passively rebound. If no rebound of the plunger was observed after attachment, 1 mL of air was withdrawn and the plunger was allowed to passively rebound again. This technique allowed the plunger to overcome static friction and avoid excessive deflation of the LMA cuffs. The intracuff pressure was measured using a manometer after the plunger ceased moving. In the preclinical study, the intracuff pressure was always less than or close to 60 cmH2O after adjustment using this modified syringe technique. After evaluating the performance and characteristics of the syringe in the preclinical study, we concluded that the modified syringe technique may be useful for adjusting LMA intracuff pressure effectively. PMID:25962713

  20. Use of volume-targeted non-invasive bilevel positive airway pressure ventilation in a patient with amyotrophic lateral sclerosis*,**

    PubMed Central

    Diaz-Abad, Montserrat; Brown, John Edward

    2014-01-01

    Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disease in which most patients die of respiratory failure. Although volume-targeted non-invasive bilevel positive airway pressure (BPAP) ventilation has been studied in patients with chronic respiratory failure of various etiologies, its use in ALS has not been reported. We present the case of a 66-year-old woman with ALS and respiratory failure treated with volume-targeted BPAP ventilation for 15 weeks. Weekly data downloads showed that disease progression was associated with increased respiratory muscle weakness, decreased spontaneous breathing, and increased use of non-invasive positive pressure ventilation, whereas tidal volume and minute ventilation remained relatively constant. PMID:25210968

  1. Interaction between otorhinolaryngology and orthodontics: correlation between the nasopharyngeal airway and the craniofacial complex

    PubMed Central

    Stellzig-Eisenhauer, Angelika; Meyer-Marcotty, Philipp

    2011-01-01

    In terms of pathophysiology, an anatomically narrow airway is a predisposing factor for obstruction of the upper respiratory tract. The correlation between the nasopharyngeal airway and the craniofacial structures is discussed in this context. Thus a mutual interaction between the pharynx and the mandibular position was demonstrated, whereby the transverse dimension of the nasopharynx was significantly larger in patients with prognathism than in patients with retrognathism. The influence of chronic obstruction of the nasal airway on craniofacial development was also discussed. The form-and-function interaction, which ought to explain the causal relationship between nasal obstruction and craniofacial growth, appears to be of a multifactorial rather than a one-dimensional, linear nature. It is not disputed, however, that expanding the maxilla improves not only nasal volume and nasal flow, but also the subjective sensation of patients, although it is not possible to make a prognostic statement about the extent of this improvement because of the differing reactions of individuals. Orthodontic appliances for advancing the mandible can also be successfully used in the treatment of mild obstructive sleep apnea syndrome. This treatment method should be considered particularly for patients who are unwilling to undergo or cannot tolerate CPAP (continuous positive airway pressure) treatment. PMID:22073108

  2. Upper Airway Stimulation for Obstructive Sleep Apnea: Past, Present, and Future

    PubMed Central

    Dedhia, Raj C.; Strollo, Patrick J.; Soose, Ryan J.

    2015-01-01

    Obstructive sleep apnea (OSA) is an increasingly prevalent clinical problem with significant effects on both personal and public health. Continuous positive airway pressure (CPAP) has demonstrated excellent efficacy and low morbidity; long-term adherence rates approach 50%. Although traditional upper airway surgical procedures target the anatomic component of obstruction, upper airway stimulation tackles the twin goals of improving anatomic and neuromuscular pathology. After decades of trials demonstrating proof of concept of hypoglossal nerve stimulation in animal and human subjects, the results of a large multicenter, prospective trial were recently published. The trial demonstrated that hypoglossal nerve stimulation led to significant improvements in objective and subjective measurements of the severity of OSA. This novel approach is the first to combine sleep surgery techniques with a titratable medical device for the treatment of OSA. Further research is required to define optimal patient selection and device performance and to demonstrate long-term effectiveness. Citation: Dedhia RC, Strollo PJ, Soose RJ. Upper airway stimulation for obstructive sleep apnea: past, present, and future. SLEEP 2015;38(6):899– 906. PMID:25409109

  3. The effect of sleep on reflex genioglossus muscle activation by stimuli of negative airway pressure in humans.

    PubMed Central

    Horner, R L; Innes, J A; Morrell, M J; Shea, S A; Guz, A

    1994-01-01

    The present study was designed to determine the effect of sleep on reflex pharyngeal dilator muscle activation by stimuli of negative airway pressure in human subjects. Intra-oral bipolar surface electrodes were used to record genioglossus electromyogram (EMG) responses to 500 ms duration pressure stimuli of 0 and -25 cmH2O applied, via a face-mask, in four normal subjects. Stimuli were applied during early inspiration in wakefulness and in periods of non-rapid-eye-movement (non-REM) sleep, defined by electroencephalographic (EEG) criteria. The rectified and integrated EMG responses to repeated interventions were bin averaged for the 0 and -25 cmH2O stimuli applied in wakefulness and sleep. Response latency was defined as the time when the EMG activity significantly increased above prestimulus levels. Response magnitude was quantified as the in ratio of the EMG activity for an 80 ms post-stimulus period to an 80 ms prestimulus period; data from after the subject's voluntary reaction time for tongue protrusion (range, 150-230 ms) were not analysed. Application of the -25 cmH2O stimuli caused genioglossus muscle activation in wakefulness and sleep, but in all subjects response magnitude was reduced in sleep (mean decrease, 61%; range, 52-82%; P = 0.011, Student's paired t test). In addition, response latency was increased in sleep in each subject (mean latency awake, 38 ms; range, 30-50 ms; mean latency asleep, 75 ms; range, 40-110 ms; P = 0.072, Student's paired t test). Application of the -25 cmH2O stimuli caused arousal from sleep on 90% occasions, but in all cases the reflex genioglossus muscle responses (maximum latency, 110 ms) always proceeded any sign of EEG arousal (mean time to arousal, 643 ms; range, 424-760 ms). These results show that non-REM sleep attenuates reflex genioglossus muscle activation by stimuli of negative airway pressure. Attenuation of this reflex by sleep may impair the ability of the upper airway to defend itself from suction collapse by

  4. [Continuous positive airway pressure and high-frequency independent lung ventilation in patients with chronic obstructive lung diseases].

    PubMed

    Fedorova, E A; Vyzhigina, M A; Gal'perin, Iu S; Zhukova, S G; Titov, V A; Godin, A V

    2004-01-01

    The original hypoxemia, hypercapnia, high pulmonary hypertension, high resistance of microcirculation vessels, right volumetric ventricular overload, persistent sub-edema of pulmonary intersticium as well as disparity of ventilation and perfusion between both lungs are the main problems in patients with chronic obstructive disease of the lungs (CODL). Such patients are, as a rule, intolerant to the independent lung collaboration or artificial single-stage ventilation (ASV). Patients with respiratory insufficiency, stages 2 and 3, and with a pronounced impaired type of ventilation have originally a deranged blood gas composition, like hypoxemia or hypercapnia. The application of volume-controllable bi-pulmonary ASV in such patients maintains an adequate gas exchange hemodynamics. However, ASV is accompanied by a significantly reduced gas-exchange function of the single ventilated lung and by essentially worsened intrapulmonary hemodynamics. Therefore, what is needed is to use alternative methods of independent lung ventilation in order to eliminate the gas-exchange impairments and to enable surgical interventions at thoracic organs in such patients (who are intolerant to ASV). A choice of a method and means of oxygen supply to the independent lung is of great importance. The possibility to avoid a high pressure in the airways, while maintaining, simultaneously, an adequate gas exchange, makes the method related with maintaining a constant positive pressure in the airways (CPPA) a priority one in case of CODL patients. The use of constant high-frequency ventilation in the independent lung in patients with obstructive pulmonary lesions does not improve the gas exchange or hemodynamics. Simultaneously, a growing total pulmonary resistance and an increasing pressure in the pulmonary artery are observed. Consequently, the discussed method must not be used for the ventilation support of the independent lung in patients with the obstructive type of the impaired external

  5. Dynamic Characteristics of Mechanical Ventilation System of Double Lungs with Bi-Level Positive Airway Pressure Model

    PubMed Central

    Shen, Dongkai; Zhang, Qian

    2016-01-01

    In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP) controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics.

  6. Dynamic Characteristics of Mechanical Ventilation System of Double Lungs with Bi-Level Positive Airway Pressure Model

    PubMed Central

    Shen, Dongkai; Zhang, Qian

    2016-01-01

    In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP) controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics. PMID:27660646

  7. The effects of prophylactic expiratory positive airway pressure on the resolution of oleic acid-induced lung injury in dogs.

    PubMed Central

    Luce, J M; Huang, T W; Robertson, H T; Colley, P S; Gronka, R; Nessly, M L; Cheney, F W

    1983-01-01

    It is not known whether positive end-expiratory airway pressure (PEEP) merely improves gas exchange in patients with the adult respiratory distress syndrome (ARDS) or if it also affects the resolution of their lung injury. The present investigation was performed to determine whether expiratory positive airway pressure (EPAP), a form of PEEP, is prophylactic in preventing the lung injury induced by oleic acid in dogs or in enhancing its resolution. Arterial and mixed venous blood gases and functional residual capacity (FRC) were measured in 14 pairs of mongrel dogs with indwelling catheters and permanent tracheostomies. One member of each pair was treated with 10 cm H2O EPAP through a valve attached to the tracheostomy tube. Both dogs received 0.06 ml/kg oleic acid intravenously at hour 0. Measurements were made at three, 12, and 24 hours, when EPAP was discontinued, and over the next six days. Five dog pairs were sacrificed at 72 hours; the other surviving animals were sacrificed at 168 hours. FRC was higher at three, 12, and 24 hours in dogs receiving EPAP than in the untreated dogs. The arterial oxygen tension (PaO2) was higher and the venous admixture (Qva/Qt) was lower at three and 12 hours in the dogs receiving EPAP than in the untreated dogs. However, after 24 hours, no differences were noted between the two groups in FRC, PaO2, Qav/Qt, mortality, final lung compliance to initial lung compliance differences, lung water to dry lung weight ratios, or histology. It is concluded that EPAP improves gas exchange during its administration, but has no demonstrable prophylactic effect on the resolution of lung injury in the oleic acid model of human ARDS. Images Fig. 7. Fig. 7. PMID:6338844

  8. A Respiratory Airway-Inspired Low-Pressure, Self-Regulating Valve for Drip Irrigation

    NASA Astrophysics Data System (ADS)

    Wang, Ruo-Qian; Winter, Amos G.; GEAR Lab Team

    2015-11-01

    One of the most significant barriers to achieving large-scale dissemination of drip irrigation is the cost of the pump and power system. An effective means of reducing power consumption is by reducing pumping pressure. The principle source of pressure drop in a drip system is the high flow resistance in the self-regulating flow resistors installed at the outlets of the pips, which evenly distribute water over a field. Traditional architectures require a minimum pressure of ~1 bar to maintain a constant flow rate; our aim is to reduce this pressure by 90% and correspondingly lower pumping power to facilitate the creation of low-cost, off-grid drip irrigation systems. This study presents a new Starling resistor architecture that enables the adjustment of flow rate with a fixed minimum pressure demand of ~0.1 bar. A Starling resistor is a flexible tube subjected to a transmural pressure, which collapses the tube to restrict flow. Our design uses a single pressure source to drive flow through the flexible tube and apply a transmural pressure. Flow into the flexible tube is restricted with a needle valve, to increase the transmural pressure. Using this device, a series of experiments were conducted with different flexible tube diameters, lengths and wall thickness. We found that the resistance of the needle valve changes flow rate but not the minimum transmural pressure required to collapse the tube. A lumped-parameter model was developed to capture the relationships between valve openings, pressure, and flow rates.

  9. Inductance plethysmography: an alternative signal to servocontrol the airway pressure during proportional assist ventilation in small animals.

    PubMed

    Schulze, A; Suguihara, C; Gerhardt, T; Schaller, P; Claure, N; Everett, R; Devia, C; Hehre, D; Bancalari, E

    2001-02-01

    During proportional assist ventilation (PAV), the ventilator pressure is servocontrolled throughout each spontaneous inspiration such that it instantaneously increases in proportion to the airflow (resistive unloading mode), or inspired volume (elastic unloading mode), or both (combined unloading mode). The PAV pressure changes are generated in a closed-loop feedback circuitry commonly using a pneumotachographic signal. In neonates, however, a pneumotachograph increases dead space ventilation, and its signal may include a substantial endotracheal tube leak component. We hypothesized that respiratory inductive plethysmography (RIP) can replace pneumotachography to drive the ventilator during PAV without untoward effects on ventilation or respiratory gas exchange. Ten piglets and five rabbits were supported for 10-min (normal lungs) or 20-min (meconium injured lungs) periods by each of the three PAV modes. In each mode, three test periods were applied in random order with the ventilator driven by the pneumotachograph signal, or the RIP abdominal band signal, or the RIP sum signal of rib cage and abdomen. Interchanging the three input signals did not affect the regularity of spontaneous breathing, and gas exchange was achieved with similar peak and mean airway pressures (ANOVA). However, the RIP sum signal worked adequately only when the relative gains of rib cage and abdominal band signal were calibrated. We conclude that an RIP abdominal band signal can be used to generate PAV, avoiding increased dead space and endotracheal tube leak problems.

  10. Health effects of obstructive sleep apnoea and the effectiveness of continuous positive airways pressure: a systematic review of the research evidence.

    PubMed Central

    Wright, J.; Johns, R.; Watt, I.; Melville, A.; Sheldon, T.

    1997-01-01

    OBJECTIVE: To examine the research evidence for the health consequences of obstructive sleep apnoea and the effectiveness of continuous positive airways pressure. DESIGN: A systematic review of published research, studies being identified by searching Medline (1966-96), Embase (1974-96), and CINAHL (Cumulative Index to Nursing and Allied Health Literature) (1982-95); scanning citations; and consulting experts. Studies in all languages were considered which either investigated the association between obstructive sleep apnoea in adults and key health outcomes or evaluated the effectiveness of treatment of obstructive sleep apnoea with continuous positive airways pressure in adults. MAIN OUTCOME MEASURES: Mortality, systematic hypertension, cardiac arrhythmias, ischaemic heart disease, left ventricular hypertrophy, pulmonary hypertension, stroke, vehicle accidents, measures of daytime sleepiness, and quality of life. RESULTS: 54 epidemiological studies examined the association between sleep apnoea and health related outcomes. Most were poorly designed and only weak or contradictory evidence was found of an association with cardiac arrhythmias, ischaemic heart disease, cardiac failure, systemic or pulmonary hypertension, and stroke. Evidence of a link with sleepiness and road traffic accidents was stronger but inconclusive. Only one small randomised controlled trial evaluated continuous positive airways pressure. Five non-randomised controlled trials and 38 uncontrolled trials were identified. Small changes in objectively measured daytime sleepiness were consistently found, but improvements in morbidity, mortality, and quality of life indicators were not adequately assessed. CONCLUSIONS: The relevance of sleep apnoea to public health has been exaggerated. The effectiveness of continuous positive airways pressure in improving health outcomes has been poorly evaluated. There is enough evidence suggesting benefit in reducing daytime sleepiness in some patients to warrant

  11. Negative extrathoracic pressure ventilation in central hypoventilation syndrome.

    PubMed Central

    Hartmann, H; Jawad, M H; Noyes, J; Samuels, M P; Southall, D P

    1994-01-01

    Nine patients with central hypoventilation syndrome (CHS) were treated with negative extrathoracic pressure ventilation (VNEP). Treatment with VNEP was started between 20 days and 57 months of age, which was two days to 47 months after diagnosis. The equipment to provide VNEP utilised a new system with a latex neck seal and Perspex chamber allowing easy access to the child. Seven patients are managed with VNEP at home by their parents. They did not have a tracheostomy when VNEP was started at ages of 22, 24, 31, 38, and 75 days, 5 and 57 months. They have continued to be successfully managed with VNEP and without tracheostomy. Short periods of intubation and positive pressure ventilation were required on 10 occasions (median duration 7 days, range 4 to 21 days) in four subjects during respiratory tract infections. Three patients required periods of continuous positive airway pressure (CPAP) via a nasal mask or a nasopharyngeal airway during sleep to overcome upper airway obstruction. In three patients the hypoventilation improved and two of these do not require regular ventilatory support at 1.3 and 3.4 years of age. Six of these seven patients are developing normally. In two patients with long term tracheostomies, VNEP could not be established at an age of 29 and 52 months because of tracheal obstruction after temporary removal of their tracheostomy cannula. VNEP is an effective, non-invasive, treatment in infants with CHS if initiated before tracheostomy. It may improve the children's quality of life during the daytime. If upper airway obstruction is a problem in the first year of life, it may be combined with nasal mask CPAP. Images PMID:8017965

  12. Midfacial and Dental Changes Associated with Nasal Positive Airway Pressure in Children with Obstructive Sleep Apnea and Craniofacial Conditions

    PubMed Central

    Roberts, Soleil D.; Kapadia, Hitesh; Greenlee, Geoff; Chen, Maida L.

    2016-01-01

    Study Objectives: Nasal positive airway pressure (nPAP) for treatment of pediatric obstructive sleep apnea (OSA) is a widespread therapy that currently lacks longitudinal data describing how mask pressure impacts the developing facial skeleton. This retrospective cohort study compared midfacial growth in pediatric patients with underlying craniofacial conditions diagnosed with OSA who were compliant vs. noncompliant with nPAP therapy, and explored correlations between demographic, medical, and sleep variables with annual rate of facial change. Methods: Records from Seattle Children's Hospital's Craniofacial Center and Sleep Disorders Center were reviewed to identify patients prescribed nPAP for OSA with serial cephalographic images obtained during routine clinical care for concomitant craniofacial diagnosis. Lateral cephalometric analysis was used to determine mean annual change in midfacial structures from T1 (pre-nPAP) to T2 (post-nPAP) in compliant vs. noncompliant subjects. Compliance was indicated by nPAP usage of > 20 h/week for > 6 months. Results: 50 subjects were compliant with nPAP therapy (mean age 10.42 years) for an average of 2.57 years, and 50 subjects were noncompliant (mean age 8.53 years). Compliant subjects experienced negative mean annual change (retrusion) of the midface compared to forward growth seen in noncompliant subjects (SNA: −0.57° vs. 0.56°), counterclockwise rotation of palatal plane (SN-PP: −1.15° vs. 0.09°), and upper incisor flaring (U1-SN: 2.41° vs. −0.51°). Conclusions: Pressure to the midface from compliant nPAP use may alter normal facial growth. Cephalometric findings indicate a greater need for collaboration between sleep medicine physicians and orthodontists to monitor midfacial growth during nPAP treatment. Citation: Roberts SD, Kapadia H, Greenlee G, Chen ML. Midfacial and dental changes associated with nasal positive airway pressure in children with obstructive sleep apnea and craniofacial conditions. J Clin

  13. The Association Between Antihypertensive Medication and Blood Pressure Control in Patients with Obstructive Sleep Apnea.

    PubMed

    Diogo, Lucília N; Pinto, Paula; Bárbara, Cristina; Papoila, Ana L; Monteiro, Emília C

    2015-01-01

    Obstructive sleep apnea and hypertension are closely related diseases. The lowering effect of continuous positive airway pressure (CPAP) on blood pressure (BP) control is modest and concomitant antihypertensive therapy is still required. However, the best antihypertensive regimen for BP control in patients with OSA remains unknown. We aimed to investigate a hypothetical association between ongoing antihypertensive medication and BP control rates in patients with OSA. We conducted a prospective observational study in a cohort of 205 patients with OSA and hypertension who underwent a sleep study and 24-h ambulatory blood pressure monitoring (ABPM). Ongoing antihypertensive medication profile was recorded. Logistic regression models were used to investigate the association between antihypertensive regimen and BP control, before (n = 205) and, when applicable, after CPAP adaptation (n = 90). One hundred and fifty-five patients (155/205) were being treated with 31 different antihypertensive regimens. At baseline, the antihypertensive regimens and the number of antihypertensive drugs were not associated with BP control (p = 0.847; p = 0.991). After CPAP adaptation, a decrease in median night-time systolic and diastolic BP was observed (p = 0.001; p = 0.006). Nevertheless, the lack of association between antihypertensive regimens and the number of antihypertensive drugs and BP control remained (p = 0.864; p = 0.800). Our findings confirm that although CPAP improves nocturnal BP, this improvement is not sufficient to control blood pressure for 24 h. This study shows, for the first time, that in patients with OSA, there is no association between BP control and both the antihypertensive regimen and the number of antihypertensive drugs. PMID:26303482

  14. Centriolar CPAP/SAS-4 Imparts Slow Processive Microtubule Growth.

    PubMed

    Sharma, Ashwani; Aher, Amol; Dynes, Nicola J; Frey, Daniel; Katrukha, Eugene A; Jaussi, Rolf; Grigoriev, Ilya; Croisier, Marie; Kammerer, Richard A; Akhmanova, Anna; Gönczy, Pierre; Steinmetz, Michel O

    2016-05-23

    Centrioles are fundamental and evolutionarily conserved microtubule-based organelles whose assembly is characterized by microtubule growth rates that are orders of magnitude slower than those of cytoplasmic microtubules. Several centriolar proteins can interact with tubulin or microtubules, but how they ensure the exceptionally slow growth of centriolar microtubules has remained mysterious. Here, we bring together crystallographic, biophysical, and reconstitution assays to demonstrate that the human centriolar protein CPAP (SAS-4 in worms and flies) binds and "caps" microtubule plus ends by associating with a site of β-tubulin engaged in longitudinal tubulin-tubulin interactions. Strikingly, we uncover that CPAP activity dampens microtubule growth and stabilizes microtubules by inhibiting catastrophes and promoting rescues. We further establish that the capping function of CPAP is important to limit growth of centriolar microtubules in cells. Our results suggest that CPAP acts as a molecular lid that ensures slow assembly of centriolar microtubules and, thereby, contributes to organelle length control.

  15. Spontaneously breathing anesthetized patients with a laryngeal mask airway: positive end-expiratory pressure does not improve oxygen saturation.

    PubMed

    Froessler, B; Brommundt, J; Anton, J; Khanduja, R; Kuhlen, R; Rossaint, R; Coburn, M

    2010-11-01

    Spontaneous ventilation is a popular mode of ventilation for patients with the laryngeal mask airway (LMA). Studies have shown, however, that spontaneous ventilation impairs gas exchange and that assisting or controlling ventilation results in higher oxygen saturation. Atelectasis during general anesthesia is a well described mechanism which impacts on gas exchange. Positive end-expiratory pressure (PEEP) increases the lung volume available for gas exchange. This study investigated whether the application of PEEP leads to an improvement of oxygen saturation in unassisted spontaneously breathing patients with a LMA. A total of 80 adult patients under general anesthesia were prospectively randomized into two groups. Both groups were left to breathe spontaneously. In group 1 the adjustable pressure limiting (APL) valve was opened resulting in zero end-expiratory pressure. In group 2 the valve was set to a PEEP of +7 cm H₂O. Oxygen saturation was measured by pulse oxymetry at four different phases: pre-induction, after induction and insertion of the LMA, during maintenance and in recovery. The application of PEEP did not improve oxygen saturation. In both groups the mean oxygen saturation was similar (97.2±1.8% in group 1 versus 97.2±1.9% in group 2, p=0.941) during maintenance. No effect on oxygen saturation in recovery could be found either (96.0±1.8% in group 1 versus 96.1±2.0% in group 2, p=0.952) and hemodynamics were unaffected by the application of PEEP. The application of a PEEP of +7 cm H₂O with a LMA under spontaneous ventilation cannot be recommended. Limitations of our study were the selection of healthy patients and omitting pre-oxygenation before induction which might have limited the development of atelectasis. In addition arterial partial pressure of oxygen (p(a)O₂) measurements could have revealed subtle changes in oxygenation.

  16. Phosphorylation of CPAP by Aurora-A Maintains Spindle Pole Integrity during Mitosis.

    PubMed

    Chou, En-Ju; Hung, Liang-Yi; Tang, Chieh-Ju C; Hsu, Wen-Bin; Wu, Hsin-Yi; Liao, Pao-Chi; Tang, Tang K

    2016-03-29

    CPAP is required for centriole elongation during S/G2 phase, but the role of CPAP in mitosis is incompletely understood. Here, we show that CPAP maintains spindle pole integrity through its phosphorylation by Aurora-A during mitosis. Depletion of CPAP induced a prolonged delay in mitosis, pericentriolar material (PCM) dispersion, and multiple mitotic abnormalities. Further studies demonstrated that CPAP directly interacts with and is phosphorylated by Aurora-A at serine 467 during mitosis. Interestingly, the dispersal of the PCM was effectively rescued by ectopic expression of wild-type CPAP or a phospho-mimic CPAP-S467D mutant, but not a non-phosphorylated CPAP-S467A mutant. Finally, we found that CPAP-S467D has a low affinity for microtubule binding but a high affinity for PCM proteins. Together, our results support a model wherein CPAP is required for proper mitotic progression, and phosphorylation of CPAP by Aurora-A is essential for maintaining spindle pole integrity.

  17. Methods of airway resistance assessment.

    PubMed

    Urbankowski, Tomasz; Przybyłowski, Tadeusz

    2016-01-01

    Airway resistance is the ratio of driving pressure to the rate of the airflow in the airways. The most frequent methods used to measure airway resistance are whole-body plethysmography, the interrupter technique and the forced oscillation technique. All these methods allow to measure resistance during respiration at the level close to tidal volume, they do not require forced breathing manoeuvres or deep breathing during measurement. The most popular method for measuring airway resistance is whole-body plethysmography. The results of plethysmography include among others the following parameters: airway resistance (Raw), airway conductance (Gaw), specific airway resistance (sRaw) and specific airway conductance (sGaw). The interrupter technique is based on the assumption that at the moment of airway occlusion, air pressure in the mouth is equal to the alveolar pressure . In the forced oscillation technique (FOT), airway resistance is calculated basing on the changes in pressure and flow caused by air vibration. The methods for measurement of airway resistance that are described in the present paper seem to be a useful alternative to the most common lung function test - spirometry. The target group in which these methods may be widely used are particularly the patients who are unable to perform spirometry.

  18. Thoracic Block Technique Associated with Positive End-Expiratory Pressure in Reversing Atelectasis

    PubMed Central

    Pereira, Luciana Carnevalli; de Souza Netto, Ana Paula; da Silva, Fernanda Cordeiro; Pereira, Silvana Alves; Moran, Cristiane Aparecida

    2015-01-01

    A preschool four-year-old male patient had been admitted to the Mandaqui Hospital with a diagnosis of lobar pneumonia, pleural effusion, and right lung atelectasis. Treatment consisted of antibiotics and physiotherapy sessions, using a technique described in the literature as Insufflation Technique to Reverse Atelectasis (ITRA), which consists of a thoracic block of healthy lung tissue, leaving only the atelectasis area free, associated with the use of invasive or noninvasive mechanical ventilation with positive airway pressure for reversal of atelectasis. Two physiotherapy sessions were conducted daily. The sessions lasted 20 minutes and were fractionated into four series of five minutes each. Each series bilateral thoracic block was performed for 20 seconds with a pause lasting for the same time. Associated with the thoracic block, a continuous positive airways pressure was used using a facial mask and 7 cm H2O PEEP provided via CPAP. Conclusion. ITRA technique was effective in reversing atelectasis in this patient. PMID:25883824

  19. Effect of early application of biphasic positive airway pressure on the outcome of extubation in ventilator weaning.

    PubMed

    Jiang, J S; Kao, S J; Wang, S N

    1999-06-01

    Extubation failure is significantly associated with increased morbidity and mortality in mechanically ventilated patients. In respiratory distress after extubation, non-invasive positive pressure ventilation (NIPPV) has been suggested to avoid the complications of invasive mechanical ventilation. The purpose of this study was to evaluate the effect of early application of NIPPV on extubation outcome. We conducted a prospective study in 93 extubated patients with a mean age of 72.7 +/- 14.7 years (range, 24-93). Elective extubation was performed in 56 patients and unplanned extubation occurred in 37 patients. After extubation, patients randomly received either biphasic positive airway pressure (BIPAP) therapy (n = 47) or unassisted oxygen therapy (n = 46). Non-invasive positive pressure ventilation was delivered via face mask in BIPAP group. Of the 93 extubated patients, 73 (78.5%) were successfully extubated, and 20 (21.5%) had to be re-intubated. There were no significant differences in age, sex, pre-extubation blood gas data between re-intubated patients and those who were not re-intubated. While seven of the 46 patients in the unassisted oxygen therapy group required re-intubation, 13 of the 47 BIPAP-treated patients also required re-intubation. This difference was not statistically significant. The postextubation respiratory management, BIPAP or unassisted oxygen therapy, did not correlate with the extubation outcome, but the elective extubation had significantly better outcome than unplanned extubation. Patients with excessive bronchial secretions and intolerance to the equipment are poor candidates for NIPPV. We conclude that early application of BIPAP support did not predict a favourable extubation outcome. Our experience did not support the indiscriminate use of NIPPV to facilitate ventilator weaning.

  20. Randomized comparison of oxygen mask treatment vs. nasal continuous positive airway pressure in dengue shock syndrome with acute respiratory failure.

    PubMed

    Cam, B V; Tuan, D T; Fonsmark, L; Poulsen, A; Tien, N M; Tuan, H M; Heegaard, E D

    2002-12-01

    Dengue hemorrhagic fever (DHF) is caused by dengue virus. Patients with DHF grade 3-4, termed Dengue Shock Syndrome (DSS), may develop acute respiratory failure after initial fluid resuscitation. Previously, these patients were treated with oxygen on a nasal cannula, or if necessary with tracheal intubation and mechanical ventilation. In the present prospective randomized study, we compared the effectiveness of oxygen treatment administered by a face mask vs. nasal continuous positive airway pressure (NCPAP). Morbidity, mortality, and supportive treatment was evaluated. Thirty-seven patients with DSS complicated by respiratory failure were enrolled. On admission and after 30 min of treatment, clinical and paraclinical data were obtained. Chest X-ray revealed pleural effusion in 92 per cent and showed interstitial oedema in 33 per cent. After 30 min of treatment the respiratory rate decreased significantly in the NCPAP group (p < 0.05), while SaO2 and PaO2 increased in both groups (p < 0.01). However, subsequently a significant difference of unresponsiveness to treatment between the oxygen mask group and the NCPAP group (13/19 vs. 4/18,p < 0.01) was noted. Complications of NCPAP or oxygen mask treatment were not documented. We conclude that NCPAP is useful in improving the management of acute respiratory failure in children with DHF/DSS in dengue-endemic areas.

  1. Quality of life among untreated sleep apnea patients compared with the general population and changes after treatment with positive airway pressure.

    PubMed

    Bjornsdottir, Erla; Keenan, Brendan T; Eysteinsdottir, Bjorg; Arnardottir, Erna Sif; Janson, Christer; Gislason, Thorarinn; Sigurdsson, Jon Fridrik; Kuna, Samuel T; Pack, Allan I; Benediktsdottir, Bryndis

    2015-06-01

    Obstructive sleep apnea leads to recurrent arousals from sleep, oxygen desaturations, daytime sleepiness and fatigue. This can have an adverse impact on quality of life. The aims of this study were to compare: (i) quality of life between the general population and untreated patients with obstructive sleep apnea; and (ii) changes of quality of life among patients with obstructive sleep apnea after 2 years of positive airway pressure treatment between adherent patients and non-users. Propensity score methodologies were used in order to minimize selection bias and strengthen causal inferences. The enrolled obstructive sleep apnea subjects (n = 822) were newly diagnosed with moderate to severe obstructive sleep apnea who were starting positive airway pressure treatment, and the general population subjects (n = 742) were randomly selected Icelanders. The Short Form 12 was used to measure quality of life. Untreated patients with obstructive sleep apnea had a worse quality of life when compared with the general population. This effect remained significant after using propensity scores to select samples, balanced with regard to age, body mass index, gender, smoking, diabetes, hypertension and cardiovascular disease. We did not find significant overall differences between full and non-users of positive airway pressure in improvement of quality of life from baseline to follow-up. However, there was a trend towards more improvement in physical quality of life for positive airway pressure-adherent patients, and the most obese subjects improved their physical quality of life more. The results suggest that co-morbidities of obstructive sleep apnea, such as obesity, insomnia and daytime sleepiness, have a great effect on life qualities and need to be taken into account and addressed with additional interventions. PMID:25431105

  2. Application of positive airway pressure in restoring pulmonary function and thoracic mobility in the postoperative period of bariatric surgery: a randomized clinical trial

    PubMed Central

    Brigatto, Patrícia; Carbinatto, Jéssica C.; Costa, Carolina M.; Montebelo, Maria I. L.; Rasera-Júnior, Irineu; Pazzianotto-Forti, Eli M.

    2014-01-01

    Objective: To evaluate whether the application of bilevel positive airway pressure in the postoperative period of bariatric surgery might be more effective in restoring lung volume and capacity and thoracic mobility than the separate application of expiratory and inspiratory positive pressure. Method: Sixty morbidly obese adult subjects who were hospitalized for bariatric surgery and met the predefined inclusion criteria were evaluated. The pulmonary function and thoracic mobility were preoperatively assessed by spirometry and cirtometry and reevaluated on the 1st postoperative day. After preoperative evaluation, the subjects were randomized and allocated into groups: EPAP Group (n=20), IPPB Group (n=20) and BIPAP Group (n=20), then received the corresponding intervention: positive expiratory pressure (EPAP), inspiratory positive pressure breathing (IPPB) or bilevel inspiratory positive airway pressure (BIPAP), in 6 sets of 15 breaths or 30 minutes twice a day in the immediate postoperative period and on the 1st postoperative day, in addition to conventional physical therapy. Results: There was a significant postoperative reduction in spirometric variables (p<0.05), regardless of the technique used, with no significant difference among the techniques (p>0.05). Thoracic mobility was preserved only in group BIPAP (p>0.05), but no significant difference was found in the comparison among groups (p>0.05). Conclusion: The application of positive pressure does not seem to be effective in restoring lung function after bariatric surgery, but the use of bilevel positive pressure can preserve thoracic mobility, although this technique was not superior to the other techniques. PMID:25590448

  3. Computational simulation of human upper airway collapse using a pressure-/state-dependent model of genioglossal muscle contraction under laminar flow conditions

    PubMed Central

    Huang, Yaqi; Malhotra, Atul; White, David P.

    2012-01-01

    A three-element, pressure- and state (sleep and wake) -dependent contraction model of the genioglossal muscle was developed based on the microstructure of skeletal muscle and the cross-bridge theory. This model establishes a direct connection between the contractile forces generated in muscle fibers and the measured electromyogram signals during various upper airway conditions. This effectively avoids the difficulty of determining muscle shortening velocity during complex pharyngeal conditions when modeling the muscle’s contractile behaviors. The activation of the genioglossal muscle under different conditions was then simulated. A sensitivity analysis was performed to determine the effects of varying each modeled parameter on the muscle’s contractile behaviors. This muscle contraction model was then incorporated into our anatomically correct, two-dimensional computational model of the pharyngeal airway to perform a finite-element analysis of air flow, tissue deformation, and airway collapse. The model-predicted muscle deformations are consistent with previous observations regarding upper airway behavior in normal subjects. PMID:15831800

  4. CEP120 interacts with CPAP and positively regulates centriole elongation.

    PubMed

    Lin, Yi-Nan; Wu, Chien-Ting; Lin, Yu-Chih; Hsu, Wen-Bin; Tang, Chieh-Ju C; Chang, Ching-Wen; Tang, Tang K

    2013-07-22

    Centriole duplication begins with the formation of a single procentriole next to a preexisting centriole. CPAP (centrosomal protein 4.1-associated protein) was previously reported to participate in centriole elongation. Here, we show that CEP120 is a cell cycle-regulated protein that directly interacts with CPAP and is required for centriole duplication. CEP120 levels increased gradually from early S to G2/M and decreased significantly after mitosis. Forced overexpression of either CEP120 or CPAP not only induced the assembly of overly long centrioles but also produced atypical supernumerary centrioles that grew from these long centrioles. Depletion of CEP120 inhibited CPAP-induced centriole elongation and vice versa, implying that these proteins work together to regulate centriole elongation. Furthermore, CEP120 was found to contain an N-terminal microtubule-binding domain, a C-terminal dimerization domain, and a centriolar localization domain. Overexpression of a microtubule binding-defective CEP120-K76A mutant significantly suppressed the formation of elongated centrioles. Together, our results indicate that CEP120 is a CPAP-interacting protein that positively regulates centriole elongation.

  5. Influence of body position on the displacement of nasal prongs in preterm newborns receiving continuous positive airway pressure

    PubMed Central

    Brunherotti, Marisa Afonso Andrade; Martinez, Francisco Eulógio

    2015-01-01

    Abstract Objective: To evaluate the influence of body position on the displacement of nasal prongs in preterm infants. Methods: This prospective, randomized, crossover study enrolled infants born at a mean gestational age of 29.7±2 weeks, birth weight of 1353±280g and 2.9±2.2 days of life, submitted to continuous positive airway pressure by nasal prongs. The main outcome was the number of times that the nasal prongs were displaced following infant positioning in the following body positions: prone, right lateral, left lateral, and supine, according to a pre-established random order. Moreover, cardiorespiratory variables (respiratory rate, heart rate, and oxygen saturation) were evaluated for each body position. Data for each position were collected every 10 min, over a period of 60 min. An occurrence was defined when the nasal prongs were displaced from the nostrils after 3 min in the desired position, requiring intervention of the examiner. Results: Among the 16 studied infants, the occurrence of nasal prong displacement was only observed in the prone position (9 infants - 56.2%) and in the left lateral position (2 infants - 12.5%). The number of times that the prongs were displaced was 11 in the prone position (7 within the first 10min) and 2 in the left lateral position (1 within the first 10min). No clinically significant changes were observed in the cardiorespiratory variables. Conclusions: Maintenance of the nasal prongs to provide adequate noninvasive respiratory support was harder in the prone position. PMID:26116326

  6. Surgical Airway

    PubMed Central

    Patel, Sapna A; Meyer, Tanya K

    2014-01-01

    Close to 3% of all intubation attempts are considered difficult airways, for which a plan for a surgical airway should be considered. Our article provides an overview of the different types of surgical airways. This article provides a comprehensive review of the main types of surgical airways, relevant anatomy, necessary equipment, indications and contraindications, preparation and positioning, technique, complications, and tips for management. It is important to remember that the placement of a surgical airway is a lifesaving procedure and should be considered in any setting when one “cannot intubate, cannot ventilate”. PMID:24741501

  7. Causes of the difficult airway.

    PubMed

    Orfanos, John G; Quereshy, Faisal A

    2010-03-01

    Recognizing a potentially difficult airway is important in avoiding a life-threatening emergency. There are 2 separate scenarios for considering the difficult airway: difficult mask ventilation (DMV) and difficult tracheal intubation (DTI). DMV can be described as lacking the ability to maintain oxygen saturation or lacking the ability to reverse signs of inadequate ventilation with positive-pressure mask ventilation under general anesthesia. DTI remains constant among anesthesia-related patient injuries, and is the third most common respiratory-related episode leading to death and possible brain damage. It is important to preoperatively assess every patient by completing a full history and physical. A thorough history can provide clues in detecting a possible difficult airway. Airway impairment has been further subdivided into the anatomic regions that affect the airway, namely above the larynx, supraglottic, glottic, subglottic, and tracheobronchial. This article discusses the factors that can result in a difficult airway.

  8. Determination of Mother Centriole Maturation in CPAP-Depleted Cells Using the Ninein Antibody

    PubMed Central

    Lee, Miseon

    2015-01-01

    Background Mutations in centrosomal protein genes have been identified in a number of genetic diseases in brain development, including microcephaly. Centrosomal P4.1-associated protein (CPAP) is one of the causal genes implicated in primary microcephaly. We previously proposed that CPAP is essential for mother centriole maturation during mitosis. Methods We immunostained CPAP-depleted cells using the ninein antibody, which selectively detects subdistal appendages in mature mother centrioles. Results Ninein signals were significantly impaired in CPAP-depleted cells. Conclusion The results suggest that CPAP is required for mother centriole maturation in mammalian cells. The selective absence of centriolar appendages in young mother centrioles may be responsible for asymmetric spindle pole formation in CPAP-depleted cells. PMID:25827458

  9. Effect of Early Intervention With Positive Airway Pressure Therapy for Sleep Disordered Breathing on Six-Month Readmission Rates in Hospitalized Patients With Heart Failure.

    PubMed

    Sharma, Sunil; Mather, Paul; Gupta, Ankit; Reeves, Gordon; Rubin, Sharon; Bonita, Raphael; Chowdhury, Anindita; Malloy, Raymond; Willes, Leslee; Whellan, David

    2016-03-15

    Rehospitalization for congestive heart failure (CHF) is high within 6 months of discharge. Sleep disordered breathing (SDB) is common and underdiagnosed condition in patients with CHF. We hypothesized that early recognition and treatment of SDB in hospitalized patients with CHF will reduce hospital readmissions and emergency room visits. Patients admitted for CHF underwent overnight polysomnography within 4 weeks of discharge. Patients diagnosed with SDB were provided therapy with positive airway pressure therapy. Patients were identified as having good compliance if the device use was for a minimum of 4 hours 70% of the time for a minimum of 4 weeks during the first 3 months of therapy. Hospital admissions for 6 months before therapy were compared with readmission within 6 months after therapy in patients with good and poor compliance. A total of 70 patients were diagnosed with SDB after discharge. Of the 70 patients, 37 (53%) were compliant with positive airway pressure therapy. Compliant patients were more likely to be older (64 ± 12 vs 58 ± 11 years) and women (54% vs 33%) and less likely to be patient with diabetes (40% vs 67%) versus noncompliant patients. Although both groups experienced a decrease in total readmissions, compliant patients had a significant reduction (mean ± SE: -1.5 ± 0.2 clinical events vs -0.2 ± 0.3; p <0.0001). In this single-center analysis, identification and treatment of SDB in admitted patients with CHF with SDB is associated with reduced readmissions over 6 months after discharge. Adherence to the treatment was associated with a greater reduction in clinical events. PMID:26830259

  10. Effect of CPAP on Endothelial Function in Subjects With Obstructive Sleep Apnea: A Meta-Analysis.

    PubMed

    Xu, Huajun; Wang, Yuyu; Guan, Jian; Yi, Hongliang; Yin, Shankai

    2015-05-01

    Obstructive sleep apnea (OSA) is related to endothelial dysfunction. CPAP is the first-line treatment for OSA. We conducted a meta-analysis to evaluate the effect of CPAP on endothelial function in subjects with OSA. The PubMed, Embase, and Cochrane Library databases were searched. The overall effects were measured by the weighted mean difference with a 95% CI. Subgroup and meta-regression analyses were used to explore the sources of between-study heterogeneity. Eleven studies were eligible for the meta-analysis. A random-effects model revealed that CPAP significantly improved endothelial function as assessed by flow-mediated dilation (weighted mean difference of 2.92, 95% CI 2.21-3.63, P < .001), whereas there was no significant improvement in endothelial function in response to nitroglycerin-mediated dilation (weighted mean difference of 0.90, 95% CI -1.63 to 3.43, P = .48). Age, sex, CPAP compliance and duration, and sleep-related variables had no effect on reduction in arterial stiffness after CPAP. Sensitivity analyses indicated that the protective effect of CPAP on endothelial function was robust. CPAP significantly improved flow-mediated dilation in subjects with OSA. Long-term randomized controlled trials with larger sample sizes are needed to confirm the positive effect of CPAP on endothelial function in subjects with OSA.

  11. Total airway reconstruction.

    PubMed

    Connor, Matthew P; Barrera, Jose E; Eller, Robert; McCusker, Scott; O'Connor, Peter

    2013-02-01

    We present a case of obstructive sleep apnea (OSA) that required multilevel surgical correction of the airway and literature review and discuss the role supraglottic laryngeal collapse can have in OSA. A 34-year-old man presented to a tertiary otolaryngology clinic for treatment of OSA. He previously had nasal and palate surgeries and a Repose tongue suspension. His residual apnea hypopnea index (AHI) was 67. He had a dysphonia associated with a true vocal cord paralysis following resection of a benign neck mass in childhood. He also complained of inspiratory stridor with exercise and intolerance to continuous positive airway pressure. Physical examination revealed craniofacial hypoplasia, full base of tongue, and residual nasal airway obstruction. On laryngoscopy, the paretic aryepiglottic fold arytenoid complex prolapsed into the laryngeal inlet with each breath. This was more pronounced with greater respiratory effort. Surgical correction required a series of operations including awake tracheostomy, supraglottoplasty, midline glossectomy, genial tubercle advancement, maxillomandibular advancement, and reconstructive rhinoplasty. His final AHI was 1.9. Our patient's supraglottic laryngeal collapse constituted an area of obstruction not typically evaluated in OSA surgery. In conjunction with treating nasal, palatal, and hypopharyngeal subsites, our patient's supraglottoplasty represented a key component of his success. This case illustrates the need to evaluate the entire upper airway in a complicated case of OSA. PMID:22965285

  12. Comparison of Four Different Supraglottic Airway Devices in Terms of Efficacy, Intra-ocular Pressure and Haemodynamic Parameters in Children Undergoing Ophthalmic Surgery

    PubMed Central

    Peker, Gökhan; Takmaz, Suna Akın; Baltacı, Bülent; Başar, Hülya; Kotanoğlu, Mustafa

    2015-01-01

    Objective The aim of this study was to compare insertion parameters of four different types of supraglottic airway devices (SGAD) (Classic LMA, I-gel LMA, Proseal LMA, Cobra PLA) in children undergoing ophthalmic surgery and to determine the effect on intra-ocular pressure (IOP) and haemodynamic responses during insertion. Methods Sixty American society of Anesthesiologists (ASA) I–II children aged 1–10 years undergoing extra-ocular ophthalmic surgery were randomly divided into four groups (Group LMA, Group I-gel LMA, Group PLMA and Group CPLA) in this prospective, randomised study. Anaesthesia was induced with decreasing sevoflurane concentrations (8%–2%) in a mixture of 50% N2O-O2. All SGADs were inserted under deep anaesthesia. The characteristics of insertion (number of attempts, ease and time), oropharyngeal leak pressure (OLP) and complications were recorded. IOP in both eyes, heart rate (HR), mean arterial pressure (MAP) and EtCO2 were measured before and 2 and 5 min after insertion of the SGADs. Results There was no difference between the groups in terms of the characteristics of insertion. The mean IOP did not increase significantly in all groups. MAP and HR changes were similar among the groups during follow-up. In all groups, HR increased 2 min after insertion (statistically insignificant) and returned to the baseline value 5 min after insertion. A statistically significant correlation was seen between HR increase and IOP values before and after insertion of the SGADs (p=0.006, correlation coefficient=0.352). Desaturation was seen in one patient in Groups LMA, PLMA and CPLA, and laryngospasm was seen in two patients in Group CPLA and in one patient in Group LMA. Conclusion It was seen that during insertion of Classic LMA, I-gel LMA, Proseal LMA and Cobra PLA, IOP did not increase and haemodynamic stability was maintained in children undergoing extra-ocular ophthalmic surgery. PMID:27366519

  13. The effect of treating obstructive sleep apnea with positive airway pressure on depression and other subjective symptoms: A systematic review and meta-analysis.

    PubMed

    Gupta, Madhulika A; Simpson, Fiona C; Lyons, Danika C A

    2016-08-01

    Patients with obstructive sleep apnea (OSA) frequently present with symptoms of depression and anxiety. The objective of this study is to determine if treatment with positive airway pressure (PAP) improves symptoms of depression and anxiety. A systematic review was conducted to identify clinical trials of PAP that contained a validated measure of depression severity. Meta-analysis was conducted for depression, anxiety, excessive daytime sleepiness (EDS), quality of life (QoL) and respiratory variables. The systematic review included 33 reports. Pre-post-test analysis of PAP showed a moderate effect size (Hedge's g, 95% CI) for depression 0.524 [0.401-0.647], but a low effect size compared to oral placebo (0.355 [0.187-0.524]) and no effect when compared to dental appliances (0.107 [-0.72-0.287]) and sham PAP (-0.049 [-0.292-0.194]). Anxiety, EDS, and QoL showed similar improvement in pre-post-test analysis, but a lack of superiority to dental appliances and sham PAP. PAP was superior to all comparators for respiratory variables. PAP has a moderate clinical effect on symptoms of depression and anxiety in OSA, but it is not superior to dental appliances or sham PAP. The improvement in subjective symptoms, such as depression and anxiety, may be mediated by patient expectations and contact with healthcare providers.

  14. Influence of sleep onset on upper-airway muscle activity in apnea patients versus normal controls.

    PubMed

    Mezzanotte, W S; Tangel, D J; White, D P

    1996-06-01

    Current evidence suggests that patients with obstructive sleep apnea (OSA) may have augmented pharyngeal dilator muscle activity during wakefulness, to compensate for deficient anatomy. However, the isolated effect of sleep on the activity of these muscles (comparing OSA patients with controls) has not been studied. We therefore determined waking levels of genioglossus (GG) and tensor palatini (TP) muscle activity (% of maximum electromyographic [EMG] activity) in 10 OSA patients and eight controls, and then assessed the impact of the first two breaths of sleep (theta electroencephalographic [EEG] activity) following a period of stable wakefulness. Apnea patients demonstrated greater genioglossal (27.4 +/- 4.0 versus 10.7 +/- 2.1%) and tensor palatini (31.9 +/- 6.5 versus 10.6 +/- 1.9%) EMG activity than did controls during wakefulness. This augmented muscle activity in apnea patients could be reduced to near control levels during wakefulness with the application of continuous positive airway pressure (CPAP) to the upper airway. At sleep onset, control subjects demonstrated small but consistent decrements in the activity of both the TP and GG muscles. On the other hand, apnea patients demonstrated large, significantly greater decrements in TP EMG at sleep onset than did the control subjects. The effect of sleep on GG EMG in apnea patients was inconsistent, with most (n = 7) demonstrating large (significantly larger than controls) decrements in genioglossal activity. However, three OSA patients demonstrated small increments in GG EMG at sleep onset despite falling TP EMG and obstructive apnea or hypopnea. We conclude that sleep onset is associated with significantly larger decrements in TP muscle EMG activity in OSA patients than in controls, which may represent a loss of neuromuscular compensation that is present during wakefulness. However, our results for the GG muscle were more variable, and did not always support this hypothesis.

  15. Estimation of airway obstruction using oximeter plethysmograph waveform data

    PubMed Central

    Arnold, Donald H; Spiro, David M; Desmond, Renee' A; Hagood, James S

    2005-01-01

    Background Validated measures to assess the severity of airway obstruction in patients with obstructive airway disease are limited. Changes in the pulse oximeter plethysmograph waveform represent fluctuations in arterial flow. Analysis of these fluctuations might be useful clinically if they represent physiologic perturbations resulting from airway obstruction. We tested the hypothesis that the severity of airway obstruction could be estimated using plethysmograph waveform data. Methods Using a closed airway circuit with adjustable inspiratory and expiratory pressure relief valves, airway obstruction was induced in a prospective convenience sample of 31 healthy adult subjects. Maximal change in airway pressure at the mouthpiece was used as a surrogate measure of the degree of obstruction applied. Plethysmograph waveform data and mouthpiece airway pressure were acquired for 60 seconds at increasing levels of inspiratory and expiratory obstruction. At each level of applied obstruction, mean values for maximal change in waveform area under the curve and height as well as maximal change in mouth pressure were calculated for sequential 7.5 second intervals. Correlations of these waveform variables with mouth pressure values were then performed to determine if the magnitude of changes in these variables indicates the severity of airway obstruction. Results There were significant relationships between maximal change in area under the curve (P < .0001) or height (P < 0.0001) and mouth pressure. Conclusion The findings suggest that mathematic interpretation of plethysmograph waveform data may estimate the severity of airway obstruction and be of clinical utility in objective assessment of patients with obstructive airway diseases. PMID:15985171

  16. Acute Effects of Continuous Positive Air way Pressure on Pulse Pressure in Chronic Heart Failure

    PubMed Central

    Quintão, Mônica; Chermont, Sérgio; Marchese, Luana; Brandão, Lúcia; Bernardez, Sabrina Pereira; Mesquita, Evandro Tinoco; Rocha, Nazareth de Novaes; Nóbrega, Antônio Claudio L.

    2014-01-01

    Background Patients with heart failure (HF) have left ventricular dysfunction and reduced mean arterial pressure (MAP). Increased adrenergic drive causes vasoconstriction and vessel resistance maintaining MAP, while increasing peripheral vascular resistance and conduit vessel stiffness. Increased pulse pressure (PP) reflects a complex interaction of the heart with the arterial and venous systems. Increased PP is an important risk marker in patients with chronic HF (CHF). Non-invasive ventilation (NIV) has been used for acute decompensated HF, to improve congestion and ventilation through both respiratory and hemodynamic effects. However, none of these studies have reported the effect of NIV on PP. Objective The objective of this study was to determine the acute effects of NIV with CPAP on PP in outpatients with CHF. Methods Following a double-blind, randomized, cross-over, and placebo-controlled protocol, twenty three patients with CHF (17 males; 60 ± 11 years; BMI 29 ± 5 kg/cm2, NYHA class II, III) underwent CPAP via nasal mask for 30 min in a recumbent position. Mask pressure was 6 cmH2O, whereas placebo was fixed at 0-1 cmH2O. PP and other non invasive hemodynamics variables were assessed before, during and after placebo and CPAP mode. Results CPAP decreased resting heart rate (Pre: 72 ± 9; vs. Post 5 min: 67 ± 10 bpm; p < 0.01) and MAP (CPAP: 87 ± 11; vs. control 96 ± 11 mmHg; p < 0.05 post 5 min). CPAP decreased PP (CPAP: 47 ± 20 pre to 38 ± 19 mmHg post; vs. control: 42 ± 12 mmHg, pre to 41 ± 18 post p < 0.05 post 5 min). Conclusion NIV with CPAP decreased pulse pressure in patients with stable CHF. Future clinical trials should investigate whether this effect is associated with improved clinical outcome. PMID:24676373

  17. Obesity and upper airway control during sleep

    PubMed Central

    Patil, Susheel P.; Squier, Samuel; Schneider, Hartmut; Kirkness, Jason P.; Smith, Philip L.

    2010-01-01

    Mechanisms linking obesity with upper airway dysfunction in obstructive sleep apnea are reviewed. Obstructive sleep apnea is due to alterations in upper airway anatomy and neuromuscular control. Upper airway structural alterations in obesity are related to adipose deposition around the pharynx, which can increase its collapsibility or critical pressure (Pcrit). In addition, obesity and, particularly, central adiposity lead to reductions in resting lung volume, resulting in loss of caudal traction on upper airway structures and parallel increases in pharyngeal collapsibility. Metabolic and humoral factors that promote central adiposity may contribute to these alterations in upper airway mechanical function and increase sleep apnea susceptibility. In contrast, neural responses to upper airway obstruction can mitigate these mechanical loads and restore pharyngeal patency during sleep. Current evidence suggests that these responses can improve with weight loss. Improvements in these neural responses with weight loss may be related to a decline in systemic and local pharyngeal concentrations of specific inflammatory mediators with somnogenic effects. PMID:19875707

  18. Airway obstruction in congenital central hypoventilation syndrome.

    PubMed

    Reverdin, Alexandra K; Mosquera, Ricardo; Colasurdo, Giuseppe N; Jon, Cindy K; Clements, Roya M

    2014-01-01

    Congenital central hypoventilation syndrome (CCHS) is the failure of the autonomic system to control adequate ventilation while asleep with preserved ventilatory response while awake. We report a case of a patient with CCHS who presented with intrathoracic and extrathoracic airway obstruction after tracheostomy tube decannulation and phrenic nerve pacer placement. Nocturnal polysomnography (NPSG) revealed hypoxia, hypercapnia and obstructive sleep apnoea, which required bilevel positive airway pressure titration. Airway endoscopy demonstrated tracheomalacia and paretic true vocal cords in the paramedian position during diaphragmatic pacing. Laryngeal electromyography demonstrated muscular electrical impulses that correlated with diaphragmatic pacer settings. Thus, we surmise that the patient's upper and lower airway obstruction was secondary to diaphragmatic pacer activity. Thorough airway evaluation, including NPSG and endoscopy, may help identify the side effects of diaphragmatic pacing, such as airway obstruction, in patients with CCHS.

  19. Dangerous Pressurization and Inappropriate Alarms during Water Occlusion of the Expiratory Circuit of Commonly Used Infant Ventilators

    PubMed Central

    Perdomo, Aldo

    2016-01-01

    Background Non-invasive continuous positive airways pressure is commonly a primary respiratory therapy delivered via multi-purpose ventilators in premature newborns. Expiratory limb occlusion due to water accumulation or ‘rainout’ from gas humidification is a frequent issue. A case of expiratory limb occlusion due to rainout causing unexpected and excessive repetitive airway pressurisation in a Draeger VN500 prompted a systematic bench test examination of currently available ventilators. Objective To assess neonatal ventilator response to partial or complete expiratory limb occlusion when set to non-invasive continuous positive airway pressure mode. Design Seven commercially available neonatal ventilators connected to a test lung using a standard infant humidifier circuit with partial and/or complete expiratory limb occlusion were examined in a bench test study. Each ventilator was set to deliver 6 cmH2O in non-invasive mode and respiratory mechanics data for 75%, 80% and 100% occlusion were collected. Results Several ventilators responded inappropriately with complete occlusion by cyclical pressurisation/depressurisation to peak pressures of between 19·4 and 64·6 cm H2O at rates varying between 2 to 77 inflations per minute. Tidal volumes varied between 10·1 and 24·3mL. Alarm responses varied from ‘specific’ (tube occluded) to ‘ambiguous’ (Safety valve open). Carefusion Avea responded by continuing to provide the set distending pressure and displaying an appropriate alarm message. Draeger Babylog 8000 did not alarm with partial occlusions and incorrectly displayed airways pressure at 6·1cmH2O compared to the measured values of 13cmH2O. Conclusions This study found a potential for significant adverse ventilator response due to complete or near complete expiratory limb occlusion in CPAP mode. PMID:27116224

  20. Puberty and Upper Airway Dynamics During Sleep

    PubMed Central

    Bandla, Preetam; Huang, Jingtao; Karamessinis, Laurie; Kelly, Andrea; Pepe, Michelle; Samuel, John; Brooks, Lee; Mason, Thornton. A.; Gallagher, Paul R.; Marcus, Carole L.

    2008-01-01

    Study Objectives: The upper airway compensatory response to subatmospheric pressure loading declines with age. The epidemiology of obstructive sleep apnea suggests that sex hormones play a role in modulating upper airway function. Sex hormones increase gradually during puberty, from minimally detectable to adult levels. We hypothesized that the upper airway response to subatmospheric pressure loading decreased with increasing pubertal Tanner stage in males but remained stable during puberty in females. Design: Upper airway dynamic function during sleep was measured over the course of puberty. Participants: Normal subjects of Tanner stages 1 to 5. Measurements: During sleep, maximal inspiratory airflow was measured while varying the level of nasal pressure. The slope of the upstream pressure-flow relationship (SPF) was measured. Results: The SPF correlated with age and Tanner stage. However, the relationship with Tanner stage became nonsignificant when the correlation due to the mutual association with age was removed. Females had a lower SPF than males. Conclusions: In both sexes, the upper airway compensatory response to subatmospheric pressure loading decreased with age rather than degree of pubertal development. Thus, changes in sex hormones are unlikely to be a primary modulator of upper airway function during the transition from childhood to adulthood. Although further studies of upper airway structural changes during puberty are needed, we speculate that the changes in upper airway function with age are due to the depressant effect of age on ventilatory drive, leading to a decrease in upper airway neuromotor tone. Citation: Bandla P; Huang J; Karamessinis L; Kelly A; Pepe M; Samuel J; Brooks L; Mason TA; Gallagher PR; Marcus CL. Puberty and Upper Airway Dynamics During Sleep. SLEEP 2008;31(4):534-541. PMID:18457241

  1. The Effects of Massage with Coconut and Sunflower Oils on Oxygen Saturation of Premature Infants with Respiratory Distress Syndrome Treated With Nasal Continuous Positive Airway Pressure

    PubMed Central

    Valizadeh, Sousan; Hosseini, Mohammad Bagher; Asghari Jafarabadi, Mohammad; Ajoodanian, Najmeh

    2012-01-01

    Introduction: Nowadays particular emphasis is placed on the developmental aspects of premature infants care. Massage therapy is one of the best-known methods of caring. Due to the minimal touch policy in neonatal intensive care units (NICUs), massaging is not usually performed on premature infants. However, there is not sufficient evidence to support the claim that newborn infants with complex medical conditions should not be massaged. This study aimed to determine the effects of massage with coconut and sunflower oils on oxygen saturation of infants with respiratory distress syndrome (RDS) treated with nasal continuous positive airway pressure (NCPAP). Methods: This was a randomized controlled trial on 90 newborns who were admitted to Alzahra Hospital (Tabriz, Iran). The infants were divided into control and massage therapy groups (massage with coconut and sunflower oils). Data was collected using a hospital documentation form. A 15-minute daily massage was performed for 3 days. Respiratory rate (RR), fraction of inspired oxygen (FiO2) and oxygen saturation were measured 5 minutes before the massage, 3 times during the massage, and 5 minutes after the massage. The collected data was analyzed using a mixed model. Results: In comparison to coconut oil and control groups, mean oxygen saturation of sunflower oil group was improved. In addition, the coconut massage group showed lower oxygen saturation than the control group but was all values were within the normal range. Although massage decreased oxygen saturation, there was no need to increase FiO2. Conclusion: Massage therapy can provide developmental care for infants treated with NCPAP. PMID:25276695

  2. Management of Neonatal Respiratory Distress Syndrome Employing ACoRN Respiratory Sequence Protocol versus Early Nasal Continuous Positive Airway Pressure Protocol

    PubMed Central

    Niknafs, Pedram; Faghani, Asadallah; Afjeh, Seyed-Abolfazl; Moradinazer, Mehdi; Bahman-Bijari, Bahareh

    2014-01-01

    Objective: Respiratory distress syndrome (RDS) is a common cause of respiratory distress in premature infants. This study was designed to evaluate two different RDS treatment protocols by comparing the outcomes. Methods: This study was a double center cross sectional study performed from June to December 2012. During that period, 386 neonates with RDS were hospitalized and treated according to two different therapeutic protocols so-called Acute Care of at-Risk Newborns (ACoRN) respiratory sequence protocol (group I) and Early Nasal Continuous Positive Airway Pressure (E-NCPAP) protocol (group II). The variables and main outcomes of this study were gestational age, birth weight, bronchopulmonary dysplasia (BPD), pulmonary hemorrhage (PH), intraventricular hemorrhage (IVH), air leak and mortality rate (MR). Findings : Out of 386 infants, 202 infants were in group I (male 60.4%, female 39.6%, mean gestational age 316/7 weeks, mean birth weight=1688 grams) and group II included 184 infants (male 61.4%, female 38.6%, mean gestational age 32 weeks, mean birth weight 1787 grams), P= 0.07. The ratios of BPD of group I to group II and PH of group I to group two were not significant (P=0.63 and P=0.84, respectively). Air leak ratio in group I was higher than in group II (P=0.001). Although IVH ratio in group II was higher than in group I (P=0.01), grade III and IV IVH was higher in group I (30% vs. 4.6%). In case of MR, it was higher in group I than in group II (P=0.001). Conclusion: According to the findings the incidence of air leak, grade III and IV IVH and MR was less common in E-NCPAP protocol, so it may show the effectiveness of this protocol. The authors suggest that more researches are needed for more accurate results. PMID:25793046

  3. Postoperative pharyngolaryngeal adverse events with laryngeal mask airway (LMA Supreme) in laparoscopic surgical procedures with cuff pressure limiting 25 cmH₂O: prospective, blind, and randomised study.

    PubMed

    Kang, Joo-Eun; Oh, Chung-Sik; Choi, Jae Won; Son, Il Soon; Kim, Seong-Hyop

    2014-01-01

    To reduce the incidence of postoperative pharyngolaryngeal adverse events, laryngeal mask airway (LMA) manufacturers recommend maximum cuff pressures not exceeding 60 cmH₂O. We performed a prospective randomised study, comparing efficacy and adverse events among patients undergoing laparoscopic surgical procedures who were allocated randomly into low (limiting 25 cmH₂O, L group) and high (at 60 cmH₂O, H group) LMA cuff pressure groups with LMA Supreme. Postoperative pharyngolaryngeal adverse events were evaluated at discharge from postanaesthetic care unit (PACU) (postoperative day 1, POD 1) and 24 hours after discharge from PACU (postoperative day 2, POD 2). All patients were well tolerated with LMA without ventilation failure. Before pneumoperitoneum, cuff volume and pressure and oropharyngeal leak pressure (OLP) showed significant differences. Postoperative sore throat at POD 2 (3 versus 12 patients) and postoperative dysphagia at POD 1 and POD 2 (0 versus 4 patients at POD 1; 0 versus 4 patients at POD 2) were significantly lower in L group, compared with H group. In conclusion, LMA with cuff pressure limiting 25 cmH₂O allowed both efficacy of airway management and lower incidence of postoperative adverse events in laparoscopic surgical procedures. This clinical trial is registered with KCT0000334.

  4. The role of upper airway stimulation therapy in the multidisciplinary management approach of obstructive sleep apnea in the adult patient.

    PubMed

    Doghramji, Karl; Boon, Maurits

    2016-09-01

    Upper airway stimulation therapy (UAS) is a novel and effective treatment modality for obstructive sleep apnea (OSA). It is indicated for patients who are intolerant to traditional forms of therapy such as CPAP, and who have moderate to severe disease. Its success also relies upon the absence of certain upper airway structural and functional abnormalities. Therefore, the implementation of UAS necessitates a comprehensive evaluation with the coordinated efforts of otolaryngologist and sleep specialist, utilizing the consultative input of various other specialists. This same collaborative process also underlies the successful long-term followup care of patients following implantation surgery. Laryngoscope, 126:S9-S11, 2016. PMID:27572121

  5. Upper airway function during maximal exercise in horses with obstructive upper airway lesions. Effect of surgical treatment.

    PubMed

    Williams, J W; Meagher, D M; Pascoe, J R; Hornof, W J

    1990-01-01

    Upper airway pressure was measured during maximal exercise in 10 Thoroughbred racehorses with naturally occurring upper airway obstruction. Left laryngeal hemiplegia and arytenoid chondropathy resulted in substantial increases (30-40 cm H2O) in inspiratory upper airway pressure (Pl), whereas complicated aryepiglottic entrapment and subepiglottic cysts produced only modest increases (15 cm H2O) in Pl. Uncomplicated aryepiglottic entrapment and grade IV pharyngeal lymphoid hyperplasia produced only slight increases (3-5 cm H2O). In general, surgical procedures restored airway pressures to within normal limits. Subtotal arytenoidectomy improved but did not normalize airway pressures in horses with arytenoid chondropathy. Pharyngeal lymphoid hyperplasia appeared to have little effect on upper airway function.

  6. Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial

    PubMed Central

    Mishra, Sandeep Kumar; Satyapraksh, M. V. S.; Bidkar, Prasanna Udupi; Hemavathy, Balachander

    2015-01-01

    Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis) and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was randomly changed from neutral to flexion, extension, and lateral rotation (left). The oropharyngeal leak pressures, fibreoptic view of glottis, ventilation scores, and delivered tidal volumes and end tidal CO2 were noted in all positions. Results. In both groups compared with neutral position, oropharyngeal leak pressures were significantly higher with flexion and lower with extension but similar with rotation of head and neck. However the oropharyngeal leak pressure was significantly higher for ProSeal LMA compared with the I-gel in all positions. Peak airway pressures were significantly higher with flexion in both groups (however this did not affect ventilation), lower with extension in ProSeal group, and comparable in I-gel group but did not change significantly with rotation of head and neck in both groups. Conclusion. Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA. PMID:25648620

  7. Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial.

    PubMed

    Mishra, Sandeep Kumar; Nawaz, Mohammad; Satyapraksh, M V S; Parida, Satyen; Bidkar, Prasanna Udupi; Hemavathy, Balachander; Kundra, Pankaj

    2015-01-01

    Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis) and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was randomly changed from neutral to flexion, extension, and lateral rotation (left). The oropharyngeal leak pressures, fibreoptic view of glottis, ventilation scores, and delivered tidal volumes and end tidal CO2 were noted in all positions. Results. In both groups compared with neutral position, oropharyngeal leak pressures were significantly higher with flexion and lower with extension but similar with rotation of head and neck. However the oropharyngeal leak pressure was significantly higher for ProSeal LMA compared with the I-gel in all positions. Peak airway pressures were significantly higher with flexion in both groups (however this did not affect ventilation), lower with extension in ProSeal group, and comparable in I-gel group but did not change significantly with rotation of head and neck in both groups. Conclusion. Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA.

  8. CEP120 and SPICE1 cooperate with CPAP in centriole elongation.

    PubMed

    Comartin, David; Gupta, Gagan D; Fussner, Eden; Coyaud, Étienne; Hasegan, Monica; Archinti, Marco; Cheung, Sally W T; Pinchev, Deborah; Lawo, Steffen; Raught, Brian; Bazett-Jones, David P; Lüders, Jens; Pelletier, Laurence

    2013-07-22

    Centrosomes organize microtubule (MT) arrays and are comprised of centrioles surrounded by ordered pericentriolar proteins. Centrioles are barrel-shaped structures composed of MTs, and as basal bodies they template the formation of cilia/flagella. Defects in centriole assembly can lead to ciliopathies and genome instability. The assembly of procentrioles requires a set of conserved proteins. It is initiated at the G1-to-S transition by PLK4 and CEP152, which help recruit SASS6 and STIL to the vicinity of the mother centriole to organize the cartwheel. Subsequently, CPAP promotes centriolar MT assembly and elongation in G2. While centriole integrity is maintained by CEP135 and POC1 through MT stabilization, centriole elongation requires POC5 and is restricted by CP110 and CEP97. How strict control of centriole length is achieved remains unclear. Here, we show that CEP120 and SPICE1 are required to localize CEP135 (but not SASS6, STIL, or CPAP) to procentrioles. CEP120 associates with SPICE1 and CPAP, and depletion of any of these proteins results in short procentrioles. Furthermore, CEP120 or CPAP overexpression results in excessive centriole elongation, a process dependent on CEP120, SPICE1, and CPAP. Our findings identify a shared function for these proteins in centriole length control.

  9. Initial Treatment of Respiratory Distress Syndrome with Nasal Intermittent Mandatory Ventilation versus Nasal Continuous Positive Airway Pressure: A Randomized Controlled Trial

    PubMed Central

    Armanian, Amir-Mohammad; Badiee, Zohreh; Heidari, Ghobad; Feizi, Awat; Salehimehr, Nima

    2014-01-01

    Background: Neonatal respiratory distress syndrome (RDS) in premature infants who survived and its complications are a common problem. Due to high morbidity and mechanical ventilation (MV) nowadays researchers in interested minimizing MV. To determine, in very low birth weight (BW) preterm neonates with RDS, if initial treatment with nasal intermittent mandatory ventilation (early NIMV) compared with early nasal continuous positive airway pressure (early NCPAP) obtains more favorable outcomes in terms of the duration of treatment, and the need for endotracheal tube ventilation. Methods: In this single-center randomized control trial study, infants (BW ≤ 1500 g and/or gestational age ≤ 34 weeks) with respiratory distress were considered eligible. Forty-four infants were randomly assigned to receive early-NIMV and 54 comparable infants to early-NCPAP. Surfactants were given, when FIO2 requirement was of >30%. Primary outcomes were failure of noninvasive respiratory support, that is, the need for MV in the first 48 h of life and for the duration of noninvasive respiratory support in each group. Results: 98 infants were enrolled (44 in the NIMV and 54 in the NCPAP group). The Preventive power of MV of NIMV usage (95.5%) was not lower than the NCPAP (98.1%) strength (hazard ratio: 0.21 (95% confidence interval: 0.02-2.66); P: 0.23). The duration of noninvasive respiratory support in the NIMV group was significantly shorter than NCPAP (the median (range) was 24 (18.00-48.00) h versus 48.00 (22.00-120.00) h in NIMV versus NCPAP groups; P < 0.001). Similarly, the duration of dependency on oxygen was less, for NIMV (the median (range) was 96.00 (41.00-504.00) h versus144.00 (70.00-1130.00) h in NIMV versus NCPAP groups; P: 0.009). Interestingly, time to full enteral feeds and length of hospital stay were more favorable in the NIMV versus the NCPAP group. Conclusions: Initial treatment of RDS with NIMV was safe, and well tolerated. Furthermore, NIMV had excellent

  10. Obesity hypoventilation syndrome (OHS)

    MedlinePlus

    Treatment involves breathing assistance using special machines (mechanical ventilation). Options include: Noninvasive mechanical ventilation such as continuous positive airway pressure (CPAP) or bilevel positive airway pressure (BiPAP) through a mask that ...

  11. Triggers of airway inflammation.

    PubMed

    Kerrebijn, K F

    1986-01-01

    Most asthmatics have hyperresponsive airways. This makes them more sensitive than non-asthmatics to bronchoconstricting environmental exposures which, in their turn, may enhance responsiveness. Airway inflammation is considered to be a key determinant of airway hyperresponsiveness: the fact that chronic airway inflammation in cystic fibrosis does not lead to airway hyperresponsiveness of any importance indicates, however, that the role of airway inflammation is complex and incompletely elucidated. The main inducers of airway inflammation are viral infections, antigens, occupational stimuli and pollutants. Although exercise, airway cooling and hyper- or hypotonic aerosols are potent stimuli of bronchoconstriction, it is questionable if airway inflammation is involved in their mode of action. Each of the above-mentioned stimuli is discussed, with emphasis laid on the relation of symptoms to mechanisms. PMID:3533597

  12. Surface tension of airway aspirates withdrawn during neonatal resuscitation reflects lung maturity.

    PubMed

    Stichtenoth, Guido; Walter, Gabi; Lange, Romy; Raith, Marco; Bernhard, Wolfgang; Herting, Egbert

    2014-08-01

    The indications for treatment of neonates with exogenous pulmonary surfactant are still discussed controversially. Some premature neonates are sufficiently treated by CPAP, others need conventional ventilation and/or surfactant. The available lung maturity tests have limitations. The captive bubble surfactometer (CBS) provides measurement of surface activity from rather small amounts of surfactant. This study aimed to determine surface activity from small volume aspirates of the upper airways of neonates by means of the CBS and to correlate the results with clinical data. Small upper airway aspirates from 159 neonates (gestational age 25-42 weeks) were withdrawn and concentrated 16.7-fold by ultracentrifugation and resuspension in saline. Surface activities after 5 min of adsorption were determined in the CBS and correlated to the perinatal data (e.g., gestational age, birth weight, gender), airway interventions (like CPAP, conventional ventilation) and surfactant treatment. Additionally, 27 samples were analyzed for surfactant specific phosphatidylcholine concentrations by using electrospray ionization tandem mass-spectroscopy. Surface activities show a significant correlation to gestational age, birth weight, and the need for airway interventions. Comparing the need for airway interventions versus surface activity, a receiver operating characteristic calculated a sensitivity of 0.77 and a specificity of 0.72 at a "cut off" of 44 mN/m. Surface activity correlates significantly with the phosphatidylcholine concentrations and the latter one correlates with the gestational age. Determination of surface activity from upper airway aspirates is feasible. Further clinical studies are needed to prove the predictive value of the method.

  13. Emergency airway puncture

    MedlinePlus

    Emergency airway puncture is the placement of a hollow needle through the throat into the airway. It ... efforts to assist with breathing have failed. A hollow needle or tube can be inserted into the ...

  14. Careers in Airway Science.

    ERIC Educational Resources Information Center

    Federal Aviation Administration (DOT), Washington, DC.

    The Federal Aviation Administration (FAA) has initiated the Airway Science curriculum as a method of preparing the next generation of aviation technicians and managers. This document: (1) discusses the FAA's role in the Airway Science program; (2) describes some of the career fields that FAA offers to Airway Science graduates (air traffic control…

  15. Obstructive Sleep Apnoea Syndrome, Endothelial Function and Markers of Endothelialization. Changes after CPAP

    PubMed Central

    Sanchez Armengol, Angeles; Moreno-Luna, Rafael; Caballero-Eraso, Candela; Macher, Hada C.; Villar, Jose; Merino, Ana M; Castell, Javier; Capote, Francisco; Stiefel, Pablo

    2015-01-01

    Study objectives This study tries to assess the endothelial function in vivo using flow-mediated dilatation (FMD) and several biomarkers of endothelium formation/restoration and damage in patients with obstructive sleep apnoea (OSA) syndrome at baseline and after three months with CPAP therapy. Design Observational study, before and after CPAP therapy. Setting and Patients We studied 30 patients with apnoea/hypopnoea index (AHI) >15/h that were compared with themselves after three months of CPAP therapy. FMD was assessed non-invasively in vivo using the Laser-Doppler flowmetry. Circulating cell-free DNA (cf-DNA) and microparticles (MPs) were measured as markers of endothelial damage and the vascular endothelial growth factor (VEGF) was determined as a marker of endothelial restoration process. Measurements and results After three month with CPAP, FMD significantly increased (1072.26 ± 483.21 vs. 1604.38 ± 915.69 PU, p< 0.005) cf-DNA and MPs significantly decreased (187.93 ± 115.81 vs. 121.28 ± 78.98 pg/ml, p<0.01, and 69.60 ± 62.60 vs. 39.82 ± 22.14 U/μL, p<0.05, respectively) and VEGF levels increased (585.02 ± 246.06 vs. 641.11 ± 212.69 pg/ml, p<0.05). These changes were higher in patients with more severe disease. There was a relationship between markers of damage (r = -0.53, p<0.005) but not between markers of damage and restoration, thus suggesting that both types of markers should be measured together. Conclusions CPAP therapy improves FMD. This improvement may be related to an increase of endothelial restoration process and a decrease of endothelial damage. PMID:25815511

  16. The emergency airway.

    PubMed

    Goon, Serena S H; Stephens, Robert C M; Smith, Helen

    2009-12-01

    The 'can't intubate, can't ventilate' scenario is a nightmare for all clinicians who manage airways. Cricothyroidotomy is one of several emergency airway management techniques. Cricothyroidotomy is a short-term solution which provides oxygenation, not ventilation, and is not a definitive airway. Although there are tests which can help predict whether an intubation will be difficult, they are not always good predictors. As the can't intubate, can't ventilate scenario is rare, cricothyroidotomy is an unfamiliar procedure to many. In this situation, expert help must be called for early on. In the meantime, it is vital that all other simple airway manoeuvres have been attempted, such as good positioning of the patient with head tilt and chin lift, and use of airway adjuncts like the oral (Guedel) airway or nasopharyngeal airway, and the laryngeal mask airway. However, if attempts to secure the airway are unsuccessful, there may be no other option than to perform a cricothyroidotomy. It is a difficult decision to make, but with increasing hypoxia, it is essential that one oxygenates the patient. Cricothyroidotomy provides an opening in the pace between the anterior inferior border of the thyroid cartilage and the anterior superior border of the cricoid cartilage, allowing access to the airway below the glottis. The anatomical considerations are important when performing this procedure (Ellis, 2009), and there are other scenarios when it is used. It is not without consequence, as with any procedure.

  17. Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases

    PubMed Central

    Wieczorek, Andrzej; Gaszynski, Tomasz

    2015-01-01

    Introduction There are some patients with severe respiratory disturbances like adult respiratory distress syndrome (ARDS) and suspicion of brain death, for whom typical performance of the apneic test is difficult to complete because of quick desaturation and rapid deterioration without effective ventilation. To avoid failure of brain death confirmation and possible loss of organ donation another approach to apneic test is needed. We present two cases of patients with clinical symptoms of brain death, with lung pathology (acute lung injury, ARDS, lung embolism and lung infection), in whom apneic tests for recognizing brain death were difficult to perform. During typical performance of apneic test involving the use of oxygen catheter for apneic oxygenation we observed severe desaturation with growing hypotension and hemodynamic destabilization. But with the use of Boussignac CPAP system all necessary tests were successfully completed, confirming the patient’s brain death, which gave us the opportunity to perform procedures for organ donation. The main reason of apneic test difficulties was severe gas exchange disturbances secondary to ARDS. Thus lack of positive end expiratory pressure during classical performance of apneic test leads to quick desaturation and rapid hemodynamic deterioration, limiting the observation period below dedicated at least 10-minute interval. Conclusion The Boussignac CPAP system may be an effective tool for performing transparent apneic test in case of serious respiratory disturbances, especially in the form of acute lung injury or ARDS. PMID:26124664

  18. Engineering Airway Epithelium

    PubMed Central

    Soleas, John P.; Paz, Ana; Marcus, Paula; McGuigan, Alison; Waddell, Thomas K.

    2012-01-01

    Airway epithelium is constantly presented with injurious signals, yet under healthy circumstances, the epithelium maintains its innate immune barrier and mucociliary elevator function. This suggests that airway epithelium has regenerative potential (I. R. Telford and C. F. Bridgman, 1990). In practice, however, airway regeneration is problematic because of slow turnover and dedifferentiation of epithelium thereby hindering regeneration and increasing time necessary for full maturation and function. Based on the anatomy and biology of the airway epithelium, a variety of tissue engineering tools available could be utilized to overcome the barriers currently seen in airway epithelial generation. This paper describes the structure, function, and repair mechanisms in native epithelium and highlights specific and manipulatable tissue engineering signals that could be of great use in the creation of artificial airway epithelium. PMID:22523471

  19. Comparative assessment of several automatic CPAP devices' responses: a bench test study

    PubMed Central

    Isetta, Valentina; Navajas, Daniel; Montserrat, Josep M.

    2015-01-01

    Automatic continuous positive airway pressure (APAP) devices adjust the delivered pressure based on the breathing patterns of the patient and, accordingly, they may be more suitable for patients who have a variety of pressure demands during sleep based on factors such as body posture, sleep stage or variability between nights. Devices from different manufacturers incorporate distinct algorithms and may therefore respond differently when subjected to the same disturbed breathing pattern. Our objective was to assess the response of several currently available APAP devices in a bench test. A computer-controlled model mimicking the breathing pattern of a patient with obstructive sleep apnoea (OSA) was connected to different APAP devices for 2-h tests during which flow and pressure readings were recorded. Devices tested were AirSense 10 (ResMed), Dreamstar (Sefam), Icon (Fisher & Paykel), Resmart (BMC), Somnobalance (Weinmann), System One (Respironics) and XT-Auto (Apex). Each device was tested twice. The response of each device was considerably different. Whereas some devices were able to normalise breathing, in some cases exceeding the required pressure, other devices did not eliminate disturbed breathing events (mainly prolonged flow limitation). Mean and maximum pressures ranged 7.3–14.6 cmH2O and 10.4–17.9 cmH2O, respectively, and the time to reach maximum pressure varied from 4.4 to 96.0 min. Each APAP device uses a proprietary algorithm and, therefore, the response to a bench simulation of OSA varied significantly. This must be taken into account for nasal pressure treatment of OSA patients and when comparing results from clinical trials. PMID:27730142

  20. Dynamics of Surfactant Liquid Plugs at Bifurcating Lung Airway Models

    NASA Astrophysics Data System (ADS)

    Tavana, Hossein

    2013-11-01

    A surfactant liquid plug forms in the trachea during surfactant replacement therapy (SRT) of premature babies. Under air pressure, the plug propagates downstream and continuously divides into smaller daughter plugs at continuously branching lung airways. Propagating plugs deposit a thin film on airway walls to reduce surface tension and facilitate breathing. The effectiveness of SRT greatly depends on the final distribution of instilled surfactant within airways. To understand this process, we investigate dynamics of splitting of surfactant plugs in engineered bifurcating airway models. A liquid plug is instilled in the parent tube to propagate and split at the bifurcation. A split ratio, R, is defined as the ratio of daughter plug lengths in the top and bottom daughter airway tubes and studied as a function of the 3D orientation of airways and different flow conditions. For a given Capillary number (Ca), orienting airways farther away from a horizontal position reduced R due to the flow of a larger volume into the gravitationally favored daughter airway. At each orientation, R increased with 0.0005 < Ca < 0.05. This effect diminished by decrease in airways diameter. This approach will help elucidate surfactant distribution in airways and develop effective SRT strategies.

  1. Modeling Upper Airway Collapse by a Finite Element Model with Regional Tissue Properties

    PubMed Central

    Xu, Chun; Brennick, Michael J.; Dougherty, Lawrence; Wootton, David M.

    2009-01-01

    This study presents a new computational system for modeling the upper airway in rats that combines tagged magnetic resonance imaging (MRI) with tissue material properties to predict three-dimensional (3D) airway motion. The model is capable of predicting airway wall and tissue deformation under airway pressure loading up to airway collapse. The model demonstrates that oropharynx collapse pressure depends primarily on ventral wall (tongue muscle) elastic modulus and airway architecture. An iterative approach that involves substituting alternative possible tissue elastic moduli was used to improve model precision. The proposed 3D model accounts for stress-strain relationships in the complex upper airway that should present new opportunities for understanding pathogenesis of airway collapse, improving diagnosis and developing treatments. PMID:19747871

  2. Mechanical Properties of the Upper Airway

    PubMed Central

    Strohl, Kingman P.; Butler, James P.; Malhotra, Atul

    2013-01-01

    The importance of the upper airway (nose, pharynx, and larynx) in health and in the pathogenesis of sleep apnea, asthma, and other airway diseases, discussed elsewhere in the Comprehensive Physiology series, prompts this review of the biomechanical properties and functional aspects of the upper airway. There is a literature based on anatomic or structural descriptions in static circumstances, albeit studied in limited numbers of individuals in both health and disease. As for dynamic features, the literature is limited to studies of pressure and flow through all or parts of the upper airway and to the effects of muscle activation on such features; however, the links between structure and function through airway size, shape, and compliance remain a topic that is completely open for investigation, particularly through analyses using concepts of fluid and structural mechanics. Throughout are included both historically seminal references, as well as those serving as signposts or updated reviews. This article should be considered a resource for concepts needed for the application of biomechanical models of upper airway physiology, applicable to understanding the pathophysiology of disease and anticipated results of treatment interventions. PMID:23723026

  3. Elective use of the Ventrain for upper airway obstruction during high-frequency jet ventilation.

    PubMed

    Fearnley, Robert A; Badiger, Sheela; Oakley, Richard J; Ahmad, Imran

    2016-09-01

    The safety of high pressure source ventilation (jet ventilation) is dependent upon upper airway patency to facilitate adequate passive expiration and prevent increasing intrathoracic pressure and its associated deleterious sequelae. Distortions in airway anatomy may make passive expiration inadequate or impossible in some patients. We report the elective use of the Ventrain device to provide ventilation in a clinical setting of upper airway obstruction in a patient with post radiation fibrosis that had previously prevented passive expiration during attempted high pressure source ventilation.

  4. Controversies in Pediatric Perioperative Airways

    PubMed Central

    Klučka, Jozef; Štourač, Petr; Štoudek, Roman; Ťoukálková, Michaela; Harazim, Hana; Kosinová, Martina

    2015-01-01

    Pediatric airway management is a challenge in routine anesthesia practice. Any airway-related complication due to improper procedure can have catastrophic consequences in pediatric patients. The authors reviewed the current relevant literature using the following data bases: Google Scholar, PubMed, Medline (OVID SP), and Dynamed, and the following keywords: Airway/s, Children, Pediatric, Difficult Airways, and Controversies. From a summary of the data, we identified several controversies: difficult airway prediction, difficult airway management, cuffed versus uncuffed endotracheal tubes for securing pediatric airways, rapid sequence induction (RSI), laryngeal mask versus endotracheal tube, and extubation timing. The data show that pediatric anesthesia practice in perioperative airway management is currently lacking the strong evidence-based medicine (EBM) data that is available for adult subpopulations. A number of procedural steps in airway management are derived only from adult populations. However, the objective is the same irrespective of patient age: proper securing of the airway and oxygenation of the patient. PMID:26759809

  5. Nasal Airway Resistance: Its Measurement and Regulation.

    ERIC Educational Resources Information Center

    Hamilton, Lyle H.

    1979-01-01

    Reviews studies of regulation of nasal airway resistance (Rn). Describes methods of calculating Rn by measuring pressure-flow relationship. Data are presented on improved methods for measuring Rn and effects for expiratory and inspiratory Rn after topical application of phenylephrine nasal decongestant spray. (Author/SA)

  6. Management of the difficult airway.

    PubMed

    Strauss, Robert A; Noordhoek, Roseanna

    2010-03-01

    The oral and maxillofacial surgeon frequently encounters and manages difficult airways. Knowledge of and calm progression by practitioner and staff through different means to ventilate and manage a difficult airway are crucial. Practitioners should become comfortable with different types of alternative or rescue airways in order to intervene quickly in case of emergent or unanticipated airway compromise.

  7. Compliance Measurements of the Upper Airway in Pediatric Down Syndrome Sleep Apnea Patients.

    PubMed

    Subramaniam, Dhananjay Radhakrishnan; Mylavarapu, Goutham; McConnell, Keith; Fleck, Robert J; Shott, Sally R; Amin, Raouf S; Gutmark, Ephraim J

    2016-04-01

    Compliance of soft tissue and muscle supporting the upper airway are two of several factors contributing to pharyngeal airway collapse. We present a novel, minimally invasive method of estimating regional variations in pharyngeal elasticity. Magnetic resonance images for pediatric sleep apnea patients with Down syndrome [9.5 ± 4.3 years (mean age ± standard deviation)] were analyzed to segment airways corresponding to baseline (no mask pressure) and two positive pressures. A three dimensional map was created to evaluate axial and circumferential variation in radial displacements of the airway, dilated by the positive pressures. The displacements were then normalized with respect to the appropriate transmural pressure and radius of an equivalent circle to obtain a measure of airway compliance. The resulting elasticity maps indicated the least and most compliant regions of the pharynx. Airway stiffness of the most compliant region [403 ± 204 (mean ± standard deviation) Pa] decreased with severity of obstructive sleep apnea. The non-linear response of the airway wall to continuous positive airway pressure was patient specific and varied between anatomical locations. We identified two distinct elasticity phenotypes. Patient phenotyping based on airway elasticity can potentially assist clinical practitioners in decision making on the treatments needed to improve airway patency.

  8. Centrobin-mediated regulation of the centrosomal protein 4.1-associated protein (CPAP) level limits centriole length during elongation stage.

    PubMed

    Gudi, Radhika; Haycraft, Courtney J; Bell, P Darwin; Li, Zihai; Vasu, Chenthamarakshan

    2015-03-13

    Microtubule-based centrioles in the centrosome mediate accurate bipolar cell division, spindle orientation, and primary cilia formation. Cellular checkpoints ensure that the centrioles duplicate only once in every cell cycle and achieve precise dimensions, dysregulation of which results in genetic instability and neuro- and ciliopathies. The normal cellular level of centrosomal protein 4.1-associated protein (CPAP), achieved by its degradation at mitosis, is considered as one of the major mechanisms that limits centriole growth at a predetermined length. Here we show that CPAP levels and centriole elongation are regulated by centrobin. Exogenous expression of centrobin causes abnormal elongation of centrioles due to massive accumulation of CPAP in the cell. Conversely, CPAP was undetectable in centrobin-depleted cells, suggesting that it undergoes degradation in the absence of centrobin. Only the reintroduction of full-length centrobin, but not its mutant form that lacks the CPAP binding site, could restore cellular CPAP levels in centrobin-depleted cells, indicating that persistence of CPAP requires its interaction with centrobin. Interestingly, inhibition of the proteasome in centrobin-depleted cells restored the cellular and centriolar CPAP expression, suggesting its ubiquitination and proteasome-mediated degradation when centrobin is absent. Intriguingly, however, centrobin-overexpressing cells also showed proteasome-independent accumulation of ubiquitinated CPAP and abnormal, ubiquitin-positive, elongated centrioles. Overall, our results show that centrobin interacts with ubiquitinated CPAP and prevents its degradation for normal centriole elongation function. Therefore, it appears that loss of centrobin expression destabilizes CPAP and triggers its degradation to restrict the centriole length during biogenesis.

  9. Patterns of recruitment and injury in a heterogeneous airway network model.

    PubMed

    Stewart, Peter S; Jensen, Oliver E

    2015-10-01

    In respiratory distress, lung airways become flooded with liquid and may collapse due to surface-tension forces acting on air-liquid interfaces, inhibiting gas exchange. This paper proposes a mathematical multiscale model for the mechanical ventilation of a network of occluded airways, where air is forced into the network at a fixed tidal volume, allowing investigation of optimal recruitment strategies. The temporal response is derived from mechanistic models of individual airway reopening, incorporating feedback on the airway pressure due to recruitment. The model accounts for stochastic variability in airway diameter and stiffness across and between generations. For weak heterogeneity, the network is completely ventilated via one or more avalanches of recruitment (with airways recruited in quick succession), each characterized by a transient decrease in the airway pressure; avalanches become more erratic for airways that are initially more flooded. However, the time taken for complete ventilation of the network increases significantly as the network becomes more heterogeneous, leading to increased stresses on airway walls. The model predicts that the most peripheral airways are most at risk of ventilation-induced damage. A positive-end-expiratory pressure reduces the total recruitment time but at the cost of larger stresses exerted on airway walls. PMID:26423440

  10. Airway management in trauma.

    PubMed

    Langeron, O; Birenbaum, A; Amour, J

    2009-05-01

    Maintenance of a patent and prevention of aspiration are essential for the management of the trauma patient, that requires experienced physicians in airway control techniques. Difficulties of the airway control in the trauma setting are increased by the vital failures, the risk of aspiration, the potential cervical spine injury, the combative patient, and the obvious risk of difficult tracheal intubation related to specific injury related to the trauma. Endotracheal intubation remains the gold standard in trauma patient airway management and should be performed via the oral route with a rapid sequence induction and a manual in-line stabilization maneuver, to decrease the risks previously mentioned. Different techniques to control the airway in trauma patients are presented: improvement of the laryngoscopic vision, lighted stylet tracheal intubation, retrograde technique for orotracheal intubation, the laryngeal mask and the intubating laryngeal mask airways, the combitube and cricothyroidotomy. Management of the airway in trauma patients requires regular training in these techniques and the knowledge of complementary techniques allowing tracheal intubation or oxygenation to overcome difficult intubation and to prevent major complications as hypoxemia and aspiration. PMID:19412149

  11. Role of upper airway ultrasound in airway management.

    PubMed

    Osman, Adi; Sum, Kok Meng

    2016-01-01

    Upper airway ultrasound is a valuable, non-invasive, simple, and portable point of care ultrasound (POCUS) for evaluation of airway management even in anatomy distorted by pathology or trauma. Ultrasound enables us to identify important sonoanatomy of the upper airway such as thyroid cartilage, epiglottis, cricoid cartilage, cricothyroid membrane, tracheal cartilages, and esophagus. Understanding this applied sonoanatomy facilitates clinician to use ultrasound in assessment of airway anatomy for difficult intubation, ETT and LMA placement and depth, assessment of airway size, ultrasound-guided invasive procedures such as percutaneous needle cricothyroidotomy and tracheostomy, prediction of postextubation stridor and left double-lumen bronchial tube size, and detecting upper airway pathologies. Widespread POCUS awareness, better technological advancements, portability, and availability of ultrasound in most critical areas facilitate upper airway ultrasound to become the potential first-line non-invasive airway assessment tool in the future. PMID:27529028

  12. Role of upper airway ultrasound in airway management.

    PubMed

    Osman, Adi; Sum, Kok Meng

    2016-01-01

    Upper airway ultrasound is a valuable, non-invasive, simple, and portable point of care ultrasound (POCUS) for evaluation of airway management even in anatomy distorted by pathology or trauma. Ultrasound enables us to identify important sonoanatomy of the upper airway such as thyroid cartilage, epiglottis, cricoid cartilage, cricothyroid membrane, tracheal cartilages, and esophagus. Understanding this applied sonoanatomy facilitates clinician to use ultrasound in assessment of airway anatomy for difficult intubation, ETT and LMA placement and depth, assessment of airway size, ultrasound-guided invasive procedures such as percutaneous needle cricothyroidotomy and tracheostomy, prediction of postextubation stridor and left double-lumen bronchial tube size, and detecting upper airway pathologies. Widespread POCUS awareness, better technological advancements, portability, and availability of ultrasound in most critical areas facilitate upper airway ultrasound to become the potential first-line non-invasive airway assessment tool in the future.

  13. Indirect airway challenges.

    PubMed

    Joos, G F; O'Connor, B; Anderson, S D; Chung, F; Cockcroft, D W; Dahlén, B; DiMaria, G; Foresi, A; Hargreave, F E; Holgate, S T; Inman, M; Lötvall, J; Magnussen, H; Polosa, R; Postma, D S; Riedler, J

    2003-06-01

    Indirect challenges act by causing the release of endogenous mediators that cause the airway smooth muscle to contract. This is in contrast to the direct challenges where agonists such as methacholine or histamine cause airflow limitation predominantly via a direct effect on airway smooth muscle. Direct airway challenges have been used widely and are well standardised. They are highly sensitive, but not specific to asthma and can be used to exclude current asthma in a clinic population. Indirect bronchial stimuli, in particular exercise, hyperventilation, hypertonic aerosols, as well as adenosine, may reflect more directly the ongoing airway inflammation and are therefore more specific to identify active asthma. They are increasingly used to evaluate the prevalence of bronchial hyperresponsiveness and to assess specific problems in patients with known asthma, e.g. exercise-induced bronchoconstriction, evaluation before scuba diving. Direct bronchial responsiveness is only slowly and to a modest extent, influenced by repeated administration of inhaled steroids. Indirect challenges may reflect more closely acute changes in airway inflammation and a change in responsiveness to an indirect stimulus may be a clinically relevant marker to assess the clinical course of asthma. Moreover, some of the indirect challenges, e.g. hypertonic saline and mannitol, can be combined with the assessment of inflammatory cells by induction of sputum.

  14. Molecular basis for CPAP-tubulin interaction in controlling centriolar and ciliary length

    PubMed Central

    Zheng, Xiangdong; Ramani, Anand; Soni, Komal; Gottardo, Marco; Zheng, Shuangping; Ming Gooi, Li; Li, Wenjing; Feng, Shan; Mariappan, Aruljothi; Wason, Arpit; Widlund, Per; Pozniakovsky, Andrei; Poser, Ina; Deng, Haiteng; Ou, Guangshuo; Riparbelli, Maria; Giuliano, Callaini; Hyman, Anthony A.; Sattler, Michael; Gopalakrishnan, Jay; Li, Haitao

    2016-01-01

    Centrioles and cilia are microtubule-based structures, whose precise formation requires controlled cytoplasmic tubulin incorporation. How cytoplasmic tubulin is recognized for centriolar/ciliary-microtubule construction remains poorly understood. Centrosomal-P4.1-associated-protein (CPAP) binds tubulin via its PN2-3 domain. Here, we show that a C-terminal loop-helix in PN2-3 targets β-tubulin at the microtubule outer surface, while an N-terminal helical motif caps microtubule's α-β surface of β-tubulin. Through this, PN2-3 forms a high-affinity complex with GTP-tubulin, crucial for defining numbers and lengths of centriolar/ciliary-microtubules. Surprisingly, two distinct mutations in PN2-3 exhibit opposite effects on centriolar/ciliary-microtubule lengths. CPAPF375A, with strongly reduced tubulin interaction, causes shorter centrioles and cilia exhibiting doublet- instead of triplet-microtubules. CPAPEE343RR that unmasks the β-tubulin polymerization surface displays slightly reduced tubulin-binding affinity inducing over-elongation of newly forming centriolar/ciliary-microtubules by enhanced dynamic release of its bound tubulin. Thus CPAP regulates delivery of its bound-tubulin to define the size of microtubule-based cellular structures using a ‘clutch-like' mechanism. PMID:27306797

  15. Airway statuses and nasopharyngeal airway use for airway obstruction in syndromic craniosynostosis.

    PubMed

    Kouga, Takeshi; Tanoue, Koji; Matsui, Kiyoshi

    2014-05-01

    Syndromic craniosynostosis is associated with a high rate of respiratory difficulty, due mainly to midfacial hypoplasia. Nasopharyngeal airway establishment has been reported as the first-line approach to airway obstruction and may obviate the need for a highly invasive tracheotomy. No previous studies have compared airway obstruction status in syndromic craniosynostosis between cases requiring and not requiring airway managements. We focus on nasopharyngeal airway use and airway status outcomes to assess respiratory difficulty in patients with syndromic craniosynostosis. A retrospective data analysis of 51 cases with syndromic craniosynostosis was carried out. We divided 30 of the 51 cases with lateral pharyngeal x-rays taken before operations affecting airway diameters into 2 groups, one with neither nasopharyngeal airway insertion nor tracheotomy and the other with one or both of these interventions, and the mean diameters for 8 indices related to the pharyngeal space were compared. Cases with respiratory difficulty due to nasopharyngeal stenosis and requiring airway managements comprised a significantly higher proportion of those with Pfeiffer syndrome than patients with Crouzon or Apert syndrome. Comparative examination of lateral x-ray cephalometry between cases with neither nasopharyngeal airway insertion nor tracheotomy and cases with one or both revealed oropharyngeal diameters tended to be smaller in those with interventions. Cases requiring nasopharyngeal airway insertion were able to continue nasopharyngeal airway use for more than 1 year and a considerable number avoided tracheotomy. It may be worth considering an oropharyngeal-bypass nasopharyngeal airway before performing a tracheotomy. PMID:24820706

  16. Vascular Anomalies and Airway Concerns

    PubMed Central

    Clarke, Caroline; Lee, Edward I.; Edmonds, Joseph

    2014-01-01

    Vascular anomalies, both tumors and malformations, can occur anywhere in the body, including the airway, often without any external manifestations. However, vascular anomalies involving the airway deserve special consideration as proper recognition and management can be lifesaving. In this article, the authors discuss vascular anomalies as they pertains to the airway, focusing on proper diagnosis, diagnostic modalities, and therapeutic options. PMID:25045336

  17. A theoretical analysis of the effect of airway smooth muscle load on airway narrowing.

    PubMed

    Macklem, P T

    1996-01-01

    We used published data for the elastic properties of a 2-mm outer-diameter canine bronchus and assumed values for the thickness of the wall components and lung parenchymal shear modulus to estimate the load on airway smooth muscle and its effect on airway narrowing. The following relationships were calculated: (1) luminal and smooth muscle radii of curvature and transmural pressure; (2) the isovolume, transmural pressures developed by the smooth muscle to narrow the lumen at distending pressures of 20, 10, 5, and 2 cm H2O; (3) the equilibrium tension developed by, and thus the load on, the airway smooth muscle as a function of smooth muscle length during isovolume bronchoconstriction. From these calculations a smooth muscle length-tension diagram was drawn allowing the interactions between submucosal thickening, peribronchial thickening, load, and smooth muscle contractility to be analyzed. The analysis indicates that: (1) the load on smooth muscle decreases by more than an order of magnitude between a distending pressure of 20 and 2 cm H2O; (2) increasing smooth muscle contractility has more effect at large rather than at small distending pressures; (3) peribronchial inflammation decreases both load and the slope of the relationship between peribronchial and pleural pressures. Decreases in load may be an important mechanism producing excessive bronchoconstriction in asthma. PMID:8542167

  18. [Usefulness of the basic exploration of the upper airways and neighbor structures in patients with adult obstructive sleep apnea-hypopnea syndrome].

    PubMed

    Ferré, Alex; Vila, Javier; Arcalís, Núria

    2014-04-01

    Obstructive sleep apnea-hypopnea syndrome (OSAHS) is a prevalent disease in the general population, associated with an increase in the cardiovascular morbimortality. A basic and/or standardized otolaryngologic exploration could help us to detect the structural abnormalities that alter the upper airway collapsibility and offer a high pre-test risk factor, improve the CPAP adherence or even the possibility of offering alternative treatments. This article offers a revision of the exploration in OSAHS patients. We describe a guideline to identify the main structural abnormalities related to OSAHS. We also include a short algorithm for the diagnosis of OSAHS, when is suspected by primary care physicians.

  19. Crystal structures of the CPAP/STIL complex reveal its role in centriole assembly and human microcephaly.

    PubMed

    Cottee, Matthew A; Muschalik, Nadine; Wong, Yao Liang; Johnson, Christopher M; Johnson, Steven; Andreeva, Antonina; Oegema, Karen; Lea, Susan M; Raff, Jordan W; van Breugel, Mark

    2013-09-17

    Centrioles organise centrosomes and template cilia and flagella. Several centriole and centrosome proteins have been linked to microcephaly (MCPH), a neuro-developmental disease associated with small brain size. CPAP (MCPH6) and STIL (MCPH7) are required for centriole assembly, but it is unclear how mutations in them lead to microcephaly. We show that the TCP domain of CPAP constitutes a novel proline recognition domain that forms a 1:1 complex with a short, highly conserved target motif in STIL. Crystal structures of this complex reveal an unusual, all-β structure adopted by the TCP domain and explain how a microcephaly mutation in CPAP compromises complex formation. Through point mutations, we demonstrate that complex formation is essential for centriole duplication in vivo. Our studies provide the first structural insight into how the malfunction of centriole proteins results in human disease and also reveal that the CPAP-STIL interaction constitutes a conserved key step in centriole biogenesis. DOI:http://dx.doi.org/10.7554/eLife.01071.001.

  20. Indication of CPAP in Patients with Suspected Obstructive Sleep Apnea, Based on Clinical Parameters and a Novel Two-Channel Recording Device (ApneaLink): A Pilot Study

    PubMed Central

    Nigro, Carlos Alberto; Dibur, Eduardo; Grandval, Sofía; Nogueira, Facundo

    2012-01-01

    Objective. To evaluate the accuracy and reliability of the medical decision based on the results of the hand scoring from a two-channel recording device (ApneaLink) plus clinical data for the prescription of a CPAP assay in patients with suspected OSA. Methods. 39 subjects were assessed in the sleep laboratory with polysomnography and ApneaLink. The patients completed the Epworth sleepiness scale and a clinical history. Two blinded independent observers decided to prescribe CPAP according to the results of the PSG (gold standard, observer A), ApneaLink (alternative method, observer B), and the clinical parameters. Sensitivity and specificity of observer B on the indication of CPAP were calculated. The interobserver agreement for the indication of CPAP was assessed using kappa statistics. Results. 38 subjects were included (26 men, mean age 47.5, mean RDI 28.7, mean BMI 31.4 kg/m2). The prevalence of OSA was 84%. The sensitivity and specificity of observer B to initiate a CPAP trial were 90.6% and 100%, respectively. The interrater agreement for the prescription of CPAP was good (kappa: 0.75). Conclusion. This study has shown that the use of ApneaLink plus clinical data has made it possible to indicate CPAP reliably in most patients with high-clinical pretest for OSA. PMID:23470904

  1. A multicentre, randomised controlled, non-inferiority trial, comparing high flow therapy with nasal continuous positive airway pressure as primary support for preterm infants with respiratory distress (the HIPSTER trial): study protocol

    PubMed Central

    Roberts, Calum T; Owen, Louise S; Manley, Brett J; Donath, Susan M; Davis, Peter G

    2015-01-01

    Introduction High flow (HF) therapy is an increasingly popular mode of non-invasive respiratory support for preterm infants. While there is now evidence to support the use of HF to reduce extubation failure, there have been no appropriately designed and powered studies to assess the use of HF as primary respiratory support soon after birth. Our hypothesis is that HF is non-inferior to the standard treatment—nasal continuous positive airway pressure (NCPAP)— as primary respiratory support for preterm infants. Methods and analysis The HIPSTER trial is an unblinded, international, multicentre, randomised, non-inferiority trial. Eligible infants are preterm infants of 28–36+6 weeks’ gestational age (GA) who require primary non-invasive respiratory support for respiratory distress in the first 24 h of life. Infants are randomised to treatment with either HF or NCPAP. The primary outcome is treatment failure within 72 h after randomisation, as determined by objective oxygenation, blood gas, and apnoea criteria, or the need for urgent intubation and mechanical ventilation. Secondary outcomes include the incidence of intubation, pneumothorax, bronchopulmonary dysplasia, nasal trauma, costs associated with hospital care and parental stress. With a specified non-inferiority margin of 10%, using a two-sided 95% CI and 90% power, the study requires 375 infants per group (total 750 infants). Ethics and dissemination Ethical approval has been granted by the relevant human research ethics committees at The Royal Women's Hospital (13/12), The Royal Children's Hospital (33144A), The Mercy Hospital for Women (R13/34), and the South-Eastern Norway Regional Health Authority (2013/1657). The trial is currently recruiting at 9 centres in Australia and Norway. The trial results will be published in peer-reviewed international journals, and presented at national and international conferences. Trial registration number Australian New Zealand Clinical Trials Registry ID: ACTRN

  2. Effects of pentobarbital on upper airway patency during sleep

    PubMed Central

    Eikermann, M.; Eckert, D.J.; Chamberlin, N.L.; Jordan, A.S.; Zaremba, S.; Smith, S.; Rosow, C.; Malhotra, A.

    2012-01-01

    We hypothesised that pentobarbital would improve upper airway mechanics based on an increase in latency to arousal and amplitude of the phasic genioglossus electromyogram (EMG), and a decrease in the active upper airway critical closing pressure (Pcrit). 12 healthy subjects received pentobarbital (100 mg) or placebo in a double-blind, crossover protocol. During wakefulness, we measured the genioglossus reflex response to negative pressure pulses. During sleep, carbon dioxide was insufflated into the inspired air. Airway pressure was then decreased in a stepwise fashion until arousal from sleep. With basal breathing during sleep: flow rate was lower in volunteers given pentobarbital; end-tidal CO2 concentration and upper airway resistance were greater; and Pcrit was unaffected (pentobarbital mean±sd -11.7±4.5 versus placebo -10.25±3.6 cmH2O; p=0.11). Pentobarbital increased the time to arousal (297±63s versus 232±67 s; p<0.05), at which time phasic genioglossus EMG was higher (6.2±4.8% maximal versus 3.1±3%; p<0.05) as were CO2 levels. The increase in genioglossus EMG after CO2 administration was greater after pentobarbital versus placebo. Pentobarbital did not affect the genioglossus negative-pressure reflex. Pentobarbital increases the time to arousal and stimulates genioglossus muscle activity, but it also increases upper airway resistance during sleep. PMID:20032012

  3. Effects of pentobarbital on upper airway patency during sleep.

    PubMed

    Eikermann, M; Eckert, D J; Chamberlin, N L; Jordan, A S; Zaremba, S; Smith, S; Rosow, C; Malhotra, A

    2010-09-01

    We hypothesised that pentobarbital would improve upper airway mechanics based on an increase in latency to arousal and amplitude of the phasic genioglossus electromyogram (EMG), and a decrease in the active upper airway critical closing pressure (P(crit)). 12 healthy subjects received pentobarbital (100 mg) or placebo in a double-blind, crossover protocol. During wakefulness, we measured the genioglossus reflex response to negative pressure pulses. During sleep, carbon dioxide was insufflated into the inspired air. Airway pressure was then decreased in a stepwise fashion until arousal from sleep. With basal breathing during sleep: flow rate was lower in volunteers given pentobarbital; end-tidal CO(2) concentration and upper airway resistance were greater; and P(crit) was unaffected (pentobarbital mean ± SD -11.7 ± 4.5 versus placebo -10.25 ± 3.6 cmH(2)O; p = 0.11). Pentobarbital increased the time to arousal (297 ± 63s versus 232 ± 67 s; p<0.05), at which time phasic genioglossus EMG was higher (6.2 ± 4.8% maximal versus 3.1 ± 3%; p<0.05) as were CO(2) levels. The increase in genioglossus EMG after CO(2) administration was greater after pentobarbital versus placebo. Pentobarbital did not affect the genioglossus negative-pressure reflex. Pentobarbital increases the time to arousal and stimulates genioglossus muscle activity, but it also increases upper airway resistance during sleep.

  4. Contribution of airway closure to chronic postbronchiolitis airway dysfunction in rats.

    PubMed

    Sorkness, Ronald L; Tuffaha, Amjad

    2004-03-01

    Genetically susceptible Brown Norway rats develop a chronic asthmalike syndrome after recovering from viral bronchiolitis at an early age. We hypothesized that airway closure is an important mechanism of airflow obstruction in postbronchiolitis rats. Rats were studied 8-12 wk after inoculation with Sendai virus or sterile vehicle at 3-4 wk of age. Under light pentobarbital anesthesia, rats were instrumented with an orotracheal catheter and an esophageal pressure monitor and placed in a total body plethysmograph. Lung volumes and forced-expiratory maneuvers were measured using the Boyle's law method and software-controlled valving of positive and negative pressures to elicit lung inflations and rapid deflations; pulmonary resistance was measured during spontaneous tidal breathing; and quasi-static pressure-volume curves were obtained with passive inflations and deflations in fully anesthetized, paralyzed rats. Compared with controls, the postbronchiolitis rats had elevated pulmonary resistance and reduced forced-expiratory volume in 0.2 s. Most of the reduced forced-expiratory volume in 0.2 s was associated with reduced forced vital capacity, indicating premature airway closure as a prominent mechanism. The reduced airflow in postbronchiolitis rats was highly dependent on lung volume, being nearly normal at 70% lung capacity, but sevenfold less than normal at 30% lung capacity. Increased respiratory system hysteresis between functional reserve capacity and total lung capacity was evidence for increased airway closure at normal end-expiratory lung volumes in postbronchiolitis rats. We conclude that airway instability and closure is a prominent mechanism of the chronic airway dysfunction in rats that have recovered from viral bronchiolitis at an early age. PMID:14594863

  5. Conserved TCP domain of Sas-4/CPAP is essential for pericentriolar material tethering during centrosome biogenesis.

    PubMed

    Zheng, Xiangdong; Gooi, Li Ming; Wason, Arpit; Gabriel, Elke; Mehrjardi, Narges Zare; Yang, Qian; Zhang, Xingrun; Debec, Alain; Basiri, Marcus L; Avidor-Reiss, Tomer; Pozniakovsky, Andrei; Poser, Ina; Saric, Tomo; Hyman, Anthony A; Li, Haitao; Gopalakrishnan, Jay

    2014-01-21

    Pericentriolar material (PCM) recruitment to centrioles forms a key step in centrosome biogenesis. Deregulation of this process leads to centrosome aberrations causing disorders, one of which is autosomal recessive primary microcephaly (MCPH), a neurodevelopmental disorder where brain size is reduced. During PCM recruitment, the conserved centrosomal protein Sas-4/CPAP/MCPH6, known to play a role in centriole formation, acts as a scaffold for cytoplasmic PCM complexes to bind and then tethers them to centrioles to form functional centrosomes. To understand Sas-4's tethering role, we determined the crystal structure of its T complex protein 10 (TCP) domain displaying a solvent-exposed single-layer of β-sheets fold. This unique feature of the TCP domain suggests that it could provide an "extended surface-like" platform to tether the Sas-4-PCM scaffold to a centriole. Functional studies in Drosophila, human cells, and human induced pluripotent stem cell-derived neural progenitor cells were used to test this hypothesis, where point mutations within the 9-10th β-strands (β9-10 mutants including a MCPH-associated mutation) perturbed PCM tethering while allowing Sas-4/CPAP to scaffold cytoplasmic PCM complexes. Specifically, the Sas-4 β9-10 mutants displayed perturbed interactions with Ana2, a centrosome duplication factor, and Bld-10, a centriole microtubule-binding protein, suggesting a role for the β9-10 surface in mediating protein-protein interactions for efficient Sas-4-PCM scaffold centriole tethering. Hence, we provide possible insights into how centrosomal protein defects result in human MCPH and how Sas-4 proteins act as a vehicle to tether PCM complexes to centrioles independent of its well-known role in centriole duplication.

  6. The Tulip GT® airway versus the facemask and Guedel airway: a randomised, controlled, cross-over study by Basic Life Support-trained airway providers in anaesthetised patients.

    PubMed

    Shaikh, A; Robinson, P N; Hasan, M

    2016-03-01

    We performed a randomised, controlled, cross-over study of lung ventilation by Basic Life Support-trained providers using either the Tulip GT® airway or a facemask with a Guedel airway in 60 anaesthetised patients. Successful ventilation was achieved if the provider produced an end-tidal CO2 > 3.5 kPa and a tidal volume > 250 ml in two of the first three breaths, within 60 sec and within two attempts. Fifty-seven (95%) providers achieved successful ventilation using the Tulip GT compared with 35 (58%) using the facemask (p < 0.0001). Comparing the Tulip GT and facemask, the mean (SD) end-tidal CO2 was 5.0 (0.7) kPa vs 2.5 (1.5) kPa, tidal volume was 494 (175) ml vs 286 (186) ml and peak inspiratory pressure was 18.3 (3.4) cmH2 O vs 13.6 (7) cmH2 O respectively (all p < 0.0001). Forty-seven (78%) users favoured the Tulip GT airway. These results are similar to a previous manikin study using the same protocol, suggesting a close correlation between human and manikin studies for this airway device. We conclude that the Tulip GT should be considered as an adjunct to airway management both within and outside hospitals when ventilation is being undertaken by Basic Life Support-trained airway providers. PMID:26684684

  7. The Tulip GT® airway versus the facemask and Guedel airway: a randomised, controlled, cross-over study by Basic Life Support-trained airway providers in anaesthetised patients.

    PubMed

    Shaikh, A; Robinson, P N; Hasan, M

    2016-03-01

    We performed a randomised, controlled, cross-over study of lung ventilation by Basic Life Support-trained providers using either the Tulip GT® airway or a facemask with a Guedel airway in 60 anaesthetised patients. Successful ventilation was achieved if the provider produced an end-tidal CO2 > 3.5 kPa and a tidal volume > 250 ml in two of the first three breaths, within 60 sec and within two attempts. Fifty-seven (95%) providers achieved successful ventilation using the Tulip GT compared with 35 (58%) using the facemask (p < 0.0001). Comparing the Tulip GT and facemask, the mean (SD) end-tidal CO2 was 5.0 (0.7) kPa vs 2.5 (1.5) kPa, tidal volume was 494 (175) ml vs 286 (186) ml and peak inspiratory pressure was 18.3 (3.4) cmH2 O vs 13.6 (7) cmH2 O respectively (all p < 0.0001). Forty-seven (78%) users favoured the Tulip GT airway. These results are similar to a previous manikin study using the same protocol, suggesting a close correlation between human and manikin studies for this airway device. We conclude that the Tulip GT should be considered as an adjunct to airway management both within and outside hospitals when ventilation is being undertaken by Basic Life Support-trained airway providers.

  8. Air-Q intubating laryngeal airway: A study of the second generation supraglottic airway device

    PubMed Central

    Attarde, Viren Bhaskar; Kotekar, Nalini; Shetty, Sarika M

    2016-01-01

    Background and Aims: Air-Q intubating laryngeal mask airway (ILA) is used as a supraglottic airway device and as a conduit for endotracheal intubation. This study aims to assess the efficacy of the Air-Q ILA regarding ease of insertion, adequacy of ventilation, rate of successful intubation, haemodynamic response and airway morbidity. Methods: Sixty patients presenting for elective surgery at our Medical College Hospital were selected. Following adequate premedication, baseline vital parameters, pulse rate and blood pressure were recorded. Air-Q size 3.5 for patients 50-70 kg and size 4.5 for 70-100 kg was selected. After achieving adequate intubating conditions, Air-Q ILA was introduced. Confirming adequate ventilation, appropriate sized endotracheal tube was advanced through the Air-Q blindly to intubate the trachea. Placement of the endotracheal tube in trachea was confirmed. Results: Air-Q ILA was successfully inserted in 88.3% of patients in first attempt and 11.7% patients in second attempt. Ventilation was adequate in 100% of patients. Intubation was successful in 76.7% of patients with Air-Q ILA. 23.3% of patients were intubated by direct laryngoscopy following failure with two attempts using Air-Q ILA. Post-intubation the change in heart rate was statistically significant (P < 0.0001). 10% of patients were noted to have a sore throat and 5% of patients had mild airway trauma. Conclusion: Air-Q ILA is a reliable device as a supraglottic airway ensuring adequate ventilation as well as a conduit for endotracheal intubation. It benefits the patient by avoiding the stress of direct laryngoscopy and is also superior alternative device for use in a difficult airway. PMID:27212722

  9. Managing upper airway obstruction.

    PubMed

    Innes, M H

    A complete respiratory obstruction can lead to death in 3 minutes. The first and constant duty of the nurse aider is to check that the person is breathing by looking, listening and feeling. Partial obstruction is no less serious than complete obstruction. The nurse aider, in any situation, should assess the problem and attempt to overcome the airway obstruction using the measures described. PMID:1490067

  10. Airway gene therapy.

    PubMed

    Davies, Jane C; Alton, Eric W F W

    2005-01-01

    Given both the accessibility and the genetic basis of several pulmonary diseases, the lungs and airways initially seemed ideal candidates for gene therapy. Several routes of access are available, many of which have been refined and optimized for nongene drug delivery. Two respiratory diseases, cystic fibrosis (CF) and alpha1-antitrypsin (alpha1-AT) deficiency, are relatively common; the single gene responsible has been identified and current treatment strategies are not curative. This type of inherited disease was the obvious initial target for gene therapy, but it has become clear that nongenetic and acquired diseases, including cancer, may also be amenable to this approach. The majority of preclinical and clinical studies in the airway have involved viral vectors, although for diseases such as CF, likely to require repeated application, non-viral delivery systems have clear advantages. However, with both approaches a range of barriers to gene expression have been identified that are limiting success in the airway and alveolar region. This chapter reviews these issues, strategies aimed at overcoming them, and progress into clinical trials with non-viral vectors in a variety of pulmonary diseases.

  11. Use of the i-gel™ supraglottic airway device in a patient with subglottic stenosis -a case report-.

    PubMed

    Lee, Ki Hwa; Kang, Eun Su; Jung, Jae Wook; Park, Jae Hong; Choi, Young Gyun

    2013-09-01

    The airway management of patients with subglottic stenosis poses many challenges for the anesthesiologists. Many anesthesiologists use a narrow endotracheal tube for airway control. This, however, can lead to complications such as tracheal mucosal trauma, tracheal perforation or bleeding. The ASA difficult airway algorithm recommends the use of supraglottic airway devices in a failed intubation/ventilation scenario. In this report, we present a case of failed intubation in a patient with subglottic stenosis successfully managed during an i-gel™ supraglottic airway device. The device provided a good seal, and allowed for controlled mechanical ventilation with acceptable peak pressures while the patient was in the beach-chair position.

  12. Comparison of i-gel supraglottic airway and LMA-ProSeal™ in pediatric patients under controlled ventilation

    PubMed Central

    Saran, Sai; Mishra, Sandeep Kumar; Badhe, Ashok Shankar; Vasudevan, Arumugam; Elakkumanan, Lenin Babu; Mishra, Gayatri

    2014-01-01

    Background: i-gel™ and the ProSeal™ laryngeal mask airway (PLMA) are two supraglottic airway devices with gastric channel used for airway maintenance in anesthesia. This study was designed to evaluate the efficacy of i-gel compared with PLMA for airway maintenance in pediatric patients under general anesthesia with controlled ventilation. Materials and Methods: A total of 60 American Society of Anesthesiologists physical status 1 and 2 patients were included in the study and randomized to either i-gel or PLMA group. After induction of anesthesia using a standardized protocol for all the patients, one of supraglottic airway devices was inserted. Insertion parameters, ease of gastric tube insertion and fiber-optic scoring of the glottis were noted. Airway parameters such as end-tidal carbon dioxide (EtCO2), peak airway pressures and leak airway pressures were noted. Patients were observed for any complications in the first 12 h of the post-operative period. Results: Both groups were comparable in terms of ease of insertion, number of attempts and other insertion parameters. Ease of gastric tube insertion, EtCO2, airway pressures (peak and leak airway pressure) and fiber-optic view of the glottis were comparable in both groups. There were no clinically significant complications in the first 12 h of the post-operative period. Conclusion: i-gel is as effective as PLMA in pediatric patients under controlled ventilation. PMID:24803756

  13. Elective use of the Ventrain for upper airway obstruction during high-frequency jet ventilation.

    PubMed

    Fearnley, Robert A; Badiger, Sheela; Oakley, Richard J; Ahmad, Imran

    2016-09-01

    The safety of high pressure source ventilation (jet ventilation) is dependent upon upper airway patency to facilitate adequate passive expiration and prevent increasing intrathoracic pressure and its associated deleterious sequelae. Distortions in airway anatomy may make passive expiration inadequate or impossible in some patients. We report the elective use of the Ventrain device to provide ventilation in a clinical setting of upper airway obstruction in a patient with post radiation fibrosis that had previously prevented passive expiration during attempted high pressure source ventilation. PMID:27555171

  14. Assessment of methacholine-induced airway constriction by ultrafast high-resolution computed tomography.

    PubMed

    Amirav, I; Kramer, S S; Grunstein, M M; Hoffman, E A

    1993-11-01

    Assessment of changes in airway dimensions during bronchoconstriction is conventionally based on measurements of respiratory mechanics. We evaluated the efficacy of ultrafast high-resolution computed tomography (UHRCT) to directly determine the dynamic changes in cross-sectional area (CSA) of airways in response to methacholine (MCh). UHRCT scans were obtained at functional residual capacity before (baseline) and after intravenous bolus injections of MCh (10(-8.5)-10(-7.0) mol/kg) to seven mechanically ventilated pigs. Changes in CSA of bronchi of varying baseline size (1-10 mm diam) were determined by using a customized image processing software package (VIDA) based on a user-directed computer-adjusted edge-finding algorithm. MCh induced dose-dependent decreases in CSA, which were paralleled by increases in airway opening pressure at higher doses of MCh; at lower doses of MCh, decreases in CSA of smaller airways were detected without concomitant changes in airway opening pressure. Changes in CSA were heterogeneous and variable, especially in the smaller airway ranges. The results of the present study support the concept that UHRCT can be used in conjunction with bolus challenges to effectively determine dose-response changes in airway caliber in both large and small airways. This technique provides data that may not be reflected by conventional lung function measurements and, hence, is a useful tool to study airway reactivity.

  15. Reflex modulation of airflow dynamics through the upper airway.

    PubMed

    Seelagy, M M; Schwartz, A R; Russ, D B; King, E D; Wise, R A; Smith, P L

    1994-06-01

    We studied the effect of respiratory reflexes on maximal inspiratory flow (VImax) and its mechanical determinants, pharyngeal critical pressure (Pcrit) and nasal resistance, in an isolated feline upper airway preparation. Chemoreceptor reflexes were evaluated by varying inspired oxygen and end-tidal CO2 concentrations. At each gas concentration, we found that changes in VImax were related to changes in Pcrit. As CO2 increased, Pcrit became increasingly subatmospheric (P < 0.02), indicating reductions in pharyngeal collapsibility. In contrast, progressive hypoxia had no effect on Pcrit. We then examined the effects of vagal afferents and upper airway mucosal receptors on airflow dynamics at three levels of CO2. We confirmed that CO2 increased VImax (P < 0.01) and decreased Pcrit to more subatmospheric levels (P < 0.05) in both the presence and absence of vagal and airway mucosal afferent activity. Moreover, airway mucosal afferents led to smaller reductions in Pcrit (a less collapsible airway) (P < 0.05), whereas vagal afferents led to a larger increase in Pcrit (a more collapsible pharynx) under hypercapnic conditions (P < 0.01). We conclude that CO2 had a major effect on pharyngeal collapsability and that its effect was modulated by vagal and mucosal afferents. We speculate that the sensitivity and threshold to reflex CO2 responses play a major role in the maintenance of airway patency.

  16. Computed Tomography-Guided Tissue Engineering of Upper Airway Cartilage

    PubMed Central

    Brown, Bryan N.; Siebenlist, Nicholas J.; Cheetham, Jonathan; Ducharme, Norm G.; Rawlinson, Jeremy J.

    2014-01-01

    Normal laryngeal function has a large impact on quality of life, and dysfunction can be life threatening. In general, airway obstructions arise from a reduction in neuromuscular function or a decrease in mechanical stiffness of the structures of the upper airway. These reductions decrease the ability of the airway to resist inspiratory or expiratory pressures, causing laryngeal collapse. We propose to restore airway patency through methods that replace damaged tissue and improve the stiffness of airway structures. A number of recent studies have utilized image-guided approaches to create cell-seeded constructs that reproduce the shape and size of the tissue of interest with high geometric fidelity. The objective of the present study was to establish a tissue engineering approach to the creation of viable constructs that approximate the shape and size of equine airway structures, in particular the epiglottis. Computed tomography images were used to create three-dimensional computer models of the cartilaginous structures of the larynx. Anatomically shaped injection molds were created from the three-dimensional models and were seeded with bovine auricular chondrocytes that were suspended within alginate before static culture. Constructs were then cultured for approximately 4 weeks post-seeding and evaluated for biochemical content, biomechanical properties, and histologic architecture. Results showed that the three-dimensional molded constructs had the approximate size and shape of the equine epiglottis and that it is possible to seed such constructs while maintaining 75%+ cell viability. Extracellular matrix content was observed to increase with time in culture and was accompanied by an increase in the mechanical stiffness of the construct. If successful, such an approach may represent a significant improvement on the currently available treatments for damaged airway cartilage and may provide clinical options for replacement of damaged tissue during treatment of

  17. Global airway disease beyond allergy.

    PubMed

    Hellings, Peter W; Prokopakis, Emmanuel P

    2010-03-01

    Besides the anatomic continuity of the upper and lower airways, inflammation in one part of the airway influences the homeostasis of the other. The mechanisms underlying this interaction have been studied primarily in allergic disease, showing systemic immune activation, induction of inflammation at a distance, and a negative impact of nasal inflammation on bronchial homeostasis. In addition to allergy, other inflammatory conditions of the upper airways are associated with lower airway disease. Rhinosinusitis is frequently associated with asthma and chronic obstructive pulmonary disease. The impairment of purification, humidification, and warming up of the inspired air by the nose in rhinosinusitis may be responsible in part for bronchial pathology. The resolution of sinonasal inflammation via medical and/or surgical treatment is responsible for the beneficial effect of the treatment on bronchial disease. This article provides a comprehensive overview of the current knowledge of upper and lower airway communication beyond allergic disease.

  18. The mechanics of airway closure.

    PubMed

    Heil, Matthias; Hazel, Andrew L; Smith, Jaclyn A

    2008-11-30

    We describe how surface-tension-driven instabilities of the lung's liquid lining may lead to pulmonary airway closure via the formation of liquid bridges that occlude the airway lumen. Using simple theoretical models, we demonstrate that this process may occur via a purely fluid-mechanical "film collapse" or through a coupled, fluid-elastic "compliant collapse" mechanism. Both mechanisms can lead to airway closure in times comparable with the breathing cycle, suggesting that surface tension is the primary mechanical effect responsible for the closure observed in peripheral regions of the human lungs. We conclude by discussing the influence of additional effects not included in the simple models, such as gravity, the presence of pulmonary surfactant, respiratory flow and wall motion, the airways' geometry, and the mechanical structure of the airway walls. PMID:18595784

  19. Operative endoscopy of the airway

    PubMed Central

    Walters, Dustin M.

    2016-01-01

    Airway endoscopy has long been an important and useful tool in the management of thoracic diseases. As thoracic specialists have gained experience with both flexible and rigid bronchoscopic techniques, the technology has continued to evolve so that bronchoscopy is currently the foundation for diagnosis and treatment of many thoracic ailments. Airway endoscopy plays a significant role in the biopsy of tumors within the airways, mediastinum, and lung parenchyma. Endoscopic methods have been developed to treat benign and malignant airway stenoses and tracheomalacia. And more recently, techniques have been conceived to treat end-stage emphysema and prolonged air leaks in select patients. This review describes the abundant uses of airway endoscopy, as well as technical considerations and limitations of the current technologies. PMID:26981263

  20. Using optical coherence tomography (OCT) imaging in the evaluation of airway dynamics (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Szabari, Margit V.; Kelly, Vanessa J.; Applegate, Matthew B.; Chee, Chunmin; Tan, Khay M.; Hariri, Lida P.; Harris, R. Scott; Winkler, Tilo; Suter, Melissa J.

    2016-03-01

    Asthma is a chronic disease resulting in periodic attacks of coughing and wheezing due to temporarily constricted and clogged airways. The pathophysiology of asthma and the process of airway narrowing are not completely understood. Appropriate in vivo imaging modality with sufficient spatial and temporal resolution to dynamically assess the behavior of airways is missing. Optical coherence tomography (OCT) enables real-time evaluation of the airways during dynamic and static breathing maneuvers. Our aim was to visualize the structure and function of airways in healthy and Methacholine (MCh) challenged lung. Sheep (n=3) were anesthetized, mechanically ventilated and imaged with OCT in 4 dependent and 4 independent airways both pre- and post-MCh administration. The OCT system employed a 2.4 Fr (0.8 mm diameter) catheter and acquired circumferential cross-sectional images in excess of 100 frames per second during dynamic tidal breathing, 20 second static breath-holds at end-inspiration and expiration pressure, and in a response to a single deep inhalation. Markedly different airway behavior was found in dependent versus non-dependent airway segments before and after MCh injection. OCT is a non-ionizing light-based imaging modality, which may provide valuable insight into the complex dynamic behavior of airway structure and function in the normal and asthmatic lung.

  1. Measuring Upper and Lower Airway Resistance During Sleep with the Forced Oscillation Technique

    PubMed Central

    Campana, Lisa M.; Owens, R. L.; Suki, B.; Malhotra, A.

    2012-01-01

    The forced oscillation technique (FOT) is a non-invasive technique to monitor airway obstruction in those with asthma. The aim of this study was to design and validate a system to use FOT during sleep, both with and without bi-level positive airway pressure (BPAP), and to separate upper airway resistance from lower. 8 Hz pressure oscillations were supplied, over which the subject breathed, pressure and flow measurements were then used to calculate impedance. A phase-shift induced by the pressure transducer tubing was characterized, and FOT resistance was compared to steady flow resistance both with and without BPAP. A Millar catheter was used to measure pressure at the epiglottis, allowing the separation of upper from lower airway resistance. A phase shift of −0.010 s was calculated for the pressure transducer tubing, and the average error between FOT and steady flow resistance was −0.2 ± 0.2 cmH2O/L/s without BPAP and 0.4 ± 0.2 cmH2O/L/s with BPAP. The system was tested on three subjects, one healthy, one with obstructive sleep apnea, and one with asthma. The FOT was well tolerated and resistance was separated into upper and lower airway components. This setup is suitable for monitoring both upper and lower airway obstruction during sleep in those with and without asthma. PMID:22127514

  2. Computational analysis of microbubble flows in bifurcating airways: role of gravity, inertia, and surface tension.

    PubMed

    Chen, Xiaodong; Zielinski, Rachel; Ghadiali, Samir N

    2014-10-01

    Although mechanical ventilation is a life-saving therapy for patients with severe lung disorders, the microbubble flows generated during ventilation generate hydrodynamic stresses, including pressure and shear stress gradients, which damage the pulmonary epithelium. In this study, we used computational fluid dynamics to investigate how gravity, inertia, and surface tension influence both microbubble flow patterns in bifurcating airways and the magnitude/distribution of hydrodynamic stresses on the airway wall. Direct interface tracking and finite element techniques were used to simulate bubble propagation in a two-dimensional (2D) liquid-filled bifurcating airway. Computational solutions of the full incompressible Navier-Stokes equation were used to investigate how inertia, gravity, and surface tension forces as characterized by the Reynolds (Re), Bond (Bo), and Capillary (Ca) numbers influence pressure and shear stress gradients at the airway wall. Gravity had a significant impact on flow patterns and hydrodynamic stress magnitudes where Bo > 1 led to dramatic changes in bubble shape and increased pressure and shear stress gradients in the upper daughter airway. Interestingly, increased pressure gradients near the bifurcation point (i.e., carina) were only elevated during asymmetric bubble splitting. Although changes in pressure gradient magnitudes were generally more sensitive to Ca, under large Re conditions, both Re and Ca significantly altered the pressure gradient magnitude. We conclude that inertia, gravity, and surface tension can all have a significant impact on microbubble flow patterns and hydrodynamic stresses in bifurcating airways.

  3. Relationship between upper airway obstruction and gastroesophageal reflux in a dog model.

    PubMed

    Boesch, Richard Paul; Shah, Prashant; Vaynblat, Mikhail; Marcus, Michael; Pagala, Murali; Narwal, Shivinder; Kazachkov, Mikhail

    2005-01-01

    The association between gastroesophageal reflux (GER) and upper airway obstruction in children is recognized but not well understood. Our objective was to determine if the creation of a model of upper airway obstruction in dogs would cause GER and to determine if the GER is related to intrathoracic pressure changes. Five dogs underwent evaluation with esophageal manometry and pH probe at baseline and 1 week after creation of an upper airway obstruction. Airway obstruction was created by placement of a fenestrated cuffed tracheostomy tube, which was then capped and the cuff was inflated, requiring the animals to breathe via the fenestrations. The negative inspiratory pressure (Pes) (+/- SD) increased from 11.8 +/- 4.8 cm H(2)O at baseline to 17.6 +/- 4.9 cm H(2)O 1 week after creation of an airway obstruction (p = .029). None of the dogs had GER at baseline with a reflux index (RI) value of 0.0; however, 1 week after creation of airway obstruction, three out of five dogs had GER, with a mean RI value of 21.2 +/- 21.2. There was a significant (p = .023) correlation (r = .928) of the changes in Pes and RI values following airway obstruction. Upper airway obstruction (UAO) does cause GER in this canine model. Severity of GER is significantly correlated with Pes changes. PMID:16249167

  4. Increased airway glucose increases airway bacterial load in hyperglycaemia.

    PubMed

    Gill, Simren K; Hui, Kailyn; Farne, Hugo; Garnett, James P; Baines, Deborah L; Moore, Luke S P; Holmes, Alison H; Filloux, Alain; Tregoning, John S

    2016-01-01

    Diabetes is associated with increased frequency of hospitalization due to bacterial lung infection. We hypothesize that increased airway glucose caused by hyperglycaemia leads to increased bacterial loads. In critical care patients, we observed that respiratory tract bacterial colonisation is significantly more likely when blood glucose is high. We engineered mutants in genes affecting glucose uptake and metabolism (oprB, gltK, gtrS and glk) in Pseudomonas aeruginosa, strain PAO1. These mutants displayed attenuated growth in minimal medium supplemented with glucose as the sole carbon source. The effect of glucose on growth in vivo was tested using streptozocin-induced, hyperglycaemic mice, which have significantly greater airway glucose. Bacterial burden in hyperglycaemic animals was greater than control animals when infected with wild type but not mutant PAO1. Metformin pre-treatment of hyperglycaemic animals reduced both airway glucose and bacterial load. These data support airway glucose as a critical determinant of increased bacterial load during diabetes. PMID:27273266

  5. Increased airway glucose increases airway bacterial load in hyperglycaemia

    PubMed Central

    Gill, Simren K.; Hui, Kailyn; Farne, Hugo; Garnett, James P.; Baines, Deborah L.; Moore, Luke S.P.; Holmes, Alison H.; Filloux, Alain; Tregoning, John S.

    2016-01-01

    Diabetes is associated with increased frequency of hospitalization due to bacterial lung infection. We hypothesize that increased airway glucose caused by hyperglycaemia leads to increased bacterial loads. In critical care patients, we observed that respiratory tract bacterial colonisation is significantly more likely when blood glucose is high. We engineered mutants in genes affecting glucose uptake and metabolism (oprB, gltK, gtrS and glk) in Pseudomonas aeruginosa, strain PAO1. These mutants displayed attenuated growth in minimal medium supplemented with glucose as the sole carbon source. The effect of glucose on growth in vivo was tested using streptozocin-induced, hyperglycaemic mice, which have significantly greater airway glucose. Bacterial burden in hyperglycaemic animals was greater than control animals when infected with wild type but not mutant PAO1. Metformin pre-treatment of hyperglycaemic animals reduced both airway glucose and bacterial load. These data support airway glucose as a critical determinant of increased bacterial load during diabetes. PMID:27273266

  6. Computational Flow Modeling of Human Upper Airway Breathing

    NASA Astrophysics Data System (ADS)

    Mylavarapu, Goutham

    Computational modeling of biological systems have gained a lot of interest in biomedical research, in the recent past. This thesis focuses on the application of computational simulations to study airflow dynamics in human upper respiratory tract. With advancements in medical imaging, patient specific geometries of anatomically accurate respiratory tracts can now be reconstructed from Magnetic Resonance Images (MRI) or Computed Tomography (CT) scans, with better and accurate details than traditional cadaver cast models. Computational studies using these individualized geometrical models have advantages of non-invasiveness, ease, minimum patient interaction, improved accuracy over experimental and clinical studies. Numerical simulations can provide detailed flow fields including velocities, flow rates, airway wall pressure, shear stresses, turbulence in an airway. Interpretation of these physical quantities will enable to develop efficient treatment procedures, medical devices, targeted drug delivery etc. The hypothesis for this research is that computational modeling can predict the outcomes of a surgical intervention or a treatment plan prior to its application and will guide the physician in providing better treatment to the patients. In the current work, three different computational approaches Computational Fluid Dynamics (CFD), Flow-Structure Interaction (FSI) and Particle Flow simulations were used to investigate flow in airway geometries. CFD approach assumes airway wall as rigid, and relatively easy to simulate, compared to the more challenging FSI approach, where interactions of airway wall deformations with flow are also accounted. The CFD methodology using different turbulence models is validated against experimental measurements in an airway phantom. Two case-studies using CFD, to quantify a pre and post-operative airway and another, to perform virtual surgery to determine the best possible surgery in a constricted airway is demonstrated. The unsteady

  7. Respiratory failure due to expiratory central airway collapse.

    PubMed

    Murgu, Septimiu D; Cherrison, Lawrence J; Colt, Henri G

    2007-06-01

    We report a patient with respiratory failure due to expiratory central airway collapse successfully treated with airway stents. A 74-year-old male with obesity and obstructive sleep apnea had recurrent episodes of acute respiratory failure. Noninvasive positive-pressure ventilation failed because of patient intolerance and lack of improvement, and soon after he stopped using the noninvasive ventilator he developed severe respiratory failure that required a tracheostomy. He was transferred to our institution one month later. Fiberoptic bronchoscopy revealed diffuse expiratory central airway collapse of both main bronchi and the lower two thirds of the trachea, caused by bulging of the posterior airway membrane. During rigid bronchoscopy we inserted studded silicone stents in the right and left mainstem bronchi and in the distal trachea. The patient was weaned from mechanical ventilation 72 hours later and discharged to a long-term care facility. Expiratory central airway collapse should be considered in the differential diagnosis of patients with respiratory failure, especially when weaning from mechanical ventilation is difficult. PMID:17521465

  8. Apoptosis and the Airway Epithelium

    PubMed Central

    White, Steven R.

    2011-01-01

    The airway epithelium functions as a barrier and front line of host defense in the lung. Apoptosis or programmed cell death can be elicited in the epithelium as a response to viral infection, exposure to allergen or to environmental toxins, or to drugs. While apoptosis can be induced via activation of death receptors on the cell surface or by disruption of mitochondrial polarity, epithelial cells compared to inflammatory cells are more resistant to apoptotic stimuli. This paper focuses on the response of airway epithelium to apoptosis in the normal state, apoptosis as a potential regulator of the number and types of epithelial cells in the airway, and the contribution of epithelial cell apoptosis in important airways diseases. PMID:22203854

  9. Extraglottic airway devices: A review

    PubMed Central

    Ramaiah, Ramesh; Das, Debasmita; Bhananker, Sanjay M; Joffe, Aaron M

    2014-01-01

    Extraglottic airway devices (EAD) have become an integral part of anesthetic care since their introduction into clinical practice 25 years ago and have been used safely hundreds of millions of times, worldwide. They are an important first option for difficult ventilation during both in-hospital and out-of-hospital difficult airway management and can be utilized as a conduit for tracheal intubation either blindly or assisted by another technology (fiberoptic endoscopy, lightwand). Thus, the EAD may be the most versatile single airway technique in the airway management toolbox. However, despite their utility, knowledge regarding specific devices and the supporting data for their use is of paramount importance to patient's safety. In this review, number of commercially available EADs are discussed and the reported benefits and potential pitfalls are highlighted. PMID:24741502

  10. United airway disease: current perspectives

    PubMed Central

    Giavina-Bianchi, Pedro; Aun, Marcelo Vivolo; Takejima, Priscila; Kalil, Jorge; Agondi, Rosana Câmara

    2016-01-01

    Upper and lower airways are considered a unified morphological and functional unit, and the connection existing between them has been observed for many years, both in health and in disease. There is strong epidemiologic, pathophysiologic, and clinical evidence supporting an integrated view of rhinitis and asthma: united airway disease in the present review. The term “united airway disease” is opportune, because rhinitis and asthma are chronic inflammatory diseases of the upper and lower airways, which can be induced by allergic or nonallergic reproducible mechanisms, and present several phenotypes. Management of rhinitis and asthma must be jointly carried out, leading to better control of both diseases, and the lessons of the Allergic Rhinitis and Its Impact on Asthma initiative cannot be forgotten. PMID:27257389

  11. Tube Law of the Pharyngeal Airway in Sleeping Patients with Obstructive Sleep Apnea

    PubMed Central

    Genta, Pedro R.; Edwards, Bradley A.; Sands, Scott A.; Owens, Robert L.; Butler, James P.; Loring, Stephen H.; White, David P.; Wellman, Andrew

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is characterized by repetitive pharyngeal collapse during sleep. However, the dynamics of pharyngeal narrowing and re-expansion during flow-limited breathing are not well described. The static pharyngeal tube law (end-expiratory area versus luminal pressure) has demonstrated increasing pharyngeal compliance as luminal pressure decreases, indicating that the airway would be sucked closed with sufficient inspiratory effort. On the contrary, the airway is rarely sucked closed during inspiratory flow limitation, suggesting that the airway is getting stiffer. Therefore, we hypothesized that during inspiratory flow limitation, as opposed to static conditions, the pharynx becomes stiffer as luminal pressure decreases. Methods: Upper airway endoscopy and simultaneous measurements of airflow and epiglottic pressure were performed during natural nonrapid eye movement sleep. Continuous positive (or negative) airway pressure was used to induce flow limitation. Flow-limited breaths were selected for airway cross-sectional area measurements. Relative airway area was quantified as a percentage of end-expiratory area. Inspiratory airway radial compliance was calculated at each quintile of epiglottic pressure versus airway area plot (tube law). Results: Eighteen subjects (14 males) with OSA (apnea-hypopnea index = 57 ± 27 events/h), aged 49 ± 8 y, with a body mass index of 35 ± 6 kg/m2 were studied. A total of 163 flow limited breaths were analyzed (9 ± 3 breaths per subject). Compliances at the fourth (2.0 ± 4.7 % area/cmH2O) and fifth (0.0 ± 1.7 % area/cmH2O) quintiles were significantly lower than the first (12.2 ± 5.5 % area/cmH2O) pressure quintile (P < 0.05). Conclusions: The pharyngeal tube law is concave (airway gets stiffer as luminal pressure decreases) during respiratory cycles under inspiratory flow limitation. Citation: Genta PR, Edwards BA, Sands SA, Owens RL, Butler JP, Loring SH, White DP, Wellman A. Tube law of

  12. Airway Surface Mycosis in Chronic Th2-Associated Airway Disease

    PubMed Central

    Porter, Paul; Lim, Dae Jun; Maskatia, Zahida Khan; Mak, Garbo; Tsai, Chu-Lin; Citardi, Martin J; Fakhri, Samer; Shaw, Joanne L.; Fothergil, Annette; Kheradmand, Farrah; Corry, David B; Luong, Amber

    2014-01-01

    Background Environmental fungi have been linked to T helper type 2 (Th2) cell-related airway inflammation and the Th2-associated chronic airway diseases asthma, chronic rhinosinusitis with nasal polyps (CRSwNP) and allergic fungal rhinosinusitis (AFRS), but whether these organisms participate directly or indirectly in disease pathology remains unknown. Objective To determine the frequency of fungus isolation and fungus-specific immunity in Th2-associated and non-associated airway disease patients. Methods Sinus lavage fluid and blood were collected from sinus surgery patients (n=118) including CRS patients with and without nasal polyps and AFRS and non-CRS/non-asthmatic control patients. Asthma status was deteremined from medical history. Sinus lavage fluids were cultured and directly examined for evidence of viable fungi. Peripheral blood mononuclear cells were restimulated with fungal antigens in an enzyme linked immunocell spot (ELISpot) assay to determine total memory fungus-specific IL-4-secreting cells. These data were compared to fungus-specific IgE levels measured from plasma by ELISA. Results Filamentous fungi were significantly more commonly cultured from Th2-associated airway disease subjects (asthma, CRSwNP, or AFRS: n=68) compared to non-Th2-associated control patients (n=31); 74% vs 16% respectively, p<0.001. Both fungus-specific IL-4 ELISpot (n=48) and specific IgE (n=70) data correlated with Th2-associated diseases (sensitivity 73% and specificity 100% vs. 50% and 77%, respectively). Conclusions The frequent isolation of fungi growing directly within the airways accompanied by specific immunity to these organisms only in patients with Th2-associated chronic airway diseases suggests that fungi participate directly in the pathogenesis of these conditions. Efforts to eradicate airway fungi from the airways should be considered in selected patients. Clinical Implications Airway fungi may contribute to the expression of sinusitis with nasal polyps and

  13. Obstructive Sleep Apnea in Adults: The Role of Upper Airway and Facial Skeletal Surgery.

    PubMed

    Garg, Ravi K; Afifi, Ahmed M; Sanchez, Ruston; King, Timothy W

    2016-10-01

    Obstructive sleep apnea represents a large burden of disease to the general population and may compromise patient quality of life; workplace and automotive safety; and metabolic, cardiovascular, and neurocognitive health. The disease is characterized by repetitive cycles of upper airway collapse resulting from a lack of pharyngeal airway structural support and loss of muscle tone among upper airway dilators. Polysomnography serves as the gold standard for diagnosis of obstructive sleep apnea and the apnea-hypopnea index is the most commonly used metric for quantifying disease severity. Conservative treatments include lifestyle modification, continuous positive airway pressure treatment, and dental appliance therapy. Surgical treatment options include pharyngeal and facial skeletal surgery. Maxillomandibular advancement has been shown to be the most effective surgical approach for multilevel expansion of the upper airway and may significantly reduce an obstructive sleep apnea patient's apnea-hypopnea index. Patient age, obesity, and the degree of maxillary advancement may be key factors contributing to treatment success. PMID:27673521

  14. A new removable airway stent

    PubMed Central

    Amundsen, Tore; Sørhaug, Sveinung; Leira, Håkon Olav; Tyvold, Stig Sverre; Langø, Thomas; Hammer, Tommy; Manstad-Hulaas, Frode; Mattsson, Erney

    2016-01-01

    Background Malignant airway obstruction is a feared complication and will most probably occur more frequently in the future because of increasing cancer incidence and increased life expectancy in cancer patients. Minimal invasive treatment using airway stents represents a meaningful and life-saving palliation. We present a new removable airway stent for improved individualised treatment. Methods To our knowledge, the new airway stent is the world's first knitted and uncovered self-expanding metal stent, which can unravel and be completely removed. In an in vivo model using two anaesthetised and spontaneously breathing pigs, we deployed and subsequently removed the stents by unravelling the device. The procedures were executed by flexible bronchoscopy in an acute and a chronic setting – a ‘proof-of-principle’ study. Results The new stent was easily and accurately deployed in the central airways, and it remained fixed in its original position. It was easy to unravel and completely remove from the airways without clinically significant complications. During the presence of the stent in the chronic study, granulation tissue was induced. This tissue disappeared spontaneously with the removal. Conclusions The new removable stent functioned according to its purpose and unravelled easily, and it was completely removed without significant technical or medical complications. Induced granulation tissue disappeared spontaneously. Further studies on animals and humans are needed to define its optimal indications and future use. PMID:27608269

  15. Airway turbulence and changes in upper airway hydraulic diameter can be estimated from the intensity of high frequency inspiratory sounds in sleeping adults

    PubMed Central

    Rembold, Christopher M; Suratt, Paul M

    2014-01-01

    Obstructive sleep disordered breathing can cause death and significant morbidity in adults and children. We previously found that children with smaller upper airways (measured by magnetic resonance imaging while awake) generated loud high frequency inspiratory sounds (HFIS, defined as inspiratory sounds > 2 kHz) while they slept. The purpose of this study was (1) to determine what characteristics of airflow predicted HFIS intensity, and (b) to determine if we could calculate changes in hydraulic diameter (D) in both an in vitro model and in the upper airways of sleeping humans. In an in vitro model, high frequency sound intensity was an estimate of airflow turbulence as reflected by the Reynold's number (Re). D of the in vitro model was calculated using Re, the pressure gradient, Swamee–Jain formula and Darcy formula. D was proportional to but smaller than the actual diameters (r2 = 0.94). In humans, we measured HFIS intensity and the pressure gradient across the upper airway (estimated with oesophageal pressure, Pes) during polysomnography in four adult volunteers and applied the same formulae to calculate D. At apnoea termination when the airway opens, we observed (1) an increase in HFIS intensity suggesting an increase in turbulence (higher Re), and (2) a larger calculated D. This method allows dynamic estimation of changes in relative upper airway hydraulic diameter (D) in sleeping humans with narrowed upper airways. PMID:24973405

  16. Human airway ciliary dynamics

    PubMed Central

    Thompson, Kristin; Knowles, Michael R.; Davis, C. William

    2013-01-01

    Airway cilia depend on precise changes in shape to transport the mucus gel overlying mucosal surfaces. The ciliary motion can be recorded in several planes using video microscopy. However, cilia are densely packed, and automated computerized systems are not available to convert these ciliary shape changes into forms that are useful for testing theoretical models of ciliary function. We developed a system for converting planar ciliary motions recorded by video microscopy into an empirical quantitative model, which is easy to use in validating mathematical models, or in examining ciliary function, e.g., in primary ciliary dyskinesia (PCD). The system we developed allows the manipulation of a model cilium superimposed over a video of beating cilia. Data were analyzed to determine shear angles and velocity vectors of points along the cilium. Extracted waveforms were used to construct a composite waveform, which could be used as a standard. Variability was measured as the mean difference in position of points on individual waveforms and the standard. The shapes analyzed were the end-recovery, end-effective, and fastest moving effective and recovery with mean (± SE) differences of 0.31(0.04), 0.25(0.06), 0.50(0.12), 0.50(0.10), μm, respectively. In contrast, the same measures for three different PCD waveforms had values far outside this range. PMID:23144323

  17. Airway Hydration and COPD

    PubMed Central

    Ghosh, Arunava; Boucher, R.C.; Tarran, Robert

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is one of the prevalent causes of worldwide mortality and encompasses two major clinical phenotypes, i.e., chronic bronchitis (CB) and emphysema. The most common cause of COPD is chronic tobacco inhalation. Research focused on the chronic bronchitic phenotype of COPD has identified several pathological processes that drive disease initiation and progression. For example, the lung’s mucociliary clearance (MCC) system performs the critical task of clearing inhaled pathogens and toxic materials from the lung. MCC efficiency is dependent on: (i) the ability of apical plasma membrane ion channels such as the cystic fibrosis transmembrane conductance regulator (CFTR) and the epithelial Na+ channel (ENaC) to maintain airway hydration; (ii) ciliary beating; and, (iii) appropriate rates of mucin secretion. Each of these components is impaired in CB and likely contributes to the mucus stasis/accumulation seen in CB patients. This review highlights the cellular components responsible for maintaining MCC and how this process is disrupted following tobacco exposure and with CB. We shall also discuss existing therapeutic strategies for the treatment of chronic bronchitis and how components of the MCC can be used as biomarkers for the evaluation of tobacco or tobacco-like-product exposure. PMID:26068443

  18. Dynamic Visco-elastic Buckling Analysis for Airway Model

    NASA Astrophysics Data System (ADS)

    Bando, Kiyoshi; Ohba, Kenkichi; Yamanoi, Yuta

    In order to clarify the mechanism by which the lung airway narrows during an asthma attack, dynamic buckling analysis of the wall was conducted. The wall was modeled using a visco-elastic thin-walled circular cylinder of the Voigt model for the planestress state. A governing equation for dynamic buckling was derived, and in the equation, the contraction of smooth muscle was replaced by uniform inward transmural pressure. The non-dimensional parameters for the buckling wave number n were nondimensional retardation time τ, non-dimensional increasing velocity of inward transmural pressure β, thickness radius ratio α2, radius length ratio η, density ratio ζ, and Poisson's ratio ν. The validity of the theoretical model was confirmed by comparing the calculated wave number with that obtained from the experiment, in which a silicone rubber tube blended with silicone potting gel was used as the in vitro airway model. In addition, the wave number n increased with β. It was necessary to consider the damping effect of the tube model or the airway wall, and n increased by 1.5 to 2 due to the additional mass effect of surrounding tissues of the basement membrane in the airway wall.

  19. On locating the obstruction in the human upper airway

    NASA Astrophysics Data System (ADS)

    Wang, Yong; Elghobashi, S.

    2013-11-01

    The fluid dynamical properties of the air flow in the human upper airway (UA) are not fully understood at present due to the three-dimensional, patient-specific complex geometry of the airway, flow transition from laminar to turbulent and flow-structure interaction during the breathing cycle. One of the major challenges to surgeons is determining the location of the UA obstruction before performing corrective surgeries. It is quite difficult at present to experimentally measure the instantaneous velocity and pressure at specific points in the human airway. On the other hand, direct numerical simulation (DNS) can predict all the flow properties and resolve all its relevant length- and time-scales. We developed a DNS solver with lattice Boltzmann method (LBM), and used it to investigate the flow in two patient-specific UAs reconstructed from CT scan data. Inspiration and expiration flows through these two airways are studied and compared. Pressure gradient-time signals at different locations in the UAs are used to determine the location of the obstruction. This work was supported by the National Heart, Lung, and Blood Institute (NHLBI) of the National Institutes of Health (NIH).

  20. Oxygenation, ventilation, and airway management in out-of-hospital cardiac arrest: a review.

    PubMed

    Henlin, Tomas; Michalek, Pavel; Tyll, Tomas; Hinds, John D; Dobias, Milos

    2014-01-01

    Recently published evidence has challenged some protocols related to oxygenation, ventilation, and airway management for out-of-hospital cardiac arrest. Interrupting chest compressions to attempt airway intervention in the early stages of OHCA in adults may worsen patient outcomes. The change of BLS algorithms from ABC to CAB was recommended by the AHA in 2010. Passive insufflation of oxygen into a patent airway may provide oxygenation in the early stages of cardiac arrest. Various alternatives to tracheal intubation or bag-mask ventilation have been trialled for prehospital airway management. Simple methods of airway management are associated with similar outcomes as tracheal intubation in patients with OHCA. The insertion of a laryngeal mask airway is probably associated with worse neurologically intact survival rates in comparison with other methods of airway management. Hyperoxemia following OHCA may have a deleterious effect on the neurological recovery of patients. Extracorporeal oxygenation techniques have been utilized by specialized centers, though their use in OHCA remains controversial. Chest hyperinflation and positive airway pressure may have a negative impact on hemodynamics during resuscitation and should be avoided. Dyscarbia in the postresuscitation period is relatively common, mainly in association with therapeutic hypothermia, and may worsen neurological outcome.

  1. Efficacy of Surgical Airway Plasty for Benign Airway Stenosis

    PubMed Central

    Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Inoue, Hidetoshi; Yamamoto, Ryoji

    2015-01-01

    Background: Long-term patency is required during treatment for benign airway stenosis. This study investigated the effectiveness of surgical airway plasty for benign airway stenosis. Methods: Clinical courses of 20 patients, who were treated with surgical plasty for their benign airway stenosis, were retrospectively investigated. Results: Causes of stenosis were tracheobronchial tuberculosis in 12 patients, post-intubation stenosis in five patients, malacia in two patients, and others in one patient. 28 interventional pulmonology procedures and 20 surgical plasty were performed. Five patients with post-intubation stenosis and four patients with tuberculous stenosis were treated with tracheoplasty. Eight patients with tuberculous stenosis were treated with bronchoplasty, and two patients with malacia were treated with stabilization of the membranous portion. Anastomotic stenosis was observed in four patients, and one to four additional treatments were required. Performance status, Hugh–Jones classification, and ventilatory functions were improved after surgical plasty. Outcomes were fair in patients with tuberculous stenosis and malacia. However, efficacy of surgical plasty for post-intubation stenosis was not observed. Conclusion: Surgical airway plasty may be an acceptable treatment for tuberculous stenosis. Patients with malacia recover well after surgical plasty. There may be untreated patients with malacia who have the potential to benefit from surgical plasty. PMID:26567879

  2. Effects of hypercapnia and inspiratory flow-resistive loading on respiratory activity in chronic airways obstruction.

    PubMed Central

    Altose, M D; McCauley, W C; Kelsen, S G; Cherniack, N S

    1977-01-01

    The respiratory responses to hypercapnia alone and to hypercapnia and flow-resistive loading during inspiration were studied in normal individuals and in eucapnic and hypercapnic patients with chronic airways obstruction. Responses were assessed in terms of minute ventilation and occlusion pressure (mouth pressure during airway occlusion 100 ms after the onset of inspiration). Ventilatory responses to CO2 (deltaV/deltaPCO2) were distinctly subnormal in both groups of patients with airways obstruction. The two groups of patients, however, showed different occlusion pressure responses to CO2 (deltaP100/deltaPCO2): deltaP100/deltaPCO2 was normal in the eucapnic patients but subnormal in the hypercapnic patients. Flow-resistive loading during inspiration reduced deltaV/deltaPCO2 both in normal subjects and in patients with airways obstruction. The occlusion pressure response to CO2 increased in normal subjects during flow-resistive loading but remained unchanged in both groups of patients with chronic airways obstruction. These results indicate that while chemosensitivity as determined by deltaP100/deltaPCO2 is impaired only in hypercapnic patients with chronic airways obstruction, an acute increase in flow resistance elicits a subnormal increase in respiratory efferent activity in both eucapnic and hypercapnic patients. PMID:838862

  3. Comparison of streamlined liner of the pharynx airway (SLIPA ™) and laryngeal mask airway: a systematic review and meta-analysis.

    PubMed

    Choi, G J; Kang, H; Baek, C W; Jung, Y H; Woo, Y C; Kim, S H; Kim, J G

    2015-05-01

    We performed a systematic review to compare the efficacy and safety of the streamlined liner of the pharynx airway and laryngeal mask airway used in adults during general anaesthesia. We included 14 studies with studies with 1273 patients in total. There was no evidence of a difference between the two devices in insertion success rate on the first attempt (13 studies, 1143 patients), insertion time (seven studies, 576 patients), ease of insertion (five studies, 466 patients), oropharyngeal leak pressure (eight studies, 771 patients) and the quality of the fibreoptic view of the larynx through the device (three studies, 281 patients). The relative risk (95% CI) of bloodstaining of the device (nine studies, 859 patients) was 2.09 (1.46-3.00) for the streamlined liner of the pharynx airway compared with the laryngeal mask airway. Other adverse events were comparable. Subgroup analysis suggested that the insertion by novice users might be faster and more successful with the streamlined liner of the pharynx airway than the laryngeal mask airway; however, this was from only two studies and 186 patients. The method of size selection of the streamlined liner of the pharynx airway device might also affect the speed of insertion: choosing according to the width of the patient's thyroid cartilage, rather than height, may produce better results.

  4. Engineering sleep disorders: from classical CPAP devices toward new intelligent adaptive ventilatory therapy.

    PubMed

    Jane, Raimon

    2014-01-01

    Among the most common sleep disorders are those related to disruptions in airflow (apnea) or reductions in the breath amplitude (hypopnea) with or without obstruction of the upper airway (UA). One of the most important sleep disorders is obstructive sleep apnea (OSA). This sleep-?disordered breathing, quantified by the apnea??hypopnea index (AHI), can produce a significant reduction of oxygen saturation and an abnormal elevation of carbon dioxide levels in the blood. Apnea and hypopnea episodes are associated with arousals and sleep fragmentation during the night and compensatory response of the autonomic nervous system. PMID:25437472

  5. Blockage of upper airway

    MedlinePlus

    ... closed, including allergic reactions to a bee sting , peanuts, antibiotics (such as penicillin), and blood pressure medicines ( ... from breathing in smoke Foreign bodies, such as peanuts and other breathed-in foods, pieces of a ...

  6. Cellular strain amplifies lps-induced stress signaling in immature enterocytes: potential implications for preterm infant nasal CPAP

    PubMed Central

    Alcamo, Alicia M.; Schanbacher, Brandon L.; Huang, Hong; Nankervis, Craig A.; Bauer, John A.; Giannone, Peter J.

    2013-01-01

    Background Recent clinical observations of increased necrotizing enterocolitis (NEC) incidence in some Nasal Continuous Positive Airway Pressure (NCPAP) patients raise concerns whether the related abdominal distension is benign or contributes to NEC. We tested the hypothesis that mechanical strain causes an exaggerated enterocyte inflammatory response and decreased enterocyte growth and proliferation, in the absence and presence of lipopolysaccharide (LPS). Methods First we used a confluent enterocyte (IEC-6) monolayer to investigate effects of strain on inflammatory cytokine production and Toll-like Receptor 4 (TLR4) gene expression. Then we used a low seeding density to measure cell growth and proliferation. 10% mechanical strain was applied. Results Significant increases in IL-8 and in IL-6 were observed after 8 and 24 h of cellular strain respectively, and maintained throughout the study. TLR-4 expression was increased at 48 hours. Mechanical strain led to slower proliferation and division whereas LPS alone had minimal effects. The responses of LPS and strain were supra-additive, suggesting synergistic cellular effects. Conclusion We speculate intestinal distension associated with the use of NCPAP, especially in the presence of abnormal gut colonization, may result in increased inflammatory cytokine production and be a contributing factor to neonatal intestinal morbidities. PMID:22810014

  7. Allergen-induced airway responses.

    PubMed

    Gauvreau, Gail M; El-Gammal, Amani I; O'Byrne, Paul M

    2015-09-01

    Environmental allergens are an important cause of asthma and can contribute to loss of asthma control and exacerbations. Allergen inhalation challenge has been a useful clinical model to examine the mechanisms of allergen-induced airway responses and inflammation. Allergen bronchoconstrictor responses are the early response, which reaches a maximum within 30 min and resolves by 1-3 h, and late responses, when bronchoconstriction recurs after 3-4 h and reaches a maximum over 6-12 h. Late responses are followed by an increase in airway hyperresponsiveness. These responses occur when IgE on mast cells is cross-linked by an allergen, causing degranulation and the release of histamine, neutral proteases and chemotactic factors, and the production of newly formed mediators, such as cysteinyl leukotrienes and prostaglandin D2. Allergen-induced airway inflammation consists of an increase in airway eosinophils, basophils and, less consistently, neutrophils. These responses are mediated by the trafficking and activation of myeloid dendritic cells into the airways, probably as a result of the release of epithelial cell-derived thymic stromal lymphopoietin, and the release of pro-inflammatory cytokines from type 2 helper T-cells. Allergen inhalation challenge has also been a widely used model to study potential new therapies for asthma and has an excellent negative predictive value for this purpose. PMID:26206871

  8. The Airway Microbiome at Birth

    PubMed Central

    Lal, Charitharth Vivek; Travers, Colm; Aghai, Zubair H.; Eipers, Peter; Jilling, Tamas; Halloran, Brian; Carlo, Waldemar A.; Keeley, Jordan; Rezonzew, Gabriel; Kumar, Ranjit; Morrow, Casey; Bhandari, Vineet; Ambalavanan, Namasivayam

    2016-01-01

    Alterations of pulmonary microbiome have been recognized in multiple respiratory disorders. It is critically important to ascertain if an airway microbiome exists at birth and if so, whether it is associated with subsequent lung disease. We found an established diverse and similar airway microbiome at birth in both preterm and term infants, which was more diverse and different from that of older preterm infants with established chronic lung disease (bronchopulmonary dysplasia). Consistent temporal dysbiotic changes in the airway microbiome were seen from birth to the development of bronchopulmonary dysplasia in extremely preterm infants. Genus Lactobacillus was decreased at birth in infants with chorioamnionitis and in preterm infants who subsequently went on to develop lung disease. Our results, taken together with previous literature indicating a placental and amniotic fluid microbiome, suggest fetal acquisition of an airway microbiome. We speculate that the early airway microbiome may prime the developing pulmonary immune system, and dysbiosis in its development may set the stage for subsequent lung disease. PMID:27488092

  9. Numerical simulation of soft palate movement and airflow in human upper airway by fluid-structure interaction method

    NASA Astrophysics Data System (ADS)

    Sun, Xiuzhen; Yu, Chi; Wang, Yuefang; Liu, Yingxi

    2007-08-01

    In this paper, the authors present airflow field characteristics of human upper airway and soft palate movement attitude during breathing. On the basis of the data taken from the spiral computerized tomography images of a healthy person and a patient with Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS), three-dimensional models of upper airway cavity and soft palate are reconstructed by the method of surface rendering. Numerical simulation is performed for airflow in the upper airway and displacement of soft palate by fluid-structure interaction analysis. The reconstructed three-dimensional models precisely preserve the original configuration of upper airways and soft palate. The results of the pressure and velocity distributions in the airflow field are quantitatively determined, and the displacement of soft palate is presented. Pressure gradients of airway are lower for the healthy person and the airflow distribution is quite uniform in the case of free breathing. However, the OSAHS patient remarkably escalates both the pressure and velocity in the upper airway, and causes higher displacement of the soft palate. The present study is useful in revealing pathogenesis and quantitative mutual relationship between configuration and function of the upper airway as well as in diagnosing diseases related to anatomical structure and function of the upper airway.

  10. Postnatal Exposure History and Airways

    PubMed Central

    Murphy, Shannon R.; Schelegle, Edward S.; Edwards, Patricia C.; Miller, Lisa A.; Hyde, Dallas M.

    2012-01-01

    Postnatally, the lung continues to grow and differentiate while interacting with the environment. Exposure to ozone (O3) and allergens during postnatal lung development alters structural elements of conducting airways, including innervation and neurokinin abundance. These changes have been linked with development of asthma in a rhesus monkey model. We hypothesized that O3 exposure resets the ability of the airways to respond to oxidant stress and that this is mediated by changes in the neurokinin-1 receptor (NK-1R). Infant rhesus monkeys received episodic exposure to O3 biweekly with or without house dust mite antigen (HDMA) from 6 to 12 months of age. Age-matched monkeys were exposed to filtered air (FA). Microdissected airway explants from midlevel airways (intrapulmonary generations 5–8) for four to six animals in each of four groups (FA, O3, HDMA, and HDMA+O3) were tested for NK-1R gene responses to acute oxidant stress using exposure to hydrogen peroxide (1.2 mM), a lipid ozonide (10 μM), or sham treatment for 4 hours in vitro. Airway responses were measured using real-time quantitative RT-PCR of NK-1R and IL-8 gene expression. Basal NK-1R gene expression levels were not different between the exposure groups. Treatment with ozonide or hydrogen peroxide did not change NK-1R gene expression in animals exposed to FA, HDMA, or HDMA+O3. However, treatment in vitro with lipid ozonide significantly increased NK-1R gene expression in explants from O3–exposed animals. We conclude that a history of prior O3 exposure resets the steady state of the airways to increase the NK-1R response to subsequent acute oxidant stresses. PMID:22962062

  11. Airway surface liquid volume expansion induces rapid changes in amiloride-sensitive Na+ transport across upper airway epithelium-Implications concerning the resolution of pulmonary edema.

    PubMed

    Azizi, Fouad; Arredouani, Abdelilah; Mohammad, Ramzi M

    2015-09-01

    During airway inflammation, airway surface liquid volume (ASLV) expansion may result from the movement of plasma proteins and excess liquid into the airway lumen due to extravasation and elevation of subepithelial hydrostatic pressure. We previously demonstrated that elevation of submucosal hydrostatic pressure increases airway epithelium permeability resulting in ASLV expansion by 500 μL cm(-2) h(-1). Liquid reabsorption by healthy airway epithelium is regulated by active Na(+) transport at a rate of 5 μL cm(-2) h(-1). Thus, during inflammation the airway epithelium may be submerged by a large volume of luminal liquid. Here, we have investigated the mechanism by which ASLV expansion alters active epithelial Na(+) transport, and we have characterized the time course of the change. We used primary cultures of tracheal airway epithelium maintained under air interface (basal ASLV, depth is 7 ± 0.5 μm). To mimic airway flooding, ASLV was expanded to a depth of 5 mm. On switching from basal to expanded ASLV conditions, short-circuit current (Isc, a measure of total transepithelial active ion transport) declined by 90% with a half-time (t1/2) of 1 h. 24 h after the switch, there was no significant change in ATP concentration nor in the number of functional sodium pumps as revealed by [(3)H]-ouabain binding. However, amiloride-sensitive uptake of (22)Na(+) was reduced by 70% upon ASLV expansion. This process is reversible since after returning cells back to air interface, Isc recovered with a t1/2 of 5-10 h. These results may have important clinical implications concerning the development of Na(+) channels activators and resolution of pulmonary edema.

  12. Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis

    PubMed Central

    Ahn, Eun Jin; Choi, Geun Joo; Kang, Hyun; Baek, Chong Wha; Jung, Yong Hun; Woo, Young Cheol; Bang, Si Ra

    2016-01-01

    Air-Q® (air-Q) is a supraglottic airway device which can be used as a guidance of intubation in pediatric as well as in adult patients. We evaluated the efficacy and safety of air-Q compared to other airway devices during general anesthesia in pediatric patients by conducting a systematic review and meta-analysis. A total of 10 studies including 789 patients were included in the final analysis. Compared with other supraglottic airway devices, air-Q showed no evidence for a difference in leakage pressure and insertion time. The ease of insertion was significantly lower than other supraglottic airway devices. The success rate of intubation was significantly lower than other airway devices. However, fiberoptic view was better through the air-Q than other supraglottic airway devices. Therefore, air-Q could be a safe substitute for other airway devices and may provide better fiberoptic bronchoscopic view. PMID:27419134

  13. An Anesthesiologist's Perspective on the History of Basic Airway Management: The "Preanesthetic" Era-1700 to 1846.

    PubMed

    Matioc, Adrian A

    2016-02-01

    Basic airway management modern history starts in the early 18th century in the context of resuscitation of the apparently dead. History saw the rise and fall of the mouth-to-mouth and then of the instrumental positive-pressure ventilation generated by bellows. Pulmonary ventilation had a secondary role to external and internal organ stimulation in resuscitation of the apparently dead. Airway access for the extraglottic technique was to the victim's nose. The bellows-to-nose technique was the "basic airway management technique" applicable by both medical and nonmedical personnel. Although the techniques had been described at the time, very few physicians practiced glottic (intubation) and subglottic (tracheotomy) techniques. Before the anesthetic era, positive-pressure ventilation was discredited and replaced by manual negative-pressure techniques. In the middle of the 19th century, physicians who would soon administer anesthetic gases were unfamiliar with the positive-pressure ventilation concept.

  14. Airway Assessment for Office Sedation/Anesthesia.

    PubMed

    Rosenberg, Morton B; Phero, James C

    2015-01-01

    Whenever a patient is about to receive sedation or general anesthesia, no matter what the technique, the preoperative assessment of the airway is one of the most important steps in ensuring patient safety and positive outcomes. This article, Part III in the series on airway management, is directed at the ambulatory office practice and focuses on predicting the success of advanced airway rescue techniques.

  15. A prospective cohort study of the long-term effects of CPAP on carotid artery intima-media thickness in Obstructive sleep apnea syndrome

    PubMed Central

    2012-01-01

    Objective To examine the long-term effect of CPAP on carotid artery intima-media thickness (IMT) in patients with Obstructive sleep apnea syndrome(OSAS). Methods A prospective observational study over 12 months at a teaching hospital on 50 patients newly diagnosed with OSAS who received CPAP or conservative treatment (CT). Carotid IMT was assessed with B-mode Doppler ultrasound from both carotid arteries using images of the far wall of the distal 10 mm of the common carotid arteries at baseline, 6 months and 12 months. Measurements and results [mean (SE)] Altogether 28 and 22 patients received CPAP and CT respectively without significant differences in age 48.8(1.8) vs 50.5(2.0)yrs, BMI 28.2(0.7) vs 28.0(1.2)kg/m2, ESS 13.1(0.7) vs 12.7(0.6), AHI 38(3) vs 39(3)/hr, arousal index 29(2) vs 29(2)/hr, minimum SaO2 75(2) vs 77(2)% and existing co-morbidities. CPAP usage was 4.6(0.3) and 4.7(0.4)hrs/night over 6 months and 1 year respectively. Carotid artery IMT at baseline, 6 months, and 12 months were 758(30), 721(20), and 705(20)micron for the CPAP group versus 760(30), 770(30), and 778(30)micron respectively for the CT group, p = 0.002. Among those free of cardiovascular disease(n = 24), the carotid artery IMT at baseline, 6 months and 12 months were 722(40), 691(40), and 659(30)micron for the CPAP group (n = 12) with usage 4.5(0.7) and 4.7(0.7) hrs/night over 6 months and 12 months whereas the IMT data for the CT group(n = 12) were 660(20), 685(10), and 690(20)micron respectively, p = 0.006. Conclusions Reduction of carotid artery IMT occurred mostly in the first 6 months and was sustained at 12 months in patients with reasonable CPAP compliance. PMID:22424053

  16. Computational Fluid Dynamic Analysis of the Posterior Airway Space After Maxillomandibular Advancement For Obstructive Sleep Apnea Syndrome

    PubMed Central

    Sittitavornwong, Somsak; Waite, Peter D.; Shih, Alan M.; Cheng, Gary C.; Koomullil, Roy; Ito, Yasushi; Cure, Joel K; Harding, Susan M.; Litaker, Mark

    2013-01-01

    Purpose Evaluate the soft tissue change of the upper airway after maxillomandibular advancement (MMA) by computational fluid dynamics (CFD). Materials and Methods Eight OSAS patients who required MMA were recruited into this study. All participants had pre- and post-operative computed tomography (CT) and underwent MMA by a single oral and maxillofacial surgeon. Upper airway CT data sets for these 8 participants were created with high-fidelity 3-D numerical models for computational fluid dynamics (CFD). The 3-D models were simulated and analyzed to study how changes in airway anatomy affects pressure effort required for normal breathing. Airway dimensions, skeletal changes, Apnea-Hypopnea Index (AHI), and pressure efforts of pre- and post-operative 3-D models were compared and correlations interpreted. Results After MMA, laminar and turbulent air flow was significantly decreased at every level of the airway. The cross-sectional areas at the soft palate and tongue base were significantly increased. Conclusions This study shows that MMA increases airway dimensions by the increasing the occipital base (Base) - pogonion (Pg) distance. An increase of the Base-Pg distance showed a significant correlation with an AHI improvement and a decreased pressure effort of the upper airway. Decreasing the pressure effort will decrease the breathing workload. This improves the condition of OSAS. PMID:23642544

  17. Nasal airway impairment: the oral response in cleft palate patients.

    PubMed

    Warren, D W; Hairfield, W M; Dalston, E T

    1991-04-01

    The purpose of this study was to assess the oral response to severe nasal airway impairment in patients with cleft palate. Inductive plethysmography was used to measure the percent of nasal breathing, and the pressure-flow technique was used to estimate nasal area in 15 persons with severe nasal airway impairment. Mean nasal area was 0.17 cm2, and the average percent of nasal breathing was 20%. Analysis revealed a strong correlation (0.87) between nasal size and percent of nasal breathing in this selected group. Modeling studies based on the mean values from the subjects' data indicated that the model "mouth" would have to open 0.5 cm2 to shunt 80% of the airflow orally, an amount equivalent to the mean value of the subjects' respiratory mode. More important, the extrapolated data revealed that upper-airway resistance decreased in the model from 8.7 cm H2O/L/sec to a level of 3.2 cm H2O/L/sec, which is an average value for healthy adults. These data support the concept that the mouth acts as a variable resistor to maintain an optimal respiratory tract resistance when the nasal airway is impaired. PMID:2008894

  18. [Airway equipment and its maintenance for a non difficult adult airway management (endotracheal intubation and its alternative: face mask, laryngeal mask airway, laryngeal tube)].

    PubMed

    Francon, D; Estèbe, J P; Ecoffey, C

    2003-08-01

    The airway equipment for a non difficult adult airway management are described: endotracheal tubes with a specific discussion on how to inflate the balloon, laryngoscopes and blades, stylets and intubation guides, oral airways, face masks, laryngeal mask airways and laryngeal tubes. Cleaning and disinfections with the maintenance are also discussed for each type of airway management.

  19. A pilot study to examine the effect of the Tulip oropharyngeal airway on ventilation immediately after mask ventilation following the induction of anaesthesia.

    PubMed

    Robinson, P N; Shaikh, A; Sabir, N M; Vaughan, D J A; Kynoch, M; Hasan, M

    2014-07-01

    The Tulip airway is an adult, disposable, single-sized oropharyngeal airway, that is connectable to an anaesthetic circuit. After a standardised induction of anaesthesia in 75 patients, the ease of insertion, intracuff pressure and intracuff volume were measured, as were the end-tidal carbon dioxide levels, airway pressures and tidal volumes over three breaths. Successful first-time insertion was achieved in 72 patients (96%, CI 88.8-99.2%) and after two attempts in 74 patients (99%, CI 92.8-100%). There was outright failure only in one patient. In 60 patients (80%, CI 72.2-90.4%), the Tulip airway provided a patent airway without additional manoeuvres, but in 14 patients, jaw thrust or head extension was necessary for airway patency. The main need for these adjuncts appeared to be an initial under-inflation of the cuff. These promising results are consistent with recent manikin studies using this device.

  20. A pilot study to examine the effect of the Tulip oropharyngeal airway on ventilation immediately after mask ventilation following the induction of anaesthesia.

    PubMed

    Robinson, P N; Shaikh, A; Sabir, N M; Vaughan, D J A; Kynoch, M; Hasan, M

    2014-07-01

    The Tulip airway is an adult, disposable, single-sized oropharyngeal airway, that is connectable to an anaesthetic circuit. After a standardised induction of anaesthesia in 75 patients, the ease of insertion, intracuff pressure and intracuff volume were measured, as were the end-tidal carbon dioxide levels, airway pressures and tidal volumes over three breaths. Successful first-time insertion was achieved in 72 patients (96%, CI 88.8-99.2%) and after two attempts in 74 patients (99%, CI 92.8-100%). There was outright failure only in one patient. In 60 patients (80%, CI 72.2-90.4%), the Tulip airway provided a patent airway without additional manoeuvres, but in 14 patients, jaw thrust or head extension was necessary for airway patency. The main need for these adjuncts appeared to be an initial under-inflation of the cuff. These promising results are consistent with recent manikin studies using this device. PMID:24773326

  1. Inflammatory bowel disease and airway diseases

    PubMed Central

    Vutcovici, Maria; Brassard, Paul; Bitton, Alain

    2016-01-01

    Airway diseases are the most commonly described lung manifestations of inflammatory bowel disease (IBD). However, the similarities in disease pathogenesis and the sharing of important environmental risk factors and genetic susceptibility suggest that there is a complex interplay between IBD and airway diseases. Recent evidence of IBD occurrence among patients with airway diseases and the higher than estimated prevalence of subclinical airway injuries among IBD patients support the hypothesis of a two-way association. Future research efforts should be directed toward further exploration of this association, as airway diseases are highly prevalent conditions with a substantial public health impact. PMID:27678355

  2. Inflammatory bowel disease and airway diseases

    PubMed Central

    Vutcovici, Maria; Brassard, Paul; Bitton, Alain

    2016-01-01

    Airway diseases are the most commonly described lung manifestations of inflammatory bowel disease (IBD). However, the similarities in disease pathogenesis and the sharing of important environmental risk factors and genetic susceptibility suggest that there is a complex interplay between IBD and airway diseases. Recent evidence of IBD occurrence among patients with airway diseases and the higher than estimated prevalence of subclinical airway injuries among IBD patients support the hypothesis of a two-way association. Future research efforts should be directed toward further exploration of this association, as airway diseases are highly prevalent conditions with a substantial public health impact.

  3. Lung function and airway diseases.

    PubMed

    Weiss, Scott T

    2010-01-01

    Two studies report genome-wide association studies for lung function, using cross-sectional spirometric measurements in healthy individuals. They identify six genetic loci newly associated to natural variation in lung function, which may have implications for the related airway diseases of asthma and chronic obstructive pulmonary disease. PMID:20037613

  4. Upper airway function in the pathogenesis of obstructive sleep apnea: a review of the current literature

    PubMed Central

    Owens, Robert L.; Eckert, Danny J.; Yeh, Susie Yim; Malhotra, Atul

    2009-01-01

    Purpose of review Obstructive sleep apnea is an increasingly prevalent disease, with a considerable societal burden. The disease is defined by recurrent intermittent collapse of the upper airway. Understanding of and treatment for the disease is largely confined to relief of the mechanical obstruction of the upper airway by application of continuous positive airway pressure, and less commonly weight loss or surgery. However, recent work has focused on the function, rather than structure alone, of the upper airway. Recent findings The following contributors to upper airway structure and function have been studied: traditional fixed anatomical abnormalities, dynamic anatomical changes, upper airway dilator muscle dysfunction, lung volumes, and instability in control of breathing. In each patient with obstructive sleep apnea, the relative contribution of each of these components may be quite variable. The studies reviewed here describe methods to evaluate these factors, and some attempts at treatment. Summary Ongoing studies are attempting to classify patients on the basis of the underlying pathophysiology. This work suggests that obstructive sleep apnea is a heterogeneous disease with multiple root causes. Ultimately, such a classification may allow more individualized treatment, not only relying on mechanical relief of the upper airway obstruction. PMID:18812828

  5. Management of the difficult airway.

    PubMed

    Schwartz, D E; Wiener-Kronish, J P

    1991-09-01

    For clinicians involved in airway management, a plan of action for dealing with the difficult airway or a failed intubation should be developed well in advance of encountering a patient in whom intubation is not routine. When difficulty is anticipated, the equipment necessary for performing a difficult intubation should be immediately available. It also is prudent to have a surgeon skilled in performing a tracheotomy and a criothyroidotomy stand by. The intubation should be attempted in the awake state, preferably using the fiberoptic bronchoscope. The more challenging situation is when the difficult airway is confronted unexpectedly. After the first failed attempt at laryngoscopy, head position should be checked and the patient ventilated with oxygen by mask. A smaller styletted tube and possibly a different laryngoscope blade should be selected for a second attempt at intubation. The fiberoptic bronchoscope and other equipment for difficult intubation should be obtained. A second attempt should then be made. If this is unsuccessful, the patient should be reoxygenated, and assistance including a skilled anesthesiologist and surgeon should be summoned. On a third attempt, traction to the tongue can be applied by an assistant, a tube changer could be used to enter the larynx, or one of the other special techniques previously described can be used. If this third attempt fails, it may be helpful to have a physician more experienced in airway management attempt intubation after oxygen has been administered to the patient. If all attempts are unsuccessful, then invasive techniques to secure the airway will have to be performed. PMID:1934950

  6. Cenpj/CPAP regulates progenitor divisions and neuronal migration in the cerebral cortex downstream of Ascl1

    PubMed Central

    Garcez, Patricia P.; Diaz-Alonso, Javier; Crespo-Enriquez, Ivan; Castro, Diogo; Bell, Donald; Guillemot, François

    2015-01-01

    The proneural factor Ascl1 controls multiple steps of neurogenesis in the embryonic brain, including progenitor division and neuronal migration. Here we show that Cenpj, also known as CPAP, a microcephaly gene, is a transcriptional target of Ascl1 in the embryonic cerebral cortex. We have characterized the role of Cenpj during cortical development by in utero electroporation knockdown and found that silencing Cenpj in the ventricular zone disrupts centrosome biogenesis and randomizes the cleavage plane orientation of radial glia progenitors. Moreover, we show that downregulation of Cenpj in post-mitotic neurons increases stable microtubules and leads to slower neuronal migration, abnormal centrosome position and aberrant neuronal morphology. Moreover, rescue experiments shows that Cenpj mediates the role of Ascl1 in centrosome biogenesis in progenitor cells and in microtubule dynamics in migrating neurons. These data provide insights into genetic pathways controlling cortical development and primary microcephaly observed in humans with mutations in Cenpj. PMID:25753651

  7. [Supraglottic airways in infants and children].

    PubMed

    Goldmann, Kai

    2013-04-01

    The development of the LMA-Classic™ revolutionized anaesthesia practice as its wide-spread use led to the establishment of a unique form of airway management, the "supraglottic airway management", besides the existing classical airway management with the face mask or endotracheal tube. Today, 25 years later, along with the original prototype of supraglottic airways quite a few numbers of different devices exist that can be used to secure the airway "above the glottis". After initially primarily marketing adult sizes many suppliers offer paediatric sizes nowadays. However, the scientific evidence in terms of superiority or at a least equality to the original LMA-Classic( of any of these airway devices must be considered insufficient except for the LMA-ProSeal™. Consequently, the routine use of these devices outside controlled clinical studies must be considered questionable. The following article aims at providing a critical appraisal of currently available supraglottic airway devices for neonates and infants. PMID:23633256

  8. Laryngeal mask airway: uses in anesthesiology.

    PubMed

    Pinosky, M

    1996-06-01

    The laryngeal mask airway (LMA), developed in 1983, is a new device to assist in the management of the pediatric and adult airway. In 1991, the Food and Drug Administration gave its approval for use of the LMA in the United States. The LMA is reusable and appears to provide cost-effective airway management in numerous situations. The LMA is simple to use, atraumatic to insert, and helpful in overcoming an obstructed airway. Its role in management of the difficult airway and the traumatic airway is still evolving. This review will introduce the LMA to the nonanesthesiologist and review for the anesthesiologist the origins of the LMA, its physical structure, the technical aspects of insertion, problems with aspiration, its role in the difficult airway, and experience with the pediatric population.

  9. Sarcoidosis of the upper and lower airways.

    PubMed

    Morgenthau, Adam S; Teirstein, Alvin S

    2011-12-01

    Sarcoidosis is a systemic granulomatous disease of undetermined etiology characterized by a variable clinical presentation and disease course. Although clinical granulomatous inflammation may occur within any organ system, more than 90% of sarcoidosis patients have lung disease. Sarcoidosis is considered an interstitial lung disease that is frequently characterized by restrictive physiologic dysfunction on pulmonary function tests. However, sarcoidosis also involves the airways (large and small), causing obstructive airways disease. It is one of a few interstitial lung diseases that affects the entire length of the respiratory tract - from the nose to the terminal bronchioles - and causes a broad spectrum of airways dysfunction. This article examines airway dysfunction in sarcoidosis. The anatomical structure of the airways is the organizational framework for our discussion. We discuss sarcoidosis involving the nose, sinuses, nasal passages, larynx, trachea, bronchi and small airways. Common complications of airways disease, such as, atelectasis, fibrosis, bullous leions, bronchiectasis, cavitary lesions and mycetomas, are also reviewed. PMID:22082167

  10. Liquid plug propagation in flexible microchannels: A small airway model

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Fujioka, H.; Bian, S.; Torisawa, Y.; Huh, D.; Takayama, S.; Grotberg, J. B.

    2009-07-01

    In the present study, we investigate the effect of wall flexibility on the plug propagation and the resulting wall stresses in small airway models with experimental measurements and numerical simulations. Experimentally, a flexible microchannel was fabricated to mimic the flexible small airways using soft lithography. Liquid plugs were generated and propagated through the microchannels. The local wall deformation is observed instantaneously during plug propagation with the maximum increasing with plug speed. The pressure drop across the plug is measured and observed to increase with plug speed, and is slightly smaller in a flexible channel compared to that in a rigid channel. A computational model is then presented to model the steady plug propagation through a flexible channel corresponding to the middle plane in the experimental device. The results show qualitative agreements with experiments on wall shapes and pressure drops and the discrepancies bring up interesting questions on current field of modeling. The flexible wall deforms inward near the plug core region, the deformation and pressure drop across the plug increase with the plug speed. The wall deformation and resulting stresses vary with different longitudinal tensions, i.e., for large wall longitudinal tension, the wall deforms slightly, which causes decreased fluid stress and stress gradients on the flexible wall comparing to that on rigid walls; however, the wall stress gradients are found to be much larger on highly deformable walls with small longitudinal tensions. Therefore, in diseases such as emphysema, with more deformable airways, there is a high possibility of induced injuries on lining cells along the airways because of larger wall stresses and stress gradients.

  11. Acute exposure to hair bleach causes airway hyperresponsiveness in a rabbit model.

    PubMed

    Mensing, T; Marek, W; Raulf-Heimsoth, M; Baur, X

    1998-12-01

    Ammonium persulphate (APS) and hydrogen peroxide (H2O2) are used as oxidants in many industrial processes and are the main constituents of standard hair bleaching products. In a previous study, it was demonstrated that aerosols of APS induce alterations in airway responsiveness. The present study examined whether exposure for 4 h to a hair bleach composition (containing APS, potassium persulphate and H2O2) or H2O2 could induce airway hyperresponsiveness and/or an obstructive ventilation pattern in a rabbit model. Exposure to the aerosols altered neither baseline airway resistance, dynamic elastance, slope of inspiratory pressure generation nor arterial blood pressure and blood gas measurements. Similarly to APS, hair bleach aerosols containing > or =10.9 mg x m(-3) persulphate (ammonium and potassium salt) in air and > or =1.36 mg x m(-3) H2O2 in air caused airway hyperresponsiveness to acetylcholine after 4 h of exposure. Aerosolized H2O2 (> or =37 mg x m(-3) in air) did not influence airway responsiveness to acetylcholine. The results demonstrate that hair bleaching products containing persulphates dissolved in H2O2 cause airway hyperresponsiveness to acetylcholine in rabbits.

  12. Acute exposure to hair bleach causes airway hyperresponsiveness in a rabbit model.

    PubMed

    Mensing, T; Marek, W; Raulf-Heimsoth, M; Baur, X

    1998-12-01

    Ammonium persulphate (APS) and hydrogen peroxide (H2O2) are used as oxidants in many industrial processes and are the main constituents of standard hair bleaching products. In a previous study, it was demonstrated that aerosols of APS induce alterations in airway responsiveness. The present study examined whether exposure for 4 h to a hair bleach composition (containing APS, potassium persulphate and H2O2) or H2O2 could induce airway hyperresponsiveness and/or an obstructive ventilation pattern in a rabbit model. Exposure to the aerosols altered neither baseline airway resistance, dynamic elastance, slope of inspiratory pressure generation nor arterial blood pressure and blood gas measurements. Similarly to APS, hair bleach aerosols containing > or =10.9 mg x m(-3) persulphate (ammonium and potassium salt) in air and > or =1.36 mg x m(-3) H2O2 in air caused airway hyperresponsiveness to acetylcholine after 4 h of exposure. Aerosolized H2O2 (> or =37 mg x m(-3) in air) did not influence airway responsiveness to acetylcholine. The results demonstrate that hair bleaching products containing persulphates dissolved in H2O2 cause airway hyperresponsiveness to acetylcholine in rabbits. PMID:9877493

  13. Application of the laryngeal mask airway for anesthesia in three chimpanzees and one gibbon.

    PubMed

    Johnson, Jacob A; Atkins, Adrienne L; Heard, Darryl J

    2010-09-01

    Three pediatric chimpanzees and one pediatric gibbon were anesthetized for routine physical examination. Anesthesia was maintained with inhalant delivered via a laryngeal mask airway (LMA). The LMA was easy to insert, provided adequate control of the airway for ventilation, and caused no tracheal stimulation. No complications were observed. As compared with a face mask, the LMA has the advantage of a more secure airway; the ability to effectively ventilate the patient; less dead space, which leads to lower rebreathing of carbon dioxide; and less exposure of personnel to waste gases. As compared with an endotracheal tube, the LMA causes less airway trauma, is easier to place, and is less stimulating to the patient. The LMA should be considered for use in fasted non-human primates presented for procedures lasting less than 60 min where high peak inspiratory pressures are not needed.

  14. Integrated care pathways for airway diseases (AIRWAYS-ICPs).

    PubMed

    Bousquet, J; Addis, A; Adcock, I; Agache, I; Agusti, A; Alonso, A; Annesi-Maesano, I; Anto, J M; Bachert, C; Baena-Cagnani, C E; Bai, C; Baigenzhin, A; Barbara, C; Barnes, P J; Bateman, E D; Beck, L; Bedbrook, A; Bel, E H; Benezet, O; Bennoor, K S; Benson, M; Bernabeu-Wittel, M; Bewick, M; Bindslev-Jensen, C; Blain, H; Blasi, F; Bonini, M; Bonini, S; Boulet, L P; Bourdin, A; Bourret, R; Bousquet, P J; Brightling, C E; Briggs, A; Brozek, J; Buhl, R; Bush, A; Caimmi, D; Calderon, M; Calverley, P; Camargos, P A; Camuzat, T; Canonica, G W; Carlsen, K H; Casale, T B; Cazzola, M; Cepeda Sarabia, A M; Cesario, A; Chen, Y Z; Chkhartishvili, E; Chavannes, N H; Chiron, R; Chuchalin, A; Chung, K F; Cox, L; Crooks, G; Crooks, M G; Cruz, A A; Custovic, A; Dahl, R; Dahlen, S E; De Blay, F; Dedeu, T; Deleanu, D; Demoly, P; Devillier, P; Didier, A; Dinh-Xuan, A T; Djukanovic, R; Dokic, D; Douagui, H; Dubakiene, R; Eglin, S; Elliot, F; Emuzyte, R; Fabbri, L; Fink Wagner, A; Fletcher, M; Fokkens, W J; Fonseca, J; Franco, A; Frith, P; Furber, A; Gaga, M; Garcés, J; Garcia-Aymerich, J; Gamkrelidze, A; Gonzales-Diaz, S; Gouzi, F; Guzmán, M A; Haahtela, T; Harrison, D; Hayot, M; Heaney, L G; Heinrich, J; Hellings, P W; Hooper, J; Humbert, M; Hyland, M; Iaccarino, G; Jakovenko, D; Jardim, J R; Jeandel, C; Jenkins, C; Johnston, S L; Jonquet, O; Joos, G; Jung, K S; Kalayci, O; Karunanithi, S; Keil, T; Khaltaev, N; Kolek, V; Kowalski, M L; Kull, I; Kuna, P; Kvedariene, V; Le, L T; Lodrup Carlsen, K C; Louis, R; MacNee, W; Mair, A; Majer, I; Manning, P; de Manuel Keenoy, E; Masjedi, M R; Melen, E; Melo-Gomes, E; Menzies-Gow, A; Mercier, G; Mercier, J; Michel, J P; Miculinic, N; Mihaltan, F; Milenkovic, B; Molimard, M; Momas, I; Montilla-Santana, A; Morais-Almeida, M; Morgan, M; N'Diaye, M; Nafti, S; Nekam, K; Neou, A; Nicod, L; O'Hehir, R; Ohta, K; Paggiaro, P; Palkonen, S; Palmer, S; Papadopoulos, N G; Papi, A; Passalacqua, G; Pavord, I; Pigearias, B; Plavec, D; Postma, D S; Price, D; Rabe, K F; Radier Pontal, F; Redon, J; Rennard, S; Roberts, J; Robine, J M; Roca, J; Roche, N; Rodenas, F; Roggeri, A; Rolland, C; Rosado-Pinto, J; Ryan, D; Samolinski, B; Sanchez-Borges, M; Schünemann, H J; Sheikh, A; Shields, M; Siafakas, N; Sibille, Y; Similowski, T; Small, I; Sola-Morales, O; Sooronbaev, T; Stelmach, R; Sterk, P J; Stiris, T; Sud, P; Tellier, V; To, T; Todo-Bom, A; Triggiani, M; Valenta, R; Valero, A L; Valiulis, A; Valovirta, E; Van Ganse, E; Vandenplas, O; Vasankari, T; Vestbo, J; Vezzani, G; Viegi, G; Visier, L; Vogelmeier, C; Vontetsianos, T; Wagstaff, R; Wahn, U; Wallaert, B; Whalley, B; Wickman, M; Williams, D M; Wilson, N; Yawn, B P; Yiallouros, P K; Yorgancioglu, A; Yusuf, O M; Zar, H J; Zhong, N; Zidarn, M; Zuberbier, T

    2014-08-01

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will add value to existing public health knowledge by: 1) proposing a common framework of care pathways for chronic respiratory diseases, which will facilitate comparability and trans-national initiatives; 2) informing cost-effective policy development, strengthening in particular those on smoking and environmental exposure; 3) aiding risk stratification in chronic disease patients, using a common strategy; 4) having a significant impact on the health of citizens in the short term (reduction of morbidity, improvement of education in children and of work in adults) and in the long-term (healthy ageing); 5) proposing a common simulation tool to assist physicians; and 6) ultimately reducing the healthcare burden (emergency visits, avoidable hospitalisations, disability and costs) while improving quality of life. In the longer term, the incidence of disease may be reduced by innovative prevention strategies. AIRWAYSICPs was initiated by Area 5 of the Action Plan B3 of the European Innovation Partnership on Active and Healthy Ageing. All stakeholders are involved (health and social care, patients, and policy makers). PMID:24925919

  15. UPPER AIRWAY BLOCKS FOR AWAKE DIFFICULT AIRWAY MANAGEMENT.

    PubMed

    Pintaric, Tatjana Stopar

    2016-03-01

    Airway anesthesia is pivotal for successful awake intubation provided either topically or by blocks. Airway blocks are considered technically more difficult to perform and carry a higher risk of complications. However, in experienced hands, they can be useful as they provide excellent intubating conditions. For complete upper airway anesthesia, bilateral glossopharyngeal and superior laryngeal nerve blocks with translaryngeal injection are required. Superior laryngeal nerve block and translaryngeal injection can be performed easily, safely and with a high success rate in patients with normal anatomy. In those with difficult landmarks, ultrasound can be of assistance. For the superior laryngeal nerve block, other targets than the nerve itself must be established to make the technique consistently successful, easy to teach, learn and perform. The same applies to the translaryngeal injection, where the use of ultrasound is necessary for correct midline identification. Intraoral glossopharyngeal nerve block is also safe and easy to perform, but associated with long lasting discomfort. Bilateral extraoral peristyloid approach should be discouraged since inadvertent blocks of the closely adjacent vagus nerve cannot be prevented in this location. A safe and easy method of blocking the distal portions of the glossopharyngeal nerve for awake intubation is therefore required. PMID:27276778

  16. Integrated care pathways for airway diseases (AIRWAYS-ICPs).

    PubMed

    Bousquet, J; Addis, A; Adcock, I; Agache, I; Agusti, A; Alonso, A; Annesi-Maesano, I; Anto, J M; Bachert, C; Baena-Cagnani, C E; Bai, C; Baigenzhin, A; Barbara, C; Barnes, P J; Bateman, E D; Beck, L; Bedbrook, A; Bel, E H; Benezet, O; Bennoor, K S; Benson, M; Bernabeu-Wittel, M; Bewick, M; Bindslev-Jensen, C; Blain, H; Blasi, F; Bonini, M; Bonini, S; Boulet, L P; Bourdin, A; Bourret, R; Bousquet, P J; Brightling, C E; Briggs, A; Brozek, J; Buhl, R; Bush, A; Caimmi, D; Calderon, M; Calverley, P; Camargos, P A; Camuzat, T; Canonica, G W; Carlsen, K H; Casale, T B; Cazzola, M; Cepeda Sarabia, A M; Cesario, A; Chen, Y Z; Chkhartishvili, E; Chavannes, N H; Chiron, R; Chuchalin, A; Chung, K F; Cox, L; Crooks, G; Crooks, M G; Cruz, A A; Custovic, A; Dahl, R; Dahlen, S E; De Blay, F; Dedeu, T; Deleanu, D; Demoly, P; Devillier, P; Didier, A; Dinh-Xuan, A T; Djukanovic, R; Dokic, D; Douagui, H; Dubakiene, R; Eglin, S; Elliot, F; Emuzyte, R; Fabbri, L; Fink Wagner, A; Fletcher, M; Fokkens, W J; Fonseca, J; Franco, A; Frith, P; Furber, A; Gaga, M; Garcés, J; Garcia-Aymerich, J; Gamkrelidze, A; Gonzales-Diaz, S; Gouzi, F; Guzmán, M A; Haahtela, T; Harrison, D; Hayot, M; Heaney, L G; Heinrich, J; Hellings, P W; Hooper, J; Humbert, M; Hyland, M; Iaccarino, G; Jakovenko, D; Jardim, J R; Jeandel, C; Jenkins, C; Johnston, S L; Jonquet, O; Joos, G; Jung, K S; Kalayci, O; Karunanithi, S; Keil, T; Khaltaev, N; Kolek, V; Kowalski, M L; Kull, I; Kuna, P; Kvedariene, V; Le, L T; Lodrup Carlsen, K C; Louis, R; MacNee, W; Mair, A; Majer, I; Manning, P; de Manuel Keenoy, E; Masjedi, M R; Melen, E; Melo-Gomes, E; Menzies-Gow, A; Mercier, G; Mercier, J; Michel, J P; Miculinic, N; Mihaltan, F; Milenkovic, B; Molimard, M; Momas, I; Montilla-Santana, A; Morais-Almeida, M; Morgan, M; N'Diaye, M; Nafti, S; Nekam, K; Neou, A; Nicod, L; O'Hehir, R; Ohta, K; Paggiaro, P; Palkonen, S; Palmer, S; Papadopoulos, N G; Papi, A; Passalacqua, G; Pavord, I; Pigearias, B; Plavec, D; Postma, D S; Price, D; Rabe, K F; Radier Pontal, F; Redon, J; Rennard, S; Roberts, J; Robine, J M; Roca, J; Roche, N; Rodenas, F; Roggeri, A; Rolland, C; Rosado-Pinto, J; Ryan, D; Samolinski, B; Sanchez-Borges, M; Schünemann, H J; Sheikh, A; Shields, M; Siafakas, N; Sibille, Y; Similowski, T; Small, I; Sola-Morales, O; Sooronbaev, T; Stelmach, R; Sterk, P J; Stiris, T; Sud, P; Tellier, V; To, T; Todo-Bom, A; Triggiani, M; Valenta, R; Valero, A L; Valiulis, A; Valovirta, E; Van Ganse, E; Vandenplas, O; Vasankari, T; Vestbo, J; Vezzani, G; Viegi, G; Visier, L; Vogelmeier, C; Vontetsianos, T; Wagstaff, R; Wahn, U; Wallaert, B; Whalley, B; Wickman, M; Williams, D M; Wilson, N; Yawn, B P; Yiallouros, P K; Yorgancioglu, A; Yusuf, O M; Zar, H J; Zhong, N; Zidarn, M; Zuberbier, T

    2014-08-01

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will add value to existing public health knowledge by: 1) proposing a common framework of care pathways for chronic respiratory diseases, which will facilitate comparability and trans-national initiatives; 2) informing cost-effective policy development, strengthening in particular those on smoking and environmental exposure; 3) aiding risk stratification in chronic disease patients, using a common strategy; 4) having a significant impact on the health of citizens in the short term (reduction of morbidity, improvement of education in children and of work in adults) and in the long-term (healthy ageing); 5) proposing a common simulation tool to assist physicians; and 6) ultimately reducing the healthcare burden (emergency visits, avoidable hospitalisations, disability and costs) while improving quality of life. In the longer term, the incidence of disease may be reduced by innovative prevention strategies. AIRWAYSICPs was initiated by Area 5 of the Action Plan B3 of the European Innovation Partnership on Active and Healthy Ageing. All stakeholders are involved (health and social care, patients, and policy makers).

  17. Comparison of laryngeal mask airway use with endotracheal intubation during anesthesia of western lowland gorillas (Gorilla gorilla gorilla).

    PubMed

    Cerveny, Shannon N; D'Agostino, Jennifer J; Davis, Michelle R; Payton, Mark E

    2012-12-01

    The laryngeal mask airway is an alternative to endotracheal intubation that achieves control of the airway by creating a seal around the larynx with an inflatable cuff. This study compared use of the laryngeal mask airway with endotracheal intubation in anesthetized western lowland gorillas (Gorilla gorilla gorilla). Eight adult gorillas were immobilized for routine and diagnostic purposes for a total of nine anesthetic events. During each anesthetic event, gorillas were either intubated (n = 4; group A) or fitted with a laryngeal mask airway (n= 5; group B). Time required to place each airway device, physiologic parameters, and arterial blood gas were measured and compared between the two groups. There were no significant differences between the two groups for time required to place airway device, heart rate, hemoglobin oxygen saturation, end-tidal carbon dioxide, arterial partial pressure of carbon dioxide, or arterial pH between the two groups. Mean arterial partial pressure of oxygen was significantly greater in group B, 15 (group A: 94 +/- 44 mm Hg; group B: 408 +/- 36 mm Hg; P= 0.0025) and 45 (group A: 104 +/- 21 mm Hg; group B: 407 +/- 77 mm Hg; P = 0.0026) min after airway device placement. Mean respiratory rate was significantly greater in group A at multiple time points. Mean arterial pressure (group A: 129 +/- 16 mm Hg; group B: 60 +/- 8 mm Hg) and diastolic blood pressure (group A: 115 +/- 21 mm Hg; group B: 36 +/- 10 mm Hg) were significantly greater in group A at the time of airway device placement. The laryngeal mask airway maintained oxygenation and ventilation effectively in all gorillas and is a useful alternative to endotracheal intubation in western lowland gorillas.

  18. Airway management in cervical spine injury

    PubMed Central

    Austin, Naola; Krishnamoorthy, Vijay; Dagal, Arman

    2014-01-01

    To minimize risk of spinal cord injury, airway management providers must understand the anatomic and functional relationship between the airway, cervical column, and spinal cord. Patients with known or suspected cervical spine injury may require emergent intubation for airway protection and ventilatory support or elective intubation for surgery with or without rigid neck stabilization (i.e., halo). To provide safe and efficient care in these patients, practitioners must identify high-risk patients, be comfortable with available methods of airway adjuncts, and know how airway maneuvers, neck stabilization, and positioning affect the cervical spine. This review discusses the risks and benefits of various airway management strategies as well as specific concerns that affect patients with known or suspected cervical spine injury. PMID:24741498

  19. Computational modeling of unsteady surfactant-laden liquid plug propagation in neonatal airways

    NASA Astrophysics Data System (ADS)

    Olgac, Ufuk; Muradoglu, Metin

    2013-07-01

    Surfactant-free and surfactant-laden liquid plug propagation in neonatal airways in various generations representing the upper and lower airways are investigated computationally using a finite-difference/front-tracking method. Emphasis is placed on the unsteady surfactant-laden plug propagation as a model for Surfactant Replacement Therapy (SRT) and airway reopening. The numerical method is designed to solve the evolution equations of the interfacial and bulk surfactant concentrations coupled with the incompressible Navier-Stokes equations. Available experimental data for surfactant Survanta are used to relate surface tension coefficient to surfactant concentration at the interface. It is found that, for the surfactant-free case, the trailing film thickness is in good agreement with Taylor's law for plugs with plug length greater than the airway width. Mechanical stresses that could be injurious to epithelial cells such as pressure and shear stress and their gradients are maximized on the front and rear menisci with increasing magnitudes in the lower generations. These mechanical stresses, especially pressure and pressure gradient, are diminished with the introduction of surfactants. Surfactant is absorbed onto the trailing film and thickens it, eventually leading to either plug rupture or, if totally consumed prior to rupture, to steadily propagating plug. In the upper airways, initially small plugs rupture rapidly and plugs with comparable initial plug length with the airway width persist and propagate steadily. For a more effective SRT treatment, we recommend utilization of plugs with initial plug length greater than the airway width. Increasing surfactant strength or increasing the initially instilled surfactant concentration is found to be ineffective.

  20. A randomised trial to compare i-gel and ProSeal™ laryngeal mask airway for airway management in paediatric patients

    PubMed Central

    Nirupa, R; Gombar, Satinder; Ahuja, Vanita; Sharma, Preeti

    2016-01-01

    Background and Aims: i-gel™ is a newer supraglottic airway device with a unique non-inflatable cuff. We aimed to compare i-gel™ with ProSeal™ laryngeal mask airway (PLMA™) in children scheduled for surgery under general anaesthesia (GA) with controlled ventilation. Methods: This prospective, randomised controlled study was conducted in 100 surgical patients, aged 2–6 years of American Society of Anesthesiologists Physical Status I–II scheduled under GA. Patients were randomly allocated to receive either size 2 i-gel™ or PLMA™ as an airway device. The primary aim was oropharyngeal leak pressure assessed at 5 min following correct placement of the device. Secondary outcomes measured included number of attempts, ease of insertion, time of insertion, quality of initial airway, fibre-optic grading and effects on pulmonary mechanics. Statistical analysis was done using paired t-test and Chi-square test. Results: The demographic data were similar in both the groups. The oropharyngeal leak pressure in the i-gel™ group was 29.5 ± 2.5 cmH2 O as compared to 26.1 ± 3.8 cmH2 O in PLMA™ group (P = 0.002). The time taken for successful insertion in PLMA™ was longer as compared to i-gel (12.4 ± 2.7 vs. 10.2 ± 1.9 s, P = 0.007). The quality of initial airway was superior with i-gel™. The number of attempts, ease of insertion of supraglottic device, insertion of orogastric tube and pulmonary mechanics were similar in both the groups. Conclusion: Size 2 i-gel™ exhibited superior oropharyngeal leak pressure and quality of airway in paediatric patients with controlled ventilation as compared to PLMA™ although the pulmonary mechanics were similar. PMID:27761035

  1. Anatomic Optical Coherence Tomography of Upper Airways

    NASA Astrophysics Data System (ADS)

    Chin Loy, Anthony; Jing, Joseph; Zhang, Jun; Wang, Yong; Elghobashi, Said; Chen, Zhongping; Wong, Brian J. F.

    The upper airway is a complex and intricate system responsible for respiration, phonation, and deglutition. Obstruction of the upper airways afflicts an estimated 12-18 million Americans. Pharyngeal size and shape are important factors in the pathogenesis of airway obstructions. In addition, nocturnal loss in pharyngeal muscular tone combined with high pharyngeal resistance can lead to collapse of the airway and periodic partial or complete upper airway obstruction. Anatomical optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images of the airway lumen without the use of ionizing radiation. In this chapter we describe the methods behind endoscopic OCT imaging and processing to generate full three dimensional anatomical models of the human airway which can be used in conjunction with numerical simulation methods to assess areas of airway obstruction. Combining this structural information with flow dynamic simulations, we can better estimate the site and causes of airway obstruction and better select and design surgery for patients with obstructive sleep apnea.

  2. AIRWAY VISUALIZATION: EYES SEE WHAT MIND KNOWS.

    PubMed

    Sorbello, Massimiliano; Frova, Giulio; Zdravković, Ivana

    2016-03-01

    Airway management is basic for anesthesia practice, and sometimes it can represent a really dramatic scenario for both the patient and the physicians. Laryngoscopy has been the gold standard of airway visualization for more than 60 years, showing its limitations and failure rates with time. New technology has made available an opportunity to move the physician's eye inside patient airways thanks to video laryngoscopy and video assisted airway management technique. Undoubtedly, we have entered a new era of high resolution airway visualization and different approach in airway instrumentation. Nevertheless, each new technology needs time to be tested and considered reliable, and pitfalls and limitations may come out with careful and long lasting analysis, so it is probably not the right time yet to promote video assisted approach as a new gold standard for airway visualization, despite the fact that it certainly offers some new prospects. In any case, whatever the visualization approach, no patient dies because of missed airway visualization or failed intubation, but due to failed ventilation, which remains without doubt the gold standard of any patient safety goal and airway management technique.

  3. Method for 3D Airway Topology Extraction

    PubMed Central

    Grothausmann, Roman; Kellner, Manuela; Heidrich, Marko; Lorbeer, Raoul-Amadeus; Ripken, Tammo; Meyer, Heiko; Kuehnel, Mark P.; Ochs, Matthias; Rosenhahn, Bodo

    2015-01-01

    In lungs the number of conducting airway generations as well as bifurcation patterns varies across species and shows specific characteristics relating to illnesses or gene variations. A method to characterize the topology of the mouse airway tree using scanning laser optical tomography (SLOT) tomograms is presented in this paper. It is used to test discrimination between two types of mice based on detected differences in their conducting airway pattern. Based on segmentations of the airways in these tomograms, the main spanning tree of the volume skeleton is computed. The resulting graph structure is used to distinguish between wild type and surfactant protein (SP-D) deficient knock-out mice. PMID:25767561

  4. Sequential Stenting for Extensive Malignant Airway Stenosis

    PubMed Central

    Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Tei, Keiko; Yamamoto, Ryoji

    2014-01-01

    Purpose: Malignant airway stenosis extending from the bronchial bifurcation to the lower lobar orifice was treated with airway stenting. We herein examine the effectiveness of airway stenting for extensive malignant airway stenosis. Methods: Twelve patients with extensive malignant airway stenosis underwent placement of a silicone Dumon Y stent (Novatech, La Ciotat, France) at the tracheal bifurcation and a metallic Spiral Z-stent (Medico’s Hirata, Osaka, Japan) at either distal side of the Y stent. We retrospectively analyzed the therapeutic efficacy of the sequential placement of these silicone and metallic stents in these 12 patients. Results: The primary disease was lung cancer in eight patients, breast cancer in two patients, tracheal cancer in one patient, and thyroid cancer in one patient. The median survival period after airway stent placement was 46 days. The Hugh–Jones classification and performance status improved in nine patients after airway stenting. One patient had prolonged hemoptysis and died of respiratory tract hemorrhage 15 days after the treatment. Conclusion: Because the initial disease was advanced and aggressive, the prognosis after sequential airway stent placement was significantly poor. However, because respiratory distress decreased after the treatment in most patients, this treatment may be acceptable for selected patients with extensive malignant airway stenosis. PMID:25273272

  5. Physical principle of airway design in human lungs

    NASA Astrophysics Data System (ADS)

    Park, Keunhwan; Son, Taeho; Kim, Wonjung; Kim, Ho-Young

    2014-11-01

    From an engineering perspective, lungs are natural microfluidic devices that extract oxygen from air. In the bronchial tree, airways branch by dichotomy with a systematic reduction of their diameters. It is generally accepted that in conducting airways, which air passes on the way to the acinar airways from the atmosphere, the reduction ratio of diameter is closely related to the minimization of viscous dissipation. Such a principle is formulated as the Hess-Murray law. However, in acinar airways, where oxygen transfer to alveolae occurs, the diameter reduction with progressive generations is more moderate than in conducting airways. Noting that the dominant transfer mechanism in acinar airways is diffusion rather than advection, unlike conducting airways, we construct a mathematical model for oxygen transfer through a series of acinar airways. Our model allows us to predict the optimal airway reduction ratio that maximizes the oxygen transfer in a finite airway volume, thereby rationalizing the observed airway reduction ratio in acinar airways.

  6. Comparison of I-gel with Classic Laryngeal Mask Airway Regarding the Ease of Use and Clinical Performance

    PubMed Central

    Arı, Dilek Erdoğan; Ar, Arzu Yıldırım; Karip, Ceren Şanlı; Siyahkoç, İncifer; Arslan, Ahmet Hakan; Akgün, Fatma Nur

    2015-01-01

    Objective I-gel is a new supraglottic airway device without an inflatable cuff. We aimed to compare I-gel and the classic laryngeal mask airway (LMA) regarding the ease of use and clinical performance in Turkish population. Methods Fifty American Society of Anesthesiologists (ASA) I–II patients were randomly allocated into two groups: Group I-gel and Group LMA. Insertion time and success in first attempt were recorded. Peak, plato and mean airway pressures, EtCO2, airway compliance and leak volume were periodically recorded during the operation. The presence of blood on device removal and postoperative sore throat were also assessed. Results The device insertion time in Group I-gel was shorter than that in Group LMA (21.00±4.15 vs. 30.40±12.17 s, p=0.001). The success rate in first attempt, peak, plato and mean airway pressures, EtCO2 and airway compliance did not differ between the groups. The leak volume was lower in Group I-gel 5 and 45 min after insertion (p=0.041 and p=0.027). The presence of blood on device removal and postoperative sore throat were similar in both groups. Conclusion I-gel may be a more advantageous supraglottic airway device compared with LMA. PMID:27366518

  7. Computational fluid dynamics modeling of the upper airway of children with obstructive sleep apnea syndrome in steady flow.

    PubMed

    Xu, Chun; Sin, SangHun; McDonough, Joseph M; Udupa, Jayaram K; Guez, Allon; Arens, Raanan; Wootton, David M

    2006-01-01

    Computational fluid dynamic (CFD) analysis was used to model the effect of airway geometry on internal pressure in the upper airway of three children with obstructive sleep apnea syndrome (OSAS), and three controls. Model geometry was reconstructed from magnetic resonance images obtained during quiet tidal breathing, meshed with an unstructured grid, and solved at normative peak resting flow. The unsteady Reynolds-averaged Navier-Stokes equations were solved with steady flow boundary conditions in inspiration and expiration, using a two-equation low-Reynolds number turbulence model. Model results were validated using an in-vitro scale model, unsteady flow simulation, and reported nasal resistance measurements in children. Pharynx pressure drop strongly correlated to airway area restriction. Inspiratory pressure drop was primarily proportional to the square of flow, consistent with pressure losses due to convective acceleration caused by area restriction. On inspiration, in OSAS pressure drop occurred primarily between the choanae and the region where the adenoids overlap the tonsils (overlap region) due to airway narrowing, rather than in the nasal passages; in controls the majority of pressure drop was in the nasal passages. On expiration, in OSAS the majority of pressure drop occurred between the oropharynx (posterior to the tongue) and overlap region, and local minimum pressure in the overlap region was near atmospheric due to pressure recovery in the anterior nasopharynx. The results suggest that pharyngeal airway shape in children with OSAS significantly affects internal pressure distribution compared to nasal resistance. The model may also help explain regional dynamic airway narrowing during expiration. PMID:16098533

  8. Effect of ozone exposure on antigen-induced airway hyperresponsiveness in guinea pigs

    SciTech Connect

    Vargas, M.H.; Segura, P.; Campos, M.G.; Hong, E.; Montano, L.M.

    1994-12-31

    Airway hyperresponsiveness can be induced by several stimuli including antigen and ozone, both of which may be present in the air of polluted cities. Though the effect of ozone on the bronchoconstrictor response to antigen has been well described, the combined effect of these stimuli on airway hyperresponsiveness has not yet been studied. Sensitized guinea pigs with or without ozone exposure for 1 h at 3 ppm, 18 h prior to study, were challenged with a dose-response curve to histamine (0.01-1.8 {mu}g/kg, iv), and then by a second histamine dose-response curve 1 h later. Airway responses were measured as the increase in pulmonary insufflation pressure. In sensitized guinea pigs, the histamine ED50 significantly decreased after antigen challenge, demonstrating the development of airway hyperresponsiveness. Sensitized guinea pigs exposed to ozone showed airway hyperresponsiveness to histamine when compared with nonexposed animals, and such hyperresponsiveness was further enhanced after antigen challenge. We conclude that in this guinea pig model of acute allergic bronchoconstriction both antigen challenge and ozone induce airway hyperresponsiveness, while ozone exposure does not modify the development of antigen-induced hyperresponsiveness. 25 refs., 1 fig., 1 tab.

  9. Design of a new controller to treat the obstructive sleep apnea

    NASA Astrophysics Data System (ADS)

    Netzel, Thomas

    2002-06-01

    The obstructive sleep apnoea (OSA) is a sleep related breathing disorder caused by a relaxation of the upper airway structure during the sleep that leads to a complete closure of the upper airway. The most successful therapy is the nasal continuous positive airway pressure (nCPAP) treatment that keeps the airway opened. More recent devices use an automatic adaptation of the applied pressure. Either the forced oscillation technique (FOT) or the evaluation of the inspiration flow contour are used to evaluate the severity of obstructions. Both methods have disadvantages that may lead to wrong applied pressures. Based on the precise measurement of airflow and mask pressure during nCPAP with a Weinmann SOMNOsmart and additional polysomnography a new parameter set is presented that uses the advantage of both methods to detect the obstructive sleep apnoea. To evaluate the applicability of this parameter set to control Auto-nCPAP-devices a fuzzy-controller is designed under MATLAB/Simulink using an A/D-D/A-converter to control the blower of the SOMNOsmart during Auto-nCPAP-therapy. Obstructive events are detected and treated with a rise of nCPAP-pressure depending on the inspiratory flow requirement. The pressure is lowered after the end of flow limited phases. Although temporary low pressures no oxygen desaturation is recognized by the pulse oxymeter.

  10. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  11. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  12. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  13. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  14. 21 CFR 868.1750 - Pressure plethysmograph.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pressure plethysmograph. 868.1750 Section 868.1750...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1750 Pressure plethysmograph. (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and...

  15. Cardiovascular effects of methacholine-induced airway obstruction in man.

    PubMed

    Sharman, J E; Johns, D P; Marrone, J; Walls, J; Wood-Baker, R; Walters, E H

    2014-06-01

    Cardiovascular disease is the most frequent cause of death in people with chronic respiratory disease. The cause of this association has been attributed to airway obstruction leading to cardiovascular dysfunction (increased central blood pressure (BP) and aortic stiffness). However, this has never been experimentally tested. Methacholine is routinely used to stimulate airway function changes that mimic airway pathology. This study aimed to determine the cardiovascular effects of methacholine-induced airway obstruction. Fifteen healthy young adults (aged 22.9±2.5 years; 4 male; mean±S.D.) underwent a bronchial challenge test (randomized, blinded, cross-over design) in which they received nebulized methacholine inhalation in serially increasing concentrations (from 0.39 to 25 mg/ml) or saline (0.9%; control) on two separate days. Bronchoconstriction was assessed by forced expiratory volume at one second (FEV1) and cardiovascular effects by augmentation index, brachial BP, central BP, heart rate and aortic stiffness. Methacholine significantly decreased FEV1 from baseline to peak inhaled concentration compared with saline (-0.48±0.34 vs. -0.07±0.16 L; p<0.001), but there was no between-group change in augmentation index (1.6±7.0 vs. 3.7±10.2% p=0.49), brachial systolic BP (-3.3±7.6 vs. -4.7±5.7 mmHg; p=0.59), central systolic BP (-1.1±5.2 vs. -0.3±5.5 mmHg; p=0.73), heart rate (0.4±7.1 vs. -0.8±6.6 bpm; p=0.45) or aortic stiffness (0.2±1.3 vs. 0.8±1.8 m/s; p=0.20; n=12). Thus, methacholine induced airway obstruction does not acutely change brachial BP or central haemodynamics. This finding refutes the notion that airway obstruction per se leads to cardiovascular dysfunction, at least in healthy individuals in the acute setting.

  16. Effects of Race on Upper Airway Dynamic Function During Sleep in Children

    PubMed Central

    Pinto, Swaroop; Huang, Jingtao; Tapia, Ignacio; Karamessinis, Laurie; Pepe, Michelle; Gallagher, Paul R.; Bradford, Ruth; Nixon, Tomas; Lee, Ngoon-Yin; Marcus, Carole L.

    2011-01-01

    Study Objective: Studies in adults and children have shown that African American race is a risk factor for the obstructive sleep apnea syndrome (OSAS). Therefore, we hypothesized that non-obese, non-snoring African American children would have a more collapsible upper airway during sleep than age-, gender-, and size-matched Caucasians. Design: Upper airway dynamic function was measured during sleep in normal African American and Caucasian children. Setting: Sleep laboratory. Patients or Participants: 56 normal children between the ages of 8-18 years. Interventions: Pressure-flow relationships were measured during NREM sleep. Nasal pressure was decreased to subatmospheric levels, using previously described techniques that resulted in an activated and relatively hypotonic upper airway. Measurements and Results: The activated and hypotonic critical pressures (Pcrit) were -25 (-25, -3) (median, range) and -19 (-25, -3) for African Americans, and -25 (-25, -4) and -25 (-25.0, -4) cm H2O, respectively, for Caucasians. The slopes of the pressure-flow response (SPF) under activated and hypotonic conditions for African Americans were 10 (-9, 46) and 13 (-20, 46), and for Caucasians 9 (-9, 64) and 8 (-5, 54) mL/s/cm H2O, respectively. There were no significant differences between groups for Pcrit or SPF under either activated or hypotonic conditions. Conclusion: Upper airway collapsibility was similar in asymptomatic, non-obese African American and Caucasian children. Differences in upper airway characteristics and neuromotor function cannot explain the increased prevalence of OSAS in African American children. Citation: Pinto S; Huang J; Tapia I; Karamessinis L; Pepe M; Gallagher PR; Bradford R; Nixon T; Lee NY; Marcus CL. Effects of race on upper airway dynamic function during sleep in children. SLEEP 2011;34(4):495-501. PMID:21461328

  17. Airway hyperresponsiveness in elite athletes.

    PubMed

    Langdeau, J B; Turcotte, H; Bowie, D M; Jobin, J; Desgagné, P; Boulet, L P

    2000-05-01

    It has been suggested that high-level training could contribute to the development of airway hyperresponsiveness (AHR), but the comparative effects of different sports on airway function remains to be determined. We evaluated 150 nonsmoking volunteers 18 to 55 yr of age; 100 athletes divided into four subgroups of 25 subjects each according to the predominant estimated hydrocaloric characteristic of ambient air inhaled during training: dry air (DA), cold air (CA), humid air (HA) and a mixture of dry and humid air (MA), and 50 sedentary subjects. Each subject had a respiratory questionnaire, a methacholine challenge, allergy skin-prick tests, and heart rate variability recording for evaluation of parasympathetic tone. The athletes had a 49% prevalence of AHR (PC(20) < 16 mg/ml), with a mean PC(20) of 16.9 mg/ml, compared with 28% (PC(20): 35.4) in sedentary subjects (p = 0.009). The prevalence (%) of AHR and mean PC(20) (mg/ml) varied as followed in the four subgroups of athletes: DA: 32% and 30.9; CA: 52% and 15.8; HA: 76% and 7.3; and MA: 32% and 21.5 (p = 0.002). The estimated parasympathetic tone was higher in athletes (p < 0.001), but this parameter showed only a weak correlation with PC(20) (r = -0.17, p = 0.04). This study has shown a significantly higher prevalence of AHR in athletes than in the control group because of the higher prevalence in the CA and HA groups. Parasympathetic activity may act as modulator of airway responsiveness, but the increased prevalence of AHR in our athlete population may be related to the type and possibly the content of inhaled air during training.

  18. Modeled velopharyngeal orifice area prediction during simulated stop consonant production in the presence of increased nasal airway resistance.

    PubMed

    Smith, B E; Maddox, C M; Kostinski, A B

    1985-07-01

    This project examined modeled velopharyngeal orifice area estimation under conditions simulating voiceless stop consonant production in the presence of nasal airway obstruction. The results indicated that accurate estimates of velopharyngeal orifice area can be obtained using Warren's hydrokinetic equation during aerodynamic events like those known to exist during speech in the presence of increased nasal airway resistance. These findings provide support for clinical and research use of Warren's pressure-flow approach to investigate velopharyngeal function during speech production.

  19. Modeled velopharyngeal orifice area prediction during simulated stop consonant production in the presence of increased nasal airway resistance.

    PubMed

    Smith, B E; Maddox, C M; Kostinski, A B

    1985-07-01

    This project examined modeled velopharyngeal orifice area estimation under conditions simulating voiceless stop consonant production in the presence of nasal airway obstruction. The results indicated that accurate estimates of velopharyngeal orifice area can be obtained using Warren's hydrokinetic equation during aerodynamic events like those known to exist during speech in the presence of increased nasal airway resistance. These findings provide support for clinical and research use of Warren's pressure-flow approach to investigate velopharyngeal function during speech production. PMID:3860307

  20. Airway smooth muscle dynamics: a common pathway of airway obstruction in asthma

    PubMed Central

    An, S.S.; Bai, T.R.; Bates, J.H.T.; Black, J.L.; Brown, R.H.; Brusasco, V.; Chitano, P.; Deng, L.; Dowell, M.; Eidelman, D.H.; Fabry, B.; Fairbank, N.J.; Ford, L.E.; Fredberg, J.J.; Gerthoffer, W.T.; Gilbert, S.H.; Gosens, R.; Gunst, S.J.; Halayko, A.J.; Ingram, R.H.; Irvin, C.G.; James, A.L.; Janssen, L.J.; King, G.G.; Knight, D.A.; Lauzon, A.M.; Lakser, O.J.; Ludwig, M.S.; Lutchen, K.R.; Maksym, G.N.; Martin, J.G.; Mauad, T.; McParland, B.E.; Mijailovich, S.M.; Mitchell, H.W.; Mitchell, R.W.; Mitzner, W.; Murphy, T.M.; Paré, P.D.; Pellegrino, R.; Sanderson, M.J.; Schellenberg, R.R.; Seow, C.Y.; Silveira, P.S.P.; Smith, P.G.; Solway, J.; Stephens, N.L.; Sterk, P.J.; Stewart, A.G.; Tang, D.D.; Tepper, R.S.; Tran, T.; Wang, L.

    2008-01-01

    Excessive airway obstruction is the cause of symptoms and abnormal lung function in asthma. As airway smooth muscle (ASM) is the effecter controlling airway calibre, it is suspected that dysfunction of ASM contributes to the pathophysiology of asthma. However, the precise role of ASM in the series of events leading to asthmatic symptoms is not clear. It is not certain whether, in asthma, there is a change in the intrinsic properties of ASM, a change in the structure and mechanical properties of the noncontractile components of the airway wall, or a change in the interdependence of the airway wall with the surrounding lung parenchyma. All these potential changes could result from acute or chronic airway inflammation and associated tissue repair and remodelling. Anti-inflammatory therapy, however, does not “cure” asthma, and airway hyperresponsiveness can persist in asthmatics, even in the absence of airway inflammation. This is perhaps because the therapy does not directly address a fundamental abnormality of asthma, that of exaggerated airway narrowing due to excessive shortening of ASM. In the present study, a central role for airway smooth muscle in the pathogenesis of airway hyperresponsiveness in asthma is explored. PMID:17470619

  1. Peripheral airways obstruction in idiopathic pulmonary artery hypertension (primary).

    PubMed

    Fernandez-Bonetti, P; Lupi-Herrera, E; Martinez-Guerra, M L; Barrios, R; Seoane, M; Sandoval, J

    1983-05-01

    The mechanical properties of the lung were studied in ten nonsmokers with idiopathic pulmonary artery hypertension (IPAH) (mean pulmonary artery pressure 65.7 +/- 30 mm Hg). In the routine lung test, residual volume was found to be abnormal (greater than 120 percent of the predicted) in seven patients, and measured airway resistance was normal in eight out of the ten patients. A decreased FEF 75-85 percent, abnormal values for the helium-air flow ratios and increased closing capacities were documented in eight of ten patients in whom lung elastic recoil was normal (six of ten) or increased (four of ten). These features suggest peripheral airways obstruction (PAO) which was also supported by histopathologic findings in three cases (one biopsy and two necropsies). The observed changes in lung compliance could be related to the behavior of the coupling of the air-space and vascular compartments. The etiology of PAO in IPAH patients is not known, but our results indicate that both the peripheral airways and the pulmonary circulation are affected. The knowledge of PAO in IPAH patients could help to better understand the observed V/Q inequality in this entity. PMID:6839814

  2. Transient motion of mucus plugs in respiratory airways

    NASA Astrophysics Data System (ADS)

    Zamankhan, Parsa; Hu, Yingying; Helenbrook, Brian; Takayama, Shuichi; Grotberg, James B.

    2011-11-01

    Airway closure occurs in lung diseases such as asthma, cystic fibrosis, or emphysema which have an excess of mucus that forms plugs. The reopening process involves displacement of mucus plugs in the airways by the airflow of respiration. Mucus is a non-Newtonian fluid with a yield stress; therefore its behavior can be approximated by a Bingham fluid constitutive equation. In this work the reopening process is approximated by simulation of a transient Bingham fluid plug in a 2D channel. The governing equations are solved by an Arbitrary Lagrangian Eulerian (ALE) finite element method through an in-house code. The constitutive equation for the Bingham fluid is implemented through a regularization method. The effects of the yield stress on the flow features and wall stresses are discussed with applications to potential injuries to the airway epithelial cells which form the wall. The minimum driving pressure for the initiation of the motion is computed and its value is related to the mucus properties and the plug shape. Supported by HL84370 and HL85156.

  3. Airway blood flow response to dry air hyperventilation in sheep

    SciTech Connect

    Parsons, G.H.; Baile, E.M.; Pare, P.D.

    1986-03-01

    Airway blood flow (Qaw) may be important in conditioning inspired air. To determine the effect of eucapneic dry air hyperventilation (hv) on Qaw in sheep the authors studied 7 anesthetized open-chest sheep after 25 min. of warm dry air hv. During each period of hv the authors have recorded vascular pressures, cardiac output (CO), and tracheal mucosal and inspired air temperature. Using a modification of the reference flow technique radiolabelled microspheres were injected into the left atrium to make separate measurements after humid air and dry air hv. In 4 animals a snare around the left main pulmonary artery was used following microsphere injection to prevent recirculation (entry into L lung of microspheres from the pulmonary artery). Qaw to the trachea and L lung as measured and Qaw for the R lung was estimated. After the final injection the sheep were killed and bronchi (Br) and lungs removed. Qaw (trachea plus L lung plus R lung) in 4 sheep increased from a mean of 30.8 to 67.0 ml/min. Airway mucosal temp. decreased from 39/sup 0/ to 33/sup 0/C. The authors conclude that dry air hv cools airway mucosa and increases Qaw in sheep.

  4. Surgical versus nonsurgical interventions to relieve upper airway obstruction in children with Pierre Robin sequence

    PubMed Central

    Kam, Karen; McKay, Meghan; MacLean, Joanna; Witmans, Manisha B; Spier, Sheldon; Mitchell, Ian

    2015-01-01

    BACKGROUND: Newborns with Pierre Robin sequence (PRS) often experience chronic intermittent hypoxemia/hypoventilation associated with airway obstruction. The heterogeneity of the severity of upper airway obstruction makes management a challenge; the optimal intervention in individual cases is not clear. OBJECTIVE: To investigate the prevalence of surgical/nonsurgical interventions for PRS at two children’s hospitals. Patient characteristics and outcomes were examined. METHODS: The present retrospective chart review identified 139 patients with PRS born between 2000 and 2010. Demographic information, mode of airway management, associated anomalies and syndromes, polysomnography results, length of intensive care unit and hospital stay, complications and deaths were extracted. RESULTS: Interventions included prone positioning (alone [61%]), tongue-lip adhesion (45%), nasopharyngeal intubation (28%), continuous positive airway pressure (20%), tracheostomy (19%) and mandibular distraction osteogenesis (5%). Tracheostomies were more prevalent in syndromic patients (P=0.03). Patients who underwent tracheostomy had a lower birth weight (P=0.03) compared with newborns with other interventions. Patients who underwent surgical interventions had longer intensive care unit stays (P<0.001). No intervention was associated with a statistically significant likelihood of requiring a subsequent intervention. Thirty percent of patients underwent polysomnography, with a higher proportion of these using continuous positive airway pressure (n=15) (P<0.01). CONCLUSIONS: In the present descriptive study, patients with syndromic PRS or low birth weight underwent early intervention, which included a tracheostomy. Objective measures of airway obstruction were underutilized. Decision making regarding evaluation and management of upper airway obstruction in this population remains clinician and resource dependent. Reporting data obtained from a large cohort of PRS patients is important to

  5. A randomised crossover trial comparing a single-use polyvinyl chloride laryngeal mask airway with a single-use silicone laryngeal mask airway.

    PubMed

    Bell, S F; Morris, N G; Rao, A; Wilkes, A R; Goodwin, N

    2012-12-01

    We compared insertion rates of single-use polyvinyl chloride laryngeal mask airways (LMAs) vs single-use silicone LMAs in 72 anaesthetised patients. Both airways were produced by Flexicare Medical. Laryngeal mask airway insertion was successful on the first attempt in 68/72 (94%) polyvinyl chloride LMAs vs 64/72 (89%) silicone LMAs (p = 0.39). Overall insertion rates were 72/72 (100%) for the polyvinyl chloride LMAs and 71/72 (99%) for the silicone LMAs (p = 1.0). Mean (SD) insertion times were similar for polyvinyl chloride and silicone LMAs: 24.3 (5.1)s vs 24.8 (7.8)s (p = 0.64). Laryngeal mask airway position, as assessed using a fibrescope, was not different (p = 0.077). The median (IQR [range]) leak pressure was 16 (12-20 [6-30]) cmH(2) O for the polyvinyl LMA and 18 (13-22 [6-30]) cmH(2) O or the silicone LMA (p = 0.037). In conclusion, we did not find any important differences between polyvinyl chloride and silicone laryngeal mask airways.

  6. SUBCHRONIC ENDOTOXIN INHALATION CAUSES PERSISTENT AIRWAY DISEASE

    EPA Science Inventory

    ABSTRACT

    The endotoxin component of organic dusts causes acute reversible airflow obstruction and airway inflammation. To test the hypothesis that endotoxin alone causes airway remodeling, we have compared the response of two inbred mouse strains to subchronic endotoxin ...

  7. Airway and Extracellular Matrix Mechanics in COPD.

    PubMed

    Bidan, Cécile M; Veldsink, Annemiek C; Meurs, Herman; Gosens, Reinoud

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is one of the most common lung diseases worldwide, and is characterized by airflow obstruction that is not fully reversible with treatment. Even though airflow obstruction is caused by airway smooth muscle contraction, the extent of airway narrowing depends on a range of other structural and functional determinants that impact on active and passive tissue mechanics. Cells and extracellular matrix in the airway and parenchymal compartments respond both passively and actively to the mechanical stimulation induced by smooth muscle contraction. In this review, we summarize the factors that regulate airway narrowing and provide insight into the relative contributions of different constituents of the extracellular matrix and their biomechanical impact on airway obstruction. We then review the changes in extracellular matrix composition in the airway and parenchymal compartments at different stages of COPD, and finally discuss how these changes impact airway narrowing and the development of airway hyperresponsiveness. Finally, we position these data in the context of therapeutic research focused on defective tissue repair. As a conclusion, we propose that future works should primarily target mild or early COPD, prior to the widespread structural changes in the alveolar compartment that are more characteristic of severe COPD.

  8. Athletic Trainers' Knowledge Regarding Airway Adjuncts

    ERIC Educational Resources Information Center

    Edler, Jessica R.; Eberman, Lindsey E.; Kahanov, Leamor; Roman, Christopher; Mata, Heather Lynne

    2015-01-01

    Context: Research suggests that knowledge gaps regarding the appropriate use of airway adjuncts exist among various health care practitioners, and that knowledge is especially limited within athletic training. Objective: To determine the relationship between perceived knowledge (PK) and actual knowledge (AK) of airway adjunct use and the…

  9. 21 CFR 868.5110 - Oropharyngeal airway.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Oropharyngeal airway. 868.5110 Section 868.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5110 Oropharyngeal airway....

  10. 21 CFR 868.5100 - Nasopharyngeal airway.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nasopharyngeal airway. 868.5100 Section 868.5100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5100 Nasopharyngeal airway....

  11. 21 CFR 868.5100 - Nasopharyngeal airway.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nasopharyngeal airway. 868.5100 Section 868.5100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5100 Nasopharyngeal airway....

  12. 21 CFR 868.5110 - Oropharyngeal airway.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Oropharyngeal airway. 868.5110 Section 868.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5110 Oropharyngeal airway....

  13. 21 CFR 868.5110 - Oropharyngeal airway.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oropharyngeal airway. 868.5110 Section 868.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5110 Oropharyngeal airway....

  14. 21 CFR 868.5110 - Oropharyngeal airway.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Oropharyngeal airway. 868.5110 Section 868.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5110 Oropharyngeal airway....

  15. 21 CFR 868.5100 - Nasopharyngeal airway.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nasopharyngeal airway. 868.5100 Section 868.5100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5100 Nasopharyngeal airway....

  16. 21 CFR 868.5100 - Nasopharyngeal airway.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nasopharyngeal airway. 868.5100 Section 868.5100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5100 Nasopharyngeal airway....

  17. 21 CFR 868.5110 - Oropharyngeal airway.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Oropharyngeal airway. 868.5110 Section 868.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5110 Oropharyngeal airway....

  18. 21 CFR 868.5100 - Nasopharyngeal airway.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nasopharyngeal airway. 868.5100 Section 868.5100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5100 Nasopharyngeal airway....

  19. Airway and Extracellular Matrix Mechanics in COPD

    PubMed Central

    Bidan, Cécile M.; Veldsink, Annemiek C.; Meurs, Herman; Gosens, Reinoud

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is one of the most common lung diseases worldwide, and is characterized by airflow obstruction that is not fully reversible with treatment. Even though airflow obstruction is caused by airway smooth muscle contraction, the extent of airway narrowing depends on a range of other structural and functional determinants that impact on active and passive tissue mechanics. Cells and extracellular matrix in the airway and parenchymal compartments respond both passively and actively to the mechanical stimulation induced by smooth muscle contraction. In this review, we summarize the factors that regulate airway narrowing and provide insight into the relative contributions of different constituents of the extracellular matrix and their biomechanical impact on airway obstruction. We then review the changes in extracellular matrix composition in the airway and parenchymal compartments at different stages of COPD, and finally discuss how these changes impact airway narrowing and the development of airway hyperresponsiveness. Finally, we position these data in the context of therapeutic research focused on defective tissue repair. As a conclusion, we propose that future works should primarily target mild or early COPD, prior to the widespread structural changes in the alveolar compartment that are more characteristic of severe COPD. PMID:26696894

  20. Difficult Airway Response Team: A Novel Quality Improvement Program for Managing Hospital-Wide Airway Emergencies

    PubMed Central

    Mark, Lynette J.; Herzer, Kurt R.; Cover, Renee; Pandian, Vinciya; Bhatti, Nasir I.; Berkow, Lauren C.; Haut, Elliott R.; Hillel, Alexander T.; Miller, Christina R.; Feller-Kopman, David J.; Schiavi, Adam J.; Xie, Yanjun J.; Lim, Christine; Holzmueller, Christine; Ahmad, Mueen; Thomas, Pradeep; Flint, Paul W.; Mirski, Marek A.

    2015-01-01

    Background Difficult airway cases can quickly become emergencies, increasing the risk of life-threatening complications or death. Emergency airway management outside the operating room is particularly challenging. Methods We developed a quality improvement program—the Difficult Airway Response Team (DART)—to improve emergency airway management outside the operating room. DART was implemented by a team of anesthesiologists, otolaryngologists, trauma surgeons, emergency medicine physicians, and risk managers in 2005 at The Johns Hopkins Hospital in Baltimore, Maryland. The DART program had three core components: operations, safety, and education. The operations component focused on developing a multidisciplinary difficult airway response team, standardizing the emergency response process, and deploying difficult airway equipment carts throughout the hospital. The safety component focused on real-time monitoring of DART activations and learning from past DART events to continuously improve system-level performance. This objective entailed monitoring the paging system, reporting difficult airway events and DART activations to a web-based registry, and using in situ simulations to identify and mitigate defects in the emergency airway management process. The educational component included development of a multispecialty difficult airway curriculum encompassing case-based lectures, simulation, and team building/communication to ensure consistency of care. Educational materials were also developed for non-DART staff and patients to inform them about the needs of patients with difficult airways and ensure continuity of care with other providers after discharge. Results Between July 2008 and June 2013, DART managed 360 adult difficult airway events comprising 8% of all code activations. Predisposing patient factors included body mass index > 40, history of head and neck tumor, prior difficult intubation, cervical spine injury, airway edema, airway bleeding, and previous

  1. Airway fires during surgery: Management and prevention

    PubMed Central

    Akhtar, Navaid; Ansar, Farrukh; Baig, Mirza Shahzad; Abbas, Akbar

    2016-01-01

    Airway fires pose a serious risk to surgical patients. Fires during surgery have been reported for many years with flammable anesthetic agents being the main culprits in the past. Association of airway fires with laser surgery is well-recognized, but there are reports of endotracheal tube fires ignited by electrocautery during pharyngeal surgery or tracheostomy or both. This uncommon complication has potentially grave consequences. While airway fires are relatively uncommon occurrences, they are very serious and can often be fatal. Success in preventing such events requires a thorough understanding of the components leading to a fire (fuel, oxidizer, and ignition source), as well as good communication between all members present to appropriately manage the fire and ensure patient safety. We present a case of fire in the airway during routine adenotonsillectomy. We will review the causes, preventive measures, and brief management for airway fires. PMID:27006554

  2. Airway fires during surgery: Management and prevention.

    PubMed

    Akhtar, Navaid; Ansar, Farrukh; Baig, Mirza Shahzad; Abbas, Akbar

    2016-01-01

    Airway fires pose a serious risk to surgical patients. Fires during surgery have been reported for many years with flammable anesthetic agents being the main culprits in the past. Association of airway fires with laser surgery is well-recognized, but there are reports of endotracheal tube fires ignited by electrocautery during pharyngeal surgery or tracheostomy or both. This uncommon complication has potentially grave consequences. While airway fires are relatively uncommon occurrences, they are very serious and can often be fatal. Success in preventing such events requires a thorough understanding of the components leading to a fire (fuel, oxidizer, and ignition source), as well as good communication between all members present to appropriately manage the fire and ensure patient safety. We present a case of fire in the airway during routine adenotonsillectomy. We will review the causes, preventive measures, and brief management for airway fires. PMID:27006554

  3. Awake Craniotomy: A New Airway Approach.

    PubMed

    Sivasankar, Chitra; Schlichter, Rolf A; Baranov, Dimitry; Kofke, W Andrew

    2016-02-01

    Awake craniotomies have been performed regularly at the University of Pennsylvania since 2004. Varying approaches to airway management are described for this procedure, including intubation with an endotracheal tube and use of a laryngeal mask airway, simple facemask, or nasal cannula. In this case series, we describe the successful use (i.e., no need for endotracheal intubation related to inadequate gas exchange) of bilateral nasopharyngeal airways in 90 patients undergoing awake craniotomies. The use of nasopharyngeal airways can ease the transition between the asleep and awake phases of the craniotomy without the need to stimulate the airway. Our purpose was to describe our experience and report adverse events related to this technique. PMID:26579845

  4. Anaesthetic management of acute airway obstruction

    PubMed Central

    Wong, Patrick; Wong, Jolin; Mok, May Un Sam

    2016-01-01

    The acutely obstructed airway is a medical emergency that can potentially result in serious morbidity and mortality. Apart from the latest advancements in anaesthetic techniques, equipment and drugs, publications relevant to our topic, including the United Kingdom’s 4th National Audit Project on major airway complications in 2011 and the updated American Society of Anesthesiologists’ difficult airway algorithm of 2013, have recently been published. The former contained many reports of adverse events associated with the management of acute airway obstruction. By analysing the data and concepts from these two publications, this review article provides an update on management techniques for the acutely obstructed airway. We discuss the principles and factors relevant to the decision-making process in formulating a logical management plan. PMID:26996162

  5. Vocal Function and Upper Airway Thermoregulation in Five Different Environmental Conditions

    ERIC Educational Resources Information Center

    Sandage, Mary J.; Connor, Nadine P.; Pascoe, David D.

    2014-01-01

    Purpose: Phonation threshold pressure and perceived phonatory effort were hypothesized to increase and upper airway temperature to decrease following exposure to cold and/or dry air. Greater changes were expected with mouth versus nose breathing. Method: In a within-participant repeated measures design, 15 consented participants (7 men, 8 women)…

  6. Investigating the geometry of pig airways using computed tomography

    NASA Astrophysics Data System (ADS)

    Mansy, Hansen A.; Azad, Md Khurshidul; McMurray, Brandon; Henry, Brian; Royston, Thomas J.; Sandler, Richard H.

    2015-03-01

    Numerical modeling of sound propagation in the airways requires accurate knowledge of the airway geometry. These models are often validated using human and animal experiments. While many studies documented the geometric details of the human airways, information about the geometry of pig airways is scarcer. In addition, the morphology of animal airways can be significantly different from that of humans. The objective of this study is to measure the airway diameter, length and bifurcation angles in domestic pigs using computed tomography. After imaging the lungs of 3 pigs, segmentation software tools were used to extract the geometry of the airway lumen. The airway dimensions were then measured from the resulting 3 D models for the first 10 airway generations. Results showed that the size and morphology of the airways of different animals were similar. The measured airway dimensions were compared with those of the human airways. While the trachea diameter was found to be comparable to the adult human, the diameter, length and branching angles of other airways were noticeably different from that of humans. For example, pigs consistently had an early airway branching from the trachea that feeds the superior (top) right lung lobe proximal to the carina. This branch is absent in the human airways. These results suggested that the human geometry may not be a good approximation of the pig airways and may contribute to increasing the errors when the human airway geometric values are used in computational models of the pig chest.

  7. Nucleotide release by airway epithelia.

    PubMed

    Lazarowski, Eduardo R; Sesma, Juliana I; Seminario, Lucia; Esther, Charles R; Kreda, Silvia M

    2011-01-01

    The purinergic events regulating the airways' innate defenses are initiated by the release of purines from the epithelium, which occurs constitutively and is enhanced by chemical or mechanical stimulation. While the external triggers have been reviewed exhaustively, this chapter focuses on current knowledge of the receptors and signaling cascades mediating nucleotide release. The list of secreted purines now includes ATP, ADP, AMP and nucleotide sugars, and involves at least three distinct mechanisms reflecting the complexity of airway epithelia. First, the constitutive mechanism involves ATP translocation to the ER/Golgi complex as energy source for protein folding, and fusion of Golgi-derived vesicles with the plasma membrane. Second, goblet cells package ATP with mucins into granules, which are discharged in response to P2Y(2)R activation and Ca(2+)-dependent signaling pathways. Finally, non-mucous cells support a regulated mechanism of ATP release involving protease activated receptor (PAR)-elicited G(12/13) activation, leading to the RhoGEF-mediated exchange of GDP for GTP on RhoA, and cytoskeleton rearrangement. Together, these pathways provide fine tuning of epithelial responses regulated by purinergic signaling events. PMID:21560042

  8. Airway Clearance Devices for Cystic Fibrosis

    PubMed Central

    2009-01-01

    Executive Summary Objective The purpose of this evidence-based analysis is to examine the safety and efficacy of airway clearance devices (ACDs) for cystic fibrosis and attempt to differentiate between devices, where possible, on grounds of clinical efficacy, quality of life, safety and/or patient preference. Background Cystic fibrosis (CF) is a common, inherited, life-limiting disease that affects multiple systems of the human body. Respiratory dysfunction is the primary complication and leading cause of death due to CF. CF causes abnormal mucus secretion in the airways, leading to airway obstruction and mucus plugging, which in turn can lead to bacterial infection and further mucous production. Over time, this almost cyclical process contributes to severe airway damage and loss of respiratory function. Removal of airway secretions, termed airway clearance, is thus an integral component of the management of CF. A variety of methods are available for airway clearance, some requiring mechanical devices, others physical manipulation of the body (e.g. physiotherapy). Conventional chest physiotherapy (CCPT), through the assistance of a caregiver, is the current standard of care for achieving airway clearance, particularly in young patients up to the ages of six or seven. CF patients are, however, living much longer now than in decades past. The median age of survival in Canada has risen to 37.0 years for the period of 1998-2002 (5-year window), up from 22.8 years for the 5-year window ending in 1977. The prevalence has also risen accordingly, last recorded as 3,453 in Canada in 2002, up from 1,630 in 1977. With individuals living longer, there is a greater need for independent methods of airway clearance. Airway Clearance Devices There are at least three classes of airway clearance devices: positive expiratory pressure devices (PEP), airway oscillating devices (AOD; either handheld or stationary) and high frequency chest compression (HFCC)/mechanical percussion (MP

  9. Upper airway muscles awake and asleep.

    PubMed

    Sériès, Frédéric

    2002-06-01

    Upper airway (UA) structures are involved in different respiratory and non-respiratory tasks. The coordination of agonist and antagonist UA dilators is responsible for their mechanical function and their ability to maintain UA patency throughout the respiratory cycle. The activity of these muscles is linked with central respiratory activity but also depends on UA pressure changes and is greatly influenced by sleep. UA muscles are involved in determining UA resistance and stability (i.e. closing pressure), and the effect of sleep on these variables may be accounted for by its effect on tonic and phasic skeletal muscle activities. The mechanical effects of UA dilator contraction also depend on their physiological properties (capacity to generate tension in vitro, activity of the anaerobic enzymatic pathway, histo-chemical characteristics that may differ between subjects who may or may not have sleep-related obstructive breathing disorders). These characteristics may represent an adaptive process to an increased resistive loading of these muscles. The apparent discrepancy between the occurrence of UA closure and an increased capacity to generate tension in sleep apnea patients may be due to a reduction in the effectiveness of UA muscle contraction in these patients; such an increase in tissue stiffness could be accounted for by peri-muscular tissue characteristics. Therefore, understanding of UA muscle physiological characteristics should take into account its capacity for force production and its mechanical coupling with other UA tissues. Important research goals for the future will be to integrate these issues with other physiological features of the disease, such as UA size and dimension, histological characteristics of UA tissues and the effect of sleep on muscle function. Such integration will better inform understanding of the role of pharyngeal UA muscles in the pathophysiology of the sleep apnea/hypopnea syndrome. PMID:12531123

  10. Educating the Educator: Teaching Airway Adjunct Techniques in Athletic Training

    ERIC Educational Resources Information Center

    Berry, David C.; Seitz, S. Robert

    2011-01-01

    The 5th edition of the "Athletic Training Education Competencies" ("Competencies") now requires athletic training educators (ATEs) to introduce into the curriculum various types of airway adjuncts including: (1) oropharyngeal airways (OPA), (2) nasopharyngeal airways (NPA), (3) supraglottic airways (SGA), and (4) suction. The addition of these…

  11. Small particles disrupt postnatal airway development

    PubMed Central

    Lee, DongYoub; Wallis, Chris; Schelegle, Edward S.; Van Winkle, Laura S.; Plopper, Charles G.; Fanucchi, Michelle V.; Kumfer, Ben; Kennedy, Ian M.; Chan, Jackie K. W.

    2010-01-01

    Increasing numbers of epidemiologic studies associate air pollution exposure in children with decreased lung function development. The objective of this study was to examine the effects of exposure to combustion-generated fine [230 and 212 nm number mean aerodynamic particle diameter (NMAD)] to ultrafine (73 nm NMAD) particles differing in elemental (EC) and organic (OC) carbon content on postnatal airway development in rats. Neonatal Sprague-Dawley rats were exposed from postnatal day 7 through 25, and lung function and airway architecture were evaluated 81 days of age. In a separate group of rats, cell proliferation was examined after a single particle exposure at 7 days of age. Early life exposure to 73 nm high OC/EC particles altered distal airway architecture and resulted in subtle changes in lung mechanics. Early life exposure to 212 nm high OC/EC particles did not alter lung architecture but did alter lung mechanics in a manner suggestive of central airway changes. In contrast, early life exposure to 230 nm low OC/EC particles did not alter lung architecture or mechanics. A single 6-h exposure to 73 nm high OC/EC particle decreased airway cell proliferation, whereas 212 nm high OC/EC particles increased it and 230 nm low OC/EC particles did not. The early life exposure to ultrafine, high OC/EC particles results in persistent alterations in distal airway architecture that is characterized by an initial decrease in airway cell proliferation. PMID:20634362

  12. Comparison of analysis methods for airway quantification

    NASA Astrophysics Data System (ADS)

    Odry, Benjamin L.; Kiraly, Atilla P.; Novak, Carol L.; Naidich, David P.

    2012-03-01

    Diseased airways have been known for several years as a possible contributing factor to airflow limitation in Chronic Obstructive Pulmonary Diseases (COPD). Quantification of disease severity through the evaluation of airway dimensions - wall thickness and lumen diameter - has gained increased attention, thanks to the availability of multi-slice computed tomography (CT). Novel approaches have focused on automated methods of measurement as a faster and more objective means that the visual assessment routinely employed in the clinic. Since the Full-Width Half-Maximum (FWHM) method of airway measurement was introduced two decades ago [1], several new techniques for quantifying airways have been detailed in the literature, but no approach has truly become a standard for such analysis. Our own research group has presented two alternative approaches for determining airway dimensions, one involving a minimum path and the other active contours [2, 3]. With an increasing number of techniques dedicated to the same goal, we decided to take a step back and analyze the differences of these methods. We consequently put to the test our two methods of analysis and the FWHM approach. We first measured a set of 5 airways from a phantom of known dimensions. Then we compared measurements from the three methods to those of two independent readers, performed on 35 airways in 5 patients. We elaborate on the differences of each approach and suggest conclusions on which could be defined as the best one.

  13. Implantation of a defibrillator in a patient with an upper airway stimulation device.

    PubMed

    Ong, Adrian A; O'Brien, Terrence X; Nguyen, Shaun A; Gillespie, M Boyd

    2016-02-01

    The patient is a 62-year-old man with continuous positive airway pressure-intolerant obstructive sleep apnea who was enrolled in a study for a hypoglossal nerve upper airway stimulation device (UAS). Nearly 2.5 years later, he was admitted to the hospital for unstable angina. Diagnostic workup revealed a prior myocardial infarction, an ejection fraction of 30% on maximal medical therapy, and episodes of nonsustained ventricular tachycardia. During hospitalization, the patient received an implantable cardioverter defibrillator (ICD). This is the first reported case of simultaneous use of a UAS and an ICD, and we report no untoward device interference between the two implantable devices.

  14. The status of cephalometry in the prediction of non-CPAP treatment outcome in obstructive sleep apnea patients.

    PubMed

    Denolf, Petra L; Vanderveken, Olivier M; Marklund, Marie E; Braem, Marc J

    2016-06-01

    Obstructive sleep apnea syndrome (OSAS) is the most common sleep disordered breathing disorder (SDB) in adults and is characterized by a recurrent partial or complete collapse of the upper airway during sleep. This can be caused by many factors, sometimes interacting, such as skeletal malformations, soft tissue crowding, respiratory instability and the various effects of aging, obesity and gender that dictate craniofacial and upper airway anatomy. Research has demonstrated that the majority of patients exhibit at least one anatomical component such as retrognathia or a narrow posterior airway space that predisposes to the development of OSAS. Within the predisposing elements for OSAS many seem to point to anatomical characteristics. A standardized and relatively simple radiologic technique to evaluate anatomical craniofacial relationships is cephalometry. This has been used already for a long time in orthodontics, but is now gradually being introduced in OSAS treatment to envisage optimal treatment selection as well as to predict treatment outcomes. The purpose of the present review is to evaluate the contribution of cephalometry in the prediction of outcomes from OSAS treatments that depend on the upper airway morphology in their mechanisms of action such as oral appliances that advance the mandible as well as various surgical methods. In addition, an overview of imaging modalities and methods that currently are being used in cephalometric analysis in OSAS patients is provided. The findings indicate that isolated cephalometric parameters cannot be used to reliably predict treatment outcomes from mandibular advancement devices and surgical methods for OSAS. Extreme or outlying values of cephalometric parameters may rather be used as contra-indicators or 'red flags' instead of predictors.

  15. Firefighting acutely increases airway responsiveness.

    PubMed

    Sherman, C B; Barnhart, S; Miller, M F; Segal, M R; Aitken, M; Schoene, R; Daniell, W; Rosenstock, L

    1989-07-01

    The acute effects of the products of combustion and pyrolysis on airway responsiveness among firefighters are poorly documented. To study this relationship, spirometry and methacholine challenge testing (MCT) were performed on 18 active Seattle firefighters before and 5 to 24 h after firefighting. Body plethysmography was used to measure changes in specific airway conductance (SGaw), and results of MCT were analyzed using PD35-SGaw, the cumulative dose causing a 35% decrease in SGaw. Subjects who did not react by the end of the protocol were assigned a value of 640 inhalational units, the largest cumulative dose. Fire exposure was defined as the total time (hours) spent without a self-contained breathing apparatus at the firesite and was categorized as mild (less than 1 h, n = 7), moderate (1 to 2 h, n = 5), or severe (greater than 2 h, n = 6). Mean age of the 18 firefighters was 36.7 +/- 6.7 yr (range, 25 to 51), with a mean of 9.1 +/- 7.9 active years in the trade (range, zero to 22). None was known to be asthmatic. After firefighting, FEV1 % predicted (%pred) and FEF25-75 %pred significantly decreased by means of 3.4 +/- 1.1% and 5.6 +/- 2.6%, respectively. The mean decline in PD35-SGaw after firefighting was 184.5 +/- 53.2 units (p = 0.003). This observed decline in PD35-SGaw could not be explained by decrements in prechallenge SGaw, FEV1, or FVC.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Non-invasive respiratory support for infants in low- and middle-income countries.

    PubMed

    Jensen, Erik A; Chaudhary, Aasma; Bhutta, Zulfiqar A; Kirpalani, Haresh

    2016-06-01

    The overwhelming majority of neonatal deaths worldwide occur in low- and middle-income countries. Most of these deaths are attributable to respiratory illnesses and complications of preterm birth. The available data suggest that non-invasive continuous positive airway pressure (CPAP) is a safe and cost-effective therapy to reduce neonatal morbidity and mortality in these settings. Bubble CPAP compared to mechanical ventilator-generated CPAP reduces the need for subsequent invasive ventilation in newborn infants. There are limited data on the safety and efficacy of high-flow nasal cannulae in low- and middle-income countries, requiring further study prior to widespread implementation. PMID:26915655

  17. On locating the obstruction in the upper airway via numerical simulation

    PubMed Central

    Wang, Yong; Elghobashi, S.

    2014-01-01

    The fluid dynamical properties of the air flow in the upper airway (UA) are not fully understood at present due to the three-dimensional (3D) patient-specific complex geometry of the airway, flow transition from laminar to turbulent and flow-structure interaction during the breathing cycle. It is quite difficult at present to experimentally measure the instantaneous velocity and pressure at specific points in the human airway. On the other hand, direct numerical simulation (DNS) can predict all the flow properties and resolve all its relevant length- and time-scales. We developed a DNS solver with the state-of-the-art lattice Boltzmann method (LBM), and used it to investigate the flow in two patient-specific UAs reconstructed from CT scan data. Inspiration and expiration flows through these two airways are studied. The time-averaged first spatial derivative of pressure (pressure gradient), ∂p/∂z, is used to locate the region of the UA obstruction. But the time-averaged second spatial derivative, ∂2p/∂z2, is used to pinpoint the exact location of the obstruction. The present results show that the DNS-LBM solver can be used to obtain accurate flow details in the UA and is a powerful tool to locate its obstruction. PMID:24389271

  18. Vocal Function and Upper Airway Thermoregulation in Five Different Environmental Conditions

    PubMed Central

    Sandage, Mary J.; Connor, Nadine P.; Pascoe, David D.

    2013-01-01

    Purpose Phonation threshold pressure and perceived phonatory effort were hypothesized to increase and upper airway temperature decrease following exposure to cold and/or dry air. Greater changes were expected with mouth versus nose breathing. Method Using a within-participant repeated measures design, 15 consented participants (7 men, 8 women) completed 20-minute du