Science.gov

Sample records for ak multidetector computed

  1. Bladder trauma: multidetector computed tomography cystography.

    PubMed

    Ishak, Charbel; Kanth, Nalini

    2011-08-01

    Multidetector computed tomography (MDCT) cystography is rapidly becoming the most recommended study for evaluation of the bladder for suspected trauma. This article reviews the bladder trauma with emphasis on the application of MDCT cystography to traumatic bladder injuries using a pictorial essay based on images collected in our level I trauma center.

  2. Multidetector computed tomography angiography of the abdomen.

    PubMed

    Güven, Koray; Acunaş, Bülent

    2004-10-01

    Multidetector computed tomography (MDCT) angiography has provided excellent opportunities for advancement of computed tomography (CT) technology and clinical applications. It has a wide range of applications in the abdomen including vascular pathologies either occlusive or aneurysmal; enables the radiologist to produce vascular mapping that clearly show tumor invasion of vasculature and the relationship of vessels to mass lesions. MDCTA can be used in preoperative planning for hepatic resection, preoperative evaluation and planning for liver transplantation. MDCTA can also provide extremely valuable information in the evaluation of ischemic bowel disease, active Crohn disease, the extent and location of collateral vessels in cirrhosis.

  3. [Valvular heart disease: multidetector computed tomography evaluation].

    PubMed

    Franco, A; Fernández-Pérez, G C; Tomás-Mallebrera, M; Badillo-Portugal, S; Orejas, M

    2014-01-01

    Heart valve disease is a clinical problem that has been studied with classical imaging techniques like echocardiography and MRI. Technological advances in CT make it possible to obtain static and dynamic images that enable not only a morphological but also a functional analysis in many cases. Although it is currently indicated only in patients with inconclusive findings at echocardiography and MRI or those in whom these techniques are contraindicated, multidetector CT makes it possible to diagnose stenosis or regurgitation through planimetry, to evaluate and quantify valvular calcium, and to show the functional repercussions of these phenomena on the rest of the structures of the heart. Given that multidetector CT is being increasingly used in the diagnosis of ischemic heart disease, we think it is interesting for radiologists to know its potential for the study of valvular disease.

  4. [The different manifestations of pulmonary aspergillosis: multidetector computed tomography findings].

    PubMed

    Koren Fernández, L; Alonso Charterina, S; Alcalá-Galiano Rubio, A; Sánchez Nistal, M A

    2014-01-01

    Pulmonary aspergillosis is a fungal infection usually caused by inhaling Aspergillus fumigatus spores. However, when we talk about aspergillosis, we normally refer to the spectrum of clinical and radiological findings that depend directly on the patient's immune status, on the prior existence of lung disease, and on the virulence of the infective organism. There are four types of pulmonary aspergillosis (aspergilloma, allergic bronchopulmonary aspergillosis, chronic necrotizing pulmonary aspergillosis, and invasive aspergillosis), and each type has its own distinct radiologic findings. We review the signs of pulmonary aspergillosis on multidetector computed tomography and we correlate them with patients' symptoms and immune responses. Likewise, we discuss the differential diagnoses.

  5. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    PubMed Central

    Matos, António P.; Mascarenhas, Vasco; Herédia, Vasco

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall. PMID:25295188

  6. Multidetector computer tomography: evaluation of blunt chest trauma in adults.

    PubMed

    Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  7. Multidetector Computed Tomography for Congenital Anomalies of the Aortic Arch: Vascular Rings.

    PubMed

    García-Guereta, Luis; García-Cerro, Estefanía; Bret-Zurita, Montserrat

    2016-07-01

    The development of multidetector computed tomography has triggered a revolution in the study of the aorta and other large vessels and has replaced angiography in the diagnosis of congenital anomalies of the aortic arch, particularly vascular rings. The major advantage of multidetector computed tomography is that it permits clear 3-dimensional assessment of not only vascular structures, but also airway and esophageal compression. The current update aims to summarize the embryonic development of the aortic arch and the developmental anomalies leading to vascular ring formation and to discuss the current diagnostic and therapeutic role of multidetector computed tomography in this field.

  8. Multidetector computed tomography findings in deaths with severe burns.

    PubMed

    Levy, Angela D; Harcke, Howard T; Getz, John M; Mallak, Craig T

    2009-06-01

    This study compared autopsy with postmortem multidetector computed tomography (MDCT) findings in charred remains. Seventeen consecutive male subjects (mean age, 29.4 years) who perished in a fire-related event resulting in charred remains underwent total body MDCT immediately prior to routine autopsy that included serum carboxyhemoglobin measurement. MDCT showed all thermal tissue changes (skin and subcutaneous fat loss, skeletal muscle retraction, pugilistic attitude, cortical fractures, bone and organ destruction, thermal epidural hematoma, and thermal amputation) and established all fracture patterns that were lethal, but autopsy added the fire as a contributory cause of death when there was carboxyhemoglobin elevation. MDCT had limited value in determination of lethal vascular and visceral injuries. MDCT is an effective complement to autopsy in the setting of charred remains and may serve to augment a limited autopsy. This may be particularly useful in mass casualty scenarios.

  9. Common carotid artery pseudoaneurysm after neck dissection: colour Doppler ultrasound and multidetector computed tomography findings.

    PubMed

    Flor, N; Sardanelli, F; Ghilardi, G; Tentori, A; Franceschelli, G; Felisati, G; Cornalba, G P

    2007-05-01

    Common carotid artery pseudoaneurysm is a rare disease, which has been previously unreported in association with neck dissection. We describe the Doppler ultrasound and multidetector computed tomography (CT) findings of a case of carotid pseudoaneurysm, one month after pharyngolaryngectomy with bilateral neck dissection. Multidetector CT confirmed the diagnosis made on the basis of Doppler ultrasound; the high image quality of axial and three-dimensional reconstructions avoided the need for pre-operative conventional angiography. In the presence of a pulsatile cervical mass after neck surgery, pseudoaneurysm of the carotid artery should be included in the differential diagnosis, and multidetector CT can be the sole pre-operative diagnostic imaging modality.

  10. 64-MULTIDETECTOR COMPUTED TOMOGRAPHIC ANGIOGRAPHY OF THE CANINE CORONARY ARTERIES

    PubMed Central

    Drees, Randi; Frydrychowicz, Alex; Reeder, Scott B.; Pinkerton, Marie E.; Johnson, Rebecca

    2012-01-01

    Canine coronary artery angiography (CTA) was performed in four anesthetized healthy dogs using 64-multi-detector computed tomography. Esmolol, a β-1 adrenergic receptor antagonist, and sodium nitroprusside, an arteriolar and venous dilator, were administered to enhance visualization of the coronary arteries by reducing heart rate and creating vasodilation. The left main coronary artery with its three main branches and the right coronary artery were visualized and subdivided in 13 segments for evaluation. Optimal reconstruction interval, expressed as percentage of the R-to-R interval, was determined at 5% in 2.9%, 35% in 1%, 75% in 21.2%, 85% in 43.3%, and 95% in 31.7% of the segments. Overall image quality was good in 41.3% of the segments and excellent in 14.4%. There was blur in 98.1%, motion in 17.3%, and stair step in 6.7% of the evaluated segments, but these artifacts did not interfere with anatomic depiction of the arteries. Cross-sectional anatomy of the coronary arteries as evaluated from the coronary CTA agreed well with gross anatomic evaluation and published information. The use of esmolol did not lead to the target heart rate of 60–65 beats/min. Nitroprusside had no significant effect on visualized length or diameter of the coronary artery branches. Coronary CTA is useful for the anatomic depiction of coronary artery branches in the dog. PMID:21521398

  11. Coronary artery imaging with multidetector computed tomography: a call for an evidence-based, multidisciplinary approach.

    PubMed

    Schoenhagen, Paul; Stillman, Arthur E; Garcia, Mario J; Halliburton, Sandra S; Tuzcu, E Murat; Nissen, Steven E; Modic, Michael T; Lytle, Bruce W; Topol, Eric J; White, Richard D

    2006-05-01

    Modern multidetector computed tomography systems are capable of a comprehensive assessment of the cardiovascular system, including noninvasive assessment of coronary anatomy. Multidetector computed tomography is expected to advance the role of noninvasive imaging for coronary artery disease, but clinical experience is still limited. Clinical guidelines are necessary to standardize scanner technology and appropriate clinical applications for coronary computed tomographic angiography. Further evaluation of this evolving technology will benefit from cooperation between different medical specialties, imaging scientists, and manufacturers of multidetector computed tomography systems, supporting multidisciplinary teams focused on the diagnosis and treatment of early and advanced stages of coronary artery disease. This cooperation will provide the necessary education, training, and guidelines for physicians and technologists assuring standard of care for their patients.

  12. Evaluation of posterior clinoid process pneumatization by multidetector computed tomography.

    PubMed

    Burulday, Veysel; Akgül, Mehmet Hüseyin; Muluk, Nuray Bayar; Ozveren, Mehmet Faik; Kaya, Ahmet

    2016-10-21

    In the present study, we investigated the types and ratio of posterior clinoid process (PCP) pneumatization in paranasal sinus multidetector computed tomography (MDCT). Paranasal MDCT images of 541 subjects (227 males, 314 females), between 15 and 65 years old, were included into the study. Pneumatization of anterior clinoid process and pneumatization types (I, II, or III) were evaluated in the males and females. PCP pneumatization was detected in 20.7 % of the males and 11.5 % of the females. Right, left, and bilateral PCP pneumatizations were detected in 7.9, 5.7, and 7.0 % of the males and 2.9, 3.2, and 4.5 % of the females, respectively. PCP pneumatization of the males is significantly higher than the females. The most detected type of pneumatization was type I (61.2 %) for all groups. In right, left, and bilateral pneumatizations separately, type I pneumatization was the most detected pneumatization type with the ratio of the 70.4, 65.2, and 50.0 %, respectively. In males, type I (61.7 %), and similarly in females, type I (60.6 %) pneumatization were detected more. Type II and type III pneumatizations were detected in decreasing order in both groups. In younger subjects, pneumatization of posterior clinoid process was found as higher, and in older subjects, PCP pneumatization was found as lower. Sclerosis process related to the aging may be responsible for the lower pneumatization ratios in older subjects. Structure of the surrounding regions of PCP is important for surgical procedures related to cavernous sinus, basilar apex aneurysms, and mass lesions. Preoperative radiological examinations are useful for operative planning. Any anomalies to PCP can cause unnecessary injury to the neurovascular complex structure around the cavernous sinus or postclinoidectomy CSF fistulas. Posterior clinoidectomies should be avoided in patients with type III PCP pneumatization to prevent CSF fistulas.

  13. Advances and perspectives in lung cancer imaging using multidetector row computed tomography.

    PubMed

    Coche, Emmanuel

    2012-10-01

    The introduction of multidetector row computed tomography (CT) into clinical practice has revolutionized many aspects of the clinical work-up. Lung cancer imaging has benefited from various breakthroughs in computing technology, with advances in the field of lung cancer detection, tissue characterization, lung cancer staging and response to therapy. Our paper discusses the problems of radiation, image visualization and CT examination comparison. It also reviews the most significant advances in lung cancer imaging and highlights the emerging clinical applications that use state of the art CT technology in the field of lung cancer diagnosis and follow-up.

  14. Multidetector computed tomography of pediatric large airway diseases: state-of-the-art.

    PubMed

    Lee, Edward Y; Greenberg, S Bruce; Boiselle, Phillip M

    2011-09-01

    Advances in multidetector computed tomography (MDCT) technology have given rise to improvements in the noninvasive and comprehensive assessment of the large airways in pediatric patients. Superb two-dimensional and three-dimensional reconstruction MDCT images have revolutionized the display of large airways and enhanced the ability to diagnose large airway diseases in children. The 320-MDCT scanner, which provides combined detailed anatomic and dynamic functional information assessment of the large airways, is promising for the assessment of dynamic large airway disease such as tracheobronchomalacia. This article discusses imaging techniques and clinical applications of MDCT for assessing large airway diseases in pediatric patients.

  15. Absence of a sphenoid wing in neurofibromatosis type 1 disease: imaging with multidetector computed tomography.

    PubMed

    Onbas, Omer; Aliagaoglu, Cihangir; Calikoglu, Cagatay; Kantarci, Mecit; Atasoy, Mustafa; Alper, Fatih

    2006-01-01

    Neurofibromatosis type 1 disease is characterized by pigmented cutaneous lesions and generalized tumors of a neural crest origin and it may affect all the systems of the human body. Sphenoid dysplasia is one of the characteristics of this syndrome and it occurs in 5-10% of the cases; further, abnormalities of the sphenoid wings are often considered pathognomonic. However, complete agenesis of a sphenoid wing is very rare. We report here on an unusual case of neurofibromatosis type 1 disease with the associated absence of a sphenoid wing that was diagnosed by using multidetector computed tomography.

  16. Extraperitoneal Rupture of a Bladder Diverticulum and the Role of Multidetector Computed Tomography Cystography.

    PubMed

    Kodama, Koichi; Takase, Yasukazu; Saito, Katsuhiko

    2016-11-01

    Nontraumatic rupture of the bladder is less widely recognized than traumatic rupture, with a challenging early diagnosis due to high variability in clinical presentations. We report a case of extraperitoneal rupture of a bladder diverticulum in a patient with diabetes mellitus who presented with paralytic ileus. Despite conservative management, the patient developed sepsis requiring surgical treatment. Urinary tract infection and bladder outlet obstruction were considered to be potential mechanisms of the rupture. Multidetector computed tomography cystography should be used as the first-line modality when evaluating for a suspected bladder rupture, even in patients with nontraumatic bladder rupture.

  17. Identification of Cardiac and Aortic Injuries in Trauma with Multi-detector Computed Tomography.

    PubMed

    Shergill, Arvind K; Maraj, Tishan; Barszczyk, Mark S; Cheung, Helen; Singh, Navneet; Zavodni, Anna E

    2015-01-01

    Blunt and penetrating cardiovascular (CV) injuries are associated with a high morbidity and mortality. Rapid detection of these injuries in trauma is critical for patient survival. The advent of multi-detector computed tomography (MDCT) has led to increased detection of CV injuries during rapid comprehensive scanning of stabilized major trauma patients. MDCT has the ability to acquire images with a higher temporal and spatial resolution, as well as the capability to create multiplanar reformats. This pictorial review illustrates several common and life-threatening traumatic CV injuries from a regional trauma center.

  18. Identification of Cardiac and Aortic Injuries in Trauma with Multi-detector Computed Tomography

    PubMed Central

    Shergill, Arvind K; Maraj, Tishan; Barszczyk, Mark S; Cheung, Helen; Singh, Navneet; Zavodni, Anna E

    2015-01-01

    Blunt and penetrating cardiovascular (CV) injuries are associated with a high morbidity and mortality. Rapid detection of these injuries in trauma is critical for patient survival. The advent of multi-detector computed tomography (MDCT) has led to increased detection of CV injuries during rapid comprehensive scanning of stabilized major trauma patients. MDCT has the ability to acquire images with a higher temporal and spatial resolution, as well as the capability to create multiplanar reformats. This pictorial review illustrates several common and life-threatening traumatic CV injuries from a regional trauma center. PMID:26430541

  19. Tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography: association with N categories

    PubMed Central

    Li, Hang; Chen, Xiao-li; Li, Jun-ru; Li, Zhen-lin; Chen, Tian-wu; Pu, Hong; Yin, Long-lin; Xu, Guo-hui; Li, Zhen-wen; Reng, Jing; Zhou, Peng; Cheng, Zhu-zhong; Cao, Ying

    2016-01-01

    OBJECTIVE: To determine whether the gross tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography could predict the presence of regional lymph node metastasis and could determine N categories. MATERIALS AND METHODS: A total of 202 consecutive patients with gastric adenocarcinoma who had undergone gastrectomy 1 week after contrast-enhanced multidetector computed tomography were retrospectively identified. The gross tumor volume was evaluated on multidetector computed tomography images. Univariate and multivariate analyses were performed to determine whether the gross tumor volume could predict regional lymph node metastasis, and the Mann-Whitney U test was performed to compare the gross tumor volume among N categories. Additionally, a receiver operating characteristic analysis was performed to identify the accuracy of the gross tumor volume in differentiating N categories. RESULTS: The gross tumor volume could predict regional lymph node metastasis (p<0.0001) in the univariate analysis, and the multivariate analyses indicated that the gross tumor volume was an independent risk factor for regional lymph node metastasis (p=0.005, odds ratio=1.364). The Mann-Whitney U test showed that the gross tumor volume could distinguish N0 from the N1-N3 categories, N0-N1 from N2-N3, and N0-N2 from N3 (all p<0.0001). In the T1-T4a categories, the gross tumor volume could differentiate N0 from the N1-N3 categories (cutoff, 12.3 cm3), N0-N1 from N2-N3 (cutoff, 16.6 cm3), and N0-N2 from N3 (cutoff, 24.6 cm3). In the T4a category, the gross tumor volume could differentiate N0 from the N1-N3 categories (cutoff, 15.8 cm3), N0-N1 from N2-N3 (cutoff, 17.8 cm3), and N0-N2 from N3 (cutoff, 24 cm3). CONCLUSION: The gross tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography could predict regional lymph node metastasis and N categories. PMID:27166769

  20. Neurologic applications of whole-brain volumetric multidetector computed tomography.

    PubMed

    Snyder, Kenneth V; Mokin, Maxim; Bates, Vernice E

    2014-02-01

    The introduction of computed tomography (CT) scanning in the 1970s revolutionized the way clinicians could diagnose and treat stroke. Subsequent advances in CT technology significantly reduced radiation dose, reduced metallic artifact, and achieved speeds that enable dynamic functional studies. The recent addition of whole-brain volumetric CT perfusion technology has given clinicians a powerful tool to assess parenchymal perfusion parameters as well as visualize dynamic changes in blood vessel flow throughout the brain during a single cardiac cycle. This article reviews clinical applications of volumetric multimodal CT that helped to guide and manage care.

  1. Patient doses using multidetector computed tomography scanners in Kenya.

    PubMed

    Korir, G K; Wambani, J S; Korir, I K

    2012-08-01

    Assessment of patient dose attributed to multislice computed tomography (CT) examination. A questionnaire method was developed and used in recording the patient dose and scanning parameters for the head, chest, abdomen and lumbar spine examinations. The patient doses due to brain, chest and abdomen examination were above the international diagnostic reference levels (DRLs) by factors of between one and four. The study demonstrated that the use of multislice CT elevates patient radiation dose, justifying the need for local optimised scanning protocols and the use of institutional DRL for dose management without affecting diagnostic image quality.

  2. Sex estimation from sternal measurements using multidetector computed tomography.

    PubMed

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation.

  3. Sex Estimation From Sternal Measurements Using Multidetector Computed Tomography

    PubMed Central

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-01-01

    Abstract We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation. Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30–60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation. PMID:25501090

  4. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations*

    PubMed Central

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. PMID:27403020

  5. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations.

    PubMed

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  6. Computed tomography angiography: state-of-the-art imaging using multidetector-row technology.

    PubMed

    Napoli, Alessandro; Fleischmann, Dominik; Chan, Frandics P; Catalano, Carlo; Hellinger, Jeffrey C; Passariello, Roberto; Rubin, Geoffrey D

    2004-01-01

    Multidetector-row computed tomography (MDCT) is an essential diagnostic modality for many clinical algorithms. This is particularly true with regard to the evaluation of cardiovascular disease. As a result of increased image acquisition speed, improved spatial resolution, and greater scan volume, MDCT angiography (computed tomography angiography [CTA]) has become an excellent noninvasive imaging technique, replacing intra-arterial digital subtraction angiography for most vascular territories. The clinical success of CTA depends on precise synchronization of image acquisition with optimal vascular enhancement. As technology continuously evolves, however, this task can be challenging. It remains important to have a fundamental knowledge of the principles behind technical parameters and contrast medium administration. This article reviews these essential principles, followed by an overview of current clinical applications.

  7. An Unusual Left Ventricular Outflow Pseudoaneurysm: Usefulness of Echocardiography and Multidetector Computed Tomography for Surgical Repair

    SciTech Connect

    Da Col, Uberto; Ramoni, Enrico Di Bella, Isidoro; Ragni, Temistocle

    2009-01-15

    Left ventricular outflow tract (LVOT) pseudoaneurysm is a rare but potentially lethal complication, mainly after aortic root endocarditis or surgery. Usually it originates from a dehiscence in the mitral-aortic intervalvular fibrosa and it arises posteriorly to the aortic root. Due to these anatomical features, its imaging assessment is challenging and surgical repair requires complex procedures. An unusual case of LVOT pseudoaneurysm is described. It was detected by transthoracic ecocardiography 7 months after aortic root replacement for acute endocarditis. Multidetector computed tomography (MDCT) confirmed the presence of a pouch located between the aortic root and the right atrium. Computed tomography also detected the origin of the pseudoaneurysm from the muscular interventricular septum of the LVOT, rather below the aortic valve plane. It was repaired with an extracardiac surgical approach, sparing the aortic root bioprosthesis previously implanted. The high-resolution three-dimensional details provided by the preoperative MDCT allowed us to plan a simple and effective surgical strategy.

  8. Focused assessment with sonography for trauma (FAST) versus multidetector computed tomography in hemodynamically stable emergency patients.

    PubMed

    Fornell Pérez, R

    2017-02-10

    This critically appraised topic (CAT) study aims to evaluate the quality and extent of the scientific evidence that supports the use of focused assessment with sonography for trauma (FAST) versus multidetector computed tomography (MDCT) in hemodynamically stable trauma patients in the emergency room. An efficient search of the literature yielded several recent articles with a high level of evidence. The CAT study concludes that FAST is an acceptable initial imaging test in hemodynamically stable patients, although its performance is limited in certain circumstances. The decision whether to use MDCT should be determined by evaluating the patient's degree of instability and the distance to the MDCT scanner. Nevertheless, few articles address the question of the distance to MDCT scanners in emergency departments.

  9. [Evaluation of cardiac tumors by multidetector computed tomography and magnetic resonance imaging].

    PubMed

    Mercado-Guzman, Marcela P; Meléndez-Ramírez, Gabriela; Castillo-Castellon, Francisco; Kimura-Hayama, Eric

    Cardiac tumors, are a rare pathology (0.002-0.3%) in all age groups, however, they have a clinic importance, due the affected organ. They are classified in primary (benign or malignant) and secondary (metastasis) types. Among primary type, mixoma, is the most common benign tumor, and sarcoma represents most of the malignant injuries. Cardiac metastasis are more frequent than primary tumors. Clinic effects of cardiac tumors are unspecific and vary according their location, size and agresivity. The use of Multidetector Computed Tomography (MDCT) and Magnetic Resonance Imaging (MRI) assist on the location, sizing, anatomical relationships and the compromise of adyacents structures, besides, MRI is useful for tissue characterization of the tumor. Due to the previous reasons, studies based on noninvasive cardiovascular imaging, have an important role on the characterization of these lesions and the differential diagnosis among them.

  10. [Review of pre- and post-treatment multidetector computed tomography findings in abdominal aortic aneurysms].

    PubMed

    Casula, E; Lonjedo, E; Cerverón, M J; Ruiz, A; Gómez, J

    2014-01-01

    The increase in the frequency of abdominal aortic aneurysms (AAA) and the widely accepted use of endovascular aneurysm repair (EVAR) as a first-line treatment or as an alternative to conventional surgery make it necessary for radiologists to have thorough knowledge of the pre- and post-treatment findings. The high image quality provided by multidetector computed tomography (MDCT) enables CT angiography to play a fundamental role in the study of AAA and in planning treatment. The objective of this article is to review the cases of AAA in which CT angiography was the main imaging technique, so that radiologists will be able to detect the signs related to this disease, to diagnose it, to plan treatment, and to detect complications in the postoperative period.

  11. Diagnostic Yield of Multidetector Computed Tomography in Patients with Acute Spondylodiscitis.

    PubMed

    Rausch, Vanessa Hanna; Bannas, Peter; Schoen, Gerhard; Froelich, Andreas; Well, Lennart; Regier, Marc; Adam, Gerhard; Henes, Frank Oliver Gerhard

    2017-03-01

    Purpose To determine the value of multidetector computed tomography (MDCT) in patients with acute spondylodiscitis. Methods and Materials For data acquisition, we searched our radiological database for all patients who had undergone magnetic resonance imaging (MRI) for suspected spondylodiscitis between 2007 and 2015 (n = 325). For further analyses, we included all patients (n = 67) who initially underwent MDCT prior to MRI. Overall accuracy, sensitivity, specificity and positive and negative predictive values were calculated for MDCT and, separately, for contrast-enhanced CT (CECT, n = 36) and for non-enhanced CT (NECT, n = 31). MRI together with clinical evaluation served as the standard of reference.

  12. Comparison of in vivo cone-beam and multidetector computed tomographic scans by three-dimensional merging software.

    PubMed

    Rostetter, Claudio; Metzler, Philipp; Schenkel, Jan S; Seifert, Burkhardt; Luebbers, Heinz-Theo

    2015-12-01

    In dentomaxillofacial radiology, cone-beam computed tomography (CT) is used to give fast and high-resolution 3-dimensional images of bone with a low dose of radiation. However, its use for quantitative measurement of bone density based on absolute values (Hounsfield units, HU) as in multidetector CT is still controversial. We know of no in vivo study of 3-dimensional merging software that will reliably match identical bone areas of cone-beam and multidetector CT datasets. We studied 19 multidetector, and 19 cone-beam, CT scans of the skull. The two datasets were fused, corresponding points were identified for measurement, and we compared mean density. We used linear regression to analyse the relation between the two different scanning methods, and studied a total of 4180 measurements. The mean time interval between scans was 5.2 (4.7) months. Mean R(2) over all measurements was 0.63 (range 0.22 - 0.79) with a mean internal consistency (Cronbach's α) of 0.86 (range 0.61 - 0.93). The strongest linearity, seen at the left mastoid, was R(2)=0.79 with high internal consistency (Cronbach's α 0.89), and the weakest was at the left zygomatic bone with R(2)=0.22 and Cronbach's α=0.61. Measurements of bone density based on cone-beam and multidetector CT scans generated in vivo showed high and reproducible internal consistency but poor linearity.

  13. Comparison of the Diagnostic Image Quality of the Canine Maxillary Dentoalveolar Structures Obtained by Cone Beam Computed Tomography and 64-Multidetector Row Computed Tomography.

    PubMed

    Soukup, Jason W; Drees, Randi; Koenig, Lisa J; Snyder, Christopher J; Hetzel, Scott; Miles, Chanda R; Schwarz, Tobias

    2015-01-01

    The objective of this blinded study was to validate the use of cone beam computed tomography (C) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methylmethacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxillary segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT.

  14. Quadricuspid pulmonary valve in an adult patient identified by transthoracic echocardiography and multi-detector computed tomography.

    PubMed

    Jung, Soo-Yeon

    2015-01-01

    Quadricuspid pulmonary valve is a rare congenital heart disease. It is infrequently associated with significant clinical complications and tends to be clinically silent. Because of its benign nature, it has been diagnosed mainly post mortem. Its diagnosis by transthoracic echocardiography is very difficult because of the anatomical features. We describe a case of quadricuspid pulmonary valve diagnosed by transthoracic echocardiography and electrocardiography-gated multi-detector row computed tomography.

  15. Evaluation of cardiovascular anomalies in patients with asymptomatic turner syndrome using multidetector computed tomography.

    PubMed

    Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin; Chung, Woo Yeong

    2013-08-01

    Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed.

  16. Colonic perforation by a transmural and transvalvular migrated retained sponge: multi-detector computed tomography findings.

    PubMed

    Camera, Luigi; Sagnelli, Marco; Guadagno, Paolo; Mainenti, Pier Paolo; Marra, Teresa; Scotto di Santolo, Maria; Fei, Landino; Salvatore, Marco

    2014-04-21

    Transmural migrated retained sponges usually impact at the level of the ileo-cecal valve leading to a small bowel obstruction. Once passed through the ileo-cecal valve, a retained sponge can be propelled forward by peristaltic activity and eliminated with feces. We report the case of a 52-year-old female with a past surgical history and recurrent episodes of abdominal pain and constipation. On physical examination, a generalized resistance was observed with tenderness in the right flank. Contrast-enhanced multi-detector computed tomography findings were consistent with a perforated right colonic diverticulitis with several out-pouchings at the level of the ascending colon and evidence of free air in the right parieto-colic gutter along with an air-fluid collection within the mesentery. In addition, a ring-shaped hyperdense intraluminal material was also noted. At surgery, the ascending colon appeared irregularly thickened and folded with a focal wall interruption and a peri-visceral abscess at the level of the hepatic flexure, but no diverticula were found. A right hemi-colectomy was performed and on dissection of the surgical specimen a retained laparotomy sponge was found in the bowel lumen.

  17. Associations Between Cardio-Ankle Vascular Index and Aortic Structure and Sclerosis Using Multidetector Computed Tomography.

    PubMed

    Horinaka, Shigeo; Yagi, Hiroshi; Fukushima, Hiromichi; Shibata, Yoshimasa; Takeshima, Hiroshi; Ishimitsu, Toshihiko

    2017-04-01

    Aortic pulse wave velocity (PWV) has been accepted as the gold standard for arterial stiffness measurement. However, PWV depends on blood pressure (BP). To eliminate the BP dependency of PWV, the cardio-ankle vascular index (CAVI) was developed. This study aimed to define the relationship between CAVI and aortic atherosclerosis or structure on multidetector computed tomography (MDCT). Patients with (n = 49) or without (n = 49) coronary artery disease were studied. The lumen and vessel diameters and wall thickness were calculated from the cross-sectional area at the pulmonary bifurcation level by 64-slice MDCT. The CAVI was measured within 3 days before MDCT. Multivariate analysis showed that the vessel diameter of the ascending and descending aorta on MDCT depends on age, body surface area, and diastolic BP. The CAVI significantly correlated with the vessel diameter ( r = .453) and wall thickness ( r = .387) of the thoracic descending aorta ( P < .001, respectively). The CAVI was an independent predictor of the descending aortic wall thickness on multiple stepwise regression analysis. These data suggest that CAVI, a simple index, is useful for evaluating thoracic aortic atherosclerosis.

  18. A case of bilateral tracheal bronchus: report of a rare association in multidetector computed tomography bronchoscopy.

    PubMed

    Wooten, Candace; Doros, Caius; Miclaus, Gratian D; Matusz, Petru; Loukas, Marios

    2015-08-01

    Bilateral tracheal bronchus is a rare variation of the tracheobronchial tree. We present a 1-year 7-month-old male patient who presented with sepsis following endotracheal intubation. Upon review of multidetector computed tomography images, the patient was diagnosed with displaced bilateral tracheal bronchus. Imaging showed a right-sided anomalous bronchus arising 0.9 cm proximal to the carina. The left-sided anomalous bronchus arose 0.7 cm proximal to the carina, mimicking a tracheal trifurcation. When viewed together, the close proximity of both the right and left tracheal bronchi to the carina created a distinct tracheal quadrifurcation. This rare anatomic variation was additionally associated with an anorectal malformation (anal atresia). Unrecognized tracheal bronchus in patients undergoing endotracheal intubation can lead to serious complications. While bilateral tracheal bronchus is described in the literature, we are unaware of any case similar to this patient presentation. We present and analyze this unusual case of bilateral tracheal bronchus. The anatomy and clinical significance of this variation is then discussed.

  19. A Structural and Functional Assessment of the Lung via Multidetector-Row Computed Tomography

    PubMed Central

    Hoffman, Eric A.; Simon, Brett A.; McLennan, Geoffrey

    2006-01-01

    With advances in multidetector-row computed tomography (MDCT), it is now possible to image the lung in 10 s or less and accurately extract the lungs, lobes, and airway tree to the fifth- through seventh-generation bronchi and to regionally characterize lung density, texture, ventilation, and perfusion. These methods are now being used to phenotype the lung in health and disease and to gain insights into the etiology of pathologic processes. This article outlines the application of these methodologies with specific emphasis on chronic obstructive pulmonary disease. We demonstrate the use of our methods for assessing regional ventilation and perfusion and demonstrate early data that show, in a sheep model, a regionally intact hypoxic pulmonary vasoconstrictor (HPV) response with an apparent inhibition of HPV regionally in the presence of inflammation. We present the hypothesis that, in subjects with pulmonary emphysema, one major contributing factor leading to parenchymal destruction is the lack of a regional blunting of HPV when the regional hypoxia is related to regional inflammatory events (bronchiolitis or alveolar flooding). If maintaining adequate blood flow to inflamed lung regions is critical to the nondestructive resolution of inflammatory events, the pathologic condition whereby HPV is sustained in regions of inflammation would likely have its greatest effect in the lung apices where blood flow is already reduced in the upright body posture. PMID:16921136

  20. Structural Comparison between the Right and Left Atrial Appendages Using Multidetector Computed Tomography

    PubMed Central

    Shinoda, Koichi; Fukuoka, Daisuke; Torii, Ryo; Watanabe, Tsuneo; Nakano, Takashi

    2016-01-01

    The three-dimensional (3D) structures of the right atrial appendage (RAA) and left atrial appendage (LAA) were compared to clarify why thrombus formation less frequently occurs in RAA than in LAA. Morphological differences between RAA and LAA of 34 formalin-preserved cadaver hearts were investigated. Molds of RAA and LAA specimens were made and the neck areas, volumes of the atrial appendages (AA), and amount of pectinate muscles (PMs) were analyzed using multidetector computed tomography. In RAA, most PMs were connected to one another and formed a “dendritic” appearance and the inner surface area was smaller than in LAA. RAA had smaller volumes and larger neck areas than LAA. The ratios of the neck area/volume were larger and the amounts of PMs were smaller in RAA than in LAA. The volumes, neck areas, and amount of PMs of RAA were significantly correlated with those of LAA. According to the 3D structure, RAA appears to be suited for a more favorable blood flow, which may explain why the thrombus formation is less common in RAA than in LAA. Examining not only LAA but also RAA by transesophageal echocardiography may be useful in high-risk patients of thrombus formation in LAA because the volume, neck area, and amount of PMs of LAA reflect the shape of RAA. PMID:27900330

  1. Advances of multidetector computed tomography in the characterization and staging of renal cell carcinoma

    PubMed Central

    Tsili, Athina C; Argyropoulou, Maria I

    2015-01-01

    Renal cell carcinoma (RCC) accounts for approximately 90%-95% of kidney tumors. With the widespread use of cross-sectional imaging modalities, more than half of RCCs are detected incidentally, often diagnosed at an early stage. This may allow the planning of more conservative treatment strategies. Computed tomography (CT) is considered the examination of choice for the detection and staging of RCC. Multidetector CT (MDCT) with the improvement of spatial resolution and the ability to obtain multiphase imaging, multiplanar and three-dimensional reconstructions in any desired plane brought about further improvement in the evaluation of RCC. Differentiation of RCC from benign renal tumors based on MDCT features is improved. Tumor enhancement characteristics on MDCT have been found closely to correlate with the histologic subtype of RCC, the nuclear grade and the cytogenetic characteristics of clear cell RCC. Important information, including tumor size, localization, and organ involvement, presence and extent of venous thrombus, possible invasion of adjacent organs or lymph nodes, and presence of distant metastases are provided by MDCT examination. The preoperative evaluation of patients with RCC was improved by depicting the presence or absence of renal pseudocapsule and by assessing the possible neoplastic infiltration of the perirenal fat tissue and/or renal sinus fat compartment. PMID:26120380

  2. Multidetector row computed tomography evaluation of potential living laparoscopic renal donors: the story so far.

    PubMed

    Namasivayam, Saravanan; Kalra, Mannudeep K; Small, William C; Torres, William E; Mittal, Pardeep K

    2006-01-01

    Renal transplantation is the treatment of choice for end-stage renal disease. Living related kidney donation is the major source of renal grafts due to limited availability of cadaveric kidneys. Open nephrectomy was used to harvest donor kidneys. However, the laparoscopic approach is associated with less postoperative pain and quick recovery. So, most centers now prefer a laparoscopic approach to explant donor kidneys. Laparoscopic approach is technically challenging due to limited operative visibility. Hence, accurate preoperative detection of renal arterial and venous anomalies is imperative to avoid inadvertent vascular injury and bleeding. The preoperative workup of renal donors includes clinical evaluation, laboratory tests, and imaging. Traditionally, the renal donors were evaluated with conventional imaging techniques, which included renal catheter angiography and intravenous urography. However, conventional imaging is invasive, expensive, and less accurate for evaluation of complex renal venous anomalies, small calculi, and diffuse or focal renal parenchymal lesions. The introduction of multidetector row computed tomography (MDCT) revolutionized the CT technology by enabling isotropic resolution with faster scan coverage in a single, short breath-hold. Consequently, MDCT has now replaced conventional imaging for comprehensive imaging of potential living renal donors. MDCT is a minimally invasive technique that can accurately detect urolithiasis, renal arterial and venous anomalies, renal parenchymal lesions, and urinary tract anomalies. Renal vascular anomalies detected by MDCT can help the surgeon in planning donor nephrectomy. MDCT with three-dimensional CT angiography enables accurate preoperative renal vascular mapping. This article reviews the role of MDCT in preoperative evaluation of potential laparoscopic renal donors.

  3. Morphometric analysis of sex differences in contemporary Japanese pelves using multidetector computed tomography.

    PubMed

    Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Yamaguchi, Rutsuko; Hashimoto, Mari; Hoshioka, Yumi; Iwase, Hirotaro

    2015-12-01

    Sex estimation of decomposed or skeletal remains is clearly important in forensic contexts. Recently, contemporary population-specific data has been obtained using multidetector computed tomography (MDCT) scanning. The main purpose of this study was to investigate skeletal pelvic dimorphism in a contemporary Japanese forensic sample and to quantify the accuracy of sex estimation using various pelvic measurements obtained from three-dimensional (3D) CT images. This study used a total of 208 cadavers (104 males, 104 females) of which postmortem CT scanning and subsequent forensic autopsy were conducted between December 2011 and August 2014. Eleven measurements of each pelvis were obtained from 3D CT reconstructed images that extracted only bone data. The measurements were analyzed using descriptive statistics and discriminant function analyses. All except one measurement were dimorphic in terms of sex differences. Univariate discriminant function analyses using these measurements provided sex classification accuracy rates of 62.0-98.1%. The subpubic angle was found to contribute most significantly to accurate sex estimation. Multivariate discriminant functions yielded sex prediction accuracy rates of 63.9-98.1%. In conclusion, the pelvic measurements obtained from 3D CT images of a contemporary Japanese population successfully demonstrated sexual dimorphism and may be useful for the estimation of skeletal sex in the field of forensic anthropology.

  4. Multidetector computed tomography analysis of benign and malignant nodules in patients with chronic lymphocytic thyroiditis.

    PubMed

    Zhu, Caisong; Liu, Wei; Yang, Jun; Yang, Jing; Shao, Kangwei; Yuan, Lixin; Chen, Hairong; Lu, Wei; Zhu, Ying

    2016-07-01

    The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (P<0.05). MDCT features such as ill-defined margin, absence of capsule or incomplete capsule or homogeneous enhancement were more likely to be present in the malignant nodules (P<0.05). Nevertheless, no significant difference was observed in the enhancement degree at arterial or venous phase between benign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice.

  5. Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

    PubMed

    Valentin, J

    2007-01-01

    Computed tomography (CT) technology has changed considerably in recent years with the introduction of increasing numbers of multiple detector arrays. There are several parameters specific to multi-detector computed tomography (MDCT) scanners that increase or decrease patient dose systematically compared to older single detector computed tomography (SDCT) scanners. This document briefly reviews the MDCT technology, radiation dose in MDCT, including differences from SDCT and factors that affect dose, radiation risks, and the responsibilities for patient dose management. The document recommends that users need to understand the relationship between patient dose and image quality and be aware that image quality in CT is often higher than that necessary for diagnostic confidence. Automatic exposure control (AEC) does not totally free the operator from selection of scan parameters, and awareness of individual systems is important. Scanning protocols cannot simply be transferred between scanners from different manufacturers and should be determined for each MDCT. If the image quality is appropriately specified by the user, and suited to the clinical task, there will be a reduction in patient dose for most patients. Understanding of some parameters is not intuitive and the selection of image quality parameter values in AEC systems is not straightforward. Examples of some clinical situation shave been included to demonstrate dose management, e.g. CT examinations of the chest, the heart for coronary calcium quantification and non-invasive coronary angiography, colonography, the urinary tract, children, pregnant patients, trauma cases, and CT guided interventions. CT is increasingly being used to replace conventional x-ray studies and it is important that patient dose is given careful consideration, particularly with repeated or multiple examinations.

  6. Clinical significance of multidetector-row computed tomography in breast surgery.

    PubMed

    Doihara, Hiroyoshi; Fujita, Takeo; Takabatake, Daisuke; Takahashi, Hirotoshi; Ogasawara, Yutaka; Shimizu, Nobuyoshi

    2006-01-01

    Several reports support the association of higher ipsilateral breast tumor recurrence rates with positive or intermediate margins compared with negative pathologic margins. Precise evaluation of tumor extension and adequate surgical margin are important factors affecting tumor recurrence after breast-conserving surgery (BCS). Many studies have reported the utility of magnetic resonance imaging (MRI) for diagnosing the tumor extension of breast cancer, but few have evaluated the utility of multidetector-row computed tomography (MDCT). The results of this study show the clinical significance of MDCT for detecting cancer extension and demonstrate the clinical role of MDCT in BCS. Subjects comprised 136 patients grouped into two categories based on whether or not tumor extension was evaluated with MDCT preoperatively. The positive surgical margin rate and breast conservation rate were analyzed in each group and the clinical role of MDCT in BCS was evaluated. Moreover, evaluation of intraductal extension was done both with MDCT and histologically, and computed tomography (CT)-pathologic correlations were examined retrospectively. Finally, the margin-positive cases were analyzed in relation to their clinical characteristics. Sensitivity, specificity, positive predictive value, and negative predictive value for detection of the intraductal component were 71.8%, 85.7%, 82.1%, and 76.9%, respectively. The positive surgical margin rate and conservation rate are 7.46% and 81.9%, respectively, for those who were diagnosed with MDCT preoperatively; their corresponding rates without MDCT were 16.67% and 67.9%. Most margin-positive patients have remarkable lymphatic space invasion. Positive surgical margins were often recognized toward the nipple. For diagnosing the intraductal extension, MDCT shows sufficient diagnosability. Moreover, MDCT can provide appropriate information for the determination of adequate surgical margins and contribute to increases in breast conservation

  7. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants *

    PubMed Central

    Araujo Neto, Severino Aires; de Mello Júnior, Carlos Fernando; Franca, Henrique Almeida; Duarte, Cláudia Martina Araújo; Borges, Rafael Farias; de Magalhães, Ana Guardiana Ximenes

    2016-01-01

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. PMID:26929461

  8. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants.

    PubMed

    Araujo Neto, Severino Aires; de Mello Júnior, Carlos Fernando; Franca, Henrique Almeida; Duarte, Cláudia Martina Araújo; Borges, Rafael Farias; de Magalhães, Ana Guardiana Ximenes

    2016-01-01

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications.

  9. Multidetector computed tomography in the evaluation of pediatric acute abdominal pain in the emergency department.

    PubMed

    Lin, Wei-Ching; Lin, Chien-Heng

    2016-06-01

    The accurate diagnosis of pediatric acute abdominal pain is one of the most challenging tasks in the emergency department (ED) due to its unclear clinical presentation and non-specific findings in physical examinations, laboratory data, and plain radiographs. The objective of this study was to evaluate the impact of abdominal multidetector computed tomography (MDCT) performed in the ED on pediatric patients presenting with acute abdominal pain. A retrospective chart review of children aged <18 years with acute abdominal pain who visited the emergency department and underwent MDCT between September 2004 and June 2007 was conducted. Patients with a history of trauma were excluded. A total of 156 patients with acute abdominal pain (85 males and 71 females, age 1-17 years; mean age 10.9 ± 4.6 years) who underwent abdominal MDCT in the pediatric ED during this 3-year period were enrolled in the study. One hundred and eighteen patients with suspected appendicitis underwent abdominal MDCT. Sixty four (54.2%) of them had appendicitis, which was proven by histopathology. The sensitivity of abdominal MDCT for appendicitis was found to be 98.5% and the specificity was 84.9%. In this study, the other two common causes of nontraumatic abdominal emergencies were gastrointestinal tract (GI) infections and ovarian cysts. The most common etiology of abdominal pain in children that requires imaging with abdominal MDCT is appendicitis. MDCT has become a preferred and invaluable imaging modality in evaluating uncertain cases of pediatric acute abdominal pain in ED, in particular for suspected appendicitis, neoplasms, and gastrointestinal abnormalities.

  10. Multidetector Computed Tomography and Magnetic Resonance Imaging Evaluation of Craniovertebral junction Abnormalities

    PubMed Central

    Dhadve, Rajshree U.; Garge, Shaileshkumar S.; Vyas, Pooja D.; Thakker, Nirav R.; Shah, Sonali H.; Jaggi, Sunila T.; Talwar, Inder A.

    2015-01-01

    Background: Craniovertebral junction (CVJ) abnormalities constitute an important group of treatable neurological disorders with diagnostic dilemma. Their precise diagnosis, identification of probable etiology, and pretreatment evaluation significantly affects prognosis and quality of life of patients. Aims: The study was to classify various craniovertebral junction disorders according to their etiology and to define the importance of precise diagnosis for pretreatment evaluation with multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI). Materials and Methods: This is a prospective observational study of 62 patients referred to our department between October 2012 and September 2014. All patients suspected to have a craniovertebral junction disorder were included in the study, from all age groups and both genders. Detailed clinical history was taken. Radiographs of cervical spine were collected if available. All patients were subjected to MDCT and/or MRI. Results: In our study of 62 patients; 39 were males and 23 were females, with male to female ratio of 1.6:1. Most common age group was 2nd -3rd decade (19 patients, 30.64%). Developmental anomalies (33 patients, 53.22%) were the most common etiology group followed by traumatic (10 patients, 16.12%), degenerative (eight patients, 12.90%), infective (four patients, 6.45%), inflammatory and neoplastic (three patients each, 4.8%), and no cause found in one patient. Conclusions: CVJ abnormalities constitute an important group of treatable neurological disorders, especially in certain ethnic groups and are approached with much caution by clinicians. Thus, it is essential that radiologists should be able to make a precise diagnosis of craniovertebral junction abnormalities, classify them into etiological group, and rule out important mimickers on MDCT and/or MRI, as this information ultimately helps determine the management of such abnormalities, prognosis, and quality of life of patients. PMID

  11. Is multidetector computed tomography comparable to magnetic resonance imaging for assessment of lumbar foraminal stenosis?

    PubMed

    Kang, Woo Young; Ahn, Joong Mo; Lee, Joon Woo; Lee, Eugene; Bae, Yun Jung; Seo, Jiwoon; Kim, Junghoon; Kang, Heung Sik

    2017-02-01

    Background Both multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) are used for assessment of lumbar foraminal stenosis (LFS). Therefore, it is relevant to assess agreement between these imaging modalities. Purpose To determine intermodality, inter-, and intra-observer agreement for assessment of LFS on MDCT and MRI. Material and Methods A total of 120 foramina in 20 patients who visited our institution in January and February 2014 were evaluated by six radiologists with different levels of experience. Radiologists evaluated presence and severity of LFS on sagittal CT and MR images according to a previously published LFS grading system. Intermodality agreement was analyzed by using weighted kappa statistics, while inter- and intra-observer agreement were analyzed by using intraclass correlation coefficients (ICCs) and kappa statistics. Results Overall intermodality agreement was moderate to good (kappa, 0.478-0.765). In particular, two professors and one fellow tended to overestimate the degree of LFS on CT compared with MRI. For inter-observer agreement of all six observers, ICCs indicated excellent agreement for both CT (0.774) and MRI (0.771), while Fleiss' kappa values showed moderate agreement for CT (0.482) and MRI (0.575). There was better agreement between professors and fellows compared with residents. For intra-observer agreement, ICCs indicated excellent agreement, while kappa values showed good to excellent agreement for both CT and MRI. Conclusion MDCT was comparable to MRI for diagnosis and assessment of LFS, especially for experienced observers. However, there was a tendency to overestimate the degree of LFS on MDCT compared with MRI.

  12. Using the 320-Multidetector Computed Tomography scanner for four-dimensional functional assessment of the elbow joint.

    PubMed

    Goh, Yin Peng; Lau, Kenneth K

    2012-02-01

    As described in this case report, the use of the 320-Multidetector Computed Tomography scanner (Aquilion One, Toshiba Medical Systems, Japan) to produce continuous 3-dimensional images in real time, over a distance of 16 cm in the z-axis, proved to aid in the diagnosis of a patient's restrictive elbow joint. This state-of-the-art scanner allows fast and noninvasive dynamic-kinematic functional evaluation of the elbow joint in vivo. It will also be applicable to kinematic studies of other joints.

  13. Dynamic multidetector computed tomography findings of hepatocellular carcinoma of hepatitis B virus-positive and -negative patients

    PubMed Central

    2014-01-01

    Background The objective of this study was to retrospectively investigate and compare multidetector computed tomography findings of hepatocellular carcinoma (HCC) in hepatitis B virus (HBV)-positive and -negative patients. Methods Triphasic (arterial, portal venous, and delayed phases) dynamic multidetector computed tomography (CT) was performed in 83 patients with HCC, 48 of whom were HBV-positive. The diagnosis of HCC was established with typical CT imaging findings (68 patients) or histopathological evaluation (15 patients). Distribution of solitary, multiple, and diffuse HCC, portal/hepatic vein thrombosis, metastasis, and patients with high alpha-fetoprotein levels in the HBV-positive and -negative groups were compared using the Kolmogorov–Smirnov test. Lesion size, alpha-fetoprotein levels, arterial, portal, delayed enhancement, and washout of lesions were compared using the Student’s t-test. Results Hypervascular tumors were observed in 72 (87%) patients, and hypovascular tumors were found in 11 (13%) patients. The mean alpha-fetoprotein value of HBV-positive patients with HCC was significantly higher than the mean alpha-fetoprotein value of HBV-negative patients (P < 0.05). Portal/hepatic vein thrombosis and metastasis were more frequently observed in HBV-positive patients (P < 0.05). The frequencies of solitary, multiple, and diffuse lesions in HBV-positive and -negative patients were not significantly different (P > 0.05). The mean diameters, arterial, portal, and delayed phase attenuations, and washout of HCC were not significantly different (P > 0.05). Conclusions Multidetector CT imaging findings of HCC in HBV-positive and -negative patients are alike. Portal/hepatic vein thrombosis and metastasis are more frequently observed in HBV-positive patients. Alpha-fetoprotein levels are higher in HBV-positive patients. PMID:25608603

  14. Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners

    SciTech Connect

    Mathieu, Kelsey B.; McNitt-Gray, Michael F.; Zhang, Di; Kim, Hyun J.; Cody, Dianna D.

    2010-08-15

    Purpose: Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and models of multidetector row CT (MDCT) scanners. Methods: Physical measurements were collected using nine CT scanners (three scanners each of GE VCT, GE LightSpeed 16, and Siemens Sensation 64 CT). Measurements were made using various combinations of technical factors, including kVp, type of bowtie filter, and x-ray beam collimation, for several dosimetry-related quantities, including (a) free-in-air CT dose index (CTDI{sub 100,air}); (b) calculated half-value layers and quarter-value layers; and (c) weighted CT dose index (CTDI{sub w}) calculated from exposure measurements collected in both a 16 and 32 cm diameter CTDI phantom. Data collection was repeated at several different time intervals, ranging from seconds (for CTDI{sub 100,air} values) to weekly for 3 weeks and then quarterly or triannually for 1 yr. Precision of the data was quantified by the percent coefficient of variation (%CV). Results: The maximum relative precision error (maximum %CV value) across all dosimetry metrics, time periods, and scanners included in this study was 4.33%. The median observed %CV values for CTDI{sub 100,air} ranged from 0.05% to 0.19% over several seconds, 0.12%-0.52% over 1 week, and 0.58%-2.31% over 3-4 months. For CTDI{sub w} for a 16 and 32 cm CTDI phantom, respectively, the range of median %CVs was 0.38%-1.14% and 0.62%-1.23% in data gathered weekly for 3 weeks and 1.32%-2.79% and 0.84%-2.47% in data gathered quarterly or triannually for 1 yr. Conclusions: From a dosimetry perspective, the MDCT scanners tested in this study demonstrated a high degree of within-run, between-run, and between-scanner precision (with relative precision errors typically well

  15. Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

    PubMed Central

    Eskandarloo, Amir; Noruzi-Gangachin, Maruf; Khajeh, Samira

    2015-01-01

    Objectives This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended. PMID:25671214

  16. Validation of a paediatric thyroid phantom using different multidetector computed tomography models

    NASA Astrophysics Data System (ADS)

    Alsabbagh, M.; Ng, L. Y.; Tajuddin, A. A.; Manap, M. A.; Zainon, R.

    2016-03-01

    The aim of this study was to compare the attenuation values of a fabricated paediatric thyroid phantom material using different MDCT models. A paediatric thyroid phantom was designed to mimic the shape and size of a paediatric patient with an age of 9 years using high- density Polyethylene as the phantom material. The fabricated phantom was scanned using two different multidetector CT scanners (16- and 128-row detectors). The CT numbers were evaluated and the mass attenuation coefficients (μ/ρ) of the phantom material were obtained at each applied energy from each scanner. The results were compared with the tables of the National Institute of Standards and Technology (NIST). The CTs of 16- and 128-row detectors showed that the obtained attenuation values are very similar to the NIST's values. However, the CT of the 128-row detectors showed a slightly much closer match to the NIST's values. This refers to the type and quality of the electronic connections between the detectors. Furthermore, the type and number of detectors (16- and 128-detectors) could affect the details and quality of the output images. The results show that different multidetector CTs can be used to validate the phantom and determine the mass attenuation coefficients of its material.

  17. Congenital Variants and Anomalies of the Pancreas and Pancreatic Duct: Imaging by Magnetic Resonance Cholangiopancreaticography and Multidetector Computed Tomography

    PubMed Central

    Erden, Ayşe; Türkoğlu, Mehmet Akif; Yener, Özlem

    2013-01-01

    Though congenital anomalies of the pancreas and pancreatic duct are relatively uncommon and they are often discovered as an incidental finding in asymptomatic patients, some of these anomalies may lead to various clinical symptoms such as recurrent abdominal pain, nausea and vomiting. Recognition of these anomalies is important because these anomalies may be a surgically correctable cause of recurrent pancreatitis or the cause of gastric outlet obstruction. An awareness of these anomalies may help in surgical planning and prevent inadvertent ductal injury. The purpose of this article is to review normal pancreatic embryology, the appearance of ductal anatomic variants and developmental anomalies of the pancreas, with emphasis on magnetic resonance cholangiopancreaticography and multidetector computed tomography. PMID:24265565

  18. A Study of Internal Thoracic Arteriovenous Principal Perforators by Using Multi-detector Row Computed Tomography Angiography

    PubMed Central

    Hashikawa, Kazunobu; Sakakibara, Shunsuke; Onishi, Hiroyuki; Terashi, Hiroto

    2016-01-01

    Objective: There are numerous reports of perforating branches from the intercostal spaces of the internal thoracic vessels. These branches have varying diameters, and a main perforating branch, the principal perforator, most often found in the second or third intercostal space. We report different results based on multi-detector row computed tomography. Methods: We evaluated 121 sides from 70 women scheduled for breast reconstruction with free lower abdominal skin flaps who underwent preoperative multi-detector row computed tomographic scan between June 2008 and June 2015. For primary reconstruction, we analyzed both sides, and for 1-sided secondary reconstruction, we analyzed only the unaffected side. We evaluated both early arterial phase and late venous phase 5-mm horizontal, cross-sectional, and volume-rendering images for perforation sites and internal thoracic arteriovenous perforating branches’ intercostal space thickness. We analyzed differences in thickness between the internal thoracic arteries and veins and symmetry in cases involving both sides. Results: Venous principal perforators nearly always perforated the same intercostal spaces as accompanying veins of arterial principal perforators (99.2%), forming arteriovenous principal perforators. We found 49 principal perforators in the first intercostal space (37.4%), 52 in the second intercostal space (39.7%), 23 in the third intercostal space (17.6%), 6 in the fourth intercostal space (4.6%), and 1 in the fifth intercostal space (0.7%). Of the 51 cases in which we studied both sides, 25 cases (49%) had principal perforators with bilateral symmetry. Conclusions: In contrast to findings from past reports, we found that internal thoracic arteriovenous principal perforators were often present in almost the same numbers in the first and second intercostal spaces. PMID:26958104

  19. Evaluation of the pelvic apophysis with multi-detector computed tomography for legal age estimation in living individuals

    PubMed Central

    Karami, Mehdi; Rabiei, Meisam; Riahinezhad, Maryam

    2015-01-01

    Background: Legal age estimations of living individuals are gaining increasing importance for radiologists involved in delivering expert opinions. The present study aimed to assess the correlation between chronological age and apophyseal centers distance from pelvic bone. Materials and Methods: This was a cross-sectional study carried out on 2013. Subjects were chosen from 15 to 25 years old people who had previous pelvic multi-detector computed tomography for any reason. The distance of iliac crest apophysis to iliac bone, and pubic apophysis to pubic bone were assessed. Results: There was a reverse linear correlation between chronological age and distance of iliac crest apophysis (P < 0.001, r = 0.899) and pubic apophysis to pelvic bone (P < 0.001, r = 0.898). Pubic apophysis was not appeared in subjects before 16 years old and it was appeared in all of the subjects with 18 years old and more. Subjects with age of 21 had near ossification of iliac or pubic apophysis and subjects with age of 24 had full ossification of iliac or pubic apophysis. Conclusion: skeletalage can be estimated by assessing the apophyseal centers distance from the pelvic bone in adolescents 15-25 years old. PMID:26109964

  20. Non-invasive coronary angiography with multi-detector computed tomography: comparison to conventional X-ray angiography.

    PubMed

    Schoenhagen, Paul; Stillman, Arthur E; Halliburton, Sandy S; Kuzmiak, Stacie A; Painter, Tracy; White, Richard D

    2005-02-01

    Selective coronary angiography introduced clinical coronary imaging in the late 1950s. The angiographic identification of high-grade coronary lesions in patients with acute and chronic symptomatic coronary artery disease (CAD) led to the development of surgical and percutaneous coronary revascularization. However, the fact that CAD remains the major cause of death in North America and Europe demonstrates the need for novel, complementary diagnostic strategies. These are driven by the need to characterize both increasingly advanced disease stages but also early, asymptomatic disease development. Complex revascularization techniques for patients with advanced disease stages will initiate a growing demand for 3-dimensional coronary imaging and integration of imaging modalities with new mechanical therapeutic devices. An emerging focus is atherosclerosis imaging with the goal to identify subclinical disease stages as the basis for pharmacological intervention aimed at disease stabilization or reversal. Non-invasive coronary imaging with coronary multidetector computed tomographic angiography (MDCTA) allows both assessment of luminal stenosis and subclinical disease of the arterial wall. Its complementary role in the assessment of early and advanced stages of CAD is increasingly recognized.

  1. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography*

    PubMed Central

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; de Mello Júnior, Carlos Fernando; Silva Neto, Eulâmpio José; Negromonte, Gustavo Ramalho Pessoa; Duarte, Cláudia Martina Araújo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca

    2015-01-01

    Objective To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials and Methods Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. PMID:26811552

  2. Preoperative evaluation value of aortic arch lesions by multidetector computed tomography angiography in type A aortic dissection

    PubMed Central

    Huang, Fang; Chen, Qiang; Lai, Qing-quan; Huang, Wen-han; Wu, Hong; Li, Wei-cheng

    2016-01-01

    Abstract The purpose of this study was to preoperatively evaluate the value of aortic arch lesions by multidetector computed tomography (MDCT) angiography in type A aortic dissection (AD). From January 2013 to December 2015, we enrolled 42 patients with type A AD who underwent MDCT angiography in our hospital. The institutional database of patients was retrospectively reviewed to identify MDCT angiography examinations for type A AD. Surgical corrections were conducted in all patients to confirm diagnostic accuracy. In this study, the diagnostic accuracy of MDCT angiography was 100% in all 42 patients. The intimal tear site locations that were identified in patients included the ascending aorta (n = 25), aortic arch (n = 12), and all other sites (n = 5). Compared with the control group, there were significant differences in the aortic arch anatomy among the cases. Regarding the distance between the left common carotid and left subclavian arteries, compared with the control group, most cases with type A AD had a significant variation. MDCT angiography plays an important role in detecting aortic arch lesions of type A AD, especially in determining the location of the intimal entry site and change of branch blood vessels. Surgeons can formulate an appropriate operating plan, according to the preoperative MDCT diagnosis information. PMID:27684852

  3. MULTIDETECTOR-ROW COMPUTED TOMOGRAPHY PATTERNS OF BRONCHOESPHAGEAL ARTERY HYPERTROPHY AND SYSTEMIC-TO-PULMONARY FISTULA IN DOGS.

    PubMed

    Ledda, Gianluca; Caldin, Marco; Mezzalira, Giorgia; Bertolini, Giovanna

    2015-01-01

    Anomalies involving arterial branches in the lungs are one of the causes of hemoptysis in humans and dogs. Congenital and acquired patterns of bronchoesophageal artery hypertrophy have been reported in humans based on CT characteristics. The purpose of this retrospective study was to describe clinical, echocardiographic, and multidetector computed tomography features of bronchoesophageal artery hypertrophy and systemic-to-pulmonary arterial communications in a sample of 14 dogs. Two main vascular patterns were identified in dogs that resembled congenital and acquired conditions reported in humans. Pattern 1 appeared as an aberrant origin of the right bronchoesophageal artery, normal origin of the left one, and enlargement of both the bronchial and esophageal branches that formed a dense network terminating in a pulmonary artery through an orifice. Pattern 2 appeared as a normal origin of both right and left bronchoesophageal arteries, with an enlarged and tortuous course along the bronchi to the periphery of the lung, where they communicated with subsegmental pulmonary arteries. Dogs having Pattern 1 also had paraesophageal and esophageal varices, with the latter being confirmed by videoendoscopy examination. Authors conclude that dogs with Pattern 1 should be differentiated from dogs with other congenital vascular systemic-to-pulmonary connections. Dogs having Pattern 2 should be evaluated for underlying pleural or pulmonary diseases. Bronchoesophageal artery hypertrophy can be accompanied by esophageal venous engorgement and should be included in the differential diagnosis for esophageal and paraesophageal varices in dogs.

  4. Anatomical variation of celiac axis, superior mesenteric artery, and hepatic artery: Evaluation with multidetector computed tomography angiography

    PubMed Central

    Farghadani, Maryam; Momeni, Mohammad; Hekmatnia, Ali; Momeni, Fateme; Baradaran Mahdavi, Mohammad Mehdi

    2016-01-01

    Background: The celiac axis, superior mesenteric artery (SMA), and hepatic artery are the most important branches of abdominal aorta due to their vascularization field. The aim of our study was to evaluate the prevalence of different anatomical variation of celiac axis, SMA, hepatic artery, and its branches with multidetector computed tomography (MDCT) angiography of upper abdomen arteries. Materials and Methods: MDCT of 607 kidney donor and traumatic patients that referred to MDCT unit at Al Zahra Hospital in Isfahan from 2012 to 2015 were retrospectively evaluated. We excluded patients with history of abdominal vascular surgery and hepatic or pancreatic surgery. Computed tomography images of the patient were obtained with 64-row MDCT scanner and anatomical variations were analyzed. Results: Three hundred and eighty-eight (63.9%) of the 607 patients had classic arterial anatomy and 219 (36.1%) patients had variant types. The most common type of variation was the origin of the right hepatic artery (RHA) from SMA (9.6%), and the next common variation was the origin of the left hepatic artery (LHA) from the left gastric artery (6.9%). Variations in the origin of the common hepatic artery (CHA) were seen in 16 (2.6%) patients. Buhler arc was identified in two patients. The RHA originated from the celiac axis in 11 (1.8%) patients and from the aorta in 8 (1.3%) patients. Trifurcation of CHA into gastroduodenal artery, RHA, and LHA was detected in 11 (1.8%) patients. Conclusion: The results of the present study showed that anatomical variation occurs in a high percentage of patients. Detection of these variations can guide surgical and radiological interventional planning.

  5. Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

    PubMed Central

    2011-01-01

    Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT) was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG)-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional information can be of help

  6. Improvement in the quality of the cardiac vein images by optimizing the scan protocol of multidetector-row computed tomography.

    PubMed

    Hara, Tetsuya; Yamashiro, Kohei; Okajima, Katsunori; Hayashi, Takatoshi; Kajiya, Teishi

    2009-11-01

    The present study aimed at optimizing the scan protocol for multidetector-row computed tomography (MDCT) to adequately visualize coronary veins. Circulation time (Cir.T) was defined as the time period from the injection of contrast media into the coronary artery to the pervasion of the contrast media into the coronary sinus as observed by coronary angiography. We investigated the relation between the Cir.T and echocardiographic parameters in 64 patients. The left ventricular end-diastolic diameter (LVDd) and left ventricular end-systolic diameter (LVDs) were correlated with the Cir.T (r = 0.58, P < 0.0001, and r = 0.60, P < 0.0001 respectively). In addition, the left ventricular ejection fraction (LVEF) was negatively correlated with the Cir.T (r = 0.48, P < 0.0001). The average Cir. T was longer in patients with LVEF < 35% (8.0 s vs 6.7 s; P < 0.05) or LVDd > 55 mm (7.9 s vs 6.2 s; P < 0.05) than in the other patients. The quality of the MDCT images of the coronary veins obtained at different scan timings (coronary artery phase and 10 s or 15 s after the coronary artery phase) were graded and classified into four categories (0 = worst, 3 = best) in 25 patients with LVEF < 35%. The delays of 10 and 15 s after the coronary artery phase significantly improved the mean image quality (P < 0.05). The Cir.T was prolonged in patients with low LVEF and LV dilation. An appropriate delay improved the quality of the MDCT images of the coronary veins in patients with LV dysfunction.

  7. Prediction of Small Bowel Obstruction Caused by Bezoars Using Risk Factor Categories on Multidetector Computed Tomographic Findings

    PubMed Central

    Kuang, Lian-qin; Cheng, Cheng

    2016-01-01

    Objectives. The aim of this study was to detect factors associated with small bowel obstruction (SBO) caused by bezoars on multidetector computed tomographic findings. Methods. We retrospectively reviewed 61 patients who had bezoars in the small bowels on MDCT. The patients were divided into SBO patients group and non-SBO patients group. The mean values of the diameter, volume, and CT attenuation as well as location and characteristics of the bezoars were compared between the two groups. Multivariate analysis was performed to determine factors associated with SBO. Results. There were 32 patients (52.5%) in the SBO group and 29 patients (47.5%) in the non-SBO group. The bezoars in the SBO group had greater values of each mean diameter and mean volume than those in the non-SBO group (3.2 ± 0.5 cm versus 1.6 ± 0.7 cm, P < 0.0001, 14.9 ± 6.4 cm3 versus 2.5 ± 2.7 cm3, P < 0.0001, resp.) and had a lower CT attenuation than the non-SBO group (55.5 ± 23.4 versus 173.0 ± 68.0, P < 0.0001). The SBO group had higher prevalence of phytobezoar appearance (75.0% versus 10.3%, P < 0.0001). Major diameters of bezoar and phytobezoar were significant independent risk factors associated with SBO (odds ratio = 36.09, 8.26, resp., and P = 0.0004, 0.044, resp.). Conclusions. Major diameter of bezoar or phytobezoar is a potential risk factor associated with SBO. PMID:27403434

  8. Assessment of modified Blalock-Taussig shunt in children with congenital heart disease using multidetector-row computed tomography.

    PubMed

    Nabo, Manal Mohamed Helmy; Hayabuchi, Yasunobu; Inoue, Miki; Watanabe, Noriko; Sakata, Miho; Kagami, Shoji

    2010-11-01

    The purpose of this study was to assess the feasibility of multidetector-row computed tomography (MDCT) for the evaluation of modified Blalock-Taussig (B-T) shunt in children with congenital heart disease associated with reduced pulmonary blood flow. A total of 25 consecutive patients (mean age, 2.6 ± 3.6 years; range, 2 months-16 years) underwent MDCT angiography of the thorax with a 16-detector row scanner prior to cardiac catheterization. A total of 39 shunts (right, 22; left, 17) were included in the study. Conventional angiographic findings were used as the gold standard for the detection of B-T shunts. Shunt diameter was measured quantitatively and independently at four sites (the subclavian artery site, the pulmonary artery site, the widest site, and the stenotic site) on MDCT and on conventional invasive angiography. All B-T shunts were depicted on multiplanar reconstruction (MPR), maximum intensity projection (MIP), curved planar reconstruction (CPR), and three-dimensional volume-rendered (VR) images, enabling evaluation in all patients except for one with occluded shunt. There were excellent correlations between MDCT- and conventional angiography-based measurements of shunt diameter at the subclavian artery site, pulmonary artery site, and the widest site (R² = 0.46, 0.74 and 0.64, respectively; p < 0.0001 for each), although systematic overestimation was observed for MDCT (mean percentage of overestimation, 23.1 ± 32.4%). Stenotic site diameter and degree of stenosis showed a mild correlation (R² = 010 and 0.25, respectively; p < 0.01 for each). This study demonstrates that MDCT is a promising tool for the detection of lesions in B-T shunts.

  9. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists

    PubMed Central

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M.

    2016-01-01

    Purpose To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. Methods As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Results Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = < .004). No significant differences were detected concerning the modalities’ specificities (with values between P = .98). Raters' confidence was higher in RED-MDCT and RED-CBCT compared to radiography (P < .001). Conclusion The diagnostic accuracy of RED-MDCT and RED-CBCT for wrist fractures proved to be similar and in some parts even higher compared to radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run. PMID:27788215

  10. Bone Mineral Density Estimations From Routine Multidetector Computed Tomography: A Comparative Study of Contrast and Calibration Effects

    PubMed Central

    Kaesmacher, Johannes; Liebl, Hans; Baum, Thomas; Kirschke, Jan Stefan

    2017-01-01

    Introduction Phantom-based (synchronous and asynchronous) and phantomless (internal tissue calibration based) assessment of bone mineral density (BMD) in routine MDCT (multidetector computed tomography) examinations potentially allows for diagnosis of osteoporosis. Although recent studies investigated the effects of contrast-medium application on phantom-calibrated BMD measurements, it remains uncertain to what extent internal tissue-calibrated BMD measurements are also susceptible to contrast-medium associated density variation. The present study is the first to systemically evaluate BMD variations related to contrast application comparing different calibration techniques. Purpose To compare predicative performance of different calibration techniques for BMD measurements obtained from triphasic contrast-enhanced MDCT. Materials and Methods Bone mineral density was measured on nonenhanced (NE), arterial (AR) and portal-venous (PV) contrast phase MDCT images of 46 patients using synchronous (SYNC) and asynchronous (ASYNC) phantom calibration as well as internal calibration (IC). Quantitative computed tomography (QCT) served as criterion standard. Density variations were analyzed for each contrast phase and calibration technique, and respective linear fitting was performed. Results Both asynchronous calibration-derived BMD values (NE-ASYNC) and values estimated using IC (NE-IC) on NE MDCT images did reasonably well in predicting QCT BMD (root-mean-square deviation, 8.0% and 7.8%, respectively). Average NE-IC BMD was 2.7% lower when compared with QCT (P = 0.017), whereas no difference could be found for NE-ASYNC (P = 0.957). All average BMD estimates derived from contrast-enhanced scans differed significantly from QCT BMD (all P < 0.005) and led to notable systemic BMD biases (mean difference at least > 6.0 mg/mL). All regression fits revealed a consistent linear dependency (R2 range, 0.861–0.963). Overall accuracy and goodness of fit tended to decrease from AR to

  11. Differentiation of Lymphoma Presenting as Retroperitoneal Mass and Retroperitoneal Fibrosis: Evaluation with Multidetector-row Computed Tomography

    PubMed Central

    Zhang, Shuai; Chen, Min; Li, Chun-Mei; Song, Guo-Dong; Liu, Ying

    2017-01-01

    Background: Retroperitoneal fibrosis (RPF) and lymphoma presenting as retroperitoneal mass may closely resemble each other and misdiagnosis may occur. This study investigated the differential imaging features of RPF and lymphoma which presented as a retroperitoneal soft tissue using multidetector-row computed tomography (MDCT). Methods: The 42 consecutive patients were included in this retrospective review, including 19 RPF patients (45.2%; including 13 males and 6 females; mean age: 56.7 ± 6.2 years) and 23 patients with lymphoma (54.8%; including 14 males and 9 females; mean age: 57.4 ± 12.3 years). An array of qualitative computed tomography (CT) features of lesions in 42 consecutive patients with newly diagnosed untreated RPF and lymphoma were retrospectively analyzed. The quantitative size of the lesion at the para-aortic region and attenuation in the precontrast, arterial, and portal phases were calculated in regions of interest and compared between the patients with newly diagnosed untreated RPF and with lymphoma. Receiver operating characteristic curve analysis was used to assess the potential diagnostic value of each quantitative parameter. Inter-reader concordance was also calculated. Results: Mean ages between patients with RPF and lymphoma were not significantly different (56.7 ± 6.2 years vs. 57.4 ± 12.3 years P = 0.595). Compared to those in patients with lymphoma, homogeneous enhancement (65.2% vs. 94.7%, P = 0.027) and pelvic extension (52.2% vs. 89.5%, P = 0.017) were significantly more common while the involvement of additional nodes (78.3% vs. 5.3%, P < 0.001), suprarenal extension (60.9% vs. 15.8%, P = 0.004), and aortic displacement (43.5% vs. 5.3%, P = 0.006) were significantly less common in patients with RPF. Lesion size at the para-aorta was significantly greater in patients with lymphoma, compared with RPF patients (3.9 ± 1.2 cm vs. 1.8 ± 0.6 cm; P < 0.001). The attenuation values in three phases were not significantly different

  12. Three-dimensional image reconstruction of an anorectal malformation with multidetector-row helical computed tomography technology.

    PubMed

    Watanabe, Yoshio; Ando, Hisami; Seo, Takahiko; Kaneko, Kentaro; Katsuno, Shinsuke; Shinohara, Tsuyoshi; Mori, Kensaku; Toriwaki, Junichiro

    2003-05-01

    The presentation of the surgical anatomy of anorectal malformation by standard anatomical figures is not suitable for individual anorectoplasty. It is essential to understand the anatomy of the pelvic muscle (striated muscle complex: SMC) including the external anal sphincter and their three-dimensional (3D) configuration in each patient. Thus, we studied the SMC three-dimensionally with multidetector-row helical computed tomography (MRH-CT) preoperatively, and evaluated its usefulness. Fourteen patients with anorectal malformations before anorectoplasty (types: high n=6, intermediate n=2, low n=6) and two patients without anorectal malformations as controls (total: male n=8, female n=8) were investigated. An image of pelvic region was prepared with a slice thickness of 0.5 mm and a reconstruction pitch of 0.5 mm. A 3D reconstruction on a conventional personal computer (PC) was made with a volume rendering method, and assisted by our own software. The SMC was analyzed with three modified modes of 3D reconstruction corresponding to the surrounding tissues. A length of the parasagittal muscle, and both the sagittal and transverse width of the vertical fibers in the SMC at the connection to the parasagittal muscle were measured on a 3D image and then compared among three different types and controls. To eliminate variations in age, a length index was used to allow comparison. The 3D configuration of the SMC was different in every case. The arranged image mode, which displayed the SMC and the pelvic bones simultaneously, enabled to use conventional knowledge in cysto-urethrography. The length of the parasagittal muscle was longest in the high type but the width of the vertical fibers was smallest. Anatomical figures of the SMC including the external anal sphincter were clearly demonstrated on a PC in every anorectal malformation by our program. A 3D reconstruction image provides positional information on the SMC for the body surface and pelvic bone at the same time

  13. Stature estimation from skull measurements using multidetector computed tomographic images: A Japanese forensic sample.

    PubMed

    Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Yamaguchi, Rutsuko; Hashimoto, Mari; Hoshioka, Yumi; Iwase, Hirotaro

    2016-01-01

    The aim of this study was to assess the correlation between stature and cranial measurements in a contemporary Japanese population, using three-dimensional (3D) computed tomographic (CT) images. A total of 228 cadavers (123 males, 105 females) underwent postmortem CT scanning and subsequent forensic autopsy between May 2011 and April 2015. Five cranial measurements were taken from 3D CT reconstructed images that extracted only cranial data. The correlations between stature and each of the cranial measurements were assessed with Pearson product-moment correlation coefficients. Simple and multiple regression analyses showed significant correlations between stature and cranial measurements. In conclusion, cranial measurements obtained from 3D CT images may be useful for forensic estimation of the stature of Japanese individuals, particularly in cases where better predictors, such as long bones, are not available.

  14. Contribution of diffusion weighted MRI to diagnosis and staging in gastric tumors and comparison with multi-detector computed tomography

    PubMed Central

    Fatih Özbay, Mehmet; Çallı, İskan; Doğan, Erkan; Çelik, Sebahattin; Batur, Abdussamet; Bora, Aydın; Yavuz, Alpaslan; Bulut, Mehmet Deniz; Özgökçe, Mesut; Çetin Kotan, Mehmet

    2017-01-01

    Abstract Background Diagnostic performance of Diffusion-Weighted magnetic resonance Imaging (DWI) and Multi-Detector Computed Tomography (MDCT) for TNM (Tumor, Lymph node, Metastasis) staging of gastric cancer was compared. Patients and methods We used axial T2-weighted images and DWI (b-0,400 and b-800 s/mm2) protocol on 51 pre-operative patients who had been diagnosed with gastric cancer. We also conducted MDCT examinations on them. We looked for a signal increase in the series of DWI images. The depth of tumor invasion in the stomach wall (tumor (T) staging), the involvement of lymph nodes (nodal (N) staging), and the presence or absence of metastases (metastatic staging) in DWI and CT images according to the TNM staging system were evaluated. In each diagnosis of the tumors, sensitivity, specificity, positive and negative accuracy rates of DWI and MDCT examinations were found through a comparison with the results of the surgical pathology, which is the gold standard method. In addition to the compatibilities of each examination with surgical pathology, kappa statistics were used. Results Sensitivity and specificity of DWI and MDCT in lymph node staging were as follows: N1: DWI: 75.0%, 84.6%; MDCT: 66.7%, 82%;N2: DWI: 79.3%, 77.3%; MDCT: 69.0%, 68.2%; N3: DWI: 60.0%, 97.6%; MDCT: 50.0%, 90.2%. The diagnostic tool DWI seemed more compatible with the gold standard method (surgical pathology), especially in the staging of lymph node, when compared to MDCT. On the other hand, in T staging, the results of DWI and MDCT were better than the gold standard when the T stage increased. However, DWI did not demonstrate superiority to MDCT. The sensitivity and specificity of both imaging techniques for detecting distant metastasis were 100%. Conclusions The diagnostic accuracy of DWI for TNM staging in gastric cancer before surgery is at a comparable level with MDCT and adding DWI to routine protocol of evaluating lymph nodes metastasis might increase diagnostic accuracy

  15. Criteria for establishing shielding of multi-detector computed tomography (MDCT) rooms.

    PubMed

    Verdun, F R; Aroua, A; Baechler, S; Schmidt, S; Trueb, P R; Bochud, F O

    2010-01-01

    The aim of this work is to compare two methods used for determining the proper shielding of computed tomography (CT) rooms while considering recent technological advances in CT scanners. The approaches of the German Institute for Standardisation and the US National Council on Radiation Protection and Measurements were compared and a series of radiation measurements were performed in several CT rooms at the Lausanne University Hospital. The following three-step procedure is proposed for assuring sufficient shielding of rooms hosting new CT units with spiral mode acquisition and various X-ray beam collimation widths: (1) calculate the ambient equivalent dose for a representative average weekly dose length product at the position where shielding is required; (2) from the maximum permissible weekly dose at the location of interest, calculate the transmission factor F that must be taken to ensure proper shielding and (3) convert the transmission factor into a thickness of lead shielding. A similar approach could be adopted to use when designing shielding for fluoroscopy rooms, where the basic quantity would be the dose area product instead of the load of current (milliampere-minute).

  16. Stature estimation in a contemporary Japanese population based on clavicular measurements using multidetector computed tomography.

    PubMed

    Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Yamaguchi, Rutsuko; Hashimoto, Mari; Hoshioka, Yumi; Iwase, Hirotaro

    2017-03-08

    The aims of this study was to assess the correlation between stature and clavicular measurements in a contemporary Japanese population using three-dimensional (3D) computed tomographic (CT) images, and to establish regression equations for predicting stature. A total of 249 cadavers (131 males, 118 females) underwent postmortem CT scanning and subsequent forensic autopsy between October 2011 and May 2016 in our department. Four clavicular variables (linear distances between the superior margins of the left and right sternal facets to the anterior points of the left and right acromial ends and between the superior margins of the left and right sternal facets to the left and right conoid tubercles) were measured using 3D CT reconstructed images that extracted only bone data. The correlations between stature and each of the clavicular measurements were assessed with Pearson product-moment correlation coefficients. These clavicular measurements correlated significantly with stature in both sexes. The lowest standard error of estimation value in all, male, and female subjects was 3.62cm (r(2)=0.836), 3.55cm (r(2)=0.566), and 3.43cm (r(2)=0.663), respectively. In conclusion, clavicular measurements obtained from 3D CT images may be useful for stature estimation of Japanese individuals, particularly in cases where better predictors, such as long bones, are not available.

  17. Three-dimensional multidetector computed tomography may aid preoperative planning of the transmanubrial osteomuscular-sparing approach to completely resect superior sulcus tumor.

    PubMed

    Saji, Hisashi; Kato, Yasufumi; Shimada, Yoshihisa; Kudo, Yujin; Hagiwara, Masaru; Matsubayashi, Jun; Nagao, Toshitaka; Ikeda, Norihiko

    2015-11-01

    The anterior transcervical-thoracic approach clearly exposes the subclavian vessels and brachial plexus. We believe that this approach is optimal when a superior sulcus tumor (SST) invades the anterior part of the thoracic inlet. However, this approach is not yet widely applied because anatomical relationships in this procedure are difficult to visualize. Three-dimensional tomography can considerably improve preoperative planning, enhance the surgeon's skill and simplify the approach to complex surgical procedures. We applied preoperative 3-dimensional multidetector computed tomography to a case where an SST had invaded the anterior part of the thoracic inlet including the clavicle, sternoclavicular joint, first rib, subclavian vessels and brachial plexus. After the patient underwent induction chemotherapy, we performed the transmanubrial osteomuscular-sparing approach and added a third anterolateral thoracotomy with a hemi-clamshell incision and completely resected the tumor.

  18. Dataset of calcified plaque condition in the stenotic coronary artery lesion obtained using multidetector computed tomography to indicate the addition of rotational atherectomy during percutaneous coronary intervention.

    PubMed

    Akutsu, Yasushi; Hamazaki, Yuji; Sekimoto, Teruo; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Suyama, Jumpei; Gokan, Takehiko; Sakai, Koshiro; Kosaki, Ryota; Yokota, Hiroyuki; Tsujita, Hiroaki; Tsukamoto, Shigeto; Sakurai, Masayuki; Sambe, Takehiko; Oguchi, Katsuji; Uchida, Naoki; Kobayashi, Shinichi; Aoki, Atsushi; Kobayashi, Youichi

    2016-06-01

    Our data shows the regional coronary artery calcium scores (lesion CAC) on multidetector computed tomography (MDCT) and the cross-section imaging on MDCT angiography (CTA) in the target lesion of the patients with stable angina pectoris who were scheduled for percutaneous coronary intervention (PCI). CAC and CTA data were measured using a 128-slice scanner (Somatom Definition AS+; Siemens Medical Solutions, Forchheim, Germany) before PCI. CAC was measured in a non-contrast-enhanced scan and was quantified using the Calcium Score module of SYNAPSE VINCENT software (Fujifilm Co. Tokyo, Japan) and expressed in Agatston units. CTA were then continued with a contrast-enhanced ECG gating to measure the severity of the calcified plaque condition. We present that both CAC and CTA data are used as a benchmark to consider the addition of rotational atherectomy during PCI to severely calcified plaque lesions.

  19. Dataset of calcified plaque condition in the stenotic coronary artery lesion obtained using multidetector computed tomography to indicate the addition of rotational atherectomy during percutaneous coronary intervention

    PubMed Central

    Akutsu, Yasushi; Hamazaki, Yuji; Sekimoto, Teruo; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Suyama, Jumpei; Gokan, Takehiko; Sakai, Koshiro; Kosaki, Ryota; Yokota, Hiroyuki; Tsujita, Hiroaki; Tsukamoto, Shigeto; Sakurai, Masayuki; Sambe, Takehiko; Oguchi, Katsuji; Uchida, Naoki; Kobayashi, Shinichi; Aoki, Atsushi; Kobayashi, Youichi

    2016-01-01

    Our data shows the regional coronary artery calcium scores (lesion CAC) on multidetector computed tomography (MDCT) and the cross-section imaging on MDCT angiography (CTA) in the target lesion of the patients with stable angina pectoris who were scheduled for percutaneous coronary intervention (PCI). CAC and CTA data were measured using a 128-slice scanner (Somatom Definition AS+; Siemens Medical Solutions, Forchheim, Germany) before PCI. CAC was measured in a non-contrast-enhanced scan and was quantified using the Calcium Score module of SYNAPSE VINCENT software (Fujifilm Co. Tokyo, Japan) and expressed in Agatston units. CTA were then continued with a contrast-enhanced ECG gating to measure the severity of the calcified plaque condition. We present that both CAC and CTA data are used as a benchmark to consider the addition of rotational atherectomy during PCI to severely calcified plaque lesions. PMID:26977441

  20. Surgically Cured, Relapsed Pneumococcal Meningitis Due to Bone Defects, Non-invasively Identified by Three-dimensional Multi-detector Computed Tomography

    PubMed Central

    Akimoto, Takayoshi; Morita, Akihiko; Shiobara, Keiji; Hara, Makoto; Minami, Masayuki; Shijo, Katsunori; Nomura, Yasuyuki; Shigihara, Shuntaro; Haradome, Hiroki; Abe, Osamu; Kamei, Satoshi

    2016-01-01

    A 43-year-old Japanese man presented with a history of bacterial meningitis (BM). He was admitted to our department with a one-day history of headache and was diagnosed with relapse of BM based on the cerebrospinal fluid findings. The conventional imaging studies showed serial findings suggesting left otitis media, a temporal cephalocele, and meningitis. Three-dimensional multi-detector computed tomography (3D-MDCT) showed left petrous bone defects caused by the otitis media, and curative surgical treatment was performed. Skull bone structural abnormalities should be considered a cause of relapsed BM. 3D-MDCT was useful for revealing the causal minimal bone abnormality and performing pre-surgical mapping. PMID:27980270

  1. Usefulness of 40-slice multidetector row computed tomography to detect coronary disease in patients prior to cardiac valve surgery.

    PubMed

    Pouleur, Anne-Catherine; le Polain de Waroux, Jean-Benoît; Kefer, Joëlle; Pasquet, Agnès; Coche, Emmanuel; Vanoverschelde, Jean-Louis; Gerber, Bernhard L

    2007-12-01

    Preoperative identification of significant coronary artery disease (CAD) in patients prior to valve surgery requires systematic invasive coronary angiography. The purpose of this current prospective study was to evaluate whether exclusion of CAD by multi-detector CT (MDCT) might potentially avoid systematic cardiac catheterization in these patients. Eighty-two patients (53 males, 62 +/- 13 years) scheduled to undergo valve surgery underwent 40-slice MDCT before invasive quantitative coronary angiography (QCA). According to QCA, 15 patients had CAD (5 one-vessel, 6 two-vessel and 4 three-vessel disease). The remaining 67 patients had no CAD. On a per-vessel basis, MDCT correctly identified 27/29 (sensitivity 93%) vessels with and excluded 277/299 vessels (specificity 93%) without CAD. On a per-patient basis, MDCT correctly identified 14/15 patients with (sensitivity 93%) and 60/67 patients without CAD (specificity 90%). Positive and negative predictive values of MDCT were 67% and 98%. Performing invasive angiography only in patients with abnormal MDCT might have avoided QCA in 60/82 (73%). MDCT could be potentially useful in the preoperative evaluation of patients with valve disease. By selecting only those patients with coronary lesions to undergo invasive coronary angiography, it could avoid cardiac catheterization in a large number of patients without CAD.

  2. The Role of Multidetector Computed Tomography in the Early Diagnosis of Invasive Pulmonary Aspergillosis in Patients with Febrile Neutropenia Undergoing Hematopoietic Stem Cell Transplantation

    PubMed Central

    Çiledağ, Nazan; Arda, Kemal; Arıbaş, Bilgin Kadri; Tekgündüz, Ali Irfan Emre; Altuntaş, Fevzi

    2012-01-01

    Objective: To evaluate vessel involvement and the role of multidetector computed tomography (MDCT) in the earlydiagnosis of invasive pulmonary aspergillosis (IPA) in patients with febrile neutropenia and antibiotic-resistant feverundergoing autologous bone morrow transplantation. Material and Methods: In all, 74 pulmonary MDCT examinations in 37 consecutive hematopoietic stem celltransplantation patients with febrile neutropenia and clinically suspected IPA were retrospectively evaluated. Results: Diagnosis of IPA was based on Fungal Infections Cooperative Group, and National Institute of Allergy andInfectious Diseases Mycoses Study Consensus Group criteria. In all, 0, 14, and 11 patients were diagnosed as proven,probable, and possible IPA, respectively. Among the 25 patients accepted as probable and possible IPA, all had pulmonaryMDCT findings consistent with IPA. The remaining 12 patients were accepted as having fever of unknown origin (FUO)and had patent vessels based on MDCT findings.In the patients with probable and possible IPA, 72 focal pulmonary lesions were observed; in 41 of the 72 (57%) lesionsvascular occlusion was noted and the CT halo sign was observed in 25 of these 41 (61%) lesions. Resolution of feveroccurred following antifungal therapy in 19 (76%) of the 25 patients with probable and possible IPA. In all, 6 (25%)of the patients diagnosed as IPA died during follow-up. Transplant-related mortality 100 d post transplant in patientswith IPA and FUO was 24% and 0%, respectively. Conclusion: In conclusion, MDCT has a potential role in the early diagnosis of IPA via detection of vessel occlusion. PMID:24744620

  3. Optic Strut and Para-clinoid Region – Assessment by Multi-detector Computed Tomography with Multiplanar and 3 Dimensional Reconstructions

    PubMed Central

    Ravikiran, S.R.; Kumar, Ashvini; Chavadi, Channabasappa; Pulastya, Sanyal

    2015-01-01

    Purpose To evaluate thickness, location and orientation of optic strut and anterior clinoid process and variations in paraclinoid region, solely based on multidetector computed tomography (MDCT) images with multiplanar (MPR) and 3 dimensional (3D) reconstructions, among Indian population. Materials and Methods Ninety five CT scans of head and paranasal sinuses patients were retrospectively evaluated with MPR and 3D reconstructions to assess optic strut thickness, angle and location, variations like pneumatisation, carotico-clinoid foramen and inter-clinoid osseous ridge. Results Mean optic strut thickness was 3.64mm (±0.64), optic strut angle was 42.67 (±6.16) degrees. Mean width and length of anterior clinoid process were 10.65mm (±0.79) and 11.20mm (±0.95) respectively. Optic strut attachment to sphenoid body was predominantly sulcal as in 52 cases (54.74%) and was most frequently attached to anterior 2/5th of anterior clinoid process, seen in 93 sides (48.95%). Pneumatisation of optic strut occurred in 23 sides. Carotico-clinoid foramen was observed in 42 cases (22.11%), complete foramen in 10 cases (5.26%), incomplete foramen in 24 cases (12.63%) and contact type in 8 cases (4.21%). Inter-clinoid osseous bridge was seen unilaterally in 4 cases. Conclusion The study assesses morphometric features and anatomical variations of paraclinoid region using MDCT 3D and multiplanar reconstructions in Indian population. PMID:26557589

  4. Incidence of Venous Thromboembolism Using 64 Channel Multidetector Row Computed Tomography-Indirect Venography and Anti-Coagulation Therapy after Total Knee Arthroplasty in Korea

    PubMed Central

    Park, Kyung-Hyun; Cheon, Sang-Ho; Lee, Ji-Ho

    2012-01-01

    Purpose This study evaluated the incidence of a venous thromboembolism (VTE) after total knee arthroplasty (TKA) using multidetector row computed tomography-indirect venography (MDCT-indirect venography) and assessed the efficacy of anti-coagulation therapy. Materials and Methods We enrolled 118 patients with 126 cases of TKA. The average age of the patients was 68.4 years. We used 64 channel MDCT-indirect venography for the detection of VTE. We treated selectively proximal deep vein thrombosis (DVT) or pulmonary thromboembolism (PTE) cases according to the results of MDCT-indirect venography. We re-evaluated the change in VTE using follow-up MDCT-indirect venography after 3 months. Results We identified VTE in 35.7%. DVT only was identified in 22.2% including 8 cases of proximal DVT and 20 cases of distal DVT. PTE without DVT was identified in 4.8%, and combined DVT and PTE in 8.7%. All patients with PTE were asymptomatic, but 4 DVT patients had signs of leg swelling. After anti-coagulation therapy, 20 patients showed complete resolution in 16 cases, improvement in 3 cases and one case showed a new distal DVT. Conclusions The incidence of VTE after primary TKA was 35.7% in Korea. Furthermore, anti-coagulation therapy for proximal DVT and PTE patients may be a useful method for preventing the occurrence of a fatal PTE. PMID:22570848

  5. SU-F-207-01: Comparison of Beam Characteristics and Organ Dose From Four Commercial Multidetector Computed Tomography Scanners

    SciTech Connect

    Ohno, T; Araki, F

    2015-06-15

    Purpose: To compare dosimetric properties and patient organ doses from four commercial multidetector CT (MDCT) using Monte Carlo (MC) simulation based on the absorbed dose measured using a Farmer chamber and cylindrical water phantoms according to AAPM TG-111. Methods: Four commercial MDCT were modeled using the GMctdospp (IMPS, Germany) based on the EGSnrc user code. The incident photon spectrum and bowtie filter for MC simulations were determined so that calculated values of aluminum half-value layer (Al-HVL) and off-center ratio (OCR) profile in air agreed with measured values. The MC dose was calibrated from absorbed dose measurements using a Farmer chamber and cylindrical water phantoms. The dose distributions of head, chest, and abdominal scan were calculated using patient CT images and mean organ doses were evaluated from dose volume histograms. Results: The HVLs at 120 kVp of Brilliance, LightSpeed, Aquilion, and SOMATOM were 9.1, 7.5, 7.2, and 8.7 mm, respectively. The calculated Al-HVLs agreed with measurements within 0.3%. The calculated and measured OCR profiles agreed within 5%. For adult head scans, mean doses for eye lens from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.7, 38.5, 47.2 and 28.4 mGy, respectively. For chest scans, mean doses for lung from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.1, 26.1, 35.3 and 24.0 mGy, respectively. For adult abdominal scans, the mean doses for liver from Brilliance, LightSpeed, Aquilion, and SOMATOM were 16.5, 21.3, 22.7, and 18.0 mGy, respectively. The absorbed doses increased with decreasing Al-HVL. The organ doses from Aquilion were two greater than those from Brilliance in head scan. Conclusion: MC dose distributions based on absorbed dose measurement in cylindrical water phantom are useful to evaluate individual patient organ doses.

  6. Pulmonary adenocarcinomas presenting as ground-glass opacities on multidetector CT: three-dimensional computer-assisted analysis of growth pattern and doubling time

    PubMed Central

    Borghesi, Andrea; Farina, Davide; Michelini, Silvia; Ferrari, Matteo; Benetti, Diego; Fisogni, Simona; Tironi, Andrea; Maroldi, Roberto

    2016-01-01

    PURPOSE We aimed to evaluate the growth pattern and doubling time (DT) of pulmonary adenocarcinomas exhibiting ground-glass opacities (GGOs) on multidetector computed tomography (CT). METHODS The growth pattern and DT of 22 pulmonary adenocarcinomas exhibiting GGOs were retrospectively analyzed using three-dimensional semiautomatic software. Analysis of each lesion was based on calculations of volume and mass changes and their respective DTs throughout CT follow-up. Three-dimensional segmentation was performed by a single radiologist on each CT scan. The same observer and another radiologist independently repeated the segmentation at the baseline and the last CT scan to determine the variability of the measurements. The relationships among DTs, histopathology, and initial CT features of the lesions were also analyzed. RESULTS Pulmonary adenocarcinomas presenting as GGOs exhibited different growth patterns: some lesions grew rapidly and some grew slowly, whereas others alternated between periods of growth, stability, or shrinkage. A significant increase in volume and mass that exceeded the coefficient of repeatability of interobserver variability was observed in 72.7% and 84.2% of GGOs, respectively. The volume-DTs and mass-DTs were heterogeneous throughout the follow-up CT scan (range, −4293 to 21928 and −3113 to 17020 days, respectively), and their intra- and interobserver variabilities were moderately high. The volume-DTs and mass-DTs were not correlated with the initial CT features of GGOs; however, they were significantly shorter in invasive adenocarcinomas (P = 0.002 and P = 0.001, respectively). CONCLUSION Pulmonary adenocarcinomas exhibiting GGOs show heterogeneous growth patterns with a trend toward a progressive increase in size. DTs may be useful for predicting tumor aggressiveness. PMID:27682741

  7. Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    SciTech Connect

    Fanelli, Fabrizio Bezzi, Mario; Bruni, Antonio; Corona, Mario; Boatta, Emanuele; Lucatelli, Pierleone; Passariello, Roberto

    2011-02-15

    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

  8. Validation of multi-detector computed tomography as a non-invasive method for measuring ovarian volume in macaques (Macaca fascicularis).

    PubMed

    Jones, Jeryl C; Appt, Susan E; Werre, Stephen R; Tan, Joshua C; Kaplan, Jay R

    2010-06-01

    The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non

  9. Magnetic resonance imaging and multi-detector computed tomography assessment of extracellular compartment in ischemic and non-ischemic myocardial pathologies

    PubMed Central

    Saeed, Maythem; Hetts, Steven W; Jablonowski, Robert; Wilson, Mark W

    2014-01-01

    Myocardial pathologies are major causes of morbidity and mortality worldwide. Early detection of loss of cellular integrity and expansion in extracellular volume (ECV) in myocardium is critical to initiate effective treatment. The three compartments in healthy myocardium are: intravascular (approximately 10% of tissue volume), interstitium (approximately 15%) and intracellular (approximately 75%). Myocardial cells, fibroblasts and vascular endothelial/smooth muscle cells represent intracellular compartment and the main proteins in the interstitium are types I/III collagens. Microscopic studies have shown that expansion of ECV is an important feature of diffuse physiologic fibrosis (e.g., aging and obesity) and pathologic fibrosis [heart failure, aortic valve disease, hypertrophic cardiomyopathy, myocarditis, dilated cardiomyopathy, amyloidosis, congenital heart disease, aortic stenosis, restrictive cardiomyopathy (hypereosinophilic and idiopathic types), arrythmogenic right ventricular dysplasia and hypertension]. This review addresses recent advances in measuring of ECV in ischemic and non-ischemic myocardial pathologies. Magnetic resonance imaging (MRI) has the ability to characterize tissue proton relaxation times (T1, T2, and T2*). Proton relaxation times reflect the physical and chemical environments of water protons in myocardium. Delayed contrast enhanced-MRI (DE-MRI) and multi-detector computed tomography (DE-MDCT) demonstrated hyper-enhanced infarct, hypo-enhanced microvascular obstruction zone and moderately enhanced peri-infarct zone, but are limited for visualizing diffuse fibrosis and patchy microinfarct despite the increase in ECV. ECV can be measured on equilibrium contrast enhanced MRI/MDCT and MRI longitudinal relaxation time mapping. Equilibrium contrast enhanced MRI/MDCT and MRI T1 mapping is currently used, but at a lower scale, as an alternative to invasive sub-endomyocardial biopsies to eliminate the need for anesthesia, coronary

  10. Relationship between routine multi-detector cardiac computed tomographic angiography prior to reoperative cardiac surgery, length of stay, and hospital charges.

    PubMed

    Goldstein, Matthew A; Roy, Sion K; Hebsur, Shinivas; Maluenda, Gabriel; Weissman, Gaby; Weigold, Guy; Landsman, Marc J; Hill, Peter C; Pita, Francisco; Corso, Paul J; Boyce, Steven W; Pichard, Augusto D; Waksman, Ron; Taylor, Allen J

    2013-03-01

    While multi-detector cardiac computed tomography angiography (MDCCTA) prior to reoperative cardiac surgery (RCS) has been associated with improved clinical outcomes, its impact on hospital charges and length of stay remains unclear. We studied 364 patients undergoing RCS at Washington Hospital Center between 2004 and 2008, including 137 clinically referred for MDCCTA. Baseline demographics, procedural data, and perioperative outcomes were recorded at the time of the procedure. The primary clinical endpoint was the composite of perioperative death, myocardial infarction (MI), stroke, and hemorrhage-related reoperation. Secondary clinical endpoints included surgical procedural variables and the perioperative volume of bleeding and transfusion. Length of stay was determined using the hospital's electronic medical record. Cost data were extracted from the hospital's billing summary. Analysis was performed on individual categories of care, as well as on total hospital charges. Data were compared between subjects with and without MDCCTA, after adjustment for the Society of Thoracic Surgeons score. Baseline characteristics were similar between the two groups. MDCCTA was associated with shorter procedural times, shorter intensive care unit stays, fewer blood transfusions, and less frequent perioperative MI. There was additionally a trend towards a lower incidence of the primary endpoint (17.5 vs. 24.2 %, p = 0.13) primarily due to a lower incidence of perioperative MI (0 vs. 5.7 %, p = 0.002). MDCCTA was also associated with lower median recovery room [$1,325 (1,250-3,302) vs. $3,217 (1,325-5,353) p < 0.001] and nursing charges [$6,335 (3,623-10,478) vs. $6,916 (3,915-14,499) p = 0.03], although operating room charges were higher [$24,100 (22,300-29,700) vs. $23,500 (19,900-27,700) p < 0.05]. Median total charges [$127,000 (95,000-188,000) vs. $123,000 (86,800-226,000) p = 0.77] and length of stay [9 days (6-19) vs. 11 days (7-19), p = 0.21] were similar. Means analysis

  11. Multidetector computed tomography (MDCT) evaluation of myocardial viability: intraindividual comparison of monomeric vs. dimeric contrast media in a rabbit model.

    PubMed

    Mahnken, Andreas H; Jost, Gregor; Bruners, Philipp; Sieber, Martin; Seidensticker, Peter R; Günther, Rolf W; Pietsch, Hubertus

    2009-02-01

    To evaluate the influence of different types of iodinated contrast media on the assessment of myocardial viability, acute myocardial infarction (MI) was surgically induced in six rabbits. Over a period of 45 min, contrast-enhanced cardiac MDCT (64 x 0.6 mm, 80 kV, 680 mAs(eff.)) was repeatedly performed using a contrast medium dose of 600 mg iodine/kg body weight. Animals received randomized iopromide 300 and iodixanol 320, respectively. Attenuation values of healthy and infarcted myocardium were measured. The size of MI was computed and compared with nitroblue tetrazolium (NBT)-stained specimen. The highest attenuation differences between infarcted and healthy myocardium occurred during the arterial phase with 140.0+/-3.5 HU and 141.0+/-2.2 HU for iopromide and iodixanol, respectively. For iodixanol the highest attenuation difference on delayed contrast-enhanced images was achieved 3 min post injection (73.5 HU). A slightly higher attenuation difference was observed for iopromide 6 min after contrast medium injection (82.2 HU), although not statistically significant (p=0.6437). Mean infarct volume as measured by NBT staining was 33.5%+/-13.6%. There was an excellent agreement of infarct sizes among NBT-, iopromide- and iodixanol-enhanced MDCT with concordance-correlation coefficients ranging from rho(c)=0.9928-0.9982. Iopromide and iodixanol both allow a reliable assessment of MI with delayed contrast-enhanced MDCT.

  12. Anatomy of the larynx and pharynx: effects of age, gender and height revealed by multidetector computed tomography.

    PubMed

    Inamoto, Y; Saitoh, E; Okada, S; Kagaya, H; Shibata, S; Baba, M; Onogi, K; Hashimoto, S; Katada, K; Wattanapan, P; Palmer, J B

    2015-09-01

    Although oropharyngeal and laryngeal structures are essential for swallowing, the three-dimensional (3D) anatomy is not well understood, due in part to limitations of available measuring techniques. This study uses 3D images acquired by 320-row area detector computed tomography ('320-ADCT'), to measure the pharynx and larynx and to investigate the effects of age, gender and height. Fifty-four healthy volunteers (30 male, 24 female, 23-77 years) underwent one single-phase volume scan (0.35 s) with 320-ADCT during resting tidal breathing. Six measurements of the pharynx and two of larynx were performed. Bivariate statistical methods were used to analyse the effects of gender, age and height on these measurements. Length and volume were significantly larger for men than for women for every measurement (P < 0.05) and increased with height (P < 0.05). Multiple regression analysis was performed to understand the interactions of gender, height and age. Gender, height and age each had significant effects on certain values. The volume of the larynx and hypopharynx was significantly affected by height and age. The length of pharynx was associated with gender and age. Length of the vocal folds and distance from the valleculae to the vocal folds were significantly affected by gender (P < 0.05). These results suggest that age, gender and height have independent and interacting effects on the morphology of the pharynx and larynx. Three-dimensional imaging and morphometrics using 320-ADCT are powerful tools for efficiently and reliably observing and measuring the pharynx and larynx.

  13. Role of multidetector computed tomography in the diagnosis and management of patients attending the rapid access chest pain clinic, The Scottish computed tomography of the heart (SCOT-HEART) trial: study protocol for randomized controlled trial

    PubMed Central

    2012-01-01

    Background Rapid access chest pain clinics have facilitated the early diagnosis and treatment of patients with coronary heart disease and angina. Despite this important service provision, coronary heart disease continues to be under-diagnosed and many patients are left untreated and at risk. Recent advances in imaging technology have now led to the widespread use of noninvasive computed tomography, which can be used to measure coronary artery calcium scores and perform coronary angiography in one examination. However, this technology has not been robustly evaluated in its application to the clinic. Methods/design The SCOT-HEART study is an open parallel group prospective multicentre randomized controlled trial of 4,138 patients attending the rapid access chest pain clinic for evaluation of suspected cardiac chest pain. Following clinical consultation, participants will be approached and randomized 1:1 to receive standard care or standard care plus ≥64-multidetector computed tomography coronary angiography and coronary calcium score. Randomization will be conducted using a web-based system to ensure allocation concealment and will incorporate minimization. The primary endpoint of the study will be the proportion of patients diagnosed with angina pectoris secondary to coronary heart disease at 6 weeks. Secondary endpoints will include the assessment of subsequent symptoms, diagnosis, investigation and treatment. In addition, long-term health outcomes, safety endpoints, such as radiation dose, and health economic endpoints will be assessed. Assuming a clinic rate of 27.0% for the diagnosis of angina pectoris due to coronary heart disease, we will need to recruit 2,069 patients per group to detect an absolute increase of 4.0% in the rate of diagnosis at 80% power and a two-sided P value of 0.05. The SCOT-HEART study is currently recruiting participants and expects to report in 2014. Discussion This is the first study to look at the implementation of computed

  14. Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: comparison with cine magnetic resonance imaging.

    PubMed

    Belge, Bénédicte; Coche, Emmanuel; Pasquet, Agnès; Vanoverschelde, Jean-Louis J; Gerber, Bernhard L

    2006-07-01

    Retrospective reconstruction of ECG-gated images at different parts of the cardiac cycle allows the assessment of cardiac function by multi-detector row CT (MDCT) at the time of non-invasive coronary imaging. We compared the accuracy of such measurements by MDCT to cine magnetic resonance (MR). Forty patients underwent the assessment of global and regional cardiac function by 16-slice MDCT and cine MR. Left ventricular (LV) end-diastolic and end-systolic volumes estimated by MDCT (134+/-51 and 67+/-56 ml) were similar to those by MR (137+/-57 and 70+/-60 ml, respectively; both P=NS) and strongly correlated (r=0.92 and r=0.95, respectively; both P<0.001). Consequently, LV ejection fractions by MDCT and MR were also similar (55+/-21 vs. 56+/-21%; P=NS) and highly correlated (r=0.95; P<0.001). Regional end-diastolic and end-systolic wall thicknesses by MDCT were highly correlated (r=0.84 and r=0.92, respectively; both P<0.001), but significantly lower than by MR (8.3+/-1.8 vs. 8.8+/-1.9 mm and 12.7+/-3.4 vs. 13.3+/-3.5 mm, respectively; both P<0.001). Values of regional wall thickening by MDCT and MR were similar (54+/-30 vs. 51+/-31%; P=NS) and also correlated well (r=0.91; P<0.001). Retrospectively gated MDCT can accurately estimate LV volumes, EF and regional LV wall thickening compared to cine MR.

  15. Scenes from the past: initial investigation of early jurassic vertebrate fossils with multidetector CT.

    PubMed

    Bolliger, Stephan A; Ross, Steffen; Thali, Michael J; Hostettler, Bernhard; Menkveld-Gfeller, Ursula

    2012-01-01

    The study of fossils permits the reconstruction of past life on our planet and enhances our understanding of evolutionary processes. However, many fossils are difficult to recognize, being encased in a lithified matrix whose tedious removal is required before examination is possible. The authors describe the use of multidetector computed tomography (CT) in locating, identifying, and examining fossil remains of crocodilians (Mesosuchia) embedded in hard shale, all without removing the matrix. In addition, they describe how three-dimensional (3D) reformatted CT images provided details that were helpful for extraction and preparation. Multidetector CT can help experienced paleontologists localize and characterize fossils in the matrix of a promising rock specimen in a nondestructive manner. Moreover, with its capacity to generate highly accurate 3D images, multidetector CT can help determine whether the fossils warrant extraction and can assist in planning the extraction process. Thus, multidetector CT may well become an invaluable tool in the field of paleoradiology.

  16. User's manual for rocket combustor interactive design (ROCCID) and analysis computer program. Volume 2: Appendixes A-K

    NASA Technical Reports Server (NTRS)

    Muss, J. A.; Nguyen, T. V.; Johnson, C. W.

    1991-01-01

    The appendices A-K to the user's manual for the rocket combustor interactive design (ROCCID) computer program are presented. This includes installation instructions, flow charts, subroutine model documentation, and sample output files. The ROCCID program, written in Fortran 77, provides a standardized methodology using state of the art codes and procedures for the analysis of a liquid rocket engine combustor's steady state combustion performance and combustion stability. The ROCCID is currently capable of analyzing mixed element injector patterns containing impinging like doublet or unlike triplet, showerhead, shear coaxial and swirl coaxial elements as long as only one element type exists in each injector core, baffle, or barrier zone. Real propellant properties of oxygen, hydrogen, methane, propane, and RP-1 are included in ROCCID. The properties of other propellants can be easily added. The analysis models in ROCCID can account for the influences of acoustic cavities, helmholtz resonators, and radial thrust chamber baffles on combustion stability. ROCCID also contains the logic to interactively create a combustor design which meets input performance and stability goals. A preliminary design results from the application of historical correlations to the input design requirements. The steady state performance and combustion stability of this design is evaluated using the analysis models, and ROCCID guides the user as to the design changes required to satisfy the user's performance and stability goals, including the design of stability aids. Output from ROCCID includes a formatted input file for the standardized JANNAF engine performance prediction procedure.

  17. Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography

    NASA Astrophysics Data System (ADS)

    Park, Hyong-Hu; Goo, Eun-Hoe; Im, In-Chul; Lee, Jae-Seung; Kim, Moon-Jib; Kwak, Byung-Joon; Chung, Woon-Kwan; Dong, Kyung-Rae

    2012-12-01

    The safety of gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid (Gd-EOB-DTPA) has been confirmed, but more study is needed to assess the diagnostic accuracy of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in patients with a hepatocellular carcinoma (HCC) for whom surgical treatment is considered or with a metastatic hepatoma. Research is also needed to examine the rate of detection of hepatic lesions compared to multi-detector computed tomography (MDCT), which is used most frequently to localize and characterize a HCC. Gd-EOB-DTPA-enhanced MRI and iodine-enhanced MDCT imaging were compared for the preoperative detection of focal liver lesions. The clinical usefulness of each method was examined. The current study enrolled 79 patients with focal liver lesions who preoperatively underwent MRI and MDCT. In these patients, there was less than one month between the two diagnostic modalities. Imaging data were taken before and after contrast enhancement in both methods. To evaluate the images, we analyzed the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) in the lesions and the liver parenchyma. To compare the sensitivity of the two methods, we performed a quantitative analysis of the percentage signal intensity of the liver (PSIL) on a high resolution picture archiving and communication system (PACS) monitor (paired-samples t-test, p < 0.05). The enhancement was evaluated based on a consensus of four observers. The enhancement pattern and the morphological features during the arterial and the delayed phases were correlated between the Gd-EOB-DTPA-enhanced MRI findings and the iodine-enhanced MDCT by using an adjusted x2 test. The SNRs, CNRs, and PSIL all had a greater detection rate in Gd-EOB-DTPA enhanced MRI than in iodine-enhanced MDCT. Hepatocyte-selective uptake was observed 20 minutes after the injection in the focal nodular hyperplasia (FNH, 9/9), adenoma (9/10), and highly-differentiated HCC (grade G1, 27/30). Rim

  18. A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution: A cardiac phantom study

    SciTech Connect

    Greuter, M. J. W.; Groen, J. M.; Nicolai, L. J.; Dijkstra, H.; Oudkerk, M.

    2009-11-15

    Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative method which corrects for the influences of these parameters using a linear moving cardiac phantom. Methods: On a robotic arm with artificial arteries with four calcifications of increasing density, a linear movement was applied between 0 and 120 mm/s (step of 10 mm/s). The phantom was scanned five times on 64-slice MDCT, DSCT, and EBT using a standard acquisition protocol. The average Agatston, volume, and mass scores were determined for each velocity, calcification, and scanner. Susceptibility to motion was quantified using a cardiac motion susceptibility (CMS) index. Resemblance to EBT and physical volume and mass was quantified using a {Delta} index. Results: Increasing motion artifacts were observed at increasing velocities on all scanners, with increasing severity from EBT to DSCT to 64-slice MDCT. The calcium score showed a linear dependency on motion from which a correction factor could be derived. This correction factor showed a linear dependency on the mean calcification density with a good fit for all three scoring methods and all three scanners (0.73{<=}R{sup 2}{<=}0.95). The slope and offset of this correction factor showed a linear dependency on temporal resolution with a good fit for all three scoring methods and all three scanners (0.83{<=}R{sup 2}{<=}0.98). CMS was minimal for EBT and increasing values were observed for DSCT and highest values for 64-slice MDCT. CMS was minimal for mass score and increasing values were observed for volume score and highest values for Agatston score. For all densities and scoring methods DSCT showed on average the closest resemblance to EBT calcium scores. When using the correction factor, CMS index decreased on average by

  19. INCIDENTAL AND NONINCIDENTAL CANINE THYROID TUMORS ASSESSED BY MULTIDETECTOR ROW COMPUTED TOMOGRAPHY: A SINGLE-CENTRE CROSS SECTIONAL STUDY IN 4520 DOGS.

    PubMed

    Bertolini, Giovanna; Drigo, Michele; Angeloni, Luca; Caldin, Marco

    2017-02-09

    Thyroid nodules are common in dogs and are increasingly likely to be detected with the increased use of advanced imaging modalities. An unsuspected, nonpalpable, asymptomatic lesion, defined as a thyroid incidentaloma, may be discovered on an imaging study unrelated to the thyroid gland. The objective of this single-center cross-sectional study was to assess the prevalence and computed tomography (CT) characteristics of incidental and nonincidental thyroid tumors in a large population of dogs, using prospective recruitment of patients undergoing CT examination for various reasons during the period of 2005-2015. Unilateral or bilateral thyroid masses were detected in 96/4520 dogs (prevalence, 2.12%; 95% confidence interval [CI], 1.70-2.54%). Seventy-nine (82.3%) lesions were malignant and 17 (17.7%) were benign. Masses were discovered incidentally in 34/96 dogs (overall prevalence of incidentaloma, 0.76%; 95% CI, 0.51-1.02), and 24 (70.6%) of these 34 masses were thyroid carcinomas. Among the CT variables assessed, mineralization, vascular invasion, and tissue invasion were detected only in malignant tumors. Intratumoral vascularization was significantly associated with the presence of thyroid malignancy (P < 0.001). Although incidental thyroid nodules in dogs are relatively rare, they are often malignant. Findings indicated that the neck should be thoroughly assessed in middle-aged and old patients undergoing body CT for various reasons. Thyroid nodules detected incidentally on CT should be sampled to avoid missing thyroid cancer.

  20. Diversity and Determinants of the Three-dimensional Anatomical Axis of the Heart as Revealed Using Multidetector-row Computed Tomography.

    PubMed

    Mori, Shumpei; Anderson, Robert H; Tahara, Natsuko; Izawa, Yu; Toba, Takayoshi; Fujiwara, Sei; Shimoyama, Shinsuke; Watanabe, Yoshiaki; Nishii, Tatsuya; Kono, Atsushi K; Hirata, Ken-Ichi

    2017-02-08

    The location of the heart within the thorax varies significantly between individuals. The resultant diversity of the anatomical cardiac long axis, however, and its determinants, have yet to be systematically investigated. We enrolled 100 consecutive patients undergoing coronary arterial computed tomographic angiography, decomposing the vector of the anatomical cardiac long axis by projecting it to horizontal, frontal, and sagittal planes. The projected vectors on each plane were then converted into three rotation angles using coordinate transformation. We then measured the extent of aortic wedging, using the vertical distance between the inferior margins of the non-adjacent aortic sinus and the epicardium. We took the aortic root rotation angle to be zero when an "en face" view of the right coronary aortic sinus was obtained in the frontal view, defining leftward rotation to be positive. The mean horizontal, frontal, and sagittal rotation angles were 48.7° ± 9.5°, 52.3° ± 12.0°, and 34.0° ± 11.2°, respectively. The mean extent of aortic wedging, and the aortic root rotation angle, were 42.7 ± 9.8 mm, and 5.3° ± 16.4°. Horizontal rotation of the anatomical axis was associated with leftward and ventral rotation, and vice versa. Multivariate analysis showed aortic root rotation to be associated with horizontal cardiac rotation, while aortic wedging is associated with frontal and sagittal cardiac rotation. We have quantified the marked individual variation observed in the anatomical axis of the living heart, identifying the different mechanisms involved in producing the marked three-dimensional diversity of the living heart. Anat Rec, 2017. © 2017 Wiley Periodicals, Inc.

  1. MULTIDETECTOR COMPUTED TOMOGRAPHIC AND LOW-FIELD MAGNETIC RESONANCE IMAGING ANATOMY OF THE QUADRIGEMINAL CISTERN AND CHARACTERIZATION OF SUPRACOLLICULAR FLUID ACCUMULATIONS IN DOGS.

    PubMed

    Bertolini, G; Ricciardi, M; Caldin, M

    2016-05-01

    Focal fluid accumulations in the supracollicular region are commonly termed quadrigeminal cysts and may be either subclinical or associated with neurologic deficits in dogs. Little published information is available on normal imaging anatomy and anatomic relationships for the canine quadrigeminal cistern. Objectives of this observational, cross-sectional study were to describe normal quadrigeminal cistern anatomy and determine the prevalence and characteristics of supracollicular fluid accumulations in dogs. Normal descriptions were accomplished using computed tomographic (CT) cisternography in one canine cadaver, and CT and magnetic resonance imaging (MRI) studies of the brain in four prospectively recruited dogs with no evidence of intracranial disease. Prevalence and characteristics descriptions were accomplished using a retrospective review of brain CT or MRI studies performed during the period of 2005-2015. The normal quadrigeminal cistern consistently exhibited a complex H shape and was separated from the third ventricle by a thin membrane. Prevalence of supracollicular fluid accumulations (SFAs) was 2.19% among CT studies (n = 4427) and 2.2% among MRI studies (n = 626). Dogs with SFA were significantly younger than control dogs (P < 0.0001). Shih-tzu (OR = 111.6), Chihuahua (OR = 81.1), and Maltese (OR = 27.6) breed dogs were predisposed (P < 0.0001). Among dogs with SFAs, the following three patterns were defined: (1) third ventricle (49.54%), (2) quadrigeminal cistern (13.51%), and (3) both third ventricle and quadrigeminal cistern (36.93%). Authors recommend that the term supracollicular fluid accumulation (SFA) should be used rather than the term quadrigeminal cyst to describe these focal fluid accumulations in dogs.

  2. Multidetector CT of emergent biliary pathologic conditions.

    PubMed

    Patel, Neel B; Oto, Aytekin; Thomas, Stephen

    2013-01-01

    Various biliary pathologic conditions can lead to acute abdominal pain. Specific diagnosis is not always possible clinically because many biliary diseases have overlapping signs and symptoms. Imaging can help narrow the differential diagnosis and lead to a specific diagnosis. Although ultrasonography (US) is the most useful imaging modality for initial evaluation of the biliary system, multidetector computed tomography (CT) is helpful when US findings are equivocal or when biliary disease is suspected. Diagnostic accuracy can be increased by optimizing the CT protocol and using multiplanar reformations to localize biliary obstruction. CT can be used to diagnose and stage acute cholecystitis, including complications such as emphysematous, gangrenous, and hemorrhagic cholecystitis; gallbladder perforation; gallstone pancreatitis; gallstone ileus; and Mirizzi syndrome. CT also can be used to evaluate acute biliary diseases such as biliary stone disease, benign and malignant biliary obstruction, acute cholangitis, pyogenic hepatic abscess, hemobilia, and biliary necrosis and iatrogenic complications such as biliary leaks and malfunctioning biliary drains and stents. Treatment includes radiologic, endoscopic, or surgical intervention. Familiarity with CT imaging appearances of emergent biliary pathologic conditions is important for prompt diagnosis and appropriate clinical referral and treatment.

  3. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    MedlinePlus

    ... Graft (CABG) Surgery Atherosclerosis Coronary Artery Disease (CAD) Heart Attack • Home • About Heart Attacks • Warning Signs of a ... Heart Attack • Heart Attack Tools & Resources • Support Network Heart Attack Tools & Resources What Is a Heart Attack? How ...

  4. CHIMERA Multidetector at Laboratori Nazionali del Sud

    SciTech Connect

    Aiello, S.; Anzalone, A.; Baldo, M.; Barna, R.; Campisi, M.g.; Cardella, G.; Cavallaro, Sl., Amico, V.D.; De Filippo, E.; DePasquale, D.; Femino, S.; Geraci, E.; Giustolisi, F.; Guazzoni, P.; Iacono-Manno, C.M.; Italiano, A.; Lanzalone, G.; Lanzano, G.; LoNigro, S.; Lombardo, U.; Manfredi, G.; Pagano, A.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Sambataro, S.; Sperduto, M.L.; Sutera, C.M.; Zetta, L.

    2000-12-31

    The installation of CHIMERA multidetector, designed in order to study central collisions in heavy ion reactions at intermediate energy, is going on at LNS and the first experiment with the forward part (688 telescopes) is running since May 1999. The aim of this contribution is to present the status of the project.

  5. Penetrating wounds to the torso: evaluation with triple-contrast multidetector CT.

    PubMed

    Lozano, J Diego; Munera, Felipe; Anderson, Stephan W; Soto, Jorge A; Menias, Christine O; Caban, Kim M

    2013-01-01

    Penetrating injuries account for a large percentage of visits to emergency departments and trauma centers worldwide. Emergency laparotomy is the accepted standard of care in patients with a penetrating torso injury who are not hemodynamically stable and have a clinical indication for exploratory laparotomy, such as evisceration or gastrointestinal bleeding. Continuous advances in technology have made computed tomography (CT) an indispensable tool in the evaluation of many patients who are hemodynamically stable, have no clinical indication for exploratory laparotomy, and are candidates for conservative treatment. Multidetector CT may depict the trajectory of a penetrating injury and help determine what type of intervention is necessary on the basis of findings such as active arterial extravasation and major vascular, hollow viscus, or diaphragmatic injuries. Because multidetector CT plays an increasing role in the evaluation of patients with penetrating wounds to the torso, the radiologists who interpret these studies should be familiar with the CT findings that mandate intervention.

  6. Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.

    PubMed

    Holly, Brian P; Steenburg, Scott D

    2011-01-01

    Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.

  7. Multidetector CT and postprocessing in planning and assisting in minimally invasive bronchoscopic airway interventions.

    PubMed

    Nair, Arjun; Godoy, Myrna C; Holden, Emma L; Madden, Brendan P; Chua, Felix; Ost, David E; Roos, Justus E; Naidich, David P; Vlahos, Ioannis

    2012-01-01

    A widening spectrum of increasingly advanced bronchoscopic techniques is available for the diagnosis and treatment of various bronchopulmonary diseases. The evolution of computed tomography (CT)-multidetector CT in particular-has paralleled these advances. The resulting development of two-dimensional and three-dimensional (3D) postprocessing techniques has complemented axial CT interpretation in providing more anatomically familiar information to the pulmonologist. Two-dimensional techniques such as multiplanar recontructions and 3D techniques such as virtual bronchoscopy can provide accurate guidance for increasing yield in transbronchial needle aspiration and transbronchial biopsy of mediastinal and hilar lymph nodes. Sampling of lesions located deeper within the lung periphery via bronchoscopic pathways determined at virtual bronchoscopy are also increasingly feasible. CT fluoroscopy for real-time image-guided sampling is now widely available; electromagnetic navigation guidance is being used in select centers but is currently more costly. Minimally invasive bronchoscopic techniques for restoring airway patency in obstruction caused by both benign and malignant conditions include mechanical strategies such as airway stent insertion and ablative techniques such as electrocauterization and cryotherapy. Multidetector CT postprocessing techniques provide valuable information for planning and surveillance of these treatment methods. In particular, they optimize the evaluation of dynamic obstructive conditions such as tracheobronchomalacia, especially with the greater craniocaudal coverage now provided by wide-area detectors. Multidetector CT also provides planning information for bronchoscopic treatment of bronchopleural fistulas and bronchoscopic lung volume reduction for carefully selected patients with refractory emphysema.

  8. Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

    PubMed

    Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G

    2006-01-01

    In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution.

  9. Lymphoepithelial cyst of the pancreas--evaluation with multidetector CT.

    PubMed

    Neyman, Edward G; Georgiades, Christos S; Horton, Karen H; Lillemoe, Keith D; Fishman, Elliot K

    2005-01-01

    Lymphoepithelial cyst of the pancreas is a rare cystic pancreatic tumor. In this case report we provide the imaging perspective of the lesion including the role of multidetector CT (MDCT) and CT angiography and 3D imaging.

  10. Multidetector CT of Surgically Proven Blunt Bowel and Mesenteric Injury.

    PubMed

    Bates, David D B; Wasserman, Michael; Malek, Anita; Gorantla, Varun; Anderson, Stephan W; Soto, Jorge A; LeBedis, Christina A

    2017-01-01

    Blunt traumatic injury is one of the leading causes of morbidity and mortality in the United States. Unintentional injury represents the leading cause of death in the United States for all persons between the ages of 1 and 44 years. In the setting of blunt abdominal trauma, the reported rate of occurrence of bowel and mesenteric injuries ranges from 1% to 5%. Despite the relatively low rate of blunt bowel and mesenteric injury in patients with abdominal and pelvic trauma, delays in diagnosis are associated with increased rates of sepsis, a prolonged course in the intensive care unit, and increased mortality. During the past 2 decades, as multidetector computed tomography (CT) has emerged as an essential tool in emergency radiology, several direct and indirect imaging features have been identified that are associated with blunt bowel and mesenteric injury. The imaging findings in cases of blunt bowel and mesenteric injury can be subtle and may be seen in the setting of multiple complex injuries, such as multiple solid-organ injuries and spinal fractures. Familiarity with the various imaging features of blunt bowel and mesenteric injury, as well as an understanding of their clinical importance with regard to the care of the patient, is essential to making a timely diagnosis. Once radiologists are familiar with the spectrum of findings of blunt bowel and mesenteric injury, they will be able to make timely diagnoses that will lead to improved patient outcomes. (©)RSNA, 2017.

  11. Multidetector CT angiography for acute gastrointestinal bleeding: technique and findings.

    PubMed

    Artigas, José M; Martí, Milagros; Soto, Jorge A; Esteban, Helena; Pinilla, Inmaculada; Guillén, Eugenia

    2013-01-01

    Acute gastrointestinal bleeding is a common reason for emergency department admissions and an important cause of morbidity and mortality. Factors that complicate its clinical management include patient debility due to comorbidities; intermittence of hemorrhage; and multiple sites of simultaneous bleeding. Its management, therefore, must be multidisciplinary and include emergency physicians, gastroenterologists, and surgeons, as well as radiologists for diagnostic imaging and interventional therapy. Upper gastrointestinal tract bleeding is usually managed endoscopically, with radiologic intervention reserved as an alternative to be used if endoscopic therapy fails. Endoscopy is often less successful in the management of acute lower gastrointestinal tract bleeding, where colonoscopy may be more effective. The merits of performing bowel cleansing before colonoscopy in such cases might be offset by the resultant increase in response time and should be weighed carefully against the deficits in visualization and diagnostic accuracy that would result from performing colonoscopy without bowel preparation. In recent years, multidetector computed tomographic (CT) angiography has gained acceptance as a first-line option for the diagnosis and management of lower gastrointestinal tract bleeding. In selected cases of upper gastrointestinal tract bleeding, CT angiography also provides accurate information about the presence or absence of active bleeding, its source, and its cause. This information helps shorten the total diagnostic time and minimizes or eliminates the need for more expensive and more invasive procedures.

  12. Search for continuous gravitational waves: Metric of the multidetector F-statistic

    SciTech Connect

    Prix, Reinhard

    2007-01-15

    We develop a general formalism for the parameter-space metric of the multidetector F-statistic, which is a matched-filtering detection statistic for continuous gravitational waves. We find that there exists a whole family of F-statistic metrics, parametrized by the (unknown) amplitude parameters of the gravitational wave. The multidetector metric is shown to be expressible in terms of noise-weighted averages of single-detector contributions, which implies that the number of templates required to cover the parameter space does not scale with the number of detectors. Contrary to using a longer observation time, combining detectors of similar sensitivity is therefore the computationally cheapest way to improve the sensitivity of coherent wide-parameter searches for continuous gravitational waves. We explicitly compute the F-statistic metric family for signals from isolated spinning neutron stars, and we numerically evaluate the quality of different metric approximations in a Monte Carlo study. The metric predictions are tested against the measured mismatches and we identify regimes in which the local metric is no longer a good description of the parameter-space structure.

  13. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    SciTech Connect

    Wang, Xiaohua; Yuan, Huishu; Duan, Jianghui; Du, Yipeng; Shen, Ning; He, Bei

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  14. Three-dimensional imaging in the context of minimally invasive and transcatheter cardiovascular interventions using multi-detector computed tomography: from pre-operative planning to intra-operative guidance.

    PubMed

    Schoenhagen, Paul; Numburi, Uma; Halliburton, Sandra S; Aulbach, Peter; von Roden, Martin; Desai, Milind Y; Rodriguez, Leonardo L; Kapadia, Samir R; Tuzcu, E Murat; Lytle, Bruce W

    2010-11-01

    The rapid expansion of less invasive surgical and transcatheter cardiovascular procedures for a wide range of cardiovascular conditions, including coronary, valvular, structural cardiac, and aortic disease has been paralleled by novel three-dimensional (3-D) approaches to imaging. Three-dimensional imaging allows acquisition of volumetric data sets and subsequent off-line reconstructions along unlimited 2-D planes and 3-D volumes. Pre-procedural 3-D imaging provides detailed understanding of the operative field for surgical/interventional planning. Integration of imaging modalities during the procedure allows real-time guidance. Because computed tomography routinely acquires 3-D data sets, it has been one of the early imaging modalities applied in the context of surgical and interventional planning. This review describes the continuum of applications from pre-operative planning to procedural integration, based on the emerging experience with computed tomography and rotational angiography, respectively. At the same time, the potential adverse effects of imaging with X-ray-based tomographic or angiographic modalities are discussed. It is emphasized that the role of imaging guidance in this context remains unclear and will need to be evaluated in clinical trials. This is in particular true, because data showing improved outcome or even non-inferiority for most of the emerging transcatheter procedures are still lacking.

  15. A Modular and Compact Multidetector System Based on Monolithic Telescopes

    SciTech Connect

    Figuera, P.; Cardella, G.; Di Pietro, A.; Papa, M.; Tian, W.; Amorini, F.; Musumarra, A.; Pappalardo, G.; Rizzo, F.; Tudisco, S.; Fallica, G.; Valvo, G.

    2004-02-27

    The characteristics of a new multidetector based on the use of Monolithic Silicon Telescopes are presented. Using suitable ion implantation techniques, the {delta}E and residual energy stages of the telescopes have been integrated on a single Si chip, obtaining a typical thickness for the {delta}E stage of the order of 2{mu}m.

  16. Dedicated multi-detector CT of the esophagus: spectrum of diseases.

    PubMed

    Ba-Ssalamah, Ahmed; Zacherl, Johannes; Noebauer-Huhmann, Iris Melanie; Uffmann, Martin; Matzek, Wolfgang Karl; Pinker, Katja; Herold, Christian; Schima, Wolfgang

    2009-01-01

    Multi-detector computed tomography (CT) offers new opportunities in the imaging of the gastrointestinal tract. Its ability to cover a large volume in a very short scan time, and in a single breath hold with thin collimation and isotropic voxels, allows the imaging of the entire esophagus with high-quality multiplanar reformation and 3D reconstruction. Proper distention of the esophagus and stomach (by oral administration of effervescent granules and water) and optimally timed administration of intravenous contrast material are required to detect and characterize disease. In contrast to endoscopy and double-contrast studies of the upper GI tract, CT provides information about both the esophageal wall and the extramural extent of disease. Preoperative staging of esophageal carcinoma appears to be the main indication for MDCT. In addition, MDCT allows detection of other esophageal malignancies, such as lymphoma and benign esophageal tumors, such as leiomyma. A diagnosis of rupture or fistula of the esophagus can be firmly established using MDCT. Furthermore, miscellaneous esophageal conditions, such as achalasia, esophagitis, diverticula, and varices, are incidental findings and can also be visualized with hydro-multi-detector CT. Multi-detector CT is a valuable tool for the evaluation of esophageal wall disease and serves as an adjunct to endoscopy.

  17. Value and Accuracy of Multidetector Computed Tomography in Obstructive Jaundice

    PubMed Central

    Mathew, Rishi Philip; Moorkath, Abdunnisar; Basti, Ram Shenoy; Suresh, Hadihally B.

    2016-01-01

    Summary Background Objective; To find out the role of MDCT in the evaluation of obstructive jaundice with respect to the cause and level of the obstruction, and its accuracy. To identify the advantages of MDCT with respect to other imaging modalities. To correlate MDCT findings with histopathology/surgical findings/Endoscopic Retrograde CholangioPancreatography (ERCP) findings as applicable. Material/Methods This was a prospective study conducted over a period of one year from August 2014 to August 2015. Data were collected from 50 patients with clinically suspected obstructive jaundice. CT findings were correlated with histopathology/surgical findings/ERCP findings as applicable. Results Among the 50 people studied, males and females were equal in number, and the majority belonged to the 41–60 year age group. The major cause for obstructive jaundice was choledocholithiasis. MDCT with reformatting techniques was very accurate in picking a mass as the cause for biliary obstruction and was able to differentiate a benign mass from a malignant one with high accuracy. There was 100% correlation between the CT diagnosis and the final diagnosis regarding the level and type of obstruction. MDCT was able to determine the cause of obstruction with an accuracy of 96%. Conclusions MDCT with good reformatting techniques has excellent accuracy in the evaluation of obstructive jaundice with regards to the level and cause of obstruction. PMID:27429673

  18. Noninvasive imaging of coronary arteries: current and future role of multi-detector row CT.

    PubMed

    Schoenhagen, Paul; Halliburton, Sandra S; Stillman, Arthur E; Kuzmiak, Stacie A; Nissen, Steven E; Tuzcu, E Murat; White, Richard D

    2004-07-01

    While invasive imaging techniques, especially selective conventional coronary angiography, will remain vital to planning and guiding catheter-based and surgical treatment of significantly stenotic coronary lesions, the comprehensive and serial assessment of asymptomatic or minimally symptomatic stages of coronary artery disease (CAD) for preventive purposes will eventually need to rely on noninvasive imaging techniques. Cardiovascular imaging with tomographic modalities, including computed tomography (CT) and magnetic resonance imaging, has great potential for providing valuable information. This review article will describe the current and future role of cardiac CT, and in particular that of multi-detector row CT, for imaging of atherosclerotic and other pathologic changes of the coronary arteries. It will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development.

  19. Mandibular arteriovenous malformation: A rare life-threatening condition depicted on multidetector CT angiography

    PubMed Central

    Dwivedi, Amit Nandan Dhar; Pandey, Anubha; Kumar, Ishan; Agarwal, Arjit

    2014-01-01

    Arteriovenous malformation (AVM) of the mandible is a rare and potentially life-threatening condition which can lead to massive hemorrhage. The following is a description where a large mandibular AVM presented with torrential bleeding following tooth extraction for caries. An orthopantomogram (OPG) was performed which was suggestive of aneurysmal bone cyst or ameloblastoma. A computed tomography (CT) angiography revealed a large mandibular AVM with submandibular extension. It is important for both clinicians and radiologist to be aware of this type of lesion that can have life-threatening complications. It is important to define the anatomical location and the feeder vessels of the entity in detail preoperatively. This communication highlights the common differential and use of multidetector CT (MDCT) angiography along with other imaging modalities to prevent a fatal hemorrhage and arrive at a correct diagnosis. PMID:24959049

  20. Cirsoid Aneurysm of Coronary Arteries Associated with Arterioventricular Fistula Evaluated by 64-Multidetector CT Coronary Angiography: Depiction of a Case

    SciTech Connect

    Marrone, Gianluca Mamone, Giuseppe; Milazzo, Mariapina; Caruso, Settimo; Baravoglia, Cesar Hernandez; Vitulo, Patrizio; Gridelli, Bruno; Luca, Angelo

    2009-05-15

    A female patient with severe pulmonary hypertension was admitted for lung transplant evaluation. As an incidental finding, the chest CT showed diffuse and dilated coronaries, not detected at previous echocardiography. A coronary CT angiography was then performed using a 64-multidetector computed tomography (MDCT) scanner to better evaluate the coronary tree. The images obtained after postprocessing demonstrated tremendously aneurysmatic and tortuous coronary arteries and the presence of a septal branch deepening into the myocardium and penetrating the right ventricle cavity, forming an abnormal arterioventricular fistula. A causal relation between the aneurysms and the fistula is suspected.

  1. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  2. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  3. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  4. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  5. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  6. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  7. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  8. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  9. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  10. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  11. Toroid cavity/coil NMR multi-detector

    DOEpatents

    Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.

    2007-09-18

    An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.

  12. Cam-type deformities: Concepts, criteria, and multidetector CT features.

    PubMed

    Mellado, J M; Radi, N

    2015-01-01

    Interpreting imaging studies of a painful hip requires detailed knowledge of the regional anatomy. Some variants of the proximal femur, such as cam-type deformities, can course asymptomatically or cause femoroacetabular impingement. The principal numerical criterion for defining cam-type deformities, the alpha angle, has some limitations. In this article, we review the anatomic variants of the anterior aspect of the proximal femur, focusing on cam-type deformities. Using diagrams and multidetector CT images, we describe the parameters that are useful for characterizing these deformities in different imaging techniques. We also discuss the potential correspondence of imaging findings of cam-type deformities with the terms coined by anatomists and anthropologists to describe these phenomena.

  13. Enhanced security for multi-detector quantum random number generators

    NASA Astrophysics Data System (ADS)

    Marangon, Davide G.; Vallone, Giuseppe; Zanforlin, Ugo; Villoresi, Paolo

    2016-11-01

    Quantum random number generators (QRNG) represent an advanced solution for randomness generation, which is essential in every cryptographic application. In this context, integrated arrays of single-photon detectors have promising applications as QRNGs based on the spatial detection of photons. For the employment of QRNGs in cryptography, it is necessary to have efficient methods to evaluate the so-called quantum min-entropy that corresponds to the amount of the true extractable quantum randomness from the QRNG. Here, we present an efficient method that allows the estimation of the quantum min-entropy for a multi-detector QRNG. In particular, we consider a scenario in which an attacker can control the efficiency of the detectors and knows the emitted number of photons. Eventually, we apply the method to a QRNG with 103 detectors.

  14. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations

    SciTech Connect

    Tzedakis, Antonis; Damilakis, John; Perisinakis, Kostas; Karantanas, Apostolos; Karabekios, Spiros; Gourtsoyiannis, Nicholas

    2007-04-15

    The purpose of this study was to evaluate the effect of z overscanning on normalized effective dose for pediatric patients undergoing multidetector-computed tomography (CT) examinations. Five commercially available mathematical anthropomorphic phantoms representing newborn, 1-, 5-, 10-, and 15-year-old patients and the Monte Carlo N-Particle (MCNP, version 4C2) radiation transport code were employed in the current study to simulate pediatric CT exposures. For all phantoms, axial and helical examinations at 120 kV tube voltage were simulated. Scans performed at 80 kV were also simulated. Sex-specific normalized effective doses were estimated for four standard CT examinations i.e., head-neck, chest, abdomen-pelvis, and trunk, for all pediatric phantoms. Data for both axial and helical mode acquisition were obtained. In the helical mode, z overscanning was taken into account. The validity of the Monte Carlo results was verified by comparison with dose data obtained using thermoluminescence dosimetry and a physical pediatric anthropomorphic phantom simulating a 10-year-old child. In all cases normalized effective dose values were found to increase with increasing z overscanning. The percentage differences in normalized data between axial and helical scans may reach 43%, 70%, 36%, and 26% for head-neck, chest, abdomen-pelvis, and trunk studies, respectively. Normalized data for female pediatric patients was in general higher compared to male patients for all ages, examined regions, and z overscanning values. For both male and female children, the normalized effective dose values were reduced as the age was increased. For the same typical exposure conditions, dose values decreased when lower tube voltage was used; for a 1-year-old child, for example, the effective dose was 3.8 times lower when 80 kV instead of 120 kV was used. Normalized data for the estimation of effective dose to pediatric patients undergoing standard axial and helical CT examinations on an

  15. Contrast enhanced multi-detector CT and MR findings of a well-differentiated pancreatic vipoma.

    PubMed

    Camera, Luigi; Severino, Rosa; Faggiano, Antongiulio; Masone, Stefania; Mansueto, Gelsomina; Maurea, Simone; Fonti, Rosa; Salvatore, Marco

    2014-10-28

    Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not specific, exact localization of the tumor by means of either computed tomography (CT) or magnetic resonance (MR) is pivotal for surgical planning. However, cross-sectional imaging findings are usually not specific and further characterization of the tumor may only be achieved by somatostatin-receptor scintigraphy (SRS). We report the case of a 70 years old female with a two years history of watery diarrhoea who was found to have a solid, inhomogeneously enhancing lesion at the level of the pancreatic tail at Gadolinium-enhanced MR (Somatom Trio 3T, Siemens, Germany). The tumor had been prospectively overlooked at a contrast-enhanced multi-detector CT (Aquilion 64, Toshiba, Japan) performed after i.v. bolus injection of only 100 cc of iodinated non ionic contrast media because of a chronic renal failure (3.4 mg/mL) but it was subsequently confirmed by SRS. The patient first underwent a successful symptomatic treatment with somatostatin analogues and was then submitted to a distal pancreasectomy with splenectomy to remove a capsulated whitish tumor which turned out to be a well-differentiated vipoma at histological and immuno-histochemical analysis.

  16. Multidetector CT cystography for imaging colovesical fistulas and iatrogenic bladder leaks.

    PubMed

    Tonolini, Massimo; Bianco, Roberto

    2012-04-01

    Multidetector computed tomography (MDCT) cystography currently represents the modality of choice to image the urinary bladder in traumatized patients. In this review we present our experience with MDCT cystography applications outside the trauma setting, particularly for diagnosing bladder fistulas and leaks. A detailed explanation is provided concerning exam preparation, acquisition technique, image reconstruction and interpretation. Colovesical fistulas most commonly occur as a complication of sigmoid diverticular disease, and often remain occult after extensive diagnostic work-up including cystoscopy and contrast-enhanced CT. We consistently achieved accurate preoperative visualization of colovesical fistulas using MDCT cystography. Urinary leaks and injuries represent a non-negligible occurrence after pelvic surgery, particularly obstetric and gynaecological procedures: in our experience MDCT cystography is useful to investigate iatrogenic bladder leaks or fistulas. In our opinion, MDCT cystography should be recommended as the first line modality for direct visualization or otherwise confident exclusion of both spontaneous enterovesical fistulas and bladder injuries following instrumentation procedures, obstetric or surgical interventions. Main Messages • Explanation of exam preparation, acquisition technique, image reconstruction and interpretation. • Preoperative visualization of colovesical fistulas, usually secondary to sigmoid diverticulitis. • Visualization or exclusion of iatrogenic bladder injuries following instrumentation or surgery.

  17. Variants of the popliteal artery terminal branches as detected by multidetector ct angiography

    PubMed Central

    Oztekin, Pelin Seher; Ergun, Elif; Cıvgın, Esra; Yigit, Hasan; Kosar, Pınar Nercis

    2015-01-01

    Objective To evaluate variants of the popliteal artery (PA) terminal branches with 64-multidetector computed tomographic angiography (64-MD CTA). Materials and Methods A total of 495 extremities (251 right, 244 left) of 253 patients undergoing a 64-MD CTA examination were included in the study. Of these, 242 extremities were evaluated bilaterally, whereas 11 were evaluated unilaterally. The terminal branching pattern of the PA was classified according to the classification scheme proposed by Kim; the distance between the medial tibial plateau and the origin of the anterior tibial artery (A) and the length of the tibioperoneal trunk (B) have been measured and recorded. Results In 459 cases (92.7%) branching of PA occurred distal to the knee joint (Type I); in 18 cases (2.8%) PA branching was superior to the knee joint (Type II); and hypoplasia of the PA branches was found in 27 cases (5.5%) (Type III). Among these types the most frequent branching patterns were Type IA (87.5%), Type IIIA (3.9%), and Type IB (3.8%). The ranges of A and B mean distances were 47.6 mm and 29.6 mm, respectively Conclusion Variations in popliteal artery terminal branching pattern occurred in 7.4% to 17.6% of patients. Pre-surgical detection of these variations with MD CTA may help to reduce the risk of iatrogenic arterial injury by enabling a better surgical treatment plan. PMID:28352741

  18. Normal or abnormal? Demystifying uterine and cervical contrast enhancement at multidetector CT.

    PubMed

    Yitta, Silaja; Hecht, Elizabeth M; Mausner, Elizabeth V; Bennett, Genevieve L

    2011-01-01

    Computed tomography (CT) is not generally advocated as the first-line imaging examination for disorders of the female pelvis. However, multidetector CT is often the modality of choice for evaluating nongynecologic pelvic abnormalities, particularly in emergent settings, in which all the pelvic organs are invariably assessed. Incidental findings of uterine and cervical contrast enhancement in such settings may easily be mistaken for abnormalities, given the broad spectrum of anatomic variants and enhancement patterns that may be seen in the normal uterus and cervix. The authors' review of CT and magnetic resonance (MR) imaging enhancement patterns, augmented by case examples from their clinical radiology practice, provides a solid foundation for understanding the spectrum of normal uterine and cervical appearances and avoiding potential pitfalls in the diagnosis of benign cervical lesions, adenomyosis, infection, malignancy, and postpartum effects. This information should help radiologists more confidently differentiate between normal and abnormal CT findings and, when CT findings are not definitive, offer appropriate recommendations for follow-up ultrasonography or MR imaging.

  19. Coronary artery calcium measurement with multi-detector row CT: in vitro assessment of effect of radiation dose.

    PubMed

    Hong, Cheng; Bae, Kyongtae T; Pilgram, Thomas K; Suh, Jongdae; Bradley, David

    2002-12-01

    The authors assessed in vitro the effect of radiation dose on coronary artery calcium quantification with multi-detector row computed tomography. A cardiac phantom with calcified cylinders was scanned at various milliampere second settings (20-160 mAs). A clear tendency was found for image noise to decrease as tube current increased (P <.001). No tendency was found for the Agatson score or calcium volume and mass errors to vary with tube current. Calcium measurements were not significantly affected by the choice of tube current. Calcium mass error was strongly correlated with calcium volume error (P <.001). The calcium mass measurement was more accurate and less variable than the calcium volume measurement.

  20. 75 FR 12676 - Establishment of Class E Airspace; Koyukuk, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    .../ . SUPPLEMENTARY INFORMATION: History On Wednesday, December 16, 2009, the FAA published a notice of proposed... Above the Surface of the Earth. * * * * * AAL AK E5 Koyukuk, AK Koyukuk Airport, AK (Lat. 64 52'33''...

  1. 75 FR 12678 - Revision of Class E Airspace; Dillingham, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    .../systemops/fs/alaskan/rulemaking/ . SUPPLEMENTARY INFORMATION: History On Wednesday, December 16, 2009, the... the Surface of the Earth. * * * * * AAL AK E5 Dillingham, AK Dillingham Airport, AK (Lat. 59 02'41''...

  2. Guideline for minimizing radiation exposure during acquisition of coronary artery calcium scans with the use of multidetector computed tomography: a report by the Society for Atherosclerosis Imaging and Prevention Tomographic Imaging and Prevention Councils in collaboration with the Society of Cardiovascular Computed Tomography.

    PubMed

    Voros, Szilard; Rivera, Juan J; Berman, Daniel S; Blankstein, Ron; Budoff, Matthew J; Cury, Ricardo C; Desai, Milind Y; Dey, Damini; Halliburton, Sandra S; Hecht, Harvey S; Nasir, Khurram; Santos, Raul D; Shapiro, Michael D; Taylor, Allen J; Valeti, Uma S; Young, Phillip M; Weissman, Gaby

    2011-01-01

    Coronary artery calcium (CAC) scanning is an important tool for risk stratification in intermediate-risk, asymptomatic subjects without previous coronary disease. However, the clinical benefit of improved risk prediction needs to be balanced against the risk of the use of ionizing radiation. Although there is increasing emphasis on the need to obtain CAC scans at low-radiation exposure to the patient, very few practical documents exist to aid laboratories and health care professionals on how to obtain such low-radiation scans. The Tomographic Imaging Council of the Society for Atherosclerosis Imaging and Prevention, in collaboration with the Prevention Council and the Society of Cardiovascular Computed Tomography, created a task force and writing group to generate a practical document to address parameters that can be influenced by careful attention to image acquisition. Patient selection for CAC scanning should be based on national guidelines. It is recommended that laboratories performing CAC examinations monitor radiation exposure (dose-length-product [DLP]) and effective radiation dose (E) in all patients. DLP should be <200 mGy × cm; E should average 1.0-1.5 mSv and should be <3.0 mSv. On most scanner platforms, CAC imaging should be performed in an axial mode with prospective electrocardiographic triggering, using tube voltage of 120 kVp. Tube current should be carefully selected on the basis of patient size, potentially using chest lateral width measured on the topogram. Scan length should be limited for the coverage of the heart only. When patients and imaging parameters are selected appropriately, CAC scanning can be performed with low levels of radiation exposure.

  3. Multidetector CT Findings of Bowel Transection in Blunt Abdominal Trauma

    PubMed Central

    Cho, Hyun Suk; Hong, Hye-Suk; Park, Mee Hyun; Ha, Hong Il; Yang, Ik; Lee, Yul; Jung, Ah Young; Hwang, Ji-Young

    2013-01-01

    Objective Though a number of CT findings of bowel and mesenteric injuries in blunt abdominal trauma are described in literature, no studies on the specific CT signs of a transected bowel have been published. In the present study we describe the incidence and new CT signs of bowel transection in blunt abdominal trauma. Materials and Methods We investigated the incidence of bowel transection in 513 patients admitted for blunt abdominal trauma who underwent multidetector CT (MDCT). The MDCT findings of 8 patients with a surgically proven complete bowel transection were assessed retrospectively. We report novel CT signs that are unique for transection, such as complete cutoff sign (transection of bowel loop), Janus sign (abnormal dual bowel wall enhancement, both increased and decreased), and fecal spillage. Results The incidence of bowel transection in blunt abdominal trauma was 1.56%. In eight cases of bowel transection, percentage of CT signs unique for bowel transection were as follows: complete cutoff in 8 (100%), Janus sign in 6 (100%, excluding duodenal injury), and fecal spillage in 2 (25%). The combination of complete cutoff and Janus sign were highly specific findings in patients with bowel transection. Conclusion Complete cut off and Janus sign are the unique CT findings to help detect bowel transection in blunt abdominal trauma and recognition of these findings enables an accurate and prompt diagnosis for emergency laparotomy leading to reduced mortality and morbidity. PMID:23901318

  4. Classification of lung area using multidetector-row CT images

    NASA Astrophysics Data System (ADS)

    Mukaibo, Tsutomu; Kawata, Yoshiki; Niki, Noboru; Ohmatsu, Hironobu; Kakinuma, Ryutaro; Eguchi, Kenji; Kaneko, Masahiro; Moriyama, Noriyuki

    2002-05-01

    Recently, we can get high quality images in the short time for the progress of X-ray CT scanner. And the three dimensional (3-D) analysis of pulmonary organs using multidetector-row CT (MDCT) images, is expected. This paper presents a method for classifying lung area into each lobe using pulmonary MDCT images of the whole lung area. It is possible to recognize the position of nodule by classifying lung area into these lobes. The structure of lungs differs on the right one and left one. The right lung is divided into three domains by major fissure and minor fissure. And, the left lung is divided into two domains by major fissure. Watching MDCT images carefully, we find that the surroundings of fissures have few blood vessels. Therefore, lung area is classified by extraction of the domain that the distance from pulmonary blood vessels is large and connective search of these extracted domains. These extraction and search are realized by 3-D weighted Hough transform.

  5. Recent technologic advances in multi-detector row cardiac CT.

    PubMed

    Halliburton, Sandra Simon

    2009-11-01

    Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.

  6. The validity of investigating occult hip fractures using multidetector CT

    PubMed Central

    Williams, Huw L M; Carpenter, Eleanor C; Lyons, Kathleen

    2016-01-01

    Objective: 10% of all hip fractures are occult on plain radiography, requiring further investigation to ascertain the diagnosis. MRI is presently the gold standard investigation, but frequently has disadvantages of time delay, resulting in increased hospital stay and mortality. Our aim was to establish whether multidetector CT (MDCT) is an appropriate first-line investigation of occult femoral neck (NOF) fractures. Methods: From 2013, we elected to use MDCT as the first-line investigation in patients believed to have an NOF fracture with negative plain films. These were reported by consultant musculoskeletal radiologists. We retrospectively analysed the data of consecutive patients presenting to the University Hospital of Wales, over 30 months with a clinical suspicion of a hip fracture. Results: 1443 patients were admitted during the study period. 209 (14.5%) patients had negative plain films requiring further investigation to exclude an NOF fracture, of which 199 patients had a CT. 93 patients had no fracture and 20 patients had isolated greater trochanter fractures. None of these patients progressed to develop an intracapsular femoral neck fracture at 4-month follow-up, although one patient sustained an extracapsular fracture following a high-energy fall whilst admitted. 26 femoral neck fractures were diagnosed on CT, whilst the remaining 60 patients were diagnosed with other pelvic ring fractures. Conclusion: When interpreted by experienced radiologists, MDCT has both sensitivity and specificity of 100%. Advances in knowledge: We recommend the use of MDCT as a safe and appropriate first-line investigation for NOF fractures. PMID:26838948

  7. Relationship between indexed epicardial fat volume and coronary plaque volume assessed by cardiac multidetector CT

    PubMed Central

    You, Seulgi; Sun, Joo Sung; Park, Seon Young; Baek, Yoolim; Kang, Doo Kyoung

    2016-01-01

    Abstract We explored whether baseline indexed epicardial fat volume (EFVi) and serial changes in EFVi were associated with increase in coronary plaque volume as assessed by multidetector computed tomography. We retrospectively reviewed 87 patients with coronary artery plaque, identified during either baseline or follow-up cardiac computed tomography (CT) examinations. Each plaque volume was measured in volumetric units using a semiautomatic software tool. EFVi was quantified by calculating the total volume of epicardial tissue of CT density −190 to −30 HU, indexed to the body surface area. Clinical cardiovascular risk factors were extracted by medical record review at the time of the cardiac CT examinations. The relationship between EFVi and coronary plaque volume was explored by regression analysis. Although the EFVi did not change significantly from baseline to the time of the follow-up CT (65.7 ± 21.8 vs 66.0 ± 21.8 cm3/m3, P = 0.620), the plaque volumes were increased significantly on the follow-up CT scans. The annual change in EFVi was not accompanied by a parallel change in coronary plaque volume (P = 0.096–0.500). On univariate analysis, smoking, hypercholesterolemia, 10-year coronary heart disease risk, obesity, and baseline EFVi predicted rapid increases in lipid-rich and fibrous plaque volumes. On multivariate analysis, baseline EFVi (odds ratio = 1.029, P = 0.016) was an independent predictor of a rapid increase in lipid-rich plaque volume. EFVi was shown to be an independent predictor of a rapid increase in lipid-rich plaque volume. However, changes in EFVi were not associated with parallel changes in coronary plaque volume. PMID:27399137

  8. 76 FR 75447 - Amendment of Class E Airspace; Emmonak, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-02

    ... Emmonak, AK Emmonak Airport, AK (Lat. 62 47'10'' N., long. 164 29'27'' W.) Emmonak VOR/DME (Lat. 62 47'05... Federal Aviation Administration 14 CFR Part 71 Amendment of Class E Airspace; Emmonak, AK AGENCY: Federal... Emmonak, AK. The revision of two standard instrument approach procedures at the Emmonak Airport has...

  9. New absorbed dose measurement with cylindrical water phantoms for multidetector CT

    NASA Astrophysics Data System (ADS)

    Ohno, Takeshi; Araki, Fujio; Onizuka, Ryota; Hioki, Kazunari; Tomiyama, Yuuki; Yamashita, Yusuke

    2015-06-01

    The aim of this study was to develop new dosimetry with cylindrical water phantoms for multidetector computed tomography (MDCT). The ionization measurement was performed with a Farmer ionization chamber at the center and four peripheral points in the body-type and head-type cylindrical water phantoms. The ionization was converted to the absorbed dose using a 60Co absorbed-dose-to-water calibration factor and Monte Carlo (MC) -calculated correction factors. The correction factors were calculated from MDCT (Brilliance iCT, 64-slice, Philips Electronics) modeled with GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. The spectrum of incident x-ray beams and the configuration of a bowtie filter for MDCT were determined so that calculated photon intensity attenuation curves for aluminum (Al) and calculated off-center ratio (OCR) profiles in air coincided with those measured. The MC-calculated doses were calibrated by the absorbed dose measured at the center in both cylindrical water phantoms. Calculated doses were compared with measured doses at four peripheral points and the center in the phantom for various beam pitches and beam collimations. The calibration factors and the uncertainty of the absorbed dose determined using this method were also compared with those obtained by CTDIair (CT dose index in air). Calculated Al half-value layers and OCRs in air were within 0.3% and 3% agreement with the measured values, respectively. Calculated doses at four peripheral points and the centers for various beam pitches and beam collimations were within 5% and 2% agreement with measured values, respectively. The MC-calibration factors by our method were 44-50% lower than values by CTDIair due to the overbeaming effect. However, the calibration factors for CTDIair agreed within 5% with those of our method after correction for the overbeaming effect. Our method makes it possible to directly measure the absorbed dose for MDCT and is more robust and accurate than the

  10. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    SciTech Connect

    Flohr, T. G.; Stierstorfer, K.; Suess, C.; Schmidt, B.; Primak, A. N.; McCollough, C. H.

    2007-05-15

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution.

  11. Multi-detector row CT scanning in Paleoanthropology at various tube current settings and scanning mode.

    PubMed

    Badawi-Fayad, J; Yazbeck, C; Balzeau, A; Nguyen, T H; Istoc, A; Grimaud-Hervé, D; Cabanis, E- A

    2005-12-01

    The purpose of this study was to determine the optimal tube current setting and scanning mode for hominid fossil skull scanning, using multi-detector row computed tomography (CT). Four fossil skulls (La Ferrassie 1, Abri Pataud 1, CroMagnon 2 and Cro-Magnon 3) were examined by using the CT scanner LightSpeed 16 (General Electric Medical Systems) with varying dose per section (160, 250, and 300 mAs) and scanning mode (helical and conventional). Image quality of two-dimensional (2D) multiplanar reconstructions, three-dimensional (3D) reconstructions and native images was assessed by four reviewers using a four-point grading scale. An ANOVA (analysis of variance) model was used to compare the mean score for each sequence and the overall mean score according to the levels of the scanning parameters. Compared with helical CT (mean score=12.03), the conventional technique showed sustained poor image quality (mean score=4.17). With the helical mode, we observed a better image quality at 300 mAs than at 160 in the 3D sequences (P=0.03). Whereas in native images, a reduction in the effective tube current induced no degradation in image quality (P=0.05). Our study suggests a standardized protocol for fossil scanning with a 16 x 0.625 detector configuration, a 10 mm beam collimation, a 0.562:1 acquisition mode, a 0.625/0.4 mm slice thickness/reconstruction interval, a pitch of 5.62, 120 kV and 300 mAs especially when a 3D study is required.

  12. Study of statistical properties of hybrid statistic in coherent multidetector compact binary coalescences search

    NASA Astrophysics Data System (ADS)

    Haris, K.; Pai, Archana

    2016-05-01

    In this article, we revisit the coherent gravitational wave search problem of compact binary coalescences with multidetector network consisting of advanced interferometers like LIGO-Virgo. Based on the loss of the optimal multidetector signal-to-noise ratio (SNR), we construct a hybrid statistic as a best of maximum-likelihood-ratio (MLR) statistic tuned for face-on and face-off binaries. The statistical properties of the hybrid statistic is studied. The performance of this hybrid statistic is compared with that of the coherent MLR statistic for generic inclination angles. Owing to the single synthetic data stream, the hybrid statistic gives few false alarms compared to the multidetector MLR statistic and small fractional loss in the optimum SNR for a large range of binary inclinations. We demonstrate that, for a LIGO-Virgo network and binary inclination ɛ <7 0 ° and ɛ >11 0 ° , the hybrid statistic captures more than 98% of the network optimum matched filter SNR with a low false alarm rate. The Monte Carlo exercise with two distributions of incoming inclination angles—namely, U [cos ɛ ] and a more realistic distribution proposed by B. F. Schutz [Classical Quantum Gravity 28, 125023 (2011)]—are performed with the hybrid statistic and give approximately 5% and 7% higher detection probabilities, respectively, compared to the two stream multidetector MLR statistic for a fixed false alarm probability of 1 0-5.

  13. Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

    PubMed Central

    Kim, Mija; YI, Won-Jin; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul

    2012-01-01

    Purpose This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). Materials and Methods MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. Results All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Conclusion Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements. PMID:22474645

  14. AK-cut crystal resonators

    NASA Technical Reports Server (NTRS)

    Kahan, A.; Euler, F. K.

    1983-01-01

    Calculations have predicted the existence of crystallographically doubly rotated quartz orientations with turnover temperatures which are considerably less sensitive to angular misorientation then comparable AT- or BT-cuts. These crystals are arbitrarily designated as the AK-cut. Experimental data is given for seven orientations, phi-angle variations between 30-46 deg and theta-angle variations between 21-28 deg measured on 3.3-3.4 MHz fundamental mode resonators vibrating in the thickness shear c-mode. The experimental turnover temperatures of these resonators are between 80 C and 150 C, in general agreement with calculated values. The normalized frequency change as a function of temperature has been fitted with a cubic equation.

  15. Dual-energy CT revisited with multidetector CT: review of principles and clinical applications.

    PubMed

    Karçaaltıncaba, Muşturay; Aktaş, Aykut

    2011-09-01

    Although dual-energy CT (DECT) was first conceived in the 1970s, it was not widely used for CT indications. Recently, the simultaneous acquisition of volumetric dual-energy data has been introduced using multidetector CT (MDCT) with two X-ray tubes and rapid kVp switching (gemstone spectral imaging). Two major advantages of DECT are material decomposition by acquiring two image series with different kVp and the elimination of misregistration artifacts. Hounsfield unit measurements by DECT are not absolute and can change depending on the kVp used for an acquisition. Typically, a combination of 80/140 kVp is used for DECT, but for some applications, 100/140 kVp is preferred. In this study, we summarized the clinical applications of DECT and included images that were acquired using the dual-source CT and rapid kVp switching. In general, unenhanced images can be avoided by using DECT for body and neurological applications; iodine can be removed from the image, and a virtual, non-contrast (water) image can be obtained. Neuroradiological applications allow for the removal of bone and calcium from the carotid and brain CT angiography. Thorax applications include perfusion imaging in patients with pulmonary thromboemboli and other chest diseases, xenon ventilation-perfusion imaging and solitary nodule characterization. Cardiac applications include dual-energy cardiac perfusion, viability and cardiac iron detection. The removal of calcific plaques from arteries, bone removal and aortic stent graft evaluation may be achieved in the vascular system. Abdominal applications include the detection and characterization of liver and pancreas masses, the diagnosis of steatosis and iron overload, DECT colonoscopy and CT cholangiography. Urinary system applications are urinary calculi characterization (uric acid vs. non-uric acid), renal cyst characterization and mass characterization. Musculoskeletal applications permit the differentiation of gout from pseudogout and a reduction of

  16. 76 FR 65944 - Establishment of Class E Airspace; Tatitlek, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-25

    ... airspace at Tatitlek, AK, to accommodate the creation of one standard instrument approach procedure at the... airspace at the Tatitlek Airport, Tatitlek, AK, to accommodate the creation of a standard...

  17. 78 FR 16399 - Amendment of Class E Airspace; Unalakleet, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-15

    ... INFORMATION: History On May 9, 2012, the FAA published in the Federal Register a notice of proposed rulemaking... 700 feet or more above the surface of the earth. * * * * * AAL AK E5 Unalakleet, AK Unalakleet...

  18. 75 FR 12679 - Revision of Class E Airspace; Iliamna, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    .../rulemaking/ . SUPPLEMENTARY INFORMATION: History On Monday, December 21, 2009, the FAA published a notice of... Upward From 700 Feet or More Above the Surface of the Earth. * * * * * AAL AK E5 Iliamna, AK...

  19. 77 FR 6 - Amendment of Class E Airspace; Galbraith Lake, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    .... * * * * * AAL AK E5 Galbraith Lake, AK Galbraith Lake Airport, AK (Lat. 68 28'47'' N., long. 149 29'24'' W... Federal Aviation Administration 14 CFR Part 71 Amendment of Class E Airspace; Galbraith Lake, AK AGENCY... airspace at Galbraith Lake, AK. The creation of two standard instrument approach procedures at...

  20. 76 FR 54148 - Proposed Amendment of Class E Airspace; Emmonak, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... AK E5 Emmonak, AK Emmonak Airport, AK (Lat. 62 47'10'' N., long. 164 29'27'' W.) Emmonak VOR/DME (Lat... Federal Aviation Administration 14 CFR Part 71 Proposed Amendment of Class E Airspace; Emmonak, AK AGENCY... action proposes to revise Class E airspace at Emmonak, AK. The amendment of two standard...

  1. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware.

    PubMed

    Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic

    2006-12-01

    Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration.

  2. ISEE-C HKH high energy cosmic rays. [multidetector particle telescope experiment

    NASA Technical Reports Server (NTRS)

    Greiner, D. E.; Bieser, F. S.; Heckman, H. H.

    1978-01-01

    The paper describes the ISEE-C multidetector cosmic ray telescope experiment. The HKH particle identifier sensor array is designed to identify the charge and mass of incident cosmic ray nuclei from H-1 to Ni-64 over the energy range of approximately 20 to 500 MeV/nucleon. Particle identification is based on the multiple energy loss technique. The scientific aspects of the experiment are briefly reviewed and consideration is given to the flight hardware, including sensors, event encoding, buffer memory, redundancy and commandability, and packaging.

  3. 76 FR 35936 - Alaska Disaster #AK-00020

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-20

    ... Doc No: 2011-15127] U.S. SMALL BUSINESS ADMINISTRATION [Disaster Declaration 12632 and 12633] Alaska Disaster AK-00020 AGENCY: U.S. Small Business Administration. ACTION: Notice. SUMMARY: This is a Notice of... to: U.S. Small Business Administration, Processing and Disbursement Center, 14925 Kingsport...

  4. Assessment of coronary bypass graft patency by first-line multi-detector computed tomography.

    PubMed

    Pesenti-Rossi, D; Baron, N; Georges, J-L; Augusto, S; Gibault-Genty, G; Livarek, B

    2014-11-01

    The purpose of the study was to assess whether a strategy based on a MDCT performed routinely before CA can reduce the radiation dose during the CA, without increased global exposure in patients who need imaging of CABG. A total of 147 consecutive patients were included. The radiation dose during CA (KAP 12.1 vs 22.0 Gy/cm(2), P<.01) and the volume of iodinated contrast (155 vs 200 mL, P<.02) were reduced when preceded by a MDCT. Patients' cumulative exposures were not different in the 2 strategies (5.0 vs 5.1 mSv, P=.76). MDCT performed in first line is a valuable strategy for the assessment of CABG.

  5. The pre-main sequence spectroscopic binary AK Scorpii revisited

    NASA Astrophysics Data System (ADS)

    Alencar, S. H. P.; Melo, C. H. F.; Dullemond, C. P.; Andersen, J.; Batalha, C.; Vaz, L. P. R.; Mathieu, R. D.

    2003-10-01

    We present an analysis of 32 high-resolution echelle spectra of the pre-main sequence spectroscopic binary AK Sco obtained during 1998 and 2000, as well as a total of 72 photoelectric radial-velocity observations from the period 1986-1994. These data allow considerable improvement of the period and other orbital parameters of AK Sco. Our analysis also includes eight series of photometric observations in the uvby and Geneva seven-color systems from 1987, 1989, 1990, 1992, 1994 and 1997. No eclipses or other periodic variations are seen in the photometry, but the well-determined HIPPARCOS parallax allows us to constrain the orbital inclination of the system to the range 65 degr < i < 70 degr, leading to the following physical parameters for the two near-identical stars: M =1.35 +/- 0.07 \\msun, R =1.59 +/- 0.35 \\rsun, and vsin i =18.5 +/- 1.0 \\kmsn. Disk models have been fit to the spectral energy distribution of AK Sco from 350 nm to 1100 mu m. The above stellar parameters permit a consistent solution with an inner rim temperature of 1250 K, instead of the usual 1500 K corresponding to the dust evaporation temperature. Dynamical effects due to tidal interaction of the binary system are supposed to be responsible for pushing the inner disk radius outwards. Combining simultaneous photometric and spectroscopic data sets allows us to compute the dust obscuration in front of each star at several points over the orbit. The results demonstrate the existence of substructure at scales of just a single stellar diameter, and also that one side of the orbit is more heavily obscured than the other. The spectrum of AK Sco exhibits emission and absorption lines that show substantial variety and variability in shape. The accretion-related lines may show both outflow and infall signatures. The system displays variations at the binary orbital period in both the photospheric and accretion-related line intensities and equivalent widths, although with appreciable scatter. The periodic

  6. Split-Bolus Single-Pass Multidetector-Row CT Protocol for Diagnosis of Acute Pulmonary Embolism

    PubMed Central

    Scialpi, Michele; Rebonato, Alberto; Cagini, Lucio; Brunese, Luca; Piscioli, Irene; Pierotti, Luisa; Bellantonio, Lucio; D’Andrea, Alfredo; Rotondo, Antonio

    2016-01-01

    Background: Currently computed tomography pulmonary angiography (CTPA) has become a widely accepted clinical tool in the diagnosis of acute pulmonary embolism (PE). Objectives: To report split-bolus single-pass 64-multidetector-row CT (MDCT) protocol for diagnosis of PE. Patients and Methods: MDCT split-bolus results in 40 patients suspicious of PE were analyzed in terms of image quality of target pulmonary vessels (TPVs) and occurrence and severity of flow-related artifact, flow-related artifact, false filling defect of the pulmonary veins and beam hardening streak artifacts. Dose radiation to patients was calculated. Results: MDCT split-bolus protocol allowed diagnostic images of high quality in all cases. Diagnosis of PE was obtained in 22 of 40 patients. Mean attenuation for target vessels was higher than 250 HU all cases: 361 ± 98 HU in pulmonary artery trunk (PAT); 339 ± 93 HU in right pulmonary artery (RPA); 334 ± 100 HU in left pulmonary artery (LPA). Adequate enhancement was obtained in the right atrium (RA):292 ± 83 HU; right pulmonary vein (RPV): 302 ± 91 HU, and left pulmonary vein (LPV): 291 ± 83 HU. The flow related artifacts and the beam hardening streak artifacts have been detected respectively in 4 and 25 patients. No false filling defect of the pulmonary veins was revealed. Conclusion: MDCT split-bolus technique by simultaneous opacification of pulmonary arteries and veins represents an accurate technique for diagnosis of acute PE, removes the false filling defects of the pulmonary veins, and reduces flow related artifacts. PMID:27110334

  7. 78 FR 50322 - Amendment of Class E Airspace; Point Thomson, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-19

    ... Thomson, AK. New Area Navigation (RNAV) Global Positioning System (GPS) standard instrument approach... Airstrip Airport, Point Thomson, AK, to accommodate aircraft using new RNAV (GPS) standard...

  8. A Clinical Evaluation of Cone Beam Computed Tomography

    DTIC Science & Technology

    2013-07-31

    multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 2011;40:67-75...submitted to the Faculty of the Endodontics Graduate Program Naval Postgraduate Dental School Uniformed Services University of the Health Sciences...in partial fulfillment of the requirements of the degree of Master of Science in Oral Biology June 2013 Naval Postgraduate Dental

  9. [Multidetector row CT in assessment of coronary artery calcification on hemodialisis].

    PubMed

    Caro, P; Delgado, R; Dapena, F; Núñez, A

    2007-01-01

    Vascular calcification is a strong predictor of cardiovascular and all-cause mortality. Coronary artery calcification is more frequent, more extensive and progresses more rapidly in CKD than in general population. They are also considered a marker of coronary heart disease, with high prevalence and functional significance. It suggests that detection and surveillance may be worthwhile in general clinical practice. New non-invasive image techniques, like Multi-detector row CT, a type of spiral scanner, assess density and volume of calcification at multiple sites and allow quantitative scoring of vascular calcification using calcium scores analogous to those from electron-beam CT. We have assessed and quantified coronary artery calcification with 16 multidetector row CT in 44 patients on hemodialysis and their relationship with several cardiovascular risk factors. Coronary artery calcification prevalence was of 84 % with mean calcium score of 1580 +/- 2010 ( r 0-9844) with calcium score > 400 in 66% of patients. It was usually multiple, affecting more than two vessels in more than 50%. In all but one patient, left anterior descending artery was involved with higher calcium score level at right coronary artery. Advanced age, male, diabetes, smoking, more morbidity, cerebrovascular disease previous, and calcium-binders phosphate and analogous vitamin D treatment would seem to be associated with coronary artery calcification. Coronary artery calcification is very frequent and extensive, usually multiple and associated to modifiable risk factors in hemodialysis patients. Multi-detector-row CT seems an effective, suitable, readily applicable method to assess and quantify coronary artery calcification.

  10. Lymphoplasmacytic sclerosing pancreatitis (autoimmune pancreatitis): evaluation with multidetector CT.

    PubMed

    Kawamoto, Satomi; Siegelman, Stanley S; Hruban, Ralph H; Fishman, Elliot K

    2008-01-01

    Lymphoplasmacytic sclerosing pancreatitis is a form of chronic pancreatitis characterized by a mixed inflammatory infiltrate that centers on the pancreatic ducts. It is a cause of benign pancreatic disease that can clinically mimic pancreatic cancer. Preoperative detection of lymphoplasmacytic sclerosing pancreatitis is important because patients usually respond to steroid therapy. Patients with lymphoplasmacytic sclerosing pancreatitis are often referred for computed tomography (CT) when they are suspected of having a pancreatic or biliary neoplasm; therefore, it is important to search for potential findings suggestive of lymphoplasmacytic sclerosing pancreatitis when typical findings of a pancreatic or biliary neoplasm are not found. Typical CT findings include diffuse or focal enlargement of the pancreas without dilatation of the main pancreatic duct. Focal enlargement is most commonly seen in the head of the pancreas, and the involved pancreas on contrast material-enhanced CT images may be iso-attenuating relative to the rest of the pancreas, or hypo-attenuating, especially during the early postcontrast phase. Thickening and contrast enhancement of the wall of the common bile duct and gallbladder may reflect inflammatory infiltrate and fibrosis associated with lymphoplasmacytic sclerosing pancreatitis. There are several features seen at CT that may help to differentiate lymphoplasmacytic sclerosing pancreatitis from pancreatic cancer, such as diffuse enlargement of the pancreas with minimal peripancreatic stranding in patients with obstructive jaundice, an absence of significant pancreatic atrophy, and an absence of significant main pancreatic duct dilatation. When these findings are encountered, clinical, other imaging, and serologic data should be evaluated.

  11. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    NASA Astrophysics Data System (ADS)

    Belinato, W.; Santos, W. S.; Paschoal, C. M. M.; Souza, D. N.

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current-time product (mAs) and pitch during PET/CT procedures.

  12. Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

    PubMed

    Kefer, Joelle M; Coche, Emmanuel; Vanoverschelde, Jean-Louis J; Gerber, Bernhard L

    2007-01-01

    The purpose of this study was to assess the diagnostic accuracy of 16-slice multidetector-row computed tomography (MDCT) for detecting in-stent restenosis. Fifty patients with 69 previously implanted coronary stents underwent 16-slice MDCT before quantitative coronary angiography (QCA). Diagnostic accuracy of MDCT for detection of in-stent restenosis defined as >50% lumen diameter stenosis (DS) in stented and nonstented coronary segments >1.5-mm diameter was computed using QCA as reference. According to QCA, 18/69 (25%) stented segments had restenosis. In addition, 33/518 (6.4%) nonstented segments had >50% DS. In-stent restenosis was correctly identified on MDCT images in 12/18 stents, and absence of restenosis was correctly identified in 50/51 stents. Stenosis in native coronary arteries was correctly identified in 22/33 segments and correctly excluded in 482/485 segments. Thus, sensitivity (67% vs 67% p=1.0), specificity (98% vs 99%, p=0.96) and overall diagnostic accuracy (90% vs 97%, p=0.68) was similarly high for detecting in-stent restenosis as for detecting stenosis in nonstented coronary segments. MDCT has similarly high diagnostic accuracy for detecting in-stent restenosis as for detecting coronary artery disease in nonstented segments. This suggests that MDCT could be clinically useful for identification of restenosis in patients after coronary stenting.

  13. 40 CFR Appendixes A-K to Part 51 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false A Appendixes A-K to Part 51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Appendixes A-K to Part 51...

  14. 76 FR 8627 - Revision of Class E Airspace; Platinum, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    ... Federal Aviation Administration 14 CFR Part 71 Revision of Class E Airspace; Platinum, AK AGENCY: Federal... Platinum, AK, to accommodate the addition of a Standard Instrument Approach Procedure (SIAP), at the Platinum Airport. The FAA is taking this action to enhance safety and management of Instrument Flight...

  15. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  16. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  17. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  18. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  19. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  20. 76 FR 61258 - Revision of Class E Airspace; Allakaket, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-04

    ... Federal Aviation Administration 14 CFR Part 71 Revision of Class E Airspace; Allakaket, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action revises Class E airspace at Allakaket, AK, to accommodate the amendment of one Standard Instrument Approach Procedure at the...

  1. 75 FR 33165 - Revision of Class E Airspace; Galena, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-11

    ... revising Class E airspace at Edward G. Pitka Sr. Airport, AK, to accommodate three amended SIAPs and one... TRANSPORTATION Federal Aviation Administration 14 CFR Part 71 Revision of Class E Airspace; Galena, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final Rule. SUMMARY: This action revises Class...

  2. 76 FR 60714 - Revision of Class E Airspace; Northway, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... Federal Aviation Administration 14 CFR Part 71 Revision of Class E Airspace; Northway, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action revises Class E airspace at Northway, AK, to accommodate the amendment of one Standard Instrument Approach Procedure at the...

  3. 76 FR 8626 - Revision of Class E Airspace; Shungnak, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    ... Federal Aviation Administration 14 CFR Part 71 Revision of Class E Airspace; Shungnak, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action revises Class E airspace at..., Box 14, Anchorage, AK 99513-7587; telephone number (907) 271-5898; fax: (907) 271-2850; e-...

  4. Pulmonary arterial hypertension: an imaging review comparing MR pulmonary angiography and perfusion with multidetector CT angiography.

    PubMed

    Junqueira, F P; Lima, C M A O; Coutinho, A C; Parente, D B; Bittencourt, L K; Bessa, L G P; Domingues, R C; Marchiori, E

    2012-11-01

    Pulmonary hypertension (PH) is a progressive disease that leads to substantial morbidity and eventual death. Pulmonary multidetector CT angiography (MDCTA), pulmonary MR angiography (MRA) and MR-derived pulmonary perfusion (MRPP) imaging are non-invasive imaging techniques for the differential diagnosis of PH. MDCTA is considered the gold standard for the diagnosis of pulmonary embolism, one of the most common causes of PH. MRA and MRPP are promising techniques that do not require the use of ionising radiation or iodinated contrast material, and can be useful for patients for whom such material cannot be used. This review compares the imaging aspects of pulmonary MRA and 64-row MDCTA in patients with chronic thromboembolic or idiopathic PH.

  5. Pulmonary arterial hypertension: an imaging review comparing MR pulmonary angiography and perfusion with multidetector CT angiography

    PubMed Central

    Junqueira, F P; Lima, C M A O; Coutinho, A C; Parente, D B; Bittencourt, L K; Bessa, L G P; Domingues, R C; Marchiori, E

    2012-01-01

    Pulmonary hypertension (PH) is a progressive disease that leads to substantial morbidity and eventual death. Pulmonary multidetector CT angiography (MDCTA), pulmonary MR angiography (MRA) and MR-derived pulmonary perfusion (MRPP) imaging are non-invasive imaging techniques for the differential diagnosis of PH. MDCTA is considered the gold standard for the diagnosis of pulmonary embolism, one of the most common causes of PH. MRA and MRPP are promising techniques that do not require the use of ionising radiation or iodinated contrast material, and can be useful for patients for whom such material cannot be used. This review compares the imaging aspects of pulmonary MRA and 64-row MDCTA in patients with chronic thromboembolic or idiopathic PH. PMID:22932061

  6. Multidetector CT of expected findings and complications after contemporary inguinal hernia repair surgery

    PubMed Central

    Tonolini, Massimo

    2016-01-01

    Inguinal hernia repair (IHR) with prosthetic mesh implantation is the most common procedure in general surgery, and may be performed using either an open or laparoscopic approach. This paper provides an overview of contemporary tension-free IHR techniques and materials, and illustrates the expected postoperative imaging findings and iatrogenic injuries. Emphasis is placed on multidetector CT, which represents the ideal modality to comprehensively visualize the operated groin region and deeper intra-abdominal structures. CT consistently depicts seroma, mesh infections, hemorrhages, bowel complications and urinary bladder injuries, and thus generally provides a consistent basis for therapeutic choice. Since radiologists are increasingly requested to investigate suspected iatrogenic complications, this paper aims to provide an increased familiarity with early CT studies after IHR, including complications and normal postoperative appearances such as focal pseudolesions, in order to avoid misinterpretation and inappropriate management. PMID:27460285

  7. Collimated prompt gamma TOF measurements with multi-slit multi-detector configurations

    NASA Astrophysics Data System (ADS)

    Krimmer, J.; Chevallier, M.; Constanzo, J.; Dauvergne, D.; De Rydt, M.; Dedes, G.; Freud, N.; Henriquet, P.; La Tessa, C.; Létang, J. M.; Pleskač, R.; Pinto, M.; Ray, C.; Reithinger, V.; Richard, M. H.; Rinaldi, I.; Roellinghoff, F.; Schuy, C.; Testa, E.; Testa, M.

    2015-01-01

    Longitudinal prompt-gamma ray profiles have been measured with a multi-slit multi-detector configuration at a 75 MeV/u 13C beam and with a PMMA target. Selections in time-of-flight and energy have been applied in order to discriminate prompt-gamma rays produced in the target from background events. The ion ranges which have been extracted from each individual detector module agree amongst each other and are consistent with theoretical expectations. In a separate dedicated experiment with 200 MeV/u 12C ions the fraction of inter-detector scattering has been determined to be on the 10%-level via a combination of experimental results and simulations. At the same experiment different collimator configurations have been tested and the shielding properties of tungsten and lead for prompt-gamma rays have been measured.

  8. High resolution multidetector CT aided tissue analysis and quantification of lung fibrosis

    NASA Astrophysics Data System (ADS)

    Zavaletta, Vanessa A.; Karwoski, Ronald A.; Bartholmai, Brian; Robb, Richard A.

    2006-03-01

    Idiopathic pulmonary fibrosis (IPF, also known as Idiopathic Usual Interstitial Pneumontis, pathologically) is a progressive diffuse lung disease which has a median survival rate of less than four years with a prevalence of 15-20/100,000 in the United States. Global function changes are measured by pulmonary function tests and the diagnosis and extent of pulmonary structural changes are typically assessed by acquiring two-dimensional high resolution CT (HRCT) images. The acquisition and analysis of volumetric high resolution Multi-Detector CT (MDCT) images with nearly isotropic pixels offers the potential to measure both lung function and structure. This paper presents a new approach to three dimensional lung image analysis and classification of normal and abnormal structures in lungs with IPF.

  9. 98. View of IBM digital computer model 7090 magnet core ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    98. View of IBM digital computer model 7090 magnet core installation. ITT Artic Services, Inc., Official photograph BMEWS Site II, Clear, AK, by unknown photographer, 17 September 1965. BMEWS, clear as negative no. A-6606. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  10. 97. View of International Business Machine (IBM) digital computer model ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    97. View of International Business Machine (IBM) digital computer model 7090 magnetic core installation, international telephone and telegraph (ITT) Artic Services Inc., Official photograph BMEWS site II, Clear, AK, by unknown photographer, 17 September 1965, BMEWS, clear as negative no. A-6604. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  11. Estimating radiation dose to organs of patients undergoing conventional and novel multidetector CT exams using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Angel, Erin

    Advances in Computed Tomography (CT) technology have led to an increase in the modality's diagnostic capabilities and therefore its utilization, which has in turn led to an increase in radiation exposure to the patient population. As a result, CT imaging currently constitutes approximately half of the collective exposure to ionizing radiation from medical procedures. In order to understand the radiation risk, it is necessary to estimate the radiation doses absorbed by patients undergoing CT imaging. The most widely accepted risk models are based on radiosensitive organ dose as opposed to whole body dose. In this research, radiosensitive organ dose was estimated using Monte Carlo based simulations incorporating detailed multidetector CT (MDCT) scanner models, specific scan protocols, and using patient models based on accurate patient anatomy and representing a range of patient sizes. Organ dose estimates were estimated for clinical MDCT exam protocols which pose a specific concern for radiosensitive organs or regions. These dose estimates include estimation of fetal dose for pregnant patients undergoing abdomen pelvis CT exams or undergoing exams to diagnose pulmonary embolism and venous thromboembolism. Breast and lung dose were estimated for patients undergoing coronary CTA imaging, conventional fixed tube current chest CT, and conventional tube current modulated (TCM) chest CT exams. The correlation of organ dose with patient size was quantified for pregnant patients undergoing abdomen/pelvis exams and for all breast and lung dose estimates presented. Novel dose reduction techniques were developed that incorporate organ location and are specifically designed to reduce close to radiosensitive organs during CT acquisition. A generalizable model was created for simulating conventional and novel attenuation-based TCM algorithms which can be used in simulations estimating organ dose for any patient model. The generalizable model is a significant contribution of this

  12. Artifact-Free and Detection-Profile-Independent Higher-Order Fluorescence Correlation Spectroscopy for Microsecond-Resolved Kinetics. 1. Multidetector and Sub-Binning Approach.

    PubMed

    Abdollah-Nia, Farshad; Gelfand, Martin P; Van Orden, Alan

    2017-03-10

    Fluorescence correlation spectroscopy (FCS) is a powerful tool in the time-resolved analysis of nonreacting or reacting molecules in solution, based on fluorescence intensity fluctuations. However, conventional (second-order) FCS alone is insufficient to measure all parameters needed to describe a reaction or mixture, including concentrations, fluorescence brightnesses, and forward and reverse rate constants. For this purpose, correlations of higher powers of fluorescence intensity fluctuations can be calculated to yield additional information from the single-photon data stream collected in an FCS experiment. To describe systems of diffusing and reacting molecules, considering cumulants of fluorescence intensity results in simple expressions in which the reaction and diffusion parts factorize. The computation of higher-order correlations in experiments is hindered by shot-noise and common detector artifacts, the effects of which become worse with increasing order. In this article, we introduce a technique to calculate artifact-free higher-order correlation functions with improved time resolution, and without any need for modeling and calibration of detector artifacts. The technique is formulated for general multidetector experiments and verified in both two-detector and single-detector configurations. Good signal-to-noise ratio is achieved down to 1 μs in correlation curves up to order (2, 2). This capability makes possible a variety of new measurements including multicomponent analysis and fast reaction kinetics, as demonstrated in a companion article (10.1021/acs.jpcb.7b00408).

  13. [Comparison of a dental cone beam CT with a multi-detector row CT on effective doses and physical image quality].

    PubMed

    Yoshida, Yutaka; Tokumori, Kenji; Okamura, Kazutoshi; Yoshiura, Kazunori

    2011-01-01

    The purpose of this study was to compare a dental cone beam computed tomography (dental CBCT) and a multi-detector row CT (MDCT) using effective doses and physical image quality. A dental mode (D-mode) and an implant mode (I-mode) were employed for calculating effective doses. Field of view (FOV) size of the MDCT was 150 mm. Three types of images were obtained using 3 different reconstruction functions: FC1 (for abdomen images), FC30 (for internal ear and bone images) and FC81 (for high resolution images). Effective doses obtained with the D-mode and with the I-mode were about 20% and 50% of those obtained with the MDCT, respectively. Resolution properties obtained with the D-mode and I-mode were superior to that of the MDCT in a high frequency range. Noise properties of the D-mode and the I-mode were better than those with FC81. It was found that the dental CBCT has better potential as compared with MDCT in both dental and implant modes.

  14. Multi-detector row CT as a "one-stop" examination in the preoperative evaluation of the morphology and function of living renal donors: preliminary study.

    PubMed

    Su, Chen; Yan, Chaogui; Guo, Yan; Zhou, Xuhui; Chen, Yaqing; Liu, Mingjuan; Wang, Wenjuan; Zhang, Xiaoling

    2011-02-01

    We designed to investigate the feasibility of multi-detector row computerized tomography (CT) as a "one-stop" examination for the simultaneous preoperative evaluation of the morphology and function of living renal donors. 21 living renal donors were examined by 64-slice spiral CT with a three-phase enhancement CT scan and two inserted dynamic scans. The maximum intensity projection (MIP), multi-planar reformation (MPR), and volume reconstruction (VR) procedures were performed to compare the renal parenchyma, renal vessels, and collecting system with operational findings. The known Patlak equation was used to calculate the glomerular filtration rate (GFR); exact GFR information was acquired by single photon emission computed tomography (SPECT). Our results as following, there were 3 cases of artery variation and 3 cases of vein variation. CT findings all corresponded with the operation, and the sensitivity, positive predictive value, specialty, and negative predictive value of CT were all 100%. The r of the GFR values estimated from CT is 0.894 (left) (P < 0.001) and 0.881 (right) (P < 0.001). In conclusions, our findings demonstrate that 64-slice spiral CT may offer a "one-stop" examination to replace SPECT in the preoperative evaluation of living renal donors to simultaneously provide information regarding both anatomy and the GFR of living renal donors.

  15. Three-dimensional volume-rendered multidetector CT imaging of the posterior inferior pancreaticoduodenal artery: its anatomy and role in diagnosing extrapancreatic perineural invasion

    PubMed Central

    Giacomini, Craig; Brooke Jeffrey, R.; Willmann, Juergen K.; Olcott, Eric

    2013-01-01

    Abstract Extrapancreatic perineural spread in pancreatic adenocarcinoma contributes to poor outcomes, as it is known to be a major contributor to positive surgical margins and disease recurrence. However, current staging classifications have not yet taken extrapancreatic perineural spread into account. Four pathways of extrapancreatic perineural spread have been described that conveniently follow small defined arterial pathways. Small field of view three-dimensional (3D) volume-rendered multidetector computed tomography (MDCT) images allow visualization of small peripancreatic vessels and thus perineural invasion that may be associated with them. One such vessel, the posterior inferior pancreaticoduodenal artery (PIPDA), serves as a surrogate for extrapancreatic perineural spread by pancreatic adenocarcinoma arising in the uncinate process. This pictorial review presents the normal and variant anatomy of the PIPDA with 3D volume-rendered MDCT imaging, and emphasizes its role as a vascular landmark for the diagnosis of extrapancreatic perineural invasion from uncinate adenocarcinomas. Familiarity with the anatomy of PIPDA will allow accurate detection of extrapancreatic perineural spread by pancreatic adenocarcinoma involving the uncinate process, and may potentially have important staging implications as neoadjuvant therapy improves. PMID:24434918

  16. A new 3-D diagnosis strategy for duodenal malignant lesions using multidetector row CT, CT virtual duodenoscopy, duodenography, and 3-D multicholangiography.

    PubMed

    Sata, N; Endo, K; Shimura, K; Koizumi, M; Nagai, H

    2007-01-01

    Recent advances in multidetector row computed tomography (MD-CT) technology provide new opportunities for clinical diagnoses of various diseases. Here we assessed CT virtual duodenoscopy, duodenography, and three-dimensional (3D) multicholangiography created by MD-CT for clinical diagnosis of duodenal malignant lesions. The study involved seven cases of periduodenal carcinoma (four ampullary carcinomas, two duodenal carcinomas, one pancreatic carcinoma). Biliary contrast medium was administered intravenously, followed by intravenous administration of an anticholinergic agent and oral administration of effervescent granules for expanding the upper gastrointestinal tract. Following intravenous administration of a nonionic contrast medium, an upper abdominal MD-CT scan was performed in the left lateral position. Scan data were processed on a workstation to create CT virtual duodenoscopy, duodenography, 3D multicholangiography, and various postprocessing images, which were then evaluated for their effectiveness as preoperative diagnostic tools. Carcinoma location and extent were clearly demonstrated as defects or colored low-density areas in 3-D multicholangiography images and as protruding lesions in virtual duodenography and duodenoscopy images. These findings were confirmed using multiplanar or curved planar reformation images. In conclusion, CT virtual duodenoscopy, doudenography, 3-D multicholangiography, and various images created by MD-CT alone provided necessary and adequate preoperative diagnostic information.

  17. Characterizing string-of-pearls colloidal silica by multidetector hydrodynamic chromatography and comparison to multidetector size-exclusion chromatography, off-line multiangle static light scattering, and transmission electron microscopy.

    PubMed

    Brewer, Amandaa K; Striegel, André M

    2011-04-15

    The string-of-pearls-type morphology is ubiquitous, manifesting itself variously in proteins, vesicles, bacteria, synthetic polymers, and biopolymers. Characterizing the size and shape of analytes with such morphology, however, presents a challenge, due chiefly to the ease with which the "strings" can be broken during chromatographic analysis or to the paucity of information obtained from the benchmark microscopy and off-line light scattering methods. Here, we address this challenge with multidetector hydrodynamic chromatography (HDC), which has the ability to determine, simultaneously, the size, shape, and compactness and their distributions of string-of-pearls samples. We present the quadruple-detector HDC analysis of colloidal string-of-pearls silica, employing static multiangle and quasielastic light scattering, differential viscometry, and differential refractometry as detection methods. The multidetector approach shows a sample that is broadly polydisperse in both molar mass and size, with strings ranging from two to five particles, but which also contains a high concentration of single, unattached "pearls". Synergistic combination of the various size parameters obtained from the multiplicity of detectors employed shows that the strings with higher degrees of polymerization have a shape similar to the theory-predicted shape of a Gaussian random coil chain of nonoverlapping beads, while the strings with lower degrees of polymerization have a prolate ellipsoidal shape. The HDC technique is contrasted experimentally with multidetector size-exclusion chromatography, where, even under extremely gentle conditions, the strings still degraded during analysis. Such degradation is shown to be absent in HDC, as evidenced by the fact that the molar mass and radius of gyration obtained by HDC with multiangle static light scattering detection (HDC/MALS) compare quite favorably to those determined by off-line MALS analysis under otherwise identical conditions. The

  18. Glycybridins A-K, Bioactive Phenolic Compounds from Glycyrrhiza glabra.

    PubMed

    Li, Kai; Ji, Shuai; Song, Wei; Kuang, Yi; Lin, Yan; Tang, Shunan; Cui, Zexu; Qiao, Xue; Yu, Siwang; Ye, Min

    2017-02-24

    In an attempt to discover bioactive agents from the herbal medicine Glycyrrhiza glabra (widely known as licorice), 11 new phenolic compounds, glycybridins A-K (1-11), along with 47 known phenolics (12-58) were isolated. Their structures were elucidated on the basis of extensive NMR and MS analyses as well as experimental and computed ECD data. According to the clinical therapeutic effects of licorice, enzyme or cell-based bioactivity screenings of 1-58 were conducted. A number of compounds significantly activate Nrf2, inhibit tyrosinase or PTP1B, inhibit LPS-induced NO production and NF-κB transcription, and inhibit the proliferation of human cancer cells (HepG2, SW480, A549, MCF7). Glycybridin D (4) showed moderate cytotoxic activities against the four cancer cell lines, with IC50 values ranging from 4.6 to 6.6 μM. Further studies indicated that 4 (10 mg/kg, ip) decreased tumor mass by 39.7% on an A549 human lung carcinoma xenograft mice model, but showed little toxicity.

  19. 76 FR 66178 - Revision of Class E Airspace; Umiat, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-26

    .../rulemaking/ . SUPPLEMENTARY INFORMATION: History On Wednesday, August 10, 2011, the FAA published a notice of... arspace extending upward from 700 feet or more above the surface of the earth. * * * * * AAL AK E5...

  20. 75 FR 12677 - Establishment of Class E Airspace; Shaktoolik, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    .../rulemaking/ . SUPPLEMENTARY INFORMATION: History On Wednesday, December 16, 2009, the FAA published a notice... Extending Upward From 700 Feet or More Above the Surface of the Earth. * * * * * AAL AK E5 Shaktoolik,...

  1. 75 FR 62459 - Revision of Class E Airspace; Unalakleet, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... INFORMATION: History On Thursday, June 10, 2010, the FAA published a notice of proposed rulemaking in the... Extending Upward From 700 Feet or More Above the Surface of the Earth. * * * * * AAL AK E5 Unalakleet,...

  2. 78 FR 5128 - Amendment of Class E Airspace; Savoonga, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-24

    ... Lind Avenue SW., Renton, WA 98057; telephone (425) 203-4517. SUPPLEMENTARY INFORMATION: History On... extending upward from 700 feet or more above the surface of the earth. * * * * * AAL AK E5 Savoonga,...

  3. 75 FR 3641 - Television Broadcasting Services; Anchorage, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-22

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 73 Television Broadcasting Services; Anchorage, AK AGENCY: Federal Communications... broadcasting. 0 For the reasons discussed in the preamble, the Federal Communications Commission amends 47...

  4. RadNet Air Data From Juneau, AK

    EPA Pesticide Factsheets

    This page presents radiation air monitoring and air filter analysis data for Juneau, AK from EPA's RadNet system. RadNet is a nationwide network of monitoring stations that measure radiation in air, drinking water and precipitation.

  5. RadNet Air Data From Anchorage, AK

    EPA Pesticide Factsheets

    This page presents radiation air monitoring and air filter analysis data for Anchorage, AK from EPA's RadNet system. RadNet is a nationwide network of monitoring stations that measure radiation in air, drinking water and precipitation.

  6. Multidetector CT appearance of the pelvis after cesarean delivery: normal and abnormal acute findings.

    PubMed

    Gui, Benedetta; Danza, Francesco Maria; Valentini, Anna Lia; Laino, Maria Elena; Caruso, Alessandro; Carducci, Brigida; Rodolfino, Elena; Devicienti, Ersilia; Bonomo, Lorenzo

    2016-01-01

    Cesarean section (CS) may have several acute complications that can occur in the early postoperative period. The most common acute complications are hematomas and hemorrhage, infection, ovarian vein thrombosis, uterine dehiscence and rupture. Pelvic hematomas usually occur at specific sites and include bladder flap hematoma (between the lower uterine segment and the bladder) and subfascial or rectus sheath hematoma (rectus sheath or prevescical space). Puerperal hemorrhage can be associated with uterine dehiscence or rupture. Pelvic infections include endometritis, abscess, wound infection, and retained product of conception. Radiologists play an important role in the diagnosis and management of postoperative complications as a result of increasing use of multidetector CT in emergency room. The knowledge of normal and abnormal postsurgical anatomy and findings should facilitate the correct diagnosis so that the best management can be chosen for the patient, avoiding unnecessary surgical interventions and additional treatments. In this article we review the surgical cesarean technique and imaging CT technique followed by description of normal and abnormal post-CS CT findings.

  7. Multidetector CT appearance of the pelvis after cesarean delivery: normal and abnormal acute findings

    PubMed Central

    Gui, Benedetta; Danza, Francesco Maria; Valentini, Anna Lia; Laino, Maria Elena; Caruso, Alessandro; Carducci, Brigida; Rodolfino, Elena; Devicienti, Ersilia; Bonomo, Lorenzo

    2016-01-01

    Cesarean section (CS) may have several acute complications that can occur in the early postoperative period. The most common acute complications are hematomas and hemorrhage, infection, ovarian vein thrombosis, uterine dehiscence and rupture. Pelvic hematomas usually occur at specific sites and include bladder flap hematoma (between the lower uterine segment and the bladder) and subfascial or rectus sheath hematoma (rectus sheath or prevescical space). Puerperal hemorrhage can be associated with uterine dehiscence or rupture. Pelvic infections include endometritis, abscess, wound infection, and retained product of conception. Radiologists play an important role in the diagnosis and management of postoperative complications as a result of increasing use of multidetector CT in emergency room. The knowledge of normal and abnormal postsurgical anatomy and findings should facilitate the correct diagnosis so that the best management can be chosen for the patient, avoiding unnecessary surgical interventions and additional treatments. In this article we review the surgical cesarean technique and imaging CT technique followed by description of normal and abnormal post-CS CT findings. PMID:27756714

  8. Revamping AK-Ashland gas cleaning system

    SciTech Connect

    Brandes, H.; Koerbel, R.; Haberkamp, K.; Keeton, S.

    1995-07-01

    AK Steel`s (formerly Armco) BOF shop was using a static precipitator for the primary collection. The system was designed for full combustion in the gas collecting hoods. No secondary dust collection was in place. A detailed study on alternative solutions led to a completely different system in 1990, and an order was awarded to Mannesmann Demag Corp. (MDC) in Dec. 1990. The new gas collection system is using suppressed combustion with the capability to collect Co at a later stage. The gas cleaning uses the Mannesmann Demag Baumco scrubber with a venturi throat for gas flow control. All auxiliary components, water treatment plant, electric substations and sludge handling were designed and supplied by MDC. The secondary dust collection covers the hot metal and scrap charging into the BOF`s, reladling, desulfurization and deslagging by a pulse jet baghouse. All emission limits set by the EPA and guaranteed by MDC have been met by the systems installed.

  9. 76 FR 54152 - Proposed Amendment of Class E Airspace Galbraith Lake, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ...: This action proposes to amend Class E airspace at Galbraith Lake AK. The creation of two special... Class E5 airspace at the Galbraith Lake Airport in Galbraith Lake, AK, to accommodate the creation...

  10. 76 FR 49388 - Proposed Establishment of Class E Airspace; Tatitlek, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-10

    ...: This action proposes to establish Class E airspace at Tatitlek, AK. The creation of a standard... establishing Class E5 airspace at the Tatitlek Airport in Tatitlek, AK, to accommodate the creation of the...

  11. 75 FR 62457 - Establishment of Class E Airspace; Port Clarence, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... INFORMATION: History On Thursday, June 17, 2010, the FAA published a notice of proposed rulemaking in the... or More Above the Surface of the Earth. * * * * * AAL AK E5 Port Clarence, AK Port Clarence...

  12. 75 FR 52368 - Notice of Inventory Completion: Homer Society of Natural History, Pratt Museum, Homer, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-25

    ... Completion: Homer Society of Natural History, Pratt Museum, Homer, AK AGENCY: National Park Service, Interior... of the Homer Society of Natural History, Pratt Museum, Homer, AK. The human remains were removed...

  13. 75 FR 34624 - Revocation of Class D and E Airspace; Big Delta, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ... TRANSPORTATION Federal Aviation Administration 14 CFR Part 71 Revocation of Class D and E Airspace; Big Delta, AK... Class D and E airspace at Big Delta, AK, to eliminate duplicated controlled airspace serving Allen Army... airspace at Big Delta, AK (75 FR 17322). Controlled airspace serving Allen Army Airfield was revised...

  14. 75 FR 32652 - Revocation and Establishment of Class E Airspace; Nuiqsut, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-09

    ..., both formerly known as Oooguruk Drill Site and Oooguruk Tie-in Helipads, respectively. The FAA is... Drill Site Helipad'' and ``Oooguruk Tie-in Helipad''. Subsequent to publication, the FAA gained further... surface of the earth. * * * * * ] AAL AK E5 Oooguruk Drill Site Helipad, AK * * * * * AAL AK E5...

  15. 76 FR 21832 - Proposed Revision of Class E Airspace; Yakutat, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-19

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Revision of Class E Airspace; Yakutat, AK AGENCY... action proposes to revise Class E airspace at Yakutat, AK. The revision of eight Standard Instrument... Administration, 222 West 7th Avenue, Box 14, Anchorage, AK 99513-7587. FOR FURTHER INFORMATION CONTACT:...

  16. Bronchial anatomy of left lung: a study of multi-detector row CT.

    PubMed

    Zhao, Xinya; Ju, Yuanrong; Liu, Cheng; Li, Jianfeng; Huang, Min; Sun, Jian; Wang, Tao

    2009-02-01

    Familiarity with prevailing pattern and variations in the bronchial tree is not only essential for the anatomist to explain bronchial variation in bronchial specimens, but also useful for guiding bronchoscopy and instructing pulmonary segmental resection. The purpose of this study was designed to demonstrate various branching patterns of left lung with 3D images, with special attention given to identify the major types at transverse thin-section CT. Two hundred and sixteen patients with routine thorax scans were enrolled. The images of bronchial tree, virtual bronchoscopy were reconstructed using post-processing technique of multi-detector row CT. We attempted to classify the segmental bronchi by interpreting the post-processing images, and identified them in transverse thin-section CT. Our results showed that the segmental bronchial ramifications of the left superior lobe were classified into three types mainly, i.e., common stem of apical and posterior segmental bronchi (64%, 138/216); trifurcation (23%, 50/216); common stem of apical and anterior segmental bronchi (10%, 22/216), and they could be identified at two typical sections of transverse thin-section CT. There were two major types in left basal segmental bronchi, i.e., bifurcation (75%, 163/216), trifurcation (18%, 39/216), and they could also be identified at two typical sections of transverse thin-section CT. In conclusion, our study have offered simplified branching patterns of bronchi and demonstrated various unusual bronchial branching patterns perfectly with 3D images, and have also revealed how to identify the main branching patterns in transverse thin-section CT.

  17. A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

    SciTech Connect

    Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas; Papadakis, Antonios E.

    2010-12-15

    Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made

  18. Multidetector-row CT with a 64-row amorphous silicon flat panel detector

    NASA Astrophysics Data System (ADS)

    Shapiro, Edward G.; Colbeth, Richard E.; Daley, Earl T.; Job, Isaias D.; Mollov, Ivan P.; Mollov, Todor I.; Pavkovich, John M.; Roos, Pieter G.; Star-Lack, Josh M.; Tognina, Carlo A.

    2007-03-01

    A unique 64-row flat panel (FP) detector has been developed for sub-second multidetector-row CT (MDCT). The intent was to explore the image quality achievable with relatively inexpensive amorphous silicon (a-Si) compared to existing diagnostic scanners with discrete crystalline diode detectors. The FP MDCT system is a bench-top design that consists of three FP modules. Each module uses a 30 cm x 3.3 cm a-Si array with 576 x 64 photodiodes. The photodiodes are 0.52 mm x 0.52 mm, which allows for about twice the spatial resolution of most commercial MDCT scanners. The modules are arranged in an overlapping geometry, which is sufficient to provide a full-fan 48 cm diameter scan. Scans were obtained with various detachable scintillators, e.g. ceramic Gd IIO IIS, particle-in-binder Gd IIO IIS:Tb and columnar CsI:Tl. Scan quality was evaluated with a Catphan-500 performance phantom and anthropomorphic phantoms. The FP MDCT scans demonstrate nearly equivalent performance scans to a commercial 16-slice MDCT scanner at comparable 10 - 20 mGy/100mAs doses. Thus far, a high contrast resolution of 15 lp/cm and a low contrast resolution of 5 mm @ 0.3 % have been achieved on 1 second scans. Sub-second scans have been achieved with partial rotations. Since the future direction of MDCT appears to be in acquiring single organ coverage per scan, future efforts are planned for increasing the number of detector rows beyond the current 64- rows.

  19. Consideration of the Pathological Features of Pediatric Congenital Heart Diseases Which Are Ideally Suitable for Diagnosing With Multidetector-row CT

    PubMed Central

    Hayabuchi, Yasunobu; Inoue, Miki; Watanabe, Noriko; Sakata, Miho; Ohnishi, Tatsuya; Kagami, Shoji

    2011-01-01

    Background A lots of articles published regarding the usefulness of multidetector-row computed tomography (MDCT) in children with congenital heart disease (CHD) mostly describe that it can be an alternative to the invasive catheterization and angiography. The unique diagnostic features of this imaging modality have been largely ignored or disregarded. We described the pathological conditions that cannot be diagnosed by conventional angiography with cardiac catheterization but can be accurately diagnosed by MDCT. Methods We retrospectively reviewed non-ECG-gated MDCT images acquired from 452 children and young adults with CHD between 2005 and 2010 in our institute. In this article, we focused on the diagnostic advantages of MDCT, and indicated five pathological conditions. (1) When Blalock-Taussig shunt total occlusion prevents catheter insertion into the artificial vessel and angiography is ruled out, the peripheral pulmonary artery during the peripheral pulmonary artery can be imaged and diagnosed using MDCT based on blood flow supplied from many small collateral vessels originating from the aorta. (2) The location and protrusion of the device in the vessel after coil embolization to treat patent ductus arteriosus can be accurately visualized by virtual endoscopy using MDCT. (3) Calcification of patches, synthetic blood vessels, and other prostheses that is indistinct on conventional angiograms is clear on MDCT. (4) Simultaneous MDCT observations of the anatomical relationships between arterial and venous systems on the same image can clarify the detail diagnosis for surgical treatment. (5) Compression of the airways by the great vessels and pulmonary segmental emphysematous change can be diagnosed by MDCT. Results and Conclusions Among patients with CHD, MDCT is useful not only as a non-invasive alternative to conventional angiography, but also as a tool for specific morphological diagnoses. In the future, it will be necessary to accumulate experience in the

  20. Assessment of trabecular bone structure of the calcaneus using multi-detector CT: correlation with microCT and biomechanical testing.

    PubMed

    Diederichs, Gerd; Link, Thomas M; Kentenich, Marie; Schwieger, Karsten; Huber, Markus B; Burghardt, Andrew J; Majumdar, Sharmila; Rogalla, Patrik; Issever, Ahi S

    2009-05-01

    The prediction of bone strength can be improved when determining bone mineral density (BMD) in combination with measures of trabecular microarchitecture. The goal of this study was to assess parameters of trabecular bone structure and texture of the calcaneus by clinical multi-detector row computed tomography (MDCT) in an experimental in situ setup and to correlate these parameters with microCT (microCT) and biomechanical testing. Thirty calcanei in 15 intact cadavers were scanned using three different protocols on a 64-slice MDCT scanner with an in-plane pixel size of 208 microm and 500 microm slice thickness. Bone cores were harvested from each specimen and microCT images with a voxel size of 16 microm were obtained. After image coregistration, trabecular bone structure and texture were evaluated in identical regions on the MDCT images. After data acquisition, uniaxial compression testing was performed. Significant correlations between MDCT- and microCT-derived measures of bone volume fraction (BV/TV), trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) were found (range, R(2)=0.19-0.65, p<0.01 or 0.05). The MDCT-derived parameters of volumetric BMD, app. BV/TV, app. Tb.Th and app. Tb.Sp were capable of predicting 60%, 63%, 53% and 25% of the variation in bone strength (p<0.01). When combining those measures with one additional texture index (either GLCM, TOGLCM or MF.euler), prediction of mechanical competence was significantly improved to 86%, 85%, 71% and 63% (p<0.01). In conclusion, this study showed the feasibility of trabecular microarchitecture assessment using MDCT in an experimental setup simulating the clinical situation. Multivariate models of BMD or structural parameters combined with texture indices improved prediction of bone strength significantly and might provide more reliable estimates of fracture risk in patients.

  1. Assessment of organ absorbed doses and estimation of effective doses from pediatric anthropomorphic phantom measurements for multi-detector row CT with and without automatic exposure control.

    PubMed

    Brisse, Hervé J; Robilliard, Magalie; Savignoni, Alexia; Pierrat, Noelle; Gaboriaud, Geneviève; De Rycke, Yann; Neuenschwander, Sylvia; Aubert, Bernard; Rosenwald, Jean-Claude

    2009-10-01

    This study was designed to measure organ absorbed doses from multi-detector row computed tomography (MDCT) on pediatric anthropomorphic phantoms, calculate the corresponding effective doses, and assess the influence of automatic exposure control (AEC) in terms of organ dose variations. Four anthropomorphic phantoms (phantoms represent the equivalent of a newborn, 1-, 5-, and 10-y-old child) were scanned with a four-channel MDCT coupled with a z-axis-based AEC system. Two CT torso protocols were compared: a first protocol without AEC and constant tube current-time product and a second protocol with AEC using age-adjusted noise indices. Organ absorbed doses were monitored by thermoluminescent dosimeters (LiF: Mg, Cu, P). Effective doses were calculated according to the tissue weighting factors of the International Commission on Radiological Protection (). For fixed mA acquisitions, organ doses normalized to the volume CT dose index in a 16-cm head phantom (CTDIvol16) ranged from 0.6 to 1.5 and effective doses ranged from 8.4 to 13.5 mSv. For the newborn-equivalent phantom, the AEC-modulated scan showed almost no significant dose variation compared to the fixed mA scan. For the 1-, 5- and 10-y equivalent phantoms, the use of AEC induced a significant dose decrease on chest organs (ranging from 61 to 31% for thyroid, 37 to 21% for lung, 34 to 17% for esophagus, and 39 to 10% for breast). However, AEC also induced a significant dose increase (ranging from 28 to 48% for salivary glands, 22 to 51% for bladder, and 24 to 70% for ovaries) related to the high density of skull base and pelvic bones. These dose increases should be considered before using AEC as a dose optimization tool in children.

  2. Association of Neutrophil-to-Lymphocyte Ratio with the Severity and Morphology of Coronary Atherosclerotic Plaques Detected by Multidetector Computerized Tomography

    PubMed Central

    Ateş, Ahmet Hakan; Aytemir, Kudret; Koçyiğit, Duygu; Yalcin, Muhammed Ulvi; Gürses, Kadri Murat; Yorgun, Hikmet; Canpolat, Uğur; Hazırolan, Tuncay; Özer, Necla

    2016-01-01

    Background Studies have demonstrated a consistent relationship between white blood cell (WBC) counts and coronary artery disease (CAD). The neutrophil/lymphocyte ratio (NLR) has been considered as a potential marker for identifying individuals under risk of CAD and associated events. In this study, we aimed to evaluate whether NLR was associated with the severity and morphology of coronary atherosclerotic plaques shown by multidetector computed tomography (MDCT). Methods Our study population consisted of 684 patients who underwent dual-source 64 slice MDCT for the assessment of CAD. Coronary arteries were evaluated on a 16-segment basis and critical coronary plaque was described as luminal narrowing > 50%, whereas plaque morphology was assessed on a per segment basis. Total WBC, neutrophil and lymphocyte counts were determined using commercially available assay kits. Results WBC count [7700 (6400-8800) vs. 6800 (5700-7900), p < 0.05] and NLR [2.40 (1.98-3.07) vs. 1.86 (1.50-2.38), p < 0.001] were found to be higher in patients with critical stenosis than in those without. In the binary logistic regression analysis, NLR was a predictor of critical stenosis (odds ratio, 1.68; 95% confidence interval, 1.39-2.03, p < 0.001). NLR levels differed among plaque morphology subtypes (p < 0.05) and was significantly higher in non-calcified plaque (NCP) compared to mixed plaque (MP) and calcified plaque (CP) (p < 0.05). In the multinomial logistic regression analysis, NLR was found to be an independent predictor of NCP, MP and CP (p < 0.001). Conclusions These data show that NLR is associated with both the severity and morphology of coronary atherosclerotic disease. PMID:27899854

  3. An ancient Roman bowl embedded in a soil sample: surface shaded three dimensional display using data from a multi-detector CT.

    PubMed

    De Maeseneer, M; Buls, N; Cleeren, N; Lenchik, L; De Mey, J

    2006-01-01

    We present an unusual application of multidetector CT and shaded surface rendering in the investigation of a soil sample, containing an ancient Roman bronze bowl. The CT findings were of fundamental importance in helping the archaeologists study the bronze bowl from the soil sample.

  4. Hypothenar hammer syndrome in a computer programmer: CTA diagnosis and surgical and endovascular treatment.

    PubMed

    Abdel-Gawad, Ehab A; Bonatti, Hugo; Housseini, Ahmed M; Maged, Ismaeel M; Morgan, Raymond F; Hagspiel, Klaus D

    2009-01-01

    Finger ischemia due to embolic occlusion of digital arteries resulting from trauma to the palmar ulnar artery has been termed hypothenar hammer syndrome (HHS). In HHS, arterial thrombosis and/or aneurysm formation with embolization to the digital arteries causes symptoms of ischemia. We describe a patient in whom the initial diagnosis was made on multidetector computed tomographic angiography (CTA), as well as his endovascular and surgical management.

  5. [Gastrointestinal tract volvulus: diagnosis and correlation between plain-film X-ray and multidetector computed tomography findings].

    PubMed

    Ibáñez Sanz, L; Borruel Nacenta, S; Cano Alonso, R; Díez Martínez, P; Navallas Irujo, M

    2015-01-01

    Gastrointestinal volvuli cause processes that manifest as acute abdomen. Volvuli are important not because they are common, but rather because their possible complications can be severe. All types of volvuli share a common pathophysiology, which consists of intestinal obstruction in a closed loop that results in ischemia. The clinical manifestations are nonspecific, so radiologists play a very important role in the early identification of the most common signs of torsion. These include the "bird's beak sign", the "whirlpool sign", and signs of potentially reversible or irreversible ischemia. The treatment of choice in most cases is surgery, either to correct the torsion and save the organ or to resect it if it is necrotic.

  6. Support vector machine model for diagnosis of lymph node metastasis in gastric cancer with multidetector computed tomography: a preliminary study

    PubMed Central

    2011-01-01

    Background Lymph node metastasis (LNM) of gastric cancer is an important prognostic factor regarding long-term survival. But several imaging techniques which are commonly used in stomach cannot satisfactorily assess the gastric cancer lymph node status. They can not achieve both high sensitivity and specificity. As a kind of machine-learning methods, Support Vector Machine has the potential to solve this complex issue. Methods The institutional review board approved this retrospective study. 175 consecutive patients with gastric cancer who underwent MDCT before surgery were included. We evaluated the tumor and lymph node indicators on CT images including serosal invasion, tumor classification, tumor maximum diameter, number of lymph nodes, maximum lymph node size and lymph nodes station, which reflected the biological behavior of gastric cancer. Univariate analysis was used to analyze the relationship between the six image indicators with LNM. A SVM model was built with these indicators above as input index. The output index was that lymph node metastasis of the patient was positive or negative. It was confirmed by the surgery and histopathology. A standard machine-learning technique called k-fold cross-validation (5-fold in our study) was used to train and test SVM models. We evaluated the diagnostic capability of the SVM models in lymph node metastasis with the receiver operating characteristic (ROC) curves. And the radiologist classified the lymph node metastasis of patients by using maximum lymph node size on CT images as criterion. We compared the areas under ROC curves (AUC) of the radiologist and SVM models. Results In 175 cases, the cases of lymph node metastasis were 134 and 41 cases were not. The six image indicators all had statistically significant differences between the LNM negative and positive groups. The means of the sensitivity, specificity and AUC of SVM models with 5-fold cross-validation were 88.5%, 78.5% and 0.876, respectively. While the diagnostic power of the radiologist classifying lymph node metastasis by maximum lymph node size were only 63.4%, 75.6% and 0.757. Each SVM model of the 5-fold cross-validation performed significantly better than the radiologist. Conclusions Based on biological behavior information of gastric cancer on MDCT images, SVM model can help diagnose the lymph node metastasis preoperatively. PMID:21223564

  7. 75 FR 29582 - Yukon Flats National Wildlife Refuge, Fairbanks, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ...] [FR Doc No: 2010-12629] DEPARTMENT OF THE INTERIOR Fish and Wildlife Service [FWS-R7-R-2010-N082; 70133-1265-0000-U4] Yukon Flats National Wildlife Refuge, Fairbanks, AK AGENCY: U.S. Fish and Wildlife... Wildlife Service (Service), announce the availability of the record of decision (ROD) for the...

  8. 75 FR 76294 - Radio Broadcasting Services; Fairbanks, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-08

    ... COMMISSION 47 CFR Part 73 Radio Broadcasting Services; Fairbanks, AK AGENCY: Federal Communications... Review Act, see U.S.C. 801(a)(1)(A). List of Subjects in 47 CFR Part 73 Radio, Radio broadcasting. 0 For... follows: PART 73--RADIO BROADCAST SERVICES 0 1. The authority citation for Part 73 continues to read...

  9. 78 FR 4586 - Environmental Impact Statement: Kake Access, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-22

    ... Federal Highway Administration Environmental Impact Statement: Kake Access, AK ACTION: Notice of intent... issuing this notice to advise the public that FHWA will prepare an Environmental Impact Statement (EIS... Meetings will be held in the early Spring of 2013 to receive oral and written comments on...

  10. Ak-Chin Indian Community Biomass Feasiiblity Study

    SciTech Connect

    Mark A. Moser, RCM Digesters, Inc.; Mark Randall, Daystar Consulting, LLC; Leonard S. Gold, Ak-Chin Energy Services & Utility Strategies Consulting Group

    2005-12-31

    Study of the conversion of chicken litter to biogas for the production of energy. There was an additional requirement that after extracting the energy from the chicken litter the nutrient value of the raw chicken litter had to be returned to the Ak-Chin Farms for use as fertilizer in a form and delivery method acceptable to the Farm.

  11. 76 FR 8624 - Revision of Class E Airspace; Barrow, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    ... Federal Aviation Administration 14 CFR Part 71 Revision of Class E Airspace; Barrow, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action revises Class E airspace at...) 271-2850; e- mail: Martha.ctr.Dunn@faa.gov . Internet address:...

  12. 78 FR 45849 - Amendment of Class E Airspace; Gustavus, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-30

    ... Federal Aviation Administration 14 CFR Part 71 Amendment of Class E Airspace; Gustavus, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action amends Class E airspace at... the proposal to the FAA. No comments were received. Class E airspace designations are published...

  13. 76 FR 8625 - Revision of Class E Airspace; Savoonga, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    ... Federal Aviation Administration 14 CFR Part 71 Revision of Class E Airspace; Savoonga, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action revises Class E airspace at...-5898; fax: (907) 271-2850; e-mail: martha.ctr.dunn@faa.gov . Internet address:...

  14. The role of multidetector-row CT in the diagnosis, classification and management of acute aortic syndrome

    PubMed Central

    Brown, I W; Peebles, C R; Harden, S P; Shambrook, J S

    2014-01-01

    The term “acute aortic syndrome” (AAS) encompasses several non-traumatic life-threatening pathologies of the thoracic aorta presenting in patients with a similar clinical profile. These include aortic dissection, intramural haematoma and penetrating atherosclerotic ulcers. These different pathological entities can be indistinguishable on clinical grounds alone and may be confused with other causes of chest pain, including myocardial infarction. Multidetector-row CT (MDCT) is the current modality of choice for imaging AAS with a sensitivity and specificity approaching 100%. Early diagnosis and accurate radiological classification is associated with improved clinical outcomes in AAS. We review the characteristic radiological features of the different pathologies that encompass AAS and highlight the vital role of MDCT in determining the management of these life-threatening conditions. PMID:25083552

  15. 78 FR 14185 - Safety Zone; MODU KULLUK; Kiliuda Bay, Kodiak Island, AK to Captains Bay, Unalaska Island, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-05

    ... seabed, around the Outer Continental Shelf Mobile Offshore Drilling Unit (MODU) KULLUK currently located..., AK. The temporary safety zone will encompass the navigable waters within a 1000 meter radius of the... Notice of Proposed Rulemaking A. Regulatory History and Information The Coast Guard is issuing...

  16. 39. View of checkout indicator computer console for DR beams, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. View of checkout indicator computer console for DR beams, TR chains, and special checkout target control located in CSMR in transmitter building no. 102. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  17. H2A/K pseudogene mutation may promote cell proliferation.

    PubMed

    Guo, Jisheng; Jing, Ruirui; Lv, Xin; Wang, Xiaoyue; Li, Junqiang; Li, Lin; Li, Cuiling; Wang, Daoguang; Bi, Baibing; Chen, Xinjun; Yang, Jing-Hua

    2016-05-01

    Little attention has been paid to the histone H2A/K pseudogene. Results from our laboratory showed that 7 of 10 kidney cancer patients carried a mutant H2A/K pseudogene; therefore, we were interested in determining the relationship between mutant H2A/K and cell proliferation. We used shotgun and label-free proteomics methods to study whether mutant H2A/K lncRNAs affected cell proliferation. Quantitative proteomic analysis indicated that the expression of mutant H2A/K lncRNAs resulted in the upregulation of many oncogenes, which promoted cell proliferation. Further interaction analyses revealed that a proliferating cell nuclear antigen (PCNA)-protein interaction network, with PCNA in the center, contributes to cell proliferation in cells expressing the mutant H2A/K lncRNAs. Western blotting confirmed the critical upregulation of PCNA by mutant H2A/K lncRNA expression. Finally, the promotion of cell proliferation by mutant H2A/K lncRNAs (C290T, C228A and A45G) was confirmed using cell proliferation assays. Although we did not determine the exact mechanism by which the oncogenes were upregulated by the mutant H2A/K lncRNAs, we confirmed that the mutant H2A/K lncRNAs promoted cell proliferation by upregulating PCNA and other oncogenes. The hypothesis that cell proliferation is promoted by the mutant H2A/K lncRNAs was supported by the protein expression and cell proliferation assay results. Therefore, mutant H2A/K lncRNAs may be a new factor in renal carcinogenesis.

  18. Immunolocalization of arginine kinase (AK) in Toxocara canis, Toxocara vitulorum, and Ascaris lumbricoides.

    PubMed

    Kulathunga, D G R S; Wickramasinghe, Susiji; Rajapakse, R P V J; Yatawara, Lalani; Jayaweera, W R; Agatsuma, Takeshi

    2012-08-01

    Arginine kinase (AK) is a member of the phosphagen kinase family. AK plays a major role in cellular energy metabolism in invertebrates including nematodes. In the present study, we performed the direct immunofluorescence test to determine the immunolocalization of AK in different stages of the life cycle (eggs, larvae, and adult worms) of Toxocara canis, Toxocara vitulorum, and Ascaris lumbricoides. Our results indicated variable levels of expression of AK in different stages. Moreover, strong fluorescence was observed in cleaving eggs than in dormant eggs. The highest activity of the enzyme was observed in the fully developed eggs. This may be due to high expression of AK in embryonic development, which is associated with increased energy demand due to cleavage and cellular differentiation. Surprisingly, expression of AK is significantly higher in the middle part and posterior end compared to anterior end of the larvae. In addition, AK is highly concentrated in cellular and metabolically active parts of the body such as hypodermis, muscle, intestine, ovaries, oviducts, and uterus, while it is absent in noncellular areas like cuticle. The present study revealed the presence of AK in T. canis, A. lumbricoides, and T. vitulorum and that it plays a major role in energy metabolism of these nematodes. Interestingly, antiserum was prepared against the recombinant T. canis AK and reacts with the native AKs of T. canis, A. lumbricoides, and T. vitulorum. AK levels could vary in relation to maximum potential rates of ATP turnover, oxidative capacity, and energy output. Further studies on subcellular localization of AK in these important helminths provide new information for researchers to develop effective anthelmintics against the parasites of veterinary and of public health importance.

  19. Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose.

    PubMed

    DeMarco, J J; Cagnon, C H; Cody, D D; Stevens, D M; McCollough, C H; Zankl, M; Angel, E; McNitt-Gray, M F

    2007-05-07

    The purpose of this work is to examine the effects of patient size on radiation dose from CT scans. To perform these investigations, we used Monte Carlo simulation methods with detailed models of both patients and multidetector computed tomography (MDCT) scanners. A family of three-dimensional, voxelized patient models previously developed and validated by the GSF was implemented as input files using the Monte Carlo code MCNPX. These patient models represent a range of patient sizes and ages (8 weeks to 48 years) and have all radiosensitive organs previously identified and segmented, allowing the estimation of dose to any individual organ and calculation of patient effective dose. To estimate radiation dose, every voxel in each patient model was assigned both a specific organ index number and an elemental composition and mass density. Simulated CT scans of each voxelized patient model were performed using a previously developed MDCT source model that includes scanner specific spectra, including bowtie filter, scanner geometry and helical source path. The scan simulations in this work include a whole-body scan protocol and a thoracic CT scan protocol, each performed with fixed tube current. The whole-body scan simulation yielded a predictable decrease in effective dose as a function of increasing patient weight. Results from analysis of individual organs demonstrated similar trends, but with some individual variations. A comparison with a conventional dose estimation method using the ImPACT spreadsheet yielded an effective dose of 0.14 mSv mAs(-1) for the whole-body scan. This result is lower than the simulations on the voxelized model designated 'Irene' (0.15 mSv mAs(-1)) and higher than the models 'Donna' and 'Golem' (0.12 mSv mAs(-1)). For the thoracic scan protocol, the ImPACT spreadsheet estimates an effective dose of 0.037 mSv mAs(-1), which falls between the calculated values for Irene (0.042 mSv mAs(-1)) and Donna (0.031 mSv mAs(-1)) and is higher relative

  20. Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction

    SciTech Connect

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John

    2007-07-15

    The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary study on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM

  1. Improving Image Quality of On-Board Cone-Beam CT in Radiation Therapy Using Image Information Provided by Planning Multi-Detector CT: A Phantom Study

    PubMed Central

    Yang, Ching-Ching; Chen, Fong-Lin; Lo, Yeh-Chi

    2016-01-01

    Purpose The aim of this study was to improve the image quality of cone-beam computed tomography (CBCT) mounted on the gantry of a linear accelerator used in radiation therapy based on the image information provided by planning multi-detector CT (MDCT). Methods MDCT-based shading correction for CBCT and virtual monochromatic CT (VMCT) synthesized using the dual-energy method were performed. In VMCT, the high-energy data were obtained from CBCT, while the low-energy data were obtained from MDCT. An electron density phantom was used to investigate the efficacy of shading correction and VMCT on improving the target detectability, Hounsfield unit (HU) accuracy and variation, which were quantified by calculating the contrast-to-noise ratio (CNR), the percent difference (%Diff) and the standard deviation of the CT numbers for tissue equivalent background material, respectively. Treatment plan studies for a chest phantom were conducted to investigate the effects of image quality improvement on dose planning. Results For the electron density phantom, the mean value of CNR was 17.84, 26.78 and 34.31 in CBCT, shading-corrected CBCT and VMCT, respectively. The mean value of %Diff was 152.67%, 11.93% and 7.66% in CBCT, shading-corrected CBCT and VMCT, respectively. The standard deviation within a uniform background of CBCT, shading-corrected CBCT and VMCT was 85, 23 and 15 HU, respectively. With regards to the chest phantom, the monitor unit (MU) difference between the treatment plan calculated using MDCT and those based on CBCT, shading corrected CBCT and VMCT was 6.32%, 1.05% and 0.94%, respectively. Conclusions Enhancement of image quality in on-board CBCT can contribute to daily patient setup and adaptive dose delivery, thus enabling higher confidence in patient treatment accuracy in radiation therapy. Based on our results, VMCT has the highest image quality, followed by the shading corrected CBCT and the original CBCT. The research results presented in this study should be

  2. Recovery Act: Waste Energy Project at AK Steel Corporation Middletown

    SciTech Connect

    Joyce, Jeffrey

    2012-06-30

    In 2008, Air Products and Chemicals, Inc. (“Air Products”) began development of a project to beneficially utilize waste blast furnace “topgas” generated in the course of the iron-making process at AK Steel Corporation’s Middletown, Ohio works. In early 2010, Air Products was awarded DOE Assistance Agreement DE-EE002736 to further develop and build the combined-cycle power generation facility. In June 2012, Air Products and AK Steel Corporation terminated work when it was determined that the project would not be economically viable at that time nor in the foreseeable future. The project would have achieved the FOA-0000044 Statement of Project Objectives by demonstrating, at a commercial scale, the technology to capture, treat, and convert blast furnace topgas into electric power and thermal energy.

  3. 75 FR 1077 - Notice of Proposed Withdrawal Extension and Opportunity for Public Meeting; AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-08

    ... [Federal Register Volume 75, Number 5 (Friday, January 8, 2010)] [Notices] [Pages 1077-1078] [FR Doc No: 2010-94] DEPARTMENT OF THE INTERIOR Bureau of Land Management [AK-963-1410-ET; AA-5964, AA-3060, AA-5934] Notice of Proposed Withdrawal Extension and Opportunity for Public Meeting; AK...

  4. 78 FR 59806 - Establishment of Class E Airspace; White Mountain, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-30

    ... Federal Aviation Administration 14 CFR Part 71 Establishment of Class E Airspace; White Mountain, AK... Class E airspace at White Mountain Airport, White Mountain, AK, to accommodate aircraft using new Area... Federal Register a notice of proposed rulemaking (NPRM) to establish controlled airspace at White...

  5. 75 FR 77572 - Proposed Revision of Class E Airspace; Platinum AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Revision of Class E Airspace; Platinum AK AGENCY... action proposes to revise Class E airspace at Platinum AK. The creation of a new Standard Instrument Approach Procedure (SIAP) at the Platinum Airport has made this action necessary to enhance safety...

  6. Reticular dysgenesis–associated AK2 protects hematopoietic stem and progenitor cell development from oxidative stress

    PubMed Central

    Rissone, Alberto; Weinacht, Katja Gabriele; la Marca, Giancarlo; Bishop, Kevin; Giocaliere, Elisa; Jagadeesh, Jayashree; Felgentreff, Kerstin; Dobbs, Kerry; Al-Herz, Waleed; Jones, Marypat; Chandrasekharappa, Settara; Kirby, Martha; Wincovitch, Stephen; Simon, Karen Lyn; Itan, Yuval; DeVine, Alex; Schlaeger, Thorsten; Schambach, Axel; Sood, Raman

    2015-01-01

    Adenylate kinases (AKs) are phosphotransferases that regulate the cellular adenine nucleotide composition and play a critical role in the energy homeostasis of all tissues. The AK2 isoenzyme is expressed in the mitochondrial intermembrane space and is mutated in reticular dysgenesis (RD), a rare form of severe combined immunodeficiency (SCID) in humans. RD is characterized by a maturation arrest in the myeloid and lymphoid lineages, leading to early onset, recurrent, and overwhelming infections. To gain insight into the pathophysiology of RD, we studied the effects of AK2 deficiency using the zebrafish model and induced pluripotent stem cells (iPSCs) derived from fibroblasts of an RD patient. In zebrafish, Ak2 deficiency affected hematopoietic stem and progenitor cell (HSPC) development with increased oxidative stress and apoptosis. AK2-deficient iPSCs recapitulated the characteristic myeloid maturation arrest at the promyelocyte stage and demonstrated an increased AMP/ADP ratio, indicative of an energy-depleted adenine nucleotide profile. Antioxidant treatment rescued the hematopoietic phenotypes in vivo in ak2 mutant zebrafish and restored differentiation of AK2-deficient iPSCs into mature granulocytes. Our results link hematopoietic cell fate in AK2 deficiency to cellular energy depletion and increased oxidative stress. This points to the potential use of antioxidants as a supportive therapeutic modality for patients with RD. PMID:26150473

  7. 76 FR 56354 - Proposed Amendment of Class E Airspace; Anaktuvuk Pass, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-13

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Amendment of Class E Airspace; Anaktuvuk Pass, AK...: This action proposes to revise Class E airspace at Anaktuvuk Pass, AK. The creation of two standard instrument approach procedures at the Anaktuvuk Pass Airport has made this action necessary to enhance...

  8. 76 FR 78144 - Amendment of Class E Airspace; Anaktuvuk Pass, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-16

    ... Federal Aviation Administration 14 CFR Part 71 Amendment of Class E Airspace; Anaktuvuk Pass, AK AGENCY... airspace at Anaktuvuk Pass Airport, Anaktuvuk Pass, AK. The creation of two standard instrument approach... Federal Register a notice of proposed rulemaking (NPRM) to amend controlled airspace at Anaktuvuk Pass,...

  9. Efficient Activation of Apoptotic Signaling during Mitotic Arrest with AK301

    PubMed Central

    Bleiler, Marina; Yeagley, Michelle; Wright, Dennis; Giardina, Charles

    2016-01-01

    Mitotic inhibitors are widely utilized chemotherapeutic agents that take advantage of mitotic defects in cancer cells. We have identified a novel class of piperazine-based mitotic inhibitors, of which AK301 is the most potent derivative identified to date (EC50 < 200 nM). Colon cancer cells arrested in mitosis with AK301 readily underwent a p53-dependent apoptosis following compound withdrawal and arrest release. This apoptotic response was significantly higher for AK301 than for other mitotic inhibitors tested (colchicine, vincristine, and BI 2536). AK301-treated cells exhibited a robust mitosis-associated DNA damage response, including ATM activation, γH2AX phosphorylation and p53 stabilization. The association between mitotic signaling and the DNA damage response was supported by the finding that Aurora B inhibition reduced the level of γH2AX staining. Confocal imaging of AK301-treated cells revealed multiple γ-tubulin microtubule organizing centers attached to microtubules, but with limited centrosome migration, raising the possibility that aberrant microtubule pulling may underlie DNA breakage. AK301 selectively targeted APC-mutant colonocytes and promoted TNF-induced apoptosis in p53-mutant colon cancer cells. Our findings indicate that AK301 induces a mitotic arrest state with a highly active DNA damage response. Together with a reversible arrest state, AK301 is a potent promoter of a mitosis-to-apoptosis transition that can target cancer cells with mitotic defects. PMID:27097159

  10. 75 FR 17892 - Proposed Revision of Class E Airspace; Galena, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-08

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Revision of Class E Airspace; Galena, AK AGENCY... action proposes to revise Class E airspace at Galena, AK. The amendment of three Standard Instrument Approach Procedures (SIAPs), and the development of one Obstacle Departure Procedure (ODP) at the Edward...

  11. 75 FR 32865 - Proposed Revision of Class E Airspace; Unalakleet, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Revision of Class E Airspace; Unalakleet, AK...: This action proposes to revise Class E airspace at Unalakleet, AK. The amendment and development of two (each) Standard Instrument Approach Procedures (SIAPs), and the development of one Obstacle...

  12. 75 FR 77574 - Proposed Revision of Class E Airspace; Savoonga, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Revision of Class E Airspace; Savoonga, AK AGENCY... action proposes to revise Class E airspace at Savoonga, AK. The amendment of three Standard Instrument Approach Procedures (SIAPs) plus the creation of one new SIAP at the Savoonga Airport have made this...

  13. 76 FR 3011 - Establishment of Class E Airspace; Port Clarence, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... Federal Aviation Administration 14 CFR Part 71 Establishment of Class E Airspace; Port Clarence, AK AGENCY.... SUMMARY: This action changes the effective date for the establishment of Class E airspace at Port Clarence Coast Guard Station (CGS) Airport, Port Clarence, AK. The charting of this airspace has been...

  14. 75 FR 81110 - Establishment of Class E Airspace; Port Clarence, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-27

    ... Federal Aviation Administration 14 CFR Part 71 Establishment of Class E Airspace; Port Clarence, AK AGENCY... errors in the legal description and airport coordinates for Port Clarence Coast Guard Station (CGS) Airport, Port Clarence, AK, contained in a final rule that was published in the Federal Register....

  15. Some aspects of the effects of PL-10.1.AK-15 on the gastrointestinal tract.

    PubMed

    Erceg, D; Simicevic, V N; Kolega, M; Dohoczky, C

    1997-01-01

    PL-10.1.AK-15 is an active fragment of a naturally occurring protein first isolated from human gastric juice. Among its other protective effects, PL-10.1.AK-15 has demonstrated a protective effect on the gastrointestinal tract. The aim of this study was to investigate the influence of PL-10.1.AK-15 on two functional parameters of gastrointestinal function: gastric acid secretion and gastrointestinal motility. Gastric acid secretion was assessed in male Wistar rats using a modified method of Shay, while gastrointestinal motility was assessed in male NMRI mice by charcoal propulsion. PL-10.1.AK-15 was given in three different doses (3, 10 and 100 micrograms/kg body weight) in accordance with the experimental protocol. The results of these experiments indicate that PL-10.1.AK-15 in the investigated doses had no influence on gastric acid secretion or gastrointestinal motility.

  16. Invited review-Computed tomographic angiography (CTA) of the thoracic cardiovascular system in companion animals.

    PubMed

    Drees, Randi; François, Christopher J; Saunders, Jimmy H

    2014-01-01

    Computed tomographic angiography (CTA) of the thoracic cardiovascular system is offering new diagnostic opportunities in companion animal patients with the increasing availability of multidetector-row computed tomographic (MDCT) units in veterinary facilities. Optimal investigation of the systemic, pulmonary, and coronary circulation provides unique challenges due to the constant movement of the heart, the small size of several of the structures of interest, and the dependence of angiographic quality on various contrast bolus design and patient factors. Technical and practical aspects of thoracic cardiovascular CTA are reviewed in light of the currently available veterinary literature and future opportunities given utilizing MDCT in companion animal patients with suspected thoracic cardiovascular disease.

  17. Computer-Aided Diagnosis of Lung Cancer and Pulmonary Embolism in Computed Tomography — A Review

    PubMed Central

    Chan, Heang-Ping; Hadjiiski, Lubomir; Zhou, Chuan; Sahiner, Berkman

    2009-01-01

    Computer-aided detection (CADe) and computer-aided diagnosis (CADx) have been important areas of research in the last two decades. Significant progresses have been made in the area of breast cancer detection, and CAD techniques are being developed in many other areas. Recent advances in multidetector row CT have made it an increasingly common modality for imaging of lung diseases. A thoracic examination using thin-section CT contains hundreds of images. Detection of lung cancer and pulmonary embolism on CT examinations are demanding tasks for radiologists because they have to search for abnormalities in a large number of images and the lesions can be subtle. If successfully developed, CAD can be a useful second opinion to radiologists in thoracic CT interpretation. In this review, we summarize the studies that have been reported in these areas, discuss some challenges in the development of CAD, and identify areas that deserve particular attention in future research. PMID:18423310

  18. Evaluation of bone substitute materials: comparison of flat-panel based volume CT to conventional multidetector CT.

    PubMed

    Sauerbier, Sebastian; Duttenhoefer, Fabian; Sachlos, Elefterios; Haberstroh, Jörg; Scheifele, Christian; Wrbas, Karl-Thomas; Voss, Pit Jacob; Veigel, Egle; Smedek, Jörg; Ganter, Philip; Tuna, Taskin; Gutwald, Ralf; Palmowski, Moritz

    2013-10-01

    Over the last decade tissue engineering has emerged as a key factor in bone regeneration within the field of cranio-maxillofacial surgery. Despite this in vivo analysis of tissue-engineered-constructs to monitor bone rehabilitation are difficult to conduct. Novel high-resolving flat-panel based volume CTs (fp-VCT) are increasingly used for imaging bone structures. This study compares the potential value of novel fp-VCT with conventional multidetector CT (MDCT) based on a sheep sinus floor elevation model. Calcium-hydroxyapatite reinforced collagen scaffolds were populated with autologous osteoblasts and implanted into sheep maxillary sinus. After 8, 16 and 24 weeks MDCT and fp-VCT scans were performed to investigate the volume of the augmented area; densities of cancellous and compact bone were assessed as comparative values. fp-VCT imaging resulted in higher spatial resolution, which was advantageous when separating closely related anatomical structures (i.e. trabecular and compact bone, biomaterials). Fp-VCT facilitated imaging of alterations occurring in test specimens over time. fp-VCTs therefore displayed high volume coverage, dynamic imaging potential and superior performance when investigating superfine bone structures and bone remodelling of biomaterials. Thus, fp-VCTs may be a suitable instrument for intraoperative imaging and future in vivo tissue-engineering studies.

  19. Diagnostic capability of gadoxetate disodium-enhanced liver MRI for diagnosis of hepatocellular carcinoma: comparison with multi-detector CT.

    PubMed

    Toyota, Naoyuki; Nakamura, Yuko; Hieda, Masashi; Akiyama, Naoko; Terada, Hiroaki; Matsuura, Noriaki; Nishiki, Masayo; Kono, Hirotaka; Kohno, Hiroshi; Irei, Toshimitsu; Yoshikawa, Yukinobu; Kuraoka, Kazuya; Taniyama, Kiyomi; Awai, Kazuo

    2013-09-01

    The purpose of this study was to evaluate the diagnostic capability of gadoxetate disodium (Gd-EOB)-MRI for the detection of hepatocellular carcinoma (HCC) compared with multidetector CT (MDCT). Fifty patients with 57 surgically proven HCCs who underwent Gd-EOB-MRI and MDCT from March 2008 to June 2011 were evaluated. Two observers evaluated MR and CT on a lesion-by-lesion basis. We analyzed sensitivity by grading on a 5-point scale, the degree of arterial enhancement and the differences in histological grades in the diffusion-weighted images (DWI). The results showed that the sensitivity of Gd-EOB-MRI was higher than that of MDCT especially for HCCs that were 1 cm in diameter or smaller. The hepatobiliary phase was useful for the detecting of small HCC. We had few cases in which it was difficult to judge HCC in the arterial enhancement between MRI and MDCT. In the diffusion-weighted image, well differentiated HCC tended to show a low signal intensity, and poorly differentiated HCC tended to show a high signal intensity. In moderately differentiated HCC's, the mean diameter of the high signal intensity group was larger than that of the low signal intensity group (24.5 mm vs. 15.8 mm). In conclusion, Gd-EOB-MRI tended to show higher sensitivity compared to MDCT in the detection of HCC.

  20. Volume Changes of Experimental Carotid Sidewall Aneurysms Due to Embolization with Liquid Embolic Agents: A Multidetector CT Angiography Study

    SciTech Connect

    Dudeck, O. Okuducu, A. F.; Jordan, O.; Tesmer, K.; Pech, M.; Weigang, E.; Ruefenacht, D. A.; Doelker, E.; Felix, R.

    2006-12-15

    Iodine-containing polyvinyl alcohol polymer (I-PVAL) is a novel precipitating liquid embolic that allows for artifact-free evaluation of CT angiography (CTA). As accurate aneurysm volumetry can be performed with multidetector CTA, we determined volumes of experimental aneurysms before, immediately after, and 4 weeks after embolization of 14 porcine experimental carotid sidewall aneurysms with this liquid embolic. An automated three-dimensional software measurement tool was used for volumetric analysis of volume-rendering CTA data. Furthermore, intra-aneurysmal pressure changes during liquid embolization were measured in four silicone aneurysms and potential polymer volume changes within 4 weeks were assessed in vitro. Liquid embolic injection was performed during temporary balloon occlusion of the aneurysm neck, resulting in a mean occlusion rate of 98.3%. Aneurysms enlarged significantly during embolization by 61.1 {+-} 28.9%, whereas a significant shrinkage of 5.6 {+-} 2.7% was observed within the follow-up period. Histologic analysis revealed an inflammatory foreign body reaction with partial polymer degradation. In silicone aneurysm models, intra-aneurysmal pressure remained unchanged during liquid embolic injection, whereas balloon inflation resulted in a mean pressure increase of 31.2 {+-} 0.7%. No polymer shrinkage was observed in vitro. The aneurysm enlargement noted was presumably due to pressure elevation after balloon inflation, which resulted in dilatation of the weak venous wall of the newly constructed aneurysm-another shortcoming of this experimental aneurysm model. The volume decrease after 4 weeks expressed partial polymer degradation.

  1. AK2 deficiency compromises the mitochondrial energy metabolism required for differentiation of human neutrophil and lymphoid lineages

    PubMed Central

    Six, E; Lagresle-Peyrou, C; Susini, S; De Chappedelaine, C; Sigrist, N; Sadek, H; Chouteau, M; Cagnard, N; Fontenay, M; Hermine, O; Chomienne, C; Reynier, P; Fischer, A; André-Schmutz, I; Gueguen, N; Cavazzana, M

    2015-01-01

    Reticular dysgenesis is a human severe combined immunodeficiency that is primarily characterized by profound neutropenia and lymphopenia. The condition is caused by mutations in the adenylate kinase 2 (AK2) gene, resulting in the loss of mitochondrial AK2 protein expression. AK2 regulates the homeostasis of mitochondrial adenine nucleotides (ADP, ATP and AMP) by catalyzing the transfer of high-energy phosphate. Our present results demonstrate that AK2-knocked-down progenitor cells have poor proliferative and survival capacities and are blocked in their differentiation toward lymphoid and granulocyte lineages. We also observed that AK2 deficiency impaired mitochondrial function in general and oxidative phosphorylation in particular – showing that AK2 is critical in the control of energy metabolism. Loss of AK2 disrupts this regulation and leads to a profound block in lymphoid and myeloid cell differentiation. PMID:26270350

  2. Multiforms of mammalian adenylate kinase and its monoclonal antibody against AK1.

    PubMed

    Kurokawa, Y; Takenaka, H; Sumida, M; Oka, K; Hamada, M; Kuby, S A

    1990-01-01

    An attempt has been made to determine the intracellular distribution of the multiforms of the adenylate kinase (AK) isoenzymes in mammalian tissues, to shed some light on their physiological roles, especially in energy metabolism. The adenylate kinase zymograms obtained from isoelectric focusing yielded two typical isoform patterns: (1) with a pI greater than or equal to 9 and 8.6, specific for bovine skeletal muscle, heart, aorta and brain, and (2) with a pI = 7.9 and 7.1, specific for liver and kidney. Pattern (1) was attributed to the cytosolic isoenzyme (AK1) as demonstrated by immunostaining with anti-AK1. Pattern (2) was attributed to the mitochondrial isoenzyme (AK2). These results were largely confirmed by chromatofocusing experiments. The AK1 isoenzyme was partially purified from the cytosol fraction of bovine aortic smooth muscle and had an apparent Mr of 23.5 kilodaltons. Its kinetic features are discussed from a comparative standpoint. Finally, the human serum AK1 isoform was also detected by Western blotting with a monoclonal antibody directed against crystalline porcine muscle AK1. These results are to form the basis of further studies on the 'aberrant' adenylate kinase isoenzyme from the serum of Duchenne muscular dystrophics.

  3. LncRNA AK023948 is a positive regulator of AKT

    PubMed Central

    Koirala, Pratirodh; Huang, Jianguo; Ho, Tsui-Ting; Wu, Fangting; Ding, Xianfeng; Mo, Yin-Yuan

    2017-01-01

    Despite the overwhelming number of human long non-coding RNAs (lncRNAs) reported so far, little is known about their physiological functions for the majority of them. The present study uses a CRISPR/Cas9-based synergistic activation mediator (SAM) system to identify potential lncRNAs capable of regulating AKT activity. Among lncRNAs identified from this screen, we demonstrate that AK023948 is a positive regulator for AKT. Knockout of AK023948 suppresses, whereas rescue with AK023948 restores the AKT activity. Mechanistically, AK023948 functionally interacts with DHX9 and p85. Importantly, AK023948 is required for the interaction between DHX9 and p85 to hence the p85 stability and promote AKT activity. Finally, AK023948 is upregulated in breast cancer; interrogation of TCGA data set indicates that upregulation of DHX9 in breast cancer is associated with poor survival. Together, this study demonstrates two previously uncharacterized factors AK023948 and DHX9 as important players in the AKT pathway, and that their upregulation may contribute to breast tumour progression. PMID:28176758

  4. High Level Expression and Purification of Recombinant Proteins from Escherichia coli with AK-TAG

    PubMed Central

    Luo, Dan; Wen, Caixia; Zhao, Rongchuan; Liu, Xinyu; Liu, Xinxin; Cui, Jingjing; Liang, Joshua G.; Liang, Peng

    2016-01-01

    Adenylate kinase (AK) from Escherichia coli was used as both solubility and affinity tag for recombinant protein production. When fused to the N-terminus of a target protein, an AK fusion protein could be expressed in soluble form and purified to near homogeneity in a single step from Blue-Sepherose via affinity elution with micromolar concentration of P1, P5- di (adenosine—5’) pentaphosphate (Ap5A), a transition-state substrate analog of AK. Unlike any other affinity tags, the level of a recombinant protein expression in soluble form and its yield of recovery during each purification step could be readily assessed by AK enzyme activity in near real time. Coupled to a His-Tag installed at the N-terminus and a thrombin cleavage site at the C terminus of AK, the streamlined method, here we dubbed AK-TAG, could also allow convenient expression and retrieval of a cleaved recombinant protein in high yield and purity via dual affinity purification steps. Thus AK-TAG is a new addition to the arsenal of existing affinity tags for recombinant protein expression and purification, and is particularly useful where soluble expression and high degree of purification are at stake. PMID:27214237

  5. Crossed Fused Renal Ectopia: Presentations on 99mTc-MAG3 Scan, 99mTc-DMSA SPECT, and Multidetector CT.

    PubMed

    Moon, Eun Ha; Kim, Min-Woo; Kim, Young Jun; Sun, In O

    2015-10-01

    Crossed renal ectopia is an uncommon developmental anomaly in which both kidneys are located on the same side of the body. The present case describes a 20-year-old man who underwent the military entrance physical examination. The ultrasound showed the right kidney in normal site with slightly increased size, but the left kidney was not identified. Tc-MAG3 scan showed a single kidney with 2 ureters, and the orifices of the ureters were connected at both sides of bladder. Tc-DMSA SPECT and contrast-enhanced multidetector CT were performed and revealed crossed fused renal ectopia.

  6. Development of a parallel detection and processing system using a multidetector array for wave field restoration in scanning transmission electron microscopy.

    PubMed

    Taya, Masaki; Matsutani, Takaomi; Ikuta, Takashi; Saito, Hidekazu; Ogai, Keiko; Harada, Yoshihito; Tanaka, Takeo; Takai, Yoshizo

    2007-08-01

    A parallel image detection and image processing system for scanning transmission electron microscopy was developed using a multidetector array consisting of a multianode photomultiplier tube arranged in an 8 x 8 square array. The system enables the taking of 64 images simultaneously from different scattered directions with a scanning time of 2.6 s. Using the 64 images, phase and amplitude contrast images of gold particles on an amorphous carbon thin film could be separately reconstructed by applying respective 8 shaped bandpass Fourier filters for each image and multiplying the phase and amplitude reconstructing factors.

  7. Multi-detector CT assessment in pulmonary hypertension: techniques, systematic approach to interpretation and key findings.

    PubMed

    Lewis, Gareth; Hoey, Edward T D; Reynolds, John H; Ganeshan, Arul; Ment, Jerome

    2015-06-01

    Pulmonary arterial hypertension (PAH) may be suspected based on the clinical history, physical examination and electrocardiogram findings but imaging is usually central to confirming the diagnosis, establishing a cause and guiding therapy. The diagnostic pathway of PAH involves a variety of complimentary investigations of which computed tomography pulmonary angiography (CTPA) has established a central role both in helping identify an underlying cause for PAH and assessing resulting functional compromise. In particular CTPA is considered as the gold standard technique for the diagnosis of thromboembolic disease. This article reviews the CTPA evaluation in PAH, describing CTPA techniques, a systematic approach to interpretation and spectrum of key imaging findings.

  8. Hypercortisolism Is Associated With Increased Coronary Arterial Atherosclerosis: Analysis of Noninvasive Coronary Angiography Using Multidetector Computerized Tomography

    PubMed Central

    Neary, Nicola M.; Booker, O. Julian; Abel, Brent S.; Matta, Jatin R.; Muldoon, Nancy; Sinaii, Ninet; Pettigrew, Roderic I.; Nieman, Lynnette K.

    2013-01-01

    Background: Observational studies show that glucocorticoid therapy and the endogenous hypercortisolism of Cushing's syndrome (CS) are associated with increased rates of cardiovascular morbidity and mortality. However, the causes of these findings remain largely unknown. Objective: To determine whether CS patients have increased coronary atherosclerosis. Design: A prospective case-control study was performed. Setting: Subjects were evaulated in a clinical research center. Subjects: Fifteen consecutive patients with ACTH-dependent CS, 14 due to an ectopic source and 1 due to pituitary Cushing's disease were recruited. Eleven patients were studied when hypercortisolemic; 4 patients were eucortisolemic due to medication (3) or cyclic hypercortisolism (1). Fifteen control subjects with at least one risk factor for cardiac disease were matched 1:1 for age, sex, and body mass index. Primary outcome variables: Agatston score a measure of calcified plaque and non-calcified coronary plaque volume were quantified using a multidetector CT (MDCT) coronary angiogram scan. Additional variables included fasting lipids, blood pressure, history of hypertension or diabetes, and 24-hour urine free cortisol excretion. Results: CS patients had significantly greater noncalcified plaque volume and Agatston score (noncalcified plaque volume [mm3] median [interquartile ranges]: CS 49.5 [31.4, 102.5], controls 17.9 [2.6, 25.3], P < .001; Agatston score: CS 70.6 [0, 253.1], controls 0 [0, 7.6]; P < .05). CS patients had higher systolic and diastolic blood pressures than controls (systolic: CS 143 mm Hg [135, 173]; controls, 134 [123, 136], P < .02; diastolic CS: 86 [80, 99], controls, 76 [72, 84], P < .05). Conclusions: Increased coronary calcifications and noncalcified coronary plaque volumes are present in patients with active or previous hypercortisolism. Increased atherosclerosis may contribute to the increased rates of cardiovascular morbidity and mortality in patients with

  9. [Computed tomography and cranial paleoanthropology].

    PubMed

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils.

  10. The Alaska Arctic Vegetation Archive (AVA-AK)

    SciTech Connect

    Walker, Donald; Breen, Amy; Druckenmiller, Lisa; Wirth, Lisa W.; Fisher, Will; Raynolds, Martha K.; Sibik, Jozef; Walker, Marilyn D.; Hennekens, Stephan; Boggs, Keith; Boucher, Tina; Buchhorn, Marcel; Bultmann, Helga; Cooper, David; Daniels, Fred J. A.; Davidson, Scott J.; Ebersole, James J.; Elmendorf, Sara C.; Epstein, Howard E.; Gould, William A.; Hollister, Robert D.; Iversen, Colleen M.; Jorgenson, M. Torre; Kade, Anja; Lee, Michael T.; MacKenzie, William H.; Peet, Robert K.; Peirce, Jana L.; Schickhoff, Udo; Sloan, Victoria L.; Talbot, Stephen S.; Tweedie, Craig E.; Villarreal, Sandra; Webber, Patrick J.; Zona, Donatella

    2016-05-17

    The Alaska Arctic Vegetation Archive (AVA-AK, GIVD-ID: NA-US-014) is a free, publically available database archive of vegetation-plot data from the Arctic tundra region of northern Alaska. The archive currently contains 24 datasets with 3,026 non-overlapping plots. Of these, 74% have geolocation data with 25-m or better precision. Species cover data and header data are stored in a Turboveg database. A standardized Pan Arctic Species List provides a consistent nomenclature for vascular plants, bryophytes, and lichens in the archive. A web-based online Alaska Arctic Geoecological Atlas (AGA-AK) allows viewing and downloading the species data in a variety of formats, and provides access to a wide variety of ancillary data. We conducted a preliminary cluster analysis of the first 16 datasets (1,613 plots) to examine how the spectrum of derived clusters is related to the suite of datasets, habitat types, and environmental gradients. Here, we present the contents of the archive, assess its strengths and weaknesses, and provide three supplementary files that include the data dictionary, a list of habitat types, an overview of the datasets, and details of the cluster analysis.

  11. The Alaska Arctic Vegetation Archive (AVA-AK)

    DOE PAGES

    Walker, Donald; Breen, Amy; Druckenmiller, Lisa; ...

    2016-05-17

    The Alaska Arctic Vegetation Archive (AVA-AK, GIVD-ID: NA-US-014) is a free, publically available database archive of vegetation-plot data from the Arctic tundra region of northern Alaska. The archive currently contains 24 datasets with 3,026 non-overlapping plots. Of these, 74% have geolocation data with 25-m or better precision. Species cover data and header data are stored in a Turboveg database. A standardized Pan Arctic Species List provides a consistent nomenclature for vascular plants, bryophytes, and lichens in the archive. A web-based online Alaska Arctic Geoecological Atlas (AGA-AK) allows viewing and downloading the species data in a variety of formats, and providesmore » access to a wide variety of ancillary data. We conducted a preliminary cluster analysis of the first 16 datasets (1,613 plots) to examine how the spectrum of derived clusters is related to the suite of datasets, habitat types, and environmental gradients. Here, we present the contents of the archive, assess its strengths and weaknesses, and provide three supplementary files that include the data dictionary, a list of habitat types, an overview of the datasets, and details of the cluster analysis.« less

  12. Birth of an 'Asian cool' reference genome: AK1.

    PubMed

    Kim, Changhoon

    2016-12-01

    The human reference genome, maintained by the Genome Reference Consortium, is conceivably the most complete genome assembly ever, since its first construction. It has continually been improved by incorporating corrections made to the previous assemblies, thanks to various technological advances. Many currently-ongoing population sequencing projects have been based on this reference genome, heightening hopes of the development of useful medical applications of genomic information, thanks to the recent maturation of high-throughput sequencing technologies. However, just one reference genome does not fit all the populations across the globe, because of the large diversity in genomic structures and technical limitations inherent to short read sequencing methods. The recent success in de novo construction of the highly contiguous Asian diploid genome AK1, by combining single molecule technologies with routine sequencing data without resorting to traditional clone-by-clone sequencing and physical mapping, reveals the nature of genomic structure variation by detecting thousands of novel structural variations and by finally filling in some of the prior gaps which had persistently remained in the current human reference genome. Now it is expected that the AK1 genome, soon to be paired with more upcoming de novo assembled genomes, will provide a chance to explore what it is really like to use ancestry-specific reference genomes instead of hg19/hg38 for population genomics. This is a major step towards the furthering of genetically-based precision medicine. [BMB Reports 2016; 49(12): 653-654].

  13. Analysis of the topological properties of the proximal femur on a regional scale: evaluation of multi-detector CT-scans for the assessment of biomechanical strength using local Minkowski functionals in 3D

    NASA Astrophysics Data System (ADS)

    Boehm, H. F.; Link, T. M.; Monetti, R. A.; Kuhn, V.; Eckstein, F.; Raeth, C. W.; Reiser, M.

    2006-03-01

    In our recent studies on the analysis of bone texture in the context of Osteoporosis, we could already demonstrate the great potential of the topological evaluation of bone architecture based on the Minkowski Functionals (MF) in 2D and 3D for the prediction of the mechanical strength of cubic bone specimens depicted by high resolution MRI. Other than before, we now assess the mechanical characteristics of whole hip bone specimens imaged by multi-detector computed tomography. Due to the specific properties of the imaging modality and the bone tissue in the proximal femur, this requires to introduce a new analysis method. The internal architecture of the hip is functionally highly specialized to withstand the complex pattern of external and internal forces associated with human gait. Since the direction, connectivity and distribution of the trabeculae changes considerably within narrow spatial limits it seems most reasonable to evaluate the femoral bone structure on a local scale. The Minkowski functionals are a set of morphological descriptors for the topological characterization of binarized, multi-dimensional, convex objects with respect to shape, structure, and the connectivity of their components. The MF are usually used as global descriptors and may react very sensitively to minor structural variations which presents a major limitation in a number of applications. The objective of this work is to assess the mechanical competence of whole hip bone specimens using parameters based on the MF. We introduce an algorithm that considers the local topological aspects of the bone architecture of the proximal femur allowing to identify regions within the bone that contribute more to the overall mechanical strength than others.

  14. Photometric analysis of overcontact binaries AK Her, HI Dra, V1128 Tau, and V2612 Oph

    SciTech Connect

    Çalışkan, Ş.; Özavcı, İ.; Baştürk, Ö.; Şenavcı, H. V.; Kılıçoğlu, T.; Yılmaz, M.; Selam, S. O.; Latković, O.; Djurašević, G.; Cséki, A. E-mail: ozavci@science.ankara.edu.tr E-mail: hvsenavci@ankara.edu.tr E-mail: mesutyilmaz@ankara.edu.tr E-mail: olivia@aob.rs E-mail: attila@aob.rs

    2014-12-01

    We analyze new, high quality multicolor light curves of four overcontact binaries: AK Her, HI Dra, V1128 Tau, and V2612 Oph, and determine their orbital and physical parameters using the modeling program of G. Djurasevic and recently published results of radial velocity studies. The achieved precision in absolute masses is between 10% and 20%, and the precision in absolute radii is between 5% and 10%. All four systems are W UMa-type binaries with bright or dark spots indicative of mass and energy transfer or surface activity. We estimate the distances and the ages of the systems using the luminosities computed through our analysis, and perform an O – C study for V1128 Tau, which reveals a complex period variation that can be interpreted in terms of mass loss/exchange and either the presence of the third body, or the magnetic activity on one of the components. We conclude that further observations of these systems are needed to deepen our understanding of their nature and variability.

  15. 77 FR 49720 - Establishment of Class E Airspace; Chenega Bay, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-17

    ... airspace at Chenega Bay, AK, to accommodate aircraft using a new Area Navigation (RNAV) Global Positioning System (GPS) standard instrument approach procedures at Chenega Bay Airport. This improves the safety...

  16. 78 FR 76055 - Establishment of Class E Airspace; Donlin Creek, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ... INFORMATION: History On September 24, 2013, the FAA published in the Federal Register a notice of proposed... airspace areas extending upward from 700 feet or more above the surface of the earth. * * * * * AAL AK...

  17. 75 FR 5145 - AK Steel Corporation, Mansfield Works Division, Mansfield, OH; Notice of Affirmative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration AK Steel Corporation, Mansfield Works Division, Mansfield, OH; Notice of Affirmative Determination Regarding Application for Reconsideration By application dated...

  18. A retrospective comparison of smart prep and test bolus multi-detector CT pulmonary angiography protocols

    SciTech Connect

    Suckling, Tara; Smith, Tony; Reed, Warren

    2013-06-15

    Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 and February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.

  19. Results from ORNL characterization of ZrO2-500-AK2 - surrogate TRISO material

    SciTech Connect

    Kercher, Andrew K; Hunn, John D

    2005-06-01

    This document is a compilation of the characterization data for the TRISO-coated surrogate particles designated ZrO2-500-AK2 that was produced at Oak Ridge National Laboratory (ORNL) as part of the Advanced Gas Reactor Fuel Development and Qualification (AGR) program. The ZrO2-500-AK2 material contains nominally 500 {micro}m kernels of yttria-stabilized zirconia (YSZ) coated with all TRISO layers (buffer, inner pyrocarbon, silicon carbide, and outer pyrocarbon). The ZrO2-500-AK2 material was created for: (1) irradiation testing in the High Flux Isotope Reactor (HFIR) and (2) limited dissemination to laboratories as deemed appropriate to the AGR program. This material was created midway into a TRISO fuel development program to accommodate a sudden opportunity to perform irradiation testing on surrogate material. While the layer deposition processes were chosen based on the best technical understanding at the time, technical progress at ORNL has led to an evolution in the perceived optimal deposition conditions since the creation of ZrO2-500-AK2. Thus, ZrO2-500-AK2 contains a reasonable TRISO microstructure, but does differ significantly from currently produced TRISO surrogates and fuel at ORNL. In this document, characterization data of the ZrO2-500-AK2 surrogate includes: size, shape, coating thickness, and density.

  20. Can multidetector CT detect the site of gastrointestinal tract injury in trauma? – A retrospective study

    PubMed Central

    Panda, Ananya; Kumar, Atin; Gamanagatti, Shivanand; Das, Ranjita; Paliwal, Swati; Gupta, Amit; Kumar, Subodh

    2017-01-01

    PURPOSE We aimed to assess the performance of computed tomography (CT) in localizing site of traumatic gastrointestinal tract (GIT) injury and determine the diagnostic value of CT signs in site localization. METHODS CT scans of 97 patients with surgically proven GIT or mesenteric injuries were retrospectively reviewed by radiologists blinded to surgical findings. Diagnosis of either GIT or mesenteric injuries was made. In patients with GIT injuries, site of injury and presence of CT signs such as focal bowel wall hyperenhancement, hypoenhancement, wall discontinuity, wall thickening, extramural air, intramural air, perivisceral infiltration, and active vascular contrast leak were evaluated. RESULTS Out of 97 patients, 90 had GIT injuries (70 single site injuries and 20 multiple site injuries) and seven had isolated mesenteric injury. The overall concordance between CT and operative findings for exact site localization was 67.8% (61/90), partial concordance rate was 11.1% (10/90), and discordance rate was 21.1% (19/90). For single site localization, concordance rate was 77.1% (54/70), discordance rate was 21.4% (15/70), and partial concordance rate was 1.4% (1/70). In multiple site injury, concordance rate for all sites of injury was 35% (7/20), partial concordance rate was 45% (9/20), and discordance rate was 20% (4/20). For upper GIT injuries, wall discontinuity was the most accurate sign for localization. For small bowel injury, intramural air and hyperenhancement were the most specific signs for site localization, while for large bowel injury, wall discontinuity and hypoenhancement were the most specific signs. CONCLUSION CT performs better in diagnosing small bowel injury compared with large bowel injury. CT can well predict the presence of multiple site injury but has limited performance in exact localization of all injury sites. PMID:27924777

  1. Down-Regulation of lncRNA-AK001085 and its Influences on the Diagnosis of Ankylosing Spondylitis.

    PubMed

    Li, Xiang; Chai, Wei; Zhang, Guoqiang; Ni, Ming; Chen, Jiying; Dong, Jiyuan; Zhou, Yonggang; Hao, Libo; Bai, Yang; Wang, Yan

    2017-01-02

    BACKGROUND Long non-coding RNAs (lncRNAs) have been confirmed to play an important role in the development and progression of diseases. Ankylosing spondylitis (AS) is a chronic inflammatory systemic disease and it is hard to be found in early time. The purpose of this study was to investigate the role of lncRNA-AK001085 in the diagnosis of AS. MATERIAL AND METHODS The expression of lncRNA-AK001085 was detected by quantitative real-time polymerase chain reaction (qRT-PCR) analysis. The relationship between its expression and clinicopathologic characteristics was also analyzed. Meanwhile the correlation between lncRNA-AK001085 expression and diseases activity indexes was estimated. In addition, the value of it in the diagnosis of AS was explored through establishing receiver operating characteristic (ROC) curve. RESULTS Serum lncRNA-AK001085 expression was decreased in patients with AS compared with healthy individuals. And its expression was proved to be influenced by ever cigarette smoker, exercise level and occupational activity level. Besides, the correlation of the expression of lncRNA-AK001085 and disease activity indexes (BASDI, ASDAS, ESR, CRP) were all negative, which suggested that the lncRNA-AK001085 was significantly lower in patients with a high disease activity score. It might showed that the expression of lncRNA-AK001085 affected the activity of AS. CONCLUSIONS LncRNA-AK001085 was down-regulated in AS patients and it could be an independent diagnostic indicator.

  2. Down-Regulation of lncRNA-AK001085 and its Influences on the Diagnosis of Ankylosing Spondylitis

    PubMed Central

    Li, Xiang; Chai, Wei; Zhang, Guoqiang; Ni, Ming; Chen, Jiying; Dong, Jiyuan; Zhou, Yonggang; Hao, Libo; Bai, Yang; Wang, Yan

    2017-01-01

    Background Long non-coding RNAs (lncRNAs) have been confirmed to play an important role in the development and progression of diseases. Ankylosing spondylitis (AS) is a chronic inflammatory systemic disease and it is hard to be found in early time. The purpose of this study was to investigate the role of lncRNA-AK001085 in the diagnosis of AS. Material/Methods The expression of lncRNA-AK001085 was detected by quantitative real-time polymerase chain reaction (qRT-PCR) analysis. The relationship between its expression and clinicopathologic characteristics was also analyzed. Meanwhile the correlation between lncRNA-AK001085 expression and diseases activity indexes was estimated. In addition, the value of it in the diagnosis of AS was explored through establishing receiver operating characteristic (ROC) curve. Results Serum lncRNA-AK001085 expression was decreased in patients with AS compared with healthy individuals. And its expression was proved to be influenced by ever cigarette smoker, exercise level and occupational activity level. Besides, the correlation of the expression of lncRNA-AK001085 and disease activity indexes (BASDI, ASDAS, ESR, CRP) were all negative, which suggested that the lncRNA-AK001085 was significantly lower in patients with a high disease activity score. It might showed that the expression of lncRNA-AK001085 affected the activity of AS. Conclusions LncRNA-AK001085 was down-regulated in AS patients and it could be an independent diagnostic indicator. PMID:28042142

  3. 75 FR 12976 - Amendment of Restricted Area R-2204 High and R-2204 Low; Oliktok Point, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... TRANSPORTATION Federal Aviation Administration 14 CFR Part 73 RIN 2120-AA66 Amendment of Restricted Area R-2204 High and R-2204 Low; Oliktok Point, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action amends R-2204 High and R-2204 Low at Oliktok Point, AK, by...

  4. Complete Genome Sequence of Pontibacter akesuensis Strain AKS 1T, Which Exhibits Robust Nutrient Metabolism in Harsh Environments

    PubMed Central

    Wang, Yang; He, Kaiyong; Jiang, Yongzhong; Shen, Jiate

    2016-01-01

    Pontibacter akesuensis strain AKS 1T was found in Akesu, Xinjiang Province, China, and exhibits the extraordinary ability to metabolize various substrates and is resistant to solar radiation. To gain insight into the bacterial genetic determinants for this adaptability, we report the complete genome sequence of strain AKS 1T. PMID:27795233

  5. Pulmonary capillary hemangiomatosis: a focus on the EIF2AK4 mutation in onset and pathogenesis

    PubMed Central

    Ma, Lijiang; Bao, Ruijun

    2015-01-01

    Pulmonary capillary hemangiomatosis (PCH) is a pulmonary vascular disease that mainly affects small capillaries in the lung, and is often misdiagnosed as pulmonary arterial hypertension or pulmonary veno-occlusive disease due to similarities in their clinical presentations, prognosis, and management. In patients who are symptomatic, there is a high mortality rate with median survival of 3 years after diagnosis. Both idiopathic and familial PCH cases are being reported, indicating there is genetic component in disease etiology. Mutations in the eukaryotic translation initiation factor 2α kinase 4 (EIF2AK4) gene were identified in familial and idiopathic PCH cases, suggesting EIF2AK4 is a genetic risk factor for PCH. EIF2AK4 mutations were identified in 100% (6/6) of autosomal recessively inherited familial PCH and 20% (2/10) of sporadic PCH cases. EIF2AK4 is a member of serine/threonine kinases. It downregulates protein synthesis in response to a variety of cellular stress such as hypoxia, viral infection, and amino acid deprivation. Bone morphogenetic protein receptor 2 (BMPR2) is a major genetic risk factor in pulmonary arterial hypertension and EIF2AK4 potentially connects with BMPR2 to cause PCH. L-Arginine is substrate of nitric oxide synthase, and L-arginine is depleted during the production of nitric oxide, which may activate EIF2AK4 to inhibit protein synthesis and negatively regulate vasculogenesis. Mammalian target of rapamycin and EIF2α kinase are two major pathways for translational regulation. Mutant EIF2AK4 could promote proliferation of small pulmonary arteries by crosstalk with mammalian targets of the rapamycin signaling pathway. EIF2AK4 may regulate angiogenesis by modulating the immune system in PCH pathogenesis. The mechanisms of abnormal capillary angiogenesis are suggested to be similar to that of tumor vascularization. Specific therapies were developed according to pathogenesis and are proved to be effective in reported cases. Targeting the

  6. M. tuberculosis ferritin (Rv3841): Potential involvement in Amikacin (AK) & Kanamycin (KM) resistance.

    PubMed

    Sharma, Divakar; Lata, Manju; Faheem, Mohammad; Khan, Asad Ullah; Joshi, Beenu; Venkatesan, Krishnamurthy; Shukla, Sangeeta; Bisht, Deepa

    2016-09-16

    Tuberculosis is an infectious disease, caused by one of the most successful human pathogen, Mycobacterium tuberculosis. Aminoglycosides, Amikacin (AK) & Kanamycin (KM) are commonly used to treat drug resistant tuberculosis. They target the protein synthesis machinery by interacting with several steps of translation. Several explanations have been proposed to explain the mechanism of aminoglycoside resistance but still our information is inadequate. Iron storing/interacting proteins were found to be overexpressed in aminoglycosides resistant isolates. Iron assimilation and utilization in M. tuberculosis plays a crucial role in growth, virulence and latency. To establish the relationship of ferritin with AK & KM resistance ferritin (Rv3841/bfrB) was cloned, expressed and antimicrobial drug susceptibility testing (DST) was carried out. Rv3841/bfrB gene was cloned and expressed in E. coli BL21 using pQE2 expression vector. Etest results for DST against AK & KM showed that the minimum inhibitory concentration (MIC) of ferritin recombinant cells was changed. Recombinants showed two fold changes in MIC with AK and three fold with KM E-strips. Overexpression of ferritin reflect the MIC shift which might be playing a critical role in the survival of mycobacteria by inhibiting/modulating the effects of AK & KM. String analysis also suggests that ferritin interacted with few proteins which are directly and indirectly involved in M. tuberculosis growth, Iron assimilation, virulence, resistance, stresses and latency.

  7. Computed tomography evaluation for transcatheter aortic valve implantation (TAVI): imaging of the aortic root and iliac arteries.

    PubMed

    Schoenhagen, Paul; Kapadia, Samir R; Halliburton, Sandra S; Svensson, Lars G; Tuzcu, E Murat

    2011-01-01

    For patients with severe aortic stenosis, open-heart surgical valve replacement remains the current clinical standard with documented, excellent long-term outcome. Over the past few years, transcatheter aortic valve implantation (TAVI) has developed into a treatment alternative for high-risk patients with severe aortic stenosis. Because transcatheter valvular procedures are characterized by lack of exposure of the operative field, image guidance is critical. This Pictorial Essay describes the role of 3-dimensional imaging with multidetector row computed tomography for detailed reconstructions of the aortic valve, aortic root, and iliac arteries in the context of TAVI.

  8. Comparative Raman spectroscopic study of phase stability and anharmonic effects in AZr2(PO4)3 (A=K, Rb and Cs).

    PubMed

    Kamali, K; Ravindran, T R; Ravi, C

    2016-02-15

    AZr2(PO4)3 (A=Na, K, Rb, Cs) are a set of framework structured compounds that exhibit tunable ultralow thermal expansion over the wide temperature range of 293-1273K. We report a systematic Raman spectroscopic investigation on AZr2(PO4)3 (A=K, Rb and Cs) compounds as a function of temperature in the range 80-860K and pressures of up to 32GPa. To get insight into the thermal expansion property, phonon anharmonicity has been investigated by studying the temperature and pressure dependence of Raman peak shifts and line widths and computed bulk modulus. We have compared the phase transition and amorphization pressures of the various members of AZr2(PO4)3 to account for the stability of the ambient rhombohedral phase. We find that unlike most of the anomalous thermal expansion materials, in AZr2(PO4)3 (A=K, Rb and Cs), the phonons that are anharmonic with temperature do not necessarily exhibit anharmonicity with pressure.

  9. The role of mobile computed tomography in mass fatality incidents.

    PubMed

    Rutty, Guy N; Robinson, Claire E; BouHaidar, Ralph; Jeffery, Amanda J; Morgan, Bruno

    2007-11-01

    Mobile multi-detector computed tomography (MDCT) scanners are potentially available to temporary mortuaries and can be operational within 20 min of arrival. We describe, to our knowledge, the first use of mobile MDCT for a mass fatality incident. A mobile MDCT scanner attended the disaster mortuary after a five vehicle road traffic incident. Five out of six bodies were successfully imaged by MDCT in c. 15 min per body. Subsequent full radiological analysis took c. 1 h per case. The results were compared to the autopsy examinations. We discuss the advantages and disadvantages of imaging with mobile MDCT in relation to mass fatality work, illustrating the body pathway process, and its role in the identification of the pathology, personal effects, and health and safety hazards. We propose that the adoption of a single modality of mobile MDCT could replace the current use of multiple radiological sources within a mass fatality mortuary.

  10. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Gu, J.; Bednarz, B.; Caracappa, P. F.; Xu, X. G.

    2009-05-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  11. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations.

    PubMed

    Gu, J; Bednarz, B; Caracappa, P F; Xu, X G

    2009-05-07

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  12. A Novel Alpha Kinase EhAK1 Phosphorylates Actin and Regulates Phagocytosis in Entamoeba histolytica

    PubMed Central

    Mansuri, M. Shahid; Bhattacharya, Sudha; Bhattacharya, Alok

    2014-01-01

    Phagocytosis plays a key role in nutrient uptake and virulence of the protist parasite Entamoeba histolytica. Phagosomes have been characterized by proteomics, and their maturation in the cells has been studied. However, there is so far not much understanding about initiation of phagocytosis and formation of phagosomes at the molecular level. Our group has been studying initiation of phagocytosis and formation of phagosomes in E. histolytica, and have described some of the molecules that play key roles in the process. Here we show the involvement of EhAK1, an alpha kinase and a SH3 domain containing protein in the pathway that leads to formation of phagosomes using red blood cell as ligand particle. A number of approaches, such as proteomics, biochemical, confocal imaging using specific antibodies or GFP tagged molecules, expression down regulation by antisense RNA, over expression of wild type and mutant proteins, were used to understand the role of EhAK1 in phagocytosis. EhAK1 was found in the phagocytic cups during the progression of cups, until closure of phagosomes, but not in the phagosomes themselves. It is recruited to the phagosomes through interaction with the calcium binding protein EhCaBP1. A reduction in phagocytosis was observed when EhAK1 was down regulated by antisense RNA, or by over expression of the kinase dead mutant. G-actin was identified as one of the major substrates of EhAK1. Phosphorylated actin preferentially accumulated at the phagocytic cups and over expression of a phosphorylation defective actin led to defects in phagocytosis. In conclusion, we describe an important component of the pathway that is initiated on attachment of red blood cells to E. histolytica cells. The main function of EhAK1 is to couple signalling events initiated after accumulation of EhC2PK to actin dynamics. PMID:25299184

  13. A novel alpha kinase EhAK1 phosphorylates actin and regulates phagocytosis in Entamoeba histolytica.

    PubMed

    Mansuri, M Shahid; Bhattacharya, Sudha; Bhattacharya, Alok

    2014-10-01

    Phagocytosis plays a key role in nutrient uptake and virulence of the protist parasite Entamoeba histolytica. Phagosomes have been characterized by proteomics, and their maturation in the cells has been studied. However, there is so far not much understanding about initiation of phagocytosis and formation of phagosomes at the molecular level. Our group has been studying initiation of phagocytosis and formation of phagosomes in E. histolytica, and have described some of the molecules that play key roles in the process. Here we show the involvement of EhAK1, an alpha kinase and a SH3 domain containing protein in the pathway that leads to formation of phagosomes using red blood cell as ligand particle. A number of approaches, such as proteomics, biochemical, confocal imaging using specific antibodies or GFP tagged molecules, expression down regulation by antisense RNA, over expression of wild type and mutant proteins, were used to understand the role of EhAK1 in phagocytosis. EhAK1 was found in the phagocytic cups during the progression of cups, until closure of phagosomes, but not in the phagosomes themselves. It is recruited to the phagosomes through interaction with the calcium binding protein EhCaBP1. A reduction in phagocytosis was observed when EhAK1 was down regulated by antisense RNA, or by over expression of the kinase dead mutant. G-actin was identified as one of the major substrates of EhAK1. Phosphorylated actin preferentially accumulated at the phagocytic cups and over expression of a phosphorylation defective actin led to defects in phagocytosis. In conclusion, we describe an important component of the pathway that is initiated on attachment of red blood cells to E. histolytica cells. The main function of EhAK1 is to couple signalling events initiated after accumulation of EhC2PK to actin dynamics.

  14. Differentiation of Malignant and Benign Incidental Breast Lesions Detected by Chest Multidetector-Row Computed Tomography: Added Value of Quantitative Enhancement Analysis

    PubMed Central

    Lin, Yu-Pang; Hsu, Hsian-He; Ko, Kai-Hsiung; Chu, Chi-Ming; Chou, Yu-Ching; Chang, Wei-Chou; Chang, Tsun-Hou

    2016-01-01

    To retrospectively determine the association between breast lesion morphology and malignancy and to determine the optimal value of lesion enhancement (HU, Hounsfield units) to improve the diagnostic accuracy of breast cancer in patients with incidental breast lesions (IBLs). A total of 97 patients with 102 IBLs detected from July 2009 to December 2012 were enrolled in this study. Two radiologists analyzed CT images for the presence of malignancy based on the morphology of the lesions alone and in combination with an enhancement value (HU) analysis. There were 36 malignant and 66 benign IBLs. When the morphology and enhancement values were combined, the sensitivity, specificity, and accuracy were 92%, 97%, and 95%, respectively, for reader 1 and 89%, 94%, and 92%, respectively, for reader 2. The addition of HU values led to correct changes in the diagnosis; specifically, the accuracy of the diagnosis of reader 1 and reader 2 improved by 6.9% and 11.8%, respectively. The addition of the enhancement value (HU) to the CT morphology improved the diagnostic accuracy in the differentiation of malignant from benign IBLs by using the region of interest (ROI) to measure the HU within the most suspicious part of the lesion. PMID:27128524

  15. Non-invasive Detection of Aortic and Coronary Atherosclerosis in Homozygous Familial Hypercholesterolemia by 64 Slice Multi-detector Row Computed Tomography Angiography

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector-row ...

  16. Non-invasive detection of aortic and coronary atherosclerosis in homozygous familial hypercholesterolemia by 64 slice multi-detector row computed tomography angiography

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...

  17. 78 FR 48299 - Establishment of Class D Airspace; Bryant AAF, Anchorage, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-08

    ... Federal Aviation Administration 14 CFR Part 71 Establishment of Class D Airspace; Bryant AAF, Anchorage... establishes Class D airspace at Bryant Army Airfield (AAF), Anchorage AK. This action provides controlled... Federal Register a notice of proposed rulemaking (NPRM) to establish Class D airspace at Bryant...

  18. Episodic Upwelling of Zooplankton Within a Bowhead Whale Feeding Area near Barrow, AK

    DTIC Science & Technology

    2009-09-30

    bowhead whale on the shelf near Barrow. This will permit educated decisions regarding development of industry, tourism , and commerce in this region by...DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Episodic Upwelling of Zooplankton within a Bowhead Whale ...oceanographic characteristics and mechanisms on the shelf near Barrow, AK that together produce a favorable feeding environment for the bowhead whale

  19. 77 FR 75598 - Proposed Establishment of Class E Airspace; White Mountain, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-21

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Establishment of Class E Airspace; White Mountain...). SUMMARY: This action proposes to establish Class E airspace at White Mountain Airport, White Mountain, AK... management of Instrument Flight Rules (IFR) operations at White Mountain Airport. DATES: Comments must...

  20. 77 FR 23269 - Determination That FUNDUSCEIN-25 (fluorescein sodium injection), 25%, and AK-FLUOR (fluorescein...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    ... HUMAN SERVICES Food and Drug Administration Determination That FUNDUSCEIN-25 (fluorescein sodium injection), 25%, and AK-FLUOR (fluorescein sodium injection), 25%, Were Not Withdrawn From Sale for Reasons... Food and Drug Administration (FDA) has determined that FUNDUSCEIN-25 (fluorescein sodium injection),...

  1. The Library Haines Built: Best Small Library in America 2005--Haines Borough Public Library, Haines, AK

    ERIC Educational Resources Information Center

    Berry, John N., III

    2005-01-01

    "Community involvement," the standard cliche, does not come close to capturing the spirit and action that have structured the building, programs, collections, and services of the Haines Borough Public Library (HBPL), AK. Those achievements make HBPL the winner of the first annual award for the Best Small Library in America, cosponsored…

  2. 78 FR 65239 - Proposed Establishment of Class E Airspace; Brevig Mission, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Establishment of Class E Airspace; Brevig Mission...). SUMMARY: This action proposes to establish Class E airspace at Brevig Mission Airport, Brevig Mission, AK... enhance the safety and management of aircraft operations at the airport. DATES: Comments must be...

  3. 77 FR 31353 - An Assessment of Potential Mining Impacts on Salmon Ecosystems of Bristol Bay, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-25

    ... AGENCY An Assessment of Potential Mining Impacts on Salmon Ecosystems of Bristol Bay, AK AGENCY... of Potential Mining Impacts on Salmon Ecosystems of Bristol Bay, Alaska'' (EPA-910-R-12-004a-d). The... significance of Bristol Bay's ecological resources and evaluate the potential impacts of large-scale mining...

  4. 75 FR 30746 - Proposed Revocation and Establishment of Class E Airspace; Northeast, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-02

    .... The recent removal of a Colored Federal Airway near Kaktovik, AK, duplication of controlled airspace.... The Docket Office (telephone 1-800-647-5527) is on the plaza level of the Department of Transportation... allow commercial air operations through what is now uncontrolled airspace above 1,200 feet. Air...

  5. 77 FR 29358 - Kenai National Wildlife Refuge, Soldotna, AK; Environmental Impact Statement for the Shadura...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-17

    ... Fish and Wildlife Service Kenai National Wildlife Refuge, Soldotna, AK; Environmental Impact Statement... estate within the Refuge. We intend to gather information necessary to prepare an environmental impact... an application for, and intend to prepare an environmental impact statement (EIS) for, a...

  6. 75 FR 71046 - Proposed Revision of Class E Airspace; Barrow, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-22

    ... rulemaking (NPRM). SUMMARY: This action proposes to revise Class E airspace at Wiley Post/ Will Rogers...) part 71 by revising Class E airspace at Wiley Post/Will Rogers memorial Airport at Barrow, AK, to... operations at Wiley Post/Will Rogers Memorial Airport by ensuring that the Class E airspace is sufficient...

  7. 75 FR 32317 - Proposed Revocation of Colored Federal Airway G-4; AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Revocation of Colored Federal Airway G-4; AK...: This action proposes to remove Colored Federal Airway Green 4 (G-4) from the National Airspace System...) part 71 by removing Colored Federal airway G-4 associated with the planned BTS NDB decommissioning...

  8. 75 FR 47737 - Proposed Revocation of Colored Federal Airway G-4; AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-09

    ... G-4; AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed rulemaking... Airway Green (G-4) in Alaska. The FAA has determined that the withdrawal is warranted since the proposed... NPRM proposing to remove Federal Airway G-4 (75 FR 32317), Docket No. FAA- 2010-0453. A review...

  9. 78 FR 12084 - Public Land Order No. 7808; Extension of Public Land Order No. 6965; AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-21

    ... Bureau of Land Management Public Land Order No. 7808; Extension of Public Land Order No. 6965; AK AGENCY: Bureau of Land Management, Interior. ACTION: Public Land Order. SUMMARY: This order extends the withdrawal created by Public Land Order (PLO) No. 6965 for an additional 20-year period. This extension...

  10. 77 FR 65253 - Amendment of Area Navigation Route T-240; AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-26

    ... Administration 14 CFR Part 71 RIN 2120-AA66 Amendment of Area Navigation Route T-240; AK AGENCY: Federal Aviation... description of area navigation (RNAV) route T-240 in Alaska by removing one waypoint that is no longer... route description is amended to include the names of the navigation aids that comprise the route....

  11. 78 FR 285 - Supplemental Final Environmental Impact Statement for Healy Power Generation Unit #2, Healy, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-03

    ... prepare a supplemental final environmental impact statement (SFEIS) to update information in the... Impact Statement for Healy Power Generation Unit 2, Healy, AK AGENCY: Rural Utilities Service, USDA. ACTION: Notice of Intent to Prepare a Supplemental Final Environmental Impact Statement. SUMMARY:...

  12. 78 FR 22190 - Modification of Area Navigation (RNAV) Route T-266; AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-15

    ... T-266; AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action modifies low-altitude RNAV route T-266 in the state of Alaska by removing two non-directional... the Federal Register a notice of proposed rulemaking (NPRM) to modify T-266 in the state of Alaska...

  13. 75 FR 34393 - Proposed Establishment of Class E Airspace; Port Clarence, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-17

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Establishment of Class E Airspace; Port Clarence...). SUMMARY: This action proposes to establish Class E airspace at Port Clarence Coast Guard Station (CGS), AK... approach procedure. This instrument approach development at the Port Clarence CGS Airport has made...

  14. Computers and Computer Resources.

    ERIC Educational Resources Information Center

    Bitter, Gary

    1980-01-01

    This resource directory provides brief evaluative descriptions of six popular home computers and lists selected sources of educational software, computer books, and magazines. For a related article on microcomputers in the schools, see p53-58 of this journal issue. (SJL)

  15. Application of an asymmetric flow field flow fractionation multi-detector approach for metallic engineered nanoparticle characterization--prospects and limitations demonstrated on Au nanoparticles.

    PubMed

    Hagendorfer, Harald; Kaegi, Ralf; Traber, Jacqueline; Mertens, Stijn F L; Scherrers, Roger; Ludwig, Christian; Ulrich, Andrea

    2011-11-14

    In this work we discuss about the method development, applicability and limitations of an asymmetric flow field flow fractionation (A4F) system in combination with a multi-detector setup consisting of UV/vis, light scattering, and inductively coupled plasma mass spectrometry (ICPMS). The overall aim was to obtain a size dependent-, element specific-, and quantitative method appropriate for the characterization of metallic engineered nanoparticle (ENP) dispersions. Thus, systematic investigations of crucial method parameters were performed by employing well characterized Au nanoparticles (Au-NPs) as a defined model system. For good separation performance, the A4F flow-, membrane-, and carrier conditions were optimized. To obtain reliable size information, the use of laser light scattering based detectors was evaluated, where an online dynamic light scattering (DLS) detector showed good results for the investigated Au-NP up to a size of 80 nm in hydrodynamic diameter. To adapt large sensitivity differences of the various detectors, as well as to guarantee long term stability and minimum contamination of the mass spectrometer a split-flow concept for coupling ICPMS was evaluated. To test for reliable quantification, the ICPMS signal response of ionic Au standards was compared to that of Au-NP. Using proper stabilization with surfactants, no difference for concentrations of 1-50 μg Au L(-1) in the size range from 5 to 80 nm for citrate stabilized dispersions was observed. However, studies using different A4F channel membranes showed unspecific particle-membrane interaction resulting in retention time shifts and unspecific loss of nanoparticles, depending on the Au-NP system as well as membrane batch and type. Thus, reliable quantification and discrimination of ionic and particular species was performed using ICPMS in combination with ultracentrifugation instead of direct quantification with the A4F multi-detector setup. Figures of merit were obtained, by comparing the

  16. EIF2AK4 mutation in pulmonary veno-occlusive disease

    PubMed Central

    Liang, Li; Ma, Guofeng; Chen, Kai; Liu, Yangxiang; Wu, Xiaohong; Ying, Kejing; Zhang, Ruifeng

    2016-01-01

    Abstract Background: Pulmonary veno-occlusive disease (PVOD) is a rare and devastating cause of pulmonary arterial hypertension with a non-specific clinical presentation and a relatively specific presentation in high-resolution thoracic CT scan images. Definitive diagnosis is made by histological examination in previous. According to the 2015 ESC/ERS Guidelines, detection of a mutation in the eukaryotic translation initiation factor 2 alpha kinase 4 (EIF2AK4) without histological confirmation is recommended to validate the diagnosis of PVOD. Methods: We report the case of a 27-year-old man who was admitted for persistent cough and dyspnea that had lasted for 5 months and had developed and experienced progressive dyspnea for the last 2 months. The echocardiogram and right heart catheterization without vasodilator challenge confirmed the diagnosis of pulmonary arterial hypertension. Other tests, such as high-resolution thoracic CT scan, V/Q scan, pulmonary function test with diffusion capacity, and blood tests, excluded other associated diseases which could have caused pulmonary hypertension. Results: The initial diagnosis at admission was idiopathic pulmonary arterial hypertension and an oral vasodilator (sildenafil) was given. However, the dyspnea subsequently worsened, and the patient was transferred to a regional lung transplant center, where he died of heart failure 1 week later. Using exome sequencing, we found an EIF2AK4 mutation, which was sufficient to confirm the diagnosis of PVOD. Conclusion: This is the first reported case of EIF2AK4 mutation in PVOD in a Chinese patient population. We found the frameshift EIF2AK4 mutation c.1392delT (p.Arg465fs) in this case. Up to now, there has been a paucity of data on this rare disease, and the exact role of EIF2AK4 loss-of-function mutations in the pathogenesis of PVOD is still unknown. More investigations should be conducted in the future. PMID:27684876

  17. Genomic characterization of Sinorhizobium meliloti AK21, a wild isolate from the Aral Sea Region.

    PubMed

    Molina-Sánchez, María Dolores; López-Contreras, José Antonio; Toro, Nicolás; Fernández-López, Manuel

    2015-01-01

    The symbiotic, nitrogen-fixing bacterium Sinorhizobium meliloti has been widely studied due to its ability to improve crop yields through direct interactions with leguminous plants. S. meliloti AK21 is a wild type strain that forms nodules on Medicago plants in saline and drought conditions in the Aral Sea Region. The aim of this work was to establish the genetic similarities and differences between S. meliloti AK21 and the reference strain S. meliloti 1021. Comparative genome hybridization with the model reference strain S. meliloti 1021 yielded 365 variable genes, grouped into 11 regions in the three main replicons in S. meliloti AK21. The most extensive regions of variability were found in the symbiotic plasmid pSymA, which also contained the largest number of orthologous and polymorphic sequences identified by suppression subtractive hybridization. This procedure identified a large number of divergent sequences and others without homology in the databases, the further investigation of which could provide new insight into the alternative metabolic pathways present in S. meliloti AK21. We identified a plasmid replication module from the repABC replicon family, together with plasmid mobilization-related genes (traG and a VirB9-like protein), which suggest that this indigenous isolate harbors an accessory plasmid. Furthermore, the transcriptomic profiles reflected differences in gene content and regulation between S. meliloti AK21 and S. meliloti 1021 (ExpR and PhoB regulons), but provided evidence for an as yet unknown, alternative mechanism involving activation of the cbb3 terminal oxidase. Finally, phenotypic microarrays characterization revealed a greater versatility of substrate use and chemical degradation than for S. meliloti 1021.

  18. Kinetics of nutrient enhanced crude oil degradation by Pseudomonas aeruginosa AKS1 and Bacillus sp. AKS2 isolated from Guwahati refinery, India.

    PubMed

    Chettri, Bobby; Mukherjee, Arghya; Langpoklakpam, James S; Chattopadhyay, Dhrubajyoti; Singh, Arvind K

    2016-09-01

    Bacterial degradation of crude oil in response to nutrient treatments has been vastly studied. But there is a paucity of information on kinetic parameters of crude oil degradation. Here we report the nutrient stimulated kinetic parameters of crude oil degradation assessed in terms of CO2 production and oil removal by Pseudomonas aeruginosa AKS1 and Bacillus sp. AKS2. The hydrocarbon degradation rate of P. aeruginosa AKS1 in oil only amended sediment was 10.75 ± 0.65 μg CO2-C g(-1) sediment day(-1) which was similar to degradation rate in sediments with no oil. In presence of both inorganic N & P, the degradation rate increased to 47.22 ± 1.32 μg CO2-C g(-1) sediment day(-1). The half-saturation constant (Ks) and maximum degradation rate (Vmax) for P. aeruginosa AKS1 under increasing N and saturating P concentration were 13.57 ± 0.53 μg N g(-1) sediment and 39.36 ± 1.42 μg CO2-C g(-1) sediment day(-1) respectively. The corresponding values at increasing P and a constant N concentration were 1.60 ± 0.13 μg P g(-1) sediment and 43.90 ± 1.03 μg CO2-C g(-1) sediment day(-1) respectively. Similarly the degradation rate of Bacillus sp. AKS2 in sediments amended with both inorganic nutrients N & P was seven fold higher than the rates in oil only or nutrient only treated sediments. The Ks and Vmax estimates of Bacillus sp. AKS2 under increasing N and saturating P concentration were 9.96 ± 1.25 μg N g(-1) sediment and 59.96 ± 7.56 μg CO2-C g(-1) sediment day(-1) respectively. The corresponding values for P at saturating N concentration were 0.46 ± 0.24 μg P g(-1) sediment and 63.63 ± 3.54 μg CO2-C g(-1) sediment day(-1) respectively. The rates of CO2 production by both isolates were further stimulated when oil concentration was increased above 12.5 mg g(-1) sediment. However, oil degradation activity declined at oil concentration above 40 mg g(-1) sediment when treated with constant nutrient: oil ratio

  19. The role of computed tomography in terminal ballistic analysis.

    PubMed

    Rutty, G N; Boyce, P; Robinson, C E; Jeffery, A J; Morgan, B

    2008-01-01

    Terminal ballistics concerns the science of projectile behaviour within a target and includes wound ballistics that considers what happens when a projectile strikes a living being. A number of soft tissue ballistic simulants have been used to assess the damage to tissue caused by projectiles. Standard assessment of these materials, such as ballistic soap or ordnance gelatine, requires the block to be opened or that a mould to be made to visualize the wound track. This is time consuming and may affect the accuracy of the findings especially if the block dries and alters shape during the process. Therefore, accurate numerical analysis of the permanent or temporary cavity is limited. Computed tomography (CT) potentially offers a quicker non-invasive analysis tool for this task. Four commercially purchased ballistic glycerine soap blocks were used. Each had a single firearm discharged into it from a distance of approximately 15 cm using both gunshot and shotgun projectiles. After discharge, each block was imaged by a modern 16 slice multi-detector CT scanner and analysed using 3-D reconstruction software. Using the anterior-posterior and lateral scout views and the multi-plane reconstructed images, it was possible to visualize the temporary cavity, as well as the fragmentation and dispersal pattern of the projectiles, the distance travelled and angle of dispersal within the block of each projectile or fragment. A virtual cast of the temporary cavity can be also be made. Multi-detector CT with 3-D analysis software is shown to create a reliable permanent record of the projectile path allowing rapid analysis of different firearms and projectiles.

  20. Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.; Mitchell, Mark A.

    2016-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance chlorofluorocarbon-113 was banned, NASA's propulsion test facilities at Marshall Space Flight Center and Stennis Space Center have relied upon the solvent Asahiklin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

  1. Multidetector thermal field-flow fractionation as a unique tool for the tacticity-based separation of poly(methyl methacrylate)-polystyrene block copolymer micelles.

    PubMed

    Greyling, Guilaume; Pasch, Harald

    2015-10-02

    Poly(methyl methacrylate)-polystyrene (PMMA-PS) micelles with isotactic and syndiotactic coronas are prepared in acetonitrile and subjected to thermal field-flow fractionation (ThFFF) analysis at various conditions of increasing temperature gradients. It is shown for the first time that multidetector ThFFF provides comprehensive information on important micelle characteristics such as size (Dh), shape (Rg/Rh), aggregation number (Z), thermal diffusion (DT) and Soret coefficients (ST) as a function of temperature from a single injection. Moreover, it is found that micelles exhibit a unique decreasing trend in DT as a function of temperature which is independent of the tacticity of the corona and the micelle preparation method used. It is also demonstrated that ThFFF can monitor micelle to vesicle transitions as a function of temperature. In addition to ThFFF, it is found from DLS analysis that the tacticity of the corona influences the critical micelle concentration and the magnitude to which micelles expand/contract with temperature. The tacticity does not, however, influence the critical micelle temperature. Furthermore, the separation of micelles based on the tacticity of the corona highlight the unique capabilities of ThFFF.

  2. Comparison between blinded and partially blinded detection of gastric cancer with multidetector CT using surgery and endoscopic submucosal dissection as reference standards.

    PubMed

    Kim, H J; Lee, D H; Ko, Y T

    2010-08-01

    The aim of this study is to compare blinded with partially blinded detection of gastric cancer with multidetector (MD) CT by using surgery and endoscopic submucosal dissection (ESD) as reference standards. 44 patients with gastric cancer underwent MDCT with air as an oral contrast agent. Surgery was performed on 37 patients, ESD on six and surgery after ESD on one. To provide comparison cases of blinded evaluation, 38 MDCT examinations were added for cases where no focal gastric lesion was seen on endoscopy. Two radiologists, blinded to the presence, number and location of the tumours, evaluated axial and axial plus multiplanar reformation (MPR) images of 82 MDCT examinations with or without gastric cancer. For partially blinded evaluation, the same radiologists, blinded to the location and number of tumours, evaluated axial and axial plus MPR images of 44 MDCT examinations of gastric cancer. Differences in assessment were resolved by consensus. 45 gastric cancers were found in surgical and ESD specimens. Detection rates of gastric cancer from axial and axial plus MPR images during blinded evaluation and from axial and axial plus MPR images during partially blinded evaluation were 62% (28/45), 64% (29/45), 64% (29/45) and 71% (32/45), respectively. There was no statistical significance for the comparison between blinded and partially blinded detection rates of gastric cancer. The detection rate of gastric cancer with MDCT during blinded evaluation showed no specific difference compared with the detection rate of gastric cancer with MDCT during partially blinded evaluation.

  3. The Role of Three-Dimensional Multidetector CT Gastrography in the Preoperative Imaging of Stomach Cancer: Emphasis on Detection and Localization of the Tumor

    PubMed Central

    Kim, Jin Woong; Heo, Suk Hee; Lim, Hyo Soon; Lim, Nam Yeol; Park, Young Kyu; Jeong, Yong Yeon; Kang, Heoung Keun

    2015-01-01

    Multidetector CT (MDCT) gastrography has been regarded as a promising technique for the preoperative imaging of gastric cancer. It has the ability to produce various three-dimensional (3D) images. Because 3D reconstruction images are more effective and intuitive for recognizing abnormal changes in the gastric folds and subtle mucosal nodularity than two-dimensional images, 3D MDCT gastrography can enhance the detection rate of early gastric cancer, which, in turn, contributes to the improvement of the accuracy of preoperative tumor (T) staging. In addition, shaded surface display and tissue transition projection images provide a global view of the stomach, with the exact location of gastric cancer, which may replace the need for barium studies. In this article, we discuss technical factors in producing high-quality MDCT gastrographic images and present cases demonstrating the usefulness of MDCT gastrography for the detection and T staging of gastric cancer while emphasizing the significance of preoperative localization of gastric cancer in terms of surgical margin. PMID:25598676

  4. An automated system for lung nodule detection in low-dose computed tomography

    NASA Astrophysics Data System (ADS)

    Gori, I.; Fantacci, M. E.; Preite Martinez, A.; Retico, A.

    2007-03-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The results obtained on the collected database of low-dose thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  5. The U.S. M-16 rifle versus the Russian AK-47 rifle. A comparison of terminal ballistics.

    PubMed

    Swan, K G; Swan, R C; Levine, M G; Rocko, J M

    1983-09-01

    The standard U.S. military rifle (M-16) is substantially more destructive than its Russian counterpart (AK-47) when fired at short range into clay blocks, despite the fact that the AK-47 is of larger caliber and fires a much heavier bullet with a kinetic energy (muzzle) 25% greater when compared to the M-16. The decisive factor is the 40% greater muzzle velocity of the M-16.

  6. Permanent draft genome sequences of the symbiotic nitrogen fixing Ensifer meliloti strains BO21CC and AK58

    PubMed Central

    Galardini, Marco; Bazzicalupo, Marco; Biondi, Emanuele; Brambilla, Eveline; Brilli, Matteo; Bruce, David; Chain, Patrick; Chen, Amy; Daligault, Hajnalka; Davenport, Karen Walston; Deshpande, Shweta; Detter, John C.; Goodwin, Lynne A.; Han, Cliff; Han, James; Huntemann, Marcel; Ivanova, Natalia; Klenk, Hans-Peter; Kyrpides, Nikos C.; Markowitz, Victor; Mavrommatis, Kostas; Mocali, Stefano; Nolan, Matt; Pagani, Ioanna; Pati, Amrita; Pini, Francesco; Pitluck, Sam; Spini, Giulia; Szeto, Ernest; Teshima, Hazuki; Woyke, Tanja; Mengoni, Alessio

    2013-01-01

    Ensifer (syn. Sinorhizobium) meliloti is an important symbiotic bacterial species that fixes nitrogen. Strains BO21CC and AK58 were previously investigated for their substrate utilization and their plant-growth promoting abilities showing interesting features. Here, we describe the complete genome sequence and annotation of these strains. BO21CC and AK58 genomes are 6,985,065 and 6,974,333 bp long with 6,746 and 6,992 genes predicted, respectively. PMID:24976889

  7. Permanent draft genome sequences of the symbiotic nitrogen fixing Ensifer meliloti strains BO21CC and AK58.

    PubMed

    Galardini, Marco; Bazzicalupo, Marco; Biondi, Emanuele; Brambilla, Eveline; Brilli, Matteo; Bruce, David; Chain, Patrick; Chen, Amy; Daligault, Hajnalka; Davenport, Karen Walston; Deshpande, Shweta; Detter, John C; Goodwin, Lynne A; Han, Cliff; Han, James; Huntemann, Marcel; Ivanova, Natalia; Klenk, Hans-Peter; Kyrpides, Nikos C; Markowitz, Victor; Mavrommatis, Kostas; Mocali, Stefano; Nolan, Matt; Pagani, Ioanna; Pati, Amrita; Pini, Francesco; Pitluck, Sam; Spini, Giulia; Szeto, Ernest; Teshima, Hazuki; Woyke, Tanja; Mengoni, Alessio

    2013-12-20

    Ensifer (syn. Sinorhizobium) meliloti is an important symbiotic bacterial species that fixes nitrogen. Strains BO21CC and AK58 were previously investigated for their substrate utilization and their plant-growth promoting abilities showing interesting features. Here, we describe the complete genome sequence and annotation of these strains. BO21CC and AK58 genomes are 6,985,065 and 6,974,333 bp long with 6,746 and 6,992 genes predicted, respectively.

  8. Crystal structure of Clostridium acetobutylicum Aspartate kinase (CaAK): An important allosteric enzyme for amino acids production.

    PubMed

    Manjasetty, Babu A; Chance, Mark R; Burley, Stephen K; Panjikar, Santosh; Almo, Steven C

    2014-09-01

    Aspartate kinase (AK) is an enzyme which is tightly regulated through feedback control and responsible for the synthesis of 4-phospho-L-aspartate from L-aspartate. This intermediate step is at an important branch point where one path leads to the synthesis of lysine and the other to threonine, methionine and isoleucine. Concerted feedback inhibition of AK is mediated by threonine and lysine and varies between the species. The crystal structure of biotechnologically important Clostridium acetobutylicum aspartate kinase (CaAK; E.C. 2.7.2.4; Mw=48,030Da; 437aa; SwissProt: Q97MC0) has been determined to 3Å resolution. CaAK acquires a protein fold similar to the other known structures of AKs despite the low sequence identity (<30%). It is composed of two domains: an N-terminal catalytic domain (kinase) domain and a C-terminal regulatory domain further comprised of two small domains belonging to the ACT domain family. Pairwise comparison of 12 molecules in the asymmetric unit helped to identify the bending regions which are in the vicinity of ATP binding site involved in domain movements between the catalytic and regulatory domains. All 12 CaAK molecules adopt fully open T-state conformation leading to the formation of three tetramers unique among other similar AK structures. On the basis of comparative structural analysis, we discuss tetramer formation based on the large conformational changes in the catalytic domain associated with the lysine binding at the regulatory domains. The structure described herein is homologous to a target in wide-spread pathogenic (toxin producing) bacteria such as Clostridium tetani (64% sequence identity) suggesting the potential of the structure solved here to be applied for modeling drug interactions. CaAK structure may serve as a guide to better understand and engineer lysine biosynthesis for the biotechnology industry.

  9. 120. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    120. Back side technical facilities S.R. radar transmitter & computer building no. 102, section II "foundation & first floor plan" - structural, AS-BLT AW 35-46-04, sheet 65, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  10. 122. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    122. Back side technical facilities S.R. radar transmitter & computer building no. 102, section II "elevations & details" - structural, AS-BLT AW 35-46-04, sheet 73, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  11. 118. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    118. Back side technical facilities S.R. radar transmitter & computer building no. 102, "building sections - sheet I" - architectural, AS-BLT AW 35-46-04, sheet 13, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  12. 121. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    121. Back side technical facilities S.R. radar transmitter & computer building no. 102, section II "sections & elevations" - structural, AS-BLT AW 35-46-04, sheet 72, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  13. 119. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    119. Back side technical facilities S.R. radar transmitter & computer building no. 102, section I "tower plan, sections & details" - structural, AS-BLT AW 35-46-04, sheet 62, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  14. 117. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. Back side technical facilities S.R. radar transmitter & computer building no. 102, "building sections - sheet I" - architectural, AS-BLT AW 35-46-04, sheet 12, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  15. Silencing the HaAK gene by transgenic plant-mediated RNAi impairs larval growth of Helicoverpa armigera.

    PubMed

    Liu, Feng; Wang, Xiao-Dong; Zhao, Yi-Ying; Li, Yan-Jun; Liu, Yong-Chang; Sun, Jie

    2015-01-01

    Insect pests have caused noticeable economic losses in agriculture, and the heavy use of insecticide to control pests not only brings the threats of insecticide resistance but also causes the great pollution to foods and the environment. Transgenic plants producing double-stranded RNA (dsRNA) directed against insect genes have been is currently developed for protection against insect pests. In this study, we used this technology to silence the arginine kinase (AK) gene of Helicoverpa armigera (HaAK), encoding a phosphotransferase that plays a critical role in cellular energy metabolism in invertebrate. Transgenic Arabidopsis plants producing HaAK dsRNA were generated by Agrobacterium-mediated transformation. The maximal mortality rate of 55% was reached when H. armigera first-instar larvae were fed with transgenic plant leaves for 3 days, which was dramatically higher than the 18% mortality recorded in the control group. Moreover, the ingestion of transgenic plants significantly retarded larval growth, and the transcript levels of HaAK were also knocked down by up to 52%. The feeding bioassays further indicated that the inhibition efficiency was correlated with the integrity and concentration of the produced HaAK dsRNA in transgenic plants. These results strongly show that the resistance to H. armigera was improved in transgenic Arabidopsis plants, suggesting that the RNAi targeting of AK has the potential for the control of insect pests.

  16. Computed tomography imaging and angiography - principles.

    PubMed

    Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv

    2016-01-01

    The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology.

  17. Computed Tomography of the Normal Bovine Tarsus.

    PubMed

    Hagag, U; Tawfiek, M; Brehm, W; Gerlach, K

    2016-12-01

    The objective of this study was to provide a detailed multiplanar computed tomographic (CT) anatomic reference for the bovine tarsus. The tarsal regions from twelve healthy adult cow cadavers were scanned in both soft and bone windows via a 16-slice multidetector CT scanner. Tarsi were frozen at -20(o) C and sectioned to 10-mm-thick slices in transverse, dorsal and sagittal planes respecting the imaging protocol. The frozen sections were cleaned and then photographed. Anatomic structures were identified, labelled and compared with the corresponding CT images. The sagittal plane was indispensable for evaluation of bone contours, the dorsal plane was valuable in examination of the collateral ligaments, and both were beneficial for assessment of the tarsal joint articulations. CT images allowed excellent delineation between the cortex and medulla of bones, and the trabecular structure was clearly depicted. The tarsal soft tissues showed variable shades of grey, and the synovial fluid was the lowest attenuated structure. This study provided full assessment of the clinically relevant anatomic structures of the bovine tarsal joint. This technique may be of value when results from other diagnostic imaging techniques are indecisive. Images presented in this study should serve as a basic CT reference and assist in the interpretation of various bovine tarsal pathology.

  18. Computers and Computer Cultures.

    ERIC Educational Resources Information Center

    Papert, Seymour

    1981-01-01

    Instruction using computers is viewed as different from most other approaches to education, by allowing more than right or wrong answers, by providing models for systematic procedures, by shifting the boundary between formal and concrete processes, and by influencing the development of thinking in many new ways. (MP)

  19. Episodic Upwelling of Zooplankton within a Bowhead Whale Feeding Area near Barrow, AK

    DTIC Science & Technology

    2010-09-30

    Whale Feeding Area near Barrow, AK Carin J. Ashjian Department of Biology, MS#33 Woods Hole Oceanographic Institution Woods Hole, MA 02543 phone... whale there and (2) the potential impact of climate change, particularly the ongoing reduction in sea ice and variability in Pacific Water presence...near Barrow, on this feeding environment. This region is a critical feeding area for migrating bowhead whales , particularly during the fall migration

  20. Episodic Upwelling of Zooplankton within a Bowhead Whale Feeding Area Near Barrow, AK

    DTIC Science & Technology

    2011-09-30

    Whale Feeding Area near Barrow, AK Carin J. Ashjian Department of Biology, MS#33 Woods Hole Oceanographic Institution Woods Hole, MA 02543 phone... whale there and (2) the potential impact of climate change, particularly the ongoing reduction in sea ice and variability in Pacific Water presence near...Barrow, on this feeding environment. This region is a critical feeding area for migrating bowhead whales , particularly during the fall migration

  1. The March 1995 superoutburst of the SU Ursae Majoris star AK Cancri: photometry and superhumps.

    NASA Astrophysics Data System (ADS)

    Mennickent, R. E.; Nogami, D.; Kato, T.; Worraker, W.

    1996-11-01

    We present differential photometry of AK Cnc obtained during its March 1995 superoutburst. Superhumps with amplitude of 0.2mag appeared within 4 days after maximum with a period of 0.06749(1)d. This result is used to estimate a likely orbital period of 0.065(2)d and a mass ratio (M_2_/M_1_) of 0.21. Photometric maxima and timings of 26 recorded outbursts imply an average cycle length of 47 days.

  2. Episodic Upwelling of Zooplankton within a Bowhead Whale Feeding Area near Barrow, AK

    DTIC Science & Technology

    2012-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Episodic Upwelling of Zooplankton within a Bowhead Whale...N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Episodic Upwelling of Zooplankton within a Bowhead Whale Feeding Area near Barrow, AK 5a...is associated with changes in climate and ice. 1. Document exchanges of Pacific Water and plankton/krill (acoustic backscatter as a zooplankton

  3. Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT.

    PubMed

    Maintz, David; Burg, Matthias C; Seifarth, Harald; Bunck, Alexander C; Ozgün, Murat; Fischbach, Roman; Jürgens, Kai Uwe; Heindel, Walter

    2009-01-01

    The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary artery stents (19 steel, 6 cobalt-chromium, 2 tantalum, 1 iron, 1 magnesium) were examined in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70 HU). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 400 mAs, 120 kV, rotation time 0.33 s. Image reconstructions were obtained with four different convolution kernels (soft, medium-soft, standard high-resolution, stent-dedicated). To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density, and noise were measured. The stent-dedicated kernel offered best average lumen visualization (54 +/- 8.3%) and most realistic lumen attenuation (222 +/- 44 HU) at the expense of increased noise (23.9 +/- 1.9 HU) compared with standard CTA protocols (p < 0.001 for all). The magnesium stent showed the least artifacts with a lumen visibility of 90%. The majority of stents (79%) exhibited a lumen visibility of 50-59%. Less than half of the stent lumen was visible in only six stents. Stent lumen visibility largely varies depending on the stent type. Magnesium is by far more favorable a stent material with regard to CT imaging when compared with the more common materials steel, cobalt-chromium, or tantalum. The magnesium stent exhibits a lumen visibility of 90%, whereas the majority of the other stents exhibit a lumen visibility of 50-59%.

  4. Voxel-Based Sensitivity of Flat-Panel CT for the Detection of Intracranial Hemorrhage: Comparison to Multi-Detector CT

    PubMed Central

    Frölich, Andreas M.; Buhk, Jan-Hendrik; Fiehler, Jens; Kemmling, Andre

    2016-01-01

    Objectives Flat-panel CT (FPCT) allows cross-sectional parenchymal, vascular and perfusion imaging within the angiography suite, which could greatly facilitate acute stroke management. We hypothesized that FPCT offers equal diagnostic accuracy compared to multi-detector CT (MDCT) as a primary tool to exclude intracranial hemorrhage. Methods 22 patients with intracranial hematomas who had both MDCT and FPCT performed within 24 hours were retrospectively identified. Patients with visible change in hematoma size or configuration were excluded. Two raters independently segmented hemorrhagic lesions. Data sets and corresponding binary lesion maps were co-registered to compare hematoma volume. Diagnostic accuracy of FPCT to detect hemorrhage was calculated from voxel-wise analysis of lesion overlap compared to reference MDCT. Results Mean hematoma size was similar between MDCT (16.2±8.9 ml) and FPCT (16.1±8.6 ml), with near perfect correlation of hematoma sizes between modalities (ρ = 0.95, p<0.001). Sensitivity and specificity of FPCT to detect hemorrhagic voxels was 61.6% and 99.8% for intraventricular hematomas and 67.7% and 99.5% for all other intracranial hematomas. Conclusions In this small sample containing predominantly cases with subarachnoid hemorrhage, FPCT based assessment of hemorrhagic volume in brain yields acceptable accuracy compared to reference MDCT, albeit with a limited sensitivity on a voxel level. Further assessment and improvement of FPCT is necessary before it can be applied as a primary imaging modality to exclude intracranial hemorrhage in acute stroke patients. PMID:27806106

  5. Computer Music

    NASA Astrophysics Data System (ADS)

    Cook, Perry R.

    This chapter covers algorithms, technologies, computer languages, and systems for computer music. Computer music involves the application of computers and other digital/electronic technologies to music composition, performance, theory, history, and the study of perception. The field combines digital signal processing, computational algorithms, computer languages, hardware and software systems, acoustics, psychoacoustics (low-level perception of sounds from the raw acoustic signal), and music cognition (higher-level perception of musical style, form, emotion, etc.).

  6. [Sequence and Structural Analyses of the Complete Genome of Bovine Papillomavirus 2 Genotype Aks-01 Strain from Skin Samples of Cows in Southern Xinjiang, China].

    PubMed

    Zhang, Wanqi; Hu, Jianjun; Yan, Shilei; Huang, Yaojie; Xu, Jianping; Huang, Zhongwu; Zheng, Maoliang; Meng, Ziyan; Li, Yuanyuan; Wang, Na; Wang, Qingqing

    2015-07-01

    To study the complete genomic sequence, genomic characteristics, and genetic variation of the bovine papillomavirus 2 genotype (BPV-2) Aks-01 strain at the molecular level, genotyping of this strain from the skin samples of cows in southern Xinjiang (China) was first detected by the polymerase chain reaction with FAP59/FAP64 primers. Based on the complete genome of the BPV-2 reference strain, specific primers and sequencing primers were designed, and the complete genome of the Aks-01 strain amplified and sequenced. Sequence analyses showed that genotyping of the Aks-01 strain belonged to BPV-2. The Aks-01 strain had the structural characteristics of BPV-2. The 7944-bp full-length genomic sequence of the Aks-01 strain was compiled using DNAStar™. The sequence of the Aks-01 strain had 98% similarity to the reference strain from GenBank. The Aks-01 strain was most closely related to BPV-1 and BPV-13. BPV-2, BPV-1 and BPV-13 were grouped within the genus Deltapapillomavirus. The Aks-01 strain is the first BPV-2 strain reported in southern Xinjiang.

  7. Computer Music

    NASA Astrophysics Data System (ADS)

    Cook, Perry

    This chapter covers algorithms, technologies, computer languages, and systems for computer music. Computer music involves the application of computers and other digital/electronic technologies to music composition, performance, theory, history, and perception. The field combines digital signal processing, computational algorithms, computer languages, hardware and software systems, acoustics, psychoacoustics (low-level perception of sounds from the raw acoustic signal), and music cognition (higher-level perception of musical style, form, emotion, etc.). Although most people would think that analog synthesizers and electronic music substantially predate the use of computers in music, many experiments and complete computer music systems were being constructed and used as early as the 1950s.

  8. iAK692: A genome-scale metabolic model of Spirulina platensis C1

    PubMed Central

    2012-01-01

    Background Spirulina (Arthrospira) platensis is a well-known filamentous cyanobacterium used in the production of many industrial products, including high value compounds, healthy food supplements, animal feeds, pharmaceuticals and cosmetics, for example. It has been increasingly studied around the world for scientific purposes, especially for its genome, biology, physiology, and also for the analysis of its small-scale metabolic network. However, the overall description of the metabolic and biotechnological capabilities of S. platensis requires the development of a whole cellular metabolism model. Recently, the S. platensis C1 (Arthrospira sp. PCC9438) genome sequence has become available, allowing systems-level studies of this commercial cyanobacterium. Results In this work, we present the genome-scale metabolic network analysis of S. platensis C1, iAK692, its topological properties, and its metabolic capabilities and functions. The network was reconstructed from the S. platensis C1 annotated genomic sequence using Pathway Tools software to generate a preliminary network. Then, manual curation was performed based on a collective knowledge base and a combination of genomic, biochemical, and physiological information. The genome-scale metabolic model consists of 692 genes, 837 metabolites, and 875 reactions. We validated iAK692 by conducting fermentation experiments and simulating the model under autotrophic, heterotrophic, and mixotrophic growth conditions using COBRA toolbox. The model predictions under these growth conditions were consistent with the experimental results. The iAK692 model was further used to predict the unique active reactions and essential genes for each growth condition. Additionally, the metabolic states of iAK692 during autotrophic and mixotrophic growths were described by phenotypic phase plane (PhPP) analysis. Conclusions This study proposes the first genome-scale model of S. platensis C1, iAK692, which is a predictive metabolic platform

  9. Long non-coding RNA AK027294 involves in the process of proliferation, migration, and apoptosis of colorectal cancer cells.

    PubMed

    Niu, Hui; Hu, Zhaoyang; Liu, Hui; Hu, Guoliang; Yang, Bo; Wu, Shixiu; Li, Fang

    2016-08-01

    This study is aimed to investigate the differentially expressed long non-coding RNAs (lncRNAs) in colorectal cancer and its potential biological function. Colorectal adenoma is the precancerous lesions of colorectal cancer, so in this study, we used colorectal adenoma as negative control. The global lncRNA expression profile in colorectal cancer and adenoma was evaluated by bioinformatics. The biological functions and potential mechanism of AK027294 were investigated in HCT116, HCT8, and SW480 colorectal cancer cells. A total of 135 lncRNAs were found to be differentially expressed in colorectal cancer and adenoma tissues. Among them, 71 lncRNAs were up-regulated and 64 lncRNAs were down-regulated. Especially, AK027294 was found to be highly expressed in colorectal cancer tissues compared with colorectal adenoma tissues (fold change is 184.5). Our results indicated that AK027294 down-regulation significantly inhibited colorectal cancer cells proliferation and migration, but promoted cell apoptosis (P < 0.05). The potential mechanism of AK027294 might be associated with the regulation of caspase-3, caspase-8, Bcl-2, MMP12, MMP9, and TWIST. The lncRNA expression profile in colorectal cancer suggests lncRNAs may play important roles in the occurrence and progression of colorectal cancer. AK027294 is highly expressed in colorectal cancer and closely correlates with colorectal cells proliferation, migration, and apoptosis.

  10. Usefulness and limitations of postmortem computed tomography in forensic analysis of gunshot injuries: Three case reports.

    PubMed

    Usui, Akihito; Kawasumi, Yusuke; Hosokai, Yoshiyuki; Kozakai, Masataka; Saito, Haruo; Funayama, Masato

    2016-01-01

    Gunshot injury has always been an important field of investigation in postmortem forensic radiology. The localization and retrieval of the bullet and of potentially important fragments are vital to these cases. Using postmortem multidetector-row computed tomography (MDCT) prior to forensic autopsy, we sought to illustrate the importance of this modality in the noninvasive characterization of gunshot wounds. We obtained and analyzed MDCT images in three cases of gunshot wounds (accidental close-range shotgun shooting, suicidal contact gunshot to the head and accidental long-range buckshot shooting). We discuss the value of postmortem MDCT findings in gunshot wound cases by comparing with forensic autopsy findings in Japan, a developing country with miserably low autopsy rate.

  11. Three-dimensional multislice helical computed tomography techniques for canine extra-hepatic portosystemic shunt assessment.

    PubMed

    Bertolini, Giovanna; Rolla, Edoardo C; Zotti, Alessandro; Caldin, Marco

    2006-01-01

    The purpose of the present study was to investigate the feasibility and usefulness of three-dimensional (3D) multislice computed tomography (CT) angiography with maximum intensity projection (MIP) and volume rendering (VR) in six dogs with clinical and sonographic findings suggestive of portosystemic shunt. Furthermore, we aimed to estimate the diameter of the portal vein and shunt vessels. MIP and VR reconstructions were performed for each patient and the origin and insertion of all shunt vessels were detected. In addition, 3D reconstructions allowed excellent depiction of vascular morphology and topography. All diagnoses and vessel measurements were confirmed by surgery. 3D multidetector CT angiography is a promising, noninvasive, and accurate method of evaluating dogs with suspected portosystemic shunts.

  12. Cooling Computers.

    ERIC Educational Resources Information Center

    Birken, Marvin N.

    1967-01-01

    Numerous decisions must be made in the design of computer air conditioning, each determined by a combination of economics, physical, and esthetic characteristics, and computer requirements. Several computer air conditioning systems are analyzed--(1) underfloor supply and overhead return, (2) underfloor plenum and overhead supply with computer unit…

  13. Pygmalion's Computer.

    ERIC Educational Resources Information Center

    Peelle, Howard A.

    Computers have undoubtedly entered the educational arena, mainly in the areas of computer-assisted instruction (CAI) and artificial intelligence, but whether educators should embrace computers and exactly how they should use them are matters of great debate. The use of computers in support of educational administration is widely accepted.…

  14. Development of adaptive noise reduction filter algorithm for pediatric body images in a multi-detector CT

    NASA Astrophysics Data System (ADS)

    Nishimaru, Eiji; Ichikawa, Katsuhiro; Okita, Izumi; Ninomiya, Yuuji; Tomoshige, Yukihiro; Kurokawa, Takehiro; Ono, Yutaka; Nakamura, Yuko; Suzuki, Masayuki

    2008-03-01

    Recently, several kinds of post-processing image filters which reduce the noise of computed tomography (CT) images have been proposed. However, these image filters are mostly for adults. Because these are not very effective in small (< 20 cm) display fields of view (FOV), we cannot use them for pediatric body images (e.g., premature babies and infant children). We have developed a new noise reduction filter algorithm for pediatric body CT images. This algorithm is based on a 3D post-processing in which the output pixel values are calculated by nonlinear interpolation in z-directions on original volumetric-data-sets. This algorithm does not need the in-plane (axial plane) processing, so the spatial resolution does not change. From the phantom studies, our algorithm could reduce SD up to 40% without affecting the spatial resolution of x-y plane and z-axis, and improved the CNR up to 30%. This newly developed filter algorithm will be useful for the diagnosis and radiation dose reduction of the pediatric body CT images.

  15. Investigation of sinonasal anatomy via low-dose multidetector CT examination in chronic rhinosinusitis patients with higher risk for perioperative complications.

    PubMed

    Fraczek, Marcin; Guzinski, Maciej; Morawska-Kochman, Monika; Krecicki, Tomasz

    2017-02-01

    The aim of the study was to compare visualisation of the surgically relevant anatomical structures via low- and standard-dose multidetector CT protocol in patients with chronic rhinosinusitis (CRS) and higher risk for perioperative complications (i.e. presence of bronchial asthma, history of sinus surgery and advanced nasal polyposis). 135 adult CRS patients were divided randomly into standard-dose (120 kVp, 100 mAs) or low-dose CT groups (120 kVp, 45 mAs). The detectability of the vital anatomical structures (anterior ethmoid artery, optic nerve, cribriform plate and lamina papyracea) was scored using a five-point scale (from excellent to unacceptable) by a radiologist and sinus surgeon. Polyp sizes were quantified endoscopically according to the Lildholdt's scale (LS). Olfactory function was tested with the "Sniffin' Sticks" test. On the low-dose CT images, detectability ranged from 2.42 (better than poor) for cribriform plate among anosmic cases to 4.11 (better than good) for lamina papyracea in cases without nasal polyps. Identification of lamina papyracea on low-dose scans was significantly worse in each group and the same was the case with cribriform plates in patients with advanced polyposis and anosmia. Cribriform plates were the most poorly identified (between poor and average) among all the structures on low-dose images. Identification of anterior ethmoid artery (AEA) with reduced dose was insignificantly worse than with standard-dose examination. The AEA was scored as an average-defined structure and was the second weakest visualised. In conclusion, preoperatively, low-dose protocols may not sufficiently visualise the surgically relevant anatomical structures in patients with CRS and bronchial asthma, advanced nasal polyps (LS > 2) and history of sinus surgery. Low mAs value enables comparable detectability of sinonasal landmarks with standard-dose protocols in patients without analysed risk factors. In the context of planned surgery, the current

  16. Pediatric computed tomographic angiography: imaging the cardiovascular system gently.

    PubMed

    Hellinger, Jeffrey C; Pena, Andres; Poon, Michael; Chan, Frandics P; Epelman, Monica

    2010-03-01

    Whether congenital or acquired, timely recognition and management of disease is imperative, as hemodynamic alterations in blood flow, tissue perfusion, and cellular oxygenation can have profound effects on organ function, growth and development, and quality of life for the pediatric patient. Ensuring safe computed tomographic angiography (CTA) practice and "gentle" pediatric imaging requires the cardiovascular imager to have sound understanding of CTA advantages, limitations, and appropriate indications as well as strong working knowledge of acquisition principles and image post processing. From this vantage point, CTA can be used as a useful adjunct along with the other modalities. This article presents a summary of dose reduction CTA methodologies along with techniques the authors have employed in clinical practice to achieve low-dose and ultralow-dose exposure in pediatric CTA. CTA technical principles are discussed with an emphasis on the low-dose methodologies and safe contrast medium delivery strategies. Recommended parameters for currently available multidetector-row computed tomography scanners are summarized alongside recommended radiation and contrast medium parameters. In the second part of the article an overview of pediatric CTA clinical applications is presented, illustrating low-dose and ultra-low dose techniques, with an emphasis on the specific protocols.

  17. Iterative image reconstruction and its role in cardiothoracic computed tomography.

    PubMed

    Singh, Sarabjeet; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Padole, Atul; Lira, Diego; Kalra, Mannudeep K

    2013-11-01

    Revolutionary developments in multidetector-row computed tomography (CT) scanner technology offer several advantages for imaging of cardiothoracic disorders. As a result, expanding applications of CT now account for >85 million CT examinations annually in the United States alone. Given the large number of CT examinations performed, concerns over increase in population-based risk for radiation-induced carcinogenesis have made CT radiation dose a top safety concern in health care. In response to this concern, several technologies have been developed to reduce the dose with more efficient use of scan parameters and the use of "newer" image reconstruction techniques. Although iterative image reconstruction algorithms were first introduced in the 1970s, filtered back projection was chosen as the conventional image reconstruction technique because of its simplicity and faster reconstruction times. With subsequent advances in computational speed and power, iterative reconstruction techniques have reemerged and have shown the potential of radiation dose optimization without adversely influencing diagnostic image quality. In this article, we review the basic principles of different iterative reconstruction algorithms and their implementation for various clinical applications in cardiothoracic CT examinations for reducing radiation dose.

  18. Paleoglaciology of the Ala-Archa and Ak-Shyrak areas, Kyrgyz Tian Shan

    NASA Astrophysics Data System (ADS)

    Blomdin, R.; Beel, C.; Caffee, M. W.; Codilean, A.; Gribenski, N.; Harbor, J.; Heyman, J.; Hattestrand, C.; Ivanov, M.; Kassab, C.; Lifton, N. A.; Petrakov, D.; Rogozhina, I.; Stroeven, A. P.; Usubaliev, R.

    2012-12-01

    We employed detailed glacial geomorphological mapping of the Ala-Archa and Ak-Shyrak areas, Kyrgyz Tian Shan (Shan = Mountains) to build a paleoglaciological reconstruction. These two areas were selected because their glaciers constitute important freshwater reservoirs for downstream communities (the Kyrgyz capital Bishkek, and cities along the Syr Darja which drains towards the Aral Sea, respectively), and because fluctuations in their extent cause both variations in water supply and risks for glacial hazards. Five landform categories were mapped; glacial valleys, marginal moraines, glacial lineations, hummocky terrain, and melt-water channels. These landforms were mapped using a SRTM digital elevation model (DEM) with a 90 m resolution, Landsat 7 ETM+ satellite imagery with a 30 m resolution, Aster GDEM with a 30 m resolution, and Google Earth. This remotely sensed mapping was also checked and complemented by field mapping. The distribution of mapped landforms indicates restricted glaciations, mainly concentrated to the mountain areas. In both ranges marginal moraines extend beyond the furthest extent of glacial valleys. Furthermore, extensive areas of hummocky moraine in Ak-Shyrak extending beyond montane glacial valleys indicate glacial extents into the intermontane basins. Several series of lateral and terminal moraines in the Ala-Archa and Ak-Shyrak ranges have been identified and sampled for cosmogenic nuclide 10Be dating, while associated glaciofluvial sediment was sampled for optically-stimulated luminescence (OSL) and electron spin resonance (ESR) dating. Future work will involve using these samples to build a consistent chronology for glaciation and investigation of contrasts between paleoglaciological reconstructions of valleys within a single range but with different aspects, as well as between ranges. In the final stages of the project we will use intermediate complexity glacier flow models to examine paleoclimatic implications of the observed spatial

  19. Source mechanics for monochromatic icequakes produced during iceberg calving at Columbia Glacier, AK

    USGS Publications Warehouse

    O'Neel, Shad; Pfeffer, W.T.

    2007-01-01

    Seismograms recorded during iceberg calving contain information pertaining to source processes during calving events. However, locally variable material properties may cause signal distortions, known as site and path effects, which must be eliminated prior to commenting on source mechanics. We applied the technique of horizontal/vertical spectral ratios to passive seismic data collected at Columbia Glacier, AK, and found no dominant site or path effects. Rather, monochromatic waveforms generated by calving appear to result from source processes. We hypothesize that a fluid-filled crack source model offers a potential mechanism for observed seismograms produced by calving, and fracture-processes preceding calving.

  20. Computational dosimetry

    SciTech Connect

    Siebert, B.R.L.; Thomas, R.H.

    1996-01-01

    The paper presents a definition of the term ``Computational Dosimetry`` that is interpreted as the sub-discipline of computational physics which is devoted to radiation metrology. It is shown that computational dosimetry is more than a mere collection of computational methods. Computational simulations directed at basic understanding and modelling are important tools provided by computational dosimetry, while another very important application is the support that it can give to the design, optimization and analysis of experiments. However, the primary task of computational dosimetry is to reduce the variance in the determination of absorbed dose (and its related quantities), for example in the disciplines of radiological protection and radiation therapy. In this paper emphasis is given to the discussion of potential pitfalls in the applications of computational dosimetry and recommendations are given for their avoidance. The need for comparison of calculated and experimental data whenever possible is strongly stressed.

  1. Computational Toxicology

    EPA Science Inventory

    Computational toxicology’ is a broad term that encompasses all manner of computer-facilitated informatics, data-mining, and modeling endeavors in relation to toxicology, including exposure modeling, physiologically based pharmacokinetic (PBPK) modeling, dose-response modeling, ...

  2. Cloud Computing

    SciTech Connect

    Pete Beckman and Ian Foster

    2009-12-04

    Chicago Matters: Beyond Burnham (WTTW). Chicago has become a world center of "cloud computing." Argonne experts Pete Beckman and Ian Foster explain what "cloud computing" is and how you probably already use it on a daily basis.

  3. Computer Starters!

    ERIC Educational Resources Information Center

    Instructor, 1983

    1983-01-01

    Instructor's Computer-Using Teachers Board members give practical tips on how to get a classroom ready for a new computer, introduce students to the machine, and help them learn about programing and computer literacy. Safety, scheduling, and supervision requirements are noted. (PP)

  4. Computer Literacy.

    ERIC Educational Resources Information Center

    San Marcos Unified School District, CA.

    THE FOLLOWING IS THE FULL TEXT OF THIS DOCUMENT: After viewing many computer-literacy programs, we believe San Marcos Junior High School has developed a unique program which will truly develop computer literacy. Our hope is to give all students a comprehensive look at computers as they go through their two years here. They will not only learn the…

  5. Distributed Computing.

    ERIC Educational Resources Information Center

    Ryland, Jane N.

    1988-01-01

    The microcomputer revolution, in which small and large computers have gained tremendously in capability, has created a distributed computing environment. This circumstance presents administrators with the opportunities and the dilemmas of choosing appropriate computing resources for each situation. (Author/MSE)

  6. A novel long noncoding RNA AK001796 acts as an oncogene and is involved in cell growth inhibition by resveratrol in lung cancer

    SciTech Connect

    Yang, Qiaoyuan; Xu, Enwu; Dai, Jiabin; Liu, Binbin; Han, Zhiyuan; Wu, Jianjun; Zhang, Shaozhu; Peng, Baoying; Zhang, Yajie; Jiang, Yiguo

    2015-06-01

    Lung cancer is the most common form of cancer throughout the world. The specific targeting of long noncoding RNAs (lncRNAs) by resveratrol opened a new avenue for cancer chemoprevention. In this study, we found that 21 lncRNAs were upregulated and 19 lncRNAs were downregulated in lung cancer A549 cells with 25 μmol/L resveratrol treatment determined by microarray analysis. AK001796, the lncRNA with the most clearly altered expression, was overexpressed in lung cancer tissues and cell lines, but its expression was downregulated in resveratrol-treated lung cancer cells. By monitoring cell proliferation and growth in vitro and tumor growth in vivo, we observed a significant reduction in cell viability in lung cancer cells and a slow growth in the tumorigenesis following AK001796 knockdown. We also found that AK001796 knockdown caused a cell-cycle arrest, with significant increases in the percentage of cells in G{sub 0}/G{sub 1} in lung cancer cells. By using cell cycle pathway-specific PCR arrays, we detected changes in a number of cell cycle-related genes related to lncRNA AK001796 knockdown. We further investigated whether AK001796 participated in the anticancer effect of resveratrol and the results showed that reduced lncRNA AK001796 level potentially impaired the inhibitory effect of resveratrol on cell proliferation. To our knowledge, this is the first study to report the changes in an lncRNA expression profile induced by resveratrol in lung cancer. - Highlights: • LncRNA AK001796 played an oncogenic role in lung carcinogenesis. • LncRNA AK001796 was downregulated in resveratrol-treated lung cancer cells. • LncRNA AK001796 was involved in the inhibition of cell growth by resveratrol.

  7. Portable Computer

    NASA Technical Reports Server (NTRS)

    1985-01-01

    SPOC, a navigation monitoring computer used by NASA in a 1983 mission, was a modification of a commercial computer called GRiD Compass, produced by GRiD Systems Corporation. SPOC was chosen because of its small size, large storage capacity, and high processing speed. The principal modification required was a fan to cool the computer. SPOC automatically computes position, orbital paths, communication locations, etc. Some of the modifications were adapted for commercial applications. The computer is presently used in offices for conferences, for on-site development, and by the army as part of a field communications systems.

  8. Computer sciences

    NASA Technical Reports Server (NTRS)

    Smith, Paul H.

    1988-01-01

    The Computer Science Program provides advanced concepts, techniques, system architectures, algorithms, and software for both space and aeronautics information sciences and computer systems. The overall goal is to provide the technical foundation within NASA for the advancement of computing technology in aerospace applications. The research program is improving the state of knowledge of fundamental aerospace computing principles and advancing computing technology in space applications such as software engineering and information extraction from data collected by scientific instruments in space. The program includes the development of special algorithms and techniques to exploit the computing power provided by high performance parallel processors and special purpose architectures. Research is being conducted in the fundamentals of data base logic and improvement techniques for producing reliable computing systems.

  9. 75 FR 9442 - AK Steel Corporation, Mansfield Works Division, Including On-Site Leased Workers From Time...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-02

    ... Corporation, Mansfield Works Division, including on-site leased workers from Time Customized Staffing... Steel Corporation, Mansfield Works Division, including on-site leased workers from Time Customized... Employment and Training Administration TA-W-71,375 AK Steel Corporation, Mansfield Works Division,...

  10. Using macroalgal δ15N bioassay to detect cruise ship waste water effluent inputs in Skagway, AK

    EPA Science Inventory

    Nitrogen stable isotopes are a powerful tool for tracking sources of N to marine ecosystems. I used green macroalgae as a bioassay organism to evaluate if the δ15N signature of cruise ship waste water effluent (CSWWE) could be detected in Skagway Harbor, AK. Opportunistic green...

  11. 76 FR 36157 - In the Matter of Alaska Industrial X-Ray, Inc., Anchorage, AK; Confirmatory Order Modifying...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-21

    ... Alaska Industrial X-Ray, Inc., Anchorage, AK; Confirmatory Order Modifying License; Effective Immediately I Alaska Industrial X-Ray, Inc. (AIX or Licensee) is the holder of Materials License 50-16084-01... Industrial X-Ray, Inc. (AIX) and the Nuclear Regulatory Commission (NRC) relating to the NRC's letter...

  12. 78 FR 7336 - Safety Zone; Alaska Marine Highway System Port Valdez Ferry Terminal, Port Valdez; Valdez, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-01

    ... Ferry Terminal, Port Valdez; Valdez, AK AGENCY: Coast Guard, DHS. ACTION: Notice of Proposed Rulemaking... Valdez within a 200-yard radius of the Alaska Marine Highway System (AMHS) Port Valdez Ferry Terminal... 200-yards of the AMHS Port Valdez Ferry Terminal whenever an AMHS ferry is underway within 200...

  13. 78 FR 73109 - Radio Broadcasting Services; Benjamin and Cisco, TX; De Beque, CO; Port Lions, AK; Rule and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-05

    ... COMMISSION 47 CFR Part 73 Radio Broadcasting Services; Benjamin and Cisco, TX; De Beque, CO; Port Lions, AK... Commission amends the Table of FM Allotments by removing Channel 221C0 at Port Lions, Alaska; Channel 247C3... two or more FM auctions. No bids were entered for these allotments in Auction 94. It is...

  14. 78 FR 42036 - Radio Broadcasting Services; Port Lions, AK, De Beque, CO, Benjamin, Cisco, Rule, and Shamrock, TX

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-15

    ... COMMISSION 47 CFR Part 73 Radio Broadcasting Services; Port Lions, AK, De Beque, CO, Benjamin, Cisco, Rule...-held permits that have been offered in two FM auctions. No bids were entered for these allotments in the recently completed FM Auction 94 and these allotments are now considered unsold permits....

  15. 33 CFR 165.1712 - Safety Zones; Annual Independence Day Firework Displays, Skagway, Haines, and Wrangell, AK.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Day Firework Displays, Skagway, Haines, and Wrangell, AK. 165.1712 Section 165.1712 Navigation and... Areas Seventeenth Coast Guard District § 165.1712 Safety Zones; Annual Independence Day Firework... zones: (1) All navigable waters of Taiya Inlet within a 300-yard radius of the fireworks launching...

  16. 33 CFR 165.1712 - Safety Zones; Annual Independence Day Firework Displays, Skagway, Haines, and Wrangell, AK.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Day Firework Displays, Skagway, Haines, and Wrangell, AK. 165.1712 Section 165.1712 Navigation and... Areas Seventeenth Coast Guard District § 165.1712 Safety Zones; Annual Independence Day Firework... zones: (1) All navigable waters of Taiya Inlet within a 300-yard radius of the fireworks launching...

  17. Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.; Mitchell, Mark A.

    2016-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon the solvent AsahiKlin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

  18. Parameters influencing Agrobacterium-mediated transformation system in safflower genotypes AKS-207 and PKV Pink.

    PubMed

    Dhumale, Dipti Raghunath; Shingote, Prashant Raghunath; Dudhare, Mahendra Shankarrao; Jadhav, Pravin Vishwanath; Kale, Prashant Bhaskar

    2016-12-01

    Shoot regeneration in safflower (Carthamus tinctorius 'AKS 207' and 'PKV Pink') genetically transformed using Agrobacterium was used for assessing various constraints to the efficiency of transformation including infection period, virulence induction medium, co-cultivation period, bacterial titre, selection regime, and the natural phenolic compound acetosyringone. Transformation frequency was promising with 8-10-day-old cotyledonary leaf explants. Therefore, explants of that age cultured on Agrobacterium minimal medium (AB) containing 100 µM acetosyringone were infected with Agrobacterium (cell titre 0.5 OD600nm) for 15 min followed by 48 h of co-cultivation on kanamycin-enriched medium (50 mg/L). Transformation of the shoots was confirmed using β-glucuronidase (GUS) histochemical assay and polymerase chain reaction (PCR). With the transformation protocol thus optimized, the transformation frequency as determined using GUS assays was 54.0 % for AKS 207 and 47.6 % for PKV Pink. The corresponding figures using PCR were 27.0 and 33.3 %. The transformed shoots required 10-14 weeks of culture initiation but produced very few roots.

  19. A Disk-based Dynamical Mass Estimate for the Young Binary AK Sco

    NASA Astrophysics Data System (ADS)

    Czekala, I.; Andrews, S. M.; Jensen, E. L. N.; Stassun, K. G.; Torres, G.; Wilner, D. J.

    2015-06-01

    We present spatially and spectrally resolved Atacama Large Millimeter/submillimeter Array (ALMA) observations of gas and dust in the disk orbiting the pre-main sequence (pre-MS) binary AK Sco. By forward-modeling the disk velocity field traced by CO J = 2-1 line emission, we infer the mass of the central binary, {M}*=2.49+/- 0.10 {M}⊙ , a new dynamical measurement that is independent of stellar evolutionary models. Assuming the disk and binary are co-planar within ˜2°, this disk-based binary mass measurement is in excellent agreement with constraints from radial velocity monitoring of the combined stellar spectra. These ALMA results are also compared with the standard approach of estimating masses from the location of the binary in the Hertzsprung-Russell diagram, using several common pre-MS model grids. These models predict stellar masses that are marginally consistent with our dynamical measurement (at ˜2σ), but are systematically high (by ˜10%). These same models consistently predict an age of 18 ± 1 Myr for AK Sco, in line with its membership in the Upper Centaurus-Lupus association but surprisingly old for it to still host a gas-rich disk. As ALMA accumulates comparable data for large samples of pre-MS stars, the methodology employed here to extract a dynamical mass from the disk rotation curve should prove extraordinarily useful for efforts to characterize the fundamental parameters of early stellar evolution.

  20. Biosorption of lead using Bacillus badius AK strain isolated from compost of green waste (water hyacinth).

    PubMed

    Vishan, Isha; Sivaprakasam, Senthilkumar; Kalamdhad, Ajay

    2017-03-13

    The bacterial strain Bacillus badius AK isolated from water hyacinth compost was investigated for biosorption characteristics in Pb(II) removal. Batch mode experiments depicted the optimum conditions for biosorption as pH at 4, the temperature of 30°C, 150 rpm of the rotational speed at biomass concentration of 20 mL with 1.7 × 10(16) colony forming unit per milliliter (CFU/mL) value, at 100-150 mg/L concentration of Pb(II). The bacterial biomass was used in its native and non-pretreated state, unlike the dried, freeze-dried or chemically treated biomass. The biosorption followed pseudo-second-order kinetics and isotherm fitted well to the Langmuir model. Maximum Pb(II) biosorption was observed at 1.7 × 10(16) CFU/mL. Influence of Pb(II) on the growth of bacterial biomass was examined by fitting the monod's model. Specific growth rate and maximum specific growth rate of B. badius AK was observed as 0.05 and 2.54 h(-1), respectively; biomass yield coefficient was 11.81. The results indicated that bacterial biomass was efficient, robust and cheaper biosorbent for removal of Pb(II).

  1. Transcription factor Oct4 promotes osteosarcoma by regulating lncRNA AK055347

    PubMed Central

    Fan, Hongwu; Liu, Guangyao; Zhao, Changfu; Li, Xuefeng; Yang, Xiaoyu

    2017-01-01

    Osteosarcoma is the most common primary bone tumor in children and adolescents, typically presenting with a poor prognosis. Octamer-binding transcription factor 4 (Oct4) protein, encoded by the POU class 5 homeobox 1 gene, is important in maintaining self-renewal of pluripotent stem cells, and is closely associated with cancer. However, its role in osteosarcoma remains to be elucidated. The present study observed Oct4 was markedly increased in osteosarcoma cell lines and in human osteosarcoma tissue samples. Following Oct4 downregulation by small interfering RNA (siRNA) in osteosarcoma F5M2 cells, the cells exhibited significant decreases in proliferation and invasion ability, and an increase in cell apoptosis. Notably, downregulation of Oct4 decreased the expression of AK055347, a newly identified long noncoding RNA (lncRNA) in human tissues. The downregulation of AK055347 by siRNA resulted in a significant suppressive effect on proliferative and invasive ability, and promotion of cell apoptosis in osteosarcoma cells. Thus, the current study suggests Oct4 exerts a promoting effect in osteosarcoma, and identifies a novel lncRNA in osteosarcoma progression. PMID:28123573

  2. Mapping the magnetospheric structure at outburst of the pre-main sequence close binary AK Sco

    NASA Astrophysics Data System (ADS)

    Gomez De Castro, Ana

    2013-10-01

    Pre-main sequence {PMS} binaries are surrounded by circumbinary disks from which matter falls onto both components. The material dragged from the circumbinary disk flows onto each star through independent streams channelled by the variable gravitational field. The action of the bar-like potential is most prominent in high eccentricity systems made of two equal mass stars. AK Sco is a unique PMS system composed of two F5 stars that get as close as 11.3 stellar radii at periastron {e=0.47}. AK Sco is an ideal laboratory to study matter infall in binaries and its role in orbit circularization. Our team has reported recently, the discovery of an unexpected 1.3mHz ultra low frequency {ULF} oscillation in the ultraviolet light curve at periastron passage. The oscillation lasted 0.6% of the orbital period. According to our numerical simulations, the cirscumstellar structures get in contact at periastron producing an accretion outburst that triggered of the oscillation. If confirmed, this would unveil a new mechanism for angular momentum loss during pre-main sequence evolution and a new type of interacting binary. The objective of this project is to identify the source of the oscillation and the physical structure of the accretion flow before, during and after the oscillation is triggered. Since the accretion flow radiates in the ultraviolet range, this study requires an ultraviolet {UV} spectroscopic monitoring.

  3. Production of S-(+)-ibuprofen from a nitrile compound by Acinetobacter sp. strain AK226.

    PubMed Central

    Yamamoto, K; Ueno, Y; Otsubo, K; Kawakami, K; Komatsu, K

    1990-01-01

    S-(+)-2-(4'-Isobutylphenyl)propionic acid [S-(+)-ibuprofen] was produced from racemic 2-(4'-isobutylphenyl)propionitrile (Ibu-CN) by an isolated bacterial strain, Acinetobacter sp. strain AK226. Ammonium acetate, acetonitrile, or n-butyronitrile as a carbon source in the culture medium was effective for bacterial growth and induction of this activity. The optimum pH of the reaction was around 8.0. S-(+)-Ibuprofen formed from Ibu-CN by resting cells was present in a 95% enantiomeric excess. Acinetobacter sp. strain AK226 appeared to possess a nitrilase for Ibu-CN because 2-(4'-isobutylphenyl)propionamide was not detected in the reaction mixture and 2-(4'-isobutylphenyl)propionamide was not hydrolyzed to S-(+)-ibuprofen. Since S-(+)-ibuprofen was preferentially produced while the R enantiomer of Ibu-CN was left almost intact over the time course of the reaction, the putative nitrilase appeared to be highly specific for the S enantiomer of Ibu-CN. PMID:2285318

  4. Birth of an ‘Asian cool’ reference genome: AK1

    PubMed Central

    Kim, Changhoon

    2016-01-01

    The human reference genome, maintained by the Genome Reference Consortium, is conceivably the most complete genome assembly ever, since its first construction. It has continually been improved by incorporating corrections made to the previous assemblies, thanks to various technological advances. Many currently-ongoing population sequencing projects have been based on this reference genome, heightening hopes of the development of useful medical applications of genomic information, thanks to the recent maturation of high-throughput sequencing technologies. However, just one reference genome does not fit all the populations across the globe, because of the large diversity in genomic structures and technical limitations inherent to short read sequencing methods. The recent success in de novo construction of the highly contiguous Asian diploid genome AK1, by combining single molecule technologies with routine sequencing data without resorting to traditional clone-by-clone sequencing and physical mapping, reveals the nature of genomic structure variation by detecting thousands of novel structural variations and by finally filling in some of the prior gaps which had persistently remained in the current human reference genome. Now it is expected that the AK1 genome, soon to be paired with more upcoming de novo assembled genomes, will provide a chance to explore what it is really like to use ancestry-specific reference genomes instead of hg19/hg38 for population genomics. This is a major step towards the furthering of genetically-based precision medicine. PMID:27881215

  5. Characterization of a GHF45 cellulase, AkEG21, from the common sea hare Aplysia kurodai

    NASA Astrophysics Data System (ADS)

    Rahman, Mohammad; Inoue, Akira; Ojima, Takao

    2014-08-01

    The common sea hare Aplysia kurodai is known to be a good source for the enzymes degrading seaweed polysaccharides. Recently four cellulases, i.e., 95 kDa, 66 kDa, 45 kDa and 21 kDa enzymes, were isolated from A. kurodai (Tsuji et al., PLoS ONE, 8, e65418, 2013). The former three cellulases were regarded as glycosyl-hydrolase-family 9 (GHF9) enzymes, while the 21 kDa cellulase was suggested to be a GHF45 enzyme. The 21 kDa cellulase was significantly heat stable, and appeared to be advantageous in performing heterogeneous expression and protein-engineering study. In the present study, we determined some enzymatic properties of the 21 kDa cellulase and cloned its cDNA to provide the basis for the protein engineering study of this cellulase. The purified 21 kDa enzyme, termed AkEG21 in the present study, hydrolyzed carboxymethyl cellulose with an optimal pH and temperature at 4.5 and 40oC, respectively. AkEG21 was considerably heat-stable, i.e., it was not inactivated by the incubation at 55oC for 30 min. AkEG21 degraded phosphoric-acid-swollen cellulose producing cellotriose and cellobiose as major end products but hardly degraded oligosaccharides smaller than tetrasaccharide. This indicated that AkEG21 is an endolytic ?-1,4-glucanase (EC 3.2.1.4). A cDNA of 1,013 bp encoding AkEG21 was amplified by PCR and the amino-acid sequence of 197 residues was deduced. The sequence comprised the initiation Met, the putative signal peptide of 16 residues for secretion and the catalytic domain of 180 residues, which lined from the N-terminus in this order. The sequence of the catalytic domain showed 47-62% amino-acid identities to those of GHF45 cellulases reported in other mollusks. Both the catalytic residues and the N-glycosylation residues known in other GHF45 cellulases were conserved in AkEG21. Phylogenetic analysis for the amino-acid sequences suggested the close relation between AkEG21 and fungal GHF45 cellulases.

  6. Characterization of a GHF45 cellulase, AkEG21, from the common sea hare Aplysia kurodai.

    PubMed

    Rahman, Mohammad M; Inoue, Akira; Ojima, Takao

    2014-01-01

    The common sea hare Aplysia kurodai is known to be a good source for the enzymes degrading seaweed polysaccharides. Recently four cellulases, i.e., 95, 66, 45, and 21 kDa enzymes, were isolated from A. kurodai (Tsuji et al., 2013). The former three cellulases were regarded as glycosyl-hydrolase-family 9 (GHF9) enzymes, while the 21 kDa cellulase was suggested to be a GHF45 enzyme. The 21 kDa cellulase was significantly heat stable, and appeared to be advantageous in performing heterogeneous expression and protein-engineering study. In the present study, we determined some enzymatic properties of the 21 kDa cellulase and cloned its cDNA to provide the basis for the protein engineering study of this cellulase. The purified 21 kDa enzyme, termed AkEG21 in the present study, hydrolyzed carboxymethyl cellulose with an optimal pH and temperature at 4.5 and 40°C, respectively. AkEG21 was considerably heat-stable, i.e., it was not inactivated by the incubation at 55°C for 30 min. AkEG21 degraded phosphoric-acid-swollen cellulose producing cellotriose and cellobiose as major end products but hardly degraded oligosaccharides smaller than tetrasaccharide. This indicated that AkEG21 is an endolytic β-1,4-glucanase (EC 3.2.1.4). A cDNA of 1013 bp encoding AkEG21 was amplified by PCR and the amino-acid sequence of 197 residues was deduced. The sequence comprised the initiation Met, the putative signal peptide of 16 residues for secretion and the catalytic domain of 180 residues, which lined from the N-terminus in this order. The sequence of the catalytic domain showed 47-62% amino-acid identities to those of GHF45 cellulases reported in other mollusks. Both the catalytic residues and the N-glycosylation residues known in other GHF45 cellulases were conserved in AkEG21. Phylogenetic analysis for the amino-acid sequences suggested the close relation between AkEG21 and fungal GHF45 cellulases.

  7. Characterization of a GHF45 cellulase, AkEG21, from the common sea hare Aplysia kurodai

    PubMed Central

    Rahman, Mohammad M.; Inoue, Akira; Ojima, Takao

    2014-01-01

    The common sea hare Aplysia kurodai is known to be a good source for the enzymes degrading seaweed polysaccharides. Recently four cellulases, i.e., 95, 66, 45, and 21 kDa enzymes, were isolated from A. kurodai (Tsuji et al., 2013). The former three cellulases were regarded as glycosyl-hydrolase-family 9 (GHF9) enzymes, while the 21 kDa cellulase was suggested to be a GHF45 enzyme. The 21 kDa cellulase was significantly heat stable, and appeared to be advantageous in performing heterogeneous expression and protein-engineering study. In the present study, we determined some enzymatic properties of the 21 kDa cellulase and cloned its cDNA to provide the basis for the protein engineering study of this cellulase. The purified 21 kDa enzyme, termed AkEG21 in the present study, hydrolyzed carboxymethyl cellulose with an optimal pH and temperature at 4.5 and 40°C, respectively. AkEG21 was considerably heat-stable, i.e., it was not inactivated by the incubation at 55°C for 30 min. AkEG21 degraded phosphoric-acid-swollen cellulose producing cellotriose and cellobiose as major end products but hardly degraded oligosaccharides smaller than tetrasaccharide. This indicated that AkEG21 is an endolytic β-1,4-glucanase (EC 3.2.1.4). A cDNA of 1013 bp encoding AkEG21 was amplified by PCR and the amino-acid sequence of 197 residues was deduced. The sequence comprised the initiation Met, the putative signal peptide of 16 residues for secretion and the catalytic domain of 180 residues, which lined from the N-terminus in this order. The sequence of the catalytic domain showed 47–62% amino-acid identities to those of GHF45 cellulases reported in other mollusks. Both the catalytic residues and the N-glycosylation residues known in other GHF45 cellulases were conserved in AkEG21. Phylogenetic analysis for the amino-acid sequences suggested the close relation between AkEG21 and fungal GHF45 cellulases. PMID:25147784

  8. A 64-slice multi-detector CT scan could evaluate the change of the left atrial appendage thrombi of the atrial fibrillation patient, which was reduced by warfarin therapy.

    PubMed

    Takeuchi, Hidekazu

    2011-08-19

    Curable cause of stroke is the left atrial appendage (LAA) thrombi of atrial fibrillation (AF) patients. Some AF patients have the LAA thrombi. It is very important to cure AF patients by warfarin. Transoesophageal echocardiography (TOE) is the usual clinical tool to detect the LAA thrombi. Recently, a 64-slice multi-detector CT (64-MDCT) scan enables us to display the LAA thrombi more easily than TOE. I reported a case that a 64-MDCT scan had been used successfully in displaying the change of the LAA thrombi reduced by warfarin therapy. The size of the LAA thrombi was reduced from 25.2 mm × 19.3 mm (figure 1) to 22.1 mm × 14.8 mm (figure 2) after the 3-month warfarin therapy. It was useful to estimate the LAA thrombi by a 64-MDCT scan to estimate LAA thrombi itself and the change of LAA thrombi to evaluate the effectiveness of warfarin therapy.

  9. Computer-based route-definition system for peripheral bronchoscopy.

    PubMed

    Graham, Michael W; Gibbs, Jason D; Higgins, William E

    2012-04-01

    Multi-detector computed tomography (MDCT) scanners produce high-resolution images of the chest. Given a patient's MDCT scan, a physician can use an image-guided intervention system to first plan and later perform bronchoscopy to diagnostic sites situated deep in the lung periphery. An accurate definition of complete routes through the airway tree leading to the diagnostic sites, however, is vital for avoiding navigation errors during image-guided bronchoscopy. We present a system for the robust definition of complete airway routes suitable for image-guided bronchoscopy. The system incorporates both automatic and semiautomatic MDCT analysis methods for this purpose. Using an intuitive graphical user interface, the user invokes automatic analysis on a patient's MDCT scan to produce a series of preliminary routes. Next, the user visually inspects each route and quickly corrects the observed route defects using the built-in semiautomatic methods. Application of the system to a human study for the planning and guidance of peripheral bronchoscopy demonstrates the efficacy of the system.

  10. Developing Computation

    ERIC Educational Resources Information Center

    McIntosh, Alistair

    2004-01-01

    In this article, the author presents the results of a state project that focused on the effect of developing informal written computation processes through Years 2-4. The "developing computation" project was conducted in Tasmania over the two years 2002-2003 and involved nine schools: five government schools, two Catholic schools, and…

  11. Computing Life

    ERIC Educational Resources Information Center

    National Institute of General Medical Sciences (NIGMS), 2009

    2009-01-01

    Computer advances now let researchers quickly search through DNA sequences to find gene variations that could lead to disease, simulate how flu might spread through one's school, and design three-dimensional animations of molecules that rival any video game. By teaming computers and biology, scientists can answer new and old questions that could…

  12. Computer News

    ERIC Educational Resources Information Center

    Science Activities: Classroom Projects and Curriculum Ideas, 2007

    2007-01-01

    This article presents several news stories about computers and technology. (1) Applied Science Associates of Narragansett, Rhode Island is providing computer modeling technology to help locate the remains to the USS Bonhomme Richard, which sank in 1779 after claiming a Revolutionary War victory. (2) Whyville, the leading edu-tainment virtual world…

  13. Grid Computing

    NASA Astrophysics Data System (ADS)

    Foster, Ian

    2001-08-01

    The term "Grid Computing" refers to the use, for computational purposes, of emerging distributed Grid infrastructures: that is, network and middleware services designed to provide on-demand and high-performance access to all important computational resources within an organization or community. Grid computing promises to enable both evolutionary and revolutionary changes in the practice of computational science and engineering based on new application modalities such as high-speed distributed analysis of large datasets, collaborative engineering and visualization, desktop access to computation via "science portals," rapid parameter studies and Monte Carlo simulations that use all available resources within an organization, and online analysis of data from scientific instruments. In this article, I examine the status of Grid computing circa 2000, briefly reviewing some relevant history, outlining major current Grid research and development activities, and pointing out likely directions for future work. I also present a number of case studies, selected to illustrate the potential of Grid computing in various areas of science.

  14. Computational Pathology

    PubMed Central

    Louis, David N.; Feldman, Michael; Carter, Alexis B.; Dighe, Anand S.; Pfeifer, John D.; Bry, Lynn; Almeida, Jonas S.; Saltz, Joel; Braun, Jonathan; Tomaszewski, John E.; Gilbertson, John R.; Sinard, John H.; Gerber, Georg K.; Galli, Stephen J.; Golden, Jeffrey A.; Becich, Michael J.

    2016-01-01

    Context We define the scope and needs within the new discipline of computational pathology, a discipline critical to the future of both the practice of pathology and, more broadly, medical practice in general. Objective To define the scope and needs of computational pathology. Data Sources A meeting was convened in Boston, Massachusetts, in July 2014 prior to the annual Association of Pathology Chairs meeting, and it was attended by a variety of pathologists, including individuals highly invested in pathology informatics as well as chairs of pathology departments. Conclusions The meeting made recommendations to promote computational pathology, including clearly defining the field and articulating its value propositions; asserting that the value propositions for health care systems must include means to incorporate robust computational approaches to implement data-driven methods that aid in guiding individual and population health care; leveraging computational pathology as a center for data interpretation in modern health care systems; stating that realizing the value proposition will require working with institutional administrations, other departments, and pathology colleagues; declaring that a robust pipeline should be fostered that trains and develops future computational pathologists, for those with both pathology and non-pathology backgrounds; and deciding that computational pathology should serve as a hub for data-related research in health care systems. The dissemination of these recommendations to pathology and bioinformatics departments should help facilitate the development of computational pathology. PMID:26098131

  15. Computer Insecurity.

    ERIC Educational Resources Information Center

    Wilson, David L.

    1994-01-01

    College administrators recently appealed to students and faculty to change their computer passwords after security experts announced that tens of thousands had been stolen by computer hackers. Federal officials are investigating. Such attacks are not uncommon, but the most effective solutions are either inconvenient or cumbersome. (MSE)

  16. Computational astrophysics

    NASA Technical Reports Server (NTRS)

    Miller, Richard H.

    1987-01-01

    Astronomy is an area of applied physics in which unusually beautiful objects challenge the imagination to explain observed phenomena in terms of known laws of physics. It is a field that has stimulated the development of physical laws and of mathematical and computational methods. Current computational applications are discussed in terms of stellar and galactic evolution, galactic dynamics, and particle motions.

  17. Computer Recreations.

    ERIC Educational Resources Information Center

    Dewdney, A. K.

    1989-01-01

    Discussed are three examples of computer graphics including biomorphs, Truchet tilings, and fractal popcorn. The graphics are shown and the basic algorithm using multiple iteration of a particular function or mathematical operation is described. An illustration of a snail shell created by computer graphics is presented. (YP)

  18. Computer Graphics.

    ERIC Educational Resources Information Center

    Halpern, Jeanne W.

    1970-01-01

    Computer graphics have been called the most exciting development in computer technology. At the University of Michigan, three kinds of graphics output equipment are now being used: symbolic printers, line plotters or drafting devices, and cathode-ray tubes (CRT). Six examples are given that demonstrate the range of graphics use at the University.…

  19. I, Computer

    ERIC Educational Resources Information Center

    Barack, Lauren

    2005-01-01

    What child hasn't chatted with friends through a computer? But chatting with a computer? Some Danish scientists have literally put a face on their latest software program, bringing to virtual life storyteller Hans Christian Andersen, who engages users in actual conversations. The digitized Andersen resides at the Hans Christian Andersen Museum in…

  20. Autophosphorylation at Thr279 of Entamoeba histolytica atypical kinase EhAK1 is required for activity and regulation of erythrophagocytosis

    PubMed Central

    Mansuri, M Shahid; Babuta, Mrigya; Ali, Mohammad Sabir; Bharadwaj, Ravi; jhingan, Gagan Deep; Gourinath, Samudrala; Bhattacharya, Sudha; Bhattacharya, Alok

    2016-01-01

    Phagocytosis plays a key role in survival and pathogenicity of Entamoeba histolytica. We have recently demonstrated that an atypical kinase EhAK1 is involved in phagocytosis in this parasite. It is recruited to the phagocytic cups through interaction with EhCaBP1. EhAK1 manipulates actin dynamics by multiple mechanisms including phosphorylation of G-actin. Biochemical analysis showed that EhAK1 is a serine/threonine kinase with broad ion specificity and undergoes multiple trans-autophosphorylation. Three autophosphorylation sites were identified by mass spectrometry. Out of these Thr279 appears to be involved in both autophosphorylation as well as substrate phosphorylation. Over expression of the mutant Thr279A inhibited erythrophagocytosis showing dominant negative phenotype. Multiple alignments of different kinases including alpha kinases displayed conserved binding sites that are thought to be important for function of the protein. Mutation studies demonstrated the importance of some of these binding sites in kinase activity. Binding studies with fluorescent-ATP analogs supported our prediction regarding ATP binding site based on sequence alignment. In conclusion, EhAK1 has multiple regulatory features and enrichment of EhAK1 at the site of phagocytosis stimulates trans-autophosphorylation reaction that increases kinase activity resulting in enhanced actin dynamics and phagocytosis. Some of the properties of EhAK1 are similar to that seen in alpha kinases. PMID:26739245

  1. Salt bridge residues between I-Ak dimer of dimers alpha-chains modulate antigen presentation.

    PubMed

    Yadati, S; Nydam, T; Demian, D; Wade, T K; Gabriel, J L; Barisas, B G; Wade, W F

    1999-03-15

    Class II dimers of dimers are predicted to have functional significance in antigen presentation. The putative contact amino acids of the I-Ak class II dimer of dimers have been identified by molecular modeling based on the DR1 crystal structure (Nydam et al., Int. Immunol. 10, 1237,1998). We have previously reported the role in antigen presentation of dimer of dimers contact amino acids located in the C-terminal domains of the alpha- and beta-chains of class II. Our calculations show that residues Ealpha89 and Ralpha145 in the alpha2-domain form an inter alpha-chain salt bridge between pairs of alphabeta-heterodimers. Other residues, Qalpha92 and Nalpha115, may be involved in close association in that part of the alpha-chain. We investigated the role of these amino acids on class II expression and antigen presentation. Class II composed of an Ealpha89K substituted alpha-chain paired with a wt beta-chain exhibited inhibited antigen presentation and expression of alpha-chain serologic epitopes. In contrast, mutation of Ralpha145E had less affect on antigen presentation and did not affect I-Ak serologic epitopes. Interchanging charges of the salt bridge residues by expressing both Ralpha145E and Ealpha89K on the same chain obviated the large negative effect of the Ealpha89K mutation on antigen presentation but not on the serologic epitopes. Our results are similar for those reported for mutation of DR3's inter-chain salt bridge with the exception that double mutants did not moderate the DR3 defect. Interestingly, the amino acids differences between I-A and DR change the location of the inter-chain salt bridges. In DR1 these residues are located at positions Ealpha88 and Kalpha111; in I-Ak these residues are located at position Ealpha89 and Ralpha145. Inter alpha-chain salt bridges are thus maintained in various class II molecules by amino acids located in different parts of the alpha2-domain. This conservation of structure suggests that considerable functional

  2. AK Sco: evidence of tide driven filling of the inner gap in the circumbinary disk

    NASA Astrophysics Data System (ADS)

    Gomez de Castro, Ana I.; Lopez-Santiago, Javier; Talavera, Antonio; Sytov, A. Yu.; Bisikalo, Dmitri

    2013-07-01

    AK Sco stands out among pre-main sequence binaries because of its prominent ultraviolet excess, the high eccentricity of its orbit and the strong tides driven by it. AK Sco is made of two F5 type stars that get as close as 11R* at periastron passage. The presence of a dense (ne ~ 1011 cm-3) extended envelope has been unveiled recently. In this article, we report the results from a XMM-Newton based, monitoring of the system. We show that at periastron, X-ray and UV fluxes are enhanced by a factor of ~3 with respect to the apastron values. The X-ray radiation is produced in an optically thin plasma with T~6.4 MK and it is found that the NH column rises from 0.35 1021 cm-2 at periastron to 1.11 1021 cm-2 at apastron, in good agreement with previous polarimetric observations. The UV emission detected in the OM band seems to be caused by the reprocessing of the high energy magnetospheric radiation on the circumstellar material. Moreover, further evidence of the strong magnetospheric disturbances is provided by the detection of line broadening of 279 km s-1 in the N V line with HST/STIS. Numerical simulations of the mass flow from the circumbinary disk to the components have been carried out. They provide a consistent scenario to interpret AK Sco observations. We show that the eccentric orbit acts like a gravitational piston. At apastron, matter is dragged efficiently from the inner disk border, filling the inner gap and producing accretion streams that end as ring-like structures around each component of the system. At periastron, the ring-like structures get in contact, leading to angular momentum annihilation, and thus producing an accretion outburst. These results are published in Gómez de Castro et al. 2013, ApJ, 766, 62 We have also discovered a 780 s period oscillation in the UV continuum light curve triggered at periastron passage (Gómez de Castro, Lopez-Santiago & Talavera, 2013, MNRAS, 429, L1).

  3. Cloud Computing

    DTIC Science & Technology

    2009-11-12

    Eucalyptus Systems • Provides an open-source application that can be used to implement a cloud computing environment on a datacenter • Trying to establish an...Summary Cloud Computing is in essence an economic model • It is a different way to acquire and manage IT resources There are multiple cloud providers...edgeplatform.html • Amazon Elastic Compute Cloud (EC2): http://aws.amazon.com/ec2/ • Amazon Simple Storage Solution (S3): http://aws.amazon.com/s3/ • Eucalyptus

  4. Optical computing.

    NASA Technical Reports Server (NTRS)

    Stroke, G. W.

    1972-01-01

    Applications of the optical computer include an approach for increasing the sharpness of images obtained from the most powerful electron microscopes and fingerprint/credit card identification. The information-handling capability of the various optical computing processes is very great. Modern synthetic-aperture radars scan upward of 100,000 resolvable elements per second. Fields which have assumed major importance on the basis of optical computing principles are optical image deblurring, coherent side-looking synthetic-aperture radar, and correlative pattern recognition. Some examples of the most dramatic image deblurring results are shown.

  5. Time-Averaged and Time-Dependent Computations of Isothermal Flowfields in a Centerbody Combustor.

    DTIC Science & Technology

    1984-12-01

    7.00 cm. The mesh is cons trtie tedI wi thca J1)i step sizes, AK and Ar to provide a - finer miesh at the near-wall rog ions, of the cfntorbody and the...2252 F/G 28/4 NL E _13 8 EE E D IEEENDEEOPTAIOSF * 11111- 3. 2A 1114-.2 11112- MICROCOPY RESOLUTION TEST CHART NATIONAL FLIRLAU OF SINALq163 A ...1.% . :. . - o%-. ., N (V) o TIME-AVERAGED AND TIME-DEPENDENT COMPUTATIONS OF isO’HERMAL FLOWFIELIDS IN A CENTERBODY

  6. Tectonic geomorphology of a large normal fault: Akşehir fault, SW Turkey

    NASA Astrophysics Data System (ADS)

    Topal, Savaş; Keller, Edward; Bufe, Aaron; Koçyiğit, Ali

    2016-04-01

    In order to better understand the activity of the Akşehir normal fault in SW Turkey and the associated seismic hazard, we investigated the tectonic geomorphology of a 60-km stretch of the 100-km-long Akşehir fault block. The fault can be separated into seven geomorphic segments (1 to 7 from NW to SE) along the mountain front. Segment length varies from about 9 to 14 km, and relief of the horst block varies from about 0.6 km in the SE to 1.0 km in the NW. Analysis of the tectonic geomorphology of 32 drainage basins and mountain front facets using a combination of geomorphic indices reveals a general pattern of high slip rates in the northern and central segments and low slip rates in the southern, probably older, segments. We show that mountain front sinuosity varies from about 1.1 to 1.4 on segments S1-S6 to 2.4 on segment S7, suggesting that the six northern segments are more active than the southernmost segment. Similarly, χ analysis and slope-area analysis of streams reveal a pattern of steepest channels draining the central and northern segments of the horst. The ratio of valley floor width to valley height varies from 0.2 to 0.6, which are typical values for tectonically active mountain fronts; and alluvial fans along segments S1, S2, and S4 are back-tilted. Finally, we show that (1) shapes of the ~ 100-900m high mountain front facets are mostly triangular (~ 80%) and partly trapezoidal (~ 20%); (2) facet slopes range from 6 to 22°; (3) facets at the NW and SE segment ends are larger than the intervening facets; and (4) steepest facets occur along the central segments. Uplift rates estimated from the slope of mountain front facets range from about 0.06 m/ky on the southernmost fault segment (S7) to 0.23 m/ky on the more central S5 and 0.16 m/ky on the northern segment (S1). The estimated pattern of uplift is consistent with the pattern of geomorphic indices. The vertical relief of the facets suggests that uplift of the mountain front initiated in the late

  7. The genome sequence of Desulfatibacillum alkenivorans AK-01: a blueprint for anaerobic alkane oxidation.

    PubMed

    Callaghan, A V; Morris, B E L; Pereira, I A C; McInerney, M J; Austin, R N; Groves, J T; Kukor, J J; Suflita, J M; Young, L Y; Zylstra, G J; Wawrik, B

    2012-01-01

    Desulfatibacillum alkenivorans AK-01 serves as a model organism for anaerobic alkane biodegradation because of its distinctive biochemistry and metabolic versatility. The D. alkenivorans genome provides a blueprint for understanding the genetic systems involved in alkane metabolism including substrate activation, CoA ligation, carbon-skeleton rearrangement and decarboxylation. Genomic analysis suggested a route to regenerate the fumarate needed for alkane activation via methylmalonyl-CoA and predicted the capability for syntrophic alkane metabolism, which was experimentally verified. Pathways involved in the oxidation of alkanes, alcohols, organic acids and n-saturated fatty acids coupled to sulfate reduction and the ability to grow chemolithoautotrophically were predicted. A complement of genes for motility and oxygen detoxification suggests that D. alkenivorans may be physiologically adapted to a wide range of environmental conditions. The D. alkenivorans genome serves as a platform for further study of anaerobic, hydrocarbon-oxidizing microorganisms and their roles in bioremediation, energy recovery and global carbon cycling.

  8. Assessment of AK (Above Knee) Prosthesis with Different Ankle Assembly Using GRF Pattern in Stance Phase

    NASA Astrophysics Data System (ADS)

    Kim, Sung-Min; Kim, Sung-Jae; Bae, Ha-Suk

    In this study, ground reaction force (GRF), absolute symmetry index (ASI) and coefficient of variation (CV) of fixed, single-axis and multi-axis prosthetic ankle assemblies were investigated by biomechanical evaluation of above knee amputees. In the experiments, 37 normal male volunteers, two male and two female Above Knee (AK) amputees GRF data were tested with fixed, single-axis and multi-axis prosthetic ankle assembly. A gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance phase for ten points. The results showed that fixed-axis ankle assembly was superior to other two ankle assemblies for forwarding and braking forces. Multi-axis ankle was relatively superior to other two ankle assemblies for gait balancing and movement of the mass center. Single-axis ankle was relatively superior to the other two ankle assemblies for CV and ASI of GRF.

  9. Decadal trends in aerosol chemical composition at Barrow, AK: 1976-2008

    NASA Astrophysics Data System (ADS)

    Quinn, P. K.; Bates, T. S.; Schulz, K.; Shaw, G. E.

    2009-09-01

    Aerosol measurements at Barrow, AK during the past 30 years have identified the long range transport of pollution associated with Arctic Haze as well as ocean-derived aerosols of more local origin. Here, we focus on measurements of aerosol chemical composition to assess 1) trends in Arctic Haze aerosol and implications for source regions, 2) the interaction between pollution-derived and ocean-derived aerosols and the resulting impacts on the chemistry of the Arctic boundary layer, and 3) the response of aerosols to a changing climate. Aerosol chemical composition measured at Barrow, AK during the Arctic haze season is compared for the years 1976-1977 and 1997-2008. Based on these two data sets, concentrations of non-sea salt (nss) sulfate (SO4=) and non-crustal (nc) vanadium (V) have decreased by about 60% over this 30 year period. Consistency in the ratios of nss SO4=/ncV and nc manganese (Mn)/ncV between the two data sets indicates that, although emissions have decreased in the source regions, the source regions have remained the same over this time period. The measurements from 1997-2008 indicate that, during the haze season, the nss SO4= aerosol at Barrow is becoming less neutralized by ammonium (NH4+) yielding an increasing sea salt aerosol chloride (Cl-) deficit. The expected consequence is an increase in the release of Cl atoms to the atmosphere and a change in the lifetime of volatile organic compounds (VOCs) including methane. In addition, summertime concentrations of biogenically-derived methanesulfonate (MSA-) and nss SO4= are increasing at a rate of 12 and 8% per year, respectively. Further research is required to assess the environmental factors behind the increasing concentrations of biogenic aerosol.

  10. Computer Stimulation

    ERIC Educational Resources Information Center

    Moore, John W.; Moore, Elizabeth

    1977-01-01

    Discusses computer simulation approach of Limits to Growth, in which interactions of five variables (population, pollution, resources, food per capita, and industrial output per capita) indicate status of the world. Reviews other books that predict future of the world. (CS)

  11. Computer Poker

    ERIC Educational Resources Information Center

    Findler, Nicholas V.

    1978-01-01

    This familiar card game has interested mathematicians, economists, and psychologists as a model of decision-making in the real world. It is now serving as a vehicle for investigations in computer science. (Author/MA)

  12. Evolutionary Computing

    SciTech Connect

    Patton, Robert M; Cui, Xiaohui; Jiao, Yu; Potok, Thomas E

    2008-01-01

    The rate at which information overwhelms humans is significantly more than the rate at which humans have learned to process, analyze, and leverage this information. To overcome this challenge, new methods of computing must be formulated, and scientist and engineers have looked to nature for inspiration in developing these new methods. Consequently, evolutionary computing has emerged as new paradigm for computing, and has rapidly demonstrated its ability to solve real-world problems where traditional techniques have failed. This field of work has now become quite broad and encompasses areas ranging from artificial life to neural networks. This chapter focuses specifically on two sub-areas of nature-inspired computing: Evolutionary Algorithms and Swarm Intelligence.

  13. Computer Calculus.

    ERIC Educational Resources Information Center

    Steen, Lynn Arthur

    1981-01-01

    The development of symbolic computer algebra designed to manipulate abstract mathematical expressions is discussed. The ability of this software to mimic the standard patterns of human problem solving represents a major advance toward "true" artificial intelligence. (MP)

  14. Personal Computers.

    ERIC Educational Resources Information Center

    Toong, Hoo-min D.; Gupta, Amar

    1982-01-01

    Describes the hardware, software, applications, and current proliferation of personal computers (microcomputers). Includes discussions of microprocessors, memory, output (including printers), application programs, the microcomputer industry, and major microcomputer manufacturers (Apple, Radio Shack, Commodore, and IBM). (JN)

  15. LHC Computing

    SciTech Connect

    Lincoln, Don

    2015-07-28

    The LHC is the world’s highest energy particle accelerator and scientists use it to record an unprecedented amount of data. This data is recorded in electronic format and it requires an enormous computational infrastructure to convert the raw data into conclusions about the fundamental rules that govern matter. In this video, Fermilab’s Dr. Don Lincoln gives us a sense of just how much data is involved and the incredible computer resources that makes it all possible.

  16. Quantum Computing

    DTIC Science & Technology

    1998-04-01

    information representation and processing technology, although faster than the wheels and gears of the Charles Babbage computation machine, is still in...the same computational complexity class as the Babbage machine, with bits of information represented by entities which obey classical (non-quantum...nuclear double resonances Charles M Bowden and Jonathan P. Dowling Weapons Sciences Directorate, AMSMI-RD-WS-ST Missile Research, Development, and

  17. Computational chemistry

    NASA Technical Reports Server (NTRS)

    Arnold, J. O.

    1987-01-01

    With the advent of supercomputers, modern computational chemistry algorithms and codes, a powerful tool was created to help fill NASA's continuing need for information on the properties of matter in hostile or unusual environments. Computational resources provided under the National Aerodynamics Simulator (NAS) program were a cornerstone for recent advancements in this field. Properties of gases, materials, and their interactions can be determined from solutions of the governing equations. In the case of gases, for example, radiative transition probabilites per particle, bond-dissociation energies, and rates of simple chemical reactions can be determined computationally as reliably as from experiment. The data are proving to be quite valuable in providing inputs to real-gas flow simulation codes used to compute aerothermodynamic loads on NASA's aeroassist orbital transfer vehicles and a host of problems related to the National Aerospace Plane Program. Although more approximate, similar solutions can be obtained for ensembles of atoms simulating small particles of materials with and without the presence of gases. Computational chemistry has application in studying catalysis, properties of polymers, all of interest to various NASA missions, including those previously mentioned. In addition to discussing these applications of computational chemistry within NASA, the governing equations and the need for supercomputers for their solution is outlined.

  18. A Fortunate Story of an Unusual AK-47 Bullet Trajectory: Always Keep a Smartphone in Your Pocket.

    PubMed

    Thabouillot, Oscar; Perrier, Pierre; Roche, Nicolas-Charles; Agard, David; Barbier, Olivier; Martin, Guillaume; Viant, Eric; Leclere, Jean-Baptiste

    2016-06-01

    This is a report of a fortunate story of an unusual AK-47 bullet trajectory which took place during the Paris (France) attack of November 13th, 2015. A young man, trying to protect his girlfriend, interfered between her and a shooter. He had been wounded in the posterior compartment of the thigh. The bullet penetrated him and, instead of exiting, rebound against his Smartphone, which was in the front pocket of his pants. Thanks to that, the missile bullet did not injure his girlfriend but ended its trajectory in the fat tissue of his thigh. Thabouillot O , Perrier P , Roche NC , Agard D , Barbier O , Martin G , Viant E , Leclere JB . A fortunate story of an unusual AK-47 bullet trajectory: always keep a Smartphone in your pocket. Prehosp Disaster Med, 2016;31(3):343-345.

  19. Integrative computed tomographic imaging of cardiac structure, function, perfusion, and viability.

    PubMed

    Thilo, Christian; Hanley, Michael; Bastarrika, Gorka; Ruzsics, Balazs; Schoepf, U Joseph

    2010-01-01

    Recent advances in multidetector-row computed tomography (MDCT) technology have created new opportunities in cardiac imaging and provided new insights into a variety of disease states. Use of 64-slice coronary computed tomography angiography has been validated for the evaluation of clinically relevant coronary artery stenosis with high negative predictive values for ruling out significant obstructive disease. This technology has also advanced the care of patients with acute chest pain by simultaneous assessment of acute coronary syndrome, pulmonary embolism, and acute aortic syndrome ("triple rule out"). Although MDCT has been instrumental in the advancement of cardiac imaging, there are still limitations in patients with high or irregular heart rates. Newer MDCT scanner generations hold promise to improve some of these limitations for noninvasive cardiac imaging. The evaluation of coronary artery stenosis remains the primary clinical indication for cardiac computed tomography angiography. However, the use of MDCT for simultaneous assessment of coronary artery stenosis, atherosclerotic plaque formation, ventricular function, myocardial perfusion, and viability with a single modality is under intense investigation. Recent technical developments hold promise for accomplishing this goal and establishing MDCT as a comprehensive stand-alone test for integrative imaging of coronary heart disease.

  20. Comparison of image features calculated in different dimensions for computer-aided diagnosis of lung nodules

    NASA Astrophysics Data System (ADS)

    Xu, Ye; Lee, Michael C.; Boroczky, Lilla; Cann, Aaron D.; Borczuk, Alain C.; Kawut, Steven M.; Powell, Charles A.

    2009-02-01

    Features calculated from different dimensions of images capture quantitative information of the lung nodules through one or multiple image slices. Previously published computer-aided diagnosis (CADx) systems have used either twodimensional (2D) or three-dimensional (3D) features, though there has been little systematic analysis of the relevance of the different dimensions and of the impact of combining different dimensions. The aim of this study is to determine the importance of combining features calculated in different dimensions. We have performed CADx experiments on 125 pulmonary nodules imaged using multi-detector row CT (MDCT). The CADx system computed 192 2D, 2.5D, and 3D image features of the lesions. Leave-one-out experiments were performed using five different combinations of features from different dimensions: 2D, 3D, 2.5D, 2D+3D, and 2D+3D+2.5D. The experiments were performed ten times for each group. Accuracy, sensitivity and specificity were used to evaluate the performance. Wilcoxon signed-rank tests were applied to compare the classification results from these five different combinations of features. Our results showed that 3D image features generate the best result compared with other combinations of features. This suggests one approach to potentially reducing the dimensionality of the CADx data space and the computational complexity of the system while maintaining diagnostic accuracy.

  1. Performance of the high-resolution atmospheric model HRRR-AK for correcting geodetic observations from spaceborne radars.

    PubMed

    Gong, W; Meyer, F J; Webley, P; Morton, D

    2013-10-27

    [1] Atmospheric phase delays are considered to be one of the main performance limitations for high-quality satellite radar techniques, especially when applied to ground deformation monitoring. Numerical weather prediction (NWP) models are widely seen as a promising tool for the mitigation of atmospheric delays as they can provide knowledge of the atmospheric conditions at the time of Synthetic Aperture Radar data acquisition. However, a thorough statistical analysis of the performance of using NWP production in radar signal correction is missing to date. This study provides a quantitative analysis of the accuracy in using operational NWP products for signal delay correction in satellite radar geodetic remote sensing. The study focuses on the temperate, subarctic, and Arctic climate regions due to a prevalence of relevant geophysical signals in these areas. In this study, the operational High Resolution Rapid Refresh over the Alaska region (HRRR-AK) model is used and evaluated. Five test sites were selected over Alaska (AK), USA, covering a wide range of climatic regimes that are commonly encountered in high-latitude regions. The performance of the HRRR-AK NWP model for correcting absolute atmospheric range delays of radar signals is assessed by comparing to radiosonde observations. The average estimation accuracy for the one-way zenith total atmospheric delay from 24 h simulations was calculated to be better than ∼14 mm. This suggests that the HRRR-AK operational products are a good data source for spaceborne geodetic radar observations atmospheric delay correction, if the geophysical signal to be observed is larger than 20 mm.

  2. Performance of the high-resolution atmospheric model HRRR-AK for correcting geodetic observations from spaceborne radars

    PubMed Central

    Gong, W; Meyer, F J; Webley, P; Morton, D

    2013-01-01

    [1] Atmospheric phase delays are considered to be one of the main performance limitations for high-quality satellite radar techniques, especially when applied to ground deformation monitoring. Numerical weather prediction (NWP) models are widely seen as a promising tool for the mitigation of atmospheric delays as they can provide knowledge of the atmospheric conditions at the time of Synthetic Aperture Radar data acquisition. However, a thorough statistical analysis of the performance of using NWP production in radar signal correction is missing to date. This study provides a quantitative analysis of the accuracy in using operational NWP products for signal delay correction in satellite radar geodetic remote sensing. The study focuses on the temperate, subarctic, and Arctic climate regions due to a prevalence of relevant geophysical signals in these areas. In this study, the operational High Resolution Rapid Refresh over the Alaska region (HRRR-AK) model is used and evaluated. Five test sites were selected over Alaska (AK), USA, covering a wide range of climatic regimes that are commonly encountered in high-latitude regions. The performance of the HRRR-AK NWP model for correcting absolute atmospheric range delays of radar signals is assessed by comparing to radiosonde observations. The average estimation accuracy for the one-way zenith total atmospheric delay from 24 h simulations was calculated to be better than ∼14 mm. This suggests that the HRRR-AK operational products are a good data source for spaceborne geodetic radar observations atmospheric delay correction, if the geophysical signal to be observed is larger than 20 mm. PMID:25973360

  3. Purification and characterization of Ak.1 protease, a thermostable subtilisin with a disulphide bond in the substrate-binding cleft.

    PubMed

    Toogood, H S; Smith, C A; Baker, E N; Daniel, R M

    2000-08-15

    Ak.1 protease, a thermostable subtilisin isolated originally from Bacillus st. Ak.1, was purified to homogeneity from the Escherichia coli clone PB5517. It is active against substrates containing neutral or hydrophobic branched-chain amino acids at the P(1) site, such as valine, alanine or phenylalanine. The K(m) and k(cat) of the enzyme decrease with decreasing temperature, though not to the same degree with all substrates, suggesting that specificity changes with temperature. The protease is markedly stabilized by Ca(2+) ions. At 70 degrees C, a 10-fold increase in Ca(2+) concentration increases the half-life by three orders of magnitude. Ak.1 protease is stabilized by Ca(2+) to a greater extent than is thermitase. This may be due, in part, to the presence of an extra Ca(2+)-binding site in Ak.1 protease. Other metal ions, such as Sr(2+), increase the thermostability of the enzyme, but to a significantly lower degree than does Ca(2+). The structure of the protease showed the presence of a disulphide bond located within the active-site cleft. This bond influences both enzyme activity and thermostability. The disulphide bond appears to have a dual role: maintaining the integrity of the substrate-binding cleft and increasing the thermostability of the protease. The protease was originally investigated to determine its usefulness in the clean-up of DNA at high temperatures. However, it was found that this protease has a limited substrate specificity, so this application was not explored further.

  4. Effect of Crystal Structure Fineness for Charge Alloy AK6M2 on Its Flux Treatment Efficiency

    NASA Astrophysics Data System (ADS)

    Nikitin, K. V.; Nikitin, V. I.; Timoshkin, I. Yu.; Chikova, O. A.

    2016-09-01

    The effect of charge billet structure and form of fluxes on structure, density, and gas content of alloy AK6M2 (Al - Si - Cu system) is studied. Alloys prepared from finely crystalline charge billet have smaller phase component sizes, lower gas content, and increased solid state density, and use of coarsely crystalline charge billets for alloy preparation necessitates an increase in flux preparation consumption in the stage of alloy preparation for casting.

  5. [Insignificant carcinogenicity of chrysotile asbestos of the Ak-Dovurak deposits in Russia and its possible links].

    PubMed

    Pylev, L N; Vasil'eva, L A; Krinari, G A

    2004-01-01

    Thrice intrapleural injection of 20 mg of dust of the chrysotile from the Ak-Dovurak deposit caused pleural mesothelioma in 10.7% of the rats, which was significantly less than that upon exposure to the chrysotiles from other deposits and amphiboles. The reason for the less carcinogenicity of this chrysotile is the structural features of the surface of its fibrils, namely, its high homogeneity and hence the lack of sites at which the electrically charged centers may be located.

  6. Computational mechanics

    SciTech Connect

    Goudreau, G.L.

    1993-03-01

    The Computational Mechanics thrust area sponsors research into the underlying solid, structural and fluid mechanics and heat transfer necessary for the development of state-of-the-art general purpose computational software. The scale of computational capability spans office workstations, departmental computer servers, and Cray-class supercomputers. The DYNA, NIKE, and TOPAZ codes have achieved world fame through our broad collaborators program, in addition to their strong support of on-going Lawrence Livermore National Laboratory (LLNL) programs. Several technology transfer initiatives have been based on these established codes, teaming LLNL analysts and researchers with counterparts in industry, extending code capability to specific industrial interests of casting, metalforming, and automobile crash dynamics. The next-generation solid/structural mechanics code, ParaDyn, is targeted toward massively parallel computers, which will extend performance from gigaflop to teraflop power. Our work for FY-92 is described in the following eight articles: (1) Solution Strategies: New Approaches for Strongly Nonlinear Quasistatic Problems Using DYNA3D; (2) Enhanced Enforcement of Mechanical Contact: The Method of Augmented Lagrangians; (3) ParaDyn: New Generation Solid/Structural Mechanics Codes for Massively Parallel Processors; (4) Composite Damage Modeling; (5) HYDRA: A Parallel/Vector Flow Solver for Three-Dimensional, Transient, Incompressible Viscous How; (6) Development and Testing of the TRIM3D Radiation Heat Transfer Code; (7) A Methodology for Calculating the Seismic Response of Critical Structures; and (8) Reinforced Concrete Damage Modeling.

  7. A founder EIF2AK4 mutation causes an aggressive form of pulmonary arterial hypertension in Iberian Gypsies.

    PubMed

    Tenorio, J; Navas, P; Barrios, E; Fernández, L; Nevado, J; Quezada, C A; López-Meseguer, M; Arias, P; Mena, R; Lobo, J L; Alvarez, C; Heath, K; Escribano-Subías, P; Lapunzina, P

    2015-12-01

    Pulmonary arterial hypertension (PAH) is a pathological condition characterized by a persistent and progressive elevation of pulmonary vascular resistance with devastating consequences if untreated. In the past recent years, several genes have been related to PAH, however, the molecular defect remains unknown in a significant proportion of patients with familial PAH (∼20%). During the past few years, we have observed that PAH shows a particular behavior in Iberian Gypsies, with more aggressive course and frequently affecting multiple members of the same family. We studied five Gypsy families in whom at least one individual from each family developed a severe form of PAH and in whom no mutation had been identified in the common genes. We applied SNP-array-based homozygosity mapping in three families and obtained, among others, one of which included the gene EIF2AK4, recently reported in patients with PAH from group-1' pulmonary veno-occlusive disease (PVOD) and pulmonary capillary hemangiomatosis (PCH). Subsequently, we sequenced EIF2AK4 and found a homozygous mutation in all five families: c.3344C>T(p.P1115L). The majority of our patients required early lung transplantation. Hence, this mutation appeared with a more severe phenotype than previously reported for other EIF2AK4 mutations. The finding of this novel mutation is important for genetic counseling and calculation of population recurrence risks.

  8. s-triazine degrading bacterial isolate Arthrobacter sp. AK-YN10, a candidate for bioaugmentation of atrazine contaminated soil.

    PubMed

    Sagarkar, Sneha; Bhardwaj, Pooja; Storck, Veronika; Devers-Lamrani, Marion; Martin-Laurent, Fabrice; Kapley, Atya

    2016-01-01

    The Arthrobacter sp. strain AK-YN10 is an s-triazine pesticide degrading bacterium isolated from a sugarcane field in Central India with history of repeated atrazine use. AK-YN10 was shown to degrade 99 % of atrazine in 30 h from media supplemented with 1000 mg L(-1) of the herbicide. Draft genome sequencing revealed similarity to pAO1, TC1, and TC2 catabolic plasmids of the Arthrobacter taxon. Plasmid profiling analyses revealed the presence of four catabolic plasmids. The trzN, atzB, and atzC atrazine-degrading genes were located on a plasmid of approximately 113 kb.The flagellar operon found in the AK-YN10 draft genome suggests motility, an interesting trait for a bioremediation agent, and was homologous to that of Arthrobacter chlorophenolicus. The multiple s-triazines degradation property of this isolate makes it a good candidate for bioremediation of soils contaminated by s-triazine pesticides.

  9. Biosorption of Pb(II) by Bacillus badius AK strain originating from rotary drum compost of water hyacinth.

    PubMed

    Vishan, Isha; Laha, Avishek; Kalamdhad, Ajay

    2017-03-01

    The presence of heavy metals in the environment due to industrial activities is of serious concern because of their toxic behaviour towards humans and other forms of life. Biosorption of Pb(II) using dry bacterial biomass of Bacillus badius AK, previously isolated from water hyacinth compost, has been undertaken in batch system. The optimum conditions of biosorption were determined by investigating the initial pH, contact time, initial biomass dosage at constant temperature of 40 °C, initial metal concentration of 100 mg/L and rotational speed of 150 rpm. The optimum pH was found to be 5 and equilibrium contact time was 2.5 h. The maximum biosorption capacity of Pb(II) on Bacillus badius AK was 138.8 mg/g at an initial concentration of 100 mg/L. A kinetics study revealed that the adsorption process followed pseudo second order rate kinetics. The experimental data were fitted to the Langmuir isotherm. Characterization of the biomass indicated the presence of several functional groups. The results indicated that the bacterium Bacillus badius AK is efficient for the removal of Pb(II).

  10. A laminaribiose-hydrolyzing enzyme, AkLab, from the common sea hare Aplysia kurodai and its transglycosylation activity.

    PubMed

    Kumagai, Yuya; Satoh, Takuya; Inoue, Akira; Ojima, Takao

    2014-01-01

    Endo-β-1,3-glucanases (laminarinase, EC 3.2.1.6) from marine molluscs specifically degrades laminarin from brown algae producing laminaribiose and glucose, but hardly degrades laminaribiose. For the complete depolymerization of laminarin, other enzymes that can hydrolyze laminaribiose appear to be necessary. In the present study, we successfully isolated a laminaribiose-hydrolyzing enzyme from the digestive fluid of a marine gastropod Aplysia kurodai by ammonium sulfate fractionation followed by conventional column chromatographies. This enzyme, AkLab, named after the scientific name of this animal and substrate specificity toward laminaribiose, shows an approximate molecular mass of 110kDa on SDS-PAGE, and optimum pH and temperature at around pH5.5 and 50°C, respectively. AkLab rapidly hydrolyzes laminaribiose and p-nitrophenyl-β-D-glucoside, and slowly cellobiose, gentiobiose and lactose, but not sucrose and maltose. AkLab shows high transglycosylation activity and can produce a series of laminarioligosaccharides larger than laminaritetraose from laminaribiose (a donor substrate) and laminaritriose (an acceptor substrate). This enzyme is suggested to be a member of glycosyl hydrolase family 1 by the analysis of partial amino-acid sequences.

  11. Quantum computers.

    PubMed

    Ladd, T D; Jelezko, F; Laflamme, R; Nakamura, Y; Monroe, C; O'Brien, J L

    2010-03-04

    Over the past several decades, quantum information science has emerged to seek answers to the question: can we gain some advantage by storing, transmitting and processing information encoded in systems that exhibit unique quantum properties? Today it is understood that the answer is yes, and many research groups around the world are working towards the highly ambitious technological goal of building a quantum computer, which would dramatically improve computational power for particular tasks. A number of physical systems, spanning much of modern physics, are being developed for quantum computation. However, it remains unclear which technology, if any, will ultimately prove successful. Here we describe the latest developments for each of the leading approaches and explain the major challenges for the future.

  12. Qubus computation

    NASA Astrophysics Data System (ADS)

    Munro, W. J.; Nemoto, Kae; Spiller, T. P.; van Loock, P.; Braunstein, Samuel L.; Milburn, G. J.

    2006-08-01

    Processing information quantum mechanically is known to enable new communication and computational scenarios that cannot be accessed with conventional information technology (IT). We present here a new approach to scalable quantum computing---a "qubus computer"---which realizes qubit measurement and quantum gates through interacting qubits with a quantum communication bus mode. The qubits could be "static" matter qubits or "flying" optical qubits, but the scheme we focus on here is particularly suited to matter qubits. Universal two-qubit quantum gates may be effected by schemes which involve measurement of the bus mode, or by schemes where the bus disentangles automatically and no measurement is needed. This approach enables a parity gate between qubits, mediated by a bus, enabling near-deterministic Bell state measurement and entangling gates. Our approach is therefore the basis for very efficient, scalable QIP, and provides a natural method for distributing such processing, combining it with quantum communication.

  13. Computational Psychiatry

    PubMed Central

    Wang, Xiao-Jing; Krystal, John H.

    2014-01-01

    Psychiatric disorders such as autism and schizophrenia arise from abnormalities in brain systems that underlie cognitive, emotional and social functions. The brain is enormously complex and its abundant feedback loops on multiple scales preclude intuitive explication of circuit functions. In close interplay with experiments, theory and computational modeling are essential for understanding how, precisely, neural circuits generate flexible behaviors and their impairments give rise to psychiatric symptoms. This Perspective highlights recent progress in applying computational neuroscience to the study of mental disorders. We outline basic approaches, including identification of core deficits that cut across disease categories, biologically-realistic modeling bridging cellular and synaptic mechanisms with behavior, model-aided diagnosis. The need for new research strategies in psychiatry is urgent. Computational psychiatry potentially provides powerful tools for elucidating pathophysiology that may inform both diagnosis and treatment. To achieve this promise will require investment in cross-disciplinary training and research in this nascent field. PMID:25442941

  14. Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours.

    PubMed

    Amthauer, H; Denecke, T; Rohlfing, T; Ruf, J; Böhmig, M; Gutberlet, M; Plöckinger, U; Felix, R; Lemke, A J

    2005-07-01

    The objective was the evaluation of single photon emission computed tomography (SPECT) with integrated low dose computed tomography (CT) in comparison with a retrospective fusion of SPECT and high-resolution CT and a side-by-side analysis for lesion localisation in patients with neuroendocrine tumours. Twenty-seven patients were examined by multidetector CT. Additionally, as part of somatostatin receptor scintigraphy (SRS), an integrated SPECT-CT was performed. SPECT and CT data were fused using software with a registration algorithm based on normalised mutual information. The reliability of the topographic assignment of lesions in SPECT-CT, retrospective fusion and side-by-side analysis was evaluated by two blinded readers. Two patients were not enrolled in the final analysis because of misregistrations in the retrospective fusion. Eighty-seven foci were included in the analysis. For the anatomical assignment of foci, SPECT-CT and retrospective fusion revealed overall accuracies of 91 and 94% (side-by-side analysis 86%). The correct identification of foci as lymph node manifestations (n=25) was more accurate by retrospective fusion (88%) than from SPECT-CT images (76%) or by side-by-side analysis (60%). Both modalities of image fusion appear to be well suited for the localisation of SRS foci and are superior to side-by-side analysis of non-fused images especially concerning lymph node manifestations.

  15. Anchorage, AK

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Anchorage, Alaska and Cook Inlet are seen in this 30 by 30 km (19 by 19 miles) sub-image, acquired May 12, 2000 by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER). Orbiting at an altitude of 705 km (430 miles) on board NASA's Terra satellite, ASTER provides data at a resolution of 15 m (47 feet) and allows creation of this simulated natural color image. At the center of the image is the Ted Stevens Anchorage International Airport; in the upper right corner is Elmendorf Air Force Base. Dark green coniferous forests are seen in the northwest part of the image. A golf course, with its lush green fairways, is just south of the Air Force Base.

    The image covers an area of 30 by 30 km, was acquired May 12, 2000, and is located at 61.2 degrees north latitude and 149.9 degrees west longitude.

    Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) is one of five Earth-observing instruments launched December 18, 1999, on NASA's Terra satellite. The instrument was built by Japan's Ministry of International Trade and Industry. A joint U.S./Japan science team is responsible for validation and calibration of the instrument and the data products. Dr. Anne Kahle at NASA's Jet Propulsion Laboratory, Pasadena, California, is the U.S. science team leader; Moshe Pniel of JPL is the project manager. ASTER is the only high-resolution imaging sensor on Terra. The primary goal of the ASTER mission is to obtain high-resolution image data in 14 channels over the entire land surface, as well as black and white stereo images. With revisit time of between 4 and 16 days, ASTER will provide the capability for repeat coverage of changing areas on Earth's surface.

    The broad spectral coverage and high spectral resolution of ASTER will provide scientists in numerous disciplines with critical information for surface mapping and monitoring dynamic conditions and temporal change. Examples of applications include monitoring glacial advances and retreats, potentially active volcanoes, thermal pollution, and coral reef degradation; identifying crop stress; determining cloud morphology and physical properties; evaluating wetlands; mapping surface temperature of soils and geology; and measuring surface heat balance.

  16. Computational mechanics

    SciTech Connect

    Raboin, P J

    1998-01-01

    The Computational Mechanics thrust area is a vital and growing facet of the Mechanical Engineering Department at Lawrence Livermore National Laboratory (LLNL). This work supports the development of computational analysis tools in the areas of structural mechanics and heat transfer. Over 75 analysts depend on thrust area-supported software running on a variety of computing platforms to meet the demands of LLNL programs. Interactions with the Department of Defense (DOD) High Performance Computing and Modernization Program and the Defense Special Weapons Agency are of special importance as they support our ParaDyn project in its development of new parallel capabilities for DYNA3D. Working with DOD customers has been invaluable to driving this technology in directions mutually beneficial to the Department of Energy. Other projects associated with the Computational Mechanics thrust area include work with the Partnership for a New Generation Vehicle (PNGV) for ''Springback Predictability'' and with the Federal Aviation Administration (FAA) for the ''Development of Methodologies for Evaluating Containment and Mitigation of Uncontained Engine Debris.'' In this report for FY-97, there are five articles detailing three code development activities and two projects that synthesized new code capabilities with new analytic research in damage/failure and biomechanics. The article this year are: (1) Energy- and Momentum-Conserving Rigid-Body Contact for NIKE3D and DYNA3D; (2) Computational Modeling of Prosthetics: A New Approach to Implant Design; (3) Characterization of Laser-Induced Mechanical Failure Damage of Optical Components; (4) Parallel Algorithm Research for Solid Mechanics Applications Using Finite Element Analysis; and (5) An Accurate One-Step Elasto-Plasticity Algorithm for Shell Elements in DYNA3D.

  17. Computer viruses

    NASA Technical Reports Server (NTRS)

    Denning, Peter J.

    1988-01-01

    The worm, Trojan horse, bacterium, and virus are destructive programs that attack information stored in a computer's memory. Virus programs, which propagate by incorporating copies of themselves into other programs, are a growing menace in the late-1980s world of unprotected, networked workstations and personal computers. Limited immunity is offered by memory protection hardware, digitally authenticated object programs,and antibody programs that kill specific viruses. Additional immunity can be gained from the practice of digital hygiene, primarily the refusal to use software from untrusted sources. Full immunity requires attention in a social dimension, the accountability of programmers.

  18. LHC Computing

    ScienceCinema

    Lincoln, Don

    2016-07-12

    The LHC is the world’s highest energy particle accelerator and scientists use it to record an unprecedented amount of data. This data is recorded in electronic format and it requires an enormous computational infrastructure to convert the raw data into conclusions about the fundamental rules that govern matter. In this video, Fermilab’s Dr. Don Lincoln gives us a sense of just how much data is involved and the incredible computer resources that makes it all possible.

  19. Computer systems

    NASA Technical Reports Server (NTRS)

    Olsen, Lola

    1992-01-01

    In addition to the discussions, Ocean Climate Data Workshop hosts gave participants an opportunity to hear about, see, and test for themselves some of the latest computer tools now available for those studying climate change and the oceans. Six speakers described computer systems and their functions. The introductory talks were followed by demonstrations to small groups of participants and some opportunities for participants to get hands-on experience. After this familiarization period, attendees were invited to return during the course of the Workshop and have one-on-one discussions and further hands-on experience with these systems. Brief summaries or abstracts of introductory presentations are addressed.

  20. Anomalous right coronary artery arising next to the left coronary ostium: unambiguous detection of the anatomy by computed tomography and evaluation of functional significance by cardiovascular magnetic resonance.

    PubMed

    Korosoglou, Grigorios; Heye, Tobias; Giannitsis, Evangelos; Hosch, Waldemar; Kauczor, Hans U; Katus, Hugo A

    2010-11-19

    Herein we report on the diagnostic potential of multi-detector row computed tomography (MDCT) combined with cardiovascular magnetic resonance (CMR) for the diagnostic workup in an adult patient with a rare coronary anomaly. MDCT unambiguously detected the anomalous right coronary artery (RCA), which originated next to the left coronary ostium and coursed inter-arterially between the ascending aorta and the pulmonary trunk. The intramural proximal intussusception of the ectopic RCA could be clearly appreciated on MDCT images, while multiple mixed plaques were detected in the left anterior descending (LAD), resulting in moderate stenosis of this vessel. CMR during adenosine infusion ruled-out inducible ischemia, yielding normal perfusion patterns both in the RCA and in the LAD coronary territory. Since ischemia was not demonstrated by stress CMR, revascularization was not performed.

  1. Computational Hearing

    DTIC Science & Technology

    1998-11-01

    ranging from the anatomy and physiology of the auditory pathway to the perception of speech and music under both ideal and not-so-ideal (but more...physiology of various parts of the auditory pathway, to auditory prostheses, speech and audio coding, computational models of pitch and timbre , the role of

  2. Library Computing.

    ERIC Educational Resources Information Center

    Dayall, Susan A.; And Others

    1987-01-01

    Six articles on computers in libraries discuss training librarians and staff to use new software; appropriate technology; system upgrades of the Research Libraries Group's information system; pre-IBM PC microcomputers; multiuser systems for small to medium-sized libraries; and a library user's view of the traditional card catalog. (EM)

  3. Computational trigonometry

    SciTech Connect

    Gustafson, K.

    1994-12-31

    By means of the author`s earlier theory of antieigenvalues and antieigenvectors, a new computational approach to iterative methods is presented. This enables an explicit trigonometric understanding of iterative convergence and provides new insights into the sharpness of error bounds. Direct applications to Gradient descent, Conjugate gradient, GCR(k), Orthomin, CGN, GMRES, CGS, and other matrix iterative schemes will be given.

  4. Computational Estimation

    ERIC Educational Resources Information Center

    Fung, Maria G.; Latulippe, Christine L.

    2010-01-01

    Elementary school teachers are responsible for constructing the foundation of number sense in youngsters, and so it is recommended that teacher-training programs include an emphasis on number sense to ensure the development of dynamic, productive computation and estimation skills in students. To better prepare preservice elementary school teachers…

  5. Business Computers.

    ERIC Educational Resources Information Center

    Canipe, Stephen L.

    A brief definition of some fundamentals of microcomputers and of the ways they may be used in small businesses can help potential buyers make informed purchases. Hardware (the mechanical devices from which computers are made) described here are the video display, keyboard, central processing unit, "random access" and "read only" memories, cassette…

  6. Computer Guerrillas.

    ERIC Educational Resources Information Center

    Immel, A. Richard

    1983-01-01

    Describes several cases in which microcomputers were used to prevent large organizations (e.g., utility companies, U.S. Government Forestry Commission) from carrying out actions considered not to be in the public's best interests. The use of the computers by social activitists in their efforts to halt environmental destruction is discussed. (EAO)

  7. Computer Corner.

    ERIC Educational Resources Information Center

    Mason, Margie

    1985-01-01

    This article: describes how to prevent pins on game paddles from breaking; suggests using needlepoint books for ideas to design computer graphics; lists a BASIC program to create a Christmas tree, with extension activities; suggests a LOGO Christmas activity; and describes a book on the development of microcomputers. (JN)

  8. Computational Physics.

    ERIC Educational Resources Information Center

    Borcherds, P. H.

    1986-01-01

    Describes an optional course in "computational physics" offered at the University of Birmingham. Includes an introduction to numerical methods and presents exercises involving fast-Fourier transforms, non-linear least-squares, Monte Carlo methods, and the three-body problem. Recommends adding laboratory work into the course in the…

  9. Computational Musicology.

    ERIC Educational Resources Information Center

    Bel, Bernard; Vecchione, Bernard

    1993-01-01

    Asserts that a revolution has been occurring in musicology since the 1970s. Contends that music has change from being only a source of emotion to appearing more open to science and techniques based on computer technology. Describes recent research and other writings about the topic and provides an extensive bibliography. (CFR)

  10. Computer Corner.

    ERIC Educational Resources Information Center

    Smith, David A.; And Others

    1986-01-01

    APL was invented specifically as a mathematical teaching tool, and is an excellent vehicle for teaching mathematical concepts using computers. This article illustrates the use of APL in teaching many different topics in mathematics, including logic, set theory, functions, statistics, linear algebra, and matrices. (MNS)

  11. Networking computers.

    PubMed

    McBride, D C

    1997-03-01

    This decade the role of the personal computer has shifted dramatically from a desktop device designed to increase individual productivity and efficiency to an instrument of communication linking people and machines in different places with one another. A computer in one city can communicate with another that may be thousands of miles away. Networking is how this is accomplished. Just like the voice network used by the telephone, computer networks transmit data and other information via modems over these same telephone lines. A network can be created over both short and long distances. Networks can be established within a hospital or medical building or over many hospitals or buildings covering many geographic areas. Those confined to one location are called LANs, local area networks. Those that link computers in one building to those at other locations are known as WANs, or wide area networks. The ultimate wide area network is the one we've all been hearing so much about these days--the Internet, and its World Wide Web. Setting up a network is a process that requires careful planning and commitment. To avoid potential pitfalls and to make certain the network you establish meets your needs today and several years down the road, several steps need to be followed. This article reviews the initial steps involved in getting ready to network.

  12. COMPUTATIONAL SOCIOLINGUISTICS.

    ERIC Educational Resources Information Center

    SEDELOW, WALTER A., JR.

    THE USE OF THE COMPUTER MAY BE ONE OF THE WAYS IN WHICH VARIED LINGUISTIC INTERESTS (SOCIOLINGUISTICS, PSYCHOLINGUISTICS) COME TO BE RENDERED INTERRELATED AND EVEN INTELLECTUALLY COHERENT. (THE CRITERION OF COHERENCE IS SET HERE AT MONISM AS TO MODELS.) ONE OF THE AUTHOR'S MAJOR INTERESTS IS A SYSTEMATIC APPROACH TO SCIENTIFIC CREATIVITY,…

  13. Computational Mathematics

    DTIC Science & Technology

    2012-03-06

    Marsha Berger, NYU) Inclusion of the Adaptation/Adjoint module, Embedded Boundary Methods in the software package Cart3D --- Transition to NASA...ONR, DOE, AFRL, DIA Cart3D used for computing Formation Flight to reduce drag and improve energy efficiency Application to Explosively Formed

  14. H2AK119Ub1 and H3K27Me3 in molecular staging for survival prediction of patients with pancreatic ductal adenocarcinoma

    PubMed Central

    Zhan, Qian; Zhu, Yi; Chen, Hao; Deng, Xiaxing; Hou, Zhaoyuan; Shen, Baiyong; Chen, Yanling; Peng, Chenghong

    2014-01-01

    Polycomb group (PcG) proteins Ring1B and EZH2, which have been characterized as catalyzing the two epigenetic modifications H2AK119 monoubiquitination (H2AK119Ub1) and H3K27 trimethylation (H3K27Me3), are well-known epigenetic silencers implicated in embryonic development and tumorigenesis. However, the status of polycomb-associated histone modifications and their clinical implications in pancreatic cancer remain unclear. Here, we performed immunohistochemistry on tissue microarrays (TMAs) containing 80 pairs of human pancreatic cancer specimens to assess the expression levels of Ring1B, H2AK119Ub1, EZH2, and H3K27Me3 in tumors. More than 50% of the tumor cells showed a high expression of H2AK119Ub1, Ring1B, and EZH2, whereas more than 50% of the tumor cells showed a low level of H3K27Me3. Different expression patterns of H2AK119Ub1 and H3K27Me3 in tumors were negatively correlated (r = −0.247, P = 0.027). Both H2AK119Ub1 and H3K27Me3 independently predicted the clinical prognosis. In particular, a combinatorial pattern of elevated H2AK119Ub1 and decreased H3K27Me3 in tumors was significantly correlated with a poorer prognosis. Furthermore, compared to the tumor, lymph node, metastasis (TNM) staging system, histone modifications can discriminate the survival difference more accurately, especially for patients with stage I or stage II tumors. Simultaneous silencing of Ring1B and EZH2 via shRNA depleted H2AK119Ub1 and H3K27Me3 in the pancreatic cancer cells PanC1 and AsPC1, enhanced HOX gene derepression, and inhibited tumor cell growth in vitro and in tumor xenograft models. These results demonstrated that H2AK119Ub1 and H3K27Me3 cooperate in tumors and are associated with the clinical prognosis in combinatorial patterns. We have proposed that epigenetic modifications may serve as discriminatory biomarkers for molecular staging of pancreatic cancer. PMID:25431952

  15. Dynamic self-assembly in living systems as computation.

    SciTech Connect

    Bouchard, Ann Marie; Osbourn, Gordon Cecil

    2004-06-01

    Biochemical reactions taking place in living systems that map different inputs to specific outputs are intuitively recognized as performing information processing. Conventional wisdom distinguishes such proteins, whose primary function is to transfer and process information, from proteins that perform the vast majority of the construction, maintenance, and actuation tasks of the cell (assembling and disassembling macromolecular structures, producing movement, and synthesizing and degrading molecules). In this paper, we examine the computing capabilities of biological processes in the context of the formal model of computing known as the random access machine (RAM) [Dewdney AK (1993) The New Turing Omnibus. Computer Science Press, New York], which is equivalent to a Turing machine [Minsky ML (1967) Computation: Finite and Infinite Machines. Prentice-Hall, Englewood Cliffs, NJ]. When viewed from the RAM perspective, we observe that many of these dynamic self-assembly processes - synthesis, degradation, assembly, movement - do carry out computational operations. We also show that the same computing model is applicable at other hierarchical levels of biological systems (e.g., cellular or organism networks as well as molecular networks). We present stochastic simulations of idealized protein networks designed explicitly to carry out a numeric calculation. We explore the reliability of such computations and discuss error-correction strategies (algorithms) employed by living systems. Finally, we discuss some real examples of dynamic self-assembly processes that occur in living systems, and describe the RAM computer programs they implement. Thus, by viewing the processes of living systems from the RAM perspective, a far greater fraction of these processes can be understood as computing than has been previously recognized.

  16. RATIO COMPUTER

    DOEpatents

    Post, R.F.

    1958-11-11

    An electronic computer circuit is described for producing an output voltage proportional to the product or quotient of tbe voltages of a pair of input signals. ln essence, the disclosed invention provides a computer having two channels adapted to receive separate input signals and each having amplifiers with like fixed amplification factors and like negatlve feedback amplifiers. One of the channels receives a constant signal for comparison purposes, whereby a difference signal is produced to control the amplification factors of the variable feedback amplifiers. The output of the other channel is thereby proportional to the product or quotient of input signals depending upon the relation of input to fixed signals in the first mentioned channel.

  17. Computational Combustion

    SciTech Connect

    Westbrook, C K; Mizobuchi, Y; Poinsot, T J; Smith, P J; Warnatz, J

    2004-08-26

    Progress in the field of computational combustion over the past 50 years is reviewed. Particular attention is given to those classes of models that are common to most system modeling efforts, including fluid dynamics, chemical kinetics, liquid sprays, and turbulent flame models. The developments in combustion modeling are placed into the time-dependent context of the accompanying exponential growth in computer capabilities and Moore's Law. Superimposed on this steady growth, the occasional sudden advances in modeling capabilities are identified and their impacts are discussed. Integration of submodels into system models for spark ignition, diesel and homogeneous charge, compression ignition engines, surface and catalytic combustion, pulse combustion, and detonations are described. Finally, the current state of combustion modeling is illustrated by descriptions of a very large jet lifted 3D turbulent hydrogen flame with direct numerical simulation and 3D large eddy simulations of practical gas burner combustion devices.

  18. Computational Physics

    NASA Astrophysics Data System (ADS)

    Thijssen, Jos

    2013-10-01

    1. Introduction; 2. Quantum scattering with a spherically symmetric potential; 3. The variational method for the Schrödinger equation; 4. The Hartree-Fock method; 5. Density functional theory; 6. Solving the Schrödinger equation in periodic solids; 7. Classical equilibrium statistical mechanics; 8. Molecular dynamics simulations; 9. Quantum molecular dynamics; 10. The Monte Carlo method; 11. Transfer matrix and diagonalisation of spin chains; 12. Quantum Monte Carlo methods; 13. The infinite element method for partial differential equations; 14. The lattice Boltzmann method for fluid dynamics; 15. Computational methods for lattice field theories; 16. High performance computing and parallelism; Appendix A. Numerical methods; Appendix B. Random number generators; References; Index.

  19. Singularity computations

    NASA Technical Reports Server (NTRS)

    Swedlow, J. L.

    1976-01-01

    An approach is described for singularity computations based on a numerical method for elastoplastic flow to delineate radial and angular distribution of field quantities and measure the intensity of the singularity. The method is applicable to problems in solid mechanics and lends itself to certain types of heat flow and fluid motion studies. Its use is not limited to linear, elastic, small strain, or two-dimensional situations.

  20. Spatial Computation

    DTIC Science & Technology

    2003-12-01

    particular program, synthesized under compiler control from the application source code . The translation is illustrated in Figure 1.4. From now on, when we use...very efficient method of exploring the design of complex application-specific system-on-a-chip devices using only the application source code . • New...computation gates. This frees, but also complicates, the com- pilation process. In order to handle the great semantic gap between the source code and the

  1. Computational enzymology.

    PubMed

    Lonsdale, Richard; Ranaghan, Kara E; Mulholland, Adrian J

    2010-04-14

    Molecular simulations and modelling are changing the science of enzymology. Calculations can provide detailed, atomic-level insight into the fundamental mechanisms of biological catalysts. Computational enzymology is a rapidly developing area, and is testing theories of catalysis, challenging 'textbook' mechanisms, and identifying novel catalytic mechanisms. Increasingly, modelling is contributing directly to experimental studies of enzyme-catalysed reactions. Potential practical applications include interpretation of experimental data, catalyst design and drug development.

  2. Computational Electromagnetics

    DTIC Science & Technology

    2011-02-20

    a collaboration between Caltech’s postdoctoral associate N. Albin and OB) have shown that, for a variety of reasons, the first-order...KZK approximation", Nathan Albin , Oscar P. Bruno, Theresa Y. Cheung and Robin O. Cleveland, preprint, (2011) "A Spectral FC Solver for the Compressible...Navier-Stokes Equations in General Domains I: Explicit time-stepping" Nathan Albin and Oscar P. Bruno, To appear in Journal of Computational Physics

  3. A minimum data set approach to post-mortem computed tomography reporting for anthropological biological profiling.

    PubMed

    Brough, Alison L; Morgan, Bruno; Robinson, Claire; Black, Sue; Cunningham, Craig; Adams, Catherine; Rutty, Guy N

    2014-12-01

    Anthropological examination of bones is routinely undertaken in medico-legal investigations to establish an individual's biological profile, particularly their age. This often requires the removal of soft tissue from bone (de-fleshing), which, especially when dealing with the recently deceased, is a time consuming and invasive procedure. Recent advances in multi-detector computed tomography have made it practical to rapidly acquire high-resolution morphological skeletal information from images of "fleshed" remains. The aim of this study was to develop a short standard form, created from post-mortem computed tomography images, that contains the minimum image-set required to anthropologically assess an individual. The proposed standard forms were created for 31 juvenile forensic cases with known age-at-death, spanning the full age range of the developing human. Five observers independently used this form to estimate age-at-death. All observers estimated age in all cases, and all estimations were within the accepted ranges for traditional anthropological and odontological assessment. This study supports the implementation of this approach in forensic radiological practice.

  4. DETECTION OF SHARP SYMMETRIC FEATURES IN THE CIRCUMBINARY DISK AROUND AK Sco

    SciTech Connect

    Janson, Markus; Asensio-Torres, Ruben; Thalmann, Christian; Meyer, Michael R.; Garufi, Antonio; Boccaletti, Anthony; Maire, Anne-Lise; Henning, Thomas; Pohl, Adriana; Zurlo, Alice; Marzari, Francesco; Carson, Joseph C.; Augereau, Jean-Charles; Desidera, Silvano

    2016-01-01

    The Search for Planets Orbiting Two Stars survey aims to study the formation and distribution of planets in binary systems by detecting and characterizing circumbinary planets and their formation environments through direct imaging. With the SPHERE Extreme Adaptive Optics instrument, a good contrast can be achieved even at small (<300 mas) separations from bright stars, which enables studies of planets and disks in a separation range that was previously inaccessible. Here, we report the discovery of resolved scattered light emission from the circumbinary disk around the well-studied young double star AK Sco, at projected separations in the ∼13–40 AU range. The sharp morphology of the imaged feature is surprising, given the smooth appearance of the disk in its spectral energy distribution. We show that the observed morphology can be represented either as a highly eccentric ring around AK Sco, or as two separate spiral arms in the disk, wound in opposite directions. The relative merits of these interpretations are discussed, as well as whether these features may have been caused by one or several circumbinary planets interacting with the disk.

  5. Long noncoding RNA AK126698 inhibits proliferation and migration of non-small cell lung cancer cells by targeting Frizzled-8 and suppressing Wnt/β-catenin signaling pathway

    PubMed Central

    Fu, Xiao; Li, Hui; Liu, Chunxiao; Hu, Bin; Li, Tong; Wang, Yang

    2016-01-01

    Background Recent studies indicate that long noncoding RNAs (lncRNAs) play a key role in the control of cellular processes such as proliferation, metastasis, and differentiation. The lncRNA dysregulation has been identified in all types of cancer. We previously found that lncRNA AK126698 suppresses cisplatin resistance in A549 cells through the Wnt/β-catenin signaling pathway. However, the clinical significance of lncRNA AK126698 and the molecular mechanisms through which it regulates cancer cell proliferation and migration are largely unknown. Methods We examined the expression of lncRNA AK126698 in 56 non-small cell lung cancer (NSCLC) tissue samples and three NSCLC cell lines using quantitative real-time polymerase chain reaction. Gain and loss of function approaches were used to evaluate the biological function of AK126698 in NSCLC cells. The effects of lncRNA AK126698 on cell proliferation were investigated using cell counting kit-8 and 5-ethynyl-2′-deoxyuridine assays, and apoptosis was measured by flow cytometry. Protein levels of AK126698 targets were evaluated by Western blotting. Results Our results showed that lncRNA AK126698 was significantly downregulated in NSCLC tissues, compared with paired adjacent nontumor tissue samples. Furthermore, lower AK126698 expression was associated with larger tumor size and advanced tumor stage. Ectopic AK126698 expression inhibited cell proliferation and migration and induced apoptosis. Conversely, decreased AK126698 expression promoted cell proliferation and migration and inhibited cell apoptosis. Importantly, we demonstrated that Frizzled-8, a receptor of Wnt/β-catenin pathway, was a target of AK126698. Furthermore, AK126698 could inhibit the activation of Wnt/β-catenin pathway, which was demonstrated by measuring the expression levels of Axin1, β-catenin, c-myc, cyclin D1, and E-cadherin. Conclusion It was found in the study that lncRNA AK126698 inhibits the proliferation and migration of NSCLC cells by

  6. Quantum Computers

    DTIC Science & Technology

    2010-03-04

    1227–1230 (2009). 31. Olmschenk, S. et al. Quantum teleportation between distant matter qubits. Science 323, 486–489 (2009). 32. Dür, W., Briegel, H...REVIEWS Quantum computers T. D. Ladd1{, F. Jelezko2, R. Laflamme3,4,5, Y. Nakamura6,7, C. Monroe8,9 & J. L. O’Brien10 Over the past several decades... quantum information science has emerged to seek answers to the question: can we gain some advantage by storing, transmitting and processing

  7. Computer grants

    NASA Astrophysics Data System (ADS)

    The Computer and Information Science and Engineering Directorate of the National Science Foundation will offer educational supplements to CISE grants in Fiscal Year 1990. The purpose of the supplements is to establish closer links between CISE-supported research and undergraduate education and to accelerate transfer into the classroom of research results from work done under existing research grants. Any principal investigator with an active NSF research award from a program in the CISE Directorate can apply for an educational supplement. Proposals should be for creative activities to improve education, not for research.

  8. Computer vision

    NASA Technical Reports Server (NTRS)

    Gennery, D.; Cunningham, R.; Saund, E.; High, J.; Ruoff, C.

    1981-01-01

    The field of computer vision is surveyed and assessed, key research issues are identified, and possibilities for a future vision system are discussed. The problems of descriptions of two and three dimensional worlds are discussed. The representation of such features as texture, edges, curves, and corners are detailed. Recognition methods are described in which cross correlation coefficients are maximized or numerical values for a set of features are measured. Object tracking is discussed in terms of the robust matching algorithms that must be devised. Stereo vision, camera control and calibration, and the hardware and systems architecture are discussed.

  9. Computational crystallization.

    PubMed

    Altan, Irem; Charbonneau, Patrick; Snell, Edward H

    2016-07-15

    Crystallization is a key step in macromolecular structure determination by crystallography. While a robust theoretical treatment of the process is available, due to the complexity of the system, the experimental process is still largely one of trial and error. In this article, efforts in the field are discussed together with a theoretical underpinning using a solubility phase diagram. Prior knowledge has been used to develop tools that computationally predict the crystallization outcome and define mutational approaches that enhance the likelihood of crystallization. For the most part these tools are based on binary outcomes (crystal or no crystal), and the full information contained in an assembly of crystallization screening experiments is lost. The potential of this additional information is illustrated by examples where new biological knowledge can be obtained and where a target can be sub-categorized to predict which class of reagents provides the crystallization driving force. Computational analysis of crystallization requires complete and correctly formatted data. While massive crystallization screening efforts are under way, the data available from many of these studies are sparse. The potential for this data and the steps needed to realize this potential are discussed.

  10. Low fingertip temperature rebound measured by digital thermal monitoring strongly correlates with the presence and extent of coronary artery disease diagnosed by 64-slice multi-detector computed tomography.

    PubMed

    Ahmadi, Naser; Nabavi, Vahid; Nuguri, Vivek; Hajsadeghi, Fereshteh; Flores, Ferdinand; Akhtar, Mohammad; Kleis, Stanley; Hecht, Harvey; Naghavi, Morteza; Budoff, Matthew

    2009-10-01

    Previous studies showed strong correlations between low fingertip temperature rebound measured by digital thermal monitoring (DTM) during a 5 min arm-cuff induced reactive hyperemia and both the Framingham Risk Score (FRS), and coronary artery calcification (CAC) in asymptomatic populations. This study evaluates the correlation between DTM and coronary artery disease (CAD) measured by CT angiography (CTA) in symptomatic patients. It also investigates the correlation between CTA and a new index of neurovascular reactivity measured by DTM. 129 patients, age 63 +/- 9 years, 68% male, underwent DTM, CAC and CTA. Adjusted DTM indices in the occluded arm were calculated: temperature rebound: aTR and area under the temperature curve aTMP-AUC. DTM neurovascular reactivity (NVR) index was measured based on increased fingertip temperature in the non-occluded arm. Obstructive CAD was defined as >or=50% luminal stenosis, and normal as no stenosis and CAC = 0. Baseline fingertip temperature was not different across the groups. However, all DTM indices of vascular and neurovascular reactivity significantly decreased from normal to non-obstructive to obstructive CAD [(aTR 1.77 +/- 1.18 to 1.24 +/- 1.14 to 0.94 +/- 0.92) (P = 0.009), (aTMP-AUC: 355.6 +/- 242.4 to 277.4 +/- 182.4 to 184.4 +/- 171.2) (P = 0.001), (NVR: 161.5 +/- 147.4 to 77.6 +/- 88.2 to 48.8 +/- 63.8) (P = 0.015)]. After adjusting for risk factors, the odds ratio for obstructive CAD compared to normal in the lowest versus two upper tertiles of FRS, aTR, aTMP-AUC, and NVR were 2.41 (1.02-5.93), P = 0.05, 8.67 (2.6-9.4), P = 0.001, 11.62 (5.1-28.7), P = 0.001, and 3.58 (1.09-11.69), P = 0.01, respectively. DTM indices and FRS combined resulted in a ROC curve area of 0.88 for the prediction of obstructive CAD. In patients suspected of CAD, low fingertip temperature rebound measured by DTM significantly predicted CTA-diagnosed obstructive disease.

  11. Production and Characterization of Organic Solvent-Tolerant Cellulase from Bacillus amyloliquefaciens AK9 Isolated from Hot Spring.

    PubMed

    Irfan, Muhammad; Tayyab, Ammara; Hasan, Fariha; Khan, Samiullah; Badshah, Malik; Shah, Aamer Ali

    2017-01-27

    A cellulase-producing bacterium, designated as strain AK9, was isolated from a hot spring of Tatta Pani, Azad Kashmir, Pakistan. The bacterium was identified as Bacillus amyloliquefaciens through 16S rRNA sequencing. Cellulase from strain AK9 was able to liberate glucose from soluble cellulose and carboxymethyl cellulose (CMC). Enzyme was purified through size exclusion chromatography and a single band of ∼47 kDa was observed on sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). The enzyme was purified with recovery of 35.5%, 3.6-fold purity with specific activity of 31 U mg(-1). The purified cellulase retained its activity over a wide range of temperature (50-70 °C) and pH (3-7) with maximum stability at 60 °C and pH 5.0. The activity inhibited by ethylenediaminetetraacetic acid (EDTA), suggested that it was metalloenzyme. Diethyl pyrocarbonate (DEPC) and β-mercaptoethanol significantly inhibited cellulase activity that revealed the essentiality of histidine residues and disulfide bonds for its catalytic function. It was stable in non-ionic surfactants, in the presence of various metal ions, and in water-insoluble organic solvents. Approximately 9.1% of reducing sugar was released after enzymatic saccharification of DAP-pretreated agro-residue, compared to a very low percentage by autohydrolysis treatment. Hence, it is concluded that cellulase from B. amyloliquefaciens AK9 can potentially be used in bioconversion of lignocellulosic biomass to fermentable sugars.

  12. Strain-Driven Approach to Quantum Criticality in AFe_{2}As_{2} with A=K, Rb, and Cs.

    PubMed

    Eilers, Felix; Grube, Kai; Zocco, Diego A; Wolf, Thomas; Merz, Michael; Schweiss, Peter; Heid, Rolf; Eder, Robert; Yu, Rong; Zhu, Jian-Xin; Si, Qimiao; Shibauchi, Takasada; Löhneysen, Hilbert V

    2016-06-10

    The iron-based superconductors AFe_{2}As_{2} with A=K, Rb, Cs exhibit large Sommerfeld coefficients approaching those of heavy-fermion systems. We have investigated the magnetostriction and thermal expansion of this series to shed light on this unusual behavior. Quantum oscillations of the magnetostriction allow identifying the band-specific quasiparticle masses which by far exceed the band-structure derived masses. The divergence of the Grüneisen ratio derived from thermal expansion indicates that with increasing volume along the series a quantum critical point is approached. The critical fluctuations responsible for the enhancement of the quasiparticle masses appear to weaken the superconducting state.

  13. Computational introspection

    SciTech Connect

    Batali, J.

    1983-02-01

    Introspection is the process of thinking about one's own thoughts and feelings. In this paper, the author discusses recent attempts to make computational systems that exhibit introspective behavior. Each presents a system capable of manipulating representations of its own program and current context. He argues that introspective ability is crucial for intelligent systems--without it an agent cannot represent certain problems that it must be able to solve. A theory of intelligent action would describe how and why certain actions intelligently achieve an agent's goals. The agent would both embody and represent this theory: it would be implemented as the program for the agent; and the importance of introspection suggests that the agent represent its theory of action to itself.

  14. Computer vision

    SciTech Connect

    Not Available

    1982-01-01

    This paper discusses material from areas such as artificial intelligence, psychology, computer graphics, and image processing. The intent is to assemble a selection of this material in a form that will serve both as a senior/graduate-level academic text and as a useful reference to those building vision systems. This book has a strong artificial intelligence flavour, emphasising the belief that both the intrinsic image information and the internal model of the world are important in successful vision systems. The book is organised into four parts, based on descriptions of objects at four different levels of abstraction. These are: generalised images-images and image-like entities; segmented images-images organised into subimages that are likely to correspond to interesting objects; geometric structures-quantitative models of image and world structures; relational structures-complex symbolic descriptions of image and world structures. The book contains author and subject indexes.

  15. Computational micromechanics

    NASA Astrophysics Data System (ADS)

    Ortiz, M.

    1996-09-01

    Selected issues in computational micromechanics are reviewed, with particular emphasis on multiple-scale problems and micromechanical models of material behavior. Examples considered include: the bridging of atomistic and continuum scales, with application to nanoindentation and the brittle-to-ductile transition; the development of dislocation-based constitutive relations for pure metallic crystals and intermetallic compounds, with applications to fracture of single crystals and bicrystals; the simulation of non-planar three-dimensional crack growth at the microscale, with application to mixed mode I III effective behavior and crack trapping and bridging in fiber-reinforced composites; and the direct micromechanical simulation of fragmentation of brittle solids and subsequent flow of the comminuted phase.

  16. Monte Carlo calculation of patient organ doses from computed tomography.

    PubMed

    Oono, Takeshi; Araki, Fujio; Tsuduki, Shoya; Kawasaki, Keiichi

    2014-01-01

    In this study, we aimed to evaluate quantitatively the patient organ dose from computed tomography (CT) using Monte Carlo calculations. A multidetector CT unit (Aquilion 16, TOSHIBA Medical Systems) was modeled with the GMctdospp (IMPS, Germany) software based on the EGSnrc Monte Carlo code. The X-ray spectrum and the configuration of the bowtie filter for the Monte Carlo modeling were determined from the chamber measurements for the half-value layer (HVL) of aluminum and the dose profile (off-center ratio, OCR) in air. The calculated HVL and OCR were compared with measured values for body irradiation with 120 kVp. The Monte Carlo-calculated patient dose distribution was converted to the absorbed dose measured by a Farmer chamber with a (60)Co calibration factor at the center of a CT water phantom. The patient dose was evaluated from dose-volume histograms for the internal organs in the pelvis. The calculated Al HVL was in agreement within 0.3% with the measured value of 5.2 mm. The calculated dose profile in air matched the measured value within 5% in a range of 15 cm from the central axis. The mean doses for soft tissues were 23.5, 23.8, and 27.9 mGy for the prostate, rectum, and bladder, respectively, under exposure conditions of 120 kVp, 200 mA, a beam pitch of 0.938, and beam collimation of 32 mm. For bones of the femur and pelvis, the mean doses were 56.1 and 63.6 mGy, respectively. The doses for bone increased by up to 2-3 times that of soft tissue, corresponding to the ratio of their mass-energy absorption coefficients.

  17. Characterization of Arctic elemental carbon in Barrow, AK using radiocarbon source apportionment

    NASA Astrophysics Data System (ADS)

    Barrett, T. E.; Usenko, S.; Robinson, E. M.; Sheesley, R. J.

    2013-12-01

    Currently, the Arctic is one of the fastest warming regions on earth with surface temperatures increasing at a rate nearly double the global mean over recent decades. Despite the fact that atmospheric concentrations of elemental carbon (EC) are lower in the Arctic than in lower latitudes, deposition of EC on snow and ice may exacerbate regional warming by simultaneously decreasing albedo and increasing melt rates. Due to the intensifying Arctic oil exploration in areas such as the Beaufort and Chukchi seas, the impact of new emission sources such as heavy fuel and heavy diesel combustion on regional carbon needs to be assessed. The first step in developing mitigation strategies for reducing current and future EC emissions in the Arctic is to determine emission source contributions. This study aims to determine the relative contributions of fossil fuel and biomass combustion and to identify major source regions of EC to the Arctic. Radiocarbon analysis of both total organic carbon (TOC) and EC combined with organic tracer and back trajectory analysis has been applied to a set of wintertime coarse particulate matter (PM10) samples from Barrow, AK. Preliminary apportionment for January 2013 indicates roughly half of TOC is from biogenic/biomass burning emissions and one third of EC is due to biomass burning emissions. The radiocarbon results will be combined with organic tracer analysis (polycyclic aromatic hydrocarbons, petroleum biomarkers and normal alkanes), increasing the specificity of the relative contribution of both the fossil and modern (biogenic/biomass burning) carbon emission sources. This research represents the first reported radiocarbon values for Arctic EC, providing highly conclusive source apportionment prior to the influence of increased drilling operations and ship traffic in the Beaufort and Chukchi seas.

  18. Quantitative defect in staphylococcal enterotoxin A binding and presentation by HLA-DM-deficient T2.Ak cells corrected by transfection of HLA-DM genes.

    PubMed

    Albert, L J; Denzin, L K; Ghumman, B; Bangia, N; Cresswell, P; Watts, T H

    1998-01-10

    HLA-DM facilitates peptide acquisition by MHC class II proteins within the endosomes of APC by facilitating release of invariant chain peptide intermediates (CLIP) from the class II molecules. T2 cells have a deletion in the MHC II region which deletes HLA-DM and MHC II genes. T2 cells transfected with MHC class II proteins are defective in protein presentation, a defect that is corrected by HLA-DM transfection. Here we show that T2 cells transfected with Ak are also impaired in binding and presentation of the superantistaphylococcal enterotoxin A and that HLA-DM transfection corrects this defect. The poor ability of SEA to bind to Ak on DM-deficient cells is somewhat surprising since Ak has a low affinity for CLIP and is not predominantly occupied with CLIP on T2 cells compared to wide-type APC. These data suggest an influence of HLA-DM on the structure or composition of the Ak/peptide complex beyond its role in the release of invariant chain peptides.

  19. Independent selection by I-Ak molecules of two epitopes found in tandem in an extended polypeptide antigen.

    PubMed

    Gugasyan, R; Velazquez, C; Vidavsky, I; Deck, B M; van der Drift, K; Gross, M L; Unanue, E R

    2000-09-15

    The protein hen egg white lysozyme (HEL) contains two segments, in tandem, from which two families of peptides are selected by the class II molecule I-Ak, during processing. These encompass peptides primarily from residues 31-47 and 48-63. Mutant HEL proteins were created with changes in residues 52 and 55, resulting in a lack of binding and selection of the 48-63 peptides to I-Ak molecules. Such mutant HEL proteins donated the same amount of 31-47 peptide as did the unmodified protein. Other mutant HEL molecules containing proline residues at residue 46, 47, or 48 resulted in extensions of the selected 31-47 or 48-62 families to their overlapping regions (in the carboxyl or amino termini, respectively). However, the amount of each family of peptide selected was not changed. We conclude that the presence or absence of the major peptide from HEL does not influence the selection of other epitopes, and that these two families are selected independently of each other.

  20. Transcriptional response of Desulfatibacillum alkenivorans AK-01 to growth on alkanes: insights from RT-qPCR and microarray analyses.

    PubMed

    Herath, Anjumala; Wawrik, Boris; Qin, Yujia; Zhou, Jizhong; Callaghan, Amy V

    2016-05-01

    Microbial transformation of n-alkanes in anaerobic ecosystems plays a pivotal role in biogeochemical carbon cycling and bioremediation, but the requisite genetic machinery is not well elucidated.Desulfatibacillum alkenivorans AK-01 utilizes n-alkanes (C13 to C18) and contains two genomic loci encoding alkylsuccinate synthase (ASS) gene clusters. ASS catalyzes alkane addition to fumarate to form methylalkylsuccinic acids. We hypothesized that the genes in the two clusters would be differentially expressed depending on the alkane substrate utilized for growth. RT-qPCR was used to investigate ass-gene expression across AK-01's known substrate range, and microarray-based transcriptomic analysis served to investigate whole-cell responses to growth on n-hexadecane versus hexadecanoate. RT-qPCR revealed induction of ass gene cluster 1 during growth on all tested alkane substrates, and the transcriptional start sites in cluster 1 were determined via 5'RACE. Induction of ass gene cluster 2 was not observed under the tested conditions. Transcriptomic analysis indicated that the upregulation of genes potentially involved in methylalkylsuccinate metabolism, including methylmalonyl-CoA mutase and a putative carboxyl transferase. These findings provide new directions for studying the transcriptional regulation of genes involved in alkane addition to fumarate, fumarate recycling and the processing of methylalkylsuccinates with regard to isolates, enrichment cultures and ecological datasets.

  1. Post-mortem computed tomography and 3D imaging: anthropological applications for juvenile remains.

    PubMed

    Brough, Alison L; Rutty, Guy N; Black, Sue; Morgan, Bruno

    2012-09-01

    Anthropological examination of defleshed bones is routinely used in medico-legal investigations to establish an individual's biological profile. However, when dealing with the recently deceased, the removal of soft tissue from bone can be an extremely time consuming procedure that requires the presence of a trained anthropologist. In addition, due to its invasive nature, in some disaster victim identification scenarios the maceration of bones is discouraged by religious practices and beliefs, or even prohibited by national laws and regulations. Currently, three different radiological techniques may be used in the investigative process; plain X-ray, dental X-ray and fluoroscopy. However, recent advances in multi-detector computed tomography (MDCT) mean that it is now possible to acquire morphological skeletal information from high resolution images, reducing the necessity for invasive procedures. This review paper considers the possible applications of a virtual anthropological examination by reviewing the main juvenile age determination methods used by anthropologists at present and their possible adaption to MDCT.

  2. Assessing vertebral fracture risk on volumetric quantitative computed tomography by geometric characterization of trabecular bone structure

    NASA Astrophysics Data System (ADS)

    Checefsky, Walter A.; Abidin, Anas Z.; Nagarajan, Mahesh B.; Bauer, Jan S.; Baum, Thomas; Wismüller, Axel

    2016-03-01

    The current clinical standard for measuring Bone Mineral Density (BMD) is dual X-ray absorptiometry, however more recently BMD derived from volumetric quantitative computed tomography has been shown to demonstrate a high association with spinal fracture susceptibility. In this study, we propose a method of fracture risk assessment using structural properties of trabecular bone in spinal vertebrae. Experimental data was acquired via axial multi-detector CT (MDCT) from 12 spinal vertebrae specimens using a whole-body 256-row CT scanner with a dedicated calibration phantom. Common image processing methods were used to annotate the trabecular compartment in the vertebral slices creating a circular region of interest (ROI) that excluded cortical bone for each slice. The pixels inside the ROI were converted to values indicative of BMD. High dimensional geometrical features were derived using the scaling index method (SIM) at different radii and scaling factors (SF). The mean BMD values within the ROI were then extracted and used in conjunction with a support vector machine to predict the failure load of the specimens. Prediction performance was measured using the root-mean-square error (RMSE) metric and determined that SIM combined with mean BMD features (RMSE = 0.82 +/- 0.37) outperformed MDCT-measured mean BMD (RMSE = 1.11 +/- 0.33) (p < 10-4). These results demonstrate that biomechanical strength prediction in vertebrae can be significantly improved through the use of SIM-derived texture features from trabecular bone.

  3. Scanning protocol optimization and dose evaluation in coronary stenosis using multi-slices computed tomography

    NASA Astrophysics Data System (ADS)

    Huang, Yung-hui; Chen, Chia-lin; Sheu, Chin-yin; Lee, Jason J. S.

    2007-02-01

    Cardiovascular diseases are the most common incidence for premature death in developed countries. A major fraction is attributable to atherosclerotic coronary artery disease, which may result in sudden cardiac failure. A reduction of mortality caused by myocardial infarction may be achieved if coronary atherosclerosis can be detected and treated at an early stage before symptoms occur. Therefore, there is need for an effective tool that allows identification of patients at increased risk for future cardiac events. The current multi-detector CT has been widely used for detection and quantification of coronary calcifications as a sign of coronary atherosclerosis. The aim of this study is to optimize the diagnostic values and radiation exposure in coronary artery calcium-screening examination using multi-slice CT (MSCT) with different image scan protocols. The radiation exposure for all protocols is evaluated by using computed tomography dose index (CTDI) phantom measurements. We chose an optimal scanning protocol and evaluated patient radiation dose in the MSCT coronary artery screenings and preserved its expecting diagnostic accuracy. These changes make the MSCT have more operation flexibility and provide more diagnostic values in current practice.

  4. Complex anatomy surrounding the left atrial posterior wall: analysis with 3D computed tomography.

    PubMed

    Maeda, Shingo; Iesaka, Yoshito; Uno, Kikuya; Otomo, Kiyoshi; Nagata, Yasutoshi; Suzuki, Kenji; Hachiya, Hitoshi; Goya, Masahiko; Takahashi, Atsushi; Fujiwara, Hideomi; Hiraoka, Masayasu; Isobe, Mitsuaki

    2012-01-01

    Few studies have explored the topographic anatomy of the esophagus, posterior wall of the left atrium (LA), or fat pads using multidetector computed tomography (MDCT) to prevent the risk of esophageal injury during atrial fibrillation (AF) ablation. MDCT was performed in 110 consecutive patients with paroxysmal or persistent AF before the ablation procedure to understand the anatomic relationship of the esophagus. Two major types of esophagus routes were demonstrated. Leftward (type A) and rightward (type B) routes were found in 90 and 10% of the patients, respectively. A type A route had a larger mean size of the LA than type B. The fat pad was identifiable at the level of the inferior pulmonary vein in 91% of the patients without any predominance of either type. The thickness of the fat pad was thinner in the patients with a dilated LA (>42 mm) than in those with a normal LA size (≤42 mm) (p = 0.01). The results demonstrated that the majority of cases had a leftward route of the esophagus. There was a close association between the LA dilatation and fat pad thinning. With a dilated LA, the esophagus may become easily susceptible to direct thermal injury during AF ablation. Visualization of the anatomic relationship may contribute to the prevention of the potential risk of an esophageal injury.

  5. Effective Doses in Four-Dimensional Computed Tomography for Lung Radiotherapy Planning

    SciTech Connect

    Mori, Shinichiro Ko, Susumu; Ishii, Takayoshi; Nishizawa, Kanae

    2009-04-01

    The recent broad adoption of 4-D computed tomography (4DCT) scanning in radiotherapy has allowed the accurate determination of the target volume of tumors by minimizing image degradation caused by respiratory motion. Although the radiation exposure of the treatment beam is significantly greater than that of CT scans used for treatment planning, it is important to recognize and optimize the radiation exposure in 4DCT from the radiological protection point of view. Here, radiation exposure in 4DCT was measured with a 16 multidetector CT. Organ doses were measured using thermoluminescence radiation dosimeter chips inserted at respective anatomical sites of an anthropomorphic phantom. Results were compared with those with the helical CT scan mode. The effective dose measured for 4DCT was 24.7 mSv, approximately four times higher than that for helical CT. However, the increase in treatment accuracy afforded by 4DCT means its use in radiotherapy is inevitable. The patient exposure in the 4DCT could be of value by clarifying the advantage of the treatment planning using 4DCT.

  6. Specialized computer architectures for computational aerodynamics

    NASA Technical Reports Server (NTRS)

    Stevenson, D. K.

    1978-01-01

    In recent years, computational fluid dynamics has made significant progress in modelling aerodynamic phenomena. Currently, one of the major barriers to future development lies in the compute-intensive nature of the numerical formulations and the relative high cost of performing these computations on commercially available general purpose computers, a cost high with respect to dollar expenditure and/or elapsed time. Today's computing technology will support a program designed to create specialized computing facilities to be dedicated to the important problems of computational aerodynamics. One of the still unresolved questions is the organization of the computing components in such a facility. The characteristics of fluid dynamic problems which will have significant impact on the choice of computer architecture for a specialized facility are reviewed.

  7. Utility of cone-beam computed tomography in the assessment of the porto-spleno-mesenteric venous system

    PubMed Central

    2016-01-01

    The common diagnostic tools available to evaluate the porto-spleno-mesenteric venous (PSMV) system provide either good hemodynamic information with limited morphological details [e.g., ultrasonography (US)] or excellent tomographic display of the anatomy with limited information about flow patterns [e.g., multidetector computed tomography (MDCT) and magnetic resonance imaging]. Although catheter-directed selective digital subtraction angiography (DSA) can provide excellent information about flow at a high temporal resolution and can generate images at a high spatial resolution, this technique is often limited by a lack of cross-sectional detail. In the assessment of the PSMV system, DSA is also limited by dilution of contrast and motion artefacts. Combining venous phase cone-beam computed tomography (CBCT) with DSA can generate high-quality tomographic data, which allows detailed evaluation of venous tributaries and flow patterns within the splenic, superior mesenteric, and inferior mesenteric venous systems individually. This enables clinicians to better understand the impact of nonobstructive resistance to flow (e.g., as in patients with cirrhosis) and obstructive resistance to flow (e.g., as in patients with thrombosis) within each system and plan treatment accordingly. In this review, we discuss the limitations of common diagnostic methods and the role venous CBCT in combination with DSA can play in assessing the PSMV system. PMID:28123975

  8. Integrated Airborne and In-Situ Measurements Over Land-Fast Ice Near Barrow, AK.

    NASA Astrophysics Data System (ADS)

    Gardner, J. M.; Brozena, J. M.; Richter-Menge, J.; Abelev, A.; Liang, R.; Ball, D.; Claffey, K. J.; Hebert, D. A.; Jones, K.

    2015-12-01

    The Naval Research Laboratory has collected two field seasons of integrated airborne and in-situ measurements over multiple sites of floating, but land-fast ice north of Barrow, AK. During the first season in March of 2014 the Cold Regions Research and Engineering Laboratory led the on-ice group including NRL personnel and Naval Academy midshipmen. The second season (March 2015) included only NRL scientists and midshipmen. The in-situ data provided ground-truth for airborne measurements from a scanning LiDAR (Riegl Q 560i), digital photogrammetry (Applanix DSS-439), a low-frequency SAR (P-band in 2014 and P and L bands in 2015) and a snow/Ku radar procured from the Center for Remote Sensing of Ice Sheets of the University of Kansas. The CReSIS radar was updated in 2015 to integrate the snow and Ku radars into a single continuous chirp, thus improving resolution. The objective of the survey was to aid our understanding of the use of the airborne data to calibrate/validate Cryosat-2 data. Sampling size or "footprint" plays a critical role in the attempt to compare in-situ measurements with airborne (or satellite) measurements. Thus the in-situ data were arranged to minimize aliasing. Ground measurements were collected along transects a sites generally consisting of a 2 km long profile of Magnaprobe and EM31 measurements with periodic boreholes. A 60 m x 400 m swath of Magnaprobe measurements was centered on this profile. Airborne data were collected on multiple overflights of the transect areas. The LiDAR measured total freeboard (ice + snow) referenced to leads in the ice, and produced swaths 200-300 m wide. The SAR imaged the ice beneath the snow and the snow/Ku radar measured snow thickness. The freeboard measurements and snow thickness are used to estimate ice thickness via isostasy and density estimates. Comparisons and processing methodology will be shown. The results of this ground-truth experiment will inform our analysis of grids of airborne data collected

  9. Integrated Airborne and In-Situ Measurements over Land-Fast Ice near Barrow, AK.

    NASA Astrophysics Data System (ADS)

    Brozena, J. M.; Gardner, J. M.; Liang, R.; Ball, D.; Richter-Menge, J.; Claffey, K. J.; Abelev, A.; Hebert, D. A.; Jones, K.

    2014-12-01

    During March of 2014, the Naval Research Laboratory and the Cold Regions Research and Engineering Laboratory collected an integrated set of airborne and in-situ measurements over two areas of floating, but land-fast ice near the coast of Barrow, AK. The near-shore site was just north of Point Barrow, and the "offshore" site was ~ 20 km east of Point Barrow. The in-situ data provided ground-truth for airborne measurements from a scanning LiDAR (Riegl Q 560i), digital photogrammetry (Applanix DSS-439) and a snow radar procured from the Center for Remote Sensing of Ice Sheets of the University of Kansas. The objective of the survey was to aid our understanding of the use of the airborne data to calibrate/validate Cryosat-2 data. Sampling size or "footprint" plays a critical role in the attempt to compare in-situ measurements with airborne (or satellite) measurements. Thus the in-situ data were arranged to minimize aliasing. Ground measurements were collected along transects at both sites consisting of a 2 km long profile of snow depth and ice thickness measurements with periodic boreholes. A 60 m x 400 m swath of snow depth measurements was centered on this profile. Airborne data were collected on five overflights of the two transect areas. The LiDAR measured total freeboard (ice + snow) referenced to leads in the ice, and produced swaths 200-300 m wide. The radar measured snow thickness. The freeboard and snow thickness measurements are used to estimate ice thickness via isostasy and density estimates. The central swath of in situ snow depth data allows examination of the effects of cross-track variations considering the relatively large footprint of the snow radar. Assuming a smooth, flat surface the radar range resolution in air is < 4 cm, but the along-track sampling distance is ~ 3 m after unfocussed SAR processing. The width of the footprint varies from ~ 9 m up to about 40 m (beam-limited) for uneven surfaces. However, the radar could not resolve snow thickness

  10. Program Facilitates Distributed Computing

    NASA Technical Reports Server (NTRS)

    Hui, Joseph

    1993-01-01

    KNET computer program facilitates distribution of computing between UNIX-compatible local host computer and remote host computer, which may or may not be UNIX-compatible. Capable of automatic remote log-in. User communicates interactively with remote host computer. Data output from remote host computer directed to local screen, to local file, and/or to local process. Conversely, data input from keyboard, local file, or local process directed to remote host computer. Written in ANSI standard C language.

  11. Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study

    PubMed Central

    Tang, Kun; Wang, Ling; Li, Rui; Lin, Jie; Zheng, Xiangwu; Cao, Guoquan

    2012-01-01

    Purpose. To investigate the effect of low tube voltage (80 kV) on image quality, radiation dose, and low-contrast detectability (LCD) at abdominal computed tomography (CT). Materials and Methods. A phantom containing low-contrast objects was scanned with a CT scanner at 80 and 120 kV, with tube current-time product settings at 150–650 mAs. The differences between image noise, contrast-to-noise ratio (CNR), and scores of LCD obtained with 80 kV at 150–650 mAs and those obtained with 120 kV at 300 mAs were compared respectively. Results. The image noise substantially increased with low tube voltage. However, with identical dose, use of 80 kV resulted in higher CNR compared with CNR at 120 kV. There were no statistically significant difference in CNR and scores of LCD between 120 kV at 300 mAs and 80 kV at 550–650 mAs (P > 0.05). The relative dose delivered at 80 kV ranged from 58% at 550 mAs to 68% at 650 mAs. Conclusion. With a reduction of the tube voltage from 120 kV to 80 kV at abdominal CT, the radiation dose can be reduced by 32% to 42% without degradation of CNR and LCD. PMID:22619490

  12. CAA: Computer Assisted Athletics.

    ERIC Educational Resources Information Center

    Hall, John H.

    Computers have been used in a variety of applications for athletics since the late 1950's. These have ranged from computer-controlled electric scoreboards to computer-designed pole vaulting poles. Described in this paper are a computer-based athletic injury reporting system and a computer-assisted football scouting system. The injury reporting…

  13. The assumptions of computing

    SciTech Connect

    Huggins, J.K.

    1994-12-31

    The use of computers, like any technological activity, is not content-neutral. Users of computers constantly interact with assumptions regarding worthwhile activity which are embedded in any computing system. Directly questioning these assumptions in the context of computing allows us to develop an understanding of responsible computing.

  14. Democratizing Computer Science

    ERIC Educational Resources Information Center

    Margolis, Jane; Goode, Joanna; Ryoo, Jean J.

    2015-01-01

    Computer science programs are too often identified with a narrow stratum of the student population, often white or Asian boys who have access to computers at home. But because computers play such a huge role in our world today, all students can benefit from the study of computer science and the opportunity to build skills related to computing. The…

  15. The Old Computers' Home.

    ERIC Educational Resources Information Center

    Angier, Natalie

    1983-01-01

    The Computer Museum in Marlborough, Massachusetts houses old and not-so-old calculators, famous old computers and parts of computers, photographs and assorted memorabilia, computer-generated murals, and even a computer made of Tinkertoys that plays tick-tack-toe. The development of the museum and selected exhibits is described. (Author/JN)

  16. Computing the Profession.

    ERIC Educational Resources Information Center

    Denning, Peter J.

    1998-01-01

    Discussion of computing as a science and profession examines the chasm between computer scientists and users, barriers to the use and growth of computing, experimental computer science, computational science, software engineering, professional identity, professional practices, applications of technology, innovation, field boundaries, and…

  17. Tying into Computers.

    ERIC Educational Resources Information Center

    Canipe, Stephen L.

    Topics in this paper include: sources of computer programs, public domain software, copyright violations, purposes of computers in classrooms (drill/practice and interactive learning), computer assisted instruction, flow charts, and computer clubs (such as App-le-kations in Charlotte, North Carolina). A complete listing of two computer programs…

  18. Computational thinking and thinking about computing

    PubMed Central

    Wing, Jeannette M.

    2008-01-01

    Computational thinking will influence everyone in every field of endeavour. This vision poses a new educational challenge for our society, especially for our children. In thinking about computing, we need to be attuned to the three drivers of our field: science, technology and society. Accelerating technological advances and monumental societal demands force us to revisit the most basic scientific questions of computing. PMID:18672462

  19. Intraindividual comparison of gadolinium- and iodine-enhanced 64-slice multidetector CT pulmonary angiography for the detection of pulmonary embolism in a porcine model.

    PubMed

    Henes, Frank Oliver Gerhard; Groth, Michael; Begemann, Philipp G C; Adam, Gerhard; Regier, Marc

    2011-06-01

    This study is an evaluation of the diagnostic accuracy of gadolinium-enhanced computed tomography pulmonary angiography (CTPA) for the detection of pulmonary embolism (PE) in comparison with iodine-enhanced CTPA. PE was induced in five anesthetized pigs by administration of blood clots through an 11-F catheter inside the jugular vein. Animals underwent CTPA in breathhold with i.v. bolus injection of 50 ml gadopentetate dimeglumine (0.4 mmol/kg, 4 ml/s). Subsequently, CTPA was performed using the same imaging parameters but under administration of 70 ml nonionic iodinated contrast material (400 mg/ml, 4 ml/s). All images were reconstructed with 1 mm slice thickness. A consensus readout of the iodium-enhanced CTPAs by both radiologists served as reference standard. Gadolinium-enhanced CTPAs were evaluated independently by two experienced radiologists, and differences in detection rate between both contrast agents were assessed on a per embolus basis using the Wilcoxon signed-rank test. Interobserver agreement was determined by calculation of қ values. PE was diagnosed independently by both readers in all five pigs by the use of gadolinium-enhanced CTPA. Out of 60 pulmonary emboli detected in the iodine-enhanced scans, 47 (78.3%; reader 1) and 44 (62.8%; reader 2) emboli were detected by the use of gadolinium. All 13 (100%) emboli in lobar arteries (by both readers) and 26 (reader 1) and 25 (reader 2) out of 27 emboli (96.3% and 92.6%) in segmental arteries were detected by the use of the gadolinium-enhanced CTPA. In subsegmental arteries, only 8 (40%; reader 1) and 6 (30%; reader 2) out of 20 emboli were detected by the gadolinium-enhanced CTPA. By comparing both scans on a per vessel basis (Wilcoxon test), Gd-enhanced CTPA was significantly inferior in emboli detection on subsegmental level (P < 0.0001). The interobserver agreement was excellent on lobar and segmental level (қ = 1.0 and 0.93, respectively), whereas readers only reached moderate

  20. The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: A Monte Carlo study

    SciTech Connect

    Tzedakis, Antonis; Perisinakis, Kostas; Raissaki, Maria; Damilakis, John

    2006-07-15

    The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volume boundaries. This information was used to simulate CT exposures by Monte Carlo code. The Monte Carlo N-Particle (MCNP, version 4C2) radiation transport code and five mathematical anthropomorphic phantoms representing newborn, 1-, 5-, 10-, and 15-year-old patient, were employed in the current study. To estimate effective dose, the weighted computed tomography dose index was calculated by cylindrical polymethyl-methacrylate phantoms of 9.7, 13.1, 15.4, 16.1, and 16.9 cm in diameter representing the pediatric head of newborn, 1-, 5-, 10-, and 15-year-old individuals, respectively. The validity of the Monte Carlo calculated approach was verified by comparison with dose data obtained using physical pediatric anthropomorphic phantoms and thermoluminescence dosimetry. For all patients studied, the eye lenses were located in the region -1 to 3 cm from the first slice of the imaged volume. Doses from axial scans were always lower than those from corresponding helical examinations. The percentage differences in normalized eye lens absorbed dose between contiguous axial and helical examinations with pitch=1 were found to be up to 10.9%, when the eye lenses were located inside the region to be imaged. When the eye lenses were positioned 0-3 cm far from the first slice of region to be imaged, the normalized dose to the lens from contiguous axial examinations was up to 11 times lower than the corresponding values from helical mode with pitch=1. The effective dose from axial examinations was up to 24% lower than corresponding values from helical examinations with pitch=1. In conclusion, it is more dose efficient to use axial mode acquisition rather than helical scan