Science.gov

Sample records for ak multidetector computed

  1. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    MedlinePlus

    ... High Blood Pressure Tools & Resources Stroke More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 3,2015 ... facts MDCT is a very fast type of computed tomography (CT) scan. MDCT creates pictures of the healthy ...

  2. Multidetector computer tomography: evaluation of blunt chest trauma in adults.

    PubMed

    Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall. PMID:25295188

  3. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    PubMed Central

    Matos, António P.; Mascarenhas, Vasco; Herédia, Vasco

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall. PMID:25295188

  4. Multidetector computer tomography: evaluation of blunt chest trauma in adults.

    PubMed

    Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  5. [The different manifestations of pulmonary aspergillosis: multidetector computed tomography findings].

    PubMed

    Koren Fernández, L; Alonso Charterina, S; Alcalá-Galiano Rubio, A; Sánchez Nistal, M A

    2014-01-01

    Pulmonary aspergillosis is a fungal infection usually caused by inhaling Aspergillus fumigatus spores. However, when we talk about aspergillosis, we normally refer to the spectrum of clinical and radiological findings that depend directly on the patient's immune status, on the prior existence of lung disease, and on the virulence of the infective organism. There are four types of pulmonary aspergillosis (aspergilloma, allergic bronchopulmonary aspergillosis, chronic necrotizing pulmonary aspergillosis, and invasive aspergillosis), and each type has its own distinct radiologic findings. We review the signs of pulmonary aspergillosis on multidetector computed tomography and we correlate them with patients' symptoms and immune responses. Likewise, we discuss the differential diagnoses.

  6. Perforated Appendicitis: Assessment With Multidetector Computed Tomography.

    PubMed

    Iacobellis, Francesca; Iadevito, Isabella; Romano, Federica; Altiero, Michele; Bhattacharjee, Bikram; Scaglione, Mariano

    2016-02-01

    Appendicitis is one of the most common abdominal surgical emergencies. In some cases, the correct diagnosis may be challenging, owing to different conditions that can mimic this pathology. In this context, abdominal computed tomography (CT) is the imaging modality of choice, leading to an accurate diagnosis and to a reduction in unnecessary laparotomies. The diagnosis of perforated appendix is crucial, but the detection of the perforation signs by CT may not be so simple in the early process. The aim of this article is to review the multiple detector CT signs of perforated appendicitis.

  7. Multidetector Computed Tomography for Congenital Anomalies of the Aortic Arch: Vascular Rings.

    PubMed

    García-Guereta, Luis; García-Cerro, Estefanía; Bret-Zurita, Montserrat

    2016-07-01

    The development of multidetector computed tomography has triggered a revolution in the study of the aorta and other large vessels and has replaced angiography in the diagnosis of congenital anomalies of the aortic arch, particularly vascular rings. The major advantage of multidetector computed tomography is that it permits clear 3-dimensional assessment of not only vascular structures, but also airway and esophageal compression. The current update aims to summarize the embryonic development of the aortic arch and the developmental anomalies leading to vascular ring formation and to discuss the current diagnostic and therapeutic role of multidetector computed tomography in this field.

  8. Multidetector computed tomography of temporomandibular joint: A road less travelled

    PubMed Central

    Pahwa, Shivani; Bhalla, Ashu Seith; Roychaudhary, Ajoy; Bhutia, Ongkila

    2015-01-01

    This article reviews the imaging anatomy of temporomandibular joint (TMJ), describes the technique of multi-detector computed tomography (MDCT) of the TMJ, and describes in detail various osseous pathologic afflictions affecting the joint. Traumatic injuries affecting the mandibular condyle are most common, followed by joint ankylosis as a sequel to arthritis. The congenital anomalies are less frequent, hemifacial microsomia being the most commonly encountered anomaly involving the TMJ. Neoplastic afflictions of TMJ are distinctly uncommon, osteochondroma being one of the most common lesions. MDCT enables comprehensive evaluation of osseous afflictions of TMJ, and is a valuable tool for surgical planning. Sagittal, coronal and 3D reformatted images well depict osseous TMJ lesions, and their relationship to adjacent structures. PMID:25984518

  9. Multidetector-row computed tomography in cerebral hydatid cyst

    PubMed Central

    Wani, Nisar A; Kosar, Tasleem L; Khan, Abdul Qayum; Ahmad, Sheikh Shahnawaz

    2010-01-01

    Intracranial localization is a rare manifestation of hydatid cyst disease (Echinococcosis). It comprises only 2% of cases of Echinococcosis infection even in endemic areas and is predominantly seen in children. Clinical manifestations resulting from raised intracranial tension are nonspecific. Imaging with computed tomography (CT) may suggest the diagnosis preoperatively with reasonable accuracy. Multidetector-row CT (MDCT) with its high resolution multiplanar reformations can demonstrate the relationship of the cyst with adjacent brain structures and thus help in planning surgery. This has a practical utility in places where magnetic resonance imaging is not available. We describe a case of cerebral hydatid cyst in a 13-year-old boy who was diagnosed with MDCT, which helped in planning its surgical removal. PMID:21808517

  10. Acute Perforated Diverticulitis: Assessment With Multidetector Computed Tomography.

    PubMed

    Sessa, Barbara; Galluzzo, Michele; Ianniello, Stefania; Pinto, Antonio; Trinci, Margherita; Miele, Vittorio

    2016-02-01

    Colonic diverticulitis is a common condition in the western population. Complicated diverticulitis is defined as the presence of extraluminal air or abscess, peritonitis, colon occlusion, or fistulas. Multidetector row computed tomography (MDCT) is the modality of choice for the diagnosis and the staging of diverticulitis and its complications, which enables performing an accurate differential diagnosis and addressing the patients to a correct management. MDCT is accurate in diagnosing the site of perforation in approximately 85% of cases, by the detection of direct signs (focal bowel wall discontinuity, extraluminal gas, and extraluminal enteric contrast) and indirect signs, which are represented by segmental bowel wall thickening, abnormal bowel wall enhancement, perivisceral fat stranding of fluid, and abscess. MDCT is accurate in the differentiation from complicated colon diverticulitis and colon cancer, often with a similar imaging. The computed tomography-guided classification is recommended to discriminate patients with mild diverticulitis, generally treated with antibiotics, from those with severe diverticulitis with a large abscess, which may be drained with a percutaneous approach.

  11. Multidetector computed tomographic angiography of aberrant subclavian arteries.

    PubMed

    Türkvatan, Aysel; Büyükbayraktar, Fatma Gül; Olçer, Tülay; Cumhur, Turhan

    2009-02-01

    The purpose of this study was to evaluate the utility of 16-slice multidetector computed tomographic (MDCT) angiography for identifying anatomic features of aberrant subclavian arteries. Seventeen patients with aberrant subclavian arteries were assessed by MDCT angiography. The aortic arch position, the presence of a Kommerell's diverticulum, aneurysm, vascular compression of trachea and oesophagus and associated cardiovascular abnormalities were evaluated. MDCT findings were confirmed by surgery in eight patients but in the other nine patients no further evaluation or management was warranted as the aberrant subclavian artery had no significant clinical consequence. Eleven patients had an aberrant right subclavian artery arising from the left aortic arch and six patients had an aberrant left subclavian artery arising from the right aortic arch. Kommerell's diverticulum was identified in three patients with an aberrant right subclavian artery and in five patients with an aberrant left subclavian artery. In two patients it was aneurysmal. Oesophageal compression was detected in eight patients, and tracheal compression was identified in only one paediatric patient. An aberrant subclavian artery was associated with complex congenital heart disease in one patient, intracardiac defects in two patients, aortic coarctation in two patients, patent ductus arteriosus in two patients and an aberrant vertebral artery in one patient. In conclusion, MDCT angiography is superior to digital subtraction angiography for the assessment of aberrant subclavian arteries since digital subtraction angiography has only a poor ability to visualize adjacent structures completely and is invasive in nature. MDCT angiography or magnetic resonance angiography are the current standard in the initial evaluation of thoracic vascular anomalies.

  12. Multidetector-row computed tomography in the planning of abdominal perforator flaps.

    PubMed

    Masia, J; Clavero, J A; Larrañaga, J R; Alomar, X; Pons, G; Serret, P

    2006-01-01

    An accurate preoperative evaluation of the vascular anatomy of the abdominal wall is extremely valuable in improving the surgical strategy in abdominal perforator flaps. The multidetector-row computer tomography offers thin slice coverage of extended volumes with an extremely high spatial resolution. From October 2003 to December 2004, 66 female patients had breast reconstruction surgery in our department using the deep inferior epigastric artery perforator flap. Our multidetector-row computer tomography studies were performed using a 16-detector-row computer tomography scanner. The image assessment was carried out using the following protocol: we first identified the best three perforators from each side of the abdomen. Then we conducted a three-dimensional reconstruction of the abdomen by identifying exactly where the three best perforators emerged from the rectus abdominis fascia. We then transferred the data obtained from the image to the patient using a coordinate system. In addition, we also placed the dominant perforators in the patient by using a conventional hand-held Doppler. During the operation we compared intra-operative findings, Doppler results and computer tomography outcomes. Neither false positive nor false negative results were found in the computer tomography outcome. Multidetector-row computer tomography provides us with an easy method of interpreting the virtual anatomic dissection in three dimensions. It has high sensitivity and specificity and provides a good quality evaluation of the perforator vessels. This information allows reduction of operating time and safer performance of surgery. The multidetector-row computer tomography is a highly effective tool in the preoperative study of abdominal perforator flaps. PMID:16716952

  13. Multi-Detector Computed Tomography Angiography for Coronary Artery Disease

    PubMed Central

    2005-01-01

    Executive Summary Purpose Computed tomography (CT) scanning continues to be an important modality for the diagnosis of injury and disease, most notably for indications of the head and abdomen. (1) According to a recent report published by the Canadian Institutes of Health Information, (1) there were about 10.3 scanners per million people in Canada as of January 2004. Ontario had the fewest number of CT scanners per million compared to the other provinces (8 CT scanners per million). The wait time for CT in Ontario of 5 weeks approaches the Canadian median of 6 weeks. This health technology and policy appraisal systematically reviews the published literature on multidetector CT (MDCT) angiography as a diagnostic tool for the newest indication for CT, coronary artery disease (CAD), and will apply the results of the review to current health care practices in Ontario. This review does not evaluate MDCT to detect coronary calcification without contrast medium for CAD screening purposes. The Technology Compared with conventional CT scanning, MDCT can provide smaller pieces of information and can cover a larger area faster. (2) Advancing MDCT technology (8, 16, 32, 64 slice systems) is capable of producing more images in less time. For general CT scanning, this faster capability can reduce the time that patients must stay still during the procedure, thereby reducing potential movement artefact. However, the additional clinical utility of images obtained from faster scanners compared to the images obtained from conventional CT scanners for current CT indications (i.e., non-moving body parts) is not known. There are suggestions that the new fast scanners can reduce wait times for general CT. MDCT angiography that utilizes a contrast medium, has been proposed as a minimally invasive replacement to coronary angiography to detect coronary artery disease. MDCT may take between 15 to 45 minutes; coronary angiography may take up to 1 hour. Although 16-slice and 32-slice CT

  14. Multidetector computed tomography evaluation of cavernous haemangioma of the azygous vein.

    PubMed

    Das, Karuna Moy; Ahmed, Ali M; Aljubab, Abdulwahab; Alzoum, Mohammed A

    2013-08-01

    Giant cavernous haemangioma of azygous arch is extremely rare. We present the multidetector computed tomography (MDCT) features of a mediastinal cavernous haemangioma in an asymptomatic child detected in a follow-up examination. MDCT features with multiple venous lakes filling from the periphery, focal specks of calcification, low-density soft tissue mass along with tortuous varicose veins and large feeding veins from the abdomen are suggestive of cavernous haemangioma.

  15. Multi-detector computed tomography of an aortic dissection in a cat.

    PubMed

    Scollan, Katherine; Sisson, David

    2014-03-01

    Contrast enhanced, multi-detector computed tomography (MDCT) is a useful diagnostic imaging modality that has become increasingly available in veterinary medicine. Multi-planar and three-dimensional reconstructions allow accurate and comprehensive assessment of cardiac and vascular lesions with short image acquisition times. ECG-gated, contrast enhanced MDCT was used to assess the lesion extent and therapeutic options in a case of aortic dissection diagnosed in a hypertensive cat. PMID:24485986

  16. [Update on cardiac imaging techniques. Echocardiography, cardiac magnetic resonance and multidetector computed tomography].

    PubMed

    de Vinuesa, Pastora Gallego García; del Castillo, Sonia Velasco; Torres, Río Aguilar; Bardera, Juan C Paré

    2008-02-01

    This review of progress in cardiac imaging techniques summarizes the most significant development reported in the last year on different echocardiographic techniques and their application in a range of settings, from the treatment of heart failure to their use in intraoperative monitoring and guiding interventional procedures. Large sections are devoted to recent developments in three-dimensional imaging and, because of its clinical importance, to magnetic resonance imaging. Finally, there is a comprehensive update on the use of multidetector computed tomography in cardiology.

  17. Multidetector computed tomography evaluation of cavernous haemangioma of the azygous vein

    PubMed Central

    Das, Karuna Moy; Ahmed, Ali M.; Aljubab, Abdulwahab; Alzoum, Mohammed A.

    2013-01-01

    Giant cavernous haemangioma of azygous arch is extremely rare. We present the multidetector computed tomography (MDCT) features of a mediastinal cavernous haemangioma in an asymptomatic child detected in a follow-up examination. MDCT features with multiple venous lakes filling from the periphery, focal specks of calcification, low-density soft tissue mass along with tortuous varicose veins and large feeding veins from the abdomen are suggestive of cavernous haemangioma. PMID:23660735

  18. Evaluation of pulmonary sequestration with multidetector computed tomography angiography in a select cohort of patients: A retrospective study

    PubMed Central

    Long, Qihua; Zha, Yunfei; Yang, Zhigang

    2016-01-01

    OBJECTIVES: This study aimed to evaluate the role of multidetector computed tomography angiography in diagnosing patients with pulmonary sequestration. METHODS: We retrospectively analyzed the computed tomography studies and clinical materials of 43 patients who had undergone preoperative multidetector computed tomography angiography in our hospital and had pathologically proven pulmonary sequestration. Each examination of pulmonary sequestration was reviewed for type, location, parenchymal changes, arterial supply and venous drainage on two-dimensional and three-dimensional computed tomography images. RESULTS: Multidetector computed tomography successfully detected all pulmonary sequestrations in the 43 patients (100%). This included 40 patients (93.0%) with intralobar sequestration and 3 patients (7.0%) with extralobar sequestration. The locations of pulmonary sequestration were left lower lobe (28 cases, 70% of intralobar sequestrations), right lower lobe (12 cases, 30% of intralobar sequestrations) and costodiaphragmatic sulcus (3 cases). Cases of sequestered lung presented as mass lesions (37.2%), cystic lesions (32.6%), pneumonic lesions (16.3%), cavitary lesions (9.3%) and bronchiectasis (4.6%). The angioarchitecture of pulmonary sequestration, including feeding arteries from the thoracic aorta (86.1%), celiac truck (9.3%), abdominal aorta (2.3%) and left gastric artery (2.3%) and venous drainage into inferior pulmonary veins (86.0%) and the azygos vein system (14.0%), was visualized on multidetector computed tomography. Finally, the multidetector computed tomography angiography results of the sequestered lungs and angioarchitectures were surgically confirmed in all the patients. CONCLUSIONS: As a noninvasive modality, multidetector computed tomography angiography is helpful for making diagnostic decisions regarding pulmonary sequestration with high confidence and for visualizing the related parenchymal characteristics, arterial supply, and venous drainage

  19. Extraperitoneal Rupture of a Bladder Diverticulum and the Role of Multidetector Computed Tomography Cystography.

    PubMed

    Kodama, Koichi; Takase, Yasukazu; Saito, Katsuhiko

    2016-11-01

    Nontraumatic rupture of the bladder is less widely recognized than traumatic rupture, with a challenging early diagnosis due to high variability in clinical presentations. We report a case of extraperitoneal rupture of a bladder diverticulum in a patient with diabetes mellitus who presented with paralytic ileus. Despite conservative management, the patient developed sepsis requiring surgical treatment. Urinary tract infection and bladder outlet obstruction were considered to be potential mechanisms of the rupture. Multidetector computed tomography cystography should be used as the first-line modality when evaluating for a suspected bladder rupture, even in patients with nontraumatic bladder rupture. PMID:27656418

  20. Identification of Cardiac and Aortic Injuries in Trauma with Multi-detector Computed Tomography

    PubMed Central

    Shergill, Arvind K; Maraj, Tishan; Barszczyk, Mark S; Cheung, Helen; Singh, Navneet; Zavodni, Anna E

    2015-01-01

    Blunt and penetrating cardiovascular (CV) injuries are associated with a high morbidity and mortality. Rapid detection of these injuries in trauma is critical for patient survival. The advent of multi-detector computed tomography (MDCT) has led to increased detection of CV injuries during rapid comprehensive scanning of stabilized major trauma patients. MDCT has the ability to acquire images with a higher temporal and spatial resolution, as well as the capability to create multiplanar reformats. This pictorial review illustrates several common and life-threatening traumatic CV injuries from a regional trauma center. PMID:26430541

  1. Primary lung and large airway neoplasms in children: current imaging evaluation with multidetector computed tomography.

    PubMed

    Amini, Behrang; Huang, Steven Y; Tsai, Jason; Benveniste, Marcelo F; Robledo, Hector H; Lee, Edward Y

    2013-07-01

    Multidetector computed tomography (MDCT) offers an important noninvasive imaging modality for confirmation and further characterization of primary lung and large airway neoplasms encountered in pediatric patients. Children represent a unique challenge in imaging, not only because of unique patient factors (eg, inability to follow instructions, motion, need for sedation) but because of the technical factors that must be optimized to reduce radiation dose. This article reviews an MDCT imaging algorithm, up-to-date imaging techniques, and clinical applications of MDCT for evaluating benign and malignant primary neoplasms of lung and large airway in infants and children.

  2. Role of Multidetector Computed Tomography in the Diagnosis of Colorectal Perforations.

    PubMed

    Saturnino, Pietro Paolo; Pinto, Antonio; Liguori, Carlo; Ponticiello, Gianluca; Romano, Luigia

    2016-02-01

    Colonic perforations can be classified into perforations that occur at the site of a localized pathologic process and cecal perforations that occur secondary to distal colonic obstructions. Rectal perforations may result from foreign bodies inserted into the rectum; moreover, deep rectal biopsies, polypectomy, improper cleansing enema, or thermometer placement may also lead to rectal perforation. Correct identification of the cause and site of the perforation is crucial for appropriate management and surgical planning. Multidetector row computed tomography has a pivot role in planning the type of operative treatment, the prognosis, and in assessing those patients who have clinical symptoms of peritonitis but no radiographic signs of perforation.

  3. Multi-detector computed tomography imaging of large airway pathology: A pictorial review

    PubMed Central

    Jugpal, Tejeshwar Singh; Garg, Anju; Sethi, Gulshan Rai; Daga, Mradul Kumar; Kumar, Jyoti

    2015-01-01

    The tracheobronchial tree is a musculo-cartilagenous framework which acts as a conduit to aerate the lungs and consequently the entire body. A large spectrum of pathological conditions can involve the trachea and bronchial airways. These may be congenital anomalies, infections, post-intubation airway injuries, foreign body aspiration or neoplasms involving the airway. Appropriate management of airway disease requires an early and accurate diagnosis. In this pictorial essay review, we will comprehensively describe the various airway pathologies and their imaging findings by multi-detector computed tomography. PMID:26753061

  4. Congenital Anomalies of the Aortic Arch: Evaluation with the Use of Multidetector Computed Tomography

    PubMed Central

    Büyükbayraktar, Fatma Gül; Ölçer, Tülay; Cumhur, Turhan

    2009-01-01

    Congenital anomalies of the aortic arch have clinical importance, as the anomalies may be associated with vascular rings or other congenital cardiovascular diseases. Multidetector computed tomography (MDCT) angiography enables one to display the detailed anatomy of vascular structures and the spatial relationships with adjacent organs; this ability is the greatest advantage of the use of MDCT angiography in comparison to other imaging modalities in the evaluation of the congenital anomalies of the aortic arch. In this review article, we illustrate 16-slice MDCT angiography appearances of congenital anomalies of the aortic arch. PMID:19270864

  5. [Capabilities of Multidetector Computed Tomography in Assessment of Atherosclerosis of Coronary Arteries].

    PubMed

    Barysheva, N A; Merkulova, I N; Sharia, M A; Veselova, T N

    2015-01-01

    The prevalence of ischemic heart disease (IHD) as well as high mortality from its exacerbations led to an active search and study of diagnostic methods to predict the possible development of acute coronary events. At the moment, it is proved that the morphological properties of atherosclerotic plaque largely determine the course of IHD. Contemporary multidetector computed tomography (MDCT) is the only non-invasive method which allows to study the state of coronary arteries. In this review we have analyzed capabilities of MDCT in assessing the severity of stenosis and calcification in the coronary arteries, as well as the structure of atherosclerotic plaques, including signs of "instability".

  6. [Capabilities of Multidetector Computed Tomography in Assessment of Atherosclerosis of Coronary Arteries].

    PubMed

    Barysheva, N A; Merkulova, I N; Sharia, M A; Veselova, T N

    2015-01-01

    The prevalence of ischemic heart disease (IHD) as well as high mortality from its exacerbations led to an active search and study of diagnostic methods to predict the possible development of acute coronary events. At the moment, it is proved that the morphological properties of atherosclerotic plaque largely determine the course of IHD. Contemporary multidetector computed tomography (MDCT) is the only non-invasive method which allows to study the state of coronary arteries. In this review we have analyzed capabilities of MDCT in assessing the severity of stenosis and calcification in the coronary arteries, as well as the structure of atherosclerotic plaques, including signs of "instability". PMID:26502511

  7. Comparison between clinical indicators of transmembrane oxygenator thrombosis and multidetector computed tomographic analysis.

    PubMed

    Panigada, Mauro; L'Acqua, Camilla; Passamonti, Serena Maria; Mietto, Cristina; Protti, Alessandro; Riva, Roberto; Gattinoni, Luciano

    2015-04-01

    This study aims to assess whether multidetector computed tomography (MDCT) could accurately confirm the clinical suspicion of transmembrane oxygenator thrombosis (MOT) during extracorporeal membrane oxygenation (ECMO). Twenty-seven oxygenators were examined using MDCT at the end of patient treatment. Transmembrane oxygenator thrombosis was suspected in 15 of them according to the presence of at least 2 of the following clinical indicators: (1) increase in d-dimer, (2) decrease in platelet count, (3) decrease in oxygenator performance, and (4) presence of clots on the surface of the oxygenator. Transmembrane oxygenator thrombosis was confirmed by MDCT in 5 (33%) of them. Transmembrane oxygenator thrombosis was unexpectedly found in 5 (41%) of the remaining 12 oxygenators not suspected for MOT. Eight (80%) of these oxygenators had clots accounting for less than 1% of total volume. Clots were mainly detectable at the apical corner of the oxygenator, most likely due to greater blood stasis. We found a significant increase in d-dimer and in membrane oxygenator shunt and a decrease in platelet count from the start to the discontinuation of ECMO. Hemostatic abnormalities significantly reverted 48 hours after oxygenator removal, suggesting the role of ECMO in activation of the coagulation cascade. Multidetector computed tomographic scan could not accurately confirm the clinical suspicion of MOT.

  8. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations.

    PubMed

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  9. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations*

    PubMed Central

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. PMID:27403020

  10. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations.

    PubMed

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. PMID:27403020

  11. An Unusual Left Ventricular Outflow Pseudoaneurysm: Usefulness of Echocardiography and Multidetector Computed Tomography for Surgical Repair

    SciTech Connect

    Da Col, Uberto; Ramoni, Enrico Di Bella, Isidoro; Ragni, Temistocle

    2009-01-15

    Left ventricular outflow tract (LVOT) pseudoaneurysm is a rare but potentially lethal complication, mainly after aortic root endocarditis or surgery. Usually it originates from a dehiscence in the mitral-aortic intervalvular fibrosa and it arises posteriorly to the aortic root. Due to these anatomical features, its imaging assessment is challenging and surgical repair requires complex procedures. An unusual case of LVOT pseudoaneurysm is described. It was detected by transthoracic ecocardiography 7 months after aortic root replacement for acute endocarditis. Multidetector computed tomography (MDCT) confirmed the presence of a pouch located between the aortic root and the right atrium. Computed tomography also detected the origin of the pseudoaneurysm from the muscular interventricular septum of the LVOT, rather below the aortic valve plane. It was repaired with an extracardiac surgical approach, sparing the aortic root bioprosthesis previously implanted. The high-resolution three-dimensional details provided by the preoperative MDCT allowed us to plan a simple and effective surgical strategy.

  12. [Review of pre- and post-treatment multidetector computed tomography findings in abdominal aortic aneurysms].

    PubMed

    Casula, E; Lonjedo, E; Cerverón, M J; Ruiz, A; Gómez, J

    2014-01-01

    The increase in the frequency of abdominal aortic aneurysms (AAA) and the widely accepted use of endovascular aneurysm repair (EVAR) as a first-line treatment or as an alternative to conventional surgery make it necessary for radiologists to have thorough knowledge of the pre- and post-treatment findings. The high image quality provided by multidetector computed tomography (MDCT) enables CT angiography to play a fundamental role in the study of AAA and in planning treatment. The objective of this article is to review the cases of AAA in which CT angiography was the main imaging technique, so that radiologists will be able to detect the signs related to this disease, to diagnose it, to plan treatment, and to detect complications in the postoperative period. PMID:23489768

  13. Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography

    PubMed Central

    Özkadif, S; Eken, E; Beşoluk, K; Dayan, M. O.

    2015-01-01

    The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed models from high resolution MDCT images were analyzed statistically. Consequently, when biometric measurement values of corresponding bones of antebrachium were compared, it was revealed that there was no statistical significance within both sexes but there were statistically important differences between both sexes in some biometric measurements. It has been suggested that the results from the study can shed light on future studies on the skeletal system and can form a modern point of view to anatomical education. PMID:27175177

  14. Demonstration of normal and dilated testicular veins by multidetector computed tomography.

    PubMed

    Karcaaltincaba, Musturay

    2011-04-01

    Recent advances in multidetector computed tomography (MDCT) technology enabled better visualization of testicular (gonadal) vein using submillimeter slice thickness and three-dimensional images. Normally, the testicular vein measures 1-3 mm and drains into the inferior vena cava and left renal vein on the right and left sides, respectively. They can be seen in most patients during MDCT studies. Curved planar and volume-rendered images can be used to display testicular veins. We aim to demonstrate MDCT findings of normal testicular vein and its pathologies including varicocele, varices, the testicular vascular pedicle sign, and phlebolith. The testicular vein can be dilated owing to varicocele or portal hypertension and in patients with intraabdominal seminomas arising from undescended testis. The testicular vein can also cause ureteral compression at the crossing point. Understanding MDCT findings of the normal testicular vein and its various pathologies can allow a correct diagnosis, thereby avoiding further diagnostic tests. PMID:21519988

  15. [Review of pre- and post-treatment multidetector computed tomography findings in abdominal aortic aneurysms].

    PubMed

    Casula, E; Lonjedo, E; Cerverón, M J; Ruiz, A; Gómez, J

    2014-01-01

    The increase in the frequency of abdominal aortic aneurysms (AAA) and the widely accepted use of endovascular aneurysm repair (EVAR) as a first-line treatment or as an alternative to conventional surgery make it necessary for radiologists to have thorough knowledge of the pre- and post-treatment findings. The high image quality provided by multidetector computed tomography (MDCT) enables CT angiography to play a fundamental role in the study of AAA and in planning treatment. The objective of this article is to review the cases of AAA in which CT angiography was the main imaging technique, so that radiologists will be able to detect the signs related to this disease, to diagnose it, to plan treatment, and to detect complications in the postoperative period.

  16. Comparison of the Diagnostic Image Quality of the Canine Maxillary Dentoalveolar Structures Obtained by Cone Beam Computed Tomography and 64-Multidetector Row Computed Tomography.

    PubMed

    Soukup, Jason W; Drees, Randi; Koenig, Lisa J; Snyder, Christopher J; Hetzel, Scott; Miles, Chanda R; Schwarz, Tobias

    2015-01-01

    The objective of this blinded study was to validate the use of cone beam computed tomography (C) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methylmethacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxillary segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT. PMID:26415384

  17. Quadricuspid pulmonary valve in an adult patient identified by transthoracic echocardiography and multi-detector computed tomography.

    PubMed

    Jung, Soo-Yeon

    2015-01-01

    Quadricuspid pulmonary valve is a rare congenital heart disease. It is infrequently associated with significant clinical complications and tends to be clinically silent. Because of its benign nature, it has been diagnosed mainly post mortem. Its diagnosis by transthoracic echocardiography is very difficult because of the anatomical features. We describe a case of quadricuspid pulmonary valve diagnosed by transthoracic echocardiography and electrocardiography-gated multi-detector row computed tomography.

  18. Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor.

    PubMed

    Yoon, Woong; Lee, Min Young; Ryu, Jung Min; Moon, Yong Ju; Lee, Sang Hun; Park, Jae Hong; Yun, Seung Pil; Jang, Min Woo; Park, Sung Su; Han, Ho Jae

    2010-03-01

    Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.

  19. Evaluation of cardiovascular anomalies in patients with asymptomatic turner syndrome using multidetector computed tomography.

    PubMed

    Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin; Chung, Woo Yeong

    2013-08-01

    Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed.

  20. Abdominal crush injury in the Sichuan earthquake evaluated by multidetector computed tomography

    PubMed Central

    Chen, Tian-Wu; Yang, Zhi-Gang; Dong, Zhi-Hui; Shao, Heng; Chu, Zhi-Gang; Tang, Si-Shi

    2011-01-01

    AIM: To investigate the features of abdominal crush injuries resulting from an earthquake using multidetector computed tomography (MDCT). METHODS: Fifty-one survivors with abdominal crush injuries due to the 2008 Sichuan earthquake underwent emergency non-enhanced scans with 16-row MDCT. Data were reviewed focusing on anatomic regions including lumbar vertebrae, abdominal wall soft tissue, retroperitoneum and intraperitoneal space; and types of traumatic lesions. RESULTS: Fractures of lumbar vertebrae and abdominal wall soft tissue injuries were more common than retro- and intraperitoneal injuries (P < 0.05). With regard to the 49 lumbar vertebral fractures in 24 patients, these occurred predominantly in the transverse process (P < 0.05), and 66.67% of patients (16/24) had fractures of multiple vertebrae, predominantly two vertebrae in 62.5% of patients (10/16), mainly in L1-3 vertebrae in 81.63% of the vertebrae (40/49). Retroperitoneal injuries occurred more frequently than intraperitoneal injuries (P < 0.05), and renal and liver injuries were most often seen in the retroperitoneum and in the intraperitoneal space, respectively (all P < 0.05). CONCLUSION: Transverse process fractures in two vertebrae among L1-3 vertebrae, injury of abdominal wall soft tissue, and renal injury might be features of earthquake-related crush abdominal injury. PMID:21666819

  1. A Structural and Functional Assessment of the Lung via Multidetector-Row Computed Tomography

    PubMed Central

    Hoffman, Eric A.; Simon, Brett A.; McLennan, Geoffrey

    2006-01-01

    With advances in multidetector-row computed tomography (MDCT), it is now possible to image the lung in 10 s or less and accurately extract the lungs, lobes, and airway tree to the fifth- through seventh-generation bronchi and to regionally characterize lung density, texture, ventilation, and perfusion. These methods are now being used to phenotype the lung in health and disease and to gain insights into the etiology of pathologic processes. This article outlines the application of these methodologies with specific emphasis on chronic obstructive pulmonary disease. We demonstrate the use of our methods for assessing regional ventilation and perfusion and demonstrate early data that show, in a sheep model, a regionally intact hypoxic pulmonary vasoconstrictor (HPV) response with an apparent inhibition of HPV regionally in the presence of inflammation. We present the hypothesis that, in subjects with pulmonary emphysema, one major contributing factor leading to parenchymal destruction is the lack of a regional blunting of HPV when the regional hypoxia is related to regional inflammatory events (bronchiolitis or alveolar flooding). If maintaining adequate blood flow to inflamed lung regions is critical to the nondestructive resolution of inflammatory events, the pathologic condition whereby HPV is sustained in regions of inflammation would likely have its greatest effect in the lung apices where blood flow is already reduced in the upright body posture. PMID:16921136

  2. To assess vascular calcification in the patients of hypoparathyroidism using multidetector computed tomography scan

    PubMed Central

    Agarwal, Pooja; Prakash, Mahesh; Singhal, Manphool; Bhadada, Sanjay Kumar; Gupta, Yashdeep; Khandelwal, Niranjan

    2015-01-01

    Background: Our pilot data showed an increased intima media thickness in the patients with sporadic idiopathic hypoparathyroidism (SIH). Alteration in homeostasis of calcium, phosphate, and parathyroid hormone (PTH) may predispose to increase the risk of cardiovascular morbidity and mortality. The data on objective assessment of this increased risk is however lacking. Objective: To assess the effect of altered calcium, phosphate, and PTH homeostasis in the patients with SIH on coronary calcium score (a marker of increase vascular risk) by multidetector computed tomography scan (MDCT). Methods: In this case-control study, we measured coronary CT calcium score in 30 patients of SIH and compared with 40 age and sex matched healthy subjects. Correlation of coronary calcium score with biochemical parameters was evaluated. Results: Three of the 30 cases (10%) with SIH were found to have coronary artery calcification (CAC) of varying degree, whereas none of the control showed CAC (P = 0.07). The patients with CAC had significantly lower serum calcium levels (albumin corrected), as compared to the patients without CAC. Inverse correlation of CAC was found with serum calcium levels. No correlation was found with other biochemical parameters. Conclusion: The vascular risk is increased in the patients with SIH as assessed by coronary calcium score measured by MDCT. Low serum calcium levels might be a predisposing factor for this increased risk. PMID:26693429

  3. Evaluation of Cardiovascular Anomalies in Patients with Asymptomatic Turner Syndrome Using Multidetector Computed Tomography

    PubMed Central

    Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin

    2013-01-01

    Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed. PMID:23960443

  4. PULMONARY ANGIOGRAPHY WITH 64-MULTIDETECTOR-ROW COMPUTED TOMOGRAPHY IN NORMAL DOGS

    PubMed Central

    Drees, Randi; Frydrychowicz, Alex; Keuler, Nicholas S.; Reeder, Scott B.; Johnson, Rebecca

    2012-01-01

    Pulmonary angiography using 64-multidetector-row computed tomography (MDCT) was used to evaluate pulmonary artery anatomy, and determine the sensitivity of pulmonary artery segment visualization in four Beagle dogs using images reconstructed to 0.625 mm and retro-reconstructed to 1.25 and 2.5 mm slice thickness. Morphologically, characteristic features included a focal narrowing in the right cranial pulmonary artery in all dogs, which should not be mistaken as stenosis. While the right cranial pulmonary artery divided into two equally sized branches that were tracked into the periphery of the lung lobe in all dogs, only a single left cranial (cranial portion) lobar artery was present. Compared with 1.25 and 2.5 mm retro-reconstructions, 0.625 mm reconstructions allowed for detection of significantly (P ≤ 0.05) more pulmonary artery segments and sharper depiction of vessel margins. Clinical applications such as prevalence and significance of diameter changes, and detection of pulmonary arterial thrombembolism on lobar and sublobar level, using pulmonary angiography with 64-MDCT applying 0.625 mm reconstruction slice thickness remain to be established. PMID:21545367

  5. Multidetector Computed Tomography Features in Differentiating Exophytic Renal Angiomyolipoma from Retroperitoneal Liposarcoma

    PubMed Central

    Wang, Qiushi; Juan, Yu-Hsiang; Li, Yong; Xie, Jia-Jun; Liu, Hui; Huang, Hongfei; Liu, Zaiyi; Zheng, Junhui; Saboo, Ujwala S.; Saboo, Sachin S.; Liang, Changhong

    2015-01-01

    Abstract This study aims to evaluate the multidetector computed tomography (CT) imaging features in differentiating exophytic renal angiomyolipoma (AML) from retroperitoneal liposarcoma. We retrospectively enrolled 42 patients with confirmed exophytic renal AML (31 patients) or retroperitoneal liposarcoma (11 patients) during 8 years period to assess: renal parenchymal defect at site of tumor contact, supply from branches of renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, hemorrhage, non–fat-containing intratumoral nodules with postcontrast enhancement, calcification, renal sinus enlargement, anterior displacement of kidneys, and other associated AML. Renal parenchymal defect, renal arterial blood supply, tumoral vessel through the renal parenchyma, dilated intratumoral vessels, intratumoral/perirenal hemorrhage, renal sinus enlargement, and associated AML were seen only or mainly in exophytic renal AML (all P value < 0.05); however, non–fat-attenuating enhancing intratumoral nodules, intratumoral calcification, and anterior displacement of the kidney were more common in liposarcoma (all P value < 0.05). AMLs reveal renal parenchymal defect at the site of tumor contact, supply from renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, intratumoral and/or perirenal hemorrhage, renal sinus enlargement, and associated AML. Non–fat-attenuating enhancing intratumoral nodules, intratumoral calcifications, and anterior displacement of kidney were more commonly seen in liposarcoma. PMID:26376398

  6. Stature estimation in Japanese cadavers using the sacral and coccygeal length measured with multidetector computed tomography.

    PubMed

    Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Ishii, Namiko; Hayakawa, Mutsumi; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Iwase, Hirotaro

    2014-01-01

    We evaluated the relationship between stature and the length of the sacrum and coccyx using multidetector computed tomography (MDCT) and derived regression equations for stature estimation in the modern Japanese population. Two hundred and sixteen Japanese subjects (110 males and 106 females) who underwent postmortem computed tomography with subsequent forensic autopsy between January 2010 and August 2013 were measured. A sagittal-plane image of the sacrum and coccyx was used. Anterior sacral length (ASL) was defined as the linear distance from the anterosuperior edge of the first sacral vertebra (S1) to the anteroinferior edge of the fifth sacral vertebra (S5), and posterior sacral length (PSL) was defined as the linear distance from the posterosuperior edge of S1 to the anteroinferior edge of S5. Anterior sacrococcygeal length (ASCL) was defined as the linear distance from the anterosuperior edge of S1 to the anteroinferior edge of the last coccygeal vertebra (LCV), and posterior sacrococcygeal length (PSCL) was defined as the linear distance from the posterosuperior edge of S1 to the anteroinferior edge of the LCV. The correlation between stature and each parameter was evaluated by simple regression analysis using Pearson product-moment correlation coefficients. Each parameter was significantly and positively correlated with stature among both males and females. Cadaver stature (CS, cm)=0.39×PSL (mm)+123.70 [Corrected] provided the most accurate stature prediction (R=0.507, SEE=5.83 cm) in males. CS (cm)=0.56×PSCL (mm)+85.29 provided the most accurate stature prediction (R=0.659, SEE=6.68 cm) in females. We conclude that sacral/sacrococcygeal length measured with MDCT is a potentially useful tool for stature estimation, particularly in cases where better predictors such as the long bones are not available.

  7. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants *

    PubMed Central

    Araujo Neto, Severino Aires; de Mello Júnior, Carlos Fernando; Franca, Henrique Almeida; Duarte, Cláudia Martina Araújo; Borges, Rafael Farias; de Magalhães, Ana Guardiana Ximenes

    2016-01-01

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. PMID:26929461

  8. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants.

    PubMed

    Araujo Neto, Severino Aires; de Mello Júnior, Carlos Fernando; Franca, Henrique Almeida; Duarte, Cláudia Martina Araújo; Borges, Rafael Farias; de Magalhães, Ana Guardiana Ximenes

    2016-01-01

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications.

  9. Multi-Detector Computed Tomography in Evaluating Locally Aggressive and Malignant Bone Tumours

    PubMed Central

    Ramavathu, Kumar Venu Madhav; Garga, U.C.

    2015-01-01

    Objective: To evaluate the ability of Multi-Detector Computed Tomography in preoperative evaluation of locally aggressive and malignant bone tumours in correlation with histopathological findings. Materials and Methods: Twenty patients suspected of malignant bone tumours on the basis of their clinical profile were selected. Following a plain radiograph evaluation, all of them were subjected to CT scan examination. Multi Planar Reconstruction (MPR) was done in sagittal and coronal planes and also three-dimensional Volume Rendering (VR) and Maximum Intensity Projection (MIP) images were obtained. Results: Of the 20 patients, 18 underwent surgery, and their histopathological findings were compared and correlated with MDCT findings. MDCT was 92.8% sensitive and 100% specific in determining the vascularity of the tumour and also can detect displacement/ encasement/ involvement of adjacent vessels. It has a sensitivity and specificity of 100% in determining cortical break, calcification and periosteal reaction. However, it is less sensitive in detecting joint involvement. Post contrast enhancement gives details of the extent of the soft tissue component. Conclusion: Although MRI is a preferred modality in preoperative evaluation of bone tumours, CT may be used an alternative in case of non-availability of MRI, which has faster acquisition time and better resolution. Using three dimensional MPR imaging, the location and extent of the tumour can be studied. It is also useful in determining cortical discontinuity, periosteal reaction, and calcification. By virtue of MIP and VR imaging, vascularity of the tumour and its relationship with the adjacent vasculature can be established. However, it is inferior to MRI in soft tissue characterization and has poor sensitivity in detecting marrow and joint involvement. PMID:26023618

  10. Airway Evaluation with Multidetector Computed Tomography Post-Processing Methods in Asthmatic Patients.

    PubMed

    Patyk, Mateusz; Obojski, Andrzej; Gojny, Łukasz; Panaszek, Bernard; Zaleska-Dorobisz, Urszula

    2016-01-01

    Asthma is a chronic inflammatory obstructive airways disease. The disease occurs regardless of age and manifests with cough, attacks of breathlessness, and tightness in the chest. The pathophysiology of asthma is complex and still not fully understood. It is essential to find answers concerning the role of each part of the bronchial tree in asthma, especially the role of small bronchioles. With the development of newer generations of multidetector computed tomography (MDCT) and advanced post-processing methods it is possible to obtain more detailed images and gain insight into further aspects of asthma. MDCT post-processing methods can be divided into two-dimensional (2D) and three-dimensional (3D). In 2D projections, visualized hypodense regions correspond to the airway flow limitations. With the more advanced methods, such as multi planar reconstructions (MPR), images in different planes (axial, coronal, or sagittal) can be created. In the MPR technique only the voxels which are adjacent to each other in the predetermined plane can be extracted from the data set. Using the minimal/maximal intensity projections and shaded surface display, the volume of interest (VOI) can be extracted. High resolution CT scans can be used to create a more advanced imaging tool - the virtual bronchoscopy (VB). Using the VB makes it possible to visualize regions of obturation in the bronchi of up to the 5-8th generation. The MDCT with advanced post-processing methods is likely to assume an important role in the differential diagnosis of asthma, particularly when the diagnosis is dubious or hard to settle due to accompanying other lung diseases. PMID:27271759

  11. Anthropometric Assessment of Neck Adipose Tissue and Airway Volume Using Multidetector Computed Tomography

    PubMed Central

    Maresky, Hillel S.; Sharfman, Zachary; Ziv-Baran, Tomer; Gomori, J.M.; Copel, Laurian; Tal, Sigal

    2015-01-01

    Abstract Neck adiposity tissue volume (NATV) accumulation is an indicator for metabolic syndrome and cardiovascular disease (CVD). Neck circumference is a poor measure of NATV, and a quantifier for this entity has not yet been established. To evaluate volumetric quantification by multidetector computed tomography (MDCT) as a reproducible anthropometric tool to measure NATV and airway volume (AWV). A total of 519 patients, including a subset of 70 random patients who underwent head and neck CT scanning in our hospital within 1 year (2013), were studied. Included patients were all those undergoing nonenhanced CT (NECT) or CT angiography (CTA). Neck cross-sectional areas (NCSA) were measured at 2 separate levels of the neck, and 3D postprocessing tissue reconstruction was performed, and NATV and AWVs were quantified volumetrically for all patients within the year. The average NCSA at the level of the soft palate and thyroid cartilage was 22,579 and 14,500 mm2, respectively. NATV when compared to the upper and lower levels of NCSA showed correlations of 0.64 and 0.79, respectively (P < 0.001). Interobserver analysis showed mean deviations of 0.46% and 0.32% for NATV and AWV, respectively. A strong correlation between NATV and body mass index (BMI) was found (r = 0.658, P < 0.001), and the top quartile of NATV:AWV patients (out of 519 patients) displayed a statistically significant mortality rate during 670 days of follow-up (d = 7.5%, P = 0.032). After adjustment for age and gender, the association between NATV:AWV and mortality was close to significant (P = 0.072). Volumetric quantification of NATV and AWV is a reproducible and prognostic anthropometric tool, as a high NATV:AWV demonstrated a significant risk factor for mortality; future research may further advance our understanding of this phenomenon. PMID:26559286

  12. Tendon entrapments and dislocations in ankle and hindfoot fractures: evaluation with multidetector computed tomography.

    PubMed

    Ballard, David H; Campbell, Kevin J; Blanton, Lee E; Williams, Jason T; Sangster, Guillermo; Hollister, Anne M; Simoncini, Alberto A

    2016-08-01

    The purpose of this study was to assess the incidence of tendon entrapments and tendon dislocations associated with ankle and hindfoot fractures in patients studied by multidetector computed tomography (MDCT). Additionally, we describe particular tendon injuries associated with specific fractures. This was a retrospective review of all individuals with a trauma-protocol CT for suspected ankle and/or hindfoot fractures during a consecutive 41-month time period at a single Level I Trauma Center. Each patient's images were evaluated by two radiologists and an orthopedic surgeon for tendon entrapment, tendon dislocation, and bone(s) fractured or dislocated. There were 398 patients with ankle and/or hindfoot fractures that showed tendon entrapment or dislocation in 64 (16.1 %) patients. There were 30 (46.9 %) patients with 40 tendon entrapments, 31 (48.4 %) patients with 59 tendon dislocations, and three (4.7 %) patients with both tendon entrapment and dislocation. All patients with tendon entrapments were seen with either pilon fractures and/or a combination of posterior, medial, or lateral malleolar fractures. The most frequently entrapped tendon was the posterior tibialis tendon (PTT) in 27 patients (27/30, 90.0 %). The peroneal tendons were the most frequently dislocated, representing 27 (87.1 %) of patients with tendon dislocation; all resulted from a talar or calcaneal fracture or subluxation. This study demonstrates that tendon entrapments and tendon dislocations are commonly seen in complex fractures of the ankle and hindfoot. Pilon fractures were associated with the majority of tendon entrapments, whereas calcaneus fractures were associated with the majority of tendon dislocations. PMID:27234977

  13. A case of fatal sigmoid volvulus visualized on postmortem radiography: The importance of image optimization with multidetector computed tomography.

    PubMed

    Usui, Akihito; Kawasumi, Yusuke; Hosokai, Yoshiyuki; Ishizuka, Yuya; Ikeda, Tomoya; Saito, Haruo; Funayama, Masato

    2016-03-01

    This report describes the case of a man who developed fatal sigmoid volvulus that was identified on postmortem radiography before forensic autopsy. Postmortem radiography is useful for visualizing the body prior to autopsy. We discuss postmortem multidetector computed tomography that was tailored for optimum image quality to allow reconstruction of the fatal findings in multiple axes and in three dimensions, helping to pinpoint the anatomical sites of interest. This involves techniques such as manipulation of the scanning beam pitch and overlapping CT section acquisition. These techniques are best performed by personnel with CT technology training. PMID:26980251

  14. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    PubMed Central

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images

  15. The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations

    SciTech Connect

    Tzedakis, A.; Damilakis, J.; Perisinakis, K.; Stratakis, J.; Gourtsoyiannis, N.

    2005-06-15

    z overscanning in multidetector (MD) helical CT scanning is prerequisite for the interpolation of acquired data required during image reconstruction and refers to the exposure of tissues beyond the boundaries of the volume to be imaged. The aim of the present study was to evaluate the effect of z overscanning on the patient effective dose from helical MD CT examinations. The Monte Carlo N-particle radiation transport code was employed in the current study to simulate CT exposure. The validity of the Monte Carlo simulation was verified by (a) a comparison of calculated and measured standard computed tomography dose index (CTDI) dosimetric data, and (b) a comparison of calculated and measured dose profiles along the z axis. CTDI was measured using a pencil ionization chamber and head and body CT phantoms. Dose profiles along the z axis were obtained using thermoluminescence dosimeters. A commercially available mathematical anthropomorphic phantom was used for the estimation of effective doses from four standard CT examinations, i.e., head and neck, chest, abdomen and pelvis, and trunk studies. Data for both axial and helical modes of operation were obtained. In the helical mode, z overscanning was taken into account. The calculated effective dose from a CT exposure was normalized to CTDI{sub freeinair}. The percentage differences in the normalized effective dose between contiguous axial and helical scans with pitch=1, may reach 13.1%, 35.8%, 29.0%, and 21.5%, for head and neck, chest, abdomen and pelvis, and trunk studies, respectively. Given that the same kilovoltage and tube load per rotation were used in both axial and helical scans, the above differences may be attributed to z overscanning. For helical scans with pitch=1, broader beam collimation is associated with increased z overscanning and consequently higher normalized effective dose value, when other scanning parameters are held constant. For a given beam collimation, the selection of a higher value of

  16. Quantitative Analysis of Intraventricular Dyssynchrony Using Wall Thickness by Multidetector Computed Tomography

    PubMed Central

    Truong, Quynh A.; Singh, Jagmeet P.; Cannon, Christopher P.; Sarwar, Ammar; Nasir, Khurram; Auricchio, Angelo; Faletra, Francesco F.; Sorgente, Antonio; Conca, Cristina; Moccetti, Tiziano; Handschumacher, Mark; Brady, Thomas J.; Hoffmann, Udo

    2009-01-01

    OBJECTIVES We sought to determine the feasibility of cardiac computed tomography (CT) to detect significant differences in the extent of left ventricular dyssynchrony in heart failure (HF) patients with wide QRS, HF patients with narrow QRS, and age-matched controls. BACKGROUND The degree of mechanical dyssynchrony has been suggested as a predictor of response to cardiac resynchronization therapy. There have been no published reports of dyssynchrony assessment with the use of CT. METHODS Thirty-eight subjects underwent electrocardiogram-gated contrast-enhanced 64-slice multidetector CT. The left ventricular endocardial and epicardial boundaries were delineated from short-axis images reconstructed at 10% phase increments of the cardiac cycle. Global and segmental CT dyssynchrony metrics that used changes in wall thickness, wall motion, and volume over time were assessed for reproducibility. We defined a global metric using changes in wall thickness as the dyssynchrony index (DI). RESULTS The DI was the most reproducible metric (interobserver and intraobserver intraclass correlation coefficients ≥0.94, p < 0.0001) and was used to determine differences between the 3 groups: HF-wide QRS group (ejection fraction [EF] 22 ± 8%, QRS 163 ± 28 ms), HF-narrow QRS (EF 26 ± 7%, QRS 96 ± 11 ms), and age-matched control subjects (EF 64 ± 5%, QRS 87 ± 9 ms). Mean DI was significantly different between the 3 groups (HF-wide QRS: 152 ± 44 ms, HF-narrow QRS: 121 ± 58 ms, and control subjects: 65 ± 12 ms; p < 0.0001) and greater in the HF-wide QRS (p < 0.0001) and HF-narrow QRS (p = 0.005) groups compared with control subjects. We found that DI had a good correlation with 2-dimensional (r = 0.65, p = 0.012) and 3-dimensional (r = 0.68, p = 0.008) echocardiographic dyssynchrony. CONCLUSIONS Quantitative assessment of global CT-derived DI, based on changes in wall thickness over time, is highly reproducible and renders significant differences between subjects most likely to

  17. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    PubMed

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%. PMID:25675779

  18. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    PubMed

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.

  19. Validation of a paediatric thyroid phantom using different multidetector computed tomography models

    NASA Astrophysics Data System (ADS)

    Alsabbagh, M.; Ng, L. Y.; Tajuddin, A. A.; Manap, M. A.; Zainon, R.

    2016-03-01

    The aim of this study was to compare the attenuation values of a fabricated paediatric thyroid phantom material using different MDCT models. A paediatric thyroid phantom was designed to mimic the shape and size of a paediatric patient with an age of 9 years using high- density Polyethylene as the phantom material. The fabricated phantom was scanned using two different multidetector CT scanners (16- and 128-row detectors). The CT numbers were evaluated and the mass attenuation coefficients (μ/ρ) of the phantom material were obtained at each applied energy from each scanner. The results were compared with the tables of the National Institute of Standards and Technology (NIST). The CTs of 16- and 128-row detectors showed that the obtained attenuation values are very similar to the NIST's values. However, the CT of the 128-row detectors showed a slightly much closer match to the NIST's values. This refers to the type and quality of the electronic connections between the detectors. Furthermore, the type and number of detectors (16- and 128-detectors) could affect the details and quality of the output images. The results show that different multidetector CTs can be used to validate the phantom and determine the mass attenuation coefficients of its material.

  20. Observational case series: an algorithm incorporating multidetector computed tomography in the medicolegal investigation of human remains after a natural disaster.

    PubMed

    Berran, Philip J; Mazuchowski, Edward L; Marzouk, Abubakr; Harcke, H Theodore

    2014-07-01

    An algorithm incorporating multidetector computed tomography (MDCT), digital radiographs, and external examination was used to triage cases for noninvasive or complete autopsy after a natural disaster. The algorithm was applied to 27 individuals who died during or soon after the earthquake that struck the Republic of Haiti on January 12, 2010. Of the 27 cases reviewed, 7 (26%) required a complete autopsy to determine cause and manner of death. In the remaining 20 (74%), cause and manner of death were determined with a reasonable degree of medical certainty after review of circumstances, an external examination, and postmortem imaging by MDCT and digital radiography (noninvasive autopsy). MDCT was particularly useful in detecting skeletal fractures caused by blunt force injury which were not evident on digital radiographs. The algorithm incorporating postmortem MDCT can be useful in the triage of human remains for autopsy after a natural disaster.

  1. Stature estimation based on measurements of the sternal medullary cavity using multidetector computed tomography images of Japanese cadavers.

    PubMed

    Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Hayakawa, Mutsumi; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Iwase, Hirotaro

    2014-09-01

    Stature estimation using a skeleton is important for the medicolegal investigation of unidentified human remains. The aims of this study were to identify a correlation between stature and measurements of the sternal medullary cavity using multidetector computed tomography (MDCT) and derive regression equations for stature estimation in the Japanese population. Measurements were conducted on 215 Japanese subjects (107 males, 108 females) who underwent postmortem computed tomography with subsequent forensic autopsy between May 2012 and January 2014. For assessment, MDCT cross-sections through the mid-point of the first costal facets were chosen. The length of a rising diagonal stroke from the bottom left to the top right of the sternal medullary cavity (RS) and the length of a falling diagonal stroke from top left to bottom right of the sternal medullary cavity (FS) were measured. Statistical analyses indicated that both RS and FS were positively correlated with stature regardless of sex. The correlations were stronger for males than for females. The correlation coefficients for RS were higher than those for FS, and standard errors of estimation calculated by regression analysis using RS were lower than those using FS regardless of sex. Measurement of the sternal medullary cavity using MDCT images may be a potentially useful tool for stature estimation, particularly in cases where better predictors such as long bones are not available. PMID:25082372

  2. Quantification of global left ventricular function: comparison of multidetector computed tomography and magnetic resonance imaging. a meta-analysis and review of the current literature.

    PubMed

    van der Vleuten, P A; Willems, T P; Götte, M J W; Tio, R A; Greuter, M J W; Zijlstra, F; Oudkerk, M

    2006-12-01

    Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI.

  3. Thoracic Injuries in earthquake-related versus non-earthquake-related trauma patients: differentiation via Multi-detector Computed Tomography

    PubMed Central

    Dong, Zhi-hui; Yang, Zhi-gang; Chen, Tian-wu; Chu, Zhi-gang; Deng, Wen; Shao, Heng

    2011-01-01

    PURPOSE: Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). METHODS: We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. RESULTS: The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; p<0.001). Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR = 1.2; p<0.05) or flail chest (45/143 vs. 11/66 patients, RR = 1.9; p<0.05) were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR = 1.7; p<0.01). Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR = 1.4; p<0.01). Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR = 1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001). Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. CONCLUSIONS: Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries. PMID:21789386

  4. Evaluation of lower-limb arteries with multidetector computed tomography angiography prior to free flap surgery: a radioanatomic study.

    PubMed

    Tan, Onder; Yuce, Ihsan; Kantarci, Mecit; Algan, Said

    2011-03-01

    In this study, we aimed to evaluate the vascular structures of the lower limb with multidetector computed tomography (CT) angiography and to reveal the importance of this method in preoperative planning of microsurgical transplantation. In 24 patients, lower-limb arteries were bilaterally evaluated with 16-detector spiral CT scanner in terms of patency, stenosis, or occlusion; maximal and minimal external diameters through their traces; and variations as well as length of the peroneal artery. The peroneal artery was absent unilaterally in two patients (4.3%). The mean maximal and minimal diameters were as 2.77 and 1.63, 2.92 and 1.75, and 2.72 and 1.50 mm for anterior and posterior tibial and peroneal arteries, respectively. The ranges of lengths of peroneal arteries were 50 to 117 mm. This valuable tool can provide detailed information about vascular and the remaining anatomic structures by means of its high-resolution characteristics before planning free flap surgery. PMID:21181625

  5. Preoperative evaluation value of aortic arch lesions by multidetector computed tomography angiography in type A aortic dissection.

    PubMed

    Huang, Fang; Chen, Qiang; Lai, Qing-Quan; Huang, Wen-Han; Wu, Hong; Li, Wei-Cheng

    2016-09-01

    The purpose of this study was to preoperatively evaluate the value of aortic arch lesions by multidetector computed tomography (MDCT) angiography in type A aortic dissection (AD).From January 2013 to December 2015, we enrolled 42 patients with type A AD who underwent MDCT angiography in our hospital. The institutional database of patients was retrospectively reviewed to identify MDCT angiography examinations for type A AD. Surgical corrections were conducted in all patients to confirm diagnostic accuracy.In this study, the diagnostic accuracy of MDCT angiography was 100% in all 42 patients. The intimal tear site locations that were identified in patients included the ascending aorta (n = 25), aortic arch (n = 12), and all other sites (n = 5). Compared with the control group, there were significant differences in the aortic arch anatomy among the cases. Regarding the distance between the left common carotid and left subclavian arteries, compared with the control group, most cases with type A AD had a significant variation.MDCT angiography plays an important role in detecting aortic arch lesions of type A AD, especially in determining the location of the intimal entry site and change of branch blood vessels. Surgeons can formulate an appropriate operating plan, according to the preoperative MDCT diagnosis information. PMID:27684852

  6. Split-Bolus Multidetector-Row Computed Tomography Technique for Characterization of Focal Liver Lesions in Oncologic Patients

    PubMed Central

    Scialpi, Michele; Pierotti, Luisa; Gravante, Sabrina; Rebonato, Alberto; Piscioli, Irene; D’Andrea, Alfredo; Schiavone, Raffaele; Palumbo, Barbara

    2016-01-01

    Background In oncologic patients, the liver is the most common target for metastases. An accurate detection and characterization of focal liver lesions in patients with known primary extrahepatic malignancy are essential to define management and prognosis. Objectives To assess the diagnostic accuracy of the split-bolus multidetector-row computed tomography (MDCT) protocol in the characterization of focal liver lesions in oncologic patients. Patients and Methods We retrospectively analyzed the follow-up split-bolus 64-detector row CT protocol in 36 oncologic patients to characterize focal liver lesions. The split-bolus MDCT protocol by intravenous injection of two boluses of contrast medium combines the hepatic arterial phase (HAP) and hepatic enhancement during the portal venous phase (PVP) in a single-pass. Results The split-bolus MDCT protocol detected 208 lesions and characterized 186 (89.4%) of them: typical hemangiomas (n = 9), atypical hemangiomas (n = 3), cysts (n = 78), hypovascular (n = 93) and hypervascular (n = 3) metastases. Twenty two (10.6%) hypodense lesions were categorized as indeterminate (≤5 mm). The mean radiation dose was 24.5±6.5 millisieverts (mSv). Conclusion The designed split-bolus MDCT technique can be proposed alternatively to triphasic MDCT and in a single-pass to PVP in the initial staging and in the follow-up respectively in oncologic patients.

  7. Three-dimensional reconstruction of medieval child mummy in Yangju, Korea, using multi-detector computed tomography.

    PubMed

    Lee, In Sun; Kim, Myeung Ju; Yoo, Dong Soo; Lee, Young Seok; Park, Sung Sil; Bok, Gi Dae; Han, Seung Ho; Chung, Yoon Hee; Chang, Byung Soo; Yi, Yang Su; Oh, Chang Seok; Shin, Dong Hoon

    2007-01-01

    Recently reported studies on the medieval mummies in Korea have been regarded as an invaluable source for studying the physical characteristics of medieval Koreans. However, since the reported medieval mummies were re-buried by their descendants without any scientific investigations, the development of a brief, non-invasive investigation technique was desperately needed among the researchers in Korea. In this regard, we tried to apply high-quality multi-detector computed tomography (MDCT) with three-dimensional (3D) reconstructions and multi-planar reformat (MPR) to investigate Korean mummies. In our study, after 1.25 or 2.5mm thin slice axial images were taken, 3D reconstruction and MPR were performed to get more accurate information about internal organs. In this trial, we successfully showed high-quality images for the brain, muscles, bones, heart and liver. During various trials for getting selected organs, we could make the 3D reconstructed images of them. Since we could show that the current MDCT technique could be useful for obtaining high-quality 3D reconstructed images of the internal organs of Korean mummies, this technique will be used in forthcoming similar cases, which could not be investigated using invasive techniques.

  8. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography*

    PubMed Central

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; de Mello Júnior, Carlos Fernando; Silva Neto, Eulâmpio José; Negromonte, Gustavo Ramalho Pessoa; Duarte, Cláudia Martina Araújo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca

    2015-01-01

    Objective To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials and Methods Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. PMID:26811552

  9. MULTIDETECTOR-ROW COMPUTED TOMOGRAPHY PATTERNS OF BRONCHOESPHAGEAL ARTERY HYPERTROPHY AND SYSTEMIC-TO-PULMONARY FISTULA IN DOGS.

    PubMed

    Ledda, Gianluca; Caldin, Marco; Mezzalira, Giorgia; Bertolini, Giovanna

    2015-01-01

    Anomalies involving arterial branches in the lungs are one of the causes of hemoptysis in humans and dogs. Congenital and acquired patterns of bronchoesophageal artery hypertrophy have been reported in humans based on CT characteristics. The purpose of this retrospective study was to describe clinical, echocardiographic, and multidetector computed tomography features of bronchoesophageal artery hypertrophy and systemic-to-pulmonary arterial communications in a sample of 14 dogs. Two main vascular patterns were identified in dogs that resembled congenital and acquired conditions reported in humans. Pattern 1 appeared as an aberrant origin of the right bronchoesophageal artery, normal origin of the left one, and enlargement of both the bronchial and esophageal branches that formed a dense network terminating in a pulmonary artery through an orifice. Pattern 2 appeared as a normal origin of both right and left bronchoesophageal arteries, with an enlarged and tortuous course along the bronchi to the periphery of the lung, where they communicated with subsegmental pulmonary arteries. Dogs having Pattern 1 also had paraesophageal and esophageal varices, with the latter being confirmed by videoendoscopy examination. Authors conclude that dogs with Pattern 1 should be differentiated from dogs with other congenital vascular systemic-to-pulmonary connections. Dogs having Pattern 2 should be evaluated for underlying pleural or pulmonary diseases. Bronchoesophageal artery hypertrophy can be accompanied by esophageal venous engorgement and should be included in the differential diagnosis for esophageal and paraesophageal varices in dogs. PMID:25961802

  10. [Study of anatomy of the lateral attachment of the renal fascia in adult with multidetector computed tomography].

    PubMed

    Qi, Rui; Zhou, Xianping; Yu, Jianqun; Chen, Weixia; Li, Zhenlin; Zhang, Chunle

    2012-08-01

    The present paper is aimed to observe the lateral attachment of the renal fascia (RF) in vivo with multidetector computed tomography (MDCT) scanning, and to discuss its diagnostic value. 121 healthy adults were adopted into this experiment. All images were obtained with MDCT and double phase enhancement scanning. Then we observed the lateral attachment of RF. In addition, we mad a fresh body specimen as anatomical basis. The study found that above the renal hilar plane (RHP), the anterior renal fascia laterally fused with the peritoneum of the liver on the right and the peritoneum of the spleen on the left,and the posterior renal fascia fused with the subdiaphragmatic fascia. The lateral attachment of the RF at the RHP and the lower renal pole(LRP)is divided into three types. The RF in Type I is about 47.9% (58/121) at the left RHP, while about 33.9% (41/121) at the right RHP. At the LRP of the kidney is about 55.3% (67/121) on the left, and about 42.1% (51/121) on the right. The RF in Type I is about 38.8% (47/121) on the left side at the RHP, about 26.4% (32/121) on the right side. At the LRP, left side about 27.3% (33/121), right side about 13.3%(16/121). The RF in Type III at the RHP is 13.3% (16/121) on the left side, and on the right side is about 39.7% (48/121). At the LRP, it is about 17.4% (21/121) on the left side, and about 44.6% (54/121) on the right side. MDCT can display the lateral attachment of the RF better as well as the outside connection of the retroperitoneal space.

  11. Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance

    PubMed Central

    Vanhoenacker, Piet K; Decramer, Isabel; Bladt, Olivier; Sarno, Giovanna; Van Hul, Erik; Wijns, William; Dwamena, Ben A

    2008-01-01

    Background Multi-detector computed tomography angiography (MDCTA)of the coronary arteries after stenting has been evaluated in multiple studies. The purpose of this study was to perform a structured review and meta-analysis of the diagnostic performance of MDCTA for the detection of in-stent restenosis in the coronary arteries. Methods A Pubmed and manual search of the literature on in-stent restenosis (ISR) detected on MDCTA compared with conventional coronary angiography (CA) was performed. Bivariate summary receiver operating curve (SROC) analysis, with calculation of summary estimates was done on a stent and patient basis. In addition, the influence of study characteristics on diagnostic performance and number of non-assessable segments (NAP) was investigated with logistic meta-regression. Results Fourteen studies were included. On a stent basis, Pooled sensitivity and specificity were 0.82(0.72–0.89) and 0.91 (0.83–0.96). Pooled negative likelihood ratio and positive likelihood ratio were 0.20 (0.13–0.32) and 9.34 (4.68–18.62) respectively. The exclusion of non-assessable stents and the strut thickness of the stents had an influence on the diagnostic performance. The proportion of non-assessable stents was influenced by the number of detectors, stent diameter, strut thickness and the use of an edge-enhancing kernel. Conclusion The sensitivity of MDTCA for the detection of in-stent stenosis is insufficient to use this test to select patients for further invasive testing as with this strategy around 20% of the patients with in-stent stenosis would be missed. Further improvement of scanner technology is needed before it can be recommended as a triage instrument in practice. In addition, the number of non-assessable stents is also high. PMID:18671850

  12. Electrocardiogram-Gated 320-Slice Multidetector Computed Tomography for the Measurement of Pulmonary Arterial Distensibility in Chronic Thromboembolic Pulmonary Hypertension

    PubMed Central

    Kasai, Hajime; Sugiura, Toshihiko; Tanabe, Nobuhiro; Sakurai, Yoriko; Yahaba, Misuzu; Matsuura, Yukiko; Shigeta, Ayako; Kawata, Naoko; Sakao, Seiichiro; Kasahara, Yasunori; Tatsumi, Koichiro

    2014-01-01

    Background We aimed to study whether pulmonary arterial distensibility (PAD) correlates with hemodynamic parameters in chronic thromboembolic pulmonary hypertension (CTEPH) using electrocardiogram (ECG)-gated 320-slice multidetector computed tomography (MDCT). Methods and Findings ECG-gated 320-slice MDCT and right heart catheterization (RHC) was performed in 53 subjects (60.6±11.4 years old; 37 females) with CTEPH. We retrospectively measured the minimum and maximum values of the cross sectional area (CSA) of the main pulmonary artery (mainPA), right pulmonary artery (rtPA), and left pulmonary artery (ltPA) during one heartbeat. PAD was calculated using the following formula: PAD = [(CSAmaximum−CSAminimum)/CSAmaximum]×100(%). The correlation between hemodynamic parameters and PAD was assessed. Mean pulmonary arterial pressure (mPAP) and pulmonary vascular resistance (PVR) were 40.8±8.7 mmHg and 8.3±3.0 wood units, respectively. PAD values were as follows: mainPA (14.0±5.0%), rtPA (12.8±5.6%), and ltPA (9.7±4.6%). Good correlations existed between mainPAD, with mPAP (r = −0.594, p<0.001) and PVR (r = −0.659, p<0.001). The correlation coefficients between rtPAD and ltPAD with pulmonary hemodynamics were all lower or equal than for mainPAD. Conclusions PAD measured using ECG-gated 320-slice MDCT correlates with pulmonary hemodynamics in subjects with CTEPH. The mainPA is suitable for PAD measurement. PMID:25365168

  13. Transmural myocardial perfusion gradients in relation to coronary artery stenoses severity assessed by cardiac multidetector computed tomography.

    PubMed

    Linde, Jesper James; Kühl, Jørgen Tobias; Hove, Jens Dahlgaard; Sørgaard, Mathias; Kelbæk, Henning; Nielsen, Walter Bjørn; Kofoed, Klaus Fuglsang

    2015-01-01

    To assess the relationship between epicardial coronary artery stenosis severity and the corresponding regional transmural perfusion at rest and during adenosine stress, using multidetector computed tomography (MDCT). We evaluated the relationship between the severity of coronary artery diameter stenosis assessed by MDCT angiography and semi-quantitative myocardial MDCT perfusion in 200 symptomatic patients. The perfusion index (PI = mean myocardial attenuation density/mean left ventricular lumen attenuation density) at rest and during adenosine stress, the myocardial perfusion reserve (MPR = stress - PI/rest - PI), and the transmural perfusion ratio (TPR = subendocardium/subepicardium) were calculated. A coronary artery stenosis ≥50 % was present in 49 patients (25 %). Rest-PI and rest-TPR values were similar in patients with and without a coronary artery stenosis ≥50 %, whereas stress-PI, stress-TPR and MPR were significantly reduced in patients with a stenosis ≥50 % (p < 0.001, p < 0.0001 and p = 0.02, respectively). Subendocardial PI was significantly higher than subepicardial PI at rest and during stress for patients without a significant stenosis, whereas this difference was blurred during stress in patients with ≥50 % stenosis. In a broad spectrum of stenosis severity groups, TPR at rest remained unchanged until the group of patients with total occlusions, whereas TPR during stress decreased progressively when a threshold of 50 % was superseded. In this study we establish the relationship between semi-quantitative perfusion measurements by MDCT and severity of coronary artery stenoses and find the transmural myocardial perfusion ratio to be a potential strong functional index of the hemodynamic significance of coronary artery atherosclerotic lesions.

  14. Comparison of the accuracy of multidetector computed tomography versus two-dimensional echocardiography to measure left atrial volume.

    PubMed

    Avelar, Erick; Durst, Ronen; Rosito, Guido A; Thangaroopan, Molly; Kumar, Simi; Tournoux, Francois; Chan, Raymond C; Hung, Judy; Hoffmann, Udo; Abbara, Suhny; Brady, Thomas; Cury, Ricardo C

    2010-07-01

    Left atrial (LA) volume is an important prognostic factor in cardiovascular disease. Multidetector computed tomography (MDCT) is an emerging cardiac imaging modality; however, its accuracy in measuring the LA volume has not been well studied. The aim of our study was to determine the accuracy of MDCT in quantifying the LA volume. A total of 48 patients underwent MDCT and 2-dimensional (2D) echocardiography (2DE) on the same day. The area-length and Simpson's methods were used to obtain the 2D echocardiographic LA volume. The LA volume assessment by MDCT was obtained using the modified Simpson's method. Four artificial phantoms were created, and their true volume was assessed by an independent observer using both imaging modalities. The correlation between the LA volume by MDCT and 2DE was significant (r = 0.68). The mean 2D echocardiographic LA volume was lower than the LA volume obtained with MDCT (2DE 79 +/- 37 vs MDCT 103 +/- 32, p <0.05). In the phantom experiment, the volume obtained using MDCT and 2DE correlated significantly with the true volume (r = 0.97, p <0.05 vs r = 0.96, p <0.05, respectively). However, the mean 2D echocardiographic phantom volume was 16% lower than the true volume (2DE, Simpson's method 53 +/- 24 vs the true volume 61 +/- 24, p <0.05). The mean volume calculated using MDCT did not differ from the true volume (MDCT 60 +/- 21 vs true volume 61 +/- 24, p = NS). 2DE appeared to systematically underestimate the LA volume compared to phantom and cardiac MDCT, suggesting that different normal cutoff values should be used for each modality. In conclusion, LA volume quantification using MDCT is an accurate and feasible method. PMID:20609656

  15. Prediction of Small Bowel Obstruction Caused by Bezoars Using Risk Factor Categories on Multidetector Computed Tomographic Findings

    PubMed Central

    Kuang, Lian-qin; Cheng, Cheng

    2016-01-01

    Objectives. The aim of this study was to detect factors associated with small bowel obstruction (SBO) caused by bezoars on multidetector computed tomographic findings. Methods. We retrospectively reviewed 61 patients who had bezoars in the small bowels on MDCT. The patients were divided into SBO patients group and non-SBO patients group. The mean values of the diameter, volume, and CT attenuation as well as location and characteristics of the bezoars were compared between the two groups. Multivariate analysis was performed to determine factors associated with SBO. Results. There were 32 patients (52.5%) in the SBO group and 29 patients (47.5%) in the non-SBO group. The bezoars in the SBO group had greater values of each mean diameter and mean volume than those in the non-SBO group (3.2 ± 0.5 cm versus 1.6 ± 0.7 cm, P < 0.0001, 14.9 ± 6.4 cm3 versus 2.5 ± 2.7 cm3, P < 0.0001, resp.) and had a lower CT attenuation than the non-SBO group (55.5 ± 23.4 versus 173.0 ± 68.0, P < 0.0001). The SBO group had higher prevalence of phytobezoar appearance (75.0% versus 10.3%, P < 0.0001). Major diameters of bezoar and phytobezoar were significant independent risk factors associated with SBO (odds ratio = 36.09, 8.26, resp., and P = 0.0004, 0.044, resp.). Conclusions. Major diameter of bezoar or phytobezoar is a potential risk factor associated with SBO. PMID:27403434

  16. Sequential radial artery for coronary artery bypass grafting: five-year follow-up and evaluation with multi-detector row computed tomography.

    PubMed

    Emir, Mustafa; Kunt, Ayşe Gül; Çiçek, Murat; Bozok, Şahin; Karakişi, Sedat Ozan; Uğuz, Emrah; Hidiroğlu, Mete; Çetin, Levent; Şener, Erol

    2012-01-01

    This study was undertaken to compare early postoperative results, programmed multi-detector row computed tomography coronary angiographic patency and midterm results of revascularization by sequential radial artery grafting with those of single radial artery grafting during a five-year period. Patients were grouped as those with sequential radial artery grafts (Group A, n = 27) and single radial artery grafts (Group B, n = 26). Multi-detector row computed tomography coronary angiography was scheduled at 1 and 5 years postoperatively. Each distal anastomosis was accepted as nonfunctional if a radial artery graft was occluded proximally or there was a critical stenosis. One sequential radial artery graft and two single radial artery grafts failed in the 1-year period (p>0.05). In the 5-year period, three radial artery grafts failed in each group (p>0.05). In Group A, there was no mortality in the five-year period, but in Group B, one patient died four years after the operation due to cardiac problems (p>0.05). In addition to one death in Group B, there were three percutaneous interventions and two myocardial infarctions among the 26 patients during the five-year follow-up. In group A, among 27 patients, there were 4 percutaneous interventions and one myocardial infarction (p>0.05). Although the sample size is relatively small to be conclusive, these data suggest that sequential radial artery grafting may be considered as a method of choice for maximizing arterial graft survival and patency. Noninvasive control of sequential and single radial artery grafts with multi-detector row computed tomography is feasible with no discomfort for the patient and excellent visualization of grafts. PMID:22889883

  17. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists

    PubMed Central

    Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M.

    2016-01-01

    Purpose To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. Methods As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Results Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = < .004). No significant differences were detected concerning the modalities’ specificities (with values between P = .98). Raters' confidence was higher in RED-MDCT and RED-CBCT compared to radiography (P < .001). Conclusion The diagnostic accuracy of RED-MDCT and RED-CBCT for wrist fractures proved to be similar and in some parts even higher compared to radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run. PMID:27788215

  18. Clinical structural anatomy of the inferior pyramidal space reconstructed from the living heart: Three-dimensional visualization using multidetector-row computed tomography.

    PubMed

    Mori, Shumpei; Nishii, Tatsuya; Takaya, Tomofumi; Kashio, Kazuhiro; Kasamatsu, Akira; Takamine, Sachiko; Ito, Tatsuro; Fujiwara, Sei; Kono, Atsushi K; Hirata, Ken-Ichi

    2015-10-01

    The inferior pyramidal space (IPS) comprises the epicardial visceral adipose tissue wedged between the bottoms of the four cardiac chambers from the postero-inferior epicardial surface of the heart. Understanding the complex anatomy around the IPS is important for clinical cardiologists. Although leading anatomists and radiologists have clarified the anatomy of the IPS in detail, few studies have demonstrated this anatomy in three dimensions. The aim of this study was to visualize the three-dimensional anatomy of the IPS reconstructed from the living heart using multidetector-row computed tomography. We also developed an original paper model of the IPS to enhance understanding of its intricate structure.

  19. Clinical application of 320-row multidetector computed tomography for a dynamic three-dimensional vascular study: imaging findings and initial experience.

    PubMed

    Nagamatsu, Shogo; Nakagawa, Masahiro; Kayano, Shuji; Koizumi, Takuya; Akazawa, Satoshi; Onitsuka, Tetsuro; Iida, Yoshiyuki; Endo, Masahiro; Nakaya, Yoshihiro; Urikura, Atsushi

    2010-10-01

    The 320-row multidetector computed tomography (MDCT) is now used by both cardiologists and neurosurgeons. It enables dynamic 3D-CT angiography, because the wide-area detector eliminates helical scanning, thus achieving very fast scanning times for single 3D-CT volume data. Some microvascular surgeons are familiar with 64-row MDCT for perforator studies, but there are few reports of studies using 320-row MDCT. This MDCT system was used to follow the dynamic blood flow of small vessels. It is considered to have a great potential in the clinical field of microvascular surgery. PMID:20399163

  20. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws: A Phantom Study.

    PubMed

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M

    2015-08-01

    To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy.The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences.Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting. PMID:26252281

  1. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws

    PubMed Central

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M.

    2015-01-01

    Abstract To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner. We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy. The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences. Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting. PMID:26252281

  2. Stature estimation from skull measurements using multidetector computed tomographic images: A Japanese forensic sample.

    PubMed

    Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Yamaguchi, Rutsuko; Hashimoto, Mari; Hoshioka, Yumi; Iwase, Hirotaro

    2016-01-01

    The aim of this study was to assess the correlation between stature and cranial measurements in a contemporary Japanese population, using three-dimensional (3D) computed tomographic (CT) images. A total of 228 cadavers (123 males, 105 females) underwent postmortem CT scanning and subsequent forensic autopsy between May 2011 and April 2015. Five cranial measurements were taken from 3D CT reconstructed images that extracted only cranial data. The correlations between stature and each of the cranial measurements were assessed with Pearson product-moment correlation coefficients. Simple and multiple regression analyses showed significant correlations between stature and cranial measurements. In conclusion, cranial measurements obtained from 3D CT images may be useful for forensic estimation of the stature of Japanese individuals, particularly in cases where better predictors, such as long bones, are not available.

  3. A radioanatomic study of the internal mammary artery and its perforators using multidetector computed tomography angiography.

    PubMed

    Tan, Onder; Yuce, Ihsan; Aydin, Osman Enver; Kantarci, Mecit

    2014-05-01

    The Internal Mammary Artery (IMA) and its perforators play an important role in coronary bypass grafting and reconstructive breast, head, and neck surgery. This study aimed to obtain anatomic data pertaining to these vessels using Multi Detector Computed Tomography Angiography (MDCTA) and to demonstrate that the MDCTA could be a considerable assessment tool prior to surgery. In 50 outpatients (27 males and 23 females), the above-mentioned arteries were bilaterally evaluated with a 16-detector spiral computed tomography scanner. Based on the obtained images, diameters of the bilateral IMAs were separately measured in each intercostal spaces from 1 to 5 through their traces. IMAPs greater than 0.5 mm in diameter were bilaterally evaluated in terms of distance from the sternal border to the ramification point under the muscular layer, maximal external diameter at ramification from the IMA, and the length between the ramification point from the IMA and enter point to the subcutaneous fat tissue. Mean diameters of the left and right IMAs were 2.05 ± 0.50 mm and 2.20 ± 0.57 mm, respectively. Mean diameters, distances, and lengths of the perforators were 1.30 ± 0.30 mm, 6.80 ± 3.40 mm, 17.05 ± 6.07 mm on the left side and 1.32 ± 0.25 mm, 6.71 ± 3.43 mm, 17.35 ± 3.48 mm on the right side, respectively. No statistically difference was found between the sides (P > 0.05). About 20 of 36 perforators appeared in the second intercostal space, whereas there were eight in the first and eight in the third intercostal space. MDCTA, as a non-invasive vascular imaging method, can be a valuable tool for investigating the anatomic characteristics of the IMA and its perforators before planning an operation. PMID:24105707

  4. Candida prosthetic valve endocarditis: the complementary role of multidetector computed tomography and transoesophageal echocardiography in preoperative evaluation.

    PubMed

    Ghersin, E; Lessick, J; Agmon, Y; Engel, A; Kophit, A; Adler, Z

    2007-12-01

    A 72-year-old man with previous mitral valve replacement and single coronary bypass surgery was diagnosed with recurrent candida endocarditis by transoesophageal echocardiography and positive blood cultures. Preoperative electrocardiogram-gated multidetector CT (MDCT) was ordered to evaluate the patency and course of the mammary graft. In addition to verifying graft patency, MDCT demonstrated a mobile vegetation on the mitral prosthesis as well as a vegetation on the posterior left atrial wall which was not visible by transoesophageal echocardiography. Multidetector CT also revealed signs of osteomyelitis in the thoracic spine. Repeated surgery confirmed these findings and mitral valve replacement with resection of the left atrial vegetation were performed. This case illustrates the complementary role of MDCT and echocardiography in the preoperative evaluation of fungal endocarditis.

  5. Prevalence of extracardiac findings in the evaluation of ischemic heart disease by multidetector computed tomography

    PubMed Central

    Cho, Jeong-Hwan; Park, Jong-Seon; Shin, Dong-Gu; Kim, Young-Jo; Lee, Sang-Hee; Choi, Yoon-Jung; Cho, Ihn-Ho

    2013-01-01

    Objective Multidector computed tomography (MDCT) is now commonly used for the evaluation of coronary artery disease. Because MDCT images include many non-cardiac organs and the patient population evaluated is highly susceptible to extracardiac diseases, this study was designed to evaluate the prevalence of extracardiac findings in the MDCT evaluation of ischemic heart disease. Methods From March 2007 to March 2008, a total of six-hundred twenty patients, who underwent 64-slice MDCT evaluations for chest pain, or dyspnea, were enrolled in this study. Cardiac and non-cardiac findings were comprehensively evaluated by a radiologist. Results Enrolled patients included 306 men (49.4%), with a mean age of 66 years. Significant coronary artery stenosis was found in 41.6% of the patients. A total of 158 extracardiac findings were observed in 110 (17.7%) patients. Commonly involved extracardiac organs were lung (36.7%), hepatobiliary system (21.5%), thyroid (19.6%), kidney (10.8%), spine (9.7%) and breast (0.6%). Of those 110 patients, 50 (45.5%) patients underwent further diagnostic investigations. Malignant disease was detected in three (2.7%) patients (lung cancer, pancreatic cancer, and thyroid cancer). Conclusions Extracardiac findings are frequently present and should be a concern in the MDCT evaluation of chest pain syndrome. PMID:24133511

  6. Effect of obesity on coronary artery plaque using 64 slice multidetector cardiac computed tomography angiography.

    PubMed

    Isma'eel, Hussain; Tellalian, David; Hamirani, Yasmin S; Kadakia, Jigar; Nasir, Khurram; Budoff, Matthew J

    2010-04-30

    Patients with a coronary artery calcification score (CACS) of zero and an intermediate risk of coronary artery disease have been shown to have a low prevalence of non-calcified coronary artery plaque (NCP). 181 consecutive patients with CAC 'zero', undergoing cardiac computed tomography angiography (CCTA) angiography at our center were evaluated. Presence of detectable NCP on CCTA in these patients was 13.8%. Mild non-obstructive disease (<30% and limited to one segment) was present in 76% of patients while only one patient (0.6%) had significant stenosis (>50%). Traditional risk factors were not found to be associated with the presence of NCP. However higher body mass index (BMI) was strongly found to be associated with NCP (31.6 in patients with NCP vs. 27.6 kg/m(2) in patients without NCP, p<.05). Obesity was 2.76 times more likely to be associated with NCP as compared to normal BMI (p<0.05).

  7. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    PubMed

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P < 0.0001). Breeds with increased risk for duplicated caudal vena cava were Yorkshire Terrier (odds ratio [OR] = 6.41), Poodle (OR = 7.46), West Highland White Terrier (OR = 6.33), and Maltese (OR = 3.87). Presence of a duplicated caudal vena cava was significantly associated with presence of extrahepatic portosystemic shunt(s) (P < 0.004). While uncommon in dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses.

  8. Efficacy of Multidetector-Row Computed Tomography as a Practical Tool in Comparison to Invasive Procedures for Visualization of the Biliary Obstruction

    PubMed Central

    Taheri, Abdolmajid; Rostamzadeh, Ayoob; Gharib, Alireza; Fatehi, Daryoush

    2016-01-01

    Introduction: Recently, multidetector computed tomography (MDCT) has been introduced into clinical practice. MDCT has become the noninvasive diagnostic test of choice for detailed evaluation of biliary obstruction. Aim: the main objective of the present study was to evaluate the diagnostic value of MDCT compared to invasive procedures for detecting biliary obstruction causes. Material and Methods: Since February 2009 until May 2011 fifty biliary obstruction patients based on clinical, laboratory or ultrasonographic findings, were evaluated by Multidetector-row computed tomography. The causes of biliary obstruction, which was identified using. MDCT were classified into three categories: calculus, benign stricture, and malignancy. Final diagnosis was conducted based on percutaneous transhepatic cholangiography (PTC), endoscopic retrograde cholangiopancreatography, biopsy, or surgery. The MDCT diagnosis and were compared with the final diagnosis. Results: A correct diagnosis of causes of biliaryobstruction was made on the basis of MDCT findings for 44 of the total 50 patients. Two patients with chronic pancreatitis were incorrectly diagnosed with a pancreatic head adenocarcinoma on the basis of MDCT findings. One patient with biliary stone was incorrectly diagnosed with a periampullary adenocarcinoma on the basis of MDCT findings. The Sensitivity, specificity and accuracy of MDCT in the diagnosis of causes of biliary obstruction were 94.12% and87.87% and94.6% respectively. Conclusion: Based on the findings of this study MDCT has an excellent image quality, providing valuable information about the biliary tree and other abdominal organs. The use of advanced image processing, including maximum intensity projection and multiplanar reconstruction (especially coronal or sagittal reformatted images), allows superior visualization of the biliary tree and vascular structures. Three-dimensional reconstruction images complement axial images by providing a more anatomically

  9. Gadolinium Ethoxybenzyl Diethylenetriamine Pentaacetic Acid (Gd-EOB-DTPA)-Enhanced Magnetic Resonance Imaging and Multidetector-Row Computed Tomography for the Diagnosis of Hepatocellular Carcinoma

    PubMed Central

    Ye, Feng; Liu, Jun; Ouyang, Han

    2015-01-01

    Abstract The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC). Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis. Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT. PMID:26266348

  10. Multi-Detector Row Computed Tomographic Evaluation of a Rare Type of Complete Vascular Ring: Double Aortic Arch with Atretic Left Arch Distal to the Origin of Left Subclavian Artery

    PubMed Central

    Hung, Ying-Ying; Fu, Yun-Ching; Wei, Hao-Ji; Chen, Clayton Chi-Chang

    2013-01-01

    Double aortic arch with an atretic left arch distal to the origin of left subclavian artery was diagnosed with multi-detector row computed tomography (MDCT) in two children with dysphagia. This rare type of complete vascular ring is clinically important because it may be confused with right aortic arch in mirror imaging. Anatomic details of this rare type of complete vascular ring demonstrated on MDCT facilitated appropriate surgical treatment. PMID:24043984

  11. Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

    SciTech Connect

    Baumann, Clemens Fuchs, Heiko; Westphalen, Kerstin; Hierholzer, Johannes

    2008-11-15

    The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190{sup o}; 1.5{sup o} per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's {kappa}-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, {kappa} = 0.008) to intermediate (trace of vertebroplasty canula; {kappa} = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with {kappa} values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of {kappa} = 0.768 ('good correlation') and a maximum of {kappa} = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

  12. Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    SciTech Connect

    Fanelli, Fabrizio Bezzi, Mario; Bruni, Antonio; Corona, Mario; Boatta, Emanuele; Lucatelli, Pierleone; Passariello, Roberto

    2011-02-15

    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

  13. Usefulness of Multidetector Row Computed Tomography for Predicting Cardiac Events in Asymptomatic Chronic Kidney Disease Patients at the Initiation of Renal Replacement Therapy

    PubMed Central

    Lee, Jung Eun; Lee, Yong Kyu; Choi, Eun Jeong; Nam, Ji Sun; Choi, Byoung Wook

    2013-01-01

    Background. The prevalence of coronary artery stenosis (CAS) at the initiation of renal replacement therapy (RRT) in chronic kidney disease (CKD) patients has not been fully elucidated. Although coronary angiography is the gold standard in diagnosing CAS its invasiveness and economic burden lead to searching for a noninvasive alternative method. In this study, we evaluated the prevalence of CAS by multidetector row computed tomography (MDCT) and related risk factor to articulate the usefulness of MDCT. Method. Seventy-four asymptomatic CKD patients who began dialysis were evaluated with echocardiography and MDCT. The patients were stratified into two groups according to CAS and coronary artery calcification score (CACS) by MDCT to detect silent CAS and evaluate its predictability for cardiac events. Results. CAS was seen in 24 (32.4%) of 74 asymptomatic CKD patients on MDCT. Both groups showed increasing frequencies of CAS with age (P < 0.01), presence of diabetes (P < 0.05), uric acid level (P < 0.01), and calcium score (P < 0.01). Multiple regression analysis revealed that age and uric acid level were independent risk factors for CAS and high CACS in asymptomatic CKD patients at the initiation of dialysis. Patients with both CAS and high CACS were presented with higher cardiac events rates compared to those without any of them. In Cox regression model, age and the presence of CAS and high CACS on MDCT were an independent risk factor for cardiac events in these patients. Conclusion. We showed that CAS was highly seen in asymptomatic CKD patients starting dialysis. Moreover, both high CACS and CAS on MDCT might predict cardiac events in these patients and MDCT can be a useful screening tool for evaluating coronary artery disease and predicting cardiovascular mortality noninvasively. PMID:24363626

  14. Perforated duodenal ulcer presenting with a subphrenic abscess revealed by plain abdominal X-ray films and confirmed by multi-detector computed tomography: a case report

    PubMed Central

    2013-01-01

    Introduction Peptic ulcer disease is still the major cause of gastrointestinal perforation despite major improvements in both diagnostic and therapeutic strategies. While the diagnosis of a perforated ulcer is straightforward in typical cases, its clinical onset may be subtle because of comorbidities and/or concurrent therapies. Case presentation We report the case of a 53-year-old Caucasian man with a history of chronic myeloid leukemia on maintenance therapy (100mg/day) with imatinib who was found to have a subphrenic abscess resulting from a perforated duodenal ulcer that had been clinically overlooked. Our patient was febrile (38.5°C) with abdominal tenderness and hypoactive bowel sounds. On the abdominal plain X-ray films, a right subphrenic abscess could be seen. On contrast-enhanced multi-detector computed tomography, a huge air-fluid collection extending from the subphrenic to the subhepatic anterior space was observed. After oral administration of 500cm3 of 3 percent diluted diatrizoate meglumine, an extraluminal leakage of the water-soluble iodinated contrast media could then be appreciated as a result of a perforated duodenal ulcer. During surgery, the abscess was drained and extensive adhesiolysis had to be performed to expose the duodenal bulb where the ulcer was first identified by methylene blue administration and then sutured. Conclusions While subphrenic abscesses are well known complications of perforated gastric or duodenal ulcers, they have nowadays become rare thanks to advances in both diagnostic and therapeutic strategies for peptic ulcer disease. However, when peptic ulcer disease is not clinically suspected, the contribution of imaging may be substantial. PMID:24215711

  15. Anthropometric Assessment of Neck Adipose Tissue and Airway Volume Using Multidetector Computed Tomography: An Imaging Approach and Association With Overall Mortality.

    PubMed

    Maresky, Hillel S; Sharfman, Zachary; Ziv-Baran, Tomer; Gomori, J M; Copel, Laurian; Tal, Sigal

    2015-11-01

    Neck adiposity tissue volume (NATV) accumulation is an indicator for metabolic syndrome and cardiovascular disease (CVD). Neck circumference is a poor measure of NATV, and a quantifier for this entity has not yet been established. To evaluate volumetric quantification by multidetector computed tomography (MDCT) as a reproducible anthropometric tool to measure NATV and airway volume (AWV). A total of 519 patients, including a subset of 70 random patients who underwent head and neck CT scanning in our hospital within 1 year (2013), were studied. Included patients were all those undergoing nonenhanced CT (NECT) or CT angiography (CTA). Neck cross-sectional areas (NCSA) were measured at 2 separate levels of the neck, and 3D postprocessing tissue reconstruction was performed, and NATV and AWVs were quantified volumetrically for all patients within the year. The average NCSA at the level of the soft palate and thyroid cartilage was 22,579 and 14,500 mm, respectively. NATV when compared to the upper and lower levels of NCSA showed correlations of 0.64 and 0.79, respectively (P < 0.001). Interobserver analysis showed mean deviations of 0.46% and 0.32% for NATV and AWV, respectively. A strong correlation between NATV and body mass index (BMI) was found (r = 0.658, P < 0.001), and the top quartile of NATV:AWV patients (out of 519 patients) displayed a statistically significant mortality rate during 670 days of follow-up (d = 7.5%, P = 0.032). After adjustment for age and gender, the association between NATV:AWV and mortality was close to significant (P = 0.072). Volumetric quantification of NATV and AWV is a reproducible and prognostic anthropometric tool, as a high NATV:AWV demonstrated a significant risk factor for mortality; future research may further advance our understanding of this phenomenon. PMID:26559286

  16. The role of multidetector computed tomography versus digital subtraction angiography in triaging care and management in abdominopelvic trauma

    PubMed Central

    Hallinan, James Thomas Patrick Decourcy; Tan, Cher Heng; Pua, Uei

    2016-01-01

    INTRODUCTION This study aimed to assess the ability of contrast-enhanced computed tomography (CECT) to detect active abdominopelvic haemorrhage in patients with blunt trauma, as compared to digital subtraction angiography (DSA). METHODS In this retrospective study, patients who underwent DSA within 24 hours following CECT for blunt abdominal and/or pelvic trauma were identified. The computed tomography (CT) trauma protocol consisted of a portal venous phase scan without CT angiography; delayed phase study was performed if appropriate. All selected CECT studies were independently reviewed for the presence of active extravasation of contrast by two radiologists, who were blinded to the DSA results. Fisher’s exact test was used to correlate the presence of extravasation on CT with subsequent confirmed haemorrhage on DSA. RESULTS During the eight-year study period, 51 patients underwent CECT prior to emergent DSA for abdominal or pelvic trauma. Evidence of active extravasation of contrast on CECT was observed in 35 patients and active haemorrhage was confirmed on DSA in 31 of these patients; embolisation was performed in all 31 patients. Two patients who were negative for active extravasation of contrast on CECT but positive for active haemorrhage on DSA had extensive bilateral pelvic fractures and haematomas. The sensitivity, specificity, and positive and negative predictive values of CECT in detecting active abdominopelvic haemorrhage, as compared to DSA, were 93.9%, 77.8%, 88.6% and 87.5%, respectively. CONCLUSION When compared with DSA, dual-phase CECT without CT angiography shows high sensitivity and positive predictive value for the detection of active haemorrhage in patients with blunt abdominopelvic trauma. PMID:26778466

  17. Comparison of accuracy of aortic root annulus assessment with cardiac magnetic resonance versus echocardiography and multidetector computed tomography in patients referred for transcatheter aortic valve implantation.

    PubMed

    Pontone, Gianluca; Andreini, Daniele; Bartorelli, Antonio L; Bertella, Erika; Mushtaq, Saima; Gripari, Paola; Loguercio, Monica; Cortinovis, Sarah; Baggiano, Andrea; Conte, Edoardo; Beltrama, Virginia; Annoni, Andrea; Formenti, Alberto; Tamborini, Gloria; Muratori, Manuela; Guaricci, Andrea; Alamanni, Francesco; Ballerini, Giovanni; Pepi, Mauro

    2013-12-01

    The evaluation of the aortic root in patients referred for transcatheter aortic valve implantation is crucial. The aim of the present study was to compare the accuracy of cardiac magnetic resonance (CMR) evaluation of the aortic annulus (AoA) with transthoracic and transesophageal echocardiography and multidetector computed tomography (MDCT) in patients referred for transcatheter aortic valve implantation. In 50 patients, maximum diameter, minimum diameter and AoA, length of the left coronary, right coronary, and noncoronary aortic leaflets, degree (grades 1 to 4) of aortic leaflet calcification, and distance between AoA and coronary artery ostia were assessed. AoA maximum diameter, minimum diameter, and area by CMR were 26.4 ± 2.8 mm, 20.6 ± 2.3 mm, 449.8 ± 86.2 mm(2), respectively. The length of left coronary, right coronary, and noncoronary leaflets by CMR were 13.9 ± 2.2, 13.3 ± 2.1, and 13.4 ± 1.8 mm, respectively, whereas the score of aortic leaflet calcifications was 2.9 ± 0.8. Finally, the distances between AoA and left main and right coronary artery ostia were 16.1 ± 2.8 and 16.1 ± 4.4 mm, respectively. Regarding AoA area, transthoracic and transesophageal echocardiography showed an underestimation (p <0.01), with a moderate agreement (r: 0.5 and 0.6, respectively, p <0.01) compared with CMR. No differences and excellent correlation were observed between CMR and MDCT for all parameters (r: 0.9, p <0.01), except for aortic leaflet calcifications that were underestimated by CMR. In conclusion, aortic root assessment with CMR including AoA size, aortic leaflet length, and coronary artery ostia height is accurate compared with MDCT. CMR may be a valid imaging alternative in patients unsuitable for MDCT. PMID:24045059

  18. Magnetic resonance imaging and multi-detector computed tomography assessment of extracellular compartment in ischemic and non-ischemic myocardial pathologies.

    PubMed

    Saeed, Maythem; Hetts, Steven W; Jablonowski, Robert; Wilson, Mark W

    2014-11-26

    Myocardial pathologies are major causes of morbidity and mortality worldwide. Early detection of loss of cellular integrity and expansion in extracellular volume (ECV) in myocardium is critical to initiate effective treatment. The three compartments in healthy myocardium are: intravascular (approximately 10% of tissue volume), interstitium (approximately 15%) and intracellular (approximately 75%). Myocardial cells, fibroblasts and vascular endothelial/smooth muscle cells represent intracellular compartment and the main proteins in the interstitium are types I/III collagens. Microscopic studies have shown that expansion of ECV is an important feature of diffuse physiologic fibrosis (e.g., aging and obesity) and pathologic fibrosis [heart failure, aortic valve disease, hypertrophic cardiomyopathy, myocarditis, dilated cardiomyopathy, amyloidosis, congenital heart disease, aortic stenosis, restrictive cardiomyopathy (hypereosinophilic and idiopathic types), arrythmogenic right ventricular dysplasia and hypertension]. This review addresses recent advances in measuring of ECV in ischemic and non-ischemic myocardial pathologies. Magnetic resonance imaging (MRI) has the ability to characterize tissue proton relaxation times (T1, T2, and T2*). Proton relaxation times reflect the physical and chemical environments of water protons in myocardium. Delayed contrast enhanced-MRI (DE-MRI) and multi-detector computed tomography (DE-MDCT) demonstrated hyper-enhanced infarct, hypo-enhanced microvascular obstruction zone and moderately enhanced peri-infarct zone, but are limited for visualizing diffuse fibrosis and patchy microinfarct despite the increase in ECV. ECV can be measured on equilibrium contrast enhanced MRI/MDCT and MRI longitudinal relaxation time mapping. Equilibrium contrast enhanced MRI/MDCT and MRI T1 mapping is currently used, but at a lower scale, as an alternative to invasive sub-endomyocardial biopsies to eliminate the need for anesthesia, coronary

  19. Stature estimation in Japanese cadavers based on pelvic measurements in three-dimensional multidetector computed tomographic images.

    PubMed

    Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Hayakawa, Mutsumi; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Iwase, Hirotaro

    2015-05-01

    The aim of this study was to examine the feasibility of stature estimation by measuring the pelvic bones of Japanese cadavers using three-dimensional (3D) computed tomography (CT). We assessed 3D reconstructed images of 210 Japanese subjects (108 males, 102 females) who had undergone postmortem CT between May 2011 and November 2013. We defined the linear distance from the anterosuperior margin of the left and right anterior superior iliac spines (ASIS) to the posterior margin of the left and right ischial spines as the LSS and RSS, respectively. We also defined the linear distance from the anterosuperior margin of the left and right ASIS to the anteroinferior margin of the left and right ischial tuberosities as the LST and RST, respectively. The correlation between the cadaver stature (CS) and each parameter (LSS, LST, RSS, and RST) was evaluated using Pearson product-moment correlation coefficients and regression analysis was performed for stature estimation. All four parameters correlated significantly with stature independent of sex, suggesting that they can be used as a tool for stature estimation. The LST had the closest correlation with stature in both sexes.

  20. Anatomy of the larynx and pharynx: effects of age, gender and height revealed by multidetector computed tomography.

    PubMed

    Inamoto, Y; Saitoh, E; Okada, S; Kagaya, H; Shibata, S; Baba, M; Onogi, K; Hashimoto, S; Katada, K; Wattanapan, P; Palmer, J B

    2015-09-01

    Although oropharyngeal and laryngeal structures are essential for swallowing, the three-dimensional (3D) anatomy is not well understood, due in part to limitations of available measuring techniques. This study uses 3D images acquired by 320-row area detector computed tomography ('320-ADCT'), to measure the pharynx and larynx and to investigate the effects of age, gender and height. Fifty-four healthy volunteers (30 male, 24 female, 23-77 years) underwent one single-phase volume scan (0.35 s) with 320-ADCT during resting tidal breathing. Six measurements of the pharynx and two of larynx were performed. Bivariate statistical methods were used to analyse the effects of gender, age and height on these measurements. Length and volume were significantly larger for men than for women for every measurement (P < 0.05) and increased with height (P < 0.05). Multiple regression analysis was performed to understand the interactions of gender, height and age. Gender, height and age each had significant effects on certain values. The volume of the larynx and hypopharynx was significantly affected by height and age. The length of pharynx was associated with gender and age. Length of the vocal folds and distance from the valleculae to the vocal folds were significantly affected by gender (P < 0.05). These results suggest that age, gender and height have independent and interacting effects on the morphology of the pharynx and larynx. Three-dimensional imaging and morphometrics using 320-ADCT are powerful tools for efficiently and reliably observing and measuring the pharynx and larynx.

  1. Role of multidetector computed tomography in the diagnosis and management of patients attending the rapid access chest pain clinic, The Scottish computed tomography of the heart (SCOT-HEART) trial: study protocol for randomized controlled trial

    PubMed Central

    2012-01-01

    Background Rapid access chest pain clinics have facilitated the early diagnosis and treatment of patients with coronary heart disease and angina. Despite this important service provision, coronary heart disease continues to be under-diagnosed and many patients are left untreated and at risk. Recent advances in imaging technology have now led to the widespread use of noninvasive computed tomography, which can be used to measure coronary artery calcium scores and perform coronary angiography in one examination. However, this technology has not been robustly evaluated in its application to the clinic. Methods/design The SCOT-HEART study is an open parallel group prospective multicentre randomized controlled trial of 4,138 patients attending the rapid access chest pain clinic for evaluation of suspected cardiac chest pain. Following clinical consultation, participants will be approached and randomized 1:1 to receive standard care or standard care plus ≥64-multidetector computed tomography coronary angiography and coronary calcium score. Randomization will be conducted using a web-based system to ensure allocation concealment and will incorporate minimization. The primary endpoint of the study will be the proportion of patients diagnosed with angina pectoris secondary to coronary heart disease at 6 weeks. Secondary endpoints will include the assessment of subsequent symptoms, diagnosis, investigation and treatment. In addition, long-term health outcomes, safety endpoints, such as radiation dose, and health economic endpoints will be assessed. Assuming a clinic rate of 27.0% for the diagnosis of angina pectoris due to coronary heart disease, we will need to recruit 2,069 patients per group to detect an absolute increase of 4.0% in the rate of diagnosis at 80% power and a two-sided P value of 0.05. The SCOT-HEART study is currently recruiting participants and expects to report in 2014. Discussion This is the first study to look at the implementation of computed

  2. User's manual for rocket combustor interactive design (ROCCID) and analysis computer program. Volume 2: Appendixes A-K

    NASA Technical Reports Server (NTRS)

    Muss, J. A.; Nguyen, T. V.; Johnson, C. W.

    1991-01-01

    The appendices A-K to the user's manual for the rocket combustor interactive design (ROCCID) computer program are presented. This includes installation instructions, flow charts, subroutine model documentation, and sample output files. The ROCCID program, written in Fortran 77, provides a standardized methodology using state of the art codes and procedures for the analysis of a liquid rocket engine combustor's steady state combustion performance and combustion stability. The ROCCID is currently capable of analyzing mixed element injector patterns containing impinging like doublet or unlike triplet, showerhead, shear coaxial and swirl coaxial elements as long as only one element type exists in each injector core, baffle, or barrier zone. Real propellant properties of oxygen, hydrogen, methane, propane, and RP-1 are included in ROCCID. The properties of other propellants can be easily added. The analysis models in ROCCID can account for the influences of acoustic cavities, helmholtz resonators, and radial thrust chamber baffles on combustion stability. ROCCID also contains the logic to interactively create a combustor design which meets input performance and stability goals. A preliminary design results from the application of historical correlations to the input design requirements. The steady state performance and combustion stability of this design is evaluated using the analysis models, and ROCCID guides the user as to the design changes required to satisfy the user's performance and stability goals, including the design of stability aids. Output from ROCCID includes a formatted input file for the standardized JANNAF engine performance prediction procedure.

  3. The Role of Virtual Cystoscopy, after Multidetector Computed Tomography Imaging Reconstruction without the Use of Contrast Medium, in the Diagnosis and Evaluations of Bladder Tumors: Preliminary Study.

    PubMed

    Kalokairinou, Kyriaki; Ploumidis, Achilles; Kalogeropoulos, Theodoros; Vlachos, Lampros; Stringaris, Kyriakos; Tavernaraki, Ageliki; Thanos, Anastasios; Papacharalampous, Xenofon; Koutoulidis, Vasilios; Letendre, Julien; Traxer, Olivier; Gouliamos, Athanasios

    2014-01-01

    Introduction. Although conventional cystoscopy is considered to be the gold standard for diagnosis and follow-up of bladder tumors, it remains an invasive and costly procedure. With the advent of the multidetector CT (MDCT) scanners supported by specialized software virtual cystoscopy (VC) is possible. We assess the role of VC in diagnosing and evaluating bladder lesions. Materials and Methods. Between September 2010 and October 2011, 25 consecutive patients with cystoscopically confirmed bladder tumor underwent VC. The radiologists involved in this prospective study were blinded to the exact findings. After draining any residual urine with a catheter, the bladder was retrogradely insufflated with 200-600 cc of air. No intravenous or intravesical contrast was used. MDCT scan was performed in supine and prone positions and three-dimensional reconstruction of the urinary bladder was performed. Results. The examination was well tolerated by all patients with no complications. In total, 43 lesions were detected both with conventional cystoscopy and VC. Tumor size measured by CT ranged from 3 to 80 mm in diameter. The pathological report revealed noninvasive transitional cell carcinomas in all cases. Conclusion. VC has promising results in detecting exophytic bladder lesions. In the future it could be part of the diagnostic algorithm for bladder tumors. PMID:24799894

  4. Newer cardiac imaging techniques: multidetector CT angiography.

    PubMed

    Davidoff, Ravin; Ruberg, Frederick L

    2006-01-01

    An update of new developments with multidetector computed tomography (MDCT) coronary angiography is presented. Similar to what has occurred with the introduction of other new technologies such as electron beam computed tomography (EBCT), life insurance medical directors are expected to evaluate a technology before there are sufficient data from large clinical trials. Well-performed studies of the performance of MDCT coronary angiography have only recently appeared. MDCT appears to perform well for excluding significant coronary disease, and will perhaps be useful in emergency room "rule-out" situations. Other applications may be for the diagnosis of significant coronary obstruction (> 75% stenosis), as well as for the evaluation of bypass grafts. Limitations include the requirement for radiologic contrast administration and significant radiation exposure. MDCT does not provide information on atheroma morphology. Given these limitations, MDCT coronary angiography utilization will grow, and it will prove to be a useful tool in specific situations. PMID:16845845

  5. Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography.

    PubMed

    Marano, Riccardo; Storto, Maria Luigia; Maddestra, Nicola; Bonomo, Lorenzo

    2004-08-01

    The purpose of this study was to assess the accuracy of four-row multi-detector CT (MDCT) in the evaluation of coronary artery bypass graft (CABG) in patients with at least a left internal mammary artery (LIMA) grafted to the left anterior descending artery (LAD), because of the conduit of choice in bypass surgery and the greater difficulty of evaluation with non-invasive diagnostic tools. Included in the study were 57 patients with a total of 122 grafts (95 arterial and 27 venous) who underwent MDCT (4x2.5-mm detector-collimation, 3-mm slice width, 1.5-mm reconstruction increment) with retrospective ECG gating. Twelve patients (21%) with high heart rates were given beta-blockers in order to obtain a heart rate lateral>posterior-inferior wall; P=0.002). In the remaining 30 patent grafts (33%), the assessment of stenoses was hampered by surgical clips, calcifications and motion artifacts. Sensitivity and specificity of MDCT for detection of significant graft stenoses were 80 and 96%, respectively. Inter-observer agreement was good ( K=0.73). MDCT seems to be a valuable diagnostic tool for non-invasive assessment of patency of both venous and arterial grafts. An accurate evaluation

  6. Reproducibility of coronary atherosclerotic plaque characteristics in populations with low, intermediate, and high prevalence of coronary artery disease by multidetector computer tomography: a guide to reliable visual coronary plaque assessments.

    PubMed

    de Knegt, Martina C; Linde, Jesper J; Fuchs, Andreas; Nordestgaard, Børge G; Køber, Lars V; Hove, Jens D; Kofoed, Klaus F

    2016-10-01

    To evaluate the interobserver agreement of visual coronary plaque characteristics by 320-slice multidetector computed tomography (MDCT) in three populations with low, intermediate and high CAD prevalence and to identify determinants for the reproducible assessment of these plaque characteristics. 150 patients, 50 asymptomatic subjects from the general population (low CAD prevalence), 50 symptomatic non-acute coronary syndrome (non-ACS) patients (intermediate CAD prevalence), and 50 ACS patients (high CAD prevalence), matched according to age and gender, were retrospectively enrolled. All coronary segments were evaluated for overall image quality, evaluability, presence of CAD, coronary stenosis, plaque composition, plaque focality, and spotty calcification by four readers. Interobserver agreement was assessed using Fleiss' Kappa (κ) and intra-class correlation (ICC). Widely used clinical parameters (overall scan quality, presence of CAD, and determination of coronary stenosis) showed good agreement among the four readers, (ICC = 0.66, κ = 0.73, ICC = 0.74, respectively). When accounting for heart rate, body mass index, plaque location, and coronary stenosis above/below 50 %, interobserver agreement for plaque composition, presence of CAD, and coronary stenosis improved to either good or excellent, (κ = 0.61, κ = 0.81, ICC = 0.78, respectively). Spotty calcification was the least reproducible parameter investigated (κ = 0.33). Across subpopulations, reproducibility of coronary plaque characteristics generally decreased with increasing CAD prevalence except for plaque composition, (limits of agreement: ±2.03, ±1.96, ±1.79 for low, intermediate and high CAD prevalence, respectively). 320-slice MDCT can be used to assess coronary plaque characteristics, except for spotty calcification. Reproducibility estimates are influenced by heart rate, body size, plaque location, and degree of luminal stenosis.

  7. Three-dimensional multi-detector row CT portal venography in the evaluation of portosystemic collateral vessels in liver cirrhosis.

    PubMed

    Kang, Heoung Keun; Jeong, Yong Yeon; Choi, Jun Ho; Choi, Song; Chung, Tae Woong; Seo, Jeong Jin; Kim, Jae Kyu; Yoon, Woong; Park, Jin Gyoon

    2002-01-01

    Multi-detector row computed tomography (CT) offers distinct advantages over traditional spiral CT. Multi-detector row CT scanners are faster and allow thinner collimation than single-detector row spiral CT scanners. The use of multi-detector row CT combined with postprocessing of the imaging data with a variety of three-dimensional reformatting techniques (eg, maximum intensity projection, shaded surface display, volume rendering) allows creation of vascular maps whose quality equals or exceeds that of maps created at classic angiography for many applications. Three-dimensional multi-detector row CT portal venography can help determine the extent and location of portosystemic collateral vessels (eg, left gastric vein, short gastric vein, esophageal and paraesophageal varices, splenorenal and gastrorenal shunts, paraumbilical and abdominal wall veins) in patients with liver cirrhosis and is probably the optimal imaging technique in this setting.

  8. Non-invasive detection of aortic and coronary atherosclerosis in homozygous familial hypercholesterolemia by 64 slice multi-detector row computed tomography angiography.

    PubMed

    Santos, Raul D; Miname, Marcio H; Martinez, Lilton R C; Rochitte, Carlos E; Chacra, Ana P M; Nakandakare, Edna R; Chen, David; Schaefer, Ernst J

    2008-04-01

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row computed tomographic coronary angiography (CTCA). We studied five HoFH patients (three females, two males, mean age 19.8+/-2.9 years, age range 15-23 years, with a mean low density lipoprotein (LDL) cholesterol 618+/-211 mg/dL) using 64 slice CTCA. None of the patients showed evidence of ischemia with standard exercise testing. Calcified and mixed atherosclerotic plaques adjacent to or compromising the coronary artery ostia were found in all study subjects. Coronary plaques causing significant obstruction were found in one patient, who had previously undergone coronary artery bypass surgery and aortic valve replacement. Two other patients were noted to have non-obstructive calcified, mixed and non-calcified coronary artery plaques. Our data suggest that CTCA could be a useful non-invasive method for detection of early aortic and coronary atherosclerosis specifically affecting the coronary ostia in HoFH subjects. PMID:17884061

  9. Earthquake-related Crush Injury versus Non-Earthquake Injury in Abdominal Trauma Patients on Emergency Multidetector Computed Tomography: A Comparative Study

    PubMed Central

    Chen, Tian-wu; Dong, Zhi-hui; Chu, Zhi-gang; Tang, Si-shi; Deng, Wen

    2011-01-01

    The aim of this study was to investigate features of abdominal earthquake-related crush traumas in comparison with non-earthquake injury. A cross sectional survey was conducted with 51 survivors with abdominal crush injury in the 2008 Sichuan earthquake, and 41 with abdominal non-earthquake injury, undergoing non-enhanced computed tomography (CT) scans, serving as earthquake trauma and control group, respectively. Data were analyzed between groups focusing on CT appearance. We found that injury of abdominal-wall soft tissue and fractures of lumbar vertebrae were more common in earthquake trauma group than in control group (28 vs 13 victims, and 24 vs 9, respectively; all P < 0.05); and fractures were predominantly in transverse process of 1-2 vertebrae among L1-3 vertebrae. Retroperitoneal injury in the kidney occurred more frequently in earthquake trauma group than in control group (29 vs 14 victims, P < 0.05). Abdominal injury in combination with thoracic and pelvic injury occurred more frequently in earthquake trauma group than in control group (43 vs 29 victims, P < 0.05). In conclusion, abdominal earthquake-related crush injury might be characteristic of high incidence in injury of abdominal-wall soft tissue, fractures of lumbar vertebrae in transverse process of 1-2 vertebrae among L1-3 vertebrae, retroperitoneal injury in the kidney, and in combination with injury in the thorax and pelvis. PMID:21394315

  10. Extrahepatic, nonneoplastic, fat-containing lesions of the abdominopelvic cavity: spectrum of lesions, significance, and typical appearance on multidetector computed tomography.

    PubMed

    Kani, Kimia Khalatbari; Moshiri, Mariam; Bhargava, Puneet; Kolokythas, Orpheus

    2012-01-01

    Fat may be noted in a diffuse or focal manner in a variety of nonneoplastic abdominopelvic conditions. The specific signature of macroscopic fat on computed tomography along with the usually characteristic findings of these entities makes the diagnosis of most of these conditions relatively straightforward. In the intestinal tract, the "fat halo sign" usually arises in the context of subacute to chronic bowel wall inflammation. Excess fat in the renal sinus may occur with renal sinus lipomatosis or "replacement lipomatosis of the kidney." Some cases of "pancreatic lipomatosis" may culminate in steatopancreatitis and ultimately neoplastic transformations. "Fibrofatty mesenteric proliferation" is a characteristic feature of Crohn disease. In the setting of the acute abdomen, accurate diagnosis of fat-containing lesions (epiploic appendagitis or omental infarction) from other causes of the acute abdomen is critical. Mesenteric panniculitis is 1 of the causes of the "misty mesentery." Juxtacaval fat deposition is a benign process that has the potential to be confused with more serious conditions. More diffuse fat deposition (abdominal or pelvic lipomatosis) has the potential to become symptomatic by causing mass effect upon the adjacent structures. Fat can also be seen in a variety of postoperative/iatrogenic conditions or abdominal wall/diaphragmatic hernias. PMID:22285003

  11. [Multidetector computed tomography in acute abdomen].

    PubMed

    Carreras Aja, M; Arrieta Artieda, I; Borruel Nacenta, S

    2011-10-01

    MDCT has become a fundamental tool for determining the causes of acute abdomen. CT is considered the imaging technique of choice in the diagnostic workup of both localized and diffuse acute abdomen, except in patients in whom acute cholecystitis or acute gynecological disease is suspected and in children, adolescents, and pregnant patients, in whom ultrasonography is the imaging technique of choice. Plain-film X-ray examination has been relegated to the initial management of renal colic, suspected foreign bodies, and intestinal obstruction. One of the drawbacks of MDCT is its use of ionizing radiation, which makes it necessary to filter and direct the examinations as well as to ensure that the most appropriate protocols are used. For this reason, low dose protocols have been developed so that diagnostic studies can be performed with doses of radiation between 2 and 3 mSv; these are normally used in the diagnosis of renal colic and can also be used in selected patients with suspected appendicitis and acute diverticulitis. PMID:21742357

  12. CHIMERA Multidetector at Laboratori Nazionali del Sud

    SciTech Connect

    Aiello, S.; Anzalone, A.; Baldo, M.; Barna, R.; Campisi, M.g.; Cardella, G.; Cavallaro, Sl., Amico, V.D.; De Filippo, E.; DePasquale, D.; Femino, S.; Geraci, E.; Giustolisi, F.; Guazzoni, P.; Iacono-Manno, C.M.; Italiano, A.; Lanzalone, G.; Lanzano, G.; LoNigro, S.; Lombardo, U.; Manfredi, G.; Pagano, A.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Sambataro, S.; Sperduto, M.L.; Sutera, C.M.; Zetta, L.

    2000-12-31

    The installation of CHIMERA multidetector, designed in order to study central collisions in heavy ion reactions at intermediate energy, is going on at LNS and the first experiment with the forward part (688 telescopes) is running since May 1999. The aim of this contribution is to present the status of the project.

  13. Analytical Computation of Effective Grid Parameters for the Finite-Difference Seismic Waveform Modeling With the PREM, IASP91, SP6, and AK135

    NASA Astrophysics Data System (ADS)

    Toyokuni, G.; Takenaka, H.

    2007-12-01

    We propose a method to obtain effective grid parameters for the finite-difference (FD) method with standard Earth models using analytical ways. In spite of the broad use of the heterogeneous FD formulation for seismic waveform modeling, accurate treatment of material discontinuities inside the grid cells has been a serious problem for many years. One possible way to solve this problem is to introduce effective grid elastic moduli and densities (effective parameters) calculated by the volume harmonic averaging of elastic moduli and volume arithmetic averaging of density in grid cells. This scheme enables us to put a material discontinuity into an arbitrary position in the spatial grids. Most of the methods used for synthetic seismogram calculation today receives the blessing of the standard Earth models, such as the PREM, IASP91, SP6, and AK135, represented as functions of normalized radius. For the FD computation of seismic waveform with such models, we first need accurate treatment of material discontinuities in radius. This study provides a numerical scheme for analytical calculations of the effective parameters for an arbitrary spatial grids in radial direction as to these major four standard Earth models making the best use of their functional features. This scheme can analytically obtain the integral volume averages through partial fraction decompositions (PFDs) and integral formulae. We have developed a FORTRAN subroutine to perform the computations, which is opened to utilization in a large variety of FD schemes ranging from 1-D to 3-D, with conventional- and staggered-grids. In the presentation, we show some numerical examples displaying the accuracy of the FD synthetics simulated with the analytical effective parameters.

  14. Heterogeneous Microinfarcts Caused by Coronary Microemboli: Evaluation with Multidetector CT and MR Imaging in a Swine Model1

    PubMed Central

    Saloner, David; Martin, Alastair J.; Ursell, Philip C.; Saeed, Maythem

    2010-01-01

    Purpose: To directly compare the sensitivity of 64-section multidetector computed tomography (CT) with that of 1.5-T magnetic resonance (MR) imaging in the depiction and measurement of heterogeneous 7–8-week-old microinfarcts and the quantification of regional left ventricular (LV) function and perfusion in the territory of coronary intervention in a swine model. Materials and Methods: Approval was obtained from the institutional animal committee. An x-ray/MR system was used to catheterize the left anterior descending (LAD) coronary artery with x-ray guidance and to delineate the perfusion territory. The vessel was selectively microembolized in six pigs with small-diameter embolic material (40–120 µm, 250000 count). At 7–8 weeks after microembolization, multidetector CT and MR imaging were used to assess LV function, first-pass perfusion, and delayed contrast enhancement in remote myocardium and microinfarct scars. Histochemical staining with triphenyltetrazolium chloride (TTC) was used to confirm and quantify heterogeneous microinfarct scars. The two-tailed Wilcoxon signed rank test was used to detect differences between modalities and myocardial regions. Results: The LAD territory was 32.4% ± 3.8(stadard error of the mean) of the LV mass. Multidetector CT and MR imaging have similar sensitivity in the detection of regional and global LV dysfunction and extent of microinfarct. The mean LV end-diastolic volume, end-systolic volume, and ejection fraction were 93 mL ± 8, 46 mL ± 4, and 50% ± 3, respectively, on multidetector CT images and 92 mL ± 8, 48 mL ± 5, and 48% ± 3, respectively, on MR images (P ≥ .05). The extent of heterogeneous microinfarct was not significantly different between multidetector CT (6.3% ± 0.8 of the LV mass), MR imaging (6.6% ± 0.5 of the LV mass), and TTC staining (7.0% ± 0.6 of the LV mass). First-pass multidetector CT and MR imaging demonstrated significant regional differences (P < .05) in time to peak between the

  15. Misty mesentery: a pictorial review of multidetector-row CT findings.

    PubMed

    Filippone, A; Cianci, R; Di Fabio, F; Storto, M L

    2011-04-01

    The term "misty mesentery" indicates a pathological increase in mesenteric fat attenuation at computed tomography (CT). It is frequently observed on multidetector CT (MDCT) scans performed during daily clinical practice and may be caused by various pathological conditions, including oedema, inflammation, haemorrhage, neoplastic infiltration or sclerosing mesenteritis. In patients suffering from acute abdominal disease, misty mesentery may be considered a feature of the underlying disease. Otherwise, it may represent an incidental finding on MDCT performed for other reasons. This article describes the MDCT features of misty mesentery in different diseases in order to provide a rational approach to the differential diagnosis. PMID:21311992

  16. Important advances in technology and unique applications to cardiovascular computed tomography.

    PubMed

    Chaikriangkrai, Kongkiat; Choi, Su Yeon; Nabi, Faisal; Chang, Su Min

    2014-01-01

    For the past decade, multidetector cardiac computed tomography and its main application, coronary computed tomography angiography, have been established as a noninvasive technique for anatomical assessment of coronary arteries. This new era of coronary artery evaluation by coronary computed tomography angiography has arisen from the rapid advancement in computed tomography technology, which has led to massive diagnostic and prognostic clinical studies in various patient populations. This article gives a brief overview of current multidetector cardiac computed tomography systems, developing cardiac computed tomography technologies in both hardware and software fields, innovative radiation exposure reduction measures, multidetector cardiac computed tomography functional studies, and their newer clinical applications beyond coronary computed tomography angiography. PMID:25574342

  17. Multidetector CT of Mandibular Fractures, Reductions, and Complications: A Clinically Relevant Primer for the Radiologist.

    PubMed

    Dreizin, David; Nam, Arthur J; Tirada, Nikki; Levin, Martin D; Stein, Deborah M; Bodanapally, Uttam K; Mirvis, Stuart E; Munera, Felipe

    2016-01-01

    After the nasal bones, the mandible is the second most common site of facial fractures, and mandibular fractures frequently require open reduction. In the trauma injury setting, multidetector computed tomography (CT) has become the cornerstone imaging modality for determining the most appropriate treatment management, fixation method, and surgical approach. Multidetector CT is also used to assess the adequacy of the reduction and evaluate potential complications in the postoperative period. For successful restoration of the mandible's form and function, as well as management of posttraumatic and postoperative complications, reconstructive surgeons are required to have a detailed understanding of mandibular biomechanics, occlusion, and anatomy. To provide added value in the diagnosis, treatment planning, and follow-up of mandibular fractures, radiologists should be aware of these concepts. Knowledge of the techniques commonly used to achieve occlusal and anatomic reduction and of the rationale behind the range of available treatment options for different injury patterns-from isolated and nondisplaced fractures to multisite and comminuted fractures-also is essential. This article focuses on the use of multidetector CT for pre- and postoperative evaluation of mandibular fractures and outlines fundamental concepts of diagnosis and management-beginning with an explanation of common fracture patterns and their biomechanical underpinnings, and followed by a review of the common postoperative appearances of these fractures after semirigid and rigid fixation procedures. Specific considerations regarding fractures in different regions of the tooth-bearing and non-tooth-bearing mandible and the unique issues pertaining to the edentulous atrophic mandible are reviewed, and key features that distinguish major from minor complications are described. (©)RSNA, 2016. PMID:27618328

  18. Search for continuous gravitational waves: Metric of the multidetector F-statistic

    SciTech Connect

    Prix, Reinhard

    2007-01-15

    We develop a general formalism for the parameter-space metric of the multidetector F-statistic, which is a matched-filtering detection statistic for continuous gravitational waves. We find that there exists a whole family of F-statistic metrics, parametrized by the (unknown) amplitude parameters of the gravitational wave. The multidetector metric is shown to be expressible in terms of noise-weighted averages of single-detector contributions, which implies that the number of templates required to cover the parameter space does not scale with the number of detectors. Contrary to using a longer observation time, combining detectors of similar sensitivity is therefore the computationally cheapest way to improve the sensitivity of coherent wide-parameter searches for continuous gravitational waves. We explicitly compute the F-statistic metric family for signals from isolated spinning neutron stars, and we numerically evaluate the quality of different metric approximations in a Monte Carlo study. The metric predictions are tested against the measured mismatches and we identify regimes in which the local metric is no longer a good description of the parameter-space structure.

  19. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    SciTech Connect

    Wang, Xiaohua; Yuan, Huishu; Duan, Jianghui; Du, Yipeng; Shen, Ning; He, Bei

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  20. Value and Accuracy of Multidetector Computed Tomography in Obstructive Jaundice

    PubMed Central

    Mathew, Rishi Philip; Moorkath, Abdunnisar; Basti, Ram Shenoy; Suresh, Hadihally B.

    2016-01-01

    Summary Background Objective; To find out the role of MDCT in the evaluation of obstructive jaundice with respect to the cause and level of the obstruction, and its accuracy. To identify the advantages of MDCT with respect to other imaging modalities. To correlate MDCT findings with histopathology/surgical findings/Endoscopic Retrograde CholangioPancreatography (ERCP) findings as applicable. Material/Methods This was a prospective study conducted over a period of one year from August 2014 to August 2015. Data were collected from 50 patients with clinically suspected obstructive jaundice. CT findings were correlated with histopathology/surgical findings/ERCP findings as applicable. Results Among the 50 people studied, males and females were equal in number, and the majority belonged to the 41–60 year age group. The major cause for obstructive jaundice was choledocholithiasis. MDCT with reformatting techniques was very accurate in picking a mass as the cause for biliary obstruction and was able to differentiate a benign mass from a malignant one with high accuracy. There was 100% correlation between the CT diagnosis and the final diagnosis regarding the level and type of obstruction. MDCT was able to determine the cause of obstruction with an accuracy of 96%. Conclusions MDCT with good reformatting techniques has excellent accuracy in the evaluation of obstructive jaundice with regards to the level and cause of obstruction. PMID:27429673

  1. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  2. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  3. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  4. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  5. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  6. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  7. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  8. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  9. 46 CFR 7.170 - Alaska Peninsula, AK to Aleutian Islands, AK.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Alaska Peninsula, AK to Aleutian Islands, AK. 7.170... BOUNDARY LINES Alaska § 7.170 Alaska Peninsula, AK to Aleutian Islands, AK. (a) A line drawn from the southernmost extremity of Cape Kumlium to the westernmost extremity of Nakchamik Island; thence to...

  10. 46 CFR 7.165 - Kenai Peninsula, AK to Kodiak Island, AK.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Kenai Peninsula, AK to Kodiak Island, AK. 7.165 Section... BOUNDARY LINES Alaska § 7.165 Kenai Peninsula, AK to Kodiak Island, AK. (a) A line drawn from the southernmost extremity of Kenai Peninsula at longitude 151°44.0′ W. to East Amatuli Island Light; thence to...

  11. Cirsoid Aneurysm of Coronary Arteries Associated with Arterioventricular Fistula Evaluated by 64-Multidetector CT Coronary Angiography: Depiction of a Case

    SciTech Connect

    Marrone, Gianluca Mamone, Giuseppe; Milazzo, Mariapina; Caruso, Settimo; Baravoglia, Cesar Hernandez; Vitulo, Patrizio; Gridelli, Bruno; Luca, Angelo

    2009-05-15

    A female patient with severe pulmonary hypertension was admitted for lung transplant evaluation. As an incidental finding, the chest CT showed diffuse and dilated coronaries, not detected at previous echocardiography. A coronary CT angiography was then performed using a 64-multidetector computed tomography (MDCT) scanner to better evaluate the coronary tree. The images obtained after postprocessing demonstrated tremendously aneurysmatic and tortuous coronary arteries and the presence of a septal branch deepening into the myocardium and penetrating the right ventricle cavity, forming an abnormal arterioventricular fistula. A causal relation between the aneurysms and the fistula is suspected.

  12. Anomalous Morphology of an Ectopic Tooth in the Maxillary Sinus on Three-Dimensional Computed Tomography Images

    PubMed Central

    Lai, Yee-Tak Alta; Luk, Yiu Shiobhon; Fung, Kai-Hung

    2013-01-01

    We describe a case of an incidentally-diagnosed ectopic tooth showing anomalous morphology in the maxillary antrum, using three-dimensional reconstruction of computed tomography images of the tooth obtained by multi-detector computed tomography. PMID:23705035

  13. Scenes from the past: multidetector CT of Egyptian mummies of the Redpath Museum.

    PubMed

    Wade, Andrew D; Garvin, Gregory J; Hurnanen, Jaana H; Williams, Licd Lana; Lawson, Barbara; Nelson, Andrew J; Tampieri, Donatella

    2012-01-01

    As a nondestructive method of historical and anthropologic inquiry, imaging has played an important role in mummy studies over the past several decades. Recent technologic advances have made multidetector computed tomography (CT) an especially useful means for deepening the present understanding of ancient cultures by examining preserved human remains. In April 2011, three ancient Egyptian human mummies from the Redpath Museum of McGill University were examined with 320-section multidetector CT as part of the IMPACT Radiological Mummy Database project headquartered at the University of Western Ontario. Whole-body scanning was performed with a section thickness of 0.5 mm and a peak voltage of 120 kVp, and the raw CT datasets were postprocessed by using smooth body and high-resolution bone convolution filters. Two of the mummies were scanned at different energy levels (80 and 135 keV). The high-resolution CT scans revealed the details of mummification and allowed observations about the socioeconomic and health status of the human subjects based on both the mummification technique used and the appearance of the remains, particularly the bones and teeth. The paleopathologic information obtained from the scans confirmed some findings in studies performed in the same mummies in the late 19th and 20th centuries. The CT scans also demonstrated a high degree of variability in Egyptian mortuary practice, variability that is not generally recognized in the literature. Unusual features that were observed included a relatively uncommon retained heart in mummy RM2718, retained lungs in a mummy from which the heart had been extracted (RM2720), and a cartonnage plaque placed over the left abdomen of a mummy that had been eviscerated transperineally (RM2717). PMID:22787004

  14. Scenes from the past: multidetector CT of Egyptian mummies of the Redpath Museum.

    PubMed

    Wade, Andrew D; Garvin, Gregory J; Hurnanen, Jaana H; Williams, Licd Lana; Lawson, Barbara; Nelson, Andrew J; Tampieri, Donatella

    2012-01-01

    As a nondestructive method of historical and anthropologic inquiry, imaging has played an important role in mummy studies over the past several decades. Recent technologic advances have made multidetector computed tomography (CT) an especially useful means for deepening the present understanding of ancient cultures by examining preserved human remains. In April 2011, three ancient Egyptian human mummies from the Redpath Museum of McGill University were examined with 320-section multidetector CT as part of the IMPACT Radiological Mummy Database project headquartered at the University of Western Ontario. Whole-body scanning was performed with a section thickness of 0.5 mm and a peak voltage of 120 kVp, and the raw CT datasets were postprocessed by using smooth body and high-resolution bone convolution filters. Two of the mummies were scanned at different energy levels (80 and 135 keV). The high-resolution CT scans revealed the details of mummification and allowed observations about the socioeconomic and health status of the human subjects based on both the mummification technique used and the appearance of the remains, particularly the bones and teeth. The paleopathologic information obtained from the scans confirmed some findings in studies performed in the same mummies in the late 19th and 20th centuries. The CT scans also demonstrated a high degree of variability in Egyptian mortuary practice, variability that is not generally recognized in the literature. Unusual features that were observed included a relatively uncommon retained heart in mummy RM2718, retained lungs in a mummy from which the heart had been extracted (RM2720), and a cartonnage plaque placed over the left abdomen of a mummy that had been eviscerated transperineally (RM2717).

  15. 46 CFR 7.150 - Canadian (BC) and United States (AK) Borders to Cape Spencer, AK.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Canadian (BC) and United States (AK) Borders to Cape Spencer, AK. 7.150 Section 7.150 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.150 Canadian (BC) and United States (AK) Borders to...

  16. 46 CFR 7.150 - Canadian (BC) and United States (AK) Borders to Cape Spencer, AK.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Canadian (BC) and United States (AK) Borders to Cape Spencer, AK. 7.150 Section 7.150 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.150 Canadian (BC) and United States (AK) Borders to...

  17. 46 CFR 7.150 - Canadian (BC) and United States (AK) Borders to Cape Spencer, AK.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Canadian (BC) and United States (AK) Borders to Cape Spencer, AK. 7.150 Section 7.150 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.150 Canadian (BC) and United States (AK) Borders to...

  18. 46 CFR 7.150 - Canadian (BC) and United States (AK) Borders to Cape Spencer, AK.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Canadian (BC) and United States (AK) Borders to Cape Spencer, AK. 7.150 Section 7.150 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.150 Canadian (BC) and United States (AK) Borders to...

  19. 46 CFR 7.150 - Canadian (BC) and United States (AK) Borders to Cape Spencer, AK.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Canadian (BC) and United States (AK) Borders to Cape Spencer, AK. 7.150 Section 7.150 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.150 Canadian (BC) and United States (AK) Borders to...

  20. Cam-type deformities: Concepts, criteria, and multidetector CT features.

    PubMed

    Mellado, J M; Radi, N

    2015-01-01

    Interpreting imaging studies of a painful hip requires detailed knowledge of the regional anatomy. Some variants of the proximal femur, such as cam-type deformities, can course asymptomatically or cause femoroacetabular impingement. The principal numerical criterion for defining cam-type deformities, the alpha angle, has some limitations. In this article, we review the anatomic variants of the anterior aspect of the proximal femur, focusing on cam-type deformities. Using diagrams and multidetector CT images, we describe the parameters that are useful for characterizing these deformities in different imaging techniques. We also discuss the potential correspondence of imaging findings of cam-type deformities with the terms coined by anatomists and anthropologists to describe these phenomena. PMID:25660594

  1. Cam-type deformities: Concepts, criteria, and multidetector CT features.

    PubMed

    Mellado, J M; Radi, N

    2015-01-01

    Interpreting imaging studies of a painful hip requires detailed knowledge of the regional anatomy. Some variants of the proximal femur, such as cam-type deformities, can course asymptomatically or cause femoroacetabular impingement. The principal numerical criterion for defining cam-type deformities, the alpha angle, has some limitations. In this article, we review the anatomic variants of the anterior aspect of the proximal femur, focusing on cam-type deformities. Using diagrams and multidetector CT images, we describe the parameters that are useful for characterizing these deformities in different imaging techniques. We also discuss the potential correspondence of imaging findings of cam-type deformities with the terms coined by anatomists and anthropologists to describe these phenomena.

  2. Toroid cavity/coil NMR multi-detector

    SciTech Connect

    Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.

    2007-09-18

    An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.

  3. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations

    SciTech Connect

    Tzedakis, Antonis; Damilakis, John; Perisinakis, Kostas; Karantanas, Apostolos; Karabekios, Spiros; Gourtsoyiannis, Nicholas

    2007-04-15

    The purpose of this study was to evaluate the effect of z overscanning on normalized effective dose for pediatric patients undergoing multidetector-computed tomography (CT) examinations. Five commercially available mathematical anthropomorphic phantoms representing newborn, 1-, 5-, 10-, and 15-year-old patients and the Monte Carlo N-Particle (MCNP, version 4C2) radiation transport code were employed in the current study to simulate pediatric CT exposures. For all phantoms, axial and helical examinations at 120 kV tube voltage were simulated. Scans performed at 80 kV were also simulated. Sex-specific normalized effective doses were estimated for four standard CT examinations i.e., head-neck, chest, abdomen-pelvis, and trunk, for all pediatric phantoms. Data for both axial and helical mode acquisition were obtained. In the helical mode, z overscanning was taken into account. The validity of the Monte Carlo results was verified by comparison with dose data obtained using thermoluminescence dosimetry and a physical pediatric anthropomorphic phantom simulating a 10-year-old child. In all cases normalized effective dose values were found to increase with increasing z overscanning. The percentage differences in normalized data between axial and helical scans may reach 43%, 70%, 36%, and 26% for head-neck, chest, abdomen-pelvis, and trunk studies, respectively. Normalized data for female pediatric patients was in general higher compared to male patients for all ages, examined regions, and z overscanning values. For both male and female children, the normalized effective dose values were reduced as the age was increased. For the same typical exposure conditions, dose values decreased when lower tube voltage was used; for a 1-year-old child, for example, the effective dose was 3.8 times lower when 80 kV instead of 120 kV was used. Normalized data for the estimation of effective dose to pediatric patients undergoing standard axial and helical CT examinations on an

  4. Can 64-row computed tomography replace angiography after coronary bypass?

    PubMed

    Doi, Hirosato; Koshima, Ryuji; Suzuki, Masato; Takahashi, Ken; Yokoyama, Hiroichi; Yoshida, Naoya

    2008-12-01

    Multi-detector (64-row) computed tomography has become an alternative to coronary angiography to diagnose graft occlusion and stenosis after coronary artery bypass. We compared the power of evaluation of multi-detector computed tomography with that of conventional coronary angiography in 60 patients who underwent coronary artery bypass with 135 grafts and 210 graft anastomoses. The diagnostic power of multi-detector computed tomography for graft occlusion was: 100% (2/2) sensitivity, 98.5% (131/133) specificity, 50% (2/4) positive predictive value, and 100% (133/133) negative predictive value; there were no significant differences in rates of occlusion among the different types of graft. The diagnostic power of multi-detector computed tomography for stenosis of the graft anastomosis was: 100% (2/2) sensitivity, 95.1% (194/204) specificity, 16.6% (2/12) positive predictive value, and 100% (194/194) negative predictive value, with no significant differences among grafts. Multi-detector computed tomography permits evaluation of bypass grafts and is much less invasive for the patients. PMID:18984751

  5. Multidetector CT evaluation of airway stents: what the radiologist should know.

    PubMed

    Godoy, Myrna C B; Saldana, David A; Rao, Praveen P; Vlahos, Ioannis; Naidich, David P; Benveniste, Marcelo F; Erasmus, Jeremy J; Marom, Edith M; Ost, David

    2014-01-01

    Airway stents are increasingly used to treat symptomatic patients with obstructive tracheobronchial diseases who are not amenable to surgical resection or who have poor performance status, precluding them from resection. The most common conditions that are treated with tracheobronchial stents are primary lung cancer and metastatic disease. However, stents have also been used to treat patients with airway stenosis related to a variety of benign conditions, such as tracheobronchomalacia, relapsing polychondritis, postintubation tracheal stenosis, postoperative anastomotic stenosis, and granulomatous diseases. Additionally, airway stents can be used as a barrier method in the management of esophagorespiratory fistulas. Many types of stents are available from different manufacturers. Principally, they are classified as silicone; covered and uncovered metal; or hybrid, which are made of silicone and reinforced by metal rings. The advantages and disadvantages of each type of airway stent are carefully considered when choosing the most appropriate stent for each patient. Multidetector computed tomography plays an important role in determining the cause and assessing the location and extent of airway obstruction. Moreover, it is very accurate in its depiction of complications after airway stent placement.

  6. Multidetector CT in the evaluation of potential living donors for liver transplantation.

    PubMed

    Alonso-Torres, Ana; Fernández-Cuadrado, Jaime; Pinilla, Inmaculada; Parrón, Manuel; de Vicente, Emilio; López-Santamaría, Manuel

    2005-01-01

    Living donor liver transplantation is increasingly being used to help compensate for the increasing shortage of cadaveric liver grafts. However, the extreme variability of the hepatic vascular systems can impede this surgical procedure. Evaluation of potential living donors was conducted in which a two-detector-row computed tomographic (CT) scanner was used to obtain arterial phase and portal dominant phase images following the intravenous injection of contrast material, after which three-dimensional maximum-intensity-projection and volume-rendered images were created. The vascular anatomy was evaluated, with special attention given to the origin and course of the artery to segment IV and the presence of variants, especially those considered relative or absolute contraindications for donation, those requiring reconstruction, or those potentially altering the surgical approach. In addition, graft and remnant liver volumes were determined and the liver parenchyma evaluated. Multidetector CT is proving to be valuable in the evaluation of potential living liver donors, contributing to donor safety and providing comprehensive information about the hepatic vascular anatomy, the liver parenchyma, and graft and remnant liver volume. This information is critical in choosing the most suitable potential donor, in surgical planning, and in obtaining an optimal graft that maintains the balance between blood supply and venous drainage. PMID:16009821

  7. Benefits of contrast-enhanced multidetector row CT colonography for preoperative staging in colorectal cancer patients

    NASA Astrophysics Data System (ADS)

    Iinuma, Gen; Moriyama, Noriyuki; Satake, Mitso; Miyakawa, Kunihisa; Muramatsu, Yukio; Tateishi, Ukihide; Akasu, Takayuki; Otake, Yousuke; Fujii, Takahiro; Kobayashi, Toshiaki

    2003-05-01

    Recently, CT colonography has been recognized as an effective option for evaluating colorectal polyps in the USA. We have applied this technique to preoperative staging of colorectal cancer patients with a contrast-enhanced multi-detector row CT (MDCT). The use of manipulated multi-planar reconstruction (MPR) views in contrast-enhanced MDCT colonography proved advantageous for detecting lymph node metastases. Furthermore, 3-dimensional (3D) endoluminal images with Hansfield-transparency settings allowed vascular views of the colorectal wall for identification of invasive colorectal cancers. Using endoluminal images, increase in flow and pooling of blood related to angiogenesis of invasive cancer could be demonstrated, not only in the lymph nodes but also in the colorectal wall. Both MPR views and 3D endoluminal images can be acquired from the same 3D volumetric data generated by helical scanning in MDCT colonography, and both have great potential as modalities for computer-aided diagnosis (CAD) using blood flow information. Therefore the use of CAD can be expected to improve radiologists' diagnostic performance with regard to colorectal cancer.

  8. [Motion analysis of target in stereotactic radiotherapy of lung tumors using 320-row multidetector CT].

    PubMed

    Imae, Toshikazu; Haga, Akihiro; Nakagawa, Keiichi; Ino, Kenji; Tanaka, Kenichirou; Okano, Yukari; Sasaki, Katsutake; Saegusa, Shigeki; Shiraki, Takashi; Oritate, Takashi; Yano, Keiichi; Shinohara, Hiroyuki

    2011-01-01

    Multi-detector computed tomography (MDCT) has rapidly evolved and is increasingly used for treatment simulation of thoracic and abdominal radiotherapy. A 320-detector row CT scanner has recently become available that allows axial volumetric scanning of a 16-cm-long range in a patient without table movement. Current radiotherapy techniques require a generous margin around the presumed gross tumor volume (GTV) to account for uncertainties such as tumor motion and set up error. Motion analysis is useful to evaluate the internal margin of a moving target due to respiration and to improve therapeutic precision. The purpose of this study is to propose a method using phase-only correlation to automatically detect the target and to assess the motion of the target in numerical phantoms and patients. Free-breathing scans using 320-detector row CT were acquired for 4 patients with lung tumor(s). The proposed method was feasible for motion analysis of all numerical phantoms and patients. The results reproduced the facts that the motion of tumors in the patients varied in orbits during the respiratory cycle and exhibited hysteresis. The maximum distance between peak exhalation and inhalation increased as the tumors approached the diaphragm. The proposed method detected the three-dimensional position of the targets automatically and analyzed the trajectories. The tumor motion due to respiration differed by region and was greatest for the lower lobe. PMID:21471676

  9. Multidetector CT investigation of the mummy of Rosalia Lombardo (1918-1920).

    PubMed

    Panzer, Stephanie; Gill-Frerking, Heather; Rosendahl, Wilfried; Zink, Albert R; Piombino-Mascali, Dario

    2013-10-01

    Whole-body multidetector computed tomography (CT) was performed on the mummified corpse of two-year-old Rosalia Lombardo, an anthropogenic mummy displayed in the Capuchin Catacombs of Palermo, Sicily, Italy. Rosalia Lombardo reportedly died of bronchopneumonia in 1920 and was preserved by the embalmer and taxidermist Alfredo Salafia with a formaldehyde-based fluid. Rosalia Lombardo's body is still exhibited in the Capuchin Catacombs inside the original glass-topped coffin in which she was placed. Only her head is visible: the rest of her body is covered by a sheet. CT images of Rosalia's body within her coffin were of reduced quality because of distinct metal artifacts caused by the coffin itself. Nevertheless, a detailed radiological analysis was possible for most of the body. Analysis of the data from the CT examination revealed indicators for the historically-reported endovasal and intracavity treatment. Rosalia's entire body was preserved in a remarkable state. The exceptional preservation of her internal organs made it possible to consider a radiological diagnosis of pneumonia. For this study, CT was determined to be the ultimate method for investigation, since Rosalia's body had to be kept untouched in her sealed coffin for conservation purposes. The CT examination offered new insights into the current preservation status of the body, and the superior contrast of CT allowed detailed assessment of different tissues. Post-processing methods provided reconstructions on any desired plane, as well as three-dimensional reconstruction, for the best possible visualization and interpretation of the body.

  10. Relationship between indexed epicardial fat volume and coronary plaque volume assessed by cardiac multidetector CT.

    PubMed

    You, Seulgi; Sun, Joo Sung; Park, Seon Young; Baek, Yoolim; Kang, Doo Kyoung

    2016-07-01

    We explored whether baseline indexed epicardial fat volume (EFVi) and serial changes in EFVi were associated with increase in coronary plaque volume as assessed by multidetector computed tomography.We retrospectively reviewed 87 patients with coronary artery plaque, identified during either baseline or follow-up cardiac computed tomography (CT) examinations. Each plaque volume was measured in volumetric units using a semiautomatic software tool. EFVi was quantified by calculating the total volume of epicardial tissue of CT density -190 to -30 HU, indexed to the body surface area. Clinical cardiovascular risk factors were extracted by medical record review at the time of the cardiac CT examinations. The relationship between EFVi and coronary plaque volume was explored by regression analysis.Although the EFVi did not change significantly from baseline to the time of the follow-up CT (65.7 ± 21.8 vs 66.0 ± 21.8 cm/m, P = 0.620), the plaque volumes were increased significantly on the follow-up CT scans. The annual change in EFVi was not accompanied by a parallel change in coronary plaque volume (P = 0.096-0.500). On univariate analysis, smoking, hypercholesterolemia, 10-year coronary heart disease risk, obesity, and baseline EFVi predicted rapid increases in lipid-rich and fibrous plaque volumes. On multivariate analysis, baseline EFVi (odds ratio = 1.029, P = 0.016) was an independent predictor of a rapid increase in lipid-rich plaque volume.EFVi was shown to be an independent predictor of a rapid increase in lipid-rich plaque volume. However, changes in EFVi were not associated with parallel changes in coronary plaque volume.

  11. Computed tomographic angiography in tetralogy of Fallot.

    PubMed

    Kasar, Pankajkumar Ashok; Ravikumar, Radhakrishnan; Varghese, Roy; Kotecha, Monika; Vimala, Jesudian; Kumar, Raghavan Nair Suresh

    2011-10-01

    Echocardiography is often inadequate for imaging tetralogy of Fallot, prompting cineangiography. This study prospectively evaluated multidetector computed tomographic angiography for preoperative evaluation of tetralogy of Fallot in 112 consecutive patients. Forty-eight had nonconfluent or hypoplastic pulmonary arteries (mean z-score, -2; range, -11.1-0.13) permitting only palliative or no surgery; 64 had adequate pulmonary artery anatomy (mean z-score, 0.59; range, -2.53-3.4) allowing total repair. The surgical data of 50 patients who underwent total correction were compared with transthoracic echocardiography and multidetector computed tomographic angiography findings. Multidetector computed tomographic angiography tended to reveal unsuspected collaterals and coronary abnormalities besides outlining the right ventricular outflow tract and pulmonary artery branches. The branch pulmonary artery diameter z-score was the most important determinant of surgical strategy, with the worst figures being associated with no surgical options or palliative surgery, and the best figures leading to corrective surgery. The mean radiation dose was 3.45 mSv. Multidetector computed tomographic angiography is a powerful supplement to echocardiography in the preoperative evaluation of tetralogy of Fallot.

  12. New absorbed dose measurement with cylindrical water phantoms for multidetector CT

    NASA Astrophysics Data System (ADS)

    Ohno, Takeshi; Araki, Fujio; Onizuka, Ryota; Hioki, Kazunari; Tomiyama, Yuuki; Yamashita, Yusuke

    2015-06-01

    The aim of this study was to develop new dosimetry with cylindrical water phantoms for multidetector computed tomography (MDCT). The ionization measurement was performed with a Farmer ionization chamber at the center and four peripheral points in the body-type and head-type cylindrical water phantoms. The ionization was converted to the absorbed dose using a 60Co absorbed-dose-to-water calibration factor and Monte Carlo (MC) -calculated correction factors. The correction factors were calculated from MDCT (Brilliance iCT, 64-slice, Philips Electronics) modeled with GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. The spectrum of incident x-ray beams and the configuration of a bowtie filter for MDCT were determined so that calculated photon intensity attenuation curves for aluminum (Al) and calculated off-center ratio (OCR) profiles in air coincided with those measured. The MC-calculated doses were calibrated by the absorbed dose measured at the center in both cylindrical water phantoms. Calculated doses were compared with measured doses at four peripheral points and the center in the phantom for various beam pitches and beam collimations. The calibration factors and the uncertainty of the absorbed dose determined using this method were also compared with those obtained by CTDIair (CT dose index in air). Calculated Al half-value layers and OCRs in air were within 0.3% and 3% agreement with the measured values, respectively. Calculated doses at four peripheral points and the centers for various beam pitches and beam collimations were within 5% and 2% agreement with measured values, respectively. The MC-calibration factors by our method were 44-50% lower than values by CTDIair due to the overbeaming effect. However, the calibration factors for CTDIair agreed within 5% with those of our method after correction for the overbeaming effect. Our method makes it possible to directly measure the absorbed dose for MDCT and is more robust and accurate than the

  13. Multi-detector row CT scanning in Paleoanthropology at various tube current settings and scanning mode.

    PubMed

    Badawi-Fayad, J; Yazbeck, C; Balzeau, A; Nguyen, T H; Istoc, A; Grimaud-Hervé, D; Cabanis, E- A

    2005-12-01

    The purpose of this study was to determine the optimal tube current setting and scanning mode for hominid fossil skull scanning, using multi-detector row computed tomography (CT). Four fossil skulls (La Ferrassie 1, Abri Pataud 1, CroMagnon 2 and Cro-Magnon 3) were examined by using the CT scanner LightSpeed 16 (General Electric Medical Systems) with varying dose per section (160, 250, and 300 mAs) and scanning mode (helical and conventional). Image quality of two-dimensional (2D) multiplanar reconstructions, three-dimensional (3D) reconstructions and native images was assessed by four reviewers using a four-point grading scale. An ANOVA (analysis of variance) model was used to compare the mean score for each sequence and the overall mean score according to the levels of the scanning parameters. Compared with helical CT (mean score=12.03), the conventional technique showed sustained poor image quality (mean score=4.17). With the helical mode, we observed a better image quality at 300 mAs than at 160 in the 3D sequences (P=0.03). Whereas in native images, a reduction in the effective tube current induced no degradation in image quality (P=0.05). Our study suggests a standardized protocol for fossil scanning with a 16 x 0.625 detector configuration, a 10 mm beam collimation, a 0.562:1 acquisition mode, a 0.625/0.4 mm slice thickness/reconstruction interval, a pitch of 5.62, 120 kV and 300 mAs especially when a 3D study is required.

  14. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    SciTech Connect

    Flohr, T. G.; Stierstorfer, K.; Suess, C.; Schmidt, B.; Primak, A. N.; McCollough, C. H.

    2007-05-15

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution.

  15. Multi-detector row CT scanning in Paleoanthropology at various tube current settings and scanning mode.

    PubMed

    Badawi-Fayad, J; Yazbeck, C; Balzeau, A; Nguyen, T H; Istoc, A; Grimaud-Hervé, D; Cabanis, E- A

    2005-12-01

    The purpose of this study was to determine the optimal tube current setting and scanning mode for hominid fossil skull scanning, using multi-detector row computed tomography (CT). Four fossil skulls (La Ferrassie 1, Abri Pataud 1, CroMagnon 2 and Cro-Magnon 3) were examined by using the CT scanner LightSpeed 16 (General Electric Medical Systems) with varying dose per section (160, 250, and 300 mAs) and scanning mode (helical and conventional). Image quality of two-dimensional (2D) multiplanar reconstructions, three-dimensional (3D) reconstructions and native images was assessed by four reviewers using a four-point grading scale. An ANOVA (analysis of variance) model was used to compare the mean score for each sequence and the overall mean score according to the levels of the scanning parameters. Compared with helical CT (mean score=12.03), the conventional technique showed sustained poor image quality (mean score=4.17). With the helical mode, we observed a better image quality at 300 mAs than at 160 in the 3D sequences (P=0.03). Whereas in native images, a reduction in the effective tube current induced no degradation in image quality (P=0.05). Our study suggests a standardized protocol for fossil scanning with a 16 x 0.625 detector configuration, a 10 mm beam collimation, a 0.562:1 acquisition mode, a 0.625/0.4 mm slice thickness/reconstruction interval, a pitch of 5.62, 120 kV and 300 mAs especially when a 3D study is required. PMID:16211320

  16. New absorbed dose measurement with cylindrical water phantoms for multidetector CT.

    PubMed

    Ohno, Takeshi; Araki, Fujio; Onizuka, Ryota; Hioki, Kazunari; Tomiyama, Yuuki; Yamashita, Yusuke

    2015-06-01

    The aim of this study was to develop new dosimetry with cylindrical water phantoms for multidetector computed tomography (MDCT). The ionization measurement was performed with a Farmer ionization chamber at the center and four peripheral points in the body-type and head-type cylindrical water phantoms. The ionization was converted to the absorbed dose using a (60)Co absorbed-dose-to-water calibration factor and Monte Carlo (MC) -calculated correction factors. The correction factors were calculated from MDCT (Brilliance iCT, 64-slice, Philips Electronics) modeled with GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. The spectrum of incident x-ray beams and the configuration of a bowtie filter for MDCT were determined so that calculated photon intensity attenuation curves for aluminum (Al) and calculated off-center ratio (OCR) profiles in air coincided with those measured. The MC-calculated doses were calibrated by the absorbed dose measured at the center in both cylindrical water phantoms. Calculated doses were compared with measured doses at four peripheral points and the center in the phantom for various beam pitches and beam collimations. The calibration factors and the uncertainty of the absorbed dose determined using this method were also compared with those obtained by CTDIair (CT dose index in air). Calculated Al half-value layers and OCRs in air were within 0.3% and 3% agreement with the measured values, respectively. Calculated doses at four peripheral points and the centers for various beam pitches and beam collimations were within 5% and 2% agreement with measured values, respectively. The MC-calibration factors by our method were 44-50% lower than values by CTDIair due to the overbeaming effect. However, the calibration factors for CTDIair agreed within 5% with those of our method after correction for the overbeaming effect. Our method makes it possible to directly measure the absorbed dose for MDCT and is more robust and accurate than the

  17. Study of statistical properties of hybrid statistic in coherent multidetector compact binary coalescences search

    NASA Astrophysics Data System (ADS)

    Haris, K.; Pai, Archana

    2016-05-01

    In this article, we revisit the coherent gravitational wave search problem of compact binary coalescences with multidetector network consisting of advanced interferometers like LIGO-Virgo. Based on the loss of the optimal multidetector signal-to-noise ratio (SNR), we construct a hybrid statistic as a best of maximum-likelihood-ratio (MLR) statistic tuned for face-on and face-off binaries. The statistical properties of the hybrid statistic is studied. The performance of this hybrid statistic is compared with that of the coherent MLR statistic for generic inclination angles. Owing to the single synthetic data stream, the hybrid statistic gives few false alarms compared to the multidetector MLR statistic and small fractional loss in the optimum SNR for a large range of binary inclinations. We demonstrate that, for a LIGO-Virgo network and binary inclination ɛ <7 0 ° and ɛ >11 0 ° , the hybrid statistic captures more than 98% of the network optimum matched filter SNR with a low false alarm rate. The Monte Carlo exercise with two distributions of incoming inclination angles—namely, U [cos ɛ ] and a more realistic distribution proposed by B. F. Schutz [Classical Quantum Gravity 28, 125023 (2011)]—are performed with the hybrid statistic and give approximately 5% and 7% higher detection probabilities, respectively, compared to the two stream multidetector MLR statistic for a fixed false alarm probability of 1 0-5.

  18. Lymph nodes metastasis of gastric cancer: Measurement with multidetector CT oblique multiplanar reformation-correlation with histopathologic results.

    PubMed

    Wang, Zhi-Long; Zhang, Xiao-Peng; Tang, Lei; Li, Xiao-Ting; Wu, Ying; Sun, Ying-Shi

    2016-09-01

    The aim of this study was to retrospectively evaluate the ability of multidetector computed tomography (MDCT) oblique multiplanar reformation (MPR) for differentiating metastatic lymph nodes (LNs) in patients with gastric cancer.Seventy-nine patients with gastric cancer underwent preoperative computed tomography (CT). One-to-one correlation of LN was made between CT oblique multiplanar reformation and histopathologic slides. Long diameters, short diameters, and short-to-long axis ratios of LNs were evaluated to differentiate metastasis.Short diameters of nodes performed better for diagnosing metastasis than long diameters and short-to-long ratios. Sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve of short diameter were 57.8%, 74.7%, 68.2%, and 0.713, respectively. With different thresholds of short diameters of nodes (No. 8 group >6 mm and other groups >4 mm), total sensitivity, specificity, and accuracy can reach 57.2%, 79.0%, and 70.3%, respectively.MDCT oblique MPR images have certain reference value to distinguish metastasis of LNs in gastric cancer. The diagnostic power for LN metastasis of gastric cancer can be improved by using different threshold for No. 8 group LNs and other groups. PMID:27684881

  19. Computed Tomography of Pancreatitis and Pancreatic Cancer.

    PubMed

    Furlow, Bryant

    2015-01-01

    Pancreatic disease often is asymptomatic until tissue damage and complications occur or until malignancies have reached advanced stages and have metastasized. Contrast-enhanced multidetector computed tomography plays a central role in diagnosing, staging, and treatment planning for pancreatitis and pancreatic cancer. This article introduces the functional anatomy of the pancreas and common bile duct and the epidemiology, pathobiology, and computed tomography imaging of pancreatitis, calculi, and pancreatic cancer.

  20. 77 FR 16314 - Alaska Disaster #AK-00024

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ... ADMINISTRATION Alaska Disaster AK-00024 AGENCY: U.S. Small Business Administration. ACTION: Notice. SUMMARY: This is a notice of an Administrative declaration of a disaster for the State of Alaska dated 03/13/2012... INFORMATION CONTACT: A. Escobar, Office of Disaster Assistance, U.S. Small Business Administration, 409...

  1. 78 FR 39822 - Alaska Disaster #AK-00028

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-02

    ... ADMINISTRATION Alaska Disaster AK-00028 AGENCY: U.S. Small Business Administration. ACTION: Notice SUMMARY: This is a Notice of the Presidential declaration of a major disaster for the State of Alaska (FEMA-4122-DR... INFORMATION CONTACT: A. Escobar, Office of Disaster Assistance, U.S. Small Business Administration, 409...

  2. 78 FR 39821 - Alaska Disaster #AK-00029

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-02

    ... ADMINISTRATION Alaska Disaster AK-00029 AGENCY: U.S. Small Business Administration. ACTION: Notice. SUMMARY: This is a Notice of the Presidential declaration of a major disaster for Public Assistance Only for the..., Fort Worth, TX 76155. FOR FURTHER INFORMATION CONTACT: A. Escobar, Office of Disaster Assistance,...

  3. 76 FR 35936 - Alaska Disaster #AK-00020

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-20

    ... From the Federal Register Online via the Government Publishing Office U.S. SMALL BUSINESS ADMINISTRATION Alaska Disaster AK-00020 AGENCY: U.S. Small Business Administration. ACTION: Notice. SUMMARY: This... completed loan applications to: U.S. Small Business Administration, Processing and Disbursement...

  4. Dual-energy CT revisited with multidetector CT: review of principles and clinical applications.

    PubMed

    Karçaaltıncaba, Muşturay; Aktaş, Aykut

    2011-09-01

    Although dual-energy CT (DECT) was first conceived in the 1970s, it was not widely used for CT indications. Recently, the simultaneous acquisition of volumetric dual-energy data has been introduced using multidetector CT (MDCT) with two X-ray tubes and rapid kVp switching (gemstone spectral imaging). Two major advantages of DECT are material decomposition by acquiring two image series with different kVp and the elimination of misregistration artifacts. Hounsfield unit measurements by DECT are not absolute and can change depending on the kVp used for an acquisition. Typically, a combination of 80/140 kVp is used for DECT, but for some applications, 100/140 kVp is preferred. In this study, we summarized the clinical applications of DECT and included images that were acquired using the dual-source CT and rapid kVp switching. In general, unenhanced images can be avoided by using DECT for body and neurological applications; iodine can be removed from the image, and a virtual, non-contrast (water) image can be obtained. Neuroradiological applications allow for the removal of bone and calcium from the carotid and brain CT angiography. Thorax applications include perfusion imaging in patients with pulmonary thromboemboli and other chest diseases, xenon ventilation-perfusion imaging and solitary nodule characterization. Cardiac applications include dual-energy cardiac perfusion, viability and cardiac iron detection. The removal of calcific plaques from arteries, bone removal and aortic stent graft evaluation may be achieved in the vascular system. Abdominal applications include the detection and characterization of liver and pancreas masses, the diagnosis of steatosis and iron overload, DECT colonoscopy and CT cholangiography. Urinary system applications are urinary calculi characterization (uric acid vs. non-uric acid), renal cyst characterization and mass characterization. Musculoskeletal applications permit the differentiation of gout from pseudogout and a reduction of

  5. Blind-ending branch of a bifid ureter: multidetector CT imaging findings

    PubMed Central

    Chang, E; Santillan, C; O'Boyle, M K

    2011-01-01

    A bifid ureter with a blind-ending branch is a rare congenital anomaly. Although typically found incidentally, this anomaly can be symptomatic and radiologists should be aware of this important variant. To our knowledge, there has been no previous report of this anomaly as seen on multidetector CT urography. We present a patient with haematuria and review the clinical significance, radiological findings and embryological aetiology of this anomaly. PMID:21257834

  6. Infrared multidetector spectrometer for remote sensing of temperature profiles in the presence of clouds.

    PubMed

    Aumann, H H; Chahine, M T

    1976-09-01

    An infrared multidetector spectrometer with channels in the 4.3-microm and 15-microm CO(2) bands for the remote sensing of temperature profiles in the presence of clouds is described. Results obtained from aircraft flights in July 1975 over ocean sites under various conditions of cloudiness demonstrate the capability of the dual frequency technique to recover surface temperatures to an accuracy of +/-0.5 K in the presence of up to 90% cloud cover.

  7. AkF ¯ chiral gauge theories

    NASA Astrophysics Data System (ADS)

    Shi, Yan-Liang; Shrock, Robert

    2015-11-01

    We study asymptotically free chiral gauge theories with an SU (N ) gauge group and chiral fermions transforming according to the antisymmetric rank-k tensor representation, Ak≡[k ]N , and the requisite number, nF ¯, of copies of fermions in the conjugate fundamental representation, F ¯ ≡[1] ¯ N , to render the theories anomaly-free. We denote these as AkF ¯ theories. We take N ≥2 k +1 so that nF ¯≥1 . The A2F ¯ theories form an infinite family with N ≥5 , but we show that the A3F ¯ and A4F ¯ theories are only asymptotically free for N in the respective ranges 7 ≤N ≤17 and 9 ≤N ≤11 , and that there are no asymptotically free AkF ¯ theories with k ≥5 . We investigate the types of ultraviolet to infrared evolution for these AkF ¯ theories and find that, depending on k and N , they may lead to a non-Abelian Coulomb phase, or may involve confinement with massless gauge-singlet composite fermions, bilinear fermion condensation with dynamical gauge and global symmetry breaking, or formation of multifermion condensates that preserve the gauge symmetry. We also show that there are no asymptotically free, anomaly-free SU (N ) SkF ¯ chiral gauge theories with k ≥3 , where Sk denotes the rank-k symmetric representation.

  8. Acute pulmonary embolism in the era of multi-detector CT: a reality in sub-Saharan Africa

    PubMed Central

    2012-01-01

    Background The advantages of multi-detector computed tomography (MDCT) have made it the imaging modality of choice for some patients with suspected cardiothoracic disease, of which pulmonary embolism (PE) is an exponent. The aim of this study was to assess the incidence of PE in patients with clinical suspicion of acute PE using MDCT in a sub-Saharan setting, and to describe the demographic characteristics of these patients. Methods Consecutive records of patients who underwent MDCT pulmonary angiography for suspected acute PE over a two-year period at the Radiology Department of a university-affiliated hospital were systematically reviewed. All MDCT pulmonary angiograms were performed with a 16-detector computed tomography (CT) scanner using real-time bolus tracking technique. Authorization for the study was obtained from the institutional authorities. Results Forty-one MDCT pulmonary angiograms were reviewed of which 37 were retained. Of the 4 excluded studies, 3 were repeat angiograms and 1 study was not technically adequate. Twelve of 37 patients (32.4%) had CT angiograms that were positive for PE, of which 7 were males. The mean age of these patients was 47.6±10.5 years (age range from 33 to 65 years). Twenty five patients out of 37 (67.6%) had CT angiograms that were negative for PE. Eleven PE-positive patients (91.7%) had at least 1 identifiable thromboembolic risk factor whilst 5 PE-negative patients (20%) also had at least a thromboembolic risk factor. The relative risk of the occurrence of PE in patients with at least a thromboembolic risk factor was estimated at 14.4. Conclusion Acute PE is a reality in sub-Saharan Africa, with an increased likelihood of MDCT evidence in patients with clinical suspicion of PE who have at least a thromboembolic risk factor. The increasing availability of MDCT will help provide more information on the occurrence of PE in these settings. PMID:23072500

  9. 40 CFR Appendixes A-K to Part 51 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false A Appendixes A-K to Part 51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Appendixes A-K to Part 51...

  10. 40 CFR Appendixes A-K to Part 51 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 2 2014-07-01 2014-07-01 false A Appendixes A-K to Part 51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Appendixes A-K to Part 51...

  11. 40 CFR Appendixes A-K to Part 51 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false A Appendixes A-K to Part 51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Appendixes A-K to Part 51...

  12. 40 CFR Appendixes A-K to Part 51 - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 2 2013-07-01 2013-07-01 false A Appendixes A-K to Part 51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Appendixes A-K to Part 51...

  13. 40 CFR Appendixes A-K to Part 51 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 2 2012-07-01 2012-07-01 false A Appendixes A-K to Part 51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Appendixes A-K to Part 51...

  14. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  15. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  16. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  17. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  18. 46 CFR 7.180 - Kotzebue Sound, AK.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Kotzebue Sound, AK. 7.180 Section 7.180 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC BOUNDARY LINES Alaska § 7.180 Kotzebue Sound, AK. A line drawn from Cape Espenberg Light to latitude 66°52′ N. longitude 163°28′ W.;...

  19. Cardiac Multidetector Computed Tomography: Basic Physics of Image Acquisition and Clinical Applications

    PubMed Central

    Bardo, Dianna M.E; Brown, Paul

    2008-01-01

    Cardiac MDCT is here to stay. And, it is more than just imaging coronary arteries. Understanding the differences in and the benefits of one CT scanner from another will help you to optimize the capabilities of the scanner, but requires a basic understanding of the MDCT imaging physics. This review provides key information needed to understand the differences in the types of MDCT scanners, from 64 – 320 detectors, flat panels, single and dual source configurations, step and shoot prospective and retrospective gating, and how each factor influences radiation dose, spatial and temporal resolution, and image noise. PMID:19936200

  20. Assessment of coronary bypass graft patency by first-line multi-detector computed tomography.

    PubMed

    Pesenti-Rossi, D; Baron, N; Georges, J-L; Augusto, S; Gibault-Genty, G; Livarek, B

    2014-11-01

    The purpose of the study was to assess whether a strategy based on a MDCT performed routinely before CA can reduce the radiation dose during the CA, without increased global exposure in patients who need imaging of CABG. A total of 147 consecutive patients were included. The radiation dose during CA (KAP 12.1 vs 22.0 Gy/cm(2), P<.01) and the volume of iodinated contrast (155 vs 200 mL, P<.02) were reduced when preceded by a MDCT. Patients' cumulative exposures were not different in the 2 strategies (5.0 vs 5.1 mSv, P=.76). MDCT performed in first line is a valuable strategy for the assessment of CABG. PMID:25258019

  1. Investigating the low-dose limits of multidetector CT in lung nodule surveillance.

    PubMed

    Paul, N S; Siewerdsen, J H; Patsios, D; Chung, T B

    2007-09-01

    The purpose of this study was to evaluate the factors limiting nodule detection in thoracic computed tomography (CT) and to determine whether prior knowledge of nodule size and attenuation, available from a baseline CT study, influences the minimum radiation dose at which nodule surveillance CT scans can be performed while maintaining current levels of nodule detectability. Multiple nodules varying in attenuation (-509 to + 110 HU) and diameter (1.6 to 9.5 mm) were layered in random and ordered sequences within 2 lung cylinders made of Rando lung material and suspended within a custom-built CT phantom. Multiple CT scans were performed at varying kVp (120, 100, and 80), mA (200, 150, 100, 50, 20, and 10), and beam collimation (5, 2.5, and 1.25 mm) on a four-row multidetector scanner (Lightspeed, General Electric, Milwaukee, WI) using 0.8 s gantry rotation. The corresponding range of radiation dose over which images were acquired was 0.3-26.4 mGy. Nine observers independently performed three specific tasks, namely: (1) To detect a 3.2 mm nodule of 23 HU; (2) To detect 3.2 mm nodules of varying attenuation (-509 to -154 HU); and (3) To detect nodules varying in size (1.6-9 mm) and attenuation (-509 to 110 HU). A two-alternative forced-choice test was used in order to determine the limits of nodule detection in terms of the proportion of correct responses (Pcorr, related to the area under the ROC curve) as a summary metric of observer performance. The radiation dose levels for detection of 99% of nodules in each task were as follows: Task 1 (1 mGy); Task 2 (5 mGy); and Task 3 (7 mGy). The corresponding interobserver confidence limits were 1, 5, and 10 mGy for Tasks 1, 2, and 3, respectively. There was a fivefold increase in the radiation dose required for detection of lower-density nodules (Tasks 1 to 2). Absence of prior knowledge of the nodule size and density (Task 3) corresponds to a significant increase in the minimum required radiation dose. Significant image

  2. Multi-Detector Coronary CT Imaging for the Identification of Coronary Artery Stenoses in a “Real-World” Population

    PubMed Central

    Makaryus, Amgad N; Henry, Sonia; Loewinger, Lee; Makaryus, John N; Boxt, Lawrence

    2014-01-01

    BACKGROUND Multi-detector computed tomography (CT) has emerged as a modality for the non-invasive assessment of coronary artery disease (CAD). Prior studies have selected patients for evaluation and have excluded many of the “real-world” patients commonly encountered in daily practice. We compared 64-detector-CT (64-CT) to conventional coronary angiography (CA) to investigate the accuracy of 64-CT in determining significant coronary stenoses in a “real-world” clinical population. METHODS A total of 1,818 consecutive patients referred for 64-CT were evaluated. CT angiography was performed using the GE LightSpeed VCT (GE® Healthcare). Forty-one patients in whom 64-CT results prompted CA investigation were further evaluated, and results of the two diagnostic modalities were compared. RESULTS A total of 164 coronary arteries and 410 coronary segments were evaluated in 41 patients (30 men, 11 women, age 39–85 years) who were identified by 64-CT to have significant coronary stenoses and who thereafter underwent CA. The overall per-vessel sensitivity, specificity, positive predictive value, negative predictive value, and accuracy at the 50% stenosis level were 86%, 84%, 65%, 95%, and 85%, respectively, and 77%, 93%, 61%, 97%, and 91%, respectively, in the per-segment analysis at the 50% stenosis level. CONCLUSION 64-CT is an accurate imaging tool that allows a non-invasive assessment of significant CAD with a high diagnostic accuracy in a “real-world” population of patients. The sensitivity and specificity that we noted are not as high as those in prior reports, but we evaluated a population of patients that is typically encountered in clinical practice and therefore see more “real-world” results. PMID:25628513

  3. Nonalcoholic Hepatic Steatosis Is a Strong Predictor of High-Risk Coronary-Artery Plaques as Determined by Multidetector CT

    PubMed Central

    Osawa, Kazuhiro; Miyoshi, Toru; Yamauchi, Kentarou; Koyama, Yasushi; Nakamura, Kazufumi; Sato, Shuhei; Kanazawa, Susumu; Ito, Hiroshi

    2015-01-01

    Background Nonalcoholic fatty liver disease is associated with a risk of coronary artery disease (e.g., diabetes mellitus, dyslipidemia, metabolic syndrome). We evaluated whether nonalcoholic hepatic steatosis is associated with high-risk plaques as assessed by multidetector computed tomography (CT). Methods This retrospective study involved 414 participants suspected of having coronary artery disease. Nonalcoholic hepatic steatosis was defined as a liver-to-spleen fat ratio of <1.0 and the presence and appropriate characteristics of coronary-artery plaques as assessed by coronary CT angiography. High-risk plaques were identified, as were low-density plaques, positive remodeling, and spotty calcification. Results Compared with patients who did not have nonalcoholic hepatic steatosis, patients with nonalcoholic hepatic steatosis had more low-density plaques (21% vs. 44%, p<0.01), positive remodeling (41% vs. 58%, p = 0.01), and spotty calcification (12% vs. 36%, p<0.01). The number of high-risk plaques in patients with nonalcoholic hepatic steatosis was greater than in those without nonalcoholic hepatic steatosis (p<0.01). Patients with nonalcoholic hepatic steatosis were more likely to have high-risk plaques than were those with only an elevated level of visceral adipose tissue (≥86 cm2; 35% vs. 16%, p<0.01). Multivariate analyses that included nonalcoholic hepatic steatosis, amount of visceral adipose tissue, and the presence/absence of traditional risk factors demonstrated that nonalcoholic hepatic steatosis was an independent predictor of high-risk plaques (odds ratio: 4.60; 95% confidence interval: 1.94–9.07, p<0.01). Conclusions Diagnosis of nonalcoholic hepatic steatosis may be of value when assessing the risk of coronary artery disease. PMID:26125952

  4. Comparison of Multidetector CT and Gadobutrol-Enhanced MR Imaging for Evaluation of Small, Solid Pancreatic Lesions

    PubMed Central

    Choi, Tae Won; Kim, Jung Hoon; Yu, Mi Hye; Han, Joon Koo; Choi, Byung Ihn

    2016-01-01

    Objective To compare multidetector computed tomography (MDCT) and MRI for lesion conspicuity, as well as the detection and characterization of small solid pancreatic lesions (SPLs). Materials and Methods 193 patients with small SPLs (< 3 cm) and 52 patients with normal pancreas who underwent both multiphasic MDCT and gadobutrol-enhanced MRI were included in our study. Two radiologists blinded to the pathologic diagnoses independently reviewed those images, and determined the detection of "SPL per se" and "SPL in consideration of secondary features", the lesion conspicuity, the probability of pancreatic ductal adenocarcinoma (PDAC), and the most likely specific diagnosis. Results The sensitivity of MRI for "detection of SPL per se" was significantly higher than that of CT in both reviewers: 92.7% (179/193) and 97.9% (189/193), respectively, for reviewer 1 (p = 0.031) and 90.7% (175/193) and 99.5% (192/193), respectively, for reviewer 2 (p < 0.001). In addition, MRI provided better lesion conspicuity than MDCT for both reviewers (p < 0.001). However, CT and MRI did not show significant difference in sensitivity for "detection of SPL in consideration of secondary features", specificity for SPL detection, and differentiation of PDAC vs. non-PDAC (p > 0.05). The accuracies of CT and MRI for making a specific diagnosis were as follows: 85.7% (210/245) vs. 86.9% (213/245), respectively, for reviewer 1 (p = 0.736), and 91.8% (225/245) vs. 93.5% (229/245), respectively, for reviewer 2 (p = 0.454). Conclusion MRI showed better lesion conspicuity than MDCT, but did not show significantly different diagnostic performance compared with MDCT for detecting and characterizing small SPLs. PMID:27390542

  5. Novel wearable and wireless ring-type pulse oximeter with multi-detectors.

    PubMed

    Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh

    2014-01-01

    The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.

  6. Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors

    PubMed Central

    Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh

    2014-01-01

    The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter. PMID:25244586

  7. 97. View of International Business Machine (IBM) digital computer model ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    97. View of International Business Machine (IBM) digital computer model 7090 magnetic core installation, international telephone and telegraph (ITT) Artic Services Inc., Official photograph BMEWS site II, Clear, AK, by unknown photographer, 17 September 1965, BMEWS, clear as negative no. A-6604. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  8. 98. View of IBM digital computer model 7090 magnet core ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    98. View of IBM digital computer model 7090 magnet core installation. ITT Artic Services, Inc., Official photograph BMEWS Site II, Clear, AK, by unknown photographer, 17 September 1965. BMEWS, clear as negative no. A-6606. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  9. Intercostal Artery Supplying Hepatocellular Carcinoma: Demonstration of a Tumor Feeder by C-arm CT and Multidetector Row CT

    SciTech Connect

    Kim, Hyo-Cheol Chung, Jin Wook; Lee, In Joon; An, Sangbu; Seong, Nak Jong; Son, Kyu Ri; Jae, Hwan Jun; Park, Jae Hyung

    2011-02-15

    This study was designed to describe tumor feeders from the intercostal artery supplying hepatocellular carcinoma (HCC) on C-arm CT and multidetector row CT. From March 2008 to May 2009, C-arm CT of the intercostal artery was prospectively performed in 24 HCC patients. Two interventional radiologists, who performed C-arm CT, evaluated tumor feeders on C-arm CT and multidetector row CT scans by consensus. In total, 35 intercostal arteries were examined by C-arm CT. All tumor feeders except one showed a sharp upward turn at or near the costochondral junction. On axial C-arm CT images, all tumor feeders were observed as an enhancing dot in the upper intercostal space along the diaphragm. On multidetector CT scans, 17 tumor feeders were observed and 18 were not. Tumor feeders from the intercostal artery are observed as an enhancing dot along the diaphragm on C-arm CT and can be seen on multidetector row CT in approximately half of patients.

  10. 75 FR 3641 - Television Broadcasting Services; Anchorage, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-22

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 73 Television Broadcasting Services; Anchorage, AK AGENCY: Federal Communications... broadcasting. 0 For the reasons discussed in the preamble, the Federal Communications Commission amends 47...

  11. 78 FR 55772 - Alaska Disaster Number AK-00028

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-11

    ... From the Federal Register Online via the Government Publishing Office ] SMALL BUSINESS ADMINISTRATION Alaska Disaster Number AK-00028 AGENCY: U.S. Small Business Administration. ACTION: Amendment 1... information in the original declaration remains unchanged. (Catalog of Federal Domestic Assistance...

  12. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    NASA Astrophysics Data System (ADS)

    Belinato, W.; Santos, W. S.; Paschoal, C. M. M.; Souza, D. N.

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current-time product (mAs) and pitch during PET/CT procedures.

  13. Genomic study of polyhydroxyalkanoates producing Aeromonas hydrophila 4AK4.

    PubMed

    Gao, Xue; Jian, Jia; Li, Wen-Jie; Yang, Yu-Cheng; Shen, Xiao-Wen; Sun, Zhi-Rong; Wu, Qiong; Chen, Guo-Qiang

    2013-10-01

    The complete genome of Gram-negative Aeromonas hydrophila 4AK4 that has been used for industrial production of poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) was sequenced and annotated. Its chromosome is 4,527,993 bp in size encoding 4,272 genes, including 28 rRNA genes and 104 tRNA genes. Comparative analysis indicated that genome of A. hydrophila 4AK4 was similar to that of the A. hydrophila ATCC 7966(T), an intensively studied aeromonad for its pathogenicity related to its genomic information. Genes possibly coming from other species or even other genus were identified in A. hydrophila 4AK4. A large number of putative virulent genes were predicted. However, a cytotonic enterotoxin (Ast) is absent in A. hydrophila 4AK4, allowing the industrial strain to be different from other A. hydrophila strains, indicating possible reduced virulence of strain 4AK4, which is very important for industrial fermentation. Genes involved in polyhydroxyalkanoate (PHA) metabolism were predicted and analyzed. The resulting genomic information is useful for improved production of PHA via metabolic engineering of A. hydrophila 4AK4.

  14. [Multidetector CT and magnetic resonance imaging features of solitary fibrous tumors in the pelvis and the relevant pathologic basis changes].

    PubMed

    Li, Xueming; Ren, Jing; Zhou, Peng; Cao, Ying; Cheng, Zhuzhong; Yu, Jianqun; Xu, Guohui

    2015-02-01

    In order to investigate the features of multidetector CT (MDCT) and magnetic resonance imaging (MRI) as well as the corresponding pathogic basis of solitary fibrous tumor (SFT) in the pelvis, we collected the clinical data of 13 patients with pathologically confirmed SFT in pelvis, and retrospectively reviewed the MDCT and MRI appearances. Of these enrolled patients, 6 received MDCT scans, 5 underwent MRI scans, and 2 underwent both MDCT and MRI examinations. Shown on the MDCT and MRI, the maximum diameters of the masses ranged from 4.0 to 25.2 cm (averaged 11.8 cm). Six masses were lobulated, and seven were round or oval. In addition, all masses were well-defined and displaced the adjacent structures to some degrees. On the computed tomography, all masses were of isodensity on unenhanced scans in general, among which five masses were demonstrated with hypodense areas. On the MRI T1-weighted image, all lesions were isointense, of which patchy hypointense areas were detected in 3 cases and radial hypointense areas were in 3 cases, and the other one was presented with homogenous intensity. On T2-weighted images, most of the lesions were mixed hyperintense, of which 3 cases were of heterogenous hyperintesity, radial hypointense areas were detected in 3 patients, and the other one was homogenously intense. On enhanced computed tomography and MRI, large supplying vessels were found in 4 cases; 12 cases showed moderate to conspicuous enhancement, and the other one was presented with mild homogenous enhancement. Of the patients with moderate to conspicuous enhancement, patchy areas of non-enhancement were detected in 7 cases, radial areas of progressive enhancement were detected in 3 cases, and the remained 2 cases showed homogenous enhancement. On pathology, the radial area presented as progressive enhancement was fibrosis. During the follow-ups after surgery, 2 patients had local recurrence and 1 had metastasis to liver. In conclusion, the SFT in the pelvis are commonly

  15. [Multidetector CT and magnetic resonance imaging features of solitary fibrous tumors in the pelvis and the relevant pathologic basis changes].

    PubMed

    Li, Xueming; Ren, Jing; Zhou, Peng; Cao, Ying; Cheng, Zhuzhong; Yu, Jianqun; Xu, Guohui

    2015-02-01

    In order to investigate the features of multidetector CT (MDCT) and magnetic resonance imaging (MRI) as well as the corresponding pathogic basis of solitary fibrous tumor (SFT) in the pelvis, we collected the clinical data of 13 patients with pathologically confirmed SFT in pelvis, and retrospectively reviewed the MDCT and MRI appearances. Of these enrolled patients, 6 received MDCT scans, 5 underwent MRI scans, and 2 underwent both MDCT and MRI examinations. Shown on the MDCT and MRI, the maximum diameters of the masses ranged from 4.0 to 25.2 cm (averaged 11.8 cm). Six masses were lobulated, and seven were round or oval. In addition, all masses were well-defined and displaced the adjacent structures to some degrees. On the computed tomography, all masses were of isodensity on unenhanced scans in general, among which five masses were demonstrated with hypodense areas. On the MRI T1-weighted image, all lesions were isointense, of which patchy hypointense areas were detected in 3 cases and radial hypointense areas were in 3 cases, and the other one was presented with homogenous intensity. On T2-weighted images, most of the lesions were mixed hyperintense, of which 3 cases were of heterogenous hyperintesity, radial hypointense areas were detected in 3 patients, and the other one was homogenously intense. On enhanced computed tomography and MRI, large supplying vessels were found in 4 cases; 12 cases showed moderate to conspicuous enhancement, and the other one was presented with mild homogenous enhancement. Of the patients with moderate to conspicuous enhancement, patchy areas of non-enhancement were detected in 7 cases, radial areas of progressive enhancement were detected in 3 cases, and the remained 2 cases showed homogenous enhancement. On pathology, the radial area presented as progressive enhancement was fibrosis. During the follow-ups after surgery, 2 patients had local recurrence and 1 had metastasis to liver. In conclusion, the SFT in the pelvis are commonly

  16. Revamping AK-Ashland gas cleaning system

    SciTech Connect

    Brandes, H.; Koerbel, R.; Haberkamp, K.; Keeton, S.

    1995-07-01

    AK Steel`s (formerly Armco) BOF shop was using a static precipitator for the primary collection. The system was designed for full combustion in the gas collecting hoods. No secondary dust collection was in place. A detailed study on alternative solutions led to a completely different system in 1990, and an order was awarded to Mannesmann Demag Corp. (MDC) in Dec. 1990. The new gas collection system is using suppressed combustion with the capability to collect Co at a later stage. The gas cleaning uses the Mannesmann Demag Baumco scrubber with a venturi throat for gas flow control. All auxiliary components, water treatment plant, electric substations and sludge handling were designed and supplied by MDC. The secondary dust collection covers the hot metal and scrap charging into the BOF`s, reladling, desulfurization and deslagging by a pulse jet baghouse. All emission limits set by the EPA and guaranteed by MDC have been met by the systems installed.

  17. High resolution multidetector CT aided tissue analysis and quantification of lung fibrosis

    NASA Astrophysics Data System (ADS)

    Zavaletta, Vanessa A.; Karwoski, Ronald A.; Bartholmai, Brian; Robb, Richard A.

    2006-03-01

    Idiopathic pulmonary fibrosis (IPF, also known as Idiopathic Usual Interstitial Pneumontis, pathologically) is a progressive diffuse lung disease which has a median survival rate of less than four years with a prevalence of 15-20/100,000 in the United States. Global function changes are measured by pulmonary function tests and the diagnosis and extent of pulmonary structural changes are typically assessed by acquiring two-dimensional high resolution CT (HRCT) images. The acquisition and analysis of volumetric high resolution Multi-Detector CT (MDCT) images with nearly isotropic pixels offers the potential to measure both lung function and structure. This paper presents a new approach to three dimensional lung image analysis and classification of normal and abnormal structures in lungs with IPF.

  18. Multidetector CT in emergency radiology: acute and generalized non-traumatic abdominal pain.

    PubMed

    Paolantonio, Pasquale; Rengo, Marco; Ferrari, Riccardo; Laghi, Andrea

    2016-01-01

    Multidetector CT (MDCT) is an imaging technique that provides otherwise unobtainable information in the diagnostic work-up of patients presenting with acute abdominal pain. A correct working diagnosis depends essentially on understanding the individual patient's clinical data and laboratory findings. In haemodynamically stable patients with acute severe and generalized abdominal pain, MDCT is now the preferred imaging test and gives invaluable diagnostic information, also in unstable patients after stabilization. In this descriptive review, we focus our attention on acute, severe and generalized or undifferentiated non-traumatic abdominal pain. The main differential diagnoses are acute pancreatitis, gastrointestinal perforation, ruptured abdominal aneurysm and acute mesenteric ischaemia. We will provide radiologist readers with a technical guide to optimize MDCT imaging protocols and list the major CT signs essential to reach a correct diagnosis and guide the best treatment. PMID:26689097

  19. Multidetector CT of expected findings and complications after contemporary inguinal hernia repair surgery

    PubMed Central

    Tonolini, Massimo

    2016-01-01

    Inguinal hernia repair (IHR) with prosthetic mesh implantation is the most common procedure in general surgery, and may be performed using either an open or laparoscopic approach. This paper provides an overview of contemporary tension-free IHR techniques and materials, and illustrates the expected postoperative imaging findings and iatrogenic injuries. Emphasis is placed on multidetector CT, which represents the ideal modality to comprehensively visualize the operated groin region and deeper intra-abdominal structures. CT consistently depicts seroma, mesh infections, hemorrhages, bowel complications and urinary bladder injuries, and thus generally provides a consistent basis for therapeutic choice. Since radiologists are increasingly requested to investigate suspected iatrogenic complications, this paper aims to provide an increased familiarity with early CT studies after IHR, including complications and normal postoperative appearances such as focal pseudolesions, in order to avoid misinterpretation and inappropriate management. PMID:27460285

  20. Pulmonary arterial hypertension: an imaging review comparing MR pulmonary angiography and perfusion with multidetector CT angiography

    PubMed Central

    Junqueira, F P; Lima, C M A O; Coutinho, A C; Parente, D B; Bittencourt, L K; Bessa, L G P; Domingues, R C; Marchiori, E

    2012-01-01

    Pulmonary hypertension (PH) is a progressive disease that leads to substantial morbidity and eventual death. Pulmonary multidetector CT angiography (MDCTA), pulmonary MR angiography (MRA) and MR-derived pulmonary perfusion (MRPP) imaging are non-invasive imaging techniques for the differential diagnosis of PH. MDCTA is considered the gold standard for the diagnosis of pulmonary embolism, one of the most common causes of PH. MRA and MRPP are promising techniques that do not require the use of ionising radiation or iodinated contrast material, and can be useful for patients for whom such material cannot be used. This review compares the imaging aspects of pulmonary MRA and 64-row MDCTA in patients with chronic thromboembolic or idiopathic PH. PMID:22932061

  1. Collimated prompt gamma TOF measurements with multi-slit multi-detector configurations

    NASA Astrophysics Data System (ADS)

    Krimmer, J.; Chevallier, M.; Constanzo, J.; Dauvergne, D.; De Rydt, M.; Dedes, G.; Freud, N.; Henriquet, P.; La Tessa, C.; Létang, J. M.; Pleskač, R.; Pinto, M.; Ray, C.; Reithinger, V.; Richard, M. H.; Rinaldi, I.; Roellinghoff, F.; Schuy, C.; Testa, E.; Testa, M.

    2015-01-01

    Longitudinal prompt-gamma ray profiles have been measured with a multi-slit multi-detector configuration at a 75 MeV/u 13C beam and with a PMMA target. Selections in time-of-flight and energy have been applied in order to discriminate prompt-gamma rays produced in the target from background events. The ion ranges which have been extracted from each individual detector module agree amongst each other and are consistent with theoretical expectations. In a separate dedicated experiment with 200 MeV/u 12C ions the fraction of inter-detector scattering has been determined to be on the 10%-level via a combination of experimental results and simulations. At the same experiment different collimator configurations have been tested and the shielding properties of tungsten and lead for prompt-gamma rays have been measured.

  2. [Multidetector row CT in assessment of coronary artery calcification on hemodialisis].

    PubMed

    Caro, P; Delgado, R; Dapena, F; Núñez, A

    2007-01-01

    Vascular calcification is a strong predictor of cardiovascular and all-cause mortality. Coronary artery calcification is more frequent, more extensive and progresses more rapidly in CKD than in general population. They are also considered a marker of coronary heart disease, with high prevalence and functional significance. It suggests that detection and surveillance may be worthwhile in general clinical practice. New non-invasive image techniques, like Multi-detector row CT, a type of spiral scanner, assess density and volume of calcification at multiple sites and allow quantitative scoring of vascular calcification using calcium scores analogous to those from electron-beam CT. We have assessed and quantified coronary artery calcification with 16 multidetector row CT in 44 patients on hemodialysis and their relationship with several cardiovascular risk factors. Coronary artery calcification prevalence was of 84 % with mean calcium score of 1580 +/- 2010 ( r 0-9844) with calcium score > 400 in 66% of patients. It was usually multiple, affecting more than two vessels in more than 50%. In all but one patient, left anterior descending artery was involved with higher calcium score level at right coronary artery. Advanced age, male, diabetes, smoking, more morbidity, cerebrovascular disease previous, and calcium-binders phosphate and analogous vitamin D treatment would seem to be associated with coronary artery calcification. Coronary artery calcification is very frequent and extensive, usually multiple and associated to modifiable risk factors in hemodialysis patients. Multi-detector-row CT seems an effective, suitable, readily applicable method to assess and quantify coronary artery calcification. PMID:18336102

  3. 78 FR 34609 - Proposed Modification of Class D and E Airspace; Kenai, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-10

    ... airspace, Class E surface airspace and Class E airspace designated as an extension to Class D surface area... surface area airspace excluded below 1,100 feet MSL beyond 4 miles from the airport would be decreased... Designated as Surface Areas. * * * * * ] AAL AK E2 Kenai, AK Kenai Municipal Airport, AK (Lat. 60 34'24''...

  4. Estimating radiation dose to organs of patients undergoing conventional and novel multidetector CT exams using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Angel, Erin

    Advances in Computed Tomography (CT) technology have led to an increase in the modality's diagnostic capabilities and therefore its utilization, which has in turn led to an increase in radiation exposure to the patient population. As a result, CT imaging currently constitutes approximately half of the collective exposure to ionizing radiation from medical procedures. In order to understand the radiation risk, it is necessary to estimate the radiation doses absorbed by patients undergoing CT imaging. The most widely accepted risk models are based on radiosensitive organ dose as opposed to whole body dose. In this research, radiosensitive organ dose was estimated using Monte Carlo based simulations incorporating detailed multidetector CT (MDCT) scanner models, specific scan protocols, and using patient models based on accurate patient anatomy and representing a range of patient sizes. Organ dose estimates were estimated for clinical MDCT exam protocols which pose a specific concern for radiosensitive organs or regions. These dose estimates include estimation of fetal dose for pregnant patients undergoing abdomen pelvis CT exams or undergoing exams to diagnose pulmonary embolism and venous thromboembolism. Breast and lung dose were estimated for patients undergoing coronary CTA imaging, conventional fixed tube current chest CT, and conventional tube current modulated (TCM) chest CT exams. The correlation of organ dose with patient size was quantified for pregnant patients undergoing abdomen/pelvis exams and for all breast and lung dose estimates presented. Novel dose reduction techniques were developed that incorporate organ location and are specifically designed to reduce close to radiosensitive organs during CT acquisition. A generalizable model was created for simulating conventional and novel attenuation-based TCM algorithms which can be used in simulations estimating organ dose for any patient model. The generalizable model is a significant contribution of this

  5. Characterizing string-of-pearls colloidal silica by multidetector hydrodynamic chromatography and comparison to multidetector size-exclusion chromatography, off-line multiangle static light scattering, and transmission electron microscopy.

    PubMed

    Brewer, Amandaa K; Striegel, André M

    2011-04-15

    The string-of-pearls-type morphology is ubiquitous, manifesting itself variously in proteins, vesicles, bacteria, synthetic polymers, and biopolymers. Characterizing the size and shape of analytes with such morphology, however, presents a challenge, due chiefly to the ease with which the "strings" can be broken during chromatographic analysis or to the paucity of information obtained from the benchmark microscopy and off-line light scattering methods. Here, we address this challenge with multidetector hydrodynamic chromatography (HDC), which has the ability to determine, simultaneously, the size, shape, and compactness and their distributions of string-of-pearls samples. We present the quadruple-detector HDC analysis of colloidal string-of-pearls silica, employing static multiangle and quasielastic light scattering, differential viscometry, and differential refractometry as detection methods. The multidetector approach shows a sample that is broadly polydisperse in both molar mass and size, with strings ranging from two to five particles, but which also contains a high concentration of single, unattached "pearls". Synergistic combination of the various size parameters obtained from the multiplicity of detectors employed shows that the strings with higher degrees of polymerization have a shape similar to the theory-predicted shape of a Gaussian random coil chain of nonoverlapping beads, while the strings with lower degrees of polymerization have a prolate ellipsoidal shape. The HDC technique is contrasted experimentally with multidetector size-exclusion chromatography, where, even under extremely gentle conditions, the strings still degraded during analysis. Such degradation is shown to be absent in HDC, as evidenced by the fact that the molar mass and radius of gyration obtained by HDC with multiangle static light scattering detection (HDC/MALS) compare quite favorably to those determined by off-line MALS analysis under otherwise identical conditions. The

  6. Characterizing string-of-pearls colloidal silica by multidetector hydrodynamic chromatography and comparison to multidetector size-exclusion chromatography, off-line multiangle static light scattering, and transmission electron microscopy.

    PubMed

    Brewer, Amandaa K; Striegel, André M

    2011-04-15

    The string-of-pearls-type morphology is ubiquitous, manifesting itself variously in proteins, vesicles, bacteria, synthetic polymers, and biopolymers. Characterizing the size and shape of analytes with such morphology, however, presents a challenge, due chiefly to the ease with which the "strings" can be broken during chromatographic analysis or to the paucity of information obtained from the benchmark microscopy and off-line light scattering methods. Here, we address this challenge with multidetector hydrodynamic chromatography (HDC), which has the ability to determine, simultaneously, the size, shape, and compactness and their distributions of string-of-pearls samples. We present the quadruple-detector HDC analysis of colloidal string-of-pearls silica, employing static multiangle and quasielastic light scattering, differential viscometry, and differential refractometry as detection methods. The multidetector approach shows a sample that is broadly polydisperse in both molar mass and size, with strings ranging from two to five particles, but which also contains a high concentration of single, unattached "pearls". Synergistic combination of the various size parameters obtained from the multiplicity of detectors employed shows that the strings with higher degrees of polymerization have a shape similar to the theory-predicted shape of a Gaussian random coil chain of nonoverlapping beads, while the strings with lower degrees of polymerization have a prolate ellipsoidal shape. The HDC technique is contrasted experimentally with multidetector size-exclusion chromatography, where, even under extremely gentle conditions, the strings still degraded during analysis. Such degradation is shown to be absent in HDC, as evidenced by the fact that the molar mass and radius of gyration obtained by HDC with multiangle static light scattering detection (HDC/MALS) compare quite favorably to those determined by off-line MALS analysis under otherwise identical conditions. The

  7. Advances in computed tomography imaging technology.

    PubMed

    Ginat, Daniel Thomas; Gupta, Rajiv

    2014-07-11

    Computed tomography (CT) is an essential tool in diagnostic imaging for evaluating many clinical conditions. In recent years, there have been several notable advances in CT technology that already have had or are expected to have a significant clinical impact, including extreme multidetector CT, iterative reconstruction algorithms, dual-energy CT, cone-beam CT, portable CT, and phase-contrast CT. These techniques and their clinical applications are reviewed and illustrated in this article. In addition, emerging technologies that address deficiencies in these modalities are discussed.

  8. F IASCO: a multidetector optimized for semiperipheral heavy ion collisions at Fermi energies

    NASA Astrophysics Data System (ADS)

    Bini, M.; Casini, G.; Olmi, A.; Poggi, G.; Stefanini, A. A.; Bardelli, L.; Bartoli, A.; Bidini, L.; Coppi, C.; Del Carmine, P.; Mangiarotti, A.; Maurenzig, P. R.; Pasquali, G.; Piantelli, S.; Poggi, S.; Taccetti, N.; Vanzi, E.

    2003-12-01

    The F IASCO multidetector is a low-threshold apparatus, optimized for the investigation of peripheral to semi-central collisions in heavy ion reactions at Fermi energies. It consists of three types of detectors. The first detector layer is a shell of 24 position-sensitive Parallel Plate Avalanche Detectors (PPADs), covering about 70% of the forward hemisphere, which measure the velocity vectors of the heavy ( Z≳10) reaction products. Below and around the grazing angle, behind the most forward PPADs, there are 96 Δ E-E silicon telescopes (with thickness of 200 and 500 μm, respectively); they are mainly used to measure the energy of the projectile-like fragment and to identify its charge and, via the time-of-flight of the PPADs, also its mass. Finally, behind most of the PPADs there are 158 (or 182, depending on the configuration) scintillation detectors, mostly of the phoswich type, which cover 25-30% of the forward hemisphere; they identify both light charged particles ( Z=1,2) and intermediate mass fragments (3⩽ Z≲20), measuring also their time-of-flight.

  9. Synthetic streams in a gravitational wave inspiral search with a multidetector network

    NASA Astrophysics Data System (ADS)

    Haris, K.; Pai, Archana

    2014-07-01

    A gravitational wave inspiral search with a global network of interferometers when carried in a phase coherent fashion mimics a search with two effective synthetic data streams. The streams are constructed by the linear combination of the overwhitened data from individual detectors. We demonstrate here that the two synthetic data streams pertaining to the two polarizations of the gravitational wave can be derived prior to the maximum-likelihood analysis in a most natural way using the technique of singular-value decomposition applied to the network signal-to-noise ratio vector. The singular-value technique combined with the matched filtering in network plus spectral space enables the construction of the synthetic streams. We further show that the network log likelihood ratio is then the sum of the log-likelihood ratios of these synthetic streams. In this formalism, the four extrinsic parameters of the nonspinning inspiral signal, namely, amplitude, initial phase, binary inclination, and the polarization {A0,ϕa,ɛ ,Ψ}, are mapped to the two amplitudes and two phases, namely, {ρL,ρR,ΦL,ΦR}. We show that the maximization over the new extrinsic parameters is a straightforward exercise closely linked to the single detector approach in the literature. Toward the end, we connect all the previous works related to the multidetector gravitational wave inspiral search and present in the same notation.

  10. [Characteristics of pneumoconiosis on multi-detector row CT and its' anatomic-pathologic basis].

    PubMed

    Feng, Yuanchun; Yang, Zhigang; Li, Yuan; Chen, Tianwu; Wang, Qiling; Deng, Wen

    2011-04-01

    In order to investigate the fine distinction of the tomographic images and the dominant anatomic distributions, we carefully reviewed and analyzed the features and predominant anatomic distribution of forty-nine pneumoconiosis patients with confirmed diagnosis on multi-detector row CT (MDCT). It was found that the round and small opacity p and irregular small opacity were mostly shown in the MDCT features of pneumoconiosis, while the large opacity and progressive massive fibrosis (PMF) were less frequently depicted in the MDCT. Distributions of round and small opacity and irregular small opacity in the six lung lobes were significantly different (P < 0.01). The most common p opacity was significantly seen in the upper and lower left lungs as well as in the upper right lung's opacity was in the upper left lung as well as lower left and right lungs. The large opacity commonly distributed in upper left and right lungs, while the PMF was often shown in both of two lungs. The results demonstrated that the MDCT could be an effective modality for detecting tiny lesions and anatomic distribution of pneumoconiosis, and it would be helpful for early diagnosis and accurate staging of the pneumoconiosis disease.

  11. 75 FR 62459 - Revision of Class E Airspace; Unalakleet, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... for air traffic management of Instrument Flight Rules (IFR) operations. DATES: Effective 0901 UTC... Federal Register to revise Class E airspace at Unalakleet, AK (75 FR 32865). Interested parties were... amendments to existing SIAPs require that the orientation and dimensions of Class E airspace be revised...

  12. 75 FR 76294 - Radio Broadcasting Services; Fairbanks, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-08

    ... COMMISSION 47 CFR Part 73 Radio Broadcasting Services; Fairbanks, AK AGENCY: Federal Communications... Review Act, see U.S.C. 801(a)(1)(A). List of Subjects in 47 CFR Part 73 Radio, Radio broadcasting. 0 For... follows: PART 73--RADIO BROADCAST SERVICES 0 1. The authority citation for Part 73 continues to read...

  13. 76 FR 8626 - Revision of Class E Airspace; Shungnak, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    ... U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71... airspace at Shungnak, AK (75 FR 77573). Interested parties were invited to participate in this rulemaking... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3)...

  14. Ak-Chin Indian Community Biomass Feasiiblity Study

    SciTech Connect

    Mark A. Moser, RCM Digesters, Inc.; Mark Randall, Daystar Consulting, LLC; Leonard S. Gold, Ak-Chin Energy Services & Utility Strategies Consulting Group

    2005-12-31

    Study of the conversion of chicken litter to biogas for the production of energy. There was an additional requirement that after extracting the energy from the chicken litter the nutrient value of the raw chicken litter had to be returned to the Ak-Chin Farms for use as fertilizer in a form and delivery method acceptable to the Farm.

  15. 78 FR 8962 - Establishment of Class E Airspace; Kasigluk, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-07

    ... airspace at Kasigluk, AK, to accommodate aircraft using Area Navigation (RNAV) Global Positioning System... FURTHER INFORMATION CONTACT: Richard Roberts, Federal Aviation Administration, Operations Support Group... INFORMATION: History On October 4, 2012, the FAA published in the Federal Register a notice of...

  16. 76 FR 75447 - Amendment of Class E Airspace; Emmonak, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-02

    ... Federal Register a notice of proposed rulemaking (NPRM) to amend controlled airspace at Emmonak, AK (76 FR... 12866; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034... FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The incorporation by reference in 14 CFR...

  17. 76 FR 43824 - Revision of Class E Airspace; Talkeetna, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-22

    ... revise Class E airspace at Talkeetna, AK (76 FR 27619). Interested parties were invited to participate in... U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71... not a ] ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February...

  18. 76 FR 43823 - Revision of Class E Airspace; Yakutat, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-22

    ... U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71... airspace to accommodate new SIAPS at Yakutat Airport, Yakutat, AK (76 FR 21832). Interested parties were... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3)...

  19. 76 FR 65944 - Establishment of Class E Airspace; Tatitlek, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-25

    ... to establish Class E airspace at Tatitlek, AK (76 FR 49388). Interested parties were invited to... U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71... not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February...

  20. 76 FR 66854 - Amendment of Class E Airspace; Nuiqsut, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-28

    ... rulemaking (NPRM) in the Federal Register to revise Class E airspace at Nuiqsut, AK (76 FR 49386). Interested..., 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The incorporation... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3)...

  1. 76 FR 66178 - Revision of Class E Airspace; Umiat, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-26

    ... proposed rulemaking (NPRM) in the Federal Register to revise Class E airspace at Umiat, AK (76 FR 49387... Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of a regulatory evaluation.... 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The incorporation by reference in...

  2. 78 FR 45849 - Amendment of Class E Airspace; Gustavus, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-30

    ... Register a notice of proposed rulemaking (NPRM) to amend controlled airspace at Gustavus, AK (78 FR 31871... 12866; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034...), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2....

  3. 78 FR 5128 - Amendment of Class E Airspace; Savoonga, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-24

    ... modify controlled airspace at Savoonga, AK (77 FR 61304). Interested parties were invited to participate... Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of... read as follows: Authority: 49 U.S.C. 106(g), 40103, 40113, 40120; E. O. 10854, 24 FR 9565, 3 CFR,...

  4. 78 FR 59622 - Establishment of Class E Airspace; Akutan, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-27

    ..., Akutan, AK (78 FR 45477). Interested parties were invited to participate in this rulemaking effort by... Executive Order 12866; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR...), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2....

  5. 78 FR 16399 - Amendment of Class E Airspace; Unalakleet, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-15

    ... (NPRM) to modify controlled airspace at Unalakleet, AK (77 FR 27149). Interested parties were invited to... Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of a... read as follows: Authority: 49 U.S.C. 106(g), 40103, 40113, 40120; E. O. 10854, 24 FR 9565, 3 CFR,...

  6. 76 FR 8627 - Revision of Class E Airspace; Platinum, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    ... Class E airspace at Platinum AK (75 FR 77572). Interested parties were invited to participate in this... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does... U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec....

  7. 76 FR 60714 - Revision of Class E Airspace; Northway, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... proposed rulemaking (NPRM) in the Federal Register to revise Class E airspace at Northway, AK (76 FR 45475...: Authority: 49 U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389...; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034;...

  8. 75 FR 12677 - Establishment of Class E Airspace; Shaktoolik, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ...-7587; telephone number (907) 271-5898; fax: (907) 271-2850; e-mail: gary.ctr.rolf@faa.gov . Internet.../rulemaking/ . SUPPLEMENTARY INFORMATION: History On Wednesday, December 16, 2009, the FAA published a notice of proposed rulemaking in the Federal Register to establish Class E airspace at Shaktoolik, AK (74...

  9. 75 FR 12676 - Establishment of Class E Airspace; Koyukuk, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ... number (907) 271-5898; fax: (907) 271-2850; e-mail: gary.ctr.rolf@faa.gov . Internet address: http://www.../ . SUPPLEMENTARY INFORMATION: History On Wednesday, December 16, 2009, the FAA published a notice of proposed rulemaking in the Federal Register to establish Class E airspace at Koyukuk, AK (74 FR 66594)....

  10. 75 FR 32269 - Revision of Class E Airspace; Wainwright, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... rulemaking in the Federal Register to revise Class E airspace at Wainwright, AK (75 FR 11480). Interested...; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February... FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The incorporation by reference in 14 CFR...

  11. 77 FR 6463 - Amendment of Class E Airspace; Kwigillingok, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ...;having general applicability and legal effect, most of which are keyed #0;to and codified in the Code of...-2011-0881 was published in the Federal Register (77 FR 6), amending controlled airspace at Kwigillingok Airport, AK. Subsequent to publication, an error was found in the latitude coordinate for...

  12. 75 FR 33165 - Revision of Class E Airspace; Galena, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-11

    ... FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The incorporation by reference in 14 CFR 71.1... airspace at Galena, AK (75 FR 17892). Interested parties were invited to participate in this rulemaking... Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of a regulatory...

  13. 77 FR 6 - Amendment of Class E Airspace; Kwigillingok, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    ... controlled airspace at Kwigillingok, AK (76 FR 54151). Interested parties were invited to participate in this... Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of... follows: Authority: 49 U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963...

  14. 78 FR 4586 - Environmental Impact Statement: Kake Access, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-22

    ... Federal Highway Administration Environmental Impact Statement: Kake Access, AK ACTION: Notice of intent... issuing this notice to advise the public that FHWA will prepare an Environmental Impact Statement (EIS... Meetings will be held in the early Spring of 2013 to receive oral and written comments on...

  15. 76 FR 8625 - Revision of Class E Airspace; Savoonga, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-15

    ... Federal Register to amend Class E airspace at Savoonga, AK (75 FR 77574). Interested parties were invited... Norton Sound Low Offshore Airspace Area and that airspace will be redefined in a future rulemaking action... not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February...

  16. 75 FR 32272 - Revision of Class E Airspace; Kaltag, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    .../headquarters_offices/ato/service_units/systemops/fs/alaskan/rulemaking/ . SUPPLEMENTARY INFORMATION: History On... revise Class E airspace at Kaltag, AK (75 FR 11479). Interested parties were invited to participate in... Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation...

  17. 76 FR 61258 - Revision of Class E Airspace; Allakaket, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-04

    ..._offices/ato/service_units/systemops/fs/alaskan/rulemaking/ . SUPPLEMENTARY INFORMATION: History On Friday... revise Class E airspace at Allakaket, AK (76 FR 45477). Interested parties were invited to participate in... not a ``significant rule'' under DOT ] Regulatory Policies and Procedures (44 FR 11034; February...

  18. 75 FR 62458 - Revision of Class E Airspace; Tanana, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    .../office_org/headquarters_offices/ato/service_units/systemops/fs/alaskan/rulemaking/ . SUPPLEMENTARY... Federal Register to revise Class E airspace at the Ralph M. Calhoun Memorial Airport, Tanana, AK (75 FR... not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February...

  19. 75 FR 32271 - Revision of Class E Airspace; Nenana, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... address: http://www.faa.gov/about/office_org/headquarters_offices/ato/service_units/systemops/fs/alaskan... proposed rulemaking in the Federal Register to revise Class E airspace at Nenana, AK (75 FR 11481... Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of a regulatory...

  20. Immunolocalization of arginine kinase (AK) in Toxocara canis, Toxocara vitulorum, and Ascaris lumbricoides.

    PubMed

    Kulathunga, D G R S; Wickramasinghe, Susiji; Rajapakse, R P V J; Yatawara, Lalani; Jayaweera, W R; Agatsuma, Takeshi

    2012-08-01

    Arginine kinase (AK) is a member of the phosphagen kinase family. AK plays a major role in cellular energy metabolism in invertebrates including nematodes. In the present study, we performed the direct immunofluorescence test to determine the immunolocalization of AK in different stages of the life cycle (eggs, larvae, and adult worms) of Toxocara canis, Toxocara vitulorum, and Ascaris lumbricoides. Our results indicated variable levels of expression of AK in different stages. Moreover, strong fluorescence was observed in cleaving eggs than in dormant eggs. The highest activity of the enzyme was observed in the fully developed eggs. This may be due to high expression of AK in embryonic development, which is associated with increased energy demand due to cleavage and cellular differentiation. Surprisingly, expression of AK is significantly higher in the middle part and posterior end compared to anterior end of the larvae. In addition, AK is highly concentrated in cellular and metabolically active parts of the body such as hypodermis, muscle, intestine, ovaries, oviducts, and uterus, while it is absent in noncellular areas like cuticle. The present study revealed the presence of AK in T. canis, A. lumbricoides, and T. vitulorum and that it plays a major role in energy metabolism of these nematodes. Interestingly, antiserum was prepared against the recombinant T. canis AK and reacts with the native AKs of T. canis, A. lumbricoides, and T. vitulorum. AK levels could vary in relation to maximum potential rates of ATP turnover, oxidative capacity, and energy output. Further studies on subcellular localization of AK in these important helminths provide new information for researchers to develop effective anthelmintics against the parasites of veterinary and of public health importance.

  1. H2A/K pseudogene mutation may promote cell proliferation.

    PubMed

    Guo, Jisheng; Jing, Ruirui; Lv, Xin; Wang, Xiaoyue; Li, Junqiang; Li, Lin; Li, Cuiling; Wang, Daoguang; Bi, Baibing; Chen, Xinjun; Yang, Jing-Hua

    2016-05-01

    Little attention has been paid to the histone H2A/K pseudogene. Results from our laboratory showed that 7 of 10 kidney cancer patients carried a mutant H2A/K pseudogene; therefore, we were interested in determining the relationship between mutant H2A/K and cell proliferation. We used shotgun and label-free proteomics methods to study whether mutant H2A/K lncRNAs affected cell proliferation. Quantitative proteomic analysis indicated that the expression of mutant H2A/K lncRNAs resulted in the upregulation of many oncogenes, which promoted cell proliferation. Further interaction analyses revealed that a proliferating cell nuclear antigen (PCNA)-protein interaction network, with PCNA in the center, contributes to cell proliferation in cells expressing the mutant H2A/K lncRNAs. Western blotting confirmed the critical upregulation of PCNA by mutant H2A/K lncRNA expression. Finally, the promotion of cell proliferation by mutant H2A/K lncRNAs (C290T, C228A and A45G) was confirmed using cell proliferation assays. Although we did not determine the exact mechanism by which the oncogenes were upregulated by the mutant H2A/K lncRNAs, we confirmed that the mutant H2A/K lncRNAs promoted cell proliferation by upregulating PCNA and other oncogenes. The hypothesis that cell proliferation is promoted by the mutant H2A/K lncRNAs was supported by the protein expression and cell proliferation assay results. Therefore, mutant H2A/K lncRNAs may be a new factor in renal carcinogenesis.

  2. Comparison of methods for assessing geometric efficiency on multi-detector CT scanners.

    PubMed

    Berris, Theocharis; Perisinakis, Kostas; Papadakis, Antonios E; Damilakis, John

    2013-05-01

    The aim of the current study was to compare the film method against the method based on a new CT slice detector in assessing geometric efficiency (GE) of x-ray beams utilized by a multi-detector CT (MDCT) scanner. Measurements of GE were performed using radiographic films and a solid state CT slice detector for all beam qualities, collimations and focal spot sizes available on an MDCT scanner. Repeatability of GE measurements was assessed. The radiographic film and the solid state detector methods were compared to each other in regard to efficacy in measuring free-in-air GE. The values of GE determined using the radiographic film method were found to range between 48.5% and 90.6%. Differences between values obtained with the radiographic film method and corresponding values obtained with the solid state detector were less than 10% exceeding 5% for only one case. Both methods show that wide beams have higher GE values compared to thin ones. The use of large instead of small focal spot was found to deteriorate GE values by up to 23.1%. Beam quality did not seem to influence GE of the various collimations. When thin beam collimations are employed, a considerable amount of the radiation is wasted for non-imaging purposes. Both film and solid state probe methods are capable of measuring GE of thin as well as wide collimations. The solid state detector is the easiest to use, however its usefulness is reduced by the fact that it cannot measure dose profiles of beam collimations available for step-and-shoot mode of operation.

  3. A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

    SciTech Connect

    Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas; Papadakis, Antonios E.

    2010-12-15

    Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made

  4. Multimodality treatment using AK-2123, hydralazine, radiation & hyperthermia on a transplantable mouse tumour.

    PubMed

    Rao, B S; Devi, P U

    1996-08-01

    The in vivo response of a transplantable mouse tumour, Sarcoma 180 to AK-2123 (AK), local irradiation (RT) and local hyperthermia, as influenced by a vasoactive drug, hydralazine (HDZ), was assessed on the basis of tumour cure (complete response CR), volume doubling time (VDT), regrowth delay (RD) and animal survival up to 120 days. A single ip injection of 200 mg/kg b.wt. AK produced more than 15 per cent CR. Combination of any two agents resulted in a better response than the single agent treatments. AK in combination with 43 degrees C, 30 min (HT) was more effective than HT combination with 10 Gy. The presence of 5 mg/kg HDZ, injected immediately after 5 Gy, in combination with AK increased the therapeutic effect over that produced by AK+10Gy. Combination of all the three agents (AK+10Gy+HT) produced 100 per cent CR and prolonged disease free animal survival. A similar response could be obtained by the presence of HDZ with a lower radiation dose of 5 Gy in combination with AK and HT (AK+5Gy+HDZ+HT). This multimodality treatment offers the possibility of further reduction in the doses of individual agents, and in the possible side effects on normal tissues without compromising the tumour cure effect.

  5. 77 FR 23269 - Determination That FUNDUSCEIN-25 (fluorescein sodium injection), 25%, and AK-FLUOR (fluorescein...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-18

    ... diagnostic fluorescein angiography or angioscopy of the retina and iris vasculature. AK-FLUOR (fluorescein... the retina and iris vasculature. FUNDUSCEIN-25 (fluorescein sodium injection), 25%, and...

  6. Recovery Act: Waste Energy Project at AK Steel Corporation Middletown

    SciTech Connect

    Joyce, Jeffrey

    2012-06-30

    In 2008, Air Products and Chemicals, Inc. (“Air Products”) began development of a project to beneficially utilize waste blast furnace “topgas” generated in the course of the iron-making process at AK Steel Corporation’s Middletown, Ohio works. In early 2010, Air Products was awarded DOE Assistance Agreement DE-EE002736 to further develop and build the combined-cycle power generation facility. In June 2012, Air Products and AK Steel Corporation terminated work when it was determined that the project would not be economically viable at that time nor in the foreseeable future. The project would have achieved the FOA-0000044 Statement of Project Objectives by demonstrating, at a commercial scale, the technology to capture, treat, and convert blast furnace topgas into electric power and thermal energy.

  7. An ancient Roman bowl embedded in a soil sample: surface shaded three dimensional display using data from a multi-detector CT.

    PubMed

    De Maeseneer, M; Buls, N; Cleeren, N; Lenchik, L; De Mey, J

    2006-01-01

    We present an unusual application of multidetector CT and shaded surface rendering in the investigation of a soil sample, containing an ancient Roman bronze bowl. The CT findings were of fundamental importance in helping the archaeologists study the bronze bowl from the soil sample.

  8. 39. View of checkout indicator computer console for DR beams, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. View of checkout indicator computer console for DR beams, TR chains, and special checkout target control located in CSMR in transmitter building no. 102. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  9. Multidetector CT Findings and Differential Diagnoses of Malignant Pleural Mesothelioma and Metastatic Pleural Diseases in Korea

    PubMed Central

    Kim, Yoon Kyung; Lee, Kyung Won; Yi, Chin A; Koo, Jin Mo; Jung, Soon-Hee

    2016-01-01

    Objective To compare the multidetector CT (MDCT) features of malignant pleural mesothelioma (MPM) and metastatic pleural disease (MPD). Materials and Methods The authors reviewed the MDCT images of 167 patients, 103 patients with MPM and 64 patients with MPD. All 167 cases were pathologically confirmed by sonography-guided needle biopsy of pleura, thoracoscopic pleural biopsy, or open thoracotomy. CT features were evaluated with respect to pleural effusion, pleural thickening, invasion of other organs, lung abnormality, lymphadenopathy, mediastinal shifting, thoracic volume decrease, asbestosis, and the presence of pleural plaque. Results Pleural thickening was the most common CT finding in MPM (96.1%) and MPD (93.8%). Circumferential pleural thickening (31.1% vs. 10.9%, odds ratio [OR] 3.670), thickening of fissural pleura (83.5% vs. 67.2%, OR 2.471), thickening of diaphragmatic pleura (90.3% vs. 73.4%, OR 3.364), pleural mass (38.8% vs. 23.4%, OR 2.074), pericardial involvement (56.3% vs. 20.3%, OR 5.056), and pleural plaque (66.0% vs. 21.9%, OR 6.939) were more frequently seen in MPM than in MPD. On the other hand, nodular pleural thickening (59.2% vs. 76.6%, OR 0.445), hilar lymph node metastasis (5.8% vs. 20.3%, OR 0.243), mediastinal lymph node metastasis (10.7% vs. 37.5%, OR 0.199), and hematogenous lung metastasis (9.7% vs. 29.2%, OR 0.261) were less frequent in MPM than in MPD. When we analyzed MPD from extrathoracic malignancy (EMPD) separately and compared them to MPM, circumferential pleural thickening, thickening of interlobar fissure, pericardial involvement and presence of pleural plaque were significant findings indicating MPM than EMPD. MPM had significantly lower occurrence of hematogenous lung metastasis, as compared with EMPD. Conclusion Awareness of frequent and infrequent CT findings could aid in distinguishing MPM from MPD. PMID:27390546

  10. Efficient Activation of Apoptotic Signaling during Mitotic Arrest with AK301

    PubMed Central

    Bleiler, Marina; Yeagley, Michelle; Wright, Dennis; Giardina, Charles

    2016-01-01

    Mitotic inhibitors are widely utilized chemotherapeutic agents that take advantage of mitotic defects in cancer cells. We have identified a novel class of piperazine-based mitotic inhibitors, of which AK301 is the most potent derivative identified to date (EC50 < 200 nM). Colon cancer cells arrested in mitosis with AK301 readily underwent a p53-dependent apoptosis following compound withdrawal and arrest release. This apoptotic response was significantly higher for AK301 than for other mitotic inhibitors tested (colchicine, vincristine, and BI 2536). AK301-treated cells exhibited a robust mitosis-associated DNA damage response, including ATM activation, γH2AX phosphorylation and p53 stabilization. The association between mitotic signaling and the DNA damage response was supported by the finding that Aurora B inhibition reduced the level of γH2AX staining. Confocal imaging of AK301-treated cells revealed multiple γ-tubulin microtubule organizing centers attached to microtubules, but with limited centrosome migration, raising the possibility that aberrant microtubule pulling may underlie DNA breakage. AK301 selectively targeted APC-mutant colonocytes and promoted TNF-induced apoptosis in p53-mutant colon cancer cells. Our findings indicate that AK301 induces a mitotic arrest state with a highly active DNA damage response. Together with a reversible arrest state, AK301 is a potent promoter of a mitosis-to-apoptosis transition that can target cancer cells with mitotic defects. PMID:27097159

  11. Reticular dysgenesis–associated AK2 protects hematopoietic stem and progenitor cell development from oxidative stress

    PubMed Central

    Rissone, Alberto; Weinacht, Katja Gabriele; la Marca, Giancarlo; Bishop, Kevin; Giocaliere, Elisa; Jagadeesh, Jayashree; Felgentreff, Kerstin; Dobbs, Kerry; Al-Herz, Waleed; Jones, Marypat; Chandrasekharappa, Settara; Kirby, Martha; Wincovitch, Stephen; Simon, Karen Lyn; Itan, Yuval; DeVine, Alex; Schlaeger, Thorsten; Schambach, Axel; Sood, Raman

    2015-01-01

    Adenylate kinases (AKs) are phosphotransferases that regulate the cellular adenine nucleotide composition and play a critical role in the energy homeostasis of all tissues. The AK2 isoenzyme is expressed in the mitochondrial intermembrane space and is mutated in reticular dysgenesis (RD), a rare form of severe combined immunodeficiency (SCID) in humans. RD is characterized by a maturation arrest in the myeloid and lymphoid lineages, leading to early onset, recurrent, and overwhelming infections. To gain insight into the pathophysiology of RD, we studied the effects of AK2 deficiency using the zebrafish model and induced pluripotent stem cells (iPSCs) derived from fibroblasts of an RD patient. In zebrafish, Ak2 deficiency affected hematopoietic stem and progenitor cell (HSPC) development with increased oxidative stress and apoptosis. AK2-deficient iPSCs recapitulated the characteristic myeloid maturation arrest at the promyelocyte stage and demonstrated an increased AMP/ADP ratio, indicative of an energy-depleted adenine nucleotide profile. Antioxidant treatment rescued the hematopoietic phenotypes in vivo in ak2 mutant zebrafish and restored differentiation of AK2-deficient iPSCs into mature granulocytes. Our results link hematopoietic cell fate in AK2 deficiency to cellular energy depletion and increased oxidative stress. This points to the potential use of antioxidants as a supportive therapeutic modality for patients with RD. PMID:26150473

  12. Absorbed Radiation Dose in Radiosensitive Organs Using 64- and 320-Row Multidetector Computed Tomography: A Comparative Study

    PubMed Central

    Khan, Atif N.; Nikolic, Boris; Khan, Mohammad K.; Kang, Jian; Khosa, Faisal

    2014-01-01

    Aim. To determine absorbed radiation dose (ARD) in radiosensitive organs during prospective and full phase dose modulation using ECG-gated MDCTA scanner under 64- and 320-row detector modes. Methods. Female phantom was used to measure organ radiation dose. Five DP-3 radiation detectors were used to measure ARD to lungs, breast, and thyroid using the Aquilion ONE scanner in 64- and 320-row modes using both prospective and dose modulation in full phase acquisition. Five measurements were made using three tube voltages: 100, 120, and 135 kVp at 400 mA at heart rate (HR) of 60 and 75 bpm for each protocol. Mean acquisition was recorded in milligrays (mGy). Results. Mean ARD was less for 320-row versus 64-row mode for each imaging protocol. Prospective EKG-gated imaging protocol resulted in a statistically lower ARD using 320-row versus 64-row modes for midbreast (6.728 versus 19.687 mGy, P < 0.001), lung (6.102 versus 21.841 mGy, P < 0.001), and thyroid gland (0.208 versus 0.913 mGy; P < 0.001). Retrospective imaging using 320- versus 64-row modes showed lower ARD for midbreast (10.839 versus 43.169 mGy, P < 0.001), lung (8.848 versus 47.877 mGy, P < 0.001), and thyroid gland (0.057 versus 2.091 mGy; P < 0.001). ARD reduction was observed at lower kVp and heart rate. Conclusions. Dose reduction to radiosensitive organs is achieved using 320-row compared to 64-row modes for both prospective and retrospective gating, whereas 64-row mode is equivalent to the same model 64-row MDCT scanner. PMID:25170427

  13. Association between Red Blood Cell Distribution Width and Coronary Artery Calcification in Patients Undergoing 64-Multidetector Computed Tomography

    PubMed Central

    Gürel, Ozgul Malcok; Bilgic, Mukadder Ayse; Yilmaz, Hakki; Yilmaz, Omer Caglar; Cakmak, Muzaffer; Eryonucu, Beyhan

    2015-01-01

    Background and Objectives The red blood cell distribution width (RDW) has been found to be associated with cardiovascular morbidity and mortality. The objective of this study was to determine whether the RDW measures are associated with the coronary artery calcification score (CACS) in patients who did not present with obvious coronary heart disease (CHD). Subjects and Methods A total of 527 consecutive patients with a low to intermediate risk for CHD but without obvious disease were enrolled in this study. The study subjects underwent coronary computerized tomography angiography and CACS was calculated. The patients were divided into two groups based on CACS: Group I (CACS≤100) and Group II (CACS>100). The two groups were compared in terms of classic CHD risk factors and haematological parameters, particularly the RDW. Results Group I patients were younger than Group II patients. The Framingham risk score (FRS) in patients of Group II was significantly higher than that in patients of Group I. Group II patients had significantly elevated levels of haemoglobin, RDW, neutrophil count, and neutrophil/lymphocyte ratio compared with Group I patients. CACS was correlated with age, RDW, and ejection fraction. In the multivariate analysis, age, RDW, and FRS were independent predictors of CACS. Using the receiver-operating characteristic curve analysis, a RDW value of 13.05% was identified as the best cut-off for predicting the severity of CACS (>100) (area under the curve=0.706). Conclusion We found that the RDW is an independent predictor of the CACS, suggesting that it might be a useful marker for predicting CAD. PMID:26413104

  14. Achieving consistent image quality with dose optimization in 64-row multidetector computed tomography prospective ECG gated coronary calcium scoring.

    PubMed

    Pan, Zilai; Pang, Lifang; Li, Jianying; Zhang, Huan; Yang, Wenjie; Ding, Bei; Chai, Weimin; Chen, Kemin; Yao, Weiwu

    2011-04-01

    To evaluate the clinical value of a body mass index (BMI) based tube current (mA) selection method for obtaining consistent image quality with dose optimization in MDCT prospective ECG gated coronary calcium scoring. A formula for selecting mA to achieve desired image quality based on patient BMI was established using a control group (A) of 200 MDCT cardiac patients with a standard scan protocol. One hundred patients in Group B were scanned with this BMI-dependent mA for achieving a desired noise level of 18 HU at 2.5 mm slice thickness. The CTDIvol and image noise on the ascending aorta for the two groups were recorded. Two experienced radiologists quantitatively evaluated the image quality using scores of 1-4 with 4 being the highest. The image quality scores had no statistical difference (P = 0.71) at 3.89 ± 0.32, 3.87 ± 0.34, respectively, for groups A and B of similar BMI. The image noise in Group A had linear relationship with BMI. The image noise in Group B using BMI-dependent mA was independent of BMI with average value of 17.9 HU and smaller deviations for the noise values than in Group A (2.0 vs. 2.9 HU). There was a 35% dose reduction with BMI-dependent mA selection method on average with the lowest effective dose being only 0.35 mSv for patient with BMI of 18.3. A quantitative BMI-based mA selection method in MDCT prospective ECG gated coronary calcium scoring has been proposed to obtain a desired and consistent image quality and provide dose optimization across patient population.

  15. Effect of reducing field of view on multi-detector quantitative computed tomography parameters of airway wall thickness in asthma

    PubMed Central

    Sheshadri, Ajay; Rodriguez, Alfonso; Chen, Ryan; Kozlowski, James; Burgdorf, Dana; Koch, Tammy; Tarsi, Jaime; Schutz, Rebecca; Wilson, Brad; Schechtman, Kenneth; Leader, Joseph K.; Hoffman, Eric A.; Castro, Mario; Fain, Sean B.; Gierada, David S.

    2015-01-01

    Objective We reduced the CT-reconstructed field of view (FOV), increasing pixel density across airway structures and reducing partial volume effects, to determine whether this would improve accuracy of airway wall thickness quantification. Methods We performed CT imaging on a lung phantom and 29 subjects. Images were reconstructed at 30, 15, and 10 cm FOV using a medium-smooth kernel. Cross-sectional airway dimensions were compared at each FOV with repeated-measures analysis of variance. Results Phantom measurements were more accurate when FOV decreased from 30 to 15 cm (p<0.05). Decreasing FOV further to 10 cm did not significantly improve accuracy. Human airway measurements similarly decreased by decreasing FOV (p<0.001). Percent changes in all measurements when reducing FOV from 30 to 15 cm were less than 3%. Conclusions Airway measurements at 30 cm FOV are near the limits of CT resolution using a medium-smooth kernel. Reducing reconstructed FOV would minimally increase sensitivity to detect differences in airway dimensions. PMID:25938213

  16. Some aspects of the effects of PL-10.1.AK-15 on the gastrointestinal tract.

    PubMed

    Erceg, D; Simicevic, V N; Kolega, M; Dohoczky, C

    1997-01-01

    PL-10.1.AK-15 is an active fragment of a naturally occurring protein first isolated from human gastric juice. Among its other protective effects, PL-10.1.AK-15 has demonstrated a protective effect on the gastrointestinal tract. The aim of this study was to investigate the influence of PL-10.1.AK-15 on two functional parameters of gastrointestinal function: gastric acid secretion and gastrointestinal motility. Gastric acid secretion was assessed in male Wistar rats using a modified method of Shay, while gastrointestinal motility was assessed in male NMRI mice by charcoal propulsion. PL-10.1.AK-15 was given in three different doses (3, 10 and 100 micrograms/kg body weight) in accordance with the experimental protocol. The results of these experiments indicate that PL-10.1.AK-15 in the investigated doses had no influence on gastric acid secretion or gastrointestinal motility. PMID:9403791

  17. Computed tomographic angiography in evaluation of superficial temporal to middle cerebral artery bypass.

    PubMed

    Besachio, David A; Ziegler, Jordan I; Duncan, Timothy D; Wanebo, John S

    2010-01-01

    Catheter-directed digital subtraction angiography (DSA) is considered the standard for evaluation of superficial temporal to middle cerebral artery (STA-MCA) bypass patency. Few clinical investigations have been performed that evaluate the efficacy of computed tomographic angiography (CTA) in the assessment of extracranial-intracranial bypass. Using multi-detector row CTA, STA-MCA bypass patency was assessed in the initial postoperative period and several months afterward and compared with DSA. No significant difference was identified in the evaluation of graft patency between DSA and CTA. Although multiple modalities exist to evaluate STA-MCA bypass graft patency, the multidetector CTA is widely available and allows for rapid, accurate patency assessment. PMID:20498550

  18. AK2 deficiency compromises the mitochondrial energy metabolism required for differentiation of human neutrophil and lymphoid lineages

    PubMed Central

    Six, E; Lagresle-Peyrou, C; Susini, S; De Chappedelaine, C; Sigrist, N; Sadek, H; Chouteau, M; Cagnard, N; Fontenay, M; Hermine, O; Chomienne, C; Reynier, P; Fischer, A; André-Schmutz, I; Gueguen, N; Cavazzana, M

    2015-01-01

    Reticular dysgenesis is a human severe combined immunodeficiency that is primarily characterized by profound neutropenia and lymphopenia. The condition is caused by mutations in the adenylate kinase 2 (AK2) gene, resulting in the loss of mitochondrial AK2 protein expression. AK2 regulates the homeostasis of mitochondrial adenine nucleotides (ADP, ATP and AMP) by catalyzing the transfer of high-energy phosphate. Our present results demonstrate that AK2-knocked-down progenitor cells have poor proliferative and survival capacities and are blocked in their differentiation toward lymphoid and granulocyte lineages. We also observed that AK2 deficiency impaired mitochondrial function in general and oxidative phosphorylation in particular – showing that AK2 is critical in the control of energy metabolism. Loss of AK2 disrupts this regulation and leads to a profound block in lymphoid and myeloid cell differentiation. PMID:26270350

  19. The role of multidetector-row CT in the diagnosis, classification and management of acute aortic syndrome

    PubMed Central

    Brown, I W; Peebles, C R; Harden, S P; Shambrook, J S

    2014-01-01

    The term “acute aortic syndrome” (AAS) encompasses several non-traumatic life-threatening pathologies of the thoracic aorta presenting in patients with a similar clinical profile. These include aortic dissection, intramural haematoma and penetrating atherosclerotic ulcers. These different pathological entities can be indistinguishable on clinical grounds alone and may be confused with other causes of chest pain, including myocardial infarction. Multidetector-row CT (MDCT) is the current modality of choice for imaging AAS with a sensitivity and specificity approaching 100%. Early diagnosis and accurate radiological classification is associated with improved clinical outcomes in AAS. We review the characteristic radiological features of the different pathologies that encompass AAS and highlight the vital role of MDCT in determining the management of these life-threatening conditions. PMID:25083552

  20. Unsuspected colorectal carcinoma on routine abdominopelvic computed tomography.

    PubMed

    Lee, Su Ann; Poh, Angeline

    2015-05-01

    Colorectal carcinoma is a common lethal disease with signs and symptoms that may be nonspecific. Computed tomography (CT) of the abdomen and pelvis with or without contrast is frequently performed for various general abdominal complaints, but unlike CT colonography, the large bowel may not be optimally prepared for evaluation. As such, careful and diligent assessment of the non-prepared colon in all CT images of the abdomen and pelvis is important, as it ensures that incidental colorectal malignancy is not missed, especially in older patients. This article gives an overview of multidetector CT imaging signs and subtle clues to aid in the diagnosis of colorectal carcinoma, as well as their pitfalls.

  1. A Photometric Study of the Misclassified Variable AK Ursae Minoris

    NASA Astrophysics Data System (ADS)

    Dale, H.; Sgro, L. A., Jr.

    2015-07-01

    The star AK UMi [GSC 4656-0461] was originally misidentified as an RRc-Lyrae pulsating variable by analyzing undersampled survey data. We used greater time resolved differential photometry to positively identify this variable as a W UMa overcontact (subtype A) binary system. The secondary minimum is a total eclipse, which enabled us to approximate the model for this system using some well-known characteristics of overcontact binaries. Our model solution parameters were found to be: i = 90˚, q = 0.21 (M2/M1), and T1 = 6750K, which indicated that the primary should be an F4.

  2. Multiforms of mammalian adenylate kinase and its monoclonal antibody against AK1.

    PubMed

    Kurokawa, Y; Takenaka, H; Sumida, M; Oka, K; Hamada, M; Kuby, S A

    1990-01-01

    An attempt has been made to determine the intracellular distribution of the multiforms of the adenylate kinase (AK) isoenzymes in mammalian tissues, to shed some light on their physiological roles, especially in energy metabolism. The adenylate kinase zymograms obtained from isoelectric focusing yielded two typical isoform patterns: (1) with a pI greater than or equal to 9 and 8.6, specific for bovine skeletal muscle, heart, aorta and brain, and (2) with a pI = 7.9 and 7.1, specific for liver and kidney. Pattern (1) was attributed to the cytosolic isoenzyme (AK1) as demonstrated by immunostaining with anti-AK1. Pattern (2) was attributed to the mitochondrial isoenzyme (AK2). These results were largely confirmed by chromatofocusing experiments. The AK1 isoenzyme was partially purified from the cytosol fraction of bovine aortic smooth muscle and had an apparent Mr of 23.5 kilodaltons. Its kinetic features are discussed from a comparative standpoint. Finally, the human serum AK1 isoform was also detected by Western blotting with a monoclonal antibody directed against crystalline porcine muscle AK1. These results are to form the basis of further studies on the 'aberrant' adenylate kinase isoenzyme from the serum of Duchenne muscular dystrophics.

  3. Genotypic Identification of Acanthamoeba sp. Isolates Associated with an Outbreak of Acanthamoeba keratitis (AK)

    PubMed Central

    Booton, Gregory C.; Joslin, Charlotte E.; Shoff, Megan; Tu, Elmer Y.; Kelly, Daryl J.; Fuerst, Paul A.

    2009-01-01

    Purpose Significant increases in Acanthamoeba keratitis (AK) cases have been observed in the Chicago-Gary-Kenosha area since June, 2003. It was hypothesized that increased rates of AK infections may be due to changes resulting from changes in municipal water treatment, or, alternatively, a more pathogenic strain of Acanthamoeba may be responsible. Methods Previous sequence analysis of the 18S rDNA of Acanthamoeba isolates resulted in the identification of 15 different genotypic classes. These analyses indicate AK cases are predominantly associated (~97%) with a single genotype (designated T4) of Acanthamoeba, and rarely with other genotypes (eg., T3 and T11). In this study we test the hypothesis that a new or more pathogenic genotype of Acanthamoeba is the cause of the recent surge in AK. Results We determined the genotype of 15 Acanthamoeba sp. isolates from AK cases from this outbreak using sequence analysis of a region of the 18S rDNA. Our results indicate that these isolates are predominantly genotype T4 (87%), with the remaining isolates being genotype T3 (13%). Both genotypes have previously been observed in AK cases. Conclusion There is no support for the hypothesis that the current AK outbreak is associated with infection by a new, more pathogenic, Acanthamoeba genotype. In addition, these results offer support for the hypothesis that the increased AK incidence may be due to changes in water treatment protocols leading to increased bacterial colonization of the water supply, and subsequent increases of already present Acanthamoeba sp, ultimately culminating in an increase of AK cases. PMID:19512903

  4. Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction

    SciTech Connect

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John

    2007-07-15

    The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary study on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM

  5. Improving Image Quality of On-Board Cone-Beam CT in Radiation Therapy Using Image Information Provided by Planning Multi-Detector CT: A Phantom Study

    PubMed Central

    Yang, Ching-Ching; Chen, Fong-Lin; Lo, Yeh-Chi

    2016-01-01

    Purpose The aim of this study was to improve the image quality of cone-beam computed tomography (CBCT) mounted on the gantry of a linear accelerator used in radiation therapy based on the image information provided by planning multi-detector CT (MDCT). Methods MDCT-based shading correction for CBCT and virtual monochromatic CT (VMCT) synthesized using the dual-energy method were performed. In VMCT, the high-energy data were obtained from CBCT, while the low-energy data were obtained from MDCT. An electron density phantom was used to investigate the efficacy of shading correction and VMCT on improving the target detectability, Hounsfield unit (HU) accuracy and variation, which were quantified by calculating the contrast-to-noise ratio (CNR), the percent difference (%Diff) and the standard deviation of the CT numbers for tissue equivalent background material, respectively. Treatment plan studies for a chest phantom were conducted to investigate the effects of image quality improvement on dose planning. Results For the electron density phantom, the mean value of CNR was 17.84, 26.78 and 34.31 in CBCT, shading-corrected CBCT and VMCT, respectively. The mean value of %Diff was 152.67%, 11.93% and 7.66% in CBCT, shading-corrected CBCT and VMCT, respectively. The standard deviation within a uniform background of CBCT, shading-corrected CBCT and VMCT was 85, 23 and 15 HU, respectively. With regards to the chest phantom, the monitor unit (MU) difference between the treatment plan calculated using MDCT and those based on CBCT, shading corrected CBCT and VMCT was 6.32%, 1.05% and 0.94%, respectively. Conclusions Enhancement of image quality in on-board CBCT can contribute to daily patient setup and adaptive dose delivery, thus enabling higher confidence in patient treatment accuracy in radiation therapy. Based on our results, VMCT has the highest image quality, followed by the shading corrected CBCT and the original CBCT. The research results presented in this study should be

  6. The Alaska Arctic Vegetation Archive (AVA-AK)

    DOE PAGES

    Walker, Donald; Breen, Amy; Druckenmiller, Lisa; Wirth, Lisa W.; Fisher, Will; Raynolds, Martha K.; Sibik, Jozef; Walker, Marilyn D.; Hennekens, Stephan; Boggs, Keith; et al

    2016-05-17

    The Alaska Arctic Vegetation Archive (AVA-AK, GIVD-ID: NA-US-014) is a free, publically available database archive of vegetation-plot data from the Arctic tundra region of northern Alaska. The archive currently contains 24 datasets with 3,026 non-overlapping plots. Of these, 74% have geolocation data with 25-m or better precision. Species cover data and header data are stored in a Turboveg database. A standardized Pan Arctic Species List provides a consistent nomenclature for vascular plants, bryophytes, and lichens in the archive. A web-based online Alaska Arctic Geoecological Atlas (AGA-AK) allows viewing and downloading the species data in a variety of formats, and providesmore » access to a wide variety of ancillary data. We conducted a preliminary cluster analysis of the first 16 datasets (1,613 plots) to examine how the spectrum of derived clusters is related to the suite of datasets, habitat types, and environmental gradients. Here, we present the contents of the archive, assess its strengths and weaknesses, and provide three supplementary files that include the data dictionary, a list of habitat types, an overview of the datasets, and details of the cluster analysis.« less

  7. 75 FR 5145 - AK Steel Corporation, Mansfield Works Division, Mansfield, OH; Notice of Affirmative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF LABOR Employment and Training Administration AK Steel Corporation, Mansfield Works Division, Mansfield, OH; Notice of Affirmative Determination Regarding Application for Reconsideration By application dated...

  8. Photometric analysis of overcontact binaries AK Her, HI Dra, V1128 Tau, and V2612 Oph

    SciTech Connect

    Çalışkan, Ş.; Özavcı, İ.; Baştürk, Ö.; Şenavcı, H. V.; Kılıçoğlu, T.; Yılmaz, M.; Selam, S. O.; Latković, O.; Djurašević, G.; Cséki, A. E-mail: ozavci@science.ankara.edu.tr E-mail: hvsenavci@ankara.edu.tr E-mail: mesutyilmaz@ankara.edu.tr E-mail: olivia@aob.rs E-mail: attila@aob.rs

    2014-12-01

    We analyze new, high quality multicolor light curves of four overcontact binaries: AK Her, HI Dra, V1128 Tau, and V2612 Oph, and determine their orbital and physical parameters using the modeling program of G. Djurasevic and recently published results of radial velocity studies. The achieved precision in absolute masses is between 10% and 20%, and the precision in absolute radii is between 5% and 10%. All four systems are W UMa-type binaries with bright or dark spots indicative of mass and energy transfer or surface activity. We estimate the distances and the ages of the systems using the luminosities computed through our analysis, and perform an O – C study for V1128 Tau, which reveals a complex period variation that can be interpreted in terms of mass loss/exchange and either the presence of the third body, or the magnetic activity on one of the components. We conclude that further observations of these systems are needed to deepen our understanding of their nature and variability.

  9. USP51 deubiquitylates H2AK13,15ub and regulates DNA damage response

    PubMed Central

    Wang, Zhiquan; Zhang, Honglian; Liu, Ji; Cheruiyot, Abigael; Lee, Jeong-Heon; Ordog, Tamas; Lou, Zhenkun; You, Zhongsheng; Zhang, Zhiguo

    2016-01-01

    Dynamic regulation of RNF168-mediated ubiquitylation of histone H2A Lys13,15 (H2AK13,15ub) at DNA double-strand breaks (DSBs) is crucial for preventing aberrant DNA repair and maintaining genome stability. However, it remains unclear which deubiquitylating enzyme (DUB) removes H2AK13,15ub. Here we show that USP51, a previously uncharacterized DUB, deubiquitylates H2AK13,15ub and regulates DNA damage response. USP51 depletion results in increased spontaneous DNA damage foci and elevated levels of H2AK15ub and impairs DNA damage response. USP51 overexpression suppresses the formation of ionizing radiation-induced 53BP1 and BRCA1 but not RNF168 foci, suggesting that USP51 functions downstream from RNF168 in DNA damage response. In vitro, USP51 binds to H2A–H2B directly and deubiquitylates H2AK13,15ub. In cells, USP51 is recruited to chromatin after DNA damage and regulates the dynamic assembly/disassembly of 53BP1 and BRCA1 foci. These results show that USP51 is the DUB for H2AK13,15ub and regulates DNA damage response. PMID:27083998

  10. Imaging of the heart with computed tomography.

    PubMed

    Flohr, Thomas G; Ohnesorge, Bernd M

    2008-03-01

    Imaging of the heart with computed tomography (CT) was already introduced in the 1980Is and has meanwhile entered clinical routine as a consequence of the rapid evolution of CT technology during the last decade. In this review article, we give an overview on the technology and clinical performance of different CT-scanner generations used for cardiac imaging, such as Electron Beam CT (EBCT), single-slice CT und multi-detector row CT (MDCT) with 4, 16 and 64 simultaneously acquired slices. We identify the limitations of current CT-scanners, indicate potential of improvement and discuss alternative system concepts such as CT with area detectors and dual source CT (DSCT). PMID:18324372

  11. Design and characterization of a compact multi-detector gamma spectrometer for studies of triggered energy release from nuclear isomers

    NASA Astrophysics Data System (ADS)

    Ugorowski, Philip; Propri, Ronald J.; Caldwell, Nathan; Lazich, Joseph; Carroll, James J.

    2004-10-01

    Nuclear Isomers are long-lived nuclear excited states, with lifetimes ranging up to decades or longer. Recently, attention has focused on the second isomeric state of 178-Hf (31-year natural half-life). The spontaneous decay takes the form of a cascade of gamma photons, totaling 2.45 MeV of energy per nucleus and corresponding to an energy density of 1.3 GigaJoules/gram. Since the ground state is stable, there is no radioactive residue and the 2.4 MeV therefore represents a ``clean'' release of energy. It has been suggested that isomers like this could be used for applications and that would require some means of causing an energy release upon demand. Thus, experiments have been performed to determine the cross-sections for x-ray induced decay, if it occurs. Positive indications by one group have been plagued by poor statistical accuracy in looking for triggered increases in the numbers of photons that correspond to the natural decay cascades. A refined technique based on calorimetry of gamma cascades has been devised to avoid these problems and a portable multi-detector array has been constructed for this purpose. This talk will discuss the design and characterization of this system.

  12. Computerized left ventricular regional ejection fraction analysis for detection of ischemic coronary artery disease with multidetector CT angiography.

    PubMed

    Zeb, Irfan; Li, Dong; Nasir, Khurram; Gupta, Mohit; Kadakia, Jigar; Gao, Yanlin; Ma, Eva; Mao, Song Shou; Budoff, Matthew

    2013-03-01

    Regional ejection fraction (REF) provides important functional information of the left ventricular regional myocardium. We aimed to test the diagnostic accuracy of computerized REF analysis for detecting the ischemia and significant stenosis with multidetector CT angiography (MDCT). This is a retrospective study including 155 patients who underwent MDCT scans for evaluation of coronary artery disease. Among them, 83 patients also underwent SPECT imaging and invasive coronary angiography (ICA). Two groups of patients were defined: Control group with 0 coronary artery calcium and normal global and regional ventricular function, and comparison group. REF measurement was performed on all patients using computerized software. Control group REF measurements will be used as reference standard (mean-2SD REF/mean global ejection fraction) to define abnormal REF. The sensitivity, specificity, positive and negative predictive value of REF in detecting perfusion defects (fixed and reversible) was 73, 80, 75 and 79 % respectively, in a patient based analysis of comparison group. The diagnostic accuracy of REF in predicting significant stenosis (>50 %) on ICA compared with SPECT was 72 versus 61 % and 85 versus 79 % in patient and vessel based analysis of comparison group, respectively. ROC curve analysis showed REF to be a better predictor of perfusion defects on SPECT compared with significant stenosis (>50 %) alone or stenosis combined with REF (P < 0.05). The computerized assessment of REF analysis is comparable to SPECT in predicting ischemia and a better predictor of significant stenosis than SPECT. This study also provides reference standard to define abnormal values.

  13. Evaluation of bone substitute materials: comparison of flat-panel based volume CT to conventional multidetector CT.

    PubMed

    Sauerbier, Sebastian; Duttenhoefer, Fabian; Sachlos, Elefterios; Haberstroh, Jörg; Scheifele, Christian; Wrbas, Karl-Thomas; Voss, Pit Jacob; Veigel, Egle; Smedek, Jörg; Ganter, Philip; Tuna, Taskin; Gutwald, Ralf; Palmowski, Moritz

    2013-10-01

    Over the last decade tissue engineering has emerged as a key factor in bone regeneration within the field of cranio-maxillofacial surgery. Despite this in vivo analysis of tissue-engineered-constructs to monitor bone rehabilitation are difficult to conduct. Novel high-resolving flat-panel based volume CTs (fp-VCT) are increasingly used for imaging bone structures. This study compares the potential value of novel fp-VCT with conventional multidetector CT (MDCT) based on a sheep sinus floor elevation model. Calcium-hydroxyapatite reinforced collagen scaffolds were populated with autologous osteoblasts and implanted into sheep maxillary sinus. After 8, 16 and 24 weeks MDCT and fp-VCT scans were performed to investigate the volume of the augmented area; densities of cancellous and compact bone were assessed as comparative values. fp-VCT imaging resulted in higher spatial resolution, which was advantageous when separating closely related anatomical structures (i.e. trabecular and compact bone, biomaterials). Fp-VCT facilitated imaging of alterations occurring in test specimens over time. fp-VCTs therefore displayed high volume coverage, dynamic imaging potential and superior performance when investigating superfine bone structures and bone remodelling of biomaterials. Thus, fp-VCTs may be a suitable instrument for intraoperative imaging and future in vivo tissue-engineering studies.

  14. Volume Changes of Experimental Carotid Sidewall Aneurysms Due to Embolization with Liquid Embolic Agents: A Multidetector CT Angiography Study

    SciTech Connect

    Dudeck, O. Okuducu, A. F.; Jordan, O.; Tesmer, K.; Pech, M.; Weigang, E.; Ruefenacht, D. A.; Doelker, E.; Felix, R.

    2006-12-15

    Iodine-containing polyvinyl alcohol polymer (I-PVAL) is a novel precipitating liquid embolic that allows for artifact-free evaluation of CT angiography (CTA). As accurate aneurysm volumetry can be performed with multidetector CTA, we determined volumes of experimental aneurysms before, immediately after, and 4 weeks after embolization of 14 porcine experimental carotid sidewall aneurysms with this liquid embolic. An automated three-dimensional software measurement tool was used for volumetric analysis of volume-rendering CTA data. Furthermore, intra-aneurysmal pressure changes during liquid embolization were measured in four silicone aneurysms and potential polymer volume changes within 4 weeks were assessed in vitro. Liquid embolic injection was performed during temporary balloon occlusion of the aneurysm neck, resulting in a mean occlusion rate of 98.3%. Aneurysms enlarged significantly during embolization by 61.1 {+-} 28.9%, whereas a significant shrinkage of 5.6 {+-} 2.7% was observed within the follow-up period. Histologic analysis revealed an inflammatory foreign body reaction with partial polymer degradation. In silicone aneurysm models, intra-aneurysmal pressure remained unchanged during liquid embolic injection, whereas balloon inflation resulted in a mean pressure increase of 31.2 {+-} 0.7%. No polymer shrinkage was observed in vitro. The aneurysm enlargement noted was presumably due to pressure elevation after balloon inflation, which resulted in dilatation of the weak venous wall of the newly constructed aneurysm-another shortcoming of this experimental aneurysm model. The volume decrease after 4 weeks expressed partial polymer degradation.

  15. Diagnostic capability of gadoxetate disodium-enhanced liver MRI for diagnosis of hepatocellular carcinoma: comparison with multi-detector CT.

    PubMed

    Toyota, Naoyuki; Nakamura, Yuko; Hieda, Masashi; Akiyama, Naoko; Terada, Hiroaki; Matsuura, Noriaki; Nishiki, Masayo; Kono, Hirotaka; Kohno, Hiroshi; Irei, Toshimitsu; Yoshikawa, Yukinobu; Kuraoka, Kazuya; Taniyama, Kiyomi; Awai, Kazuo

    2013-09-01

    The purpose of this study was to evaluate the diagnostic capability of gadoxetate disodium (Gd-EOB)-MRI for the detection of hepatocellular carcinoma (HCC) compared with multidetector CT (MDCT). Fifty patients with 57 surgically proven HCCs who underwent Gd-EOB-MRI and MDCT from March 2008 to June 2011 were evaluated. Two observers evaluated MR and CT on a lesion-by-lesion basis. We analyzed sensitivity by grading on a 5-point scale, the degree of arterial enhancement and the differences in histological grades in the diffusion-weighted images (DWI). The results showed that the sensitivity of Gd-EOB-MRI was higher than that of MDCT especially for HCCs that were 1 cm in diameter or smaller. The hepatobiliary phase was useful for the detecting of small HCC. We had few cases in which it was difficult to judge HCC in the arterial enhancement between MRI and MDCT. In the diffusion-weighted image, well differentiated HCC tended to show a low signal intensity, and poorly differentiated HCC tended to show a high signal intensity. In moderately differentiated HCC's, the mean diameter of the high signal intensity group was larger than that of the low signal intensity group (24.5 mm vs. 15.8 mm). In conclusion, Gd-EOB-MRI tended to show higher sensitivity compared to MDCT in the detection of HCC.

  16. [Computed tomography and cranial paleoanthropology].

    PubMed

    Cabanis, Emmanuel Alain; Badawi-Fayad, Jackie; Iba-Zizen, Marie-Thérèse; Istoc, Adrian; de Lumley, Henry; de Lumley, Marie-Antoinette; Coppens, Yves

    2007-06-01

    Since its invention in 1972, computed tomography (C.T.) has significantly evolved. With the advent of multi-slice detectors (500 times more sensitive than conventional radiography) and high-powered computer programs, medical applications have also improved. CT is now contributing to paleoanthropological research. Its non-destructive nature is the biggest advantage for studying fossil skulls. The second advantage is the possibility of image analysis, storage, and transmission. Potential disadvantages include the possible loss of files and the need to keep up with rapid technological advances. Our experience since the late 1970s, and a recent PhD thesis, led us to describe routine applications of this method. The main contributions of CT to cranial paleoanthropology are five-fold: --Numerical anatomy with rapid acquisition and high spatial resolution (helicoidal and multidetector CT) offering digital storage and stereolithography (3D printing). --Numerical biometry (2D and 3D) can be used to create "normograms" such as the 3D craniofacial reference model used in maxillofacial surgery. --Numerical analysis offers thorough characterization of the specimen and its state of conservation and/or restoration. --From "surrealism" to virtual imaging, anatomical structures can be reconstructed, providing access to hidden or dangerous zones. --The time dimension (4D imaging) confers movement and the possibility for endoscopic simulation and internal navigation (see Iconography). New technical developments will focus on data processing and networking. It remains our duty to deal respectfully with human fossils. PMID:18402165

  17. Cobalt-, zinc- and iron-bound forms of adenylate kinase (AK) from the sulfate-reducing bacterium Desulfovibrio gigas: purification, crystallization and preliminary X-ray diffraction analysis

    PubMed Central

    Kladova, A. V.; Gavel, O. Yu.; Mukhopaadhyay, A.; Boer, D. R.; Teixeira, S.; Shnyrov, V. L.; Moura, I.; Moura, J. J. G.; Romão, M. J.; Trincão, J.; Bursakov, S. A.

    2009-01-01

    Adenylate kinase (AK; ATP:AMP phosphotransferase; EC 2.7.4.3) is involved in the reversible transfer of the terminal phosphate group from ATP to AMP. AKs contribute to the maintenance of a constant level of cellular adenine nucleotides, which is necessary for the energetic metabolism of the cell. Three metal ions, cobalt, zinc and iron(II), have been reported to be present in AKs from some Gram-negative bacteria. Native zinc-containing AK from Desulfo­vibrio gigas was purified to homogeneity and crystallized. The crystals diffracted to beyond 1.8 Å resolution. Furthermore, cobalt- and iron-containing crystal forms of recombinant AK were also obtained and diffracted to 2.0 and 3.0 Å resolution, respectively. Zn2+–AK and Fe2+–AK crystallized in space group I222 with similar unit-cell parameters, whereas Co2+–AK crystallized in space group C2; a monomer was present in the asymmetric unit for both the Zn2+–AK and Fe2+–AK forms and a dimer was present for the Co2+–AK form. The structures of the three metal-bound forms of AK will provide new insights into the role and selectivity of the metal in these enzymes. PMID:19724135

  18. Complete Genome Sequence of Pontibacter akesuensis Strain AKS 1T, Which Exhibits Robust Nutrient Metabolism in Harsh Environments

    PubMed Central

    Wang, Yang; He, Kaiyong; Jiang, Yongzhong; Shen, Jiate

    2016-01-01

    Pontibacter akesuensis strain AKS 1T was found in Akesu, Xinjiang Province, China, and exhibits the extraordinary ability to metabolize various substrates and is resistant to solar radiation. To gain insight into the bacterial genetic determinants for this adaptability, we report the complete genome sequence of strain AKS 1T.

  19. 75 FR 9442 - AK Steel Corporation, Mansfield Works Division, Including On-Site Leased Workers From Time...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-02

    ... Employment and Training Administration TA-W-71,375 AK Steel Corporation, Mansfield Works Division, Including... impacted employment at AK Steel Corporation, Mansfield Works Division, Mansfield, Ohio. The survey of the... Corporation, Mansfield Works Division, including on-site leased workers from Time Customized...

  20. Pulmonary capillary hemangiomatosis: a focus on the EIF2AK4 mutation in onset and pathogenesis

    PubMed Central

    Ma, Lijiang; Bao, Ruijun

    2015-01-01

    Pulmonary capillary hemangiomatosis (PCH) is a pulmonary vascular disease that mainly affects small capillaries in the lung, and is often misdiagnosed as pulmonary arterial hypertension or pulmonary veno-occlusive disease due to similarities in their clinical presentations, prognosis, and management. In patients who are symptomatic, there is a high mortality rate with median survival of 3 years after diagnosis. Both idiopathic and familial PCH cases are being reported, indicating there is genetic component in disease etiology. Mutations in the eukaryotic translation initiation factor 2α kinase 4 (EIF2AK4) gene were identified in familial and idiopathic PCH cases, suggesting EIF2AK4 is a genetic risk factor for PCH. EIF2AK4 mutations were identified in 100% (6/6) of autosomal recessively inherited familial PCH and 20% (2/10) of sporadic PCH cases. EIF2AK4 is a member of serine/threonine kinases. It downregulates protein synthesis in response to a variety of cellular stress such as hypoxia, viral infection, and amino acid deprivation. Bone morphogenetic protein receptor 2 (BMPR2) is a major genetic risk factor in pulmonary arterial hypertension and EIF2AK4 potentially connects with BMPR2 to cause PCH. L-Arginine is substrate of nitric oxide synthase, and L-arginine is depleted during the production of nitric oxide, which may activate EIF2AK4 to inhibit protein synthesis and negatively regulate vasculogenesis. Mammalian target of rapamycin and EIF2α kinase are two major pathways for translational regulation. Mutant EIF2AK4 could promote proliferation of small pulmonary arteries by crosstalk with mammalian targets of the rapamycin signaling pathway. EIF2AK4 may regulate angiogenesis by modulating the immune system in PCH pathogenesis. The mechanisms of abnormal capillary angiogenesis are suggested to be similar to that of tumor vascularization. Specific therapies were developed according to pathogenesis and are proved to be effective in reported cases. Targeting the

  1. Crossed Fused Renal Ectopia: Presentations on 99mTc-MAG3 Scan, 99mTc-DMSA SPECT, and Multidetector CT.

    PubMed

    Moon, Eun Ha; Kim, Min-Woo; Kim, Young Jun; Sun, In O

    2015-10-01

    Crossed renal ectopia is an uncommon developmental anomaly in which both kidneys are located on the same side of the body. The present case describes a 20-year-old man who underwent the military entrance physical examination. The ultrasound showed the right kidney in normal site with slightly increased size, but the left kidney was not identified. Tc-MAG3 scan showed a single kidney with 2 ureters, and the orifices of the ureters were connected at both sides of bladder. Tc-DMSA SPECT and contrast-enhanced multidetector CT were performed and revealed crossed fused renal ectopia.

  2. Improving Outcomes in the Patient with Polytrauma: A Review of the Role of Whole-Body Computed Tomography.

    PubMed

    Gunn, Martin L; Kool, Digna R; Lehnert, Bruce E

    2015-07-01

    Whole-body computed tomography (WBCT) is used for the workup of the patient with blunt polytrauma. WBCT is associated with improved patient survival and reduces the emergency department length of stay. However, randomized studies are needed to determine whether early WBCT improves survival, to clarify which patients benefit the most, and to model the costs of this technique compared with traditional workup. Advancements in modern multidetector computed tomography technology and an improved understanding of optimal protocols have enabled one to scan the entire body and achieve adequate image quality for a comprehensive trauma assessment in a short period. PMID:26046503

  3. M. tuberculosis ferritin (Rv3841): Potential involvement in Amikacin (AK) & Kanamycin (KM) resistance.

    PubMed

    Sharma, Divakar; Lata, Manju; Faheem, Mohammad; Khan, Asad Ullah; Joshi, Beenu; Venkatesan, Krishnamurthy; Shukla, Sangeeta; Bisht, Deepa

    2016-09-16

    Tuberculosis is an infectious disease, caused by one of the most successful human pathogen, Mycobacterium tuberculosis. Aminoglycosides, Amikacin (AK) & Kanamycin (KM) are commonly used to treat drug resistant tuberculosis. They target the protein synthesis machinery by interacting with several steps of translation. Several explanations have been proposed to explain the mechanism of aminoglycoside resistance but still our information is inadequate. Iron storing/interacting proteins were found to be overexpressed in aminoglycosides resistant isolates. Iron assimilation and utilization in M. tuberculosis plays a crucial role in growth, virulence and latency. To establish the relationship of ferritin with AK & KM resistance ferritin (Rv3841/bfrB) was cloned, expressed and antimicrobial drug susceptibility testing (DST) was carried out. Rv3841/bfrB gene was cloned and expressed in E. coli BL21 using pQE2 expression vector. Etest results for DST against AK & KM showed that the minimum inhibitory concentration (MIC) of ferritin recombinant cells was changed. Recombinants showed two fold changes in MIC with AK and three fold with KM E-strips. Overexpression of ferritin reflect the MIC shift which might be playing a critical role in the survival of mycobacteria by inhibiting/modulating the effects of AK & KM. String analysis also suggests that ferritin interacted with few proteins which are directly and indirectly involved in M. tuberculosis growth, Iron assimilation, virulence, resistance, stresses and latency. PMID:27521892

  4. Assessment methodologies and statistical issues for computer-aided diagnosis of lung nodules in computed tomography: contemporary research topics relevant to the lung image database consortium.

    PubMed

    Dodd, Lori E; Wagner, Robert F; Armato, Samuel G; McNitt-Gray, Michael F; Beiden, Sergey; Chan, Heang-Ping; Gur, David; McLennan, Geoffrey; Metz, Charles E; Petrick, Nicholas; Sahiner, Berkman; Sayre, Jim

    2004-04-01

    Cancer of the lung and bronchus is the leading fatal malignancy in the United States. Five-year survival is low, but treatment of early stage disease considerably improves chances of survival. Advances in multidetector-row computed tomography technology provide detection of smaller lung nodules and offer a potentially effective screening tool. The large number of images per exam, however, requires considerable radiologist time for interpretation and is an impediment to clinical throughput. Thus, computer-aided diagnosis (CAD) methods are needed to assist radiologists with their decision making. To promote the development of CAD methods, the National Cancer Institute formed the Lung Image Database Consortium (LIDC). The LIDC is charged with developing the consensus and standards necessary to create an image database of multidetector-row computed tomography lung images as a resource for CAD researchers. To develop such a prospective database, its potential uses must be anticipated. The ultimate applications will influence the information that must be included along with the images, the relevant measures of algorithm performance, and the number of required images. In this article we outline assessment methodologies and statistical issues as they relate to several potential uses of the LIDC database. We review methods for performance assessment and discuss issues of defining "truth" as well as the complications that arise when truth information is not available. We also discuss issues about sizing and populating a database.

  5. Radiological protection in computed tomography and cone beam computed tomography.

    PubMed

    Rehani, M M

    2015-06-01

    The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT.

  6. A novel alpha kinase EhAK1 phosphorylates actin and regulates phagocytosis in Entamoeba histolytica.

    PubMed

    Mansuri, M Shahid; Bhattacharya, Sudha; Bhattacharya, Alok

    2014-10-01

    Phagocytosis plays a key role in nutrient uptake and virulence of the protist parasite Entamoeba histolytica. Phagosomes have been characterized by proteomics, and their maturation in the cells has been studied. However, there is so far not much understanding about initiation of phagocytosis and formation of phagosomes at the molecular level. Our group has been studying initiation of phagocytosis and formation of phagosomes in E. histolytica, and have described some of the molecules that play key roles in the process. Here we show the involvement of EhAK1, an alpha kinase and a SH3 domain containing protein in the pathway that leads to formation of phagosomes using red blood cell as ligand particle. A number of approaches, such as proteomics, biochemical, confocal imaging using specific antibodies or GFP tagged molecules, expression down regulation by antisense RNA, over expression of wild type and mutant proteins, were used to understand the role of EhAK1 in phagocytosis. EhAK1 was found in the phagocytic cups during the progression of cups, until closure of phagosomes, but not in the phagosomes themselves. It is recruited to the phagosomes through interaction with the calcium binding protein EhCaBP1. A reduction in phagocytosis was observed when EhAK1 was down regulated by antisense RNA, or by over expression of the kinase dead mutant. G-actin was identified as one of the major substrates of EhAK1. Phosphorylated actin preferentially accumulated at the phagocytic cups and over expression of a phosphorylation defective actin led to defects in phagocytosis. In conclusion, we describe an important component of the pathway that is initiated on attachment of red blood cells to E. histolytica cells. The main function of EhAK1 is to couple signalling events initiated after accumulation of EhC2PK to actin dynamics.

  7. Modification of radio-thermo-chemotherapy by AK-2123 and hydralazine in tumor bearing mice.

    PubMed

    Kunugita, N; Mei, N; Norimura, T; Kagiya, T V

    1996-09-01

    The effects of chemical modifiers of hypoxic radiosensitizer, a 3-nitrotriazole derivative AK-2123 (200 mg/kg) before treatment, and vasodilator of hydralazine (HDZ; 5.0 mg/kg) after treatment on tumor growth of SCCVII of mice were investigated in the radio-thermotherapy combined with mitomycin C (MMC; 2.0 mg/kg) or adriamycin (ADM; 3 mg/kg). The tumor treated by 10 Gy alone (tumor doubling time = 7.5 days), MMC alone (6.9 days), and hyperthermia (43 degrees C, 30 min; HT) alone (8.0 days) showed a slight growth delay (control: 5.6 days). Prolonged growth delay (23.2 days) was observed by MMC-radio-thermotherapy (MMC-10Gy/HT) than that (12.4 days) by 10 Gy/HT. The modification of MMC-radio-thermotherapy by HDZ administered between 10 Gy and HT (MMC-10 Gy/HDZ/HT) resulted in the significant prolongation of tumor growth delay (31.7 days). AK-2123 administration before this treatment, (MMC-AK-2123)-10 Gy/HDZ/HT), enhanced a further tumor growth delay (37.6 days) which is equal to that by 50 Gy alone and resulted in the highest dose modifying factor (DMF) of 5.2. While modification of ADM-radio-thermotherapy by AK-2123 and HDZ, (ADM-AK-2123)-10 Gy/HDZ/HT, gave the equal tumor growth delay to that by 30 Gy alone (DMF = 3.1). These high efficacies of radio-thermo-chemotherapy modified by AK-2123 and HDZ may be caused by tumor blood flow reduction.

  8. A Novel Alpha Kinase EhAK1 Phosphorylates Actin and Regulates Phagocytosis in Entamoeba histolytica

    PubMed Central

    Mansuri, M. Shahid; Bhattacharya, Sudha; Bhattacharya, Alok

    2014-01-01

    Phagocytosis plays a key role in nutrient uptake and virulence of the protist parasite Entamoeba histolytica. Phagosomes have been characterized by proteomics, and their maturation in the cells has been studied. However, there is so far not much understanding about initiation of phagocytosis and formation of phagosomes at the molecular level. Our group has been studying initiation of phagocytosis and formation of phagosomes in E. histolytica, and have described some of the molecules that play key roles in the process. Here we show the involvement of EhAK1, an alpha kinase and a SH3 domain containing protein in the pathway that leads to formation of phagosomes using red blood cell as ligand particle. A number of approaches, such as proteomics, biochemical, confocal imaging using specific antibodies or GFP tagged molecules, expression down regulation by antisense RNA, over expression of wild type and mutant proteins, were used to understand the role of EhAK1 in phagocytosis. EhAK1 was found in the phagocytic cups during the progression of cups, until closure of phagosomes, but not in the phagosomes themselves. It is recruited to the phagosomes through interaction with the calcium binding protein EhCaBP1. A reduction in phagocytosis was observed when EhAK1 was down regulated by antisense RNA, or by over expression of the kinase dead mutant. G-actin was identified as one of the major substrates of EhAK1. Phosphorylated actin preferentially accumulated at the phagocytic cups and over expression of a phosphorylation defective actin led to defects in phagocytosis. In conclusion, we describe an important component of the pathway that is initiated on attachment of red blood cells to E. histolytica cells. The main function of EhAK1 is to couple signalling events initiated after accumulation of EhC2PK to actin dynamics. PMID:25299184

  9. A retrospective comparison of smart prep and test bolus multi-detector CT pulmonary angiography protocols

    SciTech Connect

    Suckling, Tara; Smith, Tony; Reed, Warren

    2013-06-15

    Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 and February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.

  10. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

    PubMed

    Turner, Adam C; Zhang, Di; Kim, Hyun J; DeMarco, John J; Cagnon, Chris H; Angel, Erin; Cody, Dianna D; Stevens, Donna M; Primak, Andrew N; McCollough, Cynthia H; McNitt-Gray, Michael F

    2009-06-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called "equivalent" source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL1 and HVL2) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL1 and HVL2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types result in

  11. Feature-based characterization of motion-contaminated calcified plaques in cardiac multidetector CT

    SciTech Connect

    King, Martin; Giger, Maryellen L.; Suzuki, Kenji; Pan, Xiaochuan

    2007-12-15

    features mostly involved intensity-based features. Edge-based volume/irregularity and average margin gradient/variance of margin gradient were the only two feature pairs out of 12 with stronger correlations that did not involve intensity-based features. Automatically extracted features of the motion artifacts affecting calcified plaques in cardiac computed tomography images potentially can be used to develop models for predicting image assessability with respect to motion artifacts.

  12. Computerized assessment of motion-contaminated calcified plaques in cardiac multidetector CT

    SciTech Connect

    King, Martin; Giger, Maryellen L.; Suzuki, Kenji; Bardo, Dianna M. E.; Greenberg, Brent; Lan Li; Pan Xiaochuan

    2007-12-15

    An automated method for evaluating the image quality of calcified plaques with respect to motion artifacts in noncontrast-enhanced cardiac computed tomography (CT) images is introduced. This method involves using linear regression (LR) and artificial neural network (ANN) regression models for predicting two patient-specific, region-of-interest-specific, reconstruction-specific and temporal phase-specific image quality indices. The first is a plaque motion index, which is derived from the actual trajectory of the calcified plaque and is represented on a continuous scale. The second is an assessability index, which reflects the degree to which a calcified plaque is affected by motion artifacts, and is represented on an ordinal five-point scale. Two sets of assessability indices were provided independently by two radiologists experienced in evaluating cardiac CT images. Inputs for the regression models were selected from 12 features characterizing the dynamic, morphological, and intensity-based properties of the calcified plaques. Whereas LR-velocity (LR-V) used only a single feature (three-dimensional velocity), the LR-multiple (LR-M) and ANN regression models used the same subset of these 12 features selected through stepwise regression. The regression models were parameterized and evaluated using a database of simulated calcified plaque images from the dynamic NCAT phantom involving nine heart rate/multi-sector gating combinations and 40 cardiac phases covering two cardiac cycles. Six calcified plaques were used for the plaque motion indices and three calcified plaques were used for both sets of assessability indices. In one configuration, images from the second cardiac cycle were used for feature selection and regression model parameterization, whereas images from the first cardiac cycle were used for testing. With this configuration, repeated measures concordance correlation coefficients (CCCs) and associated 95% confidence intervals for the LR-V, LR-M, and ANN

  13. 75 FR 62457 - Establishment of Class E Airspace; Port Clarence, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... Federal Register to establish Class E airspace at Port Clarence, AK (75 FR 34393). Interested parties were... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does... U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec....

  14. 77 FR 65253 - Amendment of Area Navigation Route T-240; AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-26

    ... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does..., 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The incorporation... Administration 14 CFR Part 71 RIN 2120-AA66 Amendment of Area Navigation Route T-240; AK AGENCY: Federal...

  15. 75 FR 17322 - Proposed Revocation of Class D and E Airspace; Big Delta, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-06

    ... Federal Aviation Administration 14 CFR Part 71 Proposed Revocation of Class D and E Airspace; Big Delta...). SUMMARY: This action proposes to revoke Class D and E airspace at Big Delta, AK. This airspace duplicates... rulemaking by submitting such written data, views, or arguments as they may desire. Comments that provide...

  16. 75 FR 23804 - Notice of Inventory Completion: Alaska State Office, Bureau of Land Management, Anchorage, AK...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-04

    ... National Park Service Notice of Inventory Completion: Alaska State Office, Bureau of Land Management... completion of an inventory of human remains and associated funerary objects in the control of the U.S. Department of the Interior, Bureau of Land Management, Alaska State Office, Anchorage, AK, and in...

  17. 77 FR 31353 - An Assessment of Potential Mining Impacts on Salmon Ecosystems of Bristol Bay, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-25

    ... draft document addresses potential impacts to water quality and the salmon fishery that may result from... AGENCY An Assessment of Potential Mining Impacts on Salmon Ecosystems of Bristol Bay, AK AGENCY... of Potential Mining Impacts on Salmon Ecosystems of Bristol Bay, Alaska'' (EPA-910-R-12-004a-d)....

  18. 75 FR 32652 - Revocation and Establishment of Class E Airspace; Nuiqsut, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-09

    ... privately owned heliport facilities at Oooguruk, AK (74 FR 45554). The two heliports were named ``Oooguruk... Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of.... 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0...

  19. 76 FR 54151 - Proposed Amendment of Class E Airspace; Kwigillingok, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ...; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February...; Kwigillingok, AK AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed rulemaking... to enhance safety and management of Instrument Flight Rules (IFR) operations. DATES: Comments must...

  20. 77 FR 49720 - Establishment of Class E Airspace; Chenega Bay, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-17

    ... proposed rulemaking (NPRM) to establish controlled airspace at Chenega Bay, AK (77 FR 31548). Interested... Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of a...: Authority: 49 U.S.C. 106(g), 40103, 40113, 40120; E. O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p....

  1. 78 FR 76055 - Establishment of Class E Airspace; Donlin Creek, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ... rulemaking (NPRM) to establish controlled airspace at Donlin Creek, AK (78 FR 58490). Interested parties were...'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant... FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The incorporation by reference in 14 CFR...

  2. 78 FR 50322 - Amendment of Class E Airspace; Point Thomson, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-19

    ... controlled airspace at Point Thomson, AK (78 FR 30797). Interested parties were invited to participate in... a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979..., 40113, 40120; E. O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The...

  3. 75 FR 77572 - Proposed Revision of Class E Airspace; Platinum AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ...; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February.... 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 2. The... Federal Aviation Administration 14 CFR Part 71 Proposed Revision of Class E Airspace; Platinum AK...

  4. 78 FR 59806 - Establishment of Class E Airspace; White Mountain, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-30

    ..., Airport, White Mountain, AK (77 FR 75598). Interested parties were invited to participate in this... Executive Order 12866; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR...: Authority: 49 U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p....

  5. 78 FR 65208 - Modification of Class D and E Airspace; Kenai, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ... modify controlled airspace at Kenai Municipal Airport, Kenai, AK (78 FR 34609). Interested parties were... extending to 10.2 miles northeast of the airport is adjusted to coincide with the dimensions of the cutout... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3)...

  6. 75 FR 30746 - Proposed Revocation and Establishment of Class E Airspace; Northeast, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-02

    ... providing service to Eagle, AK, must currently operate under Visual Flight Rules (VFR). With the... Regulatory Policies ] and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation... A, CLASS B, CLASS C, CLASS D, AND CLASS E AIRSPACE AREAS; AIR TRAFFIC SERVICE ROUTES; AND...

  7. 78 FR 17083 - Amendment of Class E Airspace; Scammon Bay, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... Bay, AK (77 FR 27146). Interested parties were invited to participate in this rulemaking effort by... Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of... FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The incorporation by reference in 14 CFR...

  8. 75 FR 12680 - Revision of Class E Airspace; Scammon Bay, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ...-2850; e-mail: gary.ctr.rolf@faa.gov . Internet address: http://www.faa.gov/about/office_org/headquarters_offices/ato/service_units/systemops/fs/alaskan/rulemaking/ . SUPPLEMENTARY INFORMATION: History On... revise Class E airspace at Scammon Bay, AK (74 FR 66597). Interested parties were invited to...

  9. 78 FR 48299 - Establishment of Class D Airspace; Bryant AAF, Anchorage, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-08

    ..., Anchorage AK (77 FR 50646). Interested parties were invited to participate in this rulemaking effort by... would eliminate that portion east of Glenn Highway (FR 78 34608, June 10, 2013). Interested parties were... Executive Order 12866; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44...

  10. 75 FR 17892 - Proposed Revision of Class E Airspace; Galena, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-08

    ... Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3) does not warrant preparation of... follows: Authority: 49 U.S.C. 106(g), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp... Federal Aviation Administration 14 CFR Part 71 Proposed Revision of Class E Airspace; Galena, AK...

  11. 77 FR 6 - Amendment of Class E Airspace; Galbraith Lake, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    ... amend controlled airspace at Galbraith Lake, AK (76 FR 54152). Interested parties were invited to... Executive Order 12866; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR...), 40103, 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2....

  12. 75 FR 34624 - Revocation of Class D and E Airspace; Big Delta, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ... airspace at Big Delta, AK (75 FR 17322). Controlled airspace serving Allen Army Airfield was revised in...; (2) is not a ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February..., 40113, 40120; E.O. 10854, 24 FR 9565, 3 CFR, 1959-1963 Comp., p. 389. Sec. 71.1 0 2. The...

  13. 78 FR 58158 - Establishment of Class D Airspace; Bryant AAF, Anchorage, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-23

    ... Register establishing Class D airspace at Bryant AAF, Anchorage, AK (78 FR 48299, August 8, 2013). In the..., as published in the Federal Register on August 8, 2013 (78 FR 48299), FR Doc. 2013-18866, are... description for Bryant AAF, in that the language indicating Class D airspace as part time was left out....

  14. 75 FR 44884 - Revision of Class E Airspace; Kulik Lake, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-30

    ... address: http://www.faa.gov/about/office_org/headquarters_offices/ato/service_units/systemops/fs/alaskan... proposed rulemaking in the Federal Register to revise Class E airspace at Kulik Lake, AK (75 FR 26151... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3)...

  15. 75 FR 62460 - Revocation and Establishment of Class E Airspace; Northeast Alaska, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... address: http://www.faa.gov/about/office_org/headquarters_offices/ato/service_units/systemops/fs/alaskan... establish other Class E airspace near the Eagle Airport, Eagle, AK (75 FR 30746). The proposal did not fully... ``significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034; February 26, 1979); and (3)...

  16. Genomic characterization of Sinorhizobium meliloti AK21, a wild isolate from the Aral Sea Region.

    PubMed

    Molina-Sánchez, María Dolores; López-Contreras, José Antonio; Toro, Nicolás; Fernández-López, Manuel

    2015-01-01

    The symbiotic, nitrogen-fixing bacterium Sinorhizobium meliloti has been widely studied due to its ability to improve crop yields through direct interactions with leguminous plants. S. meliloti AK21 is a wild type strain that forms nodules on Medicago plants in saline and drought conditions in the Aral Sea Region. The aim of this work was to establish the genetic similarities and differences between S. meliloti AK21 and the reference strain S. meliloti 1021. Comparative genome hybridization with the model reference strain S. meliloti 1021 yielded 365 variable genes, grouped into 11 regions in the three main replicons in S. meliloti AK21. The most extensive regions of variability were found in the symbiotic plasmid pSymA, which also contained the largest number of orthologous and polymorphic sequences identified by suppression subtractive hybridization. This procedure identified a large number of divergent sequences and others without homology in the databases, the further investigation of which could provide new insight into the alternative metabolic pathways present in S. meliloti AK21. We identified a plasmid replication module from the repABC replicon family, together with plasmid mobilization-related genes (traG and a VirB9-like protein), which suggest that this indigenous isolate harbors an accessory plasmid. Furthermore, the transcriptomic profiles reflected differences in gene content and regulation between S. meliloti AK21 and S. meliloti 1021 (ExpR and PhoB regulons), but provided evidence for an as yet unknown, alternative mechanism involving activation of the cbb3 terminal oxidase. Finally, phenotypic microarrays characterization revealed a greater versatility of substrate use and chemical degradation than for S. meliloti 1021.

  17. Genomic characterization of Sinorhizobium meliloti AK21, a wild isolate from the Aral Sea Region.

    PubMed

    Molina-Sánchez, María Dolores; López-Contreras, José Antonio; Toro, Nicolás; Fernández-López, Manuel

    2015-01-01

    The symbiotic, nitrogen-fixing bacterium Sinorhizobium meliloti has been widely studied due to its ability to improve crop yields through direct interactions with leguminous plants. S. meliloti AK21 is a wild type strain that forms nodules on Medicago plants in saline and drought conditions in the Aral Sea Region. The aim of this work was to establish the genetic similarities and differences between S. meliloti AK21 and the reference strain S. meliloti 1021. Comparative genome hybridization with the model reference strain S. meliloti 1021 yielded 365 variable genes, grouped into 11 regions in the three main replicons in S. meliloti AK21. The most extensive regions of variability were found in the symbiotic plasmid pSymA, which also contained the largest number of orthologous and polymorphic sequences identified by suppression subtractive hybridization. This procedure identified a large number of divergent sequences and others without homology in the databases, the further investigation of which could provide new insight into the alternative metabolic pathways present in S. meliloti AK21. We identified a plasmid replication module from the repABC replicon family, together with plasmid mobilization-related genes (traG and a VirB9-like protein), which suggest that this indigenous isolate harbors an accessory plasmid. Furthermore, the transcriptomic profiles reflected differences in gene content and regulation between S. meliloti AK21 and S. meliloti 1021 (ExpR and PhoB regulons), but provided evidence for an as yet unknown, alternative mechanism involving activation of the cbb3 terminal oxidase. Finally, phenotypic microarrays characterization revealed a greater versatility of substrate use and chemical degradation than for S. meliloti 1021. PMID:26090306

  18. Kinetics of nutrient enhanced crude oil degradation by Pseudomonas aeruginosa AKS1 and Bacillus sp. AKS2 isolated from Guwahati refinery, India.

    PubMed

    Chettri, Bobby; Mukherjee, Arghya; Langpoklakpam, James S; Chattopadhyay, Dhrubajyoti; Singh, Arvind K

    2016-09-01

    Bacterial degradation of crude oil in response to nutrient treatments has been vastly studied. But there is a paucity of information on kinetic parameters of crude oil degradation. Here we report the nutrient stimulated kinetic parameters of crude oil degradation assessed in terms of CO2 production and oil removal by Pseudomonas aeruginosa AKS1 and Bacillus sp. AKS2. The hydrocarbon degradation rate of P. aeruginosa AKS1 in oil only amended sediment was 10.75 ± 0.65 μg CO2-C g(-1) sediment day(-1) which was similar to degradation rate in sediments with no oil. In presence of both inorganic N & P, the degradation rate increased to 47.22 ± 1.32 μg CO2-C g(-1) sediment day(-1). The half-saturation constant (Ks) and maximum degradation rate (Vmax) for P. aeruginosa AKS1 under increasing N and saturating P concentration were 13.57 ± 0.53 μg N g(-1) sediment and 39.36 ± 1.42 μg CO2-C g(-1) sediment day(-1) respectively. The corresponding values at increasing P and a constant N concentration were 1.60 ± 0.13 μg P g(-1) sediment and 43.90 ± 1.03 μg CO2-C g(-1) sediment day(-1) respectively. Similarly the degradation rate of Bacillus sp. AKS2 in sediments amended with both inorganic nutrients N & P was seven fold higher than the rates in oil only or nutrient only treated sediments. The Ks and Vmax estimates of Bacillus sp. AKS2 under increasing N and saturating P concentration were 9.96 ± 1.25 μg N g(-1) sediment and 59.96 ± 7.56 μg CO2-C g(-1) sediment day(-1) respectively. The corresponding values for P at saturating N concentration were 0.46 ± 0.24 μg P g(-1) sediment and 63.63 ± 3.54 μg CO2-C g(-1) sediment day(-1) respectively. The rates of CO2 production by both isolates were further stimulated when oil concentration was increased above 12.5 mg g(-1) sediment. However, oil degradation activity declined at oil concentration above 40 mg g(-1) sediment when treated with constant nutrient: oil ratio

  19. Kinetics of nutrient enhanced crude oil degradation by Pseudomonas aeruginosa AKS1 and Bacillus sp. AKS2 isolated from Guwahati refinery, India.

    PubMed

    Chettri, Bobby; Mukherjee, Arghya; Langpoklakpam, James S; Chattopadhyay, Dhrubajyoti; Singh, Arvind K

    2016-09-01

    Bacterial degradation of crude oil in response to nutrient treatments has been vastly studied. But there is a paucity of information on kinetic parameters of crude oil degradation. Here we report the nutrient stimulated kinetic parameters of crude oil degradation assessed in terms of CO2 production and oil removal by Pseudomonas aeruginosa AKS1 and Bacillus sp. AKS2. The hydrocarbon degradation rate of P. aeruginosa AKS1 in oil only amended sediment was 10.75 ± 0.65 μg CO2-C g(-1) sediment day(-1) which was similar to degradation rate in sediments with no oil. In presence of both inorganic N & P, the degradation rate increased to 47.22 ± 1.32 μg CO2-C g(-1) sediment day(-1). The half-saturation constant (Ks) and maximum degradation rate (Vmax) for P. aeruginosa AKS1 under increasing N and saturating P concentration were 13.57 ± 0.53 μg N g(-1) sediment and 39.36 ± 1.42 μg CO2-C g(-1) sediment day(-1) respectively. The corresponding values at increasing P and a constant N concentration were 1.60 ± 0.13 μg P g(-1) sediment and 43.90 ± 1.03 μg CO2-C g(-1) sediment day(-1) respectively. Similarly the degradation rate of Bacillus sp. AKS2 in sediments amended with both inorganic nutrients N & P was seven fold higher than the rates in oil only or nutrient only treated sediments. The Ks and Vmax estimates of Bacillus sp. AKS2 under increasing N and saturating P concentration were 9.96 ± 1.25 μg N g(-1) sediment and 59.96 ± 7.56 μg CO2-C g(-1) sediment day(-1) respectively. The corresponding values for P at saturating N concentration were 0.46 ± 0.24 μg P g(-1) sediment and 63.63 ± 3.54 μg CO2-C g(-1) sediment day(-1) respectively. The rates of CO2 production by both isolates were further stimulated when oil concentration was increased above 12.5 mg g(-1) sediment. However, oil degradation activity declined at oil concentration above 40 mg g(-1) sediment when treated with constant nutrient: oil ratio

  20. Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.; Mitchell, Mark A.

    2016-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance chlorofluorocarbon-113 was banned, NASA's propulsion test facilities at Marshall Space Flight Center and Stennis Space Center have relied upon the solvent Asahiklin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

  1. Three‐dimensional scanning with dual‐source computed tomography in patients with acute skeletal trauma

    PubMed Central

    Yildirim, Duzgun; Tamam, Cuneyt; Gumus, Terman

    2010-01-01

    OBJECTIVE: The aim of this study was to compare the efficiency of multiplanar reformatted images and three‐dimensional images created after multidetector computed tomography examination in detecting acute post‐traumatic osseous pathology of the skeletal system. METHOD: Between October 2006 and December 2008, 105 patients with a history of acute trauma were referred to our service. Patients were evaluated with multidetector computed tomography using multiplanary reconstructed images initially (R‐I), and six months after this initial evaluation, three‐dimensional images were assessed of each patient (R‐II). Axial images were used for guiding as a reference Data obtained was recorded and graded according to importance levels of the pathologies. RESULTS: The R‐II score was higher in the non‐articular and highest in periartricular fractures of the extremities, and thoracic and pelvic cage injuries. For the spinal column, while R‐I data was more significant In patients referred with polytrauma, R‐II data, was more statistically significant, for short processing and adaptation time to acquiring immediate critical information. For all cases it was seen that three dimensional scans were more efficient in providing the orientation, within a short time. CONCLUSION: By dual source multidedector tomography systems trauma patients may be evaluated by multiplanary and three dimensionally reconstructed images. When used correctly, three dimensional imaging is advantageous and can help determine the exact nature and extension and also importance of osseous injuries. PMID:21120300

  2. Computed tomographic colonography (CTC): Possibilities and limitations of clinical application in colorectal polyps and cancer.

    PubMed

    Heuschmid, Martin; Luz, Oliver; Schaefer, Juergen F; Kopp, Andreas F; Claussen, Claus D; Seemann, Marcus D

    2004-04-01

    Colorectal cancer is the second leading cause of cancer-related deaths in Europe and the United States. Most colorectal cancers develop from adenomatous polyps over a number of years. Early detection of polyps eliminates the risk of subsequent carcinomas. Computed tomographic (CT) colonography is a diagnostic technique detecting colorectal neoplasms. With the introduction of multidetector-row computed tomography (MD-CT), CT colonography (CTC) has gained influence as a new diagnostic tool in early detection of colonic pathologies by acquiring volumetric CT data sets of the abdomen. This volumetric data is analyzed using CTC workstations, which provide an interactive display of 2D and 3D images of the colon. In several studies, CTC revealed a high accuracy (sensitivity/patient: 83-100% and specificity/patient: 93-100%) in detecting pathological colonic changes. Furthermore, CTC is an excellent diagnostic technique for the evaluation of patients with incomplete conventional colonoscopy and allows the assessment of extracolonic abdominal and pelvic organs. In this article, the status of CT colonography as a method of detecting colonic polyps and colorectal carcinomas using single- and multidetector-row CT will be reviewed.

  3. Crystal structure of Clostridium acetobutylicum Aspartate kinase (CaAK): An important allosteric enzyme for amino acids production.

    PubMed

    Manjasetty, Babu A; Chance, Mark R; Burley, Stephen K; Panjikar, Santosh; Almo, Steven C

    2014-09-01

    Aspartate kinase (AK) is an enzyme which is tightly regulated through feedback control and responsible for the synthesis of 4-phospho-L-aspartate from L-aspartate. This intermediate step is at an important branch point where one path leads to the synthesis of lysine and the other to threonine, methionine and isoleucine. Concerted feedback inhibition of AK is mediated by threonine and lysine and varies between the species. The crystal structure of biotechnologically important Clostridium acetobutylicum aspartate kinase (CaAK; E.C. 2.7.2.4; Mw=48,030Da; 437aa; SwissProt: Q97MC0) has been determined to 3Å resolution. CaAK acquires a protein fold similar to the other known structures of AKs despite the low sequence identity (<30%). It is composed of two domains: an N-terminal catalytic domain (kinase) domain and a C-terminal regulatory domain further comprised of two small domains belonging to the ACT domain family. Pairwise comparison of 12 molecules in the asymmetric unit helped to identify the bending regions which are in the vicinity of ATP binding site involved in domain movements between the catalytic and regulatory domains. All 12 CaAK molecules adopt fully open T-state conformation leading to the formation of three tetramers unique among other similar AK structures. On the basis of comparative structural analysis, we discuss tetramer formation based on the large conformational changes in the catalytic domain associated with the lysine binding at the regulatory domains. The structure described herein is homologous to a target in wide-spread pathogenic (toxin producing) bacteria such as Clostridium tetani (64% sequence identity) suggesting the potential of the structure solved here to be applied for modeling drug interactions. CaAK structure may serve as a guide to better understand and engineer lysine biosynthesis for the biotechnology industry.

  4. Novel clinical applications of dual energy computed tomography.

    PubMed

    Kraśnicki, Tomasz; Podgórski, Przemysław; Guziński, Maciej; Czarnecka, Anna; Tupikowski, Krzysztof; Garcarek, Jerzy; Marek Sąsiadek, Marek

    2012-01-01

    Dual energy CT (DECT) was conceived at the very beginning of the computed tomography era. However the first DECT scanner was developed in 2006. Nowadays there are three different types of DECT available: dual-source CT with 80(100) kVp and 140 kVp tubes (Siemens Medical Solution); dual-layer multi-detector scanner with acquisition 120 or 140kVp (Philips Healthcare); CT unit with one rapid kVp switching source and new detector based on gemstone scintillator materials (GE Healthcare). This article describes the physical background and principles of DECT imaging as well as applications of this innovative method in routine clinical practice (renal stone differentiation, pulmonary perfusion, neuroradiology and metallic implant imaging). The particular applications are illustrated by cases from author's material.

  5. Silencing the HaAK gene by transgenic plant-mediated RNAi impairs larval growth of Helicoverpa armigera.

    PubMed

    Liu, Feng; Wang, Xiao-Dong; Zhao, Yi-Ying; Li, Yan-Jun; Liu, Yong-Chang; Sun, Jie

    2015-01-01

    Insect pests have caused noticeable economic losses in agriculture, and the heavy use of insecticide to control pests not only brings the threats of insecticide resistance but also causes the great pollution to foods and the environment. Transgenic plants producing double-stranded RNA (dsRNA) directed against insect genes have been is currently developed for protection against insect pests. In this study, we used this technology to silence the arginine kinase (AK) gene of Helicoverpa armigera (HaAK), encoding a phosphotransferase that plays a critical role in cellular energy metabolism in invertebrate. Transgenic Arabidopsis plants producing HaAK dsRNA were generated by Agrobacterium-mediated transformation. The maximal mortality rate of 55% was reached when H. armigera first-instar larvae were fed with transgenic plant leaves for 3 days, which was dramatically higher than the 18% mortality recorded in the control group. Moreover, the ingestion of transgenic plants significantly retarded larval growth, and the transcript levels of HaAK were also knocked down by up to 52%. The feeding bioassays further indicated that the inhibition efficiency was correlated with the integrity and concentration of the produced HaAK dsRNA in transgenic plants. These results strongly show that the resistance to H. armigera was improved in transgenic Arabidopsis plants, suggesting that the RNAi targeting of AK has the potential for the control of insect pests. PMID:25552931

  6. Computers and Computer Resources.

    ERIC Educational Resources Information Center

    Bitter, Gary

    1980-01-01

    This resource directory provides brief evaluative descriptions of six popular home computers and lists selected sources of educational software, computer books, and magazines. For a related article on microcomputers in the schools, see p53-58 of this journal issue. (SJL)

  7. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Gu, J.; Bednarz, B.; Caracappa, P. F.; Xu, X. G.

    2009-05-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  8. 120. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    120. Back side technical facilities S.R. radar transmitter & computer building no. 102, section II "foundation & first floor plan" - structural, AS-BLT AW 35-46-04, sheet 65, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  9. 118. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    118. Back side technical facilities S.R. radar transmitter & computer building no. 102, "building sections - sheet I" - architectural, AS-BLT AW 35-46-04, sheet 13, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  10. 122. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    122. Back side technical facilities S.R. radar transmitter & computer building no. 102, section II "elevations & details" - structural, AS-BLT AW 35-46-04, sheet 73, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  11. 121. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    121. Back side technical facilities S.R. radar transmitter & computer building no. 102, section II "sections & elevations" - structural, AS-BLT AW 35-46-04, sheet 72, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  12. 117. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. Back side technical facilities S.R. radar transmitter & computer building no. 102, "building sections - sheet I" - architectural, AS-BLT AW 35-46-04, sheet 12, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  13. 119. Back side technical facilities S.R. radar transmitter & computer ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    119. Back side technical facilities S.R. radar transmitter & computer building no. 102, section I "tower plan, sections & details" - structural, AS-BLT AW 35-46-04, sheet 62, dated 23 January, 1961. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  14. A case of a giant mucocoele of the appendiceal stump presented with a palpable mass in the right thigh: pre-operative diagnosis based on characteristic multidetector CT findings.

    PubMed

    Kim, M K; Lee, H Y; Song, I S; Lee, J B; Kim, G H; Yoo, S M; Rho, J Y; White, C S

    2010-10-01

    The pre-operative diagnosis of a mucocoele of the appendiceal stump (MAS) may be difficult owing to rarity and non-specific clinical presentation. However, a pre-operative diagnosis of a MAS is important to prevent widespread dissemination by inadvertent spillage of mucous contents. We describe a case of a MAS presenting with a palpable mass in the right thigh in which a pre-operative diagnosis was made by characteristic multidetector CT (MDCT) findings.

  15. Thermodynamic properties of La{sub 1−x}A{sub x}CoO₃ (A=K, Cd, Pr and Nd)

    SciTech Connect

    Thakur, Rasna; Gaur, N.K.

    2013-05-01

    We have calculated the thermal and allied properties of La{sub 1–x}A{sub x}CoO₃ (A=K, Cd, Pr, Nd and 0≤x≤1) as a function of temperature 1 K≤T≤300 K for the first time using Modified Rigid Ion Model (MRIM). The calculated bulk modulus, specific heat, thermal expansion and other thermodynamic properties obtained from MRIM have presented proper interpretation of the experimental data, for monovalent (K⁺), divalent (Cd₂⁺) and trivalent (Pr³⁺ and Nd³⁺) ion-doped LaCoO₃. In addition, the results on the cohesive energy (Φ), molecular force constant (f), Reststrahlen frequency (υ), Debye temperature (θ}) and Gruneisen parameter (γ) are also discussed. - Graphical abstract: Substitution to trivalent La³⁺ site by K⁺ ions increase the thermal expansion (α) whereas Cd²⁺, Pr³⁺ and Nd³⁺ results in decrease of α in La{sub 1–x}A{sub x}CoO₃₋ (A=K, Cd, Pr, Nd). Highlights: • Probably the first report on the specific heat and thermal expansion in La{sub 1–x}A{sub x}CoO₃. • Thermal properties are computed using the MRIM probably for the first time. • Effect of lattice distortions on bulk modulus and thermal properties is presented. • The negative values of cohesive energy show the stability of these compounds.

  16. Non-invasive Detection of Aortic and Coronary Atherosclerosis in Homozygous Familial Hypercholesterolemia by 64 Slice Multi-detector Row Computed Tomography Angiography

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector-row ...

  17. Non-invasive detection of aortic and coronary atherosclerosis in homozygous familial hypercholesterolemia by 64 slice multi-detector row computed tomography angiography

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...

  18. Differentiation of Malignant and Benign Incidental Breast Lesions Detected by Chest Multidetector-Row Computed Tomography: Added Value of Quantitative Enhancement Analysis

    PubMed Central

    Lin, Yu-Pang; Hsu, Hsian-He; Ko, Kai-Hsiung; Chu, Chi-Ming; Chou, Yu-Ching; Chang, Wei-Chou; Chang, Tsun-Hou

    2016-01-01

    To retrospectively determine the association between breast lesion morphology and malignancy and to determine the optimal value of lesion enhancement (HU, Hounsfield units) to improve the diagnostic accuracy of breast cancer in patients with incidental breast lesions (IBLs). A total of 97 patients with 102 IBLs detected from July 2009 to December 2012 were enrolled in this study. Two radiologists analyzed CT images for the presence of malignancy based on the morphology of the lesions alone and in combination with an enhancement value (HU) analysis. There were 36 malignant and 66 benign IBLs. When the morphology and enhancement values were combined, the sensitivity, specificity, and accuracy were 92%, 97%, and 95%, respectively, for reader 1 and 89%, 94%, and 92%, respectively, for reader 2. The addition of HU values led to correct changes in the diagnosis; specifically, the accuracy of the diagnosis of reader 1 and reader 2 improved by 6.9% and 11.8%, respectively. The addition of the enhancement value (HU) to the CT morphology improved the diagnostic accuracy in the differentiation of malignant from benign IBLs by using the region of interest (ROI) to measure the HU within the most suspicious part of the lesion. PMID:27128524

  19. Pulmonary Findings on Computed Tomography in Asymptomatic Total Joint Arthroplasty Patients.

    PubMed

    Vigdorchik, Jonathan M; Riesgo, Aldo M; Lincoln, Denis; Markel, David C

    2016-08-01

    An increase in the diagnosis of pulmonary embolus (PE) in the early postoperative period has been attributed to the use of multidetector 64-slice computed tomographic (CT) scans. It was suspected that this finding was the result of marrow or fat emboli that are commonly associated with arthroplasty rather than a true venous thromboembolic phenomenon. The purpose of this study was to determine the baseline pulmonary findings in asymptomatic patients after total joint arthroplasty (TJA). Over a 1-year period, an institutional review board-approved prospective study of 20 asymptomatic patients using a multidetector 64-slice CT scanner was performed. Overall, 15 TKAs and 5 total hip arthroplasties were included for analysis. All of the CT scans were negative for PE. There were no signs of microemboli or fat emboli on any scan. No patient went on to develop a PE at 2 years postoperatively. Despite the fact that emboli are created during TJA, if emboli are seen on a CT scan postoperatively, they should be assumed to be real events with clinical sequelae. If pulmonary symptoms develop postoperatively, they should not simply be assumed to be the result of fat or marrow embolism.

  20. The role of computed tomography in terminal ballistic analysis.

    PubMed

    Rutty, G N; Boyce, P; Robinson, C E; Jeffery, A J; Morgan, B

    2008-01-01

    Terminal ballistics concerns the science of projectile behaviour within a target and includes wound ballistics that considers what happens when a projectile strikes a living being. A number of soft tissue ballistic simulants have been used to assess the damage to tissue caused by projectiles. Standard assessment of these materials, such as ballistic soap or ordnance gelatine, requires the block to be opened or that a mould to be made to visualize the wound track. This is time consuming and may affect the accuracy of the findings especially if the block dries and alters shape during the process. Therefore, accurate numerical analysis of the permanent or temporary cavity is limited. Computed tomography (CT) potentially offers a quicker non-invasive analysis tool for this task. Four commercially purchased ballistic glycerine soap blocks were used. Each had a single firearm discharged into it from a distance of approximately 15 cm using both gunshot and shotgun projectiles. After discharge, each block was imaged by a modern 16 slice multi-detector CT scanner and analysed using 3-D reconstruction software. Using the anterior-posterior and lateral scout views and the multi-plane reconstructed images, it was possible to visualize the temporary cavity, as well as the fragmentation and dispersal pattern of the projectiles, the distance travelled and angle of dispersal within the block of each projectile or fragment. A virtual cast of the temporary cavity can be also be made. Multi-detector CT with 3-D analysis software is shown to create a reliable permanent record of the projectile path allowing rapid analysis of different firearms and projectiles. PMID:17205351

  1. The role of computed tomography in terminal ballistic analysis.

    PubMed

    Rutty, G N; Boyce, P; Robinson, C E; Jeffery, A J; Morgan, B

    2008-01-01

    Terminal ballistics concerns the science of projectile behaviour within a target and includes wound ballistics that considers what happens when a projectile strikes a living being. A number of soft tissue ballistic simulants have been used to assess the damage to tissue caused by projectiles. Standard assessment of these materials, such as ballistic soap or ordnance gelatine, requires the block to be opened or that a mould to be made to visualize the wound track. This is time consuming and may affect the accuracy of the findings especially if the block dries and alters shape during the process. Therefore, accurate numerical analysis of the permanent or temporary cavity is limited. Computed tomography (CT) potentially offers a quicker non-invasive analysis tool for this task. Four commercially purchased ballistic glycerine soap blocks were used. Each had a single firearm discharged into it from a distance of approximately 15 cm using both gunshot and shotgun projectiles. After discharge, each block was imaged by a modern 16 slice multi-detector CT scanner and analysed using 3-D reconstruction software. Using the anterior-posterior and lateral scout views and the multi-plane reconstructed images, it was possible to visualize the temporary cavity, as well as the fragmentation and dispersal pattern of the projectiles, the distance travelled and angle of dispersal within the block of each projectile or fragment. A virtual cast of the temporary cavity can be also be made. Multi-detector CT with 3-D analysis software is shown to create a reliable permanent record of the projectile path allowing rapid analysis of different firearms and projectiles.

  2. iAK692: A genome-scale metabolic model of Spirulina platensis C1

    PubMed Central

    2012-01-01

    Background Spirulina (Arthrospira) platensis is a well-known filamentous cyanobacterium used in the production of many industrial products, including high value compounds, healthy food supplements, animal feeds, pharmaceuticals and cosmetics, for example. It has been increasingly studied around the world for scientific purposes, especially for its genome, biology, physiology, and also for the analysis of its small-scale metabolic network. However, the overall description of the metabolic and biotechnological capabilities of S. platensis requires the development of a whole cellular metabolism model. Recently, the S. platensis C1 (Arthrospira sp. PCC9438) genome sequence has become available, allowing systems-level studies of this commercial cyanobacterium. Results In this work, we present the genome-scale metabolic network analysis of S. platensis C1, iAK692, its topological properties, and its metabolic capabilities and functions. The network was reconstructed from the S. platensis C1 annotated genomic sequence using Pathway Tools software to generate a preliminary network. Then, manual curation was performed based on a collective knowledge base and a combination of genomic, biochemical, and physiological information. The genome-scale metabolic model consists of 692 genes, 837 metabolites, and 875 reactions. We validated iAK692 by conducting fermentation experiments and simulating the model under autotrophic, heterotrophic, and mixotrophic growth conditions using COBRA toolbox. The model predictions under these growth conditions were consistent with the experimental results. The iAK692 model was further used to predict the unique active reactions and essential genes for each growth condition. Additionally, the metabolic states of iAK692 during autotrophic and mixotrophic growths were described by phenotypic phase plane (PhPP) analysis. Conclusions This study proposes the first genome-scale model of S. platensis C1, iAK692, which is a predictive metabolic platform

  3. Application of an asymmetric flow field flow fractionation multi-detector approach for metallic engineered nanoparticle characterization--prospects and limitations demonstrated on Au nanoparticles.

    PubMed

    Hagendorfer, Harald; Kaegi, Ralf; Traber, Jacqueline; Mertens, Stijn F L; Scherrers, Roger; Ludwig, Christian; Ulrich, Andrea

    2011-11-14

    In this work we discuss about the method development, applicability and limitations of an asymmetric flow field flow fractionation (A4F) system in combination with a multi-detector setup consisting of UV/vis, light scattering, and inductively coupled plasma mass spectrometry (ICPMS). The overall aim was to obtain a size dependent-, element specific-, and quantitative method appropriate for the characterization of metallic engineered nanoparticle (ENP) dispersions. Thus, systematic investigations of crucial method parameters were performed by employing well characterized Au nanoparticles (Au-NPs) as a defined model system. For good separation performance, the A4F flow-, membrane-, and carrier conditions were optimized. To obtain reliable size information, the use of laser light scattering based detectors was evaluated, where an online dynamic light scattering (DLS) detector showed good results for the investigated Au-NP up to a size of 80 nm in hydrodynamic diameter. To adapt large sensitivity differences of the various detectors, as well as to guarantee long term stability and minimum contamination of the mass spectrometer a split-flow concept for coupling ICPMS was evaluated. To test for reliable quantification, the ICPMS signal response of ionic Au standards was compared to that of Au-NP. Using proper stabilization with surfactants, no difference for concentrations of 1-50 μg Au L(-1) in the size range from 5 to 80 nm for citrate stabilized dispersions was observed. However, studies using different A4F channel membranes showed unspecific particle-membrane interaction resulting in retention time shifts and unspecific loss of nanoparticles, depending on the Au-NP system as well as membrane batch and type. Thus, reliable quantification and discrimination of ionic and particular species was performed using ICPMS in combination with ultracentrifugation instead of direct quantification with the A4F multi-detector setup. Figures of merit were obtained, by comparing the

  4. Application of an asymmetric flow field flow fractionation multi-detector approach for metallic engineered nanoparticle characterization--prospects and limitations demonstrated on Au nanoparticles.

    PubMed

    Hagendorfer, Harald; Kaegi, Ralf; Traber, Jacqueline; Mertens, Stijn F L; Scherrers, Roger; Ludwig, Christian; Ulrich, Andrea

    2011-11-14

    In this work we discuss about the method development, applicability and limitations of an asymmetric flow field flow fractionation (A4F) system in combination with a multi-detector setup consisting of UV/vis, light scattering, and inductively coupled plasma mass spectrometry (ICPMS). The overall aim was to obtain a size dependent-, element specific-, and quantitative method appropriate for the characterization of metallic engineered nanoparticle (ENP) dispersions. Thus, systematic investigations of crucial method parameters were performed by employing well characterized Au nanoparticles (Au-NPs) as a defined model system. For good separation performance, the A4F flow-, membrane-, and carrier conditions were optimized. To obtain reliable size information, the use of laser light scattering based detectors was evaluated, where an online dynamic light scattering (DLS) detector showed good results for the investigated Au-NP up to a size of 80 nm in hydrodynamic diameter. To adapt large sensitivity differences of the various detectors, as well as to guarantee long term stability and minimum contamination of the mass spectrometer a split-flow concept for coupling ICPMS was evaluated. To test for reliable quantification, the ICPMS signal response of ionic Au standards was compared to that of Au-NP. Using proper stabilization with surfactants, no difference for concentrations of 1-50 μg Au L(-1) in the size range from 5 to 80 nm for citrate stabilized dispersions was observed. However, studies using different A4F channel membranes showed unspecific particle-membrane interaction resulting in retention time shifts and unspecific loss of nanoparticles, depending on the Au-NP system as well as membrane batch and type. Thus, reliable quantification and discrimination of ionic and particular species was performed using ICPMS in combination with ultracentrifugation instead of direct quantification with the A4F multi-detector setup. Figures of merit were obtained, by comparing the

  5. Computers and Computer Cultures.

    ERIC Educational Resources Information Center

    Papert, Seymour

    1981-01-01

    Instruction using computers is viewed as different from most other approaches to education, by allowing more than right or wrong answers, by providing models for systematic procedures, by shifting the boundary between formal and concrete processes, and by influencing the development of thinking in many new ways. (MP)

  6. Computed tomography imaging and angiography - principles.

    PubMed

    Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv

    2016-01-01

    The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology. PMID:27432657

  7. Computer Music

    NASA Astrophysics Data System (ADS)

    Cook, Perry R.

    This chapter covers algorithms, technologies, computer languages, and systems for computer music. Computer music involves the application of computers and other digital/electronic technologies to music composition, performance, theory, history, and the study of perception. The field combines digital signal processing, computational algorithms, computer languages, hardware and software systems, acoustics, psychoacoustics (low-level perception of sounds from the raw acoustic signal), and music cognition (higher-level perception of musical style, form, emotion, etc.).

  8. Accelerated glacier shrinkage in the Ak-Shyirak massif, Inner Tien Shan, during 2003-2013.

    PubMed

    Petrakov, Dmitry; Shpuntova, Alyona; Aleinikov, Alexandr; Kääb, Andreas; Kutuzov, Stanislav; Lavrentiev, Ivan; Stoffel, Markus; Tutubalina, Olga; Usubaliev, Ryskul

    2016-08-15

    The observed increase in summer temperatures and the related glacier downwasting has led to a noticeable decrease of frozen water resources in Central Asia, with possible future impacts on the economy of all downstream countries in the region. Glaciers in the Ak-Shyirak massif, located in the Inner Tien Shan, are not only affected by climate change, but also impacted by the open pit gold mining of the Kumtor Gold Company. In this study, glacier inventories referring to the years 2003 and 2013 were created for the Ak-Shyirak massif based on satellite imagery. The 193 glaciers had a total area of 351.2±5.6km(2) in 2013. Compared to 2003, the total glacier area decreased by 5.9±3.4%. During 2003-2013, the shrinkage rate of Ak-Shyirak glaciers was twice than that in 1977-2003 and similar to shrinkage rates in Tien Shan frontier ranges. We assessed glacier volume in 2013 using volume-area (VA) scaling and GlabTop modelling approaches. Resulting values for the whole massif differ strongly, the VA scaling derived volume is 30.0-26.4km(3) whereas the GlabTop derived volume accounts for 18.8-13.2km(3). Ice losses obtained from both approaches were compared to geodetically-derived volume change. VA scaling underestimates ice losses between 1943 and 2003 whereas GlabTop reveals a good match for eight glaciers for the period 2003-2012. In comparison to radio-echo soundings from three glaciers, the GlabTop model reveals a systematic underestimation of glacier thickness with a mean deviation of 16%. GlabTop tends to significantly underestimate ice thickness in accumulation areas, but tends to overestimate ice thickness in the lowermost parts of glacier snouts. Direct technogenic impact is responsible for about 7% of area and 5% of mass loss for glaciers in the Ak-Shyirak massif during 2003-2013. Therefore the increase of summer temperature seems to be the main driver of accelerated glacier shrinkage in the area. PMID:27100016

  9. Source mechanics for monochromatic icequakes produced during iceberg calving at Columbia Glacier, AK

    USGS Publications Warehouse

    O'Neel, Shad; Pfeffer, W.T.

    2007-01-01

    Seismograms recorded during iceberg calving contain information pertaining to source processes during calving events. However, locally variable material properties may cause signal distortions, known as site and path effects, which must be eliminated prior to commenting on source mechanics. We applied the technique of horizontal/vertical spectral ratios to passive seismic data collected at Columbia Glacier, AK, and found no dominant site or path effects. Rather, monochromatic waveforms generated by calving appear to result from source processes. We hypothesize that a fluid-filled crack source model offers a potential mechanism for observed seismograms produced by calving, and fracture-processes preceding calving.

  10. Computer Music

    NASA Astrophysics Data System (ADS)

    Cook, Perry

    This chapter covers algorithms, technologies, computer languages, and systems for computer music. Computer music involves the application of computers and other digital/electronic technologies to music composition, performance, theory, history, and perception. The field combines digital signal processing, computational algorithms, computer languages, hardware and software systems, acoustics, psychoacoustics (low-level perception of sounds from the raw acoustic signal), and music cognition (higher-level perception of musical style, form, emotion, etc.). Although most people would think that analog synthesizers and electronic music substantially predate the use of computers in music, many experiments and complete computer music systems were being constructed and used as early as the 1950s.

  11. A novel long noncoding RNA AK001796 acts as an oncogene and is involved in cell growth inhibition by resveratrol in lung cancer

    SciTech Connect

    Yang, Qiaoyuan; Xu, Enwu; Dai, Jiabin; Liu, Binbin; Han, Zhiyuan; Wu, Jianjun; Zhang, Shaozhu; Peng, Baoying; Zhang, Yajie; Jiang, Yiguo

    2015-06-01

    Lung cancer is the most common form of cancer throughout the world. The specific targeting of long noncoding RNAs (lncRNAs) by resveratrol opened a new avenue for cancer chemoprevention. In this study, we found that 21 lncRNAs were upregulated and 19 lncRNAs were downregulated in lung cancer A549 cells with 25 μmol/L resveratrol treatment determined by microarray analysis. AK001796, the lncRNA with the most clearly altered expression, was overexpressed in lung cancer tissues and cell lines, but its expression was downregulated in resveratrol-treated lung cancer cells. By monitoring cell proliferation and growth in vitro and tumor growth in vivo, we observed a significant reduction in cell viability in lung cancer cells and a slow growth in the tumorigenesis following AK001796 knockdown. We also found that AK001796 knockdown caused a cell-cycle arrest, with significant increases in the percentage of cells in G{sub 0}/G{sub 1} in lung cancer cells. By using cell cycle pathway-specific PCR arrays, we detected changes in a number of cell cycle-related genes related to lncRNA AK001796 knockdown. We further investigated whether AK001796 participated in the anticancer effect of resveratrol and the results showed that reduced lncRNA AK001796 level potentially impaired the inhibitory effect of resveratrol on cell proliferation. To our knowledge, this is the first study to report the changes in an lncRNA expression profile induced by resveratrol in lung cancer. - Highlights: • LncRNA AK001796 played an oncogenic role in lung carcinogenesis. • LncRNA AK001796 was downregulated in resveratrol-treated lung cancer cells. • LncRNA AK001796 was involved in the inhibition of cell growth by resveratrol.

  12. Cooling Computers.

    ERIC Educational Resources Information Center

    Birken, Marvin N.

    1967-01-01

    Numerous decisions must be made in the design of computer air conditioning, each determined by a combination of economics, physical, and esthetic characteristics, and computer requirements. Several computer air conditioning systems are analyzed--(1) underfloor supply and overhead return, (2) underfloor plenum and overhead supply with computer unit…

  13. Pygmalion's Computer.

    ERIC Educational Resources Information Center

    Peelle, Howard A.

    Computers have undoubtedly entered the educational arena, mainly in the areas of computer-assisted instruction (CAI) and artificial intelligence, but whether educators should embrace computers and exactly how they should use them are matters of great debate. The use of computers in support of educational administration is widely accepted.…

  14. 33 CFR 165.1712 - Safety Zones; Annual Independence Day Firework Displays, Skagway, Haines, and Wrangell, AK.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... regulations contained in 33 CFR 165.23, as well as the following regulations, apply. (2) No vessels, except... Day Firework Displays, Skagway, Haines, and Wrangell, AK. 165.1712 Section 165.1712 Navigation and... Areas Seventeenth Coast Guard District § 165.1712 Safety Zones; Annual Independence Day...

  15. 33 CFR 165.1712 - Safety Zones; Annual Independence Day Firework Displays, Skagway, Haines, and Wrangell, AK.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... regulations contained in 33 CFR 165.23, as well as the following regulations, apply. (2) No vessels, except... Day Firework Displays, Skagway, Haines, and Wrangell, AK. 165.1712 Section 165.1712 Navigation and... Areas Seventeenth Coast Guard District § 165.1712 Safety Zones; Annual Independence Day...

  16. 77 FR 1973 - Environmental Impact Statement: In the Vicinity of the City and Borough of Juneau, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-12

    ... Public Facilities, 6860 Glacier Highway, P.O. Box 112506, Juneau, Alaska 99811-2506; office hours 8:30 a... Juneau, AK AGENCY: Alaska Department of Transportation and Public Facilities (DOT&PF), Federal Highway... CONTACT: Mr. Tim Haugh, Environmental Program Manager, FHWA Alaska Division, P.O. Box 21648,...

  17. 78 FR 73109 - Radio Broadcasting Services; Benjamin and Cisco, TX; De Beque, CO; Port Lions, AK; Rule and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-05

    ... COMMISSION 47 CFR Part 73 Radio Broadcasting Services; Benjamin and Cisco, TX; De Beque, CO; Port Lions, AK... at De Beque, Colorado; Channel 237C3 at Benjamin, Texas; Channel 261C3 at Cisco, Texas; Channel 288C2..., Channel 237C3; by removing Cisco, Channel 261C3; by removing Channel 288C2 at Rule; and by...

  18. 78 FR 42036 - Radio Broadcasting Services; Port Lions, AK, De Beque, CO, Benjamin, Cisco, Rule, and Shamrock, TX

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-15

    ... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 73 Radio Broadcasting Services; Port Lions, AK, De Beque, CO, Benjamin, Cisco, Rule... 237C3; Cisco, Channel 261C3; Rule, Channel 288C2; and Shamrock, Channel 225C2. BILLING CODE 6712-01-P...

  19. 78 FR 7336 - Safety Zone; Alaska Marine Highway System Port Valdez Ferry Terminal, Port Valdez; Valdez, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-01

    ... of Acronyms DHS Department of Homeland Security FR Federal Register NPRM Notice of Proposed... Federal Register (73 FR 3316). 4. Public Meeting We do not now plan to hold a public meeting. But you may... Ferry Terminal, Port Valdez; Valdez, AK AGENCY: Coast Guard, DHS. ACTION: Notice of Proposed...

  20. Using macroalgal δ15N bioassay to detect cruise ship waste water effluent inputs in Skagway, AK

    EPA Science Inventory

    Nitrogen stable isotopes are a powerful tool for tracking sources of N to marine ecosystems. I used green macroalgae as a bioassay organism to evaluate if the δ15N signature of cruise ship waste water effluent (CSWWE) could be detected in Skagway Harbor, AK. Opportunistic green...

  1. 76 FR 36157 - In the Matter of Alaska Industrial X-Ray, Inc., Anchorage, AK; Confirmatory Order Modifying...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-21

    ... Alaska Industrial X-Ray, Inc., Anchorage, AK; Confirmatory Order Modifying License; Effective Immediately I Alaska Industrial X-Ray, Inc. (AIX or Licensee) is the holder of Materials License 50-16084-01... Industrial X-Ray, Inc. (AIX) and the Nuclear Regulatory Commission (NRC) relating to the NRC's letter...

  2. 77 FR 10711 - Safety Zone; KULLUK, Outer Continental Shelf Mobile Offshore Drilling Unit (MODU), Beaufort Sea, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-23

    ... Offshore Drilling Unit (MODU), Beaufort Sea, AK AGENCY: Coast Guard, DHS. ACTION: Notice of proposed... identified lease blocks will be conducted with the KULLUK. The KULLUK is a true Mobile Offshore Drilling Unit... Offshore Drilling Unit (MODU), Beaufort Sea, Alaska. (a) Description. The KULLUK will be engaged...

  3. Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Lowrey, Nikki M.; Mitchell, Mark A.

    2016-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon the solvent AsahiKlin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

  4. 75 FR 12976 - Amendment of Restricted Area R-2204 High and R-2204 Low; Oliktok Point, AK

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ..., until they are no longer needed by the Department of Energy (DOE). Continued access to R-2204 High and R-2204 Low at Oliktok, AK, is required for current moored balloon and future climate-related aviation... rulemaking to amend Restricted Area R-2204 High and R-2204 Low in Alaska (74 FR 61291). Interested...

  5. Detection of Sharp Symmetric Features in the Circumbinary Disk around AK Sco

    NASA Astrophysics Data System (ADS)

    Janson, Markus; Thalmann, Christian; Boccaletti, Anthony; Maire, Anne-Lise; Zurlo, Alice; Marzari, Francesco; Meyer, Michael R.; Carson, Joseph C.; Augereau, Jean-Charles; Garufi, Antonio; Henning, Thomas; Desidera, Silvano; Asensio-Torres, Ruben; Pohl, Adriana

    2016-01-01

    The Search for Planets Orbiting Two Stars survey aims to study the formation and distribution of planets in binary systems by detecting and characterizing circumbinary planets and their formation environments through direct imaging. With the SPHERE Extreme Adaptive Optics instrument, a good contrast can be achieved even at small (<300 mas) separations from bright stars, which enables studies of planets and disks in a separation range that was previously inaccessible. Here, we report the discovery of resolved scattered light emission from the circumbinary disk around the well-studied young double star AK Sco, at projected separations in the ˜13-40 AU range. The sharp morphology of the imaged feature is surprising, given the smooth appearance of the disk in its spectral energy distribution. We show that the observed morphology can be represented either as a highly eccentric ring around AK Sco, or as two separate spiral arms in the disk, wound in opposite directions. The relative merits of these interpretations are discussed, as well as whether these features may have been caused by one or several circumbinary planets interacting with the disk. Based on observations collected at the European Southern Observatory, Chile, under observing program 095.C-0346(B).

  6. Detection of Sharp Symmetric Features in the Circumbinary Disk around AK Sco

    NASA Astrophysics Data System (ADS)

    Janson, Markus; Thalmann, Christian; Boccaletti, Anthony; Maire, Anne-Lise; Zurlo, Alice; Marzari, Francesco; Meyer, Michael R.; Carson, Joseph C.; Augereau, Jean-Charles; Garufi, Antonio; Henning, Thomas; Desidera, Silvano; Asensio-Torres, Ruben; Pohl, Adriana

    2016-01-01

    The Search for Planets Orbiting Two Stars survey aims to study the formation and distribution of planets in binary systems by detecting and characterizing circumbinary planets and their formation environments through direct imaging. With the SPHERE Extreme Adaptive Optics instrument, a good contrast can be achieved even at small (<300 mas) separations from bright stars, which enables studies of planets and disks in a separation range that was previously inaccessible. Here, we report the discovery of resolved scattered light emission from the circumbinary disk around the well-studied young double star AK Sco, at projected separations in the ∼13–40 AU range. The sharp morphology of the imaged feature is surprising, given the smooth appearance of the disk in its spectral energy distribution. We show that the observed morphology can be represented either as a highly eccentric ring around AK Sco, or as two separate spiral arms in the disk, wound in opposite directions. The relative merits of these interpretations are discussed, as well as whether these features may have been caused by one or several circumbinary planets interacting with the disk. Based on observations collected at the European Southern Observatory, Chile, under observing program 095.C-0346(B).

  7. A Disk-based Dynamical Mass Estimate for the Young Binary AK Sco

    NASA Astrophysics Data System (ADS)

    Czekala, I.; Andrews, S. M.; Jensen, E. L. N.; Stassun, K. G.; Torres, G.; Wilner, D. J.

    2015-06-01

    We present spatially and spectrally resolved Atacama Large Millimeter/submillimeter Array (ALMA) observations of gas and dust in the disk orbiting the pre-main sequence (pre-MS) binary AK Sco. By forward-modeling the disk velocity field traced by CO J = 2-1 line emission, we infer the mass of the central binary, {M}*=2.49+/- 0.10 {M}⊙ , a new dynamical measurement that is independent of stellar evolutionary models. Assuming the disk and binary are co-planar within ˜2°, this disk-based binary mass measurement is in excellent agreement with constraints from radial velocity monitoring of the combined stellar spectra. These ALMA results are also compared with the standard approach of estimating masses from the location of the binary in the Hertzsprung-Russell diagram, using several common pre-MS model grids. These models predict stellar masses that are marginally consistent with our dynamical measurement (at ˜2σ), but are systematically high (by ˜10%). These same models consistently predict an age of 18 ± 1 Myr for AK Sco, in line with its membership in the Upper Centaurus-Lupus association but surprisingly old for it to still host a gas-rich disk. As ALMA accumulates comparable data for large samples of pre-MS stars, the methodology employed here to extract a dynamical mass from the disk rotation curve should prove extraordinarily useful for efforts to characterize the fundamental parameters of early stellar evolution.

  8. Strain-dependent occurrence of functional GTP:AMP phosphotransferase (AK3) in Saccharomyces cerevisiae.

    PubMed

    Schricker, R; Magdolen, V; Strobel, G; Bogengruber, E; Breitenbach, M; Bandlow, W

    1995-12-29

    The gene for yeast GTP:AMP phosphotransferase (PAK3) was found to encode a nonfunctional protein in 10 laboratory strains and one brewers' strain. The protein product showed high similarity to vertebrate AK3 and was located exclusively in the mitochondrial matrix. The deduced amino acid sequence revealed a protein that was shorter at the carboxyl terminus than all other known adenylate kinases. Introduction of a +1 frameshift into the 3'-terminal region of the gene extended homology of the deduced amino acid sequence to other members of the adenylate kinase family including vertebrate AK3. Frameshift mutations obtained after in vitro and in vivo mutagenesis were capable of complementing the adk1 temperature-conditional deficiency in Escherichia coli, indicating that the frameshift led to the expression of a protein that could phosphorylate AMP. Some yeasts, however, including strain D273-10B, two wine yeasts, and two more distantly related yeast genera, harbored an active allele, named AKY3, which contained a +1 frameshift close to the carboxyl terminus as compared with the laboratory strains. The encoded protein exhibited GTP:AMP and ITP:AMP phosphotransferase activities but did not accept ATP as phosphate donor. Although single copy in the haploid genome, disruption of the AKY3 allele displayed no phenotype, excluding the possibility that laboratory and brewers' strains had collected second site suppressors. It must be concluded that yeast mitochondria can completely dispense with GTP:AMP phosphotransferase activity.

  9. Characterization of a GHF45 cellulase, AkEG21, from the common sea hare Aplysia kurodai

    NASA Astrophysics Data System (ADS)

    Rahman, Mohammad; Inoue, Akira; Ojima, Takao

    2014-08-01

    The common sea hare Aplysia kurodai is known to be a good source for the enzymes degrading seaweed polysaccharides. Recently four cellulases, i.e., 95 kDa, 66 kDa, 45 kDa and 21 kDa enzymes, were isolated from A. kurodai (Tsuji et al., PLoS ONE, 8, e65418, 2013). The former three cellulases were regarded as glycosyl-hydrolase-family 9 (GHF9) enzymes, while the 21 kDa cellulase was suggested to be a GHF45 enzyme. The 21 kDa cellulase was significantly heat stable, and appeared to be advantageous in performing heterogeneous expression and protein-engineering study. In the present study, we determined some enzymatic properties of the 21 kDa cellulase and cloned its cDNA to provide the basis for the protein engineering study of this cellulase. The purified 21 kDa enzyme, termed AkEG21 in the present study, hydrolyzed carboxymethyl cellulose with an optimal pH and temperature at 4.5 and 40oC, respectively. AkEG21 was considerably heat-stable, i.e., it was not inactivated by the incubation at 55oC for 30 min. AkEG21 degraded phosphoric-acid-swollen cellulose producing cellotriose and cellobiose as major end products but hardly degraded oligosaccharides smaller than tetrasaccharide. This indicated that AkEG21 is an endolytic ?-1,4-glucanase (EC 3.2.1.4). A cDNA of 1,013 bp encoding AkEG21 was amplified by PCR and the amino-acid sequence of 197 residues was deduced. The sequence comprised the initiation Met, the putative signal peptide of 16 residues for secretion and the catalytic domain of 180 residues, which lined from the N-terminus in this order. The sequence of the catalytic domain showed 47-62% amino-acid identities to those of GHF45 cellulases reported in other mollusks. Both the catalytic residues and the N-glycosylation residues known in other GHF45 cellulases were conserved in AkEG21. Phylogenetic analysis for the amino-acid sequences suggested the close relation between AkEG21 and fungal GHF45 cellulases.

  10. Characterization of a GHF45 cellulase, AkEG21, from the common sea hare Aplysia kurodai

    PubMed Central

    Rahman, Mohammad M.; Inoue, Akira; Ojima, Takao

    2014-01-01

    The common sea hare Aplysia kurodai is known to be a good source for the enzymes degrading seaweed polysaccharides. Recently four cellulases, i.e., 95, 66, 45, and 21 kDa enzymes, were isolated from A. kurodai (Tsuji et al., 2013). The former three cellulases were regarded as glycosyl-hydrolase-family 9 (GHF9) enzymes, while the 21 kDa cellulase was suggested to be a GHF45 enzyme. The 21 kDa cellulase was significantly heat stable, and appeared to be advantageous in performing heterogeneous expression and protein-engineering study. In the present study, we determined some enzymatic properties of the 21 kDa cellulase and cloned its cDNA to provide the basis for the protein engineering study of this cellulase. The purified 21 kDa enzyme, termed AkEG21 in the present study, hydrolyzed carboxymethyl cellulose with an optimal pH and temperature at 4.5 and 40°C, respectively. AkEG21 was considerably heat-stable, i.e., it was not inactivated by the incubation at 55°C for 30 min. AkEG21 degraded phosphoric-acid-swollen cellulose producing cellotriose and cellobiose as major end products but hardly degraded oligosaccharides smaller than tetrasaccharide. This indicated that AkEG21 is an endolytic β-1,4-glucanase (EC 3.2.1.4). A cDNA of 1013 bp encoding AkEG21 was amplified by PCR and the amino-acid sequence of 197 residues was deduced. The sequence comprised the initiation Met, the putative signal peptide of 16 residues for secretion and the catalytic domain of 180 residues, which lined from the N-terminus in this order. The sequence of the catalytic domain showed 47–62% amino-acid identities to those of GHF45 cellulases reported in other mollusks. Both the catalytic residues and the N-glycosylation residues known in other GHF45 cellulases were conserved in AkEG21. Phylogenetic analysis for the amino-acid sequences suggested the close relation between AkEG21 and fungal GHF45 cellulases. PMID:25147784

  11. A method to analyse observer disagreement in visual grading studies: example of assessed image quality in paediatric cerebral multidetector CT images.

    PubMed

    Ledenius, K; Svensson, E; Stålhammar, F; Wiklund, L-M; Thilander-Klang, A

    2010-07-01

    The purpose was to demonstrate a non-parametric statistical method that can identify and explain the components of observer disagreement in terms of systematic disagreement as well as additional individual variability, in visual grading studies. As an example, the method was applied to a study where the effect of reduced tube current on diagnostic image quality in paediatric cerebral multidetector CT (MDCT) images was investigated. Quantum noise, representing dose reductions equivalent to steps of 20 mA, was artificially added to the raw data of 25 retrospectively selected paediatric cerebral MDCT examinations. Three radiologists, blindly and randomly, assessed the resulting images from two different levels of the brain with regard to the reproduction of high- and low-contrast structures and overall image quality. Images from three patients were assessed twice for the analysis of intra-observer disagreement. The intra-observer disagreement in test-retest assessments could mainly be explained by a systematic change towards lower image quality the second time the image was reviewed. The inter-observer comparisons showed that the paediatric radiologist was more critical of the overall image quality, while the neuroradiologists were more critical of the reproduction of the basal ganglia. Differences between the radiologists regarding the extent to which they used the whole classification scale were also found. The statistical method used was able to identify and separately measure a presence of bias apart from additional individual variability within and between the radiologists which is, at the time of writing, not attainable by any other statistical approach suitable for paired, ordinal data.

  12. Liver injury diagnosed on computed tomography after use of an automated cardiopulmonary resuscitation device.

    PubMed

    Camden, Jeremy R; Carucci, Laura R

    2011-10-01

    We report a case of an 89-year-old female with active extravasation and hemoperitoneum from a liver laceration demonstrated on multidetector computed tomography (CT), attributed to the use of an automated mechanical cardiopulmonary resuscitation (CPR) device. Although iatrogenic internal injuries related to manual CPR and CPR devices have previously been reported [1, 2], there has been no reported CT evidence of liver injury related to automated CPR devices to the authors' knowledge. Imaging findings of complications related to the use of automated CPR devices are important to recognize and also help explain the possible mechanisms of injury. Liver injuries with active bleeding following CPR may have devastating consequences related to hemodynamic instability and may have an increased incidence when CPR is performed using an automated chest compression device.

  13. Usefulness and limitations of postmortem computed tomography in forensic analysis of gunshot injuries: Three case reports.

    PubMed

    Usui, Akihito; Kawasumi, Yusuke; Hosokai, Yoshiyuki; Kozakai, Masataka; Saito, Haruo; Funayama, Masato

    2016-01-01

    Gunshot injury has always been an important field of investigation in postmortem forensic radiology. The localization and retrieval of the bullet and of potentially important fragments are vital to these cases. Using postmortem multidetector-row computed tomography (MDCT) prior to forensic autopsy, we sought to illustrate the importance of this modality in the noninvasive characterization of gunshot wounds. We obtained and analyzed MDCT images in three cases of gunshot wounds (accidental close-range shotgun shooting, suicidal contact gunshot to the head and accidental long-range buckshot shooting). We discuss the value of postmortem MDCT findings in gunshot wound cases by comparing with forensic autopsy findings in Japan, a developing country with miserably low autopsy rate. PMID:26832386

  14. Computational dosimetry

    SciTech Connect

    Siebert, B.R.L.; Thomas, R.H.

    1996-01-01

    The paper presents a definition of the term ``Computational Dosimetry`` that is interpreted as the sub-discipline of computational physics which is devoted to radiation metrology. It is shown that computational dosimetry is more than a mere collection of computational methods. Computational simulations directed at basic understanding and modelling are important tools provided by computational dosimetry, while another very important application is the support that it can give to the design, optimization and analysis of experiments. However, the primary task of computational dosimetry is to reduce the variance in the determination of absorbed dose (and its related quantities), for example in the disciplines of radiological protection and radiation therapy. In this paper emphasis is given to the discussion of potential pitfalls in the applications of computational dosimetry and recommendations are given for their avoidance. The need for comparison of calculated and experimental data whenever possible is strongly stressed.

  15. Computer Recreations.

    ERIC Educational Resources Information Center

    Dewdney, A. K.

    1989-01-01

    Reviews the performance of computer programs for writing poetry and prose, including MARK V. SHANEY, MELL, POETRY GENERATOR, THUNDER THOUGHT, and ORPHEUS. Discusses the writing principles of the programs. Provides additional information on computer magnification techniques. (YP)

  16. Computational Toxicology

    EPA Science Inventory

    Computational toxicology’ is a broad term that encompasses all manner of computer-facilitated informatics, data-mining, and modeling endeavors in relation to toxicology, including exposure modeling, physiologically based pharmacokinetic (PBPK) modeling, dose-response modeling, ...

  17. Female Computer

    NASA Technical Reports Server (NTRS)

    1964-01-01

    Melba Roy heads the group of NASA mathematicians, known as 'computers,' who track the Echo satellites. Roy's computations help produce the orbital element timetables by which millions can view the satellite from Earth as it passes overhead.

  18. Cloud Computing

    SciTech Connect

    Pete Beckman and Ian Foster

    2009-12-04

    Chicago Matters: Beyond Burnham (WTTW). Chicago has become a world center of "cloud computing." Argonne experts Pete Beckman and Ian Foster explain what "cloud computing" is and how you probably already use it on a daily basis.

  19. Quantum computing

    PubMed Central

    Li, Shu-Shen; Long, Gui-Lu; Bai, Feng-Shan; Feng, Song-Lin; Zheng, Hou-Zhi

    2001-01-01

    Quantum computing is a quickly growing research field. This article introduces the basic concepts of quantum computing, recent developments in quantum searching, and decoherence in a possible quantum dot realization. PMID:11562459

  20. Computer Algebra.

    ERIC Educational Resources Information Center

    Pavelle, Richard; And Others

    1981-01-01

    Describes the nature and use of computer algebra and its applications to various physical sciences. Includes diagrams illustrating, among others, a computer algebra system and flow chart of operation of the Euclidean algorithm. (SK)

  1. Computer Ease.

    ERIC Educational Resources Information Center

    Drenning, Susan; Getz, Lou

    1992-01-01

    Computer Ease is an intergenerational program designed to put an Ohio elementary school's computer lab, software library, staff, and students at the disposal of older adults desiring to become computer literate. Three 90-minute instructional sessions allow seniors to experience 1-to-1 high-tech instruction by enthusiastic, nonthreatening…

  2. Parallel computers

    SciTech Connect

    Treveaven, P.

    1989-01-01

    This book presents an introduction to object-oriented, functional, and logic parallel computing on which the fifth generation of computer systems will be based. Coverage includes concepts for parallel computing languages, a parallel object-oriented system (DOOM) and its language (POOL), an object-oriented multilevel VLSI simulator using POOL, and implementation of lazy functional languages on parallel architectures.

  3. Computer Manual.

    ERIC Educational Resources Information Center

    Illinois State Office of Education, Springfield.

    This manual designed to provide the teacher with methods of understanding the computer and its potential in the classroom includes four units with exercises and an answer sheet. Unit 1 covers computer fundamentals, the mini computer, programming languages, an introduction to BASIC, and control instructions. Variable names and constants described…

  4. Computer Literacy.

    ERIC Educational Resources Information Center

    San Marcos Unified School District, CA.

    THE FOLLOWING IS THE FULL TEXT OF THIS DOCUMENT: After viewing many computer-literacy programs, we believe San Marcos Junior High School has developed a unique program which will truly develop computer literacy. Our hope is to give all students a comprehensive look at computers as they go through their two years here. They will not only learn the…

  5. Autophosphorylation at Thr279 of Entamoeba histolytica atypical kinase EhAK1 is required for activity and regulation of erythrophagocytosis

    PubMed Central

    Mansuri, M Shahid; Babuta, Mrigya; Ali, Mohammad Sabir; Bharadwaj, Ravi; jhingan, Gagan Deep; Gourinath, Samudrala; Bhattacharya, Sudha; Bhattacharya, Alok

    2016-01-01

    Phagocytosis plays a key role in survival and pathogenicity of Entamoeba histolytica. We have recently demonstrated that an atypical kinase EhAK1 is involved in phagocytosis in this parasite. It is recruited to the phagocytic cups through interaction with EhCaBP1. EhAK1 manipulates actin dynamics by multiple mechanisms including phosphorylation of G-actin. Biochemical analysis showed that EhAK1 is a serine/threonine kinase with broad ion specificity and undergoes multiple trans-autophosphorylation. Three autophosphorylation sites were identified by mass spectrometry. Out of these Thr279 appears to be involved in both autophosphorylation as well as substrate phosphorylation. Over expression of the mutant Thr279A inhibited erythrophagocytosis showing dominant negative phenotype. Multiple alignments of different kinases including alpha kinases displayed conserved binding sites that are thought to be important for function of the protein. Mutation studies demonstrated the importance of some of these binding sites in kinase activity. Binding studies with fluorescent-ATP analogs supported our prediction regarding ATP binding site based on sequence alignment. In conclusion, EhAK1 has multiple regulatory features and enrichment of EhAK1 at the site of phagocytosis stimulates trans-autophosphorylation reaction that increases kinase activity resulting in enhanced actin dynamics and phagocytosis. Some of the properties of EhAK1 are similar to that seen in alpha kinases. PMID:26739245

  6. Loss of kinase activity in a patient with Wolcott-Rallison syndrome caused by a novel mutation in the EIF2AK3 gene.

    PubMed

    Biason-Lauber, Anna; Lang-Muritano, Mariarosaria; Vaccaro, Tindara; Schoenle, Eugen J

    2002-07-01

    Wolcott-Rallison syndrome (WRS) is an autosomal recessive disorder characterized by neonatal or early infancy type 1 diabetes, epiphyseal dysplasia, and growth retardation. Mutations in the EIF2AK3 gene, encoding the eukaryotic initiation factor 2alpha-kinase 3 (EIF2AK3), have been found in WRS patients. Here we describe a girl who came to our attention at 2 months of age with severe hypertonic dehydration and diabetic ketoacidosis. A diagnosis of type 1 diabetes was made and insulin treatment initiated. Growth retardation and microcephaly were also present. Anti-islet cell autoantibodies were negative, and mitochondrial diabetes was excluded. Imaging revealed a hypoplastic pancreas and typical signs of spondylo-epiphyseal dysplasia. The diagnosis of WRS was therefore made at age 5 years. Sequencing analysis of her EIF2AK3 gene revealed the presence of a homozygous T to C exchange in exon 13 leading to the missense serine 877 proline mutation. The mutated kinase, although it partly retains the ability of autophosphorylation, is unable to phosphorylate its natural substrate, eukaryotic initiation factor 2alpha (eIF2alpha). This is the first case in which the pathophysiological role of EIF2AK3 deficiency in WRS is confirmed at the molecular level. Our data demonstrate that EIF2AK3 kinase activity is essential for pancreas islet function and bone development in humans, and we suggest EIF2AK3 as a possible target for therapeutic intervention in diabetes. PMID:12086964

  7. Salt bridge residues between I-Ak dimer of dimers alpha-chains modulate antigen presentation.

    PubMed

    Yadati, S; Nydam, T; Demian, D; Wade, T K; Gabriel, J L; Barisas, B G; Wade, W F

    1999-03-15

    Class II dimers of dimers are predicted to have functional significance in antigen presentation. The putative contact amino acids of the I-Ak class II dimer of dimers have been identified by molecular modeling based on the DR1 crystal structure (Nydam et al., Int. Immunol. 10, 1237,1998). We have previously reported the role in antigen presentation of dimer of dimers contact amino acids located in the C-terminal domains of the alpha- and beta-chains of class II. Our calculations show that residues Ealpha89 and Ralpha145 in the alpha2-domain form an inter alpha-chain salt bridge between pairs of alphabeta-heterodimers. Other residues, Qalpha92 and Nalpha115, may be involved in close association in that part of the alpha-chain. We investigated the role of these amino acids on class II expression and antigen presentation. Class II composed of an Ealpha89K substituted alpha-chain paired with a wt beta-chain exhibited inhibited antigen presentation and expression of alpha-chain serologic epitopes. In contrast, mutation of Ralpha145E had less affect on antigen presentation and did not affect I-Ak serologic epitopes. Interchanging charges of the salt bridge residues by expressing both Ralpha145E and Ealpha89K on the same chain obviated the large negative effect of the Ealpha89K mutation on antigen presentation but not on the serologic epitopes. Our results are similar for those reported for mutation of DR3's inter-chain salt bridge with the exception that double mutants did not moderate the DR3 defect. Interestingly, the amino acids differences between I-A and DR change the location of the inter-chain salt bridges. In DR1 these residues are located at positions Ealpha88 and Kalpha111; in I-Ak these residues are located at position Ealpha89 and Ralpha145. Inter alpha-chain salt bridges are thus maintained in various class II molecules by amino acids located in different parts of the alpha2-domain. This conservation of structure suggests that considerable functional

  8. AK Sco: evidence of tide driven filling of the inner gap in the circumbinary disk

    NASA Astrophysics Data System (ADS)

    Gomez de Castro, Ana I.; Lopez-Santiago, Javier; Talavera, Antonio; Sytov, A. Yu.; Bisikalo, Dmitri

    2013-07-01

    AK Sco stands out among pre-main sequence binaries because of its prominent ultraviolet excess, the high eccentricity of its orbit and the strong tides driven by it. AK Sco is made of two F5 type stars that get as close as 11R* at periastron passage. The presence of a dense (ne ~ 1011 cm-3) extended envelope has been unveiled recently. In this article, we report the results from a XMM-Newton based, monitoring of the system. We show that at periastron, X-ray and UV fluxes are enhanced by a factor of ~3 with respect to the apastron values. The X-ray radiation is produced in an optically thin plasma with T~6.4 MK and it is found that the NH column rises from 0.35 1021 cm-2 at periastron to 1.11 1021 cm-2 at apastron, in good agreement with previous polarimetric observations. The UV emission detected in the OM band seems to be caused by the reprocessing of the high energy magnetospheric radiation on the circumstellar material. Moreover, further evidence of the strong magnetospheric disturbances is provided by the detection of line broadening of 279 km s-1 in the N V line with HST/STIS. Numerical simulations of the mass flow from the circumbinary disk to the components have been carried out. They provide a consistent scenario to interpret AK Sco observations. We show that the eccentric orbit acts like a gravitational piston. At apastron, matter is dragged efficiently from the inner disk border, filling the inner gap and producing accretion streams that end as ring-like structures around each component of the system. At periastron, the ring-like structures get in contact, leading to angular momentum annihilation, and thus producing an accretion outburst. These results are published in Gómez de Castro et al. 2013, ApJ, 766, 62 We have also discovered a 780 s period oscillation in the UV continuum light curve triggered at periastron passage (Gómez de Castro, Lopez-Santiago & Talavera, 2013, MNRAS, 429, L1).

  9. Development of adaptive noise reduction filter algorithm for pediatric body images in a multi-detector CT

    NASA Astrophysics Data System (ADS)

    Nishimaru, Eiji; Ichikawa, Katsuhiro; Okita, Izumi; Ninomiya, Yuuji; Tomoshige, Yukihiro; Kurokawa, Takehiro; Ono, Yutaka; Nakamura, Yuko; Suzuki, Masayuki

    2008-03-01

    Recently, several kinds of post-processing image filters which reduce the noise of computed tomography (CT) images have been proposed. However, these image filters are mostly for adults. Because these are not very effective in small (< 20 cm) display fields of view (FOV), we cannot use them for pediatric body images (e.g., premature babies and infant children). We have developed a new noise reduction filter algorithm for pediatric body CT images. This algorithm is based on a 3D post-processing in which the output pixel values are calculated by nonlinear interpolation in z-directions on original volumetric-data-sets. This algorithm does not need the in-plane (axial plane) processing, so the spatial resolution does not change. From the phantom studies, our algorithm could reduce SD up to 40% without affecting the spatial resolution of x-y plane and z-axis, and improved the CNR up to 30%. This newly developed filter algorithm will be useful for the diagnosis and radiation dose reduction of the pediatric body CT images.

  10. Computer software.

    PubMed

    Rosenthal, L E

    1986-10-01

    Software is the component in a computer system that permits the hardware to perform the various functions that a computer system is capable of doing. The history of software and its development can be traced to the early nineteenth century. All computer systems are designed to utilize the "stored program concept" as first developed by Charles Babbage in the 1850s. The concept was lost until the mid-1940s, when modern computers made their appearance. Today, because of the complex and myriad tasks that a computer system can perform, there has been a differentiation of types of software. There is software designed to perform specific business applications. There is software that controls the overall operation of a computer system. And there is software that is designed to carry out specialized tasks. Regardless of types, software is the most critical component of any computer system. Without it, all one has is a collection of circuits, transistors, and silicone chips.

  11. Computer sciences

    NASA Technical Reports Server (NTRS)

    Smith, Paul H.

    1988-01-01

    The Computer Science Program provides advanced concepts, techniques, system architectures, algorithms, and software for both space and aeronautics information sciences and computer systems. The overall goal is to provide the technical foundation within NASA for the advancement of computing technology in aerospace applications. The research program is improving the state of knowledge of fundamental aerospace computing principles and advancing computing technology in space applications such as software engineering and information extraction from data collected by scientific instruments in space. The program includes the development of special algorithms and techniques to exploit the computing power provided by high performance parallel processors and special purpose architectures. Research is being conducted in the fundamentals of data base logic and improvement techniques for producing reliable computing systems.

  12. Pulmonary Perfused Blood Volume with Dual-Energy CT as Surrogate for Pulmonary Perfusion Assessed with Dynamic Multidetector CT

    PubMed Central

    Fuld, Matthew K.; Halaweish, Ahmed F.; Haynes, Susan E.; Divekar, Abhay A.; Guo, Junfeng

    2013-01-01

    Purpose: To compare measurements of regional pulmonary perfused blood volume (PBV) and pulmonary blood flow (PBF) obtained with computed tomography (CT) in two pig models. Materials and Methods: The institutional animal care and use committee approved all animal studies. CT-derived PBF and PBV were determined in four anesthetized, mechanically ventilated, supine swine by using two methods for creating pulmonary parenchymal perfusion heterogeneity. Two animals were examined after sequentially moving a pulmonary arterial balloon catheter from a distal to a central location, and two others were examined over a range of static airway pressures, which varied the extents of regional PBF. Lung sections were divided into blocks and Pearson correlation coefficients calculated to compare matching regions between the two methods. Results: CT-derived PBF, CT-derived PBV, and their associated coefficients of variation (CV) were closely correlated on a region-by-region basis in both the balloon occlusion (Pearson R = 0.91 and 0.73 for animals 1 and 2, respectively; Pearson R = 0.98 and 0.87 for comparison of normalized mean and CV for animals 1 and 2, respectively) and lung inflation studies (Pearson R = 0.94 and 0.74 for animals 3 and 4, respectively; Pearson R = 0.94 and 0.69 for normalized mean and CV for animals 3 and 4, respectively). When accounting for region-based effects, correlations remained highly significant at the P < .001 level. Conclusion: CT-derived PBV heterogeneity is a suitable surrogate for CT-derived PBF heterogeneity. ©RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112789/-/DC1 PMID:23192773

  13. Computer Literacy: Teaching Computer Ethics.

    ERIC Educational Resources Information Center

    Troutner, Joanne

    1986-01-01

    Suggests learning activities for teaching computer ethics in three areas: (1) equal access; (2) computer crime; and (3) privacy. Topics include computer time, advertising, class enrollments, copyright law, sabotage ("worms"), the Privacy Act of 1974 and the Freedom of Information Act of 1966. (JM)

  14. Assessment of AK (Above Knee) Prosthesis with Different Ankle Assembly Using GRF Pattern in Stance Phase

    NASA Astrophysics Data System (ADS)

    Kim, Sung-Min; Kim, Sung-Jae; Bae, Ha-Suk

    In this study, ground reaction force (GRF), absolute symmetry index (ASI) and coefficient of variation (CV) of fixed, single-axis and multi-axis prosthetic ankle assemblies were investigated by biomechanical evaluation of above knee amputees. In the experiments, 37 normal male volunteers, two male and two female Above Knee (AK) amputees GRF data were tested with fixed, single-axis and multi-axis prosthetic ankle assembly. A gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance phase for ten points. The results showed that fixed-axis ankle assembly was superior to other two ankle assemblies for forwarding and braking forces. Multi-axis ankle was relatively superior to other two ankle assemblies for gait balancing and movement of the mass center. Single-axis ankle was relatively superior to the other two ankle assemblies for CV and ASI of GRF.

  15. Tectonic geomorphology of a large normal fault: Akşehir fault, SW Turkey

    NASA Astrophysics Data System (ADS)

    Topal, Savaş; Keller, Edward; Bufe, Aaron; Koçyiğit, Ali

    2016-04-01

    In order to better understand the activity of the Akşehir normal fault in SW Turkey and the associated seismic hazard, we investigated the tectonic geomorphology of a 60-km stretch of the 100-km-long Akşehir fault block. The fault can be separated into seven geomorphic segments (1 to 7 from NW to SE) along the mountain front. Segment length varies from about 9 to 14 km, and relief of the horst block varies from about 0.6 km in the SE to 1.0 km in the NW. Analysis of the tectonic geomorphology of 32 drainage basins and mountain front facets using a combination of geomorphic indices reveals a general pattern of high slip rates in the northern and central segments and low slip rates in the southern, probably older, segments. We show that mountain front sinuosity varies from about 1.1 to 1.4 on segments S1-S6 to 2.4 on segment S7, suggesting that the six northern segments are more active than the southernmost segment. Similarly, χ analysis and slope-area analysis of streams reveal a pattern of steepest channels draining the central and northern segments of the horst. The ratio of valley floor width to valley height varies from 0.2 to 0.6, which are typical values for tectonically active mountain fronts; and alluvial fans along segments S1, S2, and S4 are back-tilted. Finally, we show that (1) shapes of the ~ 100-900m high mountain front facets are mostly triangular (~ 80%) and partly trapezoidal (~ 20%); (2) facet slopes range from 6 to 22°; (3) facets at the NW and SE segment ends are larger than the intervening facets; and (4) steepest facets occur along the central segments. Uplift rates estimated from the slope of mountain front facets range from about 0.06 m/ky on the southernmost fault segment (S7) to 0.23 m/ky on the more central S5 and 0.16 m/ky on the northern segment (S1). The estimated pattern of uplift is consistent with the pattern of geomorphic indices. The vertical relief of the facets suggests that uplift of the mountain front initiated in the late

  16. Neurotransmitter receptor density changes in Pitx3ak mice--a model relevant to Parkinson's disease.

    PubMed

    Cremer, J N; Amunts, K; Graw, J; Piel, M; Rösch, F; Zilles, K

    2015-01-29

    Parkinson's disease (PD) is the second most common neurodegenerative disorder, characterized by alterations of nigrostriatal dopaminergic neurotransmission. Compared to the wealth of data on the impairment of the dopamine system, relatively limited evidence is available concerning the role of major non-dopaminergic neurotransmitter systems in PD. Therefore, we comprehensively investigated the density and distribution of neurotransmitter receptors for glutamate, GABA, acetylcholine, adrenaline, serotonin, dopamine and adenosine in brains of homozygous aphakia mice being characterized by mutations affecting the Pitx3 gene. This genetic model exhibits crucial hallmarks of PD on the neuropathological, symptomatic and pharmacological level. Quantitative receptor autoradiography was used to characterize 19 different receptor binding sites in eleven brain regions in order to understand receptor changes on a systemic level. We demonstrated striking differential changes of neurotransmitter receptor densities for numerous receptor types and brain regions, respectively. Most prominent, a strong up-regulation of GABA receptors and associated benzodiazepine binding sites in different brain regions and concomitant down-regulations of striatal nicotinic acetylcholine and serotonergic receptor densities were found. Furthermore, the densities of glutamatergic kainate, muscarinic acetylcholine, adrenergic α1 and dopaminergic D2/D3 receptors were differentially altered. These results present novel insights into the expression of neurotransmitter receptors in Pitx3(ak) mice supporting findings on PD pathology in patients and indicating on the possible underlying mechanisms. The data suggest Pitx3(ak) mice as an appropriate new model to investigate the role of neurotransmitter receptors in PD. Our study highlights the relevance of non-dopaminergic systems in PD and for the understanding of its molecular pathology. PMID:25451278

  17. Computational psychiatry.

    PubMed

    Montague, P Read; Dolan, Raymond J; Friston, Karl J; Dayan, Peter

    2012-01-01

    Computational ideas pervade many areas of science and have an integrative explanatory role in neuroscience and cognitive science. However, computational depictions of cognitive function have had surprisingly little impact on the way we assess mental illness because diseases of the mind have not been systematically conceptualized in computational terms. Here, we outline goals and nascent efforts in the new field of computational psychiatry, which seeks to characterize mental dysfunction in terms of aberrant computations over multiple scales. We highlight early efforts in this area that employ reinforcement learning and game theoretic frameworks to elucidate decision-making in health and disease. Looking forwards, we emphasize a need for theory development and large-scale computational phenotyping in human subjects.

  18. A Fortunate Story of an Unusual AK-47 Bullet Trajectory: Always Keep a Smartphone in Your Pocket.

    PubMed

    Thabouillot, Oscar; Perrier, Pierre; Roche, Nicolas-Charles; Agard, David; Barbier, Olivier; Martin, Guillaume; Viant, Eric; Leclere, Jean-Baptiste

    2016-06-01

    This is a report of a fortunate story of an unusual AK-47 bullet trajectory which took place during the Paris (France) attack of November 13th, 2015. A young man, trying to protect his girlfriend, interfered between her and a shooter. He had been wounded in the posterior compartment of the thigh. The bullet penetrated him and, instead of exiting, rebound against his Smartphone, which was in the front pocket of his pants. Thanks to that, the missile bullet did not injure his girlfriend but ended its trajectory in the fat tissue of his thigh. Thabouillot O , Perrier P , Roche NC , Agard D , Barbier O , Martin G , Viant E , Leclere JB . A fortunate story of an unusual AK-47 bullet trajectory: always keep a Smartphone in your pocket. Prehosp Disaster Med, 2016;31(3):343-345.

  19. Emergent Kondo Lattice Behavior in Iron-Based Superconductors AFe_{2}As_{2} (A=K, Rb, Cs).

    PubMed

    Wu, Y P; Zhao, D; Wang, A F; Wang, N Z; Xiang, Z J; Luo, X G; Wu, T; Chen, X H

    2016-04-01

    Here, we experimentally study the origin of d-electron heavy fermion (HF) behavior in iron-based superconductors (FeSCs) AFe_{2}As_{2} (A=K, Rb, Cs). Nuclear magnetic resonance on ^{75}As reveals a universal coherent-incoherent crossover with a characteristic temperature T^{*}. Below T^{*}, a so-called "Knight shift anomaly" is first observed in FeSCs, which exhibits a scaling behavior similar to f-electron HF materials. Furthermore, the scaling rule also regulates the manifestation of magnetic fluctuation. These results undoubtedly support an emergent Kondo lattice scenario for the d-electron HF behavior, which qualifies the AFe_{2}As_{2} (A=K, Rb, Cs) as d-electron HF superconductors. PMID:27104721

  20. A Fortunate Story of an Unusual AK-47 Bullet Trajectory: Always Keep a Smartphone in Your Pocket.

    PubMed

    Thabouillot, Oscar; Perrier, Pierre; Roche, Nicolas-Charles; Agard, David; Barbier, Olivier; Martin, Guillaume; Viant, Eric; Leclere, Jean-Baptiste

    2016-06-01

    This is a report of a fortunate story of an unusual AK-47 bullet trajectory which took place during the Paris (France) attack of November 13th, 2015. A young man, trying to protect his girlfriend, interfered between her and a shooter. He had been wounded in the posterior compartment of the thigh. The bullet penetrated him and, instead of exiting, rebound against his Smartphone, which was in the front pocket of his pants. Thanks to that, the missile bullet did not injure his girlfriend but ended its trajectory in the fat tissue of his thigh. Thabouillot O , Perrier P , Roche NC , Agard D , Barbier O , Martin G , Viant E , Leclere JB . A fortunate story of an unusual AK-47 bullet trajectory: always keep a Smartphone in your pocket. Prehosp Disaster Med, 2016;31(3):343-345. PMID:27086713

  1. Computed Tomography

    NASA Astrophysics Data System (ADS)

    Castellano, Isabel; Geleijns, Jacob

    After its clinical introduction in 1973, computed tomography developed from an x-ray modality for axial imaging in neuroradiology into a versatile three dimensional imaging modality for a wide range of applications in for example oncology, vascular radiology, cardiology, traumatology and even in interventional radiology. Computed tomography is applied for diagnosis, follow-up studies and screening of healthy subpopulations with specific risk factors. This chapter provides a general introduction in computed tomography, covering a short history of computed tomography, technology, image quality, dosimetry, room shielding, quality control and quality criteria.

  2. Computer Software.

    ERIC Educational Resources Information Center

    Kay, Alan

    1984-01-01

    Discusses the nature and development of computer software. Programing, programing languages, types of software (including dynamic spreadsheets), and software of the future are among the topics considered. (JN)

  3. Performance of the high-resolution atmospheric model HRRR-AK for correcting geodetic observations from spaceborne radars

    PubMed Central

    Gong, W; Meyer, F J; Webley, P; Morton, D

    2013-01-01

    [1] Atmospheric phase delays are considered to be one of the main performance limitations for high-quality satellite radar techniques, especially when applied to ground deformation monitoring. Numerical weather prediction (NWP) models are widely seen as a promising tool for the mitigation of atmospheric delays as they can provide knowledge of the atmospheric conditions at the time of Synthetic Aperture Radar data acquisition. However, a thorough statistical analysis of the performance of using NWP production in radar signal correction is missing to date. This study provides a quantitative analysis of the accuracy in using operational NWP products for signal delay correction in satellite radar geodetic remote sensing. The study focuses on the temperate, subarctic, and Arctic climate regions due to a prevalence of relevant geophysical signals in these areas. In this study, the operational High Resolution Rapid Refresh over the Alaska region (HRRR-AK) model is used and evaluated. Five test sites were selected over Alaska (AK), USA, covering a wide range of climatic regimes that are commonly encountered in high-latitude regions. The performance of the HRRR-AK NWP model for correcting absolute atmospheric range delays of radar signals is assessed by comparing to radiosonde observations. The average estimation accuracy for the one-way zenith total atmospheric delay from 24 h simulations was calculated to be better than ∼14 mm. This suggests that the HRRR-AK operational products are a good data source for spaceborne geodetic radar observations atmospheric delay correction, if the geophysical signal to be observed is larger than 20 mm. PMID:25973360

  4. s-triazine degrading bacterial isolate Arthrobacter sp. AK-YN10, a candidate for bioaugmentation of atrazine contaminated soil.

    PubMed

    Sagarkar, Sneha; Bhardwaj, Pooja; Storck, Veronika; Devers-Lamrani, Marion; Martin-Laurent, Fabrice; Kapley, Atya

    2016-01-01

    The Arthrobacter sp. strain AK-YN10 is an s-triazine pesticide degrading bacterium isolated from a sugarcane field in Central India with history of repeated atrazine use. AK-YN10 was shown to degrade 99 % of atrazine in 30 h from media supplemented with 1000 mg L(-1) of the herbicide. Draft genome sequencing revealed similarity to pAO1, TC1, and TC2 catabolic plasmids of the Arthrobacter taxon. Plasmid profiling analyses revealed the presence of four catabolic plasmids. The trzN, atzB, and atzC atrazine-degrading genes were located on a plasmid of approximately 113 kb.The flagellar operon found in the AK-YN10 draft genome suggests motility, an interesting trait for a bioremediation agent, and was homologous to that of Arthrobacter chlorophenolicus. The multiple s-triazines degradation property of this isolate makes it a good candidate for bioremediation of soils contaminated by s-triazine pesticides. PMID:26403923

  5. s-triazine degrading bacterial isolate Arthrobacter sp. AK-YN10, a candidate for bioaugmentation of atrazine contaminated soil.

    PubMed

    Sagarkar, Sneha; Bhardwaj, Pooja; Storck, Veronika; Devers-Lamrani, Marion; Martin-Laurent, Fabrice; Kapley, Atya

    2016-01-01

    The Arthrobacter sp. strain AK-YN10 is an s-triazine pesticide degrading bacterium isolated from a sugarcane field in Central India with history of repeated atrazine use. AK-YN10 was shown to degrade 99 % of atrazine in 30 h from media supplemented with 1000 mg L(-1) of the herbicide. Draft genome sequencing revealed similarity to pAO1, TC1, and TC2 catabolic plasmids of the Arthrobacter taxon. Plasmid profiling analyses revealed the presence of four catabolic plasmids. The trzN, atzB, and atzC atrazine-degrading genes were located on a plasmid of approximately 113 kb.The flagellar operon found in the AK-YN10 draft genome suggests motility, an interesting trait for a bioremediation agent, and was homologous to that of Arthrobacter chlorophenolicus. The multiple s-triazines degradation property of this isolate makes it a good candidate for bioremediation of soils contaminated by s-triazine pesticides.

  6. A founder EIF2AK4 mutation causes an aggressive form of pulmonary arterial hypertension in Iberian Gypsies.

    PubMed

    Tenorio, J; Navas, P; Barrios, E; Fernández, L; Nevado, J; Quezada, C A; López-Meseguer, M; Arias, P; Mena, R; Lobo, J L; Alvarez, C; Heath, K; Escribano-Subías, P; Lapunzina, P

    2015-12-01

    Pulmonary arterial hypertension (PAH) is a pathological condition characterized by a persistent and progressive elevation of pulmonary vascular resistance with devastating consequences if untreated. In the past recent years, several genes have been related to PAH, however, the molecular defect remains unknown in a significant proportion of patients with familial PAH (∼20%). During the past few years, we have observed that PAH shows a particular behavior in Iberian Gypsies, with more aggressive course and frequently affecting multiple members of the same family. We studied five Gypsy families in whom at least one individual from each family developed a severe form of PAH and in whom no mutation had been identified in the common genes. We applied SNP-array-based homozygosity mapping in three families and obtained, among others, one of which included the gene EIF2AK4, recently reported in patients with PAH from group-1' pulmonary veno-occlusive disease (PVOD) and pulmonary capillary hemangiomatosis (PCH). Subsequently, we sequenced EIF2AK4 and found a homozygous mutation in all five families: c.3344C>T(p.P1115L). The majority of our patients required early lung transplantation. Hence, this mutation appeared with a more severe phenotype than previously reported for other EIF2AK4 mutations. The finding of this novel mutation is important for genetic counseling and calculation of population recurrence risks.

  7. Anchorage, AK

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Anchorage, Alaska and Cook Inlet are seen in this 30 by 30 km (19 by 19 miles) sub-image, acquired May 12, 2000 by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER). Orbiting at an altitude of 705 km (430 miles) on board NASA's Terra satellite, ASTER provides data at a resolution of 15 m (47 feet) and allows creation of this simulated natural color image. At the center of the image is the Ted Stevens Anchorage International Airport; in the upper right corner is Elmendorf Air Force Base. Dark green coniferous forests are seen in the northwest part of the image. A golf course, with its lush green fairways, is just south of the Air Force Base.

    The image covers an area of 30 by 30 km, was acquired May 12, 2000, and is located at 61.2 degrees north latitude and 149.9 degrees west longitude.

    Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) is one of five Earth-observing instruments launched December 18, 1999, on NASA's Terra satellite. The instrument was built by Japan's Ministry of International Trade and Industry. A joint U.S./Japan science team is responsible for validation and calibration of the instrument and the data products. Dr. Anne Kahle at NASA's Jet Propulsion Laboratory, Pasadena, California, is the U.S. science team leader; Moshe Pniel of JPL is the project manager. ASTER is the only high-resolution imaging sensor on Terra. The primary goal of the ASTER mission is to obtain high-resolution image data in 14 channels over the entire land surface, as well as black and white stereo images. With revisit time of between 4 and 16 days, ASTER will provide the capability for repeat coverage of changing areas on Earth's surface.

    The broad spectral coverage and high spectral resolution of ASTER will provide scientists in numerous disciplines with critical information for surface mapping and monitoring dynamic conditions and temporal change. Examples of applications include monitoring glacial advances and retreats, potentially active volcanoes, thermal pollution, and coral reef degradation; identifying crop stress; determining cloud morphology and physical properties; evaluating wetlands; mapping surface temperature of soils and geology; and measuring surface heat balance.

  8. Computer News

    ERIC Educational Resources Information Center

    Science Activities: Classroom Projects and Curriculum Ideas, 2007

    2007-01-01

    This article presents several news stories about computers and technology. (1) Applied Science Associates of Narragansett, Rhode Island is providing computer modeling technology to help locate the remains to the USS Bonhomme Richard, which sank in 1779 after claiming a Revolutionary War victory. (2) Whyville, the leading edu-tainment virtual world…

  9. Cafeteria Computers.

    ERIC Educational Resources Information Center

    Dervarics, Charles

    1992-01-01

    By relying on new computer hardware and software, school food service departments can keep better records of daily food consumption, free and reduced-price meals, inventory, production, and other essentials. The most commonly used systems fall into two basic categories: point-of-sale computers and behind-the-counter systems. State funding efforts…

  10. Computer Recreations.

    ERIC Educational Resources Information Center

    Dewdney, A. K.

    1989-01-01

    Discussed are three examples of computer graphics including biomorphs, Truchet tilings, and fractal popcorn. The graphics are shown and the basic algorithm using multiple iteration of a particular function or mathematical operation is described. An illustration of a snail shell created by computer graphics is presented. (YP)

  11. Computer Insecurity.

    ERIC Educational Resources Information Center

    Wilson, David L.

    1994-01-01

    College administrators recently appealed to students and faculty to change their computer passwords after security experts announced that tens of thousands had been stolen by computer hackers. Federal officials are investigating. Such attacks are not uncommon, but the most effective solutions are either inconvenient or cumbersome. (MSE)

  12. Computer Graphics.

    ERIC Educational Resources Information Center

    Halpern, Jeanne W.

    1970-01-01

    Computer graphics have been called the most exciting development in computer technology. At the University of Michigan, three kinds of graphics output equipment are now being used: symbolic printers, line plotters or drafting devices, and cathode-ray tubes (CRT). Six examples are given that demonstrate the range of graphics use at the University.…

  13. Computing Life

    ERIC Educational Resources Information Center

    National Institute of General Medical Sciences (NIGMS), 2009

    2009-01-01

    Computer advances now let researchers quickly search through DNA sequences to find gene variations that could lead to disease, simulate how flu might spread through one's school, and design three-dimensional animations of molecules that rival any video game. By teaming computers and biology, scientists can answer new and old questions that could…

  14. Grid Computing

    NASA Astrophysics Data System (ADS)

    Foster, Ian

    2001-08-01

    The term "Grid Computing" refers to the use, for computational purposes, of emerging distributed Grid infrastructures: that is, network and middleware services designed to provide on-demand and high-performance access to all important computational resources within an organization or community. Grid computing promises to enable both evolutionary and revolutionary changes in the practice of computational science and engineering based on new application modalities such as high-speed distributed analysis of large datasets, collaborative engineering and visualization, desktop access to computation via "science portals," rapid parameter studies and Monte Carlo simulations that use all available resources within an organization, and online analysis of data from scientific instruments. In this article, I examine the status of Grid computing circa 2000, briefly reviewing some relevant history, outlining major current Grid research and development activities, and pointing out likely directions for future work. I also present a number of case studies, selected to illustrate the potential of Grid computing in various areas of science.

  15. Computational astrophysics

    NASA Technical Reports Server (NTRS)

    Miller, Richard H.

    1987-01-01

    Astronomy is an area of applied physics in which unusually beautiful objects challenge the imagination to explain observed phenomena in terms of known laws of physics. It is a field that has stimulated the development of physical laws and of mathematical and computational methods. Current computational applications are discussed in terms of stellar and galactic evolution, galactic dynamics, and particle motions.

  16. Computational Pathology

    PubMed Central

    Louis, David N.; Feldman, Michael; Carter, Alexis B.; Dighe, Anand S.; Pfeifer, John D.; Bry, Lynn; Almeida, Jonas S.; Saltz, Joel; Braun, Jonathan; Tomaszewski, John E.; Gilbertson, John R.; Sinard, John H.; Gerber, Georg K.; Galli, Stephen J.; Golden, Jeffrey A.; Becich, Michael J.

    2016-01-01

    Context We define the scope and needs within the new discipline of computational pathology, a discipline critical to the future of both the practice of pathology and, more broadly, medical practice in general. Objective To define the scope and needs of computational pathology. Data Sources A meeting was convened in Boston, Massachusetts, in July 2014 prior to the annual Association of Pathology Chairs meeting, and it was attended by a variety of pathologists, including individuals highly invested in pathology informatics as well as chairs of pathology departments. Conclusions The meeting made recommendations to promote computational pathology, including clearly defining the field and articulating its value propositions; asserting that the value propositions for health care systems must include means to incorporate robust computational approaches to implement data-driven methods that aid in guiding individual and population health care; leveraging computational pathology as a center for data interpretation in modern health care systems; stating that realizing the value proposition will require working with institutional administrations, other departments, and pathology colleagues; declaring that a robust pipeline should be fostered that trains and develops future computational pathologists, for those with both pathology and non-pathology backgrounds; and deciding that computational pathology should serve as a hub for data-related research in health care systems. The dissemination of these recommendations to pathology and bioinformatics departments should help facilitate the development of computational pathology. PMID:26098131

  17. I, Computer

    ERIC Educational Resources Information Center

    Barack, Lauren

    2005-01-01

    What child hasn't chatted with friends through a computer? But chatting with a computer? Some Danish scientists have literally put a face on their latest software program, bringing to virtual life storyteller Hans Christian Andersen, who engages users in actual conversations. The digitized Andersen resides at the Hans Christian Andersen Museum in…

  18. Diagnosis of High Bifurcation of the Abdominal Aorta with Associated Vascular Variations: Case Report with Multidedector Computed Tomography

    PubMed Central

    Atalar, Mehmet Haydar; Salk, Ismail; Bozbiyik, Nisa; Cetin, Ali

    2015-01-01

    Summary Background Variations of the branches and bifurcation of the abdominal aorta and their relations with other abdominal structures and organs are important concerning abdominal and spinal surgery. Case Report In this report, authors present a high -positioned bifurcation of the abdominal aorta at the level of the L3 vertebral body and its associations with multiple variations of other abdominal arteries during contrast-enhanced multi-detector computed tomography (MDCT) examination of the abdomen. Conclusions We reported on a unique clinically and surgically significant case of variations of the abdominal aorta as related to the location and type of bifurcation. The awareness of the variations of the abdominal aorta is of great importance for surgeons in order to reduce complications during abdominal and spinal interventions, as well as for radiologists for precise interpretation of angiograms. PMID:26688701

  19. [Simulation of thoracoscopic esophagectomy by three-dimensional computed tomography].

    PubMed

    Ichikawa, Hirofumi

    2007-07-01

    The virtual operative field of thoracoscopic surgery for esophageal cancer was created by three-dimensional (3D) computed tomography (CT) imaging. Major vessels, bone, trachea, bronchi, lung, esophagus, lymph nodes and broncial arteries were constructed by a Zio M900 workstation from multidetector-row CT scanning data. The mediastinal lymph nodes and bilateral bronchial arteries were drawn by a free-hand tool. The static images and fry-through movies by a virtual endoscopy mode were useful for simulation of the endoscopic surgery, which is usually performed in very limited viewing. The location of lymph nodes and bronchial arteries in relation to the adjacent anatomical structures was realized by this virtual vision. The bronchial arteries should be preserved to avoid tracheobronchial ischemia, especially in case of salvage surgery after definitive chemoradiotherapy. The left bronchial arteries had many anatomical variations, so that 3D CT images were helpful to identify and to preserve the left bronchial arteries. In conclusion, the simulation of thoracoscopic esophagectomy by 3D CT is thought to contribute to safty and precise navigation for this kind of surgery. PMID:17763681

  20. [Contribution of X-ray computed tomography in the evaluation of kidney performance].

    PubMed

    Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent

    2012-07-01

    X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. PMID:22019734

  1. Personal Computers.

    ERIC Educational Resources Information Center

    Toong, Hoo-min D.; Gupta, Amar

    1982-01-01

    Describes the hardware, software, applications, and current proliferation of personal computers (microcomputers). Includes discussions of microprocessors, memory, output (including printers), application programs, the microcomputer industry, and major microcomputer manufacturers (Apple, Radio Shack, Commodore, and IBM). (JN)

  2. Sort computation

    NASA Technical Reports Server (NTRS)

    Dorband, John E.

    1988-01-01

    Sorting has long been used to organize data in preparation for further computation, but sort computation allows some types of computation to be performed during the sort. Sort aggregation and sort distribution are the two basic forms of sort computation. Sort aggregation generates an accumulative or aggregate result for each group of records and places this result in one of the records. An aggregate operation can be any operation that is both associative and commutative, i.e., any operation whose result does not depend on the order of the operands or the order in which the operations are performed. Sort distribution copies the value from a field of a specific record in a group into that field in every record of that group.

  3. LHC Computing

    SciTech Connect

    Lincoln, Don

    2015-07-28

    The LHC is the world’s highest energy particle accelerator and scientists use it to record an unprecedented amount of data. This data is recorded in electronic format and it requires an enormous computational infrastructure to convert the raw data into conclusions about the fundamental rules that govern matter. In this video, Fermilab’s Dr. Don Lincoln gives us a sense of just how much data is involved and the incredible computer resources that makes it all possible.

  4. Advanced computing

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Advanced concepts in hardware, software and algorithms are being pursued for application in next generation space computers and for ground based analysis of space data. The research program focuses on massively parallel computation and neural networks, as well as optical processing and optical networking which are discussed under photonics. Also included are theoretical programs in neural and nonlinear science, and device development for magnetic and ferroelectric memories.

  5. Computational chemistry

    NASA Technical Reports Server (NTRS)

    Arnold, J. O.

    1987-01-01

    With the advent of supercomputers, modern computational chemistry algorithms and codes, a powerful tool was created to help fill NASA's continuing need for information on the properties of matter in hostile or unusual environments. Computational resources provided under the National Aerodynamics Simulator (NAS) program were a cornerstone for recent advancements in this field. Properties of gases, materials, and their interactions can be determined from solutions of the governing equations. In the case of gases, for example, radiative transition probabilites per particle, bond-dissociation energies, and rates of simple chemical reactions can be determined computationally as reliably as from experiment. The data are proving to be quite valuable in providing inputs to real-gas flow simulation codes used to compute aerothermodynamic loads on NASA's aeroassist orbital transfer vehicles and a host of problems related to the National Aerospace Plane Program. Although more approximate, similar solutions can be obtained for ensembles of atoms simulating small particles of materials with and without the presence of gases. Computational chemistry has application in studying catalysis, properties of polymers, all of interest to various NASA missions, including those previously mentioned. In addition to discussing these applications of computational chemistry within NASA, the governing equations and the need for supercomputers for their solution is outlined.

  6. Chromatin Computation

    PubMed Central

    Bryant, Barbara

    2012-01-01

    In living cells, DNA is packaged along with protein and RNA into chromatin. Chemical modifications to nucleotides and histone proteins are added, removed and recognized by multi-functional molecular complexes. Here I define a new computational model, in which chromatin modifications are information units that can be written onto a one-dimensional string of nucleosomes, analogous to the symbols written onto cells of a Turing machine tape, and chromatin-modifying complexes are modeled as read-write rules that operate on a finite set of adjacent nucleosomes. I illustrate the use of this “chromatin computer” to solve an instance of the Hamiltonian path problem. I prove that chromatin computers are computationally universal – and therefore more powerful than the logic circuits often used to model transcription factor control of gene expression. Features of biological chromatin provide a rich instruction set for efficient computation of nontrivial algorithms in biological time scales. Modeling chromatin as a computer shifts how we think about chromatin function, suggests new approaches to medical intervention, and lays the groundwork for the engineering of a new class of biological computing machines. PMID:22567109

  7. Computational structures for robotic computations

    NASA Technical Reports Server (NTRS)

    Lee, C. S. G.; Chang, P. R.

    1987-01-01

    The computational problem of inverse kinematics and inverse dynamics of robot manipulators by taking advantage of parallelism and pipelining architectures is discussed. For the computation of inverse kinematic position solution, a maximum pipelined CORDIC architecture has been designed based on a functional decomposition of the closed-form joint equations. For the inverse dynamics computation, an efficient p-fold parallel algorithm to overcome the recurrence problem of the Newton-Euler equations of motion to achieve the time lower bound of O(log sub 2 n) has also been developed.

  8. [DNA computing].

    PubMed

    Błasiak, Janusz; Krasiński, Tadeusz; Popławski, Tomasz; Sakowski, Sebastian

    2011-01-01

    Biocomputers can be an alternative for traditional "silicon-based" computers, which continuous development may be limited due to further miniaturization (imposed by the Heisenberg Uncertainty Principle) and increasing the amount of information between the central processing unit and the main memory (von Neuman bottleneck). The idea of DNA computing came true for the first time in 1994, when Adleman solved the Hamiltonian Path Problem using short DNA oligomers and DNA ligase. In the early 2000s a series of biocomputer models was presented with a seminal work of Shapiro and his colleguas who presented molecular 2 state finite automaton, in which the restriction enzyme, FokI, constituted hardware and short DNA oligomers were software as well as input/output signals. DNA molecules provided also energy for this machine. DNA computing can be exploited in many applications, from study on the gene expression pattern to diagnosis and therapy of cancer. The idea of DNA computing is still in progress in research both in vitro and in vivo and at least promising results of these research allow to have a hope for a breakthrough in the computer science. PMID:21735816

  9. Computational mechanics

    SciTech Connect

    Goudreau, G.L.

    1993-03-01

    The Computational Mechanics thrust area sponsors research into the underlying solid, structural and fluid mechanics and heat transfer necessary for the development of state-of-the-art general purpose computational software. The scale of computational capability spans office workstations, departmental computer servers, and Cray-class supercomputers. The DYNA, NIKE, and TOPAZ codes have achieved world fame through our broad collaborators program, in addition to their strong support of on-going Lawrence Livermore National Laboratory (LLNL) programs. Several technology transfer initiatives have been based on these established codes, teaming LLNL analysts and researchers with counterparts in industry, extending code capability to specific industrial interests of casting, metalforming, and automobile crash dynamics. The next-generation solid/structural mechanics code, ParaDyn, is targeted toward massively parallel computers, which will extend performance from gigaflop to teraflop power. Our work for FY-92 is described in the following eight articles: (1) Solution Strategies: New Approaches for Strongly Nonlinear Quasistatic Problems Using DYNA3D; (2) Enhanced Enforcement of Mechanical Contact: The Method of Augmented Lagrangians; (3) ParaDyn: New Generation Solid/Structural Mechanics Codes for Massively Parallel Processors; (4) Composite Damage Modeling; (5) HYDRA: A Parallel/Vector Flow Solver for Three-Dimensional, Transient, Incompressible Viscous How; (6) Development and Testing of the TRIM3D Radiation Heat Transfer Code; (7) A Methodology for Calculating the Seismic Response of Critical Structures; and (8) Reinforced Concrete Damage Modeling.

  10. Protoplanetary Disk Shadowing by Gas Infalling onto the Young Star AK Sco

    NASA Astrophysics Data System (ADS)

    Gómez de Castro, Ana I.; Loyd, Robert O. P.; France, Kevin; Sytov, Alexey; Bisikalo, Dmitry

    2016-02-01

    Young solar-type stars grow through the accretion of material from the circumstellar disk during pre-main-sequence (PMS) evolution. The ultraviolet radiation generated in this process plays a key role in the chemistry and evolution of young planetary disks. In particular, the hydrogen Lyα line (Lyα) etches the disk surface by driving photoevaporative flows that control disk evolution. Using the Hubble Space Telescope, we have monitored the PMS binary star AK Sco during the periastron passage and have detected a drop of the H2 flux by up to 10% lasting 5.9 hr. We show that the decrease of the H2 flux can be produced by the occultation of the stellar Lyα photons by a gas stream in free fall from 3 R{}*. Given the high optical depth of the Lyα line, a very low gas column of {N}{{H}}\\gt 5× {10}17 cm‑2 suffices to block the Lyα radiation without producing noticeable effects in the rest of the stellar spectral tracers.

  11. Protoplanetary Disk Shadowing by Gas Infalling onto the Young Star AK Sco

    NASA Astrophysics Data System (ADS)

    Gómez de Castro, Ana I.; Loyd, Robert O. P.; France, Kevin; Sytov, Alexey; Bisikalo, Dmitry

    2016-02-01

    Young solar-type stars grow through the accretion of material from the circumstellar disk during pre-main-sequence (PMS) evolution. The ultraviolet radiation generated in this process plays a key role in the chemistry and evolution of young planetary disks. In particular, the hydrogen Lyα line (Lyα) etches the disk surface by driving photoevaporative flows that control disk evolution. Using the Hubble Space Telescope, we have monitored the PMS binary star AK Sco during the periastron passage and have detected a drop of the H2 flux by up to 10% lasting 5.9 hr. We show that the decrease of the H2 flux can be produced by the occultation of the stellar Lyα photons by a gas stream in free fall from 3 R{}*. Given the high optical depth of the Lyα line, a very low gas column of {N}{{H}}\\gt 5× {10}17 cm-2 suffices to block the Lyα radiation without producing noticeable effects in the rest of the stellar spectral tracers.

  12. Evidence of accretion triggered oscillations in the pre-main-sequence interacting binary AK Sco

    NASA Astrophysics Data System (ADS)

    Gómez, de Castro, Ana I.; López-Santiago, Javier; Talavera, Antonio

    2013-02-01

    Pre-main sequence (PMS) binaries are surrounded by circumbinary discs from which matter falls on to both components. The material dragged from the circumbinary disc flows on to each star through independent streams channelled by the variable gravitational field. The action of the bar-like potential is most prominent in high eccentricity systems made of two equal mass stars. AK Sco is a unique PMS system composed of two F5 stars in an orbit with e = 0.47. Henceforth, it is an ideal laboratory to study matter infall in binaries and its role in orbit circularization. In this Letter, we report the detection of a 1.3 mHz ultra low-frequency oscillation in the ultraviolet light curve at periastron passage. This oscillation lasts 7 ks being most likely fed by the gravitational energy released when the stream's tails spiralling on to each star get in contact at periastron passage enhancing the accretion flow; this unveils a new mechanism for angular momentum loss during PMS evolution and a new type of interacting binary.

  13. DETECTION OF SHARP SYMMETRIC FEATURES IN THE CIRCUMBINARY DISK AROUND AK Sco

    SciTech Connect

    Janson, Markus; Asensio-Torres, Ruben; Thalmann, Christian; Meyer, Michael R.; Garufi, Antonio; Boccaletti, Anthony; Maire, Anne-Lise; Henning, Thomas; Pohl, Adriana; Zurlo, Alice; Marzari, Francesco; Carson, Joseph C.; Augereau, Jean-Charles; Desidera, Silvano

    2016-01-01

    The Search for Planets Orbiting Two Stars survey aims to study the formation and distribution of planets in binary systems by detecting and characterizing circumbinary planets and their formation environments through direct imaging. With the SPHERE Extreme Adaptive Optics instrument, a good contrast can be achieved even at small (<300 mas) separations from bright stars, which enables studies of planets and disks in a separation range that was previously inaccessible. Here, we report the discovery of resolved scattered light emission from the circumbinary disk around the well-studied young double star AK Sco, at projected separations in the ∼13–40 AU range. The sharp morphology of the imaged feature is surprising, given the smooth appearance of the disk in its spectral energy distribution. We show that the observed morphology can be represented either as a highly eccentric ring around AK Sco, or as two separate spiral arms in the disk, wound in opposite directions. The relative merits of these interpretations are discussed, as well as whether these features may have been caused by one or several circumbinary planets interacting with the disk.

  14. Computational Psychiatry

    PubMed Central

    Wang, Xiao-Jing; Krystal, John H.

    2014-01-01

    Psychiatric disorders such as autism and schizophrenia arise from abnormalities in brain systems that underlie cognitive, emotional and social functions. The brain is enormously complex and its abundant feedback loops on multiple scales preclude intuitive explication of circuit functions. In close interplay with experiments, theory and computational modeling are essential for understanding how, precisely, neural circuits generate flexible behaviors and their impairments give rise to psychiatric symptoms. This Perspective highlights recent progress in applying computational neuroscience to the study of mental disorders. We outline basic approaches, including identification of core deficits that cut across disease categories, biologically-realistic modeling bridging cellular and synaptic mechanisms with behavior, model-aided diagnosis. The need for new research strategies in psychiatry is urgent. Computational psychiatry potentially provides powerful tools for elucidating pathophysiology that may inform both diagnosis and treatment. To achieve this promise will require investment in cross-disciplinary training and research in this nascent field. PMID:25442941

  15. Computational mechanics

    SciTech Connect

    Raboin, P J

    1998-01-01

    The Computational Mechanics thrust area is a vital and growing facet of the Mechanical Engineering Department at Lawrence Livermore National Laboratory (LLNL). This work supports the development of computational analysis tools in the areas of structural mechanics and heat transfer. Over 75 analysts depend on thrust area-supported software running on a variety of computing platforms to meet the demands of LLNL programs. Interactions with the Department of Defense (DOD) High Performance Computing and Modernization Program and the Defense Special Weapons Agency are of special importance as they support our ParaDyn project in its development of new parallel capabilities for DYNA3D. Working with DOD customers has been invaluable to driving this technology in directions mutually beneficial to the Department of Energy. Other projects associated with the Computational Mechanics thrust area include work with the Partnership for a New Generation Vehicle (PNGV) for ''Springback Predictability'' and with the Federal Aviation Administration (FAA) for the ''Development of Methodologies for Evaluating Containment and Mitigation of Uncontained Engine Debris.'' In this report for FY-97, there are five articles detailing three code development activities and two projects that synthesized new code capabilities with new analytic research in damage/failure and biomechanics. The article this year are: (1) Energy- and Momentum-Conserving Rigid-Body Contact for NIKE3D and DYNA3D; (2) Computational Modeling of Prosthetics: A New Approach to Implant Design; (3) Characterization of Laser-Induced Mechanical Failure Damage of Optical Components; (4) Parallel Algorithm Research for Solid Mechanics Applications Using Finite Element Analysis; and (5) An Accurate One-Step Elasto-Plasticity Algorithm for Shell Elements in DYNA3D.

  16. Long noncoding RNA AK126698 inhibits proliferation and migration of non-small cell lung cancer cells by targeting Frizzled-8 and suppressing Wnt/β-catenin signaling pathway

    PubMed Central

    Fu, Xiao; Li, Hui; Liu, Chunxiao; Hu, Bin; Li, Tong; Wang, Yang

    2016-01-01

    Background Recent studies indicate that long noncoding RNAs (lncRNAs) play a key role in the control of cellular processes such as proliferation, metastasis, and differentiation. The lncRNA dysregulation has been identified in all types of cancer. We previously found that lncRNA AK126698 suppresses cisplatin resistance in A549 cells through the Wnt/β-catenin signaling pathway. However, the clinical significance of lncRNA AK126698 and the molecular mechanisms through which it regulates cancer cell proliferation and migration are largely unknown. Methods We examined the expression of lncRNA AK126698 in 56 non-small cell lung cancer (NSCLC) tissue samples and three NSCLC cell lines using quantitative real-time polymerase chain reaction. Gain and loss of function approaches were used to evaluate the biological function of AK126698 in NSCLC cells. The effects of lncRNA AK126698 on cell proliferation were investigated using cell counting kit-8 and 5-ethynyl-2′-deoxyuridine assays, and apoptosis was measured by flow cytometry. Protein levels of AK126698 targets were evaluated by Western blotting. Results Our results showed that lncRNA AK126698 was significantly downregulated in NSCLC tissues, compared with paired adjacent nontumor tissue samples. Furthermore, lower AK126698 expression was associated with larger tumor size and advanced tumor stage. Ectopic AK126698 expression inhibited cell proliferation and migration and induced apoptosis. Conversely, decreased AK126698 expression promoted cell proliferation and migration and inhibited cell apoptosis. Importantly, we demonstrated that Frizzled-8, a receptor of Wnt/β-catenin pathway, was a target of AK126698. Furthermore, AK126698 could inhibit the activation of Wnt/β-catenin pathway, which was demonstrated by measuring the expression levels of Axin1, β-catenin, c-myc, cyclin D1, and E-cadherin. Conclusion It was found in the study that lncRNA AK126698 inhibits the proliferation and migration of NSCLC cells by

  17. Computer viruses

    NASA Technical Reports Server (NTRS)

    Denning, Peter J.

    1988-01-01

    The worm, Trojan horse, bacterium, and virus are destructive programs that attack information stored in a computer's memory. Virus programs, which propagate by incorporating copies of themselves into other programs, are a growing menace in the late-1980s world of unprotected, networked workstations and personal computers. Limited immunity is offered by memory protection hardware, digitally authenticated object programs,and antibody programs that kill specific viruses. Additional immunity can be gained from the practice of digital hygiene, primarily the refusal to use software from untrusted sources. Full immunity requires attention in a social dimension, the accountability of programmers.

  18. LHC Computing

    ScienceCinema

    Lincoln, Don

    2016-07-12

    The LHC is the world’s highest energy particle accelerator and scientists use it to record an unprecedented amount of data. This data is recorded in electronic format and it requires an enormous computational infrastructure to convert the raw data into conclusions about the fundamental rules that govern matter. In this video, Fermilab’s Dr. Don Lincoln gives us a sense of just how much data is involved and the incredible computer resources that makes it all possible.

  19. Computational vision

    NASA Technical Reports Server (NTRS)

    Barrow, H. G.; Tenenbaum, J. M.

    1981-01-01

    The range of fundamental computational principles underlying human vision that equally apply to artificial and natural systems is surveyed. There emerges from research a view of the structuring of vision systems as a sequence of levels of representation, with the initial levels being primarily iconic (edges, regions, gradients) and the highest symbolic (surfaces, objects, scenes). Intermediate levels are constrained by information made available by preceding levels and information required by subsequent levels. In particular, it appears that physical and three-dimensional surface characteristics provide a critical transition from iconic to symbolic representations. A plausible vision system design incorporating these principles is outlined, and its key computational processes are elaborated.

  20. Computer systems

    NASA Technical Reports Server (NTRS)

    Olsen, Lola

    1992-01-01

    In addition to the discussions, Ocean Climate Data Workshop hosts gave participants an opportunity to hear about, see, and test for themselves some of the latest computer tools now available for those studying climate change and the oceans. Six speakers described computer systems and their functions. The introductory talks were followed by demonstrations to small groups of participants and some opportunities for participants to get hands-on experience. After this familiarization period, attendees were invited to return during the course of the Workshop and have one-on-one discussions and further hands-on experience with these systems. Brief summaries or abstracts of introductory presentations are addressed.

  1. Computer Routing.

    ERIC Educational Resources Information Center

    Malone, Roger

    1991-01-01

    Computerized bus-routing systems plot the most efficient routes, cut the time it takes to draw routes, and generate reports quickly and accurately. However, school districts often underestimate the amount of work necessary to get information into the computer database. (MLF)

  2. Computer Corner.

    ERIC Educational Resources Information Center

    Mason, Margie

    1985-01-01

    This article: describes how to prevent pins on game paddles from breaking; suggests using needlepoint books for ideas to design computer graphics; lists a BASIC program to create a Christmas tree, with extension activities; suggests a LOGO Christmas activity; and describes a book on the development of microcomputers. (JN)

  3. Business Computers.

    ERIC Educational Resources Information Center

    Canipe, Stephen L.

    A brief definition of some fundamentals of microcomputers and of the ways they may be used in small businesses can help potential buyers make informed purchases. Hardware (the mechanical devices from which computers are made) described here are the video display, keyboard, central processing unit, "random access" and "read only" memories, cassette…

  4. Computational trigonometry

    SciTech Connect

    Gustafson, K.

    1994-12-31

    By means of the author`s earlier theory of antieigenvalues and antieigenvectors, a new computational approach to iterative methods is presented. This enables an explicit trigonometric understanding of iterative convergence and provides new insights into the sharpness of error bounds. Direct applications to Gradient descent, Conjugate gradient, GCR(k), Orthomin, CGN, GMRES, CGS, and other matrix iterative schemes will be given.

  5. Computational Physics.

    ERIC Educational Resources Information Center

    Borcherds, P. H.

    1986-01-01

    Describes an optional course in "computational physics" offered at the University of Birmingham. Includes an introduction to numerical methods and presents exercises involving fast-Fourier transforms, non-linear least-squares, Monte Carlo methods, and the three-body problem. Recommends adding laboratory work into the course in the future. (TW)

  6. Computer Recreations.

    ERIC Educational Resources Information Center

    Dewdney, A. K.

    1988-01-01

    Describes the creation of the computer program "BOUNCE," designed to simulate a weighted piston coming into equilibrium with a cloud of bouncing balls. The model follows the ideal gas law. Utilizes the critical event technique to create the model. Discusses another program, "BOOM," which simulates a chain reaction. (CW)

  7. Networking computers.

    PubMed

    McBride, D C

    1997-03-01

    This decade the role of the personal computer has shifted dramatically from a desktop device designed to increase individual productivity and efficiency to an instrument of communication linking people and machines in different places with one another. A computer in one city can communicate with another that may be thousands of miles away. Networking is how this is accomplished. Just like the voice network used by the telephone, computer networks transmit data and other information via modems over these same telephone lines. A network can be created over both short and long distances. Networks can be established within a hospital or medical building or over many hospitals or buildings covering many geographic areas. Those confined to one location are called LANs, local area networks. Those that link computers in one building to those at other locations are known as WANs, or wide area networks. The ultimate wide area network is the one we've all been hearing so much about these days--the Internet, and its World Wide Web. Setting up a network is a process that requires careful planning and commitment. To avoid potential pitfalls and to make certain the network you establish meets your needs today and several years down the road, several steps need to be followed. This article reviews the initial steps involved in getting ready to network.

  8. Computational Estimation

    ERIC Educational Resources Information Center

    Fung, Maria G.; Latulippe, Christine L.

    2010-01-01

    Elementary school teachers are responsible for constructing the foundation of number sense in youngsters, and so it is recommended that teacher-training programs include an emphasis on number sense to ensure the development of dynamic, productive computation and estimation skills in students. To better prepare preservice elementary school teachers…

  9. Computational Musicology.

    ERIC Educational Resources Information Center

    Bel, Bernard; Vecchione, Bernard

    1993-01-01

    Asserts that a revolution has been occurring in musicology since the 1970s. Contends that music has change from being only a source of emotion to appearing more open to science and techniques based on computer technology. Describes recent research and other writings about the topic and provides an extensive bibliography. (CFR)

  10. Strain-Driven Approach to Quantum Criticality in AFe_{2}As_{2} with A=K, Rb, and Cs.

    PubMed

    Eilers, Felix; Grube, Kai; Zocco, Diego A; Wolf, Thomas; Merz, Michael; Schweiss, Peter; Heid, Rolf; Eder, Robert; Yu, Rong; Zhu, Jian-Xin; Si, Qimiao; Shibauchi, Takasada; Löhneysen, Hilbert V

    2016-06-10

    The iron-based superconductors AFe_{2}As_{2} with A=K, Rb, Cs exhibit large Sommerfeld coefficients approaching those of heavy-fermion systems. We have investigated the magnetostriction and thermal expansion of this series to shed light on this unusual behavior. Quantum oscillations of the magnetostriction allow identifying the band-specific quasiparticle masses which by far exceed the band-structure derived masses. The divergence of the Grüneisen ratio derived from thermal expansion indicates that with increasing volume along the series a quantum critical point is approached. The critical fluctuations responsible for the enhancement of the quasiparticle masses appear to weaken the superconducting state. PMID:27341252

  11. Amorphous Computing

    NASA Astrophysics Data System (ADS)

    Sussman, Gerald

    2002-03-01

    Digital computers have always been constructed to behave as precise arrangements of reliable parts, and our techniques for organizing computations depend upon this precision and reliability. Two emerging technologies, however, are begnning to undercut these assumptions about constructing and programming computers. These technologies -- microfabrication and bioengineering -- will make it possible to assemble systems composed of myriad information- processing units at almost no cost, provided: 1) that not all the units need to work correctly; and 2) that there is no need to manufacture precise geometrical arrangements or interconnection patterns among them. Microelectronic mechanical components are becoming so inexpensive to manufacture that we can anticipate combining logic circuits, microsensors, actuators, and communications devices integrated on the same chip to produce particles that could be mixed with bulk materials, such as paints, gels, and concrete. Imagine coating bridges or buildings with smart paint that can sense and report on traffic and wind loads and monitor structural integrity of the bridge. A smart paint coating on a wall could sense vibrations, monitor the premises for intruders, or cancel noise. Even more striking, there has been such astounding progress in understanding the biochemical mechanisms in individual cells, that it appears we'll be able to harness these mechanisms to construct digital- logic circuits. Imagine a discipline of cellular engineering that could tailor-make biological cells that function as sensors and actuators, as programmable delivery vehicles for pharmaceuticals, as chemical factories for the assembly of nanoscale structures. Fabricating such systems seem to be within our reach, even if it is not yet within our grasp Fabrication, however, is only part of the story. We can envision producing vast quantities of individual computing elements, whether microfabricated particles, engineered cells, or macromolecular computing

  12. Bacteria as computers making computers

    PubMed Central

    Danchin, Antoine

    2009-01-01

    Various efforts to integrate biological knowledge into networks of interactions have produced a lively microbial systems biology. Putting molecular biology and computer sciences in perspective, we review another trend in systems biology, in which recursivity and information replace the usual concepts of differential equations, feedback and feedforward loops and the like. Noting that the processes of gene expression separate the genome from the cell machinery, we analyse the role of the separation between machine and program in computers. However, computers do not make computers. For cells to make cells requires a specific organization of the genetic program, which we investigate using available knowledge. Microbial genomes are organized into a paleome (the name emphasizes the role of the corresponding functions from the time of the origin of life), comprising a constructor and a replicator, and a cenome (emphasizing community-relevant genes), made up of genes that permit life in a particular context. The cell duplication process supposes rejuvenation of the machine and replication of the program. The paleome also possesses genes that enable information to accumulate in a ratchet-like process down the generations. The systems biology must include the dynamics of information creation in its future developments. PMID:19016882

  13. RATIO COMPUTER

    DOEpatents

    Post, R.F.

    1958-11-11

    An electronic computer circuit is described for producing an output voltage proportional to the product or quotient of tbe voltages of a pair of input signals. ln essence, the disclosed invention provides a computer having two channels adapted to receive separate input signals and each having amplifiers with like fixed amplification factors and like negatlve feedback amplifiers. One of the channels receives a constant signal for comparison purposes, whereby a difference signal is produced to control the amplification factors of the variable feedback amplifiers. The output of the other channel is thereby proportional to the product or quotient of input signals depending upon the relation of input to fixed signals in the first mentioned channel.

  14. Computational Combustion

    SciTech Connect

    Westbrook, C K; Mizobuchi, Y; Poinsot, T J; Smith, P J; Warnatz, J

    2004-08-26

    Progress in the field of computational combustion over the past 50 years is reviewed. Particular attention is given to those classes of models that are common to most system modeling efforts, including fluid dynamics, chemical kinetics, liquid sprays, and turbulent flame models. The developments in combustion modeling are placed into the time-dependent context of the accompanying exponential growth in computer capabilities and Moore's Law. Superimposed on this steady growth, the occasional sudden advances in modeling capabilities are identified and their impacts are discussed. Integration of submodels into system models for spark ignition, diesel and homogeneous charge, compression ignition engines, surface and catalytic combustion, pulse combustion, and detonations are described. Finally, the current state of combustion modeling is illustrated by descriptions of a very large jet lifted 3D turbulent hydrogen flame with direct numerical simulation and 3D large eddy simulations of practical gas burner combustion devices.

  15. Assessment of liver ablation using cone beam computed tomography

    PubMed Central

    Abdel-Rehim, Mohamed; Ronot, Maxime; Sibert, Annie; Vilgrain, Valérie

    2015-01-01

    AIM: To investigate the feasibility and accuracy of cone beam computed tomography (CBCT) in assessing the ablation zone after liver tumor ablation. METHODS: Twenty-three patients (17 men and 6 women, range: 45-85 years old, mean age 65 years) with malignant liver tumors underwent ultrasound-guided percutaneous tumor ablation [radiofrequency (n = 14), microwave (n = 9)] followed by intravenous contrast-enhanced CBCT. Baseline multidetector computed tomography (MDCT) and peri-procedural CBCT images were compared. CBCT image quality was assessed as poor, good, or excellent. Image fusion was performed to assess tumor coverage, and quality of fusion was rated as bad, good, or excellent. Ablation zone volumes on peri-procedural CBCT and post-procedural MDCT were compared using the non-parametric paired Wilcoxon t-test. RESULTS: Rate of primary ablation effectiveness was 100%. There were no complications related to ablation. Local tumor recurrence and new liver tumors were found 3 mo after initial treatment in one patient (4%). The ablation zone was identified in 21/23 (91.3%) patients on CBCT. The fusion of baseline MDCT and peri-procedural CBCT images was feasible in all patients and showed satisfactory tumor coverage (at least 5-mm margin). CBCT image quality was poor, good, and excellent in 2 (9%), 8 (35%), and 13 (56%), patients respectively. Registration quality between peri-procedural CBCT and post-procedural MDCT images was good to excellent in 17/23 (74%) patients. The median ablation volume on peri-procedural CBCT and post-procedural MDCT was 30 cm3 (range: 4-95 cm3) and 30 cm3 (range: 4-124 cm3), respectively (P-value > 0.2). There was a good correlation (r = 0.79) between the volumes of the two techniques. CONCLUSION: Contrast-enhanced CBCT after tumor ablation of the liver allows early assessment of the ablation zone. PMID:25593467

  16. Barrow Ak: A Focal Point for Ice-Albedo-Transmission Feedback Processes in Arctic Sea Ice.

    NASA Astrophysics Data System (ADS)

    Grenfell, T. C.; Perovich, D. K.; Eicken, H.

    2003-12-01

    represents a serious oversimplification that will significantly limit the predictive power of regional and large scale climate and dynamics models. An approach to dealing with this problem is to carry out surface-based observations of the processes involved to determine the detailed spatial and temporal variability associated with the various surface types and develop appropriate models to apply this information on larger scales. We argue that Barrow AK is critically situated for studies of the processes described above. We will present supporting results from a three-year observational sequence of heat and mass balance of the ice cover in conjunction with the interaction of solar radiation with the ice and adjacent tundra and lakes. This information allows us to make an accurate determination of partitioning of solar heating in this zone and provides the basis for IAT feedback modeling. We will also describe some modifications that will be important for generalizing to conditions attendant to increases in the length of the melt season. We propose that this type of study be continued during IPY 2007/08 and that Barrow Ak is an area of critical importance. It offers a key scientific location in combination with superior logistics support and extensive opportunities for K-12 outreach and support of higher education.

  17. Computer Game

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Using NASA studies of advanced lunar exploration and colonization, KDT Industries, Inc. and Wesson International have developed MOONBASE, a computer game. The player, or team commander, must build and operate a lunar base using NASA technology. He has 10 years to explore the surface, select a site and assemble structures brought from Earth into an efficient base. The game was introduced in 1991 by Texas Space Grant Consortium.

  18. Computer centers

    NASA Astrophysics Data System (ADS)

    The National Science Foundation has renewed grants to four of its five supercomputer centers. Average annual funding will rise from $10 million to $14 million so facilities can be upgraded and training and education expanded. As cooperative projects, the centers also receive money from states, universities, computer vendors and industry. The centers support research in fluid dynamics, atmospheric modeling, engineering geophysics and many other scientific disciplines.

  19. Singularity computations

    NASA Technical Reports Server (NTRS)

    Swedlow, J. L.

    1976-01-01

    An approach is described for singularity computations based on a numerical method for elastoplastic flow to delineate radial and angular distribution of field quantities and measure the intensity of the singularity. The method is applicable to problems in solid mechanics and lends itself to certain types of heat flow and fluid motion studies. Its use is not limited to linear, elastic, small strain, or two-dimensional situations.

  20. The Entamoeba histolytica, Arp2/3 Complex Is Recruited to Phagocytic Cups through an Atypical Kinase EhAK1

    PubMed Central

    Babuta, Mrigya; Mansuri, M Shahid; Bhattacharya, Sudha; Bhattacharya, Alok

    2015-01-01

    The parasite Entamoeba histolytica is the etiological agent of amoebiasis and phagocytosis plays a key role in virulence of this organism. Signaling pathways involved in activation of cytoskeletal dynamics required for phagocytosis remain to be elucidated. Phagocytosis is initiated with sequential recruitment of EhC2PK, EhCaBP1, EhCaBP3 and an atypical kinase EhAK1 after particle attachment. Here we show that EhARPC1, an essential subunit of the actin branching complex Arp 2/3 is recruited to the phagocytic initiation sites by EhAK1. Imaging, expression knockdown of different molecules and pull down experiments suggest that EhARPC1 interacts with EhAK1 and that it is required during initiation of phagocytosis and phagosome formation. Moreover, recruitment of EhARPC2 at the phagocytosis initiation by EhAK1 is also observed, indicating that the Arp 2/3 complex is recruited. In conclusion, these results suggests a novel mechanism of recruitment of Arp 2/3 complex during phagocytosis in E. histolytica. PMID:26646565

  1. Availability of ground water on Federal land near the Ak-Chin Indian Reservation, Arizona: a reconnaissance study

    USGS Publications Warehouse

    Wilson, Richard P.

    1979-01-01

    Sufficient ground water to provide about 2.1 million acre-feet in a 25-year period is available for delivery to the Ak-Chin Indian Reservation from Federal land in the Vekol Valley, Waterman Wash area, and Bosque area in south-central Arizona. Withdrawal of 85,000 acre-feet per year as required by the Ak-Chin water-supply act--Public Law 95-328--will greatly deplete the amount of water in storage and may cause land subsidence in the areas. Study concurrent with well-field development will enable design changes to minimize pumping costs , water-level declines, movement of poor-quality water into the well fields, and potential land subsidence and associated earth fissures. Surface and bore-hole geophysical testing, aquifer tests, and the development of simulative mathematical models will accomplish these goals and permit quantitative evaluations of the potential deleterious effects resulting from development of the water supply. (Woodard-USGS)

  2. Transcriptional response of Desulfatibacillum alkenivorans AK-01 to growth on alkanes: insights from RT-qPCR and microarray analyses.

    PubMed

    Herath, Anjumala; Wawrik, Boris; Qin, Yujia; Zhou, Jizhong; Callaghan, Amy V

    2016-05-01

    Microbial transformation of n-alkanes in anaerobic ecosystems plays a pivotal role in biogeochemical carbon cycling and bioremediation, but the requisite genetic machinery is not well elucidated.Desulfatibacillum alkenivorans AK-01 utilizes n-alkanes (C13 to C18) and contains two genomic loci encoding alkylsuccinate synthase (ASS) gene clusters. ASS catalyzes alkane addition to fumarate to form methylalkylsuccinic acids. We hypothesized that the genes in the two clusters would be differentially expressed depending on the alkane substrate utilized for growth. RT-qPCR was used to investigate ass-gene expression across AK-01's known substrate range, and microarray-based transcriptomic analysis served to investigate whole-cell responses to growth on n-hexadecane versus hexadecanoate. RT-qPCR revealed induction of ass gene cluster 1 during growth on all tested alkane substrates, and the transcriptional start sites in cluster 1 were determined via 5'RACE. Induction of ass gene cluster 2 was not observed under the tested conditions. Transcriptomic analysis indicated that the upregulation of genes potentially involved in methylalkylsuccinate metabolism, including methylmalonyl-CoA mutase and a putative carboxyl transferase. These findings provide new directions for studying the transcriptional regulation of genes involved in alkane addition to fumarate, fumarate recycling and the processing of methylalkylsuccinates with regard to isolates, enrichment cultures and ecological datasets.

  3. Transcriptional response of Desulfatibacillum alkenivorans AK-01 to growth on alkanes: insights from RT-qPCR and microarray analyses.

    PubMed

    Herath, Anjumala; Wawrik, Boris; Qin, Yujia; Zhou, Jizhong; Callaghan, Amy V

    2016-05-01

    Microbial transformation of n-alkanes in anaerobic ecosystems plays a pivotal role in biogeochemical carbon cycling and bioremediation, but the requisite genetic machinery is not well elucidated.Desulfatibacillum alkenivorans AK-01 utilizes n-alkanes (C13 to C18) and contains two genomic loci encoding alkylsuccinate synthase (ASS) gene clusters. ASS catalyzes alkane addition to fumarate to form methylalkylsuccinic acids. We hypothesized that the genes in the two clusters would be differentially expressed depending on the alkane substrate utilized for growth. RT-qPCR was used to investigate ass-gene expression across AK-01's known substrate range, and microarray-based transcriptomic analysis served to investigate whole-cell responses to growth on n-hexadecane versus hexadecanoate. RT-qPCR revealed induction of ass gene cluster 1 during growth on all tested alkane substrates, and the transcriptional start sites in cluster 1 were determined via 5'RACE. Induction of ass gene cluster 2 was not observed under the tested conditions. Transcriptomic analysis indicated that the upregulation of genes potentially involved in methylalkylsuccinate metabolism, including methylmalonyl-CoA mutase and a putative carboxyl transferase. These findings provide new directions for studying the transcriptional regulation of genes involved in alkane addition to fumarate, fumarate recycling and the processing of methylalkylsuccinates with regard to isolates, enrichment cultures and ecological datasets. PMID:27009900

  4. New computer architectures

    SciTech Connect

    Tiberghien, J.

    1984-01-01

    This book presents papers on supercomputers. Topics considered include decentralized computer architecture, new programming languages, data flow computers, reduction computers, parallel prefix calculations, structural and behavioral descriptions of digital systems, instruction sets, software generation, personal computing, and computer architecture education.

  5. Computer vision

    NASA Technical Reports Server (NTRS)

    Gennery, D.; Cunningham, R.; Saund, E.; High, J.; Ruoff, C.

    1981-01-01

    The field of computer vision is surveyed and assessed, key research issues are identified, and possibilities for a future vision system are discussed. The problems of descriptions of two and three dimensional worlds are discussed. The representation of such features as texture, edges, curves, and corners are detailed. Recognition methods are described in which cross correlation coefficients are maximized or numerical values for a set of features are measured. Object tracking is discussed in terms of the robust matching algorithms that must be devised. Stereo vision, camera control and calibration, and the hardware and systems architecture are discussed.

  6. Application of three-dimensional computed tomography in craniofacial clinical practice and research.

    PubMed

    Anderson, P J; Yong, R; Surman, T L; Rajion, Z A; Ranjitkar, S

    2014-06-01

    Following the invention of the first computed tomography (CT) scanner in the early 1970s, many innovations in three-dimensional (3D) diagnostic imaging technology have occurred, leading to a wide range of applications in craniofacial clinical practice and research. Three-dimensional image analysis provides superior and more detailed information compared with conventional plain two-dimensional (2D) radiography, with the added benefit of 3D printing for preoperative treatment planning and regenerative therapy. Current state-of-the-art multidetector CT (MDCT), also known as medical CT, has an important role in the diagnosis and management of craniofacial injuries and pathology. Three-dimensional cone beam CT (CBCT), pioneered in the 1990s, is gaining increasing popularity in dental and craniofacial clinical practice because of its faster image acquisition at a lower radiation dose, but sound guidelines are needed to ensure its optimal clinical use. Recent innovations in micro-computed tomography (micro-CT) have revolutionized craniofacial biology research by enabling higher resolution scanning of teeth beyond the capabilities of MDCT and CBCT, presenting new prospects for translational clinical research. Even after four decades of refinement, CT technology continues to advance and broaden the horizons of craniofacial clinical practice and phenomics research. PMID:24611727

  7. Computational crystallization.

    PubMed

    Altan, Irem; Charbonneau, Patrick; Snell, Edward H

    2016-07-15

    Crystallization is a key step in macromolecular structure determination by crystallography. While a robust theoretical treatment of the process is available, due to the complexity of the system, the experimental process is still largely one of trial and error. In this article, efforts in the field are discussed together with a theoretical underpinning using a solubility phase diagram. Prior knowledge has been used to develop tools that computationally predict the crystallization outcome and define mutational approaches that enhance the likelihood of crystallization. For the most part these tools are based on binary outcomes (crystal or no crystal), and the full information contained in an assembly of crystallization screening experiments is lost. The potential of this additional information is illustrated by examples where new biological knowledge can be obtained and where a target can be sub-categorized to predict which class of reagents provides the crystallization driving force. Computational analysis of crystallization requires complete and correctly formatted data. While massive crystallization screening efforts are under way, the data available from many of these studies are sparse. The potential for this data and the steps needed to realize this potential are discussed.

  8. Computational Astrophysics

    NASA Astrophysics Data System (ADS)

    Mickaelian, A. M.; Astsatryan, H. V.

    2015-07-01

    Present astronomical archives that contain billions of objects, both Galactic and extragalactic, and the vast amount of data on them allow new studies and discoveries. Astrophysical Virtual Observatories (VO) use available databases and current observing material as a collection of interoperating data archives and software tools to form a research environment in which complex research programs can be conducted. Most of the modern databases give at present VO access to the stored information, which makes possible also a fast analysis and managing of these data. Cross-correlations result in revealing new objects and new samples. Very often dozens of thousands of sources hide a few very interesting ones that are needed to be discovered by comparison of various physical characteristics. VO is a prototype of Grid technologies that allows distributed data computation, analysis and imaging. Particularly important are data reduction and analysis systems: spectral analysis, SED building and fitting, modelling, variability studies, cross correlations, etc. Computational astrophysics has become an indissoluble part of astronomy and most of modern research is being done by means of it.

  9. Microcalcifications in the breast detected by a color Doppler method using twinkling artifacts: some important discussions based on clinical cases and experiments with a new ultrasound modality called multidetector-ultrasonography (MD-US).

    PubMed

    Tsujimoto, Fumio

    2014-01-01

    The twinkling artifact is well known as a color Doppler artifact but it is still an unresolved phenomenon [Rahmouni et al., Radiology 1996;199:269-271 ; Atan et al., Astas Urol Esp 2001;35:396-402; Kamaya et al., AJR 2003;80:215-222]. Many factors affect the appearance of the twinkling artifact, such as the surface roughness of stones creating multiple reflections and a form of intrinsic noise known as clock jitter within the Doppler circuitry of the ultrasound equipment. However, no studies have reported on the twinkling artifact of breast microcalcifications. While considering these premises, I detected microcalcifications in the breast using twinkling artifacts that could not be detected on B-mode imaging. The twinkling artifact is a well-defined but not well-understood phenomenon that may assist in the detection of calcified foci. The phenomenon of the twinkling artifact is discussed here with regard to prospectively and retrospectively studied cases including experiments with a new ultrasound modality called multidetector-ultrasonography (MD-US). MD-US using detectability of the twinkling artifact in microcalcifications of the breast may play an important role in breast screening.

  10. Microcalcifications in the breast detected by a color Doppler method using twinkling artifacts: some important discussions based on clinical cases and experiments with a new ultrasound modality called multidetector-ultrasonography (MD-US).

    PubMed

    Tsujimoto, Fumio

    2014-01-01

    The twinkling artifact is well known as a color Doppler artifact but it is still an unresolved phenomenon [Rahmouni et al., Radiology 1996;199:269-271 ; Atan et al., Astas Urol Esp 2001;35:396-402; Kamaya et al., AJR 2003;80:215-222]. Many factors affect the appearance of the twinkling artifact, such as the surface roughness of stones creating multiple reflections and a form of intrinsic noise known as clock jitter within the Doppler circuitry of the ultrasound equipment. However, no studies have reported on the twinkling artifact of breast microcalcifications. While considering these premises, I detected microcalcifications in the breast using twinkling artifacts that could not be detected on B-mode imaging. The twinkling artifact is a well-defined but not well-understood phenomenon that may assist in the detection of calcified foci. The phenomenon of the twinkling artifact is discussed here with regard to prospectively and retrospectively studied cases including experiments with a new ultrasound modality called multidetector-ultrasonography (MD-US). MD-US using detectability of the twinkling artifact in microcalcifications of the breast may play an important role in breast screening. PMID:27277641

  11. Computational introspection

    SciTech Connect

    Batali, J.

    1983-02-01

    Introspection is the process of thinking about one's own thoughts and feelings. In this paper, the author discusses recent attempts to make computational systems that exhibit introspective behavior. Each presents a system capable of manipulating representations of its own program and current context. He argues that introspective ability is crucial for intelligent systems--without it an agent cannot represent certain problems that it must be able to solve. A theory of intelligent action would describe how and why certain actions intelligently achieve an agent's goals. The agent would both embody and represent this theory: it would be implemented as the program for the agent; and the importance of introspection suggests that the agent represent its theory of action to itself.

  12. Computer vision

    SciTech Connect

    Not Available

    1982-01-01

    This paper discusses material from areas such as artificial intelligence, psychology, computer graphics, and image processing. The intent is to assemble a selection of this material in a form that will serve both as a senior/graduate-level academic text and as a useful reference to those building vision systems. This book has a strong artificial intelligence flavour, emphasising the belief that both the intrinsic image information and the internal model of the world are important in successful vision systems. The book is organised into four parts, based on descriptions of objects at four different levels of abstraction. These are: generalised images-images and image-like entities; segmented images-images organised into subimages that are likely to correspond to interesting objects; geometric structures-quantitative models of image and world structures; relational structures-complex symbolic descriptions of image and world structures. The book contains author and subject indexes.

  13. Integrated Airborne and In-Situ Measurements over Land-Fast Ice near Barrow, AK.

    NASA Astrophysics Data System (ADS)

    Brozena, J. M.; Gardner, J. M.; Liang, R.; Ball, D.; Richter-Menge, J.; Claffey, K. J.; Abelev, A.; Hebert, D. A.; Jones, K.

    2014-12-01

    During March of 2014, the Naval Research Laboratory and the Cold Regions Research and Engineering Laboratory collected an integrated set of airborne and in-situ measurements over two areas of floating, but land-fast ice near the coast of Barrow, AK. The near-shore site was just north of Point Barrow, and the "offshore" site was ~ 20 km east of Point Barrow. The in-situ data provided ground-truth for airborne measurements from a scanning LiDAR (Riegl Q 560i), digital photogrammetry (Applanix DSS-439) and a snow radar procured from the Center for Remote Sensing of Ice Sheets of the University of Kansas. The objective of the survey was to aid our understanding of the use of the airborne data to calibrate/validate Cryosat-2 data. Sampling size or "footprint" plays a critical role in the attempt to compare in-situ measurements with airborne (or satellite) measurements. Thus the in-situ data were arranged to minimize aliasing. Ground measurements were collected along transects at both sites consisting of a 2 km long profile of snow depth and ice thickness measurements with periodic boreholes. A 60 m x 400 m swath of snow depth measurements was centered on this profile. Airborne data were collected on five overflights of the two transect areas. The LiDAR measured total freeboard (ice + snow) referenced to leads in the ice, and produced swaths 200-300 m wide. The radar measured snow thickness. The freeboard and snow thickness measurements are used to estimate ice thickness via isostasy and density estimates. The central swath of in situ snow depth data allows examination of the effects of cross-track variations considering the relatively large footprint of the snow radar. Assuming a smooth, flat surface the radar range resolution in air is < 4 cm, but the along-track sampling distance is ~ 3 m after unfocussed SAR processing. The width of the footprint varies from ~ 9 m up to about 40 m (beam-limited) for uneven surfaces. However, the radar could not resolve snow thickness

  14. Integrated Airborne and In-Situ Measurements Over Land-Fast Ice Near Barrow, AK.

    NASA Astrophysics Data System (ADS)

    Gardner, J. M.; Brozena, J. M.; Richter-Menge, J.; Abelev, A.; Liang, R.; Ball, D.; Claffey, K. J.; Hebert, D. A.; Jones, K.

    2015-12-01

    The Naval Research Laboratory has collected two field seasons of integrated airborne and in-situ measurements over multiple sites of floating, but land-fast ice north of Barrow, AK. During the first season in March of 2014 the Cold Regions Research and Engineering Laboratory led the on-ice group including NRL personnel and Naval Academy midshipmen. The second season (March 2015) included only NRL scientists and midshipmen. The in-situ data provided ground-truth for airborne measurements from a scanning LiDAR (Riegl Q 560i), digital photogrammetry (Applanix DSS-439), a low-frequency SAR (P-band in 2014 and P and L bands in 2015) and a snow/Ku radar procured from the Center for Remote Sensing of Ice Sheets of the University of Kansas. The CReSIS radar was updated in 2015 to integrate the snow and Ku radars into a single continuous chirp, thus improving resolution. The objective of the survey was to aid our understanding of the use of the airborne data to calibrate/validate Cryosat-2 data. Sampling size or "footprint" plays a critical role in the attempt to compare in-situ measurements with airborne (or satellite) measurements. Thus the in-situ data were arranged to minimize aliasing. Ground measurements were collected along transects a sites generally consisting of a 2 km long profile of Magnaprobe and EM31 measurements with periodic boreholes. A 60 m x 400 m swath of Magnaprobe measurements was centered on this profile. Airborne data were collected on multiple overflights of the transect areas. The LiDAR measured total freeboard (ice + snow) referenced to leads in the ice, and produced swaths 200-300 m wide. The SAR imaged the ice beneath the snow and the snow/Ku radar measured snow thickness. The freeboard measurements and snow thickness are used to estimate ice thickness via isostasy and density estimates. Comparisons and processing methodology will be shown. The results of this ground-truth experiment will inform our analysis of grids of airborne data collected

  15. Purification and properties of gamma-butyrobetaine hydroxylase from Pseudomonas sp AK 1.

    PubMed

    Lindstedt, G; Lindstedt, S; Nordin, I

    1977-05-17

    gamma-Butyrobetaine hydroxylase (4-trimethylaminobutyrate, 2-oxoglutarate:oxygen oxidoreductase (3-hydroxylating), EC 1.14.11.1) has been isolated from Pseudomonas sp AK 1 by ion-exchange, adsorption, and molecular-sieving chromatography. The preparation was homogeneous as judged from electrophoresis in agarose and polyacrylamide gels, isoelectric focusing, and equilibrium sedimentation. The molecular mass was 95 kdaltons as determined by sedimentation equilibrium centrifugation. From electrophoresis in polyacrylamide gel the molecular mass was estimated to 92 kdaltons, from gel filtration through columns of Sephadex G-200 to 86 kdaltons, and from gel filtration through thin layers of Sephadex G-150 and G-200 to 82 kdaltons. Calculation of molecular mass from Stokes radius, sedimentation coefficient, and partial specific volume gave a value of 96 kdaltons, and from the sedimentation coefficient, 93 kdaltons. Gel filtration through Sephadex G-200 in 6 M guanidinium chloride and electrophoresis in polyacrylamide gel containing 3.5 mM sodium dodecyl sulfate resulted in single bands with mobilities corresponding to molecular masses of 39 and 37 kdaltons, respectively, indicating that the enzyme is composed of two polypeptides chains with similar size. NH2-terminal amino acid sequencing in three cycles resulted in two amino acids in each cycle (Ala + Asn, Ala + Ile, Ala + Ile). The Stokes radius was 3.8 nm, corresponding to a diffusion coefficient of 5.7 X 10(-7) cm2/s. A sedimentation coefficient of 5.8 X 10(-13) s and a frictional ratio of 1.26 was found. The partial specific volume was 0.729 mL/g at 20 degrees C as calculated from amino acid analysis. The isoelectric point was 5.1, as determined by isoelectric focusing analysis. The light absorption in the ultraviolet and visible regions was that of a protein without light-absorbing prosthetic groups. The absorption coefficient at 280 nm of a 1.0% solution at pH 6.5 was 12.6. Amino acid analysis by ion

  16. Monte Carlo calculation of patient organ doses from computed tomography.

    PubMed

    Oono, Takeshi; Araki, Fujio; Tsuduki, Shoya; Kawasaki, Keiichi

    2014-01-01

    In this study, we aimed to evaluate quantitatively the patient organ dose from computed tomography (CT) using Monte Carlo calculations. A multidetector CT unit (Aquilion 16, TOSHIBA Medical Systems) was modeled with the GMctdospp (IMPS, Germany) software based on the EGSnrc Monte Carlo code. The X-ray spectrum and the configuration of the bowtie filter for the Monte Carlo modeling were determined from the chamber measurements for the half-value layer (HVL) of aluminum and the dose profile (off-center ratio, OCR) in air. The calculated HVL and OCR were compared with measured values for body irradiation with 120 kVp. The Monte Carlo-calculated patient dose distribution was converted to the absorbed dose measured by a Farmer chamber with a (60)Co calibration factor at the center of a CT water phantom. The patient dose was evaluated from dose-volume histograms for the internal organs in the pelvis. The calculated Al HVL was in agreement within 0.3% with the measured value of 5.2 mm. The calculated dose profile in air matched the measured value within 5% in a range of 15 cm from the central axis. The mean doses for soft tissues were 23.5, 23.8, and 27.9 mGy for the prostate, rectum, and bladder, respectively, under exposure conditions of 120 kVp, 200 mA, a beam pitch of 0.938, and beam collimation of 32 mm. For bones of the femur and pelvis, the mean doses were 56.1 and 63.6 mGy, respectively. The doses for bone increased by up to 2-3 times that of soft tissue, corresponding to the ratio of their mass-energy absorption coefficients.

  17. Advanced Computing for Medicine.

    ERIC Educational Resources Information Center

    Rennels, Glenn D.; Shortliffe, Edward H.

    1987-01-01

    Discusses contributions that computers and computer networks are making to the field of medicine. Emphasizes the computer's speed in storing and retrieving data. Suggests that doctors may soon be able to use computers to advise on diagnosis and treatment. (TW)

  18. Computer security in DOE distributed computing systems

    SciTech Connect

    Hunteman, W.J.

    1990-01-01

    The modernization of DOE facilities amid limited funding is creating pressure on DOE facilities to find innovative approaches to their daily activities. Distributed computing systems are becoming cost-effective solutions to improved productivity. This paper defines and describes typical distributed computing systems in the DOE. The special computer security problems present in distributed computing systems are identified and compared with traditional computer systems. The existing DOE computer security policy supports only basic networks and traditional computer systems and does not address distributed computing systems. A review of the existing policy requirements is followed by an analysis of the policy as it applies to distributed computing systems. Suggested changes in the DOE computer security policy are identified and discussed. The long lead time in updating DOE policy will require guidelines for applying the existing policy to distributed systems. Some possible interim approaches are identified and discussed. 2 refs.

  19. Observations of ClO during springtime in Barrow, AK from the OASIS 2009 and BROMEX 2012 field campaigns

    NASA Astrophysics Data System (ADS)

    Custard, K. D.; Stephens, C. R.; Pratt, K. A.; Halfacre, J. W.

    2012-12-01

    Reactive halogens species can have significant impacts on tropospheric chemistry and atmospheric composition. In the Arctic, halogen atoms react with tropospheric ozone leading to nearly complete depletion from the ambient atmosphere with consequences on both atmospheric oxidation capacity and radiative forcing. There is much uncertainty about the sources and concentrations of these atmospheric halogens in the Arctic, particularly with respect to chlorine. Recent modeling studies in our laboratory show the potential importance of chlorine atoms during springtime Arctic ozone depletion events. However, ClO measurements in the Arctic have been scarce due to a lack of suitably sensitive analytical techniques. Previous attempts at measuring ClO have used differential optical absorption spectroscopy (DOAS), but chemical interferences at characteristic wavelengths for ClO have resulted in poor limit of detection and large measurement uncertainties. We have developed a method to measure the concentration of ClOx radicals using a flowing chemical reaction technique coupled to an online gas chromatograph with an electron capture detector. This instrumental method was successfully deployed in Barrow, AK during the OASIS (Ocean-Atmosphere-Sea Ice- Snowpack)-2009 field campaign where we obtained t in situ measurements of ClO in the Arctic boundary layer. During the 2012 BRomine, Ozone and Mercury Experiment (BROMEX), also in Barrow, AK this same method was deployed alongside a chemical ionization mass spectrometer that enabled simultaneous measurements of, ClO and Cl2. Here, we present ClO data from both the OASIS and BROMEX field campaigns and an intercomparison of the two methods. The implications of the observed ClO in terms of springtime Arctic tropospheric chemistry will also be discussed.

  20. Computers and occupational therapy.

    PubMed

    English, C B

    1975-01-01

    The benefits and applications of computer science for occupational therapy are explored and a basic, functional description of the computer and computer programming is presented. Potential problems and advantages of computer utilization are compared and examples of existing computer systems in health fields are cited. Methods for successfully introducing computers are discussed.

  1. Significant reduction of left atrial volume concomitant with clinical improvement after percutaneous transluminal septal myocardial ablation for drug-refractory hypertrophic obstructive cardiomyopathy, and its precise detection with multidetector CT

    PubMed Central

    Maekawa, Yuichiro; Akita, Keitaro; Tsuruta, Hikaru; Yamada, Yoshitake; Hayashida, Kentaro; Yuasa, Shinsuke; Murata, Mitsushige; Jinzaki, Masahiro; Fukuda, Keiichi

    2016-01-01

    Objective In patients with hypertrophic obstructive cardiomyopathy (HOCM), left atrial (LA) volume measurement is very important to provide prognostic information. Recent studies demonstrated that multidetector CT (MDCT) is useful to assess the changes in LA volume. Our aim was to examine the utility of a follow-up cardiac MDCT for long-term evaluation of the effect of percutaneous transluminal septal myocardial ablation (PTSMA) on LA volume. Methods We studied a consecutive cohort of 20 patients with drug-refractory symptomatic HOCM after PTSMA. We evaluated LA volume analyses with cardiac MDCT on patients who underwent PTSMA as compared to echocardiography. Results Before PTSMA, 75% of all patients had heart failure-associated symptoms in the New York Heart Association functional class III/IV. All patients experienced relief from heart failure-associated symptoms after PTSMA. Cardiac MDCT showed significant reduction in the index of maximum LA volume during follow-up compared to before PTSMA in the same way as in echocardiography (93.6±34.1 mL/m2 vs 82.6±35.3 mL/m2, p=0.035). A Bland-Altman plot showed small mean differences and limits of agreement in the measurements of the index of maximum LA volume before and after PTSMA between echocardiography and MDCT. Conclusions The follow-up cardiac MDCT was a useful tool to evaluate the effectiveness of PTSMA on reduction of LA volume. Cardiac MDCT might provide comparable measurements of the LA volume in patients with drug-refractory symptomatic HOCM before and after PTSMA compared to echocardiography. PMID:27307994

  2. Detergent-, solvent- and salt-compatible thermoactive alkaline serine protease from halotolerant alkaliphilic Bacillus sp. NPST-AK15: purification and characterization.

    PubMed

    Ibrahim, Abdelnasser S S; Al-Salamah, Ali A; El-Badawi, Yahya B; El-Tayeb, Mohamed A; Antranikian, Garabed

    2015-09-01

    Alkaline protease produced by the halotolerant alkaliphilic Bacillus sp. strain NPST-AK15 was purified to homogeneity by the combination of ammonium sulfate precipitation, anion-exchange and gel permeation chromatography. The purified enzyme was a monomeric protein with an estimated molecular weight of 32 kDa. NPST-AK15 protease was highly active and stable over a wide pH range, with a maximal activity at pH 10.5. The enzyme showed optimum activity at 60 °C and was stable at 30-50 °C for at least 1 h. Thermal stability of the purified protease was substantially improved by CaCl2 (1.1- to 6.6-fold). The K m, V max and k cat values for the enzyme were 2.5 mg ml(-1), 42.5 µM min(-1) mg(-1), and 392.46 × 10(3) min(-1), respectively. NPST-AK15 protease activity was strongly inhibited by PMSF, suggesting that the enzyme is a serine protease. The enzyme was highly stable in NaCl up to 20 % (w/v). Moreover, the purified enzyme was stable in several organic solvents such as diethyl ether, benzene, toluene, and chloroform. In addition, it showed high stability and compatibility with a wide range of surfactants and commercial detergents and was slightly activated by hydrogen peroxide. These features of NPST-AK15 protease make this enzyme a promising candidate for application in the laundry and pharmaceutical industries.

  3. Scanning protocol optimization and dose evaluation in coronary stenosis using multi-slices computed tomography

    NASA Astrophysics Data System (ADS)

    Huang, Yung-hui; Chen, Chia-lin; Sheu, Chin-yin; Lee, Jason J. S.

    2007-02-01

    Cardiovascular diseases are the most common incidence for premature death in developed countries. A major fraction is attributable to atherosclerotic coronary artery disease, which may result in sudden cardiac failure. A reduction of mortality caused by myocardial infarction may be achieved if coronary atherosclerosis can be detected and treated at an early stage before symptoms occur. Therefore, there is need for an effective tool that allows identification of patients at increased risk for future cardiac events. The current multi-detector CT has been widely used for detection and quantification of coronary calcifications as a sign of coronary atherosclerosis. The aim of this study is to optimize the diagnostic values and radiation exposure in coronary artery calcium-screening examination using multi-slice CT (MSCT) with different image scan protocols. The radiation exposure for all protocols is evaluated by using computed tomography dose index (CTDI) phantom measurements. We chose an optimal scanning protocol and evaluated patient radiation dose in the MSCT coronary artery screenings and preserved its expecting diagnostic accuracy. These changes make the MSCT have more operation flexibility and provide more diagnostic values in current practice.

  4. Assessing vertebral fracture risk on volumetric quantitative computed tomography by geometric characterization of trabecular bone structure

    NASA Astrophysics Data System (ADS)

    Checefsky, Walter A.; Abidin, Anas Z.; Nagarajan, Mahesh B.; Bauer, Jan S.; Baum, Thomas; Wismüller, Axel

    2016-03-01

    The current clinical standard for measuring Bone Mineral Density (BMD) is dual X-ray absorptiometry, however more recently BMD derived from volumetric quantitative computed tomography has been shown to demonstrate a high association with spinal fracture susceptibility. In this study, we propose a method of fracture risk assessment using structural properties of trabecular bone in spinal vertebrae. Experimental data was acquired via axial multi-detector CT (MDCT) from 12 spinal vertebrae specimens using a whole-body 256-row CT scanner with a dedicated calibration phantom. Common image processing methods were used to annotate the trabecular compartment in the vertebral slices creating a circular region of interest (ROI) that excluded cortical bone for each slice. The pixels inside the ROI were converted to values indicative of BMD. High dimensional geometrical features were derived using the scaling index method (SIM) at different radii and scaling factors (SF). The mean BMD values within the ROI were then extracted and used in conjunction with a support vector machine to predict the failure load of the specimens. Prediction performance was measured using the root-mean-square error (RMSE) metric and determined that SIM combined with mean BMD features (RMSE = 0.82 +/- 0.37) outperformed MDCT-measured mean BMD (RMSE = 1.11 +/- 0.33) (p < 10-4). These results demonstrate that biomechanical strength prediction in vertebrae can be significantly improved through the use of SIM-derived texture features from trabecular bone.

  5. Does preoperative computed tomography reduce the risks associated with re-do cardiac surgery?

    PubMed

    Khan, Nouman U; Yonan, Nizar

    2009-07-01

    A best evidence topic was written according to the structured protocol. The question addressed was whether preoperative computed tomography (CT) scan reduces the risk associated with re-do cardiac surgery. A Medline search revealed 412 papers, of which seven were deemed relevant to the topic. We conclude that preoperative CT angiography using ECG-gated multi-detector scan enables excellent anatomical details of heart, aorta and previous grafts, and highlights high-risk cases due to adherent grafts or ventricle or aortic atherosclerosis. This allows for better risk stratification and change of surgical strategy to reduce the potential risk in patients coming for re-do cardiac surgery. According to published reports, high-risk CT-scan findings in these patients caused clinicians to cancel surgery in up to 13% of cases, while preventive surgical strategies including non-midline approach, peripheral vascular exposure or establishing cardiopulmonary bypass prior to re-sternotomy have been reported in over two-thirds of patients with significant reduction in the operative risk. The risk of damage to vital structures, including previous grafts, heart or larger vessels is generally reported fewer than 10%, with evidence of significantly lower incidence of intra-operative injuries in patients who had prior CT-scans compared to those who did not. Hence, adequate preoperative imaging using ECG-gated multi-slice CT is essential for optimum planning of re-do cardiac surgery. PMID:19339275

  6. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    NASA Astrophysics Data System (ADS)

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  7. COMPUTED TOMOGRAPHIC AND ULTRASONOGRAPHIC CHARACTERISTICS OF CAVERNOUS TRANSFORMATION OF THE OBSTRUCTED PORTAL VEIN IN SMALL ANIMALS.

    PubMed

    Specchi, Swan; Pey, Pascaline; Ledda, Gianluca; Lustgarten, Meghann; Thrall, Donald; Bertolini, Giovanna

    2015-01-01

    In humans, the process of development of collateral vessels with hepatopetal flow around the portal vein in order to bypass an obstruction is called "cavernous transformation of the portal vein." The purpose of this retrospective, cross-sectional, multicentric study was to describe presumed cavernous transformation of the portal vein in small animals with portal vein obstruction using ultrasound and multidetector-row computed tomography (MDCT). Databases from three different institutions were searched for patients with an imaging diagnosis of cavernous transformation of the portal vein secondary to portal vein obstruction of any cause. Images were retrieved and reanalyzed. With MDCT-angiography, two main portoportal collateral pathways were identified: short tortuous portoportal veins around/inside the thrombus and long portoportal collaterals bypassing the site of portal obstruction. Three subtypes of the long collaterals, often coexisting, were identified. Branches of the hepatic artery where involved in collateral circulation in nine cases. Concomitant acquired portosystemic shunts were identified in six patients. With ultrasound, cavernous transformation of the portal vein was suspected in three dogs and one cat based on visualization of multiple and tortuous vascular structures corresponding to periportal collaterals. In conclusion, the current study provided descriptive MDCT and ultrasonographic characteristics of presumed cavernous transformation of the portal vein in a sample of small animals. Cavernous transformation of the portal vein could occur as a single condition or could be concurrent with acquired portosystemic shunts.

  8. Effective Doses in Four-Dimensional Computed Tomography for Lung Radiotherapy Planning

    SciTech Connect

    Mori, Shinichiro Ko, Susumu; Ishii, Takayoshi; Nishizawa, Kanae

    2009-04-01

    The recent broad adoption of 4-D computed tomography (4DCT) scanning in radiotherapy has allowed the accurate determination of the target volume of tumors by minimizing image degradation caused by respiratory motion. Although the radiation exposure of the treatment beam is significantly greater than that of CT scans used for treatment planning, it is important to recognize and optimize the radiation exposure in 4DCT from the radiological protection point of view. Here, radiation exposure in 4DCT was measured with a 16 multidetector CT. Organ doses were measured using thermoluminescence radiation dosimeter chips inserted at respective anatomical sites of an anthropomorphic phantom. Results were compared with those with the helical CT scan mode. The effective dose measured for 4DCT was 24.7 mSv, approximately four times higher than that for helical CT. However, the increase in treatment accuracy afforded by 4DCT means its use in radiotherapy is inevitable. The patient exposure in the 4DCT could be of value by clarifying the advantage of the treatment planning using 4DCT.

  9. COMPUTED TOMOGRAPHIC AND ULTRASONOGRAPHIC CHARACTERISTICS OF CAVERNOUS TRANSFORMATION OF THE OBSTRUCTED PORTAL VEIN IN SMALL ANIMALS.

    PubMed

    Specchi, Swan; Pey, Pascaline; Ledda, Gianluca; Lustgarten, Meghann; Thrall, Donald; Bertolini, Giovanna

    2015-01-01

    In humans, the process of development of collateral vessels with hepatopetal flow around the portal vein in order to bypass an obstruction is called "cavernous transformation of the portal vein." The purpose of this retrospective, cross-sectional, multicentric study was to describe presumed cavernous transformation of the portal vein in small animals with portal vein obstruction using ultrasound and multidetector-row computed tomography (MDCT). Databases from three different institutions were searched for patients with an imaging diagnosis of cavernous transformation of the portal vein secondary to portal vein obstruction of any cause. Images were retrieved and reanalyzed. With MDCT-angiography, two main portoportal collateral pathways were identified: short tortuous portoportal veins around/inside the thrombus and long portoportal collaterals bypassing the site of portal obstruction. Three subtypes of the long collaterals, often coexisting, were identified. Branches of the hepatic artery where involved in collateral circulation in nine cases. Concomitant acquired portosystemic shunts were identified in six patients. With ultrasound, cavernous transformation of the portal vein was suspected in three dogs and one cat based on visualization of multiple and tortuous vascular structures corresponding to periportal collaterals. In conclusion, the current study provided descriptive MDCT and ultrasonographic characteristics of presumed cavernous transformation of the portal vein in a sample of small animals. Cavernous transformation of the portal vein could occur as a single condition or could be concurrent with acquired portosystemic shunts. PMID:25877678

  10. From macro-scale to micro-scale computational anatomy: a perspective on the next 20 years.

    PubMed

    Mori, Kensaku

    2016-10-01

    This paper gives our perspective on the next two decades of computational anatomy, which has made great strides in the recognition and understanding of human anatomy from conventional clinical images. The results from this field are now used in a variety of medical applications, including quantitative analysis of organ shapes, interventional assistance, surgical navigation, and population analysis. Several anatomical models have also been used in computational anatomy, and these mainly target millimeter-scale shapes. For example, liver-shape models are almost completely modeled at the millimeter scale, and shape variations are described at such scales. Most clinical 3D scanning devices have had just under 1 or 0.5 mm per voxel resolution for over 25 years, and this resolution has not changed drastically in that time. Although Z-axis (head-to-tail direction) resolution has been drastically improved by the introduction of multi-detector CT scanning devices, in-plane resolutions have not changed very much either. When we look at human anatomy, we can see different anatomical structures at different scales. For example, pulmonary blood vessels and lung lobes can be observed in millimeter-scale images. If we take 10-µm-scale images of a lung specimen, the alveoli and bronchiole regions can be located in them. Most work in millimeter-scale computational anatomy has been done by the medical-image analysis community. In the next two decades, we encourage our community to focus on micro-scale computational anatomy. In this perspective paper, we briefly review the achievements of computational anatomy and its impacts on clinical applications; furthermore, we show several possibilities from the viewpoint of microscopic computational anatomy by discussing experimental results from our recent research activities.

  11. The assumptions of computing

    SciTech Connect

    Huggins, J.K.

    1994-12-31

    The use of computers, like any technological activity, is not content-neutral. Users of computers constantly interact with assumptions regarding worthwhile activity which are embedded in any computing system. Directly questioning these assumptions in the context of computing allows us to develop an understanding of responsible computing.

  12. Computers in Teaching English.

    ERIC Educational Resources Information Center

    Davis, James E., Ed.; Davis, Hazel K., Ed.

    1983-01-01

    The 26 articles in this journal issue discuss the use of the computer in the English classroom. Among the topics and applications discussed are (1) computer assisted invention, (2) word processing, (3) overcoming computer anxiety, (4) using computers in technical writing classes, (5) grading student essays by computer, (6) the experiences of an…

  13. The Old Computers' Home.

    ERIC Educational Resources Information Center

    Angier, Natalie

    1983-01-01

    The Computer Museum in Marlborough, Massachusetts houses old and not-so-old calculators, famous old computers and parts of computers, photographs and assorted memorabilia, computer-generated murals, and even a computer made of Tinkertoys that plays tick-tack-toe. The development of the museum and selected exhibits is described. (Author/JN)

  14. Democratizing Computer Science

    ERIC Educational Resources Information Center

    Margolis, Jane; Goode, Joanna; Ryoo, Jean J.

    2015-01-01

    Computer science programs are too often identified with a narrow stratum of the student population, often white or Asian boys who have access to computers at home. But because computers play such a huge role in our world today, all students can benefit from the study of computer science and the opportunity to build skills related to computing. The…

  15. Computers for Everybody.

    ERIC Educational Resources Information Center

    Willis, Jerry; Miller, Merl

    This book explains how computers can be used in the home, office or school, and provides a consumer's guide to computer equipment for the novice user. The first sections of the book offer a brief sketch of computer history, a listing of entertaining and easily available computer programs, a step-by-step guide to buying a computer, and advice on…

  16. GeoComputation 2009

    SciTech Connect

    Xue, Yong; Hoffman, Forrest M; Liu, Dingsheng

    2009-01-01

    The tremendous computing requirements of today's algorithms and the high costs of high-performance supercomputers drive us to share computing resources. The emerging computational Grid technologies are expected to make feasible the creation of a computational environment handling many PetaBytes of distributed data, tens of thousands of heterogeneous computing resources, and thousands of simultaneous users from multiple research institutions.

  17. Tying into Computers.

    ERIC Educational Resources Information Center

    Canipe, Stephen L.

    Topics in this paper include: sources of computer programs, public domain software, copyright violations, purposes of computers in classrooms (drill/practice and interactive learning), computer assisted instruction, flow charts, and computer clubs (such as App-le-kations in Charlotte, North Carolina). A complete listing of two computer programs…

  18. Computational thinking and thinking about computing.

    PubMed

    Wing, Jeannette M

    2008-10-28

    Computational thinking will influence everyone in every field of endeavour. This vision poses a new educational challenge for our society, especially for our children. In thinking about computing, we need to be attuned to the three drivers of our field: science, technology and society. Accelerating technological advances and monumental societal demands force us to revisit the most basic scientific questions of computing.

  19. Computational thinking and thinking about computing

    PubMed Central

    Wing, Jeannette M.

    2008-01-01

    Computational thinking will influence everyone in every field of endeavour. This vision poses a new educational challenge for our society, especially for our children. In thinking about computing, we need to be attuned to the three drivers of our field: science, technology and society. Accelerating technological advances and monumental societal demands force us to revisit the most basic scientific questions of computing. PMID:18672462

  20. Mechanism-Based Screen for G1/S Checkpoint Activators Identifies a Selective Activator of EIF2AK3/PERK Signalling

    PubMed Central

    Barrie, S. Elaine; Zoumpoulidou, Georgia; te Poele, Robert H.; Aherne, G. Wynne; Wilson, Stuart C.; Sheldrake, Peter; McDonald, Edward; Venet, Mathilde; Soudy, Christelle; Elustondo, Frédéric; Rigoreau, Laurent; Blagg, Julian; Workman, Paul; Garrett, Michelle D.; Mittnacht, Sibylle

    2012-01-01

    Human cancers often contain genetic alterations that disable G1/S checkpoint control and loss of this checkpoint is thought to critically contribute to cancer generation by permitting inappropriate proliferation and distorting fate-driven cell cycle exit. The identification of cell permeable small molecules that activate the G1/S checkpoint may therefore represent a broadly applicable and clinically effective strategy for the treatment of cancer. Here we describe the identification of several novel small molecules that trigger G1/S checkpoint activation and characterise the mechanism of action for one, CCT020312, in detail. Transcriptional profiling by cDNA microarray combined with reverse genetics revealed phosphorylation of the eukaryotic initiation factor 2-alpha (EIF2A) through the eukaryotic translation initiation factor 2-alpha kinase 3 (EIF2AK3/PERK) as the mechanism of action of this compound. While EIF2AK3/PERK activation classically follows endoplasmic reticulum (ER) stress signalling that sets off a range of different cellular responses, CCT020312 does not trigger these other cellular responses but instead selectively elicits EIF2AK3/PERK signalling. Phosphorylation of EIF2A by EIF2A kinases is a known means to block protein translation and hence restriction point transit in G1, but further supports apoptosis in specific contexts. Significantly, EIF2AK3/PERK signalling has previously been linked to the resistance of cancer cells to multiple anticancer chemotherapeutic agents, including drugs that target the ubiquitin/proteasome pathway and taxanes. Consistent with such findings CCT020312 sensitizes cancer cells with defective taxane-induced EIF2A phosphorylation to paclitaxel treatment. Our work therefore identifies CCT020312 as a novel small molecule chemical tool for the selective activation of EIF2A-mediated translation control with utility for proof-of-concept applications in EIF2A-centered therapeutic approaches, and as a chemical starting point for