  1. Functional relationship-based alarm processing system

    DOEpatents

    Corsberg, Daniel R.

    1989-01-01

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.

  2. Functional relationship-based alarm processing system

    DOEpatents

    Corsberg, D.R.

    1988-04-22

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the functional relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated or deactivated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary. 12 figs.

  3. Functional relationship-based alarm processing

    DOEpatents

    Corsberg, D.R.

    1987-04-13

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously updated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on causal factors between two alarms); (3) required action (system response or action expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). 11 figs.

  4. Improved process control alarm operation.

    PubMed

    Bristol, E H

    2001-01-01

    Alarms are the main connection from the automation to the operator, when addressing process operation outside of its normal function. They are often as much a source of operator overload and consternation as help. Better engineering of the relative role of the operator and automation would materially help overcome the difficulties. Expert systems have been proposed as a solution. But Expert systems are really another form of automation. There remains that aspect of the alarms, which must address our inability to cover and understand a possibly larger domain of the operation not appropriate to traditional controls or present-day automation. Appropriate tools for this domain must support operator discretion and initiative. The paper suggests a set of such general, computer science based, tools requiring only the most basic configuration. They are viewed as implemented on top of those properly detailed alarm displays and interlocks, which reflect the more formal plant operating policies. They include: (a) Various forms of alarm logging and trending; (b) Short, automatically generated, word summaries of alarm activity, which allow low level data to propagate to the highest levels, including: one word and priority summaries; (c) Causal alarm pattern analyses that help the operator to predict or diagnose alarm behavior; (d) Automatic adaptation of alarms and alarm limits to varying process situations; (e) Uniform use of alarm policies to simplify alarm configuration.

  5. Functional relationship-based alarm processing

    DOEpatents

    Corsberg, Daniel R.

    1988-01-01

    A functional relationship-based alarm processing system and method analyzes each alarm as it is activated and determines its relative importance with other currently activated alarms and signals in accordance with the relationships that the newly activated alarm has with other currently activated alarms. Once the initial level of importance of the alarm has been determined, that alarm is again evaluated if another related alarm is activated. Thus, each alarm's importance is continuously oupdated as the state of the process changes during a scenario. Four hierarchical relationships are defined by this alarm filtering methodology: (1) level precursor (usually occurs when there are two alarm settings on the same parameter); (2) direct precursor (based on caussal factors between two alarms); (3) required action (system response or action) expected within a specified time following activation of an alarm or combination of alarms and process signals); and (4) blocking condition (alarms that are normally expected and are not considered important). The alarm processing system and method is sensitive to the dynamic nature of the process being monitored and is capable of changing the relative importance of each alarm as necessary.

  6. Remote Monitor Alarm System

    NASA Technical Reports Server (NTRS)

    Stute, Robert A. (Inventor); Galloway, F. Houston (Inventor); Medelius, Pedro J. (Inventor); Swindle, Robert W. (Inventor); Bierman, Tracy A. (Inventor)

    1996-01-01

    A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.

  7. VISUAL ALARM SYSTEM

    DOEpatents

    Morris, J.M.

    1958-11-01

    A vlsual alarm system, particularly a system incorporating a gas-fllled diode glow bulb, for indicating a minor alarm and also a major alarm is presented. In operation, the disclosed system responds to a signal indlcative of a caution condition by applying a d-c voltage across the glow bulb to induce a glow at one electrode. If a signal indicative of a critlcal condition is received, the system applies an a-c voltage across tbe glow bulb to produce a glow discharge at each electrode.

  8. Alarm Notification System

    SciTech Connect

    1995-03-12

    AN/EMS, the Alarm Notification Energy Management System, is used to monitor digital sensors in PETC buildings and to notify the safety/security operator by both a video and an audio system when a possibly hazardous condition arises.

  9. Criticality accident alarm system

    SciTech Connect

    Malenfant, R.E.

    1991-01-01

    The American National Standard ANSI/ANS-8.3-1986, Criticality Accident Alarm System provides guidance for the establishment and maintenance of an alarm system to initiate personnel evacuation in the event of inadvertent criticality. In addition to identifying the physical features of the components of the system, the characteristics of accidents of concern are carefully delineated. Unfortunately, this ANSI Standard has led to considerable confusion in interpretation, and there is evidence that the minimum accident of concern'' may not be appropriate. Furthermore, although intended as a guide, the provisions of the standard are being rigorously applied, sometimes with interpretations that are not consistent. Although the standard is clear in the use of absorbed dose in free air of 20 rad, at least one installation has interpreted the requirement to apply to dose in soft tissue. The standard is also clear in specifying the response to both neutrons and gamma rays. An assembly of uranyl fluoride enriched to 5% {sup 235}U was operated to simulate a potential accident. The dose, delivered in a free run excursion 2 m from the surface of the vessel, was greater than 500 rad, without ever exceeding a rate of 20 rad/min, which is the set point for activating an alarm that meets the standard. The presence of an alarm system would not have prevented any of the five major accidents in chemical operations nor is it absolutely certain that the alarms were solely responsible for reducing personnel exposures following the accident. Nevertheless, criticality alarm systems are now the subject of great effort and expense. 13 refs.

  10. FIRE ALARM SYSTEM OUTDATED.

    ERIC Educational Resources Information Center

    CHANDLER, L.T.

    AN EFFICIENT FIRE ALARM SYSTEM SHOULD--(1) PROVIDE WARNING OF FIRES THAT START IN HIDDEN OR UNOCCUPIED LOCATIONS, (2) INDICATE WHERE THE FIRE IS, (3) GIVE ADVANCE WARNING TO FACULTY AND ADMINISTRATION SO THAT PANIC AND CONFUSION CAN BE AVOIDED AND ORDERLY EVACUATION OCCUR, (4) AUTOMATICALLY NOTIFY CITY FIRE HEADQUARTERS OF THE FIRE, (5) OPERATE BY…

  11. IMPEDANCE ALARM SYSTEM

    DOEpatents

    Cowen, R.G.

    1959-09-29

    A description is given of electric protective systems and burglar alarm systems of the capacitance type in which the approach of an intruder at a place to be protected varies the capacitance in an electric circuit and the change is thereafter communicated to a remote point to actuate an alarm. According to the invention, an astable transitor multi-vibrator has the amplitude at its output voltage controlled by a change in the sensing capacitance. The sensing capacitance is effectively connected between collector and base of one stage of the multivibrator circuit through the detector-to-monitor line. The output of the detector is a small d-c voltage across the detector-to-monitor line. This d- c voltage is amplified and monitored at the other end of the line, where an appropriate alarm is actuated if a sudden change in the voltage occurs. The present system has a high degree of sensitivity and is very difficult to defeat by known techniques.

  12. Personal Alarm System

    SciTech Connect

    2015-04-17

    Software that runs on smartphones and desktop web browsers and notifies border officials of radiation alarms. It displays images and data associated with an alarm and provides a variety of reports. DOE had a need for discrete notification. PAS replaces the lights and sounds of a Radiation Portal Monitor.

  13. Substation alarm multiplexing system (SAMS)

    SciTech Connect

    ElBadaly, H.; Gaughan, J.; Ward, G.; Amengual, S.

    1996-03-01

    This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creek substation in the Bronx for the purpose of a three month field evaluation.

  14. Nuclear power plant alarm systems: Problems and issues

    SciTech Connect

    O'Hara, J.M.; Brown, W.S.

    1991-01-01

    Despite the incorporation of advanced technology into nuclear power plant alarm systems, human factors problems remain. This paper identifies to be addressed in order to allow advanced technology to be used effectively in the design of nuclear power plant alarm systems. The operator's use and processing of alarm system information will be considered. Based upon a review of alarm system research, issues related to general system design, alarm processing, display and control are discussed. It is concluded that the design of effective alarm systems depends on an understanding of the information processing capabilities and limitations of the operator. 39 refs.

  15. Classification of alarm processing techniques and human performance issues

    SciTech Connect

    Kim, I.S.; O`Hara, J.M.

    1993-05-01

    Human factors reviews indicate that conventional alarm systems based on the one sensor, one alarm approach, have many human engineering deficiencies, a paramount example being too many alarms during major disturbances. As an effort to resolve these deficiencies, various alarm processing systems have been developed using different techniques. To ensure their contribution to operational safety, the impacts of those systems on operating crew performance should be carefully evaluated. This paper briefly reviews some of the human factors research issues associated with alarm processing techniques and then discusses a framework with which to classify the techniques. The dimensions of this framework can be used to explore the effects of alarm processing systems on human performance.

  16. Classification of alarm processing techniques and human performance issues

    SciTech Connect

    Kim, I.S.; O'Hara, J.M.

    1993-01-01

    Human factors reviews indicate that conventional alarm systems based on the one sensor, one alarm approach, have many human engineering deficiencies, a paramount example being too many alarms during major disturbances. As an effort to resolve these deficiencies, various alarm processing systems have been developed using different techniques. To ensure their contribution to operational safety, the impacts of those systems on operating crew performance should be carefully evaluated. This paper briefly reviews some of the human factors research issues associated with alarm processing techniques and then discusses a framework with which to classify the techniques. The dimensions of this framework can be used to explore the effects of alarm processing systems on human performance.

  17. Intensive care alarm system

    NASA Technical Reports Server (NTRS)

    Christensen, J. L.; Herbert, A. L.

    1973-01-01

    Inductive loop has been added to commercially available call system fitted with earphone receiver. System transmits high frequency signals to nurse's receiver to announce patient's need for help without disturbing others.

  18. Personal Alarm System

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Trouble in the classroom is an unpleasant fact of modern life. Space technology can't stop the trouble from occurring, but it can prevent it from spreading. In recognition of this, NASA and the Sacramento, Cal. Unified School District developed a personal security system based on space telemetry technology. The first application was for schools, but the simplicity and reliability of the system has made it more widely applicable. The heart of the system is an ultrasonic pen-size transmitter. It can be used by prison guards, teachers, or others such as the handicapped and the elderly.

  19. SUBSURFACE VISUAL ALARM SYSTEM ANALYSIS

    SciTech Connect

    D.W. Markman

    2001-08-06

    The ''Subsurface Fire Hazard Analysis'' (CRWMS M&O 1998, page 61), and the document, ''Title III Evaluation Report for the Surface and Subsurface Communication System'', (CRWMS M&O 1999a, pages 21 and 23), both indicate the installed communication system is adequate to support Exploratory Studies Facility (ESF) activities with the exception of the mine phone system for emergency notification purposes. They recommend the installation of a visual alarm system to supplement the page/party phone system The purpose of this analysis is to identify data communication highway design approaches, and provide justification for the selected or recommended alternatives for the data communication of the subsurface visual alarm system. This analysis is being prepared to document a basis for the design selection of the data communication method. This analysis will briefly describe existing data or voice communication or monitoring systems within the ESF, and look at how these may be revised or adapted to support the needed data highway of the subsurface visual alarm. system. The existing PLC communication system installed in subsurface is providing data communication for alcove No.5 ventilation fans, south portal ventilation fans, bulkhead doors and generator monitoring system. It is given that the data communication of the subsurface visual alarm system will be a digital based system. It is also given that it is most feasible to take advantage of existing systems and equipment and not consider an entirely new data communication system design and installation. The scope and primary objectives of this analysis are to: (1) Briefly review and describe existing available data communication highways or systems within the ESF. (2) Examine technical characteristics of an existing system to disqualify a design alternative is paramount in minimizing the number of and depth of a system review. (3) Apply general engineering design practices or criteria such as relative cost, and degree of

  20. The Best Ever Alarm System Toolkit

    SciTech Connect

    Kasemir, Kay; Chen, Xihui; Danilova, Katia

    2009-01-01

    Learning from our experience with the standard Experimental Physics and Industrial Control System (EPICS) alarm handler (ALH) as well as a similar intermediate approach based on script-generated operator screens, we developed the Best Ever Alarm System Toolkit (BEAST). It is based on Java and Eclipse on the Control System Studio (CSS) platform, using a relational database (RDB) to store the configuration and log actions. It employs a Java Message Service (JMS) for communication between the modular pieces of the toolkit, which include an Alarm Server to maintain the current alarm state, an arbitrary number of Alarm Client user interfaces (GUI), and tools to annunciate alarms or log alarm related actions. Web reports allow us to monitor the alarm system performance and spot deficiencies in the alarm configuration. The Alarm Client GUI not only gives the end users various ways to view alarms in tree and table, but also makes it easy to access the guidance information, the related operator displays and other CSS tools. It also allows online configuration to be simply modified from the GUI. Coupled with a good "alarm philosophy" on how to provide useful alarms, we can finally improve the configuration to achieve an effective alarm system.

  1. Video systems for alarm assessment

    SciTech Connect

    Greenwoll, D.A.; Matter, J.C. ); Ebel, P.E. )

    1991-09-01

    The purpose of this NUREG is to present technical information that should be useful to NRC licensees in designing closed-circuit television systems for video alarm assessment. There is a section on each of the major components in a video system: camera, lens, lighting, transmission, synchronization, switcher, monitor, and recorder. Each section includes information on component selection, procurement, installation, test, and maintenance. Considerations for system integration of the components are contained in each section. System emphasis is focused on perimeter intrusion detection and assessment systems. A glossary of video terms is included. 13 figs., 9 tabs.

  2. The alarm system and a possible way forward.

    PubMed

    Alm, Håkan; Osvalder, Anna-Lisa

    2012-01-01

    The aim of this paper is to make a review of studies concerning problems with alarm systems and to make a theoretical analysis of these problems. The aim is also to show some general design ideas to improve alarm presentation in process descriptions. Using research results from situation awareness and decision making a number of suggestions for further development of alarm systems are presented. Recommendations include providing operators of complex systems feedback that can support their mental models and situational awareness. Furthermore a recommendation is to design alarm systems that can learn from experience.

  3. A new method for defining and managing process alarms and for correcting process operation when an alarm occurs.

    PubMed

    Brooks, Robin; Thorpe, Richard; Wilson, John

    2004-11-11

    A new mathematical treatment of alarms that considers them as multi-variable interactions between process variables has provided the first-ever method to calculate values for alarm limits. This has resulted in substantial reductions in false alarms and hence in alarm annunciation rates in field trials. It has also unified alarm management, process control and product quality control into a single mathematical framework so that operations improvement and hence economic benefits are obtained at the same time as increased process safety. Additionally, an algorithm has been developed that advises what changes should be made to Manipulable process variables to clear an alarm. The multi-variable Best Operating Zone at the heart of the method is derived from existing historical data using equation-free methods. It does not require a first-principles process model or an expensive series of process identification experiments. Integral with the method is a new format Process Operator Display that uses only existing variables to fully describe the multi-variable operating space. This combination of features makes it an affordable and maintainable solution for small plants and single items of equipment as well as for the largest plants. In many cases, it also provides the justification for the investments about to be made or already made in process historian systems. Field Trials have been and are being conducted at IneosChlor and Mallinckrodt Chemicals, both in the UK, of the new geometric process control (GPC) method for improving the quality of both process operations and product by providing Process Alarms and Alerts of much high quality than ever before. The paper describes the methods used, including a simple visual method for Alarm Rationalisation that quickly delivers large sets of Consistent Alarm Limits, and the extension to full Alert Management with highlights from the Field Trials to indicate the overall effectiveness of the method in practice.

  4. Alarm system for a nuclear control complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  5. 46 CFR 113.20-1 - Sprinkler alarm system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Sprinkler alarm system. 113.20-1 Section 113.20-1... ALARM SYSTEMS AND EQUIPMENT Automatic Sprinkler Systems § 113.20-1 Sprinkler alarm system. Each sprinkler alarm system, including annunciator, power supply, alarm switches, and bells, must meet Subpart...

  6. Evaluation of alarm systems for medical equipment.

    PubMed

    Hyman, W A

    1982-01-01

    The provision of automatic alarm systems on medical equipment is generally designed to supplement the user's ability to monitor a variety of device and patient variables simultaneously. The potential value of such systems in improving the safety and efficacy of medical care is accompanied by the potential for false reliance on or other misuse of the alarm systems. Therefore the alarm provisions become an important aspect of clinical engineering assessment of equipment with respect to selection, user training, hazard analysis, and the provision of effective and appropriate preventive maintenance programs.

  7. HYBRID ALARM SYSTEMS: COMBINING SPATIAL ALARMS AND ALARM LISTS FOR OPTIMIZED CONTROL ROOM OPERATION

    SciTech Connect

    Ronald L. Boring; J.J. Persensky

    2012-07-01

    The US Department of Energy (DOE) is sponsoring research, development, and deployment on Light Water Reactor Sustainability (LWRS), in which the Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe operational life extension of current nuclear power plants. One of the main areas of focus is control room modernization. Within control room modernization, alarm system upgrades present opportunities to meet the broader goals of the LWRS project in demonstrating the use and safety of the advanced instrumentation and control (I&C) technologies and the short-term and longer term objectives of the plant. In this paper, we review approaches for and human factors issues behind upgrading alarms in the main control room of nuclear power plants.

  8. Automated Information System (AIS) Alarm System

    SciTech Connect

    Hunteman, W.

    1997-05-01

    The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, the assessment criteria, and the desired responses may be set by the using organization to meet their local security policies.

  9. Alarm Systems: Library Confounds Criminal Capers.

    ERIC Educational Resources Information Center

    Gjettum, Pamela

    1978-01-01

    Tells the story of a small town library faced with the problem of preventing nuisance burglaries of the type becoming more and more common. The problems of selecting the right type of alarm system are discussed. (JPF)

  10. Computational Human Performance Modeling For Alarm System Design

    SciTech Connect

    Jacques Hugo

    2012-07-01

    The introduction of new technologies like adaptive automation systems and advanced alarms processing and presentation techniques in nuclear power plants is already having an impact on the safety and effectiveness of plant operations and also the role of the control room operator. This impact is expected to escalate dramatically as more and more nuclear power utilities embark on upgrade projects in order to extend the lifetime of their plants. One of the most visible impacts in control rooms will be the need to replace aging alarm systems. Because most of these alarm systems use obsolete technologies, the methods, techniques and tools that were used to design the previous generation of alarm system designs are no longer effective and need to be updated. The same applies to the need to analyze and redefine operators’ alarm handling tasks. In the past, methods for analyzing human tasks and workload have relied on crude, paper-based methods that often lacked traceability. New approaches are needed to allow analysts to model and represent the new concepts of alarm operation and human-system interaction. State-of-the-art task simulation tools are now available that offer a cost-effective and efficient method for examining the effect of operator performance in different conditions and operational scenarios. A discrete event simulation system was used by human factors researchers at the Idaho National Laboratory to develop a generic alarm handling model to examine the effect of operator performance with simulated modern alarm system. It allowed analysts to evaluate alarm generation patterns as well as critical task times and human workload predicted by the system.

  11. Alarms Philosophy

    SciTech Connect

    White, Karen S; Kasemir, Kay

    2009-01-01

    An effective alarm system consists of a mechanism to monitor control points and generate alarm notifications, tools for operators to view, hear, acknowledge and handle alarms and a good configuration. Despite the availability of numerous fully featured tools, accelerator alarm systems continue to be disappointing to operations, frequently to the point of alarms being permanently silenced or totally ignored. This is often due to configurations that produce an excessive number of alarms or fail to communicate the required operator response. Most accelerator controls systems do a good job of monitoring specified points and generating notifications when parameters exceed predefined limits. In some cases, improved tools can help, but more often, poor configuration is the root cause of ineffective alarm systems. A SNS, we have invested considerable effort in generating appropriate configurations using a rigorous set of rules based on best practices in the industrial process controls community. This paper will discuss our alarm configuration philosophy and operator response to our new system.

  12. Perimeter security alarm system based on fiber Bragg grating

    NASA Astrophysics Data System (ADS)

    Zhang, Cui; Wang, Lixin

    2010-11-01

    With the development of the society and economy and the improvement of living standards, people need more and more pressing security. Perimeter security alarm system is widely regarded as the first line of defense. A highly sensitive Fiber Bragg grating (FBG) vibration sensor based on the theory of the string vibration, combined with neural network adaptive dynamic programming algorithm for the perimeter security alarm system make the detection intelligently. Intelligent information processing unit identify the true cause of the vibration of the invasion or the natural environment by analyzing the frequency of vibration signals, energy, amplitude and duration. Compared with traditional perimeter security alarm systems, such as infrared perimeter security system and electric fence system, FBG perimeter security alarm system takes outdoor passive structures, free of electromagnetic interference, transmission distance through optical fiber can be as long as 20 km It is able to detect the location of event within short period of time (high-speed response, less than 3 second).This system can locate the fiber cable's breaking sites and alarm automatically if the cable were be cut. And the system can prevent effectively the false alarm from small animals, birds, strong wind, scattering things, snowfalls and vibration of sensor line itself. It can also be integrated into other security systems. This system can be widely used in variety fields such as military bases, nuclear sites, airports, warehouses, prisons, residence community etc. It will be a new force of perimeter security technology.

  13. Onsite Portable Alarm System - Its Merit and Application

    NASA Astrophysics Data System (ADS)

    Saita, J.; Sato, T.; Nakamura, Y.

    2007-12-01

    Recently an existence of the earthquake early warning system (EEWS) becomes popular. In general, the EEWS will be installed in a fixed observation site and it may consist of several separated components such as a sensing portion, A/D converter, an information processing potion and so on. The processed information for warning may be transmitted to network via fixed communication line, and therefore this kind of alarm system is called as Network Alarm System. On the other hand, after the severe earthquake damage, it is very important to save the disaster victims immediately. These rescue staffs are also under the risk of aftershocks and need a local alarm not depending on the network, so this kind of alarm can be called as Onsite Alarm. But the common early warning system is too complex to set onsite temporary, and even if possible to install, the alarm is too late to receive at the epicentral area. However, the new generation earthquake early warning system FREQL can issue the P wave alarm by minimum 0.2 seconds after P wave detection. And FREQL is characterized as the unique all-in-one seismometer with power unit. At the time of the 2004 Niigata-Ken-Chuetsu earthquake, a land slide attacked a car just passing. A hyper rescue team of Tokyo Fire Department pulled the survivor, one baby, from the land slide area. During their activity the rescue team was exposed to the risk of secondary hazards caused by the aftershocks. It was clear that it is necessary to use a portable warning system to issue the onsite P wave alarm. Because FREQL was originally developed as portable equipment, Tokyo Fire Department asked us to modify it to the portable equipment with the loud sound and the light signal. In this moment, this portable FREQL has equipped in nation wide. When the hyper rescue team of Tokyo Fire Department was sent to Pakistan as a task force for rescue work of the 2005 Pakistan earthquake, the portable FREQL was used as important onsite portable warning system and P

  14. An experimental investigation of the effects of alarm processing and display on operator performance

    SciTech Connect

    O`Hara, J.; Brown, W.; Hallbert, B.; Skraaning, G.; Wachtel, J.; Persensky, J.

    1998-03-01

    This paper describes a research program sponsored by the US Nuclear Regulatory Commission to address the human factors engineering (HFE) aspects of nuclear power plant alarm systems. The overall objective of the program is to develop HFE review guidance for advanced alarm systems. As part of this program, guidance has been developed based on a broad base of technical and research literature. In the course of guidance development, aspects of alarm system design for which the technical basis was insufficient to support complete guidance development were identified. The primary purpose of the research reported in this paper was to evaluate the effects of three of these alarm system design characteristics on operator performance in order to contribute to the understanding of potential safety issues and to provide data to support the development of design review guidance in these areas. Three alarm system design characteristics studied were (1) alarm processing (degree of alarm reduction), (2) alarm availability (dynamic prioritization and suppression), and (3) alarm display (a dedicated tile format, a mixed tile and message list format, and a format in which alarm information is integrated into the process displays). A secondary purpose was to provide confirmatory evidence of selected alarm system guidance developed in an earlier phase of the project. The alarm characteristics were combined into eight separate experimental conditions. Six, two-person crews of professional nuclear power plant operators participated in the study. Following training, each crew completed 16 test trials which consisted of two trials in each of the eight experimental conditions (one with a low-complexity scenario and one with a high-complexity scenario). Measures of process performance, operator task performance, situation awareness, and workload were obtained. In addition, operator opinions and evaluations of the alarm processing and display conditions were collected. No deficient

  15. Criticality accident alarm system at the Fernald Environmental Management Project

    SciTech Connect

    Marble, R.C.; Brown, T.D.; Wooldridge, J.C.

    1994-12-31

    This paper describes the staus of the Fernald Environmental Management Project (FEMP) criticality alarm system. A new radiation detection alarm system was installed in 1990. The anunciation system, calibration and maintenance, and detector placement is described.

  16. Cost-Effective School Alarm Systems. Security Topics Series.

    ERIC Educational Resources Information Center

    Kaufer, Steve

    This document outlines considerations in the selection of a cost-effective school-alarm system. Steps in the planning process include: conducting a district needs assessment; gathering input from all staff levels; consulting technical expertise; and selecting a security system that can be integrated with other site needs. It further describes the…

  17. 46 CFR 183.550 - General alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) ELECTRICAL INSTALLATION Miscellaneous Systems and Requirements § 183.550 General alarm systems. All vessels... required by § 184.610 of this chapter may be used to sound the general alarm signal....

  18. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Manual fire alarm systems. 161.002-12 Section 161.002-12...: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-12 Manual fire alarm systems. (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which...

  19. 46 CFR 161.002-12 - Manual fire alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Manual fire alarm systems. 161.002-12 Section 161.002-12...: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-12 Manual fire alarm systems. (a) General. A manual fire alarm system shall consist of a power supply, a control unit on which...

  20. Nuclear-power-plant perimeter-intrusion alarm systems

    SciTech Connect

    Halsey, D.J.

    1982-04-01

    Timely intercept of an intruder requires the examination of perimeter barriers and sensors in terms of reliable detection, immediate assessment and prompt response provisions. Perimeter security equipment and operations must at the same time meet the requirements of the Code of Federal Regulations, 10 CFR 73.55 with some attention to the performance and testing figures of Nuclear Regulatory Guide 5.44, Revision 2, May 1980. A baseline system is defined which recommends a general approach to implementing perimeter security elements: barriers, lighting, intrusion detection, alarm assessment. The baseline approach emphasizes cost/effectiveness achieved by detector layering and logic processing of alarm signals to produce reliable alarms and low nuisance alarm rates. A cost benefit of layering along with video assessment is reduction in operating expense. The concept of layering is also shown to minimize testing costs where detectability performance as suggested by Regulatory Guide 5.44 is to be performed. Synthesis of the perimeter intrusion alarm system and limited testing of CCTV and Video Motion Detectors (VMD), were performed at E-Systems, Greenville Division, Greenville, Texas during 1981.

  1. 46 CFR 76.05-5 - Manual alarm system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Manual alarm system. 76.05-5 Section 76.05-5 Shipping... Fire Detecting and Extinguishing Equipment, Where Required § 76.05-5 Manual alarm system. (a) An approved manual alarm system shall be installed in all areas, other than the main machinery spaces,...

  2. 33 CFR 127.201 - Sensing and alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Equipment § 127.201 Sensing and alarm systems. (a) Fixed sensors must have audio and visual alarms in the control room and audio alarms...

  3. Human factors engineering guidance for the review of advanced alarm systems

    SciTech Connect

    O`Hara, J.M.; Brown, W.S.; Higgins, J.C.; Stubler, W.F.

    1994-09-01

    This report provides guidance to support the review of the human factors aspects of advanced alarm system designs in nuclear power plants. The report is organized into three major sections. The first section describes the methodology and criteria that were used to develop the design review guidelines. Also included is a description of the scope, organization, and format of the guidelines. The second section provides a systematic review procedure in which important characteristics of the alarm system are identified, described, and evaluated. The third section provides the detailed review guidelines. The review guidelines are organized according to important characteristics of the alarm system including: alarm definition; alarm processing and reduction; alarm prioritization and availability; display; control; automated; dynamic, and modifiable characteristics; reliability, test, maintenance, and failure indication; alarm response procedures; and control-display integration and layout.

  4. Development of net cage acoustic alarm system

    NASA Astrophysics Data System (ADS)

    Hong, Shih-Wei; Wei, Ruey-Chang

    2001-05-01

    In recent years, the fishery production has been drastically decreased in Taiwan, mainly due to overfishing and coast pollution; therefore, fishermen and corporations are encouraged by government to invest in ocean net cage aquaculture. However, the high-price fishes in the net cage are often coveted, so incidences of fish stealing and net cage breaking were found occasionally, which cause great economical loss. Security guards or a visual monitoring system has limited effect, especially in the night when these intrusions occur. This study is based on acoustic measure to build a net cage alarm system, which includes the sonobuoy and monitor station on land. The sonobuoy is a passive sonar that collects the sounds near the net cage and transmits the suspected signal to the monitor station. The signals are analyzed by the control program on the personal computer in the monitor station, and the alarms at different stages could be activated by the sound levels and durations of the analyzed data. To insure long hours of surveillance, a solar panel is applied to charge the battery, and a photodetector is used to activate the system.

  5. A revival of the alarm system: Making the alarm list useful during incidents

    SciTech Connect

    Larsson, J. E.; Oehman, B.; Calzada, A.; Nihlwing, C.; Jokstad, H.; Kristianssen, L. I.; Kvalem, J.; Lind, M.

    2006-07-01

    In control rooms there are often problems with information overload, which means that the operators may receive more information than they are able to interpret. The most serious information overload occurs in two types of situations. The first is when the operating state of the plant changes, which often gives raise to a shower of alarms and events. Such an alarm shower is expected, but can be dangerous, because it may hide other alarms originating from unrelated faults. The second problem occurs when a fault causes several consequential faults, leading to a so-called alarm cascade. Because the alarms seldom arrive in correct time order, it can be very difficult to analyze such a cascade, and the information overload occurs in exactly the moment when a potentially dangerous situation starts. In an ongoing project, GoalArt and IFE are cooperating in testing and evaluating GoalArt's methods for alarm reduction and root cause analysis. The testing comprises two specific algorithms, root cause analysis and state-based alarm priority. The GoalArt system has been integrated with the HAMBO simulator so that operators can evaluate the algorithms on-line. (authors)

  6. Recent Results on "Approximations to Optimal Alarm Systems for Anomaly Detection"

    NASA Technical Reports Server (NTRS)

    Martin, Rodney Alexander

    2009-01-01

    An optimal alarm system and its approximations may use Kalman filtering for univariate linear dynamic systems driven by Gaussian noise to provide a layer of predictive capability. Predicted Kalman filter future process values and a fixed critical threshold can be used to construct a candidate level-crossing event over a predetermined prediction window. An optimal alarm system can be designed to elicit the fewest false alarms for a fixed detection probability in this particular scenario.

  7. SCADA alarms processing for wind turbine component failure detection

    NASA Astrophysics Data System (ADS)

    Gonzalez, E.; Reder, M.; Melero, J. J.

    2016-09-01

    Wind turbine failure and downtime can often compromise the profitability of a wind farm due to their high impact on the operation and maintenance (O&M) costs. Early detection of failures can facilitate the changeover from corrective maintenance towards a predictive approach. This paper presents a cost-effective methodology to combine various alarm analysis techniques, using data from the Supervisory Control and Data Acquisition (SCADA) system, in order to detect component failures. The approach categorises the alarms according to a reviewed taxonomy, turning overwhelming data into valuable information to assess component status. Then, different alarms analysis techniques are applied for two purposes: the evaluation of the SCADA alarm system capability to detect failures, and the investigation of the relation between components faults being followed by failure occurrences in others. Various case studies are presented and discussed. The study highlights the relationship between faulty behaviour in different components and between failures and adverse environmental conditions.

  8. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... alarm signaling systems used for alerting employees regardless of the other functions of the system. (3... 29 Labor 5 2011-07-01 2011-07-01 false Employee alarm systems. 1910.165 Section 1910.165 Labor... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Fire Protection Other Fire Protection Systems § 1910.165...

  9. Alarm handler for the advanced photon source control system

    SciTech Connect

    Kraimer, M.R.; Cha, B.K.; Anderson, M.

    1991-01-01

    The Advanced Photon Source (APS), now under construction at Argonne National Laboratory, will have a control system employing graphics workstations at the operator interface level and VME-based microprocessors operating with a distributed database at the field level. The alarm handler is an application utilizing X-Windows running on one or more operator interface workstations which monitors alarms generated by the VME-based microprocessors. Alarms can be grouped in a hierarchical manner. The operator can monitor, acknowledge, and mask alarms either individually or aggregately. Alarm changes of state and all operator modifications are logged. When alarms occur, display windows are automatically generated conveying system and subsystem relationships and severity. Menus are used to modify the alarm action configuration files and to obtain help. Since alarm groups are defined via an alarm configuration file, the alarm handler is a general purpose application which can be customized to monitor a single subsystem or configured to monitor the entire accelerator complex. 2 refs., 2 figs.

  10. 46 CFR 154.1842 - Cargo system: Controls and alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Cargo system: Controls and alarms. 154.1842 Section 154.1842 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... system: Controls and alarms. The master shall ensure that the cargo emergency shut-down system and...

  11. 46 CFR 154.1842 - Cargo system: Controls and alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo system: Controls and alarms. 154.1842 Section 154... SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1842 Cargo system: Controls and alarms. The master shall ensure that the cargo emergency shut-down system and...

  12. 46 CFR 183.550 - General alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false General alarm systems. 183.550 Section 183.550 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) ELECTRICAL INSTALLATION Miscellaneous Systems and Requirements § 183.550 General alarm systems. All...

  13. Masters Thesis- Criticality Alarm System Design Guide with Accompanying Alarm System Development for the Radioisotope Production Laboratory in Richland, Washington

    SciTech Connect

    Greenfield, Bryce A.

    2009-12-01

    A detailed instructional manual was created to guide criticality safety engineers through the process of designing a criticality alarm system (CAS) for Department of Energy (DOE) hazard class 1 and 2 facilities. Regulatory and technical requirements were both addressed. A list of design tasks and technical subtasks are thoroughly analyzed to provide concise direction for how to complete the analysis. An example of the application of the design methodology, the Criticality Alarm System developed for the Radioisotope Production Laboratory (RPL) of Richland, Washington is also included. The analysis for RPL utilizes the Monte Carlo code MCNP5 for establishing detector coverage in the facility. Significant improvements to the existing CAS were made that increase the reliability, transparency, and coverage of the system.

  14. Pressurized security barrier and alarm system

    DOEpatents

    Carver, Don W.

    1995-01-01

    A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder's making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed.

  15. Pressurized security barrier and alarm system

    DOEpatents

    Carver, D.W.

    1995-04-11

    A security barrier for placement across a passageway is made up of interconnected pressurized tubing made up in a grid pattern with openings too small to allow passage. The tubing is connected to a pressure switch, located away from the barrier site, which activates an alarm upon occurrence of a pressure drop. A reinforcing bar is located inside and along the length of the tubing so as to cause the tubing to rupture and set off the alarm upon an intruder`s making an attempt to crimp and seal off a portion of the tubing by application of a hydraulic tool. Radial and rectangular grid patterns are disclosed. 7 figures.

  16. The calibration and the monitoring/alarm system

    NASA Astrophysics Data System (ADS)

    Cappella, F.; Caracciolo, V.; Cerulli, R.; Bussolotti, A.; Mattei, A.

    2016-10-01

    Two important parts of the DAMA/LIBRA setup are the calibration system and the monitoring/alarm system. The calibration system allows to perform detector calibrations without changing the running condition of the experiment; the monitoring/alarm system allows to record several parameters to control the running status and its stability. In this paper, we will describe the two system reporting some related obtained results.

  17. Research on the fire alarming system of fiber grating

    NASA Astrophysics Data System (ADS)

    Qi, Yaobin

    2007-09-01

    The application of fiber grating sensing technology in fire alarming based on temperature detection has the advantages of high accuracy, high reliability and strong immunity from electronic and magnetic fields. It is especially advantageous to use this system in the petroleum and chemistry industry because it can provide an extraordinary safe means for the fire alarm. But due to the traditional optical Wavelength Division Multiplexing (WDM) technology is limited by the optic source bandwidth, the number of its multiplexing points is few. In this paper WDM technology will be developed mixing with Identified Bragg, which is called Identified and Wavelength Multiplexing, to build the Fiber Grating (FBG) fire alarm system integrated with computers. Some technologies applied in fire alarming system of fiber grating such as the transmission of test signals which pass through modulate and demodulate, the disposal of software system, the output of control signal and the strong ability of anti-disturbance have been studied and discussed.

  18. 18. DETAIL VIEW OF FIRE ALARM SYSTEM BOARD THAT LISTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. DETAIL VIEW OF FIRE ALARM SYSTEM BOARD THAT LISTS AREAS IN SHOPS COMPLEX. - Baltimore & Ohio Railroad, Mount Clare Shops, South side of Pratt Street between Carey & Poppleton Streets, Baltimore, Independent City, MD

  19. 29 CFR 1910.165 - Employee alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emergency action plan, or for reaction time for safe escape of employees from the workplace or the immediate... light levels by all employees in the affected portions of the workplace. Tactile devices may be used to... communication system also serves as the employee alarm system, all emergency messages shall have priority...

  20. Advanced Alarm Systems: Revision of Guidance and Its Technical Basis

    DTIC Science & Technology

    2000-11-01

    bulletins and information notices; inspection and investigative reports; licensee event reports; and Commission papers and their attachments. NRC...List System CANDU Canadian Deuterium Uranium CE Combustion Engineering CPIAS Critical Parameter Indication and Alarm System CRT cathode ray tube...strategy for CANDU plants, Davey et al., (1995) noted that warning of conditions potentially leading to upsets is enhanced by including rate and margin

  1. Integrated alarm annunciation and entry control systems -- Survey results

    SciTech Connect

    Clever, J.J.; Arakaki, L.H.; Monaco, F.M.; Juarros, L.E.; Quintana, G.R.

    1993-10-01

    This report provides the results and analyses of a detailed survey undertaken in Summer 1993 to address integrated intrusion detection alarm annunciation and entry control system issues. This survey was undertaken as a first attempt toward beginning to answer questions about integrated systems and commercial capabilities to meet or partially meet US Department of Energy (DOE) site needs.

  2. Specification of business rules for the development of hospital alarm system: application to the pharmaceutical validation.

    PubMed

    Boussadi, Abdelali; Bousquet, Cedric; Sabatier, Brigitte; Colombet, Isabelle; Degoulet, Patrice

    2008-01-01

    Although clinical alarm systems are part of the knowledge management setting within healthcare organisations, modelling of business processes related to decision support and knowledge representation of decision rules are seldom described. We propose a customization of the Unified Process that takes into account user requirements for clinical alarm systems by introducing the Semantics of Business Vocabulary and Business Rules (SBVR). This methodology was applied to the design and implementation of a clinical alarm system for pharmaceutical validation at the European Hospital Georges Pompidou (HEGP). Rules were implemented using the IlogJRules Business Rule Management System. We produced 3 business rules patterns and 427 instances of rules. As SBVR is close to natural language, pharmacists were able to understand rules and participate to their design.

  3. Impact of drum storage on criticality accident alarm systems

    SciTech Connect

    Finfrock, S.; Watson, T.; Byrd, J.; Miles, B.; Wilkinson, A.

    1997-12-01

    The changing mission from production to decommissioning that is taking place at many U.S. Department of Energy sites is producing an ever-increasing inventory of waste drums. These drums typically contain low-level radioactive waste and, in some cases, significant amounts of fissile materials. Such drums must be handled with all of the care necessary for radioactive materials and, where fissile materials are present, criticality safety controls. As the number of drums increases, the question inevitably arises as to where to store them. Old process buildings present one solution to that question. These buildings are typically large, designed to handle radioactive and fissile materials, and largely unused under the current mission and, as such, would seem ideal candidates for at least short-term storage of waste drums. When undergoing such a major change in mission, however, the building`s nuclear safety systems need to be reevaluated to ensure that they are appropriate for the new activity. One such system that must be evaluated is the building`s criticality accident alarm system (AAS). This system is designed to detect criticality accidents and is generally required anywhere that a criticality accident is credible. If drums are to be stored in a facility where a CAAS is required (either because of other activities in the building or because of the contents of the drums themselves), then those drums must be shown not to prevent the CAAS from functioning as designed.

  4. Reducing SCADA System Nuisance Alarms in the Water Industry in Northern Ireland.

    PubMed

    O'Donoghue, Nigel; Phillips, Debra H; Nicell, Ciaran

    2015-08-01

    The advancement of telemetry control for the water industry has increased the difficulty of managing large volumes of nuisance alarms (i.e., alarms that do not require a response). The aim of this study was to identify and reduce the number of nuisance alarms that occur for Northern Ireland (NI) Water by carrying out alarm duration analysis to determine the appropriate length of persistence (an advanced alarm management tool) that could be applied. All data were extracted from TelemWeb (NI Water's telemetry monitoring system) and analyzed in Excel. Over a 6-week period, an average of 40 000 alarms occurred per week. The alarm duration analysis, which has never been implemented before by NI Water, found that an average of 57% of NI Water alarms had a duration of <5 minutes. Applying 5-minute persistence, therefore, could prevent an average 26 816 nuisance alarms per week. Most of these alarms were from wastewater assets.

  5. How Distinctive Processing Enhances Hits and Reduces False Alarms

    PubMed Central

    Hunt, R. Reed; Smith, Rebekah E.

    2015-01-01

    Distinctive processing is a concept designed to account for precision in memory, both correct responses and avoidance of errors. The principal question addressed in two experiments is how distinctive processing of studied material reduces false alarms to familiar distractors. Jacoby (Jacoby, Kelley, & McElree, 1999) has used the metaphors early selection and late correction to describe two different types of control processes. Early selection refers to limitations on access whereas late correction describes controlled monitoring of accessed information. The two types of processes are not mutually exclusive, and previous research has provided evidence for the operation of both. The data reported here extend previous work to a criterial recollection paradigm and to a recognition memory test. The results of both experiments show that variables that reduce false memory for highly familiar distracters continue to exert their effect under conditions of minimal post-access monitoring. Level of monitoring was reduced in the first experiment through test instructions and in the second experiment through speeded test responding. The results were consistent with the conclusion that both early selection and late correction operate to control accuracy in memory. PMID:26034343

  6. 46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under § 154.1330, each cargo tank must have a high liquid level alarm system that: (a) Is independent of...

  7. 46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under § 154.1330, each cargo tank must have a high liquid level alarm system that: (a) Is independent of...

  8. 46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under § 154.1330, each cargo tank must have a high liquid level alarm system that: (a) Is independent of...

  9. 46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Liquid level alarm system: All cargo tanks. 154.1325... Equipment Instrumentation § 154.1325 Liquid level alarm system: All cargo tanks. Except as allowed under § 154.1330, each cargo tank must have a high liquid level alarm system that: (a) Is independent of...

  10. 33 CFR 149.414 - What are the requirements for a fire detection and alarm system?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fire detection and alarm system? 149.414 Section 149.414 Navigation and Navigable Waters COAST GUARD... requirements for a fire detection and alarm system? (a) All accommodation and service spaces on a manned..., transferring, or regasifying liquefied natural gas, must have an automatic fire detection and alarm system...

  11. 33 CFR 149.414 - What are the requirements for a fire detection and alarm system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... fire detection and alarm system? 149.414 Section 149.414 Navigation and Navigable Waters COAST GUARD... requirements for a fire detection and alarm system? (a) All accommodation and service spaces on a manned..., transferring, or regasifying liquefied natural gas, must have an automatic fire detection and alarm system...

  12. 46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Liquid level alarm system: Independent tank type C. 154..., Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type C. Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if: (a) The...

  13. Orthos, an alarm system for the ALICE DAQ operations

    NASA Astrophysics Data System (ADS)

    Chapeland, Sylvain; Carena, Franco; Carena, Wisla; Chibante Barroso, Vasco; Costa, Filippo; Denes, Ervin; Divia, Roberto; Fuchs, Ulrich; Grigore, Alexandru; Simonetti, Giuseppe; Soos, Csaba; Telesca, Adriana; Vande Vyvre, Pierre; von Haller, Barthelemy

    2012-12-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector studying the physics of strongly interacting matter and the quark-gluon plasma at the CERN LHC (Large Hadron Collider). The DAQ (Data Acquisition System) facilities handle the data flow from the detectors electronics up to the mass storage. The DAQ system is based on a large farm of commodity hardware consisting of more than 600 devices (Linux PCs, storage, network switches), and controls hundreds of distributed hardware and software components interacting together. This paper presents Orthos, the alarm system used to detect, log, report, and follow-up abnormal situations on the DAQ machines at the experimental area. The main objective of this package is to integrate alarm detection and notification mechanisms with a full-featured issues tracker, in order to prioritize, assign, and fix system failures optimally. This tool relies on a database repository with a logic engine, SQL interfaces to inject or query metrics, and dynamic web pages for user interaction. We describe the system architecture, the technologies used for the implementation, and the integration with existing monitoring tools.

  14. 40 CFR 264.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operation must have immediate access to an internal alarm or emergency communication device, either directly... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Access to communications or alarm... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a)...

  15. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm,...

  16. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm,...

  17. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm,...

  18. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm,...

  19. 33 CFR 149.135 - What should be marked on the cargo transfer system alarm switch?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false What should be marked on the cargo transfer system alarm switch? 149.135 Section 149.135 Navigation and Navigable Waters COAST GUARD... switch? Each switch for activating an alarm, and each audio or visual device for signaling an alarm,...

  20. Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Greensburg, Paul; McKnight, Robert; Xu, Jennifer C.; Liu, C. C.; Dutta, Prabir; Makel, Darby; Blake, D.; Sue-Antillio, Jill

    2007-01-01

    Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can

  1. The Effects of Alarm Display, Processing, and Availability on Crew Performance

    DTIC Science & Technology

    2000-11-01

    memoranda; bulletins and information notices; inspection and investigative reports; licensee event reports; and Commission papers and their...Halden, Norway: OECD Halden Reactor Project. Moore, R., Popovic, J., and Pauksens, J. (1993). Alarm annunciation in CANDU 3 control room design. In...A-A NUREG/CR-6691 BNL-NUREG-52600 The Effects of Alarm Display, Processing, and Availability on Crew Performance I Brookhaven National

  2. 46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned...

  3. 46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned...

  4. 46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned...

  5. 46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned...

  6. 46 CFR 113.25-25 - General emergency alarm systems for manned ocean and coastwise barges.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false General emergency alarm systems for manned ocean and coastwise barges. 113.25-25 Section 113.25-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Systems § 113.25-25 General emergency alarm systems for manned ocean and coastwise barges. A manned...

  7. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.-TB/ALL. 31.35-5 Section 31.35-5 Shipping COAST GUARD, DEPARTMENT... Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.—TB/ALL. All...

  8. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.-TB/ALL. 31.35-5 Section 31.35-5 Shipping COAST GUARD, DEPARTMENT... Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.—TB/ALL. All...

  9. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.-TB/ALL. 31.35-5 Section 31.35-5 Shipping COAST GUARD, DEPARTMENT... Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.—TB/ALL. All...

  10. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.-TB/ALL. 31.35-5 Section 31.35-5 Shipping COAST GUARD, DEPARTMENT... Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.—TB/ALL. All...

  11. 46 CFR 31.35-5 - Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.-TB/ALL. 31.35-5 Section 31.35-5 Shipping COAST GUARD, DEPARTMENT... Communications; alarm systems, telephone and voice tube systems, engine telegraph systems, etc.—TB/ALL. All...

  12. A Human Factors Perspective on Alarm System Research and Development 2000 to 2010

    SciTech Connect

    Curt Braun; John Grimes; Eric Shaver; Ronald Boring

    2011-09-01

    By definition, alarms serve to notify human operators of out-of-parameter conditions that could threaten equipment, the environment, product quality and, of course, human life. Given the complexities of industrial systems, human machine interfaces, and the human operator, the understanding of how alarms and humans can best work together to prevent disaster is continually developing. This review examines advances in alarm research and development from 2000 to 2010 and includes the writings of trade professionals, engineering and human factors researchers, and standards organizations with the goal of documenting advances in alarms system design, research, and implementation.

  13. The research of highway traffic accident management and pre-alarm system

    NASA Astrophysics Data System (ADS)

    Xu, Jianping; Zhang, Tiejun; Wan, Jiaonan; Zhang, Juwen; Wang, Rui

    For the rigorous traffic safety issues resulting from rapid transportation development, as well as the more and more attention paid to the traffic accidents dynamic analysis and pre-alarm methods, combined with the practical needs of the highway safety management, this paper summarizes the experience of traffic safety pre-alarm research both in domestic and abroad, designs the frame of highway traffic accident management and pre-alarm system from the function and software engineering requirement, and refines kernel modules such as accident prone section judgement, traffic safety pre-alarm analysis and perfecting safety measures analysis, in order to guide the exploitation and application of the system.

  14. Plutonium Finishing Plant (PFP) Criticality Alarm System Commercial Grade Item (CGI) Critical Characteristics

    SciTech Connect

    WHITE, W.F.

    1999-09-16

    This document specifies the critical characteristics for Commercial Grade Items (CGI) procured for PFP's criticality alarm system as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item. PFP's Criticality Alarm System includes the nine criticality alarm system panels and their associated hardware. This includes all parts up to the first breaker in the electrical distribution system. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-003, ''Definition and Means of Maintaining the Criticality Detectors and Alarms Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.''

  15. Development and evaluation of new coupling system for lower limb prostheses with acoustic alarm system.

    PubMed

    Eshraghi, Arezoo; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ahmadian, Jalil; Rahmati, Bizhan; Abas, Wan Abu Bakar Wan

    2013-01-01

    Individuals with lower limb amputation need a secure suspension system for their prosthetic devices. A new coupling system was developed that is capable of suspending the prosthesis. The system's safety is ensured through an acoustic alarm system. This article explains how the system works and provides an in vivo evaluation of the device with regard to pistoning during walking. The system was designed to be used with silicone liners and is based on the requirements of prosthetic suspension systems. Mechanical testing was performed using a universal testing machine. The pistoning during walking was measured using a motion analysis system. The new coupling device produced significantly less pistoning compared to a common suspension system (pin/lock). The safety alarm system would buzz if the suspension was going to fail. The new coupling system could securely suspend the prostheses in transtibial amputees and produced less vertical movement than the pin/lock system.

  16. SILENE Benchmark Critical Experiments for Criticality Accident Alarm Systems

    SciTech Connect

    Miller, Thomas Martin; Reynolds, Kevin H.

    2011-01-01

    In October 2010 a series of benchmark experiments was conducted at the Commissariat a Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE [1] facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems (CAASs). This presentation will discuss the geometric configuration of these experiments and the quantities that were measured and will present some preliminary comparisons between the measured data and calculations. This series consisted of three single-pulsed experiments with the SILENE reactor. During the first experiment the reactor was bare (unshielded), but during the second and third experiments it was shielded by lead and polyethylene, respectively. During each experiment several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor, and some of these detectors were themselves shielded from the reactor by high-density magnetite and barite concrete, standard concrete, and/or BoroBond. All the concrete was provided by CEA Saclay, and the BoroBond was provided by Y-12 National Security Complex. Figure 1 is a picture of the SILENE reactor cell configured for pulse 1. Also included in these experiments were measurements of the neutron and photon spectra with two BICRON BC-501A liquid scintillators. These two detectors were provided and operated by CEA Valduc. They were set up just outside the SILENE reactor cell with additional lead shielding to prevent the detectors from being saturated. The final detectors involved in the experiments were two different types of CAAS detectors. The Babcock International Group provided three CIDAS CAAS detectors, which measured photon dose and dose rate with a Geiger-Mueller tube. CIDAS detectors are currently in

  17. 40 CFR 264.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a) Whenever... that such a device is not required under § 264.32. (b) If there is ever just one employee on...

  18. 40 CFR 264.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a) Whenever... that such a device is not required under § 264.32. (b) If there is ever just one employee on...

  19. 40 CFR 264.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a) Whenever... that such a device is not required under § 264.32. (b) If there is ever just one employee on...

  20. 40 CFR 264.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... FACILITIES Preparedness and Prevention § 264.34 Access to communications or alarm system. (a) Whenever... that such a device is not required under § 264.32. (b) If there is ever just one employee on...

  1. 46 CFR 154.1330 - Liquid level alarm system: Independent tank type C.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Instrumentation § 154.1330 Liquid level alarm system: Independent tank type...

  2. 40 CFR 267.34 - When must personnel have access to communication equipment or an alarm system?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... to an internal alarm or emergency communication device, either directly or through visual or voice... communication equipment or an alarm system? 267.34 Section 267.34 Protection of Environment ENVIRONMENTAL... have access to communication equipment or an alarm system? (a) Whenever hazardous waste is being...

  3. Earthquake alarm system for the Maui-A offshore platform, New Zealand

    SciTech Connect

    Tyler, R.G.; Beck, J.L.

    1983-02-01

    Situated in the Tasman Sea, the Maui A offshore gas production platform has an earthquake alarm system that gives immediate warning when the seismic accelerations reach half the platform's design level. The system monitors only the response of the lower modes of the platform, as these make the major contribution to the stresses in the structure. In order to reduce the risk of false alarms, a radio link with similar detectors on shore confirms that an earthquake has occurred.

  4. Cooperative warning systems: The impact of false and unnecessary alarms on drivers' compliance.

    PubMed

    Naujoks, Frederik; Kiesel, Andrea; Neukum, Alexandra

    2016-12-01

    Cooperative warning systems have a great potential to prevent traffic accidents. However, because of their predictive nature, they might also go along with an increased frequency of incorrect alarms that could limit their effectiveness. To better understand the consequences associated with incorrect alarms, a driving simulator study with N=80 drivers was conducted to investigate how situational context and warning urgency jointly influence drivers' compliance with an unreliable advisory warning system (AWS). The participants encountered several critical urban driving situations and were either assisted by a 100% reliable AWS, a 60% reliable AWS that generated false alarms (without obvious reason) or a 60% reliable AWS that generated unnecessary alarms (with plausible reason). A baseline drive without any assistance was also introduced to the study. The warnings were presented either only visually or visual-auditory. In line with previous research, drivers' compliance and effectiveness of the AWS was reduced by false alarms but not by unnecessary alarms. However, this so-called cry wolf effect (Breznitz, 1984) was only found in the visual-auditory condition, whereas there was no effect of warning reliability in the condition with visual AWS. Furthermore, false but not unnecessary alarms caused the participants to rate the AWS less favourably during a follow-up interview. In spite of these negative effects of false alarms, a reduction in the frequency of safety-critical events (SCEs) and an earlier braking onset were evident in all assisted drives compared with that of non-assisted driving, even when the AWS was unreliable. The results may thus lower concerns about the negative consequences of warning drivers unnecessarily about upcoming traffic conflicts if the reasons of these alarms are comprehensible. From a perspective of designing AWS, we recommend to use less urgent warnings to prevent the cry wolf effect.

  5. Low Power Wireless Smoke Alarm System in Home Fires.

    PubMed

    Aponte Luis, Juan; Gómez Galán, Juan Antonio; Alcina Espigado, Javier

    2015-08-21

    A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects.

  6. Low Power Wireless Smoke Alarm System in Home Fires

    PubMed Central

    Luis, Juan Aponte; Galán, Juan Antonio Gómez; Espigado, Javier Alcina

    2015-01-01

    A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects. PMID:26307994

  7. Estimating Alarm Thresholds for Process Monitoring Data under Different Assumptions about the Data Generating Mechanism

    DOE PAGES

    Burr, Tom; Hamada, Michael S.; Howell, John; ...

    2013-01-01

    Process monitoring (PM) for nuclear safeguards sometimes requires estimation of thresholds corresponding to small false alarm rates. Threshold estimation dates to the 1920s with the Shewhart control chart; however, because possible new roles for PM are being evaluated in nuclear safeguards, it is timely to consider modern model selection options in the context of threshold estimation. One of the possible new PM roles involves PM residuals, where a residual is defined as residual = data − prediction. This paper reviews alarm threshold estimation, introduces model selection options, and considers a range of assumptions regarding the data-generating mechanism for PM residuals.more » Two PM examples from nuclear safeguards are included to motivate the need for alarm threshold estimation. The first example involves mixtures of probability distributions that arise in solution monitoring, which is a common type of PM. The second example involves periodic partial cleanout of in-process inventory, leading to challenging structure in the time series of PM residuals.« less

  8. Alarm systems detect volcanic tremor and earthquake swarms during Redoubt eruption, 2009

    NASA Astrophysics Data System (ADS)

    Thompson, G.; West, M. E.

    2009-12-01

    We ran two alarm algorithms on real-time data from Redoubt volcano during the 2009 crisis. The first algorithm was designed to detect escalations in continuous seismicity (tremor). This is implemented within an application called IceWeb which computes reduced displacement, and produces plots of reduced displacement and spectrograms linked to the Alaska Volcano Observatory internal webpage every 10 minutes. Reduced displacement is a measure of the amplitude of volcanic tremor, and is computed by applying a geometrical spreading correction to a displacement seismogram. When the reduced displacement at multiple stations exceeds pre-defined thresholds and there has been a factor of 3 increase in reduced displacement over the previous hour, a tremor alarm is declared. The second algorithm was to designed to detect earthquake swarms. The mean and median event rates are computed every 5 minutes based on the last hour of data from a real-time event catalog. By comparing these with thresholds, three swarm alarm conditions can be declared: a new swarm, an escalation in a swarm, and the end of a swarm. The end of swarm alarm is important as it may mark a transition from swarm to continuous tremor. Alarms from both systems were dispatched using a generic alarm management system which implements a call-down list, allowing observatory scientists to be called in sequence until someone acknowledged the alarm via a confirmation web page. The results of this simple approach are encouraging. The tremor alarm algorithm detected 26 of the 27 explosive eruptions that occurred from 23 March - 4 April. The swarm alarm algorithm detected all five of the main volcanic earthquake swarm episodes which occurred during the Redoubt crisis on 26-27 February, 21-23 March, 26 March, 2-4 April and 3-7 May. The end-of-swarm alarms on 23 March and 4 April were particularly helpful as they were caused by transitions from swarm to tremor shortly preceding explosive eruptions; transitions which were

  9. A design methodology for effective application of pan-tilt cameras in alarm assessment systems

    SciTech Connect

    Davis, R.F.

    1993-08-01

    Effective application of pan-tilt cameras in alarm assessment systems requires that the overall system design be such that any threat for which the system is designed will be within the field of view of the camera for a sufficiently long time for the assessment of the alarm to be performed. The assessment of alarms in large, unobstructed areas requires a different type of analysis than traditionally used for clear zones between fences along fixed perimeters where an intruder`s possible location is well defined. This paper presents a design methodology which integrates the threat characteristics, sensor detection pattern, system response time, and optics geometry considerations to identify all feasible locations for camera placement for effective assessment of large, unobstructed areas. The methodology also can be used to evaluate tradeoffs among these various considerations to improve candidate designs.

  10. Neural Network Target Identification System for False Alarm Reduction

    NASA Technical Reports Server (NTRS)

    Ye, David; Edens, Weston; Lu, Thomas T.; Chao, Tien-Hsin

    2009-01-01

    A multi-stage automated target recognition (ATR) system has been designed to perform computer vision tasks with adequate proficiency in mimicking human vision. The system is able to detect, identify, and track targets of interest. Potential regions of interest (ROIs) are first identified by the detection stage using an Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter combined with a wavelet transform. False positives are then eliminated by the verification stage using feature extraction methods in conjunction with neural networks. Feature extraction transforms the ROIs using filtering and binning algorithms to create feature vectors. A feed forward back propagation neural network (NN) is then trained to classify each feature vector and remove false positives. This paper discusses the test of the system performance and parameter optimizations process which adapts the system to various targets and datasets. The test results show that the system was successful in substantially reducing the false positive rate when tested on a sonar image dataset.

  11. Design of a Monocular Multi-Spectral Skin Detection, Melanin Estimation, and False-Alarm Suppression System

    DTIC Science & Technology

    2010-03-01

    Design of a Monocular Multi-Spectral Skin Detection, Melanin Estimation, and False-Alarm Suppression System THESIS Keith R. Peskosky, Second...Skin Detection, Melanin Estimation, and False-Alarm Suppression System THESIS Presented to the Faculty Department of Electrical and Computer Engineering...alarm reduction, and melanin estimation system is designed targeting search and rescue (SAR) with application to special operations for manhunting and

  12. 10 CFR 34.75 - Records of alarm system and entrance control checks at permanent radiographic installations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.75 Records of alarm system and entrance control checks at permanent...

  13. 10 CFR 34.75 - Records of alarm system and entrance control checks at permanent radiographic installations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.75 Records of alarm system and entrance control checks at permanent...

  14. 10 CFR 34.75 - Records of alarm system and entrance control checks at permanent radiographic installations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.75 Records of alarm system and entrance control checks at permanent...

  15. Medical audible alarms: a review

    PubMed Central

    Edworthy, Judy

    2013-01-01

    Objectives This paper summarizes much of the research that is applicable to the design of auditory alarms in a medical context. It also summarizes research that demonstrates that false alarm rates are unacceptably high, meaning that the proper application of auditory alarm design principles are compromised. Target audience Designers, users, and manufacturers of medical information and monitoring systems that indicate when medical or other parameters are exceeded and that are indicated by an auditory signal or signals. Scope The emergence of alarms as a ‘hot topic’; an outline of the issues and design principles, including IEC 60601-1-8; the high incidence of false alarms and its impact on alarm design and alarm fatigue; approaches to reducing alarm fatigue; alarm philosophy explained; urgency in audible alarms; different classes of sound as alarms; heterogeneity in alarm set design; problems with IEC 60601-1-8 and ways of approaching this design problem. PMID:23100127

  16. ALARM STRATEGY AND COMPLEXITY: PREDICTIONS OF OPERATOR RESPONSE

    SciTech Connect

    Austin Ragsdale; Roger Lew; Brian Dyre; Ronald Boring; David Gertman

    2012-07-01

    Decision support for operators is not new, and much has been written regarding the potential usefulness of digital support systems and alarm filtering strategies. However, determining the appropriate characteristics of decision support tools is difficult, especially when alarms can vary in the manner which diagnostic information is formulated and displayed and when event scenario types are complex and numerous. When first reviewed, the advantages or disadvantages of a particular alarm approach may not be apparent to the designer or analyst. The present research focuses on the review of two particular alarm strategies, binary alarm type (BAT) and likelihood alarm type (LAT), and reviews their influence upon accuracy, bias, and trust for tasks performed at a computer workstation capable of replicating a series of control-room-like alarms. The findings are discussed in terms of the of the performance advantages of likelihood alarm technology and related research as an aid to the alarm design process.

  17. 33 CFR 149.130 - What are the requirements for the cargo transfer system alarm?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the requirements for the cargo transfer system alarm? 149.130 Section 149.130 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION,...

  18. Interior Communications Supervised Alarm and Warning Systems: Validation of Instructional Materials. Fiscal Year 1977, Final Report.

    ERIC Educational Resources Information Center

    Van Kekerix, Donald L.; And Others

    An empirical study was conducted using Navy trainees to evaluate the effectiveness of instructional modules designed to train Interior Communications electricians in the maintenance and repair of alarm and warning systems installed in ships to signal unsafe conditions. These modules, each containing six lessons, were developed to augment or…

  19. 46 CFR 154.1325 - Liquid level alarm system: All cargo tanks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Liquid level alarm system: All cargo tanks. 154.1325 Section 154.1325 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction...

  20. Role of Large Clinical Datasets From Physiologic Monitors in Improving the Safety of Clinical Alarm Systems and Methodological Considerations: A Case From Philips Monitors

    PubMed Central

    Reed, Charles Calhoun; Staggers, Nancy

    2016-01-01

    Background Large datasets of the audit log of modern physiologic monitoring devices have rarely been used for predictive modeling, capturing unsafe practices, or guiding initiatives on alarm systems safety. Objective This paper (1) describes a large clinical dataset using the audit log of the physiologic monitors, (2) discusses benefits and challenges of using the audit log in identifying the most important alarm signals and improving the safety of clinical alarm systems, and (3) provides suggestions for presenting alarm data and improving the audit log of the physiologic monitors. Methods At a 20-bed transplant cardiac intensive care unit, alarm data recorded via the audit log of bedside monitors were retrieved from the server of the central station monitor. Results Benefits of the audit log are many. They include easily retrievable data at no cost, complete alarm records, easy capture of inconsistent and unsafe practices, and easy identification of bedside monitors missed from a unit change of alarm settings adjustments. Challenges in analyzing the audit log are related to the time-consuming processes of data cleaning and analysis, and limited storage and retrieval capabilities of the monitors. Conclusions The audit log is a function of current capabilities of the physiologic monitoring systems, monitor’s configuration, and alarm management practices by clinicians. Despite current challenges in data retrieval and analysis, large digitalized clinical datasets hold great promise in performance, safety, and quality improvement. Vendors, clinicians, researchers, and professional organizations should work closely to identify the most useful format and type of clinical data to expand medical devices’ log capacity. PMID:27694097

  1. 46 CFR 58.25-25 - Indicating and alarm systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear... the pilothouse upon— (1) Failure of the electric power to the control system of any steering gear; (2...) Overload of any motor described by § 58.25-55(c); or (3) Occurrence of a low oil level in any oil...

  2. 46 CFR 58.25-25 - Indicating and alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear... the pilothouse upon— (1) Failure of the electric power to the control system of any steering gear; (2...) Overload of any motor described by § 58.25-55(c); or (3) Occurrence of a low oil level in any oil...

  3. 46 CFR 58.25-25 - Indicating and alarm systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear... the pilothouse upon— (1) Failure of the electric power to the control system of any steering gear; (2...) Overload of any motor described by § 58.25-55(c); or (3) Occurrence of a low oil level in any oil...

  4. 46 CFR 58.25-25 - Indicating and alarm systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear... the pilothouse upon— (1) Failure of the electric power to the control system of any steering gear; (2...) Overload of any motor described by § 58.25-55(c); or (3) Occurrence of a low oil level in any oil...

  5. 46 CFR 58.25-25 - Indicating and alarm systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear... the pilothouse upon— (1) Failure of the electric power to the control system of any steering gear; (2...) Overload of any motor described by § 58.25-55(c); or (3) Occurrence of a low oil level in any oil...

  6. Expert System Constant False Alarm Rate (CFAR) Processor

    DTIC Science & Technology

    2006-09-01

    Processor has been developed on a Sun Sparc Station 4/470 using a commercial-off-the-shelf software development package called G2 by Gensym Corporation...size of the training data set. A prototype expert system CFAR Processor has been presented which applies artificial intelligence to CFAR detection

  7. Smart container UWB sensor system for situational awareness of intrusion alarms

    DOEpatents

    Romero, Carlos E.; Haugen, Peter C.; Zumstein, James M.; Leach, Jr., Richard R.; Vigars, Mark L.

    2013-06-11

    An in-container monitoring sensor system is based on an UWB radar intrusion detector positioned in a container and having a range gate set to the farthest wall of the container from the detector. Multipath reflections within the container make every point on or in the container appear to be at the range gate, allowing intrusion detection anywhere in the container. The system also includes other sensors to provide false alarm discrimination, and may include other sensors to monitor other parameters, e.g. radiation. The sensor system also includes a control subsystem for controlling system operation. Communications and information extraction capability may also be included. A method of detecting intrusion into a container uses UWB radar, and may also include false alarm discrimination. A secure container has an UWB based monitoring system

  8. The Performance of Earthworm Based Earthquake Alarm Reporting System in Taiwan

    NASA Astrophysics Data System (ADS)

    Chen, Ta-Yi; Hsiao, Nai-Chi; Wu, Yih-Min

    2016-04-01

    The Central Weather Bureau of Taiwan has operated an earthquake early warning (EEW) system and issued warnings to schools and government agencies since 2014. Because the real-time seismic data streams are integrated by the Earthworm software, some EEW modules were created under the Earthworm platform. The system is named Earthworm Based Earthquake Alarm Reporting (eBEAR) system, which is currently operating. The eBEAR system consists of new Earthworm modules for managing P-wave phase picking, trigger associations, hypocenter locations, magnitude estimations, and alert filtering prior to broadcasting. Here, we outline the methodology and performance of the eBEAR system. The online performance of the eBEAR system indicated that the average reporting times afforded by the system are approximately 15 and 26 s for inland and offshore earthquakes, respectively. Comparing to the earthquake catalog, the difference of the epicenters are less than 10 km for inland earthquakes; the difference of the magnitude are about 0.3. No false alarms generated by the system, but there were three false alarms issued by human. Due to the wrong operations, the EEW information created by off-line test were sent. However, we have learned from it and improved the standard operation procedure in the EEW system.

  9. Dynamic alarm response procedures

    SciTech Connect

    Martin, J.; Gordon, P.; Fitch, K.

    2006-07-01

    The Dynamic Alarm Response Procedure (DARP) system provides a robust, Web-based alternative to existing hard-copy alarm response procedures. This paperless system improves performance by eliminating time wasted looking up paper procedures by number, looking up plant process values and equipment and component status at graphical display or panels, and maintenance of the procedures. Because it is a Web-based system, it is platform independent. DARP's can be served from any Web server that supports CGI scripting, such as Apache{sup R}, IIS{sup R}, TclHTTPD, and others. DARP pages can be viewed in any Web browser that supports Javascript and Scalable Vector Graphics (SVG), such as Netscape{sup R}, Microsoft Internet Explorer{sup R}, Mozilla Firefox{sup R}, Opera{sup R}, and others. (authors)

  10. Silent emergency alarm system for schools and the like

    NASA Technical Reports Server (NTRS)

    Read, W. S.; Roberts, V. W. (Inventor)

    1973-01-01

    An emergency alert system is described. In a school each classroom (or other area) is instrumented with a hidden microphone and receiver tuned to a non-audible frequency. The receivers' outputs are connected to a central display unit in the school's administrative office. Each instructor is provided with a small concealable transmitter which, when hand activated by the instructor upon the occurrance of any emergency, generates a non-audible signal at the receiver's tuned frequency.

  11. [A survey of utilization of urinary alarm systems in nursing homes].

    PubMed

    Ueda, T; Hashimoto, M; Nakazono, N

    1995-06-01

    A questionnaire survey was performed on 63 nursing homes and 1006 care workers in the nursing home, in order to elucidate the actual state of utilization of urinary alarm systems (systems). About 3% of the nursing homes in all of Japan are utilizing the system with 12.5% of all institutionalized elderly having a diaper sensor of those nursing homes with the system, 86% use the system continually. In 51% of the nursing homes, care workers change diapers immediately after sensor alarm is triggered. The reasons for not being able to change the diaper immediately were either care workers had other pressing work, or simultaneous or overlapping sensor alarm calls occurred. The usefulness of the system was recognized for "prevention of decubitus" (66%), "prevention of contact dermatitis from diapers" (82%), "decrease of ammonia smell" (27%), and "discontinuation of diaper" (26%). As for problems associated with the system or factors that increase work load, responses included "sensor does not respond sometimes" (67%), "increased diaper changes" (53%), "increased nurse calls due to urinary urgency" (41%), and "disconnection of the sensor by the patient" (34%). The percentage of care workers who reported an increase in work load was 73%, especially where the ratio of care workers number/institutionalized elderly was low.

  12. Visual display and alarm system for wind tunnel static and dynamic loads

    NASA Technical Reports Server (NTRS)

    Hanly, Richard D.; Fogarty, James T.

    1987-01-01

    A wind tunnel balance monitor and alarm system developed at NASA Ames Research Center will produce several beneficial results. The costs of wind tunnel delays because of inadvertent balance damage and the costs of balance repair or replacement can be greatly reduced or eliminated with better real-time information on the balance static and dynamic loading. The wind tunnel itself will have enhanced utility with the elimination of overly cautious limits on test conditions. The microprocessor-based system features automatic scaling and 16 multicolored LED bargraphs to indicate both static and dynamic components of the signals from eight individual channels. Five individually programmable alarm levels are available with relay closures for internal or external visual and audible warning devices and other functions such as automatic activation of external recording devices, model positioning mechanism, or tunnel shutdown.

  13. Visual display and alarm system for wind tunnel static and dynamic loads

    NASA Technical Reports Server (NTRS)

    Hanly, Richard D.; Fogarty, James T.

    1987-01-01

    A wind tunnel balance monitor and alarm system developed at NASA Ames Research Center will produce several beneficial results. The costs of wind tunnel delays because of inadvertent balance damage and the costs of balance repair or replacement can be greatly reduced or eliminated with better real-time information on the balance static and dynamic loading. The wind tunnel itself will have enhanced utility with the elimination of overly cautious limits on test conditions. The microprocessor-based system features automatic scaling and 16 multicolored LED bargraphs to indicate both static and dynamic components of the signals from eight individual channels. Five individually programmable alarm levels are available with relay closures for internal or external visual and audible warning devices and other functions such as automatic activation of external recording devices, model positioning mechanisms, or tunnel shutdown.

  14. Transformation of ground vibration signal for debris-flow monitoring and detection in alarm systems.

    PubMed

    Abancó, Clàudia; Hürlimann, Marcel; Fritschi, Bruno; Graf, Christoph; Moya, José

    2012-01-01

    Debris flows are fast mass movements formed by a mix of water and solid materials, which occur in steep torrents, and are a source of high risks for human settlements. Geophones are widely used to detect the ground vibration induced by passing debris flows. However, the recording of geophone signals usually requires storing a huge amount of data, which leads to problems in storage capacity and power consumption. This paper presents a method to transform and simplify the signals measured by geophones. The key input parameter is the ground velocity threshold, which removes the seismic noise that is not related to debris flows. A signal conditioner was developed to implement the transformation and the ground velocity threshold was set by electrical resistors. The signal conditioner was installed at various European monitoring sites to test the method. Results show that data amount and power consumption can be greatly reduced without losing much information on the main features of the debris flows. However, the outcome stresses the importance of choosing a ground vibration threshold, which must be accurately calibrated. The transformation is also suitable to detect other rapid mass movements and to distinguish among different processes, which points to a possible implementation in alarm systems.

  15. Transformation of Ground Vibration Signal for Debris-Flow Monitoring and Detection in Alarm Systems

    PubMed Central

    Abancó, Clàudia; Hürlimann, Marcel; Fritschi, Bruno; Graf, Christoph; Moya, José

    2012-01-01

    Debris flows are fast mass movements formed by a mix of water and solid materials, which occur in steep torrents, and are a source of high risks for human settlements. Geophones are widely used to detect the ground vibration induced by passing debris flows. However, the recording of geophone signals usually requires storing a huge amount of data, which leads to problems in storage capacity and power consumption. This paper presents a method to transform and simplify the signals measured by geophones. The key input parameter is the ground velocity threshold, which removes the seismic noise that is not related to debris flows. A signal conditioner was developed to implement the transformation and the ground velocity threshold was set by electrical resistors. The signal conditioner was installed at various European monitoring sites to test the method. Results show that data amount and power consumption can be greatly reduced without losing much information on the main features of the debris flows. However, the outcome stresses the importance of choosing a ground vibration threshold, which must be accurately calibrated. The transformation is also suitable to detect other rapid mass movements and to distinguish among different processes, which points to a possible implementation in alarm systems. PMID:22666064

  16. A new approach to importance sampling for the simulation of false alarms. [in radar systems

    NASA Technical Reports Server (NTRS)

    Lu, D.; Yao, K.

    1987-01-01

    In this paper a modified importance sampling technique for improving the convergence of Importance Sampling is given. By using this approach to estimate low false alarm rates in radar simulations, the number of Monte Carlo runs can be reduced significantly. For one-dimensional exponential, Weibull, and Rayleigh distributions, a uniformly minimum variance unbiased estimator is obtained. For Gaussian distribution the estimator in this approach is uniformly better than that of previously known Importance Sampling approach. For a cell averaging system, by combining this technique and group sampling, the reduction of Monte Carlo runs for a reference cell of 20 and false alarm rate of lE-6 is on the order of 170 as compared to the previously known Importance Sampling approach.

  17. Multi-input/output alarming system for patients with inattention caused by higher cortical function disorder

    PubMed Central

    2013-01-01

    Background To apply advanced methods of communication, sensing, and instrumentation technologies to make a system that can help patients suffering from hemispatial neglect caused by higher cortical function disorder. Method By using several sensors and actuators, the objective was to construct a tailor-made system for each patient. The input part of the system consists of sensors, an interface and transmitters. The output part consists of a receiver, logical arithmetic, an output interface and actuators. The information from the input part is sent to the output part in a wireless manner allowing the mobility of the input and output parts. Results The system and its functionality were realized. Voice alarming and neck muscle stimuli were applied to two patients. We could verify the applicability of the system to remind the patients to put on their wheelchair’s brake and raise its footrest before attempting to stand for transferring to their beds. Conclusion The designed and constructed multi-input/output system can be used effectively to alarm the patients. PMID:24119204

  18. A criticism of ANSI/ANS-8. 3-1986: Criticality accident alarm system

    SciTech Connect

    Malenfant, R.E.

    1991-01-01

    The American National Standard on criticality accident alarm systems has given rise to confusion in interpretation and implementation of the requirements. In addition, some of the standards have recently been incorporated into US Department of Energy (DOE) orders, and others have been paraphrased in the DOE orders. Some of the DOE orders referencing these standards are being incorporated into law by means of the Code of Federal Regulations. As such, the intent of the authors of the standards to recommend a code of good practice is now being codified into law with attendant civil and criminal penalties for failure to comply. It is suggested that ANSI/ANS-8.3-1986, Critically Accident Alarm System, be carefully reviewed to alleviate the confusion that has been experienced in practice, to clarify the minimum accident of concern, to further define the dose (or dose rate) criteria for activation, and to stress the fact that a prime consideration in any safety system is the overall reduction of risk.

  19. Industrial Process Surveillance System

    DOEpatents

    Gross, Kenneth C.; Wegerich, Stephan W; Singer, Ralph M.; Mott, Jack E.

    2001-01-30

    A system and method for monitoring an industrial process and/or industrial data source. The system includes generating time varying data from industrial data sources, processing the data to obtain time correlation of the data, determining the range of data, determining learned states of normal operation and using these states to generate expected values, comparing the expected values to current actual values to identify a current state of the process closest to a learned, normal state; generating a set of modeled data, and processing the modeled data to identify a data pattern and generating an alarm upon detecting a deviation from normalcy.

  20. Performance and design of the debris-flow alarm system in the Alpine Illgraben catchment

    NASA Astrophysics Data System (ADS)

    Graf, C.; Badoux, A.; McArdell, B. W.

    2009-04-01

    We present the design and first analysis of the performance of a warning system from the very active Alpine Illgraben debris-flow catchment and fan area. The catchment (9.5 km2), located in the Canton of Valais, Switzerland, is characterized by frequent and voluminous sediment transport and debris-flow events. The residents in Susten (municipality Leuk), tourists, and other land users, are exposed to a significant hazard. The warning system consists of four modules: community organizational planning (hazard awareness and preparedness), event detection and alerting, geomorphic catchment observation, and applied research to facilitate the development of an early warning system based on weather forecasting. The detection system presently provides automated alert signals near the active channel prior to (5-15 min) the arrival of a debris flow or flash flood at the uppermost used channel crossing. It is intended to provide data to support decision-making for warning and evacuation, especially when unusually large debris flows are expected to leave the channel near populated areas. At three frequently used channel crossings, optical and acoustic alert signals were installed which are activated by the detection system installed further up in the channel. Events are detected if the ground vibration signal and/or the flow depth exceed a predefined threshold value. First-year results of the detection and alert module in comparison with the independent automated debris-flow observation station (operated by the WSL since 2000) are generally favorable. Twenty automated alerts were issued in the first year of operation (2007), which triggered flashing lights and sirens at all major footpaths crossing the channel bed, for three debris flows and 16 flood flows. Only one false alarm occurred. In the second year (2008), nine automated alerts were emitted, for three debris flows and five flood flows. One false alarm was produced. The events help to fill a data base for optimizing the

  1. A case of shotgun injury which occurred while an unconventional home security alarm system was being checked.

    PubMed

    Asirdizer, Mahmut; Yavuz, Mehmet Sunay

    2009-11-20

    Installation of devices involving shotguns is rarely encountered in forensic medicine practice. In this case report, authors aimed to present an unusual and rare case of shotgun injury due to a home security alarm system and its legal assessment. An electrical technician was invited to a summer house to check a home security alarm system installed by another firm which he worked for previously. It was an unconventional home security alarm system attached to a shotgun. The technician was injured with 18 buckshot pellets (no: 4) while checking the system. The host was convicted of a possible intent to cause a life-threatening injury to the technician. We think that this verdict will set a precedent for similar cases.

  2. Three-Alarm System: Revisited to treat Thumb-sucking Habit

    PubMed Central

    Shetty, Manoj; Shetty, N Shridhar; Deoghare, Anushka

    2015-01-01

    ABSTRACT Thumb and digit-sucking habits or non-nutritive sucking are considered to be the most prevalent among oral habits. Most children stop thumb sucking on their own. If the habit continues beyond 3 to 4 years of age, it not only affects the dental occlusion, but the shape of the thumb/digit may be altered as well. This article presents the management of thumb sucking by modified RURS, elbow guard incorporated with revised ‘three-alarm’ system. How to cite this article: Shetty RM, Shetty M, Shetty NS, Deoghare A. Three-Alarm System: Revisited to treat Thumb-sucking Habit. Int J Clin Pediatr Dent 2015;8(1):82-86. PMID:26124588

  3. One-Piece Triboelectric Nanosensor for Self-Triggered Alarm System and Latent Fingerprint Detection.

    PubMed

    Jie, Yang; Zhu, Huarui; Cao, Xia; Zhang, Yue; Wang, Ning; Zhang, Liqun; Wang, Zhong Lin

    2016-11-22

    Tactile sensing is of great importance in developing human-machine interface, remote control, and security systems. Here, a self-triggered alarm system based on the one-piece triboelectric nanosensor (TENS) is reported. By using nitrocellulose (NC) membrane as the triboelectric material, the as-designed TENS can not only sensitively respond to physical contacts in a self-triggered mode but also securely detect the third-level details of latent fingerprint. The self-triggered idea based on the triboelectric nanogenerator is compatible with intelligent interactive interface. Besides, this TENS can be conveniently fabricated and integrated into arrays at a large scale due to its freestanding, simple, and low-cost characteristics. This work presents alternative perspectives for the practical applications of the multifunctionalized TENS.

  4. Adaptive System Identification for Estimating Future Glucose Concentrations and Hypoglycemia Alarms.

    PubMed

    Eren-Oruklu, Meriyan; Cinar, Ali; Rollins, Derrick K; Quinn, Lauretta

    2012-08-01

    Many patients with diabetes experience high variability in glucose concentrations that includes prolonged hyperglycemia or hypoglycemia. Models predicting a subject's future glucose concentrations can be used for preventing such conditions by providing early alarms. This paper presents a time-series model that captures dynamical changes in the glucose metabolism. Adaptive system identification is proposed to estimate model parameters which enable the adaptation of the model to inter-/intra-subject variation and glycemic disturbances. It consists of online parameter identification using the weighted recursive least squares method and a change detection strategy that monitors variation in model parameters. Univariate models developed from a subject's continuous glucose measurements are compared to multivariate models that are enhanced with continuous metabolic, physical activity and lifestyle information from a multi-sensor body monitor. A real life application for the proposed algorithm is demonstrated on early (30 min in advance) hypoglycemia detection.

  5. Alarm pheromone induces stress analgesia via an opioid system in the honeybee.

    PubMed

    Núñez, J; Almeida, L; Balderrama, N; Giurfa, M

    1997-12-31

    Changes of the stinging response threshold of Apis mellifera scutellata were measured on foragers fixed on a holder and stimulated with an electric shock as a noxious stimulus. The threshold of responsiveness to the noxious stimulus increased when bees were previously stimulated with isopentyl acetate, which is a main component of the alarm pheromone of the sting chamber. This effect is antagonised by previous injection of naloxone-hydrochloride (Endo Laboratories Inc.). Results suggest that in the honeybee an endogenous opioid system activated by isopentyl acetate is responsible for modulation of perception for nociceptive stimuli. The resulting stress-induced analgesia in the defender bee would reduce its probability of withdrawal thus increasing its efficiency against enemies.

  6. 40 CFR 265.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... involved in the operation must have immediate access to an internal alarm or emergency communication device... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Access to communications or alarm..., STORAGE, AND DISPOSAL FACILITIES Preparedness and Prevention § 265.34 Access to communications or...

  7. The postman always rings twice: two cases of shotgun deaths associated with an unconventional home security alarm system.

    PubMed

    Asirdizer, Mahmut; Turkmen, Nursel; Akan, Okan; Yavuz, Mehmet Sunay

    2014-06-01

    Injury and death cases caused by booby traps are not common in forensic medicine practice. Besides, installation of booby traps including firearms is generally for suicidal and rarely for homicidal purposes. Although few patents were described about home security alarm system that were created by firearms in the United States, 1 sample of injury with a similar unconventional mechanism of home safety system was reported by Asirdizer and Yavuz in 2009. In the published case report, the story of an electrical technician who was invited to a summer house by the homeowner to check the home security alarm system was reported. In the so-called report, he was stated to be injured by the shotgun attached to the unconventional home security alarm system while checking the system. As a result, the homeowner was convicted of a possible intent to cause a life-threatening injury to the technician.The so-called homeowner and his wife died by the same shotgun attached to the same unconventional home security alarm system 4 years on from the first event. In the present case report, we have aimed to present the findings of the crime scene and the autopsies of these unusual 2 deaths and to discuss individual and legal factors in paving the way for the deaths of 2 people.

  8. 40 CFR 265.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Preparedness and Prevention § 265.34 Access to communications or alarm... required under § 265.32. (b) If there is ever just one employee on the premises while the facility...

  9. 40 CFR 265.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Preparedness and Prevention § 265.34 Access to communications or alarm... required under § 265.32. (b) If there is ever just one employee on the premises while the facility...

  10. 40 CFR 265.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Preparedness and Prevention § 265.34 Access to communications or alarm... required under § 265.32. (b) If there is ever just one employee on the premises while the facility...

  11. 40 CFR 265.34 - Access to communications or alarm system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., STORAGE, AND DISPOSAL FACILITIES Preparedness and Prevention § 265.34 Access to communications or alarm... required under § 265.32. (b) If there is ever just one employee on the premises while the facility...

  12. Analysis of criticality accident alarm system coverage in the X-700, X-705, and X-720 facilities at the Portsmouth Gaseous Diffusion plant

    SciTech Connect

    Skapik, C.W.; Dobelbower, M.C.; Woollard, J.E.

    1995-12-01

    Additional services for the uranium enrichment cascade process, such as maintenance and decontamination operations, are provided by several ancillary facilities at the PORTS site. These facilities include the X-700 Maintenance Facility, the X-705 Decontamination Facility, and the X-720 Maintenance and Stores Facility. As uranium operations are performed within these facilities, the potential for a criticality accident exists. In the event of a criticality accident within one of these facilities at PORTS, a Criticality Accident Alarm System (CAAS) is in place to detect the criticality accident and sound an alarm. In this report, an analysis was performed to provide verification that the existing CAAS at PORTS provides complete criticality accident coverage in the X-700, X-705, and X-720 facilities. The analysis has determined that the X-705 and X-720 facilities have complete CAAS coverage; the X-700 facility has not been shown to have complete CAAS coverage at this time.

  13. Bibliography for nuclear criticality accident experience, alarm systems, and emergency management

    SciTech Connect

    Putman, V.L.

    1995-09-01

    The characteristics, detection, and emergency management of nuclear criticality accidents outside reactors has been an important component of criticality safety for as long as the need for this specialized safety discipline has been recognized. The general interest and importance of such topics receives special emphasis because of the potentially lethal, albeit highly localized, effects of criticality accidents and because of heightened public and regulatory concerns for any undesirable event in nuclear and radiological fields. This bibliography lists references which are potentially applicable to or interesting for criticality alarm, detection, and warning systems; criticality accident emergency management; and their associated programs. The lists are annotated to assist bibliography users in identifying applicable: industry and regulatory guidance and requirements, with historical development information and comments; criticality accident characteristics, consequences, experiences, and responses; hazard-, risk-, or safety-analysis criteria; CAS design and qualification criteria; CAS calibration, maintenance, repair, and testing criteria; experiences of CAS designers and maintainers; criticality accident emergency management (planning, preparedness, response, and recovery) requirements and guidance; criticality accident emergency management experience, plans, and techniques; methods and tools for analysis; and additional bibliographies.

  14. Talking Fire Alarms Calm Kids.

    ERIC Educational Resources Information Center

    Executive Educator, 1984

    1984-01-01

    The new microprocessor-based fire alarm systems can help to control smoke movement throughout school buildings by opening vents and doors, identify the burning section, activate voice alarms, provide firefighters with telephone systems during the fire, and release fire-preventing gas. (KS)

  15. The monitoring and alarm system based on distributed temperature fiber sensing

    NASA Astrophysics Data System (ADS)

    Zhao, Hong-qiang; Zhao, Yu-liang; Zhang, Yu-ye; Wang, Shu-juan

    2014-09-01

    Air material depot is a warehouse which store consumed all the parts and equipment vault of the plane. In order to ensure the various aviation equipment integrity of the backup piece rate, the inside temperature of depot must be controlled within a certain range. Therefore, the depot must be equipped a self-contained temperature real-time monitoring system. This paper presents a distributed temperature sensing alarm system to apply to real-time measure spatial distribution of temperature field. In order to eliminate influence to the scattering strength from the light source instability and the fiber bending splice loss and to improve temperature measurement accuracy, the system design used dual-channel dual- wavelength comparison method which make Anti-Stokes as signal channel and Stokes as a reference channel to collect signals of two channel respectively and detect the ratio of the two channels' signals. The light of LD directional coupling to the sensing optical fiber in the temperature field to test, domain reflect light from the sensing optical fiber directional coupling to receive channel again, Rayleigh domain reflect light is filtered after optical filter, the Anti-Stokes and Stokes are both taken out, converted and magnified, the two signals is digitalized by A/D Converter, and written to the storage machine , which linear cumulative to the content of the storage unit, The distributed measurement of the temperature field to test is finished. The collected 2900 measuring points real-time on 2km of optical fiber. The spatial resolution of the system was 0.7m, measurement range was -20-370°C, and measurement error was ± 2 °C. All index of the system achieved the desired objective. To get an accurate temperature field spatial distribution and the information of temporal variation, the system enabled real-time temperature of aviation depot monitoring and early warning . As a new sensing technology, the distributed fiber optic sensor has the functions of self

  16. Make an Alarm! Grades 3-5.

    ERIC Educational Resources Information Center

    Rushton, Erik; Ryan, Emily; Swift, Charles

    After reading the story "Dear Mr. Henshaw" by Beverly Cleary, students build an alarm system for something in the classroom as the main character, Leigh, does to protect his lunchbox from thieves. Students learn about alarms and use their creativity to create an alarm system to protect their lockers, desk, or classroom door. This activity uses a…

  17. Ultrasonic Technology in Duress Alarms.

    ERIC Educational Resources Information Center

    Lee, Martha A.

    2000-01-01

    Provides the pros and cons of the most commonly used technologies in personal duress alarm systems in the school environment. Discussed are radio frequency devices, infrared systems, and ultrasonic technology. (GR)

  18. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  19. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  20. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  1. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  2. 24 CFR 3285.703 - Smoke alarms.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Smoke alarms. 3285.703 Section 3285... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Electrical Systems and Equipment § 3285.703 Smoke alarms. Smoke alarms must be functionally tested in accordance with applicable requirements of the...

  3. 46 CFR 129.530 - General alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false General alarm. 129.530 Section 129.530 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Miscellaneous Electrical Systems § 129.530 General alarm. Each vessel must be fitted with a general alarm...

  4. 46 CFR 129.530 - General alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm. 129.530 Section 129.530 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Miscellaneous Electrical Systems § 129.530 General alarm. Each vessel must be fitted with a general alarm...

  5. Improved alarm tracking for better accountability

    SciTech Connect

    Nemesure, S.; Marr, G.; Shrey, T.; Kling, N.; Hammons, L.; Ingrassia, P.; D'Ottavio, T.

    2011-03-28

    An alarm system is a vital component of any accelerator, as it provides a warning that some element of the system is not functioning properly. The severity and age of the alarm may sometimes signify whether urgent or deferred attention is required. For example, older alarms may be given a lower priority if an assumption is made that someone else is already investigating it, whereas those of higher severity or alarms that are more current may indicate the need for an immediate response. The alarm history also provides valuable information regarding the functionality of the overall system, thus careful tracking of these data is likely to improve response time, remove uncertainty about the current status and assist in the ability to promptly respond to the same warning/trigger in the future. Since one goal of every alarm display is to be free of alarms, a clear and concise presentation of an alarm along with useful historic annotations can help the end user address the warning more quickly, thus expediting the elimination of such alarm conditions. By defining a discrete set of very specific alarm management states and by utilizing database resources to maintain a complete and easily accessible alarm history, we anticipate facilitated work flow due to more efficient operator response and management of alarms.

  6. Evaluation of Neutron Response of Criticality Accident Alarm System Detector to Quasi-Monoenergetic 24 keV Neutrons

    NASA Astrophysics Data System (ADS)

    Tsujimura, Norio; Yoshida, Tadayoshi; Yashima, Hiroshi

    The criticality accident alarm system (CAAS), which was recently developed and installed at the Japan Atomic Energy Agency's Tokai Reprocessing Plant, consists of a plastic scintillator combined with a cadmium-lined polyethylene moderator and thereby responds to both neutrons and gamma rays. To evaluate the neutron absorbed dose rate response of the CAAS detector, a 24 keV quasi-monoenergetic neutron irradiation experiment was performed at the B-1 facility of the Kyoto University Research Reactor. The detector's evaluated neutron response was confirmed to agree reasonably well with prior computer-predicted responses.

  7. Implementation guidance for industrial-level security systems using radio frequency alarm links

    SciTech Connect

    Swank, R.G.

    1996-07-12

    Spread spectrum (SS) RF transmission technologies have properties that make the transmitted signal difficult to intercept, interpret, and jam. The digital code used in the modulation process results in a signal that has high reception reliability and supports multiple use of frequency bands and selective addressing. These attributes and the relatively low installation cost of RF systems make SSRF technologies candidate for communications links in security systems used for industrial sites, remote locations, and where trenching or other disturbances of soil or structures may not be desirable or may be costly. This guide provides a description of such a system and presents implementation methods that may be of engineering benefit.

  8. Statistical Considerations in Designing Tests of Mine Detection Systems: II - Measures Related to the False Alarm Rate

    SciTech Connect

    Simonson, K.M.

    1998-08-01

    The rate at which a mine detection system falsely identifies man-made or natural clutter objects as mines is referred to as the system's false alarm rate (FAR). Generally expressed as a rate per unit area or time, the FAR is one of the primary metrics used to gauge system performance. In this report, an overview is given of statistical methods appropriate for the analysis of data relating to FAR. Techniques are presented for determining a suitable size for the clutter collection area, for summarizing the performance of a single sensor, and for comparing different sensors. For readers requiring more thorough coverage of the topics discussed, references to the statistical literature are provided. A companion report addresses statistical issues related to the estimation of mine detection probabilities.

  9. Alarm acknowledgement in a nuclear plant control room

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    Alarm acknowledgment can be made not only at the alarm tile array of a given console but via other touch sensitive alarm indications in the screen displays of the monitoring system at the same or other consoles; also, touching one tile can acknowledge multiple alarm sources.

  10. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable leakage current alarm. 870.2640 Section... leakage current alarm. (a) Identification. A portable leakage current alarm is a device used to measure the electrical leakage current between any two points of an electrical system and to sound an alarm...

  11. 46 CFR 169.732 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.”...

  12. 46 CFR 169.732 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 169.732 Section 169.732 Shipping... Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide alarm. Each carbon dioxide alarm must be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.”...

  13. Hypo- and Hyperglycemic Alarms

    PubMed Central

    Howsmon, Daniel; Bequette, B. Wayne

    2015-01-01

    Soon after the discovery that insulin regulates blood glucose by Banting and Best in 1922, the symptoms and risks associated with hypoglycemia became widely recognized. This article reviews devices to warn individuals of impending hypo- and hyperglycemia; biosignals used by these devices include electroencephalography, electrocardiography, skin galvanic resistance, diabetes alert dogs, and continuous glucose monitors (CGMs). While systems based on other technology are increasing in performance and decreasing in size, CGM technology remains the best method for both reactive and predictive alarming of hypo- or hyperglycemia. PMID:25931581

  14. The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints.

    PubMed

    Najeeb Al Hallak, Mohammed; McCurdy, Matt; Zouain, Nicolas; Hayes, Justin

    2009-08-28

    (153)Sm-EDTMP is a radiopharmaceutical composed of EDTMP (ethylenediamine-tetramethylenephosphonate) and Samarium-153 [1]. (153)Sm-EDTMP has an affinity for skeletal tissue and concentrates in areas with increased bone turnover; thus, it is successfully used in relieving pain related to diffuse bone metastases [1]. The manufacturing process of (153)Sm-EDTMP leads to contamination with (154)Eu (Europium-154) [2]. A previous study only alluded to the retention of (154)Eu in the bones after receiving treatment with (153)Sm-EDTMP [2]. Activation of the alarm at security checkpoints after (153)Sm-EDTMP therapy has not been previously reported. Two out of 15 patients who received (153)Sm-EDTMP at Roger Maris Cancer Center (Fargo, N. Dak., USA) activated the radiation activity sensors while passing through checkpoints; one at a US airport and the other while crossing the American-Canadian border. We assume that the (154)Eu which remained in the patients' bones activated the sensors. METHODS: In order to investigate this hypothesis, we obtained the consent from 3 of our 15 patients who received (153)Sm-EDTMP within the previous 4 months to 2 years, including the patient who had activated the radiation alarm at the airport. The patients were scanned with a handheld detector and a gamma camera for energies from 511 keV to 1.3 MeV. RESULTS: All three patients exhibited identical spectral images, and further analysis showed that the observed spectra are the result of (154)Eu emissions. CONCLUSION: Depending on the detection thresholds and windows used by local and federal authorities, the remaining activity of (154)Eu retained in patients who received (153)Sm-EDTMP could be sufficient enough to increase the count rates above background levels and activate the sensors. At Roger Maris Cancer Center, patients are now informed of the potential consequences of (153)Sm-EDTMP therapy prior to initiating treatment. In addition, patients treated with (153)Sm-EDTMP at Roger Maris Cancer

  15. Multistation alarm system for eruptive activity based on the automatic classification of volcanic tremor: specifications and performance

    NASA Astrophysics Data System (ADS)

    Langer, Horst; Falsaperla, Susanna; Messina, Alfio; Spampinato, Salvatore

    2015-04-01

    With over fifty eruptive episodes (Strombolian activity, lava fountains, and lava flows) between 2006 and 2013, Mt Etna, Italy, underscored its role as the most active volcano in Europe. Seven paroxysmal lava fountains at the South East Crater occurred in 2007-2008 and 46 at the New South East Crater between 2011 and 2013. Month-lasting lava emissions affected the upper eastern flank of the volcano in 2006 and 2008-2009. On this background, effective monitoring and forecast of volcanic phenomena are a first order issue for their potential socio-economic impact in a densely populated region like the town of Catania and its surroundings. For example, explosive activity has often formed thick ash clouds with widespread tephra fall able to disrupt the air traffic, as well as to cause severe problems at infrastructures, such as highways and roads. For timely information on changes in the state of the volcano and possible onset of dangerous eruptive phenomena, the analysis of the continuous background seismic signal, the so-called volcanic tremor, turned out of paramount importance. Changes in the state of the volcano as well as in its eruptive style are usually concurrent with variations of the spectral characteristics (amplitude and frequency content) of tremor. The huge amount of digital data continuously acquired by INGV's broadband seismic stations every day makes a manual analysis difficult, and techniques of automatic classification of the tremor signal are therefore applied. The application of unsupervised classification techniques to the tremor data revealed significant changes well before the onset of the eruptive episodes. This evidence led to the development of specific software packages related to real-time processing of the tremor data. The operational characteristics of these tools - fail-safe, robustness with respect to noise and data outages, as well as computational efficiency - allowed the identification of criteria for automatic alarm flagging. The

  16. Development of a Novel Alarm System to Improve Adaptation to Non-invasive Ventilation in Patients With High Cervical Spinal Cord Injury

    PubMed Central

    2016-01-01

    In this case report, we want to introduce a successful way of applying non-invasive ventilation (NIV) with a full face mask in patients with high cervical spinal cord injury through a novel alarm system for communication. A 57-year-old man was diagnosed with C3 American Spinal Injury Association impairment scale (AIS) B. We applied NIV for treatment of hypercapnia. Because of mouth opening during sleep, a full face mask was the only way to use NIV. However, he could not take off the mask by himself, and this situation caused great fear. To solve this problem, we designed a novel alarm system. The best intended motion of the patient was neck rotation. Sensing was performed by a balloon sensor placed under the head of the patient. A beep sound was generated whenever the pressure was above the threshold, and more than three consecutive beeps within 3,000 ms created a loud alarm for caregivers. PMID:27847728

  17. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, A.; Moses, H. R.

    2016-01-01

    Currently on the International Space Station (ISS) and other space vehicles Caution & Warning (C&W) alerts are represented with various auditory tones that correspond to the type of event. This system relies on the crew's ability to remember what each tone represents in a high stress, high workload environment when responding to the alert. Furthermore, crew receive a year or more in advance of the mission that makes remembering the semantic meaning of the alerts more difficult. The current system works for missions conducted close to Earth where ground operators can assist as needed. On long duration missions, however, they will need to work off-nominal events autonomously. There is evidence that speech alarms may be easier and faster to recognize, especially during an off-nominal event. The Information Presentation Directed Research Project (FY07-FY09) funded by the Human Research Program included several studies investigating C&W alerts. The studies evaluated tone alerts currently in use with NASA flight deck displays along with candidate speech alerts. A follow-on study used four types of speech alerts to investigate how quickly various types of auditory alerts with and without a speech component - either at the beginning or at the end of the tone - can be identified. Even though crew were familiar with the tone alert from training or direct mission experience, alerts starting with a speech component were identified faster than alerts starting with a tone. The current study replicated the results from the previous study in a more rigorous experimental design to determine if the candidate speech alarms are ready for transition to operations or if more research is needed. Four types of alarms (caution, warning, fire, and depressurization) were presented to participants in both tone and speech formats in laboratory settings and later in the Human Exploration Research Analog (HERA). In the laboratory study, the alerts were presented by software and participants were

  18. Understanding Clinical Alarm Safety.

    PubMed

    Lukasewicz, Carol L; Mattox, Elizabeth Andersson

    2015-08-01

    Patient safety organizations and health care accreditation agencies recognize the significance of clinical alarm hazards. The Association for the Advancement of Medical Instrumentation, a nonprofit organization focused on development and use of safe and effective medical equipment, identifies alarm management as a major issue for health care organizations. ECRI Institute, a nonprofit organization that researches approaches for improving patient safety and quality of care, identifies alarm hazards as the most significant of the "Top Ten Health Technology Hazards" for 2014. A new Joint Commission National Patient Safety Goal focusing on clinical alarm safety contains new requirements for accredited hospitals to be fully implemented by 2016. Through a fictional unfolding case study, this article reviews selected contributing factors to clinical alarm hazards present in inpatient, high-acuity settings. Understanding these factors improves contributions by nurses to clinical alarm safety practice.

  19. 46 CFR 113.25-30 - General emergency alarm systems for barges of 300 or more gross tons with sleeping accommodations...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... more gross tons with sleeping accommodations for more than six persons. 113.25-30 Section 113.25-30... for barges of 300 or more gross tons with sleeping accommodations for more than six persons. The general emergency alarm system for a barge of 300 or more gross tons with sleeping accommodations for...

  20. 46 CFR 113.25-30 - General emergency alarm systems for barges of 300 or more gross tons with sleeping accommodations...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... more gross tons with sleeping accommodations for more than six persons. 113.25-30 Section 113.25-30... for barges of 300 or more gross tons with sleeping accommodations for more than six persons. The general emergency alarm system for a barge of 300 or more gross tons with sleeping accommodations for...

  1. 46 CFR 113.25-30 - General emergency alarm systems for barges of 300 or more gross tons with sleeping accommodations...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... more gross tons with sleeping accommodations for more than six persons. 113.25-30 Section 113.25-30... for barges of 300 or more gross tons with sleeping accommodations for more than six persons. The general emergency alarm system for a barge of 300 or more gross tons with sleeping accommodations for...

  2. 46 CFR 113.25-30 - General emergency alarm systems for barges of 300 or more gross tons with sleeping accommodations...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... more gross tons with sleeping accommodations for more than six persons. 113.25-30 Section 113.25-30... for barges of 300 or more gross tons with sleeping accommodations for more than six persons. The general emergency alarm system for a barge of 300 or more gross tons with sleeping accommodations for...

  3. 46 CFR 113.25-30 - General emergency alarm systems for barges of 300 or more gross tons with sleeping accommodations...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... more gross tons with sleeping accommodations for more than six persons. 113.25-30 Section 113.25-30... for barges of 300 or more gross tons with sleeping accommodations for more than six persons. The general emergency alarm system for a barge of 300 or more gross tons with sleeping accommodations for...

  4. Bed exit alarms.

    PubMed

    2004-09-01

    Bed-exit alarms alert caregivers that a patient who should not get out of bed unassisted is doing so. These alarms can help reduce the likelihood of falls and can promote speedy assistance to patients who have already fallen. But as we described in our May 2004 Guidance Article on bed-exit alarms, they don't themselves prevent falls. They are only effective if used as part of an overall fall-prevention program and with a clear understanding of their limitations. This Evaluation examines the effectiveness of 16 bed-exit alarms from seven suppliers. Our ratings focus primarily on each product's reliability in detecting bed-exit events and alerting caregivers, its ability to minimize nuisance alarms (alarms that sound even though the patient isn't leaving the bed or that sound while a caregiver is helping the patient to leave the bed), and its resistance to deliberate or inadvertent tampering. Twelve of the products use pressure-sensor-activated alarms (mainly sensor pads placed on or under the mattress); three use a cord that can attach to the patient's garment, alarming if the cord is pulled loose from the control unit; and one is a position-sensitive alarm attached to a leg cuff. All the products reliably detect attempted or successful bed exits. But they vary greatly in how effectively they alert staff, minimize nuisance alarms, and resist tampering. Ease of use and battery performance also vary for many units. Of the pressure-sensor units, three are rated Preferred. Those units meet most of our criteria and have no significant disadvantages. Five of the other pressure-sensor products are Acceptable, and the remaining four are Not Recommended. All three cord-activated alarms are rated Acceptable, as is the patient-worn alarm.

  5. 46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... provided a smoke detecting or other suitable type fire detecting system. (c) Enclosed spaces which are “specially suitable for vehicles” shall be fitted with an approved fire or smoke detecting system....

  6. Alarming increase in refugees.

    PubMed

    1992-01-01

    swamp reception systems. There was a growing phenomenon of "asylum shopping" -- people turned down by 1 country applying to another and another. The cost of supporting applicants on welfare while their claims were processing was rising. In 1990 there were some 800,000 foreigners in Germany alone whose claims were under consideration.

  7. Black Juveniles in the Juvenile Justice System: A Cause for Alarm.

    ERIC Educational Resources Information Center

    LeFlore, Larry

    This report examines the representation of black youth in the juvenile justice system, describes changes in juvenile justice philosophy, and discusses policy implications. Black youth are overrepresented at all stages of the juvenile justice system compared to white youth. Positivist theories explain this overrepresentation as the result of…

  8. False alarms and missed events: the impact and origins of perceived inaccuracy in tornado warning systems.

    PubMed

    Ripberger, Joseph T; Silva, Carol L; Jenkins-Smith, Hank C; Carlson, Deven E; James, Mark; Herron, Kerry G

    2015-01-01

    Theory and conventional wisdom suggest that errors undermine the credibility of tornado warning systems and thus decrease the probability that individuals will comply (i.e., engage in protective action) when future warnings are issued. Unfortunately, empirical research on the influence of warning system accuracy on public responses to tornado warnings is incomplete and inconclusive. This study adds to existing research by analyzing two sets of relationships. First, we assess the relationship between perceptions of accuracy, credibility, and warning response. Using data collected via a large regional survey, we find that trust in the National Weather Service (NWS; the agency responsible for issuing tornado warnings) increases the likelihood that an individual will opt for protective action when responding to a hypothetical warning. More importantly, we find that subjective perceptions of warning system accuracy are, as theory suggests, systematically related to trust in the NWS and (by extension) stated responses to future warnings. The second half of the study matches survey data against NWS warning and event archives to investigate a critical follow-up question--Why do some people perceive that their warning system is accurate, whereas others perceive that their system is error prone? We find that subjective perceptions are--in part-a function of objective experience, knowledge, and demographic characteristics. When considered in tandem, these findings support the proposition that errors influence perceptions about the accuracy of warning systems, which in turn impact the credibility that people assign to information provided by systems and, ultimately, public decisions about how to respond when warnings are issued.

  9. Alarmin(g) the innate immune system to invasive fungal infections.

    PubMed

    Caffrey, Alayna K; Obar, Joshua J

    2016-08-01

    Fungi encounter numerous stresses in a mammalian host, including the immune system, which they must adapt to in order to grow and cause disease. The host immune system tunes its response to the threat level posed by the invading pathogen. We discuss recent findings on how interleukin (IL)-1 signaling is central to tuning the immune response to the virulence potential of invasive fungi, as well as other pathogens. Moreover, we discuss fungal factors that may drive tissue invasion and destruction that regulate IL-1 cytokine release. Moving forward understanding the mechanisms of fungal adaption to the host, together with understanding how the host innate immune system recognizes invading fungal pathogens will increase our therapeutic options for treatment of invasive fungal infections.

  10. 46 CFR 95.15-30 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) Spaces which are protected by a carbon... audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to... sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and...

  11. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  12. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  13. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  14. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  15. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  16. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  17. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  18. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  19. 46 CFR 95.15-30 - Alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) Spaces which are protected by a carbon... audible alarm in such spaces which will be automatically sounded when the carbon dioxide is admitted to... sound during the 20 second delay period prior to the discharge of carbon dioxide into the space, and...

  20. 46 CFR 130.450 - Machinery alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Machinery alarms. 130.450 Section 130.450 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.450 Machinery alarms....

  1. 46 CFR 130.470 - Fire alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire alarms. 130.470 Section 130.470 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS VESSEL CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Automation of Unattended Machinery Spaces § 130.470 Fire alarms. (a)...

  2. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Alarm and means of escape. (a) Each CO2 system that has a supply of more than 136 kilograms (300 pounds) of CO2, except a system that protects a tank, must have an alarm that sounds for at least 20 seconds before the CO2 is released into the space. (b) Each audible alarm for a CO2 system must have the...

  3. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Alarm and means of escape. (a) Each CO2 system that has a supply of more than 136 kilograms (300 pounds) of CO2, except a system that protects a tank, must have an alarm that sounds for at least 20 seconds before the CO2 is released into the space. (b) Each audible alarm for a CO2 system must have the...

  4. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Alarm and means of escape. (a) Each CO2 system that has a supply of more than 136 kilograms (300 pounds) of CO2, except a system that protects a tank, must have an alarm that sounds for at least 20 seconds before the CO2 is released into the space. (b) Each audible alarm for a CO2 system must have the...

  5. False alarm reduction in critical care.

    PubMed

    Clifford, Gari D; Silva, Ikaro; Moody, Benjamin; Li, Qiao; Kella, Danesh; Chahin, Abdullah; Kooistra, Tristan; Perry, Diane; Mark, Roger G

    2016-08-01

    High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 PhysioNet/Computing in Cardiology Challenge provides a set of 1250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppression using all available signals. Each data segment was 5 minutes long (for real time analysis), ending at the time of the alarm. For retrospective analysis, we provided a further 30 seconds of data after the alarm was triggered. A total of 750 data segments were made available for training and 500 were held back for testing. Each alarm was reviewed by expert annotators, at least two of whom agreed that the alarm was either true or false. Challenge participants were invited to submit a complete, working algorithm to distinguish true from false alarms, and received a score based on their program's performance on the hidden test set. This score was based on the percentage of alarms correct, but with a penalty that weights the suppression of true alarms five times more heavily than acceptance of false alarms. We provided three example entries based on well-known, open source signal processing algorithms, to serve as a basis for comparison and as a starting point for participants to develop their own code. A total of 38 teams submitted a total of 215 entries in this year's Challenge. This editorial reviews the background issues for this challenge, the design of the challenge itself, the key achievements, and the follow-up research generated as a result of the Challenge, published in the concurrent special issue of Physiological Measurement. Additionally we make some recommendations for future changes in the field of patient monitoring as a result of the Challenge.

  6. 46 CFR 76.35-10 - Location and spacing of manual alarm boxes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Location and spacing of manual alarm boxes. 76.35-10... PROTECTION EQUIPMENT Manual Alarm System, Details § 76.35-10 Location and spacing of manual alarm boxes. (a) There shall be at least one manual alarm box in each zone. (b) Manual alarms shall be located in...

  7. 8. INTERIOR, FIRE ALARM CONTROL ROOM (NORTH OF MAIN GARAGE), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. INTERIOR, FIRE ALARM CONTROL ROOM (NORTH OF MAIN GARAGE), FROM ENTRYWAY, LOOKING NORTH, SHOWING ADDITIONAL 'GAMEWELL' FIRE ALARM SYSTEMS. - Oakland Naval Supply Center, Firehouse, East of Fourth Street, between A & B Streets, Oakland, Alameda County, CA

  8. Study on Mobile Object Positioning and Alarming System Based on the “Map World” in the Core Area of the Silk Road Economic Belt

    NASA Astrophysics Data System (ADS)

    Mu, Kai

    2017-02-01

    The established “Map World” on the National Geographic Information Public Service Platform offers free access to many geographic information in the Core Area of the Silk Road Economic Belt. Considering the special security situation and severe splittism and anti-splittism struggles in the Core Area of the Silk Road Economic Belt, a set of moving target positioning and alarming platform based on J2EE platform and B/S structure was designed and realized by combining the “Map World” data and global navigation satellite system. This platform solves various problems, such as effective combination of Global Navigation Satellite System (GNSS) and “Map World” resources, moving target alarming setting, inquiry of historical routes, system management, etc.

  9. Sequence and batch language programs and alarm-related ``C`` programs for the 242-A MCS. Revision 2

    SciTech Connect

    Berger, J.F.

    1995-03-01

    A Distributive Process Control system was purchased by Project B-534, ``242-A Evaporator/Crystallizer Upgrades``. This control system, called the Monitor and Control System (MCS), was installed in the 242-A Evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict the overall process. To do this, WTSE developed a second alarm scheme which uses special programs, annunciator keys, and process graphics. The special programs are written in two languages; Sequence and Batch Language (SABL), and ``C`` language. The WTSE-developed alarm scheme works as described below: SABL relates signals and alarms to the annunciator keys, called SKID keys. When an alarm occurs, a SABL program causes a SKID key to flash, and if the alarm is of yellow or white priority then a ``C`` program turns on an audible horn (the D/3 system uses a different audible horn for the red priority alarms). The horn and flashing key draws the attention of the operator.

  10. Smart smoke alarm

    DOEpatents

    Warmack, Robert J. Bruce; Wolf, Dennis A; Frank, Steven Shane

    2015-04-28

    Methods and apparatus for smoke detection are disclosed. In one embodiment, a smoke detector uses linear discriminant analysis (LDA) to determine whether observed conditions indicate that an alarm is warranted.

  11. Speech Alarms Pilot Study

    NASA Technical Reports Server (NTRS)

    Sandor, Aniko; Moses, Haifa

    2016-01-01

    Speech alarms have been used extensively in aviation and included in International Building Codes (IBC) and National Fire Protection Association's (NFPA) Life Safety Code. However, they have not been implemented on space vehicles. Previous studies conducted at NASA JSC showed that speech alarms lead to faster identification and higher accuracy. This research evaluated updated speech and tone alerts in a laboratory environment and in the Human Exploration Research Analog (HERA) in a realistic setup.

  12. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  13. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  14. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  15. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  16. 46 CFR 169.730 - General alarm bell switch.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false General alarm bell switch. 169.730 Section 169.730... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.730 General alarm bell switch. On vessels of 100 gross tons and over there must be a general alarm bell switch in the pilothouse,...

  17. 46 CFR 119.530 - Bilge high level alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge high level alarms. 119.530 Section 119.530... Bilge and Ballast Systems § 119.530 Bilge high level alarms. (a) Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the...

  18. The problem of alarm fatigue.

    PubMed

    Tanner, Tanya

    2013-01-01

    Up to 99 percent of alarms sounding on hospital units are false alarms signaling no real danger to patients. These false alarms can lead to alarm fatigue and alarm burden, and may divert health care providers' attention away from significant alarms heralding actual or impending harm. As the health care environment continues to become more dependent upon technological monitoring devices used for patient care, nurses must become aware of the possibility and consequences of alarm fatigue and ways to prevent it from negatively affecting their practice, as well as the possible consequences for patient care.

  19. MRDIS Standalone Central Alarm Station

    SciTech Connect

    2012-09-12

    The MRDIS Standalone Central Alarm Station(MRDIS-CAS} is a software system for receiving, storing, and reviewing radiation data collected by the Mobile Radiation Detection and Identification System (MRDIS}, a mobile radiation scanning system developed for use in foreign ports for the DOE Megaports Initiative. It is designed to run on one of the on board computers in the MRDIS cab. It will collect, store, and display data from the MRDIS without the need for wireless communications or centralized server technology. It is intended to be a lightweight replacement for a distributed Megaports communication system in ports where the necessary communications infrastructure does not exist for a full Megaports communications system.

  20. Alarm points for fixed oxygen monitors

    SciTech Connect

    Miller, G.C.

    1987-05-01

    Oxygen concentration monitors were installed in a vault where numerous pipes carried inert cryogens and gases to the Mirror Fusion Test Facility (MFTF-B) experimental vessel at Lawrence Livermore National Laboratory (LLNL). The problems associated with oxygen-monitoring systems and the reasons why such monitors were installed were reviewed. As a result of this review, the MFTF-B monitors were set to sound an evacuation alarm when the oxygen concentration fell below 18%. We chose the 18% alarm criterion to minimize false alarms and to allow time for personnel to escape in an oxygen-deficient environment.

  1. Clinical Alarms in Intensive Care Units: Perceived Obstacles of Alarm Management and Alarm Fatigue in Nurses

    PubMed Central

    Cho, Ok Min; Lee, Young Whee; Cho, Insook

    2016-01-01

    Objectives The purpose of this descriptive study was to investigate the current situation of clinical alarms in intensive care unit (ICU), nurses' recognition of and fatigue in relation to clinical alarms, and obstacles in alarm management. Methods Subjects were ICU nurses and devices from 48 critically ill patient cases. Data were collected through direct observation of alarm occurrence and questionnaires that were completed by the ICU nurses. The observation time unit was one hour block. One bed out of 56 ICU beds was randomly assigned to each observation time unit. Results Overall 2,184 clinical alarms were counted for 48 hours of observation, and 45.5 clinical alarms occurred per hour per subject. Of these, 1,394 alarms (63.8%) were categorized as false alarms. The alarm fatigue score was 24.3 ± 4.0 out of 35. The highest scoring item was "always get bothered due to clinical alarms". The highest scoring item in obstacles was "frequent false alarms, which lead to reduced attention or response to alarms". Conclusions Nurses reported that they felt some fatigue due to clinical alarms, and false alarms were also obstacles to proper management. An appropriate hospital policy should be developed to reduce false alarms and nurses' alarm fatigue. PMID:26893950

  2. Smart alarms from medical devices in the OR and ICU.

    PubMed

    Imhoff, Michael; Kuhls, Silvia; Gather, Ursula; Fried, Roland

    2009-03-01

    Alarms in medical devices are a matter of concern in critical and perioperative care. The high rate of false alarms is not only a nuisance for patients and caregivers, but can also compromise patient safety and effectiveness of care. The development of alarm systems has lagged behind the technological advances of medical devices over the last 20 years. From a clinical perspective, major improvements in alarm algorithms are urgently needed. This review gives an overview of the current clinical situation and the underlying problems, and discusses different methods from statistics and computational science and their potential for clinical application. Some examples of the application of new alarm algorithms to clinical data are presented.

  3. Dual sensitivity mode system for monitoring processes and sensors

    DOEpatents

    Wilks, Alan D.; Wegerich, Stephan W.; Gross, Kenneth C.

    2000-01-01

    A method and system for analyzing a source of data. The system and method involves initially training a system using a selected data signal, calculating at least two levels of sensitivity using a pattern recognition methodology, activating a first mode of alarm sensitivity to monitor the data source, activating a second mode of alarm sensitivity to monitor the data source and generating a first alarm signal upon the first mode of sensitivity detecting an alarm condition and a second alarm signal upon the second mode of sensitivity detecting an associated alarm condition. The first alarm condition and second alarm condition can be acted upon by an operator and/or analyzed by a specialist or computer program.

  4. Analysis of criticality accident alarm system coverage of the X-744G, X-744H, X-342/344A and X-343 facilities at the Portsmouth Gaseous Diffusion Plant

    SciTech Connect

    Dobelbower, M.C.; Woollard, J.; Lee, B.L. Jr.; Tayloe, R.W. Jr.

    1995-09-01

    Additional services for the uranium enrichment cascade process, such as UF{sub 6} feed, sampling, and material storage are provided by several ancillary Uranium Material Handling (UMH) facilities at the PORTS site. These facilities include the X-343 Feed Vaporization and Sampling Facility, the X-744G Bulk Non-Uranium Enrichment Service Activity (UESA) Storage Building, the X-744H Waste Separation and Storage Facility, the X-344A Toll Enrichment Services Facility and the X-342A Feed Vaporization and Fluorine Generation Facility. As uranium operations are performed within these facilities, the potential for a criticality accident exists. In the event of a criticality accident within a process facility at PORTS, a Criticality Accident Alarm System (CAAS) is in place to detect the criticality accident and sound an alarm. In this report, an analysis was performed to provide verification that the existing CAAS at PORTS provides complete criticality accident coverage in the X-343, X-744G. X-744H. X-344A and X-342A facilities. The analysis has determined that all of the above-mentioned facilities have complete CAAS coverage.

  5. Control of ELT false alarms

    NASA Technical Reports Server (NTRS)

    Toth, S.; Gershkoff, I.

    1979-01-01

    The statistics of emergency locator transmitter (ELT) alarms are presented. The primary sources of data include ELT Incident Logs, Service Difficulty Reports, and Frequency Interference Reports. The number of reported and unreported alarms is discussed, as are seasonal variations, duration of ELT transmissions, and cost of silencing. Origin, causes, and possible strategies for reducing the impact of alarms on the aviation community are considered.

  6. HOME INSECURITY: NO ALARMS, FALSE ALARMS, AND SIGINT

    SciTech Connect

    Lamb, Logan M

    2014-01-01

    The market share of home security systems has substantially increased as vendors incorporate more desirable features: intrusion detection, automation, wireless, and LCD touch panel controls. Wireless connectivity allows vendors to manufacture cheaper, more featureful products that require little to no home modification to install. Consumer win, since adding devices is easier. The result: an ostensibly more secure, convenient, and connected home for a larger number of citizens. Sadly, this hypothesis is flawed; the idea of covering a home with more security sensors does not translate into a more secure home. Additionally, the number of homes using these vulnerable systems is large, and the growth rate is increasing producing a even larger problem. In this talk, I will demonstrate a generalized approach for compromising three systems: ADT, the largest home security dealer in North America; Honeywell, one of the largest manufacturers of security devices; and Vivint, a top 5 security dealer. We will suppress alarms, create false alarms, and collect artifacts that facilitate tracking the movements of individuals in their homes.

  7. Sequence and batch language programs and alarm related C Programs for the 242-A MCS

    SciTech Connect

    Berger, J.F.

    1996-04-15

    A Distributive Process Control system was purchased by Project B-534, 242-A Evaporator/Crystallizer Upgrades. This control system, called the Monitor and Control system (MCS), was installed in the 242-A evaporator located in the 200 East Area. The purpose of the MCS is to monitor and control the Evaporator and monitor a number of alarms and other signals from various Tank Farm facilities. Applications software for the MCS was developed by the Waste Treatment Systems Engineering (WTSE) group of Westinghouse. The standard displays and alarm scheme provide for control and monitoring, but do not directly indicate the signal location or depict the overall process. To do this, WTSE developed a second alarm scheme.

  8. Fault Diagnosis with Multi-State Alarms in a Nuclear Power Control Simulation

    SciTech Connect

    Stuart A. Ragsdale; Roger Lew; Ronald L. Boring

    2014-09-01

    This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effects of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized the use of three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. Sensitivity and criterion based on the Signal Detection Theory were used to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed better and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.

  9. FAULT DIAGNOSIS WITH MULTI-STATE ALARMS IN A NUCLEAR POWER CONTROL SIMULATOR

    SciTech Connect

    Austin Ragsdale; Roger Lew; Brian P. Dyre; Ronald L. Boring

    2012-10-01

    This research addresses how alarm systems can increase operator performance within nuclear power plant operations. The experiment examined the effect of two types of alarm systems (two-state and three-state alarms) on alarm compliance and diagnosis for two types of faults differing in complexity. We hypothesized three-state alarms would improve performance in alarm recognition and fault diagnoses over that of two-state alarms. We used sensitivity and criterion based on Signal Detection Theory to measure performance. We further hypothesized that operator trust would be highest when using three-state alarms. The findings from this research showed participants performed better and had more trust in three-state alarms compared to two-state alarms. Furthermore, these findings have significant theoretical implications and practical applications as they apply to improving the efficiency and effectiveness of nuclear power plant operations.

  10. Alarm toe switch

    DOEpatents

    Ganyard, Floyd P.

    1982-01-01

    An alarm toe switch inserted within a shoe for energizing an alarm circuit n a covert manner includes an insole mounting pad into which a miniature reed switch is fixedly molded. An elongated slot perpendicular to the reed switch is formed in the bottom surface of the mounting pad. A permanent cylindrical magnet positioned in the forward portion of the slot with a diameter greater than the pad thickness causes a bump above the pad. A foam rubber block is also positioned in the slot rearwardly of the magnet and holds the magnet in normal inoperative relation. A non-magnetic support plate covers the slot and holds the magnet and foam rubber in the slot. The plate minimizes bending and frictional forces to improve movement of the magnet for reliable switch activation. The bump occupies the knuckle space beneath the big toe. When the big toe is scrunched rearwardly the magnet is moved within the slot relative to the reed switch, thus magnetically activating the switch. When toe pressure is released the foam rubber block forces the magnet back into normal inoperative position to deactivate the reed switch. The reed switch is hermetically sealed with the magnet acting through the wall so the switch assembly S is capable of reliable operation even in wet and corrosive environments.

  11. An investigation of training strategies to improve alarm reactions.

    PubMed

    Bliss, James P; Chancey, Eric T

    2014-09-01

    Researchers have suggested that operator training may improve operator reactions; however, researchers have not documented this for alarm reactions. The goal of this research was to train participants to react to alarms using sensor activity patterns. In Experiment 1, 80 undergraduates monitored a simulated security screen while completing a primary word search task. They received spatial, temporal, single sensor, or no training to respond to alarms of differing reliability levels. Analyses revealed more appropriate and quicker reactions when participants were trained and when the alarms were reliable. In Experiment 2, 56 participants practiced time estimation by simple repetition, performance feedback, or performance feedback and temporal subdivision. They then reacted to alarms based on elapsed time between sensor activity and alarm onset. Surprisingly, results indicated that participants did not benefit differentially from temporal interval training, focusing instead on advertised system reliability. Researchers should replicate these findings with realistic tasks and real-world complex task operators.

  12. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  13. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  14. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  15. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  16. 46 CFR 111.33-7 - Alarms and shutdowns.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Alarms and shutdowns. 111.33-7 Section 111.33-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Semiconductor Rectifier Systems § 111.33-7 Alarms and shutdowns. Each power...

  17. You Cannot Always Blame the Equipment for False Alarms

    ERIC Educational Resources Information Center

    Smith, Ray T.

    1976-01-01

    Discusses the need for school administrators to establish definite security objectives before shopping for an electronic alarm system and points out that most problems with alarm systems result from people problems, rather than faulty equipment. (For availability see EA 507 081.) (JG)

  18. Chair alarm for patient fall prevention based on gesture recognition and interactivity.

    PubMed

    Knight, Heather; Lee, Jae-Kyu; Ma, Hongshen

    2008-01-01

    The Gesture Recognition Interactive Technology (GRiT) Chair Alarm aims to prevent patient falls from chairs and wheelchairs by recognizing the gesture of a patient attempting to stand. Patient falls are one of the greatest causes of injury in hospitals. Current chair and bed exit alarm systems are inadequate because of insufficient notification, high false-alarm rate, and long trigger delays. The GRiT chair alarm uses an array of capacitive proximity sensors and pressure sensors to create a map of the patient's sitting position, which is then processed using gesture recognition algorithms to determine when a patient is attempting to stand and to alarm the care providers. This system also uses a range of voice and light feedback to encourage the patient to remain seated and/or to make use of the system's integrated nurse-call function. This system can be seamlessly integrated into existing hospital WiFi networks to send notifications and approximate patient location through existing nurse call systems.

  19. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20...) Automation alarms must be separate and independent of the following: (i) The fire detection and alarm...

  20. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20...) Automation alarms must be separate and independent of the following: (i) The fire detection and alarm...

  1. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20...) Automation alarms must be separate and independent of the following: (i) The fire detection and alarm...

  2. A correlation consistency based multivariate alarm thresholds optimization approach.

    PubMed

    Gao, Huihui; Liu, Feifei; Zhu, Qunxiong

    2016-11-01

    Different alarm thresholds could generate different alarm data, resulting in different correlations. A new multivariate alarm thresholds optimization methodology based on the correlation consistency between process data and alarm data is proposed in this paper. The interpretative structural modeling is adopted to select the key variables. For the key variables, the correlation coefficients of process data are calculated by the Pearson correlation analysis, while the correlation coefficients of alarm data are calculated by kernel density estimation. To ensure the correlation consistency, the objective function is established as the sum of the absolute differences between these two types of correlations. The optimal thresholds are obtained using particle swarm optimization algorithm. Case study of Tennessee Eastman process is given to demonstrate the effectiveness of proposed method.

  3. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  4. 46 CFR 193.15-30 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... board while the vessel is being navigated which are protected by a carbon dioxide extinguishing system... when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally... as to sound during the 20-second delay period prior to the discharge of carbon dioxide into the...

  5. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  6. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  7. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  8. 46 CFR 193.15-30 - Alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... board while the vessel is being navigated which are protected by a carbon dioxide extinguishing system... when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally... as to sound during the 20-second delay period prior to the discharge of carbon dioxide into the...

  9. 46 CFR 76.15-30 - Alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space....

  10. 46 CFR 95.15-30 - Alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... automatically and audibly for at least 20 seconds before carbon dioxide is discharged into the space; (2) Be..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) A protected space must be fitted with...

  11. Monitoring techniques and alarm procedures for CMS Services and Sites in WLCG

    NASA Astrophysics Data System (ADS)

    Molina-Perez, J.; Bonacorsi, D.; Gutsche, O.; Sciabà, A.; Flix, J.; Kreuzer, P.; Fajardo, E.; Boccali, T.; Klute, M.; Gomes, D.; Kaselis, R.; Du, R.; Magini, N.; Butenas, I.; Wang, W.

    2012-12-01

    The CMS offline computing system is composed of roughly 80 sites (including most experienced T3s) and a number of central services to distribute, process and analyze data worldwide. A high level of stability and reliability is required from the underlying infrastructure and services, partially covered by local or automated monitoring and alarming systems such as Lemon and SLS; the former collects metrics from sensors installed on computing nodes and triggers alarms when values are out of range, the latter measures the quality of service and warns managers when service is affected. CMS has established computing shift procedures with personnel operating worldwide from remote Computing Centers, under the supervision of the Computing Run Coordinator at CERN. This dedicated 24/7 computing shift personnel is contributing to detect and react timely on any unexpected error and hence ensure that CMS workflows are carried out efficiently and in a sustained manner. Synergy among all the involved actors is exploited to ensure the 24/7 monitoring, alarming and troubleshooting of the CMS computing sites and services. We review the deployment of the monitoring and alarming procedures, and report on the experience gained throughout the first two years of LHC operation. We describe the efficiency of the communication tools employed, the coherent monitoring framework, the proactive alarming systems and the proficient troubleshooting procedures that helped the CMS Computing facilities and infrastructure to operate at high reliability levels.

  12. 46 CFR 182.530 - Bilge high level alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Bilge high level alarms. 182.530 Section 182.530... TONS) MACHINERY INSTALLATION Bilge and Ballast Systems § 182.530 Bilge high level alarms. (a) On a... operating station to indicate a high water level in each of the following normally unmanned spaces: (1)...

  13. Shadow Probability of Detection and False Alarm for Median-Filtered SAR Imagery

    SciTech Connect

    Raynal, Ann Marie; Doerry, Armin Walter; Miller, John A.; Bishop, Edward E.; Horndt, Volker

    2014-06-01

    Median filtering reduces speckle in synthetic aperture radar (SAR) imagery while preserving edges, at the expense of coarsening the resolution, by replacing the center pixel of a sliding window by the median value. For shadow detection, this approach helps distinguish shadows from clutter more easily, while preserving shadow shape delineations. However, the nonlinear operation alters the shadow and clutter distributions and statistics, which must be taken into consideration when computing probability of detection and false alarm metrics. Depending on system parameters, median filtering can improve probability of detection and false alarm by orders of magnitude. Herein, we examine shadow probability of detection and false alarm in a homogeneous, ideal clutter background after median filter post-processing. Some comments on multi-look processing effects with and without median filtering are also made.

  14. Test processing system (SEE)

    NASA Technical Reports Server (NTRS)

    Gaulene, P.

    1986-01-01

    The SEE data processing system, developed in 1985, manages and process test results. General information is provided on the SEE system: objectives, characteristics, basic principles, general organization, and operation. Full documentation is accessible by computer using the HELP SEE command.

  15. Reducing false alarms in the ICU by quantifying self-similarity of multimodal biosignals.

    PubMed

    Antink, Christoph Hoog; Leonhardt, Steffen; Walter, Marian

    2016-08-01

    False arrhythmia alarms pose a major threat to the quality of care in today's ICU. Thus, the PhysioNet/Computing in Cardiology Challenge 2015 aimed at reducing false alarms by exploiting multimodal cardiac signals recorded by a patient monitor. False alarms for asystole, extreme bradycardia, extreme tachycardia, ventricular flutter/fibrillation as well as ventricular tachycardia were to be reduced using two electrocardiogram channels, up to two cardiac signals of mechanical origin as well as a respiratory signal. In this paper, an approach combining multimodal rhythmicity estimation and machine learning is presented. Using standard short-time autocorrelation and robust beat-to-beat interval estimation, the signal's self-similarity is analyzed. In particular, beat intervals as well as quality measures are derived which are further quantified using basic mathematical operations (min, mean, max, etc). Moreover, methods from the realm of image processing, 2D Fourier transformation combined with principal component analysis, are employed for dimensionality reduction. Several machine learning approaches are evaluated including linear discriminant analysis and random forest. Using an alarm-independent reduction strategy, an overall false alarm reduction with a score of 65.52 in terms of the real-time scoring system of the challenge is achieved on a hidden dataset. Employing an alarm-specific strategy, an overall real-time score of 78.20 at a true positive rate of 95% and a true negative rate of 78% is achieved. While the results for some categories still need improvement, false alarms for extreme tachycardia are suppressed with 100% sensitivity and specificity.

  16. Putative involvement of the nitrergic system on the consolidation, but not initiation, of behavioral sensitization after conspecific alarm substance in zebrafish.

    PubMed

    Lima, Monica Gomes; Silva, Suéllen de Nazaré Dos Santos; Silva, Rhayra Xavier do Carmo; Oliveira, Karen Renata Herculano Matos; Batista, Evander de Jesus Oliveira; Maximino, Caio; Herculano, Anderson Manoel

    2015-12-01

    Stressful manipulations can sensitize the behavior of an organism, increasing anxiety-like behavior after a delay; this long-term stress sensitization can represent the pathophysiological basis of trauma- and stress-related disorders (TRSDs), of which the most prevalent is post-traumatic stress disorder (PTSD). A role for the glutamate-nitric oxide pathway in this sensitization is implied by behavioral, neurophysiological and genomic data on different species. Here, we report on the long-term sensitization of anxiety-like behavior in zebrafish and the possible participation of nitric oxide in this process. Zebrafish exposed to a conspecific alarm substance (AS) show increased anxiety-like behavior at least 24h after stimulus delivery. Blocking nitric oxide synthesis with l-NAME (5mg/kg) 30min, but not 90min, after AS exposure blocks the sensitization of scototaxis and risk assessment, while treatment 90min after exposure blocks the sensitization of thigmotaxis and erratic swimming; l-NAME was not effective when administered 30min before AS exposure. These data suggest a participation of nitric oxide in the consolidation, but not in the initiation, of behavioral sensitization after predator threat.

  17. Bed-exit alarms. A component (but only a component) of fall prevention.

    PubMed

    2004-05-01

    Patient falls are a common cause of morbidity, nonfatal injuries, and trauma-related hospitalizations in the United States. Sometimes, they're even fatal. Falls typically occur either while the patient is getting into or out of bed or shortly after the patient has exited the bed. One means of helping to reduce the number of patient falls is the bed-exit alarm. Such alarms can be either built-in devices incorporated into the beds themselves or stand-alone units consisting of a portable control unit and a pressure- or position-sensitive sensor. They can serve as an "early warning system" alerting nursing staff when patients attempt to leave their beds unassisted. However, bed-exit alarms do not themselves prevent falls--a fact that is not always clearly understood. To be effective, they need to be implemented with care and with a clear understanding of their limitations. In this article, we describe the types of stand-alone bed-exit alarms currently available on the market and provide guidance to facilities on how to implement them effectively. We also review the elements of an effective fall-prevention program and recount one hospital's success in reducing patient falls. We are in the process of conducting a comparative evaluation of a number of bed-exit alarms, which will be published in an upcoming issue of Health Devices.

  18. The control, monitor, and alarm system for the ICT equipment of the ASTRI SST-2M telescope prototype for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Gianotti, Fulvio; Fioretti, Valentina; Tanci, Claudio; Conforti, Vito; Tacchini, Alessandro; Leto, Giuseppe; Gallozzi, Stefano; Bulgarelli, Andrea; Trifoglio, Massimo; Malaguti, Giuseppe; Zoli, Andrea

    2014-07-01

    ASTRI is an Italian flagship project whose first goal is the realization of an end-to-end telescope prototype, named ASTRI SST-2M, for the Cherenkov Telescope Array (CTA). The prototype will be installed in Italy during Fall 2014. A second goal will be the realization of the ASTRI/CTA mini-array which will be composed of seven SST-2M telescopes placed at the CTA Southern Site. The Information and Communication Technology (ICT) equipment necessary to drive the infrastructure for the ASTRI SST-2M prototype is being designed as a complete and stand-alone computer center. The design goal is to obtain basic ICT equipment that might be scaled, with a low level of redundancy, for the ASTRI/CTA mini-array, taking into account the necessary control, monitor and alarm system requirements. The ICT equipment envisaged at the Serra La Nave observing station in Italy, where the ASTRI SST-2M telescope prototype will operate, includes computers, servers and workstations, network devices, an uninterruptable power supply system, and air conditioning systems. Suitable hardware and software tools will allow the parameters related to the behavior and health of each item of equipment to be controlled and monitored. This paper presents the proposed architecture and technical solutions that integrate the ICT equipment in the framework of the Observatory Control System package of the ASTRI/CTA Mini- Array Software System, MASS, to allow their local and remote control and monitoring. An end-toend test case using an Internet Protocol thermometer is reported in detail.

  19. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...

  20. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...

  1. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...

  2. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...

  3. 46 CFR 153.438 - Cargo pressure or temperature alarms required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Cargo pressure or temperature alarms required. 153.438... Equipment Cargo Temperature Control Systems § 153.438 Cargo pressure or temperature alarms required. (a... vapor pressure described in § 153.371(b); or (2) An alarm that operates when the cargo's...

  4. 46 CFR 169.732 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 169.732 Section... SCHOOL VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.732 Carbon dioxide and clean agent alarms. (a) Each carbon dioxide or clean agent fire extinguishing alarm must...

  5. Changes in Default Alarm Settings and Standard In-Service are Insufficient to Improve Alarm Fatigue in an Intensive Care Unit: A Pilot Project

    PubMed Central

    Gomez, Tiffany Michelle; Tarriela, Albert Fajardo; Reed, Charles Calhoun; Paper, Bruce Michael

    2016-01-01

    Background Clinical alarm systems safety is a national concern, specifically in intensive care units (ICUs) where alarm rates are known to be the highest. Interventional projects that examined the effect of changing default alarm settings on overall alarm rate and on clinicians’ attitudes and practices toward clinical alarms and alarm fatigue are scarce. Objective To examine if (1) a change in default alarm settings of the cardiac monitors and (2) in-service nursing education on cardiac monitor use in an ICU would result in reducing alarm rate and in improving nurses’ attitudes and practices toward clinical alarms. Methods This quality improvement project took place in a 20-bed transplant/cardiac ICU with a total of 39 nurses. We implemented a unit-wide change of default alarm settings involving 17 parameters of the cardiac monitors. All nurses received an in-service education on monitor use. Alarm data were collected from the audit log of the cardiac monitors 10 weeks before and 10 weeks after the change in monitors’ parameters. Nurses’ attitudes and practices toward clinical alarms were measured using the Healthcare Technology Foundation National Clinical Alarms Survey, pre- and postintervention. Results Alarm rate was 87.86 alarms/patient day (a total of 64,500 alarms) at the preintervention period compared to 59.18 alarms/patient day (49,319 alarms) postintervention (P=.01). At baseline, Arterial Blood Pressure (ABP), Pair Premature Ventricular Contractions (PVCs), and Peripheral Capillary Oxygen Saturation (SpO2) alarms were the highest. ABP and SpO2 alarms remained among the top three at the postproject period. Out of the 39 ICU nurses, 24 (62%) provided complete pre- and postproject survey questionnaires. Compared to the preintervention survey, no remarkable changes in the postproject period were reported in nurses’ attitudes. Themes in the narrative data were related to poor usability of cardiac monitors and the frequent alarms. The data showed

  6. Spitzer Telemetry Processing System

    NASA Technical Reports Server (NTRS)

    Stanboli, Alice; Martinez, Elmain M.; McAuley, James M.

    2013-01-01

    The Spitzer Telemetry Processing System (SirtfTlmProc) was designed to address objectives of JPL's Multi-mission Image Processing Lab (MIPL) in processing spacecraft telemetry and distributing the resulting data to the science community. To minimize costs and maximize operability, the software design focused on automated error recovery, performance, and information management. The system processes telemetry from the Spitzer spacecraft and delivers Level 0 products to the Spitzer Science Center. SirtfTlmProc is a unique system with automated error notification and recovery, with a real-time continuous service that can go quiescent after periods of inactivity. The software can process 2 GB of telemetry and deliver Level 0 science products to the end user in four hours. It provides analysis tools so the operator can manage the system and troubleshoot problems. It automates telemetry processing in order to reduce staffing costs.

  7. Evaluation of the concrete shield compositions from the 2010 criticality accident alarm system benchmark experiments at the CEA Valduc SILENE facility

    SciTech Connect

    Miller, Thomas Martin; Celik, Cihangir; Dunn, Michael E; Wagner, John C; McMahan, Kimberly L; Authier, Nicolas; Jacquet, Xavier; Rousseau, Guillaume; Wolff, Herve; Savanier, Laurence; Baclet, Nathalie; Lee, Yi-kang; Trama, Jean-Christophe; Masse, Veronique; Gagnier, Emmanuel; Naury, Sylvie; Blanc-Tranchant, Patrick; Hunter, Richard; Kim, Soon; Dulik, George Michael; Reynolds, Kevin H.

    2015-01-01

    In October 2010, a series of benchmark experiments were conducted at the French Commissariat a l'Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the United States Department of Energy Nuclear Criticality Safety Program and the CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems. This series of experiments consisted of three single-pulsed experiments with the SILENE reactor. For the first experiment, the reactor was bare (unshielded), whereas in the second and third experiments, it was shielded by lead and polyethylene, respectively. The polyethylene shield of the third experiment had a cadmium liner on its internal and external surfaces, which vertically was located near the fuel region of SILENE. During each experiment, several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor. Nearly half of the foils and TLDs had additional high-density magnetite concrete, high-density barite concrete, standard concrete, and/or BoroBond shields. CEA Saclay provided all the concrete, and the US Y-12 National Security Complex provided the BoroBond. Measurement data from the experiments were published at the 2011 International Conference on Nuclear Criticality (ICNC 2011) and the 2013 Nuclear Criticality Safety Division (NCSD 2013) topical meeting. Preliminary computational results for the first experiment were presented in the ICNC 2011 paper, which showed poor agreement between the computational results and the measured values of the foils shielded by concrete. Recently the hydrogen content, boron content, and density of these concrete shields were further investigated within the constraints of the previously available data. New computational results for the first experiment are now available that

  8. Gunshot acoustic signature specific features and false alarms reduction

    NASA Astrophysics Data System (ADS)

    Donzier, Alain; Millet, Joel

    2005-05-01

    This paper provides a detailed analysis of the most specific parameters of gunshot signatures through models as well as through real data. The models for the different contributions to gunshot typical signature (shock and muzzle blast) are presented and used to discuss the variation of measured signatures over the different environmental conditions and shot configurations. The analysis is followed by a description of the performance requirements for gunshot detection systems, from sniper detection that was the main concern 10 years ago, to the new and more challenging conditions faced in today operations. The work presented examines the process of how systems are deployed and used as well as how the operational environment has changed. The main sources of false alarms and new threats such as RPGs and mortars that acoustic gunshot detection systems have to face today are also defined and discussed. Finally, different strategies for reducing false alarms are proposed based on the acoustic signatures. Different strategies are presented through various examples of specific missions ranging from vehicle protection to area protection. These strategies not only include recommendation on how to handle acoustic information for the best efficiency of the acoustic detector but also recommends some add-on sensors to enhance system overall performance.

  9. Process evaluation distributed system

    NASA Technical Reports Server (NTRS)

    Moffatt, Christopher L. (Inventor)

    2006-01-01

    The distributed system includes a database server, an administration module, a process evaluation module, and a data display module. The administration module is in communication with the database server for providing observation criteria information to the database server. The process evaluation module is in communication with the database server for obtaining the observation criteria information from the database server and collecting process data based on the observation criteria information. The process evaluation module utilizes a personal digital assistant (PDA). A data display module in communication with the database server, including a website for viewing collected process data in a desired metrics form, the data display module also for providing desired editing and modification of the collected process data. The connectivity established by the database server to the administration module, the process evaluation module, and the data display module, minimizes the requirement for manual input of the collected process data.

  10. Analysis of constant false alarm rate sidelobe canceller criterion

    NASA Astrophysics Data System (ADS)

    Reed, I. S.; Brennan, L. E.

    1985-05-01

    In this final report, the constant false alarm rate (CFAR) detection criterion for a sidelobe canceller (SLC) system, introduced in the last quarterly progress report, is found completely and analyzed. This new detection test for radar exhibits the desirable CFAR property that its probability of a false alarm (PFA) is functionally independent of the covariance of the actual noise field encountered. As a consequence, such a CFAR SLC system is ideally suited to cope with the newly evolving smart jammer threat to radar. An important objective, set in the last quarterly progress report, was to find both the false alarm and signal detection probabilities of this test. The first and most important of these two goals has been met. The probability of a false alarm (or PFA) of this CFAR SLC detection criterion is derived in closed form in this report. The success in finding the PFA is due primarily to the use of a generalization of Cochran's theorem.

  11. Indicator system for a process plant control complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1993-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  12. Laser material processing system

    DOEpatents

    Dantus, Marcos

    2015-04-28

    A laser material processing system and method are provided. A further aspect of the present invention employs a laser for micromachining. In another aspect of the present invention, the system uses a hollow waveguide. In another aspect of the present invention, a laser beam pulse is given broad bandwidth for workpiece modification.

  13. Image Processing System

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Mallinckrodt Institute of Radiology (MIR) is using a digital image processing system which employs NASA-developed technology. MIR's computer system is the largest radiology system in the world. It is used in diagnostic imaging. Blood vessels are injected with x-ray dye, and the images which are produced indicate whether arteries are hardened or blocked. A computer program developed by Jet Propulsion Laboratory known as Mini-VICAR/IBIS was supplied to MIR by COSMIC. The program provides the basis for developing the computer imaging routines for data processing, contrast enhancement and picture display.

  14. Male rats respond to their own alarm pheromone.

    PubMed

    Inagaki, Hideaki; Kiyokawa, Yasushi; Takeuchi, Yukari; Mori, Yuji

    2012-01-01

    Pheromones are defined as substances released from an individual (donor) that influence a second individual (recipient) of the same species. However, it is unclear whether mammalian pheromones can affect the donor itself. To address this question, the effect of self-exposure to an alarm pheromone was examined. Exposure to the alarm pheromone resulted in an enhanced anxiety response, which was not different between recipients that perceived their own pheromone and those that perceived another individual's pheromone. The present results suggest that the alarm pheromone influences the emotional system of the recipient as well as induces similar anxiogenic effects on the donor rat that released the alarm pheromone. This is the first evidence demonstrating the effectiveness of mammalian pheromone self-exposure.

  15. Wireless intelligent alarm technology with pyroelectric infrared sensor

    NASA Astrophysics Data System (ADS)

    Chen, Xiao

    2009-07-01

    Aiming at the defects of monitoring conducted by man in the conventional practice, we study the passive intelligent automatic alarm technology based on the pyroelectric infrared sensor and wireless communication technology. The designed passive infrared wireless alarm is composed of pyroelectric infrared sensors, infrared special chip BISS0001 and their peripheral circuits. When someone enters into the detecting and monitoring range, the alarm will detect the infrared ray of the human radiation by the contactless form and detect the signals of circuit output. Then it translates them into low frequency signals relative with human sports speed, distance and direction, produce corresponding output signals through amplifying by the back state controller, switch on the work power of the wireless transmitting circuit and make it emit the alarm signals. The system enhances the monitoring level and effects and possesses many advantages such as wide detecting range, long detecting distance and high reliability.

  16. Clutter suppression interferometry system design and processing

    NASA Astrophysics Data System (ADS)

    Knight, Chad; Deming, Ross; Gunther, Jake

    2015-05-01

    Clutter suppression interferometry (CSI) has received extensive attention due to its multi-modal capability to detect slow-moving targets, and concurrently form high-resolution synthetic aperture radar (SAR) images from the same data. The ability to continuously augment SAR images with geo-located ground moving target indicators (GMTI) provides valuable real-time situational awareness that is important for many applications. CSI can be accomplished with minimal hardware and processing resources. This makes CSI a natural candidate for applications where size, weight and power (SWaP) are constrained, such as unmanned aerial vehicles (UAVs) and small satellites. This paper will discuss the theory for optimal CSI system configuration focusing on sparse time-varying transmit and receive array manifold due to SWaP considerations. The underlying signal model will be presented and discussed as well as the potential benefits that a sparse time-varying transmit receive manifold provides. The high-level processing objectives will be detailed and examined on simulated data. Then actual SAR data collected with the Space Dynamic Laboratory (SDL) FlexSAR radar system will be analyzed. The simulated data contrasted with actual SAR data helps illustrate the challenges and limitations found in practice vs. theory. A new novel approach incorporating sparse signal processing is discussed that has the potential to reduce false- alarm rates and improve detections.

  17. Transparent materials processing system

    NASA Technical Reports Server (NTRS)

    Hetherington, J. S.

    1977-01-01

    A zero gravity processing furnace system was designed that will allow acquisition of photographic or other visual information while the sample is being processed. A low temperature (30 to 400 C) test model with a flat specimen heated by quartz-halide lamps was constructed. A high temperature (400 to 1000 C) test model heated by resistance heaters, utilizing a cylindrical specimen and optics, was also built. Each of the test models is discussed in detail. Recommendations are given.

  18. The PhysioNet/Computing in Cardiology Challenge 2015: Reducing False Arrhythmia Alarms in the ICU.

    PubMed

    Clifford, Gari D; Silva, Ikaro; Moody, Benjamin; Li, Qiao; Kella, Danesh; Shahin, Abdullah; Kooistra, Tristan; Perry, Diane; Mark, Roger G

    2015-09-01

    High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 Physio-Net/Computing in Cardiology Challenge provides a set of 1,250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppression using all available signals. Each data segment was 5 minutes long (for real time analysis), ending at the time of the alarm. For retrospective analysis, we provided a further 30 seconds of data after the alarm was triggered. A collection of 750 data segments was made available for training and a set of 500 was held back for testing. Each alarm was reviewed by expert annotators, at least two of whom agreed that the alarm was either true or false. Challenge participants were invited to submit a complete, working algorithm to distinguish true from false alarms, and received a score based on their program's performance on the hidden test set. This score was based on the percentage of alarms correct, but with a penalty that weights the suppression of true alarms five times more heavily than acceptance of false alarms. We provided three example entries based on well-known, open source signal processing algorithms, to serve as a basis for comparison and as a starting point for participants to develop their own code. A total of 38 teams submitted a total of 215 entries in this year's Challenge.

  19. Priority coding for control room alarms

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    Indicating the priority of a spatially fixed, activated alarm tile on an alarm tile array by a shape coding at the tile, and preferably using the same shape coding wherever the same alarm condition is indicated elsewhere in the control room. The status of an alarm tile can change automatically or by operator acknowledgement, but tones and/or flashing cues continue to provide status information to the operator.

  20. Quartz resonator processing system

    DOEpatents

    Peters, Roswell D. M.

    1983-01-01

    Disclosed is a single chamber ultra-high vacuum processing system for the oduction of hermetically sealed quartz resonators wherein electrode metallization and sealing are carried out along with cleaning and bake-out without any air exposure between the processing steps. The system includes a common vacuum chamber in which is located a rotatable wheel-like member which is adapted to move a plurality of individual component sets of a flat pack resonator unit past discretely located processing stations in said chamber whereupon electrode deposition takes place followed by the placement of ceramic covers over a frame containing a resonator element and then to a sealing stage where a pair of hydraulic rams including heating elements effect a metallized bonding of the covers to the frame.

  1. Sun-glint false alarm mitigation in a maritime scenario

    NASA Astrophysics Data System (ADS)

    Rossi, Alessandro; Riccobono, Aldo; Landini, Stefano

    2014-10-01

    Airborne hyperspectral imaging can be exploited to detect anomalous objects in the maritime scenario. Due to the objects high contrast with respect to the sea surface, detection can be easily accomplished by means of local anomaly detectors, such as the well-known Reed-Xiaoli (RX) algorithm. During the development of a real-time system for the detection of anomalous pixels, it has been noticed that the performance of detection is deeply affected by the presence of sun-glint. The reflection on the sea surface of the solar radiation produces a high density of alarms, that makes challenging the task of detecting the objects of interest. In this paper, it is introduced a strategy aimed at discriminating the sun-glint false alarms from the effective alarms related to targets of potential interest. False alarms due to glint are mitigated performing a local spatio-spectral analysis on each alarm furnished by the anomaly detector. The technique has been tested on hyperspectral images collected during a measurement campaign carried out near Pisa, Italy. The Selex ES SIMGA hyperspectral sensor was mounted on board of an airplane to collect high spectral resolution images in both the VNIR and SWIR spectral channels. Several experiments were carried out, setting up scenarios with small man-made objects deployed on the sea surface, so as to simulate search and rescue operations. The results have highlighted the effectiveness of the proposed solution in terms of mitigation of false alarms due to sun-glints on the maritime scenario.

  2. 21 CFR 876.2040 - Enuresis alarm.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Enuresis alarm. 876.2040 Section 876.2040 Food and... GASTROENTEROLOGY-UROLOGY DEVICES Monitoring Devices § 876.2040 Enuresis alarm. (a) Identification. An enuresis... type of device includes conditioned response enuresis alarms. (b) Classification. Class II...

  3. Log processing systems

    SciTech Connect

    Bowlin, W.P.; Kneer, M.P.; Ballance, J.D.

    1989-11-07

    This patent describes an improvement in a computer controlled processing system for lumber production. It comprises: a computer, a sequence of processing stations for processing a log segment including; an excess material removing station for generating opposed flat side surfaces on the log segment. The flat side surfaces determined by the computer to become sides of boards to be severed from the log segments; a profiling station for forming profiled edges above and below the flat side surfaces to become the side edges of the boards to be severed from the log segment, and a severing station for severing the boards from the log segments, a conveyance means establishing a path of conveyance and having continuous control of the log segment on conveying the log segment along the path and through the above defined sequence of processing stations.

  4. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  5. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  6. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  7. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  8. 21 CFR 870.1025 - Arrhythmia detector and alarm (including ST-segment measurement and alarm).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arrhythmia detector and alarm (including ST... Diagnostic Devices § 870.1025 Arrhythmia detector and alarm (including ST-segment measurement and alarm). (a) Identification. The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to...

  9. Secure Reliable Processing Systems

    DTIC Science & Technology

    1984-02-21

    specification successfully executed by application processes, technique draws from both the techniques of abstract data 121 Communications February 1980 of...J. and Farber. David A. "A \\lod’l for Verification of Data Security in Operating Systems." Communications of the ACM. Vol.21. No.9. September 1978. pp...the data being communicated exists in dleanext form as it is passed from one encrypted link to the next by the switch. Therefore the software in the

  10. Soft real-time alarm messages for ATLAS TDAQ

    NASA Astrophysics Data System (ADS)

    Darlea, G.; Al Shabibi, A.; Martin, B.; Lehmann Miotto, G.

    2010-05-01

    The ATLAS TDAQ network consists of three separate Ethernet-based networks (Data, Control and Management) with over 2000 end-nodes. The TDAQ system has to be aware of the meaningful network failures and events in order for it to take effective recovery actions. The first stage of the process is implemented with Spectrum, a commercial network management tool. Spectrum detects and registers all network events, then it publishes the information via a CORBA programming interface. A gateway program (called NSG—Network Service Gateway) connects to Spectrum through CORBA and exposes to its clients a Java RMI interface. This interface implements a callback mechanism that allows the clients to subscribe for monitoring "interesting" parts of the network. The last stage of the TDAQ network monitoring tool is implemented in a module named DNC (DAQ to Network Connection), which filters the events that are to be reported to the TDAQ system: it subscribes to the gateway only for the machines that are currently active in the system and it forwards only the alarms that are considered important for the current TDAQ data taking session. The network information is then synthesized and presented in a human-readable format. These messages can be further processed either by the shifter who is in charge, the network expert or the Online Expert System. This article aims to describe the different mechanisms of the chain that transports the network events to the front-end user, as well as the constraints and rules that govern the filtering and the final format of the alarm messages.

  11. Alarm sensor apparatus for closures

    DOEpatents

    Carlson, J.A.; Stoddard, L.M.

    1984-01-31

    An alarm sensor apparatus for closures such as doors and windows, and particularly for closures having loose tolerances such as overhead doors, garage doors or the like, the sensor apparatus comprising a pair of cooperating bracket members, one being attached to the door facing or framework and the other to the door member, two magnetic sensor elements carried by said bracket members, the bracket members comprising a pair of cooperating orthogonal guide slots and plates and a stop member engageable with one of the sensors for aligning the sensors with respect to each other in all three orthogonal planes when the door is closed.

  12. Alarm sensor apparatus for closures

    DOEpatents

    Carlson, James A.; Stoddard, Lawrence M.

    1986-01-01

    An alarm sensor apparatus for closures such as doors and windows, and particularly for closures having loose tolerances such as overhead doors, garage doors or the like, the sensor apparatus comprising a pair of cooperating bracket members, one being attached to the door facing or frame work and the other to the door member, two magnetic sensor elements carried by said bracket members, the bracket members comprising a pair of cooperating orthogonal guide slots and plates and a stop member engageable with one of the sensors for aligning the sensors with respect to each other in all three orthogonal planes when the door is closed.

  13. Calculation of the false alarm in pure frequency detection due to zero crossings of a narrow-band process - The possibility of estimating its autocorrelation envelope

    NASA Astrophysics Data System (ADS)

    Hay, J.

    Consideration is given to problems of pure frequency detection in the magnetic recording of acoustic noise in the presence of zero crossings by sinusoidal reference waves and narrow-band random processes. The principle of the partial detection of a sine wave based on isochronous zero crossings near a given coherent sequence threshold is reviewed, and a track detection criterion is introduced. A model of the signal detection process is then presented based on a probabilistic description of zero crossings which permits the definition of the normalized duration of a coherent sequence of zero crossings, and the model is validated in an experimental study of a narrow band process centered at 3240 Hz. The probability of the simultaneous detection of two channels is also calculated. The application of the model to parasitic detection in a two-frequency code is considered. Attention is then given to the relation between the isochronism of the coherent sequences of zero crossings and spectral sharpness, and a means for the direct estimation of the autocorrelation envelope of the narrowband noise process is derived.

  14. Alarm toe switch. [Patent application

    DOEpatents

    Ganyard, F.P.

    1980-11-18

    An alarm toe switch inserted within a shoe for energizing an alarm circuit in a covert manner includes an insole mounting pad into which a miniature reed switch is fixedly molded. An elongated slot perpendicular to the reed switch is formed in the bottom surface of the mounting pad. A permanent cylindrical magnet positioned in the forward portion of the slot with a diameter greater than the pad thickness causes a bump above the pad. A foam rubber block is also positioned in the slot rearwardly of the magnet and holds the magnet in normal inoperative relation. A non-magnetic support plate covers the slot and holds the magnet and foam rubber in the slot. The plate minimizes bending and frictional forces to improve movement of the magnet for reliable switch activation. The bump occupies the knuckle space beneath the big toe. When the big toe is scrunched rearwardly the magnet is moved within the slot relative to the reed switch, thus magnetically activating the switch. When toe pressure is released the foam rubber block forces the magnet back into normal inoperative position to deactivate the reed switch.

  15. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm and means of escape. 108.445 Section 108.445 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems §...

  16. 46 CFR 108.445 - Alarm and means of escape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm and means of escape. 108.445 Section 108.445 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems §...

  17. Mars Aqueous Processing System

    NASA Technical Reports Server (NTRS)

    Berggren, Mark; Wilson, Cherie; Carrera, Stacy; Rose, Heather; Muscatello, Anthony; Kilgore, James; Zubrin, Robert

    2012-01-01

    The goal of the Mars Aqueous Processing System (MAPS) is to establish a flexible process that generates multiple products that are useful for human habitation. Selectively extracting useful components into an aqueous solution, and then sequentially recovering individual constituents, can obtain a suite of refined or semi-refined products. Similarities in the bulk composition (although not necessarily of the mineralogy) of Martian and Lunar soils potentially make MAPS widely applicable. Similar process steps can be conducted on both Mars and Lunar soils while tailoring the reaction extents and recoveries to the specifics of each location. The MAPS closed-loop process selectively extracts, and then recovers, constituents from soils using acids and bases. The emphasis on Mars involves the production of useful materials such as iron, silica, alumina, magnesia, and concrete with recovery of oxygen as a byproduct. On the Moon, similar chemistry is applied with emphasis on oxygen production. This innovation has been demonstrated to produce high-grade materials, such as metallic iron, aluminum oxide, magnesium oxide, and calcium oxide, from lunar and Martian soil simulants. Most of the target products exhibited purities of 80 to 90 percent or more, allowing direct use for many potential applications. Up to one-fourth of the feed soil mass was converted to metal, metal oxide, and oxygen products. The soil residue contained elevated silica content, allowing for potential additional refining and extraction for recovery of materials needed for photovoltaic, semiconductor, and glass applications. A high-grade iron oxide concentrate derived from lunar soil simulant was used to produce a metallic iron component using a novel, combined hydrogen reduction/metal sintering technique. The part was subsequently machined and found to be structurally sound. The behavior of the lunar-simulant-derived iron product was very similar to that produced using the same methods on a Michigan iron

  18. Panic, Suffocation False Alarms, Separation Anxiety and Endogenous Opioids

    PubMed Central

    Preter, Maurice; Klein, Donald F.

    2008-01-01

    This review paper presents an amplification of the suffocation false alarm theory (SFA) of spontaneous panic (Klein, 1993). SFA postulates the existence of an evolved physiologic suffocation alarm system that monitors information about potential suffocation. Panic attacks maladaptively occur when the alarm is erroneously triggered. That panic is distinct from Cannon’s emergency fear response and Selye’s General Alarm Syndrome is shown by the prominence of intense air hunger during these attacks. Further, panic sufferers have chronic sighing abnormalities outside of the acute attack. Another basic physiologic distinction between fear and panic is the counter-intuitive lack of hypothalamic-pituitary-adrenal (HPA) activation in panic. Understanding panic as provoked by indicators of potential suffocation, such as fluctuations in pCO2 and brain lactate, as well as environmental circumstances fits the observed respiratory abnormalities. However, that sudden loss, bereavement and childhood separation anxiety are also antecedents of “spontaneous” panic requires an integrative explanation. Because of the opioid system’s central regulatory role in both disordered breathing and separation distress, we detail the role of opioidergic dysfunction in decreasing the suffocation alarm threshold. We present results from our laboratory where the naloxone-lactate challenge in normals produces supportive evidence for the endorphinergic defect hypothesis in the form of a distress episode of specific tidal volume hyperventilation paralleling challenge-produced and clinical panic. PMID:17765379

  19. Systematic review of physiologic monitor alarm characteristics and pragmatic interventions to reduce alarm frequency

    PubMed Central

    Paine, Christine Weirich; Goel, Veena V.; Ely, Elizabeth; Stave, Christopher D.; Stemler, Shannon; Zander, Miriam; Bonafide, Christopher P.

    2016-01-01

    Background Alarm fatigue from frequent nonactionable physiologic monitor alarms is frequently named as a threat to patient safety. Purpose To critically examine the available literature relevant to alarm fatigue. Data Sources Articles published in English, Spanish, or French between January 1980 and April 2015 indexed in PubMed, CINAHL, Scopus, Cochrane Library, Google Scholar, and ClinicalTrials.gov. Study Selection Articles focused on hospital physiologic monitor alarms addressing any of the following: 1) the proportion of alarms that are actionable, 2) the relationship between alarm exposure and nurse response time, and 3) the effectiveness of interventions in reducing alarm frequency. Data Extraction We extracted data on setting, collection methods, proportion of alarms determined to be actionable, nurse response time, and associations between interventions and alarm rates. Data Synthesis Our search produced 24 observational studies focused on alarm characteristics and response time and 8 studies evaluating interventions. Actionable alarm proportion ranged from <1% to 36% across a range of hospital settings. Two studies showed relationships between high alarm exposure and longer nurse response time. Most intervention studies included multiple components implemented simultaneously. While studies varied widely, and many had high risk of bias, promising but still unproven interventions include widening alarm parameters, instituting alarm delays, and using disposable electrocardiographic wires or frequently changed electrocardiographic electrodes. Conclusions Physiologic monitor alarms are commonly nonactionable, and evidence supporting the concept of alarm fatigue is emerging. Several interventions have the potential to reduce alarms safely, but more rigorously designed studies with attention to possible unintended consequences are needed. PMID:26663904

  20. The "suffocation alarm" theory of panic attacks: a critical commentary.

    PubMed

    Ley, R

    1994-12-01

    In 1993 Klein proposed a "false suffocation alarm" theory of panic attacks, claiming that many spontaneous panic attacks are due to a "suffocation monitor" in the brain erroneously signaling a lack of useful air, and triggering an evolved "suffocation alarm system". He proposed that carbon dioxide acts as a panic stimulus because rising arterial CO2 suggests suffocation may be imminent." The present paper provides a critical analysis of Klein's theory and concludes that there is neither empirical evidence nor compelling argument to support the assumptions or the proposed neurological mechanism of a "suffocation alarm", true or false, or a CO2 "suffocation monitor." Data relevant to the role of breathing in the phenomenon of panic can be parsimoniously subsumed within the domain of dyspnea.

  1. LLE'S high-pressure DT-fill process control system

    SciTech Connect

    Duffy, T.; Shmayda, W. T.; Janezic, R.; Loucks, S. J.; Reid, J.

    2008-07-15

    The OMEGA laser at the Univ. of Rochester's Laboratory for Laser Energetics (UR/LLE) implodes fusion targets that contain cryogenic solid deuterium-tritium (DT) ice layers. These ICF targets are fabricated in a high-pressure DT-fill process. This paper describes the integration and control of this DT-fill process. The appropriate safety-control response during the DT-fill process depends on the location of the tritium inventory and where the containment alarm is detected. A control response that is deemed appropriate earlier in the fill process could be a dangerous action at a later point in the fill process. The control system must adapt as the DT inventory moves through the process train. This is achieved by defining eight 'fill states' in the fill process. The control system transitions to the appropriate fill state as the DT fill progresses. The fill state reflects the tritium location, pressure, and temperature. Steps are taken to ensure that the tritium location and the fill state are in agreement. The control system monitors the containment system's integrity and will take the appropriate action, based on the tritium location and the type of containment failure. This approach not only ensures process safety, but also maximizes the productivity by executing process pauses (in lieu of aborts) when conditions allow. (authors)

  2. LLE's High-Pressure DT-Fill Process Control System

    SciTech Connect

    Duffy, T.; Shmayda, W.T.; Janezic, R.; Loucks, S.J.; Reid, J.

    2008-07-18

    The OMEGA Laser at the University of Rochester's Laboratory for Laser Energetics (UR/LLE) implodes fusion targets that contain cryogenic solid deuterium-tritium (DT) ice layers. These ICF targets are fabricated in a high-pressure DT-fill process. This paper describes the integration and control of this DT-fill process. The appropriate safety-control response during the DT-fill process depends on the location of the tritium inventory and where the containment alarm is detected. A control response that is deemed appropriate earlier in the fill process could be a dangerous action at a later point in the fill process. The control system must adapt as the DT inventory moves through the process train. This is achieved by defining eight "fill states" in the fill process. The control system transitions to the appropriate fill state as the DT fill progesses. The fill state reflects the tritium location, pressure, and temperature. Steps are taken to ensure that the tritium location and the fill state are in agreement. The control system monitors the containment system's integrity and will take the appropriate action, based on the tritium location and the type of containment failure. This approach not only ensures process safety, but also maximizes the productivity by executing process pauses (in lieu of aborts) when conditions allow.

  3. Multi-parameter vital sign database to assist in alarm optimization for general care units.

    PubMed

    Welch, James; Kanter, Benjamin; Skora, Brooke; McCombie, Scott; Henry, Isaac; McCombie, Devin; Kennedy, Rosemary; Soller, Babs

    2016-12-01

    Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective of this study was the development of a methodology to help care teams optimize alarm settings. An on-body wireless monitoring system was used to continually assess heart rate, respiratory rate, SpO2 and noninvasive blood pressure in the general ward of ten hospitals between April 1, 2014 and January 19, 2015. These data, 94,575 h for 3430 patients are contained in a large database, accessible with cloud computing tools. Simulation scenarios assessed the total alarm rate as a function of threshold and annunciation delay (s). The total alarm rate of ten alarms/patient/day predicted from the cloud-hosted database was the same as the total alarm rate for a 10 day evaluation (1550 h for 36 patients) in an independent hospital. Plots of vital sign distributions in the cloud-hosted database were similar to other large databases published by different authors. The cloud-hosted database can be used to run simulations for various alarm thresholds and annunciation delays to predict the total alarm burden experienced by nursing staff. This methodology might, in the future, be used to help reduce alarm fatigue without sacrificing the ability to continually monitor all vital signs.

  4. Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus)

    PubMed Central

    Deng, Huaiqing; Gao, Kai; Zhou, Jiang

    2016-01-01

    Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002–2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7–10 min) followed by longer variable-frequency mobbing calls lasting 5–12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520–1000 Hz and 690–3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates’ species. The system of vocal alarm behavior described in this critically endangered species is simple and effective. PMID:27686623

  5. Non-specific alarm calls trigger mobbing behavior in Hainan gibbons (Nomascus hainanus).

    PubMed

    Deng, Huaiqing; Gao, Kai; Zhou, Jiang

    2016-09-30

    Alarm calls are important defensive behaviors. Here, we report the acoustic spectrum characteristics of alarm calls produced by Hainan gibbons (Nomascus hainanus) inhabiting Bawangling National Nature Reserve in Hainan, China. Analysis of call data collected from 2002-2014 shows that alarm calls are emitted by all family group members, except infants. Alarm behavior included simple short alarming calls (7-10 min) followed by longer variable-frequency mobbing calls lasting 5-12 min. The duration of individual alarming and mobbing calls was 0.078 ± 0.014 s and 0.154 ± 0.041 s at frequency ranges of 520-1000 Hz and 690-3920 Hz, respectively. Alarming call duration was positively associated with group size. The alarm calls can trigger mobbing behavior in Hainan gibbons; this is a defense way of social animals, and first report among the primates' species. The system of vocal alarm behavior described in this critically endangered species is simple and effective.

  6. Improved television signal processing system

    NASA Technical Reports Server (NTRS)

    Wong, R. Y.

    1967-01-01

    Digital system processes spacecraft television pictures by converting images sensed on a photostorage vidicon to pulses which can be transmitted by telemetry. This system can be applied in the processing of medical X ray photographs and in electron microscopy.

  7. The Lighthouse Alarm and Locator trial - a pilot study.

    PubMed

    Melander-Wikman, A; Jansson, M; Hallberg, J; Mörtberg, C; Gard, G

    2007-01-01

    An important factor for health is the possibility to be active and mobile. To make this possible various kinds of support are needed. Integrating geographical information systems technology and user experiences is important in the development of more user-friendly positioning devices. The Lighthouse Alarm and Locator trial aimed to test a new mobile alarm system with additional functionality such as positioning and monitoring of vital signs which can be used regardless of location (in hospital, at home). The system was tested by elderly persons from a pensioner organisation and home care personnel answered up on the alarms. After the tests qualitative interviews were performed with the two groups. The results showed that their experiences of the new mobile alarm system could be described in three main categories: to be supervised, to feel safe and to be mobile. These categories formed a theme: Positioning - an ethical dilemma. The clients' mobility was perceived to increase. The personnel did not think that positioning was ethical but the clients (elderly) did.

  8. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  9. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if... exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to...

  10. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if... exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to...

  11. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if... exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to...

  12. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2640 Portable... the electrical leakage current between any two points of an electrical system and to sound an alarm if... exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to...

  13. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  14. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  15. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  16. 46 CFR 34.15-30 - Alarms-T/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS FIREFIGHTING EQUIPMENT Carbon Dioxide Extinguishing...) which are protected by a carbon dioxide extinguishing system and are normally accessible to persons on... the carbon dioxide is admitted to the space. The alarm shall be conspicuously and centrally...

  17. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... powered from: (i) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed...

  18. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... equipped or designed for future installation of a roof-mounted evaporative cooler or other equipment...) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed for use with a...

  19. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... powered from: (i) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed...

  20. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... powered from: (i) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed...

  1. 24 CFR 3280.208 - Smoke alarm requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... when a home is equipped or designed for future installation of a roof-mounted evaporative cooler or... powered from: (i) The electrical system of the home as the primary power source and a battery as a secondary power source; or (ii) A battery rated for a 10-year life, provided the smoke alarm is listed...

  2. SAR processing using SHARC signal processing systems

    NASA Astrophysics Data System (ADS)

    Huxtable, Barton D.; Jackson, Christopher R.; Skaron, Steve A.

    1998-09-01

    Synthetic aperture radar (SAR) is uniquely suited to help solve the Search and Rescue problem since it can be utilized either day or night and through both dense fog or thick cloud cover. Other papers in this session, and in this session in 1997, describe the various SAR image processing algorithms that are being developed and evaluated within the Search and Rescue Program. All of these approaches to using SAR data require substantial amounts of digital signal processing: for the SAR image formation, and possibly for the subsequent image processing. In recognition of the demanding processing that will be required for an operational Search and Rescue Data Processing System (SARDPS), NASA/Goddard Space Flight Center and NASA/Stennis Space Center are conducting a technology demonstration utilizing SHARC multi-chip modules from Boeing to perform SAR image formation processing.

  3. Display-And-Alarm Circuit For Accelerometer

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1995-01-01

    Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.

  4. T-Farm complex alarm upgrades

    SciTech Connect

    Roberts, J.B.

    1995-01-01

    The alarm and controls associated with the T, TX, and TY farms are located in the 242-T control room. The design data for replacement and upgrades of the alarm panels is in this document. This task was canceled previous to the 90% design review point.

  5. Residential smoke alarms and fire escape plans.

    PubMed Central

    Harvey, P A; Sacks, J J; Ryan, G W; Bender, P F

    1998-01-01

    OBJECTIVE: To estimate the proportion of U.S. homes with installed smoke alarms, smoke alarms on the same floor as occupants' bedrooms, and fire escape plans. METHODS: The authors analyzed data on smoke alarm use and fire escape planning from a 1994 stratified random telephone survey of 5238 U.S. households. RESULTS: Respondents from 91% of surveyed households reported the presence of at least one installed smoke alarm, and 94% of respondents reported having an alarm on the same level of the home as their sleeping area. The prevalence of installed smoke alarms varied by highest education level in the household and income level. Sixty percent of all households had designed or discussed a fire escape plan at least once; only 17% of these households had actually practiced one. CONCLUSIONS: Although overall use of smoke alarms was high, certain population subgroups were less likely to have smoke alarms or to have them installed on the same floor as bedrooms. Fire escape planning, another important safety measure, was somewhat less common, and very few respondents reported having practiced a fire escape plan with the members of their household. PMID:9769771

  6. Estimation of a Constant False Alarm Rate Processing Loss for a High-Resolution Maritime Radar System

    DTIC Science & Technology

    2008-08-01

    Radar Division (EWRD) of DSTO and BAE Australia are undertaking further software development to the Ship Air Defence Model (SADM) Modelling and...undertaking further software development to the Ship Air Defence Model (SADM) Modelling and Simulation Tool. One of the aims of this development is...of spatially uncorrelated non-Rayleigh clutter plus noise mixture for Pd = 0.5 and Pfa = 10-6 . CAL , dB GOL , dB OSL , dB 2N=16 2N=32 2N=16 2N

  7. 46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using carbon dioxide or clean agent complying with 46...

  8. 46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using carbon dioxide or clean agent complying with 46...

  9. 46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using carbon dioxide or clean agent complying with 46...

  10. DHS Regional Reachback: Rapid Expert Radiation Alarm Assistance.

    SciTech Connect

    Bowerman,B.; Archer, D.; Young, J.; Monetti, M.; Savage, B.

    2008-07-13

    Following assessments that attacks with radiological and nuclear weapons are possible, detection system deployments are being supported at national and local levels. Detection systems include both, highly sensitive but non-discriminating detectors, as well as detectors and algorithms capable of distinguishing and identifying gamma rays by energy. The latter systems, usually handheld systems based on sodium iodide detectors, also provide analysis of the specific radionuclides present and are referred to as radioisotope identifiers (RIIDs). Studies have shown that sodium iodide based RIIDs fall far short of 100% accurate identifications. The U.S. Department of Homeland Security (DHS) initiated the Regional Reachback (RRB) Program in 2006 to provide rapid expert interpretation of gamma spectroscopic data from radiation alarms from detection systems deployed by state and local authorities. With expert specialists on call 24/7, RRB provides an avenue for local and state authorities to verify routine results, interpret unknown identifications, and notify national response assets if needed. This paper will provide details of the RRE3 program, an outline of the analysis process, a description of the drills and training systems used to maintain specialists response performance, and examples of drills and incidents from the first full year of operation.

  11. Design of portable valuables touch alarm circuit

    NASA Astrophysics Data System (ADS)

    Li, Biqing; Li, Zhao

    2017-03-01

    In this paper, the name of the alarm is portable touch burglar alarm. It not only has the advantages of high sensitivity, small size and light weight, but it is easy on the trigger, the circuit is simple and easy to be implemented, besides, it works stably. This alarm is featured with simple design, convenient use, strong flexibility and reliable performance, thus it can be installed on the door or window and even can be carried on human's body. When the human body touches the metal valuables that need to be protected, the device will start the alarm equipment so as to make the bell keep ringing, and the alarm sound stops until the power is cut off.

  12. Central waste processing system

    NASA Technical Reports Server (NTRS)

    Kester, F. L.

    1973-01-01

    A new concept for processing spacecraft type wastes has been evaluated. The feasibility of reacting various waste materials with steam at temperatures of 538 - 760 C in both a continuous and batch reactor with residence times from 3 to 60 seconds has been established. Essentially complete gasification is achieved. Product gases are primarily hydrogen, carbon dioxide, methane, and carbon monoxide. Water soluble synthetic wastes are readily processed in a continuous tubular reactor at concentrations up to 20 weight percent. The batch reactor is able to process wet and dry wastes at steam to waste weight ratios from 2 to 20. Feces, urine, and synthetic wastes have been successfully processed in the batch reactor.

  13. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Audible and visual alarms. 154.1365 Section 154.1365... Instrumentation § 154.1365 Audible and visual alarms. (a) Each audible alarm must have an arrangement that allows... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only...

  14. Alarming features: birds use specific acoustic properties to identify heterospecific alarm calls

    PubMed Central

    Fallow, Pamela M.; Pitcher, Benjamin J.; Magrath, Robert D.

    2013-01-01

    Vertebrates that eavesdrop on heterospecific alarm calls must distinguish alarms from sounds that can safely be ignored, but the mechanisms for identifying heterospecific alarm calls are poorly understood. While vertebrates learn to identify heterospecific alarms through experience, some can also respond to unfamiliar alarm calls that are acoustically similar to conspecific alarm calls. We used synthetic calls to test the role of specific acoustic properties in alarm call identification by superb fairy-wrens, Malurus cyaneus. Individuals fled more often in response to synthetic calls with peak frequencies closer to those of conspecific calls, even if other acoustic features were dissimilar to that of fairy-wren calls. Further, they then spent more time in cover following calls that had both peak frequencies and frequency modulation rates closer to natural fairy-wren means. Thus, fairy-wrens use similarity in specific acoustic properties to identify alarms and adjust a two-stage antipredator response. Our study reveals how birds respond to heterospecific alarm calls without experience, and, together with previous work using playback of natural calls, shows that both acoustic similarity and learning are important for interspecific eavesdropping. More generally, this study reconciles contrasting views on the importance of alarm signal structure and learning in recognition of heterospecific alarms. PMID:23303539

  15. The chemistry of eavesdropping, alarm, and deceit.

    PubMed Central

    Stowe, M K; Turlings, T C; Loughrin, J H; Lewis, W J; Tumlinson, J H

    1995-01-01

    Arthropods that prey on or parasitize other arthropods frequently employ those chemical cues that reliably indicate the presence of their prey or hosts. Eavesdropping on the sex pheromone signals emitted to attract mates allows many predators and parasitoids to find and attack adult insects. The sex pheromones are also useful signals for egg parasitoids since eggs are frequently deposited on nearby plants soon after mating. When the larval stages of insects or other arthropods are the targets, a different foraging strategy is employed. The larvae are often chemically inconspicuous, but when they feed on plants the injured plants respond by producing and releasing defensive chemicals. These plant chemicals may also serve as "alarm signals" that are exploited by predators and parasitoids to locate their victims. There is considerable evidence that the volatile "alarm signals" are induced by interactions of substances from the herbivore with the damaged plant tissue. A very different strategy is employed by several groups of spiders that remain stationary and send out chemical signals that attract prey. Some of these spiders prey exclusively on male moths. They attract the males by emitting chemicals identical to the sex pheromones emitted by female moths. These few examples indicate the diversity of foraging strategies of arthropod predators and parasitoids. It is likely that many other interesting chemically mediated interactions between arthropod hunters and their victims remain to be discovered. Increased understanding of these systems will enable us to capitalize on natural interactions to develop more ecologically sound, environmentally safe methods for biological control of insect pests of agriculture. PMID:7816823

  16. The PhysioNet/Computing in Cardiology Challenge 2015: Reducing False Arrhythmia Alarms in the ICU

    PubMed Central

    Clifford, Gari D; Silva, Ikaro; Moody, Benjamin; Li, Qiao; Kella, Danesh; Shahin, Abdullah; Kooistra, Tristan; Perry, Diane; Mark, Roger G.

    2016-01-01

    High false alarm rates in the ICU decrease quality of care by slowing staff response times while increasing patient delirium through noise pollution. The 2015 Physio-Net/Computing in Cardiology Challenge provides a set of 1,250 multi-parameter ICU data segments associated with critical arrhythmia alarms, and challenges the general research community to address the issue of false alarm suppression using all available signals. Each data segment was 5 minutes long (for real time analysis), ending at the time of the alarm. For retrospective analysis, we provided a further 30 seconds of data after the alarm was triggered. A collection of 750 data segments was made available for training and a set of 500 was held back for testing. Each alarm was reviewed by expert annotators, at least two of whom agreed that the alarm was either true or false. Challenge participants were invited to submit a complete, working algorithm to distinguish true from false alarms, and received a score based on their program’s performance on the hidden test set. This score was based on the percentage of alarms correct, but with a penalty that weights the suppression of true alarms five times more heavily than acceptance of false alarms. We provided three example entries based on well-known, open source signal processing algorithms, to serve as a basis for comparison and as a starting point for participants to develop their own code. A total of 38 teams submitted a total of 215 entries in this year’s Challenge. PMID:27331073

  17. Design of Sensor Data Processing Steps in an Air Pollution Monitoring System

    PubMed Central

    Jung, Young Jin; Lee, Yang Koo; Lee, Dong Gyu; Lee, Yongmi; Nittel, Silvia; Beard, Kate; Nam, Kwang Woo; Ryu, Keun Ho

    2011-01-01

    Environmental monitoring is required to understand the effects of various kinds of phenomena such as a flood, a typhoon, or a forest fire. To detect the environmental conditions in remote places, monitoring applications employ the sensor networks to detect conditions, context models to understand phenomena, and computing technology to process the large volumes of data. In this paper, we present an air pollution monitoring system to provide alarm messages about potentially dangerous areas with sensor data analysis. We design the data analysis steps to understand the detected air pollution regions and levels. The analyzed data is used to track the pollution and to give an alarm. This implemented monitoring system is used to mitigate the damages caused by air pollution. PMID:22247663

  18. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  19. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  20. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  1. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  2. 46 CFR 78.47-13 - Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., and smoke detecting alarm bells. 78.47-13 Section 78.47-13 Shipping COAST GUARD, DEPARTMENT OF.... § 78.47-13 Fire detecting and manual alarm, automatic sprinkler, and smoke detecting alarm bells. (a) The fire detecting and manual alarm automatic sprinklers, and smoke detecting alarm bells in...

  3. Secure Reliable Processing Systems

    DTIC Science & Technology

    1981-07-01

    UCLA-ENG-7854), August 1978. Popek, G.J. and D.A. Farber. "A Model for Verification of Data Security in Operating Systems," Communications of the ACM...via covert channels is a data security problem. On the other hand, the unauthorized use of the system to communicate is a confinement problem. The...point here is that if there exists a communication channel, it may be accidentally used by a user and information leaked. For a system to be data secure

  4. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Access to the bilge alarm must require the breaking of a seal, except when— (1) Re-zeroing the instrument...) Each bilge alarm must activate its alarm whenever clean water is used for cleaning or zeroing...

  5. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Access to the bilge alarm must require the breaking of a seal, except when— (1) Re-zeroing the instrument...) Each bilge alarm must activate its alarm whenever clean water is used for cleaning or zeroing...

  6. NORSAR Detection Processing System.

    DTIC Science & Technology

    1987-05-31

    systems have been reliable. NTA/Lillestrom and Hamar will take a new initiative medio April regarding 04C. The line will be remeasured and if a certain...estimate of the ambient noise level at the site of the FINESA array, ground motion spectra were calculated for four time intervals. Two intervals were

  7. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20... there is no off position. (5) Automation alarms must be separate and independent of the following:...

  8. 46 CFR 62.25-20 - Instrumentation, alarms, and centralized stations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-20... there is no off position. (5) Automation alarms must be separate and independent of the following:...

  9. Digital TV processing system

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Two digital video data compression systems directly applicable to the Space Shuttle TV Communication System were described: (1) For the uplink, a low rate monochrome data compressor is used. The compression is achieved by using a motion detection technique in the Hadamard domain. To transform the variable source rate into a fixed rate, an adaptive rate buffer is provided. (2) For the downlink, a color data compressor is considered. The compression is achieved first by intra-color transformation of the original signal vector, into a vector which has lower information entropy. Then two-dimensional data compression techniques are applied to the Hadamard transformed components of this last vector. Mathematical models and data reliability analyses were also provided for the above video data compression techniques transmitted over a channel encoded Gaussian channel. It was shown that substantial gains can be achieved by the combination of video source and channel coding.

  10. Controlling misses and false alarms in a machine learning framework for predicting uniformity of printed pages

    NASA Astrophysics Data System (ADS)

    Nguyen, Minh Q.; Allebach, Jan P.

    2015-01-01

    In our previous work1 , we presented a block-based technique to analyze printed page uniformity both visually and metrically. The features learned from the models were then employed in a Support Vector Machine (SVM) framework to classify the pages into one of the two categories of acceptable and unacceptable quality. In this paper, we introduce a set of tools for machine learning in the assessment of printed page uniformity. This work is primarily targeted to the printing industry, specifically the ubiquitous laser, electrophotographic printer. We use features that are well-correlated with the rankings of expert observers to develop a novel machine learning framework that allows one to achieve the minimum "false alarm" rate, subject to a chosen "miss" rate. Surprisingly, most of the research that has been conducted on machine learning does not consider this framework. During the process of developing a new product, test engineers will print hundreds of test pages, which can be scanned and then analyzed by an autonomous algorithm. Among these pages, most may be of acceptable quality. The objective is to find the ones that are not. These will provide critically important information to systems designers, regarding issues that need to be addressed in improving the printer design. A "miss" is defined to be a page that is not of acceptable quality to an expert observer that the prediction algorithm declares to be a "pass". Misses are a serious problem, since they represent problems that will not be seen by the systems designers. On the other hand, "false alarms" correspond to pages that an expert observer would declare to be of acceptable quality, but which are flagged by the prediction algorithm as "fails". In a typical printer testing and development scenario, such pages would be examined by an expert, and found to be of acceptable quality after all. "False alarm" pages result in extra pages to be examined by expert observers, which increases labor cost. But "false

  11. [The performance of respirator alarms during simulated critical events in CMV/IPPV artificial respiration].

    PubMed

    Bender, H J; Frankenberger, H; Ryll, C; Albrecht, M D

    1993-06-01

    Alarm systems of ventilators enhance detection of possible critical events during artificial ventilation. Due to their significance, in some countries the alarm detection of ventilators is regulated by federal law. Up to now, no recommendations for the adjustment of alarm limits exist and only a few detailed investigations of the accuracy of alarm detection are available. METHODS. The response of four commercially available ventilators (Servoventilator 900C, Siemens, Inc.; Bennett 7200a, Hoyer, Inc.; Veolar, Hamilton, Inc.; EVITA, Dräger, Inc.) to critical events during artificial ventilation of a test lung were evaluated. We measured the alarm time (the time between event creation and alarm response) of ten different simulated critical events including disconnection, differentisized leaks, failure of the gas supply, and obstruction at different places in the artificial airway. DISCUSSION. All respirators were able to recognise severe critical situations such as hose disconnection, failure of gas supply, and total airway obstruction within a short time (< 15 s). The recognition of small airway leaks was more difficult for the ventilators even when the alarm thresholds were close. The alarm detection of the EVITA (software 10.0 or less) under conditions of partial airway obstruction may be a source of risk for the patient as the machine continued supplying inspiration with pressure-limited ventilation even when the pressure threshold was reached.

  12. Giving radioiodine? Think about airport security alarms.

    PubMed

    Kaniuka-Jakubowska, S; Lewczuk, A; Mizan-Gross, K; Obołończyk, L; Lass, P; Sworczak, K

    2012-01-01

    An increased sensitivity of airport detectors, a growing number of isotopic tests, and globalization of the society have raised a number of false positive radioactive alarms at airports and public places. This paper presents two new cases of patients who triggered airport security alarms after receiving 740MBq of (131)I for non-toxic goitre and attempts to compare surprisingly limited literature concerning this problem. A 57-year-old man triggered a security alarm at three different airports on the 17th, 28th, and 31st day after radioiodine exposure. Interestingly enough, in the meantime, on the 18th and 22nd day, no radiation was detected in him at the airport where he was twice detained as a source of radiation later on. The second case presents a 45-year-old woman who activated security alarm detectors while crossing a border on her coach trip 28 days after radioiodine administration.

  13. A radar unattended ground sensor with micro-Doppler capabilities for false alarm reduction

    NASA Astrophysics Data System (ADS)

    Tahmoush, Dave; Silvious, Jerry; Burke, Ed

    2010-10-01

    Unattended ground sensors (UGS) provide the capability to inexpensively secure remote borders and other areas of interest. However, the presence of normal animal activity can often trigger a false alarm. Accurately detecting humans and distinguishing them from natural fauna is an important issue in security applications to reduce false alarm rates and improve the probability of detection. In particular, it is important to detect and classify people who are moving in remote locations and transmit back detections and analysis over extended periods at a low cost and with minimal maintenance. We developed and demonstrate a compact radar technology that is scalable to a variety of ultra-lightweight and low-power platforms for wide area persistent surveillance as an unattended, unmanned, and man-portable ground sensor. The radar uses micro-Doppler processing to characterize the tracks of moving targets and to then eliminate unimportant detections due to animals as well as characterize the activity of human detections. False alarms from sensors are a major liability that hinders widespread use. Incorporating rudimentary intelligence into sensors can reduce false alarms but can also result in a reduced probability of detection. Allowing an initial classification that can be updated with new observations and tracked over time provides a more robust framework for false alarm reduction at the cost of additional sensor observations. This paper explores these tradeoffs with a small radar sensor for border security. Multiple measurements were done to try to characterize the micro-Doppler of human versus animal and vehicular motion across a range of activities. Measurements were taken at the multiple sites with realistic but low levels of clutter. Animals move with a quadrupedal motion, which can be distinguished from the bipedal human motion. The micro-Doppler of a vehicle with rotating parts is also shown, along with ground truth images. Comparisons show large variations for

  14. Conspecific injury raises an alarm in medaka

    PubMed Central

    Mathuru, Ajay S.

    2016-01-01

    In the late 1930s, Karl von Frisch reported that semiochemicals released upon injury, act as alarm substances (Schreckstoff) in fish. In Ostariophysi species, club cells in the epidermis are believed to contain cues related to alarm substance; however, the function of club cells, primarily as reservoirs of alarm substance has been debated. Here, I describe an alarm response in the Japanese rice fish Oryzias latipes (medaka), a member of the order Beloniformes. The response to alarm substance (Schreckreaction) in medaka is characterized by bouts of immobility and an increase in cortisol levels within minutes of exposure to conspecific skin extract. Histological analysis, however, suggests that club cells are either rare or absent in the medaka epidermis. In addition to describing an uncharacterized behavior in a vertebrate popular for genetic and developmental studies, these results support the hypothesis that the primary function of epidermal club cells may be unrelated to a role as alarm substance cells. The existence of similar behavioral responses in two evolutionarily distant but well established laboratory models, the zebrafish and the medaka, offers the possibility of comparative analyses of neural circuits encoding innate fear. PMID:27824153

  15. The nature of alarm communication in Constrictotermes cyphergaster (Blattodea: Termitoidea: Termitidae): the integration of chemical and vibroacoustic signals

    PubMed Central

    Cristaldo, Paulo F.; Jandák, Vojtĕch; Kutalová, Kateřina; Rodrigues, Vinícius B.; Brothánek, Marek; Jiříček, Ondřej; DeSouza, Og; Šobotník, Jan

    2015-01-01

    ABSTRACT Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae), confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S)-α-pinene and myrcene, along with a minor component, (E)-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards) resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant) increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through vibratory

  16. The nature of alarm communication in Constrictotermes cyphergaster (Blattodea: Termitoidea: Termitidae): the integration of chemical and vibroacoustic signals.

    PubMed

    Cristaldo, Paulo F; Jandák, Vojtĕch; Kutalová, Kateřina; Rodrigues, Vinícius B; Brothánek, Marek; Jiříček, Ondřej; DeSouza, Og; Šobotník, Jan

    2015-11-04

    Alarm signalling is of paramount importance to communication in all social insects. In termites, vibroacoustic and chemical alarm signalling are bound to operate synergistically but have never been studied simultaneously in a single species. Here, we inspected the functional significance of both communication channels in Constrictotermes cyphergaster (Termitidae: Nasutitermitinae), confirming the hypothesis that these are not exclusive, but rather complementary processes. In natural situations, the alarm predominantly attracts soldiers, which actively search for the source of a disturbance. Laboratory testing revealed that the frontal gland of soldiers produces a rich mixture of terpenoid compounds including an alarm pheromone. Extensive testing led to identification of the alarm pheromone being composed of abundant monoterpene hydrocarbons (1S)-α-pinene and myrcene, along with a minor component, (E)-β-ocimene. The vibratory alarm signalling consists of vibratory movements evidenced as bursts; a series of beats produced predominantly by soldiers. Exposing termite groups to various mixtures containing the alarm pheromone (crushed soldier heads, frontal gland extracts, mixture of all monoterpenes, and the alarm pheromone mixture made of standards) resulted in significantly higher activity in the tested groups and also increased intensity of the vibratory alarm communication, with the responses clearly dose-dependent. Lower doses of the pheromone provoked higher numbers of vibratory signals compared to higher doses. Higher doses induced long-term running of all termites without stops necessary to perform vibratory behaviour. Surprisingly, even crushed worker heads led to low (but significant) increases in the alarm responses, suggesting that other unknown compound in the worker's head is perceived and answered by termites. Our results demonstrate the existence of different alarm levels in termites, with lower levels being communicated through vibratory signals, and

  17. The Process of Systemic Change

    ERIC Educational Resources Information Center

    Duffy, Francis M.; Reigeluth, Charles M.; Solomon, Monica; Caine, Geoffrey; Carr-Chellman, Alison A.; Almeida, Luis; Frick, Theodore; Thompson, Kenneth; Koh, Joyce; Ryan, Christopher D.; DeMars, Shane

    2006-01-01

    This paper presents several brief papers about the process of systemic change. These are: (1) Step-Up-To-Excellence: A Protocol for Navigating Whole-System Change in School Districts by Francis M. Duffy; (2) The Guidance System for Transforming Education by Charles M. Reigeluth; (3) The Schlechty Center For Leadership In School Reform by Monica…

  18. A new Wellsite Information System to aid the drilling process

    SciTech Connect

    Grenadier, J.A.; McCann, D.; Koch, S.; Schlumberger, A.

    1994-12-31

    The IDEAL Wellsite Information System acquires data to monitor the drilling process. It interprets the realtime data flow from both surface and downhole and displays useful information on high resolution color screens to the key decision makers on and off the wellsite. The IDEAL Wellsite Information System can support four classes of users simultaneously: The driller, the directional driller on the rig floor, logging specialists in the unit and the company representative in the customer`s office. Color displays have been customized to the specialized needs of each class of user. In particular, the IDEAL Driller`s Display is a pressurized unit located on the rig floor. The driller can select from a number of screens with a minimum number of keystrokes. This information network improves drilling efficiency, geological evaluation and subsequent production through enhanced geological steering. Data is continually stored in both the time and depth domains. These databases can be exported into a variety of formats. Data can also be transmitted in realtime to the customer`s office offsite. Backup system components allow for redundancy so that system downtime is virtually eliminated. By having system developers concentrate on making the workstation easy to operate, the users can focus on the drilling process and not on the computer system. Custom graphic displays were designed by drillers for drillers. {open_quotes}Smart Alarms{close_quotes} have been designed to alert the user of potential problems such as kicks, sticking pipe and drillpipe washout.

  19. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only after the fault that actuated it is corrected. (c) Each visual alarm must be marked to show the type and, except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must...

  20. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only after the fault that actuated it is corrected. (c) Each visual alarm must be marked to show the type and, except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must...

  1. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only after the fault that actuated it is corrected. (c) Each visual alarm must be marked to show the type and, except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must...

  2. 46 CFR 154.1365 - Audible and visual alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... alarm's actuation by other faults. (b) Each visual alarm must be one that can be turned off only after the fault that actuated it is corrected. (c) Each visual alarm must be marked to show the type and, except for remote group alarms, the location of each fault that actuates it. (d) Each vessel must...

  3. 46 CFR 97.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE...

  4. 46 CFR 78.47-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping... and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” (b)...

  5. 46 CFR 108.627 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED” next...

  6. 46 CFR 78.47-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping... and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED.” (b)...

  7. 46 CFR 196.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE...

  8. 46 CFR 196.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE...

  9. 46 CFR 97.37-9 - Carbon dioxide alarm.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE...

  10. 46 CFR 108.627 - Carbon dioxide alarm.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 108.627 Section 108.627 Shipping... EQUIPMENT Equipment Markings and Instructions § 108.627 Carbon dioxide alarm. Each carbon dioxide alarm must be identified by marking: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED” next...

  11. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Bilge alarm: Design specification. 162.050-33 Section....050-33 Bilge alarm: Design specification. (a) This section contains requirements that apply to bilge alarms. (b) Each bilge alarm must be designed to meet the requirements for an oil content meter in §...

  12. 46 CFR 162.050-33 - Bilge alarm: Design specification.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Bilge alarm: Design specification. 162.050-33 Section....050-33 Bilge alarm: Design specification. (a) This section contains requirements that apply to bilge alarms. (b) Each bilge alarm must be designed to meet the requirements for an oil content meter in §...

  13. National Fire Codes. A Compilation of NFPA Codes, Standards, Recommended Practices, and Manuals. Volume 7: Alarm and Special Extinguishing Systems. 1969-70.

    ERIC Educational Resources Information Center

    National Fire Protection Association, Boston, MA.

    These NFPA recommendations are phrased in terms of performance or objectives, the intent being to permit the utilization of any methods, devices, or materials which will produce the desired results. The major topics included are--(1) extinguishing systems, (2) standpipe and hose systems, (3) wetting agents, (4) fire hydrants, (5) water charges for…

  14. Low Voltage Alarm Apprenticeship. Related Training Modules. 7.1-26.10 Alarm Basics.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This packet of 70 learning modules on alarm basics is 1 of 8 such packets developed for apprenticeship training for low voltage alarm. Introductory materials are a complete listing of all available modules and a supplementary reference list. Each module contains some or all of these components: goal, performance indicators, study guide (a check…

  15. Low Voltage Alarm Apprenticeship. Related Training Modules. 0.1 History of Alarms.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This packet of one learning module on the history of alarms is one of eight such packets developed for apprenticeship training for low voltage alarm. Introductory materials are a complete listing of all available modules and a supplementary reference list. Each module contains some or all of these components: goal, performance indicators, study…

  16. Surveillance of industrial processes with correlated parameters

    DOEpatents

    White, Andrew M.; Gross, Kenny C.; Kubic, William L.; Wigeland, Roald A.

    1996-01-01

    A system and method for surveillance of an industrial process. The system and method includes a plurality of sensors monitoring industrial process parameters, devices to convert the sensed data to computer compatible information and a computer which executes computer software directed to analyzing the sensor data to discern statistically reliable alarm conditions. The computer software is executed to remove serial correlation information and then calculate Mahalanobis distribution data to carry out a probability ratio test to determine alarm conditions.

  17. Surveillance of industrial processes with correlated parameters

    DOEpatents

    White, A.M.; Gross, K.C.; Kubic, W.L.; Wigeland, R.A.

    1996-12-17

    A system and method for surveillance of an industrial process are disclosed. The system and method includes a plurality of sensors monitoring industrial process parameters, devices to convert the sensed data to computer compatible information and a computer which executes computer software directed to analyzing the sensor data to discern statistically reliable alarm conditions. The computer software is executed to remove serial correlation information and then calculate Mahalanobis distribution data to carry out a probability ratio test to determine alarm conditions. 10 figs.

  18. Intelligent Work Process Engineering System

    NASA Technical Reports Server (NTRS)

    Williams, Kent E.

    2003-01-01

    Optimizing performance on work activities and processes requires metrics of performance for management to monitor and analyze in order to support further improvements in efficiency, effectiveness, safety, reliability and cost. Information systems are therefore required to assist management in making timely, informed decisions regarding these work processes and activities. Currently information systems regarding Space Shuttle maintenance and servicing do not exist to make such timely decisions. The work to be presented details a system which incorporates various automated and intelligent processes and analysis tools to capture organize and analyze work process related data, to make the necessary decisions to meet KSC organizational goals. The advantages and disadvantages of design alternatives to the development of such a system will be discussed including technologies, which would need to bedesigned, prototyped and evaluated.

  19. Epidermal ‘alarm substance’ cells of fishes maintained by non-alarm functions: possible defence against pathogens, parasites and UVB radiation

    PubMed Central

    Chivers, Douglas P; Wisenden, Brian D; Hindman, Carrie J; Michalak, Tracy A; Kusch, Robin C; Kaminskyj, Susan G.W; Jack, Kristin L; Ferrari, Maud C.O; Pollock, Robyn J; Halbgewachs, Colin F; Pollock, Michael S; Alemadi, Shireen; James, Clayton T; Savaloja, Rachel K; Goater, Cameron P; Corwin, Amber; Mirza, Reehan S; Kiesecker, Joseph M; Brown, Grant E; Adrian, James C; Krone, Patrick H; Blaustein, Andrew R; Mathis, Alicia

    2007-01-01

    Many fishes possess specialized epidermal cells that are ruptured by the teeth of predators, thus reliably indicating the presence of an actively foraging predator. Understanding the evolution of these cells has intrigued evolutionary ecologists because the release of these alarm chemicals is not voluntary. Here, we show that predation pressure does not influence alarm cell production in fishes. Alarm cell production is stimulated by exposure to skin-penetrating pathogens (water moulds: Saprolegnia ferax and Saprolegnia parasitica), skin-penetrating parasites (larval trematodes: Teleorchis sp. and Uvulifer sp.) and correlated with exposure to UV radiation. Suppression of the immune system with environmentally relevant levels of Cd inhibits alarm cell production of fishes challenged with Saprolegnia. These data are the first evidence that alarm substance cells have an immune function against ubiquitous environmental challenges to epidermal integrity. Our results indicate that these specialized cells arose and are maintained by natural selection owing to selfish benefits unrelated to predator–prey interactions. Cell contents released when these cells are damaged in predator attacks have secondarily acquired an ecological role as alarm cues because selection favours receivers to detect and respond adaptively to public information about predation. PMID:17686729

  20. The evolution of urgency-based and functionally referential alarm calls in ground-dwelling species.

    PubMed

    Furrer, Roman D; Manser, Marta B

    2009-03-01

    A major evolutionary force driving functionally referential alarm calls is the need for different strategies to escape various predator types in complex structured habitats. In contrast, a single escape strategy appears to be sufficient in less-structured open habitats, and under such conditions urgency-dependent alarm calls may be favored. Nevertheless, some species, such as meerkats (Suricata suricatta), have evolved functionally referential alarm calls despite living in open areas, using only bolt-holes for retreat. To understand the evolution of different alarm call systems, we investigated the calls of sympatric Cape ground squirrels (Xerus inauris) and compared their antipredator and foraging behavior with that of meerkats. Cape ground squirrels emitted urgency-dependent alarm calls and responded to playbacks depending on urgency, not predator type. Vigilance behavior and habitat use differed between the two species. Meerkats roam widely to find prey and for efficient foraging depend on coordinated predator vigilance and escape behavior. As herbivores with smaller territories, Cape ground squirrels depend less on coordinated antipredator behavior, and urgency-dependent alarm calls encode all essential information. We conclude that habitat complexity does not explain the evolution of functionally referential alarm calls in all species, and other constraints, such as the need to coordinate group movements to maintain foraging efficiency, could be more relevant.

  1. Advanced System for Process Engineering

    SciTech Connect

    Williams, K. E.; Saus, L. S.; Regenhardt, P. A.

    1992-02-01

    ASPEN (Advanced System for Process Engineering) is a state of the art process simulator and economic evaluation package which was designed for use in engineering fossil energy conversion processes. ASPEN can represent multiphase streams including solids, and handle complex substances such as coal. The system can perform steady state material and energy balances, determine equipment size and cost, and carry out preliminary economic evaluations. It is supported by a comprehensive physical property system for computation of major properties such as enthalpy, entropy, free energy, molar volume, equilibrium ratio, fugacity coefficient, viscosity, thermal conductivity, and diffusion coefficient for specified phase conditions; vapor, liquid, or solid. The properties may be computed for pure components, mixtures, or components in a mixture, as appropriate. The ASPEN Input Language is oriented towards process engineers.

  2. Controlled cross-over study in normal subjects of naloxone-preceding-lactate infusions; respiratory and subjective responses: relationship to endogenous opioid system, suffocation false alarm theory and childhood parental loss

    PubMed Central

    Preter, M.; Lee, S. H.; Petkova, E.; Vannucci, M.; Kim, S.; Klein, D. F.

    2015-01-01

    Background The expanded suffocation false alarm theory (SFA) hypothesizes that dysfunction in endogenous opioidergic regulation increases sensitivity to CO2, separation distress and panic attacks. In panic disorder (PD) patients, both spontaneous clinical panics and lactate-induced panics markedly increase tidal volume (TV), whereas normals have a lesser effect, possibly due to their intact endogenous opioid system. We hypothesized that impairing the opioidergic system by naloxone could make normal controls parallel PD patients' response when lactate challenged. Whether actual separations and losses during childhood (childhood parental loss, CPL) affected naloxone-induced respiratory contrasts was explored. Subjective panic-like symptoms were analyzed although pilot work indicated that the subjective aspect of anxious panic was not well modeled by this specific protocol. Method Randomized cross-over sequences of intravenous naloxone (2 mg/kg) followed by lactate (10 mg/kg), or saline followed by lactate, were given to 25 volunteers. Respiratory physiology was objectively recorded by the LifeShirt. Subjective symptomatology was also recorded. Results Impairment of the endogenous opioid system by naloxone accentuates TV and symptomatic response to lactate. This interaction is substantially lessened by CPL. Conclusions Opioidergic dysregulation may underlie respiratory pathophysiology and suffocation sensitivity in PD. Comparing specific anti-panic medications with ineffective anti-panic agents (e.g. propranolol) can test the specificity of the naloxone + lactate model. A screen for putative anti-panic agents and a new pharmacotherapeutic approach are suggested. Heuristically, the experimental unveiling of the endogenous opioid system impairing effects of CPL and separation in normal adults opens a new experimental, investigatory area. PMID:20444308

  3. Multiple pass collaborative search in the presence of false alarms

    NASA Astrophysics Data System (ADS)

    Baylog, John G.; Wettergren, Thomas A.

    2015-05-01

    This paper addresses the planning of multiple collaborative searchers that are seeking to find hidden objects (i.e. mines) in environments where the sensor detection process is prone to false alarms. In such situations it is anticipated that collaboration between searchers that are examining the same sub-regions may be used to mitigate the impact of false alarms. A standard Receiver Operator Characteristic (ROC) analysis is conducted and the mapping between a single search pass ROC curve and an equivalent multiple search pass representation within a cumulative probability space is discussed. This mapping produces an analogous family of ROC curves for an increasing number of search passes using either a first detection or multiple occurrence performance criteria. The migration of ROC operating points is analyzed as additional search passes are included within a search plan and suggests the need to coordinate search effort with operating point selection. The mapping from waiting time event probabilities to a total error performance criterion weighted according to the cumulative probabilities of missed detection and false alarm is developed. Details of its application for threshold optimization within search planning is discussed and numerical results are provided to demonstrate the usefulness of the models in evaluating performance trade-offs.

  4. Raman water vapour concentration measurements for reduction of false alarms in forest fire detection

    NASA Astrophysics Data System (ADS)

    Bellecci, C.; Gaudio, P.; Gelfusa, M.; Lo Feudo, T.; Malizia, A.; Richetta, M.; Ventura, P.

    2009-09-01

    Forest fires can be the cause of environmental catastrophe, with the natural outcomes of serious ecological and economic damages, together with the possibility to endanger human safety. At the aim to reduce this catastrophe several author have been shown that the Laser light scattering can be uses to reveals the particulate emitted in the smoke. Infact experimental and theoretical investigations have shown that lidar is a powerful tool to detect the tenuous smoke plumes produced by forest fires at an early stage. In early 90's Arbolino and Andreucci have shown the theoretical possibility to detect the particulate emitted in atmosphere from smoke forest fire. Vilar at all have shown experimentally the possibility to measure the density variation in atmosphere due to plume emitted in forest fire event. Gaudio at all. have already shown that it is possible to evaluate water vapor emitted in smoke of vegetable fuel using a CO2 dial system. In this paper a theoretical model to evaluate the capabilities of a lidar system in fire surveillance of wooded areas will be presented. In particular we intend propose a technique to minimizing the false alarm in the detection of forest fire by lidar based on a measurement of second components emitted in a combustion process. Usually to detect a fire alarm a rapid increase of aerosol amount is measured. If the backscattering signal report a peak, the presences of a forest fire will be probable. Our idea to confirm this hypothesis is measure the second components emitted in a forest fire at the aim to minimize the false alarm. The simulated measurements of the humidity amount within the smoke plume will be carried out by means of Raman analysis. Fixing the burning rate of the vegetable-fuels, the maximum range of detection will be evaluated.

  5. Parallel processing spacecraft communication system

    NASA Technical Reports Server (NTRS)

    Bolotin, Gary S. (Inventor); Donaldson, James A. (Inventor); Luong, Huy H. (Inventor); Wood, Steven H. (Inventor)

    1998-01-01

    An uplink controlling assembly speeds data processing using a special parallel codeblock technique. A correct start sequence initiates processing of a frame. Two possible start sequences can be used; and the one which is used determines whether data polarity is inverted or non-inverted. Processing continues until uncorrectable errors are found. The frame ends by intentionally sending a block with an uncorrectable error. Each of the codeblocks in the frame has a channel ID. Each channel ID can be separately processed in parallel. This obviates the problem of waiting for error correction processing. If that channel number is zero, however, it indicates that the frame of data represents a critical command only. That data is handled in a special way, independent of the software. Otherwise, the processed data further handled using special double buffering techniques to avoid problems from overrun. When overrun does occur, the system takes action to lose only the oldest data.

  6. Poison and alarm: the Asian hornet Vespa velutina uses sting venom volatiles as an alarm pheromone.

    PubMed

    Cheng, Ya-Nan; Wen, Ping; Dong, Shi-Hao; Tan, Ken; Nieh, James C

    2017-02-15

    In colonial organisms, alarm pheromones can provide a key fitness advantage by enhancing colony defence and warning of danger. Learning which species use alarm pheromone and the key compounds involved therefore enhances our understanding of how this important signal has evolved. However, our knowledge of alarm pheromones is more limited in the social wasps and hornets compared with the social bees and ants. Vespa velutina is an economically important and widespread hornet predator that attacks honey bees and humans. This species is native to Asia and has now invaded Europe. Despite growing interest in V. velutina, it was unknown whether it possessed an alarm pheromone. We show that these hornets use sting venom as an alarm pheromone. Sting venom volatiles were strongly attractive to hornet workers and triggered attacks. Two major venom fractions, consisting of monoketones and diketones, also elicited attack. We used gas chromatography coupled to electroantennographic detection (GC-EAD) to isolate 13 known and 3 unknown aliphatic ketones and alcohols in venom that elicited conspicuous hornet antennal activity. Two of the unknown compounds may be an undecen-2-one and an undecene-2,10-dinone. Three major compounds (heptan-2-one, nonan-2-one and undecan-2-one) triggered attacks, but only nonan-2-one did so at biologically relevant levels (10 hornet equivalents). Nonan-2-one thus deserves particular attention. However, the key alarm releasers for V. velutina remain to be identified. Such identification will help to illuminate the evolution and function of alarm compounds in hornets.

  7. Ultrasonic sensor system to detect solids in a milk pasteurization process

    NASA Astrophysics Data System (ADS)

    Barroeta Z., Carlos; Sanchez M., Fernando L.; Fernando R., G. Moreno; Montes P., Laura

    2002-11-01

    In the food industry, many products require a specific process. In the milk industry, the raw milk passes through several process stages before reaching the end user in a very qualitative and healthy way. One of the problems of the milk is that it can contain solids in suspension, result of contamination of the milk, or inherent to the pasteurization process itself. In order to control these solids, a solid detection system is being developed, which will detect the solids by the reflection and refraction of ultrasonic waves. The sensor must be set in the upper part of the milk containers, and with a grid array to allow the control system to prevent these solids from entering into the pipes of the processing plant. The sensing system may activate an acoustic alarm to indicate that a solid has been detected, and a visual one to indicate the affected part of the process. (To be presented in Spanish.)

  8. Advanced Information Processing System (AIPS)

    NASA Technical Reports Server (NTRS)

    Pitts, Felix L.

    1993-01-01

    Advanced Information Processing System (AIPS) is a computer systems philosophy, a set of validated hardware building blocks, and a set of validated services as embodied in system software. The goal of AIPS is to provide the knowledgebase which will allow achievement of validated fault-tolerant distributed computer system architectures, suitable for a broad range of applications, having failure probability requirements of 10E-9 at 10 hours. A background and description is given followed by program accomplishments, the current focus, applications, technology transfer, FY92 accomplishments, and funding.

  9. Peruvian Weapon System Acquisition Process

    DTIC Science & Technology

    1990-12-01

    process for a major program. The United States DOD Directive 5000.1 defines four distinct phases of the acquisition process: concept exploration , demon...Unified or Specified Command. 1. Concept Exploration Phase The first phase for a major system is the concept exploration phase. During this phase... exploration phase proreses. Premature introduction of operating and support details may have a negative effect by dosing out promising alternatives [Ref

  10. Mianserin affects alarm reaction to conspecific chemical alarm cues in Nile tilapia.

    PubMed

    Barreto, Rodrigo Egydio

    2017-02-01

    In this study, I show that mianserin, a chemical with serotonin and adrenoceptor antagonist activities, increases fish vulnerability to a potential predator threat, when prey fish must deal with this threat based on conspecific chemical alarm cues. For that, I evaluated whether mianserin, diluted in the water, influences the behavioral responses of Nile tilapia (Oreochromis niloticus) to conspecific skin extract (chemical alarm cues). I found that, while mianserin did not abolished antipredator responses, this drug mitigates some components of this defensive reaction. Thus, a potential decrease in serotonin and adrenergic activities reduces the ability of dealing with predators when perceiving conspecific chemical alarm cues.

  11. Adjustable electronic load-alarm relay

    DOEpatents

    Mason, Charles H.; Sitton, Roy S.

    1976-01-01

    This invention is an improved electronic alarm relay for monitoring the current drawn by an AC motor or other electrical load. The circuit is designed to measure the load with high accuracy and to have excellent alarm repeatability. Chattering and arcing of the relay contacts are minimal. The operator can adjust the set point easily and can re-set both the high and the low alarm points by means of one simple adjustment. The relay includes means for generating a signal voltage proportional to the motor current. In a preferred form of the invention a first operational amplifier is provided to generate a first constant reference voltage which is higher than a preselected value of the signal voltage. A second operational amplifier is provided to generate a second constant reference voltage which is lower than the aforementioned preselected value of the signal voltage. A circuit comprising a first resistor serially connected to a second resistor is connected across the outputs of the first and second amplifiers, and the junction of the two resistors is connected to the inverting terminal of the second amplifier. Means are provided to compare the aforementioned signal voltage with both the first and second reference voltages and to actuate an alarm if the signal voltage is higher than the first reference voltage or lower than the second reference voltage.

  12. 46 CFR 193.15-30 - Alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... to persons on board while the vessel is being navigated which are protected by a carbon dioxide... automatically sounded when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and... arranged as to sound during the 20-second delay period prior to the discharge of carbon dioxide into...

  13. 46 CFR 193.15-30 - Alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... to persons on board while the vessel is being navigated which are protected by a carbon dioxide... automatically sounded when the carbon dioxide is admitted to the space. The alarm shall be conspicuously and... arranged as to sound during the 20-second delay period prior to the discharge of carbon dioxide into...

  14. 46 CFR 63.15-7 - Alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... reset. (c) For steam boilers, operation of the lower low water cutoff must automatically sound an..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY BOILERS General... periodically unattended machinery space, the auxiliary boiler trip alarm required by 46 CFR 62.35-50, Table...

  15. Anatomy of a climate impact study: The alarming case of the Colorado River System Tim P. Barnett* David W. Pierce* *Scripps Inst. Oceanography, La Jolla, CA 92093 (Invited)

    NASA Astrophysics Data System (ADS)

    Barnett, T. P.; Pierce, D. W.

    2009-12-01

    Studies over the past two decades, and especially the last 3-4 years, have shown that human-induced climate change is likely to reduce the amount of water in the Colorado River System (CRS) by 10 to 30%. The region has the fastest growing population in the United States, and supports a sprawling agricultural industry based primarily on irrigation using CRS water. If climate change reduces the available water as projected, this would have a profound impact on the economy and residents of the region. But how likely is such a dire forecast to be true? What are the uncertainties associated with this main conclusion? In this talk, we lead the audience through the step by step analyses that led to the prediction. Formal detection and attribution studies, including the first regionally downscaled multivariate analysis, have confirmed that hydrological trends in the western U.S. are a consequence of anthropogenic climate change. Different sets of global climate models can be selected for future projections, but the warming and drying signal is consistent among them. When applied to a statistical water balance model of the CRS that shows excellent agreement with the U.S. Bureau of Reclamation’s full model, we find that currently projected water deliveries are simply not sustainable in the face of anthropogenic climate change. Throughout our analysis, we place special emphasis on items that could lead to uncertainties, e.g. verification of an existing anthropogenic signal in the hydrology of the west, downscaling, climate model differences associated with use of arbitrary ensembles of models, future climate prediction and statistical simulation of past, present and future river flows. We find that these uncertainties do not obviate the basic point that scheduled CRS water deliveries are unsustainable. The CRS of reservoirs, dams, and water conveyances has never fallen short of its promised water deliveries since it was constructed. The population and agricultural industry

  16. Network command processing system overview

    NASA Technical Reports Server (NTRS)

    Nam, Yon-Woo; Murphy, Lisa D.

    1993-01-01

    The Network Command Processing System (NCPS) developed for the National Aeronautics and Space Administration (NASA) Ground Network (GN) stations is a spacecraft command system utilizing a MULTIBUS I/68030 microprocessor. This system was developed and implemented at ground stations worldwide to provide a Project Operations Control Center (POCC) with command capability for support of spacecraft operations such as the LANDSAT, Shuttle, Tracking and Data Relay Satellite, and Nimbus-7. The NCPS consolidates multiple modulation schemes for supporting various manned/unmanned orbital platforms. The NCPS interacts with the POCC and a local operator to process configuration requests, generate modulated uplink sequences, and inform users of the ground command link status. This paper presents the system functional description, hardware description, and the software design.

  17. XCPU2 process management system

    SciTech Connect

    Ionkov, Latchesar; Van Hensbergen, Eric

    2009-01-01

    Xcpu2 is a new process management system that allows the users to specify custom file system for a running job. Most cluster management systems enforce single software distribution running on all nodes. Xcpu2 allows programs running on the cluster to work in environment identical to the user's desktop, using the same versions of the libraries and tools the user installed locally, and accessing the configuration file in the same places they are located on the desktop. Xcpu2 builds on our earlier work with the Xcpu system. Like Xcpu, Xcpu2's process management interface is represented as a set of files exported by a 9P file server. It supports heterogeneous clusters and multiple head nodes. Unlike Xcpu, it uses pull instead of push model. In this paper we describe the Xcpu2 clustering model, its operation and how the per-job filesystem configuration can be used to solve some of the common problems when running a cluster.

  18. Parallel processing and expert systems

    NASA Technical Reports Server (NTRS)

    Lau, Sonie; Yan, Jerry C.

    1991-01-01

    Whether it be monitoring the thermal subsystem of Space Station Freedom, or controlling the navigation of the autonomous rover on Mars, NASA missions in the 1990s cannot enjoy an increased level of autonomy without the efficient implementation of expert systems. Merely increasing the computational speed of uniprocessors may not be able to guarantee that real-time demands are met for larger systems. Speedup via parallel processing must be pursued alongside the optimization of sequential implementations. Prototypes of parallel expert systems have been built at universities and industrial laboratories in the U.S. and Japan. The state-of-the-art research in progress related to parallel execution of expert systems is surveyed. The survey discusses multiprocessors for expert systems, parallel languages for symbolic computations, and mapping expert systems to multiprocessors. Results to date indicate that the parallelism achieved for these systems is small. The main reasons are (1) the body of knowledge applicable in any given situation and the amount of computation executed by each rule firing are small, (2) dividing the problem solving process into relatively independent partitions is difficult, and (3) implementation decisions that enable expert systems to be incrementally refined hamper compile-time optimization. In order to obtain greater speedups, data parallelism and application parallelism must be exploited.

  19. Persons with Mild or Moderate Alzheimer's Disease Learn to Use Urine Alarms and Prompts to Avoid Large Urinary Accidents

    ERIC Educational Resources Information Center

    Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Bosco, Andrea; Zonno, Nadia; Badagliacca, Francesco

    2011-01-01

    This study assessed whether three patients with Alzheimer's disease could learn to use urine alarms and caregivers' prompts to eliminate large urinary accidents. As soon as the patient began to release urine, the alarm system presented auditory and vibratory signals. In relation to those signals, the caregiver would prompt/encourage the patient to…

  20. A Model of Clinical Alarm Errors in Hospital.

    PubMed

    Busch-Vishniac, Ilene

    2015-01-01

    Although there has been much attention paid recently to clinical alarms, research has primarily focused on particular aspects of the clinical alarm problem, such as how to reduce nuisance alarms. This paper takes a broad view of clinical alarms and develops a model of errors in alarm handling and how they affect patients directly. Based on reports in the literature, I estimate that alarms that should sound by current standards do not sound about 9% of the time. Additionally, about 3% of alarms that are clinically significant are ignored, either intentionally or because they were inaudible. However, these errors produce a very low rate of reported alarm-related deaths and other adverse effects (on the order of a couple adverse effects per 10 million alarm errors). While it is not yet possible to estimate the probabilities of clinical alarms having an adverse impact on patients other than the patient whose alarm is sounding, such indirect adverse effects likely occur at a low level as a result of disruption of staff workflow, creation of a noisy hospital environment, and contribution to communication difficulties. Consideration of alarms should include not only the patient connected to the device that is sounding, but also the impact of the alarm on other patients in the vicinity.

  1. Coma Patient Monitoring System Using Image Processing

    NASA Astrophysics Data System (ADS)

    Sankalp, Meenu

    2011-12-01

    COMA PATIENT MONITORING SYSTEM provides high quality healthcare services in the near future. To provide more convenient and comprehensive medical monitoring in big hospitals since it is tough job for medical personnel to monitor each patient for 24 hours.. The latest development in patient monitoring system can be used in Intensive Care Unit (ICU), Critical Care Unit (CCU), and Emergency Rooms of hospital. During treatment, the patient monitor is continuously monitoring the coma patient to transmit the important information. Also in the emergency cases, doctor are able to monitor patient condition efficiently to reduce time consumption, thus it provides more effective healthcare system. So due to importance of patient monitoring system, the continuous monitoring of the coma patient can be simplified. This paper investigates about the effects seen in the patient using "Coma Patient Monitoring System" which is a very advanced product related to physical changes in body movement of the patient and gives Warning in form of alarm and display on the LCD in less than one second time. It also passes a sms to a person sitting at the distant place if there exists any movement in any body part of the patient. The model for the system uses Keil software for the software implementation of the developed system.

  2. Lunar materials processing system integration

    NASA Technical Reports Server (NTRS)

    Sherwood, Brent

    1992-01-01

    The theme of this paper is that governmental resources will not permit the simultaneous development of all viable lunar materials processing (LMP) candidates. Choices will inevitably be made, based on the results of system integration trade studies comparing candidates to each other for high-leverage applications. It is in the best long-term interest of the LMP community to lead the selection process itself, quickly and practically. The paper is in five parts. The first part explains what systems integration means and why the specialized field of LMP needs this activity now. The second part defines the integration context for LMP -- by outlining potential lunar base functions, their interrelationships and constraints. The third part establishes perspective for prioritizing the development of LMP methods, by estimating realistic scope, scale, and timing of lunar operations. The fourth part describes the use of one type of analytical tool for gaining understanding of system interactions: the input/output model. A simple example solved with linear algebra is used to illustrate. The fifth and closing part identifies specific steps needed to refine the current ability to study lunar base system integration. Research specialists have a crucial role to play now in providing the data upon which this refinement process must be based.

  3. Advanced information processing system: Local system services

    NASA Technical Reports Server (NTRS)

    Burkhardt, Laura; Alger, Linda; Whittredge, Roy; Stasiowski, Peter

    1989-01-01

    The Advanced Information Processing System (AIPS) is a multi-computer architecture composed of hardware and software building blocks that can be configured to meet a broad range of application requirements. The hardware building blocks are fault-tolerant, general-purpose computers, fault-and damage-tolerant networks (both computer and input/output), and interfaces between the networks and the computers. The software building blocks are the major software functions: local system services, input/output, system services, inter-computer system services, and the system manager. The foundation of the local system services is an operating system with the functions required for a traditional real-time multi-tasking computer, such as task scheduling, inter-task communication, memory management, interrupt handling, and time maintenance. Resting on this foundation are the redundancy management functions necessary in a redundant computer and the status reporting functions required for an operator interface. The functional requirements, functional design and detailed specifications for all the local system services are documented.

  4. Alarm guided critical function and success path monitoring

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    The use of alarm indication on the overview (IPSO) display to initiate diagnosis of challenges to critical functions or unavailability of success paths, and further alarm-based guidance toward ultimate diagnosis.

  5. Safety vs. privacy: elderly persons' experiences of a mobile safety alarm.

    PubMed

    Melander-Wikman, Anita; Fältholm, Ylva; Gard, Gunvor

    2008-07-01

    The demographic development indicates an increased elderly population in Sweden in the future. One of the greatest challenges for a society with an ageing population is to provide high-quality health and social care. New information and communication technology and services can be used to further improve health care. To enable elderly persons to stay at home as long as possible, various kinds of technology, such as safety alarms, are used at home. The aim of this study was to describe the experiences of elderly persons through testing a mobile safety alarm and their reasoning about safety, privacy and mobility. The mobile safety alarm tested was a prototype in development. Five elderly persons with functional limitations and four healthy elderly persons from a pensioner's organisation tested the alarm. The mobile alarm with a drop sensor and a positioning device was tested for 6 weeks. This intervention was evaluated with qualitative interviews, and analysed with latent content analysis. The result showed four main categories: feeling safe, being positioned and supervised, being mobile, and reflecting on new technology. From these categories, the overarching category 'Safety and mobility are more important than privacy' emerged. The mobile safety alarm was perceived to offer an increased opportunity for mobility in terms of being more active and as an aid for self-determination. The fact that the informants were located by means of the positioning device was not experienced as violating privacy as long as they could decide how to use the alarm. It was concluded that this mobile safety alarm was experienced as a tool to be active and mobile. As a way to keep self-determination and empowerment, the individual has to make a 'cost-benefit' analysis where privacy is sacrificed to the benefit of mobility and safety. The participants were actively contributing to the development process.

  6. Japanese monkeys (Macaca fuscata) spontaneously associate alarm calls with snakes appearing in the left visual field.

    PubMed

    Shibasaki, Masahiro; Nagumo, Sumiharu; Koda, Hiroki

    2014-08-01

    Many socially living animals are sensitive to a potential predator as part of their antipredator strategy. Alarm calls function to deter predators and to help other group members detect danger. The left visual field is involved in detection of potential threats or predators in many vertebrates, but it is unclear how alarm calls influence visual detection of a potential predator. Here, we experimentally examined how alarm calls spontaneously influence the search for pictures of a potential predator in captive Japanese macaques. We used an audiovisual preferential-looking paradigm by presenting pictures of a snake and a flower simultaneous with either a recording of alarm calls or contact calls. We found no difference in gaze duration between the 2 picture types when playing back contact calls. Monkeys looked significantly longer at pictures of snakes than at those of flowers when alarm calls were played back if the snake pictures were presented on the left side of the monkey's visual field, indicating right hemispheric bias during processing of predator representations. This is the first laboratory demonstration of auditory enhancement of visual detection of predators in the left visual field in animals, which will contribute to a better understanding of alarm call studies conducted in the wild.

  7. Image processing algorithm for integrated sense and avoid systems

    NASA Astrophysics Data System (ADS)

    Forlenza, Lidia; Fasano, Giancarmine; Accardo, Domenico; Moccia, Antonio; Rispoli, Attilio

    2010-10-01

    To allow Unmanned Aircraft Systems (UAS) accessing National Airspace System (NAS) "Equivalent levels of safety" to the ones of human vision must be guaranteed. Therefore, an appropriate "Sense and Avoid" technology must be developed that is capable of detecting, tracking, and avoiding obstacles. The Department of Aerospace Engineering at University of Naples has been involved in a project funded by the Italian Aerospace Research Centre (CIRA) for the realization of a prototypical "Obstacle Detection & Identification" (ODID) System. It is installed onboard a Very Light Aircraft (VLA) and it is characterized by a hierarchical sensor configuration in which the radar is the main sensor while EO cameras are the auxiliary ones in order to increase accuracy and data rate so that anti-collision requirements are fulfilled. This paper focuses on the Image Processing algorithm for the panchromatic camera. Among the several techniques listed in literature the edge detection - labeling one resulted as the best compromise in terms of computational load, detection range, false alarm rate, miss detection rate and adaptability at different background luminosity conditions. Moreover it has been customized in order to allow for reliable operation in a wide range of flight and luminance configurations and it has been tested and run on a sequence of real images taken during flight tests. At the end, a table that summarizes those results is presented. Indeed, the output tracking measurements accuracy increases by an order of magnitude with respect to standalone radar one.

  8. Parallel processing and expert systems

    NASA Technical Reports Server (NTRS)

    Yan, Jerry C.; Lau, Sonie

    1991-01-01

    Whether it be monitoring the thermal subsystem of Space Station Freedom, or controlling the navigation of the autonomous rover on Mars, NASA missions in the 90's cannot enjoy an increased level of autonomy without the efficient use of expert systems. Merely increasing the computational speed of uniprocessors may not be able to guarantee that real time demands are met for large expert systems. Speed-up via parallel processing must be pursued alongside the optimization of sequential implementations. Prototypes of parallel expert systems have been built at universities and industrial labs in the U.S. and Japan. The state-of-the-art research in progress related to parallel execution of expert systems was surveyed. The survey is divided into three major sections: (1) multiprocessors for parallel expert systems; (2) parallel languages for symbolic computations; and (3) measurements of parallelism of expert system. Results to date indicate that the parallelism achieved for these systems is small. In order to obtain greater speed-ups, data parallelism and application parallelism must be exploited.

  9. False Alarm Reduction in BSN-Based Cardiac Monitoring Using Signal Quality and Activity Type Information

    PubMed Central

    Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa

    2015-01-01

    False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring. PMID:25671512

  10. A micro-geography of fear: learning to eavesdrop on alarm calls of neighbouring heterospecifics

    PubMed Central

    Magrath, Robert D.; Bennett, Thomas H.

    2012-01-01

    Many vertebrates eavesdrop on alarm calls of other species, which is a remarkable ability, given geographical variation in community composition and call diversity within and among species. We used micro-geographical variation in community composition to test whether individuals recognize heterospecific alarm calls by: (i) responding to acoustic features shared among alarm calls; (ii) having innate responses to particular heterospecific calls; or (iii) learning specific alarm calls. We found that superb fairy-wrens (Malurus cyaneus) fled to cover to playback of noisy miner (Manorina melanocephala) aerial predator alarm calls only in locations where miners were present, suggesting that learning rather than acoustic structure determines response. Sites with and without miners were well within the dispersal distance of fairy-wrens, and philopatric males and dispersing females showed the same pattern, so that local genetic adaptation is extremely unlikely. Furthermore, where miners were present, fairy-wrens responded appropriately to different miner calls, implying eavesdropping on their signalling system rather than fleeing from miners themselves. Learned eavesdropping on alarm calls enables individuals to harvest ecologically relevant information from heterospecifics on an astonishingly fine spatial scale. Such phenotypic plasticity is valuable in a changing world, where individuals can be exposed to new species. PMID:21849313

  11. 46 CFR 78.47-10 - Manual alarm boxes.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Manual alarm boxes. 78.47-10 Section 78.47-10 Shipping... and Emergency Equipment, Etc. § 78.47-10 Manual alarm boxes. (a) In all new installations, manual alarm boxes shall be clearly and permanently marked “IN CASE OF FIRE BREAK GLASS.” Existing boxes not...

  12. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  13. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  14. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  15. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  16. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  17. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  18. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  19. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  20. 46 CFR 97.37-50 - Ventilation alarm failure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Ventilation alarm failure. 97.37-50 Section 97.37-50... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-50 Ventilation alarm failure. (a) The alarm required by § 92.15-10(d)(4) of this subchapter, which indicates the loss of required...

  1. 46 CFR 78.47-75 - Ventilation alarm failure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Ventilation alarm failure. 78.47-75 Section 78.47-75... Fire and Emergency Equipment, Etc. § 78.47-75 Ventilation alarm failure. (a) The alarm required by § 72.15-15 (c)(4) of this subchapter, which indicates the loss of required ventilation in spaces...

  2. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  3. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  4. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  5. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  6. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  7. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  8. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  9. 21 CFR 870.1100 - Blood pressure alarm.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood...

  10. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... mixture causing actuation of the alarm is taken. (2) If the alarm has a positive displacement mixture pump... centrifugal mixture pump or is not equipped with a mixture pump, the mixture flow rate is reduced to one-half of the alarm's maximum design flow rate. After reduction of pressure or flow rate, the oil content...

  11. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... mixture causing actuation of the alarm is taken. (2) If the alarm has a positive displacement mixture pump... centrifugal mixture pump or is not equipped with a mixture pump, the mixture flow rate is reduced to one-half of the alarm's maximum design flow rate. After reduction of pressure or flow rate, the oil content...

  12. 46 CFR 162.050-35 - Bilge alarm: Approval tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... mixture causing actuation of the alarm is taken. (2) If the alarm has a positive displacement mixture pump... centrifugal mixture pump or is not equipped with a mixture pump, the mixture flow rate is reduced to one-half of the alarm's maximum design flow rate. After reduction of pressure or flow rate, the oil content...

  13. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  14. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  15. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  16. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  17. 46 CFR 78.47-5 - General alarm contact makers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false General alarm contact makers. 78.47-5 Section 78.47-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-5 General alarm contact makers. Each general alarm...

  18. 46 CFR 196.37-7 - General alarm bells.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false General alarm bells. 196.37-7 Section 196.37-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-7 General alarm bells. (a) All general alarm...

  19. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  20. 46 CFR 108.623 - General alarm bell switch.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false General alarm bell switch. 108.623 Section 108.623... AND EQUIPMENT Equipment Markings and Instructions § 108.623 General alarm bell switch. Each general alarm bell switch must be marked “GENERAL ALARM” on a plate or other firm noncorrosive backing....

  1. Multiple meter monitoring circuits served by single alarm

    NASA Technical Reports Server (NTRS)

    Bandini, U.

    1967-01-01

    Circuitry for multiple meter relay circuits provides complete isolation for each circuit served by a single alarm and permits alarm reset after an out-of-tolerance event in one relay circuit so that the remaining relay circuits continue to be alarm protected.

  2. Alarm annunciation in a graphical environment

    SciTech Connect

    Adams, D.G.

    1994-08-01

    Well-designed graphical user interfaces, such as Microsoft Windows{trademark} or UNIX{trademark} -- based X-Windows, provide a capability for enhanced display of security alarm information. Conversely, a poorly designed interface can quickly overwhelm an operator. This paper describes types of graphical information that can be displayed and offers guidance on how to best display that information. Limits are proposed for the complexity of the user interface, and guidelines are suggested for the display of maps and sensors.

  3. NDMAS System and Process Description

    SciTech Connect

    Larry Hull

    2012-10-01

    Experimental data generated by the Very High Temperature Reactor Program need to be more available to users in the form of data tables on Web pages that can be downloaded to Excel or in delimited text formats that can be used directly for input to analysis and simulation codes, statistical packages, and graphics software. One solution that can provide current and future researchers with direct access to the data they need, while complying with records management requirements, is the Nuclear Data Management and Analysis System (NDMAS). This report describes the NDMAS system and its components, defines roles and responsibilities, describes the functions the system performs, describes the internal processes the NDMAS team uses to carry out the mission, and describes the hardware and software used to meet Very High Temperature Reactor Program needs.

  4. Chemical production processes and systems

    DOEpatents

    Holladay, Johnathan E.; Muzatko, Danielle S.; White, James F.; Zacher, Alan H.

    2014-06-17

    Hydrogenolysis systems are provided that can include a reactor housing an Ru-comprising hydrogenolysis catalyst and wherein the contents of the reactor is maintained at a neutral or acidic pH. Reactant reservoirs within the system can include a polyhydric alcohol compound and a base, wherein a weight ratio of the base to the compound is less than 0.05. Systems also include the product reservoir comprising a hydrogenolyzed polyhydric alcohol compound and salts of organic acids, and wherein the moles of base are substantially equivalent to the moles of salts or organic acids. Processes are provided that can include an Ru-comprising catalyst within a mixture having a neutral or acidic pH. A weight ratio of the base to the compound can be between 0.01 and 0.05 during exposing.

  5. Chemical production processes and systems

    DOEpatents

    Holladay, Johnathan E; Muzatko, Danielle S; White, James F; Zacher, Alan H

    2015-04-21

    Hydrogenolysis systems are provided that can include a reactor housing an Ru-comprising hydrogenolysis catalyst and wherein the contents of the reactor is maintained at a neutral or acidic pH. Reactant reservoirs within the system can include a polyhydric alcohol compound and a base, wherein a weight ratio of the base to the compound is less than 0.05. Systems also include the product reservoir comprising a hydrogenolyzed polyhydric alcohol compound and salts of organic acids, and wherein the moles of base are substantially equivalent to the moles of salts or organic acids. Processes are provided that can include an Ru-comprising catalyst within a mixture having a neutral or acidic pH. A weight ratio of the base to the compound can be between 0.01 and 0.05 during exposing.

  6. Multipurpose Vacuum Induction Processing System

    NASA Astrophysics Data System (ADS)

    Govindaraju, M.; Kulkarni, Deepak; Balasubramanian, K.

    2012-11-01

    Multipurpose vacuum processing systems are cost effective; occupy less space, multiple functional under one roof and user friendly. A multipurpose vacuum induction system was designed, fabricated and installed in a record time of 6 months time at NFTDC Hyderabad. It was designed to function as a) vacuum induction melting/refining of oxygen free electronic copper/pure metals, b) vacuum induction melting furnace for ferrous materials c) vacuum induction melting for non ferrous materials d) large vacuum heat treatment chamber by resistance heating (by detachable coil and hot zone) e) bottom discharge vacuum induction melting system for non ferrous materials f) Induction heat treatment system and g) directional solidification /investment casting. It contains provision for future capacity addition. The attachments require to manufacture multiple shaped castings and continuous rod casting can be added whenever need arises. Present capacity is decided on the requirement for 10years of development path; presently it has 1.2 ton liquid copper handling capacity. It is equipped with provision for capacity addition up to 2 ton liquid copper handling capacity in future. Provision is made to carry out the capacity addition in easy steps quickly. For easy operational maintenance and troubleshooting, design was made in easily detachable sections. High vacuum system is also is detachable, independent and easily movable which is first of its kind in the country. Detailed design parameters, advantages and development history are presented in this paper.

  7. Dynamic security assessment processing system

    NASA Astrophysics Data System (ADS)

    Tang, Lei

    The architecture of dynamic security assessment processing system (DSAPS) is proposed to address online dynamic security assessment (DSA) with focus of the dissertation on low-probability, high-consequence events. DSAPS upgrades current online DSA functions and adds new functions to fit into the modern power grid. Trajectory sensitivity analysis is introduced and its applications in power system are reviewed. An index is presented to assess transient voltage dips quantitatively using trajectory sensitivities. Then the framework of anticipatory computing system (ACS) for cascading defense is presented as an important function of DSAPS. ACS addresses various security problems and the uncertainties in cascading outages. Corrective control design is automated to mitigate the system stress in cascading progressions. The corrective controls introduced in the dissertation include corrective security constrained optimal power flow, a two-stage load control for severe under-frequency conditions, and transient stability constrained optimal power flow for cascading outages. With state-of-the-art computing facilities to perform high-speed extended-term time-domain simulation and optimization for large-scale systems, DSAPS/ACS efficiently addresses online DSA for low-probability, high-consequence events, which are not addressed by today's industrial practice. Human interference is reduced in the computationally burdensome analysis.

  8. A systems process of reinforcement.

    PubMed

    Sudakov, K V

    1997-01-01

    Functional systems theory was used to consider the process of reinforcement of the actions on the body of reinforcing factors, i.e., the results of behavior satisfying the body's original needs. The systems process of reinforcement includes reverse afferentation entering the CNS from receptors acted upon by various parameters of the desired results, and mechanisms for comparing reverse afferentation with the apparatus which accepts the results of the action and the corresponding emotional component. A tight interaction between reinforcement and the dominant motivation is generated on the basis of the hologram principle. Reinforcement forms an apparatus for predicting a desired result, i.e. a result-of-action acceptor. Reinforcement procedures significant changes in the activities of individual neurons in the various brain structures involved in dominant motivation, transforming their spike activity for a burst pattern to regular discharges; there are also molecular changes in neuron properties. After preliminary reinforcement, the corresponding motivation induces the ribosomal system of neurons to start synthesizing special effector molecules, which organize molecular engrams of the acceptor of the action's result. Sensory mechanisms of reinforcement are considered, with particular reference to the information role of emotions.

  9. [The systems process of reinforcement].

    PubMed

    Sudakov, K V

    1996-01-01

    The process of reinforcement is considered in the context of the general theory of functional systems as an important part of behavioural act organization closely interacting with the dominant motivation. It is shown that reinforcement substantially changes the activities of separate neurons in different brain structures involved in dominant motivation. After a preliminary reinforcement under the influence of corresponding motivation the ribosomal apparatus of neurons begins to synthesize special molecular engrams of the action acceptor. The sensory mechanisms of reinforcement and, especially, the role of emotions are considered in details in the paper.

  10. LBTO Alarm Notification/Management and Error Diagnostic Tools

    NASA Astrophysics Data System (ADS)

    De La Peña, M. D.; Biddick, C.; Summers, K.; Summers, D.

    2015-09-01

    The Large Binocular Telescope Observatory (LBTO) Telescope Control System (TCS) is comprised of fifteen subsystems and accepts commands from the operator, as well as from six pairs of instruments. To the operator the TCS presents as a high-level set of GUIs with each GUI corresponding to one specific subsystem and providing full state information and varying degrees of control. The TCS GUIs not only provide the operators with broad control over all aspects of the telescope, but each individual GUI also reports problems within its domain through the use of color-coded messages and widgets indicating the seriousness of the issue. While there is significant problem reporting available to the operator, until recently there was no centralized and persistent visual indication or “annunciator” display for issues. In order to provide a way to present problems in a centralized and persistent fashion with “on-the-spot guidance” to ease the job of the operator and to have an acknowledge capability, the LBTO project decided to leverage an existing Alarm Handler which is a GUI client application associated with the Experimental Physics and Industrial Control System (EPICS)1. This paper briefly describes the TCS sources of problem reporting information and how the EPICS Alarm Handler supplements the current system.

  11. Real-time monitoring system for improving corona electrostatic separation in the process of recovering waste printed circuit boards.

    PubMed

    Li, Jia; Zhou, Quan; Xu, Zhenming

    2014-12-01

    Although corona electrostatic separation is successfully used in recycling waste printed circuit boards in industrial applications, there are problems that cannot be resolved completely, such as nonmetal particle aggregation and spark discharge. Both of these problems damage the process of separation and are not easy to identify during the process of separation in industrial applications. This paper provides a systematic study on a real-time monitoring system. Weight monitoring systems were established to continuously monitor the separation process. A Virtual Instrumentation program written by LabVIEW was utilized to sample and analyse the mass increment of the middling product. It includes four modules: historical data storage, steady-state analysis, data computing and alarm. Three kinds of operating conditions were used to verify the applicability of the monitoring system. It was found that the system achieved the goal of monitoring during the separation process and realized the function of real-time analysis of the received data. The system also gave comprehensible feedback on the accidents of material blockages in the feed inlet and high-voltage spark discharge. With the warning function of the alarm system, the whole monitoring system could save the human cost and help the new technology to be more easily applied in industry.

  12. TRANSIENT ACCIDENT ANALYSIS OF THE GLOVEBOX SYSTEM IN A LARGE PROCESS ROOM

    SciTech Connect

    Lee, S

    2008-01-11

    Local transient hydrogen concentrations were evaluated inside a large process room when the hydrogen gas was released by three postulated accident scenarios associated with the process tank leakage and fire leading to a loss of gas confinement. The three cases considered in this work were fire in a room, loss of confinement from a process tank, and loss of confinement coupled with fire event. Based on these accident scenarios in a large and unventilated process room, the modeling calculations of the hydrogen migration were performed to estimate local transient concentrations of hydrogen due to the sudden leakage and release from a glovebox system associated with the process tank. The modeling domain represented the major features of the process room including the principal release or leakage source of gas storage system. The model was benchmarked against the literature results for key phenomena such as natural convection, turbulent behavior, gas mixing due to jet entrainment, and radiation cooling because these phenomena are closely related to the gas driving mechanisms within a large air space of the process room. The modeling results showed that at the corner of the process room, the gas concentrations migrated by the Case 2 and Case 3 scenarios reached the set-point value of high activity alarm in about 13 seconds, while the Case 1 scenario takes about 90 seconds to reach the concentration. The modeling results were used to estimate transient radioactive gas migrations in an enclosed process room installed with high activity alarm monitor when the postulated leakage scenarios are initiated without room ventilation.

  13. Concatenation of 'alert' and 'identity' segments in dingoes' alarm calls.

    PubMed

    Déaux, Eloïse C; Allen, Andrew P; Clarke, Jennifer A; Charrier, Isabelle

    2016-07-27

    Multicomponent signals can be formed by the uninterrupted concatenation of multiple call types. One such signal is found in dingoes, Canis familiaris dingo. This stereotyped, multicomponent 'bark-howl' vocalisation is formed by the concatenation of a noisy bark segment and a tonal howl segment. Both segments are structurally similar to bark and howl vocalisations produced independently in other contexts (e.g. intra- and inter-pack communication). Bark-howls are mainly uttered in response to human presence and were hypothesized to serve as alarm calls. We investigated the function of bark-howls and the respective roles of the bark and howl segments. We found that dingoes could discriminate between familiar and unfamiliar howl segments, after having only heard familiar howl vocalisations (i.e. different calls). We propose that howl segments could function as 'identity signals' and allow receivers to modulate their responses according to the caller's characteristics. The bark segment increased receivers' attention levels, providing support for earlier observational claims that barks have an 'alerting' function. Lastly, dingoes were more likely to display vigilance behaviours upon hearing bark-howl vocalisations, lending support to the alarm function hypothesis. Canid vocalisations, such as the dingo bark-howl, may provide a model system to investigate the selective pressures shaping complex communication systems.

  14. On Alarm Protocol in Wireless Sensor Networks

    NASA Astrophysics Data System (ADS)

    Cichoń, Jacek; Kapelko, Rafał; Lemiesz, Jakub; Zawada, Marcin

    We consider the problem of efficient alarm protocol for ad-hoc radio networks consisting of devices that try to gain access for transmission through a shared radio communication channel. The problem arise in tasks that sensors have to quickly inform the target user about an alert situation such as presence of fire, dangerous radiation, seismic vibrations, and more. In this paper, we present a protocol which uses O(logn) time slots and show that Ω(logn/loglogn) is a lower bound for used time slots.

  15. Integrated Process Monitoring based on Systems of Sensors for Enhanced Nuclear Safeguards Sensitivity and Robustness

    SciTech Connect

    Humberto E. Garcia

    2014-07-01

    This paper illustrates safeguards benefits that process monitoring (PM) can have as a diversion deterrent and as a complementary safeguards measure to nuclear material accountancy (NMA). In order to infer the possible existence of proliferation-driven activities, the objective of NMA-based methods is often to statistically evaluate materials unaccounted for (MUF) computed by solving a given mass balance equation related to a material balance area (MBA) at every material balance period (MBP), a particular objective for a PM-based approach may be to statistically infer and evaluate anomalies unaccounted for (AUF) that may have occurred within a MBP. Although possibly being indicative of proliferation-driven activities, the detection and tracking of anomaly patterns is not trivial because some executed events may be unobservable or unreliably observed as others. The proposed similarity between NMA- and PM-based approaches is important as performance metrics utilized for evaluating NMA-based methods, such as detection probability (DP) and false alarm probability (FAP), can also be applied for assessing PM-based safeguards solutions. To this end, AUF count estimates can be translated into significant quantity (SQ) equivalents that may have been diverted within a given MBP. A diversion alarm is reported if this mass estimate is greater than or equal to the selected value for alarm level (AL), appropriately chosen to optimize DP and FAP based on the particular characteristics of the monitored MBA, the sensors utilized, and the data processing method employed for integrating and analyzing collected measurements. To illustrate the application of the proposed PM approach, a protracted diversion of Pu in a waste stream was selected based on incomplete fuel dissolution in a dissolver unit operation, as this diversion scenario is considered to be problematic for detection using NMA-based methods alone. Results demonstrate benefits of conducting PM under a system

  16. Hybrid systems process mixed wastes

    SciTech Connect

    Chertow, M.R.

    1989-10-01

    Some technologies, developed recently in Europe, combine several processes to separate and reuse materials from solid waste. These plants have in common, generally, that they are reasonably small, have a composting component for the organic portion, and often have a refuse-derived fuel component for combustible waste. Many European communities also have very effective drop-off center programs for recyclables such as bottles and cans. By maintaining the integrity of several different fractions of the waste, there is a less to landfill and less to burn. The importance of these hybrid systems is that they introduce in one plant an approach that encompasses the key concept of today's solid waste planning; recover as much as possible and landfill as little as possible. The plants also introduce various risks, particularly of finding secure markets. There are a number of companies offering various combinations of materials recovery, composting, and waste combustion. Four examples are included: multiple materials recovery and refuse-derived fuel production in Eden Prairie, Minnesota; multiple materials recovery, composting and refuse-derived fuel production in Perugia, Italy; composting, refuse-derived fuel, and gasification in Tolmezzo, Italy; and a front-end system on a mass burning waste-to-energy plant in Neuchatel, Switzerland.

  17. Optimal Sensor Location Design for Reliable Fault Detection in Presence of False Alarms

    PubMed Central

    Yang, Fan; Xiao, Deyun; Shah, Sirish L.

    2009-01-01

    To improve fault detection reliability, sensor location should be designed according to an optimization criterion with constraints imposed by issues of detectability and identifiability. Reliability requires the minimization of undetectability and false alarm probability due to random factors on sensor readings, which is not only related with sensor readings but also affected by fault propagation. This paper introduces the reliability criteria expression based on the missed/false alarm probability of each sensor and system topology or connectivity derived from the directed graph. The algorithm for the optimization problem is presented as a heuristic procedure. Finally, a boiler system is illustrated using the proposed method. PMID:22291524

  18. False alarm reduction during landmine detection

    NASA Astrophysics Data System (ADS)

    Prado, P. J.; Chongpison, A.; Doraisamy, L.

    2007-04-01

    Quadrupole Resonance sensors have the unique capability of detecting explosives from buried, plastic-cased antipersonnel and antitank landmines. The chemical specificity of this radio-frequency technique provides the potential to deliver remarkably low false alarm rates during landmine detection. This is of particular importance to deminers, who frequently come across numerous clutter items before uncovering a mine. Quadrupole Resonance is typically utilized in a confirmation mode; preceded by rapid primary scans carried out by, for example, metal detectors, ground penetrating radars or a fusion of these. Significant technical and scientific advances have resulted in the fabrication of handheld and vehicle mounted Quadrupole Resonance landmine detectors in compact, power-efficient configurations. The development work is focused on baseline sensitivity increase, as well as the achievement of high detection performance under field conditions. The mine detection capability of Quadrupole Resonance detectors has been evaluated during various blind tests. A modular handheld unit, combining primary and confirmation sensors, was designed to be operated by a single person. A series of field tests demonstrate the unique capability of Quadrupole Resonance for significant false alarm reduction.

  19. EMAT weld inspection and weld machine diagnostic system for continuous coil processing lines

    NASA Astrophysics Data System (ADS)

    Latham, Wayne M.; MacLauchlan, Daniel T.; Geier, Dan P.; Lang, Dennis D.

    1996-11-01

    Weld breaks of steel coil during cold rolling and continuous pickling operations are a significant source of lost productivity and product yield. Babcock and Wilcox Innerspec Technologies has developed a weld process control system which monitors the key variables of the welding process and determines the quality of the welds generated by flash butt welding equipment. This system is known as the Temate 2000 Automated Flash Butt Weld Inspection and Weld Machine Diagnostic System. The Temate 2000 system utilizes electro- magnetic acoustic transducer (EMAT) technology as the basis for performing on-line, real-time, nondestructive weld quality evaluation. This technique accurately detects voids, laps, misalignment and over/under trim conditions in the weld. Results of the EMAT weld inspection are immediately presented to the weld machine operator for disposition. Welding process variables such as voltage, current, platen movements and upset pressures are monitored and collected with the high speed data acquisition system. This data is processed and presented in real-time display to indicate useful welding process information such as platen crabbing, upset force, peak upset current, and many others. Alarming for each variable is provided and allows detailed maintenance reports and summary information to be generated. All weld quality and process parameter data are stored, traceable to each unique weld, and available for post process evaluation. Installation of the Temate 2000 system in a major flat rolled steel mill has contributed to near elimination of weld breakage and increased productivity at this facility.

  20. [The alarming increase of incapacity for work].

    PubMed

    Thibaut, P

    2013-09-01

    The alarming increase of incapacity for work The increase of incapacity for work in Belgium and in Europe is not a new phenomenon but only the transposition of an experience already lived on others continents (Canada--USA). The bio-psycho-social model proves to be, on the international level, as the more efficient view for the understanding of the mechanisms production of the disability and therefore of the incapacity for work. Following this approach, the chronic pain is the result of the dynamic interaction between physiological, psychological and social factors. It mentions also an existing link between the pain and the depression itself being a determining factor in the persistence of the incapacity for work. The bio-psycho-social model can only be conceived in the interdisciplinary approach, and will for sure allow to optimize the support and the use of medicines with a painkiller and depressive aim. The socio-economic impact created represents actually a real health problem.

  1. Modeling Kanban Processes in Systems Engineering

    DTIC Science & Technology

    2012-06-01

    Modeling Kanban Processes in Systems Engineering Richard Turner School of Systems and Enterprises Stevens Institute of Technology Hoboken, NJ...dingold@usc.edu, jolane@usc.edu Abstract—Systems engineering processes using pull scheduling methods ( kanban ) are being evaluated with hybrid...development projects incrementally evolve capabilities of existing systems and/or systems of systems. A kanban -based scheduling system was defined and

  2. Lifelong opioidergic vulnerability through early life separation: a recent extension of the false suffocation alarm theory of panic disorder.

    PubMed

    Preter, Maurice; Klein, Donald F

    2014-10-01

    The present paper is the edited version of our presentations at the "First World Symposium On Translational Models Of Panic Disorder", in Vitoria, E.S., Brazil, on November 16-18, 2012. We also review relevant work that appeared after the conference. Suffocation-False Alarm Theory (Klein, 1993) postulates the existence of an evolved physiologic suffocation alarm system that monitors information about potential suffocation. Panic attacks maladaptively occur when the alarm is erroneously triggered. The expanded Suffocation-False Alarm Theory (Preter and Klein, 2008) hypothesizes that endogenous opioidergic dysregulation may underlie the respiratory pathophysiology and suffocation sensitivity in panic disorder. Opioidergic dysregulation increases sensitivity to CO2, separation distress and panic attacks. That sudden loss, bereavement and childhood separation anxiety are also antecedents of "spontaneous" panic requires an integrative explanation. Our work unveiling the lifelong endogenous opioid system impairing effects of childhood parental loss (CPL) and parental separation in non-ill, normal adults opens a new experimental, investigatory area.

  3. Social network supported process recommender system.

    PubMed

    Ye, Yanming; Yin, Jianwei; Xu, Yueshen

    2014-01-01

    Process recommendation technologies have gained more and more attention in the field of intelligent business process modeling to assist the process modeling. However, most of the existing technologies only use the process structure analysis and do not take the social features of processes into account, while the process modeling is complex and comprehensive in most situations. This paper studies the feasibility of social network research technologies on process recommendation and builds a social network system of processes based on the features similarities. Then, three process matching degree measurements are presented and the system implementation is discussed subsequently. Finally, experimental evaluations and future works are introduced.

  4. NASA System Engineering Design Process

    NASA Technical Reports Server (NTRS)

    Roman, Jose

    2011-01-01

    This slide presentation reviews NASA's use of systems engineering for the complete life cycle of a project. Systems engineering is a methodical, disciplined approach for the design, realization, technical management, operations, and retirement of a system. Each phase of a NASA project is terminated with a Key decision point (KDP), which is supported by major reviews.

  5. Intrathoracic impedance monitor alarm in a patient with cardiac resynchronisation therapy and advanced lung carcinoma.

    PubMed

    Cvijić, Marta; Zižek, David; Antolič, Bor; Zupan, Igor

    2013-01-01

    The intrathoracic impedance monitor system measures impedance between the device case and the right ventricular coil and reflects intrathoracic fluid status. It is used to detect early volume overload in patients with chronic heart failure. We report a case of inappropriate activation of the intrathoracic impedance monitor alarm in a patient with epidermoid lung cancer and pleural carcinosis.

  6. False alarm recognition in hyperspectral gas plume identification

    SciTech Connect

    Conger, James L.; Lawson, Janice K.; Aimonetti, William D.

    2011-03-29

    According to one embodiment, a method for analyzing hyperspectral data includes collecting first hyperspectral data of a scene using a hyperspectral imager during a no-gas period and analyzing the first hyperspectral data using one or more gas plume detection logics. The gas plume detection logic is executed using a low detection threshold, and detects each occurrence of an observed hyperspectral signature. The method also includes generating a histogram for all occurrences of each observed hyperspectral signature which is detected using the gas plume detection logic, and determining a probability of false alarm (PFA) for all occurrences of each observed hyperspectral signature based on the histogram. Possibly at some other time, the method includes collecting second hyperspectral data, and analyzing the second hyperspectral data using the one or more gas plume detection logics and the PFA to determine if any gas is present. Other systems and methods are also included.

  7. [Citalopram, escitalopram and prolonged QT: warning or alarm?].

    PubMed

    Alvarez, Enric; Vieira, Sara; Garcia-Moll, Xavier

    2014-01-01

    The alerts issued by regulatory agencies on the potential cardiac toxicity of citalopram and escitalopram have caused alarm among clinicians. A review of the data concerning this topic shows that the alarm should be limited to patients with a history of syncope or poisoning. As a precautionary measure, an electrocardiogram should be performed on elderly patients.

  8. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  9. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  10. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  11. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  12. 47 CFR 80.318 - Use of alarm signals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Use of alarm signals. 80.318 Section 80.318 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress, Alarm, Urgency and Safety...

  13. Successful Use of the Nocturnal Urine Alarm for Diurnal Enuresis.

    ERIC Educational Resources Information Center

    Friman, Patrick C.; Vollmer, Dennis

    1995-01-01

    A urine alarm, typically used to treat nocturnal enuresis, was effectively used to treat diurnal enuresis in a 15-year-old female with depression, attention deficit hyperactivity disorder, and conduct disorder. The study indicated that the alarm eliminated wetting in both treatment phases and that continence was maintained at three-month and…

  14. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  15. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  16. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  17. 33 CFR 401.17 - Pitch indicators and alarms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Pitch indicators and alarms. 401... indicators and alarms. Every vessel of 1600 gross registered tons or integrated tug and barge or articulated... propeller shall be equipped with— (a) A pitch indicator in the wheelhouse and the engine room; and...

  18. 33 CFR 157.440 - Autopilot alarm or indicator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Autopilot alarm or indicator. 157.440 Section 157.440 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... § 157.440 Autopilot alarm or indicator. (a) A tankship owner or operator shall ensure that...

  19. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  20. 46 CFR 131.805 - General alarm bell, switch.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false General alarm bell, switch. 131.805 Section 131.805 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.805 General alarm bell, switch. The switch in...

  1. 33 CFR 157.440 - Autopilot alarm or indicator.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Autopilot alarm or indicator. 157.440 Section 157.440 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... § 157.440 Autopilot alarm or indicator. (a) A tankship owner or operator shall ensure that...

  2. 33 CFR 401.17 - Pitch indicators and alarms.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Pitch indicators and alarms. 401... indicators and alarms. Every vessel of 1600 gross registered tons or integrated tug and barge or articulated... propeller shall be equipped with— (a) A pitch indicator in the wheelhouse and the engine room; and...

  3. 1. Photographic copy of fire alarm plan for Control and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photographic copy of fire alarm plan for Control and Recording Center Building 4221/E-22, showing layout of rooms. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Edwards Test Station, Fire Alarm Plan, Bldg. E-22,' drawing no. EFA/11-1, December 15, 1961. - Jet Propulsion Laboratory Edwards Facility, Control & Recording Center, Edwards Air Force Base, Boron, Kern County, CA

  4. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  5. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  6. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  7. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  8. 46 CFR 28.250 - High water alarms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false High water alarms. 28.250 Section 28.250 Shipping COAST... Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade § 28.250 High water alarms. On... operating station to indicate high water level in each of the following normally unmanned spaces: (a)...

  9. ESS Cryogenic System Process Design

    NASA Astrophysics Data System (ADS)

    Arnold, P.; Hees, W.; Jurns, J.; Su, X. T.; Wang, X. L.; Weisend, J. G., II

    2015-12-01

    The European Spallation Source (ESS) is a neutron-scattering facility funded and supported in collaboration with 17 European countries in Lund, Sweden. Cryogenic cooling at ESS is vital particularly for the linear accelerator, the hydrogen target moderators, a test stand for cryomodules, the neutron instruments and their sample environments. The paper will focus on specific process design criteria, design decisions and their motivations for the helium cryoplants and auxiliary equipment. Key issues for all plants and their process concepts are energy efficiency, reliability, smooth turn-down behaviour and flexibility. The accelerator cryoplant (ACCP) and the target moderator cryoplant (TMCP) in particular need to be prepared for a range of refrigeration capacities due to the intrinsic uncertainties regarding heat load definitions. Furthermore the paper addresses questions regarding process arrangement, 2 K cooling methodology, LN2 precooling, helium storage, helium purification and heat recovery.

  10. Vision Systems Illuminate Industrial Processes

    NASA Technical Reports Server (NTRS)

    2013-01-01

    When NASA designs a spacecraft to undertake a new mission, innovation does not stop after the design phase. In many cases, these spacecraft are firsts of their kind, requiring not only remarkable imagination and expertise in their conception but new technologies and methods for their manufacture. In the realm of manufacturing, NASA has from necessity worked on the cutting-edge, seeking new techniques and materials for creating unprecedented structures, as well as capabilities for reducing the cost and increasing the efficiency of existing manufacturing technologies. From friction stir welding enhancements (Spinoff 2009) to thermoset composites (Spinoff 2011), NASA s innovations in manufacturing have often transferred to the public in ways that enable the expansion of the Nation s industrial productivity. NASA has long pursued ways of improving upon and ensuring quality results from manufacturing processes ranging from arc welding to thermal coating applications. But many of these processes generate blinding light (hence the need for special eyewear during welding) that obscures the process while it is happening, making it difficult to monitor and evaluate. In the 1980s, NASA partnered with a company to develop technology to address this issue. Today, that collaboration has spawned multiple commercial products that not only support effective manufacturing for private industry but also may support NASA in the use of an exciting, rapidly growing field of manufacturing ideal for long-duration space missions.

  11. Soldier Integrated Headwear System: System Design Process

    DTIC Science & Technology

    2006-10-01

    Nationale Canada Abstract The aim of the Soldier Integrated Headwear System –Technology Demonstration Project (SIHS-TDP) is to empirically...determine the most promising headwear integration concept that significantly enhances the survivability and effectiveness of the future Canadian

  12. The standards process: X3 information processing systems

    NASA Technical Reports Server (NTRS)

    Emard, Jean-Paul

    1993-01-01

    The topics are presented in viewgraph form and include the following: International Organization for Standards (ISO); International Electrotechnical Committee (IEC); ISO/IEC Joint Technical Committee 1 (JTC-1); U.S. interface to JTC-1; ANSI; national organizations; U.S. standards development processes; national and international standards developing organizations; regional organizations; and X3 information processing systems.

  13. Design of penicillin fermentation process simulation system

    NASA Astrophysics Data System (ADS)

    Qi, Xiaoyu; Yuan, Zhonghu; Qi, Xiaoxuan; Zhang, Wenqi

    2011-10-01

    Real-time monitoring for batch process attracts increasing attention. It can ensure safety and provide products with consistent quality. The design of simulation system of batch process fault diagnosis is of great significance. In this paper, penicillin fermentation, a typical non-linear, dynamic, multi-stage batch production process, is taken as the research object. A visual human-machine interactive simulation software system based on Windows operation system is developed. The simulation system can provide an effective platform for the research of batch process fault diagnosis.

  14. Information Processing in Living Systems

    NASA Astrophysics Data System (ADS)

    Tkačik, Gašper; Bialek, William

    2016-03-01

    Life depends as much on the flow of information as on the flow of energy. Here we review the many efforts to make this intuition precise. Starting with the building blocks of information theory, we explore examples where it has been possible to measure, directly, the flow of information in biological networks, or more generally where information-theoretic ideas have been used to guide the analysis of experiments. Systems of interest range from single molecules (the sequence diversity in families of proteins) to groups of organisms (the distribution of velocities in flocks of birds), and all scales in between. Many of these analyses are motivated by the idea that biological systems may have evolved to optimize the gathering and representation of information, and we review the experimental evidence for this optimization, again across a wide range of scales.

  15. Propellant injection systems and processes

    NASA Technical Reports Server (NTRS)

    Ito, Jackson I.

    1995-01-01

    The previous 'Art of Injector Design' is maturing and merging with the more systematic 'Science of Combustion Device Analysis.' This technology can be based upon observation, correlation, experimentation and ultimately analytical modeling based upon basic engineering principles. This methodology is more systematic and far superior to the historical injector design process of 'Trial and Error' or blindly 'Copying Past Successes.' The benefit of such an approach is to be able to rank candidate design concepts for relative probability of success or technical risk in all the important combustion device design requirements and combustion process development risk categories before committing to an engine development program. Even if a single analytical design concept cannot be developed to predict satisfying all requirements simultaneously, a series of risk mitigation key enabling technologies can be identified for early resolution. Lower cost subscale or laboratory experimentation to demonstrate proof of principle, critical instrumentation requirements, and design discriminating test plans can be developed based on the physical insight provided by these analyses.

  16. Process for making a multilayer interconnect system

    NASA Technical Reports Server (NTRS)

    Zachry, Clyde L. (Inventor); Niedzwiecke, Andrew J. (Inventor)

    1976-01-01

    A process for making an interconnect system for a multilayer circuit pattern. The interconnect system is formed having minimized through-hole space consumption so as to be suitable for high density, closely meshed circuit patterns.

  17. Collection and evaluation of false alarm signatures in background data

    NASA Astrophysics Data System (ADS)

    Agarwal, Sanjeev; Vulli, Shivakar; Malloy, Neil J.; Lord, Elizabeth M.; Fairley, Josh R.; Sabol, Bruce M.; Johnson, Wesley; Ess, Richard; Trang, Anh H.

    2009-05-01

    A significant amount of background airborne data was collected as part of May 2005 tests for airborne minefield detection at an arid site. The locations of false alarms which occurred consistently during different runs, were identified and geo-referenced by MultiSensor Science LLC. Ground truth information, which included pictures, type qualifiers and some hyperspectral data for these identified false alarm locations, was surveyed by ERDC-WES. This collection of background data, and subsequent survey of the false alarm locations, is unique in that it is likely the first such airborne data collection with ground truthed and documented false alarm locations. A library of signatures for different sources of these false alarms was extracted in the form of image chips and organized into a self-contained database by Missouri S&T. The library contains target chips from airborne mid wave infrared (MWIR) and multispectral imaging (MSI) sensors, representing data for different days, different times of day and different altitudes. Target chips for different surface mines were also added to the database. This database of the target signatures is expected to facilitate evaluation of spectral and shape characteristics of the false alarms, to achieve better false alarm mitigation and improve mine and minefield detection for airborne applications. The aim of this paper is to review and summarize the data collection procedure used, present the currently available database of target chips and make some recommendations regarding future data collections.

  18. RDD-100 and the systems engineering process

    NASA Technical Reports Server (NTRS)

    Averill, Robert D.

    1994-01-01

    An effective systems engineering approach applied through the project life cycle can help Langley produce a better product. This paper demonstrates how an enhanced systems engineering process for in-house flight projects assures that each system will achieve its goals with quality performance and within planned budgets and schedules. This paper also describes how the systems engineering process can be used in combination with available software tools.

  19. Improving Process Heating System Performance v3

    SciTech Connect

    2016-04-11

    Improving Process Heating System Performance: A Sourcebook for Industry is a development of the U.S. Department of Energy (DOE) Advanced Manufacturing Office (AMO) and the Industrial Heating Equipment Association (IHEA). The AMO and IHEA undertook this project as part of an series of sourcebook publications developed by AMO on energy-consuming industrial systems, and opportunities to improve performance. Other topics in this series include compressed air systems, pumping systems, fan systems, steam systems, and motors and drives

  20. Information Processing Capacity of Dynamical Systems

    PubMed Central

    Dambre, Joni; Verstraeten, David; Schrauwen, Benjamin; Massar, Serge

    2012-01-01

    Many dynamical systems, both natural and artificial, are stimulated by time dependent external signals, somehow processing the information contained therein. We demonstrate how to quantify the different modes in which information can be processed by such systems and combine them to define the computational capacity of a dynamical system. This is bounded by the number of linearly independent state variables of the dynamical system, equaling it if the system obeys the fading memory condition. It can be interpreted as the total number of linearly independent functions of its stimuli the system can compute. Our theory combines concepts from machine learning (reservoir computing), system modeling, stochastic processes, and functional analysis. We illustrate our theory by numerical simulations for the logistic map, a recurrent neural network, and a two-dimensional reaction diffusion system, uncovering universal trade-offs between the non-linearity of the computation and the system's short-term memory. PMID:22816038